  1. Delayed clearance of serum HBsAg in compensated cirrhosis B

    DEFF Research Database (Denmark)

    Fattovich, G; Giustina, G; Sanchez-Tapias, J

    1998-01-01

    The aim of this study was to evaluate the incidence, prognostic factors and clinical significance of delayed clearance of serum HBsAg in compensated cirrhosis B.......The aim of this study was to evaluate the incidence, prognostic factors and clinical significance of delayed clearance of serum HBsAg in compensated cirrhosis B....

  2. Low serum hyaluronic acid levels associated with spontaneous HBsAg clearance

    NARCIS (Netherlands)

    Harkisoen, S.; Arends, J. E.; van den Hoek, A.; van Erpecum, K. J.; Boland, G. J.; Hoepelman, A. I. M.

    2015-01-01

    Purpose The pathophysiological underlying mechanism of spontaneous HBsAg clearance in hepatitis B virus (HBV) infected patients is largely unknown. However, serum hyaluronic acid (sHA) plays a role in liver fibrosis progression and reversely could serve as a potential biomarker for HBsAg clearance.

  3. ADCC-Mediated CD56DIM NK Cell Responses Are Associated with Early HBsAg Clearance in Acute HBV Infection.

    Science.gov (United States)

    Yu, Wen-Han; Cosgrove, Cormac; Berger, Christoph T; Cheney, Patrick C; Krykbaeva, Marina; Kim, Arthur Y; Lewis-Ximenez, Lia; Lauer, Georg M; Alter, Galit

    2018-01-01

    Hepatitis B virus (HBV) affects up to 400 million people worldwide and accounts for approximately one million deaths per year from liver pathologies. Current treatment regimens are effective in suppressing viremia but usually have to be taken indefinitely, warranting research into new therapeutic approaches. Acute HBV infection in adults almost universally results in resolution of viremia, with the exception of immunocompromised persons, suggesting that the immune response can functionally cure or even eradicate HBV infection. Because immunophenotypic and functional studies have implicated a role for Natural Killer (NK) cells in HBV clearance during acute infection, we hypothesized that a distinct NK-cell profile exists in acute HBV infection that could provide information for the mechanism of HBV clearance. Using multivariate flow cytometry, we evaluated the expression of key activating and inhibitory receptors on NK cells, and their ability to respond to classic target cell lines. Multivariate analysis revealed selective perturbation of the CD56 dim NK-cell subset during acute infection, displaying low levels of NKp46+, NKp30+, CD160+ and CD161+ cells. Intriguingly, the CD56 dim NK-cell profile predicted time to HBV surface antigen (HBsAg) clearance from the blood, and distinct NK-cell profiles predicted early (NKp30, CD94, CD161) and late clearance (KIR3DL1, CD158a, perforin, NKp46). Finally, functional analysis demonstrated that early and late clearance tracked with elevated degranulation (CD107a) or IFNγ production, respectively, in response to ADCC-mediated activation. The cytolytic CD56 dim NK-cell subset is selectively activated in acute HBV infection and displays distinct phenotypic and functional profiles associated with efficient and early control of HBV, implicating antibody-mediated cytolytic NK-cell responses in the early control and functional cure of HBV infection.

  4. Analysis of hepatitis B surface antigen (HBsAg) using high-sensitivity HBsAg assays in hepatitis B virus carriers in whom HBsAg seroclearance was confirmed by conventional assays.

    Science.gov (United States)

    Ozeki, Itaru; Nakajima, Tomoaki; Suii, Hirokazu; Tatsumi, Ryoji; Yamaguchi, Masakatsu; Kimura, Mutsuumi; Arakawa, Tomohiro; Kuwata, Yasuaki; Ohmura, Takumi; Hige, Shuhei; Karino, Yoshiyasu; Toyota, Joji

    2018-02-01

    We investigated the utility of high-sensitivity hepatitis B surface antigen (HBsAg) assays compared with conventional HBsAg assays. Using serum samples from 114 hepatitis B virus (HBV) carriers in whom HBsAg seroclearance was confirmed by conventional HBsAg assays (cut-off value, 0.05 IU/mL), the amount of HBsAg was re-examined by high-sensitivity HBsAg assays (cut-off value, 0.005 IU/mL). Cases negative for HBsAg in both assays were defined as consistent cases, and cases positive for HBsAg in the high-sensitivity HBsAg assay only were defined as discrepant cases. There were 55 (48.2%) discrepant cases, and the range of HBsAg titers determined by high-sensitivity HBsAg assays was 0.005-0.056 IU/mL. Multivariate analysis showed that the presence of nucleos(t)ide analog therapy, liver cirrhosis, and negative anti-HBs contributed to the discrepancies between the two assays. Cumulative anti-HBs positivity rates among discrepant cases were 12.7%, 17.2%, 38.8%, and 43.9% at baseline, 1 year, 3 years, and 5 years, respectively, whereas the corresponding rates among consistent cases were 50.8%, 56.0%, 61.7%, and 68.0%, respectively. Hepatitis B virus DNA negativity rates were 56.4% and 81.4% at baseline, 51.3% and 83.3% at 1 year, and 36.8% and 95.7% at 3 years, among discrepant and consistent cases, respectively. Hepatitis B surface antigen reversion was observed only in discrepant cases. Re-examination by high-sensitivity HBsAg assays revealed that HBsAg was positive in approximately 50% of cases. Cumulative anti-HBs seroconversion rates and HBV-DNA seroclearance rates were lower in these cases, suggesting a population at risk for HBsAg reversion. © 2017 The Japan Society of Hepatology.

  5. An investigation of clinical features of HBsAg and anti-HBs positive patients with chronic hepatitis B

    Directory of Open Access Journals (Sweden)

    SONG Jinyun

    2016-11-01

    sites in S region included P29L, S61L, P62L, I126T/S, Q129N, M133K, F134L, G145R/K, L175S, and L186H. ConclusionThe patients with positive HBsAg and anti-HBs account for a certain proportion in patients with hepatitis B, and the major reason may be variation of viral strains. This situation does not indicate the improvement in disease, and the appearance of anti-HBs may not achieve complete and effective HBsAg clearance. There may be persistent replication of viral DNA, which needs to be taken seriously.

  6. No response to hepatitis B vaccine in infants born to HBsAg(+) mothers is associated to the transplacental transfer of HBsAg.

    Science.gov (United States)

    Wang, Jing; He, Yingli; Jin, Dongfang; Liu, Jinfeng; Zheng, Jie; Yuan, Ningxia; Bai, Yun; Yan, Taotao; Yang, Yuan; Liu, Yong; Zhang, Shulin; Zhao, Yingren; Chen, Tianyan

    2017-08-01

    No or low hepatitis B (HB) vaccine response is more frequent in infants from HBsAg(+) mothers than those from HBsAg(-). Our previous study found temporary positivity of HBsAg in infants from HBsAg(+) mothers. In this study, we hypothesized that HBsAg in infant blunt immune response to standard hepatitis B vaccination. A total of 328 consecutive HBsAg(+) mothers and their offspring were enrolled. Blood samples were taken from mothers and their infants and quantified for HBsAg, anti-HBs titer and HBV DNA load concentration; Placenta samples were collected to stain for HBsAg. First, 6.7% infants (22/328) showed anti-HBs titer lower than 10 mIU/mL after HB vaccination (non-response to HB vaccine). HBsAg(+) newborns showed higher risk of non-response than HBsAg(-) infants (13.0% versus 5.0%, p = 0.016). Infants from high HBsAg titer mothers displayed higher risk of HBsAg positivity at birth than those from low titer mothers (45.3% versus 2.8%, p < 0.001). HBsAg titer in mothers of HBsAg(+) newborns was much higher than mothers of HBsAg(-) newborns (p < 0.001). All those data supported HBsAg can be transferred through placenta. Our hypothesis was further reinforced by immunostaining with specific antibody against HBsAg, a substantial higher prevalence (87.5% versus 30.8%, p = 0.024) and stronger immunostaining (p = 0.008) was demonstrated in HBsAg(+) group comparing with placenta of the HBsAg(-) group. No response to HB vaccine in infants of HBsAg(+) mothers was associated to the transplacental transfer of HBsAg.

  7. Application of a newly developed high-sensitivity HBsAg chemiluminescent enzyme immunoassay for hepatitis B patients with HBsAg seroclearance.

    Science.gov (United States)

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-11-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstrated seroclearance by the Abbott Architect assay. The performance of the Lumipulse HBsAg-HQ assay was compared with that of a quantitative HBsAg detection system (Abbott Architect) and the Roche Cobas TaqMan HBV DNA assay (CTM) (lower limit of detection, 2.1 log copies/ml) using blood serum samples from patients who were determined to be HBsAg seronegative by the Abbott Architect assay. Ten patients had spontaneous HBsAg loss. Of 8 patients treated with nucleotide analogues (NAs), two were HBsAg seronegative after stopping lamivudine therapy and 6 were HBsAg seronegative during entecavir therapy. Eight acute hepatitis B (AH) patients became HBsAg seronegative. Of the 26 patients, 16 were HBsAg positive by the Lumipulse HBsAg-HQ assay but negative by the Abbott Architect assay. The differences between the two assays in terms of detectable HBsAg persisted over the long term in the spontaneous loss group (median, 10 months), the NA-treated group (2.5 months), and the AH group (0.5 months). In 9 patients, the Lumipulse HBsAg-HQ assay detected HBsAg when HBV DNA was negative by the CTM assay. HBsAg was also detected by the Lumipulse HBsAg-HQ assay in 4 patients with an anti-HBs concentration of >10 mIU/ml, 3 of whom had no HBsAg escape mutations. The automatic, highly sensitive HBsAg CLEIA Lumipulse HBsAg-HQ is a convenient and precise assay for HBV monitoring.

  8. Comparison of serum HBsAg quantitation by four immunoassays, and relationships of HBsAg level with HBV replication and HBV genotypes.

    Directory of Open Access Journals (Sweden)

    Edouard Tuaillon

    Full Text Available BACKGROUND: The decline in hepatitis B virus surface antigen (HBsAg may be an early predictor of the viral efficacy of Hepatitis B virus (HBV therapy. The HBsAg levels obtained by different immunoassays now need comparing and the relationships between levels of HBsAg and HBV DNA alongside HBsAg and genotype must be evaluated. METHODOLOGY/PRINCIPAL FINDINGS: HBsAg levels were compared among 80 patients using the Abbott Architect assay, a commercial immunoassay approved for HBsAg detection and quantitation, and three other assays derived from immunoassays approved for HBsAg detection (manufactured by Diasorin, Bio-Rad and Roche. Good correlation was found between the Abbot vs. Diasorin, Bio-Rad and Roche assays with narrow 95% limits of agreement and small mean differences: -0.06 to 0.11, -0.09 log(10 IU/mL; -0.57 to 0.64, -0.04 log(10 IU/mL; -0.09 to 0.45, -0.27 log(10 IU/mL, respectively. These agreements were not affected by genotypes A or D. HBsAg was weakly correlated with HBV DNA, whatever the HBsAg assay used: Abbott, ρ = 0.36 p = 0.001, Diasorin ρ = 0.34, p = 0.002; Bio-Rad ρ = 0.37, p<0.001; or Roche ρ = 0.41, p<0.001. This relationship between levels of HBsAg and HBV DNA seemed to depend on genotypes. Whereas HBsAg (Abbott assay tended to correlate with HBV DNA for genotype A (ρ = 0.44, p = 0.02, no such correlation was significant for genotypes D (ρ = 0.29, p = 0.15. CONCLUSION/SIGNIFICANCE: The quantitation of HBsAg in routine clinical samples is comparable between the reference assay and the adapted assays with acceptable accuracy limits, low levels of variability and minimum discrepancy. While HBsAg quantitation is not affected by HBV genotype, the observed association between levels of HBsAg and HBV DNA seems genotype dependent.

  9. Anti-pre-S responses and viral clearance in chronic hepatitis B virus infection.

    Science.gov (United States)

    Budkowska, A; Dubreuil, P; Poynard, T; Marcellin, P; Loriot, M A; Maillard, P; Pillot, J

    1992-01-01

    Serial sera were collected prospectively during the clinical course of 13 HBsAg carriers with chronic liver disease and analyzed for ALT levels, pre-S1 and pre-S2 antigens and corresponding antibodies and other serological hepatitis B virus markers. In five patients, anti-pre-S1 and anti-pre-S2 antibodies became detectable in multiple serum samples, whereas in eight patients anti-pre-S was never detected or only appeared transiently during the follow-up. The first pattern was associated with normalization of ALT levels and undetectable pre-S antigens and viral DNA by the polymerase chain reaction assay at final follow-up. HBsAg clearance occurred in two of the five patients. The second pattern was one of persistence of HBsAg and pre-S antigens, associated with the presence of serum HBV DNA detectable by spot hybridization or polymerase chain reaction regardless of clinical outcome. These findings demonstrate the occurrence of anti-pre-S antibodies in chronic hepatitis B virus-induced liver disease and associate anti-pre-S appearance with the clearance of hepatitis B virus from serum.

  10. Breaking tolerance in hepatitis B surface antigen (HBsAg) transgenic mice by vaccination with cross-reactive, natural HBsAg variants

    DEFF Research Database (Denmark)

    Schirmbeck, Reinhold; Dikopoulos, Nektarios; Kwissa, Marcin

    2003-01-01

    Processing exogenous hepatitis B surface antigen (HBsAg) of the hepatitis B virus (HBV) generates the K(b)-binding S(208-215) epitope 1; processing endogenous HBsAg generates the K(b)-binding S(190-197) epitope 2. Cross-reactive CD8(+) T cell responses were primed to epitope 1 but not epitope 2...... HBs-tg mice showed reduced antigenemia. Hence, vaccination with natural HBsAg variants from different HBV sero/genotypes can prime cross-reactive, specific CD8(+) T cell immunity that breaks tolerance to HBsAg....

  11. [Clinical evaluation of a novel HBsAg quantitative assay].

    Science.gov (United States)

    Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-07-01

    The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.

  12. Application of a Newly Developed High-Sensitivity HBsAg Chemiluminescent Enzyme Immunoassay for Hepatitis B Patients with HBsAg Seroclearance

    OpenAIRE

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-01-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstr...

  13. GAMBARAN ANTI HBc POSITIF PADA DONOR DARAH DENGAN HbsAG NEGATIF

    Directory of Open Access Journals (Sweden)

    Susila Sastri

    2009-09-01

    Full Text Available AbstrakPemeriksaan HBsAg saja untuk skrining hepatitis B (HBV belum dapat menjamin donor darah bebas dari HBV sehingga darah donor belum memenuhi persyaratan untuk ditransfusikan. Darah donor yang akan ditranfusikan hendaklah memenuhi syarat diantaranya donor tidak pernah menderita HBV. Skrining darah donor terhadap HBV pada PMI hanya dengan uji HBsAg saja dimana HBsAg akan negatif pada stadium HBV tertentu, pada hal donor menderita atau dalam masa penyembuhan HBV. Anti-HBc dapat memberi informasi tentang perjalanan HBV bila digabungkan dengan marker HBV lain dan anti-HBc bertahan lebih lama dalam darah dibandingkan dengan marker lain. Donor darah HBsAg negatif dengan anti-HBc positif dari beberapa penelitian terdahulu masih ada yang mengandung HBV-DNA dan dapat menularkan HBV.Telah dilakukan penelitian terhadap donor darah dengan melakukan uji anti-HBc secara deskriptif terhadap donor darah dengan HBsAg negatif (n=100 pada UTD PMI Cabang Padang secara cross sectional study. Sampel diambil secara proportional random sampling. Darah sampel adalah darah HBsAg negatif dengan VDRL, HVC, HIV  negatif , semuanya diperiksa dengan dengan ELISATujuan penelitian untuk melihat gambaran anti-HBc positif pada donor darah dengan HBsAg negatif dan melihat hubungan antara indeks HBsAg dengan indeks anti-HBc. Pemeriksaan anti-HBc dilakukan dengan ELISA, alat dan reagen keluaran yang sama.Hasil penelitian menunjukkan frekuensi anti-HBc positif pada donor darah dengan HBsAg negatif sebanyak 27%, terutama pada laki-laki berumur antara 20-29 tahun (44,4%. Terdapat korelasi positif antara indeks HBsAg negatif dengan indeks anti-HBc (r = 0,02. Anti-HBc positif banyak ditemukan pada indeks HBsAg negatif 0,21-0,60 (76%.Kesimpulan, darah donor dengan HBsAg negatif yang selama ini dianggap aman untuk transfusi terbukti masih mungkin menularkan HBV dengan ditemukannya anti-HBc yang positif. Karena itu perlu pemeriksaan lanjutan DNA HBV pada donor darah dengan HbsAg

  14. Hepatitis B and C coinfection in a real-life setting: viral interactions and treatment issues.

    Science.gov (United States)

    Papadopoulos, Nikolaos; Papavdi, Maria; Pavlidou, Anna; Konstantinou, Dimitris; Kranidioti, Hariklia; Kontos, George; Koskinas, John; Papatheodoridis, George V; Manolakopoulos, Spilios; Deutsch, Melanie

    2018-01-01

    Only limited data concerning hepatitis B (HBV) and C viruses (HCV) coinfection are available. Direct-acting antivirals (DAAs) may be more effective for HCV clearance than interferon (IFN)-based regimens with a risk of HBV reactivation. We retrospectively enrolled 40 HBV/HCV-coinfected patients to evaluate their clinical profile and treatment outcomes. Chronic dual infection was present in 25/40 (62.5%) patients, acute HCV superinfection in 5/40 (12.5%) patients and acute HBV superinfection in 10/40 (25%). Twenty-five patients (62.5%) were treated: 16/25 (64%) with IFN, 4/25 (16%) with nucleot(s)ide analogs (NUCs) and 5/25 (20%) with DAAs. Of the 16 patients treated with IFN-based therapy, 6 (37.5%) achieved both sustained virological response (SVR) and HBsAg clearance. Of the 4 patients treated with NUCs, one (25%) achieved both SVR and HBsAg clearance. All five patients treated with DAAs (100%) achieved SVR, while one case of HBV reactivation was recorded. Fifteen of the 40 patients (37.5%) did not receive any treatment. Eight of them (53.5%) presented with acute HBV superinfection: spontaneous HCV clearance was recorded in 5/8 (62.5%), while HBsAg clearance occurred in 6/8 (75%). Three of them (20%) presented with acute HCV superinfection; spontaneous HCV clearance was recorded in one of the three (33.5%). The other four patients (26.5%) presented with dual HBV/HCV infection. A significant proportion of patients presented with active HBV replication. Treatment with DAAs seems to be efficacious for HCV eradication. However, clinicians should be aware of HBV reactivation. HBV superinfection may lead to both HBsAg and HCV clearance.

  15. [Comparison of the clinical performance of the ECLusys HBsAg II assay with the Lumipulse f and HISCL 2000-i HBsAg screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-02-01

    We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.

  16. HBsAg level and hepatitis B viral load correlation with focus on pregnancy

    Science.gov (United States)

    Belopolskaya, Maria; Avrutin, Viktor; Firsov, Sergey; Yakovlev, Alexey

    2015-01-01

    Background Viral load measurement is necessary to estimate mother-to-child transmission risk for women with chronic hepatitis B (CHB), however, it is expensive. The present study aimed to investigate the relationship between HBsAg and hepatitis B virus (HBV) DNA levels, and to determine potential applications of HBsAg level monitoring for estimating viral load. Methods 85 patients with CHB (31 pregnant women, 26 non-pregnant women, 28 men) were included in the study. HBV DNA level was measured by real-time PCR, and HBsAg level by chemiluminescent immunoassay method. Dependency between viral load and HBsAg level was determined by Spearman correlation coefficient ρ. Results The correlation between HBsAg and HBV DNA levels was significant for all patients [ρ=0.3762 (P<0.0005; n=85)]. In the group of pregnant women, a low (unmeasurable) HBV DNA level led to a decrease in the Spearman coefficient ρ. In almost all cases a low level of the HBsAg corresponded to a low HBV DNA level. Only 2 patients had a low level of HBsAg and a relatively high viral load. By contrast, a high HBsAg level was observed in patients both with high and low viral load. Conclusions Correlation between HBsAg and HBV DNA levels is significant. In most cases, a low level of HBsAg indicates a low HBV DNA level, whereas a high HBsAg level does not always correspond to a high viral load. The measurement of HBV DNA level is necessary for pregnant women with a high HBsAg level. PMID:26127004

  17. Low occurrence of HBsAg but high frequency of transient occult HBV infection in vaccinated and HBIG-administered infants born to HBsAg positive mothers.

    Science.gov (United States)

    Zhou, Shan; Li, Tingting; Allain, Jean-Pierre; Zhou, Bin; Zhang, Yuming; Zhong, Mei; Fu, Yongshui; Li, Chengyao

    2017-12-01

    The status of chronic and occult HBV infection (OBI) in neonatal hepatitis B vaccine and immunoglobulin (HBIG) vaccinated infants born to HBsAg+ mothers was investigated at a major hospital in China. Seventy-seven and 15 blood samples were collected in first or second follow-up detection from the vaccinated babies aged 3-36 months born to 43 HBsAg+ or plus 25 HBeAg+ mothers. HBV infection was analyzed between the paired baby and mother by serology and DNA analysis. Among 77 children born to 68 HBsAg+ mothers, 3.9% (3/77) were HBsAg+, and 36.4% (28/77) were HBV DNA+/HBsAg- (OBIs) by a single PCR, respectively. Thirteen of 28 HBV DNA+/HBsAg- samples were conformed by two PCRs or S sequence, which accounted for 16.9% (13/77) of children. Three HBsAg+ and six OBIs were genotyped in consistent with their mother's HBV strains. Of 77 babies' blood samples, anti-HBs reactivity varied slightly according to age groups, while passively transmitted anti-HBc reactivity declined from 100% high reactivity at age 3-5 months to mostly negative at age ≥12 months. Babies with apparent OBI had higher levels of anti-HBc and lower levels of anti-HBs than those without OBI but all eight OBI babies with second follow-up samples became HBV DNA negative beyond 1 year of age. The vaccinated infants born to HBsAg+ mothers presented the low rate of HBsAg occurrence as vaccination failure and high frequency of viral persistence in the form of transient OBIs since no evidence of active HBV infection occurred beyond 1 year of age. © 2017 Wiley Periodicals, Inc.

  18. Association of social class in HBsAg and hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Pervez, T.; Anwar, M. S.

    2001-01-01

    Objective: To find out the social class difference in relation to frequency of HBsAg and hepatocellular carcinoma in our population. Design: An analytical study. Place and Duration of Study: This study was conducted in Oncology Department, Services Hospital, Lahore from December 1997 to December 2000. Subjects and Methods: The HBsAg positive voluntary and apparently healthy blood donors were grouped into three, based on monthly income. Lower socioeconomic group and had monthly income less than 3,000 Pakistani rupees, middle socioeconomic group had monthly income between 3,000-10,000 rupees and upper socioeconomic group had income of more than 10,000 Pakistani rupees. On the same pattern patients suffering from hepatocellular carcinoma coming for treatment were also grouped. During this period, 1000 blood donors were screened for HBsAg and 95 biopsy proven liver cancer by causes were treated. Medical and demographic data of all subjects were recorded. HBsAg test was performed immuno-chromatographic technique using Daina Screen HBsAg kit manufactured by Dainabot Co. Ltd, Tokyo, Japan. Results: Patients from lower and middle social class had higher percentage (80% and 75%) of hepatocellular carcinoma as compared to higher social class (66.6%). In the healthy asymptomatic blood donors lower social class had higher (13.76%) HBsAg positively as compared to middle social class (11.25%) and higher social class (8.06%). Conclusion: Preventive measures should be taken in identifying and reducing factors predisposing high frequency of these conditions. (author)

  19. Factors Predicting HBsAg Seroclearance and Alanine Transaminase Elevation in HBeAg-Negative Hepatitis B Virus-Infected Patients with Persistently Normal Liver Function.

    Directory of Open Access Journals (Sweden)

    Tai-Long Chien

    Full Text Available A certain proportion of hepatitis B virus (HBV-infected patients with persistently normal alanine transaminase (ALT levels have significant fibrosis. Using liver stiffness measurements (Fibroscan® and laboratory data, including serum ALT, quantitative HBsAg (qHBsAg, and HBV DNA, we attempted to predict the natural histories of these patients.Non-cirrhotic HBeAg-negative chronic hepatitis B patients with persistently normal ALT were followed up prospectively with the end points of HBsAg seroclearance and ALT elevation above the upper limit of normal. The factors that were predictive of the end points were identified.A total of 235 patients with an average age of 48.1 +/- 10.7 years were followed up for 7 years. Eight patients (3.4% lost HBsAg, and 15 patients (6.4% experienced ALT elevation. The overall cumulative HBsAg seroclearances were 0.4%, 1.3% and 2.3% at years 1, 3 and 5, respectively. Regarding HBsAg seroclearance, the qHBsAg (< 30 IU/ml cutoff resulted in a hazard ratio (HR of 19.6 with a 95% confidence interval (CI of 2.2-166.7 (P = 0.008. The baseline ALT level (odd ratio (OR 1.075, 95% CI 1.020-1.132, P = 0.006 and a qHBsAg above 1000 IU/ml (3.7, 1.1-12.4, P = 0.032 were associated with ALT elevation. Limited to men, the baseline liver stiffness (1.6, 1.0-2.5, P = 0.031 and a qHBsAg above 1000 IU/ml (10.4, 2.1-52.4, P = 0.004 were factors that were independently associated with ALT elevation.A low qHBsAg level predicted HBsAg clearance. Baseline ALT and a qHBsAg above 1000 IU/ml were independent predictive factors for ALT elevation. Among the men, the independent predictive factors for ALT elevation were qHBsAg and liver stiffness.

  20. HBsAg seroprevalence in students for college entrance examination from 2006 to 2014 in Qidong of Jiangsu Province

    Directory of Open Access Journals (Sweden)

    NI Zhengping

    2015-10-01

    Full Text Available ObjectiveTo investigate the HBsAg seroprevalence in the young generation in Qidong of Jiangsu Province, China. MethodsA total of 15 534 students for college entrance examination from 2006 to 2014 were randomly selected from three secondary schools in Qidong as student group. Some of them had hepatitis B vaccination at birth. A total of 1208 adults who had their routine checkups in our hospital from 2007 to 2013 were selected as adult group. It was confirmed that all of them did not have hepatitis B vaccination at birth. Serum HBsAg levels of the two groups were measured using enzyme-linked immunosorbent assay and the seroprevalence was analyzed. Comparison of data between the two groups was made by chi-square test. Results In the 9 years from 2007 to 2013, the seroprevalence rates of HBsAg in the student group were 4.2%(75/1794, 4.3%(77/1797, 4.4%(82/1858, 4.3%(82/1903, 3.4%(56/1627, 2.6%(46/1768, 1.6%(29/1778, 1.6%(27/1642, and 1.8%(24/1367, respectively. The mean HBsAg seroprevalence of the student group was 3.2%(498/15534, significantly lower compared with 7.1% (86/1208 of the adult group (χ2= 59.986, P<0.001. In both of the student group and the adult group, the males had a significantly higher HBsAg seroprevalence than the females (χ2=10.521, P=0.001; χ2=8.452, P=0.004 and the values were 3.7%(266/7236 vs 2.8%(229/8298 and 8.8%(66/750 vs 4.4%(20/458, respectively. Among male subjects, the HBsAg seroprevalence of the adult group was 2.4 times that of the student group; among female subjects, the HBsAg seroprevalence of the adult group was 1.6 times that of the student group. ConclusionIn the recent 9 years from 2006 to 2014, the HBsAg seroprevalence in students for college entrance examination declined continuously. The goal set by the World Health Organization Western Pacific Region in 2010 had been achieved ahead of the schedule that the HBsAg seroprevalence should be controlled below 2% in children aged less than 5.

  1. Prevalence of HBsAg and anti-HBs among delivering women.

    Science.gov (United States)

    Sabău, M; Căpîlnă; Kiss, E

    1979-01-01

    A survey of 2,500 delivering women revealed a 7.6% incidence of past infection with hepatitis B virus (HBV) (HBsAg or anti-HBs). Only 5.9% of the anti-HBs-positive mothers had a possible history of parenteral exposure to hepatitis B and none of the 55 HBsAg carriers had such a history. The findings suggest that HBV is endemic and that it is probably spread in part by nonparenteral means. The high rates of HBsAg and anti-HBs point to the possible preventive value of routine screenings for this system among pregnant women.

  2. Spontaneous viral clearance, viral load, and genotype distribution of hepatitis C virus (HCV) in HIV-infected patients with anti-HCV antibodies in Europe

    DEFF Research Database (Denmark)

    Soriano, Vincent; Mocroft, Amanda; Rockstroh, Juergen

    2008-01-01

    BACKGROUND: Variables influencing serum hepatitis C virus (HCV) RNA levels and genotype distribution in individuals with human immunodeficiency virus (HIV) infection are not well known, nor are factors determining spontaneous clearance after exposure to HCV in this population. METHODS: All HCV...... for hepatitis B surface antigen (HBsAg) were more likely to have spontaneously cleared HCV than were those negative for HBsAg (43% vs. 21%; aOR, 2.91 [95% CI, 1.94-4.38]). Of patients with HCV viremia, 786 (53%) carried HCV genotype 1, and 53 (4%), 440 (29%), and 217 (15%) carried HCV genotype 2, 3, and 4...

  3. An observation on positive rate of HBsAg in the urine of patients suffering from positive serum HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Peixun, Lin; Mingzheng, Zeng; Xiaoling, Chai [Wuhan Eighth Municipal Hospital, HB (China). Dept. of Laboratory

    1989-08-01

    In 1983, the Virus Research Office of the Shanxi Research Insitute of Preventive Medicine found out the granules of hepatitis B virus from the urine of patients and proved that this kind of virus can be spread through the urine. With the help of self-developed method of radio immunoelectrophoresis, our research office has purified and concentrated the urine of the patients suffering from positive serum HBsAg (hepatitis B surface antigen). Among them 25 are male, and another 25 are female. The result shows that the positive rate of HBsAg accounts for 80%. This is of important significance to the care of urine specimens, the protection of experimentalists and the development of clinical medicine.

  4. Expression of Hepatitis B virus surface antigen (HBsAg from genotypes A, D and F and influence of amino acid variations related or not to genotypes on HBsAg detection

    Directory of Open Access Journals (Sweden)

    Natalia M. Araujo

    Full Text Available The impact of hepatitis B virus (HBV genotypes on the sensitivity of surface antigen (HBsAg detection assays has been poorly investigated. Here, plasmids carrying consensus or variant coding sequences for HBV surface proteins from genotypes A, D and F, were constructed. HBsAg levels were evaluated in medium and extracts of transfected CHO cells by a commercial polyclonal-based assay. We show that HBsAg detection values of consensus forms from genotypes D and F were, respectively, 37% and 30% lower than those obtained by genotype A. However, the presence of two single variations, T143M in genotype A, and T125M in genotype D, produced a decrease of 44% and an increase of 34%, respectively, on HBsAg mean values in comparison with their consensus forms. In conclusion, HBsAg detection levels varied among HBV genotypes. However, unique amino acid substitutions not linked to genotypes, such as T125M and T143M described here, should have more implications in HBV immunological diagnostics than the set of variations characteristic of each HBV genotype.

  5. Reactivation of hepatitis B virus infection with persistently negative HBsAg on three HBsAg assays in a lymphoma patient undergoing chemotherapy.

    Science.gov (United States)

    Cheung, Wing-I; Chan, Henry Lik-Yuen; Leung, Vincent King-Sun; Tse, Chi-Hang; Fung, Kitty; Lin, Shek-Ying; Wong, Ann; Wong, Vincent Wai-Sun; Chau, Tai-Nin

    2010-02-01

    In patients with occult hepatitis B virus (HBV) infection, acute exacerbation may occur when they become immunocompromised. Usually, these patients develop hepatitis B surface antigen (HBsAg) seroreversion during the flare. Here we report on a patient with occult HBV infection, who developed HBV exacerbation after chemotherapy for diffuse large B-cell lymphoma. The resurgence of HBV DNA preceded the elevation of liver enzymes for 20 weeks. Atypically, despite high viraemia, serological tests showed persistently negative HBsAg using three different sensitive HBsAg assays (i.e., Architect, Murex and AxSYM). On comparing the amino acid sequence of the index patient with the consensus sequence, five mutations were found at pre-S1, five at pre-S2 and twenty-three mutations at the S region. Six amino acid mutations were located in the 'a' determinant, including P120T, K122R, M133T, F134L, D144A and G145A. The mutants K122R, F134L and G145A in our patient have not been tested for their sensitivity to Architect and Murex assays by the previous investigators and might represent the escape mutants to these assays.

  6. Comparative study of methods of detection of hepatitis ′B′ surface antigen (HBsAg.

    Directory of Open Access Journals (Sweden)

    Parab V

    1989-04-01

    Full Text Available The serum samples were collected from 52 patients of acute viral hepatitis and 235 hospital staff from Kasturba Hospital for Infectious Diseases. HBsAg was detected in their sera by counter-immuno-electrophoresis (CIEP, reverse passive hemogglutination (RPHA and by micro-enzyme-linked-immunosorbent assay (ELISA technique. Among the patients, HBsAg was detected in 12 cases (23% by CIEP, in 18 cases (34% by RPHA and in 23 patients (45% by ELISA. In the hospital staff, HBsAg was detected in 4 samples (1.7% by CIEP, in 8 samples (3.5% by RPHA and in 32 samples (13.5% by ELISA. Thus ELISA was found to be the most sensitive technique in detecting HBsAg.

  7. Seroprevalence of HDV infection in HBsAg positive population in Ismailia, Egypt.

    Science.gov (United States)

    Gomaa, Nahed I M; Metwally, Lobna A; Nemr, Nader; Younis, Soha

    2013-01-01

    Hepatitis D virus (HDV) is a defective RNA virus that needs hepatitis B surface antigen (HBsAg) from HBV for transmission. HDV can lead to fulminant hepatitis and the progression of chronic liver damage in patients with chronic hepatitis B. The aim of this study was to determine the seroprevalence of HDV among HBsAg positive individuals in Ismailia, Egypt. Serum samples were collected from 170 HBsAg positive healthy individuals from Suez Canal University blood bank over a one year period. All of them were seeking blood donation and found to be HBsAg positive during viral hepatitis screening workups which is routinely done prior to donation. Serum samples were screened for IgG antibodies to hepatitis delta virus (HDV) using enzyme-linked immunosorbent assay (ELISA) method. Anti-HDV antibodies were detected in 8 (4.7%) individuals aged from 29-43 years. Liver function tests showed that serum ALT and AST levels were elevated in the HBsAglanti-HDV positive cases. It is concluded that the rate of HDV infection in Ismailia is high and further investigation is needed to validate the findings and raise awareness about the risk of dual HBV and HDV infection.

  8. Frequency of pregnant women with HBsAg in a Brazilian community Freqüência de gestantes portadoras do HBsAg em uma comunidade brasileira

    Directory of Open Access Journals (Sweden)

    Geraldo Duarte

    1997-01-01

    Full Text Available The work reported here points up the real benefits provided by neonatal immunoprophylaxis of newborns delivered by mothers who are seropositive for the hepatitis B virus surface antigen HBsAg and underscores the need to properly identify such mothers in Brazil so that immunoprophylaxis can be undertaken. To help determine levels of hepatitis B virus (HBV infection and seropositivity for various HBV markers among pregnant women in Southeast Brazil, investigators studied 7992 pregnant women delivering at the Clinical Hospital of the University of São Paulo's Ribeirão Preto School of Medicine in Ribeirão Preto, Brazil. Seroreactivity for HBsAg was determined first by serologic screening with an enzyme-linked immunosorbent assay (ELISA procedure in which the sera were incubated for 2 hours and then by confirmation with another ELISA in which the sera were incubated for 18 hours. Subsequently, tests for anti-HBsAg, HBeAg, anti-HBeAg, and anti-HBcAg markers were conducted using confirmed positive samples. Initial screening found 84 of the 7992 samples (1.05%, 95% CI: 0.84-1.30 to be positive for HBsAg; however, this HBsAg positivity was confirmed in only 76 (0.95%, 95% CI: 0.75-1.19. The positivity rate was significantly higher among subjects whose pregnancies terminated in miscarriage (1.84% than among those with live births (0.83% (chi2, Yates correction = 7.6; P = 0.005. Anamnesis was able to identify HBV risk factors in only 27.6% of the confirmed HBsAg-positive subjects or close household contacts. However, 21.3% (95% CI: 1.04-30.56 of the confirmed HBsAg-positive subjects were found positive for HBeAg, indicating a high risk of vertical transmission of the virus. These results demonstrate a need to conduct specific serologic research at term, in order to provide effective neonatal immunoprophylactic benefits.Visando aferir a tasa de reatividade sérica do HBsAg e de outros marcadores da infecção pelo VHB em parturientes, além de avaliar

  9. Natural Killer Cell Characteristics in Patients With Chronic Hepatitis B Virus (HBV) Infection Are Associated With HBV Surface Antigen Clearance After Combination Treatment With Pegylated Interferon Alfa-2a and Adefovir

    NARCIS (Netherlands)

    Stelma, Femke; de Niet, Annikki; Tempelmans Plat-Sinnige, Marjan J.; Jansen, Louis; Takkenberg, R. Bart; Reesink, Hendrik W.; Kootstra, Neeltje A.; van Leeuwen, Ester M. M.

    2015-01-01

    The role of natural killer (NK) cells in the process of hepatitis B virus (HBV) surface antigen (HBsAg) clearance and whether their phenotype is related to treatment outcome in patients with chronic hepatitis B are currently unknown. Patients with chronic hepatitis B (HBV DNA load, >17 000 IU/mL)

  10. Spontaneous HBsAg loss in Korean patients: relevance of viral genotypes, S gene mutations, and covalently closed circular DNA copy numbers

    Directory of Open Access Journals (Sweden)

    Kyun-Hwan Kim

    2014-09-01

    Full Text Available Background/AimsOccult HBV infection can persist following HBsAg loss and be transmitted, but the virological features are not well defined.MethodsHere we investigated 25 Korean patients who lost HBsAg during follow up, either spontaneously or subsequent to therapy.ResultsWhereas subtype adr (genotype C was found in 96% of HBsAg positive patients, 75 % of patients who lost HBsAg spontaneously were seemed to be infected with the ayw subtype with sequence similar to genotype D. Mutations in the major hydrophilic region (MHR of HBsAg were found in 7 patients who lost HBsAg spontaneously. The mutations include T123S, M125I/N, C139R, D144E, V177A, L192F, and W196L, some of which have not been reported before. Functional analysis via transfection experiments indicate that the C139R and D144E mutations drastically reduced HBsAg antigenicity, while the Y225del mutation found in one interferon-treated patient impaired HBsAg secretion.ConclusionsLack of detectable HBsAg in patient serum could be explained by low level of ccc DNA in liver tissue, low antigenicity of the surface protein, or its secretion defect.

  11. Viral hepatitis and rapid diagnostic test based screening for HBsAg in HIV-infected patients in rural Tanzania.

    Directory of Open Access Journals (Sweden)

    Fabian C Franzeck

    Full Text Available BACKGROUND: Co-infection with hepatitis B virus (HBV is highly prevalent in people living with HIV in Sub-Saharan Africa. Screening for HBV surface antigen (HBsAg before initiation of combination antiretroviral therapy (cART is recommended. However, it is not part of diagnostic routines in HIV programs in many resource-limited countries although patients could benefit from optimized antiretroviral therapy covering both infections. Screening could be facilitated by rapid diagnostic tests for HBsAg. Operating experience with these point of care devices in HIV-positive patients in Sub-Saharan Africa is largely lacking. We determined the prevalence of HBV and Hepatitis C virus (HCV infection as well as the diagnostic accuracy of the rapid test device Determine HBsAg in an HIV cohort in rural Tanzania. METHODS: Prospectively collected blood samples from adult, HIV-1 positive and antiretroviral treatment-naïve patients in the Kilombero and Ulanga antiretroviral cohort (KIULARCO in rural Tanzania were analyzed at the point of care with Determine HBsAg, a reference HBsAg EIA and an anti-HCV EIA. RESULTS: Samples of 272 patients were included. Median age was 38 years (interquartile range [IQR] 32-47, 169/272 (63% subjects were females and median CD4+ count was 250 cells/µL (IQR 97-439. HBsAg was detected in 25/272 (9.2%, 95% confidence interval [CI] 6.2-13.0% subjects. Of these, 7/25 (28% were positive for HBeAg. Sensitivity of Determine HBsAg was rated at 96% (95% CI 82.8-99.6% and specificity at 100% (95% CI, 98.9-100%. Antibodies to HCV (anti-HCV were found in 10/272 (3.7%, 95% CI 2.0-6.4% of patients. CONCLUSION: This study reports a high prevalence of HBV in HIV-positive patients in a rural Tanzanian setting. The rapid diagnostic test Determine HBsAg is an accurate assay for screening for HBsAg in HIV-1 infected patients at the point of care and may further help to guide cART in Sub-Saharan Africa.

  12. The impact of maternal HBsAg carrier status on pregnancy outcomes: a case-control study.

    Science.gov (United States)

    Tse, Ka Yu; Ho, Lai Fong; Lao, Terence

    2005-11-01

    To examine the impact of maternal HBsAg carrier status on pregnancy outcomes. Two hundred and fifty-three carriers of hepatitis B surface antigen (HBsAg) with singleton pregnancy, were retrospectively compared with 253 controls matched for age and parity and year of delivery. On univariable analysis, HBsAg carriers had higher incidences of threatened preterm labour at <37 weeks (11.9% vs. 6.3%, P=0.030), preterm birth at <34 weeks (4.7% vs. 1.2%, P=0.033), gestational diabetes mellitus (19.0% vs. 11.1%, P=0.012) and antepartum haemorrhage (11.5% vs. 5.5%, P=0.026). Their infants had lower Apgar scores at the 1st (8.47+/-1.67 vs. 8.87+/-1.07, P=0.001) and 5th minute (9.56+/-1.29 vs. 9.80+/-0.54, P=0.007), and increased incidence of intraventricular haemorrhage (4.7% vs. 0.8%, P=0.007). On multivariable analysis, the association between HBsAg carrier state with antepartum haemorrhage, gestational diabetes mellitus and threatened preterm labour were confirmed. HBsAg carriers have increased risk of gestational diabetes mellitus, antepartum haemorrhage, and threatened preterm labour. This may be related to the chronic inflammatory state in these subjects. The role of chronic HBV infection in pregnancy complications has to be further elucidated.

  13. Evaluation of HBsAg and anti-HBc assays in saliva and dried blood spot samples according HIV status.

    Science.gov (United States)

    Flores, Geane Lopes; Cruz, Helena Medina; Potsch, Denise Vigo; May, Silvia Beatriz; Brandão-Mello, Carlos Eduardo; Pires, Marcia Maria Amendola; Pilotto, Jose Henrique; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2017-09-01

    Influence of HIV status in HBV markers detection in saliva and dried blood spots (DBS) was not well established. This study aims to evaluate the performance of optimized commercial immunoassay for identifying HBsAg and anti-HBc in saliva and DBS according HIV status. A sum of 535 individuals grouped as HIV + , HBV + , HIV/HBV + and HIV/HBV- were recruited where 347 and 188 were included for HBsAg and anti-HBc evaluation, respectively. Serum, DBS collected in Whatman 903 paper and saliva obtained using salivette device were analyzed using EIA. Increased sample volume and ROC curve analysis for cut off determination were used for DBS and saliva testing. HBsAg detection in saliva and DBS exhibited sensitivities of 80.9% and 85.6% and specificities of 86.8% and 96.3%. Sensitivity of anti-HBc in saliva and DBS were 82.4% and 76.9% and specificities in saliva and DBS were 96.9% and 91.7%. Low sensitivities were observed for HBsAg (62%) and anti-HBc (47%) detection in saliva of HIV/HBV+ individuals. OD values were also lower for HBsAg detection in DBS and saliva of HIV/HBV+ individuals compared to their serum samples. Statistical significance was found for sensitivities in HBsAg detection between saliva and DBS demonstrating high sensitivity for DBS specimens. In conclusion, HIV status or antiretroviral treatment appears to interfere in the performance of HBsAg and anti-HBc detection in DBS and saliva samples using the adapted commercial EIA. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Quantitative HBsAg and HBeAg predict hepatitis B seroconversion after initiation of HAART in HIV-HBV coinfected individuals.

    Directory of Open Access Journals (Sweden)

    Gail V Matthews

    Full Text Available OBJECTIVE: Anti-HBe seroconversion and HBsAg loss are important therapeutic endpoints in patients with hepatitis B virus (HBV infection. Quantitative measures of hepatitis B surface antigen (qHBsAg and e antigen (qHBeAg have been identified as potentially useful indicators of therapeutic response in HBV monoinfection. The aim of this study was to examine serological change including quantitative biomarkers in HIV-HBV coinfected patients initiating HBV active antiretroviral therapy (ART. METHODS: HIV-HBV coinfected individuals from Thailand were followed for up to 168 weeks post ART. Rates and associations of qualitative serological change were determined. Longitudinal changes in qHBsAg and qHBeAg were measured and their utility as predictors of response examined. RESULTS: Forty seven patients were included of whom 27 (57% were HBeAg positive at baseline. Median CD4 count was 48 cells/mm(3. Over a median follow-up of 108 weeks 48% (13/27 lost HBeAg, 12/27 (44% achieved anti-HBe seroconversion and 13% (6/47 HBsAg loss. Anti-HBe seroconversion was associated with higher baseline ALT (p = 0.034, lower qHBsAg (p = 0.015, lower qHBeAg (p = 0.031 and greater HBV DNA decline to week 24 (p = 0.045. Sensitivity and specificity for qHBsAg and qHBeAg decline of >0.5 log at week 12 and >1.0 log at week 24 were high for both anti-HBe seroconversion and HBsAg loss. CONCLUSIONS: Rates of serological change in these HIV-HBV coinfected individuals with advanced immunodeficiency initiating HBV-active ART were high. Baseline and on treatment factors were identified that were associated with a greater likelihood of subsequent anti-HBe seroconversion, including both quantitative HBsAg and HBeAg, suggesting these biomarkers may have utility in this clinical setting.

  15. Frequency of anti-HCV, Hbsag and related risk factors in pregnant women at Nishtar Hospital, Multan

    International Nuclear Information System (INIS)

    Taseer, I.H.; Ishaq, F.; Hussain, L.; Safdar, S.; Mirbahar, A.M.; Faiz, S.A.

    2010-01-01

    Background: Viral hepatitis is a global issue. Among the hepatitis viruses hepatitis B and C are important in South Asia including Pakistan. There are various modes of transmission of these viruses. Vertical transmission is also gaining importance. Antepartum screening for HBV and HCV would help the infected women for appropriate antiviral therapy at appropriate time as well as for taking proper care of the newborns. The present study was designed to see the frequency of HBsAg and anti-HCV in pregnant women at Nishtar Hospital, Multan. Methods: This was a cross-sectional study carried out using non-probability purposive sampling technique. The period of the study was from June 2006 to August 2007. Five hundred (500) pregnant women attending outpatient department of Gynaecology and Obstetrics were included. Informed consent was taken. A specially designed proforma was filled in. Anti-HCV and HBsAg were tested by device method. Data were analyzed on SPSS-11. Results: Out of 500 pregnant women 35 (7.00%) were found to be anti-HCV positive and 23 (4.60%) were positive for HBsAg. Mean age was 26.7+-4.8 years. Majority of the patients 263 (52.60%) were in the age group 26-35 years. 138 (27.60%) women were nulliparous and 282 (56.40%) were para 1-4 and anti-HCV and HBsAg were common in this parity group. Only 80 (16.00%) women were para 5 or more. All anti-HCV and HBsAg positive women were house-wives. Most of them were belonging to rural areas having poor socio-economic status. Among 35 anti-HCV positive women, 20 (57.14%) had history of previous surgery, while 13 (37.14%) had history of multiple injections, 5 (14.28%) received blood transfusion, 4 (11.42%) had ear/nose piercing while tattooing was seen in only 2 (5.71%). Among 23 HBsAg positive women, 10 (43.47%) had history of previous surgery. History of multiple injections was present in 6 (26.08%) patients, 4 (17.39%) patients had history of blood transfusion, tattooing, ear/nose piercing, history of dental

  16. Species specificity for HBsAg binding protein endonexin II

    NARCIS (Netherlands)

    deBruin, WCC; Leenders, WPJ; Moshage, H; vanHaelst, UJGM

    Background/Aims: Hepatitis B virus displays a distinct species and tissue tropism, Previously we have demonstrated that a human liver plasma membrane protein,vith a molecular weight of approximately 34 kiloDalton specifically binds to HBsAg. This protein was identified as endonexin II, a Ca2+

  17. Clinical Characteristics and Correlation Analysis of Subjects with Chronic Hepatitis B Virus (HBV) Infection and Sustained Low Levels of Hepatitis B Surface Antigen (HBsAg)

    Science.gov (United States)

    Cheng, Jun; Dai, Yuzhu; Yan, Li; Zhou, Huajun; Xu, Xujian

    2018-01-01

    Background The aim of this study was to investigate the clinical characteristics of individuals with chronic hepatitis B virus (HBV) infection with persistent low levels of hepatitis B surface antigen (HBsAg) and to undertake a correlation analysis of the clinical characteristics. Material/Methods The study included 1,204 subjects with chronic HBV infection. Serum HBsAg, HBV envelope antigen (HBeAg), and HBV core antigen (HBcAg) levels were measured using the chemiluminescent microparticle immunoassay (CMIA) and the neutralization test. HBV DNA was measured using real-time fluorescence quantitative polymerase chain reaction (RT-FQ-PCR). Results There were 1,023 subjects in the high-level HBsAg group (HBsAg level ≥10 IU/mL) and 181 subjects in the low-level HBsAg group (HBsAg level HBV-M2), and the asymptomatic carrier (ASC) status was 98.34%. The low-level HBsAg group had a lower HBV DNA-positive rate compared with the high-level HBsAg group (40.33% vs. 75.07%), with a normal distribution across all age groups (P>0.05). The low-level HBsAg group included an older age group. A low-level of HBsAg was positively correlated with a low level of replication of HBV DNA (r=0.452). Conclusions The findings of this study showed that individuals with chronic HBV infection and sustained low-levels of HBsAg were an older population and had a lower level of replicating HBV DNA when compared with individuals with high levels of HBsAg, and the majority (93.7%) were also HBsAg and HBeAg and HBcAg-positive. PMID:29593208

  18. Value of HBsAg level in dynamic monitoring of disease progression in patients with chronic HBV infection

    Directory of Open Access Journals (Sweden)

    BAO Teng

    2017-08-01

    Full Text Available ObjectiveTo investigate the clinical value of HBsAg level in dynamic monitoring of disease progression in patients with chronic HBV infection. MethodsA retrospective analysis was performed for the clinical data of 1107 patients with different clinical stages of chronic HBV infection who had not received antiviral therapy at the time of hospitalization in The Second Affiliated Hospital of Anhui Medical University from May 2011 to December 2015, and according to the disease status, they were divided into HBeAg-positive chronic hepatitis B (CHB group, HBeAg-negative CHB group, compensated liver cirrhosis group (LC-C group, decompensated liver cirrhosis group (LC-D group, and primary liver cancer (PLC group. These groups were compared in terms of HBsAg expression and the association between HBsAg and clinical features. An analysis of variance was used for comparison of continuous data between multiple groups, and the least significant difference t-test was used for further comparison between any two groups; the t-test was used for comparison of continuous data between two groups. The chi-square test was used for comparison of categorical data between these groups. Pearson correlation analysis was also performed. ResultsThere was a significant difference in serum HBsAg level between the HBeAg-positive CHB group, HBeAg-negative CHB group, LC-C group, LC-D group, and PLC group (F=100.45, P<0.001. The HBeAg-positive CHB group had significantly higher levels of HBsAg and HBV DNA than the HBeAg-negative CHB group (t= 16.67 an 16.22, both P<0.001. There were significant differences in HBsAg and HBV DNA levels between the HBeAg-positive CHB group, LC-C group, LC-D group, and PLC group (F= 42.92 and 27.38, both P<0.001, as well as between the HBeAg-negative CHB group, LC-C group, LC-D group, and PLC group (F=6.04 and 4.10, both P<0.05. HBV DNA level was significantly different across patients with different HBsAg levels (<1000 IU/ml, 1000-20 000 IU

  19. Results of HBsAg examination with immunoelectrophoresis and radioimmunoassay in VPR, Laotian PDR and Cuban R

    Energy Technology Data Exchange (ETDEWEB)

    Michal, L; Szilagyiova, M; Zahradny, V; Holan, J; Krajnak, V [Komenskeho Univ., Martin (Czechoslovakia). Lekarska Fakulta; Padurova, J [Okresna Hygienicka Stanica, Zilina (Czechoslovakia)

    1984-06-21

    The results are compared of examining 112 Vietnamese, 30 Laotian and 50 Cuban citizens for HBsAg using IEP and RIA methods. Of the examined persons with no liver disorders HBsAg was found in 23 (31.5%) of the Vietnamese and 1 (2.5%) of the Cubans using the RIA method and only in 4 (5.5%) of the Vietnamese using the IEP method. Of the examined persons with liver disorders RIA found HBsAg in 12 (30.8%) of the Vietnamese, 5 (71.4%) of the Laotians and 2 (20.0%) of the Cubans while with IEP only in 3 (7.7%) Vietnamese 2 (28.6%) Laotians and 1 (10.0%) of the Cubans examined.

  20. Results of HBsAg examination with immunoelectrophoresis a radioimmunoassay in VPR, Laotian PDR and Cuban R

    International Nuclear Information System (INIS)

    Michal, L.; Szilagyiova, M.; Zahradny, V.; Holan, J.; Krajnak, V.

    1984-01-01

    The results are compared of examining 112 Vietnamese, 30 Laotian and 50 Cuban citizens for HBsAg using IEP and RIA methods. Of the examined persons with no liver disorders HBsAg was found in 23 (31.5%) of the Vietnamese and 1 (2.5%) of the Cubans using the RIA method and only in 4 (5.5%) of the Vietnamese using the IEP method. Of the examined persons with liver disorders RIA found HBsAg in 12 (30.8%) of the Vietnamese, 5 (71.4%) of the Laotians and 2 (20.0%) of the Cubans while with IEP only in 3 (7.7%) Vietnamese 2 (28.6%) Laotians and 1 (10.0%) of the Cubans examined. (author)

  1. [Predictive study of HBsAg in different stages of neonatal venous blood on failure of blocking HBV mother to infant transmission].

    Science.gov (United States)

    Yi, Wei; Li, Ming-Hui; Hu, Yu-Hong; Liu, Feng; Zhang, Yang-Li; Liu, Xue-Jing; Hao, Hong-Xiao; Song, Shu-Jing; Liu, Ying; Li, Xing-Hong; Sun, Ji-Yun; Liu, Min; Cheng, Jun; Xie, Yao

    2011-10-01

    In this study, we discuss the predictive value of different content of HBsAg in different stages of neotal venous blood on failure of blocking mother to infant transmission of HBV. 150 infants born of chronically HBV infected mothers who were positive of both HBsAg and HBeAg and who also had a HBV DNA virus load above 10(5) copies/ml were enrolled. These infants were given hepatitis B virus immune globin (HBIG) 200 IU immediately after birth and were given hepatitis B vaccine 10 or 20 microg at brith, 1 month and 6 months after birth. HBV serological index of these infants were test at birth, 1 month and 7 months after birth respectively. Different content of HBsAg in different stages of neonatal venus blood were analyzed to predict the failure of blocking mother to infant transmission of HBV. 11 infants failed in blocking of HBV mother to infant transmission. The positive rate of HBsAg at birth, 1 month and 7 months after birth were 41.26%, 10.49% and 7.69% respectively, and were 97.90%, 65.73% and 13.29% of HBeAg. The positive predictive value of HBsAg > or = 0.05 and HBsAg > or = 1 IU/ml at birth were 18.64% and 70% respectively, and were 73.33% and 100% one month after birth. Infants with HBsAg > or = 1 IU/ml at birth should be suspicious of failure on blocking HBV mother-to-infant transmission and it should be more credible if the infant has HBsAg > or = 1 IU/ml one month after birth. How to improve the blocking rate of neonates who were positive of HBsAg at birth and one month after birth should be the focus of our future research.

  2. Prevalence of hepatitis b virus surface antigens (HBsag) and ...

    African Journals Online (AJOL)

    The prevalences of hepatitis B virus surface antigen (HBsAg) and hepatitis C virus (HCV) antibodies were determined in 560 blood donors sera using ELISA kits (DIALAB., Austria). Forty eight (8.57%) of these were positive for hepatitis B virus infection, while 33(5.89%) were positive to hepatitis C virus antibodies. The sex ...

  3. Serologic tracers (HBsAg and HBsAc) of hepatitis B virus in expectant mothers of the Perinatal Maternal Institute; Marcadores serologicos (HBsAg y HBsAc) del virus de la hepatitis B en mujeres gestantes del Instituto Materno Perinatal

    Energy Technology Data Exchange (ETDEWEB)

    Garcia G, B M

    1997-07-01

    A study on hepatitis B tracers, (HBsAg and HBsAc), was conducted in women with different months of pregnancy at the Perinatal Maternal Institute in Lima, Peru. A total of 1010 mothers were studied during the period of January to October 1996, establishing by radioimmunoassay (RIA) whether they were positive or not. The results showed a prevalence rate of 1,6 for HBsAc and 1,3 for HBsAg for every 100,000 inhabitants. The incidence rate was 0,332 for HBsAc and 0,07 for HBsAg for every 100,000 inhabitants. This means that 21 expectant mothers are HBsAc positive and 5 are HBsAg positive. According to the investigations, there were different ways of transmission; promiscuity must be highlighted, as well as age -most of the mothers who were positive were between 20 and 25 years old- and origin. Most of them were immigrants from different places and live in shantytowns, which indicates that most of them have limited economic resources and have not received any orientation on family planning.

  4. Hepatitis B surface antigen (HBsAg) expression in plant cell culture: Kinetics of antigen accumulation in batch culture and its intracellular form.

