WorldWideScience

Sample records for acid dew point

  1. Acid dew point measurement in flue gases

    Energy Technology Data Exchange (ETDEWEB)

    Struschka, M.; Baumbach, G.

    1986-06-01

    The operation of modern boiler plants requires the continuous measurement of the acid dew point in flue gases. An existing measuring instrument was modified in such a way that it can determine acid dew points reliably, reproduceably and continuously. The authors present the mechanisms of the dew point formation, the dew point measuring principle, the modification and the operational results.

  2. Predicting acid dew point with a semi-empirical model

    International Nuclear Information System (INIS)

    Xiang, Baixiang; Tang, Bin; Wu, Yuxin; Yang, Hairui; Zhang, Man; Lu, Junfu

    2016-01-01

    Highlights: • The previous semi-empirical models are systematically studied. • An improved thermodynamic correlation is derived. • A semi-empirical prediction model is proposed. • The proposed semi-empirical model is validated. - Abstract: Decreasing the temperature of exhaust flue gas in boilers is one of the most effective ways to further improve the thermal efficiency, electrostatic precipitator efficiency and to decrease the water consumption of desulfurization tower, while, when this temperature is below the acid dew point, the fouling and corrosion will occur on the heating surfaces in the second pass of boilers. So, the knowledge on accurately predicting the acid dew point is essential. By investigating the previous models on acid dew point prediction, an improved thermodynamic correlation formula between the acid dew point and its influencing factors is derived first. And then, a semi-empirical prediction model is proposed, which is validated with the data both in field test and experiment, and comparing with the previous models.

  3. Experimental study of influence characteristics of flue gas fly ash on acid dew point

    Science.gov (United States)

    Song, Jinhui; Li, Jiahu; Wang, Shuai; Yuan, Hui; Ren, Zhongqiang

    2017-12-01

    The long-term operation experience of a large number of utility boilers shows that the measured value of acid dew point is generally lower than estimated value. This is because the influence of CaO and MgO on acid dew point in flue gas fly ash is not considered in the estimation formula of acid dew point. On the basis of previous studies, the experimental device for acid dew point measurement was designed and constructed, and the acid dew point under different smoke conditions was measured. The results show that the CaO and MgO in the flue gas fly ash have an obvious influence on the acid dew point, and the content of the fly ash is negatively correlated with the temperature of acid dew point At the same time, the concentration of H2SO4 in flue gas is different, and the acid dew point of flue gas is different, and positively correlated with the acid dew point.

  4. Theory of acid deposition and its application to the dew-point meter

    Energy Technology Data Exchange (ETDEWEB)

    Land, T.

    1977-06-01

    The theory of convective mass transfer is used to calculate the rate of deposition of sulphuric acid on cooled surfaces in boiler flues. The mass deposited per unit area per second is ah/c (p/sub Ag/ - p/sub As/) where h is the coefficient of convective heat transfer, c is the specific heat of the gas and a is a factor having a value of about 1.9; p/sub Ag/ and p/sub As/ are the partial pressures of sulphuric acid in the bulk of the gas and in saturated gas at the temperature of the surface. Values of p/sub A/ are tabulated against dew-point temperature and water vapour content. The theory explains how fog formation in the gas reduces the rate of acid deposition within a certain band of temperature between the acid dew-point and the water dew-point. The rate of deposition on a probe is shown to depend on the local mass flow as well as on the acid content. By contrast the dew-point depends only on the acid content. The sensitivity of the dew-point meter to changes in acid content is not very high but it is adequate for the control of combustion. A continuously recording dew-point meter is being successfully used on industrial boilers.

  5. Continuous acid dew point measurement in coal-fired power plants; Kontinuierliche Saeuretaupunktmessung in Braunkohlekraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Foedisch, Holger; Schulz, Joerg; Schengber, Petra; Dietrich, Gabriele [Dr. Foedisch Umweltmesstechnik AG, Markranstaedt (Germany)

    2009-07-01

    The reduction of flue gas losses is one option to increase power plant efficiency. The target is the optimised low waste gas temperature. When applying lignite and other high-sulphur fuels the temperature of the flue gas is mainly determined by the acid dew point. Temperature of the flue gas system is to amount some 10 to 20 K above the assumed acid dew point. The acid dew point measuring system AMD 08 is able to detect the real acid dew point in a quasi-continuous way. Thus, it is possible to deliberately decrease waste gas temperature. (orig.)

  6. Concerning the acid dew point in waste gases from combustion processes

    Energy Technology Data Exchange (ETDEWEB)

    Knoche, K.F.; Deutz, W.; Hein, K.; Derichs, W.

    1986-09-01

    The paper discusses the problems associated with the measurement of acid dew point and of sulphuric acid-(say SO/sub 3/-)concentrations in the flue gas from brown coal-fired boiler plants. The sulphuric acid content in brown coal flue gas has been measured at 0.5 to 3 vpm in SO/sub 2/ concentrations of 200 to 800 vpm. Using a conditional equation, the derivation of which from new formulae for phase stability is described in the paper, an acid dew point temperature of 115 to 125/sup 0/C is produced.

  7. Estimation of combustion flue gas acid dew point during heat recovery and efficiency gain

    Energy Technology Data Exchange (ETDEWEB)

    Bahadori, A. [Curtin University of Technology, Perth, WA (Australia)

    2011-06-15

    When cooling combustion flue gas for heat recovery and efficiency gain, the temperature must not be allowed to drop below the sulfur trioxide dew point. Below the SO{sub 3} dew point, very corrosive sulfuric acid forms and leads to operational hazards on metal surfaces. In the present work, simple-to-use predictive tool, which is easier than existing approaches, less complicated with fewer computations is formulated to arrive at an appropriate estimation of acid dew point during combustion flue gas cooling which depends on fuel type, sulfur content in fuel, and excess air levels. The resulting information can then be applied to estimate the acid dew point, for sulfur in various fuels up to 0.10 volume fraction in gas (0.10 mass fraction in liquid), excess air fractions up to 0.25, and elemental concentrations of carbon up to 3. The proposed predictive tool shows a very good agreement with the reported data wherein the average absolute deviation percent was found to be around 3.18%. This approach can be of immense practical value for engineers and scientists for a quick estimation of acid dew point during combustion flue gas cooling for heat recovery and efficiency gain for wide range of operating conditions without the necessity of any pilot plant setup and tedious experimental trials. In particular, process and combustion engineers would find the tool to be user friendly involving transparent calculations with no complex expressions for their applications.

  8. Acid dew point measurements in combustion gases using the dew point measuring system AH 85100

    Energy Technology Data Exchange (ETDEWEB)

    Fehler, D.

    1984-01-01

    Measuring system for continuous monitoring of the SO/sub 2//SO/sub 3/ dew point in the flue gas, characterized by a low failure rate, applicability inside the flue gas duct, maintenance-free continuous operation, and self-cleaning. The measuring principle is the cooling of the sensor element down to the 'onset condensation' message. Sensor surface temperatures are listed and evaluated as flue gas dew point temperatures. The measuring system is described. (DOMA).

  9. Laser Dew-Point Hygrometer

    Science.gov (United States)

    Matsumoto, Shigeaki; Toyooka, Satoru

    1995-01-01

    A rough-surface-type automatic dew-point hygrometer was developed using a laser diode and an optical fiber cable. A gold plate with 0.8 µ m average surface roughness was used as a surface for deposition of dew to facilitate dew deposition and prevent supersaturation of water vapor at the dew point. It was shown experimentally that the quantity of dew deposited can be controlled to be constant at any predetermined level, and is independent of the dew point to be measured. The dew points were measured in the range from -15° C to 54° C in which the temperature ranged from 0° C to 60° C. The measurement error of the dew point was ±0.5° C which was equal to below ±2% in relative humidity in the above dew-point range.

  10. Dew point of gases with low sulfuric acid content

    Energy Technology Data Exchange (ETDEWEB)

    Fieg, J.

    1981-07-01

    Discusses control of air pollution caused by sulfur compounds in solid fuels during combustion. Excessive amount of oxygen during combustion leads to formation of sulfur trioxide. Sulfur trioxide reacts with water vapor and forms sulfuric acid. Chemical reactions which lead to formation of sulfuric acid are described. Conditions for sulfuric acid condensation are analyzed. Several methods for determining dew point of flue gases with low sulfuric acid content are reviewed: methods based on determination of electric conductivity of condensed sulfuric acid (Francis, Cheney, Kiyoure), method based on determination of sulfuric acid concentration in the gaseous phase and in the liquid phase after cooling (Lee, Lisle and Sensenbaugh, Ross and Goksoyr). (26 refs.) (In Polish)

  11. Contribution to the study of sulfur trioxide formation and determination of the sulfuric acid dew point in boiler plants

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, H.

    1983-11-01

    This paper analyzes chemical reaction kinetics of the formation of sulfur trioxide and sulfuric acid in combustion air and flue gas of steam generators. Formulae for sulfuric acid equilibrium reactions according to Wahnschaffe (W. Grimm, 1972) and R. Hasse, H.W. Borgmann (1962) are presented. Theoretical acid dew point, combustion parameters with influence on the dew point temperature and formation of sulfates are further discussed. Sulfur trioxide formation at temperatures above 1,000 C as a non-equilibrium reaction is outlined as another variant of chemical reactions. A graphic evaluation is made of dew point conditions in brown coal dust fired, and heating oil fired steam generators. (11 refs.)

  12. Technical aspects of acid dew point measurement in furnace exhaust. Messtechnik fuer die Saeuretaupunktmessung in Feuerungsabgasen

    Energy Technology Data Exchange (ETDEWEB)

    Struschka, M.; Baumbach, G.

    1986-01-01

    SO/sub 3/ formation in flue gases and the effect of furnace parameters, furnace type and design on the efficiency of SO/sub 2/ conversion were investigated in a detailed bibliographic study. Phase equilibrium data for the binary system H/sub 2/SO/sub 4//H/sub 2/O and equations for calculating the acid dew point are presented, and the available wet chemical methods for SO/sub 3/ concentration measurements in flue gases are reviewed. The SM1 acid dew point measuring instrument availabe at the authors' institute was modified by installing a new measuring probe, an external thermoelement intensifier, and a new PD control element for temperature control in the measuring surfaces. Acid dew point measurements were carried out in two different furnaces, i.e. a domestic boiler for light fuel oil and an industrial furnace fuelled with heavy oil at the Stuttgart University heat- and power plant. The measurements are compared with data from relevant publications. (orig./RB) With 80 figs., 7 tabs.

  13. Automated and continuously operating acid dew point measuring instrument for flue gases

    Energy Technology Data Exchange (ETDEWEB)

    Reckmann, D.; Naundorf, G.

    1986-06-01

    Design and operation is explained for a sulfuric acid dew point indicator for continuous flue gas temperature control. The indicator operated successfully in trial tests over several years with brown coal, gas and oil combustion in a measurement range of 60 to 180 C. The design is regarded as uncomplicated and easy to manufacture. Its operating principle is based on electric conductivity measurement on a surface on which sulfuric acid vapor has condensed. A ring electrode and a PtRh/Pt thermal element as central electrode are employed. A scheme of the equipment design is provided. Accuracy of the indicator was compared to manual dew point sondes manufactured by Degussa and showed a maximum deviation of 5 C. Manual cleaning after a number of weeks of operation is required. Fly ash with a high lime content increases dust buildup and requires more frequent cleaning cycles.

  14. Calculating the flue gas dew point for raw brown coal fired steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Schinkel, W.

    1977-01-01

    The paper analyzes parameters influencing the sulfuric acid dew point in flue gas of steam generators. Sulfur content and alkaline earths content in the fuel air ratio during combustion, fly ash content in the flue gas (which absorbs sulfur dioxide and sulfur trioxide) and combustion conditions in steam generators are relevant parameters in the combustion process. A thermodynamic and reaction kinetic calculation of the sulfuric acid dew point is, however, not yet possible. A statistical evaluation of dew point measurements in steam generators is, therefore, employed. Various diagrams show results of dew point measurements carried out at generators with steam capacities ranging from 40 to 660 t/h, which demonstrate relations of these parameters to flue gas dew points, in particular the relative sulfur content (sulfur content in the raw brown coal compared to coal ash content and alkaline earths content). A function is derived for the conversion of fuel sulfur to sulfur trioxide. A diagram presents the relation of the flue gas dew point to partial pressures of sulfuric acid and steam. Direct calculation of the flue gas dew point was achieved by the proposed method. It is applied in steam generator design. (17 refs.)

  15. Mechanism research on coupling effect between dew point corrosion and ash deposition

    International Nuclear Information System (INIS)

    Wang, Yun-Gang; Zhao, Qin-Xin; Zhang, Zhi-Xiang; Zhang, Zhi-Chao; Tao, Wen-Quan

    2013-01-01

    In order to study the coupling mechanism between ash deposition and dew point corrosion, five kinds of tube materials frequently used as anti-dew point corrosion materials were selected as research objects. Dew point corrosion and ash deposition experiments were performed with a new type experimental device in a Chinese thermal power plant. The microstructures of the materials and the composition of ash deposition were analyzed by X-ray diffraction (XRD) and Energy Dispersive Spectrometer (EDS). The results showed that the ash deposition layer could be divided into non-condensation zone, the main condensation zone and the secondary condensation zone. The acid vapor condensed in the main condensation zone rather than directly on the tube wall surface. The dew point corrosion mainly is oxygen corrosion under the condition of the viscosity ash deposition, and the corrosion products are composed of the ash and acid reaction products in the outer layer, iron sulfate in the middle layer, and iron oxide in the inner layer. The innermost layer is the main corrosion layer. With the increase of the tube wall temperature, the ash deposition changes from the viscosity ash deposition to the dry loose ash deposition, the ash deposition rate decreases dramatically and dew point corrosion is alleviated efficiently. The sulfuric dew point corrosion resistance of the five test materials is as follows: 316L > ND > Corten>20G > 20 steel. -- Highlights: ► Dew point corrosion and ash deposition tests of five materials were performed. ► Acid vapor condensed in the ash deposit rather than directly on the tube surface. ► Dew point corrosion resistance is as follow: 316L > ND > Corten>20G > 20 steel. ► Dew point corrosion mainly is oxygen corrosion under viscosity ash deposition

  16. Dew point measurements of flue gases in steam generators with brown coal combustion

    Energy Technology Data Exchange (ETDEWEB)

    Schinkel, W.

    1980-01-01

    This paper examines empirical data on sulfuric acid condensation and resulting internal corrosion in brown coal fired steam generators. Due to the high sulfur content in brown coal (0.5% to 5.0%) and relative short duration of the gases in the combustion chamber the concentrations of sulfur trioxide present in the flue gases can condense at the heat exchange surfaces of the steam generators. A number of diagrams show sulfuric acid dew point temperatures depending on brown coal sulfur content, the influence of combustion air supply on the dew point, and condensing speed and the rate of corrosion in relation to different heat exchange surface temperatures. The conclusion is made that a five-fold increase in corrosion can be caused by a 10 K higher flue gas dew point, a 5 K cooling of heating surfaces can also cause heavy corrosion at a certain dew point. Maximum corrosion results at 20 to 50 K differences between flue gas dew point and heat exchange surfaces. Optimum operation of steam generators with minimal internal corrosion requires the consideration of flue gas and heating surface temperatures as well as flue gas sulfur acid dew points. (10 refs.) (In German)

  17. Dew point of flue gas in the combustion of brown coal briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Schinkel, W

    1977-08-01

    Economical operation of small steam generators can follow two courses, viz. to channel the emitted gases through the plant and reduce waste gas loss. Two possibilities exist to achieve this: firstly a steam generating process with only slight excess air; secondly a reduction of the emitted gas temperature. The lowest waste gas temperature found in sulphur-containing combustion materials is measured by finding the acid dew-point of the waste gas. The following results in the case of brown coal briquettes were found. Measurements of the dew point of flue gas in two steam generators, both of the double flue type, one having a capacity of 12.5 t/h, the other 25 t/h, one using brown coal briquettes with 1% sulphur content, the other with 3%, resulted in the fact that the dew point can be measured. It was shown that a low air ratio leads to a lowering of the dew point. However this process is unfortunately economically unviable in chain grate generators as the waste gas becomes so thin under a high air ratio that the dew point can only be minimally reduced. Further the acid dew point is only slightly influenced by partial operation of the generator and the infusion of briquette residue.

  18. A new steel with good low-temperature sulfuric acid dew point corrosion resistance

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, X.Q.; Li, X.G. [Corrosion and Protection Center, University of Science and Technology Beijing (China); Key Laboratory of Corrosion and Protection (Ministry of Education), Beijing (China); Sun, F.L. [Corrosion and Protection Center, University of Science and Technology Beijing (China); Lv, S.J. [Corrosion and Protection Center, University of Science and Technology Beijing (China); Equipment and Power Department, Shijiazhuang Refine and Chemical Company Limited, SINOPEC, Shijiazhuang (China)

    2012-07-15

    In this work, new steels (1, 2, and 3) were developed for low-temperature sulfuric acid dew point corrosion. The mass loss rate, macro- and micro-morphologies and compositions of corrosion products of new steels in 10, 30, and 50% H{sub 2}SO{sub 4} solutions at its corresponding dew points were investigated by immersion test, scanning electron microscopy (SEM) and energy-dispersive spectrometry (EDS). The results indicated that mass loss rate of all the tested steels first strongly increased and then decreased as H{sub 2}SO{sub 4} concentration increased, which reached maximum at 30%. Corrosion resistance of 2 steel is the best among all specimens due to its fine and homogeneous morphologies of corrosion products. The electrochemical corrosion properties of new steels in 10 and 30% H{sub 2}SO{sub 4} solutions at its corresponding dew points were studied by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The results demonstrated that corrosion resistance of 2 steel is the best among all the experimental samples due to its lowest corrosion current density and highest charge transfer resistance, which is consistent with the results obtained from immersion tests. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Dew Point

    OpenAIRE

    Goldsmith, Shelly

    1999-01-01

    Dew Point was a solo exhibition originating at PriceWaterhouseCoopers Headquarters Gallery, London, UK and toured to the Centre de Documentacio i Museu Textil, Terrassa, Spain and Gallery Aoyama, Tokyo, Japan.

  20. Verification of alternative dew point hygrometer for CV-LRT in MONJU. Short- and long-term verification of capacitance-type dew point hygrometer (Translated document)

    International Nuclear Information System (INIS)

    Ichikawa, Shoichi; Chiba, Yusuke; Ono, Fumiyasu; Hatori, Masakazu; Kobayashi, Takanori; Uekura, Ryoichi; Hashiri, Nobuo; Inuzuka, Taisuke; Kitano, Hiroshi; Abe, Hisashi

    2017-03-01

    To reduce the influence of maintenance of dew point hygrometers on the plant schedule at the prototype fast-breeder reactor MONJU, Japan Atomic Energy Agency examined a capacitance-type dew point hygrometer as an alternative to the lithium-chloride dew point hygrometer being used in the containment vessel leak rate test. As verifications, a capacitance-type dew point hygrometer was compared with a lithium-chloride dew point hygrometer under a containment vessel leak rate test condition. And the capacitance-type dew point hygrometer was compared with a high-precision-mirror-surface dew point hygrometer for long-term (2 years) in the containment vessel as an unprecedented try. A comparison of a capacitance-type dew point hygrometer with a lithium-chloride dew point hygrometer in a containment vessel leak rate test (Atmosphere: nitrogen, Testing time: 24 h) revealed no significant difference between the capacitance-type dew point hygrometer and the lithium-chloride dew point hygrometer. A comparison of the capacitance-type dew point hygrometer with the high-precision-mirror-surface dew point hygrometer for long-term verification (Atmosphere: air, Testing time: 24 months) revealed that the capacitance-type dew point hygrometer satisfied the instrumental specification (synthesized precision of detector and converter: ±2.04°C) specified in the Leak Rate Test Regulations for Nuclear Reactor Containment Vessel. It was confirmed that the capacitance-type dew point hygrometer can be used as a long-term alternative to the lithium-chloride dew point hygrometer without affecting the dew point hygrometer maintenance schedule of the MONJU plant. (author)

  1. Accurate prediction of the dew points of acidic combustion gases by using an artificial neural network model

    International Nuclear Information System (INIS)

    ZareNezhad, Bahman; Aminian, Ali

    2011-01-01

    This paper presents a new approach based on using an artificial neural network (ANN) model for predicting the acid dew points of the combustion gases in process and power plants. The most important acidic combustion gases namely, SO 3 , SO 2 , NO 2 , HCl and HBr are considered in this investigation. Proposed Network is trained using the Levenberg-Marquardt back propagation algorithm and the hyperbolic tangent sigmoid activation function is applied to calculate the output values of the neurons of the hidden layer. According to the network's training, validation and testing results, a three layer neural network with nine neurons in the hidden layer is selected as the best architecture for accurate prediction of the acidic combustion gases dew points over wide ranges of acid and moisture concentrations. The proposed neural network model can have significant application in predicting the condensation temperatures of different acid gases to mitigate the corrosion problems in stacks, pollution control devices and energy recovery systems.

  2. Instrument air dew point requirements -- 108-P, L, K

    International Nuclear Information System (INIS)

    Fairchild, P.N.

    1994-01-01

    The 108 Building dew point analyzers measure dew point at atmospheric pressure. Existing 108 Roundsheets state the maximum dew point temperature shall be less than -50 F. After repeatedly failing to maintain a -50 F dew point temperature Reactor Engineering researched the basis for the existing limit. This report documents the results of the study and provides technical justification for a new maximum dew point temperature of -35 F at atmospheric pressure as read by the 108 building dew point analyzers

  3. Automatic dew-point temperature sensor.

    Science.gov (United States)

    Graichen, H; Rascati, R; Gonzalez, R R

    1982-06-01

    A device is described for measuring dew-point temperature and water vapor pressure in small confined areas. The method is based on the deposition of water on a cooled surface when at dew-point temperature. A small Peltier module lowers the temperature of two electrically conductive plates. At dew point the insulating gap separating the plates becomes conductive as water vapor condenses. Sensors based on this principle can be made small and rugged and can be used for measuring directly the local water vapor pressure. They may be installed within a conventional ventilated sweat capsule used for measuring water vapor loss from the skin surface. A novel application is the measurement of the water vapor pressure gradients across layers of clothing worn by an exercising subject.

  4. SHORT COMMUNICATION: Recognition of supercooled dew in a quartz crystal microbalance dew-point sensor by slip phenomena

    Science.gov (United States)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Byung-Il

    2007-10-01

    Distinguishing between a supercooled dew and frost below 0 °C in dew/frost-point measurements is an important and challenging problem that has not yet been completely solved. This study presents a new method for the recognition of a supercooled dew in a dew/frost-point sensor. A quartz crystal microbalance (QCM) sensor was used as a dew/frost-point sensor to detect a dew and a supercooled dew as well as frost. The slip phenomenon occurring at an interface between the water droplet and the surface of the quartz crystal resonator of the QCM sensor gives a simple and accurate way of distinguishing between a supercooled dew and frost below 0 °C. This method can give a highly accurate measurement of the dew or the frost point without misreading in the dew-point sensor at temperatures below 0 °C.

  5. Analysis of Multicomponent Adsorption Close to a Dew Point

    DEFF Research Database (Denmark)

    Shapiro, Alexander; Stenby, Erling Halfdan

    1998-01-01

    We develop the potential theory of multicomponent adsorption close to a dew point. The approach is based on an asymptotic adsorption equation (AAE) which is valid in a vicinity of the dew point. By this equation the thickness of the liquid film is expressed through thermodynamic characteristics...... and the direct calculations, even if the mixture is not close to a dew point.Key Words: adsorption; potential theory; multicomponent; dew point....

  6. Accurate dew-point measurement over a wide temperature range using a quartz crystal microbalance dew-point sensor

    Science.gov (United States)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il

    2008-11-01

    Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (-90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range.

  7. Accurate dew-point measurement over a wide temperature range using a quartz crystal microbalance dew-point sensor

    International Nuclear Information System (INIS)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il

    2008-01-01

    Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (−90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range

  8. A new comparison method for dew-point generators

    Science.gov (United States)

    Heinonen, Martti

    1999-12-01

    A new method for comparing dew-point generators was developed at the Centre for Metrology and Accreditation. In this method, the generators participating in a comparison are compared with a transportable saturator unit using a dew-point comparator. The method was tested by constructing a test apparatus and by comparing it with the MIKES primary dew-point generator several times in the dew-point temperature range from -40 to +75 °C. The expanded uncertainty (k = 2) of the apparatus was estimated to be between 0.05 and 0.07 °C and the difference between the comparator system and the generator is well within these limits. In particular, all of the results obtained in the range below 0 °C are within ±0.03 °C. It is concluded that a new type of a transfer standard with characteristics most suitable for dew-point comparisons can be developed on the basis of the principles presented in this paper.

  9. Influence of the burning point on the dew point in a diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Teetz, C.

    1982-06-01

    A computation on the influence of the ignition point on the dew point in a cylinder of a diesel engine is presented. The cylinder-pressure diagrams are shown. The results of computation are given. A later ignition point diminishes the area with cylinder wall temperatures below the dew point. The endangering by cylinder wall temperatures below the dew point is illustrated.

  10. Dew-point measurements at high water vapour pressure

    Science.gov (United States)

    Lomperski, S.; Dreier, J.

    1996-05-01

    A dew-point meter capable of measuring humidity at high vapour pressure and high temperature has been constructed and tested. Humidity measurements in pure steam were made over the temperature range 100 - 1500957-0233/7/5/003/img1C and a vapour pressure range of 1 - 4 bar. The dew-point meter performance was assessed by comparing measurements with a pressure transmitter and agreement between the two was within 0957-0233/7/5/003/img2% relative humidity. Humidity measurements in steam - air mixtures were also made and the dew-point meter readings were compared to those of a zirconia oxygen sensor. For these tests the dew-point meter readings were generally within 0957-0233/7/5/003/img2% relative humidity of the oxygen sensor measurements.

  11. Protection of HCl dew point corrosion in municipal incinerators

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, S.; Tsuruta, T.; Maeda, N.

    1976-12-01

    HCl dew point corrosion is often observed on the components of municipal incinerators used for burning wastes which contain polyvinyl chloride. In order to solve the problem, the relation between concentrations of gaseous HCl and the corresponding dew points as well as concentrations of condensed HCl, was investigated. A series of HCl dipping tests for the materials concerned was performed and the dip test results were compared with in-plant tests. As a result it was concluded that HCl dew point corrosion can be reliably predicted from measurements of HCl concentrations in the water and in the gas and the partial pressure of the saturated steam at the dew point.

  12. Development of sulfuric acid dew point corrosion resistant stainless steel for smokestacks and its ducts. Entotsu endoyo tairyusan roten fushoku stainless ko no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Sato, E.; Matsuhashi, R.; Koseki, T. (Nippon Steel Corp., Tokyo (Japan)); Ebara, R.; Nakamoto, H. (Mitsubishi Heavy Industries, Ltd., Tokyo (Japan))

    1993-05-20

    A new corrosion resistant steel was developed as a metal system lining material to prevent sulfuric acid dew point corrosion in smokestacks and ducts. SO3 in stack gas turns to sulfuric acid as a result of reacting with coexistent moisture in non-steady conditions during boiler actuation and shutdown when smokestack walls have low temperatures. When sulfuric acid thus generated contacts with metallic materials at temperatures lower than the sulfuric acid dew point temperature, sulfuric acid dew point corrosion occurs. During boiler steady operation, localized corrosion develops at clearance between salt deposits and the metallic materials. In order to improve the corrosion resistance, Mo, Cu and N were added in a reasonable range of amount. Entire surface corrosion resistance and local corrosion resistance were experimented in aqueous solutions simulating the smokestack environments to derive relational formulas with steel compositions. The new corrosion resistant steel met the the entire surface and local corrosion resistance requirements and was found economical. Low torsional velocity tensile and U-bend tests proved the steel satisfying the stress corrosion resistance requirement. Semi-automatic CO2 welding and shielded are welding provided good workability with no cracking, and impact strength and corrosion resistance in joints equivalent to those in the base material. 3 refs., 4 figs., 4 tabs.

  13. Relationship between relative humidity and the dew point ...

    African Journals Online (AJOL)

    This research was aimed at determining the relationship between relative humidity and the dew point temperature in Benin City, Edo State, Nigeria. The dew point temperature was approximated from the measured air temperature and relative humidity with the aid of a currently self-designed weather monitoring system.

  14. Comparison of dew point temperature estimation methods in Southwestern Georgia

    Science.gov (United States)

    Marcus D. Williams; Scott L. Goodrick; Andrew Grundstein; Marshall Shepherd

    2015-01-01

    Recent upward trends in acres irrigated have been linked to increasing near-surface moisture. Unfortunately, stations with dew point data for monitoring near-surface moisture are sparse. Thus, models that estimate dew points from more readily observed data sources are useful. Daily average dew temperatures were estimated and evaluated at 14 stations in...

  15. Tar dew point analyser as a tool in biomass gasification

    Energy Technology Data Exchange (ETDEWEB)

    Vreugdenhil, B.J.; Kuipers, J. [ECN Biomass, Coal and Environmental Research, Petten (Netherlands)

    2008-08-15

    Application of the Tar Dew point Analyzer (TDA) in different biomass based gasification systems and subsequent gas cleaning setups has been proven feasible. Such systems include BFB gasifiers, CFB gasifier and fixed bed gasifiers, with tar crackers or different scrubbers for tar removal. Tar dew points obtained with the TDA give direct insight in the performance of the gas cleaning section and help prevent any tar related problems due to condensation. The current TDA is capable of measuring tar dew points between -20 to 200C. This manuscript will present results from 4 different gasification setups. The range of measured tar dew points is -7 to 164C with comparable results from the calculated dew points based on the SPA measurements. Further detail will be presented on the differences between TDA and SPA results and explanations will be given for deviations that occurred. Improvements for the TDA regarding future work will be presented.

  16. A quartz crystal microbalance dew point sensor without frequency measurement

    Science.gov (United States)

    Wang, Guohua; Zhang, Weishuo; Wang, Shuo; Sun, Jinglin

    2014-11-01

    This work deals with the design of a dew point sensor based on Quartz Crystal Microbalance (QCM) without measuring the frequency. This idea is inspired by the fact that the Colpitts oscillation circuit will stop oscillating when the QCM works in the liquid media. The quartz crystal and the electrode are designed through the finite element simulation and the stop oscillating experiment is conducted to verify the sensibility. Moreover, the measurement result is calibrated to approach the true value. At last a series of dew points at the same temperature is measured with the designed sensor. Results show that the designed dew point sensor is able to detect the dew point with the proper accuracy.

  17. A microwave resonance dew-point hygrometer

    Science.gov (United States)

    Underwood, R. J.; Cuccaro, R.; Bell, S.; Gavioso, R. M.; Madonna Ripa, D.; Stevens, M.; de Podesta, M.

    2012-08-01

    We report the first measurements of a quasi-spherical microwave resonator used as a dew-point hygrometer. In conventional dew-point hygrometers, the condensation of water from humid gas flowing over a mirror is detected optically, and the mirror surface is then temperature-controlled to yield a stable condensed layer. In our experiments we flowed moist air from a humidity generator through a quasi-spherical resonator and detected the onset of condensation by measuring the frequency ratio of selected microwave modes. We verified the basic operation of the device over the dew-point range 9.5-13.5 °C by comparison with calibrated chilled-mirror hygrometers. These tests indicate that the microwave method may allow a quantitative estimation of the volume and thickness of the water layer which is condensed on the inner surface of the resonator. The experiments reported here are preliminary due to the limited time available for the work, but show the potential of the method for detecting not only water but a variety of other liquid or solid condensates. The robust all-metal construction should make the device appropriate for use in industrial applications over a wide range of temperatures and pressures.

  18. A microwave resonance dew-point hygrometer

    International Nuclear Information System (INIS)

    Underwood, R J; Bell, S; Stevens, M; De Podesta, M; Cuccaro, R; Gavioso, R M; Ripa, D Madonna

    2012-01-01

    We report the first measurements of a quasi-spherical microwave resonator used as a dew-point hygrometer. In conventional dew-point hygrometers, the condensation of water from humid gas flowing over a mirror is detected optically, and the mirror surface is then temperature-controlled to yield a stable condensed layer. In our experiments we flowed moist air from a humidity generator through a quasi-spherical resonator and detected the onset of condensation by measuring the frequency ratio of selected microwave modes. We verified the basic operation of the device over the dew-point range 9.5–13.5 °C by comparison with calibrated chilled-mirror hygrometers. These tests indicate that the microwave method may allow a quantitative estimation of the volume and thickness of the water layer which is condensed on the inner surface of the resonator. The experiments reported here are preliminary due to the limited time available for the work, but show the potential of the method for detecting not only water but a variety of other liquid or solid condensates. The robust all-metal construction should make the device appropriate for use in industrial applications over a wide range of temperatures and pressures. (paper)

  19. A New Primary Dew-Point Generator at TUBITAK UME

    Science.gov (United States)

    Oğuz Aytekin, S.; Karaböce, N.; Heinonen, M.; Sairanen, H.

    2018-05-01

    An implementation of a new low-range primary humidity generator as a part of an international collaboration between TUBITAK UME and VTT MIKES was initiated as a EURAMET Project Number 1259. The dew-point generator was designed and constructed within the scope of the cooperation between TUBITAK UME and VTT MIKES in order to extend the dew-point temperature measurement capability of Humidity Laboratory of TUBITAK UME down to - 80 °C. The system was thoroughly characterized and validated at TUBITAK UME to support the evidence for dew-point temperature uncertainties. The new generator has a capability of operating in the range of - 80 °C to +10 °C, but at the moment, it was characterized down to - 60 °C. The core of the generator system is a saturator which is fully immersed in a liquid bath. Dry air is supplied to the saturator through a temperature-controlled pre-saturator. The operation of the system is based on the single-pressure generation method with a single pass, i.e., the dew-point temperature is only controlled by the saturator temperature, and the humidity-controlled air is not returned to the system after leaving of the saturator. The metrological performance of the saturator was investigated thoroughly at both National Metrology Institutes. The pre-saturator was also tested using a thermostatic bath at VTT MIKES prior to sending them to TUBITAK UME. This paper describes the principle and design of the generator in detail. The dew-point measurement system and the corresponding uncertainty analysis of the dew-point temperature scale realized with the generator in the range from - 60 °C to 10 °C is also presented.

  20. Calibration of Relative Humidity Sensors using a Dew Point Generator

    OpenAIRE

    Brooks, Milo

    2010-01-01

    A relative humidity sensor can be calibrated using a dew point generator to continuously supply an air stream of known constant humidity and a temperature chamber to control the dew point and ambient temperature.

  1. Investigation of the dew-point temperature scale maintained at the MIKES

    Science.gov (United States)

    Heinonen, Martti

    1999-01-01

    For the investigation of the dew-point temperature scale realized by the MIKES primary dew-point generator, a two-pressure generator and a dew-point indicator based on condensation in a cooled coil were constructed and tested. In addition, a chilled mirror hygrometer was validated by means of an uncertainty analysis. The comparison of these systems was focused on the dew-point temperature range from 0957-0233/10/1/010/img1 to 0957-0233/10/1/010/img2 but measurements were made up to 0957-0233/10/1/010/img3. The generator systems were compared using a dew-point comparator based on two relative humidity sensors. According to the results of the comparisons, the differences between the measurement systems were less than 0957-0233/10/1/010/img4, while the expanded uncertainty of the MIKES generator was between 0957-0233/10/1/010/img5 and 0957-0233/10/1/010/img6. The uncertainty of the other systems was from 0957-0233/10/1/010/img7 to 0957-0233/10/1/010/img8. It was concluded that the dew-point temperature scale was not dependent on the realization method.

  2. Evaluation of the physical dew point in the economizer of a combined cycle burning natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Pena, F.; Blanco, J.M. [Universidad del Pais Vasco/E.H.U. Alameda de Urquijo s/n, Bilbao (Spain). Dpto. Maquinas y Motores Termicos, Escuela Sup. de Ingenieria

    2007-08-15

    Natural gas contents a considerable percentage of hydrogen, so is obvious to expect an amount of water vapour in its combustion exhaust gases, which would raise the dew point temperature. That means a higher speed of corrosion over the whole exposed physical area, which could represent a serious risk of breakdown, especially in pressurized hot-water equipments. In this work, a new methodology for determining the physical dew point inside a economizer depending on the fuel type burned (in this case is natural gas) has been developed. The calculation of the total amount of condensed water has also been carried out as well as the localization of the area where this condensation occurs. Acid dew point has not been taken into account here although exhaust gases are acidic, due mainly to the low sulphur content which is almost undetectable when burning natural gas, but it will be performed in a later study coming soon. (author)

  3. New correlation of dew point temperature for gases with low H/sub 2/SO/sub 4/ content

    Energy Technology Data Exchange (ETDEWEB)

    Fieg, J.

    1986-04-01

    During the last years increased concern about pollution problems has encouraged the development of many methods to remove particulate and other undesirable substances from flue gases. These efforts have also brought renewed interest in aqueous sulfuric acid vapour-liquid equilibrium for predicting the flue gas dew point. This article presents the principal methods, contributing to solve the inherent problems and summarizes the available data and presents a new empirical correlation of the dew point as a function of the partial pressures of sulfuric acid and the water in the vapour.

  4. Measurements to determine the sulfuric acid dew point and the SO sub 3 concentration in flue gas of power plant vessels. Messungen zur Bestimmung des Saeuretaupunktes und der SO sub 3 -Konzentration im Rauchgas von Kraftwerkskesseln

    Energy Technology Data Exchange (ETDEWEB)

    Derichs, W.; Menden, W. (RWE Energie AG, Bergheim (Germany)); Ebel, P.K. (Apparatebau Hundsbach GmbH, Baden-Baden (Germany))

    1990-01-01

    Among the customary methods of dew point determination, the technique of recording the increase in conductivity between two electrodes at the moment of acid condensing onto them, and measuring at the same time the temperature of the sensor, is appropriate to determine the sulfuric acid dew point in dust-laden flue gas. By means of the sensitivity of a newly developed sensor, the accuracy of the measurement method could be improved to such an extent that also low acid dew points and rapid changes can be recorded reliably. Measurements have shown that the acid dew point primarily depends on the SO{sub 3} content which is substantially determined by the sulfur content of the fuel and the type of flue gas ducts. Further influential quantities include flue gas humidity, air surplus, other gaseous flue gas components such as HCl and HF, as well as the quantity, composition and temperature-dependent adsorption capability of the flue dusts. (orig./BBR).

  5. Initial response of an automatic dew-point hygrometer using [beta]-ray backscattering

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shigeaki (Saitama Univ., Urawa (Japan). Faculty of Engineering)

    1992-05-01

    This paper describes the initial response of an automatic dew-point hygrometer using [beta]-ray backscattering. The response time after starting of measurement was evaluated in which the dew point measured with the hygrometer reached a value of 90 percent of the correct dew point in its response. Theoretical calculation was made by means of the loop transfer function of a control system employed in the hygrometer. The response times ranged from 1.7 min to 16 min corresponding to the dew point of 47.5degC and -6degC, respectively, and agreed well with experimental ones. (author).

  6. A micro dew point sensor with a thermal detection principle

    Science.gov (United States)

    Kunze, M.; Merz, J.; Hummel, W.-J.; Glosch, H.; Messner, S.; Zengerle, R.

    2012-01-01

    We present a dew point temperature sensor with the thermal detection of condensed water on a thin membrane, fabricated by silicon micromachining. The membrane (600 × 600 × ~1 µm3) is part of a silicon chip and contains a heating element as well as a thermopile for temperature measurement. By dynamically heating the membrane and simultaneously analyzing the transient increase of its temperature it is detected whether condensed water is on the membrane or not. To cool the membrane down, a peltier cooler is used and electronically controlled in a way that the temperature of the membrane is constantly held at a value where condensation of water begins. This temperature is measured and output as dew point temperature. The sensor system works in a wide range of dew point temperatures between 1 K and down to 44 K below air temperature. In experimental investigations it could be proven that the deviation of the measured dew point temperatures compared to reference values is below ±0.2 K in an air temperature range of 22 to 70 °C. At low dew point temperatures of -20 °C (air temperature = 22 °C) the deviation increases to nearly -1 K.

  7. A micro dew point sensor with a thermal detection principle

    International Nuclear Information System (INIS)

    Kunze, M; Merz, J; Glosch, H; Messner, S; Zengerle, R; Hummel, W-J

    2012-01-01

    We present a dew point temperature sensor with the thermal detection of condensed water on a thin membrane, fabricated by silicon micromachining. The membrane (600 × 600 × ∼1 µm 3 ) is part of a silicon chip and contains a heating element as well as a thermopile for temperature measurement. By dynamically heating the membrane and simultaneously analyzing the transient increase of its temperature it is detected whether condensed water is on the membrane or not. To cool the membrane down, a peltier cooler is used and electronically controlled in a way that the temperature of the membrane is constantly held at a value where condensation of water begins. This temperature is measured and output as dew point temperature. The sensor system works in a wide range of dew point temperatures between 1 K and down to 44 K below air temperature. In experimental investigations it could be proven that the deviation of the measured dew point temperatures compared to reference values is below ±0.2 K in an air temperature range of 22 to 70 °C. At low dew point temperatures of −20 °C (air temperature = 22 °C) the deviation increases to nearly −1 K

  8. New methods of subcooled water recognition in dew point hygrometers

    Science.gov (United States)

    Weremczuk, Jerzy; Jachowicz, Ryszard

    2001-08-01

    Two new methods of sub-cooled water recognition in dew point hygrometers are presented in this paper. The first one- impedance method use a new semiconductor mirror in which the dew point detector, the thermometer and the heaters were integrated all together. The second one an optical method based on a multi-section optical detector is discussed in the report. Experimental results of both methods are shown. New types of dew pont hydrometers of ability to recognized sub-cooled water were proposed.

  9. Dew point of combustion products of coal from the Berezovo deposit

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, V.A. (UralVTI (USSR))

    1990-11-01

    Evaluates properties of brown coal from the Berezovo deposit, Kansk-Achinsk basin, and properties of its combustion products. Coal properties are the following: sulfur content from 0.26 to 0.49%, ash content from 3.49 to 6.58%, moisture content from 31.6 to 36.9%, calorific value from 14,200 to 15,840 kJ/kg. Dew point of the combustion products amounts to 51 C and is equal to that of water vapor present in flue gases. Changing boiler output does not influence dew point. Increase in the excess air coefficient from 1.2 to 1.4 results in an increase in dew point by 2-3 K; further increase in air excess coefficient to 1.64 causes a decline in dew point by 3-4 K. 2 refs.

  10. The dew point response of the annulus gas system of Bruce NGS A

    International Nuclear Information System (INIS)

    Kenchington, J.; Ellis, P.J.; Meranda, D.

    1983-01-01

    The dew point response of the Annulus Gas System in Bruce A, Units 1 and 2 has been modelled in order to alert the operator of the presence of heavy water and to estimate the leak rate into the annulus. The computer model can be easily adapted to determine the Annulus Gas System dew point response in any station. It models the complex arrangement of the system and the transportation of moisture through the annuli by a combination of plug flow and mixing of CO 2 and D 2 O vapor. It predicts the response of the dew point monitor for a range of specified leak rates and positions of a leaking channel in a string of channels. This model has been used to calculate the variation of dew point and rate of change of dew point with respect to time (t). It shows that there is a maximum in the rate of dew point change (dT/dt) with respect to the corresponding dew point (T). This maximum is unique for a given leak rate and channel position. It is independent of the starting time for the leak. The computer programme has been verified by an analytical solution for the model

  11. Dew Point modelling using GEP based multi objective optimization

    OpenAIRE

    Shroff, Siddharth; Dabhi, Vipul

    2013-01-01

    Different techniques are used to model the relationship between temperatures, dew point and relative humidity. Gene expression programming is capable of modelling complex realities with great accuracy, allowing at the same time, the extraction of knowledge from the evolved models compared to other learning algorithms. We aim to use Gene Expression Programming for modelling of dew point. Generally, accuracy of the model is the only objective used by selection mechanism of GEP. This will evolve...

  12. Memory persistency and nonlinearity in daily mean dew point across India

    Science.gov (United States)

    Ray, Rajdeep; Khondekar, Mofazzal Hossain; Ghosh, Koushik; Bhattacharjee, Anup Kumar

    2016-04-01

    Enterprising endeavour has been taken in this work to realize and estimate the persistence in memory of the daily mean dew point time series obtained from seven different weather stations viz. Kolkata, Chennai (Madras), New Delhi, Mumbai (Bombay), Bhopal, Agartala and Ahmedabad representing different geographical zones in India. Hurst exponent values reveal an anti-persistent behaviour of these dew point series. To affirm the Hurst exponent values, five different scaling methods have been used and the corresponding results are compared to synthesize a finer and reliable conclusion out of it. The present analysis also bespeaks that the variation in daily mean dew point is governed by a non-stationary process with stationary increments. The delay vector variance (DVV) method has been exploited to investigate nonlinearity, and the present calculation confirms the presence of deterministic nonlinear profile in the daily mean dew point time series of the seven stations.

  13. Using dew points to estimate savings during a planned cooling shutdown

    Science.gov (United States)

    Friedlein, Matthew T.; Changnon, David; Musselman, Eric; Zielinski, Jeff

    2005-12-01

    In an effort to save money during the summer of 2003, Northern Illinois University (NIU) administrators instituted a four-day working week and stopped air conditioning buildings for the three-day weekends (Friday through Sunday). Shutting down the air conditioning systems caused a noticeable drop in electricity usage for that part of the campus that features in our study, with estimated total electricity savings of 1,268,492 kilowatt-hours or 17% of the average usage during that eight-week period. NIU's air conditioning systems, which relied on evaporative cooling to function, were sensitive to dew point levels. Greatest savings during the shutdown period occurred on days with higher dew points. An examination of the regional dew point climatology (1959 2003) indicated that the average summer daily dew point for 2003 was 14.9°C (58.8°F), which fell in the lowest 20% of the distribution. Based on the relationship between daily average dew points and electrical usage, a predictive model that could estimate electrical daily savings was created. This model suggests that electrical savings related to any future three-day shutdowns over summer could be much greater in more humid summers. Studies like this demonstrate the potential value of applying climatological information and of integrating this information into practical decision-making.

  14. Temperature distribution model for the semiconductor dew point detector

    Science.gov (United States)

    Weremczuk, Jerzy; Gniazdowski, Z.; Jachowicz, Ryszard; Lysko, Jan M.

    2001-08-01

    The simulation results of temperature distribution in the new type silicon dew point detector are presented in this paper. Calculations were done with use of the SMACEF simulation program. Fabricated structures, apart from the impedance detector used to the dew point detection, contained the resistive four terminal thermometer and two heaters. Two detector structures, the first one located on the silicon membrane and the second one placed on the bulk materials were compared in this paper.

  15. Experimental investigation of a super performance dew point air cooler

    International Nuclear Information System (INIS)

    Xu, Peng; Ma, Xiaoli; Zhao, Xudong; Fancey, Kevin

    2017-01-01

    Highlights: •The cooler had a complex heat & mass exchanger with an advanced wet material layer. •Intermittent water supply scheme was implemented. •The cooler achieved 100–160% higher COP compared to the existing dew point coolers. •Electricity use of the cooler was reduced by 50–70% compared to existing dew coolers. •This optimal working air ratio was 0.364 that enabled maximised cooling effectiveness. -- Abstract: This paper presents an experimental investigation of a super performance dew point air cooler which, by employing a super performance wet material layer, innovative heat and mass exchanger and intermittent water supply scheme, has achieved a significantly higher energy efficiency (i.e. Coefficient of Performance, COP) and a much lower electrical energy use compared to the existing air coolers of the same type. This involves the dedicated system design & construction, fully planned experimental testing under various simulated climatic conditions representing the climate of hot & dry, warm & dry, moderate, warm & humid and standard lab testing condition, testing results analysis and discussion, as well as the parallel comparison against the commercial dew point air cooler. Under the standard test condition, i.e. dry bulb temperature of 37.8 °C and coincident wet bulb temperature of 21.1 °C, the prototype cooler achieved the wet-bulb cooling effectiveness of 114% and dew-point cooling effectiveness of 75%, yielding a significantly high COP value of 52.5 at the optimal working air ratio of 0.364. The testing also indicated that the lower inlet air relative humidity led to a higher cooling efficiency, while the lower cooling output helped increase COP and cooling effectiveness (including the wet-bulb effectiveness and dew-point effectiveness) of the cooler.

  16. Feedback dew-point sensor utilizing optimally cut plastic optical fibres

    Science.gov (United States)

    Hadjiloucas, S.; Irvine, J.; Keating, D. A.

    2000-01-01

    A plastic optical fibre reflectance sensor that makes full use of the critical angle of the fibres is implemented to monitor dew formation on a Peltier-cooled reflector surface. The optical configuration permits isolation of optoelectronic components from the sensing head and better light coupling between the reflector and the detecting fibre, giving a better signal of the onset of dew formation on the reflector. Continuous monitoring of the rate of change in reflectance as well as the absolute reflectance signals, the use of a novel polymethyl-methacrylate-coated hydrophobic film reflector on the Peltier element and the application of feedback around the point of dew formation, further reduces the possibility of contamination of the sensor head. Under closed-loop operation, the sensor is capable of cycling around the point of dew formation at a frequency of 2.5 Hz.

  17. Method and apparatus for continuously detecting and monitoring the hydrocarbon dew-point of gas

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, G.J.; Pritchard, F.R.

    1987-08-04

    This patent describes a method and apparatus for continuously detecting and monitoring the hydrocarbon dew-point of a gas. A gas sample is supplied to a dew-point detector and the temperature of a portion of the sample gas stream to be investigated is lowered progressively prior to detection until the dew-point is reached. The presence of condensate within the flowing gas is detected and subsequently the supply gas sample is heated to above the dew-point. The procedure of cooling and heating the gas stream continuously in a cyclical manner is repeated.

  18. Numerical study of a novel dew point evaporative cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Riangvilaikul, B.; Kumar, S. [Energy Field of Study, School of Environment, Resources and Development, Asian Institute of Technology, P.O. Box 4, Klong Luang, Pathumthani 12120 (Thailand)

    2010-11-15

    Dew point evaporative cooling system is an alternative to vapor compression air conditioning system for sensible cooling of ventilation air. This paper presents the theoretical performance of a novel dew point evaporative cooling system operating under various inlet air conditions (covering dry, moderate and humid climate) and influence of major operating parameters (namely, velocity, system dimension and the ratio of working air to intake air). A model of the dew point evaporative cooling system has been developed to simulate the heat and mass transfer processes. The outlet air conditions and system effectiveness predicted by the model using numerical method for known inlet parameters have been validated with experimental findings and with recent literature. The model was used to optimize the system parameters and to investigate the system effectiveness operating under various inlet air conditions. (author)

  19. Dew point measurement technique utilizing fiber cut reflection

    Science.gov (United States)

    Kostritskii, S. M.; Dikevich, A. A.; Korkishko, Yu. N.; Fedorov, V. A.

    2009-05-01

    The fiber optical dew point hygrometer based on change of reflection coefficient for fiber cut has been developed and examined. We proposed and verified the model of condensation detector functioning principle. Experimental frost point measurements on air with different frost points have been performed.

  20. An experimental study of a novel dew point evaporative cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Riangvilaikul, B.; Kumar, S. [Energy Field of Study, School of Environment, Resources and Development, Asian Institute of Technology, P.O. Box 4, Klong Luang, Pathumthani 12120 (Thailand)

    2010-05-15

    A novel dew point evaporative cooling system for sensible cooling of the ventilation air for air conditioning application was constructed and experiments were carried out to investigate the outlet air conditions and the system effectiveness at different inlet air conditions (temperature, humidity and velocity) covering dry, temperate and humid climates. The results showed that wet bulb effectiveness ranged between 92 and 114% and the dew point effectiveness between 58 and 84%. A continuous operation of the system during a typical day of summer season in a hot and humid climate showed that wet bulb and dew point effectiveness were almost constant at about 102 and 76%, respectively. The experiment results were compared with some recent studies in literature. (author)

  1. Pressure-Drop Considerations in the Characterization of Dew-Point Transfer Standards at High Temperatures

    Science.gov (United States)

    Mitter, H.; Böse, N.; Benyon, R.; Vicente, T.

    2012-09-01

    During calibration of precision optical dew-point hygrometers (DPHs), it is usually necessary to take into account the pressure drop induced by the gas flow between the "point of reference" and the "point of use" (mirror or measuring head of the DPH) either as a correction of the reference dew-point temperature or as part of the uncertainty estimation. At dew-point temperatures in the range of ambient temperature and below, it is sufficient to determine the pressure drop for the required gas flow, and to keep the volumetric flow constant during the measurements. In this case, it is feasible to keep the dry-gas flow into the dew-point generator constant or to measure the flow downstream the DPH at ambient temperature. In normal operation, at least one DPH in addition to the monitoring DPH are used, and this operation has to be applied to each instrument. The situation is different at high dew-point temperatures up to 95 °C, the currently achievable upper limit reported in this paper. With increasing dew-point temperatures, the reference gas contains increasing amounts of water vapour and a constant dry-gas flow will lead to a significant enhanced volume flow at the conditions at the point of use, and therefore, to a significantly varying pressure drop depending on the applied dew-point temperature. At dew-point temperatures above ambient temperature, it is also necessary to heat the reference gas and the mirror head of the DPH sufficiently to avoid condensation which will additionally increase the volume flow and the pressure drop. In this paper, a method is provided to calculate the dry-gas flow rate needed to maintain a known wet-gas flow rate through a chilled mirror for a range of temperature and pressures.

  2. Measurement of dew droplets in initial deposition at dew point by using a phase-shift interference microscope

    Science.gov (United States)

    Matsumoto, Shigeaki; Toyooka, Satoru; Hoshino, Mitsuo

    2002-09-01

    In order to measure the total mass per unit area of dew droplets deposited on a metal plate in the dew-point hygrometer, the shape of a dew droplet deposited on a copper plate was measured accurately by using an interference microscope that employed a phase-shift technique. The microscope was constructed by adding a piezoelectric transducer to an usual interference microscope. A simple method that uses a conventional speaker horn and an optical fiber cable was introduced to depress speckle noise. The shape of a dew droplet deposited on the copper plate surface with 0.1 μm in average roughness was measured with an accuracy of +/-3nm. The mass of a dew droplet could be calculated numerically from the volume of its shape and was of the order of 10-9 g. The total mass of dew droplets deposited per unit area and the deposition velocity were obtained under a gentle wind. The total mass was the order of 10-5 g/cm2 at the beginning of deposition and the deposition velocity was ranged from 2x10-6 to 6x10-5 g/cm2.min.

  3. Bubble and Dew Point Calculations in Multicomponent and Multireactive Mixtures

    OpenAIRE

    Bonilla-Petriciolet, A.; Acosta-Martínez, A.; Bravo-Sánchez, U. I.; Segovia-Hernández, J. G.

    2006-01-01

    Bubble and dew point calculations are useful in chemical engineering and play an important role in the study of separation equipments for non-reactive and reactive mixtures. To the best of the authors’s knowledge, few methods have been proposed for these calculations in systems with several chemical reactions. The objective of this paper is to introduce new conditions for performing bubble and dew point calculations in reactive mixtures. We have developed these conditions based on the a...

  4. Automatic dew-point hygrometer making use of US -ray backscattering and controlled at the constant amount of dew

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shigeaki; Kobayashi, Hisanobu

    1988-08-01

    A control system which consists of proportional and integral control to maintain the constant amount of dew was developed in this hygrometer. The dew points were measured within an accuracy of +-1 deg C in the ranging from -4 to 32 deg C. The response time for suddenly changing humidity was about 8 min.

  5. Correlation of dew- and bubble-point curves for binary refrigerant mixtures. [Correlation between dew-point pressure(saturated vapor state) and bubble-point pressure(saturated liquid state)]. Niseibunkei kongo reibai no roten oyobi futten kyokusen no sokan

    Energy Technology Data Exchange (ETDEWEB)

    Yada, N. (Kanagawa Institute of Technology, Kanagawa (Japan)); Watanabe, K. (Keio University, Tokyo (Japan). Faculty of Science and Technology)

    1991-12-25

    The paper makes a correlation expressing dew- and bubble-point curves using measured values for seven binary refrigerant freon-mixtures. In most binary systems at the same temperature, the pressure shows a different value between in a saturated vapor state (dew-point pressure) and in a saturated liquid state (bubble-point pressure). The target is such correlation as has as simple a function form as possible and is able to estimate even near the critical point where it used to be difficult to estimate. The pressure difference between measured values of the dew- and bubble-point pressure and values calculated from Raoult's law showing an ideal mixture of fluid is expressed by a simple function form of reduced temperature Tr and molar fraction. Tr is thermodynamic temperature/critical temperature. Reproducibility of this correlation is less than {plus minus}3% of the pressure deviation. Concerning also the arbitary composition range and near the critical point, the dew- and bubble-point pressure can be calculated accurately. 24 refs., 4 figs., 5 tabs.

  6. An Investigation of the Relation Between Contact Thermometry and Dew-Point Temperature Realization

    Science.gov (United States)

    Benyon, R.; Böse, N.; Mitter, H.; Mutter, D.; Vicente, T.

    2012-09-01

    Precision optical dew-point hygrometers are the most commonly used transfer standards for the comparison of dew-point temperature realizations at National Metrology Institutes (NMIs) and for disseminating traceability to calibration laboratories. These instruments have been shown to be highly reproducible when properly used. In order to obtain the best performance, the resistance of the platinum resistance thermometer (PRT) embedded in the mirror is usually measured with an external, traceable resistance bridge or digital multimeter. The relation between the conventional calibration of miniature PRTs, prior to their assembly in the mirrors of state-of-the-art optical dew-point hygrometers and their subsequent calibration as dew-point temperature measurement devices, has been investigated. Standard humidity generators of three NMIs were used to calibrate hygrometers of different designs, covering the dew-point temperature range from -75 °C to + 95 °C. The results span more than a decade, during which time successive improvements and modifications were implemented by the manufacturer. The findings are presented and discussed in the context of enabling the optimum use of these transfer standards and as a basis for determining contributions to the uncertainty in their calibration.

  7. Integrated CMOS dew point sensors for relative humidity measurement

    Science.gov (United States)

    Savalli, Nicolo; Baglio, Salvatore; Castorina, Salvatore; Sacco, Vincenzo; Tringali, Cristina

    2004-07-01

    This work deals with the development of integrated relative humidity dew point sensors realized by adopting standard CMOS technology for applications in various fields. The proposed system is composed by a suspended plate that is cooled by exploiting integrated Peltier cells. The cold junctions of the cells have been spread over the plate surface to improve the homogeneity of the temperature distribution over its surface, where cooling will cause the water condensation. The temperature at which water drops occur, named dew point temperature, is a function of the air humidity. Measurement of such dew point temperature and the ambient temperature allows to know the relative humidity. The detection of water drops is achieved by adopting a capacitive sensing strategy realized by interdigited fixed combs, composed by the upper layer of the adopted process. Such a capacitive sensor, together with its conditioning circuit, drives a trigger that stops the cooling of the plate and enables the reading of the dew point temperature. Temperature measurements are achieved by means of suitably integrated thermocouples. The analytical model of the proposed system has been developed and has been used to design a prototype device and to estimate its performances. In such a prototype, the thermoelectric cooler is composed by 56 Peltier cells, made by metal 1/poly 1 junctions. The plate has a square shape with 200 μm side, and it is realized by exploiting the oxide layers. Starting from the ambient temperature a temperature variation of ΔT = 15 K can be reached in 10 ms thus allowing to measure a relative humidity greater than 40%.

  8. An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform

    Science.gov (United States)

    Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong

    2016-07-01

    The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.

  9. Trends in temperature and dew point at the summit of Mount Washington, New Hampshire, 1935-2004.

    Science.gov (United States)

    Grant, A. N.; Pszenny, A. A.; Fischer, E. V.

    2005-05-01

    Dry and wet bulb temperatures from sling psychrometer measurements taken every six hours from 1935 to 2004 at the summit of Mount Washington, located at 44 °16'N, 71 °18'W, 1914 m ASL have recently been digitized. Annual temperature has increased by 0.3°C, and annual dew point has decreased by 0.4°C over this 70-year period. Synoptic temperature has increased most in spring and winter, changing by 1.0°C and 0.5°C, respectively, while it has decreased slightly in summer and fall. Dew point has decreased in fall, summer, and winter, 0.9°C, 0.5°C, and 0.4°C respectively, and increased by 0.1°C in spring. Preliminary analysis suggests that some of the larger trends in winter and spring may be statistically significant; results of Monte Carlo simulations will be reported. Changes in dew point may be attributed to two factors. Decreasing dew points are expected if the temperature increases but the amount of water vapor present stays the same. Alternatively, lower dew points could be indicative of the presence of drier air. Other dew point climatologies of the continental United States for the second half of the century have shown mixed results, with increased dew points evident at some stations, decreased dew points at others, and no clear regional patterns.

  10. Measuring the exhaust gas dew point of continuously operated combustion plants

    Energy Technology Data Exchange (ETDEWEB)

    Fehler, D.

    1985-07-16

    Low waste-gas temperatures represent one means of minimizing the energy consumption of combustion facilities. However, condensation should be prevented to occur in the waste gas since this could result in a destruction of parts. Measuring the waste-gas dew point allows to control combustion parameters in such a way as to be able to operate at low temperatures without danger of condensation. Dew point sensors will provide an important signal for optimizing combustion facilities.