    Science.gov (United States)

    Smith, Mark L; Mason, Hugh S; Shuler, Michael L

    2002-12-30

    The production of edible vaccines in transgenic plants and plant cell culture may be improved through a better understanding of antigen processing and assembly. The hepatitis B surface antigen (HBsAg) was chosen for study because it undergoes substantial and complex post-translational modifications, which are necessary for its immunogenicity. This antigen was expressed in soybean (Glycine max L. Merr. cv Williams 82) and tobacco NT1 (Nicotiana tabacum L.) cell suspension cultures, and HBsAg production in batch culture was characterized. The plant-derived antigen consisted predominantly of disulfide cross-linked HBsAg protein (p24(s)) dimers, which were all membrane associated. Similar to yeast, the plant-expressed HBsAg was retained intracellularly. The maximal HBsAg titers were obtained with soybean suspension cultures (20-22 mg/L) with titers in tobacco cultures being approximately 10-fold lower. For soybean cells, electron microscopy and immunolocalization demonstrated that all the HBsAg was localized to the endoplasmic reticulum (ER) and provoked dilation and proliferation of the ER network. Sucrose gradient analysis of crude extracts showed that HBsAg had a complex size distribution uncharacteristic of the antigen's normal structure of uniform 22-nm virus-like particles. The extent of authentic epitope formation was assessed by comparing total p24(s) synthesized to that reactive by polyclonal and monoclonal immunoassays. Depending on culture age, between 40% and 100% of total p24(s) was polyclonal antibody reactive whereas between 6% and 37% was recognized by a commercial monoclonal antibody assay. Possible strategies to increase HBsAg production and improve post-translational processing are discussed. Copyright 2002 Wiley Periodicals, Inc.

  5. Virus-specific immune response in HBeAg-negative chronic hepatitis B: relationship with clinical profile and HBsAg serum levels.

    Directory of Open Access Journals (Sweden)

    Elisabetta Loggi

    Full Text Available BACKGROUND AIMS: The immune impairment characterizing chronic hepatitis B (cHBV infection is thought to be the consequence of persistent exposure to viral antigens. However, the immune correlates of different clinical stages of cHBV and their relation with different levels of HBsAg have not been investigated. The aim of the present study was to evaluate the relationship between HBV-specific T cells response and the degree of in vivo HBV control and HBsAg serum levels in HBeAg-HBeAb+ cHBV. METHODS: Peripheral blood mononuclear cells from 42 patients with different clinical profiles (treatment-suppressed, inactive carriers and active hepatitis of cHBV, 6 patients with resolved HBV infection and 10 HBV-uninfected individuals were tested with overlapping peptides spanning the entire HBV proteome. The frequency and magnitude of HBV-specific T cell responses was assessed by IFNγ ELISPOT assay. Serum HBsAg was quantified with a chemiluminescent immunoassay. RESULTS: The total breadth and magnitude of HBV-specific T cell responses did not differ significantly between the four groups. However, inactive carriers targeted preferentially the core region. In untreated patients, the breadth of the anti-core specific T cell response was inversely correlated with serum HBsAg concentrations as well as HBV-DNA and ALT levels and was significantly different in patients with HBsAg levels either above or below 1000 IU/mL. The same inverse association between anti-core T cell response and HBsAg levels was found in treated patients. CONCLUSIONS: Different clinical outcomes of cHBV infection are associated with the magnitude, breadth and specificity of the HBV-specific T cell response. Especially, robust anti-core T cell responses were found in the presence of reduced HBsAg serum levels, suggesting that core-specific T cell responses can mediate a protective effect on HBV control.

  6. Detection of hepatitis B virus infection in HBsAg-negative patients by monoclonal antibodies against HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Y K

    1986-11-01

    The technique of producing antibody secreting hybridomas has made available high-affinity antibodies of predefined specificity for use as diagnostic reagents. Recently, high-affinity monoclonal antibodies to hepatitis B surface antigens (HBsAg) were produced and characterized. Immunoassay was developed using these antibodies for the detection of HBsAg-associated determinants. The present study indicated the significance of the enhanced detection by monoclonal radioimmunoassay (M-RIA) of HBsAg in sera of patients with hepatitis B virus infection. The M-RIA detected HBsAg in sera of hemodialysis patients and blood donor defined as HBsAg-negative by polyclonal RIA (2.2 %, 0.14 %, respectively). Furthermore, individuals with chronic liver diseases were reactive only in the M-RIA (chronic hepatitis 4.8 %, liver cirrhosis 10.0 %, hepatocellular carcinoma 22.2 %). It is noteworthy that some of these patients were diagnosesed as so-called non-A non-B hepatitis because of no serological markers of hepatitis B virus infection such as HBsAb and HBcAb. The enhanced performance of the monoclonal RIA compared to conventional RIA was due to the increased sensitivity of the assay (55 pg vs 230 pg/ml). In immunohistochemical study, one of the monoclonal antibody named 5C3 was applied for detection of HBsAg in the formalin-fixed paraffin-embedded liver. HBsAg was detected in 6 out of 41 HBsAg-seronegative liver specimen. Thus, the studies showed the importance of the clinical application of monoclonal antibodies such as immunoassay and immunohistochemical study in the diagnosis of hepatitis B virus infection.

  7. Detection of hepatitis B virus infection in HBsAg-negative patients by monoclonal antibodies against HBsAg

    International Nuclear Information System (INIS)

    Fujita, Y.K.

    1986-01-01

    The technique of producing antibody secreting hybridomas has made available high-affinity antibodies of predefined specificity for use as diagnostic reagents. Recently, high-affinity monoclonal antibodies to hepatitis B surface antigens (HBsAg) were produced and characterized. Immunoassay was developed using these antibodies for the detection of HBsAg-associated determinants. The present study indicated the significance of the enhanced detection by monoclonal radioimmunoassay (M-RIA) of HBsAg in sera of patients with hepatitis B virus infection. The M-RIA detected HBsAg in sera of hemodialysis patients and blood donor defined as HBsAg-negative by polyclonal RIA (2.2 %, 0.14 %, respectively). Furthermore, individuals with chronic liver diseases were reactive only in the M-RIA (chronic hepatitis 4.8 %, liver cirrhosis 10.0 %, hepatocellular carcinoma 22.2 %). It is noteworthy that some of these patients were diagnosesed as so-called non-A non-B hepatitis because of no serological markers of hepatitis B virus infection such as HBsAb and HBcAb. The enhanced performance of the monoclonal RIA compared to conventional RIA was due to the increased sensitivity of the assay (55 pg vs 230 pg/ml). In immunohistochemical study, one of the monoclonal antibody named 5C3 was applied for detection of HBsAg in the formalin-fixed paraffin-embedded liver. HBsAg was detected in 6 out of 41 HBsAg-seronegative liver specimen. Thus, the studies showed the importance of the clinical application of monoclonal antibodies such as immunoassay and immunohistochemical study in the diagnosis of hepatitis B virus infection. (author)

  8. Seropositivity of HBsAg, anti-HCV and anti-HIV in preoperative patients

    Directory of Open Access Journals (Sweden)

    Berrin Karaayak Uzun

    2014-12-01

    Full Text Available Objective: The infections caused by human immunodeficiency virus (HIV, hepatitis B (HBV and C (HCV viruses pose a serious occupational risk for the healthcare workers especially those in emergency services, laboratories and surgery wards. Vaccination and establishment of the strict biosafety procedures are the main principles to prevent blood-borne infections in healthcare workers. Additionally, serological screening of the preoperative patients could decrease the risk for exposure. In this study, we aimed to determine the seroprevalence of HBsAg, anti-HCV, anti-HIV 1/2 in preoperative patients. Methods: Hospital automation records were evaluated retrospectively for 4.367 patients who were scheduled for surgery and scanned for anti-HIV 1/2, HBsAg and anti-HCV as preoperative procedures in the preparation period of operation between January 2012 and December 2012. Results: HBsAg positivity rate was found in 7.7% (n=336, anti-HCV positivity rate was found in 2.3% (n=101. A two (0.05% of five patients were positive for anti-HIV 1/2 was found positive verification test and the other three samples were accepted as false positive test results. Conclusion: All healthcare workers must be trained about occupational diseases and vaccinated against Hepatitis B. Universal precautions must be strictly followed particularly in the operating room. In addition, all patients should be considered as potential carriers regarded as a carrier of the potential for infection. J Clin Exp Invest 2013; 4 (4: 449-452

  9. Membranous glomerulonephritis in a child asymptomatic for hepatitis B virus. Concomitant seropositivity for HBsAG and anti-HBs.

    Science.gov (United States)

    Hirsch, H Z; Ainsworth, S K; DeBeukelaer, M; Brissie, R M; Hennigar, G R

    1981-04-01

    The presence of hepatitis B surface antigen (HBsAg) in association with immunoglobulins and complement components within the glomerular basement membranes of adults having chronic active hepatitis has been well documented. In addition, investigators in Poland have demonstrated HBsAg immune complexes in glomeruli of children who did not have clinical evidence of hepatitis. More recently, a single case of childhood membranous glomerulonephritis in an asymptomatic carrier of hepatitis B virus was cited by observers in Canada. Reported here is the deposition of HBsAg immune complexes in the glomerular basement membranes of a 13-year-old black boy who had membranous glomerulopathy but not clinical evidence of hepatitis. This may be the first reported case in the United States of HbsAg-associated membranous glomerulonephritis in a child asymptomatic for hepatitis B virus, and only the second such case in North America. However, unlike previous studies of childhood glomerulopathy in association with hepatitis B virus, this patient is seropositive for both HBsAg and anti-HBs (antibody for hepatitis B surface antigen). Similar "rare" serologic findings were found for the patient's eldest male sib.

  10. Serologic tracers (HBsAg and HBsAc) of hepatitis B virus in expectant mothers of the Perinatal Maternal Institute

    International Nuclear Information System (INIS)

    Garcia G, B.M.

    1997-01-01

    A study on hepatitis B tracers, (HBsAg and HBsAc), was conducted in women with different months of pregnancy at the Perinatal Maternal Institute in Lima, Peru. A total of 1010 mothers were studied during the period of January to October 1996, establishing by radioimmunoassay (RIA) whether they were positive or not. The results showed a prevalence rate of 1,6 for HBsAc and 1,3 for HBsAg for every 100,000 inhabitants. The incidence rate was 0,332 for HBsAc and 0,07 for HBsAg for every 100,000 inhabitants. This means that 21 expectant mothers are HBsAc positive and 5 are HBsAg positive. According to the investigations, there were different ways of transmission; promiscuity must be highlighted, as well as age -most of the mothers who were positive were between 20 and 25 years old- and origin. Most of them were immigrants from different places and live in shantytowns, which indicates that most of them have limited economic resources and have not received any orientation on family planning

  11. Serological profile of incidentally detected asymptomatic HBsAg positive subjects (IDAHS)

    International Nuclear Information System (INIS)

    Khokhar, N.; Gill, M.L.

    2004-01-01

    Objective: To evaluate the serological profile of patients with incidentally detected positive hepatitis-B surface antigen (HBsAg) and to asses the risk factors. Design: An observational study. Place and Duration of Study: This study was conducted at Shifa International Hospital, Islamabad from 1999 to 2003. Patients and Methods: All patients who presented to gastroenterology clinic of Shifa Intentional Hospital, Islamabad with positive HBsAg, detected incidentally, were tested for alamine transaminase (ALT), hepatitis Beantigen (HBeAg) and in certain cases hepatitis-B virus DNA (HBV DNA) by polymerase chain reaction (PCR). Their risk factors for acquisition of infection were assessed with specific questions. Results: A total of 224 patients were examined. One hundred sixty-four (73.2%) were male and 60 (26.8%) female. Mean age of all the subjects was 32.45 plus minus 11.85 years. Out of 224 patients, 48 (21.4%) were positive for HBeAg and 176 (78.6%) were negative. Out of 48 subjects who were positive for HBeAg, 36 underwent HBV DNA determination and 32 (88.8%) were positive for HBV DNA. Out of 176 subjects who had negative HBeAg, 46 had elevated ALT and in those HBV DNA was performed and 14 had positive HBV DNA. Most common risk factors detected in these patients were intramuscular injections and surgery, however, in a large number, risk factors were unknown. Conclusion: Twenty-one percent asymptomatic subjects with positive HBsAg were found to be HBeAg positive. A large number of subjects with negative HBeAg had HBV DNA positive suggesting presence of precore mutants. Intramuscular injections and surgery were noted to be frequent risk factors in these subjects. (author)

  12. HBsAg carrier status and the association between gestational diabetes with increased serum ferritin concentration in Chinese women.

    Science.gov (United States)

    Lao, Terence T; Tse, Ka-Yu; Chan, Louis Y; Tam, Kar-Fai; Ho, Lai-Fong

    2003-11-01

    To determine whether the high prevalence of hepatitis B surface antigen (HBsAg) carriage in our population can explain the previous observation of an association between increased maternal serum ferritin concentration and gestational diabetes in Hong Kong Chinese women. A retrospective study was performed on 767 nonanemic women with singleton pregnancy who had iron status assessed at 28-30 weeks. The result of the routine antenatal HBsAg screening was retrieved from patient records. The HBsAg-positive and -negative groups were compared for maternal characteristics, prevalence of gestational diabetes in the third trimester, prevalence of high serum ferritin and iron concentrations, and transferrin saturation, which is defined as a value in the highest quartile established by the measurements obtained from the HBsAg-negative group. The incidences of oral glucose tolerance test and gestational diabetes were significantly increased in the HBsAg-positive group. The HBsAg-positive women with gestational diabetes had significantly increased prevalence of high serum ferritin compared with the HBsAg-negative women, irrespective of the latter's gestational diabetes status. Multiple logistic regression analysis confirmed the independent association between HBsAg carrier status with gestational diabetes (relative risk 3.51, 95% CI 1.83-6.73) but excluded high ferritin as an independent factor. Our results indicate that maternal HBsAg carriage could explain in part the association between increased serum ferritin concentration with gestational diabetes in Hong Kong Chinese women, and that HBsAg carrier status is an independent risk factor for gestational diabetes.

  13. Hepatitis B surface antigen concentrations in patients with HIV/HBV co-infection.

    Directory of Open Access Journals (Sweden)

    Jerzy Jaroszewicz

    Full Text Available HBsAg clearance is associated with clinical cure of chronic hepatitis B virus (HBV infection. Quantification of HBsAg may help to predict HBsAg clearance during the natural course of HBV infection and during antiviral therapy. Most studies investigating quantitative HBsAg were performed in HBV mono-infected patients. However, the immune status is considered to be important for HBsAg decline and subsequent HBsAg loss. HIV co-infection unfavorably influences the course of chronic hepatitis B. In this cross-sectional study we investigated quantitative HBsAg in 173 HBV/HIV co-infected patients from 6 centers and evaluated the importance of immunodeficiency and antiretroviral therapy. We also compared 46 untreated HIV/HBV infected patients with 46 well-matched HBV mono-infected patients. HBsAg levels correlated with CD4 T-cell count and were higher in patients with more advanced HIV CDC stage. Patients on combination antiretroviral therapy (cART including nucleos(tide analogues active against HBV demonstrated significant lower HBsAg levels compared to untreated patients. Importantly, HBsAg levels were significantly lower in patients who had a stronger increase between nadir CD4 and current CD4 T-cell count during cART. Untreated HIV/HBV patients demonstrated higher HBsAg levels than HBV mono-infected patients despite similar HBV DNA levels. In conclusion, HBsAg decline is dependent on an effective immune status. Restoration of CD4 T-cells during treatment with cART including nucleos(tide analogues seems to be important for HBsAg decrease and subsequent HBsAg loss.

  14. Purification of HBsAg produced by the human hepatoma cell line PLC/PRE/5 by affinity chromatography using monoclonal antibodies and application for ELISA diagnostic.

    Science.gov (United States)

    Merten, O W; Reiter, S; Scheirer, W; Katinger, H

    1983-01-01

    The human cell line PLC/PRF/5 (5) was used for the production of hepatitis B surface antigen subtype ad (HBsAg ad) and purified by affinity chromatography (AC) with monoclonal antibodies (mAb). mAb to HBsAg from mouse ascites have been purified by Protein A - AC prior coupling to AH-Sepharose 4B (Pharmacia). The combined procedure of ammonium-sulphate-precipitation of HBsAg from culture supernatants and immunosorbent-AC leads to approx. 700-fold purification. ELISA results using the mAb and the HBsAg for diagnostics of human serum, positive for anti-HBsAg-antibodies correlate with the RIA (AUSAB, Abbott).

  15. Detection of HBsAg and Anti HBc on donors of a blood bank by IRMA and ELISA methods

    International Nuclear Information System (INIS)

    Freire Martinez, D.Y.

    1985-10-01

    Comparative evaluation of two methods, Immunoradiometric Assay (IRMA) and Enzyme Immunoassay (ELISA), for detecting HBsAg and Anti HBc was made for determining which is the most advantageous and reliable. The study was made on 300 donors of the Hospital San Juan de Dios Blood Bank. In comparison with the reference method (IRMA), ELISA shows 91.67% of sensitivity. The Anti HBc detection by IRMA is more reliable than the HBsAg detection by IRMA and ELISA for determining the carrier state

  16. Antigens of hepatitis B virus: failure to detect HBeAg on the surfaces of HBsAg forms

    Energy Technology Data Exchange (ETDEWEB)

    Gerin, J L [Oak Ridge National Lab., Rockville, MD; Shih, J W.K.; McAuliffee, V J; Purcell, R H

    1978-01-01

    The particulate forms of HBsAg were analysed for the presence of HBeAG on their surfaces. By immunodiffusion analysis, anti-HBe did not form precipitin bands with the purified forms of HBsAg and hyperimmune guinea pig antisera to these forms did not react with HBeAg. Lines of non-identity were observed between the HBeAg determinants (e/sub 1/ and e/sub 2/) and the Dane particles and filaments isolated from an HBeAg-positive serum. Finally, anti-HBe failed to precipitate the polymerase-positive subpopulation of Dane particles, indicating that anti-HBe has no direct role in virus neutralization.

  17. A novel approach to achieving modular retrovirus clearance for a parvovirus filter.

    Science.gov (United States)

    Stuckey, Juliana; Strauss, Daniel; Venkiteshwaran, Adith; Gao, Jinxin; Luo, Wen; Quertinmont, Michelle; O'Donnell, Sean; Chen, Dayue

    2014-01-01

    Viral filtration is routinely incorporated into the downstream purification processes for the production of biologics produced in mammalian cell cultures (MCC) to remove potential viral contaminants. In recent years, the use of retentive filters designed for retaining parvovirus (~20 nm) has become an industry standard in a conscious effort to further improve product safety. Since retentive filters remove viruses primarily by the size exclusion mechanism, it is expected that filters designed for parvovirus removal can effectively clear larger viruses such as retroviruses (~100 nm). In an attempt to reduce the number of viral clearance studies, we have taken a novel approach to demonstrate the feasibility of claiming modular retrovirus clearance for Asahi Planova 20N filters. Porcine parvovirus (PPV) and xenotropic murine leukemia virus (XMuLV) were co-spiked into six different feedstreams and then subjected to laboratory scale Planova 20N filtration. Our results indicate that Planova 20N filters consistently retain retroviruses and no retrovirus has ever been detected in the filtrates even when significant PPV breakthrough is observed. Based on the data from multiple in-house viral validation studies and the results from the co-spiking experiments, we have successfully claimed a modular retrovirus clearance of greater than 6 log10 reduction factors (LRF) to support clinical trial applications in both USA and Europe. © 2013 American Institute of Chemical Engineers.

  18. A PILOT EXTERNAL QUALITY ASSURANCE STUDY OF TRANSFUSION SCREENING FOR HIV, HCV AND HBSAG IN TWELVE AFRICAN COUNTRIES

    Science.gov (United States)

    Bloch, Evan M; Shah, Avani; Kaidarova, Zhanna; Laperche, Syria; Lefrere, Jean-Jacques; van Hasselt, James; Zacharias, Peter; Murphy, Edward L

    2014-01-01

    Background and Objectives Serologic screening for the major transfusion transmissible viruses (TTV) is critical to blood safety and has been widely implemented. However, actual performance as measured by proficiency testing has not been well studied in Sub-Saharan Africa. Therefore, we conducted an external quality assessment of laboratories engaged in transfusion screening in the region. Materials and Methods Blinded test panels, each comprising 25 serum samples that were pedigreed for HIV, HBsAg, HCV and negative status, were sent to participating laboratories. The panels were tested using the laboratories’ routine donor screening methods and conditions. Sensitivity and specificity were calculated and multivariable analysis was used to compare performance against mode of testing, country and infrastructure. Results A total of 12 African countries and 44 laboratories participated in the study. The mean (range) sensitivities for HIV, HBsAg and HCV were 91.9% (14.3-100), 86.7% (42.9-100) and 90.1% (50-100), respectively. Mean specificities for HIV, HBsAg and HCV were 97.7%, 97% and 99.5% respectively. After adjusting for country and infrastructure, rapid tests had significantly lower sensitivity than enzyme immunoassays (EIA) for both HBsAg (p<0.0001) and HCV (p<0.05). Sensitivity also varied by country and selected infrastructure variables. Conclusion While specificity was high, sensitivity was more variable and deficient in a substantial number of testing laboratories. These findings underscore the importance of proficiency testing and quality control, particularly in Africa where TTV prevalence is high. PMID:25052195

  19. Adalimumab Dose Tapering in Psoriasis: Predictive Factors for Maintenance of Complete Clearance.

    Science.gov (United States)

    Hansel, Katharina; Bianchi, Leonardo; Lanza, Francesco; Bini, Vittorio; Stingeni, Luca

    2017-03-10

    Psoriasis can be managed successfully with long-term biologics. Real-life clinical practice may require dose tapering as a therapeutic option to reduce the risk of drug-exposure and to increase cost-effectiveness. The responsiveness to extended intervals between adalimumab doses and the possible predictive factors of maintenance of complete clearance were studied in a retrospective 7-year single-centre analysis. Thirty patients who achieved complete clearance with adalimumab underwent dose tapering, progressively extending between-dose intervals (to 21-28 days). Sixty percent of subjects (group A) maintained complete clearance, whereas 40.0% (group B) relapsed and were switched back to the standard dosage to re-achieve complete clearance. Body mass index (BMI) and time to achieve Psoriasis Area Severity Index (PASI-100) with adalimumab standard treatment before dose tapering were significantly lower in group A than in group B (multi-variate Cox regression: p < 0.05, Kaplan-Meier analysis: p < 0.001, respectively). This study suggests that patients with lower BMI and shorter time to achieve PASI-100 with adalimumab standard dose were significantly more likely to be candidates for dose tapering.

  20. A Clinical study of HBsAg and Anti-HBs in the serum of patients with various liver diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hak San; Kim, Jong Mann; Kim, Hwa Sook; Kim, Yul Ja; Lee, Hak Choong; Lee, Chong Suk [National Medical Center, Seoul (Korea, Republic of)

    1981-09-15

    Serum HBsAg and Anti-HBs obtained by radioimmunoassay were studied in 109 cases of various liver diseases who visited or were admitted to National Medical Center from December, 1980 to July, 1981. The results were as follows; 1) HBsAg was detected in 67.0% of total 109 cases; 71.9% of 32 cases with acute viral hepatitis, 71.4% of 14 cases with chronic hepatitis, 65.2% of 46 cases with liver cirrhosis and 58.8% of 17 cases with hepatoma. 2) Anti-HBs was detected in 32.1% of total 109 cases; 37.0% of 46 cases with liver cirrhosis, 29.4% of 17 cases with hepatoma, 28.6% of 14 cases with chronic hepatitis, 28.1% of 32 cases with acute viral hepatitis. 3) HBsAg or Anti-HBs, the markers of Hepatitis B virus was detected in 89.0% of total 109 cases; 93.6% of 32 cases with acute viral hepatitis, 89.1% of 46 cases with liver cirrhosis, 85.7% of 14 cases with chronic hepatitis and 82.4% of 17 cases with hepatoma, which strongly suggested that the various liver diseases were associated with hepatitis B virus infection.

  1. A Clinical study of HBsAg and Anti-HBs in the serum of patients with various liver diseases

    International Nuclear Information System (INIS)

    Kim, Hak San; Kim, Jong Mann; Kim, Hwa Sook; Kim, Yul Ja; Lee, Hak Choong; Lee, Chong Suk

    1981-01-01

    Serum HBsAg and Anti-HBs obtained by radioimmunoassay were studied in 109 cases of various liver diseases who visited or were admitted to National Medical Center from December, 1980 to July, 1981. The results were as follows; 1) HBsAg was detected in 67.0% of total 109 cases; 71.9% of 32 cases with acute viral hepatitis, 71.4% of 14 cases with chronic hepatitis, 65.2% of 46 cases with liver cirrhosis and 58.8% of 17 cases with hepatoma. 2) Anti-HBs was detected in 32.1% of total 109 cases; 37.0% of 46 cases with liver cirrhosis, 29.4% of 17 cases with hepatoma, 28.6% of 14 cases with chronic hepatitis, 28.1% of 32 cases with acute viral hepatitis. 3) HBsAg or Anti-HBs, the markers of Hepatitis B virus was detected in 89.0% of total 109 cases; 93.6% of 32 cases with acute viral hepatitis, 89.1% of 46 cases with liver cirrhosis, 85.7% of 14 cases with chronic hepatitis and 82.4% of 17 cases with hepatoma, which strongly suggested that the various liver diseases were associated with hepatitis B virus infection.

  2. Higher baseline viral diversity correlates with lower HBsAg decline following PEGylated interferon-alpha therapy in patients with HBeAg-positive chronic hepatitis B.

    Science.gov (United States)

    Li, Hu; Zhang, Li; Ren, Hong; Hu, Peng

    2018-01-01

    Viral diversity seems to predict treatment outcomes in certain viral infections. The aim of this study was to evaluate the association between baseline intra-patient viral diversity and hepatitis B surface antigen (HBsAg) decline following PEGylated interferon-alpha (Peg-IFN-α) therapy. Twenty-six HBeAg-positive patients who were treated with Peg-IFN-α were enrolled. Nested polymerase chain reaction (PCR), cloning, and sequencing of the hepatitis B virus S gene were performed on baseline samples, and normalized Shannon entropy (Sn) was calculated as a measure of small hepatitis B surface protein (SHBs) diversity. Multiple regression analysis was used to estimate the association between baseline Sn and HBsAg decline. Of the 26 patients enrolled in the study, 65.4% were male and 61.5% were infected with hepatitis B virus genotype B. The median HBsAg level at baseline was 4.5 log 10 IU/mL (interquartile range: 4.1-4.9) and declined to 3.0 log 10 IU/mL (interquartile range: 1.7-3.9) after 48 weeks of Peg-IFN-α treatment. In models adjusted for baseline alanine aminotransferase (ALT) and HBsAg, the adjusted coefficients (95% CI) for ΔHBsAg and relative percentage HBsAg decrease were -1.3 (-2.5, -0.2) log 10 IU/mL for higher SHBs diversity (Sn≥0.58) patients and -26.4% (-50.2%, -2.5%) for lower diversity (Sndiversity. Baseline intra-patient SHBs diversity was inverse to HBsAg decline in HBeAg-positive chronic hepatitis B (CHB) patients receiving Peg-IFN-α monotherapy. Also, more sequence variations within the "a" determinant upstream flanking region and the first loop of the "a" determinant were the main sources of the higher SHBs diversity.

  3. Genus Phyllanthus for chronic hepatitis B virus infection

    DEFF Research Database (Denmark)

    Liu, J; Lin, Haili; McIntosh, H

    2001-01-01

    To evaluate the efficacy and safety of genus Phyllanthus for chronic hepatitis B virus (HBV) infection we performed a systematic review of randomized clinical trials. Randomized trials comparing genus Phyllanthus vs. placebo, no intervention, general nonspecific treatment, other herbal medicine.......85-17.21) compared with placebo or no intervention. There was no significant difference on clearance of serum HBsAg, HBeAg and HBV DNA between Phyllanthus and IFN. Phyllanthus species were better than nonspecific treatment or other herbal medicines for the clearance of serum HBsAg, HBeAg, HBV DNA, and liver enzyme...

  4. Construction of a hepatitis B virus neutralizing chimeric monoclonal antibody recognizing escape mutants of the viral surface antigen (HBsAg).

    Science.gov (United States)

    Golsaz-Shirazi, Forough; Amiri, Mohammad Mehdi; Farid, Samira; Bahadori, Motahareh; Bohne, Felix; Altstetter, Sebastian; Wolff, Lisa; Kazemi, Tohid; Khoshnoodi, Jalal; Hojjat-Farsangi, Mohammad; Chudy, Michael; Jeddi-Tehrani, Mahmood; Protzer, Ulrike; Shokri, Fazel

    2017-08-01

    Hepatitis B virus (HBV) infection is a global burden on the health-care system and is considered as the tenth leading cause of death in the world. Over 248 million patients are currently suffering from chronic HBV infection worldwide and annual mortality rate of this infection is 686000. The "a" determinant is a hydrophilic region present in all antigenic subtypes of hepatitis B surface antigen (HBsAg), and antibodies against this region can neutralize the virus and are protective against all subtypes. We have recently generated a murine anti-HBs monoclonal antibody (4G4), which can neutralize HBV infection in HepaRG cells and recognize most of the escape mutant forms of HBsAg. Here, we describe the production and characterization of the chimeric human-murine antibody 4G4 (c-4G4). Variable region genes of heavy and light chains of the m-4G4 were cloned and fused to constant regions of human kappa and IgG1 by splice overlap extension (SOE) PCR. The chimeric antibody was expressed in Chinese Hamster Ovary (CHO)-K1 cells and purified from culture supernatant. Competition ELISA proved that both antibodies bind the same epitope within HBsAg. Antigen-binding studies using ELISA and Western blot showed that c-4G4 has retained the affinity and specificity of the parental murine antibody, and displayed a similar pattern of reactivity to 13 escape mutant forms of HBsAg. Both, the parental and c-4G4 showed a comparably high HBV neutralization capacity in cell culture even at the lowest concentration (0.6μg/ml). Due to the ability of c-4G4 to recognize most of the sub-genotypes and escape mutants of HBsAg, this antibody either alone or in combination with other anti-HBs antibodies could be considered as a potent alternative for Hepatitis B immune globulin (HBIG) as an HBV infection prophylactic or for passive immunotherapy against HBV infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Detection of S-gene 'a' determinant variants in hepatitis B patients with both positive HBsAg and HBsAb markers

    International Nuclear Information System (INIS)

    Wu Yueping; Ling Yongwu; Huang Songping; Wang Shipeng; Chen Yufeng; Mao Liping; Lu Jianrong

    2005-01-01

    Objective: To explore the S-gene 'a' determinant variants in hepatitis B patients with both positive HBsAg and HBsAb markers and the effect on the antigenicity of HBsAg. Methods: Quantitative determination of HBV - DNA with competent PCR microfluidic chit method was performed in eight sera specimens from seven hepatitis B patients with both positive HBsAg and HBsAb markers. HBV S-gene was amplified with nested PCR, the PCR product was directly examined for any sequence variant of the amino acids. HBV markers were tested with the very sensitive ELISA/MEIA method in these seven patients. The above rests were also performed in 15 children after failed immunization with hepatitis B vaccine and 9 recipients of liver transplantation for terminal hepatitis B treated with HBIG and lamivudine, serving as controls. Results: The HBsAb contents in the seven patients were all below 80 mIu/ml. Two of the patients with positive HBV-DNA showed no 'a' determinant variant. Two of the four HBV-DNA negative patients demonstrated amino-acid variants (126, 131). One patients who was originally HBV-DNA positive but later turned negative after treatment with interferon and lamivudine demonstrated variant (126). In the 9 patients after successful liver transplantation, the HBsAb contents were all about 150mIu/ml with negative HBV-DNA and no variant. In the 15 immunization failures, HBV-DNA was positive in 14 of them, with 2 cases of variant at 145, 1 case at 126 and 1 case at 134. Conclusion: In some patients with chronic B hepatitis with both positive HBsAg and HBsAb markers, as well as in some vaccine immunization failures, there were 'a' determinant variants, which might alter the antigenicity of HBsAg with escape from the neutralization of low HBsAb. The 'a' determinant variant might also affect the replication of the virus. In this study, no variant was shown in patients after successful liver transplantation. However, the number of patients was too small and the result was of no

  6. Clearance measurements on activated parts of accelerators by combined methods; Verfahrenskombinierte Freigabemessung aktivierter Beschleunigerteile

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, S.; Friedemann, S. [VKTA, Dresden (Germany); Enghardt, W. [Technische Univ. Dresden (Germany). OncoRay

    2016-07-01

    The process of clearance of radioactive materials according to paragraph 29 StrlSchV contents the comparison of activity to mass and surface of the material. To avoid a borderless assessment of activity of activation it is often necessary to use combined measurement methods: For clearance of collimators of a medical proton accelerator (energy range up to 200 MeV) it needs to know the nuclide composition. The energetical and geometrical calibration was fixed by experiments. The clearance based on measurements of activity distribution, gammaspectroscopy verification of nuclide composition and gamma-counting detectors. Parts of medical electron-accelerators achieved its clearance by combination of abovementioned methods and in-situ-gammaspectroscopy. Activated und contaminated lead stones achieved its clearance by measurements of fluence, laboratory evaluation of samples, in-situ-gammaspectroscopy and wipe tests.

  7. Historic and current hepatitis B viral DNA and quantitative HBsAg level are not associated with cirrhosis in non-Asian women with chronic hepatitis B.

    Science.gov (United States)

    Harkisoen, S; Arends, J E; van den Hoek, J A R; Whelan, J; van Erpecum, K J; Boland, G J; Hoepelman, A I M

    2014-12-01

    Some studies done in Asian patients have shown that serum levels of hepatitis B virus (HBV) DNA predict the development of cirrhosis. However, it is unclear whether this also applies for non-Asian patients. This study investigated historic and current HBV DNA and quantitative hepatitis B surface antigen (HBsAg) levels as predictors of cirrhosis in non-Asian women with chronic HBV. A retrospective cohort study of non-Asian women with chronic HBV was performed. Among other variables, HBV DNA and quantitative HBsAg levels were measured in stored historic serum samples obtained during pregnancy (period 1990-2004) and current serum samples (period 2011-2012) to determine any association with liver cirrhosis by liver stiffness measurement (LSM). One hundred and nineteen asymptomatic, treatment-naïve non-Asian women were included; the median number of years between the historic sample and the current sample was 17 (interquartile range (IQR) 13-20). The median historic log HBV DNA and quantitative log HBsAg levels were 2.5 (IQR 1.9-3.4) IU/ml and 4.2 (IQR 3.6-4.5) IU/ml, respectively. LSM diagnosed 14 patients (12%) with F3-F4 fibrosis, i.e. stiffness >8.1kPa. No association of cirrhosis was found with historic HBV DNA (relative risk (RR) 0.34, 95% confidence interval (CI) 0.05-2.44) or with the quantitative HBsAg level (HBsAg level >1000 IU/ml, RR 0.35, 95% CI 0.11-1.11). Multivariable analysis identified alcohol consumption (odds ratio (OR) 6.4, 95% CI 1.3-30.1), aspartate aminotransferase >0.5 times the upper limit of normal (OR 15.4, 95% CI 1.9-122.6), and prothrombin time (OR 12.0, 95% CI 1.2-120.4), but not HBV DNA or quantitative HBsAg level, to be independent predictors of the presence of cirrhosis. Neither historic nor current HBV DNA or the quantitative HBsAg level is associated with the development of HBV-related cirrhosis in non-Asian women. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Posintro™-HBsAg, a modified ISCOM including HBsAg, induces strong cellular and humoral responses

    DEFF Research Database (Denmark)

    Schiött, Asa; Larsson, Kristina; Manniche, Søren

    2011-01-01

    HBsAg vaccine formulation, Posintro™-HBsAg, was compared to two commercial hepatitis B vaccines including aluminium or monophosphoryl lipid A (MPL) and the two adjuvant systems MF59 and QS21 in their efficiency to prime both cellular and humoral immune responses. The Posintro™-HBsAg induced...

  9. Immune-escape mutations and stop-codons in HBsAg develop in a large proportion of patients with chronic HBV infection exposed to anti-HBV drugs in Europe

    DEFF Research Database (Denmark)

    Colagrossi, Luna; Hermans, Lucas E; Salpini, Romina

    2018-01-01

    structure of HBV genome, some immune-escape mutations or stop-codons in HBsAg can derive from drug-resistance mutations in RT. This study is aimed at gaining insight in prevalence and characteristics of immune-associated escape mutations, and stop-codons in HBsAg in chronically HBV-infected patients...

  10. Lung mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, J.; Lange, P.; Nyboe, J.; Groth, S.

    1994-01-01

    The aim of this study was to establish reference values for mucociliary clearance and mucociliary clearance reserve capacity as determined by β 2 -adrenergic agonist-induced increase in mucociliary clearance. We studied 62 healthy females (n=33) and males (n=29). Their ages ranged evenly between 18 and 84 years. Fifty-three of the subjects were life-long non-smokers, while nine were ex-smokers. Multiple linear regression analyses showed that mucociliary clearance was significantly faster when the radioaerosol was deposited in the central airways than when it was deposited in the peripheral airways, and faster in life-long non-smokers than in ex-smokers. There was no influence of age, and no convincing association with sex. The variation was less within than between subjects. Mean mucociliary clearance reserve capacity was 21.3% (SD: 10.0%, P 2 agonist-induced increase in lung mucociliary clearance was significantly larger (P<0.05) than the stimulation which has previously been reported in patients with asthma, bronchiectasis or cystic fibrosis. The signal-to-noise ratio of the mucociliary clearance reserve capacity in relation to measurement of baseline mucociliary clearance indicates that measurement of mucociliary clearance reserve capacity may be a more efficient means of distinguishing between ''normal'' and ''abnormal'' mucociliary clearance than single measurement of baseline mucociliary clearance. (orig.)

  11. Isolated HBsAg positivity in a Mexican patient with newly diagnosed lupus nephritis

    Directory of Open Access Journals (Sweden)

    Guillermo Delgado-García

    2017-01-01

    Conclusions: Isolated HBsAg positivity may result from multiple causes, one of which is cross-reactivity. To the best of our knowledge, this is the first report of a false-positive reading using CMIA technique in an active lupus patient. It is reasonable to stress that lupus patients with a positive screening for HBV should undergo a confirmatory assay (such as genomic detection, since this diagnosis may have important therapeutic implications.

  12. Isotope determinations of renal clearance equivalent with physiological clearance measurements

    International Nuclear Information System (INIS)

    Junges, R.

    1983-01-01

    The concept of renal clearance in nuclear medicine describes the tubular secretion and glomerular filtration of a substance being removed from the blood plasma. The concept of clearance as used physiologically is rather wider and includes consideration of the outflow of the substances remained back in the kidneys. The present paper discusses clearance measurements as seen from a thermodynamic point of view, in which isotope clearances become equivalent with the physiological concept of clearance. In addition, it is possible to quantify each single step of the excretory function of each kidney separately. (orig.) [de

  13. Comparison of the endogenous creatinine clearance, the creatinin clearance calculated without urine collection and the isotope clearance

    International Nuclear Information System (INIS)

    Mohacsi, Gabor; Lang, Jenoe; Csernay, Laszlo; Sonkodi, Sandor; Orvostudomanyi Egyetem, Szeged

    1987-01-01

    Observations are reported relating to the endogenous creatinine clearance, the Tc-99m-EDTA-complex clearance and the creatinine clearance estimated via a selected mathematical formula, with special regard to the problems of renal insufficiency and the nephrotic syndrome. The activity applied was in the range of 3.7-7.4 MBq. It was observed that measurement of the isotope clearance can also be applied to determine the endogeneous creatinine clearance in otherwise less suitable patients. A reliable result is obtained even if the renal function is restricted, but the accuracy of the method may be reduced in nephrotic syndrome cases. (author) 24 refs

  14. Creatinine clearance test

    Science.gov (United States)

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ...

  15. HBsAg d and y subtypes determined by inhibition radio-immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, R [Border Blood Transfusion Service, East London (South Africa)

    1981-12-01

    An inhibition radioimmunoassay for the detection of HBsAg/d and HBsAg/y antigens is described. A survey of 211 asymptomatic HBsAg positive blood donors showed 190 to be of type HBsAg/d and 3 to be of type HBsAg/y, while the remaining 18 could not be typed. Of 43 patients with acute hepatitis 39 were type HBsAg/d and 4 were type HBsAg/y. The statistically significant (p smaller than 0,01) increase in type HBsAg/y may reflect a changing pattern in offending viral strain with the passage of time.

  16. Lactate clearance cut off for early mortality prediction in adult sepsis and septic shock patients

    Science.gov (United States)

    Sinto, R.; Widodo, D.; Pohan, H. T.

    2018-03-01

    Previous lactate clearance cut off for early mortality prediction in sepsis and septic shock patient was determined by consensus from small sample size-study. We investigated the best lactate clearance cut off and its ability to predict early mortality in sepsis and septic shock patients. This cohort study was conducted in Intensive Care Unit of CiptoMangunkusumo Hospital in 2013. Patients’ lactate clearance and eight other resuscitationendpoints were recorded, and theoutcome was observed during the first 120 hours. The clearance cut off was determined using receiver operating characteristic (ROC) analysis, and its ability was investigated with Cox’s proportional hazard regression analysis using other resuscitation endpoints as confounders. Total of 268 subjects was included, of whom 70 (26.11%) subjects died within the first 120 hours. The area under ROC of lactate clearance to predict early mortality was 0.78 (95% % confidence interval [CI] 0.71-0.84) with best cut off was <7.5% (sensitivity and specificity 88.99% and 81.4% respectively). Compared with group achieving lactate clearance target, group not achieving lactate clearance target had to increase early mortality risk (adjusted hazard ratio 13.42; 95%CI 7.19-25.07). In conclusion, the best lactate clearance cut off as anearly mortality predictor in sepsis and septic shock patients is 7.5%.

  17. Screening of HBsAg and anti HCV from tertiary care, private and public sector hospitals

    International Nuclear Information System (INIS)

    Khan, R.A.W.; Ahmed, W.; Alam, S.E.; Arif, A

    2011-01-01

    Objectives: To find out the frequency of hepatitis B surface antigen and hepatitis C antibodies in patients referred from a tertiary care public sector hospital, other public sector and private hospitals of Karachi. Settings and duration: Pakistan Medical Research Council's Specialized Research Centre for Gastroenterology and Hepatology, at Jinnah Postgraduate Medical Centre Karachi from January to December 2009. Patients and Methods: A cross sectional study was conducted where patients were referred from different departments of Jinnah Postgraduate Medical Centre (tertiary care public sector hospital), other public sector hospitals, private hospitals and clinics for the screening of hepatitis B and C virus infection. Three ml blood was collected from each patient, serum separated and tested for HBsAg and Anti HCV using Abbott Murex fourth Generation ELISA kits. Results: A total of 2965 cases were referred in a year. Overall sero prevalence of HBsAg and Anti-HCV was 5.9% and 12.8% respectively. HBsAg positivity in patient referred from public sector hospitals was 5.8%, those from private hospitals/clinics were 7.2%, and self-referred patients was 5.6%. Anti HCV positivity rates amongst these cases were 12.5%, 16.7% and 8.5% respectively. Co-infection of hepatitis B virus and hepatitis C virus was seen in 0.9, 2.5 and 1.4% cases respectively. Breakdown of viral positivity within different departments of Jinnah Postgraduate Medical Centre Karachi showed HBsAg positivity of 7.1% in Medical department, 5.2% in Surgical department, 5.0% in Gynaecology department, 6.6% in other departments of Jinnah Postgraduate Medical Centre while, only 1.7% were positive from Pakistan Railway, hospital Anti HCV positivity was maximally (20.3%) seen in medical department followed by 14% in other departments, 10.9% in surgical department, 7.9% in gynaecology and 5.1% in railway hospital. Co-infection of HBV and HCV was seen in 2% cases referred from medical department, while rest of the

  18. A meta-analysis of the antiviral activity of the HBV-specific immunotherapeutic TG1050 confirms its value over a wide range of HBsAg levels in a persistent HBV pre-clinical model.

    Science.gov (United States)

    Kratzer, Roland; Sansas, Benoît; Lélu, Karine; Evlachev, Alexei; Schmitt, Doris; Silvestre, Nathalie; Inchauspé, Geneviève; Martin, Perrine

    2018-02-01

    Pre-clinical models mimicking persistent hepatitis B virus (HBV) expression are seldom, do not capture all features of a human chronic infection and due to their complexity, are subject to variability. We report a meta-analysis of seven experiments performed with TG1050, an HBV-targeted immunotherapeutic, 1 in an HBV-persistent mouse model based on the transduction of mice by an adeno-associated virus coding for an infectious HBV genome (AAV-HBV). To mimic the clinical diversity seen in HBV chronically infected patients, AAV-HBV transduced mice displaying variable HBsAg levels were treated with TG1050. Overall mean percentages of responder mice, displaying decrease in important clinical parameters i.e. HBV-DNA (viremia) and HBsAg levels, were 52% and 51% in TG1050 treated mice, compared with 8% and 22%, respectively, in untreated mice. No significant impact of HBsAg level at baseline on response to TG1050 treatment was found. TG1050-treated mice displayed a significant shorter Time to Response (decline in viral parameters) with an Hazard Ratio (HR) of 8.3 for viremia and 2.6 for serum HBsAg. The mean predicted decrease for TG1050-treated mice was 0.5 log for viremia and 0.8 log for HBsAg, at the end of mice follow-up, compared to no decrease for viremia and 0.3 log HBsAg decrease for untreated mice. For mice receiving TG1050, a higher decline of circulating viremia and serum HBsAg level over time was detected by interaction term meta-analysis with a significant treatment effect (p = 0.002 and pHBV-persistent model mimicking clinical situations.

  19. Reactivation of viral replication in anti-HBe positive chronic HBsAg carriers

    DEFF Research Database (Denmark)

    Krogsgaard, K; Aldershvile, J; Kryger, Peter

    1990-01-01

    Reactivation of hepatitis B virus replication was investigated in an unselected group of 44 HBV DNA negative, anti-HBe positive chronic HBsAg carriers. Twenty-five patients (54%) were intravenous drug addicts and 7 (16%) were male homosexuals. Sixteen patients had evidence of delta infection...... to an annual reactivation rate of 5%. Reactivation in four patients was detected by reversion to HBV DNA positivity only, whereas HBeAg/anti-HBe status remained unchanged. Two patients became both HBV DNA and HBeAg positive. None of the patients developed hepatitis-like symptoms and transaminase elevation...

  20. [51Cr]EDTA plasma clearance and endogenous creatinine clearance in advanced renal insufficiency

    International Nuclear Information System (INIS)

    Svendsen, U.G.; Munck, O.; Czartoryski, A.; Stafanger, G.

    1978-01-01

    Comparison of [ 51 Cr]EDTA plasma clearance corrected for extrarenal elimination with 24 h endogenous creatinine clearance in patients with advanced renal failure showed that the corrected [ 51 Cr]EDTA clearance was lower than creatinine clearance, and thus might be a better approximation to the glomerular filtration rate in uraemic patients. The corrections cannot be used on [ 51 Cr]EDTA clearance values below the mean extrarenal clearance, averaging 3.7 ml/min. (Auth.)

  1. Rational design and evaluation of HBsAg polymeric nanoparticles as antigen delivery carriers.

    Science.gov (United States)

    Dewangan, Hitesh Kumar; Pandey, Tarun; Maurya, Lakshmi; Singh, Sanjay

    2018-05-01

    The present work is focused on the development and evaluation of single dose sustained-release Hepatitis B surface antigen (HBsAg) loaded nanovaccine for Hepatitis B. The conventional treatment suffers from repeated administration and hence requires a booster dose. Therefore, polymeric nanovaccine of HBsAg was developed by double emulsion solvent evaporation technique, utilizing central composite design for formulation optimization. The effects of independent variables (like polymer amount, stabilizer concentration, aqueous/organic phase ratio and homogenizer speed) were also studied on critical quality attributes like particle size and entrapment efficiency. Nanovaccine was characterized in terms of physicochemical parameters, release, internalization and in vivo immunological evaluation in BALB/c mice after administration by different routes such as oral, sub-cutaneous, nasal and intramuscular. The designed nanovaccine demonstrated nanometric size with smooth surface, negative zeta potential, maximum entrapment, sustained release and better internalization in macrophage and MRC-5 cell line. The immune-stimulating activity of nanovaccine administered by different routes was evaluated by measuring anti-HBsAg titre like specific immunoglobulin IgG and IgA response and cytokine level (interleukin-2, interferon-Y) measurement. The results indicated that the nanovaccine administered by intramuscular route produced better humoral as well as cellular responses and potential carriers for antigen delivery at single dose administration via intramuscular route. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  3. Antibody-mediated immunotherapy against chronic hepatitis B virus infection.

    Science.gov (United States)

    Gao, Ying; Zhang, Tian-Ying; Yuan, Quan; Xia, Ning-Shao

    2017-08-03

    The currently available drugs to treat hepatitis B virus (HBV) infection include interferons and nucleos(t)ide analogs, which can only induce disease remission and are inefficient for the functional cure of patients with chronic HBV infection (CHB). Since high titers of circulating hepatitis B surface antigen (HBsAg) may be essential to exhaust the host anti-HBV immune response and they cannot be significantly reduced by current drugs, new antiviral strategies aiming to suppress serum hepatitis B surface antigen (HBsAg) could help restore virus-specific immune responses and promote the eradication of the virus. As an alternative strategy, immunotherapy with HBsAg-specific antibodies has shown some direct HBsAg suppression effects in several preclinical and clinical trial studies. However, most described previously HBsAg-specific antibodies only had very short-term HBsAg suppression effects in CHB patients and animal models mimicking persistent HBV infection. More-potent antibodies with long-lasting HBsAg clearance effects are required for the development of the clinical application of antibody-mediated immunotherapy for CHB treatment. Our recent study described a novel mAb E6F6 that targets a unique epitope on HBsAg. It could durably suppress the levels of HBsAg and HBV DNA via Fcγ receptor-dependent phagocytosis in vivo. In this commentary, we summarize the current research progress, including the therapeutic roles and mechanisms of antibody-mediated HBV clearance as well as the epitope-determined therapeutic potency of the antibody. These insights may provide some clues and guidance to facilitate the development of therapeutic antibodies against persistent viral infection.

  4. Micropropagation of transgenic lettuce containing HBsAg as a method of mass-scale production of standardised plant material for biofarming purposes.

    Science.gov (United States)

    Pniewski, Tomasz; Czyż, Marcin; Wyrwa, Katarzyna; Bociąg, Piotr; Krajewski, Paweł; Kapusta, Józef

    2017-01-01

    Micropropagation protocol of transgenic lettuce bearing S-, M- and L-HBsAg was developed for increased production of uniformised material for oral vaccine preparation. Effective manufacturing of plant-based biopharmaceuticals, including oral vaccines, depends on sufficient content of a protein of interest in the initial material and its efficient conversion into an administrable formulation. However, stable production of plants with a uniformised antigen content is equally important for reproducible processing. This can be provided by micropropagation techniques. Here, we present a protocol for micropropagation of transgenic lettuce lines bearing HBV surface antigens: S-, M- and L-HBsAg. These were multiplied through axillary buds to avoid the risk of somaclonal variation. Micropropagation effectiveness reached 3.5-5.7 per passage, which implies potential production of up to 6600 plant clones within a maximum 5 months. Multiplication and rooting rates were statistically homogenous for most transgenic and control plants. For most lines, more than 90 % of clones obtained via in vitro micropropagation had HBsAg content as high as reference plants directly developed from seeds. Clones were also several times more uniform in HBsAg expression. Variation coefficients of HBsAg content did not exceed 10 % for approximately 40-85 % of clones, or reached a maximum 20 % for 90 % of all clones. Tissue culture did not affect total and leaf biomass yields. Seed production for clones was decreased insignificantly and did not impact progeny condition. Micropropagation facilitates a substantial increase in the production of lettuce plants with high and considerably equalised HBsAg contents. This, together with the previously reported optimisation of plant tissue processing and its long-term stability, constitutes a successive step in manufacturing of a standardised anti-HBV oral vaccine of reliable efficacy.

  5. Optimization Based Clearance of Flight Control Laws A Civil Aircraft Application

    CERN Document Server

    Hansson, Anders; Puyou, Guilhem

    2012-01-01

    This book summarizes the main achievements of the EC funded 6th Framework Program project COFCLUO – Clearance of Flight Control Laws Using Optimization. This project successfully contributed to the achievement of a top-level objective to meet society’s needs for a more efficient, safer and environmentally friendly air transport by providing new techniques and tools for the clearance of flight control laws. This is an important part of the certification and qualification process of an aircraft – a costly and time-consuming process for the aeronautical industry.   The overall objective of the COFCLUO project was to develop and apply optimization techniques to the clearance of flight control laws in order to improve efficiency and reliability. In the book, the new techniques are explained and benchmarked against traditional techniques currently used by the industry. The new techniques build on mathematical criteria derived from the certification and qualification requirements together with suitable models...

  6. Mucociliary clearance

    DEFF Research Database (Denmark)

    Munkholm, Mathias; Mortensen, Jann

    2014-01-01

    Mucociliary clearance has long been known to be a significant innate defence mechanism against inhaled microbes and irritants. Important knowledge has been gathered regarding the anatomy and physiology of this system, and in recent years, extensive studies of the pathophysiology related to lung...... pharmacological interventions on clearance rate, to study the importance of defective mucus clearance in different lung diseases or as a diagnostic tool in the work-up of patients with recurrent airway diseases. The aim of this review is to provide an overview of the anatomy, physiology, pathophysiology...

  7. Infección oculta por el virus de la hepatitis B en hijos de madres positivas al HBsAg

    Directory of Open Access Journals (Sweden)

    Marité Bello-Corredor

    2016-04-01

    Full Text Available La infección oculta por el virus de la hepatitis B (IOB, se caracteriza por la presencia en suero o plasma del genoma viral (ADN-VHB y anticuerpos contra la proteína de la cápside (anti-HBc en ausencia del antígeno de superficie (HBsAg, marcador que tradicionalmente se emplea para identificar la presencia del virus. Con el objetivo de caracterizar la presencia de IOB en hijos de madres positivas al HBsAg, se estudiaron 291 muestras séricas de niños con la condición de ser HBsAg (- y anticuerpos anti-HBsAg (anti-HBs menores de 50 UI/L, conservadas en la seroteca del Laboratorio de Referencia Nacional de Hepatitis Virales. Se realizaron ensayos para determinar la exposición al virus (anti-HBc, a los sueros anti-HBc (+ se les realizó Reacción en Cadena de la Polimerasa en Tiempo Real (RCP-TR para determinar y cuantificar el ADN-VHB. La prevalencia de exposición al VHB (anti-HBc fue 16,8% (49/291. El ADN viral se cuantificó en el 14% (6/43 de los casos anti-HBc (+, observándose cargas virales que oscilaban entre 2,15 x 101 hasta 3,42 x 101 UI/mL. La prevalencia de la IOB para el total de los pacientes analizados fue 2,1% (6/291, considerada relativamente baja. No se encontró asociación significativa entre las variables sociodemográficas analizadas tales como: edad, sexo y provincia de procedencia. La IOB está presente en hijos de madres positivas al HBsAg, a pesar de la profilaxis contra la hepatitis B. Por lo tanto, se requiere de pesquisajes adecuados para detectar dicha entidad. Las implicaciones clínicas y epidemiológicas de la misma, requieren de un estrecho monitoreo y atención de estos pacientes. Este estudio se realiza por primera vez en Cuba y aporta conocimientos útiles para el diagnóstico, prevención y control de esta enfermedad en niños.

  8. Correlation between HBsAg, prothrombin time activity, and indocyanine green retention rate at 15 minutes in patients with HBeAg-positive chronic HBV infection

    Directory of Open Access Journals (Sweden)

    FAN Wenhai

    2016-11-01

    Full Text Available ObjectiveTo investigate the correlation between HBsAg, prothrombin time activity (PTA, and indocyanine green retention rate at 15 minutes (ICG R15 in patients with HBeAg-positive chronic HBV infection. MethodsA total of 92 patients with HBeAg-positive chronic HBV infection who were admitted to The First Hospital of Lanzhou University from December 2015 to April 2016 were enrolled and divided into chronic hepatitis B (CHB group (24 patients, compensated liver cirrhosis group (38 patients, and decompensated liver cirrhosis group (30 patients. Serum HBsAg quantitation, PTA test, and liver reserve function test (ICG R15 were performed for all patients. The chi-square test was used for comparison of categorical data between groups, an analysis of variance was used for comparison of continuous data between multiple groups, and a Pearson correlation analysis was also performed. ResultsThere were significant differences between the three groups in serum HBsAg quantitation (3.82±0.43 log10IU/ml vs 2.88±0.36 log10IU/ml vs 2.60±0.27 log10IU/ml, F=25.19, P<0.001, ICG R15 (7.51%±3.10% vs 9.57%±8.18% vs 24.13%±14.28%, F=24.00, P=0.001, and PTA (8100%±1762% vs 83.08%±9.64% vs 62.32%±16.90%, F=13.42, P=0.009. The correlation analysis showed that PTA was negatively correlated with ICG R15 in all three groups (r=-0.948, -0.602, and -0.735, all P<0.01. In the compensated liver cirrhosis group and decompensated liver cirrhosis group, HBsAg was positively correlated with PTA (r=0.410 and 0.473, both P<0.05 and negatively correlated with ICG R15 (r=-0.427 and -0.768, P<0.01. ConclusionIn HBeAg positive patients, there are certain correlations between HBsAg, PTA, and ICG R15, which, to a certain degree, reflects the liver reserve function in patients with chronic HBV infection.

  9. DNA immunization with fusion of CTLA-4 to hepatitis B virus (HBV core protein enhanced Th2 type responses and cleared HBV with an accelerated kinetic.