  11. Bubble-point and dew-point equation for binary refrigerant mixture R22-R142b

    Energy Technology Data Exchange (ETDEWEB)

    Liancheng Tan; Zhongyou Zhao; Yonghong Duan (Xi' an Jiaotong Univ., Xi' an (China). Dept. of Power Machinery Engineering)

    1992-01-01

    A bubble-point and dew-point equation (in terms either of temperature or of pressure is suggested for the refrigerant mixture R22-R142b), which is regarded as one of the alternatives to R12. This equation has been examined with experimental data. A modified Rackett equation for the calculation of the bubble-point volume is also proposed. Compared with the experimental data, the rms errors in the calculated values of the bubble-point temperature, the dew-point temperature, and the bubble-point volume are 1.093%, 0.947%, and 1.120%, respectively. The calculation covers a wide range of temperatures and pressures, even near the critical point. It is shown how the equations are extrapolated to calculate other binary refrigerant mixtures. (author)

  12. An automatic dew-point hygrometer making use of β-ray backscattering and controlled at the constant amount of dew

    International Nuclear Information System (INIS)

    Matsumoto, Shigeaki; Kobayashi, Hisanobu

    1988-01-01

    A control system which consists of proportional and integral control to maintain the constant amount of dew was developed in this hygrometer. The dew points were measured within an accuracy of ±1 deg C in the ranging from -4 to 32 deg C. The response time for suddenly changing humidity was about 8 min. (author)

  13. Estimation of dew point temperature using neuro-fuzzy and neural network techniques

    Science.gov (United States)

    Kisi, Ozgur; Kim, Sungwon; Shiri, Jalal

    2013-11-01

    This study investigates the ability of two different artificial neural network (ANN) models, generalized regression neural networks model (GRNNM) and Kohonen self-organizing feature maps neural networks model (KSOFM), and two different adaptive neural fuzzy inference system (ANFIS) models, ANFIS model with sub-clustering identification (ANFIS-SC) and ANFIS model with grid partitioning identification (ANFIS-GP), for estimating daily dew point temperature. The climatic data that consisted of 8 years of daily records of air temperature, sunshine hours, wind speed, saturation vapor pressure, relative humidity, and dew point temperature from three weather stations, Daego, Pohang, and Ulsan, in South Korea were used in the study. The estimates of ANN and ANFIS models were compared according to the three different statistics, root mean square errors, mean absolute errors, and determination coefficient. Comparison results revealed that the ANFIS-SC, ANFIS-GP, and GRNNM models showed almost the same accuracy and they performed better than the KSOFM model. Results also indicated that the sunshine hours, wind speed, and saturation vapor pressure have little effect on dew point temperature. It was found that the dew point temperature could be successfully estimated by using T mean and R H variables.

  14. Detection of Dew-Point by substantial Raman Band Frequency Jumps (A new Method)

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    Detection of Dew-Point by substantial Raman Band Frequency Jumps (A new Method). See poster at http://www.kemi.dtu.dk/~ajo/rolf/jumps.pdf......Detection of Dew-Point by substantial Raman Band Frequency Jumps (A new Method). See poster at http://www.kemi.dtu.dk/~ajo/rolf/jumps.pdf...

  15. Dew point fast measurement in organic vapor mixtures using quartz resonant sensor

    Science.gov (United States)

    Nie, Jing; Liu, Jia; Meng, Xiaofeng

    2017-01-01

    A fast dew point sensor has been developed for organic vapor mixtures by using the quartz crystal with sensitive circuits. The sensor consists of the quartz crystal and a cooler device. Proactive approach is taken to produce condensation on the surface of the quartz crystal, and it will lead to a change in electrical features of the quartz crystal. The cessation of oscillation was measured because this phenomenon is caused by dew condensation. Such a phenomenon can be used to detect the dew point. This method exploits the high sensitivity of the quartz crystal but without frequency measurement and also retains the stability of the resonant circuit. It is strongly anti-interfered. Its performance was evaluated with acetone-methanol mixtures under different pressures. The results were compared with the dew points predicted from the universal quasi-chemical equation to evaluate the performance of the proposed sensor. Though the maximum deviations of the sensor are less than 1.1 °C, it still has a fast response time with a recovery time of less than 10 s, providing an excellent dehumidifying performance.

  16. Dew point vs bubble point : a misunderstood constraint on gravity drainage processes

    Energy Technology Data Exchange (ETDEWEB)

    Nenninger, J. [N-Solv Corp., Calgary, AB (Canada); Gunnewiek, L. [Hatch Ltd., Mississauga, ON (Canada)

    2009-07-01

    This study demonstrated that gravity drainage processes that use blended fluids such as solvents have an inherently unstable material balance due to differences between dew point and bubble point compositions. The instability can lead to the accumulation of volatile components within the chamber, and impair mass and heat transfer processes. Case studies were used to demonstrate the large temperature gradients within the vapour chamber caused by temperature differences between the bubble point and dew point for blended fluids. A review of published data showed that many experiments on in-situ processes do not account for unstable material balances caused by a lack of steam trap control. A study of temperature profiles during steam assisted gravity drainage (SAGD) studies showed significant temperature depressions caused by methane accumulations at the outside perimeter of the steam chamber. It was demonstrated that the condensation of large volumes of purified solvents provided an efficient mechanism for the removal of methane from the chamber. It was concluded that gravity drainage processes can be optimized by using pure propane during the injection process. 22 refs., 1 tab., 18 figs.

  17. Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method.

    Science.gov (United States)

    Lin, Ningning; Meng, Xiaofeng; Nie, Jing

    2016-11-18

    In this paper, the influence of temperature on quartz crystal microbalance (QCM) sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of -3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability.

  18. Temporal trends in United States dew point temperatures

    Science.gov (United States)

    Robinson, Peter J.

    2000-07-01

    In this study, hourly data for the 1951-1990 period for 178 stations in the coterminous United States were used to establish temporal trends in dew point temperature. Although the data had been quality controlled previously (Robinson, 1998. Monthly variations of dew point temperatures in the coterminous United States. International Journal of Climatology 18: 1539-1556), comparisons of values between nearby stations suggested that instrumental changes, combined with locational changes, may have modified the results by as much as 1°C during the 40-year period. Nevertheless, seasonally averaged results indicated an increase over much of the area, of slightly over 1°C/100 years in spring and autumn, slightly less than this in summer. Winter displayed a drying of over 1°C/100 years. When only the 1961-1990 period was considered, the patterns were similar and trends increased by approximately 1-2°C/100 years, except in autumn, which displayed a slight drying. Analyses for specific stations indicated periods of both increasing and decreasing Td, the change between them varying with observation hour. No single change point was common over a wide area, although January commonly indicated maximum values early in the period in the east and west, and much later in the north-central portion. Rates of increase were generally higher in daytime than at night, especially in summer. Investigation of the inter-decadal differences in dew point, as a function of wind conditions, indicated that changes during calm conditions were commonly similar in magnitude to that of the overall average changes, suggesting an important role for the local hydrologic cycle in driving changes. Other inter-decadal changes could be attributed to the changes in the frequency and moisture content of invading air-streams. This was particularly clear for the changes in north-south flow in the interior.

  19. Automatic continuous dew point measurement in combustion gases

    Energy Technology Data Exchange (ETDEWEB)

    Fehler, D.

    1986-08-01

    Low exhaust temperatures serve to minimize energy consumption in combustion systems. This requires accurate, continuous measurement of exhaust condensation. An automatic dew point meter for continuous operation is described. The principle of measurement, the design of the measuring system, and practical aspects of operation are discussed.

  20. Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method

    Directory of Open Access Journals (Sweden)

    Ningning Lin

    2016-11-01

    Full Text Available In this paper, the influence of temperature on quartz crystal microbalance (QCM sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of −3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability.

  1. Note: A dual-channel sensor for dew point measurement based on quartz crystal microbalance

    Science.gov (United States)

    Li, Ning; Meng, Xiaofeng; Nie, Jing

    2017-05-01

    A new sensor with dual-channel was designed for eliminating the temperature effect on the frequency measurement of the quartz crystal microbalance (QCM) in dew point detection. The sensor uses active temperature control, produces condensation on the surface of QCM, and then detects the dew point. Both the single-channel and the dual-channel methods were conducted based on the device. The measurement error of the single-channel method was less than 0.5 °C at the dew point range of -2 °C-10 °C while the dual-channel was 0.3 °C. The results showed that the dual-channel method was able to eliminate the temperature effect and yield better measurement accuracy.

  2. A MEMS-based super fast dew point hygrometer—construction and medical applications

    International Nuclear Information System (INIS)

    Jachowicz, Ryszard S; Weremczuk, Jerzy; Paczesny, Daniel; Tarapata, Grzegorz

    2009-01-01

    The paper shows how MEMS (micro-electro-mechanical system) technology and a modified principle of fast temperature control (by heat injection instead of careful control of cooling) can considerably improve the dynamic parameters of dew point hygrometers. Some aspects of MEMS-type integrated sensor construction and technology, whole measurement system design, the control algorithm to run the system as well as empirical dynamic parameters from the tests are discussed too. The hygrometer can easily obtain five to six measurements per second with an uncertainty of less than 0.3 K. The meter range is between −10 °C and 40 °C dew point. In the second part of the paper (section 2), two different successful applications in medicine based on fast humidity measurements have been discussed. Some specific constructions of these super fast dew point hygrometers based on a MEMS sensor as well as limited empirical results from clinical tests have been reported too

  3. A MEMS-based super fast dew point hygrometer—construction and medical applications

    Science.gov (United States)

    Jachowicz, Ryszard S.; Weremczuk, Jerzy; Paczesny, Daniel; Tarapata, Grzegorz

    2009-12-01

    The paper shows how MEMS (micro-electro-mechanical system) technology and a modified principle of fast temperature control (by heat injection instead of careful control of cooling) can considerably improve the dynamic parameters of dew point hygrometers. Some aspects of MEMS-type integrated sensor construction and technology, whole measurement system design, the control algorithm to run the system as well as empirical dynamic parameters from the tests are discussed too. The hygrometer can easily obtain five to six measurements per second with an uncertainty of less than 0.3 K. The meter range is between -10 °C and 40 °C dew point. In the second part of the paper (section 2), two different successful applications in medicine based on fast humidity measurements have been discussed. Some specific constructions of these super fast dew point hygrometers based on a MEMS sensor as well as limited empirical results from clinical tests have been reported too.

  4. Investigation of a novel dew point indirect evaporative air conditioning system for buildings

    OpenAIRE

    Duan, Zhiyin

    2011-01-01

    This study aims to improve the performance of existing indirect evaporative coolers. A new dew point indirect evaporative cooler with counter-current heat/mass exchanger was developed in this research by optimal design, material selection, numerical simulation, experimental investigations and economic, environmental, regional acceptance analysis. A new dew point heat/mass exchanger using a counter-current flow pattern was designed by numerical simulation in terms of material, structure, g...

  5. Improvement of lithium chloride dew-point hygrometer for direct reading and controlling of relative humidity

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.Z.; Chu, Y.

    1986-01-01

    The lithium chloride dew-point hygrometer has many advantages over other types of hygrometers. However, it only reads and controls the dew-point temperature of air instead of the relative humidity, which is more important in industry, agriculture, food storage, and hygiene. This paper describes a new hygrometer which is based on the same principle as the lithium chloride dew-point hygrometer, but it can read and control the relative humidity directly. The instrument is quick in response and the ranges of temperature and relative humidity are quite large. Its accuracy is normally within 3% RH and its precision is within 2% RH.

  6. Numerical study of a novel counter-flow heat and mass exchanger for dew point evaporative cooling

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, X.; Riffat, S.B. [School of the Built Environment, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom); Li, J.M. [Department of Thermal Engineering, Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Tsinghua University, Beijing 100084 (China)

    2008-10-15

    The paper presents numerical investigation of a novel counter-flow heat and mass exchanger used in the indirect evaporative dew point cooling systems, a potential alternative to the conventional mechanical compression air conditioning systems. Numeric simulation was carried out to optimise the geometrical sizes and operating conditions of the exchanger in order to enhance the cooling (dew point and wet bulb) effectiveness of the exchanger and maximise the energy efficiency of the dew point cooling system. The results of the simulations indicated that cooling (dew point and wet bulb) effectiveness and energy efficiency are largely dependent on the dimensions of the airflow passages, air velocity and working-to-intake-air ratio, and less dependent on the temperature of the feed water. It is recommended that exchanger intake air velocity should be controlled to a value below 0.3-0.5 m/s; height of air passage (channel) should be set to 6 mm or below and the length of the passage should be 200 time the height; the working-to-intake-air ratio should be around 0.4. Under the UK summer design condition, i.e., 28{sup o}C of dry bulb temperature, 20{sup o}C of wet bulb temperature and 16{sup o}C of dew point temperature, the exchanger can achieve wet-bulb effectiveness of up to 1.3 and dew-point effectiveness of up to 0.9. (author)

  7. High Response Dew Point Measurement System for a Supersonic Wind Tunnel

    Science.gov (United States)

    Blumenthal, Philip Z.

    1996-01-01

    A new high response on-line measurement system has been developed to continuously display and record the air stream dew point in the NASA Lewis 10 x 10 supersonic wind tunnel. Previous instruments suffered from such problems as very slow response, erratic readings, and high susceptibility to contamination. The system operates over the entire pressure level range of the 10 x 10 SWT, from less than 2 psia to 45 psia, without the need for a vacuum pump to provide sample flow. The system speeds up tunnel testing, provides large savings in tunnel power costs and provides the dew point input for the data-reduction subroutines which calculate test section conditions.

  8. The measurement of tiny dew droplets at the initial deposition stage and dew point using a phase-shift interference microscope

    Science.gov (United States)

    Shigeaki, Matsumoto

    2003-12-01

    The shape of a dew droplet deposited on the mirror surface of a copper plate was measured accurately using an interference microscope that employed a phase-shift technique. The microscope was constructed by adding a piezoelectric transducer to an interference microscope. A simple method that uses a conventional speaker horn and an optical fibre cable was used to depress any speckle noise. The shape of a dew droplet deposited at dew point on the plate surface with average roughness of 0.1 µm was measured with an accuracy of ± 3 nm. The mass of a tiny dew droplet could be determined from the volume of its shape and was of the order of 10-9 g. The total mass of a dew droplet deposited per unit area and the deposition velocity under a gentle wind were also obtained in a similar way. The total mass was of the order of 10-5 g cm-2 at the beginning of deposition and the deposition velocity ranged from 1 × 10-5 to 6 × 10-5 g cm-2 min-1 at room temperature.

  9. Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

    Science.gov (United States)

    Arkin, C.; Gillespie, Stacey; Ratzel, Christopher

    2010-01-01

    A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

  10. Determination of dew point in natural gas; Determinacion del punto de rocio en el gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Avila Calzada, S.; Marco Martinez, G.; Montenegro Soto, S. [ENAGAS (Spain)

    1995-07-01

    The natural gas can contain water and heavy hydrocarbons very dangerous for the equipments and the pipes. This is the reason of the importance of dew point. The value of this dew point is fixed in the supply contract conditions. This article studies the different evaluation methods, pointing out the advantages and disadvantages (Author)

  11. Global Validation of MODIS Atmospheric Profile-Derived Near-Surface Air Temperature and Dew Point Estimates

    Science.gov (United States)

    Famiglietti, C.; Fisher, J.; Halverson, G. H.

    2017-12-01

    This study validates a method of remote sensing near-surface meteorology that vertically interpolates MODIS atmospheric profiles to surface pressure level. The extraction of air temperature and dew point observations at a two-meter reference height from 2001 to 2014 yields global moderate- to fine-resolution near-surface temperature distributions that are compared to geographically and temporally corresponding measurements from 114 ground meteorological stations distributed worldwide. This analysis is the first robust, large-scale validation of the MODIS-derived near-surface air temperature and dew point estimates, both of which serve as key inputs in models of energy, water, and carbon exchange between the land surface and the atmosphere. Results show strong linear correlations between remotely sensed and in-situ near-surface air temperature measurements (R2 = 0.89), as well as between dew point observations (R2 = 0.77). Performance is relatively uniform across climate zones. The extension of mean climate-wise percent errors to the entire remote sensing dataset allows for the determination of MODIS air temperature and dew point uncertainties on a global scale.

  12. Effects of dew point on selective oxidation of TRIP steels containing Si, Mn, and B

    Science.gov (United States)

    Lee, Suk-Kyu; Kim, Jong-Sang; Choi, Jin-Won; Kang, Namhyun; Cho, Kyung-Mox

    2011-04-01

    The selective oxidation of Si, Mn, and B on TRIP steel surfaces is a widely known phenomenon that occurs during heat treatment. However, the relationship between oxide formation and the annealing factors is not completely understood. This study examines the effect of the annealing conditions (dew point and annealing temperature) on oxide formation. A low dew point of -40 °C leads to the formation of Si-based oxides on the surface. A high dew point of -20 °C changes the oxide type to Mn-based oxides because the formation of Si oxides on the surface is suppressed by internal oxidation. Mn-based oxides exhibit superior wettability due to aluminothermic reduction during galvanizing.

  13. Fuzzy logic prediction of dew point pressure of selected Iranian gas condensate reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Nowroozi, Saeed [Shahid Bahonar Univ. of Kerman (Iran); Iranian Offshore Oil Company (I.O.O.C.) (Iran); Ranjbar, Mohammad; Hashemipour, Hassan; Schaffie, Mahin [Shahid Bahonar Univ. of Kerman (Iran)

    2009-12-15

    The experimental determination of dew point pressure in a window PVT cell is often difficult especially in the case of lean retrograde gas condensate. Besides all statistical, graphical and experimental methods, the fuzzy logic method can be useful and more reliable for estimation of reservoir properties. Fuzzy logic can overcome uncertainty existent in many reservoir properties. Complexity, non-linearity and vagueness are some reservoir parameter characteristics, which can be propagated simply by fuzzy logic. The fuzzy logic dew point pressure modeling system used in this study is a multi input single output (MISO) Mamdani system. The model was developed using experimentally constant volume depletion (CVD) measured samples of some Iranian fields. The performance of the model is compared against the performance of some of the most accurate and general correlations for dew point pressure calculation. Results show that this novel method is more accurate and reliable with an average absolute deviation of 1.33% and 2.68% for developing and checking, respectively. (orig.)

  14. Methods for the analysis of SO/sub 2/, SO/sub 3/ and H/sub 2/S in flue gas and the calculation of the acid dew point

    Energy Technology Data Exchange (ETDEWEB)

    Albertyn, C.H.

    1986-02-01

    Methods are given for the analysis of SO/sub 2/, SO/sub 3/, and H/sub 2/S in flue gas. Two methods are described for the determination of SO/sub 2/. The method to be used depends on whether or not H/sub 2/S is present in the gas stream. An equation for the calculation of acid dew point is given as well.

  15. Densimetry for the Quantification of Sorption Phenomena on Nonporous Media Near the Dew Point of Fluid Mixtures.

    Science.gov (United States)

    Richter, Markus; McLinden, Mark O

    2017-07-21

    Phase equilibria of fluid mixtures are important in numerous industrial applications and are, thus, a major focus of thermophysical property research. Improved data, particularly along the dew line, are needed to improve model predictions. Here we present experimental results utilizing highly accurate densimetry to quantify the effects of sorption and capillary condensation, which exert a distorting influence on measured properties near the dew line. We investigate the (pressure, density, temperature, composition) behaviour of binary (CH 4  + C 3 H 8 ) and (Ar + CO 2 ) mixtures over the temperature range from (248.15 to 273.15) K starting at low pressures and increasing in pressure towards the dew point along isotherms. Three distinct regions are observed: (1) minor sorption effects in micropores at low pressures; (2) capillary condensation followed by wetting in macro-scale surface scratches beginning approximately 2% below the dew-point pressure; (3) bulk condensation. We hypothesize that the true dew point lies within the second region.

  16. Phase-equilibria for design of coal-gasification processes: dew points of hot gases containing condensible tars. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Prausnitz, J.M.

    1980-05-01

    This research is concerned with the fundamental physical chemistry and thermodynamics of condensation of tars (dew points) from the vapor phase at advanced temperatures and pressures. Fundamental quantitative understanding of dew points is important for rational design of heat exchangers to recover sensible heat from hot, tar-containing gases that are produced in coal gasification. This report includes essentially six contributions toward establishing the desired understanding: (1) Characterization of Coal Tars for Dew-Point Calculations; (2) Fugacity Coefficients for Dew-Point Calculations in Coal-Gasification Process Design; (3) Vapor Pressures of High-Molecular-Weight Hydrocarbons; (4) Estimation of Vapor Pressures of High-Boiling Fractions in Liquefied Fossil Fuels Containing Heteroatoms Nitrogen or Sulfur; and (5) Vapor Pressures of Heavy Liquid Hydrocarbons by a Group-Contribution Method.

  17. The Influence of Air Temperature on the Dew Point Temperature in ...

    African Journals Online (AJOL)

    ADOWIE PERE

    done to determine the influence and effect of temperature on other climatic environmental ... Key words: Air Temperature, Dew point temperature, Weather, Climate, Influence. Weather ... humidity, clouds and atmospheric pressure. Its.

  18. A Calibration Facility for Dew Point in Air up to 1 MPa

    Science.gov (United States)

    Carroll, P. A.; Bell, S. A.; Stevens, M.

    2015-12-01

    The provision of primary dew-point standards for humidified air and nitrogen at atmospheric pressure is well established, and measurement traceability to these standards provides confidence in a vast number of air humidity measurements. However, hygrometers are used industrially at a wide range of pressures. Both the performance of hygrometers and the properties of humid gases are known to vary with gas pressure. The pressure-dependence of gas non-ideality for air-water mixtures (water-vapor enhancement factor) is well enough known at moderate pressures, but there remains a need to characterize hygrometers at the pressure of use. To address this, a humidity calibration capability of wider scope is under development at the UK National Physical Laboratory (NPL). As an initial stage in the development of this capability, a humidity standard generating air or nitrogen in the dew-point range from -60° C to +10° C, at pressures up to 1 MPa (10 bar) has been validated for the calibration of hygrometers. The expanded uncertainty of the dew-point generator in this range with a coverage factor k= 2 is ± 0.07° C.

  19. Applicability of a desiccant dew-point cooling system independent of external water sources

    DEFF Research Database (Denmark)

    Bellemo, Lorenzo; Elmegaard, Brian; Kærn, Martin Ryhl

    2015-01-01

    The applicability of a technical solution for making desiccant cooling systems independent of external water sources is investigated. Water is produced by condensing the desorbed water vapour in a closed regeneration circuit. Desorbed water recovery is applied to a desiccant dew-point cooling...... system, which includes a desiccant wheel and a dew point cooler. The system is simulated during the summer period in the Mediterranean climate of Rome and it results completely independent of external water sources. The seasonal thermal COP drops 8% in comparison to the open regeneration circuit solution...

  20. The New LMK Primary Standard for Dew-Point Sensor Calibration: Evaluation of the High-Range Saturator Efficiency

    Science.gov (United States)

    Hudoklin, Domen; Drnovšek, Janko

    2008-10-01

    In the field of hygrometry, a primary dew-point standard can be realized according to several proven principles, such as single-pressure (1-P), two-pressure (2-P), or divided flow. Different realizations have been introduced by various national laboratories, each resulting in a stand-alone complex generation system. Recent trends in generator design favor the single-pressure principle without recirculation because it promises theoretically lower uncertainty and because it avoids problems regarding the leak tightness of the recirculation. Instead of recirculation, the efficiency of saturation, the key factor, is increased by preconditioning the inlet gas entering the saturator. For preconditioning, a presaturator or purifier is used to bring the dew point of the inlet stream close to the saturator temperature. The purpose of the paper is to identify the minimum requirements for the preconditioning system and the main saturator to assure efficient saturation for the LMK generator. Moreover, the aim is also to find out if the preconditioning system can be avoided despite the rather simple construction of the main saturator. If this proves to be the case, the generator design can be simplified while maintaining an accurate value of the generated dew point. Experiments were carried out within the scope of improving our existing primary generator in the above-ambient dew-point range up to +70°C. These results show the generated dew point is within the measurement uncertainty for any dew-point value of the inlet gas. Thus, the preconditioning subsystem can be avoided, which leads to a simplified generator design.

  1. Investigation of potential factors affecting the measurement of dew point temperature in oil-soaked transformers

    Science.gov (United States)

    Kraus, Adam H.

    Moisture within a transformer's insulation system has been proven to degrade its dielectric strength. When installing a transformer in situ, one method used to calculate the moisture content of the transformer insulation is to measure the dew point temperature of the internal gas volume of the transformer tank. There are two instruments commercially available that are designed for dew point temperature measurement: the Alnor Model 7000 Dewpointer and the Vaisala DRYCAPRTM Hand-Held Dewpoint Meter DM70. Although these instruments perform an identical task, the design technology behind each instrument is vastly different. When the Alnor Dewpointer and Vaisala DM70 instruments are used to measure the dew point of the internal gas volume simultaneously from a pressurized transformer, their differences in dew point measurement have been observed to vary as much as 30 °F. There is minimal scientific research available that focuses on the process of measuring dew point of a gas inside a pressurized transformer, let alone this observed phenomenon. The primary objective of this work was to determine what effect certain factors potentially have on dew point measurements of a transformer's internal gas volume, in hopes of understanding the root cause of this phenomenon. Three factors that were studied include (1) human error, (2) the use of calibrated and out-of-calibration instruments, and (3) the presence of oil vapor gases in the dry air sample, and their subsequent effects on the Q-value of the sampled gas. After completing this portion of testing, none of the selected variables proved to be a direct cause of the observed discrepancies between the two instruments. The secondary objective was to validate the accuracy of each instrument as compared to its respective published range by testing against a known dew point temperature produced by a humidity generator. In a select operating range of -22 °F to -4 °F, both instruments were found to be accurate and within their

  2. A novel method of measuring the concentration of anaesthetic vapours using a dew-point hygrometer.

    Science.gov (United States)

    Wilkes, A R; Mapleson, W W; Mecklenburgh, J S

    1994-02-01

    The Antoine equation relates the saturated vapour pressure of a volatile substance, such as an anaesthetic agent, to the temperature. The measurement of the 'dew-point' of a dry gas mixture containing a volatile anaesthetic agent by a dew-point hygrometer permits the determination of the partial pressure of the anaesthetic agent. The accuracy of this technique is limited only by the accuracy of the Antoine coefficients and of the temperature measurement. Comparing measurements by the dew-point method with measurements by refractometry showed systematic discrepancies up to 0.2% and random discrepancies with SDS up to 0.07% concentration in the 1% to 5% range for three volatile anaesthetics. The systematic discrepancies may be due to errors in available data for the vapour pressures and/or the refractive indices of the anaesthetics.

  3. The influence of dew point during annealing on the power loss of electrical steel sheets

    Energy Technology Data Exchange (ETDEWEB)

    Broddefalk, Arvid [Development and Market Research, Cogent Power Ltd., P.O. Box 201, SE-735 23 Surahammar (Sweden)], E-mail: arvid.broddefalk@sura.se; Jenkins, Keith [Development and Market Research, Cogent Power Ltd., P.O. Box 201, SE-735 23 Surahammar (Sweden); Silk, Nick [Corus RD and T, Swinden Technology Centre, Moorgate Rotherham S60 3AR (United Kingdom); Lindenmo, Magnus [Development and Market Research, Cogent Power Ltd., P.O. Box 201, SE-735 23 Surahammar (Sweden)

    2008-10-15

    Decarburization is a necessary part of the processing of electrical steels if their carbon content is above a certain level. The process is usually carried out in a wet hydrogen-nitrogen atmosphere. Having a high dew point has a negative influence on the power loss, though. This is due to oxidation of the steel, which hinders domain wall motion near the surface. In this study, an increase of the power loss was only observed at a fairly high dew point (>20 deg. C). It was also only at these high dew points where a subsurface oxide layer was observed. The surfaces of samples with and without this layer were etched in steps. The magnetic properties of the etched samples corresponded well with the expected behavior based on GDOES profiles of the samples.

  4. The influence of dew point during annealing on the power loss of electrical steel sheets

    Science.gov (United States)

    Broddefalk, Arvid; Jenkins, Keith; Silk, Nick; Lindenmo, Magnus

    Decarburization is a necessary part of the processing of electrical steels if their carbon content is above a certain level. The process is usually carried out in a wet hydrogen-nitrogen atmosphere. Having a high dew point has a negative influence on the power loss, though. This is due to oxidation of the steel, which hinders domain wall motion near the surface. In this study, an increase of the power loss was only observed at a fairly high dew point (>20 °C). It was also only at these high dew points where a subsurface oxide layer was observed. The surfaces of samples with and without this layer were etched in steps. The magnetic properties of the etched samples corresponded well with the expected behavior based on GDOES profiles of the samples.

  5. Remotely-sensed, nocturnal, dew point correlates with malaria transmission in Southern Province, Zambia: a time-series study.

    Science.gov (United States)

    Nygren, David; Stoyanov, Cristina; Lewold, Clemens; Månsson, Fredrik; Miller, John; Kamanga, Aniset; Shiff, Clive J

    2014-06-13

    Plasmodium falciparum transmission has decreased significantly in Zambia in the last decade. The malaria transmission is influenced by environmental variables. Incorporation of environmental variables in models of malaria transmission likely improves model fit and predicts probable trends in malaria disease. This work is based on the hypothesis that remotely-sensed environmental factors, including nocturnal dew point, are associated with malaria transmission and sustain foci of transmission during the low transmission season in the Southern Province of Zambia. Thirty-eight rural health centres in Southern Province, Zambia were divided into three zones based on transmission patterns. Correlations between weekly malaria cases and remotely-sensed nocturnal dew point, nocturnal land surface temperature as well as vegetation indices and rainfall were evaluated in time-series analyses from 2012 week 19 to 2013 week 36. Zonal as well as clinic-based, multivariate, autoregressive, integrated, moving average (ARIMAX) models implementing environmental variables were developed to model transmission in 2011 week 19 to 2012 week 18 and forecast transmission in 2013 week 37 to week 41. During the dry, low transmission season significantly higher vegetation indices, nocturnal land surface temperature and nocturnal dew point were associated with the areas of higher transmission. Environmental variables improved ARIMAX models. Dew point and normalized differentiated vegetation index were significant predictors and improved all zonal transmission models. In the high-transmission zone, this was also seen for land surface temperature. Clinic models were improved by adding dew point and land surface temperature as well as normalized differentiated vegetation index. The mean average error of prediction for ARIMAX models ranged from 0.7 to 33.5%. Forecasts of malaria incidence were valid for three out of five rural health centres; however, with poor results at the zonal level. In this

  6. Increase in the boiler's performance in terms of the acid dew point temperature: Environmental advantages of replacing fuels

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, J.M.; Pena, F. [Dpto. Maquinas y Motores Termicos, Escuela Tecnica Superior de Ingenieria, Universidad del Pais Vasco/E.H.U., Alameda de Urquijo s/n (48013) Bilbao (Spain)

    2008-05-15

    The aim of air pre-heaters is to raise the temperature of the combustion air in boilers, using heat recovered from the power plant combustion gases. On the one hand, this paper compares the effects of the acid dew point temperature (ADT) on pre-heaters in a reference thermal power plant for two types of fuel, ''fuel No. 2'' and ''low sulphur fuel'' respectively and on the other hand, it shows how a changeover to this latter fuel would increase the useful lifetime of this equipment, reducing this way cost of maintenance due to the considerable decrease in the area exposed to ADT with the subsequent increase in the boiler's performance. (author)

  7. Consistency of the national realization of dew-point temperature using NIS standard humidity generators

    Directory of Open Access Journals (Sweden)

    El-Galil Doaa Abd

    2017-01-01

    Full Text Available A comparison of two standard humidity generators (two-temperature (2-T and one-temperature (1-T generators that are developed by the National Institute for Standards (NIS has been performed using a transfer standard chilled-mirror hygrometer and measurement procedures to realize dew-point temperature Td in the range from −50 °C to 0 °C. The main objective of this comparison was to compare the realizations of dew-point temperature and to establish the level of consistency between the two generators. For a level of consistency between two measurements, it is expressed by the difference between the measured values, m1 − m2, and the expanded pair uncertainty of this difference Up [1]. The comparison measurements revealed dew-point temperature differences of 0.02 °C and 0.07 °C with expanded pair uncertainties of ±0.09 °C and ±0.15 °C.

  8. Study on dew point evaporative cooling system with counter-flow configuration

    International Nuclear Information System (INIS)

    Lin, J.; Thu, K.; Bui, T.D.; Wang, R.Z.; Ng, K.C.; Chua, K.J.

    2016-01-01

    Highlights: • Numerical model for a dew point evaporative cooler verified with experiments. • Saturation point of the working air is independent of the inlet air conditions. • The intensity of cooling capacity and water evaporation are studied. • The overall heat transfer coefficient for the working air is analyzed. • The conditions to achieve sub-wet bulb cooling are examined. - Abstract: Dew point evaporative cooling has great potential as a disruptive process for sensible cooling of air below its entering wet bulb temperature. This paper presents an improved mathematical model for a single-stage dew point evaporative cooler in a counter-flow configuration. Longitudinal heat conduction and mass diffusion of the air streams, channel plate and water film, as well as the temperature difference between the plate and water film, are accounted for in the model. Predictions of the product air temperature are validated using three sets of experimental data within a discrepancy of 4%. The cooler’s heat and mass transfer process is analyzed in terms of its cooling capacity intensity, water evaporation intensity, and overall heat transfer coefficient along the channel. Parametric studies are conducted at different geometric and operating conditions. For the conditions evaluated, the study reveals that (1) the saturation point of the working air occurs at a fixed point regardless of the inlet air conditions, and it is mainly influenced by the working air ratio and channel height; (2) the intensity of the water evaporation approaches a minimum at 0.2 to 0.3 m from the entrance; (3) the wet channel can be separated into two zones, and the overall heat transfer coefficient is above 100 W/(m"2·K) after the temperature of water film becomes higher than the working air temperature.

  9. Development of a neural fuzzy system for advanced prediction of dew point pressure in gas condensate reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Nowroozi, Saeed; Hashemipour, Hasan; Schaffie, Mahin [Department of Chemical Engineering, Shahid Bahonar University of Kerman (Iran); ERC, Shahid Bahonar University of Kerman (Iran); Ranjbar, Mohammad [Department of Mining Engineering, Shahid Bahonar University of Kerman (Iran); ERC, Shahid Bahonar University of Kerman (Iran)

    2009-03-15

    Dew point pressure is one of the most critical quantities for characterizing a gas condensate reservoir. So, accurate determination of this property has been the main challenge in reservoir development and management. The experimental determination of dew point pressure in PVT cell is often difficult especially in case of lean retrograde gas condensate. Empirical correlations and some equations of state can be used to calculate reservoir fluid properties. Empirical correlations do not have ability to reliable duplicate the temperature behavior of constant composition fluids. Equations of state have convergence problem and need to be tuned against some experimental data. Complexity, non-linearity and vagueness are some reservoir parameter characteristic which can be propagated simply by intelligent system. With the advantage of fuzzy sets in knowledge representation and the high capacity of neural nets (NNs) in learning knowledge expressed in data, in this paper a neural fuzzy system(NFS) is proposed to predict dew point pressure of gas condensate reservoir. The model was developed using 110 measurements of dew point pressure. The performance of the model is compared against performance of some of the most accurate and general correlations for dew point pressure calculation. From the results of this study, it can be pointed out that this novel method is more accurate and reliable with the mean square error of 0.058%, 0.074% and 0.044% for training, validation and test processes, respectively. (author)

  10. Validation of a dew-point generator for pressures up to 6 MPa using nitrogen and air

    Science.gov (United States)

    Bosma, R.; Mutter, D.; Peruzzi, A.

    2012-08-01

    A new primary humidity standard was developed at VSL that, in addition to ordinary operation with air and nitrogen at atmospheric pressure, can be operated with other carrier gases such as natural gas at pressures up to 6 MPa and SF6 at pressures up to 1 MPa. The temperature range of the standard is from -80 °C to +20 °C. In this paper, we report the validation of the new primary dew-point generator in the temperature range -41 °C to +5 °C and the pressure range 0.1 MPa to 6 MPa using nitrogen and air. For the validation the flow through the dew-point generator was varied up to 10 l min-1 (at 23 °C and 1013 hPa) and the dew point of the gas entering the generator was varied up to 15 °C above the dew point exiting the generator. The validation results showed that the new generator, over the tested temperature and pressure range, can be used with a standard uncertainty of 0.02 °C frost/dew point. The measurements used for the validation at -41 °C and -20 °C with nitrogen and at +5 °C with air were also used to calculate the enhancement factor at pressures up to 6 MPa. For +5 °C the differences between the measured and literature values were compatible with the respective uncertainties. For -41 °C and -20 °C they were compatible only up to 3 MPa. At 6 MPa a discrepancy was observed.

  11. Evaluation of the dew point cooling technology; Beoordeling technologie dauwpuntskoeling

    Energy Technology Data Exchange (ETDEWEB)

    Bootsveld, N.R.; Afink, J. [TNO Milieu, Energie en Procesinnovatie TNO-MEP, Amersfoort (Netherlands); Uges, P.G.H. (ed.) [Standex Periodieken, Veenendaal (Netherlands)

    2003-01-01

    Results of measurements on an indirect adiabatic dew point cooling system are presented and discussed. The cooling system has been developed by ComfortAir, Raalte, Netherlands. [Dutch] De meetresultaten van door ComfortAir in samenwerking met TNO-MEP uitgevoerde metingen aan een indirect werkende adiabatische dauwpuntkoeler worden gepresenteerd en besproken.

  12. Transport-induced shifts in condensate dew-point and composition in multicomponent systems with chemical reaction

    Science.gov (United States)

    Rosner, D. E.; Nagarajan, R.

    1985-01-01

    Partial heterogeneous condensation phenomena in multicomponent reacting systems are analyzed taking into consideration the chemical element transport phenomena. It is demonstrated that the dew-point surface temperature in chemically reactive systems is not a purely thermodynamic quantity, but is influenced by the multicomponent diffusion and Soret-mass diffusion phenomena. Several distinct dew-points are shown to exist in such systems and, as a result of transport constraints, the 'sharp' locus between two chemically distinct condensates is systematically moved to a difference mainstream composition.

  13. Dew-point hygrometry system for measurement of evaporative water loss in infants.

    Science.gov (United States)

    Ariagno, R L; Glotzbach, S F; Baldwin, R B; Rector, D M; Bowley, S M; Moffat, R J

    1997-03-01

    Evaporation of water from the skin is an important mechanism in thermal homeostasis. Resistance hygrometry, in which the water vapor pressure gradient above the skin surface is calculated, has been the measurement method of choice in the majority of pediatric investigations. However, resistance hygrometry is influenced by changes in ambient conditions such as relative humidity, surface temperature, and convection currents. We have developed a ventilated capsule method that minimized these potential sources of measurement error and that allowed second-by-second, long-term, continuous measurements of evaporative water loss in sleeping infants. Air with a controlled reference humidity (dew-point temperature = 0 degree C) is delivered to a small, lightweight skin capsule and mixed with the vapor on the surface of the skin. The dew point of the resulting mixture is measured by using a chilled mirror dew-point hygrometer. The system indicates leaks, is mobile, and is accurate within 2%, as determined by gravimetric calibration. Examples from a recording of a 13-wk-old full-term infant obtained by using the system give evaporative water loss rates of approximately 0.02 mgH2O.cm-2.min-1 for normothermic baseline conditions and values up to 0.4 mgH2O.cm-2. min-1 when the subject was being warmed. The system is effective for clinical investigations that require dynamic measurements of water loss.

  14. Monthly variations of dew point temperature in the coterminous United States

    Science.gov (United States)

    Robinson, Peter J.

    1998-11-01

    The dew point temperature, Td, data from the surface airways data set of the U.S. National Climatic Data Center were used to develop a basic dew point climatology for the coterminous United States. Quality control procedures were an integral part of the analysis. Daily Td, derived as the average of eight observations at 3-hourly intervals, for 222 stations for the 1961-1990 period were used. The annual and seasonal pattern of average values showed a clear south-north decrease in the eastern portion of the nation, a trend which was most marked in winter. In the west, values decreased inland from the Pacific Coast. Inter-annual variability was generally low when actual mean values were high. A cluster analysis suggested that the area could be divided into six regions, two oriented north-south in the west, four aligned east-west in the area east of the Rocky Mountains. Day-to-day variability was low in all seasons in the two western clusters, but showed a distinct winter maximum in the east. This was explained in broad terms by consideration of air flow regimes, with the Pacific Ocean and the Gulf of Mexico acting as the major moisture sources. Comparison of values for pairs of nearby stations suggested that Td was rather insensitive to local moisture sources. Analysis of the patterns of occurrence of dew points exceeding the 95th percentile threshold indicated that extremes in summer tend to be localized and short-lived, while in winter they are more widespread and persistent.

  15. Use of dew-point hygrometry, direct sweat collection, and measurement of body water losses to determine sweating rates in exercising horses.

    Science.gov (United States)

    Kingston, J K; Geor, R J; McCutcheon, L J

    1997-02-01

    To compare dew-point hygrometry, direct sweat collection, and measurement of body water loss as methods for determination of sweating rate (SR) in exercising horses. 6 exercise-trained Thoroughbreds. SR was measured in 6 horses exercising at 40% of the speed that elicited maximum oxygen consumption for 45 km, with a 15-minute rest at the end of each 15-km phase. Each horse completed 2 exercise trials. Dew-point hygrometry, as a method of local SR determination, was validated in vitro by measurement of rate of evaporative water loss. During exercise, local SR was determined every 10 minutes by the following 2 methods: (1) dew-point hygrometry on the neck and lateral area of the thorax, and (2) on the basis of the volume of sweat collected from a sealed plastic pouch attached to the lateral area of the thorax. Mean whole body SR was calculated from total body water loss incurred during exercise. Evaporation rate measured by use of dew-point hygrometry was significantly correlated (r2 = 0.92) with the actual rate of evaporative water loss. There was a similar pattern of change in SR measured by dew-point hygrometry on the neck and lateral area of the thorax during exercise, with a significantly higher SR on the neck. The SR measured on the thorax by direct sweat collection and by dew-point hygrometry were of similar magnitude. Mean whole body SR calculated from total body water loss was not significantly different from mean whole body SR estimated from direct sweat collection or dew-point hygrometry measurements on the thorax. Dew-point hygrometry and direct sweat collection are useful methods for determination of local SR in horses during prolonged, steady-state exercise in moderate ambient conditions. Both methods of local SR determination provide an accurate estimated of whole body SR.

  16. Sensitive skin at menopause; dew point and electrometric properties of the stratum corneum.

    Science.gov (United States)

    Paquet, F; Piérard-Franchimont, C; Fumal, I; Goffin, V; Paye, M; Piérard, G E

    1998-01-12

    A number of menopausal women experience skin sensitive to various environmental threats. Two panels of 15 menopausal women on or without HRT were compared. We studied the response of their stratum corneum to variations in environmental humidity, either in air or in response to an emollient. Environment dew point and electrometric measurements on the skin were recorded to search for correlations. Data show that the baseline stratum corneum hydration is influenced by the dew point. HRT improves the barrier function of the skin. The use of emollient further extends the improvement in the functional properties of skin in menopausal women. Both HRT and an emollient can counteract in part some of the deleterious effects of cold and dry weather.

  17. Using ANFIS for selection of more relevant parameters to predict dew point temperature

    International Nuclear Information System (INIS)

    Mohammadi, Kasra; Shamshirband, Shahaboddin; Petković, Dalibor; Yee, Por Lip; Mansor, Zulkefli

    2016-01-01

    Highlights: • ANFIS is used to select the most relevant variables for dew point temperature prediction. • Two cities from the central and south central parts of Iran are selected as case studies. • Influence of 5 parameters on dew point temperature is evaluated. • Appropriate selection of input variables has a notable effect on prediction. • Considering the most relevant combination of 2 parameters would be more suitable. - Abstract: In this research work, for the first time, the adaptive neuro fuzzy inference system (ANFIS) is employed to propose an approach for identifying the most significant parameters for prediction of daily dew point temperature (T_d_e_w). The ANFIS process for variable selection is implemented, which includes a number of ways to recognize the parameters offering favorable predictions. According to the physical factors influencing the dew formation, 8 variables of daily minimum, maximum and average air temperatures (T_m_i_n, T_m_a_x and T_a_v_g), relative humidity (R_h), atmospheric pressure (P), water vapor pressure (V_P), sunshine hour (n) and horizontal global solar radiation (H) are considered to investigate their effects on T_d_e_w. The used data include 7 years daily measured data of two Iranian cities located in the central and south central parts of the country. The results indicate that despite climate difference between the considered case studies, for both stations, V_P is the most influential variable while R_h is the least relevant element. Furthermore, the combination of T_m_i_n and V_P is recognized as the most influential set to predict T_d_e_w. The conducted examinations show that there is a remarkable difference between the errors achieved for most and less relevant input parameters, which highlights the importance of appropriate selection of input parameters. The use of more than two inputs may not be advisable and appropriate; thus, considering the most relevant combination of 2 parameters would be more suitable

  18. Multiobjective optimization in Gene Expression Programming for Dew Point

    OpenAIRE

    Shroff, Siddharth; Dabhi, Vipul

    2013-01-01

    The processes occurring in climatic change evolution and their variations play a major role in environmental engineering. Different techniques are used to model the relationship between temperatures, dew point and relative humidity. Gene expression programming is capable of modelling complex realities with great accuracy, allowing, at the same time, the extraction of knowledge from the evolved models compared to other learning algorithms. This research aims to use Gene Expression Programming ...

  19. Determination of the dew point and the frost point below 0 degrees C making use of the beta-ray backscattering and the electric conductivity on the narrow surface of insulated layer.

    Science.gov (United States)

    Matsumoto, S; Kobayashi, H

    1979-10-15

    It is necessary to distinguish between the dew point and the frost point below 0 degrees C. The freezing of the dew and the melting of the frost are respectively detected by the rapid decrease and the increase of the conduction current on the narrow surface of insulated layer made of epoxy, 0.5 mm in width and 10 mm in length, on which the dew deposits. The dew point -9 degrees C and the frost point -8 degrees C in the humidity 21% at the temperature 13 degrees C are clearly distinguished in this method.

  20. New Primary Dew-Point Generators at HMI/FSB-LPM in the Range from -70 °C to +60 °C

    Science.gov (United States)

    Zvizdic, Davor; Heinonen, Martti; Sestan, Danijel

    2012-09-01

    To extend the dew-point range and to improve the uncertainties of the humidity scale realization at HMI/FSB-LPM, new primary low- and high-range dew-point generators were developed and implemented in cooperation with MIKES, in 2009 through EUROMET Project No. 912. The low-range saturator is designed for primary realization of the dew-point temperature scale from -70 °C to + 5 °C, while the high-range saturator covers the range from 1 °C to 60 °C. The system is designed as a single-pressure, single-pass dew-point generator. MIKES designed and constructed both the saturators to be implemented in dew-point calibration systems at LPM. The LPM took care of purchasing and adapting liquid baths, of implementing the temperature and pressure measurement equipment appropriate for use in the systems, and development of gas preparation and flow control systems as well as of the computer-based automated data acquisition. The principle and the design of the generator are described in detail and schematically depicted. The tests were performed at MIKES to investigate how close both the saturators are to an ideal saturator. Results of the tests show that both the saturators are efficient enough for a primary realization of the dew-point temperature scale from -70 °C to + 60 °C, in the specified flow-rate ranges. The estimated standard uncertainties due to the non-ideal saturation efficiency are between 0.02 °C and 0.05 °C.

  1. Hourly predictive Levenberg-Marquardt ANN and multi linear regression models for predicting of dew point temperature

    Science.gov (United States)

    Zounemat-Kermani, Mohammad

    2012-08-01

    In this study, the ability of two models of multi linear regression (MLR) and Levenberg-Marquardt (LM) feed-forward neural network was examined to estimate the hourly dew point temperature. Dew point temperature is the temperature at which water vapor in the air condenses into liquid. This temperature can be useful in estimating meteorological variables such as fog, rain, snow, dew, and evapotranspiration and in investigating agronomical issues as stomatal closure in plants. The availability of hourly records of climatic data (air temperature, relative humidity and pressure) which could be used to predict dew point temperature initiated the practice of modeling. Additionally, the wind vector (wind speed magnitude and direction) and conceptual input of weather condition were employed as other input variables. The three quantitative standard statistical performance evaluation measures, i.e. the root mean squared error, mean absolute error, and absolute logarithmic Nash-Sutcliffe efficiency coefficient ( {| {{{Log}}({{NS}})} |} ) were employed to evaluate the performances of the developed models. The results showed that applying wind vector and weather condition as input vectors along with meteorological variables could slightly increase the ANN and MLR predictive accuracy. The results also revealed that LM-NN was superior to MLR model and the best performance was obtained by considering all potential input variables in terms of different evaluation criteria.

  2. Development of a new densimeter for the combined investigation of dew-point densities and sorption phenomena of fluid mixtures

    Science.gov (United States)

    Moritz, Katharina; Kleinrahm, Reiner; McLinden, Mark O.; Richter, Markus

    2017-12-01

    For the determination of dew-point densities and pressures of fluid mixtures, a new densimeter has been developed. The new apparatus is based on the well-established two-sinker density measurement principle with the additional capability of quantifying sorption effects. In the vicinity of the dew line, such effects cause a change in composition of the gas mixture under study, which can significantly distort accurate density measurements. The new experimental technique enables the accurate measurement of dew-point densities and pressures and the quantification of sorption effects at the same time.

  3. The effect of water contamination on the dew-point temperature scale realization with humidity generators

    Science.gov (United States)

    Vilbaste, M.; Heinonen, M.; Saks, O.; Leito, I.

    2013-08-01

    The purpose of this paper is to study the effect of contaminated water in the context of humidity generators. Investigation of different methods to determine the drop in dew-point temperature due to contamination and experiments on actual contamination rates are reported. Different methods for calculating the dew-point temperature effect from electrical conductivity and density measurements are studied with high-purity water and aqueous solutions of NaCl and LiCl. The outcomes of the calculation methods are compared with the results of direct humidity measurements. The results show that the often applied Raoult's law based calculation method is in good agreement with other methods. For studying actual contamination, water samples were kept in glass, plastic, copper and stainless-steel vessels for up to 13 months to investigate natural ionic and organic contamination in vessels with different wall materials. The amount of ionic contamination was found to be higher in copper and glass vessels than in stainless-steel and plastic vessels. The amount of organic contamination was found to be highest in the plastic vessel. In all the cases, however, the corresponding drop in dew-point temperature due to natural contamination was found to be below 0.1 mK. The largest rate of change of dew-point temperature was 26 µK/month. Thus, if proper cleanness is maintained in a humidity generator the effect of contamination of water in the saturator is insignificant compared with the major uncertainty components even in the most accurate generators today.

  4. Feasibility study of a novel dew point air conditioning system for China building application

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xudong; Yang, Shuang; Duan, Zhiyin; Riffat, Saffa B. [School of the Built Environment, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom)

    2009-09-15

    The paper investigated the feasibility of a novel dew point evaporative cooling for air conditioning of buildings in China regions. The issues involved include analyses of China weather conditions, investigation of availability of water for dew point cooling, and assessment of cooling capacity of the system within various regions of China. It is concluded that the dew point system is suitable for most regions of China, particularly northern and west regions of China where the climate is hot and dry during the summer season. It is less suitable for Guangzhou and Shanghai where climates are hot and humid. However, an air pre-treatment process involving a silica-gel dehumidification will enable the technology to be used for these humid areas. Lower humidity results in a higher difference between the dry bulb and dew point of the air, which benefits the system in terms of enhancing its cooling performance. Tap water has adequate temperature to feed the system for cooling and its consumption rate is in the range 2.6-3 litres per kWh cooling output. The cooling output of the system ranges from 1.1 to 4.3 W per m{sup 3}/h air flow rate in China, depending on the region where the system applies. For a unit with 2 kW of cooling output, the required air volume flow rate varies with its application location and is in the range 570-1800 m{sup 3}/h. For a 50 m{sup 2} building with 60 W/m{sup 2} cooling load, if the system operates at working hours, i.e., 09:00 to 17:00 h, its daily water consumption would be in the range of 60-70 litres. Compared with mild or humid climates, the dry and hot climates need less air volume flow rate and less water. (author)

  5. Measurement and estimation of dew point for SNG. [Comparison of calculated and measured values

    Energy Technology Data Exchange (ETDEWEB)

    Furuyama, Y.

    1974-08-01

    Toho Gas measured and estimated SNG dew points in high-pressure deliveries by calculating the theoretical values by the high-pressure gas-liquid equilibrium theory using the pressure-extrapolation method to reach K = 1, and the BWR method to estimate fugacity, then verifying these values experimentally. The experimental values were measured at 161.7 to 367.5 psi using the conventional static and circulation methods, in addition to a newly developed method consisting of circulating a known composition of gas mixtures, partially freezing them, and monitoring the dew point by observing the droplets on a mirror cooled by blowing liquid nitrogen. Good agreement was found between the calculated and the experimental values.

  6. Estimation of precipitable water from surface dew point temperature

    International Nuclear Information System (INIS)

    Abdel Wahab, M.; Sharif, T.A.

    1991-09-01

    The Reitan (1963) regression equation which is of the form lnw=a+bT d has been examined and tested to estimate precipitable water content from surface dew point temperature at different locations. The study confirms that the slope of this equation (b) remains constant at the value of .0681 deg. C., while the intercept (a) changes rapidly with the latitude. The use of the variable intercept can improve the estimated result by 2%. (author). 6 refs, 4 figs, 3 tabs

  7. A comparative study of compression-expansion type dehumidification systems to achieve low dew point air

    International Nuclear Information System (INIS)

    Moon, Choon; Bansal, Pradeep

    2009-01-01

    This paper presents a theoretical feasibility study of three dehumidification systems to achieve air with dew points down to (-) 40 deg. C. The systems consist of compressors, heat exchangers, expanders and heaters. A thermodynamic model has been developed of the systems to study the effect of the compressor, expander, and heat recovery heat exchanger efficiency as a function of pressure ratio, net required work, quantity of condensed moisture, and system outlet dew point temperature. The analysis has revealed that the selection of a heat recovery heat exchanger is critical for an efficient dehumidification system, where compressor efficiency has the dominant effect on power consumption.

  8. Selective oxidation of dual phase steel after annealing at different dew points

    Science.gov (United States)

    Lins, Vanessa de Freitas Cunha; Madeira, Laureanny; Vilela, Jose Mario Carneiro; Andrade, Margareth Spangler; Buono, Vicente Tadeu Lopes; Guimarães, Juliana Porto; Alvarenga, Evandro de Azevedo

    2011-04-01

    Hot galvanized steels have been extensively used in the automotive industry. Selective oxidation on the steel surface affects the wettability of zinc on steel and the grain orientation of inhibition layer (Fe-Al-Zn alloy) and reduces the iron diffusion to the zinc layer. The aim of this work is to identify and quantify selective oxidation on the surface of a dual phase steel, and an experimental steel with a lower content of manganese, annealed at different dew points. The techniques employed were atomic force microscopy, X-ray photoelectron spectroscopy, and glow discharge optical emission spectroscopy. External selective oxidation was observed for phosphorus on steel surface annealed at 0 °C dp, and for manganese, silicon, and aluminum at a lower dew point. The concentration of manganese was higher on the dual phase steel surface than on the surface of the experimental steel. The concentration of molybdenum on the surface of both steels increased as the depth increased.

  9. Study on dew point evaporative cooling system with counter-flow configuration

    KAUST Repository

    Lin, J.

    2015-12-18

    Dew point evaporative cooling has great potential as a disruptive process for sensible cooling of air below its entering wet bulb temperature. This paper presents an improved mathematical model for a single-stage dew point evaporative cooler in a counter-flow configuration. Longitudinal heat conduction and mass diffusion of the air streams, channel plate and water film, as well as the temperature difference between the plate and water film, are accounted for in the model. Predictions of the product air temperature are validated using three sets of experimental data within a discrepancy of 4%. The cooler’s heat and mass transfer process is analyzed in terms of its cooling capacity intensity, water evaporation intensity, and overall heat transfer coefficient along the channel. Parametric studies are conducted at different geometric and operating conditions. For the conditions evaluated, the study reveals that (1) the saturation point of the working air occurs at a fixed point regardless of the inlet air conditions, and it is mainly influenced by the working air ratio and channel height; (2) the intensity of the water evaporation approaches a minimum at 0.2 to 0.3m from the entrance; (3) the wet channel can be separated into two zones, and the overall heat transfer coefficient is above 100W/(m2·K) after the temperature of water film becomes higher than the working air temperature.

  10. Observed changes in relative humidity and dew point temperature in coastal regions of Iran

    Science.gov (United States)

    Hosseinzadeh Talaee, P.; Sabziparvar, A. A.; Tabari, Hossein

    2012-12-01

    The analysis of trends in hydroclimatic parameters and assessment of their statistical significance have recently received a great concern to clarify whether or not there is an obvious climate change. In the current study, parametric linear regression and nonparametric Mann-Kendall tests were applied for detecting annual and seasonal trends in the relative humidity (RH) and dew point temperature ( T dew) time series at ten coastal weather stations in Iran during 1966-2005. The serial structure of the data was considered, and the significant serial correlations were eliminated using the trend-free pre-whitening method. The results showed that annual RH increased by 1.03 and 0.28 %/decade at the northern and southern coastal regions of the country, respectively, while annual T dew increased by 0.29 and 0.15°C per decade at the northern and southern regions, respectively. The significant trends were frequent in the T dew series, but they were observed only at 2 out of the 50 RH series. The results showed that the difference between the results of the parametric and nonparametric tests was small, although the parametric test detected larger significant trends in the RH and T dew time series. Furthermore, the differences between the results of the trend tests were not related to the normality of the statistical distribution.

  11. The dew point temperature as a criterion for optimizing the operating conditions of proton exchange membrane fuel cells

    DEFF Research Database (Denmark)

    Berning, Torsten

    2012-01-01

    In this article an analytical method to calculate the dew point temperatures of the anode and cathode exit gas streams of a proton exchange membrane fuel cell is developed. The results of these calculations are used to create diagrams that show the dew point temperatures as function of the operat...... for conventional flow field plates. The diagrams presented here are created for completely dry inlet gases, but they can be easily corrected for a nonzero inlet relative humidity....

  12. Sensitivity of a soil-plant-atmosphere model to changes in air temperature, dew point temperature, and solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Luxmoore, R.J. (Oak Ridge National Lab.,TN); Stolzy, J.L.; Holdeman, J.T.

    1981-01-01

    Air temperature, dew point temperature and solar radiation were independently varied in an hourly soil-plant-atmosphere model in a sensitivity analysis of these parameters. Results suggested that evapotranspiration in eastern Tennessee is limited more by meteorological conditions that determine the vapor-pressure gradient than by the necessary energy to vaporize water within foliage. Transpiration and soil water drainage were very sensitive to changes in air and dew point temperature and to solar radiation under low atmospheric vapor-pressure deficit conditions associated with reduced air temperature. Leaf water potential and stomatal conductance were reduced under conditions having high evapotranspiration. Representative air and dew point temperature input data for a particular application are necessary for satisfactory results, whereas irradiation may be less well characterized for applications with high atmospheric vapor-pressure deficit. The effects of a general rise in atmospheric temperature on forest water budgets are discussed.

  13. Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments

    Science.gov (United States)

    Zvizdic, D.; Heinonen, M.; Sestan, D.

    2015-08-01

    The aim of this paper is to describe the evaluation process of the performance of the low-range saturator (LRS), when exposed to two different thermal environments. The examined saturator was designed, built, and tested at MIKES (Centre for Metrology and Accreditation, Finland), and then transported to the Laboratory for Process Measurement (LPM) in Croatia, where it was implemented in a new dew-point calibration system. The saturator works on a single-pressure-single-pass generation principle in the dew/frost-point temperature range between and . The purpose of the various tests performed at MIKES was to examine the efficiency and non-ideality of the saturator. As a test bath facility in Croatia differs from the one used in Finland, the same tests were repeated at LPM, and the effects of different thermal conditions on saturator performance were examined. Thermometers, pressure gauges, an air preparation system, and water for filling the saturator at LPM were also different than those used at MIKES. Results obtained by both laboratories indicate that the efficiency of the examined saturator was not affected either by the thermal conditions under which it was tested or by equipment used for the tests. Both laboratories concluded that LRS is efficient enough for a primary realization of the dew/frost-point temperature scale in the range from to , with flow rates between and . It is also shown that a considerable difference of the pre-saturator efficiency, indicated by two laboratories, did not have influence to the overall performance of the saturator. The results of the research are presented in graphical and tabular forms. This paper also gives a brief description of the design and operation principle of the investigated low-range saturator.

  14. Unsteady-state analysis of a counter-flow dew point evaporative cooling system

    KAUST Repository

    Lin, J.

    2016-07-19

    Understanding the dynamic behavior of the dew point evaporative cooler is crucial in achieving efficient cooling for real applications. This paper details the development of a transient model for a counter-flow dew point evaporative cooling system. The transient model approaching steady conditions agreed well with the steady state model. Additionally, it is able to accurately predict the experimental data within 4.3% discrepancy. The transient responses of the cooling system were investigated under different inlet air conditions. Temporal temperature and humidity profiles were analyzed for different transient and step responses. The key findings from this study include: (1) the response trend and settling time is markedly dependent on the inlet air temperature, humidity and velocity; (2) the settling time of the transient response ranges from 50 s to 300 s when the system operates under different inlet conditions; and (3) the average transient wet bulb effectiveness (1.00–1.06) of the system is observed to be higher than the steady state wet bulb effectiveness (1.01) for our range of study. © 2016 Elsevier Ltd

  15. Natural gas treatment: Simultaneous water and hydrocarbon-dew point-control

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, T. (Solvay Catalysts GmbH, Hannover (Germany)); Rennemann, D. (Solvay Catalysts GmbH, Hannover (Germany)); Schulz, T. (Solvay Catalysts GmbH, Hannover (Germany))

    1993-10-01

    Natural gas is a multicomponent mixture of hydrocarbons. The condensation behavior of such mixtures is different from single component systems. The so-called retrograde behavior leads to the observations that saturated vapor (dew point curve) and saturated liquid curve (bubble point curve) are not identical. Between both is a region of saturated phases which even can exist above the critical point. Following this behaviour it is possible that condensation might occur at pressure decrease or at temperature increase, respectively. This phenomenon is undesired in natural gas pipeline networks. Selective removal of higher hydrocarbons by the means of adsorption can change the phase behavior in such a way that condensation does not occur at temperatures and pressures specified for gas distribution. (orig.)

  16. Draught regulator with control flap lowers dew point, keeps stacks dry

    Energy Technology Data Exchange (ETDEWEB)

    Dreizler, U.; Dreizler, W.

    1982-11-30

    Draught regulators for auxiliary air are particularly important in older stacks operated with new boilers and burners. Owing to better ventilation during burner operation and standstill, the dew point of flue gases will be lowered so that water vapour condensation will be prevented. Postfitting of draught regulators will also help in stacks already damaged by condensation water. The draught regulator has a control flap for better control of auxiliary air supply.

  17. Simultaneous measurements of formaldehyde and nitrous acid in dews and gas phase in the atmosphere of Santiago, Chile

    Science.gov (United States)

    Rubio, María A.; Lissi, Eduardo; Villena, Guillermo; Elshorbany, Y. F.; Kleffmann, Jörg; Kurtenbach, Ralf; Wiesen, Peter

    2009-12-01

    The amounts of formaldehyde and nitrous acid (HONO) in gas phase and dews of Santiago de Chile were simultaneously measured. Formaldehyde concentrations values in the liquid phase (dews) correlate fairly well with those in the gaseous phase and are even higher than those expected from gas-dew equilibrium. On the other hand, nitrite concentrations in dews were considerably smaller (ca. 15 times) than those expected from the gas-phase concentrations. This under-saturation is attributed to diffusion limitations due to the relatively large HONO solubility. In agreement with this, under-saturation increases with the rate of dew formation and the pH of the collected waters, factors that should increase the rate of gas to liquid HONO transfer required to reach equilibrium.

  18. Wärtsilä turbocharger wash and dew point controller integration

    OpenAIRE

    Perälä, Antti

    2013-01-01

    There are two separate control cabinets used in Wärtsilä marine solutions, Turbocharger Wash Control and the Dew Point Control. The cabinets contain similar PLCs with I/O-cards needed in the system and touch screen for monitoring and controlling purposes. The purpose of the thesis was to find and implement a solution for integration of the control cabinets. The advantages of the integration are savings in material, space in the engine room and amount of work. The aim of the project was to cre...

  19. Effect of dew point on the formation of surface oxides of twinning-induced plasticity steel

    International Nuclear Information System (INIS)

    Kim, Yunkyum; Lee, Joonho; Shin, Kwang-Soo; Jeon, Sun-Ho; Chin, Kwang-Geun

    2014-01-01

    The surface oxides of twinning-induced plasticity (TWIP) steel annealed at 800 °C for 43 s were investigated using transmission electron microscopy. During the annealing process, the oxygen potential was controlled by adjusting the dew point in a 15%H 2 –N 2 gas atmosphere. It was found that the type of surface oxides formed and the thickness of the oxide layer were determined by the dew point. In a gas mixture with a dew point of − 20 °C, a MnO layer with a thickness of ∼ 100 nm was formed uniformly on the steel surface. Under the MnO layer, a MnAl 2 O 4 layer with a thickness of ∼ 15 nm was formed with small Mn 2 SiO 4 particles that measured ∼ 70 nm in diameter. Approximately 500 nm below the MnAl 2 O 4 layer, Al 2 O 3 was formed at the grain boundaries. On the other hand, in a gas mixture with a dew point of − 40 °C, a MnAl 2 O 4 layer with a thickness of ∼ 5 nm was formed on most parts of the surface. On some parts of the surface, Mn 2 SiO 4 particles were formed irregularly up to a thickness of ∼ 50 nm. Approximately 200 nm below the MnAl 2 O 4 layer, Al 2 O 3 was found at the grain boundaries. Thermodynamic calculations were performed to explain the experimental results. The calculations showed that when a O2 > ∼ 1.26 × 10 −28 , MnO, MnAl 2 O 4 , and Mn 2 SiO 4 can be formed together, and the major oxide is MnO. When a O2 is in the range of 1.26 × 10 −28 –2.51 × 10 −31 , MnO is not stable but MnAl 2 O 4 is the major oxide. When a O2 < ∼ 2.51 × 10 −31 , only Al 2 O 3 is stable. Consequently, the effective activity of oxygen is considered the dominant factor in determining the type and shape of surface oxides of TWIP steel. - Highlights: • The surface oxides of TWIP steel annealed at 800 °C were investigated using TEM. • The surface oxides were determined by the dew point during the annealing process. • The activity of oxygen is the major factor determining the oxides of TWIP steel

  20. An automatic dew-point hygrometer making use of beta-ray backscattering

    International Nuclear Information System (INIS)

    Matsumoto, Sigeaki; Kobayashi, Hisanobu

    1981-01-01

    A proportional control system was employed on this hygrometer. The hygrometer was used in a box in which the temperature and the humidity were constantly regulated. The range of measured dew-point was from -26 0 C to 60 0 C in the atmospheric temperature of 0 0 C to 60 0 C, that was the relative humidity of 12% to 100%, and the accuracy of the measurement was +-1 0 C. (author)

  1. Investigation on the Energy Saving Potential of Using a Novel Dew Point Cooling System in Data Centres

    Directory of Open Access Journals (Sweden)

    Yin Bi

    2017-10-01

    Full Text Available Abstract: Information technology (IT has brought significant changes in people’s lives. As an important part of the IT industry, data centres (DCs have been rapidly growing in both the number and size over the past 40 years. Around 30% to 40% of electricity consumption in DCs is used for space cooling, thus leading to very inefficient DC operation. To identify ways to reduce the energy consumption for space cooling and increase the energy efficiency of DCs’ operation, a dedicated investigation into the energy usage in DCs has been undertaken and a novel high performance dew point cooling system was introduced into a DC operational scheme. Based on the cooling load in DCs, a case study was carried out to evaluate the energy consumptions and energy usage effectiveness when using the novel dew point cooling system in different scales of DCs in various climates. It was found that by using the novel dew point cooling system, for 10 typical climates a DC can have a much lower power usage effectiveness (PUE of 1.10 to 1.22 compared to that of 1.7 to 3.7 by using existing traditional cooling systems, leading to significantly increased energy efficiency of the DC operation. In addition, the energy performance by managing the cooling air supply at the different levels in DCs, i.e., room, row and rack level, was simulated by using a dynamic computer model. It was found that cooling air supply at rack level can provide a higher energy efficiency in DCs. Based on the above work, the energy saving potential in DCs was conducted by comparing DCs using an the novel dew point cooling system and the optimum management scheme for the cooling air supply to that using traditional air cooling systems and the same supply air management. Annual electricity consumptions for the two cases were given. It was found that by using the novel dew point cooling system and optimum management system for the cooling air supply, an 87.7~91.6% electricity consumption saving for

  2. EFFECT OF DEW POINT OF ATMOSPHERE OF CGL’S ANNEALING FURNACES ON THE QUALITY OF GA COATING ON BAKE HARDENABLE STEEL

    Directory of Open Access Journals (Sweden)

    Juliana Porto Guimarães

    2013-10-01

    Full Text Available The strip steel surface condition after continuous annealing of strip is extremely important to the quality of galvannealed coating (GA. The presence of oxides or precipitated can affect the reactions at the coating/substrate interface and decrease the zinc wettability on the steel surface, leading to various defects in the final product. To avoid oxidation of the material during continuous annealing, a protective atmosphere is used in the furnaces. Despite this atmosphere, it is possible the selective oxidation or precipitation of second phase particles, being the dew point of atmosphere one of the leading factors to reduce this occurrence. This study aims to evaluate the effect of the dew point on the quality of GA coatings applied to a bake hardenable steel. The continuous annealing under dew points of –60°C, 30°C and 0°C, as well as hot dip galvanizing, were performed in a Hot Dip Process Simulator. It is found that the dew point has a decisive influence on the amount, distribution and type of oxides formed, and the condition of –30°C provided the coating with less failures and better adhesion.

  3. Study of the influence of the cool-down speed at the dew-point level of the readings of the dew-point temperature; Untersuchungen zum Einfluss der Abkuehlgeschwindigkeit am Taupunktspiegel auf Messwerte der Taupunkttemperatur

    Energy Technology Data Exchange (ETDEWEB)

    Bogoya, J.D. [Univ. Nacional de Colombia (Colombia); Mueller, C. [Inst. fuer Technische Thermodynamik und Kaeltetechnik, Univ. Karlsruhe (Germany); Oellrich, L.R. [Inst. fuer Technische Thermodynamik und Kaeltetechnik, Univ. Karlsruhe (Germany)

    1995-09-01

    The impact of the cool-down speed at the dew-point mirror on the behaviour of the readings of dew-point temperature of nitrogen-water mixtures has been investigated with the focus on mixtures with low water content. For this purpose a commercial dew-point mirror was equipped with a refrigerating device in order to cool the mirror surface. Moreover a data acquisition system was connected for the measurement of the rates of cooling. Via a control valve in the refrigerant cycle rates of cooling of about 1 to 35 C/min could be chosen. With a saturation system saturation conditions could be varied in the pressure range from 5 to 90 bar and in the temperature range from +10 to -15 C. The measuring instrument was continuously supplied with the gas mixture. The measurements were carried out under constant volume flow of the carrier gas. The results are discussed. (orig.) [Deutsch] Der Einfluss der Abkuehlgeschwindigkeit am Taupunktspiegel auf die Lage der Messwerte der Taupunkttemperaturen von Stickstoff/Wasser-Gemischen wurde speziell im Bereich niedriger Wassergehalte untersucht. Dazu wurde ein kommerzieller Taupunktspiegel zur Kuehlung der Spiegeloberflaeche mit einer Kaeltemaschine ausgestattet und eine Messwerterfassung, mit der Abkuehlgeschwindigkeiten ermittelt werden konnte, angeschlossen. Ueber ein Regelventil im Kaeltemittelkreislauf konnten Abkuehlgeschwindigkeiten von ca. 1 bis 35 C/min eingestellt werden. Ueber eine Saettigungsanlage wurden Saettigungsbedingungen im Druckbereich von 5 bis 90 bar und im Temperaturbereich von +10 bis -15 C variiert und das Messgeraet kontinuierlich mit Gasgemisch versorgt. Die Messungen wurden bei konstantem Volumenstrom des Traegergases durchgefuehrt. Die Messergebisse werden diskutiert. (orig.)

  4. Development of Bioclimatic Design Tool for Oman Using Dry Bulb and Dew Point Temperatures Open Database

    Directory of Open Access Journals (Sweden)

    Nasser Al-Azri

    2017-06-01

    Full Text Available Bioclimatic charts are used by engineers and architects in implementing passive cooling systems and architectural optimization with respect to natural air conditioning. Conventionally, the development of these charts is based on the availability of typical meteorological year which requires a record of meteorological data that are rarely available in sufficient amounts. Bioclimatic charts in Oman were developed earlier by the authors for limited locations based on the available typical meteorological years. Using dry bulb and dew point temperatures only, bioclimatic charts are developed for Adam, Buraimi, Ibra, Muscat, Nizwa, Rustaq, Saiq, Salalah, Suhar and Sur. These charts are better representative of bioclimatic trends since their development is mainly based on the relevant parameters, namely dry bulb temperature and dew point.

  5. Estimation of precipitable water at different locations using surface dew-point

    Science.gov (United States)

    Abdel Wahab, M.; Sharif, T. A.

    1995-09-01

    The Reitan (1963) regression equation of the form ln w = a + bT d has been examined and tested to estimate precipitable water vapor content from the surface dew point temperature at different locations. The results of this study indicate that the slope b of the above equation has a constant value of 0.0681, while the intercept a changes rapidly with latitude. The use of the variable intercept technique can improve the estimated result by about 2%.

  6. Effect of dew point on the formation of surface oxides of twinning-induced plasticity steel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yunkyum [Department of Materials Science and Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136–713 (Korea, Republic of); Lee, Joonho, E-mail: joonholee@korea.ac.kr [Department of Materials Science and Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136–713 (Korea, Republic of); Shin, Kwang-Soo [Research Institute of Industrial Science and Technology, Pohang 790–600 (Korea, Republic of); Jeon, Sun-Ho; Chin, Kwang-Geun [POSCO Technical Research Laboratories, Gwangyang 545–090 (Korea, Republic of)

    2014-03-01

    The surface oxides of twinning-induced plasticity (TWIP) steel annealed at 800 °C for 43 s were investigated using transmission electron microscopy. During the annealing process, the oxygen potential was controlled by adjusting the dew point in a 15%H{sub 2}–N{sub 2} gas atmosphere. It was found that the type of surface oxides formed and the thickness of the oxide layer were determined by the dew point. In a gas mixture with a dew point of − 20 °C, a MnO layer with a thickness of ∼ 100 nm was formed uniformly on the steel surface. Under the MnO layer, a MnAl{sub 2}O{sub 4} layer with a thickness of ∼ 15 nm was formed with small Mn{sub 2}SiO{sub 4} particles that measured ∼ 70 nm in diameter. Approximately 500 nm below the MnAl{sub 2}O{sub 4} layer, Al{sub 2}O{sub 3} was formed at the grain boundaries. On the other hand, in a gas mixture with a dew point of − 40 °C, a MnAl{sub 2}O{sub 4} layer with a thickness of ∼ 5 nm was formed on most parts of the surface. On some parts of the surface, Mn{sub 2}SiO{sub 4} particles were formed irregularly up to a thickness of ∼ 50 nm. Approximately 200 nm below the MnAl{sub 2}O{sub 4} layer, Al{sub 2}O{sub 3} was found at the grain boundaries. Thermodynamic calculations were performed to explain the experimental results. The calculations showed that when a{sub O2} > ∼ 1.26 × 10{sup −28}, MnO, MnAl{sub 2}O{sub 4}, and Mn{sub 2}SiO{sub 4} can be formed together, and the major oxide is MnO. When a{sub O2} is in the range of 1.26 × 10{sup −28}–2.51 × 10{sup −31}, MnO is not stable but MnAl{sub 2}O{sub 4} is the major oxide. When a{sub O2} < ∼ 2.51 × 10{sup −31}, only Al{sub 2}O{sub 3} is stable. Consequently, the effective activity of oxygen is considered the dominant factor in determining the type and shape of surface oxides of TWIP steel. - Highlights: • The surface oxides of TWIP steel annealed at 800 °C were investigated using TEM. • The surface oxides were determined by the dew point

  7. Development of ultra low dew-point clean air generator; Cho tei roten seijo kuki hassei sochi no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, H.; Okamura, N. [Takasago thermal Engineering Co., Ltd., Kanagawa (Japan)

    2000-05-10

    To reduce the manufacturing cost of semiconductors, some systems have been proposed that use a cheap and high purity Clean Dry Air (CDA). CDA can reduce process step such as wafer cleaning, because CDA flow in stocker prevents the wafer surface from adsorbing of moisture and organic impurities. We have already optimized a two-stage rotary dehumidifier and have conducted a study of methods for cheaply manufacturing air that has a low dew-point of -70 degree C to -50 degree C. We have further developed the method in which a dry dehumidifier is used, and developed an ultra low dew-point air generator. The air generator is a three-stage rotary dehumidifier in which a further stage is added to the two-stage rotary dehumidifier. The main component of the rotors is metal silicate. The air generator can supply dry air with a dew-point of -110 degree C. or less, in which the concentration in all gaseous contaminants is far below 1 ppb. We made a trial calculation of the manufacturing cost, and an average cost of 0.25 yen/m{sup 3} was obtained. (author)

  8. Experimental study on dew point corrosion characteristics of the heating surface in a 65 t/h biomass-fired circulating fluidized bed boiler

    International Nuclear Information System (INIS)

    Wang, Yungang; Ma, Haidong; Liang, Zhiyuan; Chen, Heng; Zhao, Qinxin; Jin, Xin

    2016-01-01

    Highlights: • Dew point corrosion and ash deposit tests in a biomass-fired boiler were performed. • The XRD, XRF and SEM methods were used to analyze corrosion samples. • The deposits were made up of ash deposit layer, coupling layer and corrosion layer. • The metal matrix simultaneously confronted chlorine corrosion and oxygen corrosion. - Abstract: The dew point corrosion characteristics of the heating surface in a 65 t/h biomass-fired circulating fluidized bed (CFB) boiler were experimentally studied. The cross-sectional morphology and composition of the ash deposition were analyzed by scanning electron microscope (SEM), X-ray diffraction (XRD) and X-ray fluorescence spectrum (XRF), respectively. The results showed that the test tube surface was covered by ash deposit layer, coupling layer and corrosion layer. The ash deposit layer and the coupling layer were prone to spall off together. The coupling layer consists of partial ash and corrosion products. The corrosion layer was mainly composed of chlorides (FeCl_3, FeCl_2, and FeOCl) and oxides (FeOOH, Fe_2O_3). With the increase of the tube wall temperature, the corrosion depth decreased dramatically and the dew point corrosion was alleviated efficiently. The metal matrix simultaneously suffered from chlorine corrosion and oxygen corrosion. As the tube wall temperature was above water dew point, the main corrosion mode was oxygen corrosion. As the tube wall temperature was below water dew point, the main corrosion mode was chlorine corrosion.

  9. Development of the High-Temperature Dew-Point Generator Over the Past 15 Years

    Science.gov (United States)

    Bosma, R.; Nielsen, J.; Peruzzi, A.

    2017-10-01

    At VSL a humidity generator was designed and constructed in the early 1990s. This generator was of the re-circulating-single-pressure type. Over the years, the generator has been thoroughly revised and several critical components have been replaced. Among others the pre-saturator and the change from re-circulation to single-pass mode. Validating experiments showed that the range of the new setup could be extended from 70 {°}C to 95 {°}C dew-point temperature, and the last modification allows an uncertainty of 0.048 {°}C (k = 2) at the maximum temperature. In 2009 the setup was used in the Euramet-T-K8 humidity intercomparison at temperatures up to 95 {°}C. In the period from 2003 to 2015, four state-of-the-art chilled mirror hygrometers were regularly calibrated with the generator. One of these was also calibrated with the primary dew-point standards of several other European National Metrology Institutes, which made it possible to link the VSL generator to the generators used in these institutes. An analysis of the results of these calibrations shows an agreement in calibration capabilities within 0.01 {°}C with PTB and NPL.

  10. Application of a two-sinker densimeter for phase-equilibrium measurements: A new technique for the detection of dew points and measurements on the (methane + propane) system

    International Nuclear Information System (INIS)

    McLinden, Mark O.; Richter, Markus

    2016-01-01

    Highlights: • A new technique for detecting dew points in fluid mixtures is described. • The method makes use of a two-sinker densimeter. • The technique is based on a quantitative measurement of sample mass adsorbed onto the surface of the densimeter sinkers. • The dew-point density and dew-point pressure are determined with low uncertainty. • The method is applied to the (methane + propane) system and compared to traditional methods. - Abstract: We explore a novel method for determining the dew-point density and dew-point pressure of fluid mixtures and compare it to traditional methods. The (p, ρ, T, x) behavior of three (methane + propane) mixtures was investigated with a two-sinker magnetic suspension densimeter over the temperature range of (248.15–293.15) K; the measurements extended from low pressures into the two-phase region. The compositions of the gravimetrically prepared mixtures were (0.74977, 0.50688, and 0.26579) mole fraction methane. We analyzed isothermal data by: (1) a “traditional” analysis of the intersection of a virial fit of the (p vs. ρ) data in the single-phase region with a linear fit of the data in the two-phase region; and (2) an analysis of the adsorbed mass on the sinker surfaces. We compared these to a traditional isochoric experiment. We conclude that the “adsorbed mass” analysis of an isothermal experiment provides an accurate determination of the dew-point temperature, pressure, and density. However, a two-sinker densimeter is required.

  11. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    Science.gov (United States)

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  12. KEY COMPARISON: Final report of APMP.T-K6 (original name APMP-IC-1-97): Comparison of humidity measurements using a dew point meter as a transfer standard

    Science.gov (United States)

    Li, Wang; Takahashi, C.; Hussain, F.; Hong, Yi; Nham, H. S.; Chan, K. H.; Lee, L. T.; Chahine, K.

    2007-01-01

    This APMP key comparison of humidity measurements using a dew point meter as a transfer standard was carried out among eight national metrology institutes from February 1999 to January 2001. The NMC/SPRING, Singapore was the pilot laboratory and a chilled mirror dew point meter offered by NMIJ was used as a transfer standard. The transfer standard was calibrated by each participating institute against local humidity standards in terms of frost and dew point temperature. Each institute selected its frost/dew point temperature calibration points within the range from -70 °C to 20 °C frost/dew point with 5 °C step. The majority of participating institutes measured from -60 °C to 20 °C frost/dew point and a simple mean evaluation was performed in this range. The differences between the institute values and the simple means for all participating institutes are within two standard deviations from the mean values. Bilateral equivalence was analysed in terms of pair difference and single parameter Quantified Demonstrated Equivalence. The results are presented in the report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. Smart textile plasmonic fiber dew sensors.

    Science.gov (United States)

    Esmaeilzadeh, Hamid; Rivard, Maxime; Arzi, Ezatollah; Légaré, François; Hassani, Alireza

    2015-06-01

    We propose a novel Surface Plasmon Resonance (SPR)-based sensor that detects dew formation in optical fiber-based smart textiles. The proposed SPR sensor facilitates the observation of two phenomena: condensation of moisture and evaporation of water molecules in air. This sensor detects dew formation in less than 0.25 s, and determines dew point temperature with an accuracy of 4%. It can be used to monitor water layer depth changes during dew formation and evaporation in the range of a plasmon depth probe, i.e., 250 nm, with a resolution of 7 nm. Further, it facilitates estimation of the relative humidity of a medium over a dynamic range of 30% to 70% by measuring the evaporation time via the plasmon depth probe.

  14. [An automatic dew-point hygrometer making use of beta-ray backscattering (author's transl)].

    Science.gov (United States)

    Matsumoto, S; Kobayashi, H

    1981-04-01

    A proportional control system was employed on this hygrometer. The hygrometer was used in a box in which the temperature and the humidity were constantly regulated. The range of measured dew-point was from -26 degrees C to 60 degrees C in the atmospheric temperature of 0 degree C to 60 degrees C, that was the relative humidity of 12% to 100%, and the accuracy of the measurement was +/- 1 degree C.

  15. Pipeline drying using dehumidified air with low dew point temperature

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Syed Younus; Gandhidasan, P.; Al-Farayedhi, A.A. [King Fahd Univ. of Petroleum and Minerals, Mechanical Engineering Dept., Dhahran (Saudi Arabia)

    1998-05-01

    The presence of humidity may be detrimental to the operation of pipelines transporting natural gas or other petroleum products. In particular conditions water solidifies or reacts chemically with hydrocarbons, forming hydrates. Such crystalline substances may cause obstruction of the lines and damage the equipment of the relevant facilities. A procedure for predicting the performance of drying a pipeline using dehumidified air with a low dew point is described in this paper. The mathematical model estimates the time required for the complete removal of moisture in the pipeline for the given operating conditions with simplified assumptions. The governing equations are solved analytically as well as numerically and the results are briefly discussed in the paper. (Author)

  16. Future PMPs Estimation in Korea under AR5 RCP 8.5 Climate Change Scenario: Focus on Dew Point Temperature Change

    Science.gov (United States)

    Okjeong, Lee; Sangdan, Kim

    2016-04-01

    According to future climate change scenarios, future temperature is expected to increase gradually. Therefore, it is necessary to reflect the effects of these climate changes to predict Probable Maximum Precipitations (PMPs). In this presentation, PMPs will be estimated with future dew point temperature change. After selecting 174 major storm events from 1981 to 2005, new PMPs will be proposed with respect to storm areas (25, 100, 225, 400, 900, 2,025, 4,900, 10,000 and 19,600 km2) and storm durations (1, 2, 4, 6, 8, 12, 18, 24, 48 and 72 hours) using the Korea hydro-meteorological method. Also, orographic transposition factor will be applied in place of the conventional terrain impact factor which has been used in previous Korean PMPs estimation reports. After estimating dew point temperature using future temperature and representative humidity information under the Korea Meteorological Administration AR5 RCP 8.5, changes in the PMPs under dew point temperature change will be investigated by comparison with present and future PMPs. This research was supported by a grant(14AWMP-B082564-01) from Advanced Water Management Research Program funded by Ministry of Land, Infrastructure and Transport of Korean government.

  17. Dew point, internal gas pressure, and chemical composition of the gas within the free volume of DWPF canistered waste forms

    International Nuclear Information System (INIS)

    Harbour, J.R.; Herman, D.T.; Crump, S.; Miller, T.J.; McIntosh, J.

    1996-01-01

    The Defense Waste Processing Facility (DWPF) produced 55 canistered waste forms containing simulated waste glass during the four Waste Qualification campaigns of the DWPF Startup Test Program. Testing of the gas within the free volume of these canisters for dew point, internal gas pressure, and chemical composition was performed as part of a continuing effort to demonstrate compliance with the Waste Acceptance Product Specifications. Results are presented for six glass-filled canisters. The dew points within the canisters met the acceptance criterion of < 20 degrees C for all six canisters. Factors influencing the magnitude of the dew point are presented. The chemical composition of the free volume gas was indistinguishable from air for all six canisters. Hence, no foreign materials were present in the gas phase of these canisters. The internal gas pressures within the sealed canisters were < 1 atm at 25 degrees C for all six canisters which readily met the acceptance criterion of an internal gas pressure of less than 1.5 atm at 25 degrees C. These results provided the evidence required to demonstrate compliance with the Waste Acceptance Product Specifications

  18. Analysis of points of dew and contents of humidity of gassy mixtures N2-H2 O and CH4 H2 O

    International Nuclear Information System (INIS)

    Bedoya M, D; Muller, C; Oellrich, L R

    1995-01-01

    The actual knowledge of the exact water content in saturated gas mixtures still is incomplete, especially in the high pressure and low temperature region. Hence, dew point measurements with nitrogen - water and methane-water mixtures were performed; at pressures of 3 and 6 MPa and temperatures from 258 K to 288 K. The dew points were determined with the dew point mirror method and the water content by means of the Karl-Fischer-titration. The experimental values were compared to correlations from the literature. The approach by Sharma-Campbell resulted in the best description of the system nitrogen - water. For temperatures below 273 K the assumption of ideal behavior proved to be sufficient for the system methane-water, whereas for temperatures above 273 K calculations with the two-parameter corresponding states principle in combination with a fugacity correction turned out to be the best

  19. Multi-channel fiber optic dew and humidity sensor

    Science.gov (United States)

    Limodehi, Hamid E.; Mozafari, Morteza; Amiri, Hesam; Légaré, François

    2018-03-01

    In this article, we introduce a multi-channel fiber optic dew and humidity sensor which works using a novel method based on relation between surface plasmon resonance (SPR) and water vapor condensation. The proposed sensor can instantly detect moisture or dew formation through its fiber optic channels, separately situated in different places. It enables to simultaneously measure the ambient Relative Humidity (RH) and dew point temperature of several environments with accuracy of 5%.

  20. A dew point signaller for conservation of works of art.

    Science.gov (United States)

    Camuffo, D; Valcher, S

    1986-03-01

    All works of art, from paintings, frescoes, sculptures, to monuments and buildings, are affected by diurnal and seasonal variations of the local microclimate, which induce interactions with the environmental atmosphere. Heat and vapour exchanges cause fluxes of heat and mass between the surface and the atmosphere, and may favour the agressivity of environmental pollutants. Condensation-evaporation cycles are recognized as being very important processes which adversely affect the life-time of the work of art. The need to control the microclimate or to stop condensation processes has been resolved by means of a dew-point signaller especially designed to overcome this problem. This paper discusses the characteristics of this device as well as the environmental philosophy which should be followed when conserving works of art.

  1. Test and evaluation of the Fort St. Vrain dew point moisture monitor system

    International Nuclear Information System (INIS)

    Block, G.A.; Del Bene, J.V. Jr.; Gitterman, M.; Hastings, G.A.; Hawkins, W.M.; Hinz, R.F.; McCue, D.E.; Swanson, L.L.; Vavrina, J.; Zwetzig, G.B.

    1975-01-01

    Descriptions are given of the Fort St. Vrain Dew Point Moisture Monitor (DPMM) System; the bases for the DPMM system response time requirements for safety related functions at the required reactor operating conditions; the results and evaluation of recent testing which measured the performance of the current system at simulated operating conditions; predicted response times for reactor power operation from 0 to 100 percent and a modification to provide improved response times for low-load and plant start-up conditions

  2. Measurement Uncertainty of Dew-Point Temperature in a Two-Pressure Humidity Generator

    Science.gov (United States)

    Martins, L. Lages; Ribeiro, A. Silva; Alves e Sousa, J.; Forbes, Alistair B.

    2012-09-01

    This article describes the measurement uncertainty evaluation of the dew-point temperature when using a two-pressure humidity generator as a reference standard. The estimation of the dew-point temperature involves the solution of a non-linear equation for which iterative solution techniques, such as the Newton-Raphson method, are required. Previous studies have already been carried out using the GUM method and the Monte Carlo method but have not discussed the impact of the approximate numerical method used to provide the temperature estimation. One of the aims of this article is to take this approximation into account. Following the guidelines presented in the GUM Supplement 1, two alternative approaches can be developed: the forward measurement uncertainty propagation by the Monte Carlo method when using the Newton-Raphson numerical procedure; and the inverse measurement uncertainty propagation by Bayesian inference, based on prior available information regarding the usual dispersion of values obtained by the calibration process. The measurement uncertainties obtained using these two methods can be compared with previous results. Other relevant issues concerning this research are the broad application to measurements that require hygrometric conditions obtained from two-pressure humidity generators and, also, the ability to provide a solution that can be applied to similar iterative models. The research also studied the factors influencing both the use of the Monte Carlo method (such as the seed value and the convergence parameter) and the inverse uncertainty propagation using Bayesian inference (such as the pre-assigned tolerance, prior estimate, and standard deviation) in terms of their accuracy and adequacy.

  3. Development of a Dew-Point Generator for Gases Other than Air and Nitrogen and Pressures up to 6 MPa

    Science.gov (United States)

    Bosma, R.; Peruzzi, A.

    2012-09-01

    A new primary humidity standard is currently being developed at VSL that, in addition to ordinary operation with air and nitrogen at atmospheric pressure, can be operated also with special carrier gases such as natural gas and SF6 and at pressures up to 6 MPa. In this paper, the design and construction of this new primary dew-point generator and the preliminary tests performed on the generator are reported. The results of the first efficiency tests, performed for the dew-point temperature range from -50 °C to 20°C, for pressures up to 0.7MPa and for carrier gas flow rates up to 4L· min-1, showed satisfactory generator performance when used in the single-pass mode, i.e., with no recirculation of the carrier gas.

  4. Technology assessment of dew point cooling; Beoordeling technologie dauwpuntskoeling

    Energy Technology Data Exchange (ETDEWEB)

    Uges, P.G.H. [Koudetechnisch Centrum, Nijmegen (Netherlands); Reinder, T.M.

    2003-03-01

    Results of measurements on an indirect adiabatic dew point cooling system are presented and discussed. The cooling system has been developed by OxyCom (formerly ComfortAir), Raalte, Netherlands. [Dutch] De techniek van dauwpuntskoeling is gebaseerd op bet principe van indirecte verdamping van water in een secundair circuit, waarbij geen extra vocht aan de te koelen luchtstroom wordt toegevoegd en waarmee luchttemperaturen worden bereikt die net boven het dauwpunt liggen en dus onder de natteboltemperatuur. Dauwpuntskoeling is een technische ontwikkeling met goede toekomstverwachtingen. Voorzover bekend zijn er tot op heden geen meetgegevens gepubliceerd met een dergelijke indirect werkende koeler. Dit artikel geeft de meetresultaten weer van een door OxyCorn in samenwerking met TNO-MEP uitgevoerd meetprogramma. Dit artikel is gebaseerd op de TNO-MEP rapportage met als auteurs N.R. Bootsveld en J. Afink en heeft eerder in het blad Koude en Luchtbehandeling, januari 2003, gestaan.

  5. Characterization of Emericella nidulans RodA and DewA hydrophobin mutants

    DEFF Research Database (Denmark)

    Jensen, Britt Guillaume; Nielsen, Jakob Blæsbjerg; Pedersen, Mona Højgaard

    hydrophobins RodA and DewA. Individual knock-out mutants rodAΔ, dewAΔ and the double deletion strain rodAΔdewAΔ were constructed. Furthermore, two strains containing a point mutation in the first of the cysteines of RodA (rodA-C57G), where one was coupled to the dewA deletion, were included. The reference...... strain (NID1) and dewAΔ displayed green conidia. However, rodAΔ and rodAΔdewAΔ showed a dark green/brown conidial pigmentation, while rodA-C57G and rodAC57G dewAΔ displayed lighter brown conidia. rodAΔ and rodAΔdewAΔ displayed a higher degree of hülle cells compared to the moderate amount observed...... for NID1 and dewAΔ, while rodA-C57G and rodA-C57G dewAΔ displayed a low number of hülle cells. NID1 and dewAΔ conidia were dispersed as spore chains. rodAΔ, rodAΔdewAΔ, rodA-C57G and rodA-C57G dewAΔ spores were associated in large clumps, where the conidia seemed to adhere to one another. The largest...

  6. Urban dew and rain in Paris, France: Occurrence and physico-chemical characteristics

    Science.gov (United States)

    Beysens, D.; Mongruel, A.; Acker, K.

    2017-06-01

    This paper summarizes one year (April 2011 to March 2012) measurements on planar condensing surfaces of dew and rain events and related physico-chemical characteristics in the urban environment of Paris (city center). Yearly collected water was 3.48 mm for dew (63 events) and 593 mm for rain (146 events). The latter value compares well with rain data (547 mm and 107 events) collected within 12 km at Paris-Orly airport. An estimation of dew yield based on meteo data gives 2.35 mm and 74 events, to be compared with 17.11 mm and 196 events at Paris-Orly. These differences highlight the large reduction in dew events and dew yields in an urban area as compared to a close rural-like area. This reduction is not due to a sky view reduction but to heat island that increases air temperature and decreases relative humidity. Analysis of dew (34) and rain (77) samples were done concerning pH, electrical conductivity (EC), major anions and cations as well as selected trace metals and other minor ions. Mean pH values are found similar for both, dew (6.5) and rain (6.1), rain being slightly more acidic than dew. The mean dew total ionic content (TIC 1.8 meq/l) and EC value (124 μS/cm) are about four times that of rain (0.45 meq/l; 35 μS/cm), meaning that total dissolved solids in dew is nearly four times that in rain. Sulfate and nitrate are the most acidifying components, calcium the most neutralizing constituent with ratio of mean total acidity/total alkalinity comparable for dew and rain ( 0.9). Sulfate and nitrate have mainly anthropogenic sources, whereas chloride and magnesium are mostly connected with marine air masses. Dew is a considerable factor of wet deposition of pollutants; dew and rain ion concentrations, however, meet the WHO requirements for drinking water.

  7. Dew Frequency across the NEON Network from Infrared Radiometry

    Science.gov (United States)

    Ritter, F.; Berkelhammer, M. B.; Beysens, D.

    2017-12-01

    The surface energy budget is more difficult to close at night because of the absence of strong atmospheric turbulence, central in the eddy-covariance calculations. One approach to assessing the direction of the nocturnal latent heat flux is through studying the frequency and magnitude of dew formation in different ecosystems. However, most former dew studies on dew dynamics utilized artificial surfaces to collect dew, and did not have access to the surface temperature of natural surfaces in an ecosystem to provide a continuous whole-plot approach to constrain dew formation. Hourly in-situ measurements recently made available by the National Ecological Observatory Network (NEON) of the radiometric surface temperature and the meteorological variables provide a unique opportunity to make continuous estimates of dew formation across 19 ecosystems (9 grasslands and 10 forests) at the plot-scale. Here, dew duration was calculated for each night based on the difference between the surface temperature and the dew point temperature of the air. The results from this analysis show that dew duration is limited by wind speed during the night, with a maximum dew yield at 1.1 m/s and no dew occurrence when the wind speed exceeds 7 m/s. This observation is consistent with previous studies but has been expanded here across multiple biomes to produce a well-defined turbulent limit on dew formation. The sensitivity of dew to wind speed arises because of the exhaustion of the water vapor supply close to the surface of the leaf at very low wind speed, and because the enhanced thermal exchange between the air and the surface counteracts dewfall at high wind speed. This well-defined wind speed limit that persists across sites and seasons could help to estimate the surface energy budget at night by constraining the latent heat flux.

  8. Effects of leaf hair points of a desert moss on water retention and dew formation: implications for desiccation tolerance.

    Science.gov (United States)

    Tao, Ye; Zhang, Yuan Ming

    2012-05-01

    Leaf hair points (LHPs) are important morphological structures in many desiccation-tolerant mosses, but study of their functions has been limited. A desert moss, Syntrichia caninervis, was chosen for examination of the ecological effects of LHPs on water retention and dew formation at individual and population (patch) levels. Although LHPs were only 4.77% of shoot weight, they were able to increase absolute water content (AWC) by 24.87%. The AWC of samples with LHPs was always greater than for those without LHPs during dehydration. The accumulative evaporation ratio (AER) showed an opposite trend. AWC, evaporation ratio and AER of shoots with LHPs took 20 min longer to reach a completely dehydrated state than shoots without LHPs. At the population level, dew formation on moss crusts with LHPs was faster than on crusts without LHPs, and the former had higher daily and total dew amounts. LHPs were able to improve dew amounts on crusts by 10.26%. Following three simulated rainfall events (1, 3 and 6 mm), AERs from crusts with LHPs were always lower than from crusts without LHPs. LHPs can therefore significantly delay and reduce evaporation. We confirm that LHPs are important desiccation-tolerant features of S. caninervis at both individual and population levels. LHPs greatly aid moss crusts in adapting to arid conditions.

  9. STUDY ON THE DEW POINT TEMPERATURE IN AREAS COVERED BY COLLUVIAL MESOVOID SHALLOW SUBSTRATUM (CRYSTALLINE SCHISTS SCREE IN THE LEAOTA MOUNTAINS, 2014

    Directory of Open Access Journals (Sweden)

    Magdalin Leonard Dorobăţ

    2015-12-01

    Full Text Available This paper present and discussed the results of the monitoring of the dew point values, recorded in October and November 2014, in an ecological station in the Leaota Mountains. In this station, two polls were located in areas covered by colluvial mesovoid shallow substratum (MSS formed by epi- and mesometamorphic crystalline schists. In the ecological stations we located in the Leaota Mountains, almost always we found condensation on the walls of the polls tubes placed at different depths. Most often in spring or autumn or in other cold days, the dew point is more revealing regarding the recording actual amount of moisture in the air, than the relative humidity indicator. This work is part of a larger project that seeks correlations between ecological factors (humidity, temperature and dew point registered in various types of screes (limestone and crystalline schists and some zoocenotic components (invertebrates. This research aim to know the importance of mesovoid shallow substratum for invertebrates or small vertebrates fauna and represents a premiere for Leaota Mountains, not only regarding the continuous monitoring of some ecologic factors of these types of ecosystems (MSS, rarely researched even at global level, and also regarding the inventory of the invertebrate fauna in scree for these mountains.

  10. Investigation of the Equivalence of National Dew-Point Temperature Realizations in the -50 °C to + 20 °C Range

    Science.gov (United States)

    Heinonen, Martti; Anagnostou, Miltiadis; Bell, Stephanie; Stevens, Mark; Benyon, Robert; Bergerud, Reidun Anita; Bojkovski, Jovan; Bosma, Rien; Nielsen, Jan; Böse, Norbert; Cromwell, Plunkett; Kartal Dogan, Aliye; Aytekin, Seda; Uytun, Ali; Fernicola, Vito; Flakiewicz, Krzysztof; Blanquart, Bertrand; Hudoklin, Domen; Jacobson, Per; Kentved, Anders; Lóio, Isabel; Mamontov, George; Masarykova, Alexandra; Mitter, Helmut; Mnguni, Regina; Otych, Jan; Steiner, Anton; Szilágyi Zsófia, Nagyné; Zvizdic, Davor

    2012-09-01

    In the field of humidity quantities, the first CIPM key comparison, CCT-K6 is at its end. The corresponding European regional key comparison, EUROMET.T-K6, was completed in early 2008, about 4 years after the starting initial measurements in the project. In total, 24 NMIs from different countries took part in the comparison. This number includes 22 EURAMET countries, and Russia and South Africa. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was carried out in three parallel loops, each with two chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. It is shown that the standard uncertainty due to the long-term instability was smaller than 0.008 °C in all loops. The standard uncertainties due to links between the loops were found to be smaller than 0.025 °C at -50 °C and 0.010 °C elsewhere. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from the EURAMET comparison reference values (ERV). Taking into account 16 different primary dew-point realizations and 8 secondary realizations, the results demonstrate the equivalence of a large number of laboratories at an uncertainty level that is better than achieved in other multilateral comparisons so far in the humidity field.

  11. Prediction of the critical point and the dew- and bubble-point curves fo natural gases. Tennen gas no rinkaiten oyobi roten futten kyokusen no suisan

    Energy Technology Data Exchange (ETDEWEB)

    Endo, T. (Hitachi, Ltd., Tokyo (Japan)); Arai, D.; Uematsu, M. (Keio University, Tokyo (Japan). Faculty of Science and Technology)

    1993-02-25

    Related to the natural gas transport by pipeline, etc., the critical point, dew point and bubble point of natural gas were presumed by calculation through equation of state for determining the exact thermophysical values. The natural gas is multi-component mixed fluid which is represented by methane as a representative component. It considerably differs in composition by its place of origin. Because the conventional method was complicated in process for thermodynamically determining the most stable composition of phases, algorithm of phasic equilibrium was applied by the equation of state which used the discrimination method by Nitta, et al. for the therodynamic stability of phases. The method by Michelsen was applied to the flash calculation, and figuration of both dew point and bubble point curves, while that by Heidemann, et al. was done to the critical point calculation. Peng-Robinson's was applied to an equation of state. To start the calculation, the constant of seven two-component systems the main component of which was methane was determined as a function of temperature based on the actually measured gas/liquid equilibrium value. Then, possibility of calculatively presuming the thermophysical values was shown through comparison of the actually measured values with those obtained by applying the present method to the above systems. Finally, the presumption was made for the natural gas which differed in place of origin. 17 refs., 15 figs., 2 tabs.

  12. Intercomparison of the Dew-Point Temperature Realizations at LPM and MIKES in the Range from -70 °C to + 20 ° C

    Science.gov (United States)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2012-09-01

    The first European humidity key comparison EURAMET-T.K6 was completed in 2008, and it covered the dew-point temperature range from -50 °C to + 20 °C. Both LPM and MIKES participated in the comparison, but a new low dew-point generator was introduced at LPM as a result of progress in the EUROMET P912 project. To extend the range of available comparison evidence down to -70 °C and to study the validity of improved uncertainties of LPM, a bilateral comparison was carried out between LPM and MIKES in 2009-2010. The applied comparison procedure was similar to that applied in EURAMET-T.K6. However, only one transfer standard was used instead of two units and the measurement point -70 °C was added in the measurement scheme. The results show that the bilateral equivalence between LPM and MIKES is between (0.00 ± 0.06) °C and (0.02 ± 0.08) °C in the range from -50 °C to + 20 °C and (0.01 ± 0.10) °C at -70 °C. Using MIKES results as the link to the EURAMET.T-K6, it is shown that the difference between the results obtained with the new LPM dew-point temperature standard and the EURAMET Comparison Reference Values is between (-0.02 ± 0.08) °C at 20 °C and (+ 0.02 ± 0.07) ° C at -50 °C.

  13. Characteristics of Sulfuric Acid Condensation on Cylinder Liners of Large Two-Stroke Marine Engines

    DEFF Research Database (Denmark)

    Cordtz, Rasmus Lage; Mayer, Stefan; Schramm, Jesper

    . Formation of corrosive sulfuric acid in the cylinder gas is modeled with a cali-brated engine model that incorporates a detailed sulfur reaction mechanism. Condensation of sulfuric acid follows the analogy between heat and mass transfer. Average bulk gas acid dew points are calculated by applying two......-phase thermochemistry of the binary H2O-H2SO4 system. Max dew points of typically more than 200 °C are modeled close to max pressure and variations in terms of operating conditions are not large. However small increments of the dew point provided by e.g. the residual gas fraction, operating pressure, sulfur content...

  14. Selective Oxidation of a 0.1C-6Mn-2Si Third Generation Advanced High-Strength Steel During Dew-Point Controlled Annealing

    Science.gov (United States)

    Pourmajidian, Maedeh; McDermid, Joseph R.

    2018-03-01

    The present study investigates the selective oxidation of a 0.1C-6Mn-2Si medium-Mn advanced high-strength steel during austenization annealing heat treatments as a function of process atmosphere oxygen partial pressure and annealing time. It was determined that the surface oxide growth kinetics followed a parabolic rate law with the minimum rate belonging to the lowest oxygen partial pressure atmosphere at a dew point of 223 K (- 50 °C). The chemistry of the surface and subsurface oxides was studied using STEM + EELS on the sample cross sections, and it was found that the surface oxides formed under the 223 K (- 50 °C) dew-point atmosphere consisted of a layered configuration of SiO2, MnSiO3, and MnO, while in the case of the higher pO2 process atmospheres, only MnO was detected at the surface. Consistent with the Wagner calculations, it was shown that the transition to internal oxidation for Mn occurred under the 243 K (- 30 °C) and 278 K (+ 5 °C) dew-point atmospheres. However, the predictions of the external to internal oxidation for Si using the Wagner model did not correlate well with the experimental findings nor did the predictions of the Mataigne et al. model for multi-element alloys. Investigations of the internal oxide network at the grain boundaries revealed a multilayer oxide structure composed of amorphous SiO2 and crystalline MnSiO3, respectively, at the oxide core and outer shell. A mechanism for the formation of the oxide morphologies observed, based on kinetic and thermodynamic factors, was proposed. It is expected that only the fine and nodule-like MnO oxides formed on the surface of the samples annealed under the 278 K (+ 5 °C) dew-point process atmosphere for 60 and 120 seconds are sufficiently thin and of the desired dispersed morphology to promote reactive wetting by the molten galvanizing bath.

  15. Final report on CCT-K6: Comparison of local realisations of dew-point temperature scales in the range -50 °C to +20 °C

    Science.gov (United States)

    Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.

    2015-01-01

    A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Use of dew-point detection for quantitative measurement of sweating rate

    Science.gov (United States)

    Brengelmann, G. L.; Mckeag, M.; Rowell, L. B.

    1975-01-01

    A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

  17. Vertical profiles of ozone, carbon monoxide, and dew-point temperature obtained during GTE/CITE 1, October-November 1983. [Chemical Instrumentation Test and Evaluation

    Science.gov (United States)

    Fishman, Jack; Gregory, Gerald L.; Sachse, Glen W.; Beck, Sherwin M.; Hill, Gerald F.

    1987-01-01

    A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.

  18. Sales gas hydrocarbon dew point control with a refrigeration plant; Konditionierung des Kohlenwasserstofftaupunktes im Verkaufsgas mittels einer Kaelteanlage

    Energy Technology Data Exchange (ETDEWEB)

    Konieczny, J.; Scsepka, H. [OMV Aktiengesellschaft, Exploration and Production, Gaenserndorf (Austria)

    2004-11-01

    A new refrigeration plant was put on stream in the gas plant Aderklaa, Austria in the fall 2003. The quality criteria inherent to hydrocarbon dew point of the sales gas have already been accomplished. The contract (Allgemeinen Netzzugangsbedingungen) defines the hydrocarbon dew point at the value of 0 C with a pressure ranging 0-70 bar(g). Process facilities are a gas/gas-heat exchanger and a low-temperature-separator flanged to the chiller. A propane cycle produces the required cooling energy. The propane cycle consists of two propane compressors, one of them as back up, a condenser, an accumulator and an evaporator. About 50,000 m{sup 3} (V{sub n}) sales gas per hour are produced at a working pressure of 65 bar(g). Process gas coming from the sweetening plant Aderklaa I is lowered to a temperature of -14 C, where approx. 250 litres liquid hydrocarbons per hour are separated and saved. When the refrigeration plant was designed, attention was given to the operating costs to keep them low. This could be achieved by maximising surface area for heat transfer in the gas/gas-heat exchanger. After commissioning and start-up, full operability of the new plant was tested and documented. The pre-set project goals were accomplished, with respect to both the technical point of view and the economic aspects. (orig.)

  19. Control of dew and frost formation on leaf by radiative cooling

    International Nuclear Information System (INIS)

    Matsui, T.; Eguchi, H.; Mori, K.

    1981-01-01

    A radiative cooling system was developed to control dew and frost formations and to examine the effect of the radiative cooling on the leaf temperature. The growth chamber was provided with a box which was constructed by using heat insulating materials to minimize the disturbances and to regulate the air current. A cooling coil (cooling surface of 300 cm was equipped at the bottom of the box and manipulated by a refrigerator of 1, 430 kcal hour -1 , and a concave mirror was attached to the ceiling of the box to facilitate the reflection of the radiation from the leaf to the cooling coil. The moisture in air was supplied by flowing the controlled air (0.2 m min -1 ) into the box. The distribution of dew point temperatures was almost uniform horizontally even under vertically slight conversion (downward velocity of 1.3 cm sec -1 ) of the air. The leaf temperature became about 1.0°C lower than the ambient air temperature under the radiative cooling. The dew and the frost were clearly observed on the leaf after the time when the leaf temperature had become lower than the dew point temperature. The dew increased in size in course of time, and the frost varied in shape and in size with the temperatures. Thus, artificial formations of the dew and the frost were made possible by the radiative cooling system developed in this experiment

  20. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −25 °C TO +20 °C

    Science.gov (United States)

    Meyer, C.W.; Hill, K.D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952

  1. STUDY ON THE DEW POINT TEMPERATURE IN AREAS WITH SUPERFICIAL LIMESTONE UNDERGROUND ENVIRONMENT (SCREE IN THE GHIMBAV AREA, LEAOTA MOUNTAINS, 2014

    Directory of Open Access Journals (Sweden)

    Magdalin-Leonard Dorobăţ

    2015-07-01

    Full Text Available The dew point of a mixture of a gas (air and the water vapors represents the temperature at which the cold air becomes saturated in water vapors and they condensate. Sometimes, especially in colder periods, it is more revealing regarding the water quantity in the air as vapors, than the relative humidity indicator. The field observations have shown that, always, in the surveys in the ecologic stationaries I have installed in limestone scree in Leaota Massive, condense is formed on the walls of the PVC tubes, irrespective of the season. The continuous measuring, for a period of several months, of more abiotic parameters, amongst which the temperature of the dew point was carried out with dataloggers, which were installed at different depths in limestone scree. This type of continuous monitoring of abiotic parameters at different scree depths is a premiere for Leaota and even is a first for Romania.

  2. Dew measurement and estimation of rain-fed jujube (Zizyphus jujube Mill) in a semi-arid loess hilly region of China

    Institute of Scientific and Technical Information of China (English)

    WANG Xing; GAO Zhiyong; WANG Youke; Wang Zhi; JIN Shanshan

    2017-01-01

    Dew is an important water source for plants in arid and semi-arid regions.However,information on dew is scarce in such regions.In this study,we explored dew formation,amount,and duration of rain-fed jujube (Zi(w)phus jujube Mill) trees in a semi-arid loess hilly region of China (i.e.,Mizhi County).The data included dew intensity and duration,relative humidity,temperature,and wind speed measured from 26 July to 23 October,2012 and from 24 June to 17 October,2013 using a micro-climate system (including dielectric leaf wetness sensors,VP-3 Relative Humidity/Temperature Sensor,High Resolution Rain Gauge,and Davis Cup Anemometer).The results show that atmospheric conditions of relative humidity of >78% and dew point temperature of 1℃C-3℃C are significantly favorable to dew formation.Compared with the rainfall,dew was characterized by high frequency,strong stability,and long duration.Furthermore,heavy dew accounted for a large proportion of the total amount.The empirical models (i.e.,relative humidity model (RH model) and dew point depression model (DPD model)) for daily dew duration estimation performed well at 15-rain intervals,with low errors ranging between 1.29 and 1.60 h,respectively.But it should be noted that the models should be calibrated firstly by determining the optimal thresholds of relatively humidity for RH model and dew point depression for DPD model.For rain-fed jujube trees in the semi-arid loess hilly regions of China,the optimal threshold of relative humidity was 78%,and the optimal upper and lower thresholds of dew point depression were 1℃C and 5℃C,respectively.The study further demonstrates that dew is an important water resource that cannot be ignored for rain-fed jujube trees and may affect water balance at regional scales.

  3. Flue gas heat recovery operating below the dew point and its utilisation for low temperature heating installations

    Energy Technology Data Exchange (ETDEWEB)

    Wilsdorf, J.

    1986-11-01

    This paper deals at first with the characteristics of two principal systems for the flue gas heat recovery by reducing the temperature below the dew point. With test results on experimental plants are shown the typical differences between surface and direct contact heat exchange. A second part informs about experiences from the application for low temperature heating installations, especially about thermodynamics condensate quality and technical design. The possible increasing of the efficiency ranges between 10 to 20 per cent.

  4. Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity Generators

    Science.gov (United States)

    Benyon, R.; Vicente, T.

    2012-09-01

    The comparison of two high-range standard humidity generators used by Instituto Nacional de Técnica Aeroespacial to realize dew-point temperature in the range from -10 °C to +95 °C has been performed using state-of-the art transfer standards and measurement procedures, over their overlapping range from -10 °C to +75 °C. The aim of this study is to investigate the level of agreement between the two generators, to determine any bias, and to quantify the level of consistency of the two realizations. The measurement procedures adopted to minimize the effect of the influence factors due to the transfer standards are described, and the results are discussed in the context of the declared calibration and measurement capabilities (CMCs).

  5. Measurement of evaporative water loss in small animals by dew-point hygrometry.

    Science.gov (United States)

    Bernstein, M H; Hudson, D M; Stearns, J M; Hoyt, R W

    1977-08-01

    This paper presents the procedures and equations to be utilized for measurement of evaporative water loss (mw), by use of the dew-point hygrometer, in small animals exposed to air containing water vapor in an open-flow system. The system accounted accurately for the water evaporated from a bubble flask. In addition, hygrometric measurements of pulmocutaneous mw in pigeons (Columba livia, mean mass 0.31 kg) agreed closely with simultaneous gravimetric measurements, utilizing a desiccant in the sample stream, in a manner independently of air temperature (Ta, 20 or 40 degrees C), ambient water vapor pressure (PW, 4-16 10(2) Pa), or mw (5-66 mg-min-1). Evaporation in pigeons was independent of PW at 20 degrees C, but increased with decreasing PW at 40 degrees C, suggesting differences in ventilatory adjustments to changes in PW at the two temperatures.

  6. Characterisation of a microwave re-entrant cavity resonator for phase-equilibrium measurements and new dew-point data for a (0.25 argon + 0.75 carbon dioxide) mixture

    International Nuclear Information System (INIS)

    Tsankova, Gergana; Richter, Markus; Madigan, Adele; Stanwix, Paul L.; May, Eric F.; Span, Roland

    2016-01-01

    Highlights: • A microwave reentrant cavity resonator was refurbished and extensively characterised. • Vacuum resonance frequencies and Q-factors were modelled and experimentally validated. • Whispering gallery-type modes first-time reported for present cavity geometry. • Dew points of a (0.2491 argon + 0.7509 carbon dioxide) mixture were measured. • Measurements were carried out from T = (252–280) K at pressures up to 6.9 MPa. - Abstract: An apparatus based on a microwave re-entrant cavity resonator, originally built for accurate measurements of the dielectric permittivity of natural gas mixtures, was refurbished and extensively characterised. This was done to enable the future investigation of phase equilibria and (p, ρ, T, x) behaviour of fluid mixtures utilizing the present experimental technique. Vacuum resonance frequencies and Q-factors of the resonator’s modes were modelled using both analytic and finite element methods, and found to compare well with experimental values. The finite element models helped to identify two whispering gallery-type modes not previously reported for such cavity geometries. The models also predict distributions of the electric and magnetic fields in the re-entrant cavity resonator useful for identifying regions in the cavity more sensitive to the presence of a liquid. Following the resonator’s characterisation, its ability to measure dew points was tested using a gravimetrically prepared (0.2501 argon + 0.7499 carbon dioxide) mixture over the temperature range from (252 to 280) K at pressures from (2.8 to 6.9) MPa. The combined expanded uncertainty with a level of confidence of approximately 95% (k = 2) in dew-point temperature and pressure ranged between (0.025 and 0.044) K and from (0.009 to 0.015) MPa, respectively. We compared the experimental dew-point pressures with the recently developed multi-parameter equation of state optimised for combustion gases (EOS-CG), showing relative deviations in the range of (0

  7. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -30 °C TO +20 °C.

    Science.gov (United States)

    Meyer, C W; Solano, A

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.

  8. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −30 °C TO +20 °C

    Science.gov (United States)

    Meyer, C.W.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029

  9. Application of model MTS5 dew-point meter in gas sampling and analyzing system of HTR-10

    International Nuclear Information System (INIS)

    Zhu Jiang; Li Zhihui

    2010-01-01

    The feature of humidity detector to measure the content of water in pure helium of main loop of reactor was discussed, and the circumstances using Al 2 O 3 moisture sensor to measure the content of water in helium on-line were introduced. During those few years, the dew-point meter has sufficed to measure the content of water in the helium gas during the running of the reactor. On the other hand, excursion can happen when the instrument running. Demarcate must be made periodically to improve the veracity of the meter. (authors)

  10. Fort St. Vrain high temperature gas-cooled reactor. Pt. 12. The dew point moisture monitor testing program

    Energy Technology Data Exchange (ETDEWEB)

    Olson, H.G. (Colorado State Univ., Fort Collins (USA). Dept. of Mechanical Engineering); Brey, H.L. (Public Service Co. of Colorado, Denver (USA)); Swart, F.E. (Gas-Cooled Reactor Associates, La Jolla, CA (USA)); Forbis, J.M. (Storage Technology Corp., Louisville, CO (USA))

    1982-09-01

    Moisture ingress into the core volume could cause damaging reactions with the moderator-reflector graphite and burnable poison, therefore a dew point moisture monitoring system has been developed with the basic design criteria that a plant protective system trip is signaled after the system detects high primary coolant helium moisture levels and that the system is able to correctly identify which of two steam generator loops is leaking. Modifications to the sample supplies to the monitors were necessary to reduce the system's unsatisfactory response time at lower reactor power levels.

  11. Environmental dew point and skin and lip weathering.

    Science.gov (United States)

    Devillers, C; Piérard, G E; Quatresooz, P; Piérard, S

    2010-05-01

    Xerosis represents a physiological response of the stratum corneum (SC) to environmental threats. The influence of the environmental dew point (DP) is not fully understood. This parameter is the air temperature at which the relative humidity is maximum. This study aimed to assess the relationship between the environmental DP and the water-holding capacity of the skin and lower lip vermilion. For comparison, SC property was evaluated after occlusive application of cooled and uncooled hydrogel pads. Electrometric measurements using a dermal phase meter (DPM) device were performed on the back of the hands, the cheeks and the lower lip of 40 healthy menopausal women. Assessments were performed in the outdoor conditions during winter and spring. The same measurements were recorded after hydrogel pads, at room temperature or cooled to 4 degrees C, were placed for 15 min on the test sites. The environmental DP was recorded at each evaluation time. The SC water-holding capacity was discretely influenced by the DP. In the open-air environmental conditions, a positive linear relationship was found on the cheeks between the DP and DPM values. The relationship was weaker on the lips. Conversely, a consistent increase in DPM values was recorded immediately after removal of the cooled and uncooled hydrogel pads. The observations made in the open-air testing conditions are consistent with the predicted events following the Arrhenius law. By contrast, the combination of cooling and occlusion by the hydrogel pads is responsible for the reverse effect on the SC.

  12. Determination of equilibrium phase composition in the Hg-HgTe-CdTe system by ''dew point'' method

    International Nuclear Information System (INIS)

    Vanyukov, A.V.; Krotov, I.I.; Ermakov, A.I.

    1978-01-01

    Using the ''dew point'' method a study has been made of the equilibrium composition of the solid and liquid phases in the Hg-HgTe-CdTe system at 404, 435 and 454 deg C. It has been pointed out that crystallization of cadmium-rich solid solutions of Cdsub(x)Hgsub(1-x) Te takes place from a liquid phase with a much higher concentration of Hg. The activity of Hg in the liquid phase increases along the liquidus isotherm in the direction from section Hg-HgTe to section HgCdTe in accordance with the increase of its concentration. An increase in activity of Hg in the solid phase of Cdsub(x)Hgsub(1-x)Te has been noted with the reduction of its concentration

  13. Numerical investigation of the energy performance of a guideless irregular heat and mass exchanger with corrugated heat transfer surface for dew point cooling

    International Nuclear Information System (INIS)

    Xu, Peng; Ma, Xiaoli; Diallo, Thierno M.O.; Zhao, Xudong; Fancey, Kevin; Li, Deying; Chen, Hongbing

    2016-01-01

    The paper presents an investigation into the energy performance of a novel irregular heat and mass exchanger for dew point cooling which, compared to the existing flat-plate heat exchangers, removed the use of the channel supporting guides and implemented the corrugated heat transfer surface, thus expecting to achieve the reduced air flow resistance, increased heat transfer area, and improved energy efficiency (i.e. Coefficient of Performance (COP)) of the air cooling process. CFD simulation was carried out to determine the flow resistance (K) factors of various elements within the dry and wet channels of the exchanger, while the ‘finite-element’ based ‘Newton-iteration’ numerical simulation was undertaken to investigate its cooling capacity, cooling effectiveness and COP at various geometrical and operational conditions. Compared to the existing flat-plate heat and mass exchangers with the same geometrical dimensions and operational conditions, the new irregular exchanger could achieve 32.9%–37% higher cooling capacity, dew-point and wet-bulb effectiveness, 29.7%–33.3% higher COP, and 55.8%–56.2% lower pressure drop. While undertaking dew point air cooling, the irregular heat and mass exchanger had the optimum air velocity of 1 m/s within the flow channels and working-to-intake air ratio of 0.3, which allowed the highest cooling capacity and COP to be achieved. In terms of the exchanger dimensions, the optimum height of the channel was 5 mm while its length was in the range 1–2 m. Overall, the proposed irregular heat and mass exchanger could lead to significant enhanced energy performance compared to the existing flat-plate dew point cooling heat exchanger of the same geometrical dimensions. To achieve the same amount cooling output, the irregular heat and mass exchanger had the reduced size and cost against the flat-plate ones. - Highlights: • Numerical investigation of an irregular heat and mass exchanger was undertaken. • A

  14. The change of steel surface chemistry regarding oxygen partial pressure and dew point

    Science.gov (United States)

    Norden, Martin; Blumenau, Marc; Wuttke, Thiemo; Peters, Klaus-Josef

    2013-04-01

    By investigating the surface state of a Ti-IF, TiNb-IF and a MnCr-DP after several series of intercritical annealing, the impact of the annealing gas composition on the selective oxidation process is discussed. On behalf of the presented results, it can be concluded that not the general oxygen partial pressure in the annealing furnace, which is a result of the equilibrium reaction of water and hydrogen, is the main driving force for the selective oxidation process. It is shown that the amounts of adsorbed gases at the strip surface and the effective oxygen partial pressure resulting from the adsorbed gases, which is mainly dependent on the water content of the annealing furnace, is driving the selective oxidation processes occurring during intercritical annealing. Thus it is concluded, that for industrial applications the dew point must be the key parameter value for process control.