    Directory of Open Access Journals (Sweden)

    Ying Yin

    Full Text Available BACKGROUND: Typically, DNA immunization via the intramuscular route induces specific, Th1-dominant immune responses. However, plasmids expressing viral proteins fused to cytotoxic T lymphocyte antigen 4 (CTLA-4 primed Th2-biased responses and were able to induced effective protection against viral challenge in the woodchuck model. Thus, we addressed the question in the mouse model how the Th1/Th2 bias of primed immune responses by a DNA vaccine influences hepatitis B virus (HBV clearance. PRINCIPAL FINDINGS: Plasmids expressing HBV core protein (HBcAg or HBV e antigen and HBcAg fused to the extracellular domain of CTLA-4 (pCTLA-4-HBc, CD27, and full length CD40L were constructed. Immunizations of these DNA plasmids induced HBcAg-specific antibody and cytotoxic T-cell responses in mice, but with different characteristics regarding the titers and subtypes of specific antibodies and intensity of T-cell responses. The plasmid pHBc expressing HBcAg induced an IgG2a-dominant response while immunizations of pCTLA-4-HBc induced a balanced IgG1/IgG2a response. To assess the protective values of the immune responses of different characteristics, mice were pre-immunized with pCTLA-4-HBc and pHBc, and challenged by hydrodynamic injection (HI of pAAV/HBV1.2. HBV surface antigen (HBsAg and DNA in peripheral blood and HBcAg in liver tissue were cleared with significantly accelerated kinetics in both groups. The clearance of HBsAg was completed within 16 days in immunized mice while more than 50% of the control mice are still positive for HBsAg on day 22. Stronger HBcAg-specific T-cell responses were primed by pHBc correlating with a more rapid decline of HBcAg expression in liver tissue, while anti-HBs antibody response developed rapidly in the mice immunized with pCTLA-4-HBc, indicating that the Th1/Th2 bias of vaccine-primed immune responses influences the mode of viral clearance. CONCLUSION: Viral clearance could be efficiently achieved by Th1/Th2-balanced

  10. Development of the clearance level verification evaluation system. 2. Construction of the clearance data management system

    International Nuclear Information System (INIS)

    Kubota, Shintaro; Usui, Hideo; Kawagoshi, Hiroshi

    2014-06-01

    Clearance is defined as the removal of radioactive materials or radioactive objects within authorized practices from any further regulatory control by the regulatory body. In Japan, clearance level and a procedure for its verification has been introduced under the Laws and Regulations, and solid clearance wastes inspected by the national authority can be handled and recycled as normal wastes. The most prevalent type of wastes have generated from the dismantling of nuclear facilities, so the Japan Atomic Energy Agency (JAEA) has been developing the Clearance Level Verification Evaluation System (CLEVES) as a convenient tool. The Clearance Data Management System (CDMS), which is a part of CLEVES, has been developed to support measurement, evaluation, making and recording documents with clearance level verification. In addition, validation of the evaluation result of the CDMS was carried out by inputting the data of actual clearance activities in the JAEA. Clearance level verification is easily applied by using the CDMS for the clearance activities. (author)

  11. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  12. The HBsAg Prevalence Among Blood Donors From Eastern Mediterranean and Middle Eastern Countries: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Babanejad, Mehran; Izadi, Neda; Najafi, Farid; Alavian, Seyed Moayed

    2016-03-01

    The world health organization (WHO) recommends that all blood donations should be screened for evidence of infections, such as hepatitis B. The present study aimed to determine the prevalence of hepatitis B surface antigen (HBsAg) in blood donors at the eastern Mediterranean region office (EMRO) of the WHO and middle eastern countries. A meta-analysis was carried out based on the results of an electronic literature search of PubMed, Ovid, Scopus, and Google Scholar for articles published from January 1, 2000, to August 31, 2015. In accordance with a significant homogeneity test and a large value of I2, the random effects model was used to aggregate data from the studies and produce the pooled estimates using the "Metan" command. We included 66 eligible studies. The pooled prevalence of HBsAg in blood donors of both EMRO and middle eastern (E and M) countries was 2.03% (95% confidence interval [CI]: 1.79 - 2.26). In addition, the prevalence rates in the EMRO countries was 1.99% (95% CI: 1.84 - 2.14) and 1.62% in the Middle Eastern countries (95% CI: 1.36 - 1.88). The prevalence among blood donors with more than one study was 1.58% in Egypt, 0.58% in Iran, 0.67% in Iraq, 2.84% in Pakistan, 3.02% in Saudi Arabia, 1.68% in Turkey, and 5.05% in Yemen. Based on the WHO classification of hepatitis B virus (HBV) prevalence, the prevalence of HBsAg in blood donors from E and M countries reached an intermediate level. However, there were low prevalence levels in some E and M countries.

  13. Optimisation of secretion of recombinant HBsAg virus-like particles: Impact on the development of HIV-1/HBV bivalent vaccines

    NARCIS (Netherlands)

    Michel, Marie; Lone, Yu-Chun; Centlivre, Mireille; Roux, Pascal; Wain-Hobson, Simon; Sala, Monica

    2007-01-01

    The hepatitis B surface antigen (HBsAg) assembles into virus-like particles (VLPs) that can be used as carrier of immunogenic peptides for the development of bivalent vaccine candidates. It is shown here that by respecting certain qualitative features of mammalian preS1 and preS2 protein domains

  14. Differing results of direct and indirect solid phase radioimmunoassay for HBsAg in acute hepatitis

    International Nuclear Information System (INIS)

    Strohm, W.D.; Legler, K.; Gerlich, W.; Stamm, B.; Zimmer, S.; Biotest-Serum-Institut G.m.b.H., Frankfurt am Main; Goettingen Univ.

    1978-01-01

    In 54 patients suffering from active viral hepatitis the indirect solid phase radioimmunoassay (ind-SPRIA) for HBsAg was positive in 9 cases the direct solid phase radioimmunoassay (d-SPRIA) being negative. In 2 further cases ind-SPRIA was positive during several weeks but d-SPRIA only once. AntiHBc could be detected in 9 of these patients. In 7 patients the usual decrease of the transaminase activity was followed by a second elavation with prolongation of the disease. The unknown factor detected by ind-SPRIA suggests a special of acute hepatitis. (orig.) [de

  15. Differing results of direct and indirect solid phase radioimmunoassay for HBsAg in acute hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Strohm, W D; Legler, K; Gerlich, W; Stamm, B; Zimmer, S [Frankfurt Univ. (Germany, F.R.). Abt. fuer Gastroenterologie; Biotest-Serum-Institut G.m.b.H., Frankfurt am Main (Germany, F.R.); Goettingen Univ. (Germany, F.R.). Hygiene-Institut)

    1978-09-01

    In 54 patients suffering from active viral hepatitis the indirect solid phase radioimmunoassay (ind-SPRIA) for HBsAg was positive in 9 cases the direct solid phase radioimmunoassay (d-SPRIA) being negative. In 2 further cases ind-SPRIA was positive during several weeks but d-SPRIA only once. AntiHBc could be detected in 9 of these patients. In 7 patients the usual decrease of the transaminase activity was followed by a second elavation with prolongation of the disease. The unknown factor detected by ind-SPRIA suggests a special of acute hepatitis.

  16. Activation and clearance of vanadium alloys and beryllium multipliers in fusion reactors

    International Nuclear Information System (INIS)

    Bartenev, S.; Romanovskij, V.; Ciampichetti, A.; Zucchetti, M.; Forrest, R.; Kolbasov, B.; Romanov, P.

    2006-01-01

    Design of fusion reactors includes the development of low-activation materials. V-Cr-Ti alloys are among the candidate structural materials for the first wall and blanket, with the scarce and costly V as the main component. It is worth considering its regeneration and refabrication as well as to avoid its disposal as radioactive waste. However, to do so, it is necessary to bring its radioactivity down to sufficiently low levels. We have two possible goals: · Recycling (within the nuclear industry) for first wall and front blanket components. In that case, contact dose rate must be sufficiently low. · Clearance (release from nuclear regulatory control) for back blanket and backplate components. In that case, the clearance index must be below unity. In fact, for components less exposed to neutron activation, clearance may be reachable, after a conceivable period of decay. Maximum radionuclide concentrations in the alloys allowing their clearance were determined, using new IAEA Clearance Limits. For this purpose, also for less neutron-exposed structures, such as the back part of the blanket and the backplate, clearance is possible only if certain activation products are separated. As for recycling within the nuclear industry of first wall components, also for clearance it turns out that the development of isotope chemical separation techniques is interesting and necessary for our purposes. A suitable method for achieving the required substantial radioactivity reduction of activated V-Cr-Ti alloys is radiochemical extraction reprocessing, Such a technology, permitting to remove metallic activation products from spent materials, was developed and tested experimentally in Russia. Concerning clearance of less activated components, based on the estimated element distribution factors in the extraction and re-extraction processes, and computations, it was shown that the alloy components may be purified from the activation products, using this technology, down to an

  17. Recent activities on clearance in IAEA and clearance automatic laser inspection system (CLALIS)

    International Nuclear Information System (INIS)

    Hattori, Takatoshi; Sasaki, Michiya

    2005-01-01

    Exemption levels for bulk amounts of materials have been described in RS-G-1.7 published as a safety guide in IAEA on August 2004. In Japan, the Nuclear Safety Commission adopted the RS-G-1.7 values as Japanese clearance levels after the careful review of dose assessment results. After completing revises of regulatory laws in relation to clearance level, solid wastes from decommissioning and operating nuclear power plants will be targets of clearance inspection. In CRIEPI, Clearance Automatic Laser Inspection System (CLALIS) has been developed, which can give high reliability and objectivity to the measurement data. The CLALIS is a new monitoring system coupling with 3D laser shape measurement, Monte-Carlo calculation and gamma measurement techniques, which can keep a high accuracy in the measurement data using an automatic correction technique for self-shielding effects of metal waste itself and is expected to apply as a practical use in actual clearance inspections. (author)

  18. Radioimmunologic determination of hepatitis B antigen (HBsAG) in selected groups of persons and in special blood preparations

    Energy Technology Data Exchange (ETDEWEB)

    Lipsic, T; Geso, L [Clinic of Haematology and Blood Transfusion, Bratislava (Czechoslovakia)

    1978-06-30

    Presence of HBsAg was investigated by the RIA method in groups: exposed patients, blood donors, medical staff and different plasma preparations, namely: antihaemophilic cryoprotein (AHCp), Fibrinogen, I. Cohn's fraction and PPSB. 1789 samples of serum or converted material (plasma and its fractions) were investigated. In 405 cases AUSRIA-I method was used, the remaining 1384 cases were investigated by AUSRIA-II. Data are tabulated.

  19. Hepatitis B surface antigen (HBsAg) and core antigen (HBcAg) combine CpG oligodeoxynucletides as a novel therapeutic vaccine for chronic hepatitis B infection.

    Science.gov (United States)

    Li, Jianqiang; Ge, Jun; Ren, Sulin; Zhou, Tong; Sun, Ying; Sun, Honglin; Gu, Yue; Huang, Hongying; Xu, Zhenxing; Chen, Xiaoxiao; Xu, Xiaowei; Zhuang, Xiaoqian; Song, Cuiling; Jia, Fangmiao; Xu, Aiguo; Yin, Xiaojin; Du, Sean X

    2015-08-20

    Hepatitis B virus infection is a non-cytopathic hepatotropic virus which can lead to chronic liver disease and hepatocellular carcinoma. Traditional therapies fail to provide sustained control of viral replication and liver damage in most patients. As an alternative strategy, immunotherapeutic approaches have shown promising efficacy in the treatment of chronic hepatitis B patients. Here, we investigated the efficacy of a novel therapeutic vaccine formulation consisting of two HBV antigens, HBsAg and HBcAg, and CpG adjuvant. This vaccine formulation elicits forceful humoral responses directed against HBsAg/HBcAg, and promotes a Th1/Th2 balance response against HBsAg and a Th1-biased response against HBcAg in both C57BL/6 and HBV transgenic mice. Vigorous cellular immune response was also detected in HBV transgenic mice, for a significantly higher number of HBs/HBc-specific IFN-γ secreting CD4+ and CD8+ T cells was generated. Moreover, vaccinated mice elicited significantly intense in vivo CTL attack, reduced serum HBsAg level without causing liver damage in HBV transgenic mice. In summary, this study demonstrates a novel therapeutic vaccine with the potential to elicit vigorous humoral and cellular response, overcoming tolerance in HBV transgenic mice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Generic clearance values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2009-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document 'Safety Reports Series Nr 44' of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (author)

  1. Generic Clearance Values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2010-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on the one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document Safety Reports Series 44 of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (authors) [es

  2. HBsAg RIA QUICK and Anti-HBs RIA QUICK. Information of a new technique of radioimmunoassay of hepatitis B virus surface antigen and the corresponding antibody using kits by IMMUNO Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Kselikova, M; Urbankova, J

    1985-11-01

    With regard to the high sensitivity of HBsAg and anti-HBs detection using kits HBsAg RIA QUICK and Anti-HBs RIA QUICK, and with regard to the excellent technical set-up which substantially reduces demands on manual work and eliminates the need to equip the department with a rinser, and also with regard to the lower price as compared with similar kits by Abbott Co., the above mentioned two kits will be imported to Czechoslovakia.

  3. Changing serum levels of quantitative hepatitis B surface antigen and hepatitis B virus DNA in hepatitis B virus surface antigen carriers: A follow-up study of an elderly cohort

    Directory of Open Access Journals (Sweden)

    Yuan-Hung Kuo

    2015-02-01

    Full Text Available This study was to elucidate longitudinally quantitative changes of hepatitis B virus (HBV surface antigen (HBsAg and HBV DNA in elder HBsAg carriers in a community. Among 1002 residents screened for HBsAg in 2005, 405 responded to this follow-up study in 2010. Fifty-nine (14.6% were HBsAg carriers in 2005; HBsAg quantification and HBV DNA were measured. HBsAg quantification (cutoff 1600 IU/mL and HBV DNA (cutoff 2000 IU/mL were combined to stratify the participants between two screens. A total of 30 men and 29 women with a mean age of 63.9 ± 7.9 years were enrolled. Quantitative levels of HBsAg and HBV DNA were significantly correlated in 2005 (r = 0.509, p < 0.001 and 2010 (r = 0.777, p < 0.001. Concentrations of HBsAg (IU/mL significantly decreased from 2.2 ± 1.0 log in 2005 to 1.7 ± 1.5 log in 2010 (p < 0.001. The level of HBsAg was decreased in 48 (81.4% individuals and HBsAg was undetectable in eight (13.6%. The annual incidence of HBsAg clearance was 2.7%. These 59 HBsAg carriers in 2005 were divided into four groups: low HBsAg low HBV DNA (n = 32, high HBsAg low HBV DNA (n = 5, low HBsAg high HBV DNA (n = 12 and high HBsAg high HBV DNA (n = 10. All 32 individuals in the low HBsAg low HBV DNA group were still in that group in 2010, whereas only two of the high HBsAg high HBV DNA group became inactive. As with a younger cohort in hospital, HBsAg quantification was still well correlated with HBV DNA in elderly HBsAg carriers in the community. Lower levels of both HBsAg and HBV DNA might represent an inactive HBV infection.

  4. Lack of immune potentiation by complexing HBsAg in a heat-inactivated hepatitis B vaccine with antibody in hepatitis B immunoglobulin

    NARCIS (Netherlands)

    Lelie, P. N.; van Amelsfoort, P. J.; Martine de Groot, C. S.; Bakker, E.; Schaasberg, W.; Niessen, J. C.; Reesink, H. W.

    1989-01-01

    In a randomized, dose-response study among 305 health care workers, we examined whether the immunogenicity of a heat-inactivated hepatitis B vaccine could be enhanced when HBsAg was complexed by anti-HBs contained in hepatitis B immunoglobulin either at equivalent proportions or at 10-fold antigen

  5. Effect on HBs antigen clearance of addition of pegylated interferon alfa-2a to nucleos(t)ide analogue therapy versus nucleos(t)ide analogue therapy alone in patients with HBe antigen-negative chronic hepatitis B and sustained undetectable plasma hepatitis B virus DNA: a randomised, controlled, open-label trial.

    Science.gov (United States)

    Bourlière, Marc; Rabiega, Pascaline; Ganne-Carrie, Nathalie; Serfaty, Lawrence; Marcellin, Patrick; Barthe, Yoann; Thabut, Dominique; Guyader, Dominique; Hezode, Christophe; Picon, Magali; Causse, Xavier; Leroy, Vincent; Bronowicki, Jean Pierre; Carrieri, Patrizia; Riachi, Ghassan; Rosa, Isabelle; Attali, Pierre; Molina, Jean Michel; Bacq, Yannick; Tran, Albert; Grangé, Jean Didier; Zoulim, Fabien; Fontaine, Hélène; Alric, Laurent; Bertucci, Inga; Bouvier-Alias, Magali; Carrat, Fabrice

    2017-03-01

    Findings from uncontrolled studies suggest that addition of pegylated interferon in patients with HBe antigen (HBeAg)-negative chronic hepatitis B receiving nucleos(t)ide analogues with undetectable plasma hepatitis B virus (HBV) DNA might increase HBs antigen (HBsAg) clearance. We aimed to assess this strategy. In this randomised, controlled, open-label trial, we enrolled patients aged 18-75 years with HBeAg-negative chronic hepatitis B and documented negative HBV DNA while on stable nucleos(t)ide analogue regimens for at least 1 year from 30 hepatology tertiary care wards in France. Patients had to have an alanine aminotransferase concentration of less than or equal to five times the upper normal range, no hepatocellular carcinoma, and a serum α fetoprotein concentration of less than 50 ng/mL, normal dilated fundus oculi examination, and a negative pregnancy test in women. Patients with contraindications to pegylated interferon were not eligible. A centralised randomisation used computer-generated lists of random permuted blocks of four with stratification by HBsAg titres (sida et les hépatites virales (France Recherche Nord&sud Sida-vih Hepatites). Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A Study to Determine Clearance Levels of Radioactive Wastes in Kenya

    Energy Technology Data Exchange (ETDEWEB)

    Mukakaa, Zaphania O. [KAIST, Daejeon (Korea, Republic of); Kim, Sung Il [KINS, Daejeon (Korea, Republic of)

    2015-10-15

    RESRAD computer code model largely depends on numerous default values of the pathway analysis method based on the US geographical background. This could be the major reason as to why there exists some deviation between RESRAD code study results and the IAEA's generic clearance level values. If data on these three parameters was conclusive, there is a high probability that a true reflection of the clearance levels of the given radionuclides would be formulated. This might have been achieved with a lot of certainty because a true.

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Treatments and Therapies Airway Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. ... or caregiver. Older kids and adults can choose ACTs that they can do on their own. Share ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. Most are easy to ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage ... LEGACY GIFT Sponsor a Participant CF Climb CF Cycle for Life Great Strides Xtreme Hike Participate In ...

  12. Study on clearance system

    International Nuclear Information System (INIS)

    Onishi, Yuko; Miura, Hiroshi; Kawasaki, Satoru

    2011-01-01

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports NISA on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In reactor facilities, the bulk measurement technique or the statistical sampling measurement technique may be applied to large scale objects or concrete walls. In this study, the criteria of those techniques were examined. In uranium processing facilities, it is important to confirm surface state of the object in case of detecting alpha rays. The result of the examination about the influence of the surface rust in the uranium clearance measurement by the alpha ray measurement showed that the pollution was distributed in rust layer uniformly. This result will be reflected to the revision of the Ministerial Ordinance on Clearance in 2011FY. To develop a manual for unexpected incidents, the response procedure for an unexpected incident was prepared, including a response system. (author)

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast ... Facebook Twitter ...

  14. Evaluation of serum iohexol clearance for use in predicting carboplatin clearance in cats.

    Science.gov (United States)

    Bailey, Dennis B; Rassnick, Kenneth M; Prey, Joshua D; Dykes, Nathan L

    2009-09-01

    To determine whether a glomerular filtration rate (GFR) assay based on serum iohexol clearance can be used to predict carboplatin clearance in cats. 10 cats with tumors. GFR was measured concurrently by use of plasma clearance of technetium Tc 99m-labeled diethylenetriaminepentaacetic acid ((99m)Tc-DTPA) to yield GFR(99mTc-DTPA) and serum clearance of iohexol to yield GFR(Iohexol). A single dose of carboplatin was administered IV as a bolus. Dose was calculated by use of a target value for the area under the plasma platinum concentration-versus-time curve (AUC(Target)) and estimation of platinum clearance (CL(PT)) derived from GFR(99mTc-DTPA) as follows: dose = AUC(Target) x 2.6 x GFR(99mTc-DTPA) x body weight, where AUC(Target) is 2.75 min.mg.mL(-1). Plasma platinum concentrations were measured via atomic absorption spectrophotometry. Values for GFR(99mTc-DTPA) and GFR(Iohexol) were compared by use of least-squares regression and Bland-Altman analysis. Least-squares regression was used to determine whether CL(PT) could be predicted from GFR(99mTc-DTPA) or GFR(Iohexol) (or both). GFR(99mTc-DTPA) and GFR(Iohexol) were strongly correlated (r = 0.90), but GFR(Iohexol) values were significantly larger by a factor of approximately 1.4. Platinum clearance had a significant linear relationship to GFR(99mTc-DTPA) (CL(PT) = 2.5 x GFR(99mTc-DTPA)) and to GFR(Iohexol) (CL(PT) = [1.3 x GFR(Iohexol)] + 1.4). In cats, serum iohexol clearance was an accurate predictor of CL(PT) and can be used to calculate the carboplatin dose as follows: dose = AUC(Target) x ([1.3 x GFR(Iohexol)] + 1.4) x body weight.

  15. The variability of hepatitis B envelope is associated with HBs antigen persistence in either chronic or acute HBV genotype A infection.

    Science.gov (United States)

    Eschlimann, Marine; Malvé, Brice; Velay, Aurélie; Fenaux, Honorine; Berger, Sibel; Frippiat, Jean-Pol; Zoulim, Fabien; Bensenane, Mouni; Bronowicki, Jean-Pierre; Goehringer, François; May, Thierry; Jeulin, Hélène; Schvoerer, Evelyne

    2017-09-01

    More than 240 million people are chronically infected by hepatitis B virus (HBV) worldwide. Envelope proteins play a crucial role in viral cellular entry and immune recognition. The loss of HBs antigen (HBsAg) correlated with a good clinical prognosis is rarely achieved with or without treatment (3-16%). HBV envelope variability was investigated according to HBsAg persistence. The cohort consisted of 15 HBV genotype A-infected patients divided into "resolvers", with HBsAg clearance, and "non-resolvers", with HBsAg persistence and in subgroups: acute (n=5, AHBV) or chronic infection (n=4, CHBV) and HBV/HIV coinfection (n=6, CHBV/HIV). HBV S and preS sequences were studied by direct and ultra-deep sequencing. Amino acid sequences were analyzed with bioinformatics for predicted antigenicity. In S gene, the complexity was lower in AHBV than in chronic-infected patients (p=0.046). Major mutations, detected using direct sequencing, were more frequent in AHBV developing chronicity (p=0.01) than in AHBV resolvers. In the Major Hydrophilic Region, more frequent mutations were observed in non-resolvers versus resolvers (p=0.047) and non-resolvers tended to have more haplotypes with a reduced predicted antigenicity (p=0.07). Most of the mutations in preS/S region were found rather in epitopic than in non-epitopic areas (p=0.025). Interestingly, the mutation sY161F found in 3/8 non-resolvers was associated with a decrease in predicted antigenicity (28%; AnTheProt). HBsAg persistence was correlated with mutations and deletions in areas playing a key role in immune recognition. These data suggest that variability in HBV envelope could favor immune escape in various clinical settings of HBV genotype A-infected patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A simple method for the verification of clearance levels for non-radioactive solid waste

    International Nuclear Information System (INIS)

    Holland, B.

    1997-01-01

    ANSTO's radiopharmaceutical production laboratories generate 25 m 3 of solid waste per month. Most of this waste is not radioactive. Up until recently the non-radioactive waste was cleared from the controlled area and stored for 10 halflives prior to disposal as normal solid refuse. To eliminate the storage and ''double handling'' of the large quantities of non-radioactive waste a simple clearance method was devised to allow direct disposal. This paper describes how clearance levels were determined. Here the term ''clearance level'' is used as a general term for the release of material regardless of whether it was previously subject to regulatory control. This contrasts with the IAEA definition of a clearance level and highlights a potential problem with the implementation of exemption levels to keep material out of regulatory control and the use of clearance levels to allow removal of materials from regulatory control. Several common hand held contamination monitors were tested to determine their limits of detection and ability to meet these clearance levels. The clearance method includes waste segregation and size limitation features to ensure the waste is monitored in a consistent manner, compatible with the limits of detection. The clearance levels achieved were subsequently found to be compatible with some of the unconditional clearance levels in IAEA-TECDOC-855 and the measurement method also meets the required features of that document. The ANSTO non-radioactive waste clearance system has been in operation for more than 12 months and has proved simple and effective to operate. Approximately 12m 3 of the solid waste is now been treated directly as normal solid refuse. This paper describes the ANSTO clearance system, the contamination monitor tests and details practical problems associated with the direct monitoring of solid waste, including averaging of the activity in the package. The paper also briefly highlights the potential problem with the use of

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... and Their Families When There's More Than One Person With CF in the Same School Daily Life ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Team Your cystic fibrosis care team includes a group of CF health care professionals who partner with ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  19. NUMERICAL SIMULATIONS FOR THE CASE OF RIGID ROTATING KINEMATIC COUPLING WITH BIG CLEARANCE

    Directory of Open Access Journals (Sweden)

    Jan-Cristian GRIGORE

    2010-10-01

    Full Text Available In this paper an algorithm based on [1] [2] are numerical simulations, achieving generalized coordinates of motion, positions, speeds of a rigid rotating kinematic coupling with big clearance in joint, case without friction

  20. Clearance Kinetics and Clearance Routes of Molecules From the Suprachoroidal Space After Microneedle Injection.

    Science.gov (United States)

    Chiang, Bryce; Wang, Ke; Ethier, C Ross; Prausnitz, Mark R

    2017-01-01

    To determine clearance kinetics and routes of clearance of molecules from the suprachoroidal space (SCS) of live New Zealand White rabbits. Suprachoroidal space collapse rate and pressure changes after microneedle injection into SCS were determined. Fluorescent fundus images were acquired to determine clearance rates of molecules ranging in size from 332 Da to 2 MDa. Microneedle injections of fluorescein were performed, and samples were taken from various sites over time to determine amount of fluorescein exiting the eye. Clearance transport was modeled theoretically and compared with experimental data. After injection, pressures in SCS and vitreous humor spiked and returned to baseline within 20 minutes; there was no difference between these two pressures. Suprachoroidal space collapse occurred within 40 minutes. One hour after fluorescein injection, 46% of fluorescein was still present in the eye, 15% had transported across sclera, 6% had been cleared by choroidal vasculature, and 4% had exited via leakage pathways. Characteristic clearance time increased in proportion with molecular radius, but total clearance of 2 MDa FITC-dextran was significantly slower (21 days) than smaller molecules. These data generally agreed with predictions from a theoretical model of molecular transport. Guided by experimental data in the context of model predictions, molecular clearance from SCS occurred in three regimes: (1) on a time scale of approximately 10 minutes, fluid and molecules exited SCS by diffusion into sclera and choroid, and by pressure-driven reflux via transscleral leakage sites; (2) in approximately 1 hour, molecules cleared from choroid by blood flow; and (3) in 1 to 10 hours, molecules cleared from sclera by diffusion and convection.

  1. Study on clearance system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports Nuclear Regulatory Agency on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In uranium processing facilities, simulation sources emitting alpha-rays is used in a validity confirmation examination of the measuring equipment. In this study, these sources were examined by measuring alpha and beta spectra to evaluate the applicability and problem of these sources. In addition, the measuring method detecting gamma-rays was examined. This method can be applied to complicated objects. As a part to develop a manual for unexpected incidents in clearance system, a quick method for measurement of Strontium 90 was examined. In addition, the measuring methods for the judgment of the influence of fallout and for NR (Non-Radioactive) confirmation were examined. (author)

  2. Thickness and clearance visualization based on distance field of 3D objects

    Directory of Open Access Journals (Sweden)

    Masatomo Inui

    2015-07-01

    Full Text Available This paper proposes a novel method for visualizing the thickness and clearance of 3D objects in a polyhedral representation. The proposed method uses the distance field of the objects in the visualization. A parallel algorithm is developed for constructing the distance field of polyhedral objects using the GPU. The distance between a voxel and the surface polygons of the model is computed many times in the distance field construction. Similar sets of polygons are usually selected as close polygons for close voxels. By using this spatial coherence, a parallel algorithm is designed to compute the distances between a cluster of close voxels and the polygons selected by the culling operation so that the fast shared memory mechanism of the GPU can be fully utilized. The thickness/clearance of the objects is visualized by distributing points on the visible surfaces of the objects and painting them with a unique color corresponding to the thickness/clearance values at those points. A modified ray casting method is developed for computing the thickness/clearance using the distance field of the objects. A system based on these algorithms can compute the distance field of complex objects within a few minutes for most cases. After the distance field construction, thickness/clearance visualization at a near interactive rate is achieved.

  3. Human immunodeficiency virus (HIV) seropositivity and hepatitis B surface antigenemia (HBSAG) among blood donors in Benin city, Edo state, Nigeria.

    Science.gov (United States)

    Umolu, Patience Idia; Okoror, Lawrence Ehis; Orhue, Philip

    2005-03-01

    Human Immunodeficiency Virus and Hepatitis B virus are blood borne pathogens that can be transmitted through blood transfusion and could pose a huge problem in areas where mechanisms of ensuring blood safety are suspect. This study became necessary in a population where most of the blood for transfusion is from commercial blood donors. A total of 130 donors comprising 120 commercial donors and 10 voluntary donors were tested for antibodies to human immunodeficiency virus and hepatitis B surface antigen in Benin city using Immunocomb HIV - 1 and 2 Biospot kit and Quimica Clinica Aplicada direct latex agglutination method respectively. Thirteen (10%) samples were HIV seropositive and 7(5.8%) were HBsAg positive. The age bracket 18 - 25years had the highest numbers of donors and also had the highest number of HBsAg positive cases (7.8%) while the age group 29 - 38years had highest number of HIV seropositive cases. High prevalence of HIV antibodies and Hepatitis B surface antigen was found among commercial blood donors. Appropriate and compulsory screening of blood donors using sensitive methods, must be ensured to prevent post transfusion hepatitis and HIV.

  4. Human-in-the-Loop Assessment of Alternative Clearances in Interval Management Arrival Operations

    Science.gov (United States)

    Baxley, Brian T.; Wilson, Sara R.; Swieringa, Kurt A.; Johnson, William C.; Roper, Roy D.; Hubbs, Clay E.; Goess, Paul A.; Shay, Richard F.

    2016-01-01

    Interval Management Alternative Clearances (IMAC) was a human-in-the-loop simulation experiment conducted to explore the Air Traffic Management (ATM) Technology Demonstration (ATD-1) Concept of Operations (ConOps), which combines advanced arrival scheduling, controller decision support tools, and aircraft avionics to enable multiple time deconflicted, efficient arrival streams into a high-density terminal airspace. Interval Management (IM) is designed to support the ATD-1 concept by having an "Ownship" (IM-capable) aircraft achieve or maintain a specific time or distance behind a "Target" (preceding) aircraft. The IM software uses IM clearance information and the Ownship data (route of flight, current location, and wind) entered by the flight crew, and the Target aircraft's Automatic Dependent Surveillance-Broadcast state data, to calculate the airspeed necessary for the IM-equipped aircraft to achieve or maintain the assigned spacing goal.

  5. Limitations of regional myocardial thallium clearance for identification of disease in individual coronary arteries

    International Nuclear Information System (INIS)

    Becker, L.C.; Rogers, W.J. Jr.; Links, J.M.; Corn, C.

    1989-01-01

    The purpose of this study was to critically evaluate the usefulness of postexercise regional myocardial thallium-201 clearance for identifying disease in individual coronary arteries. Exercise and redistribution planar imaging studies were performed in 114 subjects, including 19 normal volunteers and 95 patients undergoing cardiac catheterization (70 with and 25 without greater than or equal to 50% narrowing in one or more coronary arteries). Thallium clearance was measured from predefined myocardial regions corresponding to the left anterior descending, left circumflex and right coronary arteries and was expressed as the percent decrease in activity at 4 h, assuming monoexponential clearance. In regions perfused by a normal or insignificantly diseased coronary artery, mean 4 h clearance was 58.9 +/- 9.4% for normal volunteers, 43.1 +/- 15.5% for catheterized patients without coronary artery disease and 36.3 +/- 24.9% for catheterized patients with coronary artery disease (p less than 0.001 patients with coronary artery disease versus normal volunteers). Clearance from normal regions was significantly associated with two measures of exercise performance: percent of predicted maximal heart rate achieved (r = 0.49) and exercise duration (r = 0.35). In regions perfused by a stenotic coronary artery, mean clearance was lower (31.1 +/- 19.8%) but was not significantly different from that in normal regions in the same patients. Clearance from diseased regions was also associated with maximal exercise heart rate (r = 0.28) and exercise duration (r = 0.41), but not with percent coronary artery stenosis (r = 0.02). After taking exercise performance into account, the number of diseased vessels or the presence or absence of disease in a given vessel had little influence on regional thallium clearance

  6. HDV Seroprevalence in HBsAg Positive Patients

    International Nuclear Information System (INIS)

    Abbasi, A.; Bhutto, A. R.; Mahmood, K.; Butt, N.

    2014-01-01

    Objective: To find out the frequency of HDV seroprevalence and the demographic characteristics or HBsAg-HDV positive patients. Study Design: Cross-sectional analytical study. Place and Duration of Study: Jinnah Postgraduate Medical Centre and Civil Hospital, Medical Unit-III, Karachi, from March 2007 to April 2011. Methodology: Patients with positive HBsAg were included in the study. Those having co-infection with HCV or HIV, autoimmune hepatitis, alcoholic hepatitis, Wilson's disease and haemochromatosis were excluded. After detailed history and physical examination all the patients underwent laboratory workup including complete blood count, liver function test, viral profile (HAV, HCV, HIV and anti-HDV) and prothrombin time. While in selected patients, HBc (core) antibodies, ultrasound abdomen, serum iron profile, ANA and liver biopsy were also carried out whenever needed to establish a clinical stage of liver disease. Results: There were 374 patients with 266 (71.1%) males and 108 (28.9%) females with overall mean age of 31.64 +- 8.66 years. Overall frequency of anti-HDV antibodies positivity was found in 28.1% (n = 105) patients. HDV seropositivity was slightly more prevalent in males as compared to females (28.57% vs. 26.57%). HDV seropositivity frequency was significantly higher in patients who presented with acute hepatitis/hepatic failure as compared to other clinical diagnoses (p = 0.027) and in those sub-sets of patients who had raised ALT levels (p = 0.012). Conclusion: There was a high frequency of HDV seropositivity in the studied population particularly in males with acute hepatitis or hepatic failure, having raised ALT levels. The emphasis should be on preventive measures taken by other countries to reduce the prevalence of these treatment challenging infections. (author)

  7. Clearance of psoriasis: the impact of private versus public insurance.

    Science.gov (United States)

    Buzney, Catherine D; Peterman, Caitlin; Saraiya, Ami; Au, Shiu-chung; Dumont, Nicole; Mansfield, Ryan; Gottlieb, Alice B

    2015-02-01

    Psoriasis treatments and therapeutic response as they relate to private versus public patient insurance in the United States have not yet been reviewed. Improved understanding could clarify factors challenging optimal psoriasis management and offer insight for dermatologists treating psoriasis within our healthcare system. 258 subjects were included from a database of psoriasis patients seen at Tufts Medical Center (Boston, MA) during 2008-2014. Insurance was classified as primarily private or public (Medicare or MassHealth/Medicaid). Patients required a minimum of two consecutive visits per treatment and at least 8 weeks within one of four treatment categories: biologics, oral systemics/ phototherapy, combined biologics and oral systemics/phototherapy, or topicals only. Primary endpoint was the Simple-Measure for Assessing Psoriasis Activity (S-MAPA) calculated by multiplying Physician Global Assessment by Body Surface Area. S-MAPAMAPA improvement from baseline, and total drugs used per treatment course (“drug-switching”). 80.2% (n=207) and 19.8% (n=51) had primarily private and public insurance, respectively. 69.6% with private insurance were prescribed biologics versus 66.7% (public insurance) (P=0.689). 54% (private) versus 49% (public) achieved clearance (P=0.514). However, S-MAPA decreased 78.35% from baseline in those with private insurance compared to 61.48% (public) (P=0.036). On average, privately insured patients used at least twice as many same-category treatments, most commonly biologics, than publicly insured individuals (P=0.003). Drug-switching was significantly associated with clearance (P=0.024). Multivariate analysis demonstrated no significant differences in prescribed treatment categories, drug efficacy, clearance, S-MAPA, or drugswitching with respect to patient age. Treatment categories were comparably prescribed between insurance subgroups. However, privately insured patients achieved significantly greater degrees of clearance and

  8. Clearance of materials from accelerator facilities

    Directory of Open Access Journals (Sweden)

    Rokni Sayed H.

    2017-01-01

    Full Text Available A new Technical Standard that supports the clearance of materials and equipment (personal property from U.S. Department of Energy (DOE accelerator facilities has been developed. The Standard focuses on personal property that has the potential to be radiologically impacted by accelerator operations. It addresses material clearance programs and protocols for off-site releases without restriction on use. Common metals with potential volumetric activation are of main interest with technical bases provided in Appendices of the Standard. The clearance protocols in the Standard include three elements: 1 clearance criteria, 2 process knowledge, and 3 measurement methods. This paper presents the technical aspects of the new Standard, discusses operational experience gained in clearance of materials and equipment from several accelerator facilities at SLAC and examples as to how this Standard can be applied to benefit the entirety of the DOE Accelerator Complex.

  9. Clearance and release from control - An international perspective

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    This paper tries to give an overview of the clearance, or release from regulatory control, on an international scale, including some of those countries where clearance has become or is about to become vital for D and D. The emphasis lies on the impact of clearance, and in particular of differences between clearance levels of various countries, on D and D. Relevance of clearance for D and D of nuclear installations Clearance is an essential part of waste management (or more general, material management) in nuclear installations, and in particular during the decommissioning phase where waste streams continues to arise. Of course, the relevance of clearance in a particular country depends on a number of factors, like: availability of a final repository and its price; prevailing decommissioning strategy; number of nuclear installations reaching decommissioning phase. This small selection of reasons why clearance may be of varying importance for different countries may already suffice to illustrate why up to now clearance has been developed and implemented in quite different ways. If one thinks of additional reasons that may influence clearance, like politics, the public opinion, availability of funds etc., the situation becomes even more complex. It is, however safe to draw the conclusion that countries with a certain number of nuclear installations which have been or will soon be shut down or which are already in the decommissioning phase will need to implement provisions for clearance. This has indeed been the case with countries like the UK, Germany, the USA, Sweden, and a number of others. It is not essential for clearance levels to be exactly equal between various countries. They may differ as long as the difference is not too large, e.g. the values fall into the same order of magnitude. This is the reason why for example Germany has no problems with clearance levels which differ from the EU recommendation RP 122 partially adopted in a number of EU countries

  10. Perspectives on hypertension outcomes after single-stage clearance of a complete staghorn renal calculus

    Directory of Open Access Journals (Sweden)

    Ranjit Chaudhary

    2017-01-01

    Full Text Available A 55-year-old male presented, in June 2013, with left flank pain. Investigations revealed a complete staghorn stone. He had undergone two sittings of extracorporeal shock wave lithotripsy (ESWL in 2008 for left renal stone. One year subsequent to this, he was diagnosed with hypertension and diabetes. The management of complete staghorn stones in a single sitting is a difficult proposition. Percutaneous nephrolithotomy (PCNL is the gold standard to manage such stones. The patient was subjected to PCNL, and complete clearance was achieved in one sitting. On one-year follow-up, there was a significant reduction in blood pressure (BP and better glycemic control. Although there are several reports where hypertension has been reported after multiple sittings of ESWL, whether ESWL contributed to the genesis of hypertension and diabetes in this patient or it was simply incidental, cannot be stated with certainty. There was a significant reduction in the BP after complete stone removal, but there is uncertainty over the effect of total clearance of renal stones on hypertension, and we need to await the results of more controlled trials studying this phenomenon. A better glycemic control was perhaps achieved secondary to the eradication of recurrent urinary tract infections due to complete stone clearance.

  11. Technetium-99m mercaptoacetyltriglycine clearance values in children with minimal renal disease: can a normal range be determined?

    International Nuclear Information System (INIS)

    Meyer, G.; Hahn, K.; Piepsz, A.; Kolinska, J.; Lepej, J.; Sixt, R.

    1998-01-01

    Use of technetium-99m labelled mercaptoacetyltriglycine ( 99m Tc-MAG3) simplifies and improves the quantification of renal clearance in children by virtue of its permanent availability, good imaging properties and low radiation exposure. Due to the lack of reference values for 99m Tc-MAG3 clearance in children, the Paediatric Task Group of the EANM initiated a multicentre study to evaluate 99m Tc-MAG3 clearance values in children with minimal renal disease. One hundred and twenty-five children aged between 12 months and 17 years, classified as renally healthy using defined diagnostic criteria, were included in the study. 99m Tc-MAG3 clearance was calculated using an algorithm on the basis of a single blood sample taken at any time between 30 and 40 min after tracer injection. In addition, the absolute 99m -Tc-MAG3 clearance values were normalized to body surface area. For further evaluation the children were classified into several groups according to age. There was a continuous increase in non-corrected 99m Tc-MAG3 clearance values from the age of 1 year up to the age of 17 years (mean value 8 years: 208±66 ml/min). Normal clearance values for adults were achieved by the age of 8 years. Analysis of the relationship between non-corrected clearance and age yielded a correlation coefficient of r=0.7. When these absolute clearance values were normalized to body surface area, we found nearly constant clearance values for all age groups, with a mean clearance value of 315±114 ml/min x 1.73 m 2 . The correlation coefficient for the relationship between normalized clearance and age was r=0.28. In conclusion, the clearance of 99m Tc-MAG3 increases continuously throughout childhood into adolescence due to the maturation and growth of the kidney. After normalization of the absolute clearance to body surface area, no correlation between clearance and age could be proven. (orig.)

  12. Diagnostic value of renal clearance techniques using iodo-hippuran /sup 131/I and /sup 99m/-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Hoer, G [Technische Univ. Muenchen (Germany, F.R.). Nuklearmedizinische Klinik und Poliklinik

    1976-01-01

    Methods and clinical indications of divided renal clearance determination using /sup 131/I-hippuran are presented and their value as a diagnostic tool in urology is shown by two case reports. For quantitative assessment of renal function we prefer the whole body clearance (with partial shielding of kidneys and bladder) which obviates the necessity of the theoretical assumption of compartmental distribution of radiopharmaceuticals. Using simplified clearance techniques only based on analysis of plasma disappearance curves (slope clearance one- and two-compartment model), clinically useful results are also obtainable, especially in follow up studies. The evaluation of tubular and glomerular kidney function by simultaneous application of /sup 131/I-hippuran and sup(99m)Tc-DTPA is suitable for estimation of filtration fraction in patients with urological and nephrological diseases. Even with regard to therapy and follow up studies of urinary tract tuberculosis, remarkable dignostic informations may be achieved.

  13. Rational customs clearance technology choice

    OpenAIRE

    Shramenko, N.; Andriets, V.

    2008-01-01

    Issues concerning cargo delivery efficiencyincrease by choice of rational customs clearance technology have been considered. Three possible variants of customs clearance andmethods which allow to define the most rational version of cargo delivery in international road communication based on main efficiency criteria for definite distance have been presented.

  14. 7 CFR 1927.55 - Title clearance services.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS TITLE CLEARANCE AND LOAN CLOSING Real Estate Title Clearance and Loan Closing § 1927.55 Title clearance services. (a) Responsibilities of closing agents. Services to be provided to the agency and the borrower by a closing agent in connection with the transaction vary depending on whether a title insurance...

  15. Relationship between silicon concentration and creatinine clearance

    International Nuclear Information System (INIS)

    Miura, Y.; Nakai, K.; Itoh, C.; Horikiri, J.; Sera, K.; Sato, M.

    1998-01-01

    Silicon levels in dialysis patients are markedly increasing. Using PIXE we determined the relationship between silicon concentration and creatinine clearance in 30 samples. Urine silicon concentration were significantly correlated to creatinine clearance (p<0.001). And also serum silicon concentration were significantly correlated to creatinine clearance (p<0.0001). (author)

  16. Compressor airfoil tip clearance optimization system

    Science.gov (United States)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary. During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.

  17. Noninvasive determination of individual renal clearance

    International Nuclear Information System (INIS)

    Chanard, J.; Brunois, J.P.; Ruiz, J.C.; Assailly, J.

    1980-01-01

    A noninvasive method for measurement of individual renal clearance is presented, based on analysis of the early rise of the kidneys' time-activity curves after injection of an appropriate tracer ( 131 I-ortho-iodohippurate for tubular function or 111 In DTPA for glomerular clearance). The analysis is based on the assumption that an insignificant amount of tracer leaves the kidney during the first few moments following injection. Therefore, the kidney activity during this period is directly proportional to the integral of the blood (heart) activity. After blood background subtraction, the linear correlation between the early part of the renogram and the corresponding blood integral activity curve allows calculation of an angular coefficient. The ratio of these coefficients calculated for each kidney is proportional to the ratio of the individual clearances. The latter are calculated from the total clearance simultaneously measured using a simplified method without urine collection. In control subjects with normal renal function individual renal clearances were not significantly different. In uninephrectomized patients a precision of 5% in calculating individual clearance was estimated from data recorded at the level of the remaining kidney. In patients with functional asymmetry, results were compared with 197 HgCl 2 quantitative renal fixation. A linear correlation was found (r = 0.95). The method we propose seems valuable for clinical investigation and allows sequential measurements. (orig.)

  18. Calculation of the clearance requirements for the development of a hemodialysis-based wearable artificial kidney.

    Science.gov (United States)

    Kim, Dong Ki; Lee, Jung Chan; Lee, Hajeong; Joo, Kwon Wook; Oh, Kook-Hwan; Kim, Yon Su; Yoon, Hyung-Jin; Kim, Hee Chan

    2016-04-01

    Wearable artificial kidney (WAK) has been considered an alternative to standard hemodialysis (HD) for many years. Although various novel WAK systems have been recently developed for use in clinical applications, the target performance or standard dose of dialysis has not yet been determined. To calculate the appropriate clearance for a HD-based WAK system for the treatment of patients with end-stage renal disease with various dialysis conditions, a classic variable-volume two-compartment kinetic model was used to simulate an anuric patient with variable target time-averaged creatinine concentration (TAC), daily water intake volume, daily dialysis pause time, and patient body weight. A 70-kg anuric patient with a HD-based WAK system operating for 24 h required dialysis clearances of creatinine of at least 100, 50, and 25 mL/min to achieve TACs of 1.0, 2.0, and 4.0 mg/dL, respectively. The daily water intake volume did not affect the clearance required for dialysis under various conditions. As the pause time per day for the dialysis increased, higher dialysis clearances were required to maintain the target TAC. The present study provided theoretical dialysis doses for an HD-based WAK system to achieve various target TACs through relevant mathematical kinetic modeling. The theoretical results may contribute to the determination of the technical specifications required for the development of a WAK system. © 2015 The Authors. Hemodialysis International published by Wiley Periodicals, Inc. on behalf of International Society for Hemodialysis.

  19. [Relationship between HBeAg from HBsAg positive mothers and regulatory T cells in neonates and its influence on HBV intrauterine transmission].

    Science.gov (United States)

    Hao, H Y; Yang, Z Q; Xu, X X; Wang, X F; Wang, B; Shi, X H; Fu, Z D; Wang, B; Wang, S P

    2017-10-10

    Objective: To explore the relationship between HBeAg in HBsAg positive mothers and CD(4)(+)CD(25)(+) Foxp3 (+)regulatory T cells (Treg) in newborns, as well as how they would influence the increasing risk on HBV intrauterine transmission. Methods: We collected information on general demographic characteristics and delivery on 270 HBsAg positive mothers and their newborns from the Third People's Hospital of Taiyuan. Fluorescence quantitative polymerase chain reaction (FQ-PCR) and chemiluminescence immunoassay (CLIA) were used to detect HBV DNA and HBV serological markers in peripheral blood from both mothers and neonates. The expression of Treg and other immune cells in peripheral blood of neonates were detected with flow cytometry (FCM). Results: Maternal HBeAg positive rates were associated with an increased risk of intrauterine transmission ( OR =4.08, 95 %CI : 1.89-8.82). Rates of Treg in newborns born to HBsAg-positive mothers were higher than that of the negative group ( Z =2.29, P =0.022). Each pair of the subjects was assigned to five different groups according to the HBeAg titers of mothers. Frequencies of both Treg and HBeAg in newborns and HBV DNA in mothers between the above said 5 groups showed similar trends of changing patterns and the differences between groups were statistically significant(χ(2)=18.73, P mother's HBeAg titers were positively related to the percentage of Treg in their newborns ( r(s) =0.19, P =0.039). In addition, the frequencies of Treg were negatively correlated with pDC and CD(4)(+) T cell in their newborns ( r(s) =-0.21, P =0.017; r(s) =-0.23, P =0.009). Conclusion: HBeAg from HBsAg positive mothers might have inhibited the function of neonatal DC cells and T cells to reduce the immune response to HBV by up-regulating the proportion of Treg and finally increased the risk of HBV intrauterine transmission.

  20. Integrated viral clearance strategies-reflecting on the present, projecting to the future.

    Science.gov (United States)

    Roush, David J

    2018-01-20

    Viral clearance and inactivation are critical steps in ensuring the safety of biological products derived from mammalian cell culture and are a component of an adventitious agent control strategy which spans both upstream and downstream processes. Although these approaches have been sufficient to support the development of biologics to date, the empirical and semi-quantitative nature of the approach leaves some potential gaps. For example, the concept of performing a quantitative risk assessment for the downstream components of virus safety was introduced in ICH Q5A for XMuLV. An ideal future state would be to perform a similar quantitative risk assessment for a range of viruses based on an assessment of potential virus risk in both upstream and downstream processes. This assessment combined with an integrated control strategy (including monitoring) would be extremely beneficial in minimizing potential adventitious agent risks. Significant progress has been achieved towards this goal in the last several years including recent advances in quantification of virus sequences in cell banks (ADVTIG), development of truly modular or generic viral clearance claims for specific unit operations, enhanced controls of upstream media (HTST/nanofiltration) and the use of RVLP for in-process monitoring. The recent shift towards continuous processing has the potential to enhance the criticality of in-line monitoring and the complexity of viral clearance and inactivation (owing to a wide range of potential 'worst case' viral clearance scenarios). However, gaps exist in, firstly, the ability to quantify potential virus risk levels in process streams in real-time, secondly, mechanistic understanding of virus/chromatography media interactions, and thirdly, mechanistic understanding of virus/filter interactions. Some new technologies may also need to be developed to allow for real-time confirmation of virus inactivation and clearance to support process development (both batch and

  1. Importance of radioimmunoassays (HBsAg, HBsAb and HBcAb) for reducing the risk of hepatitis B transfer by blood

    International Nuclear Information System (INIS)

    Novak, J.; Kselikova, M.

    1979-01-01

    The principles are reported of the radioimmunoanalytical assay of the hepatitis B surface antigen, antibodies against this antigen which constitute immunologically indirect evidence, and antibodies against the nucleus of Dane's particles, which is circumstantial immunological evidence. The results obtained by radioimmunoassay are compared with those obtained by enzyme immunoassay. The results are presented obtained during the investigations of a total of 79 individuals, blood donors, health workers, and haemodialytic patients. In the whole group the hepatitis B surface antigen was proved by radioimmunoassay in 54%, by enzyme immunoassay in 47%; the antibody against the hepatitis B surface antigen in 19%; the antibody against the nucleus of the hepatitis B virus showed the largest proportion 75%. In 6.3% radioimmunoassay showed symptoms all three of hepatitis B, i.e., the surface antigen, the antibody against it, and the antibody against the hepatitis B virus nucleus; the correlation of the three symptoms is shown. The presence of HBsAg, HBsAb, and HBcAb is believed to be a contraindication of blood taking for routine purposes; the disappearance of HBsAg for a longer time may justify the re-inclusion among blood donors; the presence of HBsAb and HBcAb does not preclude the preparation of the plasma from such blood for the production of a specific anti-HBs immunoglobulin. (author)

  2. A model of clearance rate regulation in mussels

    Science.gov (United States)

    Fréchette, Marcel

    2012-10-01

    Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.

  3. Predicting Human Clearance of OATP substrates using Cynomolgus monkey: In vitro-in vivo scaling of hepatic uptake clearance.

    Science.gov (United States)

    de Bruyn, Tom; Ufuk, Ayse; Cantrill, Carina; Kosa, Rachel E; Bi, Yi-An; Niosi, Mark; Modi, Sweta; Rodrigues, A David; Tremaine, Larry M; Varma, Manthena Vs; Galetin, Aleksandra; Houston, J Brian

    2018-05-02

    This work explores the utility of the cynomolgus monkey as a preclinical model to predict hepatic uptake clearance mediated by organic anion transporting polypeptide (OATP) transporters. Nine OATP substrates (rosuvastatin, pravastatin, repaglinide, fexofenadine, cerivastatin, telmisartan, pitavastatin, bosentan and valsartan) were investigated in plated cynomolgus monkey and human hepatocytes. Total uptake clearance and passive diffusion were measured in vitro from initial rates in the absence and presence of the OATP inhibitor rifamycin SV, respectively. Total uptake clearance values in plated hepatocytes ranged over three orders of magnitude in both species with a similar rank order and good agreement in the relative contribution of active transport to total uptake between cynomolgus monkey and human. In vivo hepatic clearance for these nine drugs was determined in cynomolgus monkey after intravenous dosing. Hepatic clearances showed a similar range to human parameters and good predictions from respective hepatocyte parameters (with 2.7 and 3.8-fold bias on average, respectively). The use of cross species empirical scaling factors (based on either dataset average or individual drug scaling factor from cynomolgus monkey data) improved prediction (less bias, better concordance) of human hepatic clearance from human hepatocyte data alone. In vitro intracellular binding in hepatocytes also correlated well between species. It is concluded that the minimal species differences observed for the current dataset between cynomolgus monkey and human hepatocyte uptake, both in vitro and in vivo, support future use of this preclinical model to delineate drug hepatic uptake and enable prediction of human in vivo intrinsic hepatic clearance. The American Society for Pharmacology and Experimental Therapeutics.

  4. 48 CFR 801.602-76 - Business clearance review.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Business clearance review... GENERAL DEPARTMENT OF VETERANS AFFAIRS ACQUISITION REGULATION SYSTEM Career Development, Contracting Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a...

  5. Estimation of 131I hippuran clearance during pregnancy

    International Nuclear Information System (INIS)

    Voigt, R.; Stoll, W.; Zenner, I.; Arndt, J.; Friedrich-Schiller-Univ., Jena

    1979-01-01

    Changes in 131 I hippuran clearance were estimated by a non-catheter method, as well as total clearance and clearance of each kidney, in 43 women at various stages of pregnancy and in 13 non-pregnant women who were not using hormonal contraceptives. The results are demonstrated in graph form. The methods used are described in detail. The procedure for determining clearance in separate kidneys is indicated. It was found that clearance values increased up to the 35th and 26th weeks of pregnancy. The difference between the sides that were found corresponds with the previously known difference in the function of the right and left kidneys and ureters. (orig.) [de

  6. Improved drainage with active chest tube clearance.

    Science.gov (United States)

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Luteolin-7-O-Glucoside Present in Lettuce Extracts Inhibits Hepatitis B Surface Antigen Production and Viral Replication by Human Hepatoma Cells in Vitro

    Directory of Open Access Journals (Sweden)

    Xiao-Xian Cui

    2017-12-01

    Full Text Available Hepatitis B virus (HBV infection is endemic in Asia and chronic hepatitis B (CHB is a major public health issue worldwide. Current treatment strategies for CHB are not satisfactory as they induce a low rate of hepatitis B surface antigen (HBsAg loss. Extracts were prepared from lettuce hydroponically cultivated in solutions containing glycine or nitrate as nitrogen sources. The lettuce extracts exerted potent anti-HBV effects in HepG2 cell lines in vitro, including significant HBsAg inhibition, HBV replication and transcription inhibition, without exerting cytotoxic effects. When used in combination interferon-alpha 2b (IFNα-2b or lamivudine (3TC, the lettuce extracts synergistically inhibited HBsAg expression and HBV replication. By using differential metabolomics analysis, Luteolin-7-O-glucoside was identified and confirmed as a functional component of the lettuce extracts and exhibited similar anti-HBV activity as the lettuce extracts in vitro. The inhibition rate on HBsAg was up to 77.4%. Moreover, both the lettuce extracts and luteolin-7-O-glucoside functioned as organic antioxidants and, significantly attenuated HBV-induced intracellular reactive oxygen species (ROS accumulation. Luteolin-7-O-glucoside also normalized ROS-induced mitochondrial membrane potential damage, which suggests luteolin-7-O-glucoside inhibits HBsAg and HBV replication via a mechanism involving the mitochondria. Our findings suggest luteolin-7-O-glucoside may have potential value for clinical application in CHB and may enhance HBsAg and HBV clearance when used as a combination therapy.

  8. Establishing exemption and clearance criteria by the regulatory authority

    International Nuclear Information System (INIS)

    Salih, A.E.A.

    2012-04-01

    This Project work discusses the relationship between the concepts of exemption and clearance, and their practical use in the overall scheme of regulatory control of practices. It also discusses how exemptions and clearance is established and the scope of its applications for regulatory control. The concept of general clearance levels for any type of material and any possible pathway of disposal is also introduced in this work. Guidance of the Group of Experts establishing scenarios for general clearance, parameter values, and a nuclide-specific list of calculated clearance levels is also presented. Regulatory authorities are required to develop guidance on exemption and clearance levels to assist licensees and registrants to know which practices and sources within practices are exempted from regulatory control and those to be cleared from further controls. Exemption and clearance levels are tools for assisting the Regulatory Authority to optimize the use of resources. (author)

  9. 14 CFR 1260.63 - Customs clearance and visas.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  10. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...

  11. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  12. Clearance Laboratory - Capability and measurement sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-08-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  13. Clearance Laboratory - Capability and measurement sensitivity

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-09-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  14. Lithium clearance in chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Holstein-Rathlou, N H; Leyssac, P P

    1989-01-01

    1. Lithium clearance measurements were made in 72 patients with chronic nephropathy of different aetiology and moderate to severely reduced renal function. 2. Lithium clearance was strictly correlated with glomerular filtration rate, and there was no suggestion of distal tubular reabsorption...... of lithium or influence of osmotic diuresis. 3. Fractional reabsorption of lithium was reduced in most patients with glomerular filtration rates below 25 ml/min. 4. Calculated fractional distal reabsorption of sodium was reduced in most patients with glomerular filtration rates below 50 ml/min. 5. Lithium...... that lithium clearance may be a measure of the delivery of sodium and water from the renal proximal tubule. With this assumption it was found that adjustment of the sodium excretion in chronic nephropathy initially takes place in the distal parts of the nephron (loop of Henle, distal tubule and collecting duct...