  15. Evaluation of the Long-Term Stability and Temperature Coefficient of Dew-Point Hygrometers

    Science.gov (United States)

    Benyon, R.; Vicente, T.; Hernández, P.; De Rivas, L.; Conde, F.

    2012-09-01

    The continuous quest for improved specifications of optical dew-point hygrometers has raised customer expectations on the performance of these devices. In the absence of a long calibration history, users with a limited prior experience in the measurement of humidity, place reliance on manufacturer specifications to estimate long-term stability. While this might be reasonable in the case of measurement of electrical quantities, in humidity it can lead to optimistic estimations of uncertainty. This article reports a study of the long-term stability of some hygrometers and the analysis of their performance as monitored through regular calibration. The results of the investigations provide some typical, realistic uncertainties associated with the long-term stability of instruments used in calibration and testing laboratories. Together, these uncertainties can help in establishing initial contributions in uncertainty budgets, as well as in setting the minimum calibration requirements, based on the evaluation of dominant influence quantities.

  16. Wireless sensor network-based greenhouse environment monitoring and automatic control system for dew condensation prevention.

    Science.gov (United States)

    Park, Dae-Heon; Park, Jang-Woo

    2011-01-01

    Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop's surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control.

  17. Wireless Sensor Network-Based Greenhouse Environment Monitoring and Automatic Control System for Dew Condensation Prevention

    Science.gov (United States)

    Park, Dae-Heon; Park, Jang-Woo

    2011-01-01

    Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop’s surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control. PMID:22163813

  18. Exploitation of humid air latent heat by means of solar assisted heat pumps operating below the dew point

    International Nuclear Information System (INIS)

    Scarpa, Federico; Tagliafico, Luca A.

    2016-01-01

    Highlights: • The opportunity of humid air latent heat exploitation by DX-SAHP is investigated. • A set of experimental tests confirms this opportunity and quantifies it as relevant. • A parametric analysis is performed, via simulation, to deepen the subject. • The energy gain is relevant during both night and daytime. - Abstract: Nowadays, the exploitation of environmental exergy resources for heating purposes (solar energy, convection heat transfer from ambient air, moist air humidity condensation) by means of properly designed heat pump systems is a possible opportunity. In particular, the use of direct expansion solar assisted heat pumps (DX-SAHP) is investigated in this study, when a bare external plate (the solar collector) is kept at temperatures lower than the dew point temperature of ambient air, so that condensation takes place on it. The potential of this technology is settled and an instrumented prototype of a small DX-SAHP system is used to verify the actual performance of the system, in terms of specific thermal energy delivered to the user, efficiency and regulation capabilities. Results clearly show that the contribution of the condensation is significant (20%–30% of the total harvested energy) overnight or in cloudy days with very low or no solar irradiation, and must be taken into account in a system model devoted to describe the DX-SAHP behavior. During daytime, the percentage gain decreases but is still consistent. By investigating along these lines, the heat due to condensation harvested by the collector is found to be a function of the dew-point temperature alone.

  19. [Comparison of ability to humidification of inspired air through the nose and oral cavity using dew point hygrometer].

    Science.gov (United States)

    Paczesny, Daniel; Rapiejko, Piotr; Weremczuk, Jerzy; Jachowicz, Ryszard; Jurkiewicz, Dariusz

    2007-01-01

    Aim of this study was to check at the hospital the dew point hygrometer for fast measurement of air humidity in upper airways. The nose ability to humidification of inspired air and partially recover moisture from expired air was evaluated. Measurements from respiration through the nose and oral cavity were compared. The study was carried out in a group of 30 people (8 female and 22 male), age group 18 to 70 (mean age: 37 years old). In 22 of the participants there were no deviation from normal state in laryngologic examination, while in 4 participants nasal septum deviation without imaired nasal; oatency was found, in other 3--nasal vonchae hyperthrophy and in 1--nasal polips (grade I). The measurements of air humidity in upper air ways was done using specially designed and constructed measurement system. The air inspired through the nose and oral cavity is humidified. For typical external conditions (T = 22 degrees C i RH = 50%) the nose humidifies inspired air two times better then oral cavity (short time range of measurement approximately 1 min). Moisture from expired air through the nose is partially recovered (for patients with regular patency is 25% of the value of humidifying of inspired air). The oral cavity does not have ability to partially recovery moisture form expired air. The paper presented fast dew point hygrometer based on semiconductor microsystems for measurement humidity in inspired and expired air through the nose and oral cavity. Presented system can be a proper instrument for evaluation of nasal functions.

  20. Effect of the temperature and dew point of the decarburization process on the oxide subscale of a 3% silicon steel

    Energy Technology Data Exchange (ETDEWEB)

    Cesar, Maria das Gracas M.M. E-mail: gracamelo@acesita.com.br; Mantel, Marc J

    2003-01-01

    The oxide subscale formed on the decarburization annealing of 3% Si-Fe was investigated using microscopy and spectroscopy techniques. It was found that the morphology as well as the molecular structure of the subscale are affected by temperature and dew point. The results suggest that there is an optimum level of internal oxidation and an optimum fayalite/silica ratio in the subscale to achieve a oriented grain silicon steel having a continuous and smooth ceramic film and low core loss.

  1. CANDU pressure tube leak detection by annulus gas dew point measurement. A critical review

    International Nuclear Information System (INIS)

    Greening, F.R.

    2017-01-01

    In the event of a pressure tube leak from a small through-wall crack during CANDU reactor operations, there is a regulatory requirement - referred to as Leak Before Break (LBB) - for the licensee to demonstrate that there will be sufficient time for the leak to be detected and the reactor shut down before the crack grows to the critical size for fast-uncontrolled rupture. In all currently operating CANDU reactors, worldwide, this LBB requirement is met via continuous dew point measurements of the CO_2 gas circulating in the reactor's Annulus Gas System (AGS). In this paper the historical development and current status of this leak detection capability is reviewed and the use of moisture injection tests as a verification procedure is critiqued. It is concluded that these tests do not represent AGS conditions that are to be expected in the event of a real pressure tube leak.

  2. CANDU pressure tube leak detection by annulus gas dew point measurement. A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Greening, F.R. [CTS-NA, Tiverton, ON (Canada)

    2017-03-15

    In the event of a pressure tube leak from a small through-wall crack during CANDU reactor operations, there is a regulatory requirement - referred to as Leak Before Break (LBB) - for the licensee to demonstrate that there will be sufficient time for the leak to be detected and the reactor shut down before the crack grows to the critical size for fast-uncontrolled rupture. In all currently operating CANDU reactors, worldwide, this LBB requirement is met via continuous dew point measurements of the CO{sub 2} gas circulating in the reactor's Annulus Gas System (AGS). In this paper the historical development and current status of this leak detection capability is reviewed and the use of moisture injection tests as a verification procedure is critiqued. It is concluded that these tests do not represent AGS conditions that are to be expected in the event of a real pressure tube leak.

  3. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    Science.gov (United States)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Bilateral key comparison SIM.T-K6.2 on humidity standards in the dew/frost-point temperature range from -20 °c to 20 °c

    Science.gov (United States)

    Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.

    2014-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Development of manufacturing of low dew-point mixed gas of butane-air

    Energy Technology Data Exchange (ETDEWEB)

    Komine, Hitoshi

    1988-09-10

    A dehumidifying plant was installed to supply high-quality dehumidified butane-air mixed gas aiming at saving the heat required for vaporizing liquid butane by the heat exchange with the potential heat of air as well as the dehumidification of the air used for the mixed gas by cooling with the vaporizing latent heat of liquid butane. The plant has been smoothly operated since August, 1987. Butane sent from the air-dehumidifier is completely vaporized by hot water in the vaporizer and the vaporized butane ejected by the Venturi mixer to mix with the dehumidified air. The gas production capacity is 3000Nm/sup 3//h and the treating capacities of butane and air are 661 and 2339 Nm/sup 3//h, respectively. The dew point of the mixed gas is 18/sup 0/C under 0.7kg/cm/sup 2/G at atmospheric temperature of 38/sup 0/C subject to the operation of the plant only in hot and humid summer. It was demonstrated that the plant is characterized by low construction and operating costs, low level of noise and stable heat value of the product gas. (5 figs, 4 tabs, 1 photo)

  6. Catalysts macroporosity and their efficiency in sulphur sub-dew point Claus tail gas treating processes

    Energy Technology Data Exchange (ETDEWEB)

    Tsybulevski, A.M.; Pearson, M. [Alcoa Industrial Chemicals, 16010 Barker`s Point Lane, Houston, TX (United States); Morgun, L.V.; Filatova, O.E. [All-Russian Research Institute of Natural Gases and Gas Technologies VNIIGAZ, Moscow (Russian Federation); Sharp, M. [Porocel Corporation, Westheimer, Houston, TX (United States)

    1996-10-08

    The efficiency of 4 samples of alumina catalyst has been studied experimentally in the course of the Claus `tail gas` treating processes at the sulphur sub-dew point (TGTP). The samples were characterized by the same chemical and crystallographic composition, the same volume of micropores, the same surface area and the same catalytic activity but differed appreciably in the volume of macropores. An increase in the effective operation time of the catalysts before breakthrough of unrecoverable sulphur containing compounds, with the increasing macropore volume has been established. A theoretical model of the TGTP has been considered and it has been shown that the increase in the sulphur capacity of the catalysts with a larger volume of macropores is due to an increase in the catalysts efficiency factor and a slower decrease in their diffusive permeability during filling of micropores by sulphur

  7. The Effect of Climate Change on Variations in Dew Amount in a Paddy Ecosystem of the Sanjiang Plain, China

    Directory of Open Access Journals (Sweden)

    Yingying Xu

    2015-01-01

    Full Text Available Due to global warming, a drying and warming trend has been observed over the last 50 years in the Sanjiang Plain of Heilongjiang Province, China, which could significantly affect the condensation of vapor in paddy ecosystems. Dew is a crucial factor in the water and nutrient cycling of farmland ecosystems, and it exerts an important influence on fertilization and other agricultural activities. In order to reveal the effects of global warming on dew variation in a paddy ecosystem, an in situ experiment was conducted in paddy fields in the Sanjiang Plain during the growing seasons of 2011 to 2013. Dew was collected and measured with a poplar stick. The results of correlation analysis between meteorological factors and dew intensity in the paddy ecosystem indicate that the dew point temperature and relative humidity significantly influenced the dew intensity. Based on synchronous meteorological data, a stepwise linear multivariation regression model was established to predict dew amount. The model successfully interpreted the relationship between simulated and measured dew intensity. The results suggest that a warmer and drier climate would lead to a reduction in dew amount because water cannot condense when relative humidity falls below 71%.

  8. Application of passive radiative cooling for dew condensation

    International Nuclear Information System (INIS)

    Beysens, Daniel; Muselli, Marc; Milimouk, Iryna

    2006-01-01

    Dew water was collected from several passive foil-based radiative condensers established in a variety of geographic settings: continental (Grenoble, in an alpine valley, and Brive-la-Gaillarde, in the Central Massif volcanic area, both in France), French Atlantic coast (Bordeaux), eastern Mediterranean (Jerusalem, Israel), and the island of Corsica (Ajaccio, France) in the Mediterranean Sea. In Ajaccio two large 30 m 2 condensers have been operating since 2000. Additional semi-quantitative dew measurements were also carried out for Komiza, island of Vis (Croatia) in the Adriatic Sea, and in Mediterranean Zadar and Dubrovnik (both in Croatia). Dew potential was calculated for the Pacific Ocean island of Tahiti (French Polynesia). The data show that significant amounts of dew water can be collected. Selected chemical and biological analyses established that dew is, in general, potable. Continued research is required for new and inexpensive materials that can enhance dew condensation

  9. Fog and dew climatology over Hisar, India

    International Nuclear Information System (INIS)

    Surender, S.; Diwan, S.; Rao, V.U.M.

    2006-05-01

    In many arid and semi-arid areas, pumped ground water and the water from streams, rivers and reservoirs is no longer sufficient to cover the ever increasing water demand. Therefore new interest in 'marginal' water resources like fog and dew harvesting are to be developed after studying climatology of these parameters in a region. The observations on dew and fog events recorded at Hisar, representing semi-arid region of India during winter season (October to March) for the period 1980 to 2005 have been analyzed. The total annual dew amount in winter season ranged between 33 mm (1987-88) and 79 mm (1981-82) during the period under study. The seasonal dewfall showed a decreasing trend of 1.4 mm during the period under investigation. Average maximum dew events (26.1) were recorded during November and average minimum dew events were recorded in February. In a particular season, the highest dew events (168) were observed during the winter seasons of 1982-83 and 1983-84, whereas, the minimum number of dew events (97) was reported during 1998-99. Interestingly, an increasing trend (1.3 day/season) in occurrence of fog events was seen. Average maximum foggy events (8.7) recorded in a month were observed in January. In a particular season, the maximum foggy events (41) were recorded during 2002-03 and the minimum (2) during 1983-84. To achieve the objective of alternate source of water and to assess the impact of dew and fog on agricultural crops for their growth and development, inputs from various specialized disciplines and allied sciences engaged in meteorological applications along with forecasting skills from non scientific quarters are needed to predict the weather parameter accurately, thus the active cooperation between meteorological/remote sensing agencies, agricultural organizations and farming community is needed for sustainable agricultural development in scarce/limited water availability regions. (author)

  10. Development of producing equipment of mixed butane-air with low dew point. Energy saving dewatering apparatus and 6A-Gas producing apparatus utilizing vaporization latent heat of butane and potential heat of air

    Energy Technology Data Exchange (ETDEWEB)

    Komine, Jin; Okada, Hiroto; Taniue, Nobuo; Tanoue, Keiju; Yamada, Tatsuhiko; Maekawa, Hisami; Murakami, Keiji

    1988-02-10

    A producing equipment of mixed butane-air with low dew point was developed. The dewatering was made during the period from the middle of May to the middle of October with high atmospheric humidity. The production capacity of the mixed gas is 3000 Nm/sup 3/ of 22% of butane and 78% of air per hour. The designed dew point is 18/sup 0/C or less under the pressure of 0.7 kg/cm/sup 2/G. The saturation temperature is 7.5/sup 0/C after the liquid butane is evacuated by a regulating valve. The air introduced into the dehumidifier through finned tubes is cooled to dewater based on those data. The partially vaporized butane is completely gasified by hot water in a vaporizer and mixed with the dewatered air by a venture mixer to produce the mixed butane-air. When the dewatering is incomplete, the spray nozzle must be just exchanged. The dew point of the produced gas was sufficiently below the designed value. The investment cost is low. The total operating cost is reduced by the remarkably decreased fuel cost though the power cost is increased. The noise level is low and the heat control is easy. (11 figs, 4 tabs, 1 photo)

  11. Bilateral key comparison SIM.T-K6.1 on humidity standards in the dew/frost-point temperature range from -25 °C to +20 °C

    Science.gov (United States)

    Meyer, C. W.; Hill, K. D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Final report: Bilateral key comparison SIM.T-K6.3 on humidity standards in the dew/frost-point temperature range from -30°C to 20°C

    Science.gov (United States)

    Huang, Peter; Meyer, Christopher; Brionizio, Julio D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. The Mollier diagram in theory and practice. Part 3. Examples on Calculation of Dew Point Cooling; Het Mollierdiagram in theorie en praktijk. Deel 3. Rekenvoorbeelden Dauwpuntkoeling

    Energy Technology Data Exchange (ETDEWEB)

    Kouwenhoven, H.J.L. [Frigidarium, Driebergen-Rijsenburg (Netherlands); Huizinga, H.T. [Heat Transfer Holland HTH, Zuidwolde (Netherlands); Bootsveld, N.R. [YNO, Delft (Netherlands); Janssen, M. [Re-gent, Helmond (Netherlands); Uges, P.G.H. [StatiqCooling, Deventer (Netherlands)

    2007-04-15

    The use of direct and indirect adiabatic cooling, and recently in particular indirect diabatic cooling (dew point cooling) require knowledge of the Mollier diagram. [Dutch] Het gebruik van direct en indirect werkende adiabatische koeling en recentlijk vooral de indirect werkende systemen zoals diabatische koeling (dauwpuntkoeling, al of niet uitgevoerd als statische koeling) vragen om kennis van het Mollierdiagram.

  14. Projected climate change impacts upon dew yield in the Mediterranean basin

    Energy Technology Data Exchange (ETDEWEB)

    Tomaszkiewicz, M. [Department of Civil & Environmental Engineering, Faculty of Engineering & Architecture, American University of Beirut, Beirut (Lebanon); Abou Najm, M., E-mail: majdian@aub.edu.lb [Department of Civil & Environmental Engineering, Faculty of Engineering & Architecture, American University of Beirut, Beirut (Lebanon); Beysens, D. [Physique et Mecanique des Milieux Heterogenes, UMR 7636 CNRS — ESPCI, Universite Pierre et Marie Curie — Universite Paris Diderot, 10 rue Vauquelin, 75005 Paris (France); Service des Basses Temperatures, CEA-Grenoble & Universite Joseph Fourier, Grenoble (France); OPUR, 60 rue Emeriau, 75015 Paris (France); Alameddine, I. [Department of Civil & Environmental Engineering, Faculty of Engineering & Architecture, American University of Beirut, Beirut (Lebanon); Bou Zeid, E. [Department of Civil and Environmental Engineering, Princeton University, Princeton, NJ 08540 (United States); El-Fadel, M. [Department of Civil & Environmental Engineering, Faculty of Engineering & Architecture, American University of Beirut, Beirut (Lebanon)

    2016-10-01

    Water scarcity is increasingly raising the need for non-conventional water resources, particularly in arid and semi-arid regions. In this context, atmospheric moisture can potentially be harvested in the form of dew, which is commonly disregarded from the water budget, although its impact may be significant when compared to rainfall during the dry season. In this study, a dew atlas for the Mediterranean region is presented illustrating dew yields using the yield data collected for the 2013 dry season. The results indicate that cumulative monthly dew yield in the region can exceed 2.8 mm at the end of the dry season and 1.5 mm during the driest months, compared to < 1 mm of rainfall during the same period in some areas. Dew yields were compared with potential evapotranspiration (PET) and actual evapotranspiration (ET) during summer months thus highlighting the role of dew to many native plants in the region. Furthermore, forecasted trends in temperature and relative humidity were used to estimate dew yields under future climatic scenarios. The results showed a 27% decline in dew yield during the critical summer months at the end of the century (2080). - Highlights: • Dew atlas for Mediterranean region is presented. • Cumulative dew yields can exceed 2.8 mm at the end of the dry season. • Dew yields compared with PET and ET show the role of dew to many native plants. • Forecasted trends under future climatic scenarios show a 27% decline in dew yield.

  15. Critical point analysis of phase envelope diagram

    International Nuclear Information System (INIS)

    Soetikno, Darmadi; Siagian, Ucok W. R.; Kusdiantara, Rudy; Puspita, Dila; Sidarto, Kuntjoro A.; Soewono, Edy; Gunawan, Agus Y.

    2014-01-01

    Phase diagram or phase envelope is a relation between temperature and pressure that shows the condition of equilibria between the different phases of chemical compounds, mixture of compounds, and solutions. Phase diagram is an important issue in chemical thermodynamics and hydrocarbon reservoir. It is very useful for process simulation, hydrocarbon reactor design, and petroleum engineering studies. It is constructed from the bubble line, dew line, and critical point. Bubble line and dew line are composed of bubble points and dew points, respectively. Bubble point is the first point at which the gas is formed when a liquid is heated. Meanwhile, dew point is the first point where the liquid is formed when the gas is cooled. Critical point is the point where all of the properties of gases and liquids are equal, such as temperature, pressure, amount of substance, and others. Critical point is very useful in fuel processing and dissolution of certain chemicals. Here in this paper, we will show the critical point analytically. Then, it will be compared with numerical calculations of Peng-Robinson equation by using Newton-Raphson method. As case studies, several hydrocarbon mixtures are simulated using by Matlab

  16. Critical point analysis of phase envelope diagram

    Energy Technology Data Exchange (ETDEWEB)

    Soetikno, Darmadi; Siagian, Ucok W. R. [Department of Petroleum Engineering, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia); Kusdiantara, Rudy, E-mail: rkusdiantara@s.itb.ac.id; Puspita, Dila, E-mail: rkusdiantara@s.itb.ac.id; Sidarto, Kuntjoro A., E-mail: rkusdiantara@s.itb.ac.id; Soewono, Edy; Gunawan, Agus Y. [Department of Mathematics, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia)

    2014-03-24

    Phase diagram or phase envelope is a relation between temperature and pressure that shows the condition of equilibria between the different phases of chemical compounds, mixture of compounds, and solutions. Phase diagram is an important issue in chemical thermodynamics and hydrocarbon reservoir. It is very useful for process simulation, hydrocarbon reactor design, and petroleum engineering studies. It is constructed from the bubble line, dew line, and critical point. Bubble line and dew line are composed of bubble points and dew points, respectively. Bubble point is the first point at which the gas is formed when a liquid is heated. Meanwhile, dew point is the first point where the liquid is formed when the gas is cooled. Critical point is the point where all of the properties of gases and liquids are equal, such as temperature, pressure, amount of substance, and others. Critical point is very useful in fuel processing and dissolution of certain chemicals. Here in this paper, we will show the critical point analytically. Then, it will be compared with numerical calculations of Peng-Robinson equation by using Newton-Raphson method. As case studies, several hydrocarbon mixtures are simulated using by Matlab.

  17. Dew point temperature affects ascospore release of allergenic genus Leptosphaeria

    Science.gov (United States)

    Sadyś, Magdalena; Kaczmarek, Joanna; Grinn-Gofron, Agnieszka; Rodinkova, Victoria; Prikhodko, Alex; Bilous, Elena; Strzelczak, Agnieszka; Herbert, Robert J.; Jedryczka, Malgorzata

    2018-01-01

    The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs) and multivariate regression trees (MRTs), we selected the best model for each site, as well as for joint two-site combinations. The performance of all computed models was tested against records from 1 year which had not been used for model construction. The statistical analysis of the fungal spore data was supported by a comprehensive study of both climate and land cover within a 30-km radius from the air sampler location. High-performance forecasting models were obtained for individual sites, showing that the local micro-climate plays a decisive role in biology of the fungi. Based on the previous epidemiological studies, we hypothesized that dew point temperature (DPT) would be a critical factor in the models. The impact of DPT was confirmed only by one of the final best neural models, but the MRT analyses, similarly to the Spearman's rank test, indicated the importance of DPT in all but one of the studied cases and in half of them ranked it as a fundamental factor. This work applies artificial neural modeling to predict the Leptosphaeria airborne spore concentration in urban areas for the first time.

  18. Dew point temperature affects ascospore release of allergenic genus Leptosphaeria

    Science.gov (United States)

    Sadyś, Magdalena; Kaczmarek, Joanna; Grinn-Gofron, Agnieszka; Rodinkova, Victoria; Prikhodko, Alex; Bilous, Elena; Strzelczak, Agnieszka; Herbert, Robert J.; Jedryczka, Malgorzata

    2018-06-01

    The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs) and multivariate regression trees (MRTs), we selected the best model for each site, as well as for joint two-site combinations. The performance of all computed models was tested against records from 1 year which had not been used for model construction. The statistical analysis of the fungal spore data was supported by a comprehensive study of both climate and land cover within a 30-km radius from the air sampler location. High-performance forecasting models were obtained for individual sites, showing that the local micro-climate plays a decisive role in biology of the fungi. Based on the previous epidemiological studies, we hypothesized that dew point temperature (DPT) would be a critical factor in the models. The impact of DPT was confirmed only by one of the final best neural models, but the MRT analyses, similarly to the Spearman's rank test, indicated the importance of DPT in all but one of the studied cases and in half of them ranked it as a fundamental factor. This work applies artificial neural modeling to predict the Leptosphaeria airborne spore concentration in urban areas for the first time.

  19. Trends in extremes of temperature, dew point, and precipitation from long instrumental series from central Europe

    Science.gov (United States)

    Kürbis, K.; Mudelsee, M.; Tetzlaff, G.; Brázdil, R.

    2009-09-01

    For the analysis of trends in weather extremes, we introduce a diagnostic index variable, the exceedance product, which combines intensity and frequency of extremes. We separate trends in higher moments from trends in mean or standard deviation and use bootstrap resampling to evaluate statistical significances. The application of the concept of the exceedance product to daily meteorological time series from Potsdam (1893 to 2005) and Prague-Klementinum (1775 to 2004) reveals that extremely cold winters occurred only until the mid-20th century, whereas warm winters show upward trends. These changes were significant in higher moments of the temperature distribution. In contrast, trends in summer temperature extremes (e.g., the 2003 European heatwave) can be explained by linear changes in mean or standard deviation. While precipitation at Potsdam does not show pronounced trends, dew point does exhibit a change from maximum extremes during the 1960s to minimum extremes during the 1970s.

  20. sarcome d'ewing

    African Journals Online (AJOL)

    7 mai 2012 ... Le sarcome d'Ewing est une tumeur osseuse rare corres- pondant à la ... Introduction : petrous Ewing sarcoma is exceptional. We report a ..... (15) Iriz A, Albayrak L, Eryilmaz A. Extraskeletal primary Ewing's sarcoma of the.

  1. TFOS DEWS II Report Executive Summary.

    Science.gov (United States)

    Craig, Jennifer P; Nelson, J Daniel; Azar, Dimitri T; Belmonte, Carlos; Bron, Anthony J; Chauhan, Sunil K; de Paiva, Cintia S; Gomes, José A P; Hammitt, Katherine M; Jones, Lyndon; Nichols, Jason J; Nichols, Kelly K; Novack, Gary D; Stapleton, Fiona J; Willcox, Mark D P; Wolffsohn, James S; Sullivan, David A

    2017-10-01

    This article presents an Executive Summary of the conclusions and recommendations of the 10-chapter TFOS DEWS II report. The entire TFOS DEWS II report was published in the July 2017 issue of The Ocular Surface. A downloadable version of the document and additional material, including videos of diagnostic and management techniques, are available on the TFOS website: www.TearFilm.org. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Filter for underground mining for suction of preferably full cut and part cut machines, to be provided with preheated air, to avoid dropping below the dew point

    Energy Technology Data Exchange (ETDEWEB)

    Hoelter, H.

    1976-10-28

    Particularly when cutting hard rock, the cutting room to be provided with suction is wetted with water from nozzles, which, when sucking out air containing dust with high humidity leads to encrustation in the filter cloth. In order to avoid this, it is proposed that the air should be heated, using heat from the motor driving the ventilator, so that one avoids dropping below the dew point in the filter.

  3. Parametric analysis of a combined dew point evaporative-vapour compression based air conditioning system

    Directory of Open Access Journals (Sweden)

    Shailendra Singh Chauhan

    2016-09-01

    Full Text Available A dew point evaporative-vapour compression based combined air conditioning system for providing good human comfort conditions at a low cost has been proposed in this paper. The proposed system has been parametrically analysed for a wide range of ambient temperatures and specific humidity under some reasonable assumptions. The proposed system has also been compared from the conventional vapour compression air conditioner on the basis of cooling load on the cooling coil working on 100% fresh air assumption. The saving of cooling load on the coil was found to be maximum with a value of 60.93% at 46 °C and 6 g/kg specific humidity, while it was negative for very high humidity of ambient air, which indicates that proposed system is applicable for dry and moderate humid conditions but not for very humid conditions. The system is working well with an average net monthly power saving of 192.31 kW h for hot and dry conditions and 124.38 kW h for hot and moderate humid conditions. Therefore it could be a better alternative for dry and moderate humid climate with a payback period of 7.2 years.

  4. Dew Measurements along a Longitudinal Sand Dune Transect

    NARCIS (Netherlands)

    Jacobs, A.F.G.; Heusinkveld, B.G.; Berkowicz, S.

    2000-01-01

    In a desert environment dew can serve as an important source of moisture for plants, biological crusts, insects and small animals. A measurement programme was carried out within a sand dune belt situated in the northwestern Negev desert, Israel, to measure daily amounts of dew deposition as well as

  5. Wet-bulb, dew point, and air temperature trends in Spain

    Science.gov (United States)

    Moratiel, R.; Soriano, B.; Centeno, A.; Spano, D.; Snyder, R. L.

    2017-10-01

    This study analyses trends of mean ( T m), maximum ( T x), minimum ( T n), dew point ( T d), and wet-bulb temperatures ( T w) on an annual, seasonal, and monthly time scale over Spain during the period 1981-2010. The main purpose was to determine how temperature and humidity changes are impacting on T w, which is probably a better measure of climate change than temperature alone. In this study, 43 weather stations were used to detect data trends using the nonparametric Mann-Kendall test and the Sen method to estimate the slope of trends. Significant linear trends observed for T m, T x, and T n versus year were 56, 58, and 47 % of the weather stations, respectively, with temperature ranges between 0.2 and 0.4 °C per decade. The months with bigger trends were April, May, June, and July with the highest trend for T x. The spatial behaviour of T d and T w was variable, with various locations showing trends from -0.6 to +0.3 °C per decade for T d and from -0.4 to +0.5 °C per decade for T w. Both T d and T w showed negative trends for July, August, September, November, and December. Comparing the trends versus time of each variable versus each of the other variables exhibited poor relationships, which means you cannot predict the trend of one variable from the trend of another variable. The trend of T x was not related to the trend of T n. The trends of T x, T m, and T n versus time were unrelated to the trends versus time of either T d or T w. The trend of T w showed a high coefficient of determination with the trend of T d with an annual value of R 2 = 0.86. Therefore, the T w trend is more related to changes in humidity than temperature.

  6. Spatial interpolation of hourly precipitation and dew point temperature for the identification of precipitation phase and hydrologic response in a mountainous catchment

    Science.gov (United States)

    Garen, D. C.; Kahl, A.; Marks, D. G.; Winstral, A. H.

    2012-12-01

    In mountainous catchments, it is well known that meteorological inputs, such as precipitation, air temperature, humidity, etc. vary greatly with elevation, spatial location, and time. Understanding and monitoring catchment inputs is necessary in characterizing and predicting hydrologic response to these inputs. This is true all of the time, but it is the most dramatically critical during large storms, when the input to the stream system due to rain and snowmelt creates the potential for flooding. Besides such crisis events, however, proper estimation of catchment inputs and their spatial distribution is also needed in more prosaic but no less important water and related resource management activities. The first objective of this study is to apply a geostatistical spatial interpolation technique (elevationally detrended kriging) to precipitation and dew point temperature on an hourly basis and explore its characteristics, accuracy, and other issues. The second objective is to use these spatial fields to determine precipitation phase (rain or snow) during a large, dynamic winter storm. The catchment studied is the data-rich Reynolds Creek Experimental Watershed near Boise, Idaho. As part of this analysis, precipitation-elevation lapse rates are examined for spatial and temporal consistency. A clear dependence of lapse rate on precipitation amount exists. Certain stations, however, are outliers from these relationships, showing that significant local effects can be present and raising the question of whether such stations should be used for spatial interpolation. Experiments with selecting subsets of stations demonstrate the importance of elevation range and spatial placement on the interpolated fields. Hourly spatial fields of precipitation and dew point temperature are used to distinguish precipitation phase during a large rain-on-snow storm in December 2005. This application demonstrates the feasibility of producing hourly spatial fields and the importance of doing

  7. Dew and hoarfrost frequency, formation efficiency and chemistry in Wroclaw, Poland

    Science.gov (United States)

    Gałek, G.; Sobik, M.; Błaś, M.; Polkowska, Ż.; Cichała-Kamrowska, K.; Wałaszek, K.

    2015-01-01

    This article presents the results of a research study concerning a comparison of frequency, formation efficiency and basic physico-chemical properties of dew and hoarfrost in urban conditions. Longer than two-year series of measurements was carried out from 1 February 2008 to 10 March 2010 in Wroclaw, Poland. Sampling of atmospheric deposits was made by means of insulated plain passive radiative condensers, which allowed to collect 222 dew and 96 hoarfrost samples. The results indicate that the frequency of dew days was about threefold greater than hoarfrost days. The formation efficiency of both types of deposits was almost the same, and reached a mean value of about 100 mL·m- 2 per day. The conducted analysis of several meteorological parameters showed that dew and hoarfrost, despite seasonal weather changes, were formed in very similar meteorological conditions. Only water vapor pressure values were in average twice higher in the case of dew and the impact of this parameter on dew and hoarfrost formation efficiency seems to be more complex than expected. The role of night duration in counterbalancing of smaller amount of available moisture in hoarfrost days is not clear. The investigation showed also, that there was an expected clear positive dependence of dew and hoarfrost formation efficiency on relative humidity, and not so evident in the case of temperature inversion, and wind velocity. The physico-chemical analysis indicated that the pH of dew was only slightly lower than the hoarfrost ones, regardless of the deposit formation intensity. Simultaneously, the lower pH values were much more frequent in the case of dew, which resulted from more effective absorption of anthropogenic NO3- and SO42 - ions. For both types of deposits, the average pH was low (4.5-4.8) in relation to majority of studies reported in literature. In spite of seasonal changes of pollutant concentration, various weather conditions and different mechanisms of pollutant absorption of dew

  8. Dew point effect of cooled hydrogel pads on human stratum corneum biosurface.

    Science.gov (United States)

    Xhauflaire-Uhoda, Emmanuelle; Paquet, Philippe; Piérard, Gérald E

    2008-01-01

    Cooled hydrogel pads are used to prevent overheating effects of laser therapy. They do not induce cold injuries to the skin, but their more subtle physiological effects have not been thoroughly studied. To describe the changes in transepidermal water loss and electrometric properties of the skin surface following application of cooled hydrogel pads. Measurements were performed on normal forearm skin of 27 healthy volunteers and on freshly excised skin from abdominoplasty. LaserAid hydrogel pads cooled to 4 degrees C were placed for 15 min on the forearm skin. Measurements of transepidermal water loss (TEWL) and electrometric properties (Corneometer, Nova DPM 900) were performed before application and after removal of the cooled pads. A consistent increase in corneometer units, dermal phase meter (DPM) values and TEWL were recorded at removal of the cooled hydrogel pads. Both the in vivo and in vitro assessments brought similar information. The similar changes disclosed in vitro and in vivo suggest that a common physical process is operating in these conditions. The observed phenomenon is opposite to the predicted events given by the Arrhenius law probably because of the combination of cooling and occlusion by the pads. A dew point effect (air temperature at which relative humidity is maximal) is likely involved in the moisture content of the stratum corneum. Thus, the biological impact of using cooling hydrogel pads during laser therapy is different from the effect of a cryogenic spray cooling procedure. The better preservation of the water balance in the stratum corneum by the cooled hydrogel pads could have a beneficial esthetic effect on laser treated areas. (c) 2008 S. Karger AG, Basel.

  9. On dew and micrometeorology in an arid coastal ecosystem

    NARCIS (Netherlands)

    Heusinkveld, B.G.

    2008-01-01

    This study investigated intriguing aspects of dew within a sandy arid ecosystem situated in the NW Negev desert, Israel. The goal was to quantify dew formation and evaporation processes through sensor design, field measurements and modelling. To do this, two new sensors were developed. The first

  10. The Mollier diagram in theory and practice. Part 2. Evaporative indirect static dew point cooling and the Mollier diagram; Het Mollierdiagram in theorie en praktijk. Deel 2. Verdampingskoeling verklaard vanuit het Mollierdiagram

    Energy Technology Data Exchange (ETDEWEB)

    Uges, P.G.H. (ed.) [StatiqCooling, Deventer (Netherlands)

    2007-02-15

    The use of direct and indirect adiabatic cooling, and recently in particular indirect diabatic cooling (dew point cooling) require knowledge of the Mollier diagram. [Dutch] Het gebruik van direct en indirect werkende adiabatische koeling en recentlijk vooral de indirect werkende systemen zoals diabatische koeling (dauwpuntkoeling, al of niet uitgevoerd als statische koeling) vragen om kennis van het Mollierdiagram.

  11. Dew variability in three habitats of a sand dune transect in a desert oasis ecotone, Northwestern China

    CERN Document Server

    Zhuang, Yanli

    2014-01-01

    Dew, as a supplementary water source, may have an important ecological role in arid and semi-arid regions. During August and September of 2007 and 2008, measurements were taken to investigate the dew accumulation and evaporation patterns in the very early morning hours, in three different habitats (dunetop, footslope, and interdune lowland) of a fixed sand dune in Northwest China. Dew quantities were measured using the cloth-plate method. The results indicated that there was a positive correlation between dew amounts and relative humidity, but a negative correlation between dew amounts and mean temperature. Clear mornings were characterized by higher dew amounts and longer dew duration, whereas less dew was recorded during cloudy and especially windy mornings. Dew continued to condense even after sunrise, although a shorter warming time after dawn is also of vital importance in dew formation. The higher average maximum dew quantities (0.06mm) and longer average dew duration (2.3h) occurred in the interdune lo...

  12. Growth responses of male broilers subjected to increasing air velocities at high ambient temperatures and a high dew point.

    Science.gov (United States)

    Dozier, W A; Lott, B D; Branton, S L

    2005-06-01

    This study examined live performance responses of male broilers to increasing air velocity of 120 and 180 m/min reared under high cyclic temperatures (25-35-25 degrees C) with a 23 degrees C dew point from 21 to 49 d. Birds were reared in an environmental facility containing 2 wind tunnels (4 pens/tunnel) and 6 floor pens (control). At 21 d, 53 birds were placed in each pen of the wind tunnels and control group, respectively, and growth performance was determined weekly. Increasing air velocity from 120 to 180 m/min improved BW and BW gain from 29 to 35, 36 to 42, and 43 to 49 d of age leading to a cumulative advantage of 287 g in BW gain and a 10-point difference in feed conversion from 21 to 49 d of age. Subjecting birds to air velocity improved growth rate, feed consumption, and feed conversion at each weekly interval from 28 to 49 d over the control birds. These results indicate that male broilers approximating 2.0 to 3.0 kg respond to an air velocity of 180 m/min when exposed to high cyclic temperatures.

  13. Mechanisms of corrosion, falling short of dew point and formation of corrosion in boilers and exhaust systems. Mechanismen der Korrosionsbildung, der Taupunktunterschreitung und Entstehung von Korrosionen in Kessel- und Abgassystemen

    Energy Technology Data Exchange (ETDEWEB)

    Marx, E.

    1994-09-01

    In order to save energy boilers for heating systems are run on increasingly lower exhaust gas- and boiler temperatures. Combustion as such depends of type of fuel, boiler and burner design, design of exhaust systems and atmospheric disturbance variables. This article looks at the influence which these factors have on corrosion. Falling short of the dew point is an important parameter in this context. Possibilities of avoiding corrosion are explained. (BWI)

  14. A technical basis to relax the dew point specification for the environment in the vapor space in DWPF canisters

    International Nuclear Information System (INIS)

    Louthan, M.R. Jr.

    1995-05-01

    This memorandum establishes the technical basis to conclude that relaxing, from 0 C to 20 C, the dew point specification for the atmosphere in the vapor space (free volume) of a DWPF canister will not provide an environment that will cause significant amounts of corrosion induced degradation of the canister wall. The conclusion is based on engineering analysis, experience and review of the corrosion literature. The basic assumptions underlying the conclusion are: (1) the canister was fabricated from Type 304L stainless steel; (2) the corrosion behavior of the canister material, including base metal, fusion zones and heat effected zones, is typified by literature data for, and industrial experience with, 300 series austenitic stainless steels; and (3) the glass-metal crevices created during the pouring operation will not alter the basic corrosion resistance of the steel although such crevices might serve as sites for the initiation of minor amounts of corrosion on the canister wall

  15. Dew as an Adaptation Measure to Meet Agricultural and Reforestation Water Demand in a Changing Climate

    Science.gov (United States)

    Tomaszkiewicz, Marlene; Abou Najm, Majdi; Alameddine, Ibrahim; El Fadel, Mutasem

    2014-05-01

    Dew harvesting, believed to be an ancient technique, has recently re-emerged as a viable and sustainable water resource. Nightly yields are relatively low, yet non-negligible, and dew events occur more frequently than rainfall promoting its effectiveness, particularly in arid and semi-arid regions. In this study, we demonstrate how dew can be harvested and subsequently used for small-scale irrigation to meet agricultural and reforestation water demand. Polyethylene dew harvesting systems were constructed and placed in the field. Dew was harvested as a result of the radiative cooling during the night, thus allowing dew formation under conditions of high humidity. Condensed dew formed upon the planar surface was collected by gravity. Water demand for selected crops and trees within a pilot study area (Lebanon) was estimated using a deficit irrigation model. Simulations of water demand requirements of various plants and surfaces were performed and compared to dew volumes to assess the ability of the system to meet all or in part the plant water demands across seasons. Data from the polyethylene low-cost dew condensers have shown that within the pilot study, average nightly dew yields were 0.1 L m-2 of condensing surface with a maximum yield of 0.4 L m-2. Dew events occurred generally more frequently than precipitation events, with an estimated 40% of nights producing dew condensate. This translates to 50 mm of equivalent rainfall on average (during dew nights), with a maximum of 200 mm in one night, if one assumes using drip irrigation over a seedling within a 20 cm2 area. Using a simple deficit irrigation model, it was demonstrated that crops such as the tomato plant, which typically has a growing season during the dry summer, can potentially be irrigated solely by dew, thus eliminating the need for traditional irrigation sources. Similarly, young tree seedlings, such as the cedar tree, can depend upon dew as a primary water resource. Moreover, based on similar

  16. Improving indoor air quality through the use of continual multipoint monitoring of carbon dioxide and dew point.

    Science.gov (United States)

    Bearg, D W

    1998-09-01

    This article summarizes an approach for improving the indoor air quality (IAQ) in a building by providing feedback on the performance of the ventilation system. The delivery of adequate quantities of ventilation to all building occupants is necessary for the achievement of good IAQ. Feedback on the performance includes information on the adequacy of ventilation provided, the effectiveness of the distribution of this air, the adequacy of the duration of operation of the ventilation system, and the identification of leakage into the return plenum, either of outdoor or supply air. Keeping track of ventilation system performance is important not only in terms of maintaining good IAQ, but also making sure that this system continues to perform as intended after changes in building use. Information on the performance of the ventilation system is achieved by means of an automated sampling system that draws air from multiple locations and delivers it to both a carbon dioxide monitor and dew point sensor. The use of single shared sensors facilitates calibration checks as well as helps to guarantee data integrity. This approach to monitoring a building's ventilation system offers the possibility of achieving sustainable performance of this important aspect of good IAQ.

  17. Chemical Characterization of Dew Water Collected in Different Geographic Regions of Poland

    Directory of Open Access Journals (Sweden)

    Jacek Namieśnik

    2008-06-01

    Full Text Available The results of a dew monitoring program performed in Poland with the aim to outline the chemical composition of dew water in meteorological context are presented. Dew samples were collected from eight measurement stations from August 2004 to November 2006. Taking into account the type of land use and characteristics of pollutant emission, sampling sites were divided into the following categories: rural, coastal urban and inland urban stations. Selected anions and cations as well as formaldehyde and sum of phenols were determined. The average TIC (Total Inorganic Ionic Content values in dew samples ranged from 0.83 to 3.93 between individual stations with 10.9 meq/L as the highest daily value of TIC measured. The average TIC values observed in dew at all stations were at a similar level (2.46 meq/L when compared with hoarfrost (2.86 meq/L. However, these values were much higher in comparison with other kinds of atmospheric water like precipitation (wet only; 0.37 meq/L or fog/cloud (1.01 meq/L. The pH values of dew water ranged from 5.22 to 7.35 for urban coastal stations, from 5.67 to 8.02 for urban inland stations and from 4.16 to 8.76 for dew samples collected in the rural area. HCHO was found in 97 % of dew samples, with concentrations ranging from 0.010 to 5.40 meq/L. Excluding stations near the seashore, where the contribution of Na+ and Cl- increased, the most important ions were sulphates. A very low contribution of NO3- and noticeable increase of Ca2+ which were not observed in the case of precipitation and fog water, were typical in all stations. The contribution of ammonium ion was two times higher at rural stations as a result of agricultural ammonia emissions. The strongest correlations were noticed between the sum of acidifying anions SO42- + NO3- and Ca2+ ion for all urban and rural stations. A very strong correlation was also observed for Na+ and Cl- ions in urban coastal stations, as a natural consequence of the location of these

  18. Determination of dew absorption by coffee plant through deuterium concentrations in leaf water

    Energy Technology Data Exchange (ETDEWEB)

    Leopoldo, P R [Faculdade de Ciencias Medicas e Biologicas de Botucatu (Brazil); Salati, E; Matsui, E [Centro de Energia Nuclear na Agricultura, Piracicaba (Brazil)

    1975-12-01

    The effect of dew falling on leaves on the water metabolism of the coffee plant (Coffea arabica) is examined. The use of natural stable isotopes variations in plant physiological studies is demonstrated. Water extracted from leaf samples is analysed by mass spectrometry. Analyses of deuterium concentrations in water extracted from plant leaves, dew and nutrient solutions are made. Determination of changes in deuterium concentration in the water of leaves from plants exposed to dew, compared with leaves not exposed to dew, is carried out. Results show that during daytime there is an enrichment in deuterium in water contained in the leaves, while at night the opposite occurs.

  19. Determination of dew absorption by coffee plant through deuterium concentrations in leaf water

    International Nuclear Information System (INIS)

    Leopoldo, P.R.; Salati, E.; Matsui, E.

    1975-01-01

    The effect of dew falling on leaves on the water metabolism of the coffee plant (Coffea arabica) is examined. The use of natural stable isotopes variations in plant physiological studies is demonstrated. Water extracted from leaf samples is analysed by mass spectrometry. Analyses of deuterium concentrations in water extracted from plant leaves, dew and nutrient solutions are made. Determination of changes in deuterium concentration in the water of leaves from plants exposed to dew, compared with leaves not exposed to dew, is carried out. Results show that during daytime there is an enrichment in deuterium in water contained in the leaves, while at night the opposite occurs [pt

  20. Effect of artificially-generated wind on removing guttation and dew ...

    African Journals Online (AJOL)

    DynabookSS

    2015-03-25

    Mar 25, 2015 ... wind on the formation and removal of guttation and dew droplets on rice leaves. ... Wind is thought to reduce the number of spores attached to rice plant and to promote removal of dew droplets on the leaves. Thus, the penetration of blast into ..... and the application for forecasting method of the rice blast.

  1. Winter Dew Harvest in Mexico City

    Directory of Open Access Journals (Sweden)

    Arias-Torres Jorge Ernesto

    2015-12-01

    Full Text Available This study presents experimental and theoretical results of winter dew harvest in México City in terms of condensation rate. A simplified theoretical model based on a steady-state energy balance on a radiator-condenser was fitted, as a function of the ambient temperature, the relative humidity and the wind velocity. A glass sheet and aluminum sheet white-painted were used as samples over the outdoor experiments. A good correlation was obtained between the theoretical and experimental data. The experimental results show that there was condensation in 68% of the winter nights on both condensers. The total winter condensed mass was 2977 g/m2 and 2888 g/m2 on the glass sheet and aluminum sheet white-painted, respectively. Thus, the condensed mass on the glass was only 3% higher than that on the painted surface. The maximum nightly dew harvests occurred during December, which linearly reduced from 50 g/m2 night to 22 g/m2 night as the winter months went by. The condensation occurred from 1:00 a.m. to 9:00 a.m., with maximum condensation rates between 6:00 a.m. and 7:00 a.m. The dew harvest can provide a partial alternative to the winter water shortage in certain locations with similar climates to the winter in Mexico City, as long as pollution is not significant.

  2. Large Dew water collectors in a village of S-Morocco (Idouasskssou)

    Science.gov (United States)

    Lekouch, I.; Clus, O.; Durand, M.; Lanfourmi, M.; Muselli, M.; Milimouk, I.; Beysens, D.

    2010-07-01

    With precipitations close to 227 mm/year in average, the coastal region of south Morocco presents a chronically shortage of drinkable and fresh water. Since 1994, in the Mirleft area (150 km south of Agadir), inhabitants are facing a critically drought event. In the year 2007, only 49 mm of rain was recorded. However, measurements in Mirleft in the same year, showed that the dew yield was on order of 40 % of rain fall. In order to show to the local population the interest of recovering dew water in addition to rain water, a small nearby village (Idouasskssou, 8 km SE of Mirleft) was equipped with three pilot condensers of 136 m2 total surface area. In order to ensure a good integration of the project by the village inhabitants, a local organization (Association IMRJANE) collaborated to the project. A concrete tank at ground level with a flat horizontal surface, easily accessible for inhabitants and also a model for traditional Morocco terrace roofings, has been equipped with two lines of condensers (40.6 m²). All roofing materials were from local shops. Only the special radiative and hydrophilic coating was coming from non local resources (see www.opur.fr). The top of a second tank (aside the first one) was renovated and covered with a 21.2 m² two slopes steel roof, insulated and painted with the special dew coating as above. These roofs represent a condensation surface comparable to that of a very little house. A third condenser, with 73.8 m² surface area, was implemented directly on the ground, ensuring minimal work and very cheap implementation costs. Dew was collected and measured in one of the concrete tanks. The water production during 6 months, from 15-12-2008 to 31-07-2009 (137 dew events, 47 % of days) was more than 3800 L (more than 0.2 mm/dew day). It is important to note that, while the devices are specifically designed to condense dew water, they also harvest rain and fog as well, thus providing to the population a valuable water resource.

  3. On the contribution of atmospheric moisture to dew formation

    Science.gov (United States)

    Garratt, J. R.; Segal, M.

    1988-09-01

    The relative contributions of dewfall (a flux of water vapour from air to surface) and distillation (a flux of water vapour from soil to canopy) to dew formation on closed canopy and bare soil surfaces are assessed, and the dependence of dew amount upon wind speed, absolute temperature, atmospheric stability, relative humidity, soil characteristics and cloudiness, all of which are significant factors, is evaluated. Some of these evaluations provide refinements to similar ones given in Monteith (1961). High dewfall rates are usually ≲0.06 mm hr-1 over canopy or bare soil, though upon a canopy under soil-saturated and air-saturated conditions, rates of dew formation may reach 0.07 0.09 mm hr-1 with contributions from distillation. Various sets of observations are reanalyzed to illustrate the importance of the horizontal advection of moisture in the nocturnal boundary layer (NBL) to observed high rates of dew formation arising from the atmospheric contribution of water vapour (dewfall). These locally observed high dewfall rates must be the result of small-scale or mesoscale horizontal advection of moisture in the NBL, since the humidity changes within the typically shallow NBL required to balance the loss of water at the surface are not observed. Over extensive areas of uniform surface (horizontal scales ≫10 km), such continuously high dewfall rates could only be balanced by a local supply of atmospheric moisture since advection of moisture would necessarily be small.

  4. Influence of Gas Atmosphere Dew Point on the Galvannealing of CMnSi TRIP Steel

    Science.gov (United States)

    Cho, Lawrence; Kim, Myung Soo; Kim, Young Ha; De Cooman, Bruno C.

    2013-11-01

    The Fe-Zn reaction occurring during the galvannealing of a Si-bearing transformation-induced plasticity (TRIP) steel was investigated by field-emission electron probe microanalysis and field-emission transmission electron microscopy. The galvannealing was simulated after hot dipping in a Zn bath containing 0.13 mass pct Al at 733 K (460 °C). The galvannealing temperature was in the range of 813 K to 843 K (540 °C to 570 °C). The kinetics and mechanism of the galvannealing reaction were strongly influenced by the gas atmosphere dew point (DP). After the galvannealing of a panel annealed in a N2+10 pct H2 gas atmosphere with low DPs [213 K and 243 K (-60 °C and -30 °C)], the coating layer consisted of δ (FeZn10) and η (Zn) phase crystals. The Mn-Si compound oxides formed during intercritical annealing were present mostly at the steel/coating interface after the galvannealing. Galvannealing of a panel annealed in higher DP [263 K and 273 K, and 278 K (-10 °C, 0 °C, and +5 °C)] gas atmospheres resulted in a coating layer consisting of δ and Г (Fe3Zn10) phase crystals, and a thin layer of Г 1 (Fe11Zn40) phase crystals at the steel/coating interface. The Mn-Si oxides were distributed homogeneously throughout the galvannealed (GA) coating layer. When the surface oxide layer thickness on panels annealed in a high DP gas atmosphere was reduced, the Fe content at the GA coating surface increased. Annealing in a higher DP gas atmosphere improved the coating quality of the GA panels because a thinner layer of oxides was formed. A high DP atmosphere can therefore significantly contribute to the suppression of Zn-alloy coating defects on CMnSi TRIP steel processed in hot dip galvanizing lines.

  5. Uncertainty Evaluation of the New Setup for Measurement of Water-Vapor Permeation Rate by a Dew-Point Sensor

    Science.gov (United States)

    Hudoklin, D.; Šetina, J.; Drnovšek, J.

    2012-09-01

    The measurement of the water-vapor permeation rate (WVPR) through materials is very important in many industrial applications such as the development of new fabrics and construction materials, in the semiconductor industry, packaging, vacuum techniques, etc. The demand for this kind of measurement grows considerably and thus many different methods for measuring the WVPR are developed and standardized within numerous national and international standards. However, comparison of existing methods shows a low level of mutual agreement. The objective of this paper is to demonstrate the necessary uncertainty evaluation for WVPR measurements, so as to provide a basis for development of a corresponding reference measurement standard. This paper presents a specially developed measurement setup, which employs a precision dew-point sensor for WVPR measurements on specimens of different shapes. The paper also presents a physical model, which tries to account for both dynamic and quasi-static methods, the common types of WVPR measurements referred to in standards and scientific publications. An uncertainty evaluation carried out according to the ISO/IEC guide to the expression of uncertainty in measurement (GUM) shows the relative expanded ( k = 2) uncertainty to be 3.0 % for WVPR of 6.71 mg . h-1 (corresponding to permeance of 30.4 mg . m-2. day-1 . hPa-1).

  6. Estimating dew formation in rice, using seasonally averaged diel patterns of weather variables

    NARCIS (Netherlands)

    Luo, W.; Goudriaan, J.

    2004-01-01

    If dew formation cannot be measured it has to be estimated. Available simulation models for estimating dew formation require hourly weather data as input. However, such data are not available for places without an automatic weather station. In such cases the diel pattern of weather variables might

  7. Modeling the condensation of sulfuric acid and water on the cylinder liner of a large two-stroke marine diesel engine

    DEFF Research Database (Denmark)

    Cordtz, Rasmus Faurskov; Mayer, Stefan; Eskildsen, Svend S.

    2018-01-01

    how fuel sulfur content, charge air humidity and liner temperature variations affects the deposition of water and sulfuric acid at low load operation. A phenomenological engine model is applied to simulate the formation of cylinder/bulk gas combustion products and dew points comply with H2O–H2SO4...

  8. KEY COMPARISON Report to the CCT on key comparison EUROMET.T-K6 (EUROMET Project no. 621): Comparison of the realizations of local dew/frost-point temperature scales in the range -50 °C to +20 °C

    Science.gov (United States)

    Heinonen, Martti

    2010-01-01

    The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. Effects of sand burial on dew deposition on moss soil crust in a revegetated area of the Tennger Desert, Northern China

    Science.gov (United States)

    Jia, Rong-liang; Li, Xin-rong; Liu, Li-chao; Pan, Yan-xia; Gao, Yan-hong; Wei, Yong-ping

    2014-11-01

    Sand burial and dew deposition are two fundamental phenomena profoundly influencing biological soil crusts in desert areas. However, little information is available regarding the effects of sand burial on dew deposition on biological soil crusts in desert ecosystems. In this study, we evaluated the effects of sand burial at depths of 0 (control), 0.5, 1, 2 and 4 mm on dew formation and evaporation of three dominant moss crusts in a revegetated area of the Tengger Desert (Northern China) in 2010. The results revealed that sand burial significantly decreased the amount of dew deposited on the three moss crust types by acting as a semi-insulator retarding the dew formation and evaporation rates. The changes in surface temperature cannot fully explain the variations of the formation and evaporation rates of dew by moss crusts buried by sand. The extension of dew retention time was reflected by the higher dew ratios (the ratio of dew amount at a certain time to the maximum value in a daily course) in the daytime, and may to some extent have acted as compensatory mechanisms that diminished the negative effects of the reduction of dew amount induced by sand burial of moss crusts. The resistances to reduction of dewfall caused by sand burial among the three moss crusts were also compared and it was found that Bryum argenteum crust showed the highest tolerance, followed by crusts dominated by Didymodon vinealis and Syntrichia caninervis. This sequence corresponds well with the successional order of the three moss crusts in the revegetated area, thereby suggesting that resistance to reduction of dewfall may act as one mechanism by which sand burial drives the succession of moss crusts in desert ecosystems. This side effect of dew reduction induced by sand burial on biological soil crusts should be considered in future ecosystem construction and management of desert area.

  10. Performance of operational radiosonde humidity sensors in direct comparison with a chilled mirror dew-point hygrometer and its climate implication

    Science.gov (United States)

    Wang, Junhong; Carlson, David J.; Parsons, David B.; Hock, Terrence F.; Lauritsen, Dean; Cole, Harold L.; Beierle, Kathryn; Chamberlain, Edward

    2003-08-01

    This study evaluates performance of humidity sensors in two widely used operational radiosondes, Vaisala and Sippican (formally VIZ), in comparison with a research quality, and potentially more accurate, chilled mirror dew-point hygrometer named ``Snow White''. A research radiosonde system carrying the Snow White (SW) hygrometer was deployed in the Oklahoma panhandle and at Dodge City, KS during the International H2O Project (IHOP_2002). A total of sixteen sondes were launched with either Vaisala RS80 or Sippican VIZ-B2 radiosondes on the same balloons. Comparisons of humidity data from the SW with Vaisala and Sippican data show that (a) Vaisala RS80-H agrees with the SW very well in the middle and lower troposphere, but has dry biases in the upper troposphere (UT), (b) Sippican carbon hygristor (CH) has time-lag errors throughout the troposphere and fails to respond to humidity changes in the UT, sometimes even in the middle troposphere, and (c) the SW can detect cirrus clouds near the tropopause and possibly estimate their ice water content (IWC). The failure of CH in the UT results in significant and artificial humidity shifts in radiosonde climate records at stations where a transition from VIZ to Vaisala radiosondes has occurred.

  11. Modelling of temporal and spatial evolution of sulphur oxides and sulphuric acid under large, two-stroke marine engine-like conditions using integrated CFD-chemical kinetics

    DEFF Research Database (Denmark)

    Pang, Kar Mun; Karvounis, Nikolas; Walther, Jens Honore

    2017-01-01

    that the flameimpinges at the cylinder liner near top dead centre. The gas is cooled rapidly by the wall temperatureand H2SO4 is produced in the region where the local temperature is less than 600 K. Based on the fluegas correlation, the acid dew point temperature is higher than the wall temperature, suggesting...

  12. Novel ideas for maximising dew collection to aid plant establishment to combat desertification and restore degraded dry and arid lands

    Science.gov (United States)

    Kotzen, Benz

    2014-05-01

    This paper focuses on the potential of dew to provide water to plants and potentially to people as well in remote and difficult to reach areas where rainfall and underground water cannot be harvested. The combat of desertification and the restoration of degraded and desertified dry and arid lands has never been more urgent. A key practical component of this strategy is the restoration of habitat with planting. But for habitat and planting to survive there needs to be an adequate supply of water. In most cases providing water to the plant's roots is vital. In some areas where habitats have been destroyed, sufficient water is immediately available, for example through seasonal rainfall, or it can be harvested to concentrate adequate supplies of water to the roots. However, in arid and hyper arid areas, as well as in some dryland areas, a consistent and adequate supply of water cannot be provided by any conventional proven method. Thus, as the need to combat desertification and to restore desertified dry and arid land increases, so the need to find novel methods of establishing and maintaining planting and thus habitat increases. In more traditional land management scenarios this can be achieved through manipulating landform on a micro and macro scale, for example, by creating catchments, thereby collecting precipitation and directing it to the plants. Where this cannot be done, other means of water supply are usually required. Bainbridge (2007) and others have shown that supplying water to plants is possible through a number of traditional methods, for example, using clay pots. But most of these techniques require an introduced source of water, for example, obtained through water harvesting methods or by delivering water to site in tanks and by water bowser. This can work but requires continuous manpower. It is expensive and can be physically prohibitive in areas where access is difficult and/or remote. The concept of using dew to supply water in drylands is not new

  13. Impact of Continuous Cropping on the Diurnal Range of Dew Point Temperature during the Foliar Expansion Period of Annual Crops on the Canadian Prairies

    Directory of Open Access Journals (Sweden)

    Bharat M. Shrestha

    2016-01-01

    Full Text Available It is important to increase our knowledge of the role of land use in changing the regional climate. This study asked, “Has the increase in continuous cropping over the past 50 years on the Canadian Prairies influenced the daily mean and range of morning dew point temperatures (Td during the foliar expansion period (from mid-June to mid-July of annual field crops?” We found that there has been a general increase in the decadal average of mean daily Td and in the range of morning Td from the 1960s to the 2000s. The increase in the observed range of Td between the daily minimum value, which typically occurs near sunrise, and the late morning peak was found to be related to the increase in annual crop acreage and consequent decrease in summerfallow area. The relationship was more significant in the subhumid climatic zone than in the semiarid climatic zone, and it was influenced by whether the region was experiencing either wet, normal, or dry conditions.

  14. Dew water effects on leaf water using a stable isotope approach

    Science.gov (United States)

    Kim, K.; Lee, X.

    2009-12-01

    The presence of dew is a common meteorological phenomenon in field conditions and takes into account for significant portion of hydrologic processes in terrestrial ecosystems. The isotope composition of leaf water plays an important role in the isotopic water and carbon fluxes between terrestrial plants and the atmosphere. However, the consequence of dew formation in the plant-atmosphere relations has been ignored in many studies. The objective of this study is to improve our understanding of environmental and biological controls on the leaf water in equilibrium with dew water through laboratory experiments. Five species of plants (soybean, corn, sorghum, wheat, cotton) were grown hydroponically with water of a known isotopic content in a greenhouse. On the day of the experiment, they were first moved to ambient environment in full sunlight for at least 6 hr and then into a dark container inside the lab for up to 48 hr in which water vapor isotope ratios, temperature, and humidity were controlled. This arrangement created a step change in the forcing on the plant isotopic exchange. Leaves were sampled prior to the transfer to the dark container and 6 more times every 4 - 12 hr over the experiment. Humidity inside the container was saturated to mimic dew events in field conditions. Water from the leaf samples was extracted by a vacuum line and was analyzed for both δD and δ18O. The dataset will allow us to evaluate leaf water isotopic theories by exploring the transitions of the isotopic ratio of leaf water in response to the step change. Specifically, we are interested in whether the stomatal opening is an effective pathway for gaseous exchange in total darkness and how the transitional behaviors of the isotopic ratio of leaf water differ between the C3 and C4 photosynthesis pathways.

  15. Dew formation on the surface of biological soil crusts in central European sand ecosystems

    Directory of Open Access Journals (Sweden)

    T. Fischer

    2012-11-01

    Full Text Available Dew formation was investigated in three developmental stages of biological soil crusts (BSC, which were collected along a catena of an inland dune and in the initial substrate. The Penman equation, which was developed for saturated surfaces, was modified for unsaturated surfaces and used for prediction of dewfall rates. The levels of surface saturation required for this approach were predicted using the water retention functions and the thicknesses of the BSCs. During a first field campaign (2–3 August 2011, dewfall increased from 0.042 kg m−2 for the initial sandy substrate to 0.058, 0.143 and 0.178 kg m−2 for crusts 1 to 3, respectively. During a second field campaign (17–18 August 2011, where dew formation was recorded in 1.5 to 2.75-h intervals after installation at 21:30 CEST, dewfall increased from 0.011 kg m−2 for the initial sandy substrate to 0.013, 0.028 and 0.055 kg m−2 for crusts 1 to 3, respectively. Dewfall rates remained on low levels for the substrate and for crust 1, and decreased overnight for crusts 2 and 3 (with crust 3 > crust 2 > crust 1 throughout the campaign. Dew formation was well reflected by the model response. The suggested mechanism of dew formation involves a delay in water saturation in near-surface soil pores and extracellular polymeric substances (EPS where the crusts were thicker and where the water capacity was high, resulting in elevated vapor flux towards the surface. The results also indicate that the amount of dewfall was too low to saturate the BSCs and to observe water flow into deeper soil. Analysis of the soil water retention curves revealed that, despite the sandy mineral matrix, moist crusts clogged by swollen EPS pores exhibited a clay-like behavior. It is hypothesized that BSCs gain double benefit from suppressing their competitors by runoff generation and from improving their water supply by dew collection. Despite higher amounts of dew, the

  16. Miniaturised Optical Fibre Sensor for Dew Detection Inside Organ Pipes

    Directory of Open Access Journals (Sweden)

    Francesco Baldini

    2008-01-01

    Full Text Available A new optical sensor for the continuous monitoring of the dew formation inside organ pipes was designed. This aspect is particularly critical for the conservation of organs in unheated churches since the dew formation or the condensation on the pipe surfaces can contribute to many kinds of physical and chemical disruptive mechanisms. The working principle is based on the change in the reflectivity which is observed on the surface of the fibre tip, when a water layer is formed on its distal end. Intensity changes of the order of 35% were measured, following the formation of the water layer on the distal end of a 400/430 μm optical fibre. Long-term tests carried out placing the fibre tip inside the base of an in-house-made metallic foot of an organ pipe located in an external environment revealed the consistency of the proposed system.

  17. A re-entrant resonator for the measurement of phase boundaries: dew points for {0.4026CH4 + 0.5974C3H8}

    International Nuclear Information System (INIS)

    Kandil, Mohamed E.; Marsh, Kenneth N.; Goodwin, Anthony R.H.

    2005-01-01

    For a natural gas and, especially, retrograde condensates, it is important for exploration and production that the (liquid + gas) phase boundary be known along with the ratio of liquid-to-gas volumes within the (liquid + gas) two-phase region. These fluid properties can be measured by a plethora of methods and here we report a method based on the measurement of the resonance frequency of the lowest order inductive-capacitance mode of a re-entrant cavity capable of operating at temperatures up to 473 K and pressures below 20 MPa. This instrument has been used to measure, at T 4 + 0.5974C 3 H 8 }. The measured dew pressures differ by less than 0.5 % from values obtained by interpolation of those reported in the literature, which were determined from measurements with experimental techniques that suffer from quite different potential sources of systematic error than the radio-frequency resonator used here. Dew pressures estimated from both NIST 14 and the Peng-Robinson equation of state lie within <±1 % of our results at temperature between (315 and 337) K while predictions obtained from the Soave Redlich Kwong cubic equation of state deviate from our results by 0.4 % at T = 315 K and these absolute differences increase smoothly with increasing temperature to be -2.4 % at T = 337 K

  18. Reprises textuelles dans The Dew Breaker d’Edwidge Danticat Rewriting / Reprising in Edwidge Danticat’s The Dew Breaker

    Directory of Open Access Journals (Sweden)

    Corinne Duboin

    2007-01-01

    Full Text Available In her recent novel, The Dew Breaker (2004, Haitian-American writer Edwidge Danticat weaves together the lives of her bruised Haitian characters and their torturer, a former Tonton Macoute, all in exile in the US. Seven of the nine chapters were previously published as separate short stories and have been rearranged to form a novel. The reader is then led to unravel a narrative tangle made of many threads. The disparate nature of the book, its non-linear narrative, the plurality of stories and voices, the gaps in a fragmented, elliptic text all bear witness to an alternative approach to creative writing. Like a seamstress, the novelist pieces together individual stories, connecting them as the multifarious facets of a great whole. In the wake of francophone Haitian writers (namely Jacques Roumain, the author of Masters of the Dew, and Jacques Stephen Alexis who wrote General Sun, My Brother, Edwidge Danticat fictionalizes the traumatic history of a people confronted with violence and terror and engages in a complex intertextual game. Combining ethics and aesthetics, temporal and textual memory, the novelist explores facts and, rather than giving answers, raises difficult questions. Her characters, whether victims or perpetrators, all strive to free themselves from a haunting past: is it ever possible to forgive so as to heal the pain? Can one make amends for the harm that has been done to victims who seek redress?

  19. Water harvest via dewing.

    Science.gov (United States)

    Lee, Anna; Moon, Myoung-Woon; Lim, Hyuneui; Kim, Wan-Doo; Kim, Ho-Young

    2012-07-10

    Harvesting water from humid air via dewing can provide a viable solution to a water shortage problem where liquid-phase water is not available. Here we experimentally quantify the effects of wettability and geometry of the condensation substrate on the water harvest efficiency. Uniformly hydrophilic surfaces are found to exhibit higher rates of water condensation and collection than surfaces with lower wettability. This is in contrast to a fog basking method where the most efficient surface consists of hydrophilic islands surrounded by hydrophobic background. A thin drainage path in the lower portion of the condensation substrate is revealed to greatly enhance the water collection efficiency. The optimal surface conditions found in this work can be used to design a practical device that harvests water as its biological counterpart, a green tree frog, Litoria caerulea , does during the dry season in tropical northern Australia.

  20. Live performance of male broilers subjected to constant or increasing air velocities at moderate temperatures with a high dew point.

    Science.gov (United States)

    Dozier, W A; Lott, B D; Branton, S L

    2005-08-01

    This study examined the effects of varying air velocities vs. a constant air velocity with a cyclic temperature curve of 25-30-25 degrees C and a dew point of 23 degrees C on broilers from 28 to 49 d of age. Four replicate trials were conducted. In each trial, 742 male broilers were randomly allocated to 6 floor pens or 2 air velocity tunnels, with each tunnel consisting of 4 pens. Bird density, feeder, and waterer space were similar across all pens (53 birds/ pen; 0.07 m2/bird). The treatments were control (still air), constant air velocity of 120 m/min, and increasing air velocity (90 m/min from 28 to 35 d, 120 m/min from 36 to 42 d, and 180 m/min from 43 to 49 d). Birds grown in a still air environment gained less weight, consumed less feed, and converted feed less efficiently between 28 and 49 d than birds subjected to moving air (constant or increasing). Growth responses between the air velocity treatments were similar from 28 to 35 and 36 to 42 d of age. Increasing air velocity to 180 m/min improved (P < or = 0.02) the growth rate of broilers from 43 to 49 d of age over birds receiving an air velocity of 120 m/min, but the incidence of mortality was not affected. These results provide evidence that increasing air velocity from 120 to 180 m/min is beneficial to broilers weighing 2.5 kg or greater when exposed to moderate temperatures.

  1. Inertially Stabilized Platforms for Precision Pointing Applications to Directed-Energy Weapons and Space-Based Lasers (Preprint)

    National Research Council Canada - National Science Library

    Negro, J; Griffin, S

    2006-01-01

    .... This article addresses directed-energy-weapon (DEW) precision pointing requirements and implementation alternatives in the context of strapdown and stable-platform inertial-reference technologies...

  2. Study of temperature, air dew point temperature and reactant flow effects on proton exchange membrane fuel cell performances using electrochemical spectroscopy and voltammetry techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wasterlain, S.; Hissel, D. [FC LAB, Techn' Hom, rue Thierry Mieg, 90010 Belfort Cedex (France); FEMTO-ST (UMR CNRS 6174), ENISYS Department, University of Franche-Comte, Techn' Hom, rue Thierry Mieg, 90010 Belfort Cedex (France); Candusso, D.; Harel, F. [FC LAB, Techn' Hom, rue Thierry Mieg, 90010 Belfort Cedex (France); INRETS, The French National Institute for Transport and Safety Research, Techn' Hom, rue Thierry Mieg, 90010 Belfort Cedex (France); Bergman, P.; Menard, P.; Anwar, M. [University of Connecticut, Connecticut Global Fuel Cell Center Department of Electrical and Computer Engineering, 44 Weaver Road, Unit 5233, Storrs, CT 06269-5233 (United States)

    2010-02-15

    A single PEMFC has been operated by varying the assembly temperature, the air dew point temperature and the anode/cathode stoichiometry rates with the aim to identify the parameters and combinations of factors affecting the cell performance. Some of the experiments were conducted with low humidified reactants (relative humidity of 12%). The FC characterizations tests have been conducted using in situ electrochemical methods based on load current and cell voltage signal analysis, namely: polarization curves, EIS measurements, cyclic and linear sweep voltammetries (CV and LSV). The impacts of the parameters on the global FC performances were observed using the polarization curves whereas EIS, CV and LSV test results were used to discriminate the different voltage loss sources. The test results suggest that some parameter sets allow maximal output voltages but can also induce material degradation. For instance, higher FC temperature and air flow values can induce significant electrical efficiency benefits, notably by increasing the reversible potential and the reaction kinetics. However, raising the cell temperature can also gradually dry the FC and increase the risk of membrane failure. LSV has also shown that elevated FC temperature and relative humidity can also accelerate the electrolyte degradation (i.e. slightly higher fuel crossover rate) and reduce the lifetime consequently. (author)

  3. Study of temperature, air dew point temperature and reactant flow effects on proton exchange membrane fuel cell performances using electrochemical spectroscopy and voltammetry techniques

    Science.gov (United States)

    Wasterlain, S.; Candusso, D.; Hissel, D.; Harel, F.; Bergman, P.; Menard, P.; Anwar, M.

    A single PEMFC has been operated by varying the assembly temperature, the air dew point temperature and the anode/cathode stoichiometry rates with the aim to identify the parameters and combinations of factors affecting the cell performance. Some of the experiments were conducted with low humidified reactants (relative humidity of 12%). The FC characterizations tests have been conducted using in situ electrochemical methods based on load current and cell voltage signal analysis, namely: polarization curves, EIS measurements, cyclic and linear sweep voltammetries (CV and LSV). The impacts of the parameters on the global FC performances were observed using the polarization curves whereas EIS, CV and LSV test results were used to discriminate the different voltage loss sources. The test results suggest that some parameter sets allow maximal output voltages but can also induce material degradation. For instance, higher FC temperature and air flow values can induce significant electrical efficiency benefits, notably by increasing the reversible potential and the reaction kinetics. However, raising the cell temperature can also gradually dry the FC and increase the risk of membrane failure. LSV has also shown that elevated FC temperature and relative humidity can also accelerate the electrolyte degradation (i.e. slightly higher fuel crossover rate) and reduce the lifetime consequently.

  4. Final report on EURAMET.T-K6.1: Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70 °C to +20 °C

    Science.gov (United States)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2013-01-01

    As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Measurements for the determination of acid dew point and SO[sub 3] concentration in the flue gas of utility boilers

    Energy Technology Data Exchange (ETDEWEB)

    Derichs, W.; Menden, W.; Ebel, P.K. (RWE Energie AG, Bergheim (Germany))

    1991-10-01

    Until now, the well-known measuring systems for determining acid dewpoint have been applied primarily to flue gases from oil-fired combustion. Using an acid dewpoint measuring system which has now been available on the market for some time, it is possible to measure the acid dewpoint reliably and continuously in flue gas from coal-fired combustion, with low SO[sub 3] concentrations. This measuring system has also been used for flue gas from which the dust and sulphur have been removed as well as for untreated flue gas of conventional combustion systems with gas, oil, hard coal and brown coal firing and also in fluidized bed combustion systems. 6 refs., 11 figs., 2 tabs.

  6. Phase behavior of (CO2 + methanol + lauric acid) system

    International Nuclear Information System (INIS)

    Ferreira, Franciele M.; Ramos, Luiz P.; Ndiaye, Papa M.; Corazza, Marcos L.

    2011-01-01

    Highlights: → We measured SVL, LLE and VLE for the binary system {lauric acid + methanol + CO 2 }. → Bubble point and dew point were measured at high pressures. → The experimental data were modeled using the Peng-Robinson equation of state with the classical van der Waals mixing rule. - Abstract: In this study the phase equilibrium behaviors of the binary system (CO 2 + lauric acid) and the ternary system (CO 2 + methanol + lauric acid) were determined. The static synthetic method, using a variable-volume view cell, was employed to obtain the experimental data in the temperature range of (293 to 343) K and pressures up to 24 MPa. The mole fractions of carbon dioxide were varied according to the systems as follows: (0.7524 to 0.9955) for the binary system (CO 2 + lauric acid); (0.4616 to 0.9895) for the ternary system (CO 2 + methanol + lauric acid) with a methanol to lauric acid molar ratio of (2:1); and (0.3414 to 0.9182) for the system (CO 2 + methanol + lauric acid) with a methanol to lauric acid molar ratio of (6:1). For these systems (vapor + liquid), (liquid + liquid), (vapor + liquid + liquid), and (solid + fluid) transitions were observed. The phase equilibrium data obtained for the systems were modeled using the Peng-Robinson equation of state with the classical van der Waals mixing rule with a satisfactory correlation between experimental and calculated values.

  7. CLINSULF sub-dew-point process for sulphur recovery

    Energy Technology Data Exchange (ETDEWEB)

    Heisel, M.; Marold, F.

    1988-01-01

    In a 2-reactor system, the CLINSULF process allows very high sulphur recovery rates. When operated at 100/sup 0/C at the outlet, i.e. below the sulphur solidification point, a sulphur recovery rate of more than 99.2% was achieved in a 2-reactor series. Assuming a 70% sulphur recovery in an upstream Claus furnace plus sulphur condenser, an overall sulphur recovery of more than 99.8% results for the 2-reactor system. This is approximately 2% higher than in conventional Claus plus SDP units, which mostly consist of 4 reactors or more. This means the the CLINSULF SSP process promises to be an improvement both in respect of efficiency and low investment cost.

  8. Study on dew point evaporative cooling system with counter-flow configuration

    KAUST Repository

    Lin, J.; Thu, K.; Bui, T.D.; Wang, R.Z.; Ng, Kim Choon; Chua, K.J.

    2015-01-01

    coefficient along the channel. Parametric studies are conducted at different geometric and operating conditions. For the conditions evaluated, the study reveals that (1) the saturation point of the working air occurs at a fixed point regardless of the inlet

  9. Accelerated successive substitution schemes for bubble-point and dew-point calculations

    Energy Technology Data Exchange (ETDEWEB)

    Peng, D.-Y. (Univ. of Saskatchewan, Saskatoon, SK (Canada))

    1991-08-01

    Phase equilibrium calculations form an important part of the process design operations in the hydrocarbon and petroleum industry. The accelerated successive substitution (SS) algorithms developed by Mehra et al. (1983) for flash calculations have been extended to the prediction of saturation points. A transformation matrix which is used to calculate the acceleration parameter has been rewritten in a form that is applicable at the saturation conditions. Simple equations for estimating the initial values and recursive formulae according to which the iterates can be updated are presented. The proposed schemes were compared with the conventional SS method and a multivariate Newton's method. The comparison suggests that the accelerated SS schemes are more tolerant of poor initial values and sometimes more efficient than Newton's method. The features of the acceleration schemes and those of the empirical equations developed in this study are illustrated using three hydrocarbon mixtures: a 5-component mixture of n-alkanes, a typical natural gas system, and a volatile oil. 19 refs., 6 figs., 6 tabs.

  10. Effects of Engineered Wettability on the Efficiency of Dew Collection.

    Science.gov (United States)

    Gerasopoulos, Konstantinos; Luedeman, William L; Ölçeroglu, Emre; McCarthy, Matthew; Benkoski, Jason J

    2018-01-31

    Surface wettability plays an important role in dew collection. Nucleation is faster on hydrophilic surfaces, while droplets slide more readily on hydrophobic surfaces. Plants and animals in coastal desert environments appear to overcome this trade-off through biphilic surfaces with patterned wettability. In this study, we investigate the effects of millimeter-scale wettability patterns, mimicking those of the Stenocara beetle, on the rate of water collection from humid air. The rate of water collection per unit area is measured as a function of subcooling (ΔT = 1, 7, and 27 °C) and angle of inclination (from 10° to 90°). It is then compared for superbiphilic, hydrophilic, hydrophobic, and surperhydrophobic surfaces. For large subcooling, neither wettability nor tilt angle has a significant effect because the rate of condensation is so great. For 1 °C subcooling and large angles, hydrophilic surfaces perform best because condensation is the rate-limiting step. For low angles of inclination, superhydrophobic samples are best because droplet sliding is the rate-limiting step. Superbiphilic surfaces, in contrast to their superior fog collecting capabilities, generally collected dew at the slowest rate due to their inherent contact angle hysteresis. Theoretical considerations suggest that this finding may apply more generally to surfaces with patterned wettability.

  11. Effect of Different Growth Stages and Dew Period Length on Disease Development of Alternaria alternata as a Biological Control Agent for Convolvulus arvensis

    Directory of Open Access Journals (Sweden)

    E Zeidali

    2012-02-01

    Full Text Available Abstract Field bindweed is an important perinial weed of agricultural crops word-wide. There are plant pathogen fungus which could cause necrotic spots on the leaves and stems of convolvulus arvensis under natural coditions. In order to evaluate the effects of weed growth stage and length of dew period on disease development causes by Aletrnaria alternata and Fusarium sp. two expriments were performed in the greenhouse based on a completely randomized design in factorial arrangement with four replications during 2006-2007. Spore concentration for both experiments was 107 spores per ml of distilled water. In the first experiment, treatments were different growth stages of field bindweed (cotyledon, 4-leaf, 6-leaf, 9-11-leaf stages. Results showed that disease development in the fungus of A. alternata was higher than Fusarium sp. The most susceptable growth stage of field bindweed plants to A. alternata was 2-4-leave stage. The second expriment was performed in order to study the effect of dew period length (6, 12, 24 and 48 hour dew periods on disease development at 4-leaf growth stage of field bindweed. The maximum disease development and minimum weed dry weight were observed with application of the fungus of A. alternata at dew periods of 24 and 48 hour, however, plant damage was also observed with a length of 6 hours dew period.

  12. Automated calibration of laser spectrometer measurements of δ18 O and δ2 H values in water vapour using a Dew Point Generator.

    Science.gov (United States)

    Munksgaard, Niels C; Cheesman, Alexander W; Gray-Spence, Andrew; Cernusak, Lucas A; Bird, Michael I

    2018-06-30

    Continuous measurement of stable O and H isotope compositions in water vapour requires automated calibration for remote field deployments. We developed a new low-cost device for calibration of both water vapour mole fraction and isotope composition. We coupled a commercially available dew point generator (DPG) to a laser spectrometer and developed hardware for water and air handling along with software for automated operation and data processing. We characterised isotopic fractionation in the DPG, conducted a field test and assessed the influence of critical parameters on the performance of the device. An analysis time of 1 hour was sufficient to achieve memory-free analysis of two water vapour standards and the δ 18 O and δ 2 H values were found to be independent of water vapour concentration over a range of ≈20,000-33,000 ppm. The reproducibility of the standard vapours over a 10-day period was better than 0.14 ‰ and 0.75 ‰ for δ 18 O and δ 2 H values, respectively (1 σ, n = 11) prior to drift correction and calibration. The analytical accuracy was confirmed by the analysis of a third independent vapour standard. The DPG distillation process requires that isotope calibration takes account of DPG temperature, analysis time, injected water volume and air flow rate. The automated calibration system provides high accuracy and precision and is a robust, cost-effective option for long-term field measurements of water vapour isotopes. The necessary modifications to the DPG are minor and easily reversible. Copyright © 2018 John Wiley & Sons, Ltd.

  13. Is KCl(g) corrosive at temperatures above its dew point? Influence of KCl(g) on initial stages of the high temperature corrosion of 11% Cr steel at 600 C

    Energy Technology Data Exchange (ETDEWEB)

    Segerdahl, K.; Pettersson, J.; Svensson, J.E.; Johansson, L.G. [Dept. of Environmental Inorganic Chemistry, High Temperature Corrosion Centre, Chalmers Univ. of Technology, Goeteborg (Sweden)

    2004-07-01

    The influence of gaseous KCl on the high temperature oxidation of CrMoV11 1 (X20) steel at 600 C is reported. The sample temperature was above the dew point of KCl, the partial pressure of KCl being about 5ppm. The samples were investigated by a number of surface analytical techniques including grazing angle XRD, SEM/EDX, and SAM. CrMoV11 1 steel shows protective behaviour in clean dry O{sub 2} and O{sub 2}/H{sub 2}O environment because of the formation of a chromium-rich oxide ({alpha}-(Fe,Cr){sub 2}O{sub 3}). It is often considered that alkali salts accelerate the corrosion of steel only when present on the surface in solid or liquid form. In contrast, the present result shows that gaseous KCl is very corrosive, also in the absence of condensation. KCl(g) reacts with chromium in the scale, forming K{sub 2}CrO{sub 4}(s). This depletes the protective oxide in chromium and leads to the formation of non-protective hematite, Fe{sub 2}O{sub 3}. (orig.)

  14. An automated microlysimeter to study dew formation and evaporation in arid and semiarid regions

    NARCIS (Netherlands)

    Heusinkveld, B.G.; Berkowicz, S.M.; Jacobs, A.F.G.; Holtslag, A.A.M.; Hillen, W.C.A.M.

    2006-01-01

    The development of a simple and low-cost portable weighing microlysimeter that makes use of a load cell for automated recording and for studying daily dew formation, rate of accumulation, and subsequent evaporation in arid or semiarid regions during rainless seasons is presented. The sampling cup is

  15. What Is the Boiling Point and Heat of Vaporization of Sulfuric Acid?

    Science.gov (United States)

    Myers, R. Thomas

    1983-01-01

    Discusses the values presented in various handbooks for the boiling point and heat of vaporization of sulfuric acid, noting discrepencies. Analyzes various approaches to data presentation, discussing the data on sulfuric acid in light of the Trouton constant. Points out the need for a more critical use of tables. (JM)

  16. TFOS DEWS II Tear Film Report.

    Science.gov (United States)

    Willcox, Mark D P; Argüeso, Pablo; Georgiev, Georgi A; Holopainen, Juha M; Laurie, Gordon W; Millar, Tom J; Papas, Eric B; Rolland, Jannick P; Schmidt, Tannin A; Stahl, Ulrike; Suarez, Tatiana; Subbaraman, Lakshman N; Uçakhan, Omür Ö; Jones, Lyndon

    2017-07-01

    The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Actual state of plant decline phenomena due to acid rain and others

    International Nuclear Information System (INIS)

    Nakane, Kaneyuki

    1992-01-01

    The withering of pine trees in large number became remarkable around 1960, and though efforts have been exerted by scattering insecticide and removing withered trees, it is not yet stopped. Recently, as the cause of the withering of pine trees, the deterioration of the environment of pine tree growth, particularly the effect of atmospheric pollution, has been pointed out. In this study, the relation of the withering of pine trees to acid rain, fog and dew was examined. Pine trees are widely distributed in Hiroshima Prefecture in more than 40% of forest areas. The withering of pine trees tends to expand along new expressways. The correlation of the distribution of pine tree withering with atmospheric pollution utilizing remote sensing technique, the vitality of pine leaves, the acidity and the amount of adhering acid fallout on pine leaves, the acidity of rainwater, rain in forests, water infiltrated in soil and so on are reported. The pine trees in the coastal area of Seto Inland Sea wither, and those in inland area are relatively sound, therefore, atmospheric pollution is dominant in the withering of pine trees. (K.I.)

  18. Conditions for lowering the flue gas temperature; Foerutsaettning foer saenkning av roekgastemperatur

    Energy Technology Data Exchange (ETDEWEB)

    Nordling, Magnus

    2012-02-15

    In heat and power production, the efficiency of the power plant increases the larger share of heat from the flue gas that is converted to power. However, this also implies that the temperature of the heat exchanging surfaces is lowered. If the temperature is lowered to a temperature below the dew point of the flue gas, this would result in condensation of the gas, which in turn elevates the risk of serious corrosion attack on the surfaces where condensation occurs. Thus, it is important to determine the dew point temperature. One way of determining the dew point temperature is to use data on composition of the fuel together with operation parameters of the plant, thus calculating the dew point temperature. However, this calculation of the dew point is not so reliable, especially if hygroscopic salts are present. Therefore, for safety reasons, the temperature of the flue gas is kept well above the dew point temperature. This results in lowered over-all efficiency of the plant. It could also be expected that for a certain plant, some construction materials under certain operation conditions would have corrosion characteristics that may allow condensation on the surface without severe and unpredictable corrosion attack. However, by only using operation parameters and fuel composition, it is even harder to predict the composition of the condensate at different operation temperatures than to calculate the dew point temperature. If the dew point temperature was known with a greater certainty, the temperature of the flue gas could be kept lower, just above the estimated value of the dew point, without any increased risk for condensation. If, in addition, also the resulting composition of the condensate at different temperatures below the dew point is known, it can be predicted if the construction materials of the flue gas channel were compatible with the formed condensate. If they are compatible, the flue gas temperature can be further lowered from the dew point

  19. Investigation on the pinch point position in heat exchangers

    Science.gov (United States)

    Pan, Lisheng; Shi, Weixiu

    2016-06-01

    The pinch point is important for analyzing heat transfer in thermodynamic cycles. With the aim to reveal the importance of determining the accurate pinch point, the research on the pinch point position is carried out by theoretical method. The results show that the pinch point position depends on the parameters of the heat transfer fluids and the major fluid properties. In most cases, the pinch point locates at the bubble point for the evaporator and the dew point for the condenser. However, the pinch point shifts to the supercooled liquid state in the near critical conditions for the evaporator. Similarly, it shifts to the superheated vapor state with the condensing temperature approaching the critical temperature for the condenser. It even can shift to the working fluid entrance of the evaporator or the supercritical heater when the heat source fluid temperature is very high compared with the absorbing heat temperature. A wrong position for the pinch point may generate serious mistake. In brief, the pinch point should be founded by the iterative method in all conditions rather than taking for granted.

  20. A method for high accuracy determination of equilibrium relative humidity

    DEFF Research Database (Denmark)

    Jensen, O.M.

    2012-01-01

    This paper treats a new method for measuring equilibrium relative humidity and equilibrium dew-point temperature of a material sample. The developed measuring device is described – a Dew-point Meter – which by means of so-called Dynamic Dew-point Analysis permits quick and very accurate...

  1. Estimativa da duração do período de molhamento por orvalho em um ecossistema cacau Estimate of the duration of the wetness period by dew in a cocoa ecosystem

    Directory of Open Access Journals (Sweden)

    Hermes A. de Almeida

    2009-12-01

    Full Text Available O objetivo deste trabalho foi estimar a duração do período de molhamento por orvalho (DPM, entre 18 e 06 h, utilizando-se dois modelos empíricos: a o do número de horas com umidade relativa > a 97% (NHUR > 97% e b o da depressão do ponto de orvalho The objective of this study was to estimate the duration of wetness by dew (DWW, from 18 to 06 h, using two empirical models: a number of hours with relative air humidity > 97% (NHUR > 97% and b depression of the dew point 61%, although the percentage for winter and summer months was 80.8 and 15.8% respectively. The high statistical indexes observed here show the viability of the models for estimating, with high precision, the DWW in a cocoa ecosystem. The models are of easy application and operation, dispensing the utilization of sensors and of more complex methods. Howerer, they still need some adjustments to be used for other crops and conditions.

  2. Phase Envelope Calculations for Reservoir Fluids in the Presence of Capillary Pressure

    DEFF Research Database (Denmark)

    Lemus, Diego; Yan, Wei; Michelsen, Michael L.

    2015-01-01

    the bubble and dew point curves but also other quality lines with vapor fractions between 0 and 1. The algorithm has been used to calculate the phase envelopes of binary, multicomponent and reservoir fluid systems for pore radius from 10 to 50 nm. The presence of capillary pressure changes the saturation...... pressures in the whole phase envelope except at the critical point. The bubble point curve shows a negative change while the dew point curve shows positive and negative changes in the upper dew point branch and the lower dew point branch, respectively. In particular, the cricondentherm is also shifted...

  3. Dew Point Evaporative Comfort Cooling

    Science.gov (United States)

    2012-11-01

    Multiple DASs were installed at Fort Carson, and the data from all the sensors were stored and partially processed on Campbell Scientific Data Loggers. The...evaporative cooling technologies would be expected to easily overcome utility- scale water withdrawal rates. As an example, an evaluation of an...Ambient pressure Outdoor Setra 276 1% of full scale Pyranometer Horizontal Campbell Scientific CS300 5% of daily total The OAT measurement has an

  4. Influence of Gas Atmosphere Dew Point on the Selective Oxidation and the Reactive Wetting During Hot Dip Galvanizing of CMnSi TRIP Steel

    Science.gov (United States)

    Cho, Lawrence; Lee, Seok Jae; Kim, Myung Soo; Kim, Young Ha; De Cooman, Bruno C.

    2013-01-01

    The selective oxidation and reactive wetting of intercritically annealed Si-bearing CMnSi transformation-induced plasticity steels were investigated by high-resolution transmission electron microscopy. In a N2 + 10 pct H2 gas atmosphere with a dew point (DP) ranging from 213 K to 278 K (-60 °C to 5 °C), a continuous layer of selective oxides was formed on the surface. Annealing in a higher DP gas atmosphere resulted in a thinner layer of external oxidation and a greater depth of internal oxidation. The hot dipping was carried out in a Zn bath containing 0.22 mass pct Al, and the bath temperature was 733 K (460 °C). Coarse and discontinuous Fe2Al5- x Zn x grains and Fe-Zn intermetallics (ζ and δ) were observed at the steel/coating interface after the hot dip galvanizing (HDG) of panels were annealed in a low DP atmosphere 213 K (-60 °C). The Fe-Zn intermetallics were formed both in areas where the Fe2Al5- x Zn x inhibition layer had not been formed and on top of non-stoichiometric Fe-Al-Zn crystals. Poor wetting was observed on panels annealed in a low DP atmosphere because of the formation of thick film-type oxides on the surface. After annealing in higher DP gas atmospheres, i.e., 263 K and 278 K (-10 °C and 5 °C), a continuous and fine-grained Fe2Al5- x Zn x layer was formed. No Fe-Zn intermetallics were formed. The small grain size of the inhibition layer was attributed to the nucleation of the Fe2Al5- x Zn x grains on small ferrite sub-surface grains and the presence of granular surface oxides. A high DP atmosphere can therefore significantly contribute to the decrease of Zn-coating defects on CMnSi TRIP steels processed in HDG lines.

  5. Modeling the condensation of sulfuric acid and water on the cylinder liner of a large two-stroke marine diesel engine

    DEFF Research Database (Denmark)

    Cordtz, Rasmus Faurskov; Mayer, Stefan; Eskildsen, Svend S.

    2018-01-01

    Corrosive wear of cylinder liners in large two-stroke marine diesel engines that burn heavy fuel oil containing sulfur is coupled to the formation of gaseous sulfur trioxide (SO3) and subsequent combined condensation of sulfuric acid (H2SO4) and water (H2O) vapor. The present work seeks to address...... vapor liquid equilibrium. By assuming homogenous cylinder gas mixtures condensation is modeled using a convective heat and mass transfer analogy combined with realistic liner temperature profiles. Condensation of water is significantly altered by the liner temperature and charge air humidity while...... how fuel sulfur content, charge air humidity and liner temperature variations affects the deposition of water and sulfuric acid at low load operation. A phenomenological engine model is applied to simulate the formation of cylinder/bulk gas combustion products and dew points comply with H2O–H2SO4...

  6. DEWS (DEep White matter hyperintensity Segmentation framework): A fully automated pipeline for detecting small deep white matter hyperintensities in migraineurs.

    Science.gov (United States)

    Park, Bo-Yong; Lee, Mi Ji; Lee, Seung-Hak; Cha, Jihoon; Chung, Chin-Sang; Kim, Sung Tae; Park, Hyunjin

    2018-01-01

    Migraineurs show an increased load of white matter hyperintensities (WMHs) and more rapid deep WMH progression. Previous methods for WMH segmentation have limited efficacy to detect small deep WMHs. We developed a new fully automated detection pipeline, DEWS (DEep White matter hyperintensity Segmentation framework), for small and superficially-located deep WMHs. A total of 148 non-elderly subjects with migraine were included in this study. The pipeline consists of three components: 1) white matter (WM) extraction, 2) WMH detection, and 3) false positive reduction. In WM extraction, we adjusted the WM mask to re-assign misclassified WMHs back to WM using many sequential low-level image processing steps. In WMH detection, the potential WMH clusters were detected using an intensity based threshold and region growing approach. For false positive reduction, the detected WMH clusters were classified into final WMHs and non-WMHs using the random forest (RF) classifier. Size, texture, and multi-scale deep features were used to train the RF classifier. DEWS successfully detected small deep WMHs with a high positive predictive value (PPV) of 0.98 and true positive rate (TPR) of 0.70 in the training and test sets. Similar performance of PPV (0.96) and TPR (0.68) was attained in the validation set. DEWS showed a superior performance in comparison with other methods. Our proposed pipeline is freely available online to help the research community in quantifying deep WMHs in non-elderly adults.

  7. Investigation of selective oxidation in bake hardenable steel

    International Nuclear Information System (INIS)

    Madeira, Laureanny; Lins, Vanessa Cunha Freitas; Faria, Guilherme Augusto de; Guimaraes, Juliana Porto; Alvarenga, Evandro de Azevedo; Vilela, Jose Mario Carneiro

    2010-01-01

    The present work aims to characterize a steel bake hardenable (BH), annealed in three different dew points (-60°C, -30°C and 0°C), as the occurrence of selective oxidation, using the techniques of X-ray photo electronic spectroscopy (XPS), glow discharge optical emission spectroscopy (GDOES) and atomic force microscopy (AFM). The analysis by XPS showed that the alloying elements oxidized at different intensities for each dew point. Analysis by GDOES revealed that the surface and subsurface concentrations of these elements also varied with the dew point. The AFM images revealed that the size and shape of the oxides were different for each dew point. At the dew points of -30°C and -60°C the formation of oxides was local, while at 0°C the growth of oxides occurred uniform y on the surface of steels. (author)

  8. Controlled humidity gas circulators

    International Nuclear Information System (INIS)

    Gruner, S.M.

    1981-01-01

    A programmable circulator capable of regulating the humidity of a gas stream over a wide range of humidity is described. An optical dew-point hygrometer is used as a feedback element to control the addition or removal of water vapor. Typical regulation of the gas is to a dew-point temperature of +- 0.2 0 C and to an accuracy limited by the dew-point hygrometer

  9. Equivalence-point electromigration acid-base titration via moving neutralization boundary electrophoresis.

    Science.gov (United States)

    Yang, Qing; Fan, Liu-Yin; Huang, Shan-Sheng; Zhang, Wei; Cao, Cheng-Xi

    2011-04-01

    In this paper, we developed a novel method of acid-base titration, viz. the electromigration acid-base titration (EABT), via a moving neutralization boundary (MNR). With HCl and NaOH as the model strong acid and base, respectively, we conducted the experiments on the EABT via the method of moving neutralization boundary for the first time. The experiments revealed that (i) the concentration of agarose gel, the voltage used and the content of background electrolyte (KCl) had evident influence on the boundary movement; (ii) the movement length was a function of the running time under the constant acid and base concentrations; and (iii) there was a good linearity between the length and natural logarithmic concentration of HCl under the optimized conditions, and the linearity could be used to detect the concentration of acid. The experiments further manifested that (i) the RSD values of intra-day and inter-day runs were less than 1.59 and 3.76%, respectively, indicating similar precision and stability in capillary electrophoresis or HPLC; (ii) the indicators with different pK(a) values had no obvious effect on EABT, distinguishing strong influence on the judgment of equivalence-point titration in the classic one; and (iii) the constant equivalence-point titration always existed in the EABT, rather than the classic volumetric analysis. Additionally, the EABT could be put to good use for the determination of actual acid concentrations. The experimental results achieved herein showed a new general guidance for the development of classic volumetric analysis and element (e.g. nitrogen) content analysis in protein chemistry. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. TFOS DEWS II pathophysiology report.

    Science.gov (United States)

    Bron, Anthony J; de Paiva, Cintia S; Chauhan, Sunil K; Bonini, Stefano; Gabison, Eric E; Jain, Sandeep; Knop, Erich; Markoulli, Maria; Ogawa, Yoko; Perez, Victor; Uchino, Yuichi; Yokoi, Norihiko; Zoukhri, Driss; Sullivan, David A

    2017-07-01

    The TFOS DEWS II Pathophysiology Subcommittee reviewed the mechanisms involved in the initiation and perpetuation of dry eye disease. Its central mechanism is evaporative water loss leading to hyperosmolar tissue damage. Research in human disease and in animal models has shown that this, either directly or by inducing inflammation, causes a loss of both epithelial and goblet cells. The consequent decrease in surface wettability leads to early tear film breakup and amplifies hyperosmolarity via a Vicious Circle. Pain in dry eye is caused by tear hyperosmolarity, loss of lubrication, inflammatory mediators and neurosensory factors, while visual symptoms arise from tear and ocular surface irregularity. Increased friction targets damage to the lids and ocular surface, resulting in characteristic punctate epithelial keratitis, superior limbic keratoconjunctivitis, filamentary keratitis, lid parallel conjunctival folds, and lid wiper epitheliopathy. Hybrid dry eye disease, with features of both aqueous deficiency and increased evaporation, is common and efforts should be made to determine the relative contribution of each form to the total picture. To this end, practical methods are needed to measure tear evaporation in the clinic, and similarly, methods are needed to measure osmolarity at the tissue level across the ocular surface, to better determine the severity of dry eye. Areas for future research include the role of genetic mechanisms in non-Sjögren syndrome dry eye, the targeting of the terminal duct in meibomian gland disease and the influence of gaze dynamics and the closed eye state on tear stability and ocular surface inflammation. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Characterization of Bacterial and Fungal Community Dynamics by High-Throughput Sequencing (HTS Metabarcoding during Flax Dew-Retting

    Directory of Open Access Journals (Sweden)

    Christophe Djemiel

    2017-10-01

    Full Text Available Flax dew-retting is a key step in the industrial extraction of fibers from flax stems and is dependent upon the production of a battery of hydrolytic enzymes produced by micro-organisms during this process. To explore the diversity and dynamics of bacterial and fungal communities involved in this process we applied a high-throughput sequencing (HTS DNA metabarcoding approach (16S rRNA/ITS region, Illumina Miseq on plant and soil samples obtained over a period of 7 weeks in July and August 2014. Twenty-three bacterial and six fungal phyla were identified in soil samples and 11 bacterial and four fungal phyla in plant samples. Dominant phyla were Proteobacteria, Bacteroidetes, Actinobacteria, and Firmicutes (bacteria and Ascomycota, Basidiomycota, and Zygomycota (fungi all of which have been previously associated with flax dew-retting except for Bacteroidetes and Basidiomycota that were identified for the first time. Rare phyla also identified for the first time in this process included Acidobacteria, CKC4, Chlorobi, Fibrobacteres, Gemmatimonadetes, Nitrospirae and TM6 (bacteria, and Chytridiomycota (fungi. No differences in microbial communities and colonization dynamics were observed between early and standard flax harvests. In contrast, the common agricultural practice of swath turning affects both bacterial and fungal community membership and structure in straw samples and may contribute to a more uniform retting. Prediction of community function using PICRUSt indicated the presence of a large collection of potential bacterial enzymes capable of hydrolyzing backbones and side-chains of cell wall polysaccharides. Assignment of functional guild (functional group using FUNGuild software highlighted a change from parasitic to saprophytic trophic modes in fungi during retting. This work provides the first exhaustive description of the microbial communities involved in flax dew-retting and will provide a valuable benchmark in future studies aiming

  12. A systematic approach to find the best road map for enhancement of a power plant with dew point inlet air pre-cooling of the air compressor

    International Nuclear Information System (INIS)

    Sohani, Ali; Farasati, Yashar; Sayyaadi, Hoseyn

    2017-01-01

    Highlights: • Dew-point cooler was proposed in order to enhance a power plant. • A systematic method to find the best road map was offered. • Investigation was done considering four optimization scenarios and different investment plans. • Payback period of the final plan was 2.67 years. • Annual net power and steam generation’s capability were improved 6.02% and 8.92%. - Abstract: Dimensional characteristics and operating parameters of the optimized Maisotsenko indirect evaporative cooler for pre-cooling of the compressor’s inlet air and consequently enhancement of the gas-turbine power generation system as well as the best investment strategy for it were found for an in-operation combined cycle power plant through a systematic approach. Four optimization scenarios were proposed considering different combinations of annual average of net power of the gas-turbine power generation system, payback period time and enthalpy difference of exhaust gases compared to the reference state of each gas-turbine power generation system as objective functions. In each scenario, optimization was conducted for different possible percentages of investment allocated to the research and development of the project. After that, analytical hierarchy process was used to find the best percentage of investment allocated to the research and development of the project of each scenario and the final selected one. Having introduced the approach, it was implemented for Montazer-Ghaem combined cycle power plant in Iran. The results showed for that case study, the analytical hierarchy process selected an optimization scenario in which the annual average of the net power and the enthalpy difference of the exhaust gases compared to the reference state were the objective functions and 15% of the total profit of the gas-turbine power generation system sold electricity was dedicated to the improvement project. This optimization had the payback period time of 2.67 years and it also improved

  13. Optimization of Palmitic Acid Composition in Crude Oleic Acid to Provide Specifications of Titer and Cloud Point of Distillate Oleic Acid using a Flash Distiller

    Directory of Open Access Journals (Sweden)

    Muhammad Yusuf Ritonga

    2010-11-01

    Full Text Available Titer and cloud point of Distilled Oleic Acid is higher than is the standard on feed composition palmitic acid (C15H31COOH or C16 11.2 %. Feed composition C16, top temperature precut and bottom main distiller column were optimized to produce DOA. A factorial design with 3 independent variables, 3 X 2 X 3, repeated twice as much, is applied to observe effects of feed composition C16 to quality parameters. In the optimum C16, feed composition at 5.20 % produced DOA with titer 6.8 oC, cloud point 5.0 oC (inside its specification.

  14. Humidity measurement using alpha-ray and beta-ray

    International Nuclear Information System (INIS)

    Matsumoto, Shigeaki; Kobayashi, Hisanobu

    1981-01-01

    Two new hygrometers using radioisotopes were proposed, and the results of tests are described. The one is a dew-point hygrometer utilizing the backscattering phenomena of beta-ray by dew, and the other is a hygrometer by measuring the variation of ionization current by alpha ray due to humidity. The backscattering of beta-ray depends on the atomic number of scatters and the energy of beta-ray. Therefore, the backscattering from dew on a gold plate is different from that from the gold itself. The temperature dependence of the backscattering intensity was measured with a GM counter. Decrease of the intensity was seen at the dew point. A control circuit was designed to measure the dew point automatically. The error of the measurement was within 1 degree C. An alpha-ray ionization hygrometer was constructed. The dependence of ionization current on humidity was measured with an operational amplifier. The resolution of humidity measurement was within 5 percent. (Kato, T.)

  15. Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling – Paving the path toward sustainable cooling of buildings

    International Nuclear Information System (INIS)

    Zhan, Changhong; Duan, Zhiyin; Zhao, Xudong; Smith, Stefan; Jin, Hong; Riffat, Saffa

    2011-01-01

    This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research

  16. Simple Approaches to Minimally-Instrumented, Microfluidic-Based Point-of-Care Nucleic Acid Amplification Tests

    Science.gov (United States)

    Mauk, Michael G.; Song, Jinzhao; Liu, Changchun; Bau, Haim H.

    2018-01-01

    Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges (‘chips’) that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed. PMID:29495424

  17. Simple Approaches to Minimally-Instrumented, Microfluidic-Based Point-of-Care Nucleic Acid Amplification Tests

    Directory of Open Access Journals (Sweden)

    Michael G. Mauk

    2018-02-01

    Full Text Available Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC tests for resource-limited settings. Microfluidic cartridges (‘chips’ that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets is demonstrated. Low-cost detection and added functionality (data analysis, control, communication can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed.

  18. Projection of Korean Probable Maximum Precipitation under Future Climate Change Scenarios

    Directory of Open Access Journals (Sweden)

    Okjeong Lee

    2016-01-01

    Full Text Available According to the IPCC Fifth Assessment Report, air temperature and humidity of the future are expected to gradually increase over the current. In this study, future PMPs are estimated by using future dew point temperature projection data which are obtained from RCM data provided by the Korea Meteorological Administration. First, bias included in future dew point temperature projection data which is provided on a daily basis is corrected through a quantile-mapping method. Next, using a scale-invariance technique, 12-hour duration 100-year return period dew point temperatures which are essential input data for PMPs estimation are estimated from bias-corrected future dew point temperature data. After estimating future PMPs, it can be shown that PMPs in all future climate change scenarios (AR5 RCP2.6, RCP 4.5, RCP 6.0, and RCP 8.5 are very likely to increase.

  19. TFOS DEWS II Definition and Classification Report.

    Science.gov (United States)

    Craig, Jennifer P; Nichols, Kelly K; Akpek, Esen K; Caffery, Barbara; Dua, Harminder S; Joo, Choun-Ki; Liu, Zuguo; Nelson, J Daniel; Nichols, Jason J; Tsubota, Kazuo; Stapleton, Fiona

    2017-07-01

    The goals of the TFOS DEWS II Definition and Classification Subcommittee were to create an evidence-based definition and a contemporary classification system for dry eye disease (DED). The new definition recognizes the multifactorial nature of dry eye as a disease where loss of homeostasis of the tear film is the central pathophysiological concept. Ocular symptoms, as a broader term that encompasses reports of discomfort or visual disturbance, feature in the definition and the key etiologies of tear film instability, hyperosmolarity, and ocular surface inflammation and damage were determined to be important for inclusion in the definition. In the light of new data, neurosensory abnormalities were also included in the definition for the first time. In the classification of DED, recent evidence supports a scheme based on the pathophysiology where aqueous deficient and evaporative dry eye exist as a continuum, such that elements of each are considered in diagnosis and management. Central to the scheme is a positive diagnosis of DED with signs and symptoms, and this is directed towards management to restore homeostasis. The scheme also allows consideration of various related manifestations, such as non-obvious disease involving ocular surface signs without related symptoms, including neurotrophic conditions where dysfunctional sensation exists, and cases where symptoms exist without demonstrable ocular surface signs, including neuropathic pain. This approach is not intended to override clinical assessment and judgment but should prove helpful in guiding clinical management and research. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Calibration of moisture monitors

    International Nuclear Information System (INIS)

    Gutierrez, R.L.

    1979-02-01

    A method for calibrating an aluminum oxide hygrometer against an optical chilled mirror dew-point hygrometer has been established. A theoretical cross-point line of dew points from both hygrometers and a maximum moisture content of 10 ppM/sub v/ are used to define an area for calibrating the sensor probes of the aluminum oxide hygrometer

  1. Extreme precipitation response to climate perturbations in an atmospheric mesoscale model

    NARCIS (Netherlands)

    Attema, J.J.; Loriaux, J.M.; Lenderink, G.

    2014-01-01

    Observations of extreme (sub) hourly precipitation at midlatitudes show a large dependency on the dew point temperature often close to 14% per degree—2 times the dependency of the specific humidity on dew point temperature which is given by the Clausius–Clapeyron (CC) relation. By simulating a

  2. Delivery of State-Provided Predictive Analytics to Schools: Wisconsin's DEWS and the Proposed EWIMS Dashboard. WCER Working Paper No. 2016-3

    Science.gov (United States)

    Clune, Bill; Knowles, Jared

    2016-01-01

    Since 2012, the Wisconsin Department of Public Instruction (DPI) has maintained a statewide predictive analytics system providing schools with an early warning in middle grades of students at risk for not completing high school. DPI is considering extending and enhancing this system, known as the Dropout Early Warning System (DEWS). The proposed…

  3. Extended Gate Field-Effect Transistor Biosensors for Point-Of-Care Testing of Uric Acid.

    Science.gov (United States)

    Guan, Weihua; Reed, Mark A

    2017-01-01

    An enzyme-free redox potential sensor using off-chip extended-gate field effect transistor (EGFET) with a ferrocenyl-alkanethiol modified gold electrode has been used to quantify uric acid concentration in human serum and urine. Hexacyanoferrate (II) and (III) ions are used as redox reagent. The potentiometric sensor measures the interface potential on the ferrocene immobilized gold electrode, which is modulated by the redox reaction between uric acid and hexacyanoferrate ions. The device shows a near Nernstian response to uric acid and is highly specific to uric acid in human serum and urine. The interference that comes from glucose, bilirubin, ascorbic acid, and hemoglobin is negligible in the normal concentration range of these interferents. The sensor also exhibits excellent long term reliability and is regenerative. This extended gate field effect transistor based sensor is promising for point-of-care detection of uric acid due to the small size, low cost, and low sample volume consumption.

  4. Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests

    International Nuclear Information System (INIS)

    Nho, Ki Man; Kim, Wang Bae

    1998-01-01

    The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO 2 gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for dew point rate of rise of Wolsung Unit 2. It was found that the response of the dew point depends on the moisture injection rate, CO 2 gas flow rate and the leak location. The test showed that Candu 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS CO 2 flow rate is approximated. (author)

  5. Nucleic-acid testing, new platforms and nanotechnology for point-of-decision diagnosis of animal pathogens.

    Science.gov (United States)

    Teles, Fernando; Fonseca, Luís

    2015-01-01

    Accurate disease diagnosis in animals is crucial for animal well-being but also for preventing zoonosis transmission to humans. In particular, livestock diseases may constitute severe threats to humans due to the particularly high physical contact and exposure and, also, be the cause of important economic losses, even in non-endemic countries, where they often arise in the form of rapid and devastating epidemics. Rapid diagnostic tests have been used for a long time in field situations, particularly during outbreaks. However, they mostly rely on serological approaches, which may confirm the exposure to a particular pathogen but may be inappropriate for point-of-decision (point-of-care) settings when emergency responses supported on early and accurate diagnosis are required. Moreover, they often exhibit modest sensitivity and hence significantly depend on later result confirmation in central or reference laboratories. The impressive advances observed in recent years in materials sciences and in nanotechnology, as well as in nucleic-acid synthesis and engineering, have led to an outburst of new in-the-bench and prototype tests for nucleic-acid testing towards point-of-care diagnosis of genetic and infectious diseases. Manufacturing, commercial, regulatory, and technical nature issues for field applicability more likely have hindered their wider entrance into veterinary medicine and practice than have fundamental science gaps. This chapter begins by outlining the current situation, requirements, difficulties, and perspectives of point-of-care tests for diagnosing diseases of veterinary interest. Nucleic-acid testing, particularly for the point of care, is addressed subsequently. A range of valuable signal transduction mechanisms commonly employed in proof-of-concept schemes and techniques born on the analytical chemistry laboratories are also described. As the essential core of this chapter, sections dedicated to the principles and applications of microfluidics, lab

  6. Flooding During Drought: Learning from Stakeholder Engagement & Partner Coordination in the California-Nevada Drought Early Warning System (DEWS)

    Science.gov (United States)

    Sheffield, A. M.

    2017-12-01

    After more than 5 years of drought, extreme precipitation brought drought relief in California and Nevada and presents an opportunity to reflect upon lessons learned while planning for the future. NOAA's National Integrated Drought Information System (NIDIS) California-Nevada Drought Early Warning System (DEWS) in June 2017 convened a regional coordination workshop to provide a forum to discuss and build upon past drought efforts in the region and increase coordination, collaboration and information sharing across the region as a whole. Participants included federal, tribal, state, academic, and local partners who provided a post-mortem on the recent drought and impacts as well as recent innovations in drought monitoring, forecasts, and decision support tools in response to the historic drought. This presentation will highlight lessons learned from stakeholder outreach and engagement around flooding during drought, and pathways for moving forward coordination and collaboration in the region. Additional focus will be on the potential opportunities from examining California decision making calendars from this drought. Identified gaps and challenges will also be shared, such as the need to connect observations with social impacts, capacity building around available tools and resources, and future drought monitoring needs. Drought will continue to impact California and Nevada, and the CA-NV DEWS works to make climate and drought science readily available, easily understandable and usable for decision makers; and to improve the capacity of stakeholders to better monitor, forecast, plan for and cope with the impacts of drought.

  7. Desiccant Dewpoint Cooling System Independent of External Water Sources

    DEFF Research Database (Denmark)

    Bellemo, Lorenzo; Elmegaard, Brian; Markussen, Wiebke B.

    2015-01-01

    the air that regenerates the desiccant dehumidifier, and using it for running the evaporative coolers in the system. A closed regeneration circuit is used for maximizing the amount of condensed water. This solution is applied to a system with a desiccant wheel dehumidifier and a dew point cooler, termed...... desiccant dew-point cooling system, for demonstrating its function and applicability. Simulations are carried out for varying outdoor conditions under constant supply conditions. The results show that the system is independent of external water supply for the majority of simulated conditions. In comparison...... to the desiccant dew-point system without water recovery, the required regeneration temperature increases and the system thermal efficiency decreases....

  8. Isoelectric Point, Electric Charge, and Nomenclature of the Acid-Base Residues of Proteins

    Science.gov (United States)

    Maldonado, Andres A.; Ribeiro, Joao M.; Sillero, Antonio

    2010-01-01

    The main object of this work is to present the pedagogical usefulness of the theoretical methods, developed in this laboratory, for the determination of the isoelectric point (pI) and the net electric charge of proteins together with some comments on the naming of the acid-base residues of proteins. (Contains 8 figures and 4 tables.)

  9. Optimization of Palmitic Acid Composition in Crude Oleic Acid to Provide Specifications of Titer and Cloud Point of Distillate Oleic Acid using a Flash Distiller

    OpenAIRE

    Muhammad Yusuf Ritonga

    2010-01-01

    Titer and cloud point Distilled Oleic Acid’s higher than standard on feed composition palmitic acid (C15H31COOH) or C16 11.2 %. Feed composition C16, top temperature precut and bottom main distiller column were optimized to produce DOA. A factorial design 3 independent variables 3 X 2 X 3, twice repeating’s applied to observe effects of feed composition C16 to quality parameters. On the optimum C16 feed composition at 5.20 % was produced DOA with titer 6.8 oC, cloud point 5.0 oC (inside it...

  10. Investigating the significance of zero-point motion in small molecular clusters of sulphuric acid and water

    International Nuclear Information System (INIS)

    Stinson, Jake L.; Ford, Ian J.; Kathmann, Shawn M.

    2014-01-01

    The nucleation of particles from trace gases in the atmosphere is an important source of cloud condensation nuclei, and these are vital for the formation of clouds in view of the high supersaturations required for homogeneous water droplet nucleation. The methods of quantum chemistry have increasingly been employed to model nucleation due to their high accuracy and efficiency in calculating configurational energies; and nucleation rates can be obtained from the associated free energies of particle formation. However, even in such advanced approaches, it is typically assumed that the nuclei have a classical nature, which is questionable for some systems. The importance of zero-point motion (also known as quantum nuclear dynamics) in modelling small clusters of sulphuric acid and water is tested here using the path integral molecular dynamics method at the density functional level of theory. The general effect of zero-point motion is to distort the mean structure slightly, and to promote the extent of proton transfer with respect to classical behaviour. In a particular configuration of one sulphuric acid molecule with three waters, the range of positions explored by a proton between a sulphuric acid and a water molecule at 300 K (a broad range in contrast to the confinement suggested by geometry optimisation at 0 K) is clearly affected by the inclusion of zero point motion, and similar effects are observed for other configurations

  11. Dew drops on spider web appearance: a newly named pattern of IgG4 deposition in pemphigus with direct immunofluorescence

    Directory of Open Access Journals (Sweden)

    Marian Dmochowski

    2017-08-01

    Full Text Available Novel appearances in cutaneous pathology as well as mucocutaneous clinical signs are being described which indicate that this is still an attractive area for exploration. The H + E histology terms of “decorated tomb stoning” and “undecorated tomb stoning”, advocated by some pathologists, are misleading and as such should be avoided. Here, an appearance of IgG4 pemphigus deposits examined cost-effectively with direct immunofluorescence and suggested to be called “dew drops on spider web” is depicted in depth.

  12. Measurement of total acid number (TAN) and TAN boiling point distribution in petroleum products by electrospray ionization mass spectrometry.

    Science.gov (United States)

    Qian, Kuangnan; Edwards, Kathleen E; Dechert, Gary J; Jaffe, Stephen B; Green, Larry A; Olmstead, William N

    2008-02-01

    We report a new method for rapid measurement of total acid number (TAN) and TAN boiling point (BP) distribution for petroleum crude and products. The technology is based on negative ion electrospray ionization mass spectrometry (ESI-MS) for selective ionization of petroleum acid and quantification of acid structures and molecular weight distributions. A chip-based nanoelectrospray system enables microscale (boiling point distributions of TAN values can be calculated from the composition. The rapid measurement of TAN BP distributions by ESI is demonstrated for a series of high-TAN crudes and distillation cuts. TAN values determined by the technique agree well with those by the titration method. The distributed properties compare favorably with those measured by distillation and measurement of TAN of corresponding cuts.

  13. Evaluation of a clay-based acidic bedding conditioner for dairy cattle bedding.

    Science.gov (United States)

    Proietto, R L; Hinckley, L S; Fox, L K; Andrew, S M

    2013-02-01

    This study investigated the effects of a clay-based acidic bedding conditioner on sawdust bedding pH, dry matter (DM), environmental pathogen counts, and environmental bacterial counts on teat ends of lactating dairy cows. Sixteen lactating Holstein cows were paired based on parity, days in milk, milk yield, and milk somatic cell count, and were negative for the presence of an intramammary pathogen. Within each pair, cows were randomly assigned to 1 of 2 treatments with 3-wk periods in a crossover design. Treatment groups consisted of 9 freestalls per group bedded with either untreated sawdust or sawdust with a clay-based acidic bedding conditioner, added at 3- to 4-d intervals over each 21-d period. Bedding and teat ends were aseptically sampled on d 0, 1, 2, 7, 14, and 21 for determination of environmental bacterial counts. At the same time points, bedding was sampled for DM and pH determination. The bacteria identified in the bedding material were total gram-negative bacteria, Streptococcus spp., and coliform bacteria. The bacteria identified on the teat ends were Streptococcus spp., coliform bacteria, and Klebsiella spp. Teat end score, milk somatic cell count, and intramammary pathogen presence were measured weekly. Bedding and teat cleanliness, environmental high and low temperatures, and dew point data were collected daily. The bedding conditioner reduced the pH, but not the DM, of the sawdust bedding compared with untreated sawdust. Overall environmental bacterial counts in bedding were lower for treated sawdust. Total bacterial counts in bedding and on teat ends increased with time over both periods. Compared with untreated sawdust, the treated bedding had lower counts of total gram-negative bacteria and streptococci, but not coliform counts. Teat end bacterial counts were lower for cows bedded on treated sawdust for streptococci, coliforms, and Klebsiella spp. compared with cows bedded on untreated sawdust. The clay-based acidic bedding conditioner

  14. A study on the effects of system pressure on heat and mass transfer rates of an air cooler

    International Nuclear Information System (INIS)

    Jung, Hyung Ho

    2002-01-01

    In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements

  15. Modeling of atmospheric corrosion environments and its application to constant dew-point corrosion test; Yagai taiki fushoku kankyo no modeling to sore ni motozuku teirotengata saikuru fushoku shikenho no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Muto, I. [Nippon Steel Corp., Tokyo (Japan)] Sugimoto, K. [Tohoku Univ., Sendai (Japan)

    1998-08-15

    Recently, stainless steel is increasing its demand for corrosion resistant building materials. Then, as it is necessary to develop and accelerating testing method capable of accurately estimating weatherability at sea side area, such testing method has no been developed yet because of difficulty to quantify corrosive environment relating to atmospheric corrosion phenomenon. As air temperature and relative humidity in outdoor change in complex, specific temperature and relative humidity cannot be used for their representative values. And, construction of corrosive factors such as sea salt particles, and so on are also much different at each area. However, at coastal area, a dew water dissolving the sea salt particles, so called droplets of chlorides aqueous solution is formed onto material surface. Then, in this study, on a base of drying and humidity absorption behavior and daily change behavior of temperature and humidity in outdoor, modeling of atmospheric corrosion environment was tried. An accelerating testing method according to this modeling was developed, long-term weathering test was compared with the corrosion behavior of the same steel, and validity of a new accelerating testing method was evaluated. 22 refs., 12 figs., 2 tabs.