  15. Experience and lessons learnt from clearance in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, Stefan

    2002-01-01

    Clearance is an important corner-stone of waste management in nuclear installations in Germany. It has been practised successfully for around two decades. The importance of clearance can also be judged from the fact that it has been included detailedly in the new German Radiation Protection Ordinance. Currently, there are 19 NPPs and a number of fuel cycle installations in operation in Germany. The main waste quantities, however, arise from the dismantling of NPPs and fuel cycle installations which are currently in decommissioning. As most of the decommissioning projects are targeted for early dismantling instead of safe enclosure, there is already considerable experience with the application of clearance procedures and verification of clearance levels. The German waste management strategy is governed by two options: Clearance of the material (after decontamination and release measurement). After clearance, the material is no longer regarded as radioactive in a legal sense. Final disposal of the material as radioactive waste in a deep geological repository (no near-surface disposal facilities exist or are planned in Germany). A deep geological repository is planned to be operable around 2030. Stefan Thierfeldt described German clearance requirements and lessons learned from their application to decommissioning of power reactors. The great majority of the waste was in fact recycled, although the costs were dominated by the small fraction that had to be disposed of as radioactive waste. Among the lessons learned from the German experience were some revealing insights into the public perception of both clearance and of recycling of material from decommissioning of a nuclear installation

  16. 19 CFR 122.26 - Entry and clearance.

    Science.gov (United States)

    2010-04-01

    ... AIR COMMERCE REGULATIONS Private Aircraft § 122.26 Entry and clearance. Private aircraft, as defined... information as set forth in § 122.22(c), and grants electronic clearance via electronic mail or telephone...

  17. Comparison of renal clearance of 99mTc-DTPA and inulin, 131I-hippurate and PAH as well as of the creatinine clearance in Wistar rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Order of magnitude and standard deviation of 99m Tc-DTPA and 131 I-hippurate slope clearance were analyzed successively in 56 male Wistar rats. The clearance of 99m Tc-DTPA was 17.4 ± 3.43 μl · s -1 (100 g b-w) -1 , of 131 I-hippurate 34.3 ± 7.21 μl · s -1 (100 g b-w) -1 . In 17 rats inulin and PAH clearances were analyzed by steady state method with permanent infusion and 3 to 4 urine collection periods 3 days later. The endogeneous creatinine clearance was determined within the same periods. The 99m Tc-DTPA slope clearance corresponded to the inulin clearance, as well as the hippurate clearance to the PAH clearance. The high filtration fraction calculated from nuclear medicine and chemical clearance methods and the low PAH extraction (42%) let suggest that PAH and hippurate are eliminated only incompletely from plasma in rat kidney and are unsuitable for determination of renal blood supply in rats. The creatinine clearance with 4.7 ± 1.38 μl · s -1 (100 g b-w) -1 was far beneath the clearance of inulin and 99m Tc-DTPA, supposing that creatinine is reabsorbed tubularly in part and the creatinine clearance can not be used for valuation of the GFR in rats. However, for this the 99m Tc-DTPA clearance in Wistar rats seems to be well suited. (author)

  18. Clearance systems in the brain—implications for Alzheimer disease

    Science.gov (United States)

    Tarasoff-Conway, Jenna M.; Carare, Roxana O.; Osorio, Ricardo S.; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V.; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J.

    2015-01-01

    Accumulation of toxic protein aggregates—amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles—is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood–brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ. PMID:26195256

  19. Clearance systems in the brain-implications for Alzheimer disease.

    Science.gov (United States)

    Tarasoff-Conway, Jenna M; Carare, Roxana O; Osorio, Ricardo S; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J

    2015-08-01

    Accumulation of toxic protein aggregates-amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles-is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood-brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ.

  20. Secretin enhances [14C]erythritol clearance in unanesthetized dogs

    International Nuclear Information System (INIS)

    Lewis, M.H.; Baker, A.L.; Dhorajiwala, J.; Moossa, A.R.

    1982-01-01

    To determine the effect of secretin infusion on clearance of inert markers into bile, unanesthetized dogs fitted with Thomas cannulas received continuous infusions of [ 14 C]erythritol and [ 3 H]inulin throughout study. Taurocholic acid administered sequentially at 9.0, 20.0, and 40.0 mumol/min enhanced [ 14 C]erythritol clearance, and GIH secretin (3 units/min) administered along with TCA (40.0 mumol/min) increased [ 14 C]erythritol clearance from 4.9 +/- 1.2 ml/10 min to 6.8 +/- 1.3 ml/10 min (P less than 0.001), but simultaneously measured [ 3 H]inulin clearance was unaltered. Secretin alone also increased [ 14 C]erythritol clearance but did not alter [ 3 H]inulin clearance. The increase in [ 14 C]erythritol clearance per unit increase in bile flow was less during secretin infusion than TCA. Thus, secretin increases [ 14 C]erythritol transport through restricted channels, probably distal to the canaliculi. [ 14 C]Erythritol may not be an accurate marker for canalicular bile flow in dogs during secretin infusion

  1. Comparison of renal clearance of 99mTc-DTPA and inulin 131I-hippurate and PAH as well as creatinine clearance in Wistar-rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Averages and standard deviations of 99m Tc-DTPA and 131 I-hippurate slope clearance were consecutively determined for 56 male Wistar rats, with a body-weight of 271 ± 69 g in a single investigation. Clearance of 99m Tc-DTPA was 17.4 ± 3.4, that of 131 I-hippurate was 34.3 ± 7.2 μl · s -1 per 100 g body weight. For 17 rats inulin and PAH clearances were determined after 3 days with the steady-state method with continuous infusion and 3-4 periods of urine collection. During the same periods endogeneous creatinine clearance was determined. 99m Tc-DTPA slope clearance correlated well with inulin clearance, also the hippurate with the PAH clearance. The high values of the filtration fraction, calculated from radioisotope and chemical methods, and the low PAH extraction of 42% lead to the conclusion, that PAH and hippurate are incompletely eliminated by the rat kidney from plasma and therefore are inadequate for determining renal blood flow in rats. Creatinine clearance was 4.7 ± 1.38 μl · s -1 per 100 g body weight, much lower than that of inulin and 99m Tc-DTPA. Therefore is assumed, that tubular reabsorption of creatinine occurs and creatinine clearance cannot serve for the evaluation of GFR in rats. For this, however, the clearance of 99m Tc-DTPA seems well applicable in Wistar rats. (author)

  2. Development of a digital droplet PCR assay to measure HBV DNA in patients receiving long-term TDF treatment.

    Science.gov (United States)

    Liu, Yang; Cathcart, Andrea L; Delaney, William E; Kitrinos, Kathryn M

    2017-11-01

    The COBAS TaqMan assay has a lower limit of quantification (LLOQ) of 169 HBV copies/mL and a lower limit of detection (LLOD) of 58 copies/mL. HBV DNA below the TaqMan LLOQ is classified as target not detected (TND) (HBV DNA to 8 copies/mL. HBV DNA levels in plasma from patients with or without HBsAg seroconversion were assessed by ddPCR. For patients who did not achieve HBsAg seroconversion, the majority of TD samples (33/58, 57%) were HBV DNA positive by ddPCR while (10/37, 27%) of TND samples were positive. In contrast, for patients who achieved HBsAg seroconversion, HBV DNA was rarely detected by ddPCR after HBsAg seroconversion (1/28, 3.6%). ddPCR is a sensitive method to evaluate low-level viral replication in plasma samples. Frequent detection of HBV DNA by ddPCR among patients who did not achieve HBsAg seroconversion suggests new agents may be needed to suppress low levels of replicating HBV. Copyright © 2017. Published by Elsevier B.V.

  3. Swing limb mechanics and minimum toe clearance in people with knee osteoarthritis.

    Science.gov (United States)

    Levinger, Pazit; Lai, Daniel T H; Menz, Hylton B; Morrow, Adam D; Feller, Julian A; Bartlett, John R; Bergman, Neil R; Begg, Rezaul

    2012-02-01

    Knee osteoarthritis (OA) has been shown to be a risk factor for falls. Reductions in foot clearance during the swing phase of walking can cause a trip and potentially lead to a fall. This study examined the swing phase mechanics of people with and without knee OA during walking. Minimum toe clearance (MTC) height, joint angles at the time of MTC and the influence of the angular changes of the hip, knee and ankle of the swing leg on foot clearance using sensitivity analysis were investigated in 50 knee OA participants and 28 age-matched asymptomatic controls. Although both groups had a similar MTC height (controls: 12.8±6.7 mm, knee OA: 13.4±7.0 mm), the knee OA group used a different strategy to achieve the same foot clearance, as evidenced by greater knee flexion (52.5±5.3° vs 49.4±4.8°, p=0.007), greater hip abduction (-3.6±3.3° vs -1.8±3.3°, p=0.03) and less ankle adduction (2.8±1.9° vs 4.2±2.1°, p=0.01). MTC height was comparable between the groups, however a different swing phase mechanism was used by the knee OA. Although adequate MTC is an important component of safe locomotion, it does not appear to be impaired in people with knee OA. Other factors, such as inadequate responses to postural perturbation, may be responsible for falls in this group. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Metabolic clearance rate and urinary clearance of purified beta-core

    International Nuclear Information System (INIS)

    Wehmann, R.E.; Blithe, D.L.; Flack, M.R.; Nisula, B.C.

    1989-01-01

    We injected a highly purified preparation of the beta-core molecule, a fragment of hCG beta excreted in pregnancy urine, into five men and three women to determine its kinetic parameters, MCR, and urinary clearance. The beta-core molecule was distributed in an initial volume [1950 +/- 156 (mean +/- SEM) mL/m2 body surface area] approximately equal to the estimated plasma volume. Its disappearance was multiexponential on a semilogarithmic plot, with a rapid phase t1/2 of 3.5 +/- 0.7 min and a slow phase t1/2 of 22.4 +/- 4.2 min. The transit time (the mean time spent by a molecule of beta-core in transit) was 20.6 +/- 2.1 min. The MCR was 192.0 +/- 8.0 mL/min.m2 body surface area. About 5% of the injected dose of beta-core was excreted into the urine in the first 30 min after injection, and low levels of excretion persisted for up to 7 days. The urinary clearance rate of beta-core was 13.7 +/- 1.4 mL/min.m2, accounting for about 8% of the elimination of beta-core from the plasma. The beta-core immunoreactivity in serum and urine was characterized by gel filtration and three independent RIA systems to show that its properties were indistinguishable from those of the injected beta-core. Serum levels of beta-core in pregnant women were less than 0.2 ng/mL, while the amounts excreted in their urine were as much as 5 mg/day. Based on these clearance parameters of beta-core in normal subjects, less than 0.2% of the beta-core excreted in pregnancy urine is derived by urinary clearance of plasma beta-core. Therefore, more than 99% of the beta-core excreted in pregnancy urine is derived from beta-core in a compartment separate from plasma. In particular, these data indicate that there is relatively little placental secretion of beta-core into plasma and that placental secretion does not account for the vast majority of beta-core in pregnancy urine

  5. Allometric scaling for predicting human clearance of bisphenol A

    International Nuclear Information System (INIS)

    Collet, Séverine H.; Picard-Hagen, Nicole; Lacroix, Marlène Z.; Puel, Sylvie; Viguié, Catherine; Bousquet-Melou, Alain; Toutain, Pierre-Louis; Gayrard, Véronique

    2015-01-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min

  6. Allometric scaling for predicting human clearance of bisphenol A

    Energy Technology Data Exchange (ETDEWEB)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr; Puel, Sylvie, E-mail: s.puel@envt.fr; Viguié, Catherine, E-mail: c.viguie@envt.fr; Bousquet-Melou, Alain, E-mail: a.bousquet-Melou@envt.fr; Toutain, Pierre-Louis, E-mail: pltoutain@wanadoo.fr; Gayrard, Véronique, E-mail: v.gayrard@envt.fr

    2015-05-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.

  7. 48 CFR 2452.237-75 - Clearance of contractor personnel.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Clearance of contractor... Clauses 2452.237-75 Clearance of contractor personnel. As prescribed in 2437.110(e), insert the following clause in solicitations and contracts. Clearance of Contractor Personnel (OCT 1999) (a) General. This...

  8. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations

    International Nuclear Information System (INIS)

    Lindblad, H.G.; Berg, U.B.

    1994-01-01

    The authors have evaluated iohexol as a filtration marker in 150 children. The clearance of iohexol was compared with that of inulin or with a formula clearance. The single-sample clearance of iohexol showed a good correlation with the clearance of inulin. The clearance of iohexol correlated well with the formula clearance. The optimal blood sampling time for iohexol clearance determinations appears to be between 120 and 180 min after injection, at least in patient with relatively normal filtration rates. It is concluded that iohexol clearance is an accurate method of determining the glomerular filtration rate in clinical practice. 25 refs., 5 figs

  9. High rates of chronic HBV genotype E infection in a group of migrants in Italy from West Africa: Virological characteristics associated with poor immune clearance.

    Science.gov (United States)

    Malagnino, Vincenzo; Salpini, Romina; Maffongelli, Gaetano; Battisti, Arianna; Fabeni, Lavinia; Piermatteo, Lorenzo; Colagrossi, Luna; Fini, Vanessa; Ricciardi, Alessandra; Sarrecchia, Cesare; Perno, Carlo Federico; Andreoni, Massimo; Svicher, Valentina; Sarmati, Loredana

    2018-01-01

    Hepatitis B virus (HBV) genotype E almost exclusively occurs in African people, and its presence is more commonly associated with the development of chronic HBV (CHB) infection. Moreover, an epidemiological link has been found between the distribution of HBV genotype E infection and African countries with high incidences of hepatocellular carcinoma. As part of a programme for the health assessment of migrants, we evaluated 358 young African subjects for HBV infection; 58.1% (208/358) were positive for an HBV marker, and 54 (25.5%) had CHB. Eighty-one percent of the CHB subjects were infected with HBV genotype E, with a median serum HBV-DNA of 3.2 (IQR: 2.7-3.6) logIU/ml. All patients had high serum HBsAg titres (10,899 [range 5,359-20,272] IU/ml), and no correlation was found between HBsAg titres and HBV-DNA plasma levels. RT sequence analysis showed the presence of a number of immune escape mutations: strains from all of the patients had a serine at HBsAg position 140; 3 also had T116N, Y100C, and P142L+S143L substitutions; and 1 had a G112R substitution. Six (18%) patients had stop-codons at position 216. In 5 of the 9 (26.5%) CHB patients, ultrasound liver biopsy, quantification of total intrahepatic HBV-DNA and cccDNA, and RT/HBsAg sequencing were performed. The median (IQR) total intrahepatic HBV-DNA was 766 (753-1139) copies/1000 cells, and the median (IQR) cccDNA was 17 (10-27) copies/1000 cells. Correlations were observed for both total intrahepatic HBV-DNA and cccDNA with serum HBV-DNA, while no correlation was found for the HBsAg titres. A difference of 2.5/1,000 nucleotides was found in the HBsAg sequences obtained from plasma and from liver tissue, with 3 cases of possible viral anatomical compartmentalization. In conclusion, a high rate of CHB infection due to the E genotype was demonstrated in a group of immigrants from Western Africa. An analysis of the viral strains obtained showed the virological characteristics of immune escape, which may be the

  10. Security Clearance Tracking System

    Data.gov (United States)

    National Archives and Records Administration — SCTS supports the adjudication process of private background investigations and clearances for potential employees, contractors, interns and student workers.

  11. Centrifugal compressor tip clearance and impeller flow

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari [Laboratory of Fluid Dynamics, LUT School of Energy Systems, Lappeenranta University of Technology, Lappeenranta (Finland); Engeda, Abraham [Turbomachinery Laboratory, Dept. of Mechanical Engineering, Michigan State University, East Lansing (United States)

    2016-11-15

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease.

  12. Centrifugal compressor tip clearance and impeller flow

    International Nuclear Information System (INIS)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari; Engeda, Abraham

    2016-01-01

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease

  13. Hepatic drug clearance following traumatic injury.

    Science.gov (United States)

    Slaughter, R L; Hassett, J M

    1985-11-01

    Trauma is a complex disease state associated with physiologic changes that have the potential to alter hepatic drug clearance mechanisms. These responses include alterations in hepatic blood flow, reduction in hepatic microsomal activity, reduction in hepatic excretion processes, and changes in protein binding. Hepatic blood flow is influenced by sympathomimetic activity. Both animal and human studies demonstrate an initial reduction and subsequent increase in hepatic blood flow, which coincides with an observed increase and subsequent return to normal in serum catecholamine concentrations. Unfortunately, there are no human studies that address the importance these findings may have to the clearance processes of high intrinsic clearance compounds. Animal studies of trauma indicate that hepatic microsomal activity is depressed during the post-traumatic period. Reduction in the hepatic clearance of antipyrine, a model low intrinsic compound, has also been demonstrated in animal models of trauma. In addition to these effects, hepatic excretion of substances such as indocyanine green and bilirubin have been demonstrated to be impaired in both traumatized animals and humans. Finally, substantial increases in the serum concentration of the binding protein alpha 1-acid glycoprotein occur in trauma patients. This has been reported to be associated with subsequent decreases in the free fraction of lidocaine and quinidine. In addition to changing serum drug concentration/response relationships, the pharmacokinetic behavior of drugs bound to alpha 1-acid glycoprotein should also change. Preliminary observations in our laboratory in a dog model of surgically-induced trauma have shown a reduction in the total clearance of lidocaine and reduction in free lidocaine concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Diminished creatinine clearance in anorexia nervosa: reversal with weight gain.

    OpenAIRE

    Boag, F; Weerakoon, J; Ginsburg, J; Havard, C W; Dandona, P

    1985-01-01

    To assess whether patients with anorexia nervosa have abnormalities in creatinine clearance, we measured plasma creatinine concentration, urinary creatinine excretion, and creatinine clearance in 10 patients with anorexia nervosa before and during treatment. Urinary creatinine excretion and creatinine clearance were diminished in all patients. Nine patients had significant decreases in their plasma creatinine and creatinine clearance was increased even when corrected for body weight and body ...

  15. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    Science.gov (United States)

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  16. Analysis of conservativity analysis for clearance levels. Final report

    International Nuclear Information System (INIS)

    Deckert, A.; Thierfeldt, S.

    1997-07-01

    When deriving clearance levels for material from nuclear installations it is necessary to proceed with a certain degree of conservativity. This can, however, differ between various sets of clearance levels leading to inconsistencies between clearance pathways. The aim of the work therefore is to compare levels of conservativity for the following two sets of clearance levels: clearance levels for disposal as conventional waste and for metallic materials for recycling/reuse. A method was developed to quantify the degree of conservativity and make it comparable. The actual and future situation for disposal of (conventional) wastes in Germany was analysed. In addition, the masses, nuclide vectors, geographical distribution etc. for slightly radioactive material being cleared for conventional disposal was analysed and modelled and the resulting dose distributions were calculated. The values for the clearance levels were taken from the 1995 recommendation by the German Commission on Radiation Protection (SSK). By using realistic scenarios, the exposure was calculated for the personnel on the landfills and for persons of the general public being exposed via groundwater pathways. It could be shown that the trivial dose range will not be exceeded even if the masses of cleared material per landfill site exceed 100 Mg/a. Because of the types and distribution of nuclear installations in Germany and because of the nuclide vectors it is therefore not necessary to limit the masses per landfill sites. Clearance levels that are determined by the exposure pathways external exposure to and the inhalation of dust by the landfill personnel show a similar level of conservativity as those for metal scrap. This means that the clearance levels for gamma emitting nuclides are not overly restrictive. Although radiologically justified, raising the clearance levels would not lead to an increase of the material quantities because other nuclides of the respective nuclide vectors are limiting. In

  17. Comparison of myocardial 201Tl clearance after maximal and submaximal exercise: implications for diagnosis of coronary disease: concise communication

    International Nuclear Information System (INIS)

    Massie, B.M.; Wisneski, J.; Kramer, B.; Hollenberg, M.; Gertz, E.; Stern, D.

    1982-01-01

    Recently the quantitation of regional 201 Tl clearance has been shown to increase the sensitivity of the scintigraphic detection of coronary disease. Although 201 Tl clearance rates might be expected to vary with the degree of exercise, this relationship has not been explored. We therefore evaluated the rate of decrease in myocardial 201 Tl activity following maximal and submaximal stress in seven normal subjects and 21 patients with chest pain, using the seven-pinhole tomographic reconstruction technique. In normals, the mean 201 Tl clearance rate declined from 41% +/- 7 over a 3-hr period with maximal exercise to 25% +/- 5 after 3 hr at a submaximal level (p less than 0.001). Similar differences in clearance rates were found in the normally perfused regions of the left ventricle in patients with chest pain, depending on whether or not a maximal end point (defined as either the appearance of ischemia or reaching 85% of age-predicted heart rate) was achieved. In five patients who did not reach these end points, 3-hr clearance rates in uninvolved regions averaged 25% +/- 2, in contrast to a mean of 38% +/- 5 for such regions in 15 patients who exercised to ischemia or an adequate heart rate. These findings indicate that clearance criteria derived from normals can be applied to patients who are stressed maximally, even if the duration of exercise is limited, but that caution must be used in interpreting clearance rates in those who do not exercise to an accepted end point

  18. Numerical investigation of hub clearance flow in a Kaplan turbine

    Science.gov (United States)

    Wu, H.; Feng, J. J.; Wu, G. K.; Luo, X. Q.

    2012-11-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  19. Numerical investigation of hub clearance flow in a Kaplan turbine

    International Nuclear Information System (INIS)

    Wu, H; Feng, J J; Wu, G K; Luo, X Q

    2012-01-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  20. Determination of renal clearance of 131I-hippuran

    International Nuclear Information System (INIS)

    Ridzon, S.

    1982-01-01

    The author presents his own method for the determination of total renal clearance of 131 I-hippuran under conditions of its diminishing plasma concentration following single intravenous administration. Total renal clearance is determined as the ratio of the amount of activity excreted into the urine over a certain time interval and of the area limited by the curve of activity decrease in plasma and by the time axis in the corresponding interval. The results are demonstrated in five investigated healthy subjects, and very good agreement of the calculated values of total renal clearance for different time intervals in the same subject is pointed out. When isotope nephrography is simultaneously performed, the method allows to determine also the values of isolated renal clearance for each kidney separately. (author)

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Research Consortia CF Biomarker Consortium CFTR 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ...

  2. Inherited Disorders of Bilirubin Clearance

    Science.gov (United States)

    Memon, Naureen; Weinberger, Barry I; Hegyi, Thomas; Aleksunes, Lauren M

    2016-01-01

    Inherited disorders of hyperbilirubinemia may be caused by increased bilirubin production or decreased bilirubin clearance. Reduced hepatic bilirubin clearance can be due to defective 1) unconjugated bilirubin uptake and intrahepatic storage, 2) conjugation of glucuronic acid to bilirubin (e.g. Gilbert syndrome, Crigler-Najjar syndrome, Lucey-Driscoll syndrome, breast milk jaundice), 3) bilirubin excretion into bile (Dubin-Johnson syndrome), or 4) conjugated bilirubin re-uptake (Rotor syndrome). In this review, the molecular mechanisms and clinical manifestations of these conditions are described, as well as current approaches to diagnosis and therapy. PMID:26595536

  3. Approaches towards establishing of clearance levels in Japan

    International Nuclear Information System (INIS)

    Sumitani, N.; Watanabe, I.; Okoshi, M.

    1998-01-01

    It is important to establish necessary regulatory systems for decommissioning waste management, especially to establish clearance levels from regulatory control. To establish the regulatory systems, the Nuclear Safety Commission (NSC) has been discussing the unconditional clearance levels for materials from nuclear reactors since May 1997. The NSC tries to derive unconditional clearance levels for the materials such as concrete and ferrous metal, arising from nuclear reactor decommissioning. In the derivation, both disposal and recycle/reuse of the materials are considered. Typical scenarios and parameter values for dose estimation are selected considering the Japanese natural and social conditions. Preliminary clearance levels were derived from 10 μSv/yr of individual dose criterion and deterministic analysis. For most radionuclides, the preliminary results are the same order of magnitude recommended in IAEA-TECDOC-855. Some radionuclides such as β emitters, however, are different order of magnitude from those recommended in IAEA-TECDOC-855. It is necessary that international organizations lead the discussions on the clearance levels to conclude final consensus. (author)

  4. Green technology; only Forest Clearance is needed

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was land in Murmurwadi still under litigation made available? How was ...

  5. Nuclear regulation. NRC's security clearance program can be strengthened

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Kruslicky, Mary Ann; Bagnulo, John E.

    1988-12-01

    Because of the national security implications of its programs, the Nuclear Regulatory Commission (NRC) investigates the background of its employees and consultants as well as others to ensure that they are reliable and trustworthy. If the investigation indicates that an employee will not endanger national security, NRC grants a security clearance that allows access to classified information, material, and facilities. NRC also requires periodic checks for some clearance holders to ensure their continued clearance eligibility. The Chairman, Subcommittee on Environment, Energy, and Natural Resources, House Committee on Government Operations, asked GAO to review NRC's personnel security clearance program and assess the procedures that NRC uses to ensure that those who operate nuclear power plants do not pose a threat to the public. The Atomic Energy Act of 1954 requires NRC to conduct background investigations of its employees and consultants as well as others who have access to classified information, material, or facilities. To do this, NRC established a personnel security clearance program. Under NRC policies, a security clearance is granted after the Office of Personnel Management (OPM) or the Federal Bureau of Investigation checks the background of those applying for an NRC clearance. NRC also periodically reassesses the integrity of those holding the highest level clearance. NRC employees, consultants, contractors, and licensees as well as other federal employees hold approximately 10,600 NRC clearances. NRC does not grant clearances to commercial nuclear utility employees unless they require access to classified information or special nuclear material. However, the utilities have voluntarily established screening programs to ensure that their employees do not pose a threat to nuclear plants. NRC faces a dilemma when it hires new employees. Although its policy calls for new hires to be cleared before they start work, the security clearance process takes so long

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study Services Working With the TDN Tools and Resources ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center ...

  8. A study for promoting measures of social acceptance on clearance system

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Torii, Hiroyuki; Fujii, Yasuhiko

    2007-01-01

    Clearance is one of the useful concepts to manage large amounts of slightly contaminated solid radioactive materials generated from the decommissioning of nuclear facilities. Cleared materials are expected to be disposed of as conventional wastes or recycled to produce consumer goods. In Japan, the legal frame-work for clearance was established in 2005 by amending the Law to regulate nuclear materials, reactors and so on. However, it is not so clear whether the general public understands clearance well. In this paper, major concerns about clearance from the general public are analyzed based on the public comments for reports on clearance prepared by the Nuclear Safety Commission and the Nuclear Institute Safety Agency. The major anxieties for clearance expressed by the general public are the safety of clearance, unknown factors of radiation effects, possibilities of excess radiation exposure due to inadequate measurements of radioactivities and fairness in decision making. In order to deal with those anxieties, some countermeasures including the confidence in nuclear operators and regulatory authorities and controllability of clearance by the general public are discussed to promote the social acceptance of clearance by the general public. (author)

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study ...

  10. Recent advances in understanding and diagnosing hepatitis B virus infection [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Slim Fourati

    2016-09-01

    Full Text Available Hepatitis B virus (HBV infects approximately 240 million individuals worldwide. Recent advances in the virology, immunopathogenesis, and diagnosis of HBV infection are summarized in this review article. The identification of a hepatocyte-specific cellular receptor for HBV, the sodium taurocholate co-transporting polypeptide (NTCP, made it possible to develop reliable cell culture systems and better understand the early steps of the viral lifecycle. Viral and host factors involved in covalently closed circular DNA synthesis, stability, and transcriptional regulation have also been identified and provide potential targets for new drugs. Based on recent evidence showing trained immunity in immune-tolerant patients, the immune tolerance and immune clearance phases have been renamed the non-inflammatory and inflammatory phases, respectively. New diagnostic and monitoring tools are now available, including rapid diagnostic tests for hepatitis B surface antigen (HBsAg detection, HBsAg quantification assays, anti-HBc antibody quantification assays, an HBV core-related antigen (HBcrAg quantification test, new HBV DNA detection and quantification assays, and an HBV RNA quantification test. Their clinical utility is under study. Finally, new antiviral and immune modulation approaches are in the preclinical or early clinical developmental stages, with the goal to achieve functional cure or ideally (if possible eradication of HBV infection.

  11. Intraarticular volume and clearance in human synovial effusions

    International Nuclear Information System (INIS)

    Wallis, W.J.; Simkin, P.A.; Nelp, W.B.; Foster, D.M.

    1985-01-01

    Intraarticular volumes were measured by radiolabeled albumin (RISA) distribution in chronic knee effusions from 11 rheumatoid arthritis patients and 9 osteoarthritis patients. Volumes of synovial fluid obtained at joint aspiration were substantially less than those found by RISA dilution. Up to 24 hours was needed for full distribution of RISA throughout the intraarticular compartment. Measured 123I and RISA radioactivity over the knee described monoexponential rate constants, lambda (minute-1). The clearance of 123I and RISA from synovial effusions was derived by the formulation volume (ml) X lambda (minute-1) = clearance (ml/minute). RISA clearance in rheumatoid effusions was significantly greater than that found in osteoarthritis effusions. Intraarticular volume and isotope clearance were easily quantified and provide measures for further evaluating the microvascular physiology of synovial effusions

  12. Carbamazepine and carbamazepine-10,11-epoxide clearance measurements during continuous venovenous hemofiltration in a massive overdose.

    Science.gov (United States)

    Smollin, Craig Geoffrey; Petrie, Matthew S; Kearney, Thomas

    2016-06-01

    Carbamazepine (CBZ) overdose can result in significant neurologic and cardiovascular toxicity, and is compounded by the presence of an active metabolite, carbamazepine-10,11-epoxide (CBZE). Existing publications describing continuous venovenous hemofiltration (CVVH) in CBZ overdose are limited in their ability to calculate accurate clearances. We report a case of CBZ overdose treated with CVVH with detailed measurement of CBZ, CBZE and their respective clearances calculated utilizing serial effluent measurements. This was coupled with serum level determinations comparing two analytical methodologies, time-of-flight mass spectroscopy and an immunoassay. A 41-year-old woman presented unresponsive after an overdose of CBZ. Initial CBZ serum levels were markedly elevated (57.8 μg/mL) and continued to rise. Due to continued hemodynamic instability, extracorporeal removal was initiated using CVVH. During the first 30 h of CVVH, interval serum samples and all ultrafiltrate bags were collected and analyzed. Serum and effluent levels of CBZ and CBZE were measured using an Agilent 6230 time-of-flight high-resolution mass spectrometer (TOF-MS). CBZ levels were also obtained utilizing the Microgenics CEDIA Carbamazepine Immunoassay (Thermo Fisher, Waltham, MA) for serum and effluent samples. Immunoassay analysis was performed using Siemens ADVIA 1800 instrument. The clearances achieved for CBZE (mean = 25.2, range 17.7-42.6 mL/min) exceeded that for CBZ (mean = 18.1, range 12.7-28.7 mL/min). CVVH removed a total of 1293 and 1261 mg of CBZ and CBZE, respectively. Serum levels of CBZ measured by immunoassay when compared with TOF-MS indicated cross reactivity of CBZE with the immunoassay. CVVH removed CBZE with higher clearances than CBZ. However, CVVH clearance rates for both CBZ and CBZE were lower than published clearances of CBZ and CBZE by intermittent hemodialysis. Our methodology allowed for a precise pharmacokinetic assessment of clearance based on

  13. Evaluation of a semi-automatic radioimmunoassay for hepatitis B surface antigen (HBsAg)

    International Nuclear Information System (INIS)

    Vries, J. de; Kruining, J.; Heijtink, R.A.

    1983-01-01

    The recently developed semi-automatic Hepatube system was evaluated in comparison to another radioimmunoassay for the detection of hepatitis B surface antigen (HBsAg), the manual Ausria II-125 test. After incubation of serum in anti-HBs coated tubes, the Hepatube system uses a machine to wash the tubes and to add tracer. After a second incubation, tubes are washed again in the machine and are manually transferred to the #betta# counter. Two machines were used. Machine 1 had an undefined defect. Of 1490 samples tested, 69 (4.6%) gave false-positive results versus 11 (0.7%) in the Ausria II-125 test. Machine 2 had one false-positive result among 920 samples versus 5 in the Ausria II-125 test. The sensitivity was measured with reference panels from Wellcome and Abbott as well as in titration series. The Hepatube system was found to be a factor three less sensitive than the Ausria II-125 test. The Hepatube processor is easy to handle; radioactive material can be held at a distance during the whole procedure; waste material is limited and less voluminous than in the Ausria II-125 test. (Auth.)

  14. Axial compressor blade design for desensitization of aerodynamic performance and stability to tip clearance

    Science.gov (United States)

    Erler, Engin

    of the local blade passage. These flow features are isolated and validated based on the reference rotor design through changes in the inlet total pressure condition to alter incoming flow momentum and blade number count to change double leakage rate. In terms of flow mechanism, double leakage is shown to be detrimental to performance and stability, and its proportional increase with tip clearance size explains the sensitivity increase in the presence of double leakage and, conversely, the desensitization effect of reducing or eliminating double leakage. The increase in incoming meridional momentum in the tip region reduces sensitivity to tip clearance through its reduction of double leakage as well as through improved mixing with tip clearance flow, as demonstrated by an analytical model without double leakage flow. The above results imply that any blade design strategy that exploits the two desensitizing flow features would reduce the performance and stability sensitivity to tip clearance size. The increase of the incoming meridional momentum can be achieved through forward chordwise sweep of the blade. The reduction of double leakage without changing blade pitch can be obtained by decreasing the blade stagger angle in the tip region. Examples of blade designs associated with these strategies are shown through CFX simulations to be successful in reducing sensitivity to tip clearance size.

  15. The tear turnover and tear clearance tests - a review.

    Science.gov (United States)

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  17. Clearance of buildings for demolition: ways to clearance on the standing structure for covered surfaces and inaccessible areas

    International Nuclear Information System (INIS)

    Thraenert, S.; Riemann, T.

    2014-01-01

    In general terms, the TUV NORD Nuclear services encompass safety assessments, design reviews, documentation re-views and inspections. They reflect the full scope of a technical service provider in the nuclear field. In the domestic market, these services are provided for the regulator, whereas in the international market any party involved in a nuclear project is a potential customer of TUV NORD Nuclear. This implies that TUV NORD Nuclear is offering consultancy, engineering and inspection services. Regarding the clearance of buildings for demolition, there are two different possible ways for the radiological characterization. The first option is a characterization on the standing structure before demolition and the second option is the characterization of the building rubble after demolition. According to the German Radiation Protection Ordinance, buildings of decommissioned nuclear sites have to be preferentially cleared on the standing structure. If compliance with the surface specific clearance levels is achieved on the standing structure, usually the cleared buildings can be demolished and the resulting rubble may be used without any further radiological considerations. In the case of the former nuclear power plant Wuergassen the majority of the building rubble is scheduled to stay on site to serve as backfill for the building pit. As such a scenario was not considered in the radiological considerations of, e.g., the German Radiation Protection Ordinance, an additional dose calculation was carried out for Wuergassen NPP basing on its radiological characteristics to directly prove compliance with the de-minimis-concept. The radiation controlled area (RCA) of Wuergassen NPP comprises an area of about 140.000 m 2 . This area is more or less easily accessible to characterization and decontamination using, if necessary, scaffoldings or lifting platforms. Up to the beginning of 2013, compliance with the surface specific clearance levels was verified on the standing

  18. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.

    Science.gov (United States)

    Lizhang, Jia; Taylor, Simon D; Jin, Zhongmin; Fisher, John; Williams, Sophie

    2013-12-01

    Hemi-arthroplasty of the hip (an artificial femoral head articulating against the natural acetabulum) is used to treat fractured necks of femur; however, there is evidence that articulation causes erosion of the cartilage, resulting in pain for the patient. Parameters that may influence this cartilage erosion include head material and roughness, clearance between the head and acetabulum and activity levels of the patient. This study has assessed the effect of clearance of hemi-arthroplasty articulations on the contact stress, friction and cartilage deformation in an in vitro tribological simulation of the hemi-arthroplasty joint that applied dynamic loads and motion. It has been demonstrated that peak contact stress increased from 5.6 to 10.6 MPa as radial clearance increased from small (1.8 mm). In all samples, friction factor increased with time and was significantly less with extra-large clearances compared to small (<0.6 mm), medium (0.6-1.2 mm) and large (1.2-1.8 mm) clearances. The cartilage deformation observed was significantly greater in acetabulum samples paired to give small or extra-large clearances compared to those with medium or large clearances.

  19. Passing through the renal clearance barrier: toward ultrasmall sizes with stable ligands for potential clinical applications

    Directory of Open Access Journals (Sweden)

    Zhang XD

    2014-04-01

    Full Text Available Xiao-Dong Zhang,1 Jiang Yang,2 Sha-Sha Song,1 Wei Long,1 Jie Chen,1 Xiu Shen,1 Hao Wang,1 Yuan-Ming Sun,1 Pei-Xun Liu,1 Saijun Fan11Tianjin Key Laboratory of Molecular Nuclear Medicine, Institute of Radiation Medicine, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, People's Republic of China; 2Department of Biological Systems Engineering, University of Wisconsin-Madison, Madison, WI, USAAbstract: The use of nanoparticles holds promise for medical applications, such as X-ray imaging, photothermal therapy and radiotherapy. However, the in vivo toxicity of inorganic nanoparticles raises some concern regarding undesirable side effects which prevent their further medical application. Ultrasmall sub-5.5 nm particles can pass through the barrier for renal clearance, minimizing their toxicity. In this letter we address some recent interesting work regarding in vivo toxicity and renal clearance, and discuss the possible strategy of utilizing ultrasmall nanomaterials. We propose that small hydrodynamic sized nanoclusters can achieve both nontoxic and therapeutic clinical features.Keywords: in vivo clearance, gold nanoparticles, small size

  20. Axial compressor gas path design for desensitization of aerodynamic performance and stability to tip clearance

    Science.gov (United States)

    Cevik, Mert

    Tip clearance is the necessary small gap left between the moving rotor tip and stationary shroud of a turbomachine. In a compressor, the pressure driven flow through this gap, called tip clearance flow, has a major and generally detrimental impact on compressor performance (pressure ratio and efficiency) and aerodynamic stability (stall margin). The increase in tip clearance, either temporary during transient engine operations or permanent from wear, leads to a drop in compressor performance and aerodynamic stability which results in a fuel consumption increase and a reduced operating envelope for a gas turbine engine. While much research has looked into increasing compressor performance and stall margin at the design (minimum or nominal) tip clearance, very little attention has been paid for reducing the sensitivity of these parameters to tip clearance size increase. The development of technologies that address this issue will lead to aircraft engines whose performance and operating envelope are more robust to operational demands and wear. The current research is the second phase of a research programme to develop design strategies to reduce the sensitivity of axial compressor performance and aerodynamic stability to tip clearance. The first phase had focused on blade design strategies and had led to the discovery and explanation of two flow features that reduces tip sensitivity, namely increased incoming meridional momentum in the rotor tip region and reduction/elimination of double leakage. Double leakage is the flow that exits one tip clearance and enters the tip clearance of the adjacent blade instead of convecting downstream out of the rotor passage. This flow was shown to be very detrimental to compressor performance and stall margin. Two rotor design strategies involving sweep and tip stagger reduction were proposed and shown by CFD simulations to exploit these features to reduce sensitivity. As the second phase, the objectives of the current research

  1. Modified Augmented Renal Clearance Score Predicts Rapid Piperacillin and Tazobactam Clearance in Critically Ill Surgery and Trauma Patients

    Science.gov (United States)

    2014-04-24

    collision; VAP , ventilator-associated pneumonia. TABLE 2. PK Parameter Estimates for Free Piperacillin and Tazobactam in Patients Stratified by ARC Score...SOFA score are typically generated during routine care of the most severely ill patients . Positive screening test results (high ARC scores) can be...Modified Augmented Renal Clearance score predicts rapid piperacillin and tazobactam clearance in critically ill surgery and trauma patients Kevin S

  2. Maximizing in vivo target clearance by design of pH-dependent target binding antibodies with altered affinity to FcRn.

    Science.gov (United States)

    Yang, Danlin; Giragossian, Craig; Castellano, Steven; Lasaro, Marcio; Xiao, Haiguang; Saraf, Himanshu; Hess Kenny, Cynthia; Rybina, Irina; Huang, Zhong-Fu; Ahlberg, Jennifer; Bigwarfe, Tammy; Myzithras, Maria; Waltz, Erica; Roberts, Simon; Kroe-Barrett, Rachel; Singh, Sanjaya

    2017-10-01

    Antibodies with pH-dependent binding to both target antigens and neonatal Fc receptor (FcRn) provide an alternative tool to conventional neutralizing antibodies, particularly for therapies where reduction in antigen level is challenging due to high target burden. However, the requirements for optimal binding kinetic framework and extent of pH dependence for these antibodies to maximize target clearance from circulation are not well understood. We have identified a series of naturally-occurring high affinity antibodies with pH-dependent target binding properties. By in vivo studies in cynomolgus monkeys, we show that pH-dependent binding to the target alone is not sufficient for effective target removal from circulation, but requires Fc mutations that increase antibody binding to FcRn. Affinity-enhanced pH-dependent FcRn binding that is double-digit nM at pH 7.4 and single-digit nM at pH 6 achieved maximal target reduction when combined with similar target binding affinities in reverse pH directions. Sustained target clearance below the baseline level was achieved 3 weeks after single-dose administration at 1.5 mg/kg. Using the experimentally derived mechanistic model, we demonstrate the essential kinetic interplay between target turnover and antibody pH-dependent binding during the FcRn recycling, and identify the key components for achieving maximal target clearance. These results bridge the demand for improved patient dosing convenience with the "know-how" of therapeutic modality by design.

  3. Stability, protein binding and clearance studies of [99mTc]DTPA. Evaluation of a commercially available dry-kit

    DEFF Research Database (Denmark)

    Rehling, M

    1988-01-01

    [99mTc]DTPA has achieved widespread use for the measurement of glomerular filtration rate (GFR) with the single injection plasma clearance technique and for gamma-camera renography. However, the quality of the commercial preparations varies. The purpose of the present investigation was to study...... the quality of a commercial [99mTc]DTPA preparation (C.I.S., France) with reference to stability, protein binding and accuracy of the determined plasma clearance values as a measure of GFR. The stability of the preparations was studied by thin-layer chromatography, the in vitro protein binding by Sephadex.......7% and 1.1%, respectively. The plasma clearance of [99mTc]DTPA was on an average 3.7% higher than that of [51Cr]EDTA in 27 patients. It is concluded that the [99mTc]DTPA preparation is reliable for the measurement of GFR. The preparation is stable for at least six hours at room temperature...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in CF Clinical Care Guidelines Cystic Fibrosis-Related Diabetes Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care Guidelines Chronic Medications to Maintain Lung ...

  5. 2015 Annual Report on Security Clearance Determinations

    Science.gov (United States)

    2016-06-28

    only have delegated investigative authority over their civilian employee population and therefore, can only report the overall timeliness for that...completed or pending security clearance determinations for government employees and contractors during the preceding fiscal year that have taken longer...Clearance Determinations to Congress. The IAA directs this report to include the number of United States Government (USG) employees who held a

  6. Dynamic modelling and experimental study of cantilever beam with clearance

    International Nuclear Information System (INIS)

    Li, B; Jin, W; Han, L; He, Z

    2012-01-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  7. Dynamic modelling and experimental study of cantilever beam with clearance

    Science.gov (United States)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... many challenges, including medical, social, and financial. By learning more about how you can manage your disease every day, you can ultimately help find a ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic ...

  9. Refrigeration system with clearance seals

    International Nuclear Information System (INIS)

    Holland, N. J.

    1985-01-01

    In a refrigeration system such as a split Stirling system, fluid seals associated with the reciprocating displacer are virtually dragless clearance seals. Movement of the displacer relative to the pressure variations in the working volume of gas is retarded by a discrete braking element. Because it is not necessary that the brake providing any sealing action, the brake can be designed for greater durability and less dependence on ambient and operating temperatures. Similarly, the clearance seal can be formed of elements having low thermal expansion such that the seal is not temperature dependent. In the primary embodiments the braking element is a split friction brake

  10. Chaos vibration of pinion and rack steering trapezoidal mechanism containing two clearances

    Science.gov (United States)

    Wei, Daogao; Wang, Yu; Jiang, Tong; Zheng, Sifa; Zhao, Wenjing; Pan, Zhijie

    2017-08-01

    The multi-clearances of breaking type steering trapezoidal mechanism joints influences vehicle steering stability. Hence, to ascertain the influence of clearance value on steering stability, this paper takes the steering mechanism of a certain vehicle type as a prototype that can be simplified into a planar six-bar linkage, then establishes the system dynamic differential equations after considering the two clearances of tie rods and the steering knuckle arms. The influence of the clearance parameters on the movement stability of the steering mechanism is studied using a numerical computation method. Results show that when the two clearances are equal, the planar movement of the tie rods changes from period-doubling to chaos as the clearances increase. When the two clearances are 0.25 mm and 1.5 mm respectively, the planar movements of the two side tie rods come into chaos, causing the steering stability to deteriorate. Moreover, with the increase of clearances, turning moment fluctuates more intensively and the peak value increases.

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... decisions about your health care. CF Genetics: The Basics CF Mutations Video Series Find Out More About ... of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing and ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway ... on their own. Share Facebook Twitter Email More options Print Share Facebook Twitter Email Print Permalink All ...

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in part to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of ... a cure for CF and supports a broad range of research initiatives to tackle the disease from ...

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care ... attack bacteria. Choose What's Best for You Your respiratory therapist or another member of your CF care ...

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  2. Measurement with nasal scintigraphy of nasal mucociliary clearance in normal man

    International Nuclear Information System (INIS)

    Murai, Sumiko

    1989-01-01

    Nasal mucociliary function was evaluated by nasal scintigraphy in normal subjects. A microdrop of HSA or saline labelled with 99m Tc was dripped into the middle part of each middle meatus in the nasal cavity and its clearance was observed by scinticamera. The accumulated concentration of RI was determined every 30 seconds for 10 minutes. The changes of accumulated concentration were studied, and a curve of decreasing RI-counts was obtained, with the 'clearance rate' defined as 100% for the count at the initial 30 seconds and 'half time' as the time when radioactivity was reduced to one half the initial count. Nasal resistance was measured by rhinomanometry with the oscillation method. In nonsmokers, 10μl of saline was cleared (78.0±10.4%) significantly faster than 10μl of HSA (59.9±24.6%), and there was no significant difference in the clearance between 10μl and 5μl of HSA (55.9±27.7%). In smakers, the mucociliary clearance of 10μl of HSA and saline was significantly lower than in nonsmokers. The clearance of 10μl of HSA reflects a pathological state much better than that of 5μl. In nonsmokers, there is a significant negative correlation between nasal resistance and clearance rate, suggesting that the more patent the nose, the faster the mucociliary clearance. When both nostrils were closed, the clearance rate was significantly depressed. When one nostril was closed, there was no significant effect on clearance. Nasal resistance was decreased by exercise with a bicycle ergometer. Nasal mucociliary clearance was slightly decreased after exercise but not significantly so. (J.P.N.)

  3. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Science.gov (United States)

    2013-12-20

    ... No. USCG-2013-0466] Overhead Clearance (Air-Draft) Accidents AGENCY: Coast Guard, DHS. ACTION... clearance (air-draft) accidents. In its petition, which calls for vessel masters to be provided with... accidents that it says were avoidable and that resulted in damage to or destruction of waterway...

  4. Manual hyperinflation in airway clearance in pediatric patients: a systematic review

    Science.gov (United States)

    de Godoy, Vanessa Cristina Waetge Pires; Zanetti, Nathalia Mendonça; Johnston, Cíntia

    2013-01-01

    Objective To perform an assessment of the available literature on manual hyperinflation as a respiratory physical therapy technique used in pediatric patients, with the main outcome of achieving airway clearance. Methods We reviewed articles included in the Lilacs (Latin American and Caribbean Literature on Health Sciences/Literatura Latino Americana e do Caribe em Ciências da Saúde), Cochrane Library, Medline (via Virtual Health Library and PubMed), SciELO (Scientific Electronic Library), and PEDro (Physiotherapy Evidence Database) databases from 2002 to 2013 using the following search terms: "physiotherapy (techniques)", "respiratory therapy", "intensive care", and "airway clearance". The selected studies were classified according to the level of evidence and grades of recommendation (method of the Oxford Centre for Evidence-Based Medicine) by two examiners, while a third examiner repeated the search and analysis and checked the classification of the articles. Results Three articles were included for analysis, comprising 250 children (aged 0 to 16 years). The main diagnoses were acute respiratory failure, recovery following heart congenital disease and upper abdominal surgery, bone marrow transplantation, asthma, tracheal reconstruction, brain injury, airway injury, and heterogeneous lung diseases. The studies were classified as having a level of evidence 2C and grade of recommendation C. Conclusions Manual hyperinflation appeared useful for airway clearance in the investigated population, although the evidence available in the literature remains insufficient. Therefore, controlled randomized studies are needed to establish the safety and efficacy of manual hyperinflation in pediatric patients. However, manual hyperinflation must be performed by trained physical therapists only. PMID:24213091

  5. The role of clearance in Germany - release of materials, buildings and sites

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    Clearance in Germany is far advanced. A complex regulatory framework exists in the Radiation Protection Ordinance (RPO/Strahlenschutzverordnung, StrlSchV) since 2001 which has replaced previous recommendations on clearance issued by the German Radiation Protection Commission (Strahlenschutzkommission, SSK). A number of options exist both for unconditional clearance (e.g. of all kinds of materials with no restrictions on the destination or future use) and for clearance for a specific purpose (e.g. recycling of metal scrap). For each clearance option there is a set of nuclide specific clearance levels which have been derived on the basis of the 10 Sv/a individual dose criterion using complex radiological models which are tailored to the respective material cycles (metal scrap, buildings, building rubble, waste for disposal, sites). The clearance levels have been thoroughly reviewed by the SSK. An extensive comparison to sets of clearance levels used in other countries or issued as guidance by international bodies revealed that the correspondence between values is between good and acceptable taking into account country-specific approaches and special assumptions which would not necessarily pertain to German situations. Clearance is a major factor in the material management, especially of nuclear installations undergoing decommissioning. The variety of clearance options leaves the operator of a nuclear installation sufficient flexibility for optimisation of the material management. Clearance is of particular importance in a country like Germany where the estimated costs for a future repository are very high and the interim storage facilities for radioactive material are limited and costly. While the licensee is responsible for his material management, the issuance of a clearance permit is done by the regulatory body upon application. The regulators may choose to use the clearance levels and regulations as stipulated by the RPO, or to impose site-specific regulations on

  6. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, A

    1984-01-01

    the clearance values based on arterial and venous sampling averaged 1.4 and 2.5 l/min, respectively (p less than 0.02). The difference in clearance values was due to peripheral uptake of NA averaging 45%. The plasma appearance rate on NA averaged 2.4 nmol/min before surgery and it increased to 9.5 nmol...... we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Make a Charitable Gift Our Corporate Supporters Workplace Engagement DONATE YOUR PROPERTY eCards for a Cure About ... airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... people with cystic fibrosis so that they make smart decisions about CF-related research, treatment, and access ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... CFTR Modulator Therapies Mucus Thinners Nebulizer Care at Home Vascular Access Devices PICCs and Ports Partnerships for ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  11. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    Science.gov (United States)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  12. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  13. Depressed reticuloendothelial clearance of platelets in rats after trauma.

    Science.gov (United States)

    Kaplan, J E; Moon, D G; Minnear, F L; Saba, T M

    1984-02-01

    Platelet microembolization may contribute to microcirculatory and organ damage following trauma and shock. It is hypothesized that posttraumatic reticuloendothelial depression predisposes to such microembolization by failure to clear altered platelets from the circulation. The present study evaluated the short-term (1 h) clearance and organ localization of radiolabeled homologous damaged platelets in normal rats and in rats following sublethal Noble-Collip drum trauma. Platelets were collected in citrated platelet-rich plasma from normal rats and labeled with 51Cr in citrated saline. Platelets were altered by repeated centrifugation in protein-free medium. These platelets differed functionally and morphologically from normal platelets. Disappearance of iv injected damaged platelets conformed to a two-compartment exponential clearance. Velocity of clearance in the rapid compartment correlated with hepatic platelet localization, whereas velocity of clearance in the second compartment correlated with splenic platelet localization. Clearance rate of the rapid compartment was depressed at 1 h after trauma and elevated at 24 h. These changes were associated with a decrease in hepatic platelet localization at 1 h and an increase above normal at 24 h. Splenic platelet localization was decreased by 3 h following trauma. Pulmonary platelet localization was increased at all times following trauma. It is concluded that the posttrauma state is associated with a defect in the reticuloendothelial system clearance of altered platelets, which may augment embolization of platelets in the lung.

  14. Intercalibration of mussel Mytilus edulis clearance rate measurements

    NARCIS (Netherlands)

    Kjerulf Petersen, J.; Bougrier, S.; Smaal, A.C.; Garen, P.; Robert, S.; Larsen, J.E.N.; Brummelhuis, E.B.M.

    2004-01-01

    Clearance rate (CR) was measured in blue mussels Mytilus edulis L. from Aiguillon Bay and the Oosterschelde using 3 different methods: the flow-through method, the bio-deposition method and the indirect or clearance method. CR differed significantly as a function of the method used and of the origin

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living longer and ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  16. DOD PERSONNEL CLEARANCES: Additional OMB Actions Are Needed to Improve the Security Clearance Process

    National Research Council Canada - National Science Library

    2006-01-01

    Our independent analysis of timeliness data showed that industry personnel contracted to work for the federal government waited more than one year on average to receive top secret clearances, longer...

  17. Detection of HbsAg and hATIII genetically modified goats (Caprahircus) by loop-mediated isothermal amplification.

    Science.gov (United States)

    Tao, Chenyu; Zhang, Qingde; Zhai, Shanli; Liu, Bang

    2013-11-01

    In this study, sensitive and rapid detection systems were designed using a loop-mediated isothermal amplification (LAMP) method to detect the genetically modified goats. A set of 4 primers were designed for each exogenous nucleic acids HBsAg and hATIII. The DNA samples were first amplified with the outer and inner primers and released a single-stranded DNA,of which both ends were stem-loop structure. Then one inner primer hybridized with the loop, and initiated displacement synthesis in less than 1 h. The result could be visualized by both agarose gel electrophoresis and unaided eyes directly after adding SYBR GREEN 1. The detection limit of LAMP was ten copies of target molecules, indicating that LAMP was tenfold more sensitive than the classical PCR. Furthermore, all the samples of genetically modified goats were tested positively by LAMP, and the results demonstrated that the LAMP was a rapid and sensitive method for detecting the genetically modified organism.

  18. Assessment of renal function with the Tc-99m-MAG3 clearance

    International Nuclear Information System (INIS)

    Keske, U.; Corcles, M.; Andreessen, R.; Wilfling, M.; Roll, D.; Gahl, G.; Felix, R.

    1990-01-01

    This paper evaluates the applicability of the 99m-Tc-mercaptoacetyle-triglycine (MAG3) clearance for the documentation of renal function. Renal clearance was measured with the method of Tauxe in 699 patients during routine renal scintigraphy with 80 MBq of 99mTc-MAG3. Serum creatinine level and MAG3 clearance show an inverse correlation. Patients with an elevated serum creatinine level constantly have a lowered MAG3 clearance and vice versa. For creatinine values lower than 1.8 mg/dL, minor changes in creatinine level are accompanied by large changes in MAG3 clearance. Age (in years) dependence of MAG3 clearance was evaluated in 487 patients who showed no evidence of impaired renal function

  19. Effects of heart rate on myocardial thallium-201 uptake and clearance

    International Nuclear Information System (INIS)

    Nordrehaug, J.E.; Danielsen, R.; Vik-Mo, H.

    1989-01-01

    The effects of heart rate on the myocardial uptake and clearance of 201 Tl were studied prospectively in seven healthy men, mean age 43 +/- 7 (s.d.) yr. Initial and delayed (3 hr) thallium images were obtained in three views after three bicycle exercise tests: to maximal, 80% and 60% of predicted maximal heart rate. The mean of three views initial myocardial 201 Tl uptake was higher at maximal than at both 80% and 60% of predicted maximal heart rate, being 81% (p less than 0.01) and 60% (p less than 0.01) of maximal activity, respectively. The myocardial activity in the delayed images was identical. There was a linear relationship between heart rate and the initial myocardial activity, r = 0.86 (p less than 0.001). The mean (range) 201 Tl clearance was 58% (51-65), 47% (34-56), and 34% (22-49) (all differences p less than 0.01), respectively. Concordance among the three individual views in estimating clearance was best for the highest exercise level. There was a linear relationship between heart rate and clearance, r = 0.80 (p less than 0.001). Clearance was altered by only 1.67 x 10%/heart bpm (0.024 hr/heart beat). Clearance in the liver, spleen and lungs increased at submaximal exercise levels. Thus, a linear relationship between heart rate and clearance is the result of changes in the initial exercise myocardial 201 Tl activity. Submaximal exercise may reduce reproducibility of clearance estimation, and the change of myocardial clearance with heart rate seems less than previously suggested

  20. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    shanker

    have been identified [1,3]. These include stone characteristics, the type of lithotripter used, LPC anatomy and body habitus. For iso- lated LPC stones, the pelvicalyceal angle, infundibulum length and width are considered important determinants for stone clearance. The impact of body habitus on stone clearance has so far ...

  1. Delayed clearance of triglyceride‐rich lipoproteins in young, healthy obese subjects†

    Science.gov (United States)

    Goll, R.; Lekahl, S.; Moen, O. S.; Florholmen, J.

    2015-01-01

    Summary Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age‐ and sex‐matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA‐IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA‐IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. PMID:26469529

  2. Delayed clearance of triglyceride-rich lipoproteins in young, healthy obese subjects.

    Science.gov (United States)

    Larsen, M A; Goll, R; Lekahl, S; Moen, O S; Florholmen, J

    2015-12-01

    Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age- and sex-matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA-IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA-IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. © 2015 World Obesity.

  3. Dynamic characteristics analysis of deployable space structures considering joint clearance

    Science.gov (United States)

    Li, Tuanjie; Guo, Jian; Cao, Yuyan

    2011-04-01

    The clearance in joints influences the dynamic stability and the performance of deployable space structures (DSS). A virtual experimental modal analysis (VEMA) method is proposed to deal with the effects of joint clearance and link flexibility on the dynamic characteristics of the DSS in this paper. The focus is on the finite element modeling of the clearance joint, VEMA and the modal parameters identification of the DSS. The finite element models (FEM) of the clearance joint and the deployable structure are established in ANSYS. The transient dynamic analysis is conducted to provide the time history data of excitation and response for the VEMA. The fast Fourier transform (FFT) technique is used to transform the data from time domain to frequency domain. The frequency response function is calculated to identify the modal parameters of the deployable structure. Experimental verification is provided to indicate the VEMA method is both a cost and time efficient approach to obtain the dynamic characteristics of the DSS. Finally, we analyze the effects of clearance size and gravity on the dynamic characteristics of the DSS. The analysis results indicate that the joint clearance and gravity strongly influence the dynamic characteristics of the DSS.

  4. 32 CFR 644.522 - Clearance of military scrap.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... destruction, by using command, of all military scrap and scrap metal from lands suitable for cultivation or...

  5. Applicability of Clearance Automatic Laser Inspection System to Clearance Measurement of Concrete Segments

    International Nuclear Information System (INIS)

    Sasaki, M.; Ogino, H.; Hattori, T.

    2009-01-01

    In the decommissioning of a nuclear power plant, large amounts of metal scrap and concrete segments require disposal when dismantling the nuclear reactor and surrounding facilities. When their activity level is negligible or sufficiently small, they can be regarded as general industrial waste. To distinguish between radioactive and nonradioactive materials, the clearance level for each radionuclide has been determined in units of activity concentration. These clearance levels are indicated in the International Atomic Energy Agency (IAEA) Safety Standards Series No. RS-G-1.7. The Japanese regulatory authority decided in 2005 to adopt the values given in RS-G-1.7 as clearance levels in legislation. Recently, a Clearance Automatic Laser Inspection System (CLALIS) has been developed utilizing gamma-ray measurement, automatic laser shape measurement and Monte Carlo calculation. CLALIS comprises four laser scanners and eight large plastic scintillation detectors surrounded by a 5-cm-thick lead shield. Using three-dimensional (3D) laser scanning, a measurement target, which is placed on the measuring tray, is represented as a dot image. The dot image is converted into voxels after noise removal, and is written in MCNP (A General Monte Carlo N-Particle Transport Code System) input files. When the gamma-ray measurement is carried out, the MCNP calculations are also carried out to obtain the calibration factor and background (BG) correction factors. For the clearance measurement of concrete segments, the effect of gamma-rays from natural radionuclides in the measurement target, such as K-40 and the radioactive decay products of Th-232 and U-238, should be taken into account to ensure adequate waste management. Since NE102A plastic scintillation detectors are used for gamma-ray measurement in CLALIS, it is impossible to distinguish between the count rates of natural radionuclides and contaminants on the basis of gamma-ray energy information. To overcome this problem, the

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast To learn more about how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist ...

  7. Clearance level and industrial waste management

    International Nuclear Information System (INIS)

    Asano, Toichi

    1999-01-01

    Defining the clearance level enables the radioactive waste with lower radioactivity than a certain level to be the general industrial waste and therefore consideration for public acceptance is essential. For this, it is necessary to understand laws concerning not only atomic power and radioactivity but also disposal and cleaning of general waste. It is also necessary that the waste below the clearance level should be as much as possible handled in the modern common concept of recycling of resources. In 1996, the weight of industrial waste was about 400 million tons, of which 40% was disposed by burning and dehydration, 39% was re-used and 21% was subjected to the final disposal like reclamation. Reduction, re-use and recycling of the generated waste are required for making the society with recycling of resources. Scrap concrete materials below the clearance level of 0.6 million tons are estimated to be generated by dismantling the light water reactor of 1 million kW output and profitable technology for recycling the scrap is under investigation. (K.H.)

  8. Factors Associated with Spontaneous Clearance of Hepatitis C Virus in Chinese Population

    Directory of Open Access Journals (Sweden)

    Fei Kong

    2014-01-01

    Full Text Available Hepatitis C virus (HCV infections spontaneously clear in approximately 15–45% of infected individuals. Factors which influence spontaneous HCV clearance remain to be identified. The purpose of the present study was to identify variables associated with spontaneous HCV clearance in a referred population of Chinese patients. The prevalence of host, viral, and environmental factors known to influence the outcome of HCV infections was compared in 92 HCV spontaneous clearance subjects and 318 HCV persistent infection subjects. Univariate and multivariate analyses were performed to identify those factors associated with spontaneous HCV clearance. In univariate analysis, female gender, a history of icteric hepatitis, serologic evidence of concurrent HBV infection, and rs12979860 CC genotype were positively associated with spontaneous HCV clearance, while alcohol consumption was negatively associated with clearance. In multivariate analysis, female gender, a history of icteric hepatitis, concurrent HBV infection, and rs12979860 CC genotype remained independent variables associated with spontaneous HCV clearance. Spontaneous HCV clearance is more likely to occur in females, subjects with a history of icteric hepatitis, HBV coinfections, and those with the rs12979860 CC genotype.

  9. Verification of surface contamination density standard using clearance automatic laser inspection system for objects from a nuclear power plant

    International Nuclear Information System (INIS)

    Sasaki, Michiya; Ogino, Haruyuki; Ichiji, Takeshi; Hattori, Takatoshi

    2008-01-01

    In the clearance level inspection in Japan, it is necessary to indicate that the activity level of the target object must be less than not only the clearance levels, but also the surface contamination density standards. The classification measurements for these two standards have been performed separately, and the GM survey meters based on beta-ray measurement have mainly been used for surface contamination density measurement so far. Recently the Clearance Automatic Laser Inspection System, named CLALIS, has been developed to estimate the low-level activity concentration. This system consists of 3-dimensional laser scanner for shape measurement and eight large NE102A plastic scintillation detectors for gamma-ray measurement, and it has been clarified that the CLALIS has adequate detection ability for clearance measurement of both metal scraps and concrete debris. In this study, we compared the surface contamination densities for a number of actual contaminated and non-contaminated objects generated inside from the radiation controlled area at the Kashiwazaki-Kariwa nuclear power station by using the CLALIS and the GM survey meter. As a result, since CLALIS could detect the surface contamination as well as the GM survey meter for all measurement targets, it was revealed that CLALIS can rationally achieve clearance level inspection in a single radiation measurement. The practicality of CLALIS in view of the detection limit and processing time was discussed by comparison with the usual radiation monitors for surface contamination measurement. (author)

  10. Hepatitis B virus infection among first-time blood donors in Italy: prevalence and correlates between serological patterns and occult infection.

    Science.gov (United States)

    Romanò, Luisa; Velati, Claudio; Cambiè, Giuseppe; Fomiatti, Laura; Galli, Claudio; Zanetti, Alessandro Remo

    2013-04-01

    A prospective, 1-year study was performed among Italian first-time, volunteer blood donors, who account for 12% of all donations, in order to assess the frequency and serological patterns of hepatitis B virus infection and the presence of occult infection. Consecutive donors (n=31,190) from 21 blood transfusion centres, from age classes not subjected to universal HBV vaccination, were tested for HBsAg and anti-HBc by commercial immunoassays. Other HBV serological markers were searched for and qualitative and quantitative assessments of HBV-DNA were made in HBsAg and/or anti-HBc-positive individuals. Of the 31,190 donors studied, 100 (0.32%) were positive for both HBsAg and anti-HBc, 2 for HBsAg (0.01%) alone, and 2,593 (8.3%) for anti-HBc. Of these last, 86.7% were also positive for anti-HBs (with or without anti-HBe), 2.9% were positive for anti-HBe without anti-HBs and 10.4% had no other HBV markers (anti-HBc alone). A general north-south increasing gradient of HBV prevalence was observed. Circulating HBV-DNA was found in 96.8% of HBsAg-positive subjects as compared to 0.55% (12/2,186) of anti-HBc-positive/HBsAg-negative subjects, with higher frequencies among anti-HBs-negative than among anti-HBs-positive ones (1.68% vs. 0.37%; p blood donors is much lower than in the past. The presence of occult infections in this group was confirmed (frequency: 1 in 2,599), supporting the hypothesis of long-term persistence of HBV infection after clearance of HBsAg. HBsAg and nucleic acid amplification testing for blood screening and vaccination against HBV are crucial in order to further reduce the risk of transfusion-transmitted HBV towards zero.

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage ...

  12. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  13. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, Anne Cathrine Roslev

    1984-01-01

    we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  14. Using Terrestrial Laser Scanners to Calculate and Map Vertical Bridge Clearance

    Science.gov (United States)

    Zhang, C.; Arditi, D.; Chen, Z.

    2013-08-01

    The vertical clearance of a bridge over a highway is important in preventing oversized vehicles from hitting the bridge. The vertical clearance of a bridge is traditionally measured by using surveying equipment such as leveling rods and total stations. Typically, measurements are taken at multiple locations in order to determine the minimum vertical clearance under the bridge. This process is time and labor consuming. Also, these measurements may not be accurate because of the traffic, the uneven surface, and the reading error caused by the surveyor. Additionally, when one is faced with a multitude of reports especially in large projects with multiple ramps and bridges, it is not easy and it often takes a long time to find the bridge under study. This research provides a highly accurate measurement of the vertical bridge clearance by using terrestrial laser scanners. The clearance can be measured in the office by processing the collected point cloud data. The minimum vertical clearance is easily identified and the measurement is visualized and geo-referenced. An approach to reduce data noise caused by traffic is also introduced in this study. In addition, to help reduce the confusion of finding the bridge under study and to facilitate access to the clearance data, the clearance measurements are geo-referenced to an online mapping system. This system allows access to the final deliverable very easily through a single web portal. Finally, Illinois Department of Transportation's Circle Interchange is used to demonstrate this new method.

  15. Mohs micrographic surgery in dermatofibrosarcoma protuberans allows tumour clearance with smaller margins and greater preservation of healthy tissue compared with conventional surgery: a study of 74 primary cases.

    Science.gov (United States)

    Serra-Guillén, C; Llombart, B; Nagore, E; Guillén, C; Requena, C; Traves, V; Kindem, S; Alcalá, R; Rivas, N; Sanmartín, O

    2015-01-01

    Dermatofibrosarcoma protuberans (DFSP) is an uncommon skin tumour with aggressive local growth. Whether DFSP should be treated with conventional surgery (CS) or Mohs micrographic surgery (MMS) has long been a topic of debate. To calculate, in a large series of DFSP treated by MMS, the minimum margin that would have been needed to achieve complete clearance by CS. Secondly, to calculate the percentage of healthy tissue that was preserved by MMS rather than CS with 2- and 3-cm margins. The minimum margin was calculated by measuring the largest distance from the visible edge of the tumour to the edge of the definitive surgical defect. Tumour and surgical defect areas for hypothetical CS with 2- and 3-cm margins were calculated using AutoCAD for Windows. A mean minimum margin of 1·34 cm was required to achieve complete clearance for the 74 tumours analysed. The mean percentages of skin spared using MMS rather than CS with 2- and 3-cm margins were 49·4% and 67·9%, respectively. MMS can achieve tumour clearance with smaller margins and greater preservation of healthy tissue than CS. © 2014 British Association of Dermatologists.

  16. Respiratory clearance of aerosolized radioactive solutes of varying molecular weight

    International Nuclear Information System (INIS)

    Huchon, G.J.; Montgomery, A.B.; Lipavsky, A.; Hoeffel, J.M.; Murray, J.F.

    1987-01-01

    To determine the influence of varying molecular weight (mol wt) on respiratory clearance of aerosolized solutes, we studied eight radiopharmaceuticals, each administered to four dogs: sodium /sup 99m/Tc pertechnetate (TcO4), /sup 99m/Tc glucoheptonate ([/sup 99m/Tc]GH), 51Cr-ethylenedinitrotetraacetate ([51Cr]EDTA), /sup 99m/Tc diethylenetriaminepentaacetate ([99mTc] DTPA), 111 In diethylenetriaminepentaacetate ([ 111 In]DTPA), 67 Ga desferoxaminemesylate ([ 67 Ga]DFOM), /sup 99m/Tc dextran ([/sup 99m/Tc]DX) and 111 In transferrin ([ 111 In]TF). After aerosolization (0.8 m MMD, 2.4 GSD), clearance was determined for 30 min and then corrected by intravenous injection for nonairspace radioactivity. In-TF clearance (0.11 +/- 0.10%/min) was lower than TcO4 (6.32 +/- 0.62%/min), [/sup 99m/Tc]GH (1.50 +/- 0.37%/min), [ 51 Cr]EDTA (2.38 +/- 1.02%/min), [/sup 99m/Tc]DTPA (3.51 +/- 0.40%/min), [ 111 In]DTPA (2.35 +/- 0.42%/min), [ 67 Ga] DFOM (1.99 +/- 0.49%/min) and [/sup 99m/Tc]DX (1.81 +/- 0.75%/min) clearances (p less than 0.001). TcO4 clearance was higher than others (p less than 0.001). Technetium binding to DX was unsatisfactory; aerosolization caused unbinding from DTPA. We conclude that respiratory clearance of large mol wt solutes within 30 min is negligible and, that clearance of molecules between 347-5099 daltons differs greatly, suggesting that binding and/or intrapulmonary retention affect transfer

  17. Comparison of German and international clearance regulations - chances and limits for harmonization

    International Nuclear Information System (INIS)

    Thierfeldt, S.; Schartmann, F.

    2005-01-01

    The regulations on clearance in the German nuclear regulatory framework (especially sect. 29 and Annexes III and IV of the Radiation Protection Ordinance) are comprehensive and well founded. Germany has developed some of its clearance levels in advance of recommendations issued by the EC. Therefore, there are differences between the German and international clearance regulations. That has been investigated by a working group on clearance of the German Commission on Radiological Protection (SSK) which has performed an analysis of differences and their reasons for clearance levels in Germany and other countries (UK, The Netherlands, Sweden, USA and others). Differences can mainly be explained by country specific approaches in scenarios. Differences especially for the most relevant nuclides are not significant from a radiological point of view. The level of radiological protection (trivial dose range, a few 10 μSv/a) is guaranteed in all countries. The international discussion on the international harmonisation of clearance levels (mainly within the scope of the OECD/NEA and IAEA) can be enlightened on the basis of these results. This discussion concentrates on the question how far a harmonisation of clearance level values is actually necessary and possible. The IAEA Safety Guide RS-G-1.7 'Application of the concepts of exclusion, exemption and clearance' is of particular importance, because it proposes a set of values which might in the long-term take the role of international unconditional clearance levels. International harmonisation is only relevant for unconditional clearance of those materials, which are traded in large quantities among countries, in particular metal scrap. Harmonisation of the values to the same order of magnitude is sufficient. (orig.)

  18. Discrepancy between circadian rhythms of inulin and creatinine clearance

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; Krediet, R. T.; Arisz, L.

    1992-01-01

    To elucidate the disparity between circadian rhythmicity of inulin and creatinine clearance, we simultaneously measured inulin and creatinine clearances every 3 hours during 1 day in 14 normal subjects and in 8 patients with nephrotic syndrome. All patients and normal subjects had a circadian rhythm

  19. Lung clearance of 99m Tc- DTPA in systemic lupus erythematous

    International Nuclear Information System (INIS)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T.; Cunha, R.D.; Marroni, B.J.

    2002-01-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... cystic fibrosis. CF CARE CENTER finder We provide funding for and accredit more than 120 care centers ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  1. Enrichment of Ly6Chi monocytes by multiple GM-CSF injections with HBV vaccine contributes to viral clearance in a HBV mouse model.

    Science.gov (United States)

    Zhao, Weidong; Zhou, Xian; Zhao, Gan; Lin, Qing; Wang, Xianzheng; Yu, Xueping; Wang, Bin

    2017-12-02

    Adjuvants are considered a necessary component for HBV therapeutic vaccines but few are licensed in clinical practice due to concerns about safety or efficiency. In our recent study, we established that a combination protocol of 3-day pretreatments with GM-CSF before a vaccination (3 × GM-CSF+VACCINE) into the same injection site could break immune tolerance and cause over 90% reduction of HBsAg level in the HBsAg transgenic mouse model. Herein, we further investigated the therapeutic potential of the combination in AAV8-1.3HBV-infected mice. After 4 vaccinations, both serum HBeAg and HBsAg were cleared and there was a 95% reduction of HBV-positive hepatocytes, in addition to the presence of large number of infiltrating CD8 + T cells in the livers. Mechanistically, the HBV-specific T-cell responses were elicited via a 3 × GM-CSF+VACCINE-induced conversion of CCR2-dependent CD11b + Ly6C hi monocytes into CD11b + CD11c + DCs. Experimental depletion of Ly6C hi monocytes resulted in a defective HBV-specific immune response thereby abrogating HBV eradication. This vaccination strategy could lead to development of an effective therapeutic protocol against chronic HBV in infected patients.

  2. 48 CFR 32.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  3. 48 CFR 832.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  4. Secretion clearance strategies in Australian and New Zealand Intensive Care Units.

    Science.gov (United States)

    Ntoumenopoulos, George; Hammond, Naomi; Watts, Nicola R; Thompson, Kelly; Hanlon, Gabrielle; Paratz, Jennifer D; Thomas, Peter

    2017-06-26

    To describe the processes of care for secretion clearance in adult, intubated and mechanically ventilated patients in Australian and New Zealand Intensive Care Units (ICUs). A prospective, cross-sectional study was conducted through the Australian and New Zealand Intensive Care Society Clinical Trials Group (ANZICS CTG) Point Prevalence Program. Forty-seven ICUs collected data from 230 patients intubated and ventilated on the study day. Secretion clearance techniques beyond standard suctioning were used in 84/230 (37%) of patients during the study period. Chest wall vibration 34/84 (40%), manual lung hyperinflation 24/84 (29%), chest wall percussion 20/84 (24%), postural drainage/patient positioning 17/84 (20%) and other techniques including mobilisation 15/84 (18%), were the most common secretion clearance techniques employed. On average (SD), patients received airway suctioning 8.8 (5.0) times during the 24-h study period. Mucus plugging events were infrequent (2.7%). The additional secretion clearance techniques were provided by physiotherapy staff in 24/47 (51%) ICUs and by both nursing and physiotherapy staff in the remaining 23/47 (49%) ICUs. One-third of intubated and ventilated patients received additional secretion clearance techniques. Mucus plugging events were infrequent with these additional secretion clearance approaches. Prospective studies must examine additional secretion clearance practices, prevalence of mucus plugging episodes and impact on patient outcomes. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  5. Factors contributing to delay in parasite clearance in uncomplicated falciparum malaria in children

    Directory of Open Access Journals (Sweden)

    Sijuade Abayomi

    2010-02-01

    Full Text Available Abstract Background Drug resistance in Plasmodium falciparum is common in many endemic and other settings but there is no clear recommendation on when to change therapy when there is delay in parasite clearance after initiation of therapy in African children. Methods The factors contributing to delay in parasite clearance, defined as a clearance time > 2 d, in falciparum malaria were characterized in 2,752 prospectively studied children treated with anti-malarial drugs between 1996 and 2008. Results 1,237 of 2,752 children (45% had delay in parasite clearance. Overall 211 children (17% with delay in clearance subsequently failed therapy and they constituted 72% of those who had drug failure, i.e., 211 of 291 children. The following were independent risk factors for delay in parasite clearance at enrolment: age less than or equal to 2 years (Adjusted odds ratio [AOR] = 2.13, 95% confidence interval [CI]1.44-3.15, P 50,000/ul (AOR = 2.21, 95% CI = 1.77-2.75, P 20000/μl a day after treatment began, were independent risk factors for delay in clearance. Non-artemisinin monotherapies were associated with delay in clearance and treatment failures, and in those treated with chloroquine or amodiaquine, with pfmdr 1/pfcrt mutants. Delay in clearance significantly increased gametocyte carriage (P Conclusion Delay in parasite clearance is multifactorial, is related to drug resistance and treatment failure in uncomplicated malaria and has implications for malaria control efforts in sub-Saharan Africa.

  6. Effect of glucose-insulin-potassium infusion on thallium myocardial clearance

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Factors influencing the rate of 201 Tl clearance from the myocardium have not been clearly defined. This study determined the effect of an intravenous infusion of glucose-insulin-potassium (GIK) on the net 201 Tl clearance rates from myocardium with and without initial 201 Tl loading. Anesthetized open-chest dogs underwent 5 min of left anterior descending coronary artery occlusion and intravenous 201 Tl was injected and the occlusion released 5 min later. Thirty minutes after 201 Tl injection, 30 ml of either GIK (nine dogs) or saline (five dogs) was infused intravenously. The clearance rates of 201 Tl from the anterior wall (without initial 201 Tl loading) and from the posterior wall (with initial 201 Tl loading) were monitored with miniaturized cadmium telluride detectors placed on the myocardium. Calculation of net myocardial clearance rates was performed by linear regression analysis from serial 1 min counts. Compared with saline infusion, GIK increased the net clearance of 201 Tl from both myocardial regions with and without initial loading. The most marked change induced by GIK infusion was in the myocardial region without initial 201 Tl loading; a net increase in 201 Tl activity (72 +/- 42 cpm/30 min) was converted into a net loss (-594 +/- 228 cpm/30 min). There was no significant change in 201 Tl clearance after the saline infusion. Heart rate, aortic and left atrial pressure, sonomicrometer-measured transmural myocardial wall thickness, microsphere-determined myocardial blood flow, and blood glucose and potassium concentrations did not change significantly during GIK or saline infusions. Thus, GIK infusion appears to increase net 201 Tl clearance from myocardial zones with and without initial 201 Tl loading

  7. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  8. 48 CFR 1432.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  9. Determining vancomycin clearance in an overweight and obese population.

    Science.gov (United States)

    Leong, Julie V B; Boro, Maureen S; Winter, Michaele

    2011-04-01

    Two methods of calculating vancomycin clearance were compared to determine the best body weight measure to use when dosing vancomycin for overweight and obese patients. Hospitalized veterans weighing more than 120% of their ideal body weight (IBW) with serum vancomycin concentrations (SVCs) drawn between January 1, 2003, and June 30, 2005, were eligible for study inclusion. Exclusion criteria included weight of more than 300% the IBW, unstable renal function, dialysis, uncertain vancomycin dosing or sampling times, and distribution-phase sampling. Data from January 1 through December 31, 2003 (phase 1) determined the best-fit weight for vancomycin clearance for the Leonard and Boro method. The bias and precision of the modified Leonard and Boro method using the best-fit weight for vancomycin clearance were then compared with those of the Rushing and Ambrose method for predicting SVCs from January 1, 2004, through June 30, 2005 (phase 2). Forty-eight patients were included in phase 1, with 67 SVCs for analysis. During phase 1, adjusted body weight (ABW), using the Leonard and Boro method, was superior in predicting vancomycin clearance and the resultant SVCs. A total of 96 patients were included in phase 2 of the study, with 160 SVCs for analysis. The modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting vancomycin clearance. Use of ABW proved to be superior compared with total body weight when estimating vancomycin clearance in overweight and obese patients. While there was no difference in bias between methods, the modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting SVCs when dosing vancomycin for obese patients.

  10. Tip clearance effect on through-flow and performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Young Seok; Kang, Shin Hyoung

    2004-01-01

    Numerical simulations have been performed to investigate tip clearance effect on through-flow and performance of a centrifugal compressor which has the same configuration of impeller with six different tip clearances. Secondary flow and loss distribution have been surveyed to understand the flow mechanism due to the tip clearance. Tip leakage flow strongly interacts with mainstream flow and considerably changes the secondary flow and the loss distribution inside the impeller passage. A method has been described to quantitatively estimate the tip clearance effect on the performance drop and the efficiency drop. The tip clearance has caused specific work reduction and additional entropy generation. The former, which is called inviscid loss, is independent of any internal loss and the latter, which is called viscous loss, is dependent on every loss in the flow passage. Two components equally affected the performance drop as the tip clearances were small, while the efficiency drop was influenced by the viscous component alone. The additional entropy generation was modeled with all the kinetic energy of the tip leakage flow. Therefore, the present paper can provide how to quantitatively estimate the tip clearance effect on the performance and efficiency

  11. Tear clearance implications for ocular surface health.

    Science.gov (United States)

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  12. Clearance of Tc-99m DTPA in hemodialysis and peritoneal dialysis: concise communication

    International Nuclear Information System (INIS)

    Wainer, E.; Boner, G.; Lubin, E.; Rosenfeld, J.B.

    1981-01-01

    The clearance of Tc-99m DTPA was studied in 14 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD). Mean Tc-99m DTPA clearance during HD was 37.8% +/- 10.1 of creatinine clearance. Mean Tc-99m DTPA clearance in PD was 65.1% +/- 10.3 of creatinine clearance. Tc-99m DTPA, with a larger molecular weight than that of creatinine, is cleared relatively better during PD than during HD. Thus Tc-99m DTPA may be used in the assessment of the effectiveness of different dialytic treatments for substances of similar molecular weight. In addition, our study shows that clearance of DTPA both in HD and PD is sufficiently high to allow the removal of this chelating agent in patients with renal failure

  13. Effect of isolated hepatic ischemia on organic anion clearance and oxidative metabolism.

    Science.gov (United States)

    Minard, G; Bynoe, R; Wood, G C; Fabian, T C; Croce, M; Kudsk, K A

    1992-04-01

    Hepatic failure is frequently seen following severe hemorrhagic shock, sepsis, and trauma. Clearance of various drugs has been used to evaluate hepatocellular dysfunction, including indocyanine green (ICG), an organic anionic dye that is transported similarly to bilirubin, and antipyrine (AP), a marker of oxidative phosphorylation. Previous investigators have noted a decrease in ICG excretion following systemic hemorrhage. The effect of isolated hepatic ischemia on the clearances of ICG and AP was studied in 16 pigs after 90 minutes of vascular occlusion to the liver. Antipyrine clearance decreased almost 50% from baseline values at 24 and 72 hours after the ischemia procedure, indicating a significant depression in the cytochrome P-450 system. On the other hand, ICG clearance did not change significantly. In conclusion, ICG clearance is not depressed after isolated hepatic ischemia in pigs. Changes in organic anion clearance after systemic hemorrhage may be because of release of toxic products from ischemic peripheral tissue.

  14. Clearance of 99mTc-DTPA and experimentally increased alveolar surfactant content

    International Nuclear Information System (INIS)

    Bos, J.A.H.; Wollmer, P.; Bakker, W.; Hannappel, E.; Lachmann, B.

    1992-01-01

    The authors measured clearance of 99m Tc-labeled diethylenetriamine pentaacetic acid ( 99m Tc-DTPA) in rabbits with experimentally increased alveolar surfactant content. In one group of animals, surfactant production was increased by treatment with ambroxol, and another group of animals was treated with tracheal instillation of natural surfactant. A group of untreated control animals and animals treated with instillation of saline were also studied. Clearance was measured during standard conditions of mechanical ventilation and during ventilation with large tidal volumes. In ambroxol- and surfactant-treated groups, clearance rate was reduced compared with untreated control animals. In contrast, clearance rate increased after saline instillation. The differences were observed at both modes of ventilation. The findings indicate that the pulmonary surfactant system is a rate-limiting factor for the clearance of 99m Tc-DTPA and that the volume dependence of clearance is not explained by stretching of the alveolar wall only. 28 refs., 2 figs., 1 tab

  15. Reprocessing and clearance as ways for reducing radioactive waste from fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Rocco, P.; Zucchetti, M. [Energetics Dept., Polytechnic of Turin (Italy); Zucchetti, M. [European Commission, JRC, Institute for Advanced Material, Ispra, Vatican City State, Holy See (Italy)

    1998-07-01

    The irradiated material chosen to investigate this concept is V-4Cr-4Ti, used as in-vessel structural material of PM-1, one of the three reactor models of SEAFP-2 assessments. The analysis performed deserves the following comments: in general, the modified concentrations of the parent isotopes have been assumed equal to the actual detection limits of the concerned elements. The nuclides investigated are those having the higher activities in the irradiated alloy (dominant nuclides). The contribution to the clearance index of other nuclides, present in the irradiated alloy and not yet examined should also be assessed. Even having reduced the concentrations of the impurities to the very low levels hypothesized, the ratios (A/L{sub c}){sub m} of some nuclides are too great. Beside K-42 and Ar-42, deriving from titanium, this happens for nuclides deriving from niobium, silver, nickel, copper, strontium. Hence the clearance index of the modified alloy is greater than the unity and clearance conditions are not achieved. Additional purification process have to be envisaged after the irradiation, with an elemental dilution of the noxious nuclides and then performing a purification process. As an example, it is found from table 2 that the sum of the ratios (A/L{sub c}){sub m} of Nb-93m, Nb-91 and Nb-94, nuclides deriving from a concentration of 2 x 10{sup -2} ppm of niobium, is 7.75. An addition of 5/10 ppm of natural niobium to the molten irradiated material and a further purification of niobium to levels near to the initial one could achieve a 100-fold reduction of the ratios (A/L{sub c}){sub m}. 10000 t of V-4Cr4Ti, representing the total amount (maintenance + decommissioning) arising from the in vessel structures of a power reactor should be reprocessed with 100 kg of niobium, in the highly conservative hypothesis that all material is irradiated in first wall conditions. The secondary waste arising from the purification processes would not exceed a few ton which could be

  16. Domiciliary humidification improves lung mucociliary clearance in patients with bronchiectasis.

    Science.gov (United States)

    Hasani, A; Chapman, T H; McCool, D; Smith, R E; Dilworth, J P; Agnew, J E

    2008-01-01

    Inspired air humidification has been reported to show some benefit in bronchiectatic patients. We have investigated the possibility that one effect might be to enhance mucociliary clearance. Such enhancement might, if it occurs, help to lessen the risks of recurrent infective episodes. Using a radioaerosol technique, we measured lung mucociliary clearance before and after 7 days of domiciliary humidification. Patients inhaled high flow saturated air at 37 degrees C via a patient-operated humidification nasal inhalation system for 3 h per day. We assessed tracheobronchial mucociliary clearance from the retention of (99m)Tc-labelled polystyrene tracer particles monitored for 6 h, with a follow-up 24-h reading. Ten out of 14 initially recruited patients (age 37-75 years; seven females) completed the study (two withdrew after their initial screening and two prior to the initial clearance test). Seven patients studied were non-smokers; three were ex-smokers (1-9 pack-years). Initial tracer radioaerosol distribution was closely similar between pre- and post-treatment. Following humidification, lung mucociliary clearance significantly improved, the area under the tracheobronchial retention curve decreased from 319 +/- 50 to 271 +/- 46%h (p humidification treatment improved lung mucociliary clearance in our bronchiectatic patients. Given this finding plus increasing laboratory and clinical interest in humidification mechanisms and effects, we believe further clinical trials of humidification therapy are desirable, coupled with analysis of humidification effects on mucus properties and transport.

  17. 48 CFR 245.7101-4 - DD Form 1640, Request for Plant Clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false DD Form 1640, Request for Plant Clearance. 245.7101-4 Section 245.7101-4 Federal Acquisition Regulations System DEFENSE... Forms 245.7101-4 DD Form 1640, Request for Plant Clearance. Use to request plant clearance assistance or...

  18. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry

    Science.gov (United States)

    Black, A.; Evans, J. C.; Hadfield, Esme H.; Macbeth, R. G.; Morgan, A.; Walsh, M.

    1974-01-01

    Black, A., Evans, J. C., Hadfield, Esme H., Macbeth, R. G., Morgan, A., and Walsh, M. (1974).British Journal of Industrial Medicine,31, 10-17. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry. Measurements of mucociliary clearance from the anterior end of the middle turbinate were made using technetium-99m-labelled particles in nine woodworkers from the furniture industry and in 12 controls, none of whom had been occupationally exposed to wood dust. Clearance rates in the controls ranged from 1·9 to 18·5 mm min-1 with a mean of 6·8. These values are in good agreement with measurements reported elsewhere for normal subjects. Only one of the woodworkers had a clearance rate which fell within the normal range and he had been occupationally exposed for the shortest period (6 years). In four woodworkers clearance was very slow (furniture industry for more than 10 years. PMID:4821406

  19. Renal clearance of 99mTc-methylene-diphosphonate in human beings

    International Nuclear Information System (INIS)

    Vattimo, A.

    1987-01-01

    The renal clearance of 99m Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of 51 Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the 99m Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion. (orig.) [de

  20. Exercise increases the lung clearance of inhaled Tc-99m DTPA

    International Nuclear Information System (INIS)

    Meignan, M.; Rosso, J.; Cinotti, L.; Galle, P.

    1985-01-01

    It has been suggested that blood flow have little effect on the lung clearance of Tc-99m DTPA which depends on the alveolar distension. However an increase of pulmonary blood flow, induces a recruitment of new vascular areas which can enhance this clearance. To assess this hypothesis the pulmonary apical and basal clearances of a sumicronic aerosol of Tc-99m DTPA were studied at rest and at exercise in seven non smoking volunteers in upright posture. As a matter of fact exercising upright is known to increase primarily the apical blood flow. After inhalation the subjects were seated on a bicycle their back against a gamma camera which was linked to a computer. The lung radioactivity was registered successively during a resting and an exercising period. At rest there was a gradient of clearance from the apex to the base of the lung, the apical clearance being significantly higher. At exercise (50 Watts, 60 c. min /sup -1/, 7 min.) this regional gradient was enhanced by a large and significant increase of the apical clearances (0.0340 min /sup -1/ +-0.0063 SD versus 0.00183 min /sup -1/ +- 0.074 SD at rest, n = 7, p < 0.01). By contrast the changes of the basal clearances were slight and unsignificant (0.0146 min /sup -1/ +- 0.0062 SD versus 0.0140 min /sup -1/ +- 0.0082 SD). Since exercise induces little distension of the apical alveoli but drastically enhances the apical blood flow, the observed increase of the apical lung clearance could be primarily attributed to the recruitment of new capillaries induced by exercise in the apices. This led to an increase of the surface area permeability product

  1. Oxygen Tension Beneath Scleral Lenses of Different Clearances.

    Science.gov (United States)

    Giasson, Claude J; Morency, Jeanne; Melillo, Marc; Michaud, Langis

    2017-04-01

    To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

  2. Acute exposure to acid fog. Effects on mucociliary clearance

    International Nuclear Information System (INIS)

    Laube, B.L.; Bowes, S.M. III; Links, J.M.; Thomas, K.K.; Frank, R.

    1993-01-01

    Submicrometric sulfuric acid (H2SO4) aerosol can affect mucociliary clearance without eliciting irritative symptoms or changes in pulmonary function. The effect of larger fog droplets containing H2SO4 on mucociliary clearance is unknown. We quantified mucociliary clearance from the trachea (n = 4) and small airways (n = 7) of young healthy male adults after an acute exposure to H2SO4 fog (MMAD = 10.3 microns; pH = 2.0; liquid water content = 481 +/- 65 mg/m3; osmolarity = 30 mOsm). Acid fog (AF) or saline fog (SF) (10.9 microns; 492 +/- 116 mg/m3; 30 mOsm) was administered for 40 min of unencumbered breathing (no mouth-piece) at rest and for 20 min of exercise sufficient to produce oronasal breathing. Fog exposures were followed by a methacholine (MCh) challenge (a measure of airway reactivity) or inhalation of technetium-99M radioaerosol (MMAD = 3.4 microns) on 2 study days each. Changes in symptoms and forced ventilatory function were also assessed. Clearance was quantified from computer-assisted analyses of gamma camera images of the lower respiratory tract in terms of %removal/min of the radiolabel from the trachea 25 min after inhalation and from the outer zone of the right lung after 1.9 to 3 h. Symptoms, forced ventilatory function, and MCh response were unaffected by either fog. Tracheal clearance was more rapid in four of four subjects after AF (0.83 +/- 1.58% removal/min) compared with that after SF (-0.54 +/- 0.85% removal/min). Outer zone clearance was more rapid in six of seven subjects after AF (0.22 +/- 0.15% removal/min) compared with that after SF (0.01 +/- 0.09% removal/min)

  3. 20 CFR 655.150 - Interstate clearance of job order.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  4. Dimerization of glycoprotein Ibα is not sufficient to induce platelet clearance.

    Science.gov (United States)

    Liang, X; Syed, A K; Russell, S R; Ware, J; Li, R

    2016-02-01

    ESSENTIALS: Many anti-glycoprotein (GP)Ibα antibodies induce platelet clearance in a dimer-dependent manner. Characterization of monoclonal antibodies that bind the mechanosensitive domain (MSD) of GPIbα. An anti-MSD antibody binds two copies of GPIbα in platelets but does not induce platelet clearance. The prevailing clustering model of GPIbα signaling is incorrect or needs revision. The mechanism of platelet clearance is not clear. Many antibodies binding the membrane-distal ligand-binding domain of glycoprotein (GP)Ibα induce rapid clearance of platelets and acute thrombocytopenia, which requires the bifurcated antibody structure. It was thought that binding of these antibodies induced lateral dimerization or clustering of GPIbα in the plasma membrane, which leads to downstream signaling and platelet clearance. However, many antibodies targeting GPIbβ and GPIX, which are associated with GPIbα in the GPIb-IX complex, do not induce platelet clearance, which is in contradiction to the clustering model. To test whether dimerization or clustering of GPIbα is sufficient to transmit the signal that leads to platelet clearance. We have recently raised several mAbs targeting the mechanosensitive domain (MSD) of GPIbα. Binding of these anti-MSD antibodies was characterized with biochemical methods. Their ability to stimulate platelets and induce platelet clearance in mice was assessed. Infusion of anti-MSD antibodies does not cause thrombocytopenia in mice. These antibodies show no detectable effects on platelet activation and aggregation in vitro. Further biochemical investigation showed that the anti-MSD antibody 3D1 binds two copies of GPIbα on the platelet surface. Therefore, lateral dimerization of GPIbα induced by antibody binding is not sufficient to initiate GPIb-IX signaling and induce platelet clearance. Our results suggest that a factor other than or in addition to clustering of GPIbα is required to induce platelet clearance. © 2015 International

  5. HPT Clearance Control: Intelligent Engine Systems-Phase 1

    Science.gov (United States)

    2005-01-01

    The following work has been completed to satisfy the Phase I Deliverables for the "HPT Clearance Control" project under NASA GRC's "Intelligent Engine Systems" program: (1) Need for the development of an advanced HPT ACC system has been very clearly laid out, (2) Several existing and potential clearance control systems have been reviewed, (3) A scorecard has been developed to document the system, performance (fuel burn, range, payload, etc.), thermal, and mechanical characteristics of the existing clearance control systems, (4) Engine size and flight cycle selection for the advanced HPT ACC system has been reviewed with "large engine"/"long range mission" combination showing the most benefit, (5) A scoring criteria has been developed to tie together performance parameters for an objective, data driven comparison of competing systems, and (6) The existing HPT ACC systems have been scored based on this scoring system.

  6. 32 CFR 154.16 - Security clearance.

    Science.gov (United States)

    2010-07-01

    ... part. The Director, Washington Headquarters Services (WHS) will initiate the required investigation... clearance, as appropriate. The Assistant Secretary of Defense (Legislative Affairs) will be notified by WHS...

  7. Estimation of normal chromium-51 ethylene diamine tetra-acetic acid clearance in children

    International Nuclear Information System (INIS)

    Piepsz, A.; Pintelon, H.; Ham, H.R.

    1994-01-01

    In order to estimate the normal range of chromium-51 ethylene diamine tetra-acetic acid (EDTA) clearance in children, we selected a series of 256 patients with past or present urinary tract infection who showed, at the time of the clearance determination, normal technetium-99m dimercaptosuccinic acid (DMSA) scintigraphy and normal left to right DMSA relative uptake. The clearance was calculated by means of either the simplified second exponential method or the 120-min single blood sample; Chantler's correction was used in order to correct for having neglected the first exponential. There was a progressive increase in clearance from the first weeks of life (mean value around 1 month: 55 ml/min/1.73 m 2 ), with a plateau at around 18 months. Between 2 and 17 years of age, the clearance values remained constant, with a mean value of 114 ml/min/1.73 m 2 (SD: 24 ml/min); this is similar to the level described for inulin clearance. No significant differences were observed between boys and girls, or between clearance values calculated with one or with two blood samples. Taking into account the hour of intravenous injection of the tracer, we did not observe any influence of the lunchtime meal on the distribution of the 51 Cr-EDTA clearance values. (orig.)

  8. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    International Nuclear Information System (INIS)

    Vissing, J.; Ohkuwa, Tetsuo; Ploug, T.; Galbo, H.

    1988-01-01

    In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[ 3 H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared with nonimmobilized control rats. During running, glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always similar in the two groups and decreased during exercise. Intracellular nonphosphorylated 2DG was present in tissues with high glucose clearances. In conclusion, 42 h of immobilization markedly impairs glucose clearance of resting red muscle fibers in vivo. Apparently, physical inactivity in particular affects steps involved in insulin-mediated action that are not part of contraction-induced glucose uptake and metabolism. Presence of intracellular 2DG shows that separate determination of phosphorylated 2DG is necessary for accurate estimates of glucose metabolism and that accumulation of phosphorylated 2DG does not accurately reflect glucose transport

  9. Analysis of foot clearance in firefighters during ascent and descent of stairs.

    Science.gov (United States)

    Kesler, Richard M; Horn, Gavin P; Rosengren, Karl S; Hsiao-Wecksler, Elizabeth T

    2016-01-01

    Slips, trips, and falls are a leading cause of injury to firefighters with many injuries occurring while traversing stairs, possibly exaggerated by acute fatigue from firefighting activities and/or asymmetric load carriage. This study examined the effects that fatigue, induced by simulated firefighting activities, and hose load carriage have on foot clearance while traversing stairs. Landing and passing foot clearances for each stair during ascent and descent of a short staircase were investigated. Clearances decreased significantly (p < 0.05) post-exercise for nine of 12 ascent parameters and increased for two of eight descent parameters. Load carriage resulted in significantly decreased (p < 0.05) clearance over three ascent parameters, and one increase during descent. Decreased clearances during ascent caused by fatigue or load carriage may result in an increased trip risk. Increased clearances during descent may suggest use of a compensation strategy to ensure stair clearance or an increased risk of over-stepping during descent. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... NACFC Carolyn and C Richard Mattingly Leadership in Mental Health Care Award Mary M. Kontos Award NACFC Reflections ... help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. ... Instagram Email Find a Clinical Trial Help us blaze ...

  11. 7 CFR 1927.53 - Costs of title clearance and closing of transactions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Costs of title clearance and closing of transactions... and Loan Closing § 1927.53 Costs of title clearance and closing of transactions. The borrower or the... payment of all costs of title clearance and closing of the transaction and will arrange for payment before...

  12. Experimental Investigation of Factors Influencing Operating Rotor Tip Clearance in Multistage Compressors

    Directory of Open Access Journals (Sweden)

    Reid A. Berdanier

    2015-01-01

    Full Text Available An analysis of compressor rotor tip clearance measurements using capacitance probe instrumentation is discussed for a three-stage axial compressor. Thermal variations and centrifugal effects related to rotational speed changes affect clearance heights relative to the assembled configuration. These two primary contributions to measured changes are discussed both independently and in combination. Emphasis is given to tip clearance changes due to changing loading condition and at several compressor operating speeds. Measurements show a tip clearance change approaching 0.1 mm (0.2% rotor span when comparing a near-choke operating condition to a near-stall operating condition for the third stage. Additional consideration is given to environmental contributions such as ambient temperature, for which changes in tip clearance height on the order of 0.05 mm (0.1% rotor span were noted for temperature variations of 15°C. Experimental compressor operating clearances are presented for several temperatures, operating speeds, and loading conditions, and comparisons are drawn between these measured variations and predicted changes under the same conditions.

  13. USING TERRESTRIAL LASER SCANNERS TO CALCULATE AND MAP VERTICAL BRIDGE CLEARANCE

    OpenAIRE

    C. Zhang; D. Arditi; Z. Chen

    2013-01-01

    The vertical clearance of a bridge over a highway is important in preventing oversized vehicles from hitting the bridge. The vertical clearance of a bridge is traditionally measured by using surveying equipment such as leveling rods and total stations. Typically, measurements are taken at multiple locations in order to determine the minimum vertical clearance under the bridge. This process is time and labor consuming. Also, these measurements may not be accurate because of the traffi...

  14. Brain-wide pathway for waste clearance captured by contrast-enhanced MRI

    OpenAIRE

    Iliff, Jeffrey J.; Lee, Hedok; Yu, Mei; Feng, Tian; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2013-01-01

    The glymphatic system is a recently defined brain-wide paravascular pathway for cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange that facilitates efficient clearance of solutes and waste from the brain. CSF enters the brain along para-arterial channels to exchange with ISF, which is in turn cleared from the brain along para-venous pathways. Because soluble amyloid β clearance depends on glymphatic pathway function, we proposed that failure of this clearance system contributes t...

  15. Gamma-variate plasma clearance versus urinary plasma clearance of 51Cr-EDTA in patients with cirrhosis with and without fluid retention

    DEFF Research Database (Denmark)

    Fuglsang, Stefan; Henriksen, Ulrik L; Hansen, Hanne Boskov

    2017-01-01

    In patients with fluid retention, the plasma clearance of (51) Cr-EDTA (Clexp obtained by multiexponential fit) may overestimate the glomerular filtration rate (GFR). The present study was undertaken to compare a gamma-variate plasma clearance (Clgv) with the urinary plasma clearance of (51) Cr......-EDTA (Clu ) in patients with cirrhosis with and without fluid retention. A total of 81 patients with cirrhosis (22 without fluid retention, 59 with ascites) received a quantitative intravenous injection of (51) Cr-EDTA followed by plasma and quantitative urinary samples for 5 h. Clgv was determined from...... the injected dose relative to the plasma concentration-time area, obtained by a gamma-variate iterative fit. Clexp and Clu were determined by standard technique. In patients without fluid retention, Clgv , Clexp and Clu were closely similar. The difference between Clgv and Clu (Clgv - Clu = ΔCl) was mean -0...

  16. Measurement of single kidney contrast media clearance by multiphasic spiral computed tomography: preliminary results

    International Nuclear Information System (INIS)

    Hackstein, N.; Puille, M.F.; Bak, Benjamin H.; Scharwat, Oliver; Rau, W.S.

    2001-01-01

    Objective. We present preliminary results of a new method (hereinafter called 'CT-clearance') to measure single kidney contrast media clearance by performing multiphasic helical CT of the kidneys. CT-clearance was calculated according to an extension of the Patlak-Plot. In contrast to prior investigators, who repeatedly measured a single slice, this method makes it possible to calculate single kidney clearance from at least three spiral CTs, utilizing the whole kidney volume. Methods. Spiral CT of the kidneys was performed unenhanced and about 30 and 100 s after administration of about 120 ml iopromide. Sum-density of the whole kidneys and aortic density was calculated from this data. Using this data, renal clearance of contrast media was calculated by CT-clearance in 29 patients. As reference, Serum-clearance was calculated in 24 patients by application of a modified one-exponential slope model. Information on the relative kidney function was gained by renal scintigraphy with Tc99m-MAG-3 or Tc99m-DMSA in 29 patients. Results. Linear regression analysis revealed a correlation coefficient of CT-clearance with Serum-clearance of r=0.78 with Cl (CT) [ml/min]=22.2+1.03 * Cl (serum), n=24. Linear regression of the relative kidney function (rkf) of the right kidney calculated by CT-clearance compared to scintigraphy results provided a correlation coefficient r=0.89 with rkf(CT)[%]=18.6+0.58 * rkf(scintigraphy), n=29. Conclusion. The obtained results of contrast media clearance measured by CT-clearance are in the physiological range of the parameter. Future studies should be performed to improve the methodology with the aim of higher accuracy. More specifically, better determination of the aortic density curve might improve the accuracy

  17. Lung clearance of {sup 99m} Tc- DTPA in systemic lupus erythematous

    Energy Technology Data Exchange (ETDEWEB)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Dept. de Medicina Interna; Cunha, R.D.; Marroni, B.J. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Servico de Medicina Nuclear]. E-mail: rxavier@hcpa.ufrgs.br

    2002-06-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  18. Comparison of arterial intimal clearances of LDL from diabetic and nondiabetic cholesterol-fed rabbits. Differences in intimal clearance explained by size differences

    International Nuclear Information System (INIS)

    Nordestgaard, B.G.; Zilversmit, D.B.

    1989-01-01

    Arterial intimal clearances of low density lipoproteins (LDL) from diabetic cholesterol-fed rabbits (D-LDL) and LDL from nondiabetic cholesterol-fed rabbits (N-LDL) were compared. In six experiments, D-LDL and N-LDL were isolated from a diabetic and a nondiabetic rabbit, were iodinated with 125I and 131I, respectively, were mixed, and were reinjected into the same two rabbits as well as into a normal rabbit. Fractional catabolic rates for D-LDL and N-LDL in normal rabbits were 0.065 and 0.074 h-1 (p less than 0.05), respectively. For five of the six pairs of LDL, the D-LDL was smaller than N-LDL as determined by gel filtration. The arterial permeability to N-LDL, when normalized for differences in arterial cholesterol content, did not appear to differ between diabetic and nondiabetic rabbits. The relative arterial intimal clearance (D-LDL/N-LDL) in arteries from diabetic and nondiabetic rabbits was inversely related to the relative molecular weight (D-LDL/N-LDL). For example, when the molecular weight of D-LDL was as low as 60% of that of N-LDL (i.e., the diameter of D-LDL was reduced 16%), the intimal clearance of D-LDL was 40% larger than that of N-LDL. When, on the other hand, molecular weights and diameters of the two LDL were similar, the intimal clearance was also quite similar. These results suggest that arterial intimal clearance of LDL from diabetic and nondiabetic cholesterol-fed rabbits is comparable unless the two types of LDL have a different size

  19. Clearance of the cervical spine in clinically unevaluable trauma patients.

    Science.gov (United States)

    Halpern, Casey H; Milby, Andrew H; Guo, Wensheng; Schuster, James M; Gracias, Vicente H; Stein, Sherman C

    2010-08-15

    Meta-analytic costeffectiveness analysis. Our goal was to compare the results of different management strategies for trauma patients in whom the cervical spine was not clinically evaluable due to impaired consciousness, endotracheal intubation, or painful distracting injuries. We performed a structured literature review related to cervical spine trauma, radiographic clearance techniques (plain radiography, flexion/extension, CT, and MRI), and complications associated with semirigid collar use. Meta-analytic techniques were used to pool data from multiple sources to calculate pooled mean estimates of sensitivities and specificities of imaging techniques for cervical spinal clearance, rates of complications from various clearance strategies and from empirical use of semirigid collars. A decision analysis model was used to compare outcomes and costs among these strategies. Slightly more than 7.5% of patients who are clinically unevaluable have cervical spine injuries, and 42% of these injuries are associated with spinal instability. Sensitivity of plain radiography or fluoroscopy for spinal clearance was 57% (95% CI: 57%-60%). Sensitivities for CT and MRI alone were 83% (82%-84%) and 87% (84%-89%), respectively. Complications associated with collar use ranged from 1.3% (2 days) to 7.1% (10 days) but were usually minor and short-lived. Quadriplegia resulting from spinal instability missed by a clearance test had enormous impacts on longevity, quality of life, and costs. These impacts overshadowed the effects of prolonged collar application, even when the incidence of quadriplegia was extremely low. As currently used, neuroimaging studies for cervical spinal clearance in clinically unevaluable patients are not cost-effective compared with empirical immobilization in a semirigid collar.

  20. Clearance of slightly radioactive material from radiological control in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    1995-01-01

    Clearance from radiological control of slightly radioactive material arising from operation or decommissioning of nuclear installations has been practiced in Germany for nearly two decades. Meanwhile, for the clearance of metal generally approved and applicable recommendations for clearance levels have been issued. For other materials like building waste, case-by-case decisions are made by the state licensing authorities. Efforts to implement consistent sets of clearance levels for all kinds of material are under way. As several decommissioning projects will soon generate large amounts of materials from dismantling, a solution needs to be reached soon. The legal framework in Germany governing the use of atomic energy consists of the Atomic Energy Act and several ordinances. Rules and guidelines including the recommendations of the German Commission for Radiation Protection (SSK) exist on a lower level and are not legally binding. Several generic studies for the derivation of clearance levels for metals and building debris with alpha, beta, and gamma contamination have been performed on behalf of the Federal Ministry for Environment, Nature Conservation and Nuclear Safety, which oriented themselves on an individual dose of 10 microSv/a in agreement with IAEA recommendations. Stochastic models have been used for establishing the connection between specific activity of the material to be released and the resulting individual doses, with significant advantages over deterministic scenarios. In the future, for new SSK recommendations or an ordinance on clearance, the increase of masses from demolition of installations, higher recycling rates in the conventional sector and harmonization with international regulations and standards have to be taken into account

  1. Mucociliary clearance, airway inflammation and nasal symptoms in urban motorcyclists

    Directory of Open Access Journals (Sweden)

    Tereza C.S. Brant

    2014-01-01

    Full Text Available OBJECTIVES: There is evidence that outdoor workers exposed to high levels of air pollution exhibit airway inflammation and increased airway symptoms. We hypothesized that these workers would experience increased airway symptoms and decreased nasal mucociliary clearance associated with their exposure to air pollution. METHODS: In total, 25 non-smoking commercial motorcyclists, aged 18-44 years, were included in this study. These drivers work 8-12 hours per day, 5 days per week, driving on urban streets. Nasal mucociliary clearance was measured by the saccharine transit test; airway acidification was measured by assessing the pH of exhaled breath condensate; and airway symptoms were measured by the Sino-nasal Outcome Test-20 questionnaire. To assess personal air pollution exposure, the subjects used a passive-diffusion nitrogen dioxide (NO2 concentration-monitoring system during the 14 days before each assessment. The associations between NO2 and the airway outcomes were analyzed using the Mann-Whitney test and the Chi-Square test. Clinicaltrials.gov: NCT01976039. RESULTS: Compared with clearance in healthy adult males, mucociliary clearance was decreased in 32% of the motorcyclists. Additionally, 64% of the motorcyclists had airway acidification and 92% experienced airway symptoms. The median personal NO2 exposure level was 75 mg/m3 for these subjects and a significant association was observed between NO2 and impaired mucociliary clearance (p = 0.036. CONCLUSION: Non-smoking commercial motorcyclists exhibit increased airway symptoms and airway acidification as well as decreased nasal mucociliary clearance, all of which are significantly associated with the amount of exposure to air pollution.

  2. HBsAg-redirected T cells exhibit antiviral activity in HBV-infected human liver chimeric mice.

    Science.gov (United States)

    Kruse, Robert L; Shum, Thomas; Tashiro, Haruko; Barzi, Mercedes; Yi, Zhongzhen; Whitten-Bauer, Christina; Legras, Xavier; Bissig-Choisat, Beatrice; Garaigorta, Urtzi; Gottschalk, Stephen; Bissig, Karl-Dimiter

    2018-04-06

    Chronic hepatitis B virus (HBV) infection remains incurable. Although HBsAg-specific chimeric antigen receptor (HBsAg-CAR) T cells have been generated, they have not been tested in animal models with authentic HBV infection. We generated a novel CAR targeting HBsAg and evaluated its ability to recognize HBV+ cell lines and HBsAg particles in vitro. In vivo, we tested whether human HBsAg-CAR T cells would have efficacy against HBV-infected hepatocytes in human liver chimeric mice. HBsAg-CAR T cells recognized HBV-positive cell lines and HBsAg particles in vitro as judged by cytokine production. However, HBsAg-CAR T cells did not kill HBV-positive cell lines in cytotoxicity assays. Adoptive transfer of HBsAg-CAR T cells into HBV-infected humanized mice resulted in accumulation within the liver and a significant decrease in plasma HBsAg and HBV-DNA levels compared with control mice. Notably, the fraction of HBV core-positive hepatocytes among total human hepatocytes was greatly reduced after HBsAg-CAR T cell treatment, pointing to noncytopathic viral clearance. In agreement, changes in surrogate human plasma albumin levels were not significantly different between treatment and control groups. HBsAg-CAR T cells have anti-HBV activity in an authentic preclinical HBV infection model. Our results warrant further preclinical exploration of HBsAg-CAR T cells as immunotherapy for HBV. Copyright © 2018 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  3. Clearance of building structures for conventional non-nuclear reuse

    International Nuclear Information System (INIS)

    Buss, K.; Boehringer, S.

    1998-01-01

    At the example of a fuel assembly plant the strategy of control measurements on building surfaces, which shall be conventionally reused after their clearance, is regarded. Based on the given clearance levels the used measuring methods, especially with regard of possibly covered or intruded uranium contamination, are shown. The possibility of using the in-situ-γ-spectroscopy is discussed. (orig.) [de

  4. CO2 clearance by membrane lungs.

    Science.gov (United States)

    Sun, Liqun; Kaesler, Andreas; Fernando, Piyumindri; Thompson, Alex J; Toomasian, John M; Bartlett, Robert H

    2018-05-01

    Commercial membrane lungs are designed to transfer a specific amount of oxygen per unit of venous blood flow. Membrane lungs are much more efficient at removing CO 2 than adding oxygen, but the range of CO 2 transfer is rarely reported. Commercial membrane lungs were studied with the goal of evaluating CO 2 removal capacity. CO 2 removal was measured in 4 commercial membrane lungs under standardized conditions. CO 2 clearance can be greater than 4 times that of oxygen at a given blood flow when the gas to blood flow ratio is elevated to 4:1 or 8:1. The CO 2 clearance was less dependent on surface area and configuration than oxygen transfer. Any ECMO system can be used for selective CO 2 removal.

  5. Dynamic analysis of cross shaft type universal joint with clearance

    International Nuclear Information System (INIS)

    Lu, Jian Wei; Wang, Gong Cheng; Chen, Hao; Vakakis, Alexander F.; Bergman, Lawrence A.

    2013-01-01

    Cross shaft type universal joint is widely used in ground vehicles to transfer torque between two intersecting axes, and its transmission feature can make a great contribution to NVH performance of the vehicle. We looked at the assembling clearance at cross shaft neck, and presented a dynamic model of cross shaft type universal joint with clearance at cross shaft neck. Two-state model is applied to describe the contact force between the cross shaft and driving joint fork based on Hertz theorem, and lumped mass method is applied to build up the dynamic model of the universal joint. Based on this model, numerical analysis is carried out to discuss the transmission feature of the universal joint with clearance at cross shaft neck, and the influence of clearance on the dynamic behavior of the system is evaluated with numerical results based on time history, power spectrum, and phase portrait. The method and conclusions presented are helpful to improvement of the transmission feature of cross shaft type universal joint.