  16. Control of the dew point for refreshing ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Abrach, R.; Nitz, T.

    1996-03-01

    The functioning of a refreshing ceiling, delivered in water, needs a global regulation which must take in consideration, the local, the building and its environment. Then efficiency and energy and investments economy are optimized. 11 figs., 3 tabs.

  17. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. II. Citric, tartaric, undecylenic acids

    Energy Technology Data Exchange (ETDEWEB)

    Harangozo, M.; Jombik, J.; Schiller, P. (Komenskeho Univ., Bratislava (Czechoslovakia). Farmaceuticka Fakulta); Toelgyessy, J. (Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia). Chemickotechnologicka Fakulta)

    1981-01-01

    A method for the determination of citric, tartaric and undecylenic acids based on radiometric titration with 0.1 or 0.05 mole.l/sup -1/ NaOH was developed. As an indicator of the end point, radioactive kryptonate of glass was used. Experimental technique, results of determinations as well as other possible applications of the radioactive kryptonate of glass for end point determination in alkalimetric analyses of officinal pharmaceuticals are discussed.

  18. Removing well bore liquid blockage by gas injection

    International Nuclear Information System (INIS)

    Ahmed, Tarek

    2000-01-01

    Gas condensate reservoirs have long presented production problems when the pressure around the well bore drops below the dew point pressure. The formation of the condensate around the well bore can be thought of as an additional 'skin' that causes a reduction in the gas flow rates. Many processes have been used successfully to prevent or reduce the formation of liquids within the entire reservoir, such as pressure maintenance schemes and gas cycling processes. The pressure maintenance scheme is designed to keep the reservoir pressure at or above the dew point pressure while the gas cycling process is intended to reduce the liquid dropout by vaporization.Often times the pressure in the near-well bore region of the reservoir falls below the dew point pressure, while the pressure in the reservoir remains higher than the dew point pressure. As the near-well bore pressure drops below the dew point pressure, retrograde condensation occurs leading to the formation and then the mobilization of the condensate phase towards the producing wells. The liquid phase accumulates in the near Well bore region, forming a ring, which progressively reduces the gas deliverability. This study is designed to provide an insight into the mechanism of gas injection process in reducing gas-well productivity losses due to condensate blocking in the near well bore region. The study also evaluates the effectiveness of lean gas, N 2 , and CO 2 Huff 'n' Puff injection technique in removing the liquid dropout accumulation in and around the well bore. Results of the study show the importance of selecting the optimum injection volume and pressure. (author)

  19. Measurements of dry-deposition parameters for the California acid-deposition monitoring program. Final report

    International Nuclear Information System (INIS)

    Watson, J.G.; Chow, J.C.; Egami, R.T.; Bowen, J.L.; Frazier, C.A.

    1991-06-01

    The State of California monitors the concentrations of acidic gases and particles at 10 sites throughout the state. Seven sites represent urban areas (South Coast Air Basin - three sites, San Francisco Bay Area, Bakersfield, Santa Barbara, and Sacramento) and three represent forested areas (Sequoia National Park, Yosemite National Park, and Gasquet). Several sites are collocated with monitoring instruments for other air quality and forest response networks. Continuous monitors for the dry deposition network collect hourly average values for ozone, wind speed, wind direction, atmospheric stability, temperature, dew point, time of wetness, and solar radiation. A newly-designed gas/particle sampler collects daytime (6 a.m. to 6 p.m.) and nighttime (6 p.m. to 6 a.m.) samples every sixth day for sulfur dioxide, ammonia, nitrogen dioxide, and nitric acid. Particles are collected on the same day/night schedule in PM(10) and PM(2.5) size ranges, and are analyzed for mass, sulfate, nitrate, chloride, ammonium, sodium, magnesium, potassium, and calcium ions. The sampling schedule follows the regulatory schedule adopted by the EPA and ARB for suspended particulate matter. Wet deposition data are collected at or nearby the dry deposition stations. The first year of the monitoring program included installation of the network, training of technicians, acquisition and validation of data, and transfer of the sampling and analysis technology to Air Resources Board operating divisions. Data have been validated and stored for the period May, 1988 through September, 1989

  20. Theory, Electro-Optical Design, Testing, and Calibration of a Prototype Atmospheric Supersaturation, Humidity, and Temperature Sensor.

    Science.gov (United States)

    1982-07-15

    Voltage versus Aspirated Dew Point 94 Hygrometer Reading in Degrees Celsius (10 Second Averages) Fig. (7.5)(b) Scatter Diagram - NCAR Lyman-Alpha...Hygrometer Output Voltage versus Aspirated Dew Point Hygrometer Reading in Degrees Celsius (10 Second Averages) Fig. (7.6) Ophir Air Temperature...goal thus translates to an absolute humidity accuracy of 1% of reading or better over a dynamic r-dnj(! ,(f i(jul. 4 uder. of magnitude. 29 - ITI VAP

  1. Study and realization of a new humid air generator; towards the definition of a dew temperature reference; Etude et realisation d'un nouveau generateur d'air humide; vers la definition d'une reference en temperature de rosee

    Energy Technology Data Exchange (ETDEWEB)

    Blanquart, B.

    2001-03-01

    The air humidity is an important parameter for several biological and physico-chemical processes. The aim of this thesis is the direct determination of the dew temperature without any link with the gravimetric reference. This document presents the realization and adjusting of a new humid air generator for the -80 deg. C to +15 deg. C range and the uncertainty linked with the dew temperature of the humid air generated. The first chapter recalls the definitions of humid air related data and the principles of the apparatuses used for the measurement of air humidity. The second chapter deals with temperature measurements while chapter 3 describes the new humid air generator built around an 'ideal' cell based on the theoretical definition of the dew temperature. Technical constraints due to temperature measurement and to hygrometers calibration are progressively integrated and introduced and lead to the practical realization of the device. Differences between the ideal cell and the prototype are estimated using a theoretical approach of mass and heat exchanges coupled with experimental results obtained with a previous prototype. Chapter 4 presents a first status of the device uncertainties with some possibilities of reduction of these uncertainties. (J.S.)

  2. The Phase Envelope of Multicomponent Mixtures in the Presence of a Capillary Pressure Difference

    DEFF Research Database (Denmark)

    Sandoval Lemus, Diego Rolando; Yan, Wei; Michelsen, Michael Locht

    2016-01-01

    for test mixtures with wide ranges of compositions at different capillary radii and vapor fractions. The calculation results show that the phase envelope changes everywhere except at the critical point. The bubble point and the lower branch of the dew point show a decrease in the saturation pressure......, whereas the upper branch of the dew point shows an increase. The cricondentherm is shifted to a higher temperature. We also presented a mathematical analysis of the phase envelope shift due to capillary pressure based on linear approximations. The resulting linear approximation equations can predict...... the magnitude of shift, and the approximation is close for the change in the bubble point pressure....

  3. Ecosystem-scale compensation points of formic and acetic acid in the central Amazon

    Directory of Open Access Journals (Sweden)

    K. Jardine

    2011-12-01

    Full Text Available Organic acids, central to terrestrial carbon metabolism and atmospheric photochemistry, are ubiquitous in the troposphere in the gas, particle, and aqueous phases. As the dominant organic acids in the atmosphere, formic acid (FA, HCOOH and acetic acid (AA, CH3COOH control precipitation acidity in remote regions and may represent a critical link between the terrestrial carbon and water cycles by acting as key intermediates in plant carbon and energy metabolism and aerosol-cloud-precipitation interactions. However, our understanding of the exchange of these acids between terrestrial ecosystems and the atmosphere is limited by a lack of field observations, the existence of biogenic and anthropogenic primary and secondary sources whose relative importance is unclear, and the fact that vegetation can act as both a source and a sink. Here, we first present data obtained from the tropical rainforest mesocosm at Biosphere 2 which isolates primary vegetation sources. Strong light and temperature dependent emissions enriched in FA relative to AA were simultaneously observed from individual branches (FA/AA = 3.0 ± 0.7 and mesocosm ambient air (FA/AA = 1.4 ± 0.3. We also present long-term observations of vertical concentration gradients of FA and AA within and above a primary rainforest canopy in the central Amazon during the 2010 dry and 2011 wet seasons. We observed a seasonal switch from net ecosystem-scale deposition during the dry season to net emissions during the wet season. This switch was associated with reduced ambient concentrations in the wet season (FA < 1.3 nmol mol−1, AA < 2.0 nmol mol−1 relative to the dry season (FA up to 3.3 nmol mol−1, AA up to 6.0 nmol mol−1, and a simultaneous increase in the FA/AA ambient concentration ratios from 0.3–0.8 in the dry season to 1.0–2.1 in the wet season. These observations are consistent with a switch between a biomass burning dominated

  4. The free fractions of circulating docosahexaenoic acid and eicosapentenoic acid as optimal end-point of measure in bioavailability studies on n-3 fatty acids.

    Science.gov (United States)

    Scarsi, Claudia; Levesque, Ann; Lisi, Lucia; Navarra, Pierluigi

    2015-05-01

    The high complexity of n-3 fatty acids absorption process, along with the huge amount of endogenous fraction, makes bioavailability studies with these agents very challenging and deserving special consideration. In this paper we report the results of a bioequivalence study between a new formulation of EPA+DHA ethyl esters developed by IBSA Institut Biochimique and reference medicinal product present on the Italian market. Bioequivalence was demonstrated according to the criteria established by the EMA Guideline on the Investigation of Bioequivalence. We found that the free fractions represent a better and more sensitive end-point for bioequivalence investigations on n-3 fatty acids, since: (i) the overall and intra-subject variability of PK parameters was markedly lower compared to the same variability calculated on the total DHA and EPA fractions; (ii) the absorption process was completed within 4h, and the whole PK profile could be drawn within 12-15 h from drug administration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Tritium concentration monitor

    International Nuclear Information System (INIS)

    Shono, Kosuke.

    1991-01-01

    A device for measuring the concentration of tritium in gaseous wastes in a power plant and a nuclear fuel reprocessing plant is reduced in the size and improved in performance. The device of the present invention pressurizes a sampling gas and cools it to a dew point. Water content in the sampling gas cooled to the dew point is condensated and recovered to a fine tube-like water content recovering container. The concentration of the recovered condensates is measured by a tritium density analyzer. With such procedures, since the specimen is pressurized, the dew point can be elevated. Accordingly, the size of the cooling device can be decreased, enabling to contribute to the reduction of the size of the entire device. Further, since the water content recovering device is formed as a fine tube, the area of contact between the specimen gas and the liquid condensated water can be reduced. Accordingly, evaporation of the liquid condensates can be prevented. (I.S.)

  6. Hygromorphic Scales for Use in Water from Morning Dew and Elementary Model of Hydrogel Expansion Properties

    Science.gov (United States)

    Margolis, Nate

    Secure access to water is a growing problem in the world today. Millions of people do not have contact with fresh or clean water for drinking. Consuming dirty water leads to many illnesses and deaths every year. When water is scarce people are less likely to follow basic hygiene which also adds to the problem of sickness from water. Currently most of the population gets their water from run-off such as rivers, lakes and other fresh water bodies. Aquafers can also provide water, however, once they do not replenish themselves so once they are empty they will no longer provide a fresh water source. This is a serious problem because the population has grown to 7 billion people and only 2% of the world's water is fresh water. Of this, most the fresh water is locked in the polar ice caps. This leaves only .77% of the available fresh water accessible for human use. While wealthy countries may not feel this burden due to their infrastructure. Impoverish countries will feel the full burden of a lack of water. This has led to a growing number of water conflicts over the years some of which have resulted in human deaths. There are several ways that people can collect water from the atmosphere such as collecting rain water or using a solar still to evaporate water out of an undrinkable source. In parts of the world where fog is prevalent, meshes have been used to collect the moisture from the air. However, these systems only work where the environment allows for it. In some places in the world, the only amount of water may come from morning dew. Certain places receive more water from morning dew than they do from annual precipitation. By studying nature, a novel water collection device was developed, tested and modeled. The model is compared to the test data to see the ways in which the device can be optimized. This could be used to help alleviate the growing problems of water shortages in specific parts of the world. The model and device design shows promising data but still

  7. Dew Point Evaporative Comfort Cooling: Report and Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Dean, J.; Herrmann, L.; Kozubal, E.; Geiger, J.; Eastment, M.; Slayzak, S.

    2012-11-01

    The project objective was to demonstrate the capabilities of the high-performance multi-staged IEC technology and its ability to enhance energy efficiency and interior comfort in dry climates, while substantially reducing electric-peak demand. The project was designed to test 24 cooling units in five commercial building types at Fort Carson Army Base in Colorado Springs, Colorado.

  8. Thermodynamic and kinetic aspects on the selective surface oxidation of binary, ternary and quarternary model alloys

    International Nuclear Information System (INIS)

    Swaminathan, Srinivasan; Spiegel, Michael

    2007-01-01

    Segregation and selective oxidation phenomena of minor alloying elements during annealing of steel sheets lead to the formation of bare spots after hot dip galvanizing. In order to understand the influence of common alloying elements on the surface chemistry after annealing, model alloys of binary (Fe-2Si, Fe-2Mn and Fe-0.8Cr), ternary (Fe-2Mn-2Si, Fe-2Mn-0.8Cr and Fe-2Si-0.8Cr) and quarternary (Fe-2Mn-2Si-0.8Cr) systems were investigated. The specimens were annealed for 60 s at 820 deg. C in N 2 -5% H 2 gas atmospheres with different dew points -80 and -40 deg. C, respectively. Surface chemistry of the annealed specimens was obtained by using X-ray photoelectron spectroscopy (XPS). The field emission scanning electron microscopy (FE-SEM) was used to view surface morphology. At low dew point -80 deg. C, apart from the thermodynamical calculations such as solubility product of oxides and their critical solute concentrations, kinetics play a decisive role on the selective oxidation, i.e. oxygen competition. As expected, the amount of external selective oxidation of alloying elements are well pronounced at higher dew point -40 deg. C. An attempt has been made to explain the dominant process of Si and Mn on Cr-oxidation and segregation. It is observed that annealing of quarternary system at higher dew point shifts the Cr-oxidation from external to internal

  9. Extreme precipitation response to climate perturbations in an atmospheric mesoscale model

    International Nuclear Information System (INIS)

    Attema, Jisk J; Loriaux, Jessica M; Lenderink, Geert

    2014-01-01

    Observations of extreme (sub-)hourly precipitation at mid-latitudes show a large dependency on the dew point temperature often close to 14% per degree—2 times the dependency of the specific humidity on dew point temperature which is given by the Clausius–Clapeyron (CC) relation. By simulating a selection of 11 cases over the Netherlands characterized by intense showers, we investigate this behavior in the non-hydrostatic weather prediction model Harmonie at a resolution of 2.5 km. These experiments are repeated using perturbations of the atmospheric profiles of temperature and humidity: (i) using an idealized approach with a 2° warmer (colder) atmosphere assuming constant relative humidity, and (ii) using changes in temperature and humidity derived from a long climate change simulation at 2° global warming. All perturbations have a difference in the local dew point temperature compared to the reference of approximately 2°. Differences are considerable between the cases, with dependencies ranging from almost zero to an increase of 18% per degree rise of the dew point temperature. On average however, we find an increase of extreme precipitation intensity of 11% per degree for the idealized perturbation, and 9% per degree for the climate change perturbation. For the most extreme events these dependencies appear to approach a rate of 11–14% per degree, in closer agreement with the observed relation. (paper)

  10. Thermodynamic and kinetic aspects on the selective surface oxidation of binary, ternary and quarternary model alloys

    Energy Technology Data Exchange (ETDEWEB)

    Swaminathan, Srinivasan [High Temperature Reactions Group, Department of Interface Chemistry and Surface Engineering, Max-Planck-Institut fuer Eisenforschung GmbH, Max-Planck-Str. 1, D-40237 Duesseldorf (Germany)]. E-mail: s.swaminathan@mpie.de; Spiegel, Michael [High Temperature Reactions Group, Department of Interface Chemistry and Surface Engineering, Max-Planck-Institut fuer Eisenforschung GmbH, Max-Planck-Str. 1, D-40237 Duesseldorf (Germany)

    2007-03-15

    Segregation and selective oxidation phenomena of minor alloying elements during annealing of steel sheets lead to the formation of bare spots after hot dip galvanizing. In order to understand the influence of common alloying elements on the surface chemistry after annealing, model alloys of binary (Fe-2Si, Fe-2Mn and Fe-0.8Cr), ternary (Fe-2Mn-2Si, Fe-2Mn-0.8Cr and Fe-2Si-0.8Cr) and quarternary (Fe-2Mn-2Si-0.8Cr) systems were investigated. The specimens were annealed for 60 s at 820 deg. C in N{sub 2}-5% H{sub 2} gas atmospheres with different dew points -80 and -40 deg. C, respectively. Surface chemistry of the annealed specimens was obtained by using X-ray photoelectron spectroscopy (XPS). The field emission scanning electron microscopy (FE-SEM) was used to view surface morphology. At low dew point -80 deg. C, apart from the thermodynamical calculations such as solubility product of oxides and their critical solute concentrations, kinetics play a decisive role on the selective oxidation, i.e. oxygen competition. As expected, the amount of external selective oxidation of alloying elements are well pronounced at higher dew point -40 deg. C. An attempt has been made to explain the dominant process of Si and Mn on Cr-oxidation and segregation. It is observed that annealing of quarternary system at higher dew point shifts the Cr-oxidation from external to internal.

  11. Acoustic dew point and bubble point detector for gas condensates and reservoir fluids

    Energy Technology Data Exchange (ETDEWEB)

    Sivaraman, A.; Hu, Y.; Thomas, F. B.; Bennion, D. B.; Jamaluddin, A. K. M. [Hycal Energy Research Labs. Ltd., Calgary, AB (Canada)

    1997-08-01

    Detailed knowledge of bubblepoint and dewpoint pressures at reservoir temperature are crucial for natural gas processing, transportation, metering and utilization. This paper introduces a new acoustic dewpoint and bubblepoint detector that can be applied to a broad range of phase transitions, including very lean gas systems and opaque heavy oils. The system uses two acoustic transducers, one to stimulate and the other to detect normal mode vibrations of reservoir fluids in a small cylindrical resonator. The acoustic spectra are recorded at close intervals throughout the phase envelope, along with temperature, pressure and volume measurements, and the data is processed to obtain the specific condition of phase transition. Results of two systems, a binary mixture and live reservoir fluid, are presented. The detector system is claimed to be capable of operation in an isothermal mode with variable volume, and in a constant volume mode with variable temperatures. Interpretation of results is free of operator subjectivity; they show excellent agreement with results obtained by visual methods and equations of state calculations. 4 refs., 2 tabs., 4 figs.

  12. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. I. Salicylic, acetylosalicylic, benzoic acids

    Energy Technology Data Exchange (ETDEWEB)

    Toelgyessy, J; Dillinger, P [Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia). Chemickotechnologicka Fakulta; Harangozo, M; Jombik, J [Komenskeho Univ., Bratislava (Czechoslovakia). Farmaceuticka Fakulta

    1980-01-01

    A method for the determination of salicylic, acetylsalicylic and benzoic acids in officinal pharmaceutical based on radiometric titration with 0.1 mol.l/sup -1/ NaOH was developed. The end-point was detected with the aid of radioactive glass kryptonate. After the end-point, the excess titrant attacks the glass surface layers and this results in releasing /sup 85/Kr, and consequently, in decreasing the radioactivity of the kryptonate employed. The radioactive kryptonate used as an indicator was prepared by the bombardment of glass with accelerated /sup 85/Kr ions. The developed method is simple, accurate and correct.

  13. Energy Balance, Evapo-transpiration and Dew deposition in the Dead Sea Valley

    Science.gov (United States)

    Metzger, Jutta; Corsmeier, Ulrich

    2016-04-01

    The Dead Sea is a unique place on earth. It is a terminal hypersaline lake, located at the lowest point on earth with a lake level of currently -429 m above mean sea level (amsl). It is located in a transition zone of semiarid to arid climate conditions, which makes it highly sensible to climate change (Alpert1997, Smiatek2011). The Virtual Institute DEad SEa Research Venue (DESERVE) is an international project funded by the German Helmholtz Association and was established to study coupled atmospheric hydrological, and lithospheric processes in the changing environment of the Dead Sea. At the moment the most prominent environmental change is the lake level decline of approximately 1 m / year due to anthropogenic interferences (Gertman, 2002). This leads to noticeable changes in the fractions of the existing terrestrial surfaces - water, bare soil and vegetated areas - in the valley. Thus, the partitioning of the net radiation in the valley changes as well. To thoroughly study the atmospheric and hydrological processes in the Dead Sea valley, which are driven by the energy balance components, sound data of the energy fluxes of the different surfaces are necessary. Before DESERVE no long-term monitoring network simultaneously measuring the energy balance components of the different surfaces in the Dead Sea valley was available. Therefore, three energy balance stations were installed at three characteristic sites at the coast-line, over bare soil, and within vegetation, measuring all energy balance components by using the eddy covariance method. The results show, that the partitioning of the energy into sensible and latent heat flux on a diurnal scale is totally different at the three sites. This results in gradients between the sites, which are e.g. responsible for the typical diurnal wind systems at the Dead Sea. Furthermore, driving forces of evapo-transpiration at the sites were identified and a detailed analysis of the daily evaporation and dew deposition rates

  14. Active condensation of water by plants

    Directory of Open Access Journals (Sweden)

    Prokhorov Alexey Anatolievich

    2013-10-01

    Full Text Available This paper is devoted to some peculiarities of water condensation on the surface of plants . Arguments in support of the hypothesis that in decreasing temperature of leaves and shoots below the dew point, the plant can actively condense moisture from the air, increasing the duration of dewfall are presented. Evening dewfall on plant surfaces begins before starting the formation of fog. Morning condensation continues for some time after the air temperature exceeds the dew point . The phenomenon in question is found everywhere, but it is particularly important for plants in arid ecosystems.

  15. Digital Earth Watch (DEW): How Mobile Apps Are Paving The Way Towards A Federated Web-Services Architecture For Citizen Science

    Science.gov (United States)

    Carrera, F.; Schloss, A. L.; Guerin, S.; Beaudry, J.; Pickle, J.

    2011-12-01

    Dozens of web-based initiatives allow citizens to provide information to programs that monitor the health of our environment. A concerned citizen can participate on-line as a weather "spotter", provide important phenological information to national databases, update bird counts in the area, or record the freezing of ponds, and much more. Many of these programs are developing mobile apps as companion tools to their web sites. Our group was involved in the development of one such companion app as an adjunct to the Picture Post project web site. Digital Earth Watch (DEW) and the Picture Post network support environmental monitoring through repeat digital photography and satellite imagery. A Picture Post is an eight-sided platform on a stand-alone post for taking a panoramic series of photographs. By taking pictures on a regular basis at Picture Post sites and by sharing these pictures on the program's web site (housed at the University of New Hampshire), citizen scientists are creating a photographic library of change-over-time in their local area and contributing to national monitoring programs. Our DEW Android application simplifies participation by allowing users to upload pictures instantly from their smart phone. The app also removes the constraint of the physical picture post, by allowing users to create a virtual post anywhere in the world. Posts have been set up to monitor trails, forests, water, wetlands, gardens and landscapes. The app uses the phone's GPS to position the virtual post in its geographic location and guides the user through the orientations thanks to the internal accelerometers and compass. To aid in the before-and-after comparison of images taken from the same orientation, the DEW app displays an "onionskin" of the prior image overlayed onto the camera viewfinder. With the transparent onionskin as a guide, the user can align the images more accurately, thus allowing differences between pictures to be detectable and measurable. The app

  16. Detection of pressure tube leaks relying on moisture beetles only

    International Nuclear Information System (INIS)

    Kenchington, J.M.; Choi, A.; Jin, Y.

    2004-01-01

    A major decision was made for Pickering NGS A Annulus Gas System (ACS) that detection of a pressure tube (PT) leak should be achieved by using only moisture beetles and that dew point monitors would provide 'early warning' without status to shut down the reactor. Experience with Unit 3 has shown that dew point monitoring of pressure tube leaks was particularly subject to gas leaks and surface adsorption effects. Unit 4 was the first one to be converted during the full scale pressure tube replacement programme. Because of the fundamental change in design philosophy, moisture injection tests were carried out during commissioning to demonstrate that performance matched design. In particular it was necessary to show that leak before break (LBB) would be achieved if a leak occurred in the limiting string. Units 1 and 3 have since been converted. No decision has been taken to convert Pickering B units as gas leaks are small and no significant adsorption effects are anticipated. Hence dew point monitoring will not be impaired. (author)

  17. Machine-Learning Techniques for the Determination of Attrition of Forces Due to Atmospheric Conditions

    Science.gov (United States)

    2018-02-01

    selected as a proof of concept due to its vast number of data points. While this report does note some trends associated with temperature and dew...separate data sets for helicopters and airplanes, while selectively requesting the event IDs, descriptions of events, light conditions, temperature , dew...weather events) and the error rate for that class . The rows are labeled for the actual occurrence of those events. Thus, for every row–column

  18. Effects of temperature at constant air dew point on leaf carboxylation efficiency and CO2 compensation point of different leaf types.

    Science.gov (United States)

    Weber, J A; Tenhunen, J D; Lange, O L

    1985-09-01

    The effect of temperature on photosynthesis at constant water-vapor pressure in the air was investigated using two sclerophyll species, Arbutus unedo and Quercus suber, and one mesophytic species, Spinacia oleracea. Photosynthesis and transpiration were measured over a range of temperatures, 20-39° C. The external concentration of CO2 was varied from 340 μbar to near CO2 compensation. The initial slope (carboxylation efficiency, CE) of the photosynthetic response to intercellular CO2 concentration, the CO2 compensation point (Γ), and the extrapolated rate of CO2 released into CO2-free air (R i) were calculated. At an external CO2 concentration of 320-340 μbar CO2, photosynthesis decreased with temperature in all species. The effect of temperature on Γ was similar in all species. While CE in S. oleracea changed little with temperature, CE decreased by 50% in Q. suber as temperature increased from 25 to 34° C. Arbutus unedo also exhibited a decrease in CE at higher temperatures but not as marked as Q. suber. The absolut value of R i increased with temperature in S. oleracea, while changing little or decreasing in the sclerophylls. Variations in Γ and R i of the sclerophyll species are not consistent with greater increase of respiration with temperature in the light in these species compared with S. oleracea.

  19. Reactivities of acid and/or tetralin pretreated Wandoan coal for a Curie point flash pyrolysis; Sanzen shori, tetralin yobaimae shori Wandoan tan no kyusoku netsubunkai

    Energy Technology Data Exchange (ETDEWEB)

    Kishino, M.; Sakanishi, K.; Korai, Y.; Mochida, I. [Kyushu University, Fukuoka (Japan). Institute of Advanced Material Study

    1996-10-28

    Discussions were given on effects of acid pretreatment and tetralin swelling in Wandoan coal on a Curie point flash pyrolysis (which used a Curie point pyrolyzer). Residue yield loss effects were obtained at 3.9% in hydrochloric acid pretreatment, and 6.2% in acetic acid pretreatment. The effects of tetralin swelling pretreatment were compared in the similar manner in terms of the residue yield loss. The effects were 4.0% in untreated coal, 2.0% in the hydrochloric acid pretreatment, and 0.6% in the acetic acid pretreatment. It is thought that components that can be activated by acetic acid have already been activated, but the remaining components would not be activated by tetralin. Average microporosity (area) in the remaining particle as a whole shows very little difference both in acetic acid pretreated coal and untreated coal. However, with the acetic acid pretreatment, pores smaller than 4{mu}m{sup 2} disappeared, and pores as large as 205 to 411{mu}m{sup 2} increased largely. This phenomenon was observed as an increase in foaming degree under microscopic observation, even if the average microporosity remains equal. Thermoplasticity of the coal increased, and so did volatilization reactivity as a result of the acetic acid pretreatment, resulting in appearance of a large number of large pores. 6 refs., 2 figs., 2 tabs.

  20. Fatty Acid and Carbon Isotopic Evidence for type I Methanotrophs in Microbial Mats from a Shallow Marine Gas Seep, Coal Oil Point, CA.

    Science.gov (United States)

    Ding, H.; Valentine, D.

    2005-12-01

    To study the microbial community in a Southern California seep field, sediment and bacterial mat samples were collected from natural gas-bearing and gas-free surfaces at two distinct seeps in the Coal Oil Point seep field, offshore Santa Barbara. Fatty acids in these samples were extracted, analyzed and identified. Using gas chromatography (GC), more than 30 different fatty acids were separated. Generally, fatty acid concentrations in natural gas-bearing samples were about 5-fold higher compared to gas-free samples. Using gas chromatography mass sepctrometry (GC-MS), all separated fatty acids were identified in each sample. The major constituents included saturated 14:0, 16:0, 18:0, branched i-15, a-15 and unsaturated 16:1 and 18:1 series fatty acids. GC-IRMS (isotope ratio mass spectrometry) analysis provided the 13C of all major fatty acids and some 16:1 series fatty acids were found to be more depleted than -40% in samples associated with gas seepage. After treatment with dimethyl disufide (DMDS), the 16:1 series fatty acids were resolved into five distinct components, including common composition 16:1(7), bacterial specific i-16:1(7) and typical biomarkers of type I methnotrophs 16:1(8), 16(6) and 16:1(5), suggesting an important role for methnotrophs in seep sediments and microbial mats. These results provide evidence for the activity of type I methanotrophic bacteria in microbial mats and surficial sediments at the Coal Oil Point seep field, and have implications for methane cycling in this and other seep

  1. Implementation of antimicrobial peptides for sample preparation prior to nucleic acid amplification in point-of-care settings.

    Science.gov (United States)

    Krõlov, Katrin; Uusna, Julia; Grellier, Tiia; Andresen, Liis; Jevtuševskaja, Jekaterina; Tulp, Indrek; Langel, Ülo

    2017-12-01

    A variety of sample preparation techniques are used prior to nucleic acid amplification. However, their efficiency is not always sufficient and nucleic acid purification remains the preferred method for template preparation. Purification is difficult and costly to apply in point-of-care (POC) settings and there is a strong need for more robust, rapid, and efficient biological sample preparation techniques in molecular diagnostics. Here, the authors applied antimicrobial peptides (AMPs) for urine sample preparation prior to isothermal loop-mediated amplification (LAMP). AMPs bind to many microorganisms such as bacteria, fungi, protozoa and viruses causing disruption of their membrane integrity and facilitate nucleic acid release. The authors show that incubation of E. coli with antimicrobial peptide cecropin P1 for 5 min had a significant effect on the availability of template DNA compared with untreated or even heat treated samples resulting in up to six times increase of the amplification efficiency. These results show that AMPs treatment is a very efficient sample preparation technique that is suitable for application prior to nucleic acid amplification directly within biological samples. Furthermore, the entire process of AMPs treatment was performed at room temperature for 5 min thereby making it a good candidate for use in POC applications.

  2. Summary of PWR leak detection studies

    International Nuclear Information System (INIS)

    Cho, J.H.; Elia, F.A. Jr.

    1986-01-01

    Thermal-hydraulic analysis can be used to determine the location and magnitude of leaks inside and location of leaks outside a pressurized water reactor (PWR) containment as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside containment. Plant-specific analyses are utilized to predict change in parameters such as local dew point temperature, relative humidity, dry bulb temperature, and flow rate to sump for various leak rates and enthalpies. These parameter responses are then programmed into the plant computer and instrumentation is provided for area monitoring. The actual inputs are continuously monitored and compared to the predicted plant responses to identify the leak location and quantify the leak. This study concludes that a system that monitors dew point (or relative humidity) and dry bulb temperature changes together with the flow rate to the sump will provide the capability to both locate and quantify a leak inside a containment, while a system that monitors dew point temperature (or relative humidity) changes will provide the capability to locate a leak outside a containment

  3. Dew Point Temperature Affects Ascospore Release of Allergenic Genus Leptosphaeria

    OpenAIRE

    Sadyś, M.; Kaczmarek, J.; Grinn-Gofron, A.; Rodinkova, V.; Prikhodko, A.; Bilous, E.; Strzelczak, A.; Herbert, Rob; Jedryczka, M.

    2018-01-01

    The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs...

  4. Photovoltaic High-Frequency Pulse Charger for Lead-Acid Battery under Maximum Power Point Tracking

    Directory of Open Access Journals (Sweden)

    Hung-I. Hsieh

    2013-01-01

    Full Text Available A photovoltaic pulse charger (PV-PC using high-frequency pulse train for charging lead-acid battery (LAB is proposed not only to explore the charging behavior with maximum power point tracking (MPPT but also to delay sulfating crystallization on the electrode pores of the LAB to prolong the battery life, which is achieved due to a brief pulse break between adjacent pulses that refreshes the discharging of LAB. Maximum energy transfer between the PV module and a boost current converter (BCC is modeled to maximize the charging energy for LAB under different solar insolation. A duty control, guided by a power-increment-aided incremental-conductance MPPT (PI-INC MPPT, is implemented to the BCC that operates at maximum power point (MPP against the random insolation. A 250 W PV-PC system for charging a four-in-series LAB (48 Vdc is examined. The charging behavior of the PV-PC system in comparison with that of CC-CV charger is studied. Four scenarios of charging statuses of PV-BC system under different solar insolation changes are investigated and compared with that using INC MPPT.

  5. An integrated paper-based sample-to-answer biosensor for nucleic acid testing at the point of care.

    Science.gov (United States)

    Choi, Jane Ru; Hu, Jie; Tang, Ruihua; Gong, Yan; Feng, Shangsheng; Ren, Hui; Wen, Ting; Li, XiuJun; Wan Abas, Wan Abu Bakar; Pingguan-Murphy, Belinda; Xu, Feng

    2016-02-07

    With advances in point-of-care testing (POCT), lateral flow assays (LFAs) have been explored for nucleic acid detection. However, biological samples generally contain complex compositions and low amounts of target nucleic acids, and currently require laborious off-chip nucleic acid extraction and amplification processes (e.g., tube-based extraction and polymerase chain reaction (PCR)) prior to detection. To the best of our knowledge, even though the integration of DNA extraction and amplification into a paper-based biosensor has been reported, a combination of LFA with the aforementioned steps for simple colorimetric readout has not yet been demonstrated. Here, we demonstrate for the first time an integrated paper-based biosensor incorporating nucleic acid extraction, amplification and visual detection or quantification using a smartphone. A handheld battery-powered heating device was specially developed for nucleic acid amplification in POC settings, which is coupled with this simple assay for rapid target detection. The biosensor can successfully detect Escherichia coli (as a model analyte) in spiked drinking water, milk, blood, and spinach with a detection limit of as low as 10-1000 CFU mL(-1), and Streptococcus pneumonia in clinical blood samples, highlighting its potential use in medical diagnostics, food safety analysis and environmental monitoring. As compared to the lengthy conventional assay, which requires more than 5 hours for the entire sample-to-answer process, it takes about 1 hour for our integrated biosensor. The integrated biosensor holds great potential for detection of various target analytes for wide applications in the near future.

  6. Fluoroplastic materials for pressure tubes in flue gas heat exchangers under corrosive conditions of flue gas desulfurisation plants; Fluorkunststoffe fuer Druckrohre in Rauchgaswaermetauschern unter korrosiven Bedingungen fuer die Rauchgasentschwefelung

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalk-Gaudig, Gabriele [Dyneon GmbH, Burgkirchen (Germany); Broda, Siegfried [Heatec Co., Ltd., Chonburi (Thailand); Adamczyk, Frank; Kreilos, Klaus [Babcock Borsig Service GmbH, Oberhausen (Germany). Bereich Waermenutzung

    2010-07-01

    Since the 1980s, power plants have been required to have flue gas desulphurising plants. For the cooling of flue gases to below the acid dew point and subsequent reheating, corrosion-resistant gas-gas heat exchanger systems had already been developed at this time by what is now Babcock Borsig Service GmbH (BBS). The best results were achieved using 100 % plastic piping as a vital component. In addition to the development of the plastic heat exchangers and the differences in design relative to alternative models, the various types of fluoroplastics will be discussed, and in particular the difference between PFA and PTFE. (orig.)

  7. The Climatology Module CLIMAT

    National Research Council Canada - National Science Library

    Avara, Elton

    1998-01-01

    ... (temperature, dew point temperature, absolute humidity, relative humidity, horizontal visibility, sea level pressure, wind speed, wind direction, cloudbase height, cloud cover, and Pasquill stability category...

  8. EOS simulation and GRNN modeling of the constant volume depletion behavior of gas condensate reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Elsharkawy, A.M.; Foda, S.G. [Kuwait University, Safat (Kuwait). Petroleum Engineering Dept.

    1998-03-01

    Currently, two approaches are being used to predict the changes in retrograde gas condensate composition and estimate the pressure depletion behavior of gas condensate reservoirs. The first approach uses the equation of states whereas the second uses empirical correlations. Equations of states (EOS) are poor predictive tools for complex hydrocarbon systems. The EOS needs adjustment against phase behavior data of reservoir fluid of known composition. The empirical correlation does not involve numerous numerical computations but their accuracy is limited. This study presents two general regression neural network (GRNN) models. The first model, GRNNM1, is developed to predict dew point pressure and gas compressibility at dew point using initial composition of numerous samples while the second model, GRNNM2, is developed to predict the changes in well stream effluent composition at any stages of pressure depletion. GRNNM2 can also be used to determine the initial reservoir fluid composition using dew point pressure, gas compressibility at dew point, and reservoir temperature. These models are based on analysis of 142 sample of laboratory studies of constant volume depletion (CVD) for gas condensate systems forming a total of 1082 depletion stages. The database represents a wide range of gas condensate systems obtained worldwide. The performance of the GRNN models has been compared to simulation results of the equation of state. The study shows that the proposed general regression neural network models are accurate, valid, and reliable. These models can be used to forecast CVD data needed for many reservoir engineering calculations in case laboratory data is unavailable. The GRNN models save computer time involved in EOS calculations. The study also show that once these models are properly trained they can be used to cut expenses of frequent sampling and laborious experimental CVD tests required for gas condensate reservoirs. 55 refs., 13 figs., 6 tabs.

  9. Parameter measurement of target

    International Nuclear Information System (INIS)

    Gao Dangzhong

    2001-01-01

    The progress of parameter measurement of target (ICF-15) in 1999 are presented, including the design and contract of the microsphere equator profiler, the precise air bearing manufacturing, high-resolution X-ray image of multi-layer shells and the X-ray photos processed with special image and data software, some plastic shells measured in precision of 0.3 μm, the high-resolution observation and photograph system of 'dew-point method', special fixture of target and its temperature distribution measuring, the dew-point temperature and fuel gas pressure of shells measuring with internal pressure of 5 - 15 (x10 5 ) Pa D 2 and wall thickness of 1.5∼3 μm

  10. Determination of the Acidity of Oils Using Paraformaldehyde as a Thermometric End-Point Indicator

    Directory of Open Access Journals (Sweden)

    Carneiro Mário J. D.

    2002-01-01

    Full Text Available The determination of the acidity of oils by catalytic thermometric titrimetry using paraformaldehyde as the thermometric end-point indicator was investigated. The sample solvent was a 1:1 (v/v mixture of toluene and 2-propanol and the titrant was 0.1 mol L-1 aqueous sodium hydroxide. Paraformaldehyde, being insoluble in the sample solvent, does not present the inconvenience of other indicators that change the properties of the solvent due to composition changes. The titration can therefore be done effectively in the same medium as the standard potentiometric and visual titration methods. The results of the application of the method to both non-refined and refined oils are presented herein. The proposed method has advantages in relation to the potentiometric method in terms of speed and simplicity.

  11. Nowcasting Surface Meteorological Parameters Using Successive Correction Method

    National Research Council Canada - National Science Library

    Henmi, Teizi

    2002-01-01

    The successive correction method was examined and evaluated statistically as a nowcasting method for surface meteorological parameters including temperature, dew point temperature, and horizontal wind vector components...

  12. Equipment-free nucleic acid extraction and amplification on a simple paper disc for point-of-care diagnosis of rotavirus A.

    Science.gov (United States)

    Ye, Xin; Xu, Jin; Lu, Lijuan; Li, Xinxin; Fang, Xueen; Kong, Jilie

    2018-08-14

    The use of paper-based methods for clinical diagnostics is a rapidly expanding research topic attracting a great deal of interest. Some groups have attempted to realize an integrated nucleic acid test on a single microfluidic paper chip, including extraction, amplification, and readout functions. However, these studies were not able to overcome complex modification and fabrication requirements, long turn-around times, or the need for sophisticated equipment like pumps, thermal cyclers, or centrifuges. Here, we report an extremely simple paper-based test for the point-of-care diagnosis of rotavirus A, one of the most common pathogens that causes pediatric gastroenteritis. This paper-based test could perform nucleic acid extraction within 5 min, then took 25 min to amplify the target sequence, and the result was visible to the naked eye immediately afterward or quantitative by the UV-Vis absorbance. This low-cost method does not require extra equipment and is easy to use either in a lab or at the point-of-care. The detection limit for rotavirus A was found to be 1 × 10 3 copies/mL. In addition, 100% sensitivity and specificity were achieved when testing 48 clinical stool samples. In conclusion, the present paper-based test fulfills the main requirements for a point-of-care diagnostic tool, and has the potential to be applied to disease prevention, control, and precision diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Warm Season Statistical Verification of the Pennsylvania State University Real Time Mesoscale Model Version 5

    National Research Council Canada - National Science Library

    Fitzgerald, Mark

    1998-01-01

    .... Variables that are verified include temperature, dew point, relative humidity, wind direction, wind speed, geopotential height, sea-level pressure, as well as the total totals severe weather index...

  14. Development of a Weather Running Estimate-Nowcast Capability for the U.S. Army IMETS

    National Research Council Canada - National Science Library

    Henmi, Teizi; Dumais, Robert; Okrasinski, Richard

    2005-01-01

    ...) forecast, surface, and upper-air sounding data, are used for the computation. Three-dimensional distributions of temperature, dew-point temperature, and horizontal wind vector components can be forecasted...

  15. Initiation points for cellular deoxyribonucleic acid replication in human lymphoid cells converted by Epstein-Barr virus

    International Nuclear Information System (INIS)

    Oppenheim, A.; Shlomai, Z.; Ben-Bassat, H.

    1981-01-01

    Replicon size was estimated in two Epstein-Barr virus (EBV)-negative human lymphoma lines, BJAB and Ramos, and four EBV-positive lines derived from the former ones by infection (conversion) with two viral strains, B95-8 and P3HR-1. Logarithmic cultures were pulse-labeled with [/sup -3/H]thymidine, and the deoxyribonucleic acid was spread on microscopic slides and autoradiographed by the method of Huberman and Riggs. Three of the four EBV-converted cell lines, BJAB/B95-8, Ra/B95-8, and Ra/HRIK, were found to have significantly shorter replicons (41, 21, 54% shorter, respectively), i.e., more initiation points, than their EBV-negative parents. BJAB/HRIK had replicons which were only slightly shorter (11%) than those of BJAB. However, analysis of track length demonstrated that extensive track fusion occurred during the labeling of BJAB/HRIK, implying that its true average replicon size is shorter than the observed value. The results indicate that in analogy to simian virus 40, EBV activates new initiation points for cellular DNA replication in EBV-transformed cells

  16. Experimental phase behavior study of a five-component model gas condensate

    NARCIS (Netherlands)

    Shariati - Sarabi, A.; Straver, E.J.M.; Florusse, L.J.; Peters, C.J.

    2014-01-01

    In this work, the bubble points and dew points of a multicomponent mixture of methane, butane, heptane, decane and tetradecane as a model mixture representative of a gas condensate, have been measured experimentally. Ten samples with approximately the same composition were prepared and their

  17. Reduction of Acid-Fast and Non-Acid-Fast Bacteria by Point of Use Coagulation-Flocculation-Disinfection

    Directory of Open Access Journals (Sweden)

    Lisa M. Casanova

    2015-11-01

    Full Text Available Point of use (POU household water treatment is increasingly being adopted as a solution for access to safe water. Non-tuberculous Mycobacteria (NTM are found in water, but there is little research on whether NTM survive POU treatment. Mycobacteria may be removed by multi-barrier treatment systems that combine processes such as coagulation, settling and disinfection. This work evaluated removal of a non-tuberculous Mycobacterium (Mycobaterium terrae and a Gram-negative non-acid-fast environmental bacterium (Aeromonas hydrophila by combined coagulation-flocculation disinfection POU treatment. Aeromonas hydrophila showed 7.7 log10 reduction in demand free buffer, 6.8 log10 in natural surface water, and 4 log10 reduction in fecally contaminated surface water. Turbidity after treatment was <1 NTU. There was almost no reduction in levels of viable M. terrae by coagulant-flocculant-disinfectant in natural water after 30 minutes. The lack of Mycobacteria reduction was similar for both combined coagulant-flocculant-disinfectant and hypochlorite alone. A POU coagulant-flocculant-disinfectant treatment effectively reduced A. hydrophila from natural surface waters but not Mycobacteria. These results reinforce previous findings that POU coagulation-flocculation-disinfection is effective against gram-negative enteric bacteria. POU treatment and safe storage interventions may need to take into account risks from viable NTM in treated stored water and consider alternative treatment processes to achieve NTM reductions.

  18. 75 FR 2860 - Clean Water Act Section 303(d): Call for Data for the Illinois River Watershed in Oklahoma and...

    Science.gov (United States)

    2010-01-19

    ... movement, solar radiation, dew-point temperature, and cloud cover. Daily data for the 1980-2010 time... lengths and slopes, cross-sections and geometry, bed composition (sediment particle sizes, nutrients...

  19. Optimization of a Nucleic Acids united-RESidue 2-Point model (NARES-2P) with a maximum-likelihood approach

    International Nuclear Information System (INIS)

    He, Yi; Scheraga, Harold A.; Liwo, Adam

    2015-01-01

    Coarse-grained models are useful tools to investigate the structural and thermodynamic properties of biomolecules. They are obtained by merging several atoms into one interaction site. Such simplified models try to capture as much as possible information of the original biomolecular system in all-atom representation but the resulting parameters of these coarse-grained force fields still need further optimization. In this paper, a force field optimization method, which is based on maximum-likelihood fitting of the simulated to the experimental conformational ensembles and least-squares fitting of the simulated to the experimental heat-capacity curves, is applied to optimize the Nucleic Acid united-RESidue 2-point (NARES-2P) model for coarse-grained simulations of nucleic acids recently developed in our laboratory. The optimized NARES-2P force field reproduces the structural and thermodynamic data of small DNA molecules much better than the original force field

  20. Measurement of Vapor Flow As an Important Source of Water in Dry Land Eco-Hydrology

    Science.gov (United States)

    Wang, Z.; He, Z.; Wang, Y.; Gao, Z.; Hishida, K.

    2014-12-01

    When the temperature of land surface is lower than that of air and deeper soils, water vapor gathers toward the ground surface where dew maybe formed depending on the prevailing dew point and wind speed. Some plants are able to absorb the dew and vapor flow while the soil can readily absorb both. Certain animals such as desert beetles and ants harvest the dew or fog for daily survival. Recently, it is also realized that the dew and vapor flow can be a life-saving amount of water for plant survival at the driest seasons of the year in arid and semi-arid regions. Researches are conducted to quantify the amount of near-surface vapor flow in arid and semi-arid regions in China and USA. Quantitative leaf water absorption and desorption functions were derived based on laboratory experiments. Results show that plant leaves absorb and release water at different speeds depending on species and varieties. The "ideal" native plants in the dry climates can quickly absorb water and slowly release it. This water-holding capacity of plant is characterized by the absorption and desorption functions derived for plant physiology and water balance studies. Field studies are conducted to measure the dynamic vapor flow movements from the atmosphere and the groundwater table to soil surface. Results show that dew is usually formed on soil and plant surfaces during the daily hours when the temperature gradients are inverted toward the soil surface. The amount of dew harvested using gravels on the soil surface was enough to support water melon agriculture on deserts. The vapor flow can be effectively intercepted by artificially seeded plants in semi-arid regions forming new forests. New studies are attempted to quantify the role of vapor flow for the survival of giant sequoias in the southern Sierra Nevada Mountains of California.

  1. Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity

    Science.gov (United States)

    Gartia, Manas R.; Misra, Santosh K.; Ye, Mao; Schwartz-Duval, Aaron; Plucinski, Lisa; Zhou, Xiangfei; Kellner, David; Labriola, Leanne T.; Pan, Dipanjan

    2015-11-01

    Limited training, high cost, and low equipment mobility leads to inaccuracies in decision making and is concerning with serious ocular injuries such as suspected ruptured globe or post-operative infections. Here, we present a novel point-of-service (POS) quantitative ascorbic acid (AA) assay with use of the OcuCheck Biosensor. The present work describes the development and clinical testing of the paper-based biosensor that measures the changes in electrical resistance of the enzyme-plated interdigitated electrodes to quantify the level of AA present in ocular fluid. We have demonstrated the proof-of-concept of the biosensor testing 16 clinical samples collected from aqueous humor of patients undergoing therapeutic anterior chamber paracentesis. Comparing with gold standard colorimetric assay for AA concentration, OcuCheck showed accuracy of >80%, sensitivity of >88% and specificity of >71%. At present, there are no FDA-approved POS tests that can directly measures AA concentration levels in ocular fluid. We envisage that the device can be realized as a handheld, battery powered instrument that will have high impact on glaucoma care and point-of-care diagnostics of penetrating ocular globe injuries.

  2. Fluid flow behaviour of gas-condensate and near-miscible fluids at the pore scale

    Energy Technology Data Exchange (ETDEWEB)

    Dawe, Richard A. [Department of Chemical Engineering, University of West Indies, St. Augustine (Trinidad and Tobago); Grattoni, Carlos A. [Department of Earth Science and Engineering, Imperial College, London, SW7 2BP (United Kingdom)

    2007-02-15

    Retrograde condensate reservoir behaviour is complex with much of the detailed mechanisms of the multiphase fluid transport and mass transfer between the phases within the porous matrix still speculative. Visual modelling of selected processes occurring at the pore level under known and controlled boundary conditions can give an insight to fluid displacements at the core scale and help the interpretation of production behaviour at reservoir scale. Visualisation of the pore scale two-phase flow mechanisms has been studied experimentally at low interfacial tensions, < 0.5 mN/m, using a partially miscible fluid system in glass visual micro models. As the interfacial tension decreases the balance between fluid-fluid forces (interfacial, spreading and viscous) and fluid-solid interactions (wettability and viscous interactions) changes. Data measurements in the laboratory, particularly relative permeability, will therefore always be difficult especially for condensate fluids just below their dew point. What is certain is that gas production from a gas-condensate leads to condensate dropout when pressure falls below the dew point, either within the wellbore or, more importantly, in the reservoir. This paper illustrates some pore scale physics, particularly interfacial phenomena at low interfacial tension, which has relevance to appreciating the flow of condensate fluids close to their dew point either near the wellbore (which affects well productivity) or deep inside the reservoir (which affects condensate recovery). (author)

  3. Statistical Studies of Mesoscale Forecast Models MM5 and WRF

    National Research Council Canada - National Science Library

    Henmi, Teizi

    2004-01-01

    ... models were carried out and the results were compared with surface observation data. Both models tended to overforecast temperature and dew-point temperature, although the correlation coefficients between forecast and observations were fairly high...

  4. Evaluation of corrosion attack of chimney liners

    Directory of Open Access Journals (Sweden)

    Blahetová M.

    2016-06-01

    Full Text Available The case study of chimney liner corrosion addresses three specific cases of damage of chimney systems from of stainless steels. These systems were used for flue of gas arising from the combustion of brown coal in small automatic boilers, which are used for heating. Detailed analyzes implied that the cause of devastating corrosion of the steel AISI 316 and 304 steel (CSN 17349, 17241 was particularly high content of halides (chlorides and fluorides, which caused a severe pitting corrosion, which led up to the perforation of the liner material. Simultaneous reduction of the thickness of the used sheets was due to by the general corrosion, which was caused by the sulfur in the solid fuel. The condensation then led to acid environment and therefore the corrosion below the dew point of the sulfuric acid has occurred. All is documented by metallographic analysis and microanalysis of the corrosion products.

  5. Adsorption based processes as alternative to common gas conditioning at underground storage facilities using Sorbead; Procedes bases sur l'adsorption comme solution de rechange dans le conditionnement du gaz dans des lieux de stockage souterrains a l'aide de Sorbead

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Th. [Engelhard Process Chemicals GmbH (Germany)

    2000-07-01

    The European gas market is continuing to expand due to increased industrial, domestic and power generation demand. As a result of this demand, and the trend toward liberalization of the market, the need for storage of gas is also increasing. One key segment of the large scale storage of gas is underground storage, either in partially depleted gas or oil fields, naturally occurring caverns, aquifers and salt cavities. In most cases the gas produced after storage requires conditioning to meet the water of hydrocarbon dew point specification of the gas transmission system. For that reason export gas from storage will require gas conditioning in order to meet pipeline specifications. Adsorption as a feasible and reliable process will be presented in detail and especially in regards to hydrocarbon dew-pointing compared with other process options. (author)

  6. Test Plan Development for Plastic Ammunition Containers. Volume 1

    Science.gov (United States)

    1989-03-15

    constituents such as humidity/ moisture/dew formation and localized environmental constituents (ozone, smog, acid rain, etc.). Although this approach...acceptable degree of durability in excess of 12 years. 31 STUDY OF THE AGEING RESISTANCE UNDER NATURAL CLIMATIC CONDITIONS OF POLYMETHACRYLATE ...polymerized from a mixture of unsatu- rated and saturated acids or anhydrides. The unsaturates provide sites for reaction with the monomer, while the

  7. Isosbestic points in the quality control oF spectrophotometers

    International Nuclear Information System (INIS)

    Oliveira, E.M. de.

    1987-01-01

    The methodology and results of quality control of spectrophotometers are reported and the calibrating of the monochromator by isosbestic points is presented. Four colorimetric indicators are used. The absorption curves (in acid and alkaline media) and mathematic determination of the common junction point are used for indicated the isosbetic points. (M.A.C.) [pt

  8. Association between weather conditions and the number of patients at the emergency room in an Argentine hospital

    Science.gov (United States)

    Rusticucci, Matilde; Bettolli, Laura M.; de los Angeles Harris, M.

    2002-02-01

    The aim of this paper is to study the relationships between hospital emergencies and weather conditions by analysing summer and winter cases of patients requiring attention at the emergency room of a hospital in the city of Buenos Aires, Argentina. Hospital data have been sorted into seven different diagnostic groups as follows: (1) respiratory, cardiovascular and chest-pain complaints; (2) digestive, genitourinary and abdominal complaints; (3) neurological and psychopathological disorders; (4) infections; (5) contusion and crushing, bone and muscle complaints; (6) skin and allergies and (7) miscellaneous complaints. In general, there is an increase of 16.7% in winter while, for group 2 and group 6, there are more patients in summer, 54% and 75% respectively. In summer, the total number of patients for group 6 shows a significant positive correlation with temperature and dew-point temperature, and a negative correlation with the sea-level pressure for the same day. In winter, the same relationship exists, however its correlation is not as strong. The lags observed between these three variables: maximum dew-point temperature, maximum temperature, minimum air pressure and the peaks in admissions are 1, 2 and 4 days respectively. In winter, increases in temperature and dew point and decreases in pressure are followed by a peak in admissions for group 2. In winter, there are significantly more cases in group 5 on warm, dry days and on warm, wet days in the summer.

  9. Un versión española de la Escala de Estrategias de Afrontamiento de Maestros ante Estresores Laborales (Dewe, 1985

    Directory of Open Access Journals (Sweden)

    T. LOZANO-YAGÜE

    2003-01-01

    Full Text Available El objetivo propuesto fue adaptar la escala de Estrategias de Afrontamiento utilizadas por los Maestros ante Estresores Laborales (Dewe, 1985 a los docentes no universitarios españoles. Con tal propósito, la versión resultante del proceso de traducción-retrotraducción fue autocumplimentada, junto a otras escalas de referencia, por 172 docentes no universitarios dependientes del Ministerio de Educación y Cultura (M.E.C., analizándose posteriormente su fiabilidad (análisis factorial y análisis de la consistencia interna y validez (matriz de correlaciones. La versión obtenida resultó, a juicio de los participantes en la traducciónretrotraducción, equivalente conceptual, técnica y semánticamente con la versión original. A partir de dicha versión se consiguió una escala reducida compuesta de cinco factores y 27 variables, con unas adecuadas validez de contenido y de constructo (validez convergente y discriminante y fiabilidad (coeficiente alfa de Cronbach, ¿>0,7, para su aplicación en nuestro medio.

  10. Optimization of the 3-Point Bending Failure of Anodized Aluminum Formed in Tartaric/Sulphuric Acid Using Doehlert Design

    Science.gov (United States)

    Bensalah, W.; Feki, M.; De-Petris Wery, M.; Ayedi, H. F.

    2015-02-01

    The bending failure of anodized aluminum in tartaric/sulphuric acid bath was modeled using Doehlert design. Bath temperature, anodic current density, sulphuric acid, and tartaric acid concentrations were retained as variables. Thickness measurements and 3-point bending experiments were conducted. The deflection at failure ( D f) and the maximum load ( F m) of each sample were, then, deducted from the corresponding flexural responses. The treatment of experimental results has established mathematical models of second degree reflecting the relation of cause and effect between the factors and the studied properties. The optimum path study of thickness, deflection at failure, and maximum load, showed that the three optima were opposite. Multicriteria optimization using the desirability function was achieved in order to maximize simultaneously the three responses. The optimum conditions were: C tar = 18.2 g L-1, T = 17.3 °C, J = 2.37 A dm-2, C sul = 191 g L-1, while the estimated response values were e = 57.7 µm, D f = 5.6 mm, and F m = 835 N. Using the established models, a mathematical correlation was found between deflection at failure and thickness of the anodic oxide layer. Before bending tests, aluminum oxide layer was examined by scanning electron microscopy (SEM) and atomic force microscopy. After tests, the morphology and the composition of the anodic oxide layer were inspected by SEM, optical microscopy, and glow-discharge optical emission spectroscopy.

  11. Synthesis of polymeric additives based on itaconic acid and their evaluation as pour point depressants for lube oil in relation to rheological flow properties

    Directory of Open Access Journals (Sweden)

    A.M. Al-Sabagh

    2012-06-01

    Full Text Available Modification of the wax crystal habit practical interest during transportation processing of lube oil at low temperature. Various pour point depressant (PPD additives can facilitate this modification by different mechanisms. Comb shaped polymer additives are known to depress the pour point of lube oil by providing different nucleation sites for the precipitation of wax. This paper describes performance based design, synthesis, characterization and evaluation of comb shaped polymeric additives. Alkyl itaconates were prepared by the esterification of itaconic acid with different saturated alcohols C16/C18/NAFOL 20+A (Cav = 20/NAFOL 1822 B (Cav = 22. The four synthesized monomers were characterized and copolymerized with styrene in different molar ratios. All the products were characterized by infra-red (FTIR, Nuclear Magnetic Resonance (NMR Spectroscopy and Gel permeation chromatography (GPC. Rheological properties of lube oil (with and without additives were studied by Brookfield viscometer. In this study the additives based on itaconic acid were evaluated as good PPD and rheology modifiers.

  12. Design of improved detection instrumentation for the annulus gas system for wolsong 2

    International Nuclear Information System (INIS)

    Kim, Seog Nam; Koo, Jun Mo; Chang, Ik Ho; Jung, Ho Chang; Han, Sang Joon

    1996-01-01

    The improved and advanced Annulus Gas System (AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board (AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. The improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided. 8 refs., 3 figs. (author)

  13. Validation for a new apparatus measuring water vapour enhancement factors up to 6 MPa

    International Nuclear Information System (INIS)

    Sairanen, H; Heinonen, M

    2014-01-01

    High accuracy dew-point measurements require a water vapour enhancement factor to correct the effects of pressure drop in a sampling line. The enhancement factor is also needed when a humidity quantity value is converted to another. In this paper a new apparatus for traceable measurements of the enhancement factor is presented along with the results of validation measurements with air and methane. The apparatus is designed for dew-point temperatures from −50 to +15 °C and the pressure range from atmospheric pressure up to 6 MPa. The performance of the apparatus was investigated by comparing measurement results to the literature data for air and the data calculated from published thermodynamic measurement results for methane. It is shown that the experimental results agree with the reference data within the estimated uncertainties. (paper)

  14. Particle Swarm Optimization-based BP Neural Network for UHV DC Insulator Pollution Forecasting

    Directory of Open Access Journals (Sweden)

    Fangcheng Lü

    2014-02-01

    Full Text Available In order to realize the forecasting of the UHV DC insulator's pollution conditions, we introduced a PSOBP algorithm. A BP neural network (BPNN with leakage current, temperature, relative humidity and dew point as input neurons, and ESDD as output neuron was built to forecast the ESDD. The PSO was used to optimize the the BPNN, which had great improved the convergence rate of the BP neural network. The dew point as a brand new input unit has improved the iteration speed of the PSOBP algorithm in this study. It was the first time that the PSOBP algorithm was applied to the UHV DC insulator pollution forecasting. The experiment results showed that the method had great advantages in accuracy and speed of convergence. The research showed that this algorithm was suitable for the UHV DC insulator pollution forecasting.

  15. The Use Of New Adsorption Technology

    International Nuclear Information System (INIS)

    Khattaby, M.; El-Azm, A.

    2004-01-01

    Adsorption is widely used in Gas Dehydration. Recently, new technology has been applied by using a new type of silica gel adsorbent for both gas dehydration and hydrocarbon dew pointing. A study to evaluate the different methods of hydrocarbon dew pointing was performed by Enppi and proved that the use of adsorption process with a new type of silica gel has significant cost benefits over the life of field. In Egypt, this new technology has been used in the Rosetta gas plant, which was designed for 302 MMSCFD (275 + 10%). The plant has been operational for about 4 years and experience demonstrated that the new type of silica gel has high performance, excellent reliability and low operating cost. Following these good results, the plant has been tested up to 380 MMSCFD and again the adsorbent proved its high performance and efficiency

  16. EDITORIAL: Humidity sensors Humidity sensors

    Science.gov (United States)

    Regtien, Paul P. L.