  6. Uncertainty analysis of 99mTc-HEPIDA liver clearance determination

    International Nuclear Information System (INIS)

    Surma, M. J.

    2005-01-01

    The aim of the study was to obtain information on the accuracy and precision of 99mT c-HEPIDA hepatic (Cl H p) and plasma (Cl P l) clearances and selection of an appropriate estimator of the measurement uncertainty of a single determination of these quantities. In a simulation (Monte Carlo) experiment, it was assumed that the recorded results of plasma and hepatic clearances, as obtained from 185 patients, provided authentic information about 99mT c-HEPIDA behaviour in the body over a wide range of the clearances studied. The time-course 99mT c-HEPIDA concentration in blood plasma has been described by means of biexponential function with parameter values derived for each patient. For each patient, using these data and urinary excretion data, there had been 5000 simulations performed; in each of the latter, the directly measured numbers have been substituted by simulated ones, obtained by means of varying the real ones, using random generated values. These reflected errors of plasma and radioactive standard pipetting (from 1 to 5%) and stochasticity of counting radioactive decay (1%). The time of blood sampling and urine voiding was also varied, assuming realistic uncertainty. The varied values were then used for computation of the simulated clearances. From the 5000 calculated clearances for each patient, mean-values were calculated, as well as mean standard errors, standard deviations and mean uncertainty of measurements using a widely accepted rule of partial error propagation, and, in addition, a modified rule of the latter. Accuracy of clearance (Cl P l, Cl H p, Cl U r) determination was assessed on the basis of comparison of mean values from simulations with those from directly recorded values. Precision was identified with standard deviation of each of the 5000 simulations. The uncertainty thus obtained was compared with results of calculated traditional and modified uncertainty. There was good agreement between standard deviation of the simulations with

  7. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    DEFF Research Database (Denmark)

    Vissing, J; Ohkuwa, T; Ploug, Thorkil

    1988-01-01

    with nonimmobilized control rats (red gastrocnemius 0.46 +/- 0.02 vs. 0.99 +/- 0.08 and soleus 1.10 +/- 0.30 vs. 3.97 +/- 0.54 ml.min-1.100 g-1, P less than 0.005). During running (18 m/min), glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always......In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise......-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[3H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared...

  8. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  9. Exclusion, exemption, clearance European Union approach

    International Nuclear Information System (INIS)

    Janssens, A.

    1997-01-01

    The presentation overviews the following issues: Euratom Basic Safety Standards; administrative requirements; radiation protection of the population. Scope of the Standards: natural radiation sources; exclusion. Exemption; Clearance; Import of radioactive scrap metal

  10. Impairment of paravascular clearance pathways in the aging brain.

    Science.gov (United States)

    Kress, Benjamin T; Iliff, Jeffrey J; Xia, Maosheng; Wang, Minghuan; Wei, Helen S; Zeppenfeld, Douglas; Xie, Lulu; Kang, Hongyi; Xu, Qiwu; Liew, Jason A; Plog, Benjamin A; Ding, Fengfei; Deane, Rashid; Nedergaard, Maiken

    2014-12-01

    In the brain, protein waste removal is partly performed by paravascular pathways that facilitate convective exchange of water and soluble contents between cerebrospinal fluid (CSF) and interstitial fluid (ISF). Several lines of evidence suggest that bulk flow drainage via the glymphatic system is driven by cerebrovascular pulsation, and is dependent on astroglial water channels that line paravascular CSF pathways. The objective of this study was to evaluate whether the efficiency of CSF-ISF exchange and interstitial solute clearance is impaired in the aging brain. CSF-ISF exchange was evaluated by in vivo and ex vivo fluorescence microscopy and interstitial solute clearance was evaluated by radiotracer clearance assays in young (2-3 months), middle-aged (10-12 months), and old (18-20 months) wild-type mice. The relationship between age-related changes in the expression of the astrocytic water channel aquaporin-4 (AQP4) and changes in glymphatic pathway function was evaluated by immunofluorescence. Advancing age was associated with a dramatic decline in the efficiency of exchange between the subarachnoid CSF and the brain parenchyma. Relative to the young, clearance of intraparenchymally injected amyloid-β was impaired by 40% in the old mice. A 27% reduction in the vessel wall pulsatility of intracortical arterioles and widespread loss of perivascular AQP4 polarization along the penetrating arteries accompanied the decline in CSF-ISF exchange. We propose that impaired glymphatic clearance contributes to cognitive decline among the elderly and may represent a novel therapeutic target for the treatment of neurodegenerative diseases associated with accumulation of misfolded protein aggregates. © 2014 American Neurological Association.

  11. Nuclear security. DOE actions to improve the personnel clearance program

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Bannerman, Carl J.; Daniel, Beverly A.

    1988-11-01

    The status of the Department of Energy's (DOE) implementation of recommendations in our two reports on DOE's personnel security clearance program was determined. The recommendations were aimed at improving the timeliness, accuracy, and efficiency of personnel security clearance decisions. Specifically, the objective was to determine and report on steps DOE is taking to implement these recommendations. In summary, it was found that DOE has either initiated action or is studying ways to address all the recommendations, but none of the recommendations have been completely implemented. The effectiveness of the DOE actions will depend, in part, on the adequacy of its internal control system for overseeing and evaluating program operations. DOE's personnel security clearance program is intended to provide reasonable assurance that personnel with access to classified information and materials are trustworthy. The Department requests that the Office of Personnel Management or the Federal Bureau of Investigation collect personal data on each person who requires such access to do his or her job. Based on these background investigations, DOE officials authorize individuals whose personal histories indicate that they are trustworthy to have access to classified information, secured facilities, and controlled materials as needed to perform their jobs. DOE has five types of these authorizations or personnel security clearances and must update information on personnel holding each type at 5-year intervals to confirm their continuing reliability. The five types are based on the types of security interests to which the person needs access, e.g., persons needing nuclear weapons-related data must have a Q clearance, and persons with a top secret clearance can have access to national security data classified as top secret

  12. Hepatic macrophage complement receptor clearance function following injury.

    Science.gov (United States)

    Cuddy, B G; Loegering, D J; Blumenstock, F A; Shah, D M

    1986-03-01

    Previous work has demonstrated that in vivo hepatic macrophage complement receptor clearance function is depressed following thermal injury. The present study was carried out to determine if complement receptor function depression is associated with other states of depressed host defense. Hepatic complement receptor clearance function was determined from the hepatic uptake of rat erythrocytes coated with antierythrocyte IgM (EIgM) in rats. Receptor function was determined following cannulation of a carotid artery, laparotomy plus enterotomy, hemorrhagic shock, trauma, thermal injury, acute bacteremia, acute endotoxemia, and injection of erythrocyte stroma, gelatinized lipid emulsion, or colloidal carbon. Hepatic uptake of EIgM was depressed following each of these experimental interventions except arterial cannulation. This effect was shown not to be due to a decrease in hepatic blood flow or depletion of complement and was therefore due to a depression in hepatic macrophage complement receptor clearance function. Thus, impairment of hepatic macrophage complement receptor function is associated with several states of depressed host defense.

  13. Clearance potential of ITER vacuum vessel activated materials

    International Nuclear Information System (INIS)

    Cepraga, D.G.; Cambi, G.; Frisoni, M.

    2002-01-01

    To demonstrate fusion's environmental attractiveness over the entire life cycle, a waste analysis is mandatory. The clearance is recommended by IAEA for releasing activated solid materials from regulatory control and for waste management policy. The paper focuses on the approach used to support waste analyses for ITER Generic Site Safety Report. The Material Unconditional Clearance Index of all the materials/zones on the equatorial mid-plane of ITER machine have been evaluated, based on IAEA-TECDOC-855. The Bonami-Nitawl-XSDNRPM sequence of the Scale-4.4a code system (using Vitenea-J library) has been firstly used for radiation transport analyses. Then the Anita-2000 code package is used for the activation calculation. The paper presents also, as an example, an application of the clearance indexes estimation for the ITER vacuum vessel materials. The results of the Anita-2000 have been compared with those obtained using the Fispact-99 activation code. (author)

  14. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  15. Clearance from the anterior chamber of RBCs from human diabetics

    International Nuclear Information System (INIS)

    Williams, G.A.; Hatchell, D.L.; Collier, B.D.; Knobel, J.

    1984-01-01

    Erythrocytes from diabetic patients manifest decreased deformability and increased adherence. These abnormal membrane properties may diminish the ability of erythrocytes (RBCs) from diabetics to undergo deformation in passage through the trabecular meshwork. Using sodium chromate Cr 51-labeled RBCs from type I diabetic patients with proliferative retinopathy and normal control subjects, we studied RBC clearance from the rabbit anterior chamber. The mean time for 50% clearance (T50) of RBCs from diabetics (76 hours) was significantly longer than that for RBCs from normal subjects (19.5 hours). In this model, RBCs from diabetics have a slower clearance from the anterior chamber than do RBCs from normal subjects

  16. Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance

    Science.gov (United States)

    Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.

    2002-01-01

    This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.

  17. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi

    1970-01-01

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ( 198 Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  18. Exaggerated natriuresis and lithium clearance in spontaneously hypertensive rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Kanters, J K; Leyssac, P P

    1988-01-01

    Since hypertension is associated with changes in the handling of various cations (including sodium and lithium) across the cell membrane, the present study investigated the validity of the lithium clearance method in hypertension by comparing two measures of proximal reabsorption. Thus, fractional...... lithium excretion and transit time (TT)-occlusion time (OT; e-TT/T) were determined successively in the same spontaneously hypertensive rat (SHR, Okamoto strain). The rats were examined both before and after an acute saline load. The results show that the lithium clearance method can be used...... for the determination of proximal reabsorption in SHR. Utilizing the lithium clearance method, the changes in renal sodium handling underlying the exaggerated natriuresis were investigated in unanaesthetized catheterized rats. It was found that the exaggerated natriuresis was associated with an increased output from...

  19. Kinematics Simulation Analysis of Packaging Robot with Joint Clearance

    Science.gov (United States)

    Zhang, Y. W.; Meng, W. J.; Wang, L. Q.; Cui, G. H.

    2018-03-01

    Considering the influence of joint clearance on the motion error, repeated positioning accuracy and overall position of the machine, this paper presents simulation analysis of a packaging robot — 2 degrees of freedom(DOF) planar parallel robot based on the characteristics of high precision and fast speed of packaging equipment. The motion constraint equation of the mechanism is established, and the analysis and simulation of the motion error are carried out in the case of turning the revolute clearance. The simulation results show that the size of the joint clearance will affect the movement accuracy and packaging efficiency of the packaging robot. The analysis provides a reference point of view for the packaging equipment design and selection criteria and has a great significance on the packaging industry automation.

  20. Numerical study on tip clearance effect on performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Shin Kyoung

    2003-01-01

    Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASCflow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected performance equally, while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully

  1. Plasma Creatinine Clearance in the Dog

    Science.gov (United States)

    Frazier, Loy W.

    1977-01-01

    Lists materials and methods for an experiment that demonstrates the concept of glomerular filtration rate (GFR) using anesthesized dogs. In the dog, GFR is equivalent to the renal plasma clearance of exogenous creatinine. (CS)

  2. Renal clearance of /sup 99m/Tc-methylene-diphosphonate in human beings

    Energy Technology Data Exchange (ETDEWEB)

    Vattimo, A.

    1987-12-01

    The renal clearance of /sup 99m/Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of /sup 51/Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the /sup 99m/Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion.

  3. Frequency and factors effecting non clearance of lower pole renal stones

    International Nuclear Information System (INIS)

    Ullah, A.; Zubair, M.; Khan, N.; Malik, A.

    2015-01-01

    Renal stone disease is a major health hazard in Pakistan and extra-corporeal shockwave lithotripsy is one of comprehensive method used to treat these stones. The aim of this study is to determine the frequency of factors affecting the non-clearance of stone fragments of lower pole renal stone after extra corporeal shockwave lithotripsy. The study was done with the objective to determine the frequency the spatial anatomical factors which can influence the non-clearance of lower pole stone fragments after ESWL. Methods: One and nineteen (119) patients with lower pole renal stone less than 10 mm were subjected to maximum 3 sessions of extracorporeal shock wave lithotripsy. KUB radiographs, ultrasonography and intravenous urography were used as investigative tools for lower pole renal calyceal anatomy. X ray KUB and ultrasound were done after a week for clearance. Data was analysed with the help of SPSS version 10.0 and presented in the forms of tables and graphs. Results: There were 77 (64.71%) males and 42 (35.29%) females. Infundibulo-pelvic angle (IPA)>40 degree was present in 93 (78.15%), Infundibular length (IL) <22 mm in 107 (89.92%) and Infundibular width (IW) >4 mm was present in 100 (84.03%) patients. The frequency of stone non clearance was noted in 31 (26.05%). Infundibulo-pelvic angle (IPA)>40 degree (p=0.000), Infundibular length (IL)<22 mm (p=0.001) and Infundibular width (IW)>4 mm (p=0.046) were significant variables affecting stone clearance. Conclusion: The frequency of non-clearance of lower calyx of kidney stone is 26.05%. The clearance of fragments of the lower calyx kidney stones is affected by three spatial anatomical factors, i.e., Infundibulopelvic angle, Infundibular width and infundibular length. (author)

  4. Turbulent Heat Transfer of a Finned Plate in a Duct as Tip Clearance Changes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae-Kyun; Chung, Bum-Jin [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    Fins are employed to enhance the cooling performance of a system. There are a number of studies relevant to geometry of fins. Meanwhile, the studies relevant to tip clearance, have not performed enough, which is the distance between the tips of the fins and the wall. We investigated the optimal tip clearance, which maximizes the heat transfers by experimental and numerical analyses with wider range of Re{sub Dh} than the previous studies. Turbulent heat transfers of a finned plate were measured. For an extended range of tip clearance and Re{sub Dh} than other studies. A joint experimental and numerical analyses was performed to measure heat transfers. Mass transfer experiments using electroplating system was used and FLUENT 6.3.26 was used for the calculation. For the narrow tip clearances below 5 mm, were investigated by numerical method only. The bypass flow to the tip clearance region contributes to heat transfer area at the tip clearance region and does not contributes that of the fin region. Thus, the optimal tip clearance was founded and it exists vicinity of 0.2 mm.

  5. Novel sensors to enable closed-loop active clearance control in gas turbine engines

    Science.gov (United States)

    Geisheimer, Jonathan; Holst, Tom

    2014-06-01

    Active clearance control within the turbine section of gas turbine engines presents and opportunity within aerospace and industrial applications to improve operating efficiencies and the life of downstream components. Open loop clearance control is currently employed during the development of all new large core aerospace engines; however, the ability to measure the gap between the blades and the case and close down the clearance further presents as opportunity to gain even greater efficiencies. The turbine area is one of the harshest environments for long term placement of a sensor in addition to the extreme accuracy requirements required to enable closed loop clearance control. This paper gives an overview of the challenges of clearance measurements within the turbine as well as discusses the latest developments of a microwave sensor designed for this application.

  6. Does sleep disturbance affect the amyloid clearance mechanisms in Alzheimer's disease?

    Science.gov (United States)

    Yulug, Burak; Hanoglu, Lutfu; Kilic, Ertugrul

    2017-10-01

    Sleep is an important factor that plays a key role in Alzheimer's disease pathogenesis. However, it is still unclear whether poor-quality sleep may overlap with sleep disturbances in the underlying dysfunctional mechanisms of amyloid beta (Aβ) clearance metabolism. Here, we aimed to evaluate the current evidence on the role of sleep deprivation in Aβ clearance metabolism. To that end, we discuss possible mechanisms underlying the bidirectional interaction between the sleep deprivation and Aβ clearance pathways. © 2017 The Authors. Psychiatry and Clinical Neurosciences © 2017 Japanese Society of Psychiatry and Neurology.

  7. The microbiota mediates pathogen clearance from the gut lumen after non-typhoidal Salmonella diarrhea.

    Directory of Open Access Journals (Sweden)

    Kathrin Endt

    Full Text Available Many enteropathogenic bacteria target the mammalian gut. The mechanisms protecting the host from infection are poorly understood. We have studied the protective functions of secretory antibodies (sIgA and the microbiota, using a mouse model for S. typhimurium diarrhea. This pathogen is a common cause of diarrhea in humans world-wide. S. typhimurium (S. tm(att, sseD causes a self-limiting gut infection in streptomycin-treated mice. After 40 days, all animals had overcome the disease, developed a sIgA response, and most had cleared the pathogen from the gut lumen. sIgA limited pathogen access to the mucosal surface and protected from gut inflammation in challenge infections. This protection was O-antigen specific, as demonstrated with pathogens lacking the S. typhimurium O-antigen (wbaP, S. enteritidis and sIgA-deficient mice (TCRβ(-/-δ(-/-, J(H (-/-, IgA(-/-, pIgR(-/-. Surprisingly, sIgA-deficiency did not affect the kinetics of pathogen clearance from the gut lumen. Instead, this was mediated by the microbiota. This was confirmed using 'L-mice' which harbor a low complexity gut flora, lack colonization resistance and develop a normal sIgA response, but fail to clear S. tm(att from the gut lumen. In these mice, pathogen clearance was achieved by transferring a normal complex microbiota. Thus, besides colonization resistance ( = pathogen blockage by an intact microbiota, the microbiota mediates a second, novel protective function, i.e. pathogen clearance. Here, the normal microbiota re-grows from a state of depletion and disturbed composition and gradually clears even very high pathogen loads from the gut lumen, a site inaccessible to most "classical" immune effector mechanisms. In conclusion, sIgA and microbiota serve complementary protective functions. The microbiota confers colonization resistance and mediates pathogen clearance in primary infections, while sIgA protects from disease if the host re-encounters the same pathogen. This has

  8. Predictive factors of lower calyceal stone clearance after Extracorporeal Shockwave Lithotripsy (ESWL): a focus on the infundibulopelvic anatomy.

    Science.gov (United States)

    Ghoneim, Islam A; Ziada, Ali M; Elkatib, Seif Eldin

    2005-08-01

    Controversy exists as to whether ESWL is suitable for lower pole renal stones, given the dependent position of the lower calyces. This study aims to test the effect of lower pole anatomy, namely lower polar infundibulo-pelvic angle, infundibular length and width, on clearance of fragments after ESWL. We conducted a retrospective study of 205 renal units with single lower pole stones of not more than 25 mm in their greatest diameter that were treated by ESWL alone. Exclusion criteria included multiple stones, patients requiring stenting or percutaneous drainage for various reasons. Pretreatment IVU was used to measure lower polar dimensions. Post treatment ultrasonography and KUB were used to assess clearance of fragments. The right kidney was involved in 68% and the left in 42% of cases. Average number of sessions was 1.6 with an average 3277 shockwaves per session. 134 patients (65.3%) required one session, 41 requiring 2 sessions (20%), 18 requiring 3 sessions (8.7%), 6 requiring 4 sessions (2.9%) and 8 requiring 5 sessions (3.9%). Complete clearance was attained in 141 cases, while 64 cases had residual fragments, 20 were asymptomatic and required no further management. The lower pole infundibulo-pelvic angle (LIP-A) was the most significant factor in clearance (p value 0.00001). Infundibular length (IL) was also statistically significant (p value 0.039). Lower pole anatomy has a significant impact on ESWL results. LIP-A not less than 70 degrees and an infundibular length of < 50 mm is preferable to achieve favorable outcome.

  9. 76 FR 59379 - Proposed Information Collection; Comment Request; Generic Clearance for Research in Development...

    Science.gov (United States)

    2011-09-26

    ...-XXXX. Type of Review: Generic Clearance Request. Title: Generic Clearance for Research in Development... information collected through qualitative evaluation methods will inform the disclosure form's design and... Proposed Information Collection; Comment Request; Generic Clearance for Research in Development of...

  10. A novel technique of contrast-enhanced optical coherence tomography imaging in evaluation of clearance of lipids in human tears.

    Science.gov (United States)

    Napoli, Pietro Emanuele; Coronella, Franco; Satta, Giovanni Maria; Fossarello, Maurizio

    2014-01-01

    The aim of this work was to gather preliminary data in different conditions of healthy eyes, aqueous tear deficient dry eyes, obstructive meibomian gland disease (MGD) and non-obvious obstructive MGD (NOMGD) individuals, using a new, contrast-enhanced optical coherence tomography (OCT) imaging method to evaluate the clearance of lipids in human tears. Eighty-two adult patients presenting with complaints of ocular irritation were studied for abnormalities of the ocular surface and classified as healthy (n = 21), aqueous tear deficient dry eyes (n = 20), obstructive MGD (n = 15) and NOMGD (n = 26) individuals. A lipid-based tracer, containing an oil-in-water emulsion, was used to obtain an enhanced OCT imaging of the lower tear meniscus. After instillation, a dramatic initial increase of reflectivity of the lower tear meniscus was detected by OCT, followed by a decay back to baseline values over time. Based on this finding, the clearance of lipids was measured in real-time by Fourier-domain anterior segment OCT. The differences in the clearance of lipids among the four groups as well as the correlations between symptom questionnaire score, standardized visual scale test, fluorescein break-up time, ocular surface fluorescein staining score, Schirmer I test scores were found to be statistically significant. The individual areas under the curve of the clearance of lipids calculated by the receiver operating characteristic curve technique ranged from 0.66 to 0.98, suggesting reliable sensitivity and specificity of lipid-enhanced OCT imaging. This new technique of contrast-enhanced OCT imaging of the tear film following lipid-based tracer instillation provides a measure of the clearance of lipids. The quantitative values found are in agreement with other methods of evaluation of the lacrimal system. An improvement of the clinician's ability in the diagnosis and understanding of abnormalities of the ocular surface may be achieved by this simple approach.

  11. A comparison of analytic procedures for measurement of fractional dextran clearances

    NARCIS (Netherlands)

    Hemmelder, MH; de Jong, PE; de Zeeuw, D

    Fractional dextran clearances have been extensively used to study glomerular size selectivity. We report on an analysis of different laboratory procedures involved in measuring fractional dextran clearances. The deproteinization of plasma samples by 20% trichloroacetic acid (TCA) revealed a protein

  12. Spontaneous Clearance of Hepatitis C after Liver and Renal Transplantation

    Directory of Open Access Journals (Sweden)

    CH Dale

    2009-01-01

    Full Text Available Spontaneous clearance of hepatitis C virus (HCV is rare in immunocompromised patients, such as those who have undergone organ transplantation. It has been recognized that patients receiving liver transplantation for HCV-related disease have decreased graft and patient survival compared with those transplanted for other etiologies. There is a growing trend toward treating HCV recurrence aggressively after liver transplantation. For other organ transplant recipients with concurrent HCV, treatment is not often an option, given the high rates of graft rejection and loss secondary to interferon and its immunomodulatory effects. Although spontaneous clearance of HCV has been reported in recipients of solitary liver and renal transplants, a common factor arising in these cases has been previous exposure to interferon. To date, no reports of spontaneous clearance of HCV RNA have been reported in a multiorgan transplant recipient. A case of spontaneous clearance of HCV RNA in an immunocompromised patient, within five months of simultaneous liver and kidney retransplantation is described. Importantly, this patient had no previous exposure to interferon.

  13. Derivation methods for clearance levels applied to reactors

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Seki, Takeo

    2001-01-01

    In order to support the discussion by the Nuclear Safety Commission, JAERI derived the unconditional clearance levels for concrete and metal arising from the operation and dismantling of nuclear reactors. The clearance levels of 20 radionuclides were derived from 10 μSv/y of individual doses by deterministic approach. In this approach, calculation models were established to assess individual doses resulting from 73 exposure pathways related to disposal and recycle/reuse, and realistic parameter values were selected considering Japanese natural and social conditions. The appropriateness of selected parameter values was confirmed by stochastic analyses. (author)

  14. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  15. CVVHD treatment with CARPEDIEM: small solute clearance at different blood and dialysate flows with three different surface area filter configurations.

    Science.gov (United States)

    Lorenzin, Anna; Garzotto, Francesco; Alghisi, Alberta; Neri, Mauro; Galeano, Dario; Aresu, Stefania; Pani, Antonello; Vidal, Enrico; Ricci, Zaccaroa; Murer, Luisa; Goldstein, Stuart L; Ronco, Claudio

    2016-10-01

    The CARdiorenal PEDIatric EMergency (CARPEDIEM) machine was originally designed to perform only continuous venovenous hemofiltration (CVVH) in neonatal and pediatric patients. In some cases, adequate convective clearance may not be reached because of a limited blood flow. In such conditions, the application of diffusive clearance [continuous venovenous hemodialysis (CVVHD)] would help optimize blood purification. In this study, the CARPEDIEM™ machine was modified to enable the circulation of dialysis through the filter allowing testing of the performance of CARPEDIEM™ machine in CVVHD. Three different polyethersulfone hemodialyzers (surface area = 0.1 m(2), 0.2 m(2), and 0.35 m(2), respectively) were tested in vitro with a scheduled combination of plasma flow rates (Qp = 10-20-30 ml/min) and dialysis fluid flow rate (Qd = 5-10-15 ml/min). Three sessions were performed in co-current and one in counter-current configuration (as control) for each filter size. Clearance was measured from the blood and dialysate sides and results with mass balance error greater than 5 % were discarded. Urea and creatinine clearances for each plasma/dialysate combination are reported: clearance increase progressively for every filter proportionally to plasma flow rates. Similarly, clearances increase progressively with dialysate flow rates at a given plasma flow. The clearance curve tends to present a steep increase for small increases in plasma flow in the range below 10 ml/min, while the curve tends to plateau for values averaging 30 ml/min. As expected, the plateau is reached earlier with the smaller filter showing the effect of membrane surface-area limitation. At every plasma flow, the effect of dialysate flow increase is evident and well defined, showing that saturation of effluent was not achieved completely in any of the experimental conditions explored. No differences (p > 0.05 for all values) were obtained in experiments using whole blood instead of

  16. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1970-09-15

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ({sup 198}Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  17. Clearance of labelled creatinine

    International Nuclear Information System (INIS)

    Eberstadt, P.; Liverant, J.

    1982-01-01

    Creatinine, extensively used in clinical work to evaluate glomerular filtration rate (G.F.R.) has caused controversy. Using simultaneously on dogs a gamma emitting agent measuring G.F.R., creatinine clearance proved to be higher. Aided by quantitative determinations and compartmental analysis fortunately the respective dilution spaces can be calculated. In the majority of these animals creatinine spaces are larger but in some equal to the ones of inulin

  18. Estudo da soroprevalência do AgHBs em gestantes da 15ª Regional de Saúde e da imunoprofilaxia para os recém-nascidos das gestantes AgHBs positivo = Study into the HBsAg seroprevalence in pregnant women from the 15th Health Regional and the immunoprophylaxia on the newborns of these HBsAg-positive women

    Directory of Open Access Journals (Sweden)

    Sonia Kaori Miyamoto

    2008-01-01

    Full Text Available Determinar a prevalência do AgHBs nas gestantes da 15ª Regional de Saúde (15ª R.S. atendidas no Laboratório de Ensino e Pesquisa em Análises Clínicas (Lepac, Universidade Estadual de Maringá, e verificar se foi solicitada a imunoprofilaxia para hepatite B aos recém-natos das gestantes AgHBs positivo, no período de janeiro de 1998 a dezembro de 2002. A pesquisa do AgHBs foi realizada pela técnica imunoenzimática IMxHBsAg e Axsym HBsAg (Laboratório Abbott. As solicitações de imunobiológicos especiais para a imunoprofilaxia da hepatite B ao CRIE foram obtidas na Seção de Epidemiologia da 15ª R.S. Foram analisadas 12.274 gestantes e a prevalência do AgHBs foide 1,0%. Dentre as 125 gestantes AgHBs positivo, foram solicitadas imunoprofilaxia para 32 (25,6% recém-nascidos. Ainda que a prevalência encontrada indique ser esta uma área de baixa endemicidade, os resultados reafirmam a importância da realização do diagnóstico da hepatite B no atendimento pré-natal, para adoção da imunoprofilaxia no recém-nascido.To determine HBsAg prevalence among pregnant women from the 15th Health Regional assisted in the Laboratório de Ensino e Pesquisa em Análises Clínicas (Lepac, Universidade Estadual de Maringá, and verify whether immunoprophylaxis with vaccine and immunoglobulin was requested for the newborns of HBsAg-positive women during the period from January 1998 to December 2002. The research about HBsAg was conducted using the immunoenzymatic IMxHBsAg (Abbot Lab and Axsym HBsAg (Abbot Lab techniques. The requests to the CRIE for specialimmunobiologic agents for Hepatitis B immunoprophylaxis were obtained in the Department of Epidemiology from the 15th Health Regional. The analysis includes 12,274 pregnant women, and the HBsAg prevalence was 1.0%. Among 125 HBsAg positive pregnant women, immunoprophylaxis was requested for 32 (25.6% newborns. Although the prevalence detected demonstrates this to be a low endemic area, the

  19. Relationship of end-expiratory pressure, lung volume, and /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Cooper, J.A.; van der Zee, H.; Line, B.R.; Malik, A.B.

    1987-01-01

    We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH 2 O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH 2 O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH 2 O PEEP. At 2.5 cmH 2 O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH 2 O (P less than 0.05). Between 15 and 20 cmH 2 O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized /sup 99m/Tc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation

  20. Foot clearance and variability in mono- and multifocal intraocular lens users during stair navigation.

    Science.gov (United States)

    Renz, Erik; Hackney, Madeleine; Hall, Courtney

    2016-01-01

    Intraocular lenses (IOLs) provide distance and near refraction and are becoming the standard for cataract surgery. Multifocal glasses increase variability of toe clearance in older adults navigating stairs and increase fall risk; however, little is known about the biomechanics of stair navigation in individuals with multifocal IOLs. This study compared clearance while ascending and descending stairs in individuals with monofocal versus multifocal IOLs. Eight participants with multifocal IOLs (4 men, 4 women; mean age = 66.5 yr, standard deviation [SD] = 6.26) and fifteen male participants with monofocal IOLs (mean age = 69.9 yr, SD = 6.9) underwent vision and mobility testing. Motion analysis recorded kinematic and custom software-calculated clearances in three-dimensional space. No significant differences were found between groups on minimum clearance or variability. Clearance differed for ascending versus descending stairs: the first step onto the stair had the greatest toe clearance during ascent, whereas the final step to the floor had the greatest heel clearance during descent. This preliminary study indicates that multifocal IOLs have similar biomechanic characteristics to monofocal IOLs. Given that step characteristics are related to fall risk, we can tentatively speculate that multifocal IOLs may carry no additional fall risk.

  1. A pre- and postoperative study of split isotope clearance in childhood

    International Nuclear Information System (INIS)

    Faerber, D.; Czempiel, H.; Muehle, P.; Schick, F.; Wenzl, H.; Technische Univ. Muenchen; Technische Univ. Muenchen

    1979-01-01

    In 1978 43 patients have been operated in the Department of Pediatric Surgery, Krankenhaus Muenchen-Schwabing, because of recurrent urinary-tract infections with ureterovesical reflux or obstructive urinary-tract diseases. In all patients a split whole body clearance-study with a method modified after the method of Muehle with 131 J-Hippuran was carried out pre- or postoperatively, respectively. In 78,5% of these cases the clearance-results were corresponding to the results of X-ray examination; 6 of the remaining patients had a worse clearance result and 3 had a better result than the X-ray findings would have suggested. (orig.) [de

  2. Scan Manifestation and Trace-Dose Radiogold Clearance Rates in Obstructive Jaundice

    International Nuclear Information System (INIS)

    Kim, Dong Jip; Bahk, Yong Whee; Shinn, Kyung Sub

    1969-01-01

    The present study has been undertaken to analyze scan manifestation in obstructive jaundice. Scan changes were correlated with the duration of jaundice. In addition, clearance rates of trace dose of colloidal radiogold were assessed in each case. The materials were consisted of 19 cases with surgically and/or histopathologically verified obstructive jaundice from various causes including common duct stone, empyema of the gall bladder and carcinoma of the pancreas head etc. Blood clearance rates of colloidal 198 Au were determined after the injection of 8 uCi by simple geometrical drawing of recorded strip charts. Scan was performed following additional injection of the sam radiogold. In 16 out of 19 cases, the scan rather typical 'arborifrom' mottlings around the porta hepatis. The intensity and appearance of such mottlings on the scan was related with the duration of jaundice and level of serum bilirubin and alkaline phosphatase. The blood clearance rates remained to be within normal range in 74 percent of the patients. In the remaining 26 percent, clearance rate ranged between 4.1 and 6 minutes. It is concluded that the association of 'arboriform' mottlings and normal or mildly delayed clearance rates in the patients with jaundice is characteristic of obstructive change in the biliary system.

  3. Scan Manifestation and Trace-Dose Radiogold Clearance Rates in Obstructive Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Jip; Bahk, Yong Whee; Shinn, Kyung Sub [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1969-09-15

    The present study has been undertaken to analyze scan manifestation in obstructive jaundice. Scan changes were correlated with the duration of jaundice. In addition, clearance rates of trace dose of colloidal radiogold were assessed in each case. The materials were consisted of 19 cases with surgically and/or histopathologically verified obstructive jaundice from various causes including common duct stone, empyema of the gall bladder and carcinoma of the pancreas head etc. Blood clearance rates of colloidal {sup 198}Au were determined after the injection of 8 uCi by simple geometrical drawing of recorded strip charts. Scan was performed following additional injection of the sam radiogold. In 16 out of 19 cases, the scan rather typical 'arborifrom' mottlings around the porta hepatis. The intensity and appearance of such mottlings on the scan was related with the duration of jaundice and level of serum bilirubin and alkaline phosphatase. The blood clearance rates remained to be within normal range in 74 percent of the patients. In the remaining 26 percent, clearance rate ranged between 4.1 and 6 minutes. It is concluded that the association of 'arboriform' mottlings and normal or mildly delayed clearance rates in the patients with jaundice is characteristic of obstructive change in the biliary system.

  4. Construction and immunological evaluation of truncated hepatitis B core particles carrying HBsAg amino acids 119–152 in the major immunodominant region (MIR)

    Energy Technology Data Exchange (ETDEWEB)

    Su, Qiudong; Yi, Yao [National Institute for Viral Disease Control and Prevention, China Center for Disease Control and Prevention, Changbai Road 155, Changping District, Beijing 102206 (China); Guo, Minzhuo [Beijing Entry-Exit Inspection and Quarantine Beureau, Tianshuiyuan Lane 6, Chaoyang District, Beijing 100026 (China); Qiu, Feng; Jia, Zhiyuan; Lu, Xuexin; Meng, Qingling [National Institute for Viral Disease Control and Prevention, China Center for Disease Control and Prevention, Changbai Road 155, Changping District, Beijing 102206 (China); Bi, Shengli, E-mail: shengli_bi@163.com [National Institute for Viral Disease Control and Prevention, China Center for Disease Control and Prevention, Changbai Road 155, Changping District, Beijing 102206 (China)

    2013-09-13

    Highlights: •The conformational HBV neutralization antigen domain was successfully displayed on the surface of truncated HBc particles. •Appropriate dialysis procedures to support the renaturing environment for the protein refolding. •Efficient purification procedures to obtain high purity and icosahedral particles of mosaic HBV antigen. •Strong immune responses not only including neutralization antibody response but also Th1 cell response were induced in mice. -- Abstract: Hepatitis B capsid protein expressed in Escherichia coli can reassemble into icosahedral particles, which could strongly enhance the immunogenicity of foreign epitopes, especially those inserted into its major immunodominant region. Herein, we inserted the entire ‘α’ antigenic determinant amino acids (aa) 119–152 of HBsAg into the truncated HBc (aa 1–144), between Asp{sup 78} and Pro{sup 79}. Prokaryotic expression showed that the mosaic HBc was mainly in the form of inclusion bodies. After denaturation with urea, it was dialyzed progressively for protein renaturation. We observed that before and after renaturation, mosaic HBc was antigenic as determined by HBsAg ELISA and a lot of viruslike particles were observed after renaturation. Thus, we further purified the mosaic viruslike particles by (NH{sub 4}){sub 2}SO{sub 4} precipitation, DEAE chromatography, and Sepharose 4FF chromatography. Negative staining electron microscopy demonstrated the morphology of the viruslike particles. Immunization of Balb/c mice with mosaic particles induced the production of anti-HBs antibody and Th1 cell immune response supported by ELISPOT and CD4/CD8 proportions assay. In conclusion, we constructed mosaic hepatitis core particles displaying the entire ‘α’ antigenic determinant on the surface and laid a foundation for researching therapeutic hepatits B vaccines.

  5. 20 CFR 653.501 - Requirements for accepting and processing clearance orders.

    Science.gov (United States)

    2010-04-01

    ... the job order. (i) No agricultural or food processing order shall be included in job bank listings... clearance any job order seeking workers to perform agricultural or food processing work before reviewing it... order seeking workers to perform agricultural or food processing work into intrastate clearance unless...

  6. 10 CFR 95.21 - Withdrawal of requests for facility security clearance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Withdrawal of requests for facility security clearance. 95.21 Section 95.21 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL SECURITY INFORMATION AND RESTRICTED DATA Physical Security § 95.21 Withdrawal of...

  7. Clearance of insoluble dust from the lower respiratory tract

    Energy Technology Data Exchange (ETDEWEB)

    Morrow, P E; Gibb, F R; Johnson, L

    1964-01-01

    Clearance of tagged heavy metal aerosols (Fe, Hg, Mn, Ba, and U) in female beagles by in vivo counting was assessed. Fecal excretion paralleled lower respiratory tract clearance of Fe. No Fe was found in blood, indicating its biological insolubility. Ultrafiltration tests (an indication of biological solubility) ranked the heavy metals as: Hg, Mn, Fe, and U in order of decreasing solubility. The solubility ratios were remarkably similar to the ratios of inverse biological half-times.

  8. Clearance Prediction Methodology Needs Fundamental Improvement: Trends Common to Rat and Human Hepatocytes/Microsomes and Implications for Experimental Methodology.

    Science.gov (United States)

    Wood, F L; Houston, J B; Hallifax, D

    2017-11-01

    Although prediction of clearance using hepatocytes and liver microsomes has long played a decisive role in drug discovery, it is widely acknowledged that reliably accurate prediction is not yet achievable despite the predominance of hepatically cleared drugs. Physiologically mechanistic methodology tends to underpredict clearance by several fold, and empirical correction of this bias is confounded by imprecision across drugs. Understanding the causes of prediction uncertainty has been slow, possibly reflecting poor resolution of variables associated with donor source and experimental methods, particularly for the human situation. It has been reported that among published human hepatocyte predictions there was a tendency for underprediction to increase with increasing in vivo intrinsic clearance, suggesting an inherent limitation using this particular system. This implied an artifactual rate limitation in vitro, although preparative effects on cell stability and performance were not yet resolved from assay design limitations. Here, to resolve these issues further, we present an up-to-date and comprehensive examination of predictions from published rat as well as human studies (where n = 128 and 101 hepatocytes and n = 71 and 83 microsomes, respectively) to assess system performance more independently. We report a clear trend of increasing underprediction with increasing in vivo intrinsic clearance, which is similar both between species and between in vitro systems. Hence, prior concerns arising specifically from human in vitro systems may be unfounded and the focus of investigation in the future should be to minimize the potential in vitro assay limitations common to whole cells and subcellular fractions. Copyright © 2017 by The American Society for Pharmacology and Experimental Therapeutics.

  9. Dependence of 'CT clearance' on dosage and time

    International Nuclear Information System (INIS)

    Kaltenborn, H.A.; Klose, K.J.; Dexheimer, C.; Steinijans, V.

    1989-01-01

    The contrast medium dose used in CT renal function analysis corresponds to about 1 ml/kg body weight at a measurement interval of 5 or 10 minutes. In the present study the dependence of 'CT clearance' on dosage and time was examined in 12 healthy subjects. The amount of clearance was directly proportional to the employed contrast medium dose and to the length of the measurement interval. On account of the superior signal-to-noise ratio, the higher dose (1 ml/kg body weight) will continue to be prefered in future. The measurement interval can be limited to 10 minutes. (orig.) [de

  10. Pulmonary epithelial clearance of 99mTc-DTPA after thrombin-induced pulmonary microembolism

    International Nuclear Information System (INIS)

    Cooper, J.A.; Feustel, P.J.; Line, B.R.; Malik, A.B.

    1986-01-01

    We investigated the effect of thrombin-induced pulmonary microembolism on the pulmonary clearance rate of aerosolized 99mTc diethylenetriamine pentaacetic acid (99mTc-DTPA) in awake, chronically prepared sheep. Chest activity was recorded after administration of a 0.44 micron aerosol of 99mTc-DTPA. Decay-corrected data were fit to an exponential and expressed as percent decrease per min (%/min). Sheep were given alpha-thrombin intravenously (80 U/kg for 10 min) 60 min after the aerosol administration. The clearance rate prior to alpha-thrombin was 0.35 +/- 0.05 %/min (mean +/- SEM). During alpha-thrombin administration, the clearance rate increased to 5.84 +/- 0.70 %/min (p less than 0.001 from baseline), but returned to 0.41 +/- 0.06 %/min within 30 min after the end of the thrombin infusion. The increased clearance rate during alpha-thrombin administration was not due to increased lung volume since alpha-thrombin did not change functional residual capacity. Moreover, the clearance rate was unchanged during gamma-thrombin administration, which does not induce coagulation, or during alpha-thrombin challenge in defibrinogenated animals. alpha-thrombin administration in neutrophil-depleted sheep caused a transient increase in DTPA clearance similar to that in control sheep, suggesting that the increase occurred independently of neutrophils. The results indicate that alpha-thrombin causes a large, transient increase in 99mTc-DTPA clearance, which may be the result of increased epithelial permeability. This response is dependent on the activation of intravascular coagulation

  11. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems

    Science.gov (United States)

    Tomassini, R.; Rossi, G.; Brouckaert, J.-F.

    2016-10-01

    A simultaneous blade tip timing (BTT) and blade tip clearance (BTC) measurement system enables the determination of turbomachinery blade vibrations and ensures the monitoring of the existing running gaps between the blade tip and the casing. This contactless instrumentation presents several advantages compared to the well-known telemetry system with strain gauges, at the cost of a more complex data processing procedure. The probes used can be optical, capacitive, eddy current as well as microwaves, everyone with its dedicated electronics and many existing different signal processing algorithms. Every company working in this field has developed its own processing method and sensor technology. Hence, repeating the same test with different instrumentations, the answer is often different. Moreover, rarely it is possible to achieve reliability for in-service measurements. Developments are focused on innovative instrumentations and a common standard. This paper focuses on the results achieved using a novel magnetoresistive sensor for simultaneous tip timing and tip clearance measurements. The sensor measurement principle is described. The sensitivity to gap variation is investigated. In terms of measurement of vibrations, experimental investigations were performed at the Air Force Institute of Technology (ITWL, Warsaw, Poland) in a real aeroengine and in the von Karman Institute (VKI) R2 compressor rig. The advantages and limitations of the magnetoresistive probe for turbomachinery testing are highlighted.

  12. Rapid Treponema pallidum clearance from blood and ulcer samples following single dose benzathine penicillin treatment of early syphilis.

    Science.gov (United States)

    Tipple, Craig; Jones, Rachael; McClure, Myra; Taylor, Graham

    2015-02-01

    Currently, the efficacy of syphilis treatment is measured with anti-lipid antibody tests. These can take months to indicate cure and, as a result, syphilis treatment trials require long periods of follow-up. The causative organism, Treponema pallidum (T. pallidum), is detectable in the infectious lesions of early syphilis using DNA amplification. Bacteraemia can likewise be identified, typically in more active disease. We hypothesise that bacterial clearance from blood and ulcers will predict early the standard serology-measured treatment response and have developed a qPCR assay that could monitor this clearance directly in patients with infectious syphilis. Patients with early syphilis were given an intramuscular dose of benzathine penicillin. To investigate the appropriate sampling timeframe samples of blood and ulcer exudate were collected intensively for T. pallidum DNA (tpp047 gene) and RNA (16S rRNA) quantification. Sampling ended when two consecutive PCRs were negative. Four males were recruited. The mean peak level of T. pallidum DNA was 1626 copies/ml whole blood and the mean clearance half-life was 5.7 hours (std. dev. 0.53). The mean peak of 16S rRNA was 8879 copies/ml whole blood with a clearance half-life of 3.9 hours (std. dev. 0.84). From an ulcer, pre-treatment, 67,400 T. pallidum DNA copies and 7.08 x 107 16S rRNA copies were detected per absorbance strip and the clearance half-lives were 3.2 and 4.1 hours, respectively. Overall, T. pallidum nucleic acids were not detected in any sample collected more than 56 hours (range 20-56) after treatment. All patients achieved serologic cure. In patients with active early syphilis, measuring T. pallidum levels in blood and ulcer exudate may be a useful measure of treatment success in therapeutic trials. These laboratory findings need confirmation on a larger scale and in patients receiving different therapies.

  13. Rapid Treponema pallidum clearance from blood and ulcer samples following single dose benzathine penicillin treatment of early syphilis.

    Directory of Open Access Journals (Sweden)

    Craig Tipple

    2015-02-01

    Full Text Available Currently, the efficacy of syphilis treatment is measured with anti-lipid antibody tests. These can take months to indicate cure and, as a result, syphilis treatment trials require long periods of follow-up. The causative organism, Treponema pallidum (T. pallidum, is detectable in the infectious lesions of early syphilis using DNA amplification. Bacteraemia can likewise be identified, typically in more active disease. We hypothesise that bacterial clearance from blood and ulcers will predict early the standard serology-measured treatment response and have developed a qPCR assay that could monitor this clearance directly in patients with infectious syphilis. Patients with early syphilis were given an intramuscular dose of benzathine penicillin. To investigate the appropriate sampling timeframe samples of blood and ulcer exudate were collected intensively for T. pallidum DNA (tpp047 gene and RNA (16S rRNA quantification. Sampling ended when two consecutive PCRs were negative. Four males were recruited. The mean peak level of T. pallidum DNA was 1626 copies/ml whole blood and the mean clearance half-life was 5.7 hours (std. dev. 0.53. The mean peak of 16S rRNA was 8879 copies/ml whole blood with a clearance half-life of 3.9 hours (std. dev. 0.84. From an ulcer, pre-treatment, 67,400 T. pallidum DNA copies and 7.08 x 107 16S rRNA copies were detected per absorbance strip and the clearance half-lives were 3.2 and 4.1 hours, respectively. Overall, T. pallidum nucleic acids were not detected in any sample collected more than 56 hours (range 20-56 after treatment. All patients achieved serologic cure. In patients with active early syphilis, measuring T. pallidum levels in blood and ulcer exudate may be a useful measure of treatment success in therapeutic trials. These laboratory findings need confirmation on a larger scale and in patients receiving different therapies.

  14. Numerical Investigation of Pressure Fluctuation Characteristics in a Centrifugal Pump with Variable Axial Clearance

    Directory of Open Access Journals (Sweden)

    Lei Cao

    2016-01-01

    Full Text Available Clearance flows in the sidewall gaps of centrifugal pumps are unsteady as well as main flows in the volute casing and impeller, which may cause vibration and noise, and the corresponding pressure fluctuations are related to the axial clearance size. In this paper, unsteady numerical simulations were conducted to predict the unsteady flows within the entire flow passage of a centrifugal pump operating in the design condition. Pressure fluctuation characteristics in the volute casing, impeller, and sidewall gaps were investigated with three axial clearance sizes. Results show that an axial clearance variation affects the pressure fluctuation characteristics in each flow domain by different degree. The greatest pressure fluctuation occurs at the blade pressure surface and is almost not influenced by the axial clearance variation which has a certainly effect on the pressure fluctuation characteristics around the tongue. The maximum pressure fluctuation amplitude in the sidewall gaps is larger than that in the volute casing, and different spectrum characteristics show up in the three models due to the interaction between the clearance flow and the main flow as well as the rotor-stator interaction. Therefore, clearance flow should be taken into consideration in the hydraulic design of centrifugal pumps.

  15. Glomerular filtration in kidney recipients measured by plasma clearance of 169Yb-DTPA

    International Nuclear Information System (INIS)

    Stribrna, J.; Oppelt, A.; Jirickova, E.; Janata, V.; Kocandrle, V.; Sup, I.; Woller, P.; Franke, W.G.

    1986-01-01

    Values of 169 Yb-DTPA clearance (C DTPA ) calculated after a single injection were compared in 26 recipients of kidneys with renal clearance of inulin (C in ), polyfructosan S (C pf ) and creatinine (C cr ). In 21 patients the examinations were made simultaneously, in 5 patients C DTPA was measured within a short interval after the examination of renal clearance. The mean C DTPA values did not significantly differ from C cr but were significantly higher (p in and C pf (by 33% on average). Investigation of changes in C DTPA as compared with C in and C pf showed no significant difference in glomerular filtration (GF). This was measured using inulin and polyfructosan. The results showed that the differing molecular weight of inulin and polyfructosan S had no detectable effect on the GF of kidney recipients. The plasma clearance of 169 Yb-DTPA similarly to C cr overestimates the GF measured by inulin and polyfructosan clearance. (author)

  16. A computer program for unilateral renal clearance calculation by a modified Oberhausen method

    International Nuclear Information System (INIS)

    Brueggemann, G.

    1980-01-01

    A FORTAN program is presented which, on the basis of data obtained with NUKLEOPAN M, calculates the glomerular filtration rate with sup(99m)Tc-DTPA, the unilateral effective renal plasma flow with 131 I-hippuran, and the parameters for describing the isotope rephrogram (ING) with 131 I-hippuran. The results are calculated fully automatically upon entry of the data, and the results are processed and printed out. The theoretical fundamentals of ING and whole-body clearance calculation are presented as well as the methods available for unilateral clearance calculation, and the FORTAN program is described in detail. The standard values of the method are documented, as well as a comparative gamma camera study of 48 patients in order to determine the accuracy of unilateral imaging with the NUKLEOPAN M instrument, a comparison of unilateral clearances by the Oberhausen and Taplin methods, and a comparison between 7/17' plasma clearance and whole-body clearance. Problems and findings of the method are discussed. (orig./MG) [de

  17. Clearance, a powerful tool in optimizing the volume of radioactive wastes

    International Nuclear Information System (INIS)

    Blommaert, W.; Teunckens, L.

    1997-01-01

    In the framework its activities in decommissioning nuclear installations, Belgoprocess applies the clearance practice in optimizing the volume of radioactive wastes. The applied clearance methodology is discussed with special emphasis to different types of materials and to the associated measurements. Four practical cases are elaborated, dealing with the decommissioning and decontamination of two small buildings up to green field conditions, the unconditional release of large quantities of slightly contaminated active carbon, the melting and clearance of stainless steel fuel racks and of aluminium heat exchangers. The attention is drawn on practical problems associated with sampling and measurement strategies, in relation to the proposed low limits for unconditional release. (author)

  18. A review and comparison of international exemption and clearance levels

    International Nuclear Information System (INIS)

    Cooper, J.R.; Mobbs, S.F.

    1997-01-01

    The publication of new European Basic Safety Standards by the European Commission and of new International Basic Safety Standards by the IAEA together with other international agencies, has led to increased interest in the application of the concepts of exemption and clearance. This paper discusses the derivation of radionuclide-specific exemption and clearance values for application in various areas of the regulation of radioactive materials. (author)

  19. Comparison of gas clearance and radioactive microspheres for pancreatic blood flow measurement

    International Nuclear Information System (INIS)

    DeMar, A.R.; Graham, L.S.; Lake, R.; Fink, A.S.

    1989-01-01

    Measurement of pancreatic blood flow (PBF) is technically demanding. Although radiolabeled microspheres are considered the gold standard for PBF assessment, they have practical limitations. In the current study, H 2 and xenon-133 gas clearance techniques were adapted to PBF measurement and compared to radiolabeled microsphere techniques. Simultaneous measurements of PBF were made using either hydrogen or xenon gas washout and radiolabeled microspheres. Measurements were made under basal, vasoconstricted (vasopressin 2U i.v. or nicotine 4 micrograms/kg/h) and stimulated (secretin 125 ng/kg/h or 2 U/kg i.v.) conditions (random order). Mean PBF was 26.9 +/- 5.3, 50.5 +/- 2.3 and 27.6 +/- 5.2 ml/min/100 g basally, 36.9 +/- 8.0, 90.1 +/- 18.9, and 81.7 +/- 14.5 ml/min/100 g in the stimulated state, and 24.2 +/- 7.8, 25.0 +/- 3.5, and 14.9 +/- 7.5 ml/min/100 g in the vasoconstricted state for hydrogen gas clearance, xenon gas clearance, and radiolabeled microspheres, respectively. The H 2 clearance technique resulted in tissue trauma, was complicated by frequent electrode displacement, and correlated poorly (r2 = 0.36, p greater than 0.05) with microsphere values. In contrast, xenon clearance measurement had no apparent effect on the pancreas and correlated well (r2 = 0.83, p less than 0.01) with microsphere data. We conclude that xenon clearance offers an attractive, validated alternative to radiolabeled microspheres for measuring pancreatic blood flow

  20. Long-term clearance from small airways in subjects with ciliary dysfunction

    Directory of Open Access Journals (Sweden)

    Hjelte Lena

    2006-05-01

    Full Text Available Abstract The objective of this study was to investigate if long-term clearance from small airways is dependent on normal ciliary function. Six young adults with primary ciliary dyskinesia (PCD inhaled 111 Indium labelled Teflon particles of 4.2 μm geometric and 6.2 μm aerodynamic diameter with an extremely slow inhalation flow, 0.05 L/s. The inhalation method deposits particles mainly in the small conducting airways. Lung retention was measured immediately after inhalation and at four occasions up to 21 days after inhalation. Results were compared with data from ten healthy controls. For additional comparison three of the PCD subjects also inhaled the test particles with normal inhalation flow, 0.5 L/s, providing a more central deposition. The lung retention at 24 h in % of lung deposition (Ret24 was higher (p 24 with slow inhalation flow was 73.9 ± 1.9 % compared to 68.9 ± 7.5 % with normal inhalation flow in the three PCD subjects exposed twice. During day 7–21 the three PCD subjects exposed twice cleared 9 % with normal flow, probably representing predominantly alveolar clearance, compared to 19 % with slow inhalation flow, probably representing mainly small airway clearance. This study shows that despite ciliary dysfunction, clearance continues in the small airways beyond 24 h. There are apparently additional clearance mechanisms present in the small airways.

  1. APPLICATION OF DSM IN OBSTACLE CLEARANCE SURVEYING OF AERODROME

    Directory of Open Access Journals (Sweden)

    X. Qiao

    2016-06-01

    Full Text Available Compared to the wide use of digital elevation model (DEM, digital surface model (DSM receives less attention because that it is composed by not only terrain surface, but also vegetations and man-made objects which are usually regarded as useless information. Nevertheless, these objects are useful for the identification of obstacles around an aerodrome. The primary objective of the study was to determine the applicability of DSM in obstacle clearance surveying of aerodrome. According to the requirements of obstacle clearance surveying at QT airport, aerial and satellite imagery were used to generate DSM, by means of photogrammetry, which was spatially analyzed with the hypothetical 3D obstacle limitation surfaces (OLS to identify the potential obstacles. Field surveying was then carried out to retrieve the accurate horizontal position and height of the obstacles. The results proved that the application of DSM could make considerable improvement in the efficiency of obstacle clearance surveying of aerodrome.

  2. Dysregulation of Nutrient Sensing and CLEARance in Presenilin Deficiency

    Directory of Open Access Journals (Sweden)

    Kavya Reddy

    2016-03-01

    Full Text Available Attenuated auto-lysosomal system has been associated with Alzheimer disease (AD, yet all underlying molecular mechanisms leading to this impairment are unknown. We show that the amino acid sensing of mechanistic target of rapamycin complex 1 (mTORC1 is dysregulated in cells deficient in presenilin, a protein associated with AD. In these cells, mTORC1 is constitutively tethered to lysosomal membranes, unresponsive to starvation, and inhibitory to TFEB-mediated clearance due to a reduction in Sestrin2 expression. Normalization of Sestrin2 levels through overexpression or elevation of nuclear calcium rescued mTORC1 tethering and initiated clearance. While CLEAR network attenuation in vivo results in buildup of amyloid, phospho-Tau, and neurodegeneration, presenilin-knockout fibroblasts and iPSC-derived AD human neurons fail to effectively initiate autophagy. These results propose an altered mechanism for nutrient sensing in presenilin deficiency and underline an importance of clearance pathways in the onset of AD.

  3. Effects of sustained exercise on pulmonary clearance of aerosolized 99mTc-DTPA

    International Nuclear Information System (INIS)

    Lorino, A.M.; Meignan, M.; Bouissou, P.; Atlan, G.

    1989-01-01

    The effects of intensive prolonged exercise on the pulmonary clearance rate of aerosolized 99m Tc-labeled diethylenetriaminepentaacetate ( 99m Tc-DTPA) and pulmonary mechanics were studied in seven healthy nonsmoking volunteers. 99m Tc-DTPA clearance and pulmonary mechanics (lung volumes and compliance) were assessed before and after 75 min of constant-load exercise performed on a treadmill, corresponding to 75% of maximal O 2 uptake. Because both clearance measurements were made in similar conditions of pulmonary blood flow, respiratory rate, and tidal volume, changes in clearance rate can be assumed to represent changes of alveolar epithelial permeability. After exercise, total, apical, and basal clearance were significantly increased (P less than 0.01, 0.05, and 0.05, respectively) and the increases in total clearance and tidal volume observed during exercise were significantly correlated (P less than 0.05). In contrast, no significant change was found in pulmonary mechanics. These results show that prolonged intensive exercise induces an increase in epithelial permeability, which appears to be related to the mechanical effects of sustained increased ventilation. Because no change was evidenced in pulmonary volumes or in lung elasticity, our results suggest that this increase may result from alteration of the intercellular tight junctions rather than from a surfactant deficiency

  4. Higher Midazolam Clearance in Obese Adolescents Compared with Morbidly Obese Adults

    NARCIS (Netherlands)

    Rongen, van A.; Brill, M.J.E.; Vaughns, J.D.; Välitalo, P.A.J.; Dongen, van E.P.A.; Ramshorst, van B.; Barrett, J.S.; Anker, van den J.N.; Knibbe, C.A.J.

    2017-01-01

    The clearance of cytochrome P450 (CYP) 3A substrates is reported to be reduced with lower age, inflammation and obesity. As it is unknown what the overall influence is of these factors in the case of obese adolescents vs. morbidly obese adults, we studied covariates influencing the clearance of the

  5. Characterization and Clearance of m/s Sigyn

    International Nuclear Information System (INIS)

    Jiselmark, Jonatan; Vreede, Patrick

    2016-01-01

    M/s Sigyn was a 2044 ton ship that transported contaminated material between 1982 and 2013. Most of the transports were with spent nuclear fuel between Swedish nuclear power plants and the Swedish fuel repository, Clab. In addition to spent fuel, m/s Sigyn also transported big contaminated components, from nuclear power plants in Europe, to Studsvik for analysis or decontamination and melting. She also transported components from Swedish nuclear power plants to final disposal of short lived waste, SFR. Even though all transported items have been cleaned, checked and wrapped with plastics, some activity ended up as contamination onboard. In December 2013 it was decided that m/s Sigyn was subject for decommissioning due to her age. This Paper describes the method in which the activity onboard m/s Sigyn was characterized and clearance levels were calculated. This method for radiological characterization and clearance has recently been developed in Sweden, the method is efficient in that it does not need a big pre characterization survey. Only the nuclide distribution and history of the object, is needed to start the final survey. In the future there will be further development of the method, making it possible to reduce the number of measurements even more. This will further optimize the method and reduce the cost for final surveys and clearance. (authors)

  6. A stochastic approach to the derivation of exemption and clearance levels

    International Nuclear Information System (INIS)

    Deckert, A.

    1997-01-01

    Deciding what clearance levels are appropriate for a particular waste stream inherently involves a number of uncertainties. Some of these uncertainties can be quantified using stochastic modeling techniques, which can aid the process of decision making. In this presentation the German approach to dealing with the uncertainties involved in setting clearance levels is addressed. (author)

  7. Modelling of Outer and Inner Film Oil Pressure for Floating Ring Bearing Clearance in Turbochargers

    International Nuclear Information System (INIS)

    Zhang Hao; Shi Zhanqun; Gu Fengshou; Ball, Andrew

    2011-01-01

    Floating ring bearing is widely used in turbochargers to undertake the extreme condition of high rotating speed and high operating temperature. It is also the most concerned by the designers and users alike due to its high failure rate and high maintenance cost. Any little clearance change may result in oil leakage, which in turn cause blue smoke or black smoke according to leakage types. However, there is no condition monitoring of this bearing because it is almost impossible to measure the clearance especially the inner clearance, in which the inner oil film directly bears the high speed rotation. In stead of measuring clearance directly, this paper has proposed a method that uses film pressure as a measure to monitor the bearing clearance and its variation. A non-linear mathematical model is developed by using Reynolds equations with non-linear oil film pressure. A full description of the outer and inner film is provided along both axial and radial directions. A numerical simulation is immediately carried out. Variable clearance changes are investigated using the mathematical model. Results show the relationship between clearance and film pressure.

  8. Comparison between total and renal plasma clearance of [51Cr]EDTA

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Roedbro, P.

    1976-01-01

    The total plasma (E 1 ) and renal plasma (E 2 ) clearances of [ 51 Cr]EDTA were measured simultaneously in 40 patients with a wide range of renal function. The regression equation was E 1 = 0.997E 2 + 4.1; the slope of the regression line was not significantly different from 1.00, and the intercept differed significantly from zero. The results suggest that [ 51 Cr]EDTA has a significant extrarenal clearance of approximately 4 ml/min, independent of renal function. The data are used to correct the total [ 51 Cr]EDTA plasma clearance, measured by a simplified method, to yield a rapid, accurate and precise measurement of glomerular filtration rate for routine clinical use. (Auth.)

  9. Traffic Incident Clearance Time and Arrival Time Prediction Based on Hazard Models

    Directory of Open Access Journals (Sweden)

    Yang beibei Ji

    2014-01-01

    Full Text Available Accurate prediction of incident duration is not only important information of Traffic Incident Management System, but also an effective input for travel time prediction. In this paper, the hazard based prediction models are developed for both incident clearance time and arrival time. The data are obtained from the Queensland Department of Transport and Main Roads’ STREAMS Incident Management System (SIMS for one year ending in November 2010. The best fitting distributions are drawn for both clearance and arrival time for 3 types of incident: crash, stationary vehicle, and hazard. The results show that Gamma, Log-logistic, and Weibull are the best fit for crash, stationary vehicle, and hazard incident, respectively. The obvious impact factors are given for crash clearance time and arrival time. The quantitative influences for crash and hazard incident are presented for both clearance and arrival. The model accuracy is analyzed at the end.

  10. Production of plastic scintillation survey meter for clearance verification measurement

    International Nuclear Information System (INIS)

    Tachibana, Mitsuo; Shiraishi, Kunio; Ishigami, Tsutomu; Tomii, Hiroyuki

    2008-03-01

    In the Nuclear Science Research Institute, the decommissioning of various nuclear facilities is carried out according to the plan for meeting the midterm goal of the Japan Atomic Energy Agency (JAEA). An increase in the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas will be expected along with the dismantlement of nuclear facilities in the future. The radiation measurement for releasing controlled areas has been carried out in small-scale nuclear facilities including the JPDR (Japan Power Demonstration Reactor). However, the radiation measurement with an existing measuring device was difficult in effects of radiation from radioactive materials that remains in buried piping. On the other hand, there is no experience that the clearance verification measurement is executed in the JAEA. The generation of a large amount of clearance object will be expected along with the decommissioning of the nuclear facilities in the future. The plastic scintillation survey meter (hereafter, 'PL measuring device') was produced to apply to the clearance verification measurement and the radiation measurement for releasing controlled areas. The basic characteristic test and the actual test were confirmed using the PL measuring device. As a result of these tests, it was found that the evaluation value of radioactivity with the PL measuring device was accuracy equal with the existing measuring device. The PL measuring device has feature of the existing measuring device with a light weight and easy operability. The PL measuring device can correct the gamma ray too. The PL measuring device is effective to the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas. (author)

  11. [Airway clearance techniques in chronic obstructive pulmonary syndrome : 2011 update].

    Science.gov (United States)

    Opdekamp, C

    2011-09-01

    For many years the airway clearance techniques used in chest physical therapy were assimilated with the singular technique of postural drainage, percussions and vibrations. However the side effects and counter indications and the lack of scientific proof regarding this technique have forced reflection and development of other techniques more comfortable and without deleterious effects. If all these techniques show a high efficiency in terms of improved mucociliary clearance, the literature is unanimous on how little effect these techniques have in the short and the long-term with regards to lung function and arterial blood gases. In view of the scientific literature, it is clear that the airway clearance techniques don't have the same recognition concerning their efficiency in all obstructive pulmonary diseases. As the cornerstone in the management of cystic fibrosis, the efficiency of the bronchial hygiene techniques are in general poorly documented in the management of the non-cystic fibrosis bronchiectasis, bronchitis or emphysema. The use of the chest physical therapy seems more to do with the interpretation of the imagery and symptomatology. The airway clearance techniques should be individualised according to symptoms, the amount of expectorated mucus and the objectives signs of secretions retention or subjective signs of difficulty expectorating secretions with progression of the disease.

  12. Study of the capacitance technique for measuring high-temperature blade tip clearance on ceramic rotors

    Science.gov (United States)

    Barranger, John P.

    1993-01-01

    Higher operating temperatures required for increased engine efficiency can be achieved by using ceramic materials for engine components. Ceramic turbine rotors are subject to the same limitations with regard to gas path efficiency as their superalloy predecessors. In this study, a modified frequency-modulation system is proposed for the measurement of blade tip clearance on ceramic rotors. It is expected to operate up to 1370 C (2500 F), the working temperature of present engines with ceramic turbine rotors. The design of the system addresses two special problems associated with nonmetallic blades: the capacitance is less than that of a metal blade and the effects of temperature may introduce uncertainty with regard to the blade tip material composition. To increase capacitance and stabilize the measurement, a small portion of the rotor is modified by the application of 5-micron-thick platinum films. The platinum surfaces on the probe electrodes and rotor that are exposed to the high-velocity gas stream are coated with an additional 10-micron-thick protective ceramic topcoat. A finite-element method is applied to calculate the capacitance as a function of clearance.

  13. Factors affecting lower calyceal stone clearance after Extracorporeal shock wave lithotripsy

    Directory of Open Access Journals (Sweden)

    S. Azab

    2013-03-01

    Conclusions: There is no statistically significant effect of stone size, anatomy of the lower calyx and BMI on stone clearance after ESWL of lower calyceal stones. However, small stone size (≤2 cm, a shorter and wider infundibulum and a larger lower-pole infundibulopelvic angle seem to promote a more rapid and more complete stone clearance.

  14. Chromium-51-EDTA clearance in adults with a single-plasma sample.

    Science.gov (United States)

    Mårtensson, J; Groth, S; Rehling, M; Gref, M

    1998-12-01

    In 1996, a committee on renal clearance recommended a mean sojourn time-based methodology for single-sample determination of plasma clearance of 99mTc-diethylenetriamine pentaacetic acid (DTPA) to be used on adults if the patient's glomerular filtration rate (GFR) is suspected to be >30 ml/min. The main purpose of this study was to derive a mean sojourn time-based formula for calculation of 51Cr-ethylenediamine tetraacetic acid (EDTA) clearance in adults. Two groups of patients with 51Cr-EDTA clearance (Cl) between 16 and 172 ml/min were studied. In Group I (n = 46), reference Cl was determined as a multiplasma sample, single-injection method (ClSM). Sixteen blood samples were drawn from 0 until 5 hr after a single intravenous injection of 51Cr-EDTA. In Group II (n = 1046), reference Cl was determined by the Brøchner-Mortensen four-sample clearance method (ClBM). The plasma time-activity curves of Group I were used to derive two mean sojourn time-based formulas (Formulas 1 and 2) for calculation of a single-sample clearance. Formula 1 was derived from the entire time-activity curve, whereas the derivation of Formula 2 used only the final slope of the time-activity curve. The accuracy of the two formulas and the Christensen and Groth 99mTc-DTPA formula was tested on Group II. Chromium-51-EDTA Cl calculated by Formula 1 was almost identical to the Cl calculated by the reference Cl method (r = 0.982; SDdiff = 5.82 ml/min). Both 51Cr-EDTA Cl calculated by Formula 2 and by the 99mTc-DTPA formula showed close correlation with the reference method (r = 0.976, r = 0.985, respectively) but systematically overestimated GFR for the whole range of clearance values by 3.5 and 3.2 ml/min (ptime methodology. The determination is marginally more accurate (ptime-activity curve than from only the final slope. The single-sample formula derived for determination of 99mTc-DTPA Cl tends slightly to overestimate GFR if used to calculate 51Cr-EDTA Cl.

  15. Clearance of material with negligible levels of radioactivity based on the amended German radiation protection ordinance

    International Nuclear Information System (INIS)

    Schaller, G.; Bayer, A.

    2002-01-01

    For the first time the modalities for the clearance of relevant materials have been laid down in the amended Radiation Protection Ordinance in a comprehensive form. A distinction is made between unconditional clearance and cases of clearance in which disposal, recycling, and re-use is prescribed. The focus of attention in the case of unconditional clearance consists in special consideration of large volumes of building rubble and excavated soil. Material can only be released from supervision under the Atomic Energy Act, when the radiation-related risk, and correspondingly, also the dose from material issued with clearance, are at negligible levels. In order to facilitate the practical application of clearance, values have been derived on the basis of scenarios which cover all radiation exposures which can reasonably be considered. (orig.) [de

  16. Transplacental clearance and blood flows of bovine gravid uterus at several stages of gestation

    International Nuclear Information System (INIS)

    Reynolds, L.P.; Ferrell, C.L.

    1987-01-01

    Rates of uterine and umbilical blood flows and transplacental clearance of deuterium oxide (D 2 O) were determined for cows on 137 +/- 1.0 (SE, n = 9), 180 +/- 0.5 (n = 8), 226 +/- 0.4 (n = 9), and 250 +/- 1.8 (n = 5) days of gestation. From days 137 to 250, rates increased 4.5-fold for uterine blood flow, 21-fold for umbilical blood flow, and 14-fold for clearance of D 2 O. Changes in rates of umbilical blood flow and D 2 O clearance paralleled increased rates of fetal growth and metabolism, which have previously been reported to occur during the last half of gestation. The regressions of D 2 O clearance on uterine and umbilical blood flows were significant (P less than 0.01) and explained 94-99% of the variation in placental clearance of D 2 O. Because the rate of D 2 O clearance was always less than that of uterine and umbilical blood flows, and because a relatively simple statistical model explained most of the variation in clearance, it was suggested that a concurrent or countercurrent arrangement of maternal and fetal placental microvasculatures is not adequate to explain clearance of highly diffusable substances across the bovine placenta. In addition, a placental exchange diagram of the data showed the existence of severe uneven distribution of maternal and fetal placental blood flows and/or significant shunting of maternal and fetal placental flows away from areas of exchange. Taken together, these data indicate that the placenta of the cow, like those of the sheep and goat, represents a relatively inefficient system of transplacental exchange

  17. Small solute clearance from the lungs of patients with cardiogenic and noncardiogenic pulmonary edema

    International Nuclear Information System (INIS)

    Mason, G.R.; Effros, R.M.; Uszler, J.M.; Mena, I.

    1985-01-01

    The regional clearance of /sup 99m/Tc-diethylenetriamine penta-acetate from the lungs was measured in 14 patients with noncardiogenic pulmonary edema, six patients with acute pulmonary edema secondary to heart failure, and 29 normal subjects. The radionuclide was delivered in an aerosol which was inhaled for 120 seconds, and the subsequent decline of radioactivity from the lungs was monitored for seven minutes over each of six peripheral regions of interest with a computerized scintillation camera. The average /sup 99m/Tc-DTPA clearance of these regions was accelerated above the 98 percent confidence limits in all but three of the patients with noncardiogenic edema. The mean clearance value in this group of patients was significantly greater than those in normal subjects or patients with cardiogenic pulmonary edema. Clearances returned toward normal in each of seven subjects who improved clinically. Only one of the patients with cardiogenic pulmonary edema had an elevated average clearance rate, and the mean clearance for this population was not statistically greater than normal. This procedure appears to detect increased epithelial permeability caused by lung injury and may help distinguish between cardiogenic and noncardiogenic pulmonary edema

  18. Improving accuracy of ET measurement of LISS nozzle to calandria tube clearance

    International Nuclear Information System (INIS)

    Craig, S.T.; Krause, T.W.; Schankula, J.J.

    2006-01-01

    The AECL Fuel Channel Inspection System (AFCIS) has been used in an in-reactor field trial to successfully measure the clearance between Liquid Injection Shutdown System (LISS) nozzles and calandria tubes. Each measurement over the full length of a channel added only 15 minutes to the on-channel inspection time. No changes were required to the inspection heads. The only equipment changes made were the addition of a Remote Field Eddy Current (RFEC) module to the eddy current instrument, and minor wiring changes, at the instrument, to achieve a RFEC configuration. With the experience gained from the field trial, factors potentially limiting accuracy were identified. These, and other factors, were investigated and are discussed herein. The RFEC probe is delivered inside the pressure tube. Magnetic fields from the RFEC probe extend through the conducting walls of the pressure tube and calandria tube to interact with the LISS nozzle. Data acquired during the field trial showed the LISS nozzle signal is distinct and the signal-to-noise ratio is very favourable. Nevertheless, comparison of the RFEC measurements to a visual examination, made during the same outage, had the RFEC method underestimating the clearance by 2.5 mm on average. By way of laboratory tests, the following factors were investigated as potential sources of error: resistivity and geometry of LISS nozzle reference/calibration pieces, pressure-tube wall thickness, diameter and resistivity variations, pressure-tube to calandria-tube gap, and radial offsets of the probe within the pressure-tube. The sensitivity to these various noise sources was established. A model, based on fundamental electromagnetic principles, was developed and was used to normalize the effects of LISS nozzle conductivity and geometry. This enabled compensation for various sources of error, and made it possible to produce a correction factor for the field trial data, reducing the average difference from the visual inspection of LISS

  19. Waste-clearance strategy for DOE waste processed at commercial facilities

    International Nuclear Information System (INIS)

    Chen, S.Y.; Pfingston, M.; LePoire, D.

    1996-01-01

    In May 1991, a moratorium was issued on shipping potentially mixed waste from DOE facilities nationwide to commercial treatment, storage, and disposal facilities. A potential waste-clearance strategy was developed to address the DOE mixed-waste moratorium issues, which had resulted from a lack of exisitng volume contamination regulations. This strategy also has important potential applications for establishing site clearance limits that ensure worker and public risks remain well below regulatory limits

  20. Plasma clearance of noradrenaline does not change with age in normal subjects

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1985-01-01

    Noradrenaline kinetics (plasma concentrations, plasma clearance and appearance rates) were investigated in seven elderly healthy subjects and in six young healthy subjects. Forearm venous plasma noradrenaline concentrations were higher in the elderly subjects compared with the young subjects. Pla....... Plasma clearance of noradrenaline was identical in the two groups. The increase in plasma noradrenaline concentration, with age, probably reflects an increased sympathetic nervous activity.......Noradrenaline kinetics (plasma concentrations, plasma clearance and appearance rates) were investigated in seven elderly healthy subjects and in six young healthy subjects. Forearm venous plasma noradrenaline concentrations were higher in the elderly subjects compared with the young subjects...

  1. The kidneys play a central role in the clearance of rhGH in rats

    DEFF Research Database (Denmark)

    Vestergaard, Bill; Thygesen, Peter; Kreilgaard, Mads

    2016-01-01

    at treatment of patients with growth hormone disorders. The purpose of this study was to investigate the relative importance of the kidneys in the clearance of rhGH. The study employed a newly validated nephrectomy rat model and a population based pharmacokinetic approach to assess renal clearance of rh...... that renal clearance plays a pivotal role in the elimination of rhGH in rats....

  2. Low ground clearance vehicle detection and warning.

    Science.gov (United States)

    2015-06-01

    A Low Ground Clearance Vehicle Detection : System (LGCVDS) determines if a commercial : motor vehicle can successfully clear a highwayrail : grade crossing and notifies the driver when : his or her vehicle cannot safely traverse the : crossing. That ...

  3. The tribological behaviour of different clearance MOM hip joints with lubricants of physiological viscosities.

    Science.gov (United States)

    Hu, X Q; Wood, R J K; Taylor, A; Tuke, M A

    2011-11-01

    Clearance is one of the most influential parameters on the tribological performance of metal-on-metal (MOM) hip joints and its selection is a subject of considerable debate. The objective of this paper is to study the lubrication behaviour of different clearances for MOM hip joints within the range of human physiological and pathological fluid viscosities. The frictional torques developed by MOM hip joints with a 50 mm diameter were measured for both virgin surfaces and during a wear simulator test. Joints were manufactured with three different diametral clearances: 20, 100, and 200 microm. The fluid used for the friction measurements which contained different ratios of 25 percent newborn calf serum and carboxymethyl cellulose (CMC) with the obtained viscosities values ranging from 0.001 to 0.71 Pa s. The obtained results indicate that the frictional torque for the 20 microm clearance joint remains high over the whole range of the viscosity values. The frictional torque of the 100 microm clearance joint was low for the very low viscosity (0.001 Pa s) lubricant, but increased with increasing viscosity value. The frictional torque of the 200 microm clearance joint was high at very low viscosity levels, however, it reduced with increasing viscosity. It is concluded that a smaller clearance level can enhance the formation of an elastohydrodynamic lubrication (EHL) film, but this is at the cost of preventing fluid recovery between the bearing surfaces during the unloaded phase of walking. Larger clearance bearings allow a better recovery of lubricant during the unloaded phase, which is necessary for higher viscosity lubricants. The selection of the clearance value should therefore consider both the formation of the EHL film and the fluid recovery as a function of the physiological viscosity in order to get an optimal tribological performance for MOM hip joints. The application of either 25 per cent bovine serum or water in existing in vitro tribological study should

  4. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan.

    Science.gov (United States)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-11-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) "Regulations on Clearance Level for Radioactive Waste Management". The testing results should conform to the deviation and traceability requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Not All Children with Cystic Fibrosis Have Abnormal Esophageal Neutralization during Chemical Clearance of Acid Reflux.

    Science.gov (United States)

    Woodley, Frederick W; Moore-Clingenpeel, Melissa; Machado, Rodrigo Strehl; Nemastil, Christopher J; Jadcherla, Sudarshan R; Hayes, Don; Kopp, Benjamin T; Kaul, Ajay; Di Lorenzo, Carlo; Mousa, Hayat

    2017-09-01

    Acid neutralization during chemical clearance is significantly prolonged in children with cystic fibrosis, compared to symptomatic children without cystic fibrosis. The absence of available reference values impeded identification of abnormal findings within individual patients with and without cystic fibrosis. The present study aimed to test the hypothesis that significantly more children with cystic fibrosis have acid neutralization durations during chemical clearance that fall outside the physiological range. Published reference value for acid neutralization duration during chemical clearance (determined using combined impedance/pH monitoring) was used to assess esophageal acid neutralization efficiency during chemical clearance in 16 children with cystic fibrosis (3 to chemical clearance exceeded the upper end of the physiological range in 9 of 16 (56.3%) children with and in 3 of 16 (18.8%) children without cystic fibrosis ( p =0.0412). The likelihood ratio for duration indicated that children with cystic fibrosis are 2.1-times more likely to have abnormal acid neutralization during chemical clearance, and children with abnormal acid neutralization during chemical clearance are 1.5-times more likely to have cystic fibrosis. Significantly more (but not all) children with cystic fibrosis have abnormally prolonged esophageal clearance of acid. Children with cystic fibrosis are more likely to have abnormal acid neutralization during chemical clearance. Additional studies involving larger sample sizes are needed to address the importance of genotype, esophageal motility, composition and volume of saliva, and gastric acidity on acid neutralization efficiency in cystic fibrosis children.

  6. Dextran fractional clearance studies in acute dengue infection.

    Directory of Open Access Journals (Sweden)

    Julie Nguyen-Pouplin

    2011-08-01

    Full Text Available Although increased capillary permeability is the major clinical feature associated with severe dengue infections the mechanisms underlying this phenomenon remain unclear. Dextran clearance methodology has been used to investigate the molecular sieving properties of the microvasculature in clinical situations associated with altered permeability, including during pregnancy and in various renal disorders. In order to better understand the characteristics of the vascular leak associated with dengue we undertook formal dextran clearance studies in Vietnamese dengue patients and healthy volunteers.We carried out serial clearance studies in 15 young adult males with acute dengue and evidence of vascular leakage a during the phase of maximal leakage and b one and three months later, as well as in 16 healthy control subjects. Interestingly we found no difference in the clearance profiles of neutral dextran solutions among the dengue patients at any time-point or in comparison to the healthy volunteers.The surface glycocalyx layer, a fibre-matrix of proteoglycans, glycosaminoglycans, and plasma proteins, forms a complex with the underlying endothelial cells to regulate plasma volume within circumscribed limits. It is likely that during dengue infections loss of plasma proteins from this layer alters the permeability characteristics of the complex; physical and/or electrostatic interactions between the dextran molecules and the glycocalyx structure may temporarily restore normal function, rendering the technique unsuitable for assessing permeability in these patients. The implications for resuscitation of patients with dengue shock syndrome (DSS are potentially important. It is possible that continuous low-dose infusions of dextran may help to stabilize the permeability barrier in patients with profound or refractory shock, reducing the need for repeated boluses, limiting the total colloid volume required. Formal clinical studies should help to assess

  7. Surface code—biophysical signals for apoptotic cell clearance

    International Nuclear Information System (INIS)

    Biermann, Mona; Maueröder, Christian; Brauner, Jan M; Chaurio, Ricardo; Herrmann, Martin; Muñoz, Luis E; Janko, Christina

    2013-01-01

    Apoptotic cell death and the clearance of dying cells play an important and physiological role in embryonic development and normal tissue turnover. In contrast to necrosis, apoptosis proceeds in an anti-inflammatory manner. It is orchestrated by the timed release and/or exposure of so-called ‘find-me’, ‘eat me’ and ‘tolerate me’ signals. Mononuclear phagocytes are attracted by various ‘find-me’ signals, including proteins, nucleotides, and phospholipids released by the dying cell, whereas the involvement of granulocytes is prevented via ‘stay away’ signals. The exposure of anionic phospholipids like phosphatidylserine (PS) by apoptotic cells on the outer leaflet of the plasma membrane is one of the main ‘eat me’ signals. PS is recognized by a number of innate receptors as well as by soluble bridging molecules on the surface of phagocytes. Importantly, phagocytes are able to discriminate between viable and apoptotic cells both exposing PS. Due to cytoskeleton remodeling PS has a higher lateral mobility on the surfaces of apoptotic cells thereby promoting receptor clustering on the phagocyte. PS not only plays an important role in the engulfment process, but also acts as ‘tolerate me’ signal inducing the release of anti-inflammatory cytokines by phagocytes. An efficient and fast clearance of apoptotic cells is required to prevent secondary necrosis and leakage of intracellular danger signals into the surrounding tissue. Failure or prolongation of the clearance process leads to the release of intracellular antigens into the periphery provoking inflammation and development of systemic inflammatory autoimmune disease like systemic lupus erythematosus. Here we review the current findings concerning apoptosis-inducing pathways, important players of apoptotic cell recognition and clearance as well as the role of membrane remodeling in the engulfment of apoptotic cells by phagocytes. (paper)

  8. Nasal deposition and clearance in man: comparison of a bidirectional powder device and a traditional liquid spray pump.

    Science.gov (United States)

    Djupesland, Per Gisle; Skretting, Arne

    2012-10-01

    Delivery of powder formulations to the nose is an attractive alternative for many drugs and vaccines. This study compared the regional nasal deposition and clearance patterns of lactose powder delivered by the OptiNose powder device (Opt-Powder; OptiNose US Inc., Yardley, PA, USA) to that of liquid aerosol administered via a traditional hand-actuated liquid spray pump (Rexam SP270, Rexam Pharma, France). The study was an open-label, crossover design in seven healthy subjects (five females, two males). The regional nasal deposition and clearance patterns of the Opt-Powder device were compared to a traditional liquid spray pump by dynamic gamma camera imaging after administration of either (99m)Tc-labeled lactose powder or liquid (99m)Tc- diethelyne triamine pentaacetic acid-aerosol. The gamma camera images were scaled and aligned with sagittal magnetic resonance images to identify nasal regions. Possible deposition of radiolabeled material in the lungs following both methods of delivery was also evaluated. Both powder and spray were distributed to all of the nasal regions. The Opt-Powder device, however, achieved significantly larger initial deposition in the upper and middle posterior regions of the nose than spray (upper posterior region; Opt-Powder 18.3% ± 11.5 vs. Spray 2.4% ± 1.8, pSpray 15.7% ± 13.8, pdeposition to the lower anterior and posterior regions for spray was three times higher compared to Opt-Powder (Opt-Powder 17.4% ± 24.5 vs. Spray 59.4% ± 18.2, pdeposition was observed. The initial deposition following powder delivery was significantly larger in the ciliated mucosa of the upper and posterior nasal regions, whereas less was deposited in the lower regions. Overall nasal clearance of powder was slower initially, but due to retention in anterior nonciliated regions the overall nasal clearance after spray was slower.

  9. Trend of research and development on clearance system for CBRNE agents

    International Nuclear Information System (INIS)

    Ishihara, Masayuki; Fujita, Masanori; Ishida, Natsuko; Hattori, Hidemi; Tachibana, Shoich; Nakamura, Shingo; Kanatani, Yasuhiro

    2013-01-01

    In a field of disaster for a wide variety of Chemical, Biological, Radiological, Nuclear, Explosive (CBRNE) agents which are harmful and deadly poisonous, it is crucial to effectively clear those agents for prevention of expanded damages and retrieval from damage. The clearance technologies in the CBRNE disaster field require to be safe for human body and to be friendly for the environments. In addition, they need scientific data-based evidences for their effectiveness and safety. The aim of this article is to view the trend of research on clearances of N, B and c agents in terms of rapidity, simplicity and economic rationality, and to deliberate on effective clearance system using adequate equipments and materials for detoxification, decomposition and removal of each contamination. (author)

  10. Rate-Based Model Predictive Control of Turbofan Engine Clearance

    Science.gov (United States)

    DeCastro, Jonathan A.

    2006-01-01

    An innovative model predictive control strategy is developed for control of nonlinear aircraft propulsion systems and sub-systems. At the heart of the controller is a rate-based linear parameter-varying model that propagates the state derivatives across the prediction horizon, extending prediction fidelity to transient regimes where conventional models begin to lose validity. The new control law is applied to a demanding active clearance control application, where the objectives are to tightly regulate blade tip clearances and also anticipate and avoid detrimental blade-shroud rub occurrences by optimally maintaining a predefined minimum clearance. Simulation results verify that the rate-based controller is capable of satisfying the objectives during realistic flight scenarios where both a conventional Jacobian-based model predictive control law and an unconstrained linear-quadratic optimal controller are incapable of doing so. The controller is evaluated using a variety of different actuators, illustrating the efficacy and versatility of the control approach. It is concluded that the new strategy has promise for this and other nonlinear aerospace applications that place high importance on the attainment of control objectives during transient regimes.

  11. Recombinant adeno-associated virus: efficient transduction of the rat VMH and clearance from blood.

    Directory of Open Access Journals (Sweden)

    Margriet A van Gestel

    Full Text Available To promote the efficient and safe application of adeno-associated virus (AAV vectors as a gene transfer tool in the central nervous system (CNS, transduction efficiency and clearance were studied for serotypes commonly used to transfect distinct areas of the brain. As AAV2 was shown to transduce only small volumes in several brain regions, this study compares the transduction efficiency of three AAV pseudotyped vectors, namely AAV2/1, AAV2/5 and AAV2/8, in the ventromedial nucleus of the hypothalamus (VMH. No difference was found between AAV2/1 and AAV2/5 in transduction efficiency. Both AAV2/1 and AAV2/5 achieved a higher transduction rate than AAV2/8. One hour after virus administration to the brain, no viral particles could be traced in blood, indicating that no or negligible numbers of virions crossed the blood-brain barrier. In order to investigate survival of AAV in blood, clearance was determined following systemic AAV administration. The half-life of AAV2/1, AAV2/2, AAV2/5 and AAV2/8 was calculated by determining virus clearance rates from blood after systemic injection. The half-life of AAV2/2 was 4.2 minutes, which was significantly lower than the half-lives of AAV2/1, AAV2/5 and AAV2/8. With a half-life of more than 11 hours, AAV2/8 particles remained detectable in blood significantly longer than AAV2/5. We conclude that application of AAV in the CNS is relatively safe as no AAV particles are detectable in blood after injection into the brain. With a half-life of 1.67 hours of AAV2/5, a systemic injection with 1×109 genomic copies of AAV would be fully cleared from blood after 2 days.

  12. A parameters optimization method for planar joint clearance model and its application for dynamics simulation of reciprocating compressor

    Science.gov (United States)

    Hai-yang, Zhao; Min-qiang, Xu; Jin-dong, Wang; Yong-bo, Li

    2015-05-01

    In order to improve the accuracy of dynamics response simulation for mechanism with joint clearance, a parameter optimization method for planar joint clearance contact force model was presented in this paper, and the optimized parameters were applied to the dynamics response simulation for mechanism with oversized joint clearance fault. By studying the effect of increased clearance on the parameters of joint clearance contact force model, the relation of model parameters between different clearances was concluded. Then the dynamic equation of a two-stage reciprocating compressor with four joint clearances was developed using Lagrange method, and a multi-body dynamic model built in ADAMS software was used to solve this equation. To obtain a simulated dynamic response much closer to that of experimental tests, the parameters of joint clearance model, instead of using the designed values, were optimized by genetic algorithms approach. Finally, the optimized parameters were applied to simulate the dynamics response of model with oversized joint clearance fault according to the concluded parameter relation. The dynamics response of experimental test verified the effectiveness of this application.

  13. Cerebrospinal fluid clearance in Alzheimer disease measured with dynamic PET

    DEFF Research Database (Denmark)

    De Leon, Mony J.; Li, Yi; Okamura, Nobuyuki

    2017-01-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribrif......Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing...

  14. Influence of tip clearance on flow behavior and noise generation of centrifugal compressors in near-surge conditions

    International Nuclear Information System (INIS)

    Galindo, J.; Tiseira, A.; Navarro, R.; López, M.A.

    2015-01-01

    Highlights: • Centrifugal compressor aeroacoustics sensitivity to tip clearance is investigated. • 3 different clearance ratios are set in accordance to expected operating values. • Pressure spectra do not depend on tip clearance ratio in near-surge conditions. • DES performs better than URANS in predicting compressor acoustic signature. • Flow field observation reveals that tip clearance is immersed in rotating backflow. - Abstract: CFD has become an essential tool for researchers to analyze centrifugal compressors. Tip leakage flow is usually considered one of the main mechanisms that dictate compressor flow field and stability. However, it is a common practice to rely on CAD tip clearance, even though the gap between blades and shroud changes when compressor is running. In this paper, sensitivity of centrifugal compressor flow field and noise prediction to tip clearance ratio is investigated. 3D CFD simulations are performed with three different tip clearance ratios in accordance to expected operating values, extracted from shaft motion measurements and FEM predictions of temperature and rotational deformation. Near-surge operating conditions are simulated with URANS and DES. DES shows superior performance for acoustic predictions. Cases with reduced tip clearance present higher pressure ratio and isentropic efficiency, but no significant changes in compressor acoustic signature are found when varying clearance. In this working point, tip clearance is immersed in a region of strongly swirling backflow. Therefore, tip leakage cannot establish any coherent noise source mechanism

  15. Decreased insulin clearance in individuals with elevated 1-h post-load plasma glucose levels.

    Directory of Open Access Journals (Sweden)

    Maria Adelaide Marini

    Full Text Available Reduced insulin clearance has been shown to predict the development of type 2 diabetes. Recently, it has been suggested that plasma glucose concentrations ≥ 8.6 mmol/l (155 mg/dl at 1 h during an oral glucose tolerance test (OGTT can identify individuals at high risk for type 2 diabetes among those who have normal glucose tolerance (NGT 1 h-high. The aim of this study was to examine whether NGT 1 h-high have a decrease in insulin clearance, as compared with NGT individuals with 1-h post-load glucose <8.6 mmol/l (l (155 mg/dl, NGT 1 h-low. To this end, 438 non-diabetic White individuals were subjected to OGTT and euglycemic-hyperinsulinemic clamp to evaluate insulin clearance and insulin sensitivity. As compared with NGT 1 h-low individuals, NGT 1 h-high had significantly higher 1-h and 2-h post-load plasma glucose and 2-h insulin levels as well as higher fasting glucose and insulin levels. NGT 1 h-high exhibited also a significant decrease in both insulin sensitivity (P<0.0001 and insulin clearance (P = 0.006 after adjusting for age, gender, adiposity measures, and insulin sensitivity. The differences in insulin clearance remained significant after adjustment for fasting glucose (P = 0.02 in addition to gender, age, and BMI. In univariate analyses adjusted for gender and age, insulin clearance was inversely correlated with body weight, body mass index, waist, fat mass, 1-h and 2-h post-load glucose levels, fasting, 1-h and 2-h post-load insulin levels, and insulin-stimulated glucose disposal. In conclusion, our data show that NGT 1 h-high have a reduction in insulin clearance as compared with NGT 1 h-low individuals; this suggests that impaired insulin clearance may contribute to sustained fasting and post-meal hyperinsulinemia.

  16. The Swedish nuclear industry way to approach higher demands on characterisation prior to clearance

    International Nuclear Information System (INIS)

    Larsson, Arne; Hellsten, Erik; Berglund, Malin; Larsson, Lars

    2012-01-01

    The Swedish Radiation Safety Authority (SSM) has introduced new regulations for clearance SSMFS 2011:2 'Regulations concerning clearance of material, rooms, buildings and soil from activities with ionizing radiation'. The new regulations came into force January 1, 2012. Compared to the previous regulations these new regulations have a broader scope and have introduced new conditions such as nuclide specific clearance levels. Clearance is practiced to reduce the amount of radioactive waste generated. Cleared material can be reused, recycled or if these two possibilities are not available, disposed of as conventional waste. To be able to meet the requirements for clearance the Swedish nuclear industry has jointly developed guidance for clearance in the form of a handbook and a training course covering the competence requirements in the new regulations. The handbook was developed by a team of representatives from the Swedish nuclear license holders managed by Studsvik on behalf of Swedish Nuclear Fuel and Waste Management Company (SKB). The training program was developed in co-operation between Nuclear Safety and training Company (KSU) and Studsvik on behalf of the Swedish nuclear license holders. A major challenge in the adoption to the new regulations is how to provide robust yet cost effective characterisation data. This is especially difficult for mobile materials and equipment which cannot be fully tracked but also for other materials and areas where the nuclide fingerprint has varied over the years. To be able to deal with these issues a lot of attention has to be paid to the historical inventory records and traceability in the clearance process. Materials, rooms and buildings have been divided in four categories with different requirements on frequency and requirements of measurements. The categories are named 'extremely small risk', 'small risk', 'risk' and 'known contamination above clearance levels'. The two day training course is dived into seven parts

  17. Quantitative assessment of caffeine partial clearances in man.

    Science.gov (United States)

    Lelo, A; Miners, J O; Robson, R A; Birkett, D J

    1986-01-01

    Five subjects who participated in an earlier study (Lelo et al., 1986b) of the comparative pharmacokinetics of caffeine (CA) and its primary monodemethylated metabolites paraxanthine (PX), theobromine (TB) and theophylline (TP) were administered CA to steady-state. Using areas under the plasma concentration-time curves for each of the dimethylxanthines derived from CA in the steady-state study and individual plasma clearances of PX, TB and TP determined in the previous study, the fractional conversion of CA to PX, TB and TP and the individual partial clearances of CA have been defined. The mean (+/- s.d.) fractional conversion of CA to PX, TB and TP was 79.6 +/- 21.0%, 10.8 +/- 2.4% and 3.7 +/- 1.3%, respectively. When only demethylation pathways are considered PX, TB and TP accounted for 83.9 +/- 5.4%, 12.1 +/- 4.1% and 4.0 +/- 1.4%, respectively of the CA demethylations. The mean partial clearance of CA to PX was approximately 8-fold and 23-fold greater than those to TB and TP respectively. These data confirm earlier reports that PX is the major metabolite of CA in humans but suggest that PX formation is quantitatively more important than previously believed. PMID:3756066

  18. Decision Assessment of Clearance Level on Radioactive Waste Management

    International Nuclear Information System (INIS)

    Zainus Salimin; Gunandjar

    2007-01-01

    Radioactive waste on the safe level activity containing very small radioactive material gives small radiology influence to the human, it is not necessary to control by regulatory body. The radioactive waste on the safe level activity is safe to release as the common waste. For exemption of the control, it is required the safe activity level limits in which the value of clearance level is fulfilled by regulatory body, however until now it is not decided yet. The exemption decision is obtained if its activity is lower than or same with clearance level based on the annual effective dose receiving by public on the value is lower than or same with 0,01 mSv. The exposure pathways of radioactive waste to the human have important role for determination of clearance level. The decision assessment of clearance level on the radioactive waste management has been done by analysis of radioactive exposure pathways to the human for activities of the disposal and the recycle of solid wastes, also the release of liquid and gas effluent. For solid waste disposal, the exposure pathway was evaluated since the transportation of packed waste from the treatment facility to the disposal facility and during its operation. Exposure pathways for solid waste recycle consist of the pathways for handling and transportation of cleared material to the recycling facility, the fabrication and the utilization of its product. Exposure pathways for liquid and gas releases occur since its releases to the environment up to the human (public) by specific traffic lane. (author)

  19. Bromsulphalein (BSP) clearance in ageing rats

    NARCIS (Netherlands)

    Hollander, C.F.; Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.

    1968-01-01

    Liver function in ageing rats was studied, using the bromsulphalein (BSP) clearance test. The test was done on ultramicro scale. This made it possible to repeat the test several times in the same animal and to start a longitudinal study. In 3-month-old rats the BSP retentions, measured 15, 30 and 45

  20. Non-destructive clearance measuring in closed joints

    International Nuclear Information System (INIS)

    Doucelance, C.; Manaranche, J.C.

    1976-01-01

    Two methods for clearance measuring in closed joints are described. The first one is based on the mechanical impedance concept, while the other one requires a shock test on shaker. Both are illustrated with an example of application [fr

  1. Hyperinsulinism and polycystic ovary syndrome (PCOS): role of insulin clearance.

    Science.gov (United States)

    Amato, M C; Vesco, R; Vigneri, E; Ciresi, A; Giordano, C

    2015-12-01

    Insulin resistance and compensatory hyperinsulinism are the predominant metabolic defects in polycystic ovary syndrome (PCOS). However, hyperinsulinism, as well as being compensatory, can also express a condition of reduced insulin clearance. Our aim was to evaluate the differences in insulin action and metabolism between women with PCOS (with normal glucose tolerance) and age- and BMI-matched women with prediabetes (without hyperandrogenism and ovulatory disorders). 22 women with PCOS and 21 age/BMI-matched women with prediabetes were subjected to a Hyperinsulinemic-euglycemic clamp and an Oral Glucose tolerance Test (OGTT). Insulin sensitivity was assessed by the glucose infusion rate during clamp (M value); insulin secretion by Insulinogenic index, Oral Disposition Index (DIo) and AUC(2h-insulin) during OGTT; and insulin clearance by the metabolic clearance rate of insulin (MCRI) during clamp. Women with PCOS showed significantly higher levels of AUC(2h-insulin) (p PCOS [420 (IQR 227-588) vs. 743 (IQR 597-888) ml m(-2) min(-1): p PCOS group, a strong independent inverse correlation was only observed between MCRI and AUC(2h-insulin) (PCOS: β:-0.878; p PCOS there is peripheral insulin sensitivity similar to that of women with prediabetes. What sets PCOS apart is the hyperinsulinism, today still simplistically defined "compensatory"; actually this is mainly related to decreased insulin clearance whose specific causes and dynamics have yet to be clarified.

  2. 133 xenon muscle clearance as a test parameter in the diagnosis of peripheral diabetic angiopathies

    International Nuclear Information System (INIS)

    Kuhlmann, J.E.

    1980-01-01

    In 100 patients with manifest diabetes mellitus the irrigation in both legs at rest and in radioactive hyperemia after ischemic muscle work was measured by means of the 133-xenon muscle clearance. The clearance values measured ranged between 0.8 and 3.5 ml/100 g/60 s at rest and between 3.3 and 40.0 ml/100 gl/60 s during radioactive hyperemia. In 96 pc of the probands the irrigation of the legs was impaired. For the relation between glucose level and irrigation at rest a significant negative correlation was found. The difference between the clearance values for the right and left lower extremity was significant. For the relation between glucose level and reactive hyperemia, too, a significant negative correlation was found. The difference between the clearance values for the right and left lower extremities was significant. The measurement of the irrigation at rest showed no significant correlation between the period of manifestation of the diabetes and the clearance values. By contrast, the irrigation values during reactive hyperemia were shown to be in significantly negative correlation to the duration of the diabetes. No connection was found between the frequency of diabetic gangrene and impaired irrigation at rest. By contrast, there was a relation between decreasing hyperemia values and increased frequency of gangrene. A collection of case histories shows how the measuring results of the xenon clearance fit into the overall clinical picture. A comparison of xenon clearance with other methods of irrigation measurement confirmed obvious advantages of xenon clearance for the detection of diabetic microangiopathies. (orig./MG) [de

  3. Serial thallium-201 imaging after dipyridamole for coronary disease detection: quantitative analysis using myocardial clearance

    International Nuclear Information System (INIS)

    Okada, R.D.; Dai, Y.H.; Boucher, C.A.; Pohost, G.M.

    1984-01-01

    After dipyridamole, canine studies have demonstrated a slower rate of myocardial thallium-201 clearance from zones distal to a coronary artery stenosis compared to normal zones. To determine if criteria based on canine myocardial thallium-201 clearance rates could be applied clinically, 40 patients with and 26 patients without coronary artery disease (CAD) had serial thallium-201 images obtained for 2 to 5 hours after dipyridamole. Regions of interest were manually placed over six left ventricular segments in two projections for each of three imaging times. The myocardial thallium-201 clearance rate was calculated for each of the six segments and, using the clearance rate criterion found in canine studies, was considered abnormal if less than 6.5%/hr. Using this criterion alone, 22 of 26 patients (85%) without CAD had normal and 30 of 40 patients (75%) with CAD had abnormal myocardial thallium-201 clearance rates. A quantitative analysis of regional inhomogeneity in tracer distribution (normal was greater than or equal to 25% difference between segments) was negative in 24 of 26 patients (92%) without CAD and positive in 20 of 40 patients (50%) with CAD. When both clearance rate and regional inhomogeneity were considered, 21 of 26 patients (81%) without CAD had negative and 36 of 40 patients (90%) with CAD had positive results. Thus, post-dipyridamole myocardial clearance rate criteria derived from canine studies can be applied to clinical thallium imaging. Quantitative analysis of serial thallium-201 images after dipyridamole is optimized by using myocardial thallium-201 clearance rates. Such an approach is independent of regional inhomogeneities in tracer distribution

  4. TAM receptors in apoptotic cell clearance, autoimmunity, and cancer.

    Science.gov (United States)

    Nguyen, Khanh-Quynh; Tsou, Wen-I; Kotenko, Sergei; Birge, Raymond B

    2013-08-01

    Receptor tyrosine kinases, Tyro-3, Axl and Mer, collectively designated as TAM, are involved in the clearance of apoptotic cells. TAM ligands, Gas6 and Protein S, bind to the surfaces of apoptotic cells, and at the same time, interact directly with TAM expressed on phagocytes, impacting the engulfment and clearance of apoptotic cells and debris. The well-tuned and balanced actions of TAM may affect a variety of human pathologies including autoimmunity, retinal degeneration, and cancer. This article emphasizes some of the emerging findings and mechanistic insights into TAM functions that are clinically relevant and possibly therapeutically targeted.

  5. Lithium clearance and renal tubular sodium handling during acute and long-term nifedipine treatment in essential hypertension

    DEFF Research Database (Denmark)

    Bruun, N E; Ibsen, H; Skøtt, P

    1988-01-01

    1. In two separate studies the lithium clearance method was used to evaluate the influence of acute and long-term nifedipine treatment on renal tubular sodium reabsorption. 2. In the acute study, after a 4 week placebo period two doses of 20 mg of nifedipine decreased supine blood pressure from 155...... were also unchanged, as were potassium clearance, urine flow and body weight. 3. In the long-term study, lithium clearance, glomerular filtration rate, sodium clearance, potassium clearance, urine flow and body fluid volumes were measured after a 4 weeks placebo period and after 6 and 12 weeks....../101 (20.6/13.5) +/- 11/4 (1.5/0.5) to 139/88 (18.5/11.7) +/- 16/9 (2.1/1.2) mmHg (kPa) (means +/- SD; P less than 0.01). Lithium clearance, glomerular filtration rate and sodium clearance did not change. Therefore the calculated values of absolute proximal and absolute distal sodium reabsorption rates...

  6. Effect of tip clearance on performance of small axial hydraulic turbine

    Science.gov (United States)

    Boynton, J. L.; Rohlik, H. E.

    1976-01-01

    The first two stages of a six stage liquid oxygen turbine were tested in water. One and two stage performance was determined for one shrouded and two unshrouded blade end configurations over ranges of clearance and blade-jet speed ratio. First stage, two stage, and second stage efficiencies are included as well as the effect of clearance on mass flow for two stage operation.

  7. Energy Performance and Radial Force of a Mixed-Flow Pump with Symmetrical and Unsymmetrical Tip Clearances

    Directory of Open Access Journals (Sweden)

    Yue Hao

    2017-01-01

    Full Text Available The energy performance and radial force of a mixed flow pump with symmetrical and unsymmetrical tip clearance are investigated in this paper. As the tip clearance increases, the pump head and efficiency both decrease. The center of the radial force on the principal axis is located at the coordinate origin when the tip clearance is symmetrical, and moves to the third quadrant when the tip clearance is unsymmetrical. Analysis results show that the total radial force on the principal axis is closely related to the fluctuation of mass flow rate in each single flow channel. Unsteady simulations show that the dominant frequencies of radial force on the hub and blade correspond to the blade number, vane number, or double blade number because of the rotor stator interaction. The radial force on the blade pressure side decreases with the tip clearance increase because of leakage flow. The unsymmetrical tip clearances in an impeller induce uneven leakage flow rate and then result in unsymmetrical work ability of each blade and flow pattern in each channel. Thus, the energy performance decreases and the total radial force increases for a mixed flow pump with unsymmetrical tip clearance.

  8. 76 FR 24920 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-03

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  9. 76 FR 35069 - Agency Information Collection Activities; Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-06-15

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...; Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  10. 78 FR 74175 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2013-12-10

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  11. 77 FR 52708 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2012-08-30

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  12. 76 FR 9819 - Agency Information Collection Activities: Proposed Collection; Generic Clearance for the...

    Science.gov (United States)

    2011-02-22

    ...; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery; Correction AGENCY...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Regulatory Commission, Office of Personnel Management, Small Business Administration, and U.S. Agency for...

  13. Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Lange, W; Koehler, H; Apodaca, J [Bundesgesundheitsamt, Berlin (Germany, F.R.). Abt. fuer Virologie

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were re-examined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not encountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test.

  14. Turbine Engine Clearance Control Systems: Current Practices and Future Directions

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.

    2002-01-01

    Improved blade tip sealing in the high pressure compressor (HPC) and high pressure turbine (HPT) can provide dramatic reductions in specific fuel consumption (SFC), time-on-wing, compressor stall margin, and engine efficiency as well as increased payload and mission range capabilities. Maintenance costs to overhaul large commercial gas turbine engines can easily exceed $1M. Engine removal from service is primarily due to spent exhaust gas temperature (EGT) margin caused mainly by the deterioration of HPT components. Increased blade tip clearance is a major factor in hot section component degradation. As engine designs continue to push the performance envelope with fewer parts and the market drives manufacturers to increase service life, the need for advanced sealing continues to grow. A review of aero gas turbine engine HPT performance degradation and the mechanisms that promote these losses are discussed. Benefits to the HPT due to improved clearance management are identified. Past and present sealing technologies are presented along with specifications for next generation engine clearance control systems.

  15. Regulation Concepts for Clearance Level of Radionuclide in Solid Materials

    International Nuclear Information System (INIS)

    Nanang Triagung Edi Hermawan

    2008-01-01

    Practices of nuclear energy have expanded in some fields such as researches and development, educations, agricultures, medicines and industries. Every practice beside give much benefit, could generate residue or waste. Radioactive waste needs management to ensure the safety of workers, member of the public, and for the eternal of environment. The product of radioactive waste management, in generally, is some containment of radionuclide concentration in solid matrix material after immobilization or conditioning process. Some kind of processed radioactive wastes with short half live then decay faster to stabile condition. The decay will reach clearance level in sometimes, so from the radiation protection views is harmless. This materials above didn’t need control and must be cleared from all determinate and regulation aspects of radioactive material practices. There is clearance for harmless material off course will be simplify management task and efficiency of money. So the regulation about clearance levels will be important as law basic for technical practices in field. (author)

  16. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-01

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 μm), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm

  17. Understanding of the Interaction between Clearance Leakage Flow and Main Passage Flow in a VGT Turbine

    Directory of Open Access Journals (Sweden)

    Ben Zhao

    2015-02-01

    Full Text Available The clearance flow between the nozzle and endwall in a variable geometry turbine (VGT has been numerically investigated to understand the clearance effect on the VGT performance and internal flow. It was found that the flow rate through turbine increases but the turbine efficiency decreases with height of clearance. Detailed flow field analyses indicated that most of the efficiency loss resulting from the leakage flow occurs at the upstream of the rotor area, that is, in the nozzle endwall clearance and between the nozzle vanes. There are two main mechanisms associated with this efficiency loss. One is due to the formation of the local vortex flow structure between the clearance flow and the main flow. The other is due to the impact of the clearance flow on the main flow after the nozzle throat. This impact reduces the span of shockwave with increased shockwave magnitude by changing the trajectory of the main flow.

  18. The effects of selected air pollutants on clearance of titanic oxide particles from the lungs of rats.

    Science.gov (United States)

    Ferin, J; Leach, L J

    1975-09-01

    A procedure utilizing the lung clearance kinetics of titanic oxide (TiO2) particles was used to determine the effects of inhaled sulphur dioxide (SO2) and nitrogen oxides (NO x) on particle clearance. The procedure is reproducible and mainly tests clearance mechanisms involving alveolar macrophages and the mucociliary transport system at the alveolobronchial clearance pathway. At low SO2 or NOx exposures enhanced particle clearance was observed. Lung clearance was depressed at 15 and 24 ppm of NO2 after 22 exposures as well as at 20 ppm of SO2 after 11 exposures, and also at 1 ppm of SO2 after 25 exposures. Dose-response curves for the SO2 and NOx exposures showed differences explainable by the routes by which these gases reach the alveolar macrophages.

  19. Automated Real-Time Clearance Analyzer (ARCA), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Automated Real-Time Clearance Analyzer (ARCA) addresses the future safety need for Real-Time System-Wide Safety Assurance (RSSA) in aviation and progressively...

  20. 75 FR 38775 - Proposed Information Collection; Comment Request; Generic Clearance for Customer Satisfaction...

    Science.gov (United States)

    2010-07-06

    ...; Generic Clearance for Customer Satisfaction Research AGENCY: U.S. Census Bureau. ACTION: Notice. SUMMARY... Bureau is requesting an extension of the generic clearance to conduct customer satisfaction research... on feedback from its various customer satisfaction research efforts. Each research design is reviewed...

  1. 75 FR 80542 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2010-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  2. 76 FR 12140 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-04

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  3. 76 FR 19826 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-08

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  4. 76 FR 17861 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-31

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  5. 76 FR 41280 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-07-13

    ... proposed sample size, the expected response rate, methods for assessing potential non-response bias, the... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  6. 76 FR 25693 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-05

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  7. Recent studies of float and stall curves in controlled-clearance deadweight testers with a simple piston.

    Science.gov (United States)

    Newhall, D H; Ogawa, I; Zilberstein, V

    1979-08-01

    The effect of piston rotation speed and fluid viscosity on the performance of free-piston gauges with a controlled clearance was studied as part of an experimental program aiming at the better evaluation of pressure by these primary pressure standards. Calculated effective area is shown to be greatly influenced by both speed of rotation and choice of a fluid. An optimum rpm resulting in the smallest possible uncertainty in effective area should be determined experimentally for each fluid and pressure range involved. When all the pertinent parameters are properly selected an appreciable improvement in accuracy can be achieved.

  8. [Medical clearance for missions abroad (EEU): definitions, recommendations for use and performance].

    Science.gov (United States)

    Kollaritsch, Herwig; Wenisch, Christoph; Hatz, Christoph; von Laer, Gunther; Bauer, Bernd; Hollenstein, Ursula; Haditsch, Martin; Diridl, Gerhard; Malinowski, Waldemar; Jeschko, Eva; Payer-Neundlinger, Gabriela; Speiser-Remp, Nicole; Pichler, Hannes E T; Rumpold, Helmut; Stemberger, Heinrich; Eder, Gerald; Wiedermann, Gerhard; Wiedermann, Ursula

    2007-01-01

    Standards for medical clearance for private or business missions abroad are--at least in the German speaking countries--not clearly defined and mostly derived from the old terminus "Tropentauglichkeit" which means fit for mission in the tropics. The authors now define a new standard, called "Entsendungstauglichkeitsuntersuchung" which means clearance of fitness for all types of missions abroad, independent of distinct climatic zones. To meet the inhomogenous requirements of different institutions and different types of missions the medical examination proposed follows a modular structure to optimize economic and medical use of resources. Moreover, as Austria, Germany and Switzerland have different legal and economic postulates, the medical examination has to be adapted to the different premises. The definition and description of this special type of "medical clearance for missions abroad" is supplemented by recommendations for definitions of clients who should undergo such an investigation and the professionals who should perform this type of investigation. Additionally, results of this type of medical clearance are defined and prophylactic aspects in terms of pre-travel advice are mentioned.

  9. Lithium clearance method and the renal response to low-dose dopamine in man

    DEFF Research Database (Denmark)

    Olsen, N V; Olsen, M H; Fogh-Andersen, N

    1993-01-01

    .00 hours on three different occasions. After an overnight fast, the subjects were water-loaded and clearance studies were started at 09.00 hours with a 1h baseline period and three 1h periods during dopamine infusion. 2. Baseline sodium clearance with placebo was 0.65 +/- 0.35 ml/min, but with lithium......-induced changes in effective renal plasma flow, glomerular filtration rate or osmolal clearance. Neither lithium nor dopamine influenced plasma concentrations of renin, aldosterone or atrial natriuretic peptide. 4. In conclusion, single test doses of lithium, as normally used in lithium clearance studies......1. The effect of a single dose of lithium on renal function before and during intravenous infusion of dopamine (3 micrograms min-1 kg-1) was investigated in 12 healthy males. In a double-blind and randomized design, 450mg or 600mg of lithium carbonate or placebo was administered orally at 22...

  10. Lithium clearance method and the renal response to low-dose dopamine in man

    DEFF Research Database (Denmark)

    Olsen, Niels Vidiendal; Olsen, M H; Fogh-Andersen, N

    1993-01-01

    .00 hours on three different occasions. After an overnight fast, the subjects were water-loaded and clearance studies were started at 09.00 hours with a 1h baseline period and three 1h periods during dopamine infusion. 2. Baseline sodium clearance with placebo was 0.65 +/- 0.35 ml/min, but with lithium...... in effective renal plasma flow, glomerular filtration rate or osmolal clearance. Neither lithium nor dopamine influenced plasma concentrations of renin, aldosterone or atrial natriuretic peptide. 4. In conclusion, single test doses of lithium, as normally used in lithium clearance studies, increase baseline......1. The effect of a single dose of lithium on renal function before and during intravenous infusion of dopamine (3 micrograms min-1 kg-1) was investigated in 12 healthy males. In a double-blind and randomized design, 450mg or 600mg of lithium carbonate or placebo was administered orally at 22...

  11. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    Science.gov (United States)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  12. Radioactive clearance discharge of effluent from nuclear and radiation facilities

    International Nuclear Information System (INIS)

    Liu Xinhua; Xu Chunyan

    2013-01-01

    On the basis of the basic concepts of radiation safety management system exemption, exclusion and clearance, we expound that the general industrial gaseous and liquid effluent discharges are exempted or excluded, gaseous and liquid effluent discharged from nuclear and radiation facilities are clearance, and non-radioactive. The main purpose of this paper is to clarify the concepts, reach a consensus that the gaseous and liquid effluent discharged from nuclear and radiation facilities are non-radioactive and have no hazard to human health and natural environment. (authors)

  13. Effects and outcome of Tamsulosin more than just stone clearance after extracorporeal shock wave lithotripsy for renal calculi

    International Nuclear Information System (INIS)

    Qadri, S. S. U.; Khalid, S. E.; Mahmud, S. M.