    2012-01-01

    produced at relatively low cost. Therefore, they find wide use in lots of applications. However, the method requires a material that possesses some conflicting properties: stable and reproducible relations between air humidity, moisture uptake and a specific property (for instance the length of a hair, the electrical impedance of the material), fast absorption and desorption of the water vapour (to obtain a short response time), small hysteresis, wide range of relative humidity (RH) and temperature-independent output (only responsive to RH). For these reasons, much research is done and is still going on to find suitable materials that combine high performance and low price. In this special feature, three of the four papers report on absorption sensors, all with different focus. Aziz et al describe experiments with newly developed materials. The surface structure is extensively studied, in view of its ability to rapidly absorb water vapour and exhibit a reproducible change in the resistance and capacitance of the device. Sanchez et al employ optical fibres coated with a thin moisture-absorbing layer as a sensitive humidity sensor. They have studied various coating materials and investigated the possibility of using changes in optical properties of the fibre (here the lossy mode resonance) due to a change in humidity of the surrounding air. The third paper, by Weremczuk et al, focuses on a cheap fabrication method for absorption-based humidity sensors. The inkjet technology appears to be suitable for mass fabrication of such sensors, which is demonstrated by extensive measurements of the electrical properties (resistance and capacitance) of the absorbing layers. Moreover, they have developed a model that describes the relation between humidity and the electrical parameters of the moisture-sensitive layer. Despite intensive research, absorption sensors still do not meet the requirements for high accuracy applications. The dew-point temperature method is more appropriate

  17. The effect of environmental humidity and temperature on skin barrier function and dermatitis

    DEFF Research Database (Denmark)

    Engebretsen, K A; Johansen, J D; Kezic, S

    2016-01-01

    existing dermatoses. We searched the literature for studies that evaluated the mechanisms behind this phenomenon. Commonly used meteorological terms such as absolute humidity, relative humidity and dew point are explained. Furthermore, we review the negative effect of low humidity, low temperatures...

  18. Unsteady-state analysis of a counter-flow dew point evaporative cooling system

    KAUST Repository

    Lin, J.; Thu, K.; Bui, T.D.; Wang, R.Z.; Ng, Kim Choon; Kumja, M.; Chua, K.J.

    2016-01-01

    temperature, humidity and velocity; (2) the settling time of the transient response ranges from 50 s to 300 s when the system operates under different inlet conditions; and (3) the average transient wet bulb effectiveness (1.00–1.06) of the system is observed

  19. Phase Behaviors of Reservoir Fluids with Capillary Eff ect Using Particle Swarm Optimization

    KAUST Repository

    Ma, Zhiwei

    2013-05-06

    The study of phase behavior is important for the oil and gas industry. Many approaches have been proposed and developed for phase behavior calculation. In this thesis, an alternative method is introduced to study the phase behavior by means of minimization of Helmholtz free energy. For a system at fixed volume, constant temperature and constant number of moles, the Helmholtz free energy reaches minimum at the equilibrium state. Based on this theory, a stochastic method called Particle Swarm Optimization (PSO) algorithm, is implemented to compute the phase diagrams for several pure component and mixture systems. After comparing with experimental and the classical PT-ash calculation, we found the phase diagrams obtained by minimization of the Helmholtz Free Energy approach match the experimental and theoretical diagrams very well. Capillary effect is also considered in this thesis because it has a significant influence on the phase behavior of reservoir fluids. In this part, we focus on computing the phase envelopes, which consists of bubble and dew point lines. Both fixed and calculated capillary pressure from the Young-Laplace equation cases are introduced to study their effects on phase envelopes. We found that the existence of capillary pressure will change the phase envelopes. Positive capillary pressure reduces the dew point and bubble point temperatures under the same pressure condition, while the negative capillary pressure increases the dew point and bubble point temperatures. In addition, the change of contact angle and pore radius will affect the phase envelope. The effect of the pore radius on the phase envelope is insignificant when the radius is very large. These results may become reference for future research and study. Keywords: Phase Behavior; Particle Swarm Optimization; Capillary Pressure; Reservoir Fluids; Phase Equilibrium; Phase Envelope.

  20. Phase Behaviors of Reservoir Fluids with Capillary Eff ect Using Particle Swarm Optimization

    KAUST Repository

    Ma, Zhiwei

    2013-01-01

    The study of phase behavior is important for the oil and gas industry. Many approaches have been proposed and developed for phase behavior calculation. In this thesis, an alternative method is introduced to study the phase behavior by means of minimization of Helmholtz free energy. For a system at fixed volume, constant temperature and constant number of moles, the Helmholtz free energy reaches minimum at the equilibrium state. Based on this theory, a stochastic method called Particle Swarm Optimization (PSO) algorithm, is implemented to compute the phase diagrams for several pure component and mixture systems. After comparing with experimental and the classical PT-ash calculation, we found the phase diagrams obtained by minimization of the Helmholtz Free Energy approach match the experimental and theoretical diagrams very well. Capillary effect is also considered in this thesis because it has a significant influence on the phase behavior of reservoir fluids. In this part, we focus on computing the phase envelopes, which consists of bubble and dew point lines. Both fixed and calculated capillary pressure from the Young-Laplace equation cases are introduced to study their effects on phase envelopes. We found that the existence of capillary pressure will change the phase envelopes. Positive capillary pressure reduces the dew point and bubble point temperatures under the same pressure condition, while the negative capillary pressure increases the dew point and bubble point temperatures. In addition, the change of contact angle and pore radius will affect the phase envelope. The effect of the pore radius on the phase envelope is insignificant when the radius is very large. These results may become reference for future research and study. Keywords: Phase Behavior; Particle Swarm Optimization; Capillary Pressure; Reservoir Fluids; Phase Equilibrium; Phase Envelope.

  1. Function modification of SR-PSOX by point mutations of basic amino acids

    Directory of Open Access Journals (Sweden)

    Chen Chunxia

    2011-04-01

    Full Text Available Abstract Background Atherosclerosis (AS is a common cardiovascular disease. Transformation of macrophages to form foam cells by internalizing modified low density-lipoprotein (LDL via scavenger receptor (SR is a key pathogenic process in the onset of AS. It has been demonstrated that SR-PSOX functions as either a scavenger receptor for uptake of atherogenic lipoproteins and bacteria or a membrane-anchored chemokine for adhesion of macrophages and T-cells to the endothelium. Therefore, SR-PSOX plays an important role in the development of AS. In this study the key basic amino acids in the chemokine domain of SR-PSOX have been identified for its functions. Results A cell model to study the functions of SR-PSOX was successfully established. Based on the cell model, a series of mutants of human SR-PSOX were constructed by replacing the single basic amino acid residue in the non-conservative region of the chemokine domain (arginine 62, arginine 78, histidine 80, arginine 82, histidine 85, lysine 105, lysine 119, histidine 123 with alanine (designated as R62A, R78A, H80A, R82A, H85A, K105A, K119A and H123A, respectively. Functional studies showed that the mutants with H80A, H85A, and K105A significantly increased the activities of oxLDL uptake and bacterial phagocytosis compared with the wild-type SR-PSOX. In addition, we have also found that mutagenesis of either of those amino acids strongly reduced the adhesive activity of SR-PSOX by using a highly non-overlapping set of basic amino acid residues. Conclusion Our study demonstrates that basic amino acid residues in the non-conservative region of the chemokine domain of SR-PSOX are critical for its functions. Mutation of H80, H85, and K105 is responsible for increasing SR-PSOX binding with oxLDL and bacteria. All the basic amino acids in this region are important in the cells adhesion via SR-PSOX. These findings suggest that mutagenesis of the basic amino acids in the chemokine domain of SR-PSOX may

  2. Theoretical and testing performance of an innovative indirect evaporative chiller

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yi; Xie, Xiaoyun [Department of Building Science and Technology, Tsinghua University, Beijing (China)

    2010-12-15

    An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller

  3. The spatial extent of rainfall events and its relation to precipitation scaling

    NARCIS (Netherlands)

    Lochbihler, K.U.; Lenderink, Geert; Siebesma, A.P.

    2017-01-01

    Observations show that subdaily precipitation extremes increase with dew point temperature at a rate exceeding the Clausius-Clapeyron (CC) relation. The understanding of this so-called super CC scaling is still incomplete, and observations of convective cell properties could provide important

  4. Data set: 31 years of spatially distributed air temperature, humidity, precipitation amount and precipitation phase from a mountain catchment in the rain-snow transition zone

    Science.gov (United States)

    Thirty one years of spatially distributed air temperature, relative humidity, dew point temperature, precipitation amount, and precipitation phase data are presented for the Reynolds Creek Experimental Watershed. The data are spatially distributed over a 10m Lidar-derived digital elevation model at ...

  5. Importance of hydration in exoelectron emission from ceramic BeO

    International Nuclear Information System (INIS)

    Gammage, R.B.; Cheka, J.S.

    1976-01-01

    The influence of the state of hydration on the exoelectron emitting characteristics of BeO ceramic dosimeters for TSEE is very strong and very complex. For dosimetry the most unfavorable characteristics are a ruined TSEE peak shape and loss of intensity; this occurs if atmosphere moisture is allowed to condense onto, and evaporate from, the BeO surface. For unencapsulated dosimeters this occurs when the ambient temperature falls below the dew point. Immersion of irradiated detectors directly into liquid water for a few hours causes fading at a substantial rate, but surprisingly little change in the TSEE peak shape or intensity. The different behaviors with respect to immersion in liquid water and exposure to condensing atmospheric moisture present an enigma. Ceramic BeO TSEE dosimeters can only be used with confidence in atmospheres where below dew point conditions are avoidable, such as inside air conditioned buildings or encapsulated, dry air containers

  6. Future PMP Estimation in Korea under AR5 RCP 8.5 climate change scenarios and its Changes Cause Analysis

    Science.gov (United States)

    Kim, S.; Lee, J.; Okjeong, L.; Bogyeong, C.; Park, M. W.

    2015-12-01

    In this presentation, Korea's probable maximum precipitations (PMPs) which reflects all of the storm data until recently are calculated, and are compared to the existing PMPs which were calculated at 2000. In Korea, abnormal weather phenomena such as typhoon Rusa and Maemi, and the extreme rainfall event occurred on the east coast of the northern region, that can have a significant impact on the PMP estimation, have frequently happened since 2000. After selecting 240 major storm events from 1973 to 2012, new PMPs are proposed with respect to storm areas (25, 100, 225, 400, 900, 2025, 4900, 10000 and 19600 km2) and storm durations (1, 2, 4, 6, 8, 12, 18, 24, 48 and 72 hours) using the Korea hydro-meteorological method. After estimating future PMPs using future rainfall and dew point temperature information under the Korea Meteorological Administration AR5 RCP 8.5, changes in the PMPs under climate change will be investigated by comparison with present and future PMPs. By separating the changes in PMPs under climate change into the changes caused by rainfall and dew point temperature, the relative impact of future rainfall and dew point temperature information under climate change on future PMPs is quantified. This research was supported by a grant 'Development of the Evaluation Technology for Complex Causes of Inundation Vulnerability and the Response Plans in Coastal Urban Areas for Adaptation to Climate Change' [MPSS-NH-2015-77] from the Natural Hazard Mitigation Research Group, Ministry of Public Safety and Security of Korea.

  7. Biodegradation of clofibric acid and identification of its metabolites

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, R. [REQUIMTE/CQFB, Chemistry Department, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); ESTS-IPS, Escola Superior de Tecnologia de Setubal do Instituto Politecnico de Setubal, Rua Vale de Chaves, Campus do IPS, Estefanilha, 2910-761 Setubal (Portugal); Oehmen, A. [REQUIMTE/CQFB, Chemistry Department, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Carvalho, G. [REQUIMTE/CQFB, Chemistry Department, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Instituto de Biologia Experimental e Tecnologica (IBET), Av. da Republica (EAN), 2784-505 Oeiras (Portugal); Noronha, J.P. [REQUIMTE/CQFB, Chemistry Department, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Reis, M.A.M., E-mail: amr@fct.unl.pt [REQUIMTE/CQFB, Chemistry Department, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal)

    2012-11-30

    Graphical abstract: Metabolites produced during clofibric acid biodegradation. Highlights: Black-Right-Pointing-Pointer Clofibric acid is biodegradable. Black-Right-Pointing-Pointer Mainly heterotrophic bacteria degraded the clofibric acid. Black-Right-Pointing-Pointer Metabolites of clofibric acid biodegradation were identified. Black-Right-Pointing-Pointer The metabolic pathway of clofibric acid biodegradation is proposed. - Abstract: Clofibric acid (CLF) is the pharmaceutically active metabolite of lipid regulators clofibrate, etofibrate and etofyllinclofibrate, and it is considered both environmentally persistent and refractory. This work studied the biotransformation of CLF in aerobic sequencing batch reactors (SBRs) with mixed microbial cultures, monitoring the efficiency of biotransformation of CLF and the production of metabolites. The maximum removal achieved was 51% biodegradation (initial CLF concentration = 2 mg L{sup -1}), where adsorption and abiotic removal mechanisms were shown to be negligible, showing that CLF is indeed biodegradable. Tests showed that the observed CLF biodegradation was mainly carried out by heterotrophic bacteria. Three main metabolites were identified, including {alpha}-hydroxyisobutyric acid, lactic acid and 4-chlorophenol. The latter is known to exhibit higher toxicity than the parent compound, but it did not accumulate in the SBRs. {alpha}-Hydroxyisobutyric acid and lactic acid accumulated for a period, where nitrite accumulation may have been responsible for inhibiting their degradation. A metabolic pathway for the biodegradation of CLF is proposed in this study.

  8. The Effect of Deposit Temperature on the Catalytic SO2-to-SO3 Conversion in a Copper Flash Smelting Heat Recovery Boiler

    Science.gov (United States)

    Lehmusto, Juho; Vainio, Emil; Laurén, Tor; Lindgren, Mari

    2018-02-01

    The aim of the work was to study the catalytic role of copper flash smelter deposit in the SO2-to-SO3 conversion. In addition, the effect of process gas temperature at 548 K to 1173 K (275 °C to 900 °C) on the amount of SO3 formed was addressed both in the absence and presence of genuine copper flash smelter deposit. The SO3 conversion rate changed as a function of process gas temperature, peaking at 1023 K (750 °C). A dramatic increase in the SO2-to-SO3 conversion was observed when process dust was present, clearly indicating that process dust catalyzes the SO2-to-SO3 conversion. Based on these results, the catalytic ability of the deposit may lead to sulfuric acid dew point corrosion.

  9. Evaluation of the Cubic-Plus-Association Equation of State for Ternary, Quaternary, and Multicomponent Systems in the Presence of Monoethylene Glycol

    DEFF Research Database (Denmark)

    Tzirakis, Fragkiskos; Karakatsani, Eirini; Kontogeorgis, Georgios

    2016-01-01

    Dew point specifications are of high interest in the natural gas industry. The CPA equation of state (EoS) was previously validated against both water content and phase equilibrium data. Moreover, solid model parameters were estimated for four natural gas main components (methane, ethane, propane...

  10. Trends in the analysis of natural gas by capillary gas chromatography

    NARCIS (Netherlands)

    Cramers, C.A.M.G.; Rossum, van G.J.

    1986-01-01

    The importance of correct determination of physical and chemical properties of natural gas is evident. The calculation of calorific value or hydrocarbon dew point requires detailed analysis as can be provided by gas chromatography. Analysis by gas chromatography is a necessary complement to direct

  11. Every drop counts: Interview with awardee Gabin Koto N'Gobi ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2012-05-11

    May 11, 2012 ... While artificial dew collection methods already exist, Koto N'Gobi ... The good news is that the condenser harvests up to 4L of water per ... “For example, at the Guene primary school, there is no water point for the students.

  12. Application of the CPE-air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Van Hest, J.; Van der Neut, R.P.; Wijnstra, K.P.

    1986-09-01

    Described is an air conditioning system with a special cooling unit, CPE (combined dew point and heat exchanger). The system has been installed for the first time in the Netherlands in a shop in Utrecht. Results of measurements during September 1985 are presented. 7 figs.

  13. End-point sharpness in thermometric titrimetry.

    Science.gov (United States)

    Tyrrell, H J

    1967-07-01

    It is shown that the sharpness of an end-point in a thermometric titration where the simple reaction A + B right harpoon over left harpoon AB takes place, depends on Kc(A') where K is the equilibrium constant for the reaction, and c(A') is the total concentration of the titrand (A) in the reaction mixture. The end-point is sharp if, (i) the enthalpy change in the reaction is not negligible, and (ii) Kc(A') > 10(3). This shows that it should, for example, be possible to titrate 0.1 M acid, pK(A) = 10, using a thennometric end-point. Some aspects of thermometric titrimetry when Kc(A') < 10(3) are also considered.

  14. Studies on the interference of hydrofluoric acid and phosphoric acid in the determination of uranium using Ti(III) reduction method-biamperometry end point

    International Nuclear Information System (INIS)

    Shiny, T.S.; Rajalakshmi, A.; Phal, D.G.; Charyulu, M.M.; Ramakumar, K.L.

    2007-01-01

    Accurate and precise determination of uranium in nuclear materials is necessary for chemical quality control as well as for nuclear material accounting purposes. Different types of uranium samples are received for the measurements. Depending upon the nature of the sample dissolution procedure is selected. Mixed oxide samples of uranium and plutonium, for example, are dissolved in nitric acid containing hydrofluoric acid under IR lamp. The fluoride ions are removed by repeated evaporation of the solution. However, some fluoride ions are left in the solutions depending on the conditions of evaporation. Uranium samples and alloy samples are dissolved in dilute hydrochloric acid. The rate of dissolution depends on concentration of acid. Sometimes a mixture of hydrochloric acid and hydrofluoric acid is used for the dissolution metal alloy samples, which may contain silica. Another method of dissolution of these samples is using a mixture of phosphoric acid and 1% hydrofluoric acid. It is necessary to study the interference of hydrofluoric acid and phosphoric acid on the determination of uranium

  15. The hormonal regulation of purine biosynthesis: control of the inosinic acid branch point

    International Nuclear Information System (INIS)

    Pizzichini, M.; Di Stefano, A.; Marinello, E.; Pompucci, G.

    1986-01-01

    This paper studies the behavior of purine biosynthesis de novo in the levator animal muscle (LAM) of adult rats, before, after castration, and after testosterone administration. The incorporation of C 14-formate into the acid-soluble bases was performed as an index of the overall rate of purine nucleotide synthesis. It is shown that castration reduces the content, the specific activity of total bases and of the single bases in the LAM, indicating an inferior turnover. The increased turnover of guanylic acid, which is always present although not as much as adenylic acid, will favor the sunthesis of RNA in the sexual organs

  16. The boiling point of stratospheric aerosols.

    Science.gov (United States)

    Rosen, J. M.

    1971-01-01

    A photoelectric particle counter was used for the measurement of aerosol boiling points. The operational principle involves raising the temperature of the aerosol by vigorously heating a portion of the intake tube. At or above the boiling point, the particles disintegrate rather quickly, and a noticeable effect on the size distribution and concentration is observed. Stratospheric aerosols appear to have the same volatility as a solution of 75% sulfuric acid. Chemical analysis of the aerosols indicates that there are other substances present, but that the sulfate radical is apparently the major constituent.

  17. Dual-pressure vaporization Kalina cycle for cascade reclaiming heat resource for power generation

    International Nuclear Information System (INIS)

    Guo, Zhanwei; Zhang, Zhi; Chen, Yaping; Wu, Jiafeng; Dong, Cong

    2015-01-01

    Graphical abstract: Schematic of the dual-pressure evaporation Kalina cycle. - Highlights: • Dual-pressure vaporization Kalina cycle for high-grade heat resource is investigated. • It is designed with 2nd evaporation branch for cascade utilization of heat resource. • Work and basic concentrations, dew point temperature of evaporation are optimized. • Power recovery efficiency of proposed cycle is 17% higher than that of Kalina cycle. • Dual-p vaporization Kalina cycle fits reclaiming heat resource higher than 350 °C. - Abstract: To further improve the cycle efficiency with the heat transfer curves between higher than 350 °C heat resource and the evaporating working medium of the Kalina cycle and to reduce the exhaust temperature of heat resource, the dual-pressure vaporization Kalina cycle for cascade utilization of high-to-mid grade heat resource is proposed. The optimization was conducted for parameters in this modified Kalina cycle such as concentrations of work solution and basic solution, evaporation dew point temperature. Under the conditions of inlet temperatures of heat resource and cooling water of respectively 400 °C and 25 °C and the constraints of proper heat transfer pinch point temperature differences, the maximum evaporation pressure not exceeds 20 MPa, the vapour quality at the turbine outlet is greater than 0.85 and the exhaust temperature of heat resource is not lower than 90 °C, the optimum parameters are obtained that the work and basic concentrations are 0.45 and 0.272 respectively, the dew point temperature of evaporation is 300 °C, and the corresponding power recovery efficiency of the dual-pressure vaporization Kalina cycle reaches 27%, which is 17% higher than that of the Kalina cycle with optimum parameters.

  18. Reflective Inserts to Reduce Heat Strain in Body Armor: Tests With and Without Irradiance

    National Research Council Canada - National Science Library

    Cadarette, Bruce S; Santee, William R; Robinson, Scott B; Sawka, Michael N

    2007-01-01

    ... (10 min rest followed by 100 min walking at 1.56 m s 1). All trials were at 40.0 C dry bulb (Tdb), 12.4 C dew point (Tdp), 20% RH, and 1.0 m s 1 wind speed. On 2 d, there was supplementary irradiance...

  19. Sintering method for nuclear fuel pellet

    International Nuclear Information System (INIS)

    Omuta, Hirofumi; Nakabayashi, Shigetoshi.

    1997-01-01

    When sintering a compressed nuclear fuel powder in an atmosphere of a mixed gas comprising hydrogen and nitrogen, steams are added to the mixed gas to suppress the nitrogen content in sintered nuclear fuel pellets. In addition, the content of nitrogen impurities in the nuclear fuel pellets can be controlled by controlling the amount of steams to be added to the mixed gas, namely, by controlling the dew point as an index thereof. If the addition amount of steams to the mixed gas is determined by controlling the dew point as an index, the content of nitrogen impurities in the sintered nuclear fuel pellets can be controlled reliably to a specified value of 0.0075% or less. If ammonolyzed gas is used as the mixed gas, a more economical mixed gas can be obtained than in the case of forming mixed gas by mixing the hydrogen gas and the nitrogen gas. (N.H.)

  20. Leak detection capability in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Azer, N.; Barber, D.H.; Boucher, P.J. [and others

    1997-04-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.

  1. Leak detection capability in CANDU reactors

    International Nuclear Information System (INIS)

    Azer, N.; Barber, D.H.; Boucher, P.J.

    1997-01-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis

  2. Drying tests conducted on Three Mile Island fuel canisters containing simulated debris

    International Nuclear Information System (INIS)

    Palmer, A.J.

    1995-01-01

    Drying tests were conducted on TMI-2 fuel canisters filled with simulated core debris. During these tests, canisters were dried by heating externally by a heating blanket while simultaneously purging the canisters' interior with hot, dry nitrogen. Canister drying was found to be dominated by moisture retention properties of a concrete filler material (LICON) used for geometry control. This material extends the drying process 10 days or more beyond what would be required were it not there. The LICON resides in a nonpurgeable chamber separate from the core debris, and because of this configuration, dew point measurements on the exhaust stream do not provide a good indication of the dew point in the canisters. If the canisters are not dried, but rather just dewatered, 140-240 lb of water (not including the LICON water of hydration) will remain in each canister, approximately 50-110 lb of which is pore water in the LICON and the remainder unbound water

  3. Selection for the best ETS (error, trend, seasonal) model to forecast weather in the Aceh Besar District

    Science.gov (United States)

    Amora Jofipasi, Chesilia; Miftahuddin; Hizir

    2018-05-01

    Weather is a phenomenon that occurs in certain areas that indicate a change in natural activity. Weather can be predicted using data in previous periods over a period. The purpose of this study is to get the best ETS model to predict the weather in Aceh Besar. The ETS model is a time series univariate forecasting method; its use focuses on trend and seasonal components. The data used are air temperature, dew point, sea level pressure, station pressure, visibility, wind speed, and sea surface temperature from January 2006 to December 2016. Based on AIC, AICc and BIC the smallest values obtained the conclusion that the ETS (M, N, A) is used to predict air temperature, and sea surface temperature, ETS (A, N, A) is used to predict dew point, sea level pressure and station pressure, ETS (A, A, N) is used to predict visibility, and ETS (A, N, N) is used to predict wind speed.

  4. No activation of new initiation points for deoxyribonucleic acid replication in BALB/c 3T3 cells transformed by Kirsten sarcoma virus

    International Nuclear Information System (INIS)

    Oppenheim, A.; Horowitz, A.T.

    1981-01-01

    BALB/c 3T3 cells were transformed by Kirsten sarcoma virus, and five clones were isolated in soft agar. Average replicon sizes of the transformed cell lines were stimated by the method of fiber-autoradiography and found to be the same size as the nontransformed 3T3 cells, analyzed in parallel. The results indicate that, unlike simian virus 40 and Epstein-Barr virus, Kirsten sarcoma virus does not activate new initiation points for cellular deoxyribonucleic acid replication in murine sarcome virus-transformed BALB/c 3T3 cells

  5. Fog, cloud, and dew chemistry. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, M.R.

    1989-02-28

    The spatial and temporal variations of fog/cloud chemistry were determined in the San Joaquin Valley, in the Los Angeles Basin, and in the Santa Barbara Channel area using automated fog- and cloudwater collectors that were designed and constructed for the project. A significant correlation was observed between the average nighttime cloud- and fogwater loadings of H/sup +/ and NO/sub 3//sup /minus// and the maximum levels of O/sub 3//sup /minus//. Higher aldehydes, a series of dicarbonyls, and a variety of sulfonic acid salts formed by reaction of S(IV) and aldehydes were quantitatively determined in the droplet phase.

  6. A detailed analysis of the properties of radiolyzed proteinaceous amino acids

    International Nuclear Information System (INIS)

    Franco Cataldo; Pietro Ragni; Susana Iglesias-Groth; Arturo Manchado

    2011-01-01

    The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N γ ) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N γ does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. Such correlation instead does not exist between the N γ parameter and the onset melting points of the amino acids. An explanation of such lack of correlation was given. Furthermore, a general relationship has been found between the amino acids melting point peak measured on pristine samples and the melting point peaks after solid state radiolysis. Such relationship can be used to predict roughly the expected melting point after radiolysis at 3.2 MGy of any given amino acid. The last part of the study was dedicated in the attempt to find a correlation between the N γ parameter and the amount of the amino acids survived the radiolysis R γ as measured by spectropolarimetry (ORD spectroscopy). A general trend was found in the connection between the N γ and R γ parameters but not a very strong correlation. (author)

  7. Moisture content of cereals at harvesting time by comparing microclimate values and standard weather data.

    NARCIS (Netherlands)

    Atzema, A.J.

    1993-01-01

    The moisture content of wheat and barley together with the weather elements were measured at 3 different experimental sites in the Netherlands in 1990-91. The difference in the dew point temperature in the screen[house] and in the field was small. However, the differences between air temperature in

  8. Full scale investigation on aerogel windows exposed to real climatic conditions

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe; Nielsen, Lars Thomsen

    -filling and hard low-emissivity coatings. The energy saving is reached without significant change in the indoor thermal comfort level.Highly insulating glazing types as aerogel glazings and triple-layered low-energy glazings lead to outside surface temperatures on the glazing that often are below the dew point...

  9. New Submersed Chamber for Calibration of Relative Humidity Instruments at HMI/FSB-LPM

    Science.gov (United States)

    Sestan, D.; Zvizdic, D.; Sariri, K.

    2018-02-01

    This paper gives a detailed description of a new chamber designed for calibration of relative humidity (RH) instruments at Laboratory for Process Measurement (HMI/FSB-LPM). To the present time, the calibrations of RH instruments at the HMI/FSB-LPM were done by comparison method using a climatic chamber of large volume and calibrated dew point hygrometer with an additional thermometer. Since 2010, HMI/FSB-LPM in cooperation with Centre for Metrology and Accreditation in Finland (MIKES) developed the two primary dew point generators which cover the dew point temperature range between - 70 {°}C and 60 {°}C. In order to utilize these facilities for calibrations of the RH instruments, the new chamber was designed, manufactured and installed in the existing system, aiming to extend its range and reduce the related calibration uncertainties. The chamber construction allows its use in a thermostatic bath of larger volume as well as in the climatic chambers. In the scope of this paper, performances of the new chamber were tested while it was submersed in a thermostated bath. The chamber can simultaneously accommodate up to three RH sensors. In order to keep the design of the chamber simple, only cylindrical RH sensors detachable from display units can be calibrated. Possible optimizations are also discussed, and improvements in the design proposed. By using the new chamber, HMI/FSB-LPM reduced the expanded calibration uncertainties (level of confidence 95 %, coverage factor k=2) from 0.6 %rh to 0.25 %rh at 30 %rh (23 {°}C), and from 0.8 %rh to 0.53 %rh at 70 %rh (23 {°}C).

  10. Porous structure and surface chemistry of phosphoric acid activated carbon from corncob

    Energy Technology Data Exchange (ETDEWEB)

    Sych, N.V.; Trofymenko, S.I.; Poddubnaya, O.I.; Tsyba, M.M. [Institute for Sorption and Endoecology Problems, National Academy of Sciences of Ukraine, 13 General Naumov St., 03164 Kyiv (Ukraine); Sapsay, V.I.; Klymchuk, D.O. [M.G. Kholodny Institute of Botany, National Academy of Sciences of Ukraine, 2 Tereshchenkivska St., 01601 Kyiv (Ukraine); Puziy, A.M., E-mail: alexander.puziy@ispe.kiev.ua [Institute for Sorption and Endoecology Problems, National Academy of Sciences of Ukraine, 13 General Naumov St., 03164 Kyiv (Ukraine)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Phosphoric acid activation results in formation of carbons with acidic surface groups. Black-Right-Pointing-Pointer Maximum amount of surface groups is introduced at impregnation ratio 1.25. Black-Right-Pointing-Pointer Phosphoric acid activated carbons show high capacity to copper. Black-Right-Pointing-Pointer Phosphoric acid activated carbons are predominantly microporous. Black-Right-Pointing-Pointer Maximum surface area and pore volume achieved at impregnation ratio 1.0. - Abstract: Active carbons have been prepared from corncob using chemical activation with phosphoric acid at 400 Degree-Sign C using varied ratio of impregnation (RI). Porous structure of carbons was characterized by nitrogen adsorption and scanning electron microscopy. Surface chemistry was studied by IR and potentiometric titration method. It has been shown that porosity development was peaked at RI = 1.0 (S{sub BET} = 2081 m{sup 2}/g, V{sub tot} = 1.1 cm{sup 3}/g), while maximum amount of acid surface groups was observed at RI = 1.25. Acid surface groups of phosphoric acid activated carbons from corncob includes phosphate and strongly acidic carboxylic (pK = 2.0-2.6), weakly acidic carboxylic (pK = 4.7-5.0), enol/lactone (pK = 6.7-7.4; 8.8-9.4) and phenol (pK = 10.1-10.7). Corncob derived carbons showed high adsorption capacity to copper, especially at low pH. Maximum adsorption of methylene blue and iodine was observed for carbon with most developed porosity (RI = 1.0).

  11. Satellite-derived vertical profiles of temperature and dew point for mesoscale weather forecast

    Science.gov (United States)

    Masselink, Thomas; Schluessel, P.

    1995-12-01

    Weather forecast-models need spatially high resolutioned vertical profiles of temperature and dewpoint for their initialisation. These profiles can be supplied by a combination of data from the Tiros-N Operational Vertical Sounder (TOVS) and the imaging Advanced Very High Resolution Radiometer (AVHRR) on board the NOAA polar orbiting sate!- lites. In cloudy cases the profiles derived from TOVS data only are of insufficient accuracy. The stanthrd deviations from radiosonde ascents or numerical weather analyses likely exceed 2 K in temperature and 5Kin dewpoint profiles. It will be shown that additional cloud information as retrieved from AVHIRR allows a significant improvement in theaccuracy of vertical profiles. The International TOVS Processing Package (ITPP) is coupled to an algorithm package called AVHRR Processing scheme Over cLouds, Land and Ocean (APOLLO) where parameters like cloud fraction and cloud-top temperature are determined with higher accuracy than obtained from TOVS retrieval alone. Furthermore, a split-window technique is applied to the cloud-free AVHRR imagery in order to derive more accurate surface temperatures than can be obtained from the pure TOVS retrieval. First results of the impact of AVHRR cloud detection on the quality of the profiles are presented. The temperature and humidity profiles of different retrieval approaches are validated against analyses of the European Centre for Medium-Range Weatherforecasts.

  12. Ambazone-lipoic acid salt: Structural and thermal characterization

    Energy Technology Data Exchange (ETDEWEB)

    Kacso, Irina [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath street, 400293 Cluj-Napoca (Romania); Racz, Csaba-Pal; Santa, Szabolcs [Babes-Bolyai' University, Faculty of Chemistry, 11 Arany Janos street, Cluj-Napoca (Romania); Rus, Lucia [' Iuliu Hatieganu' University of Medicine and Pharmacy, Faculty of Pharmacy, 6 Louis Pasteur street, 400349 Cluj-Napoca (Romania); Dadarlat, Dorin; Borodi, Gheorghe [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath street, 400293 Cluj-Napoca (Romania); Bratu, Ioan, E-mail: ibratu@gmail.com [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath street, 400293 Cluj-Napoca (Romania)

    2012-12-20

    Highlights: Black-Right-Pointing-Pointer Salt of Ambazone with lipoic acid obtained by solvent-drop grinding. Black-Right-Pointing-Pointer Ambazone lipoate salt crystallizes in monoclinic system. Black-Right-Pointing-Pointer FTIR data suggest the deprotonation of the lipoic acid. Black-Right-Pointing-Pointer Thermal behaviour different of ambazone salt as compared to the starting compounds. - Abstract: A suitable method for increasing the solubility, dissolution rate and consequently the bioavailability of poor soluble acidic or basic drugs is their salt formation. The aim of this study is to investigate the structural and thermal properties of the compound obtained by solvent drop grinding (SDG) method at room temperature, starting from the 1:1 molar ratios of ambazone (AMB) and {alpha}-lipoic acid (LA). The structural characterization was performed with X-ray powder diffraction (XRPD) and infrared spectroscopy (FTIR). The thermal behaviour of the obtained compound (AMB{center_dot}LA) was investigated by differential scanning calorimetry (DSC) and thermogravimetry (TG). The photopyroelectric calorimetry, in front detection configuration (FPPE), was applied to measure and compare the room temperature values of one dynamic thermal parameter (thermal effusivity) for starting and resulting compounds. Both structural and supporting calorimetric techniques pointed out a salt structure for AMB{center_dot}LA compound as compared to those of the starting materials.

  13. Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

    DEFF Research Database (Denmark)

    Bellemo, Lorenzo; Elmegaard, Brian; Reinholdt, Lars O.

    This paper presents a numerical study of a regenerative indirect evaporative cooler, the so-called Dew Point Cooler (DPC), which is part of a Desiccant Cooling system that may both dehumidify and cool humid air. The DPC model is based on first principles using a 1D finite volume scheme...

  14. Modelling thermal stratification in the North Sea: Application of a 2-D potential energy model

    DEFF Research Database (Denmark)

    Nielsen, Morten Holtegaard; St. John, Michael

    2001-01-01

    is forced with wind, dew point temperature from Ekofisk oilfield in the central North Sea, and tidal current and atmospheric radiation. The model is used to simulate the seasonal cycle of stratification in the central North Sea in the years 1988, 1989 and 1990 and is compared to density profiles...

  15. Liquid oil production from shale gas condensate reservoirs

    Science.gov (United States)

    Sheng, James J.

    2018-04-03

    A process of producing liquid oil from shale gas condensate reservoirs and, more particularly, to increase liquid oil production by huff-n-puff in shale gas condensate reservoirs. The process includes performing a huff-n-puff gas injection mode and flowing the bottom-hole pressure lower than the dew point pressure.

  16. Improvement of thermal exchange between feedstock and effluent in a hydrocarbon processing unit under hydrogen atmosphere by partial recycling of the product

    Energy Technology Data Exchange (ETDEWEB)

    Orieux, A.

    1990-01-19

    Heat exchange is improved in light naphta hydroisomerization and catalytic reforming by recirculation of a part of the product in the thermal exchange zone at a temperature higher than the dew point of the effluent under hydrogen atmosphere and preferentially as a temperature lower than the temperature of the recycled product.

  17. Influência do orvalho e volume de calda de aplicação na eficácia do glyphosate na dessecação de Brachiaria plantaginea Influence of dew and spray volume on the efficacy of glyphosate for Brachiaria plantaginea burndown

    Directory of Open Access Journals (Sweden)

    E.S. Roman

    2004-09-01

    Full Text Available A eficácia de herbicidas é influenciada por diversos fatores que afetam a absorção e a translocação desses compostos na planta. A absorção de herbicidas pelas plantas, por exemplo, é influenciada, tanto física como biologicamente, pela temperatura e pela umidade relativa do ar dentro do dossel. Com a diminuição da umidade relativa do ar e/ou com o aumento da temperatura, as gotas da pulverização secam mais rapidamente e a absorção do produto diminui, ou até mesmo cessa, afetando o desempenho biológico. Com base nessa premissa, o presente estudo teve como objetivo examinar a influência do orvalho e do volume de calda de aplicação na eficiência de doses de glyphosate para o controle de Brachiaria plantaginea. Foram observadas interações significativas entre volume de calda, orvalho e dose de glyphosate. O volume mais baixo (100 L ha-1 resultou em melhor controle da espécie, especialmente quando o herbicida foi usado na menor dose (90 g ha-1. A presença de orvalho nas folhas causou reduções na atividade do produto, especialmente quando aplicado na menor dose e combinado com maior volume de calda.The efficacy of herbicides is influenced by several factors affecting the absorption and translocation of these compounds in the plant. Herbicide plant absorption, for example, is both physically and biologically influenced by temperature and air relative humidity in the plant canopy. With the reduction in relative air humidity and/or increase in temperature, the spray droplets dry more rapidly and the absorption of the herbicide decreases or even stops, affecting the biological performance. Based on that, this research aimed to study the influence of dew and spray volume on the efficacy of glyphosate rates in the control of B. plantaginea. There were significant interactions among volume of water, dew and rate of glyphosate. The lower the water volume, the more effective the glyphosate activity was, especially when applied at

  18. Vapor-liquid equilibria for nitric acid-water and plutonium nitrate-nitric acid-water solutions

    International Nuclear Information System (INIS)

    Maimoni, A.

    1980-01-01

    The liquid-vapor equilibrium data for nitric acid and nitric acid-plutnonium nitrate-water solutions were examined to develop correlations covering the range of conditions encountered in nuclear fuel reprocessing. The scanty available data for plutonium nitrate solutions are of poor quality but allow an order of magnitude estimate to be made. A formal thermodynamic analysis was attempted initially but was not successful due to the poor quality of the data as well as the complex chemical equilibria involved in the nitric acid and in the plutonium nitrate solutions. Thus, while there was no difficulty in correlating activity coefficients for nitric acid solutions over relatively narrow temperature ranges, attempts to extend the correlations over the range 25 0 C to the boiling point were not successful. The available data were then analyzed using empirical correlations from which normal boiling points and relative volatilities can be obtained over the concentration ranges 0 to 700 g/l Pu, 0 to 13 M nitric acid. Activity coefficients are required, however, if estimates of individual component vapor pressures are needed. The required ternary activity coefficients can be approximated from the correlations

  19. Experimental Determination and Modeling of the Phase Behavior for the Selective Oxidation of Benzyl Alcohol in Supercritical CO2

    DEFF Research Database (Denmark)

    Tsivintzelis, Ioannis; Beier, Matthias Josef; Grunwaldt, Jan-Dierk

    2011-01-01

    In this study the phase behavior of mixtures relevant to the selective catalytic oxidation of benzyl alcohol to benzaldehyde by molecular oxygen in supercritical CO2 is investigated. Initially, the solubility of N2 in benzaldehyde as well as the dew points of CO2–benzyl alcohol–O2 and CO2...

  20. Horns Rev 2 offshore wind farm photo case with wakes observed in 2016

    DEFF Research Database (Denmark)

    Hasager, Charlotte Bay; Nygaard, Nicolai Gayle; Volker, Patrick

    results from atmospheric WRF meso-scale modelling, Park wake model and large eddy simulation wake model are prepared and analysed. At the time of the photos a humid and warm air mass was advected from the southwest over cold sea. The dew-point temperature was such that cold-water advection fog formed...

  1. Diagnostic Measurement at Chimney Operation

    Directory of Open Access Journals (Sweden)

    Radim JANALÍK

    2012-06-01

    Full Text Available The article is focused on the solution of heat penetration through the body of a chimney based on the measurements of output temperatures of flue gases coming out of a chimney and their dew point, in order to determine the minimum flue gas temperature at the bag filter inlet.

  2. Fecal short-chain fatty acids at different time points after ceftriaxone administration in rats

    Directory of Open Access Journals (Sweden)

    Yu. V. Holota

    2017-02-01

    Full Text Available Short-chain fatty acids (SCFAs are major products of the microbial fermentation of dietary fiber in the colon. Recent studies suggest that these products of microbial metabolism in the gut act as signaling molecules, influence host energy homeostasis and play major immunological roles. In the present study, defined the long-term effects of ceftriaxone administration on the fecal SCFAs concentration in Wistar rats. Ceftriaxone (300 mg/kg, i.m. was administered daily for 14 days. Rats were euthanized in 1, 15 and 56 days after ceftriaxone withdrawal. Caecal weight and fecal concentration of SCFAs by gas chromatography were measured. Ceftriaxone administration induced time-dependent rats’ caecal enlargement through accumulation of undigestable substances. In 1 day after ceftriaxone withdrawal, the concentrations of acetic, propionic, butyric acids and total SCFAs were decreased 2.9-, 13.8-, 8.5-, 4.8-fold (P < 0.05, respectively. Concentration of valeric, isovaleric and caproic acids was below the detectable level. That was accompanied by decreased 4.3-fold anaerobic index and increased the relative amount of acetic acid (P < 0.05. In 56 days, concentration of SCFAs was still below control value but higher than in 1 day (except propionic acid. Anaerobic index was lower 1.3-fold (P < 0.05 vs. control. Conclusion: antibiotic therapy induced long-term disturbance in colonic microbiota metabolic activity.

  3. Turkey-hen amino acid composition of brain and eyes

    International Nuclear Information System (INIS)

    Adeyeye, E.I.

    2015-01-01

    The amino acids composition of the brain and eyes of the mature Turkey-hen (Meleagris gallopavo L.), were determined on dry weight basis. Total essential amino acids ranged from 35.1-36.0 g/100 g as 49.5-49.8% of the total amino acids. The amino acid score showed that lysine ranged from 0.76-0.91 (on whole hen.s egg comparison), 0.85-1.03 (on provisional essential amino acid scoring pattern), and 0.81-0.98 (on suggested requirement of the essential amino acid of a preschool child). The predicted protein efficiency ratio was 1.94-2.41, whilst essential amino acid index range was 1.06-1.08 and the calculated isoelectric point range was 3.97-4.18. The correlation coefficient (rxy) was positively high and significant at r = 0.01 for the total amino acids, amino acid scores (on the whole hen.s egg comparisons made) and the isoelectric point. On the whole, the eyes were better in 12/18 or 66.7% parameters of the amino acids than the brain of Turkey-Hen. (author)

  4. The soil-water characteristic curve at low soil-water contents: Relationships with soil specific surface area and texture

    DEFF Research Database (Denmark)

    Resurreccion, A C; Møldrup, Per; Tuller, M

    2011-01-01

    dominate over capillary forces, have also been used to estimate soil specific surface area (SA). In the present study, the dry end of the SWRC was measured with a chilled-mirror dew point psychrometer for 41 Danish soils covering a wide range of clay (CL) and organic carbon (OC) contents. The 41 soils were...

  5. Experimental investigation of carbon monoxide poisoning effect on a PBI/H3PO4 high temperature polymer electrolyte membrane fuel cell

    DEFF Research Database (Denmark)

    Zhou, Fan; Andreasen, Søren Juhl; Kær, Søren Knudsen

    2015-01-01

    humidity level reduced the cell performance loss caused by CO poisoning. When the fuel cell was operated with pure H2, the cell performance was not significantly affect by the change in anode dew point temperature in the range of room temperature and 60 °C. CO2 in anode stream resulted in slight decrease...

  6. The Influences of Water Vapor/Hydrogen Ratio, Gas-Flow Rate and Antimony on the Surface Oxidation of Trip Steels

    International Nuclear Information System (INIS)

    Kwon, You Jong; Zhu, Jing Xi; Sridhar, Seetharaman; Sohn, Il Ryong

    2011-01-01

    In the current paper, we are reporting the results from an investigation of the surface and sub-surface oxidation of a TRIP steel containing 2 wt.% Mn and 0.5 wt.% Al with and without 0.03 wt.% Sb. The oxidizing conditions in the gas were successively varied in terms of the linear gas flow-rate and dew-point, from conditions were gas-phase mass transport limited conditions prevailed, to those were solid state processes became the rate determining conditions. It was found, that at sufficient low oxidizing conditions (defined as flow-rate/dew-point), the metal surfaces were clear of any external oxides, and as the oxidizing conditions were increased, Mn- and Si- oxide nodules formed along with magnetite. As the oxidizing conditions were increased further, a dense magnetite layer was present. The limits of the various regions were experimentally quantified and a proposed hypothesis for their occurrences is presented. No obvious effect of Sb was noted in this micro-structural research of the oxides that results from the various conditions investigated in this study

  7. Measuring method for heat-shrinkage of fuel pellet

    International Nuclear Information System (INIS)

    Komono, Akira; Ishizaki, Jin; Inaki, Kiyohiro.

    1997-01-01

    The present invention concerns a method of determining an amount of heat-shrinkage of UR 2 pellets containing gadolinium oxide (Gd 2 O 2 ) based on the difference of the density thereof before and after heating. In a heat shrinkage test of UO 2 pellets containing from 1.0 to 15.0% by weight of gadolinium oxide, the amount of heat-shrinkage is measured under the condition of heat-retaining temperature: from 1700 to 1750degC, temperature elevation time and lowering time: from 90 to 120mins, heat-retaining time: 24hours, inert gas atmosphere, gas pressure: 0.35kg/cm 2 and gas dew point: from -55 to 40degC without changing O/M. This invention has a feature in the use of the inert gas and the elevation of the dew point of the gas. Then, oxygen dissociation phenomenon from crystal lattices of the fuel pellets is suppressed, and normal densification value is shown. Then, fuel pellets of good quality with less fluctuation of the heat-shrinkage can be obtained. (N.H.)

  8. Effect of Annealed Oxides on the Formation of Inhibition Layer During Hot-Dip Galvanizing of 590Mpa Trip Steel

    International Nuclear Information System (INIS)

    Kim, Seong Hwan; Huh, Joo Youl; Lee, Suk Kyu; Park, Rho Bum; Kim, Jong Sang

    2011-01-01

    The selective surface oxidation of a transformation-induced-plasticity (TRIP) steel containing 1.6 wt.% Mn and 1.5 wt.% Si during annealing at 800 .deg. C was investigated for its influence on the formation of an inhibition layer during hot-dip galvanizing. The selective oxidation of the alloying elements and the oxide morphology were significantly influenced by the annealing atmosphere. The pure N 2 atmosphere with a dew point -40 .deg. C promoted the selective oxidation of Mn as a crystalline Mn 2 SiO 4 phase, whereas the N 2 + 10% H 2 atmosphere with the same dew point -40 .deg. C promoted the selective oxidation of Si as an amorphous Si-rich oxide phase. During hot-dip galvanizing, the Mn 2 SiO 4 phase was reduced more readily by Al in the Zn bath than the Si-rich oxide phase. Consequently, the pure N 2 atmosphere resulted in a higher formation rate of Fe 2 Al 5 particles at the Zn/steel interface and better galvanizability than the N 2 + 10% H 2 atmosphere

  9. Predictions of wet natural gases condensation rates via multi-component and multi-phase simulation of supersonic separators

    International Nuclear Information System (INIS)

    Shooshtari, Seyed Heydar Rajaee; Shahsavand, Akbar

    2014-01-01

    Proper correction of water and heavy hydrocarbon dew points of sweet natural gases is essential from various technical and economical standpoints. Supersonic separators (3S) are proved to be capable of achieving these tasks with maximum reliability and minimal expenses. The majority of the previous articles have focused on the flow behavior of pure fluids across a 3S unit. Multicomponent fluid flow inside 3S accompanied with condensation phenomenon will drastically increase the complexity of the simulation process. We tackle this issue by considering a proper combination of fundamental governing equations and phase equilibrium calculations to predict various operating conditions and composition profiles across two multi-component and multi-phase 3S units. Various Iranian sweet gases are used as real case studies to demonstrate the importance of 3S unit practical applications. Simulation results clearly illustrate the effectiveness of 3S units for faithful dehydration of various natural gases, while successfully controlling its dew point, suitable for any practical applications. Conventional HYSYS simulation software is used to validate the simulation results

  10. Measurement of the total combust gases inside laser fusion pellet with corresponding state method

    International Nuclear Information System (INIS)

    Zhu Zhenghe; Wang Rong; Yang Chuanlu

    2002-01-01

    Based on the reduced parameter, the equations for equilibrium vapor pressure and density of hydrogen isotopes have been derived, which can be used below the critical point of D 2 . It is shown that the calculating results of the saturated vapor density with the corresponding state method is more accurate than that with the dew point method, and that Benedict-Webb-Robin equation is more reasonable than the ideal gas equation for calculating the filling pressure

  11. Observations of speciated atmospheric mercury at three sites in Nevada: Evidence for a free tropospheric source of reactive gaseous mercury

    OpenAIRE

    Weiss-Penzias, Peter; Gustin, Mae Sexauer; Lyman, Seth

    2009-01-01

    Air mercury (Hg) speciation was measured for 11 weeks (June–August 2007) at three sites simultaneously in Nevada, USA. Mean reactive gaseous Hg (RGM) concentrations were elevated at all sites relative to those reported for locations not directly influenced by known point sources. RGM concentrations at all sites displayed a regular diel pattern and were positively correlated with ozone (O3) and negatively correlated with elemental Hg (Hg0) and dew point temperature (Tdp). Superimposed on the d...

  12. Determination of acid–base properties of HCl acid activated palygorskite by Potentiometrie titration

    OpenAIRE

    N. FriniSrasra; E.Srasra

    2008-01-01

    The surface acidity of raw and acid activated palygorskite clay were studied by acid-base potentiometric titration. The Gran plot method was applied for the hydroxide titration and the total surface site (Hs) and the average number of protons reacted per surface site (Z) of palygorskite samples at a given ionic strength were calculated. Acid treatment increases the clay acidity and modifies its surface charge. The point of zero charge value, determined by the common crossing point of Z vs pH ...

  13. Sweating Like a Pig: Physics or Irony?

    Science.gov (United States)

    Bohren, Craig F.

    2016-01-01

    In his interesting and informative book "Is That a Fact?," Joe Schwarcz avers that pigs do not sweat and the saying "sweating like a pig" originates in iron smelting. Oblong pieces of hot iron, with a fancied resemblance to a sow with piglets, cool in sand to the dew point of the surrounding air, and hence water condenses on…

  14. Wind Farm Wake: The 2016 Horns Rev Photo Case

    DEFF Research Database (Denmark)

    Hasager, Charlotte Bay; Nygaard, Nicolai Gayle; Volker, Patrick

    2017-01-01

    are that a humid and warm air mass was advected from the southwest over cold sea and the dew-point temperature was such that cold-water advection fog formed in a shallow layer. The flow was stably stratified and the freestream wind speed was 13 m/s at hub height, which means that most turbines produced at or near...

  15. estimation of precipitable water vapour in nigeria using surface

    African Journals Online (AJOL)

    USER

    For the purpose of this work, Nigeria was divided into four climatic regions and for each region empirical models of the form PWV (T ) and PWV (RH) were found; where T was the surface dew- d d point temperature ... its effect on the atmospheric temperature and .... making contact with the coastal land, the clouds will then ...

  16. 40 CFR 92.110 - Weighing chamber and micro-balance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Weighing chamber and micro-balance. 92... Weighing chamber and micro-balance. (a) Ambient conditions—(1) Temperature. The temperature of the chamber... shall be 45±8 percent during all filter conditioning and weighing. The dew point shall be 6.4 to 12.4 °C...

  17. 49 CFR 180.209 - Requirements for requalification of specification cylinders.

    Science.gov (United States)

    2010-10-01

    ... industrial gas service. Requalification and Inspection of DOT-3AL Cylinders Made of Aluminum Alloy 6351-T6... corroding components; permitted mixtures of these gases (see § 173.301(d) of this subchapter); and permitted mixtures of these gases with up to 30 percent by volume of carbon dioxide, provided the gas has a dew point...

  18. Atmospheric precipitable water in Jos, Nigeria | Utah | Nigerian ...

    African Journals Online (AJOL)

    ... the atmosphere of Jos in the month of August has a value of 4.44±0.47cm, while the minimum of 1.54±0.47cm was found in the month of February. The regression models have been presented and discussed. Keywords: Precipitable water vapour, dew-point temperature, relative humidity. Nigerian Journal of Physics Vol.

  19. A modified two-point titration method for the determination of volatile fatty acids in anaerobic systems.

    Science.gov (United States)

    Mu, Zhe-Xuan; He, Chuan-Shu; Jiang, Jian-Kai; Zhang, Jie; Yang, Hou-Yun; Mu, Yang

    2018-04-10

    The volatile fatty acids (VFA) concentration plays important roles in the rapid start-up and stable operation of anaerobic reactors. It's essential to develop a simple and accurate method to monitor the VFA concentration in the anaerobic systems. In present work, a modified two-point titration method was developed to determine the VFA concentration. The results show that VFA concentration in standard solutions estimated by the titration method coincided well with that measured by gas chromatograph, where all relative errors were lower than 5.5%. Compared with the phosphate, ammonium and sulfide subsystems, the effect of bicarbonate on the accuracy of the developed method was relatively significant. When the bicarbonate concentration varied from 0 to 8 mmol/L, the relative errors increased from 1.2% to 30% for VFA concentration at 1 mmol/L, but were within 2.0% for that at 5 mmol/L. In addition, the VFA composition affected the accuracy of the titration method to some extent. This developed titration method was further proved to be effective with practical effluents from a lab-scale anaerobic reactor under organic shock loadings and an unstable full-scale anaerobic reactor. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Salicylic acid induces apoptosis in colon carcinoma cells grown in-vitro: Influence of oxygen and salicylic acid concentration

    Energy Technology Data Exchange (ETDEWEB)

    Zitta, Karina; Meybohm, Patrick; Bein, Berthold; Huang, Ying; Heinrich, Christin; Scholz, Jens; Steinfath, Markus; Albrecht, Martin, E-mail: Albrecht@anaesthesie.uni-kiel.de

    2012-04-15

    In solid tumors the hypoxic environment can promote tumor progression and resistance to therapy. Recently, acetylsalicylic acid a major component of analgesic drugs and its metabolite salicylic acid (SA) have been shown to reduce the risk of colon cancer, but the mechanisms of action remain still unclear. Here we elucidate the effects of physiologically relevant concentrations of SA on colon carcinoma cells (CaCo-2) grown under normoxic and hypoxic conditions. Western blotting, caspase-3/7 apoptosis assays, MTS cell-proliferation assays, LDH cytotoxicity assays and hydrogen peroxide measurements were performed to investigate the effects of 1 and 10 {mu}M SA on CaCo-2 cells grown under normoxic conditions and cells exposed to hypoxia. Under normoxic conditions, SA did not influence cell proliferation or LDH release of CaCo-2 cells. However, caspase-3/7 activity was significantly increased. Under hypoxia, cell proliferation was reduced and LDH release and caspase-3/7 activities were increased. None of these parameters was altered by the addition of SA under hypoxic conditions. Hypoxia increased hydrogen peroxide concentrations 300-fold and SA significantly augmented the release of hydrogen peroxide under normoxic, but not under hypoxic conditions. Phosphorylation of the pro-survival kinases akt and erk1/2 was not changed by SA under hypoxic conditions, whereas under normoxia SA reduced phosphorylation of erk1/2 after 2 hours. We conclude that in colon carcinoma cells effects of SA on apoptosis and cellular signaling are dependent on the availability of oxygen. -- Highlights: Black-Right-Pointing-Pointer Effects of salicylic acid on colon carcinoma cells grown under normoxic and hypoxic conditions Black-Right-Pointing-Pointer Salicylic acid increases caspase-3/7 activity and hydrogen peroxide release under normoxia Black-Right-Pointing-Pointer Salicylic acid decreases pro-survival erk-1/2 phosphorylation under normoxia Black-Right-Pointing-Pointer Salicylic acid does

  1. Measurement of the oxidation of spent fuel between 140/degree/ and 225/degree/C by thermogravimetric analysis

    International Nuclear Information System (INIS)

    Woodley, R.E.; Einziger, R.E.; Buchanan, H.C.

    1988-09-01

    A series of PWR spent fuel samples from Turkey Point Unit 3 have been oxidized at temperatures between 140/degree/ and 225/degree/C in air atmospheres with dew points between 14.5/degree/ and /minus/70/degree/C, using a thermogravimetric analysis system (TGA). Tests lasted between 400 and 2100 hours. At the conclusion of a test, the atmosphere was sampled to determine the release of fission gas during testing, and the fuel samples were analyzed for microstructural changes. It appears that the mechanism for oxidation of spent fuel to U/sub 3/O/sub 7/ takes place in two steps that occur somewhat simultaneously. Oxygen migrates along the grain boundaries, which are oxidized and enlarged. The grains oxidize by the inward progression of a layer of U/sub 4/O/sub 9/ saturated with oxygen. A simplified model of the mechanism, which considers oxygen diffusion through the product layer as the rate-controlling step, yields an activation energy of 27 /plus minus/ 4 kcal/mol. Moisture, between dew points of /minus/70/degree/ to +14.5/degree/C, i.e., water vapor partial pressures varying over four orders of magnitude, had no significant effect on the oxidation rate. 34 refs., 12 figs., 6 tabs

  2. The solubilities of benzene polycarboxylic acids in water

    International Nuclear Information System (INIS)

    Apelblat, Alexander; Manzurola, Emanuel; Abo Balal, Nazmia

    2006-01-01

    The solubilities in water of all benzene polycarboxylic acids are discussed, using data determined in this work (benzoic, terephthalic, trimellitic, trimesic, and pyromellitic acids) and available from the literature (benzoic, phthalic, isophthalic, terephthalic, hemimellitic, trimelitic, trimesic, mellophanic, prehnitic, pyromellitic, benzene-pentacarboxylic and mellitic acids). The apparent molar enthalpies of solution at the saturation point for these benzene polycarboxylic acids were determined from the temperature dependence of the solubilities

  3. Evaluation of optimal reuse system for hydrofluoric acid wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Won, Chan-Hee [Department of Environmental Engineering, Chonbuk National University, 567 Bakje-daero, Deokjin-Gu, Jeonju, Jeollabuk-Do, 561-756 (Korea, Republic of); Choi, Jeongyun [R and D Center, Samsung Engineering Co. Ltd., 415-10 Woncheon-Dong, Youngtong-Gu, Suwon, Gyeonggi-Do, 443-823 (Korea, Republic of); Chung, Jinwook, E-mail: jin-wook.chung@samsung.com [R and D Center, Samsung Engineering Co. Ltd., 415-10 Woncheon-Dong, Youngtong-Gu, Suwon, Gyeonggi-Do, 443-823 (Korea, Republic of)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Coagulation and ion exchange technologies were ineffective in removing fluoride. Black-Right-Pointing-Pointer Polyamide RO was more efficacious than cellulose RO due to its high flux and rejection. Black-Right-Pointing-Pointer Spiral wound RO system was more preferential to disc tube RO system for reusing raw hydrofluoric acid wastewater. Black-Right-Pointing-Pointer Combined coagulation and RO technology can be applied to reuse raw hydrofluoric acid wastewater. - Abstract: The treatment of hydrofluoric acid (HF) wastewater has been an important environmental issue in recent years due to the extensive use of hydrofluoric acid in the chemical and electronics industries, such as semiconductor manufacturers. Coagulation/precipitation and ion exchange technologies have been used to treat HF wastewater, but these conventional methods are ineffective in removing organics, salts, and fluorides, limiting its reuse for water quality and economic feasibility. One promising alternative is reverse osmosis (RO) after lime treatment. Based on pilot-scale experiment using real HF wastewater discharged from semiconductor facility, the spiral wound module equipped with polyamide membranes has shown excellent flux and chemical cleaning cycles. Our results suggest that coagulation/precipitation and spiral wound RO constitute the optimal combination to reuse HF wastewater.

  4. Test and evaluation of a method of utilizing flue gas below the dew point

    Energy Technology Data Exchange (ETDEWEB)

    Wilsdorf, J.; Mueller, R.

    1983-09-01

    Technological possibilities of using power plant waste heat for low temperature heating of buildings or for industrial heat supply are discussed. Waste heat is recovered with a water circulating heat exchanger to a degree of 15%. Diagrams are presented for a hot water supply system at conventional power generators of 600 to 2,500 kW. Heat balances for a small steam generator of 800 kg/h steam capacity are calculated, comparing the energy efficiency with and without low temperature heat recovery systems. Economic benefits, which can be realized with waste heat recovery systems are calculated. 8 references.