    2014-01-01

    Objective: To determine the effect of Tamsulosin, as adjunctive medical therapy after Extracorporeal Shock Wave Lithotripsy for renal stones on rate of stone clearance, clearance time, pain intensity during stone clearance, steinstrasse formation and auxiliary surgical intervention required. Method: A prospective randomized controlled study was carried out in 120 patients who underwent ESWL for renal stones of 0.5-2.0 cm. They were randomized into study and control group in which Tamsulosin 0.4mg/day was given in former as an adjunctive medical therapy. All patients underwent ESWL every 2 weeks until complete stone clearance for 8 weeks. The parameters assessed were stone clearance, clearance time, pain intensity and effect on steinstrasse. Results: Of the 120 patients 60 were in each group. The stone clearance rate was greater in study than in control group, 58(96.7%) vs. 48(80%) respectively, (p<0.004). The mean stone clearance time was observed earlier in study group as compared to control group with significant statistical difference in stone size between 0.6-1.5 cm. The mean intensity of pain patients experienced according to Visual analogue scale (VAS) was significantly less in study group (p<0.002). The rate of steinstrasse formation was observed to be higher in control than in study group 15(25%) vs 6(10%) respectively(p<0.003), while its spontaneous clearance was higher in study group than in control group 83.3% vs 33.3% (p<0.03). Conclusion: Tamsulosin significantly increases stone clearance after shock wave lithotripsy for renal stones. It also appeared to facilitate earlier stone clearance, reduces severity of pain, reduces the incidence of steinstrasse formation and tends to facilitate its spontaneous clearance. (author)

  14. Development of a Novel System to Measure a Clearance of a Passenger Platform

    Science.gov (United States)

    Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.

    2016-06-01

    Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.

  15. Effects of a Nonuniform Tip Clearance Profile on the Performance and Flow Field in a Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    Yohan Jung

    2012-01-01

    Full Text Available This paper presents a numerical investigation of the effects of a nonuniform tip clearance profile on the performance and flow field in a centrifugal compressor with a vaneless diffuser. This study focuses in particular on the magnitude and location of the wake. Six impellers with different tip clearance profiles were tested in the flow simulations. The accuracy of the numerical simulations was assessed by comparing the experimental data with the computational results for a system characterized by the original tip clearance. Although the performance improved for low tip clearances, a low tip clearance at the trailing edge improved the compressor performance more significantly than a low tip clearance at the leading edge. The flow field calculated for a system characterized by a low tip clearance at the trailing edge produced a more uniform velocity distribution both in the circumferential and in the axial directions at the impeller exit because the wake magnitude was reduced. As a consequence, this impeller provided a better potential for diffusion processes inside a vaneless diffuser.

  16. 78 FR 69643 - Proposed Information Collection; Comment Request; Generic Clearance for Customer Satisfaction...

    Science.gov (United States)

    2013-11-20

    ... Clearance for Customer Satisfaction Research AGENCY: U.S. Census Bureau, Commerce. ACTION: Notice. SUMMARY... requesting an extension of the generic clearance to conduct customer satisfaction research which may be in... feedback from its various customer satisfaction research efforts. Each research design is reviewed for...

  17. 76 FR 63301 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-10-12

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  18. 76 FR 15027 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-18

    ... clustering), the precision requirements or power calculations that justify the proposed sample size, the...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  19. Railway clearance intrusion detection method with binocular stereo vision

    Science.gov (United States)

    Zhou, Xingfang; Guo, Baoqing; Wei, Wei

    2018-03-01

    In the stage of railway construction and operation, objects intruding railway clearance greatly threaten the safety of railway operation. Real-time intrusion detection is of great importance. For the shortcomings of depth insensitive and shadow interference of single image method, an intrusion detection method with binocular stereo vision is proposed to reconstruct the 3D scene for locating the objects and judging clearance intrusion. The binocular cameras are calibrated with Zhang Zhengyou's method. In order to improve the 3D reconstruction speed, a suspicious region is firstly determined by background difference method of a single camera's image sequences. The image rectification, stereo matching and 3D reconstruction process are only executed when there is a suspicious region. A transformation matrix from Camera Coordinate System(CCS) to Track Coordinate System(TCS) is computed with gauge constant and used to transfer the 3D point clouds into the TCS, then the 3D point clouds are used to calculate the object position and intrusion in TCS. The experiments in railway scene show that the position precision is better than 10mm. It is an effective way for clearance intrusion detection and can satisfy the requirement of railway application.

  20. Losses and blade tip clearance for a centrifugal compressor

    Directory of Open Access Journals (Sweden)

    Oana DUMITRESCU

    2018-06-01

    Full Text Available The present paper presents the numerical analysis for a transonic centrifugal compressor using steady state CFD. The blade tip clearance effect over the position of shock waves, tip losses and the performances of the impeller are studied. Numerical simulations have been performed using RANS modelling, with the k-omega SST turbulence model (Shear Stress Transport. Eight cases were taken into consideration for the impeller with the following blade tip clearances values: 0 mm, 0.1 mm, 0.3 mm, 0.4 mm, 0.5mm, 0.7 mm, 1 mm, 2 mm, at the same operating conditions. For the entire stage only seven cases were studied, without the value for 0.1 mm because of its abnormal behaviour, as can be seen in the case of the impeller simulations. Results showed that the position of the shock wave does not change with the increase of the tip clearance. Aerodynamic losses due to shock wave, secondary flow and turbulence can be seen in the polytropic efficiency of the centrifugal impeller and the difference between the two extreme cases is about 3.2 %.

  1. The provision of clearances accuracy in piston - cylinder mating

    Science.gov (United States)

    Glukhov, V. I.; Shalay, V. V.

    2017-08-01

    The paper is aimed at increasing the quality of the pumping equipment in oil and gas industry. The main purpose of the study is to stabilize maximum values of productivity and durability of the pumping equipment based on the selective assembly of the cylinder-piston kinematic mating by optimization criterion. It is shown that the minimum clearance in the piston-cylinder mating is formed by maximum material dimensions. It is proved that maximum material dimensions are characterized by their own laws of distribution within the tolerance limits for the diameters of the cylinder internal mirror and the outer cylindrical surface of the piston. At that, their dispersion zones should be divided into size groups with a group tolerance equal to half the tolerance for the minimum clearance. The techniques for measuring the material dimensions - the smallest cylinder diameter and the largest piston diameter according to the envelope condition - are developed for sorting them into size groups. Reliable control of the dimensions precision ensures optimal minimum clearances of the piston-cylinder mating in all the size groups of the pumping equipment, necessary for increasing the equipment productivity and durability during the production, operation and repair processes.

  2. Brain-wide pathway for waste clearance captured by contrast-enhanced MRI.

    Science.gov (United States)

    Iliff, Jeffrey J; Lee, Hedok; Yu, Mei; Feng, Tian; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2013-03-01

    The glymphatic system is a recently defined brain-wide paravascular pathway for cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange that facilitates efficient clearance of solutes and waste from the brain. CSF enters the brain along para-arterial channels to exchange with ISF, which is in turn cleared from the brain along para-venous pathways. Because soluble amyloid β clearance depends on glymphatic pathway function, we proposed that failure of this clearance system contributes to amyloid plaque deposition and Alzheimer's disease progression. Here we provide proof of concept that glymphatic pathway function can be measured using a clinically relevant imaging technique. Dynamic contrast-enhanced MRI was used to visualize CSF-ISF exchange across the rat brain following intrathecal paramagnetic contrast agent administration. Key features of glymphatic pathway function were confirmed, including visualization of para-arterial CSF influx and molecular size-dependent CSF-ISF exchange. Whole-brain imaging allowed the identification of two key influx nodes at the pituitary and pineal gland recesses, while dynamic MRI permitted the definition of simple kinetic parameters to characterize glymphatic CSF-ISF exchange and solute clearance from the brain. We propose that this MRI approach may provide the basis for a wholly new strategy to evaluate Alzheimer's disease susceptibility and progression in the live human brain.

  3. Residual kidney function after donor nephrectomy. Assessment by 99mTc-MAG3-Clearance

    International Nuclear Information System (INIS)

    Hamscho, N.; Doebert, N.; Menzel, C.; Berner, U.; Zaplatnikov, K.; Gruenwald, F.; Wilhelm, A.; Gossmann, J.; Scheuermann, E.H.

    2005-01-01

    Aim: We evaluated the long-term residual renal function after donor nephrectomy using 99m Tc-mercaptoacetyltriglycin (MAG3)-clearance. Donors, methods: Altogether 49 kidney donors were examined using 99m Tc-MAG3-clearance after nephrectomy for donation to a relative (m:f=11.38; age 55±27 years). The donors were examined 16±8 years postoperatively (1.5-26 years). 42 donors (86%) showed normal creatinine values, whereas the other seven (14%) exhibited slightly elevated levels. 20 donors were examined pre- and postoperatively and compared intraindividually. The kidney function was compared to the age adapted normal values of healthy persons with two kidneys (67-133% of age related mean). Results: After nephrectomy all donors showed a normal perfusion, good secretion, merely physiological intrarenal transit and a normal elimination from the kidneys. The 99m Tc-MAG3-clearance was 69±15% of the normal mean value of healthy carriers of two kidneys regardless of the gender. 20 donors with a preoperative examination showed a significantly reduced total renal function from 84±15% of the mean normal value preoperatively to 60±15% postoperatively (p 99m Tc-MAG3-clearance measured prior to nephrectomy and the clearance levels after nephrectomy. Also, no correlation between the preoperative 99m Tc-MAG3-clearance and the postoperative serum creatinine values could be observed. Althogether, 22% of the donors (11/49) developed arterial hypertension 10±8 years after donation (1-23 years). This corresponds to the normal age prevalence of hypertension in the carriers of two kidneys. Three donors suffered from arterial hypertension prior to the operation. Conclusion: Kidney donors with normal or slightly elevated creatinine values postoperatively show a 99m Tc-MAG3 clearance value of 69% of the mean value of healthy carriers of two kidneys. This may serve as a reference value for healthy carriers of one kidney. In our study we demonstrated a good compensation of the contralateral

  4. Analysis of hepatitis B virus intrahepatic covalently closed circular DNA and serum viral markers in treatment-naive patients with acute and chronic HBV infection.

    Directory of Open Access Journals (Sweden)

    Weijie Li

    Full Text Available BACKGROUND: This study aimed to investigate the relationships of intrahepatic cccDNA with serum HBsAg and with HBV DNA in treatment-naive patients throughout acute and chronic HBV infection. METHODS: A total of 120 patients who had a liver biopsy were enrolled, including 19 with acute hepatitis B (AHB, and 101 patients with chronic HBV infection (CHB of whom were 10 in immune-tolerant (IT phase, 59 in immune-clearance (IC phase, 8 in low-replicative (LR phase, and 24 in HBeAg-negative hepatitis (ENH phase. Intrahepatic cccDNA, serum HBsAg and serum HBV DNA levels were comparatively analyzed. RESULTS: The median intrahepatic cccDNA levels were 0.18 4.80, 3.81, 0.22 and 0.97 copies/cell for patients with AHB, CHB-IT, CHB-IC, CHB-LR, and CHB-ENH, respectively. In AHB patients, intrahepatic cccDNA was positively correlated with serum HBsAg (r = 0.665, P = 0.003, as well as serum HBV DNA (r = 0.536, P = 0.022. In CHB patients, intrahepatic cccDNA was positively correlated with serum HBsAg in the IC phase (r = 0.392, P = 0.005, and with serum HBV DNA in the IC phase (r = 0.301, P = 0.036 and ENH phase (r = 0.588, P = 0.013. HBV replicative efficiency, defined as the ratio of serum HBV DNA to intrahepatic cccDNA, was obviously lower in AHB and CHB-LR patients than in CHB-IT, CHB-IC and CHB-ENH patients (0.70 and 0.53 vs. 1.12, 1.09 and 0.99, P<0.001, values were logarithmic transformed for analysis. In CHB-IC patients, HBV replicative efficiency was positively correlated with histological activity index of liver inflammation (r = 0.308, P = 0.009. CONCLUSION: Serum HBsAg and HBV DNA levels may reflect the amount of active intrahepatic cccDNA in treatment-naive AHB and CHB-IC patients. Reduced intrahepatic cccDNA and HBV replicative efficiency may imply effective immune control of HBV infection.

  5. Demonstration of a dynamic clearance seal in a rotating test facility.

    OpenAIRE

    Messenger, Andrew; Williams, Richard; Ingram, Grant; Hogg, Simon; Tibos, Stacie; Seaton, Jon; Charnley, Bernard

    2017-01-01

    The successful demonstration of the “Aerostatic Seal” in a half scale rotating facility is described in this paper. The Aerostatic seal is a novel dynamic clearance seal specifically designed for steam turbine secondary gas path applications. The seal responds to radial rotor excursions, so a reduced clearance can be maintained compared to conventional labyrinth seal without damage to the seal. This enables increased turbine performance through reduced leakage and increased tolerance of turbi...

  6. Intra-operative colloid administration increases the clearance of a post-operative fluid load

    DEFF Research Database (Denmark)

    Borup, Tine; Hahn, Robert; Holte, K

    2009-01-01

    using volume kinetics based on the plasma dilution alone. The pre-operative plasma clearance was compared with the post-operative plasma clearance and patients served as their own control. RESULTS: The urinary excretion averaged 350 ml for the pre-operative infusion and 612 ml post-operatively, which...

  7. 76 FR 20967 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-14

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  8. Clearance rate of Mytilus edulis (L.) as a function of current velocity and mussel aggregation

    DEFF Research Database (Denmark)

    Nielsen, Pernille; Vismann, Bent

    2014-01-01

    by current velocities up to 1.4 m/sec, whereas experiments with 3 mussels showed that clearance of the mussels decreased progressively at current velocities greater than 0.2 m/sec, and reached 0 L/h per individual at current velocities greater than 0.6 m/sec. The constant feeding at all current velocities......The aim of the current study was to investigate the effect of water current velocities on the clearance rate of Mytilus edulis when different numbers of mussels were used in the experiments. An automatic setup, which controlled and monitored the algal concentration continually, was used to measure...... the effect of increasing current velocity (0.05-1.4 m/sec) on the M. edulis clearance rate. Clearance rate measurements were performed under constant food concentrations of 3,000 cells/mL of Rhodomonas salina on either 3 mussels or 20 mussels. We found that the clearance rate of 20 mussels was unaffected...

  9. Effect of increased surface hydrophobicity via drug conjugation on the clearance of inhaled PEGylated polylysine dendrimers.

    Science.gov (United States)

    Haque, Shadabul; McLeod, Victoria M; Jones, Seth; Fung, Sandy; Whittaker, Michael; McIntosh, Michelle; Pouton, Colin; Owen, David J; Porter, Christopher J H; Kaminskas, Lisa M

    2017-10-01

    PEGylated polylysine dendrimers are attractive and well tolerated inhalable drug delivery platforms that have the potential to control the release, absorption kinetics and lung retention time of conjugated drugs. The clinical application of these systems though, would likely require partial substitution of surface PEG groups with drug molecules that are anticipated to alter their lung clearance kinetics and clearance pathways. In the current study, we therefore evaluated the impact of increased surface hydrophobicity via substitution of 50% surface PEG groups with a model hydrophobic drug (α-carboxyl OtButylated methotrexate) on the lung clearance of a Generation 5 PEGylated polylysine dendrimer in rats. PEG substitution with OtBu-methotrexate accelerated lung clearance of the dendrimer by increasing polylysine scaffold catabolism, improving systemic absorption of the intact dendrimer and low molecular weight products of scaffold catabolism, and enhancing mucociliary clearance. These results suggest that the conjugation of hydrophobic drug on the surface of a PEGylated dendrimer is likely to accelerate lung clearance when compared to a fully PEGylated dendrimer. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  10. Using radioaerosols to monitor physiotherapy-enhanced mucus clearance at different levels of the bronchial tree

    International Nuclear Information System (INIS)

    Hasani, A.; Pavia, D.; Clarke, S.W.; Agnew, J.E.

    1993-01-01

    Patients with airways obstruction often find it difficult to clear excess lung secretions. Frequent coughing can clear the larger airways but may itself further damage the airways ciliated epithelium. Various physiotherapy regimes have been proposed yet objective evidence of their efficacy is sparse. Deposited aerosol particles - with an appropriate label for gamma imaging - can track clearance from different lung regions. Published reports have however tended to be equivocal in respect of clearance from the more distal conducting airways. Questions also arise as to coordination of transport rates at different levels of the bronchial tree. We therefore sought to re-assess requirements for effective analysis of physiotherapy-enhanced clearance to yield data on both peripheral and central airways clearance. (author)

  11. Using radioaerosols to monitor physiotherapy-enhanced mucus clearance at different levels of the bronchial tree

    Energy Technology Data Exchange (ETDEWEB)

    Hasani, A.; Pavia, D.; Clarke, S.W.; Agnew, J.E. (Royal Free Hospital, London (United Kingdom))

    1993-01-01

    Patients with airways obstruction often find it difficult to clear excess lung secretions. Frequent coughing can clear the larger airways but may itself further damage the airways ciliated epithelium. Various physiotherapy regimes have been proposed yet objective evidence of their efficacy is sparse. Deposited aerosol particles - with an appropriate label for gamma imaging - can track clearance from different lung regions. Published reports have however tended to be equivocal in respect of clearance from the more distal conducting airways. Questions also arise as to coordination of transport rates at different levels of the bronchial tree. We therefore sought to re-assess requirements for effective analysis of physiotherapy-enhanced clearance to yield data on both peripheral and central airways clearance. (author).

  12. Binding and clearance of Tc-99m pyrophosphate from the lungs of smokers and nonsmokers

    International Nuclear Information System (INIS)

    Isitman, A.T.; Effros, R.; Collier, B.D.; Palmer, D.W.; Krasnow, A.Z.; Hellman, R.S.; Hacker, A.; Berger, C.; Trembath, L.

    1990-01-01

    Both acute and chronic lung disorders that affect the alveolar epithelium increase the rate at which aerosolized Tc-99 m DTPA is cleared from the lungs. Transalveolar clearance of Tc-99 DTPA has been used to detect lung injury, but- because smokers have a much faster clearance rate of Tc-99m DTPA-this examination has been limited primarily to nonsmokers. The purpose of this paper is to determine if the clearance of a larger molecule, Tc-99m PYP (molecular weight by ultrafiltration between 1.000 and 3,000 daltons), is also accelerated by smoking. Clearances of each indicator were studies for 6 hours in eight normal nonsmoking subjects and seven (otherwise normal smokers)

  13. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    Science.gov (United States)

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 hours and then daily in 484 patients. AKI was defined either as > 50% increase in plasma creatinine from baseline, or > 33.3% decrease in creatinine clearance. The diagnostic and predictive performance of the two AKI definitions were compared. Results Creatinine clearance decrease diagnosed AKI in 24% of those not diagnosed by plasma creatinine increase on entry. These patients entered the ICU sooner after insult than those diagnosed with AKI by plasma creatinine elevation (P = 0.0041). Mortality and dialysis requirement increased with the change in creatinine clearance-acute kidney injury severity class (P = 0.0021). Amongst patients with plasma creatinine creatinine clearance improved the prediction of AKI considerably (Net Reclassification Improvement 83%, Integrated Discrimination Improvement 0.29). On-entry, creatinine clearance associated with AKI severity and duration (P 33.3% decrease in creatinine clearance over the first 12 hours was associated with a 2.0-fold increased relative risk of dialysis or death. Conclusions Repeated 4-hour creatinine clearance measurements in critically ill patients allow earlier detection of AKI, as well as progression and recovery compared to plasma creatinine. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN012606000032550. PMID:22713519

  14. Identification of Clearance and Contact Stiffness in a Simplified Barrel-Cradle Structure of Artillery System

    Directory of Open Access Journals (Sweden)

    Bing Li

    2015-02-01

    Full Text Available In gun barrel-cradle structure, the presence of clearance usually changes the dynamic response of muzzle and results in shooting dispersion (under continuous firing condition. The parameter estimation of such clearance nonlinear system is the prerequisite for establishing quantitative relation between the clearance and muzzle disturbance. In this paper, the restoring force surface (RFS method and the nonlinear identification through feedback of outputs (NIFO method are first combined for parameter identification in a simplified barrel-cradle structure. With the RFS method, clearance value can be obtained by analyzing the restoring force plot. Then the contact stiffness can be identified by using NIFO method. This identification process is verified in a single-degree-of-freedom (SDOF system with clearance. To adapt to the rigid-flexible coupled beam system with clearances which is simplified from the barrel-cradle structure, a modification for the combined method mentioned above is proposed. The core idea of the modification is reducing the continuous system to multiple-degree-of-freedom (MDOF system to reserve the nonlinear characteristics through modal transformation matrix. The advantage of this transformation is that the linear parts of the MDOF systems are decoupled, which greatly reduces the difficulty of identification. The simulation results have shown the effectiveness of current method.

  15. Comparative study of conventional PAH and inulin clearance and slope clearance of 131I-o-hippuric acid and 51Cr-EDTA

    International Nuclear Information System (INIS)

    Berghaeuser, H.

    1981-01-01

    ''Classic'' PAH and inulin clearance were determined in 81 patients with renal anomalies or renal diseases of different genesis and severity. In addition, radioisotope nephrography was carried out after administration of I-131-o-hippuric acid, followed by administration of Cr-51-EDTA. The activity decrease was recorded by a sensor located over the patient's right shoulder; the activities of a serum sample and of the urine excreted after 21 or 31 min were measured, and the findings were compared with those of the classic method. The clearance data calculated on the basis of the soulder measurements were hardly compatible with those of the conventional method in the case of 131 I-o-hippuric acid (r=0.54) and totally incompatible in the case of 51 Cr-EDTA. This means that the method described by Oberhausen is the only accurate method available for a quantitative assessment of the renal function on the basis of measurements of the activity decrease in the body. The activity of urine excreted after 31 min ( 131 I-hippuric acid:r=0.992, 51 Cr-EDTA:r=0.79) is a sufficiently accurate parameter although it is inaccurate at PAH clearance, values > 130 ml/min and inulin clearance values > 30 ml/min. Of the many parameters of radioisotope nephrogram curves, in the case of 131 I-o-hippuric acid only the parameters related to the ascent between 48 and 120 sec or to the secant ascent yield sufficient quantitative information for certain functional regions (r=0.9 resp. r=0.93). In the case of 51 Cr-EDTA, semiquantitative information on the renal function can be obtained by constructing secants on the nephrogram curves (r=0.7 resp. r=0.72). Here as in the case of 131 I-hippuric acid, the contribution of each kidney can be determined individually from the functional analysis of both kidneys. (orig.) [de

  16. Control of internal packing seal clearances considering for shaft behavior during steam turbine operation

    Energy Technology Data Exchange (ETDEWEB)

    Pack, Min Sik; Lee, Si Yeon; Choi, Sung Choul; Lee, Jae Geun [Korea Plant Service and Engineering Co., Ltd., Seongnam (Korea, Republic of); Yang, Bo Suk [Pukyong National Univ., Busan (Korea, Republic of)

    2004-07-01

    This paper presents the characteristics of internal clearances for the interstage of blades and shaft gland seals on the steam turbine which are installed in tandem compound. Internal clearances was changed when the rotor turned in the cylindrical sleeve bearing due to the generation of oil film wedge. This presented concern is very useful to prevent the rubbing damage of seal edge between the fixed and moving parts in steam turbine due to the misalignment at the rotating and stationary parts. This method is applied for the unbalanced clearances distribution to the left and right sides in the turbine casing. A considerable amount of unbalanced clearances distribution trend is determined according to the rotating speed of rotor, size and type of journal bearing, oil viscosity, surface roughness of bearing and shaft, oil temperature, oil pressure and bearing load.

  17. Effects of cigarette smoking on I-123 IMP clearance from the lung

    International Nuclear Information System (INIS)

    Katoh, Kunihiko; Takahashi, Tsuneo

    1990-01-01

    N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP), originally developed as a brain scanning agent, is also taken up by the lung. To evaluate the cigarette smoking on the uptake of IMP by the lung, we studied I-123 IMP clearance from the lung on 14 volunteers; 5 non-smokers and 9 smokers. After the injection of 111 MBq (3mCi) of I-123 IMP into the medial cubital vein, the time-activity curve for 60 minutes and the regional activity using 1 frame per minute and a 64 x 64 matrix was obtained. I-123 IMP clearance curve was described as follows: C(t)=A 1 e -k1t +A 2 e -k2t (A 1 , A 2 : intercepts, and k 1 , k 2 : slopes of the exponential components). I-123 IMP clearance was delayed in smokers, and k 2 was smaller in smokers. Also a significant correlations between k 1 , k 2 , and the number of cigarettes smoked per day were found. In conclusion, this study suggests that the delayed clearance and retention of I-123 IMP in the lung indicate the lung metabolic disorders due to cigarette smoking. (author)

  18. Effect of Guide Vane Clearance Gap on Francis Turbine Performance

    Directory of Open Access Journals (Sweden)

    Ravi Koirala

    2016-04-01

    Full Text Available Francis turbine guide vanes have pivoted support with external control mechanism, for conversion of pressure to kinetic energy and to direct them to runner vanes. This movement along the support is dependent on variation of load and flow (operating conditions. Small clearance gaps between facing plates and the upper and lower guide vane tips are available to aid this movement, through which leakage flow occurs. This secondary flow disturbs the main flow stream, resulting performance loss. Additionally, these increased horseshoe vortex, in presence of sand, when crosses through the gaps, both the surfaces are eroded. This causes further serious effect on performance and structural property by increasing gaps. This paper discusses the observation of the severity in hydropower plants and effect of clearance gaps on general performance of the Francis turbine through computational methods. It also relates the primary result with the empirical relation for leakage flow prediction. Additionally, a possible method to computationally estimate thickness depletion has also been presented. With increasing clearance gap, leakage increases, which lowers energy conversion and turbine efficiency along with larger secondary vortex.

  19. Impairment of aminopyrine clearance in aspirin-damaged canine gastric mucosa

    International Nuclear Information System (INIS)

    Miller, T.A.; Henagan, J.M.; Loy, T.M.

    1983-01-01

    Using an in vivo canine chambered stomach preparation, the clearance of [ 14 C]aminopyrine across mucosa when intravenously infused and the back-diffusion of this substance from gastric lumen to mucosa when topically applied to gastric epithelium were evaluated in aspirin-damaged gastric epithelium. In mucosa damaged by either 20 mM or 40 mM aspirin, the recovery of [ 14 C]aminopyrine, when topically mixed with acid (pH . 1.1) perfusate solution, was not significantly different from nondamaged control mucosa. In addition, the degree of ''trapping'' of this substance from back-diffusion was not different in damaged mucosa from that observed in nondamaged epithelium. In contrast, when [ 14 C]aminopyrine was intravenously infused, its clearance was significantly impaired in aspirin-damaged mucosa when compared with control studies, as evidenced by the increased ''trapping'' of this substance in injured epithelium. These findings indicate that movement of aminopyrine from plasma to gastric lumen is impaired in damaged epithelium, making the aminopyrine clearance technique an unreliable method to accurately measure absolute gastric blood flow in this experimental setting

  20. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  1. 14 CFR 99.17 - Deviation from flight plans and ATC clearances and instructions.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Deviation from flight plans and ATC clearances and instructions. 99.17 Section 99.17 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... TRAFFIC General § 99.17 Deviation from flight plans and ATC clearances and instructions. (a) No pilot may...

  2. Frequency of stone clearance after extracorporeal shockwave ...

    African Journals Online (AJOL)

    Objective: To determine the rate of stone clearance after extracorporeal shockwave lithotripsy (ESWL) for renal stones in adult patients with renal insufficiency. Subjects and methods: This is a cross-sectional descriptive study of 117 adult patients who underwent ESWL. The indications for ESWL were determined by the ...

  3. Correlates of spontaneous clearance of hepatitis C virus in a Danish human immunodeficiency virus type 1 cohort

    DEFF Research Database (Denmark)

    Clausen, Louise Nygaard; Weis, Nina; Schønning, Kristian

    2011-01-01

    ) 18-28) had cleared their HCV infection and 251 (77%; 95% CI 72-82) had a chronic infection. The clearance rate in HBsAg-positive individuals was 65%. Being female, HBsAg-positive, or belonging to HIV exposure groups IDU and MSM predicted higher HCV clearance rates (adjusted odds ratio (aOR) 1.8, 95......% CI 1-3.2; aOR 7.6, 95% CI 2.7-21; aOR 5.2, 1.2-23.5; and aOR 10.2, 95% CI 1.8-58, respectively). Race, acquired immunodeficiency syndrome (AIDS), and antiretroviral therapy were not associated with HCV clearance. Conclusions: The HCV clearance rate in this HIV-1 cohort was 23%. MSM and IDUs may have......Abstract Background: Around a quarter of individuals infected with hepatitis C virus (HCV) are spontaneously able to clear the virus. Correlates of spontaneous HCV clearance are not well established and the aim of this study was to characterize factors associated with spontaneous HCV clearance...

  4. A model of metabolism and clearance of organic compounds from the respiratory tract

    International Nuclear Information System (INIS)

    Gerde, P.; Dahl, A.R.

    1994-01-01

    In cases where inhalants induce toxicity in the airway epithelium, the mechanism of absorption is an important determinant of target dose. Absorption of organic solutes in the lungs occurs mainly by two consecutive mechanisms; molecular diffusion drives the chemicals into the tissues, and blood perfusion of the tissues removes the chemicals into the systemic circulation. Solutes having lipophilicities ranging from equally soluble in lipids and water to moderately more lipid-soluble are limited by the perfusion during clearance from the lungs. The perfusion-limited solute enters the blood circulation from all regions of the lungs within minutes and is distributed to other organs via the systemic circulation. In contrast, clearance of highly lipophilic toxicants, such as benzo(a)pyrene, from the lungs is diffusion-limited. The limiting process refers to the slowest transport mechanism of either perfusion or diffusion. Because of the short distance from the surface of the alveolar region to the capillary network, diffusion-limited clearance of highly lipophilic solutes occurs within minutes. In the thicker epithelium of the conducting airways, however, clearance may take hours. The purpose of the current modeling effort was to encompass both mechanisms of clearance in a single model in order to explore the influence of toxicant lipophilicity and local metabolism on the dosimetry at the airway portal-of-entry

  5. Hepatic and muscle clearance of physostigmine in the rat after i.v. administration

    International Nuclear Information System (INIS)

    Somani, S.M.; Unni, L.K.

    1986-01-01

    This study presents a method to calculate the extraction ratio (ER) from in vivo time course of liver metabolism using the physiological and pharmacokinetic parameters such as plasma flow rate, partition coefficient of drug between tissue and plasma and the elimination rate constant from tissues. Rats were administered 3 H-physostigmine (Phy), 100 μg/kg i.v.; and were sacrificed at various times. Tissues were removed and Phy and its metabolites were determined by HPLC. Half-life of Phy in liver and muscle was 24 and 20 min, respectively. ER of Phy in liver was .71 which showed a slight decrease at 10 min. Muscle ER was found to be .347 up to 5 min. Hepatic clearance was calculated to be 23.08 ml/min/kg (34.9% of systemic clearance) and the intrinsic clearance was 83.73 ml/min/kg which indicates that the changes in blood flow to the liver can cause a variation in the systematic clearance. Percentage dose of Phy retained in muscle was maximum and the clearance was 5.2 ml/min/kg suggesting that muscle might be acting as a storage depot for Phy prolonging the pharmacological effects. About 30-40% of radioactivity in the liver could not be washed off by 10% TCA or organic solvents indicating the irreversible binding of drug or metabolite to liver macromolecule

  6. Quantitative static scintigraphy for the evaluation of mucociliary clearance

    International Nuclear Information System (INIS)

    Maini, C.L.; Marchetti, L.; Giordano, A.; Antonelli Incalzi, R.; Fuso, L.

    1988-01-01

    Mucociliary clearance can be evaluated by radionuclide techniques, but such approaches have been usually implemented only in research-oriented laboratories because of technical difficulties. A very practical radionuclide method is here presented which requires only three static acquisitions after the inhalation of a polydisperse radioaerosol produced by a commercial generator. Data processing is also very simple. The diagnostic performance of the method was tested on a study population of 10 healthy subjects and 10 patients with athrophic bronchitis; a higly significance difference between normal and pathological patients was found. Its simple implementation and diagnostic yield recommend this radionuclide method for the routine assessment of mucociliary clearance also in busy clinical-oriented laboratories

  7. Sulfadoxine-pyrimethamine monotherapy in Tanzanian children gives rapid parasite clearance but slow fever clearance that is improved by chloroquine in combination therapy

    DEFF Research Database (Denmark)

    Tarimo, D S; Minjas, J N; Bygbjerg, I C

    2002-01-01

    Following widespread chloroquine (CQ) resistance, sulfadoxine plus pyrimethamine (SP) is now the first line antimalarial drug in a number of African countries including Tanzania. Unlike CQ, SP has no antipyretic effects, a feature that might delay fever clearance, and by acting on late stage para...... on possible delayed parasitological and clinical responses to SP that could result from its action on late stage parasites. Despite its diminishing antimalarial activity, CQ has beneficial in vivo antipyretic effects in therapeutic combination with SP.......Following widespread chloroquine (CQ) resistance, sulfadoxine plus pyrimethamine (SP) is now the first line antimalarial drug in a number of African countries including Tanzania. Unlike CQ, SP has no antipyretic effects, a feature that might delay fever clearance, and by acting on late stage...

  8. Importance of Bacterial Replication and Alveolar Macrophage-Independent Clearance Mechanisms during Early Lung Infection with Streptococcus pneumoniae

    Science.gov (United States)

    Camberlein, Emilie; Cohen, Jonathan M.; José, Ricardo; Hyams, Catherine J.; Callard, Robin; Chimalapati, Suneeta; Yuste, Jose; Edwards, Lindsey A.; Marshall, Helina; van Rooijen, Nico; Noursadeghi, Mahdad

    2015-01-01

    Although the importance of alveolar macrophages for host immunity during early Streptococcus pneumoniae lung infection is well established, the contribution and relative importance of other innate immunity mechanisms and of bacterial factors are less clear. We have used a murine model of S. pneumoniae early lung infection with wild-type, unencapsulated, and para-amino benzoic acid auxotroph mutant TIGR4 strains to assess the effects of inoculum size, bacterial replication, capsule, and alveolar macrophage-dependent and -independent clearance mechanisms on bacterial persistence within the lungs. Alveolar macrophage-dependent and -independent (calculated indirectly) clearance half-lives and bacterial replication doubling times were estimated using a mathematical model. In this model, after infection with a high-dose inoculum of encapsulated S. pneumoniae, alveolar macrophage-independent clearance mechanisms were dominant, with a clearance half-life of 24 min compared to 135 min for alveolar macrophage-dependent clearance. In addition, after a high-dose inoculum, successful lung infection required rapid bacterial replication, with an estimated S. pneumoniae doubling time of 16 min. The capsule had wide effects on early lung clearance mechanisms, with reduced half-lives of 14 min for alveolar macrophage-independent and 31 min for alveolar macrophage-dependent clearance of unencapsulated bacteria. In contrast, with a lower-dose inoculum, the bacterial doubling time increased to 56 min and the S. pneumoniae alveolar macrophage-dependent clearance half-life improved to 42 min and was largely unaffected by the capsule. These data demonstrate the large effects of bacterial factors (inoculum size, the capsule, and rapid replication) and alveolar macrophage-independent clearance mechanisms during early lung infection with S. pneumoniae. PMID:25583525

  9. Clearance rates of jellyfish and their potential predation impact on zooplankton and fish larvae in a neritic ecosystem (Limfjorden, Denmark)

    DEFF Research Database (Denmark)

    Hansson, L. J.; Moeslund, O.; Kiørboe, Thomas

    2005-01-01

    clearance potential were given assumed clearance rate values, but the collective predation potential by these species was evaluated to be small. Hydromedusae dominated numerically and had their highest potential clearance impact in spring, but overall jellyfish clearance potential on copepods was low during...

  10. RENAL CLEARANCE AND URINARY EXCRETION OF CIPROFLOXACIN IN GOATS

    Directory of Open Access Journals (Sweden)

    Z. IQBAL, I. JAVED, B. ASLAM, F. MUHAMMAD AND I. U. JAN

    2007-10-01

    Full Text Available The renal clearance and urinary excretion of ciprofloxacin were investigated in eight healthy female goats. In each animal, ciprofloxacin was administered intramuscularly at the rate of 5 mg/kg body weight. Following drug administration, blood and urine samples were collected at different time intervals and analyzed for ciprofloxacin and creatinine. High performance liquid chromatography (HPLC was used to determine the drug concentration in the plasma and urine. The value of diuresis after single administration of ciprofloxacin was 0.073 ± 0.014 ml/min/kg. Mean (± SE values for renal clearance of creatinine and ciprofloxacin were 1.870 ± 0.385 and 0.982 ± 0.166 ml/min/kg, respectively. The ratio between the renal clearance of ciprofloxacin and that of creatinine remained less than one, which was indicative of back diffusion. The mean (± SE value for the cumulative percent of ciprofloxacin dose excreted at 10 hours following its intramuscular administration was 13.03 ± 2.07. Based on these results, it was evident that besides glomerular filtration, renal handling of drug involved back diffusion also. It was concluded that in local goats glomerular filtration rate (GFR was lower than that reported for their foreign counterparts.

  11. LRP1 in Brain Vascular Smooth Muscle Cells Mediates Local Clearance of Alzheimer's Amyloid-β

    OpenAIRE

    Kanekiyo, Takahisa; Liu, Chia-Chen; Shinohara, Mitsuru; Li, Jie; Bu, Guojun

    2012-01-01

    Impaired clearance of amyloid-β (Aβ) is a major pathogenic event for Alzheimer’s disease (AD). Aβ depositions in brain parenchyma as senile plaques and along cerebrovasculature as cerebral amyloid angiopathy (CAA) are hallmarks of AD. A major pathway that mediates brain Aβ clearance is the cerebrovascular system where Aβ is eliminated through the blood-brain barrier (BBB) and/or degraded by cerebrovascular cells along the interstitial fluid drainage pathway. An Aβ clearance receptor, the low-...

  12. Bronchoscintigraphy and pulmonary clearance of 99mTc-albumin colloid in study of mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, Jann

    1998-01-01

    A radioaerosol based method for measuring MC was introduced. It included an inhalation protocol that resulted in a predominant deposition of radioaerosol in the central bronchi and two simple procedures of evaluation: 1) a visual semi-quantitative bronchoscintigraphic analysis, and 2) a quantitative analysis of the retention of the radioactivity at different points after the inhalation. The results showed that bronchoscintigraphy was a simple technique that may be used to visualize a stimulation of mucociliary transport in the central airways of individuals that do not suffer from too much mucus hypersecretion. Comparison of the MC between individuals, however, should preferably be performed by the method of quantitative analysis of the radioactivity disappearance. A change of MC was found to be one of the first detectable effects on lung function of tobacco smoking. It could be effectively detected by measurement of radioaerosol clearance both by bronchoscintigraphy and simple quantification of the MC. The MC may be either acutely enhanced, reduced or not changed by smoking. Long-term smoking impairs MC. The enhancement of MC by β 2 -agonists was very limited in most patients with CF. In the hope of increasing mucus transport in patients with CF, these are treated with various chest physiotherapy techniques. The radioaerosol based method of measurement of MC could assess mucus clearance by chest physiotherapy and cough. (au)

  13. Tip Clearance Control Using Plasma Actuators

    Science.gov (United States)

    2007-03-01

    Clearance Control Using Plasma Actuators 4 posed by Denton (1993). A number of investigators have used partial shrouds, or " winglet " designs to...SDBD actuator Plasma enhanced aerodynamics has been demonstrated in a range of applications involving sepa- ration control, lift enhancement, drag... aerodynamic benefits of a squealer tip geometry. Specifically, the squealer tip is known to reduce the discharge coefficient of the tip gap, thereby

  14. U.S. nuclear fuel cycle regulatory issues on exclusion, exemption, and clearance

    International Nuclear Information System (INIS)

    Meck, R.A.

    1997-01-01

    The U.S. Nuclear Regulatory Commission is considering the use of exclusion and clearance in connection with the nuclear fuel cycle regulations. Clearance of licensed lands, buildings, structures, materials, and equipment could expose members of the public to radiation in addition to background. Establishing and implementing dose criteria for allowed concentrations of radioactivity in the various media raise challenging issues for the regulator. Clearance also raises significant regulatory issues, and these issues reflect trade-offs between concerns for protecting public health and safety, as well as other socioeconomic values and concerns. At the heart of the issues are the adequacy of risk analyses, acceptability of risks, underlying rationales, feasibility and cost of implementation, and exposures of the public to man-made radiation in relation to natural sources of radiation. (author)

  15. 76 FR 13020 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Science.gov (United States)

    2011-03-09

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  16. Assessments of risk following the inhalation of plutonium oxide using observed lung clearance patterns

    International Nuclear Information System (INIS)

    Ramsden, D.

    1977-10-01

    Dose commitments and risk estimates for the inhalation of plutonium oxide are calculated using the lung clearance patterns observed at AEE Winfrith. These risks are compared with published data on risks arising from a lung clearance based on the ICRP Lung Model. (author)

  17. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample

    DEFF Research Database (Denmark)

    Kamper, A L; Nielsen, S L

    1989-01-01

    Two hundred and thirty-four measurements of standard 51Cr-EDTA plasma clearance were made in 50 patients with severe chronic renal failure. Based on these data two calculation methods were attempted using one plasma sample drawn 24 h after injection of 51Cr-EDTA. One of the methods used the 'one...... at zero-time was derived from injected dose and body surface area. This method might provide values 1.5 ml/min below or 0.8 ml/min above the established method of 51Cr-EDTA plasma clearance, which would be acceptable for clinical purposes. It is concluded that exact plasma clearance of 51Cr-EDTA in severe...... renal dysfunction (estimated clearance values below 21 ml/min) may be determined with adequate precision by one plasma sample drawn at 24 h after injection of the tracer without sampling at 5 h. This appears to be a very practical simplification....

  18. Ginsenoside compound K promotes β-amyloid peptide clearance in primary astrocytes via autophagy enhancement.

    Science.gov (United States)

    Guo, Jinhui; Chang, Li; Zhang, Xin; Pei, Sujuan; Yu, Meishuang; Gao, Jianlian

    2014-10-01

    The aim of the present study was to investigate the effect of ginsenoside compound K on β-amyloid (Aβ) peptide clearance in primary astrocytes. Aβ degradation in primary astrocytes was determined using an intracellular Aβ clearance assay. Aggregated LC3 in astrocyte cells, which is a marker for the level of autophagy, was detected using laser scanning confocal microscope. The effect of compound K on the mammalian target of rapamycin (mTOR)/autophagy pathway was determined using western blot analysis, and an enzyme-linked immunosorbent assay was used for Aβ detection. The results demonstrated that compound K promoted the clearance of Aβ and enhanced autophagy in primary astrocytes. In addition, it was found that phosphorylation of mTOR was inhibited by compound K, which may have contributed to the enhanced autophagy. In conclusion, compound K promotes Aβ clearance by enhancing autophagy via the mTOR signaling pathway in primary astrocytes.

  19. Oral sugar clearance and root caries prevalence in rheumatic patients with dry mouth symptoms.

    Science.gov (United States)

    Risheim, H; Arneberg, P; Birkhed, D

    1992-01-01

    The relationship between root caries, oral sugar clearance, salivary flow rate, and salivary counts of mutans streptococci, lactobacilli and candida has been studied in a group of 22 rheumatic patients (age range 40-72 years). The study group comprised all subjects volunteering for a clinical trial on relief of dry mouth symptoms. The median salivary flow was 0.09 ml/min at rest and 0.9 ml/min during chewing stimulation. The median sugar clearance time was about 5 min in the sublingual area and 16 min in the lower buccal vestibule. For subjects with 0-2 root caries lesions the clearance time at both sites was shorter than for subjects with 3 or more lesions (p flow, and high salivary counts of mutans streptococci. It is concluded that root caries in rheumatic patients with low salivary flow is significantly related to oral sugar clearance time.

  20. The Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    International Nuclear Information System (INIS)

    Lange, W.; Koehler, H.; Apodaca, J.

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were re-examined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not encountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test. (orig.) [de

  1. Blood lactate clearance after maximal exercise depends on active recovery intensity.

    Science.gov (United States)

    Devlin, J; Paton, B; Poole, L; Sun, W; Ferguson, C; Wilson, J; Kemi, O J

    2014-06-01

    High-intensity exercise is time-limited by onset of fatigue, marked by accumulation of blood lactate. This is accentuated at maximal, all-out exercise that rapidly accumulates high blood lactate. The optimal active recovery intensity for clearing lactate after such maximal, all-out exercise remains unknown. Thus, we studied the intensity-dependence of lactate clearance during active recovery after maximal exercise. We constructed a standardized maximal, all-out treadmill exercise protocol that predictably lead to voluntary exhaustion and blood lactate concentration>10 mM. Next, subjects ran series of all-out bouts that increased blood lactate concentration to 11.5±0.2 mM, followed by recovery exercises ranging 0% (passive)-100% of the lactate threshold. Repeated measurements showed faster lactate clearance during active versus passive recovery (P40%>passive recovery, Pexercise clears accumulated blood lactate faster than passive recovery in an intensity-dependent manner, with maximum clearance occurring at active recovery of 80% of lactate threshold.

  2. Evaluation of aorto-iliac disease with Doppler ultrasound and isotope clearance techniques

    International Nuclear Information System (INIS)

    Appleberg, M.; Lewis, J.D.

    1975-01-01

    The clearance of 99 mTc from the hamstring muscle compartment of patients with aorto-iliac or iliac disease was examined with the patients at rest and after exercise. The values were compared with those obtained in a group of controls and another group with superficial femoral, or femoropopliteal arterial occlusion. A statistically significant difference in the rate of 99 mTc clearance was found in patients with proximal vascular disease

  3. Dual roles for hepatic lectin receptors in the clearance of chilled platelets

    DEFF Research Database (Denmark)

    Rumjantseva, Viktoria; Grewal, Prabhjit K; Wandall, Hans H

    2009-01-01

    -GlcNAc moieties by galactosylation prevents clearance of short-term-cooled platelets, this strategy is ineffective after prolonged refrigeration. We report here that prolonged refrigeration increased the density and concentration of exposed galactose residues on platelets such that hepatocytes, through Ashwell-Morell...... transfusion. Inhibition of chilled platelet clearance by both beta(2) integrin and Ashwell-Morell receptors may afford a potentially simple method for storing platelets in the cold....

  4. 76 FR 13019 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Science.gov (United States)

    2011-03-09

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  5. 76 FR 37825 - Agency Information Collection Activities; Generic Clearance for the Collection of Qualitative...

    Science.gov (United States)

    2011-06-28

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Activities; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  6. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    Energy Technology Data Exchange (ETDEWEB)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-10-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure (12 cmH2O continuous positive airway pressure (CPAP)) or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH2O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH2O; clearance and FRC were determined at CPAP of 12 cmH2O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method.

  7. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    International Nuclear Information System (INIS)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-01-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure [12 cmH 2 O continuous positive airway pressure (CPAP)] or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH 2 O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH 2 O; clearance and FRC were determined at CPAP of 12 cmH 2 O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method

  8. Studi Karakteristik Aliran Tiga Dimensi Dan Perpindahan Panas Pada Cascade Airfoil Dengan Pengaruh Clearance

    Directory of Open Access Journals (Sweden)

    Yusuf Wibisono

    2013-03-01

    Full Text Available Dalam dunia teknik khususunya mekanika fluida, aliran tiga dimensi merupakan hal yang sangat penting guna untuk mengetahui fenomena aliran dan perpindahan panas yang terjadi pada bluffbody cascade airfoil. Error atau loses yang terjadi pada cascade airfoil disebabkan oleh adanya aliran sekunder. Error atau loses tersebut menurut penilitian yang terlah dilakukan dapat dikurang dengan aspek clearance. Tujuan dari penilitian ini adalah untuk menganalisa karaktersistik aliran tiga dimensi serta perpindahan panas akibat adanya perubahan jarak antara leading edge antara cascade dan sudut serang serta bentuk geometri. hasil dari simulasi divisualisasikan dalam bentuk velocity dan pressure coefficient. Pada cascade airfoil dengan sudut serang 20° terjadi fenomena pada dinding clearance yaitu tip clearance flow di mana ketika aliran udara melewati dinding akan mengalami up stream yang mengakibatkan arah aliran menuju ke atas, sedangkan pada dinding airfoil ditemukan aliran sekunder berupa curl flow yang akhirnya membentuk spiral point pada trailing edge. Perubahan sudut serang menjadi -20° membuat perbedaan tekanan antara lower side dan upper side semakin lemah, begitu juga tip clearance flow yang terjadi pada wall clearance mengalami perubahan arah menjadi down stream yang mengakibatkan arah aliran menjuu kebawah. Perubahan sudut juga berpengaruh terhadap pressure coeficient pada boundary layer airfoil dan mengakibatkan blockage effect serta terjadinya vortex yang berbeda.

  9. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method

    Science.gov (United States)

    Jiang, Zhinong; Wang, Zijia; Zhang, Jinjie

    2017-01-01

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable. PMID:29244722

  10. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method.

    Science.gov (United States)

    Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie

    2017-12-15

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.

  11. IFNL4 affects clearance of hepatitis C virus

    Science.gov (United States)

    Scientists have discovered a new human interferon gene, Interferon Lambda 4 (IFNL4), that affects clearance of the hepatitis C virus. They also identified an inherited genetic variant within IFNL4 that predicts how people respond to treatment for hepatit

  12. Numerical Analysis of the Influence of Clearance on Stress State and Contact Pressure in Plain Bearings

    Directory of Open Access Journals (Sweden)

    Vasile Cojocaru

    2017-12-01

    Full Text Available In the analysis of plain bearings by finite element method it is important to model as closely to real state the aspects that influence the stress and contact pressure: the loading mode, the properties of the materials, the lubrication system, the clearance between the shaft and the bearing body, the evolution in time of clearance correlated with the wear, etc. In order to study the effect of the clearance on the stress state, a plain bearing with nominal diameter d=40 mm was modeled. The contact pressure and the equivalent stress were computed for six discrete values of clearance, range from c=0 to c=0.3 mm. It has been shown that the increase of clearance generates an increase of the equivalent stress and contact pressure. The growth rate is higher for contact pressure, due to the decrease of the contact surface between the shaft and the bearing body

  13. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    SVSG Nirmala

    2016-01-01

    Full Text Available Background: Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. Objectives: To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Materials and Methods: Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate, filled (wafer and fruit and nuts chocolate, and candy (hard milk and mango-flavored candy groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Results: Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P < 0.05. Conclusion: Dark chocolate had a high fall in pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  14. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial.

    Science.gov (United States)

    Nirmala, Svsg; Quadar, Mohammed Akhil; Veluru, Sindhuri

    2016-01-01

    Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate), filled (wafer and fruit and nuts chocolate), and candy (hard milk and mango-flavored candy) groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  15. Tear clearance and ocular symptoms in patients treated with preservative-free prostaglandins.

    Science.gov (United States)

    Giménez-Gómez, R; García-Catalán, M R; Gallardo-Galera, J M

    2013-03-01

    To assess the effects on dry eye symptoms and tear dynamics of switching from a prostaglandin with a preservative to a preservative-free prostaglandin. Fourteen patients (N=28 eyes) with open-angle glaucoma and dry eye symptons, treated with preserved latanoprost, travoprost or bimatoprost were included in this uncontrolled prospective study. Ocular symptoms were analysed using a validated ocular surface disease questionnaire and ocular signs were assessed with tear clearance, Schirmer and tear function index test (TFI=Schirmer/clearance). Patients were assigned to preservative-free tafluprost treatment, and measurements were repeated 4 weeks after change of medication. Wilcoxon test and Spearman correlation coefficient were used in the statistical analysis. No statistically significant difference in intraocular pressure (IOP) was observed after switching to tafluprost. Mean IOP at baseline was 20.4 mmHg (SD2.2) and after 4 weeks 19.9 mmHg (SD2.6), (P>.05). The mean questionnaire score significantly decreased from 9.7 (SD3.7) at baseline to 5.4 (SD2.7) after one month (P.05). At baseline, tear clearance=0.13 (SD0.07), Schirmer=10.7 mm (SD6) and TFI=80 (48-156). After 4 weeks, tear clearance=0.1(SD0.07), Schirmer=9.5 mm (3.9) and TFI=104 (48-216). A significant association between questionnaire score and tear clearance after 4 weeks was observed (Spearman coefficient=0.62; P=.014). Switching from preservative prostaglandin with a preservative to preservative-free tafluprost treatment improves dry eye symptoms and suggests an improvement in TFI. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  16. Using cholecystokinin to facilitate endoscopic clearance of large common bile duct stones

    Science.gov (United States)

    Tao, Tao; Zhang, Qi-Jie; Zhang, Ming; Zhu, Xiao; Sun, Shu-Xia; Li, Yan-Qing

    2014-01-01

    AIM: To evaluate the effect of cholecystokinin (CCK) during extracorporeal shockwave lithotripsy (ESWL) in the clearance of common bile duct (CBD) stones in endoscopic retrograde cholangiopancreatography (ERCP). METHODS: Between January 2007 and September 2012, patients with large CBD stones who were treated with ESWL and ERCP were identified retrospectively. Patients were randomized in equal numbers to cholecystokinin (CCK) and no CCK groups. For each CCK case, a dose (3 ng/kg per min for 10 min) of sulfated octapeptide of CCK-8 was administered intravenously near the beginning of ESWL. ERCP was performed 4 h after a session of ESWL. The clearance rate of the CBD was assessed between the two groups. RESULTS: A total of 148 consecutive cases (CCK group: 74, no CCK group: 74) were tallied. Overall there were 234 ESWLs and 228 ERCPs in the 148 cases. The use of CCK showed a significantly higher rate of successful stone removal in the first ESWL/ERCP procedure (71.6% vs 55.4%, P = 0.035), but resulted in similar outcomes in the second (42.8% vs 39.4%) and third (41.7% vs 40.0%) sessions, as well as total stone clearance (90.5% vs 83.8%). The use of mechanical lithotripsy was reduced in the CCK group (6.8% vs 17.6%, P = 0.023), and extremely large stone (≥ 30 mm) removal was higher in the CCK group (72.7% vs 41.7%, P = 0.038). CONCLUSION: CCK during ESWL can aid with the clearance of CBD stones in the first ESWL/ERCP session. Mechanical lithotripsy usage was reduced and the extremely large stone (≥ 30 mm) clearance rate can be raised. PMID:25110439

  17. Hepatectomy Based on Future Liver Remnant Plasma Clearance Rate of Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Yuichiro Uchida

    2016-01-01

    Full Text Available Background. Hepatectomy, an important treatment modality for liver malignancies, has high perioperative morbidity and mortality rates. Safe, comprehensive criteria for selecting patients for hepatectomy are needed. Since June 2011, we have used a cut-off value of ≧ 0.05 for future liver remnant plasma clearance rate of indocyanine green as a criterion for hepatectomy. The aim of this study was to verify the validity of this criterion. Methods. From June 2011 to December 2015, 212 hepatectomies were performed in Tenri Yorozu Hospital. Of these 212 patients, 107 who underwent preoperative computed tomography imaging volumetry, indocyanine green clearance test, and hepatectomy (excluding partial resection or enucleation were retrospectively analyzed. Results. There was no postoperative mortality. Posthepatectomy liver failure occurred in 59 patients (55.1% (International Study Group of Liver Surgery Grade A: 43 cases (40.2%, Grade B: 16 cases (15.0%, and Grade C: no cases. Operative morbidity greater than Clavien-Dindo Grade 3 occurred in 23 patients (21.5%. A low future liver remnant plasma clearance rate of indocyanine green was a good predictor for Grade B cases (area under curve = 0.804; 95% confidence interval, 0.712–0.895. Conclusion. Liver remnant plasma clearance rate of indocyanine green is a valid criterion for hepatectomy.

  18. Evaluation of plasma clearance by synthesis of continuous infusion: principles and use

    International Nuclear Information System (INIS)

    Chonacky, N.J.; Thomas, F.D.

    1986-01-01

    There is a technique of engineering analysis which can be described as impulse synthesis which uses the observational data of a system's response to a single sharp blow in order to predict its response to a steady force. This same technique has been applied to the calculation of in situ drug levels and for calculating plasma clearance values. The purpose of this paper is to elucidate the principles of this calculation technique and to critically assess its application to plasma clearance studies. We begin by tracing the history of the measurement of renal clearance of plasma. We then proceed to exposit the relevant principles of the synthesis technique. Finally, we report the results of our application of this technique to the analysis of simulated data in a manner intended to be of use to clinicians who might wish to consider employing the technique

  19. Effect of α-naphthylisothiocyanate on blood clearance of 99mTc-phytate in dogs

    International Nuclear Information System (INIS)

    Shibata, Hiroshi; Kohno, Masahiro; Katoh, Hirotake

    1989-01-01

    The effect of α-naphthylisothiocyanate (ANIT) on blood clearance of 99m Tc-phytate ( 99m Tc-P) in dogs was examined, and blood clearance test of 99m Tc-P was compared with the cases of serum transaminase test or serum bilirubin test. Serum transaminase and bilirubin levels in dogs increased after ANIT administration, however, the degree of increase in these parameters was much lower than the cases in rats. The disappearance rate of 99m Tc-P from blood in dogs decreased with the increase in dose of ANIT and with the passage of time after the ANIT administration. Changes of the blood clearance of 99m Tc-P after ANIT treatment in dogs may be influenced by the disorder in the hepatocytes rather than in the bile ductule cells. The blood clearance test of 99m Tc-P in dogs showed a sensitive reaction for the acute hepatic dysfunction induced by ANIT equally to the serum transaminase test or the serum bilirubin test. (author)

  20. 76 FR 45645 - 10-Day Notice of Proposed Information Collection: Technology Security/Clearance Plans, Screening...

    Science.gov (United States)

    2011-07-29

    ...: Technology Security/Clearance Plans, Screening Records, and Non-Disclosure Agreements ACTION: Notice of... Information Collection: Technology Security/ Clearance Plans, Screening Records, and Non-Disclosure Agreements...: None. Respondents: Business and Nonprofit Organizations, Foreign Governments. Estimated Number of...