  5. Glutamic acid and folic acid production in aerobic and anaerobic probiotics

    Directory of Open Access Journals (Sweden)

    Zohre Taghi Abadi

    2018-03-01

    Full Text Available Introduction:From an industrial application or commercial point of view, glutamic acid is one of the most important amino acids and its microbial production has been reported from some bacteria. Regarding the role of probiotics to modulate human health and the ever-increasing demand of prebiotics in the food industry, in the current study, production of glutamic acid and folic acid from three probiotic bacteria (Bifidobacterium, Bifidobacterium bifidum, Sporolactobacillus was evaluated for the first time. Materials and methods: MRS broth and exclusive media was used for probiotic culture. The glutamic acid was identified using thin-layer chromatography and folic acid production was measured by folate kit. Each bacterium in terms of quality and quantity were measured by high pressure liquid chromatography. Results: Production of glutamic acid confirmed is based on the thin layer chromatography analysis and high pressure liquid chromatography results. In addition, it was observed that all three probiotics produce folic acid. The prevalence of folate in Bifidobacterium was measured as 315 mg/ml that was more than two other bacteria. Discussion and conclusion: To the best of our knowledge, this is the first report of microbial production of glutamic acid and folate from the probiotic bacteria. These beneficial bacteria can be used as a good source for mass production of these valuable compounds.

  6. Micrometeorological data for energy-budget studies near Rogers Spring, Ash Meadows National Wildlife Refuge, Nye County, Nevada, 1994

    International Nuclear Information System (INIS)

    Nichols, W.D.; Rapp, T.R.

    1996-01-01

    The data were collected at two sites near Rogers Spring for use in energy-budget studies beginning in 1994. The data collected at each site included net radiation, air temperature at two heights, dew- point temperature at two heights, windspeed at two heights, soil heat flux, and soil temperature in the interval between the land surface and the buried heat-flux plates

  7. Colloidal 3-Mercaptopropionic Acid Capped Lead Sulfide Quantum Dots in a Low Boiling Point Solvent.

    Science.gov (United States)

    Reinhart, Chase C; Johansson, Erik

    2017-04-26

    Colloidal 3-mercaptopropionic acid (3-MPA) capped lead sulfide quantum dots were prepared in a variety of organic solvents stabilized with a quaternary ammonium halide salt. The stabilized colloids' optical properties were studied through optical absorption and emission spectroscopy and found to be dependent on both the concentration of a new ligand and stabilizer, and sample age. Nanocrystal ligand chemistry was studied through a combination of 1 H NMR and two-dimensional Nuclear Overhauser Effect Spectroscopy (NOESY) which revealed full displacement of the original oleate ligand to form a dynamically exchanging ligand shell. The colloids were studied optically and via NMR as they aged and revealed a quantitative conversion of monomeric 3-mercaptopropionic acid to its dimer, dithiodipropionic acid (dTdPA).

  8. Monolayer arrangement of fatty hydroxystearic acids on graphite: Influence of hydroxyl groups

    Energy Technology Data Exchange (ETDEWEB)

    Medina, S. [Laboratorio de Rayos-X, Centro de Investigación Tecnología e Innovación, de la Universidad de Sevilla (CITIUS), Universidad de Sevilla, Avenida Reina Mercedes, 4B. 41012, Sevilla (Spain); Benítez, J.J.; Castro, M.A. [Instituto de Ciencia de Materiales de Sevilla, Consejo Superior de Investigaciones Científicas-Universidad de Sevilla, Avenida Américo Vespucio, 49. 41092, Sevilla (Spain); Cerrillos, C. [Servicio de Microscopía, Centro de Investigación Tecnología e Innovación, de la Universidad de Sevilla (CITIUS), Universidad de Sevilla, Avenida Reina Mercedes, 4B. 41012, Sevilla (Spain); Millán, C. [Instituto de Ciencia de Materiales de Sevilla, Consejo Superior de Investigaciones Científicas-Universidad de Sevilla, Avenida Américo Vespucio, 49. 41092, Sevilla (Spain); Alba, M.D., E-mail: alba@icmse.csic.es [Instituto de Ciencia de Materiales de Sevilla, Consejo Superior de Investigaciones Científicas-Universidad de Sevilla, Avenida Américo Vespucio, 49. 41092, Sevilla (Spain)

    2013-07-31

    Previous studies have indicated that long-chain linear carboxylic acids form commensurate packed crystalline monolayers on graphite even at temperatures above their melting point. This study examines the effect on the monolayer formation and structure of adding one or more secondary hydroxyl, functional groups to the stearic acid skeleton (namely, 12-hydroxystearic and 9,10-dihydroxystearic acid). Moreover, a comparative study of the monolayer formation on recompressed and monocrystalline graphite has been performed through X-ray diffraction (XRD) and Scanning Tunneling Microscopy (STM), respectively. The Differential Scanning Calorimetry (DSC) and XRD data were used to confirm the formation of solid monolayers and XRD data have provided a detailed structural analysis of the monolayers in good correspondence with obtained STM images. DSC and XRD have demonstrated that, in stearic acid and 12-hydroxystearic acid adsorbed onto graphite, the monolayer melted at a higher temperature than the bulk form of the carboxylic acid. However, no difference was observed between the melting point of the monolayer and the bulk form for 9,10-dihydroxystearic acid adsorbed onto graphite. STM results indicated that all acids on the surface have a rectangular p2 monolayer structure, whose lattice parameters were uniaxially commensurate on the a-axis. This structure does not correlate with the initial structure of the pure compounds after dissolving, but it is conditioned to favor a) hydrogen bond formation between the carboxylic groups and b) formation of hydrogen bonds between secondary hydroxyl groups, if spatially permissible. Therefore, the presence of hydroxyl functional groups affects the secondary structure and behavior of stearic acid in the monolayer. - Highlights: • Hydroxyl functional groups affect structure and behavior of acids in the monolayer. • Acids on the surface have a rectangular p2 monolayer structure. • Lattice parameters of acids are uniaxially

  9. Production of Medium Chain Fatty Acids by Yarrowia lipolytica: Combining Molecular Design and TALEN to Engineer the Fatty Acid Synthase.

    Science.gov (United States)

    Rigouin, Coraline; Gueroult, Marc; Croux, Christian; Dubois, Gwendoline; Borsenberger, Vinciane; Barbe, Sophie; Marty, Alain; Daboussi, Fayza; André, Isabelle; Bordes, Florence

    2017-10-20

    Yarrowia lipolytica is a promising organism for the production of lipids of biotechnological interest and particularly for biofuel. In this study, we engineered the key enzyme involved in lipid biosynthesis, the giant multifunctional fatty acid synthase (FAS), to shorten chain length of the synthesized fatty acids. Taking as starting point that the ketoacyl synthase (KS) domain of Yarrowia lipolytica FAS is directly involved in chain length specificity, we used molecular modeling to investigate molecular recognition of palmitic acid (C16 fatty acid) by the KS. This enabled to point out the key role of an isoleucine residue, I1220, from the fatty acid binding site, which could be targeted by mutagenesis. To address this challenge, TALEN (transcription activator-like effector nucleases)-based genome editing technology was applied for the first time to Yarrowia lipolytica and proved to be very efficient for inducing targeted genome modifications. Among the generated FAS mutants, those having a bulky aromatic amino acid residue in place of the native isoleucine at position 1220 led to a significant increase of myristic acid (C14) production compared to parental wild-type KS. Particularly, the best performing mutant, I1220W, accumulates C14 at a level of 11.6% total fatty acids. Overall, this work illustrates how a combination of molecular modeling and genome-editing technology can offer novel opportunities to rationally engineer complex systems for synthetic biology.

  10. The effect of the atmosphere and the role of pore filling on the sintering of aluminium

    International Nuclear Information System (INIS)

    Schaffer, G.B.; Hall, B.J.; Bonner, S.J.; Huo, S.H.; Sercombe, T.B.

    2006-01-01

    Alloys of Al-3.8Cu-1Mg-0.7Si, Al-4Cu-0.6Si-0.1Mg, Al-4Cu-1.2Mg and Al-1.9Mg-1.9Si were made using air atomised powder and conventional press-and-sinter powder metallurgy techniques. These were sintered under nitrogen with a controlled water content which varied from 3 to 630 ppm (a dew point of -69 to -25 deg. C), nitrogen-5%hydrogen, argon and argon-5%hydrogen, all at atmospheric pressure, or a vacuum of -2 torr. Dry nitrogen is the most efficacious atmosphere. Vacuum is more effective than argon while hydrogen, and thus water, is extremely prejudicial to sintered density. The minimum dew point for optimum sintering is -60 deg. C (10.5 ppm H 2 O). The key feature in the beneficial effect of nitrogen is the formation of aluminium nitride. This reduces the pressure in the pore spaces relative to the external atmosphere, which induces pore filling at grain sizes that are smaller than those required for sintering in inert atmospheres. It is suggested that pore filling is an important densification mechanism during the sintering of aluminium

  11. Compressor Calorimeter Test of R-410A Alternative: R-32/134a Mixture Using a Scroll Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S [ORNL; Sharma, Vishaldeep [ORNL; Abdelaziz, Omar [ORNL

    2014-02-01

    As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of lower-GWP alternative refrigerant R-32 + R-134a mixture, to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-410A and having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10 F to 55 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat, and 65 F suction temperature. A liquid subcooling level of 15 F was maintained for all the test conditions. The tests showed that the discharge temperature of the alternative refrigerant was higher than that of R-410A at all test conditions. Also, the energy efficiency ratio (EER) and cooling capacity of compressor using the alternative refrigerant were slightly lower in comparison to that of R-410A.

  12. Parametric analysis of parameters for electrical-load forecasting using artificial neural networks

    Science.gov (United States)

    Gerber, William J.; Gonzalez, Avelino J.; Georgiopoulos, Michael

    1997-04-01

    Accurate total system electrical load forecasting is a necessary part of resource management for power generation companies. The better the hourly load forecast, the more closely the power generation assets of the company can be configured to minimize the cost. Automating this process is a profitable goal and neural networks should provide an excellent means of doing the automation. However, prior to developing such a system, the optimal set of input parameters must be determined. The approach of this research was to determine what those inputs should be through a parametric study of potentially good inputs. Input parameters tested were ambient temperature, total electrical load, the day of the week, humidity, dew point temperature, daylight savings time, length of daylight, season, forecast light index and forecast wind velocity. For testing, a limited number of temperatures and total electrical loads were used as a basic reference input parameter set. Most parameters showed some forecasting improvement when added individually to the basic parameter set. Significantly, major improvements were exhibited with the day of the week, dew point temperatures, additional temperatures and loads, forecast light index and forecast wind velocity.

  13. Effect of Annealed Oxides on the Formation of Inhibition Layer During Hot-Dip Galvanizing of 590Mpa Trip Steel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Hwan; Huh, Joo Youl [Korea University, Seoul (Korea, Republic of); Lee, Suk Kyu; Park, Rho Bum; Kim, Jong Sang [POSCO Technical Research Laboratories, Gwangyang (Korea, Republic of)

    2011-02-15

    The selective surface oxidation of a transformation-induced-plasticity (TRIP) steel containing 1.6 wt.% Mn and 1.5 wt.% Si during annealing at 800 .deg. C was investigated for its influence on the formation of an inhibition layer during hot-dip galvanizing. The selective oxidation of the alloying elements and the oxide morphology were significantly influenced by the annealing atmosphere. The pure N{sub 2} atmosphere with a dew point -40 .deg. C promoted the selective oxidation of Mn as a crystalline Mn{sub 2}SiO{sub 4} phase, whereas the N{sub 2} + 10% H{sub 2} atmosphere with the same dew point -40 .deg. C promoted the selective oxidation of Si as an amorphous Si-rich oxide phase. During hot-dip galvanizing, the Mn{sub 2}SiO{sub 4} phase was reduced more readily by Al in the Zn bath than the Si-rich oxide phase. Consequently, the pure N{sub 2} atmosphere resulted in a higher formation rate of Fe{sub 2}Al{sub 5} particles at the Zn/steel interface and better galvanizability than the N{sub 2} + 10% H{sub 2} atmosphere.

  14. Selective surface oxidation and segregation upon short term annealing of model alloys and industrial steel grades

    Energy Technology Data Exchange (ETDEWEB)

    Swaminathan, S.

    2007-07-01

    Segregation and selective oxidation phenomena of minor alloying elements during annealing of steel sheets lead to the formation of bare spots after hot-dip galvanizing. This thesis highlights the influence of annealing conditions and the effect of alloying elements on the selective oxidation in model alloys and some industrial steel grades. Model alloys of binary (Fe-2Si, Fe-2Mn, Fe-0.8Cr), ternary (Fe-2Mn-2Si, Fe-2Mn-0.8Cr, Fe-1Mn-0.8Cr, Fe-1Si-0.8Cr, Fe-2Si-0.8Cr) and quarternary (Fe-2Mn-2Si-0.8Cr) systems were studied. In the case of steels, standard grade interstitial free (IF) steels and experimental grade tensile strength 1000 MPa steel were investigated. All specimens were annealed at 820 C in N{sub 2}-5%H{sub 2} gas atmospheres with the wide range of dew points (i.e. -80 to 0 C). The surface chemistry after annealing and its wettability with liquid Zn have been correlated as a function of dew points by simulating the hot-dip galvanizing process at laboratory scale. (orig.)

  15. Advances in thermal control and performance of the MMT M1 mirror

    Science.gov (United States)

    Gibson, J. D.; Williams, G. G.; Callahan, S.; Comisso, B.; Ortiz, R.; Williams, J. T.

    2010-07-01

    Strategies for thermal control of the 6.5-meter diameter borosilicate honeycomb primary (M1) mirror at the MMT Observatory have included: 1) direct control of ventilation system chiller setpoints by the telescope operator, 2) semiautomated control of chiller setpoints, using a fixed offset from the ambient temperature, and 3) most recently, an automated temperature controller for conditioned air. Details of this automated controller, including the integration of multiple chillers, heat exchangers, and temperature/dew point sensors, are presented here. Constraints and sanity checks for thermal control are also discussed, including: 1) mirror and hardware safety, 2) aluminum coating preservation, and 3) optimization of M1 thermal conditions for science acquisition by minimizing both air-to-glass temperature differences, which cause mirror seeing, and internal glass temperature gradients, which cause wavefront errors. Consideration is given to special operating conditions, such as high dew and frost points. Precise temperature control of conditioned ventilation air as delivered to the M1 mirror cell is also discussed. The performance of the new automated controller is assessed and compared to previous control strategies. Finally, suggestions are made for further refinement of the M1 mirror thermal control system and related algorithms.

  16. Effects of process variables in decarburization annealing of Fe-3%Si-0.3%C steel sheet on textures and magnetic properties

    Science.gov (United States)

    Park, Se Min; Koo, Yang Mo; Shim, Byoung Yul; Lee, Dong Nyung

    2017-01-01

    In Fe-3%Si-0.3%C steel sheet, a relatively strong //ND texture can evolve in the surface layer through the α→γ→α phase transformation in relatively low vacuum (4 Pa) for an annealing time of 10 min and at a cooling rate of 20 K/s. Oxidation of the steel sheet surface prevents the evolution of the //ND texture. However, vacuum-annealing under a vacuum pressure of 1.3×10-3 Pa causes decarburization of the steel sheet, which suppresses oxidation of the steel sheet surface, and subsequent annealing in wet hydrogen of 363 K in dew points causes a columnar grain structure with the //ND texture. After the two-step-annealing (the vacuum annealing under a vacuum pressure of 1.3×10-3 Pa and subsequent decarburizing annealing in wet hydrogen of 363 K in dew points), the decarburized steel sheet exhibits good soft magnetic properties in NO with 3%Si, W15/50 (core loss at 1.5T and 50 Hz) = 2.47 W/kg and B50 (magnetic flux density at 5000 A/m) = 1.71 T.

  17. The effects of meteorological factors on the occurrence of Ganoderma sp. spores in the air

    Science.gov (United States)

    Grinn-Gofroń, Agnieszka; Strzelczak, Agnieszka

    2011-03-01

    Ganoderma sp. is an airborne fungal spore type known to trigger respiratory allergy symptoms in sensitive patients. Aiming to reduce the risk for allergic individuals, we analysed fungal spore circulation in Szczecin, Poland, and its dependence on meteorological conditions. Statistical models for the airborne spore concentrations of Ganoderma sp.—one of the most abundant fungal taxa in the area—were developed. Aerobiological sampling was conducted over 2004-2008 using a volumetric Lanzoni trap. Simultaneously, the following meteorological parameters were recorded: daily level of precipitation, maximum and average wind speed, relative humidity and maximum, minimum, average and dew point temperatures. These data were used as the explaining variables. Due to the non-linearity and non-normality of the data set, the applied modelling techniques were artificial neural networks (ANN) and mutlivariate regression trees (MRT). The obtained classification and MRT models predicted threshold conditions above which Ganoderma sp. appeared in the air. It turned out that dew point temperature was the main factor influencing the presence or absence of Ganoderma sp. spores. Further analysis of spore seasons revealed that the airborne fungal spore concentration depended only slightly on meteorological factors.

  18. Effect of phenols and carboxylic acids on photochromism of 1-alkyl-2-(arylazo)imidazoles

    Energy Technology Data Exchange (ETDEWEB)

    Gayen, Pallab [Inorganic Chemistry Section, Department of Chemistry, Jadavpur University, Kolkata 700032 (India); Sinha, Chittaranjan, E-mail: c_r_sinha@yahoo.com [Inorganic Chemistry Section, Department of Chemistry, Jadavpur University, Kolkata 700032 (India)

    2012-09-15

    Light irradiated trans-to-cis isomerization of 1-alkyl-2-(arylazo)imidazole in the presence of phenol, catechol, benzoic acid and salicylic acid (called co-factors) has been studied in this work. The rate of trans{yields}cis photoisomerization is decreased in the presence of co-factor in the medium and is dependent on the concentration of active quotient about photochrome. The decrease in rate follows catechol>benzoic acid>phenol>salicylic acid. This trend is due to the effects of dissociation ability of -O-H/-COOH, intermolecular association of the molecules etc. The reverse change, cis-to-trans, is very slow in light irradiation and has been carried out by a thermal process in the dark. The quantum yield of isomerization follows the same sequence of effects of co-factors. - Highlights: Black-Right-Pointing-Pointer Photoisomerisation of 1-alkyl-2-(arylazo)imidazoles, trans-to-cis, is described in this work. Black-Right-Pointing-Pointer The process is sensitive to the environment of the photochrome and the solution. Black-Right-Pointing-Pointer The rate of photoisomerization decreases as catechol>benzoic acid>phenol>salicylic acid. Black-Right-Pointing-Pointer The reverse isomerization, cis-to-trans is very slow with light and has been carried out with heat. Black-Right-Pointing-Pointer The activation energy is less than these values when carried out in fresh solution only.

  19. Acrylique acid grafted polyolefines. Thermoadhesive applications

    International Nuclear Information System (INIS)

    Guimon, Claude

    1979-01-01

    Radiochemical grafting of polyolefines by peroxidation has been industrialized in France for about 10 years by irradiation of these polymers with an electron accelerator and then treated by acrylic acid. Products obtained show a high adhesivity on metallic surfaces above their melting point. The main application of acrylic acid grafted high density polyethylene is composite film with aluminum foil for thermosealing of plastic bottle caps of sterilized milk. Acrylic acid grafted polypropylene is used in suspension in a volatile liquid for aluminum foil coating satisfying food packaging regulations [fr

  20. The synthesis of poly(vinylphosphonic acid-co-methacrylic acid) microbeads by suspension polymerization and the characterization of their indium adsorption properties

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Noh-Seok; Baek, Youngmin [Department of Applied Chemistry and Biological Engineering, Chungnam National University, 79 Daehangno, Yuseong-gu, Daejeon 305-764 (Korea, Republic of); Hwang, Taek Sung, E-mail: tshwang@cnu.ac.kr [Department of Applied Chemistry and Biological Engineering, Chungnam National University, 79 Daehangno, Yuseong-gu, Daejeon 305-764 (Korea, Republic of)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer Microbeads were synthesized by suspension polymerization based on VPA, MAA and PEGDA. Black-Right-Pointing-Pointer The best preparation condition was determined from the yield, water uptake and IEC. Black-Right-Pointing-Pointer The adsorption isotherm of indium was fit to the Langmuir and Freundlich models. - Abstract: Poly(vinylphosphonic acid-co-methacrylic acid) microbeads were synthesized by suspension polymerization, and their indium adsorption properties were investigated. The obtained microbeads were characterized by Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The microbeads were wrinkled spheres, irrespective of the components, and their sizes ranged from 100 to 200 {mu}m. The microbeads were thermally stable up to 260 Degree-Sign C. As the vinylphosphonic acid (VPA) content was increased, the synthetic yields and ion-exchange capacities decreased and the water uptakes increased. The optimum synthetic yield, ion-exchange capacity and water uptake were obtained at a 0.5 mol ratio of VPA. In addition, the maximum adsorption predicted by the Langmuir adsorption isotherm model was greatest at a 0.5 mol ratio of VPA.

  1. Bubble point pressures of the selected model system for CatLiq® bio-oil process

    DEFF Research Database (Denmark)

    Toor, Saqib Sohail; Rosendahl, Lasse; Baig, Muhammad Noman

    2010-01-01

    . In this work, the bubble point pressures of a selected model mixture (CO2 + H2O + Ethanol + Acetic acid + Octanoic acid) were measured to investigate the phase boundaries of the CatLiq® process. The bubble points were measured in the JEFRI-DBR high pressure PVT phase behavior system. The experimental results......The CatLiq® process is a second generation catalytic liquefaction process for the production of bio-oil from WDGS (Wet Distillers Grains with Solubles) at subcritical conditions (280-350 oC and 225-250 bar) in the presence of a homogeneous alkaline and a heterogeneous Zirconia catalyst...

  2. Physical Processes in Coastal Stratocumulus Clouds from Aircraft Measurements During UPPEF 2012

    Science.gov (United States)

    2013-09-01

    pressure, dew point, water vapor, absolute humidity, and carbon dioxide concentration. There were various upward and downward looking pyranometers ...Meteorological parameters IR Temperature -50 to +20 °C Up-looking modified Kipp & Zonen CM-22 pyranometer (CIRPAS/NRL) Meteorological parameters Down...welling Solar Irradiance 0-1400 W m -2 Down-looking modified Kipp & Zonen CM-22 pyranometer (CIRPAS/NRL) Meteorological parameters Up-welling Solar

  3. Modelling the phase equilibria of multicomponent mixtures containing CO2, alkanes, water, and/or alcohols using the quadrupolar CPA equation of state

    DEFF Research Database (Denmark)

    Bjørner, Martin Gamel; Kontogeorgis, Georgios

    2016-01-01

    In this work, a quadrupolar cubic plus association (qCPA) equation of state is evaluated for its ability to predict the phase equilibria of multicomponent mixtures containing CO2 and alkanes, alcohols, and/or water. A single binary interaction parameter is employed in qCPA for all binary combinat...... CPA yields the best results of all the models for the prediction of dew point pressures....

  4. AgMIP wheat pilot data 4 release

    OpenAIRE

    Asseng, S.; Ewert, F.; Martre, P.; Supit, I.; Wolf, J.

    2015-01-01

    The data set includes a current representative management treatment from detailed, quality-tested sentinel field experiments with wheat from four contrasting environments including Australia, The Netherlands, India and Argentina. Measurements include local daily climate data (solar radiation, maximum and minimum temperature, precipitation, surface wind, dew point temperature, relative humidity, and vapor pressure), soil characteristics, frequent growth, nitrogen in crop and soil, crop and soi...

  5. Molecular polarization potential maps of the nucleic acid bases

    International Nuclear Information System (INIS)

    Alkorta, I.; Perez, J.J.

    1996-01-01

    Ab initio calculations at the SCF level were carried out to compute the polarization potential map NM of the nucleic acid bases: cytosine, thymine, uracil, adedine, and guanine. For this purpose, the Dunning's 9s5p basis set contracted to a split-valence, was selected to perform the calculations. The molecular polarization potential (MPP) at each point was evaluated by the difference between the interaction energy of the molecule with a unit point charge and the molecular electrostatic potential (MEP) at that point. MEPS and MPPS for the different molecules were computed with a density of 5 points/Angstrom 2 on the van der Waals surface of each molecule, defined using the van der Waals radii. Due to the symmetry of the molecules, only half the points were computed. The total number of points calculated was 558 for cytosine, 621 for thymine, 526 for uracil, 666 for adenine, and 699 for guanine. The results of these calculations are analyzed in terms of their implications on the molecular interactions between pairs of nucleic acid bases. 23 refs., 5 figs., 1 tab

  6. Methods and strategy for modeling daily global solar radiation with measured meteorological data - A case study in Nanchang station, China

    International Nuclear Information System (INIS)

    Wu, Guofeng; Liu, Yaolin; Wang, Tiejun

    2007-01-01

    Solar radiation is a primary driver for many physical, chemical and biological processes on the earth's surface, and complete and accurate solar radiation data at a specific region are quite indispensable to the solar energy related researches. This study, with Nanchang station, China, as a case study, aimed to calibrate existing models and develop new models for estimating missing global solar radiation data using commonly measured meteorological data and to propose a strategy for selecting the optimal models under different situations of available meteorological data. Using daily global radiation, sunshine hours, temperature, total precipitation and dew point data covering the years from 1994 to 2005, we calibrated or developed and evaluated seven existing models and two new models. Validation criteria included intercept, slope, coefficient of determination, mean bias error and root mean square error. The best result (R 2 = 0.93) was derived from Chen model 2, which uses sunshine hours and temperature as predictors. The Bahel model, which only uses sunshine hours, was almost as good, explaining 92% of the solar radiation variance. Temperature based models (Bristow and Campbell, Allen, Hargreaves and Chen 1 models) provided less accurate results, of which the best one (R 2 = 0.69) is the Bristow and Campbell model. The temperature based models were improved by adding other variables (daily mean total precipitation and mean dew point). Two such models could explain 77% (Wu model 1) and 80% (Wu model 2) of the solar radiation variance. We, thus, propose a strategy for selecting an optimal method for calculating missing daily values of global solar radiation: (1) when sunshine hour and temperature data are available, use Chen model 2; (2) when only sunshine hour data are available, use Bahel model; (3) when temperature, total precipitation and dew point data are available but not sunshine hours, use Wu model 2; (4) when only temperature and total precipitation are

  7. Mechanism of the hydrogen reduction of molybdenum oxides

    International Nuclear Information System (INIS)

    Schulmeyer, W.V.; Ortner, H.M.

    2001-01-01

    The two stages of the hydrogen reduction of MoO 3 to Mo were investigated in a thermal balance under well defined reaction conditions. Starting with different grain and agglomerate sizes for both stages, the influence of a set of parameters (temperature, local partial pressure of H 2 O, gas flow, etc.) on the reaction progress and the final result were studied in detail. Depending on the set of parameters used, different reaction mechanisms like pseudomorphic transformation or chemical vapor transport (CVT) were observed. Taking into account that grains and agglomerates deviate from a spherical shape and a definite grain size, the extent of reaction is well described by standard theoretical gas-solid-reaction models such as the shrinking core model (SCM) or the crackling core model (CCM). Thermo-gravimetric analysis (TGA), x-ray diffraction (XRD), scanning electron microscopy (SEM), surface area measurements (BET-method) and laser diffraction were used for these studies. Under all conditions, the first stage shows a reaction path MoO 3 → Mo 4 O 11 → MoO 2 via chemical vapor transport (CVT). The reaction extent follows the crackling core model (Park/Levenspiel). Depending on the local partial pressure of H 2 O during reduction, the formed Mo 4 O 11 and MoO 2 exhibit different size distributions and shapes of the grains. The extent of reaction of the second stage develops according to the shrinking core model (Yagi/Kunii). Depending on the local dew point, two different reaction paths can occur: pseudomorphic transformation at low dew points and transformation via chemical vapor transport at high dew points. This paper is an extract from the Ph.D. thesis of W.V. Schulmeyer 'Mechanismen der Wasserstoffreduktion von Molybdaenoxiden', 1998, Darmstadt University of Technology, Institute of Material Science, Department of Chemical Analytics, FRG. It therefor focuses on a phenomenological description of the most important results. (author)

  8. Acid rain information book. Draft final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-12-01

    Acid rain is one of the most widely publicized environmental issues of the day. The potential consequences of increasingly widespread acid rain demand that this phenomenon be carefully evaluated. Reveiw of the literature shows a rapidly growing body of knowledge, but also reveals major gaps in understanding that need to be narrowed. This document discusses major aspects of the acid rain phenomenon, points out areas of uncertainty, and summarizes current and projected research by responsible government agencies and other concerned organizations.

  9. New insight into photo-bromination processes in saline surface waters: The case of salicylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Tamtam, Fatima; Chiron, Serge, E-mail: serge.chiron@msem.univ-montp2.fr

    2012-10-01

    It was shown, through a combination of field and laboratory observations, that salicylic acid can undergo photo-bromination reactions in sunlit saline surface waters. Laboratory-scale experiments revealed that the photochemical yields of 5-bromosalicylic acid and 3,5-dibromosalicylic acid from salicylic acid were always low (in the 4% range at most). However, this might be of concern since these compounds are potential inhibitors of the 20{alpha}-hydroxysteroid dehydrogenase enzyme, with potential implications in endocrine disruption processes. At least two mechanisms were involved simultaneously to account for the photo-generation of brominated substances. The first one might involve the formation of reactive brominated radical species (Br{center_dot}, Br{sub 2}{center_dot}{sup -}) through hydroxyl radical mediated oxidation of bromide ions. These ions reacted more selectively than hydroxyl radicals with electron-rich organic pollutants such as salicylic acid. The second one might involve the formation of hypobromous acid, through a two electron oxidation of bromine ions by peroxynitrite. This reaction was catalyzed by nitrite, since these ions play a crucial role in the formation of nitric oxide upon photolysis. This nitric oxide further reacts with superoxide radical anions to yield peroxynitrite and by ammonium through the formation of N-bromoamines, probably due to the ability of N-bromoamines to promote the aromatic bromination of phenolic compounds. Field measurements revealed the presence of salicylic acid together with 5-bromosalicylic and 3,5-dibromosalicylic acid in a brackish coastal lagoon, thus confirming the environmental significance of the proposed photochemically induced bromination pathways. -- Highlights: Black-Right-Pointing-Pointer Brominated derivatives of salicylic acid were detected in a brackish lagoon. Black-Right-Pointing-Pointer A photochemical pathway was hypothesized to account for bromination of salicylic acid. Black-Right-Pointing

  10. Surface modification of calcium-copper hydroxyapatites using polyaspartic acid

    Energy Technology Data Exchange (ETDEWEB)

    Othmani, Masseoud; Aissa, Abdallah; Bachoua, Hassen [Laboratoire de Physico-Chimie des Materiaux, Faculte des Sciences de Monastir, 5019 Monastir (Tunisia); Debbabi, Mongi, E-mail: m.debbabi@yahoo.fr [Laboratoire de Physico-Chimie des Materiaux, Faculte des Sciences de Monastir, 5019 Monastir (Tunisia)

    2013-01-01

    Highlights: Black-Right-Pointing-Pointer The reaction of polyaspartic acid with calcium hydroxyapatite and mixed calcium-copper hydroxyapatite is tested. Black-Right-Pointing-Pointer Chemical analysis shows that the presence of copper in the apatitic structure increases the reactivity of the apatite surface. Black-Right-Pointing-Pointer X-ray powder analysis shows the conservation of unique crystalline phase of hydroxyapatite after copper incorporation and/or PASP acid reacting. Black-Right-Pointing-Pointer IR spectra show the formation of the formation of organometallic bond M-O-C (M=Ca or Cu) on the apatitic surface. Black-Right-Pointing-Pointer Transmission electron microscopy (TEM) micrographs and atomic force microscopy (AFM) indicated that the texture surface was changed by the grafting. - Abstract: Mixed calcium-copper hydroxyapatite (Ca-CuHAp), with general formula Ca{sub (10-x)}Cu{sub x}(PO{sub 4}){sub 6}(OH){sub 2}, where 0 {<=} x {<=} 0.75 was prepared in aqueous medium in the presence of different concentrations of poly-L-aspartic acid (PASP). XRD, IR, TG-DTA, TEM-EDX, AFM and chemical analyses were used to characterize the structure, morphology and composition of the products. All techniques show the formation of new hybrid compounds Ca-CuHAp-PASP. The presence of the grafting moiety on the apatitic material is more significant with increasing of copper amount and/or organic concentration in the starting solution. These increases lead to the affectation of apatite crystallinity. The IR spectroscopy shows the conservation of (P-OH) band of (HPO{sub 4}){sup 2-} groups, suggesting that PASP acid was interacted only with metallic cations of hydroxyapatite.

  11. Acid Balance, Dietary Acid Load, and Bone Effects—A Controversial Subject

    Directory of Open Access Journals (Sweden)

    Lynda Frassetto

    2018-04-01

    Full Text Available Modern Western diets, with higher contents of animal compared to fruits and vegetable products, have a greater content of acid precursors vs. base precursors, which results in a net acid load to the body. To prevent inexorable accumulation of acid in the body and progressively increasing degrees of metabolic acidosis, the body has multiple systems to buffer and titrate acid, including bone which contains large quantities of alkaline salts of calcium. Both in vitro and in vivo studies in animals and humans suggest that bone base helps neutralize part of the dietary net acid load. This raises the question of whether decades of eating a high acid diet might contribute to the loss of bone mass in osteoporosis. If this idea is true, then additional alkali ingestion in the form of net base-producing foods or alkalinizing salts could potentially prevent this acid-related loss of bone. Presently, data exists that support both the proponents as well as the opponents of this hypothesis. Recent literature reviews have tended to support either one side or the other. Assuming that the data cited by both sides is correct, we suggest a way to reconcile the discordant findings. This overview will first discuss dietary acids and bases and the idea of changes in acid balance with increasing age, then review the evidence for and against the usefulness of alkali therapy as a treatment for osteoporosis, and finally suggest a way of reconciling these two opposing points of view.

  12. Influence of Adsorption and Capillary Pressure on Phase Equilibria Inside Shale Reservoirs

    DEFF Research Database (Denmark)

    Sandoval, Diego R.; Yan, Wei; Michelsen, Michael L.

    2018-01-01

    is moderate in comparison to the that at low pressure and high temperature. The adsorption effects are stronger for the gas bulk phase region, leading to bigger changes in the gas phase composition and the shift of the dew point curve. PVT simulations of two model reservoir fluid systems show significant...... envelope is different. In general, a much shrunk phase envelope with a shifted critical point is observed. The heavier components are preferentially adsorbed in the whole pressure and temperature range studied here. At high pressure and low temperature, the selectivity towards heavier components...

  13. Portable nucleic acid thermocyclers.

    Science.gov (United States)

    Almassian, David R; Cockrell, Lisa M; Nelson, William M

    2013-11-21

    A nucleic acid thermal cycler is considered to be portable if it is under ten pounds, easily carried by one individual, and battery powered. Nucleic acid amplification includes both polymerase chain reaction (e.g. PCR, RT-PCR) and isothermal amplification (e.g. RPA, HDA, LAMP, NASBA, RCA, ICAN, SMART, SDA). There are valuable applications for portable nucleic acid thermocyclers in fields that include clinical diagnostics, biothreat detection, and veterinary testing. A system that is portable allows for the distributed detection of targets at the point of care and a reduction of the time from sample to answer. The designer of a portable nucleic acid thermocycler must carefully consider both thermal control and the detection of amplification. In addition to thermal control and detection, the designer may consider the integration of a sample preparation subsystem with the nucleic acid thermocycler. There are a variety of technologies that can achieve accurate thermal control and the detection of nucleic acid amplification. Important evaluation criteria for each technology include maturity, power requirements, cost, sensitivity, speed, and manufacturability. Ultimately the needs of a particular market will lead to user requirements that drive the decision between available technologies.

  14. Site Specific Probable Maximum Precipitation Estimates and Professional Judgement

    Science.gov (United States)

    Hayes, B. D.; Kao, S. C.; Kanney, J. F.; Quinlan, K. R.; DeNeale, S. T.

    2015-12-01

    State and federal regulatory authorities currently rely upon the US National Weather Service Hydrometeorological Reports (HMRs) to determine probable maximum precipitation (PMP) estimates (i.e., rainfall depths and durations) for estimating flooding hazards for relatively broad regions in the US. PMP estimates for the contributing watersheds upstream of vulnerable facilities are used to estimate riverine flooding hazards while site-specific estimates for small water sheds are appropriate for individual facilities such as nuclear power plants. The HMRs are often criticized due to their limitations on basin size, questionable applicability in regions affected by orographic effects, their lack of consist methods, and generally by their age. HMR-51 for generalized PMP estimates for the United States east of the 105th meridian, was published in 1978 and is sometimes perceived as overly conservative. The US Nuclear Regulatory Commission (NRC), is currently reviewing several flood hazard evaluation reports that rely on site specific PMP estimates that have been commercially developed. As such, NRC has recently investigated key areas of expert judgement via a generic audit and one in-depth site specific review as they relate to identifying and quantifying actual and potential storm moisture sources, determining storm transposition limits, and adjusting available moisture during storm transposition. Though much of the approach reviewed was considered a logical extension of HMRs, two key points of expert judgement stood out for further in-depth review. The first relates primarily to small storms and the use of a heuristic for storm representative dew point adjustment developed for the Electric Power Research Institute by North American Weather Consultants in 1993 in order to harmonize historic storms for which only 12 hour dew point data was available with more recent storms in a single database. The second issue relates to the use of climatological averages for spatially

  15. Tropospheric profiles of wet refractivity and humidity from the combination of remote sensing data sets and measurements on the ground

    Directory of Open Access Journals (Sweden)

    F. Hurter

    2013-11-01

    Full Text Available We reconstruct atmospheric wet refractivity profiles for the western part of Switzerland with a least-squares collocation approach from data sets of (a zenith path delays that are a byproduct of the GPS (global positioning system processing, (b ground meteorological measurements, (c wet refractivity profiles from radio occultations whose tangent points lie within the study area, and (d radiosonde measurements. Wet refractivity is a parameter partly describing the propagation of electromagnetic waves and depends on the atmospheric parameters temperature and water vapour pressure. In addition, we have measurements of a lower V-band microwave radiometer at Payerne. It delivers temperature profiles at high temporal resolution, especially in the range from ground to 3000 m a.g.l., though vertical information content decreases with height. The temperature profiles together with the collocated wet refractivity profiles provide near-continuous dew point temperature or relative humidity profiles at Payerne for the study period from 2009 to 2011. In the validation of the humidity profiles, we adopt a two-step procedure. We first investigate the reconstruction quality of the wet refractivity profiles at the location of Payerne by comparing them to wet refractivity profiles computed from radiosonde profiles available for that location. We also assess the individual contributions of the data sets to the reconstruction quality and demonstrate a clear benefit from the data combination. Secondly, the accuracy of the conversion from wet refractivity to dew point temperature and relative humidity profiles with the radiometer temperature profiles is examined, comparing them also to radiosonde profiles. For the least-squares collocation solution combining GPS and ground meteorological measurements, we achieve the following error figures with respect to the radiosonde reference: maximum median offset of relative refractivity error is −16% and quartiles are 5% to

  16. Radioiodinated fatty acids for cardiological diagnosis

    International Nuclear Information System (INIS)

    Machulla, H.-J.; Knust, E.J.

    1986-01-01

    The development of fatty acids labelled with iodine-123 is reviewed. The variety of methods for producing 123 I and introducing radioiodine into the molecule is discussed and the important points of the biochemical background are recalled with the aim of finding a broad application for 123 I-labelled fatty acids. The results of the pharmacokinetic studies and biochemical analysis are presented as they prove that both 17- 123 I-heptadecanoic acid (IHA) and 15-(rho- 123 I-phenyl)pentadecanoic acid (IPPA) exhibit analogous behaviour to that of the naturally occurring fatty acids. Clinical applications demonstrated two fields of importance: (i) applications solely for imaging the heart and (ii) assessment of myocardial turnover rates of fatty acids for functional diagnosis. Moreover, very recent studies show that the provision of information about prognosis of myocardial diseases and the applied cardiological therapy appear to be possible. (author)

  17. Acid rain information book. Final report

    International Nuclear Information System (INIS)

    1983-05-01

    Acid rain is one of the most widely publicized environmental issues of the day. The potential consequences of widespread acid rain demand that the phenomenon be carefully evaluated. Review of the literature shows a rapidly growing body of knowledge, but also reveals major gaps in understanding that need to be narrowed. This document discusses aspects of the acid rain phenomenon, points out areas of uncertainty and summarizes current and projected research. The report is organized by a logical progression from sources of pollutants affecting acid rain formation to the atmospheric transport and transformation of those pollutants and finally to the deposition of acid rain, the effects of that deposition, and possible mitigative measures and regulatory options. This information is followed by a discussion of uncertainties in the understanding of the acid rain phenomenon and a description of current and proposed research by responsible government agencies and other concerned organizations

  18. effect of non-volatile solute on the freezing point of malonic acid

    African Journals Online (AJOL)

    DR. AMINU

    with melting point range 134 - 135 OC. It is solid at room temperature with ... MATERIALS AND METHODS. Quality Control. All glass ... The curve usually has three important features; the linear variation of temperature with time, the region where the temperature remains constant for a time values and the region where there ...

  19. Fully 3D printed integrated reactor array for point-of-care molecular diagnostics.

    Science.gov (United States)

    Kadimisetty, Karteek; Song, Jinzhao; Doto, Aoife M; Hwang, Young; Peng, Jing; Mauk, Michael G; Bushman, Frederic D; Gross, Robert; Jarvis, Joseph N; Liu, Changchun

    2018-06-30

    Molecular diagnostics that involve nucleic acid amplification tests (NAATs) are crucial for prevention and treatment of infectious diseases. In this study, we developed a simple, inexpensive, disposable, fully 3D printed microfluidic reactor array that is capable of carrying out extraction, concentration and isothermal amplification of nucleic acids in variety of body fluids. The method allows rapid molecular diagnostic tests for infectious diseases at point of care. A simple leak-proof polymerization strategy was developed to integrate flow-through nucleic acid isolation membranes into microfluidic devices, yielding a multifunctional diagnostic platform. Static coating technology was adopted to improve the biocompatibility of our 3D printed device. We demonstrated the suitability of our device for both end-point colorimetric qualitative detection and real-time fluorescence quantitative detection. We applied our diagnostic device to detection of Plasmodium falciparum in plasma samples and Neisseria meningitides in cerebrospinal fluid (CSF) samples by loop-mediated, isothermal amplification (LAMP) within 50 min. The detection limits were 100 fg for P. falciparum and 50 colony-forming unit (CFU) for N. meningitidis per reaction, which are comparable to that of benchtop instruments. This rapid and inexpensive 3D printed device has great potential for point-of-care molecular diagnosis of infectious disease in resource-limited settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Tunneling dynamics of double proton transfer in formic acid and benzoic acid dimers

    Science.gov (United States)

    Smedarchina, Zorka; Fernández-Ramos, Antonio; Siebrand, Willem

    2005-04-01

    Direct dynamics calculations based on instanton techniques are reported of tunneling splittings due to double proton transfer in formic and benzoic acid dimers. The results are used to assign the observed splittings to levels for which the authors of the high-resolution spectra could not provide a definitive assignment. In both cases the splitting is shown to be due mainly to the zero-point level rather than to the vibrationally or electronically excited level whose spectrum was investigated. This leads to zero-point splittings of 375MHz for (DCOOH)2 and 1107MHz for the benzoic acid dimer. Thus, contrary to earlier calculations, it is found that the splitting is considerably larger in the benzoic than in the formic acid dimer. The calculations are extended to solid benzoic acid where the asymmetry of the proton-transfer potential induced by the crystal can be overcome by suitable doping. This has allowed direct measurement of the interactions responsible for double proton transfer, which were found to be much larger than those in the isolated dimer. To account for this observation both static and dynamic effects of the crystal forces on the intradimer hydrogen bonds are included in the calculations. The same methodology, extended to higher temperatures, is used to calculate rate constants for HH, HD, and DD transfers in neat benzoic acid crystals. The results are in good agreement with reported experimental rate constants measured by NMR relaxometry and, if allowance is made for small structural changes induced by doping, with the transfer matrix elements observed in doped crystals. Hence the method used allows a unified description of tunneling splittings in the gas phase and in doped crystals as well as of transfer rates in neat crystals.

  1. A dipstick sensor for coulometric acid-base titrations

    NARCIS (Netherlands)

    Olthuis, Wouter; van der Schoot, B.H.; Chavez, F.; Bergveld, Piet

    1989-01-01

    By performing an acid-base titration by coulometric generation of OH− or H+ ions at an inert electrode in close proximity to the pH-sensitive gate of an ISFET, it is possible to determine the acid or base concentration of a solution using the ISFET as an indicator device for the equivalence point in

  2. Flower extract as an improvised indicator in acid – base titration ...

    African Journals Online (AJOL)

    Different flowers were collected and the extracts were tested for indicator properties in acidic and basic solutions. The results showed different colour changes in alkaline and colourless in acid solutions. When used in acid-base titration, the end points colours and the average titre values obtained matched with that of ...

  3. Acoustic properties of organic acid mixtures in water

    Science.gov (United States)

    Macavei, I.; Petrisor, V.; Auslaender, D.

    1974-01-01

    The variation of the rate of propagation of ultrasounds in organic acid mixtures in water points to structural changes caused by interactions that take place under conditions of thermal agitation, at different acid concentrations. At the same time, a difference is found in the changes in velocity as a function of the length of the carbon chain of the acids in the mixture as a result of their effect on the groups of water molecules associated by hydrogen bonds.

  4. Synergy effect of naphthenic acid corrosion and sulfur corrosion in crude oil distillation unit

    Energy Technology Data Exchange (ETDEWEB)

    Huang, B.S., E-mail: yinwenfeng2010@163.com [College of Materials Science and Engineering, Southwest Petroleum University, Sichuan, Chengdu, 610500 (China); Yin, W.F. [College of Mechatronic Engineering, Southwest Petroleum University, Sichuan, Chengdu, 610500 (China); Sang, D.H. [Sheng Li Construction Group International Engineering Department, Shandong, Dongying, 257000 (China); Jiang, Z.Y. [College of Materials Science and Engineering, Southwest Petroleum University, Sichuan, Chengdu, 610500 (China)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer The corrosion of a carbon-manganese steel and a stainless steel in sulfur and/or naphthenic acid media was investigated. Black-Right-Pointing-Pointer The corrosion rate of the carbon-manganese steel increased with the increase of the acid value and sulfur content. Black-Right-Pointing-Pointer The critical values of the concentration of sulfur and acid for corrosion rate of the stainless steel were ascertained respectively. Black-Right-Pointing-Pointer The stainless steel is superior to the carbon-manganese steel in corrosion resistance because of the presence of stable Cr{sub 5}S{sub 8} phases. - Abstract: The synergy effect of naphthenic acid corrosion and sulfur corrosion at high temperature in crude oil distillation unit was studied using Q235 carbon-manganese steel and 316 stainless steel. The corrosion of Q235 and 316 in corrosion media containing sulfur and/or naphthenic acid at 280 Degree-Sign C was investigated by weight loss, scanning electron microscope (SEM), EDS and X-ray diffractometer (XRD) analysis. The results showed that in corrosion media containing only sulfur, the corrosion rate of Q235 and 316 first increased and then decreased with the increase of sulfur content. In corrosion media containing naphthenic acid and sulfur, with the variations of acid value or sulfur content, the synergy effect of naphthenic acid corrosion and sulfur corrosion has a great influence on the corrosion rate of Q235 and 316. It was indicated that the sulfur accelerated naphthenic acid corrosion below a certain sulfur content but prevented naphthenic acid corrosion above that. The corrosion products on two steels after exposure to corrosion media were investigated. The stable Cr{sub 5}S{sub 8} phases detected in the corrosion products film of 316 were considered as the reason why 316 has greater corrosion resistance to that of Q235.

  5. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. II

    International Nuclear Information System (INIS)

    Harangozo, M.; Jombik, J.; Schiller, P.; Toelgyessy, J.

    1981-01-01

    A method for the determination of citric, tartaric and undecylenic acids based on radiometric titration with 0.1 or 0.05 mole.l -1 NaOH was developed. As an indicator of the end point, radioactive kryptonate of glass was used. Experimental technique, results of determinations as well as other possible applications of the radioactive kryptonate of glass for end point determination in alkalimetric analyses of officinal pharmaceuticals are discussed. (author)

  6. The meteorological measurement system of the Karlsruhe Nuclear Research Center

    International Nuclear Information System (INIS)

    Dilger, H.

    1976-08-01

    The system mainly serves to record the parameters which are important for the diffusion of offgas plume. The system includes 47 instruments in total which are used to measure the wind velocity, the wind direction, the wind vector, the temperature, the dew point, the solar and heat radiation, the precipitations and the atmospheric pressure, most of them mounted at the 200 m high meteorological tower. (orig./HP) [de

  7. EVALUATION OF SOLVENTS EFFICIENCY IN CONDENSATE BANKING REMOVAL

    OpenAIRE

    CORREA, TOMAS; TIAB, DJEBBAR; RESTREPO, DORA PATRICIA

    2009-01-01

    This work describes experimental design and tests performed to simulate gas condensate reservoir conditions below dew point in the laboratory using three different compositions of synthetic gas condensate. Methanol, propanol and methylene chloride are the solvents used to remove the condensate banking and improve the gas effective permeability near to the wellbore. Solvents are injected in Berea sandstone rock with similar petrophysical properties in order to compare the efficiency at removin...

  8. measurements and analysis of some meteorological elements in ...

    African Journals Online (AJOL)

    Measurements of relative humidity, dew point and vapour pressure at Uturu (Lat. 05.33°N and 06.03°N, and long, 07.10°E and 07.29°E) were carried out. The data were collected in a synoptic hour, that is at 3 hours interval starting from 9am to 6pm each day for the months of February, March, and July using whirling ...

  9. Prediction of acid dissociation constants of organic compounds using group contribution methods

    DEFF Research Database (Denmark)

    Zhou, Teng; Jhamb, Spardha; Liang, Xiaodong

    2018-01-01

    data-points with average absolute error of 0.23; (b) a non-linear GC model for organic compounds using 1622 data-points with average absolute error of 1.18; (c) an artificial neural network (ANN) based GC model for the organic compounds with average absolute error of 0.17. For each of the developed......In this paper, group contribution (GC) property models for the estimation of acid dissociation constants (Ka) of organic compounds are presented. Three GC models are developed to predict the negative logarithm of the acid dissociation constant pKa: (a) a linear GC model for amino acids using 180...

  10. Impact of lactic acid bacteria on conjugated linoleic acid content and atherogenic index of butter

    Directory of Open Access Journals (Sweden)

    L Roufegari-Nejad

    2012-11-01

    Full Text Available This is a study aimed to investigate the effect of lactic acid bacteria including Lactobacillus acidophilus and Sterptococcus thermophilus (as thermophilic culture, Lactococcus lactis subsp. lactis, cremoris and diacetylactis, Leuconostoc citrovorum (as mesophilic culture, Lactobacillus acidophilus, Lactobacillus casei, Bifidobacterium lactis and a mixed culture of L.acidophilus, L. casei and B. lactis on fatty acid profile, conjugated linoleic acid (CLA and atherogenic index (AI of butter. Fatty acid analysis with gas chromatography indicated that application of thermophilic and mixed culture decreased the ratio of saturated to unsaturated fatty acid; whereas, the butters made with L. acidophilus had the highest content of CLA. Moreover, AI in the samples prepared with thermophilic cultures was the least. Sensory evaluation of the treatments revealed no significant differences (p> 0/05 in appearance and color. However, the butters prepared with thermophilic and mesophilic cultures had more desirable taste in comparison with the samples made with L. acidophilus, L. casei and B. lactis. From the nutritional point of view, the adverse effect of butter could be diminished via the application of selected lactic acid bacteria.

  11. Uric Acid, Hyperuricemia and Vascular Diseases

    Science.gov (United States)

    Jin, Ming; Yang, Fan; Yang, Irene; Yin, Ying; Luo, Jin Jun; Wang, Hong; Yang, Xiao-Feng

    2011-01-01

    Uric acid is the product of purine metabolism. It is known that hyperuricemia, defined as high levels of blood uric acid, is the major etiological factor of gout. A number of epidemiological reports have increasingly linked hyperuricemia with cardiovascular and neurological diseases. Studies highlighting the pathogenic mechanisms of uric acid point to an inflammatory response as the primary mechanism for inducing gout and possibly contributing to uric acid's vascular effects. Monosodium urate (MSU) crystals induce an inflammatory reaction, which are recognized by Toll-like receptors (TLRs). These TLRs then activate NALP3 inflammasome. MSU also triggers neutrophil activation and further produces immune mediators, which lead to a proinflammatory response. In addition, soluble uric acid can also mediate the generation of free radicals and function as a pro-oxidant. This review summarizes the epidemiological studies of hyperuricemia and cardiovascular disease, takes a brief look at hyperuricemia and its role in neurological diseases, and highlights the studies of the advanced pathological mechanisms of uric acid and inflammation. PMID:22201767

  12. Study on the stability of adrenaline and on the determination of its acidity constants

    Science.gov (United States)

    Corona-Avendaño, S.; Alarcón-Angeles, G.; Rojas-Hernández, A.; Romero-Romo, M. A.; Ramírez-Silva, M. T.

    2005-01-01

    In this work, the results are presented concerning the influence of time on the spectral behaviour of adrenaline (C 9H 13NO 3) (AD) and of the determination of its acidity constants by means of spectrophotometry titrations and point-by-point analysis, using for the latter freshly prepared samples for each analysis at every single pH. As the catecholamines are sensitive to light, all samples were protected against it during the course of the experiments. Each method rendered four acidity constants corresponding each to the four acid protons belonging to the functional groups present in the molecule; for the point-by-point analysis the values found were: log β 1=38.25±0.21 , log β 2=29.65±0.17 , log β 3=21.01±0.14 , log β 4=11.34±0.071 .

  13. The behaviour of tungsten electrodes in a mixture of acetic acid and acetic anhydride

    International Nuclear Information System (INIS)

    Pastor, T.J.; Vajgand, V.H.

    1976-01-01

    Tungsten electrodes have advantageously been used for potentiometric end-point detection in perchloric acid titration of bases in a mixture of acetic acid and acetic anhydride. They have also given good results in biamperometric detection of the equivalence point in continuous coulometric titration of small quantities of bases and acids in the same solvent. Tungsten electrodes in the presence of quinhydrone behave like platinum electrodes, but in biamperometric end-point determination in the absence of quinhydrone it is better to remove the oxide layer from their surface. Some other factors affecting their behaviour have also been studied. Errors in determination do not exceed +-2% even in titration of very small quantities of substances. (author)

  14. ANTISEPTIC SPRAY BASED ON STABILIZED SILVER PARTICLES: AN ANALYSIS OF ANTISEPTIC PROPERTIES AND COMPREHENSIVE COMPARISON

    Directory of Open Access Journals (Sweden)

    Manuilov, A.M.

    2018-04-01

    Full Text Available Introduction. It's known that some antiseptic sprays based on alcohols can provoke the formation of multi-resistant strains of pathogenic microorganisms. In addition, alcoholic antiseptics has a number of restrictions to use, for example, they can't to be used in even the presence of micro-trauma on the skin, their ingression into the body and mucous membranes is unacceptable. Alternative can be natural antiseptics based on colloidal silver or silver nanoparticles, as well as silver in ionic form. However, such antiseptics has low efficacy against the most dangerous strains. Company Modern Biochem Technologies Ltd. announced the development of a portable device that generates a natural and safe antiseptic Dew, based on stabilized silver particles. Antiseptic Dew surpasses the vast majority of antiseptics based on silver, and is not inferior in effectiveness to antiseptics based on alcohols. This work is devoted to testing the declared characteristics of Dew and its comparison with antiseptics based on colloidal silver, silver nanoparticles and isopropyl alcohol. Materials and methods. To test the antiseptic effect of these agents, we used four test strains from the American Type Culture Collection: E. Coli ATCC 25922, Staphylococcus Aureus ATCC 25923, Candida Albicans ATCC 885-653 and Proteus Vulgaris ATCC 4636 with billion concentration of colony forming units in 1 ml (108 – 109 CFU/mL, ln CFU/mL = 19.57 ... 20.72. Sowing and screening of cultures were performed on sterile Petri dishes according to the standard procedure. Antiseptic Dew was prepared by prototype provided by Modern Biochem Technologies. The antiseptics of comparison were purchased in Kharkiv, Ukraine. The treatment of contaminated surfaces was performed using mechanical pump sprayers. In accordance with the internal protocol, 1 ml of antiseptic was sprayed from the distance of 10 cm onto the infected surface. To determine the silver content in the Dew, we were used atomic

  15. On-line Incorporation of Cloud Point Extraction in Flame Atomic Absorption Spectrometric Determination of Silver

    OpenAIRE

    DALALI, Nasser; JAVADI, Nasrin; AGRAWAL, Yadvendra KUMAR

    2008-01-01

    A cloud point extraction method was incorporated into a flow injection system, coupled with flame atomic absorption spectrometry, for determination of trace amounts of silver. The analyte in the aqueous solution was acidified with 0.2 mol L-1 sulfuric acid and complexed with dithizone. The cloud point extraction was performed using the non-ionic surfactant Triton X-114. After obtaining the cloud point, the surfactant-rich phase containing the dithizonate complex was collected in a m...

  16. Detection and formation scenario of citric acid, pyruvic acid, and other possible metabolism precursors in carbonaceous meteorites

    Science.gov (United States)

    Cooper, George; Reed, Chris; Nguyen, Dang; Carter, Malika; Wang, Yi

    2011-01-01

    Carbonaceous meteorites deliver a variety of organic compounds to Earth that may have played a role in the origin and/or evolution of biochemical pathways. Some apparently ancient and critical metabolic processes require several compounds, some of which are relatively labile such as keto acids. Therefore, a prebiotic setting for any such individual process would have required either a continuous distant source for the entire suite of intact precursor molecules and/or an energetic and compact local synthesis, particularly of the more fragile members. To date, compounds such as pyruvic acid, oxaloacetic acid, citric acid, isocitric acid, and α-ketoglutaric acid (all members of the citric acid cycle) have not been identified in extraterrestrial sources or, as a group, as part of a “one pot” suite of compounds synthesized under plausibly prebiotic conditions. We have identified these compounds and others in carbonaceous meteorites and/or as low temperature (laboratory) reaction products of pyruvic acid. In meteorites, we observe many as part of three newly reported classes of compounds: keto acids (pyruvic acid and homologs), hydroxy tricarboxylic acids (citric acid and homologs), and tricarboxylic acids. Laboratory syntheses using 13C-labeled reactants demonstrate that one compound alone, pyruvic acid, can produce several (nonenzymatic) members of the citric acid cycle including oxaloacetic acid. The isotopic composition of some of the meteoritic keto acids points to interstellar or presolar origins, indicating that such compounds might also exist in other planetary systems. PMID:21825143

  17. Simultaneous estimation of mefenamic acid and ethamsylate in tablets

    OpenAIRE

    Garg G; Saraf Swarnlata; Saraf S

    2007-01-01

    The simple spectrophotometric methods for the determination of mefenamic acid and ethamsylate in pharmaceutical formulations have been developed. The methods are based on the additivity of absorbances and the determination of graphical absorbance ratio at two selected wavelengths, one being the isoabsorptive point for the two drugs (301 nm) and the other being the absorption maximum of mefenamic acid (336 nm) and ethamsylate (305 nm). The Beer Lambert′s law is obeyed for mefenamic acid...

  18. Effect of Processing on Physiochemical Properties and Fatty Acid Composition of Fluted Pumpkin (Telfairia occidentails) Seed Oil

    International Nuclear Information System (INIS)

    Alademeyin, J. O.; Arawande, J. O.

    2016-01-01

    This paper reports the physicochemical properties and fatty acid composition of the seed oil extracted from fluted pumpkin (Telfairia occidentalis). The extracted oil was degummed, neutralised and bleached. The oil yield was 42.26±0.20%. The specific gravity (at 25 degree C) of the oil was 0.923±0.003 and the refractive index (at 25 degree C) was 1.475±0.002. Processing of the crude oil resulted in progressive decrease in turbidity, colour, free fatty acid, acid value, peroxide value and saponification value. However, there was increase in smoke point (243.00±0.03 to 253.00±0.03 degree C), flash point (285.00±1.20 to 304.0 1.10 degree C) and fire point (345.001.10 to 358.0 1.55 degree C) as well as iodine value (113.00 to 121.50 g/100 g) and fatty acid composition during the processing of the oil. The fatty acids detected in the oil samples were myristic, palmitic, stearic, oleic, arachidic, behenic, linoleic and linolenic acids. The predominant fatty acid was oleic acid (47.40-47.90%) followed by linoleic acid (26.36-30.44%) while the least fatty acid was linolenic acid (0.01-0.05%). (author)

  19. ruminants by amino acid analysis of the products of

    African Journals Online (AJOL)

    reveals that in all cases histidine is the limiting amino acid for milk production. Comparison of the milk production potential predicted from the duodenal amino acid supply with that predicted from ... also recognized, in ruminants, as'a critical point in the chain .... be used to model the in vivo situation and measurement of.

  20. A synthetic-dynamic method for water solubility measurements in high pressure CO_2 using ATR–FTIR spectroscopy

    International Nuclear Information System (INIS)

    Comak, Gurbuz; Foltran, Stéphanie; Ke, Jie; Pérez, Eduardo; Sánchez-Vicente, Yolanda; George, Michael W.; Poliakoff, Martyn

    2016-01-01

    Highlights: • A synthetic method using ATR–FTIR spectroscopy has been developed to measure the solubility of water in CO_2_. • New data have been obtained for the dew point of the water at 4.05 MPa, 5.05 MPa and 6.03 MPa. • These data fill a gap in the literature and could be of significance for CO_2 transport in pipelines for CCS technology. - Abstract: A new synthetic method for studying phase behaviour is described using Attenuated Total Reflection (ATR) spectroscopy. The method has been developed to provide relevant information on the solubility of water in CO_2. The dew point of water has been determined at three different pressures, viz. (4.05, 5.05 and 6.03) MPa with mole fractions of water between 0.01 and 0.04. The data obtained fill the gap in the literature in these regions of pressures and temperatures and could be of high importance in the context of Carbon Capture and Storage (CCS) technology. Indeed, the presence of water in the captured CO_2 could damage the pipeline used for CO_2 transport. Hence, it is very important to have a fully understanding of the behaviour of the (CO_2 + H_2O) mixtures in wide range of temperature relevant for CCS.