WorldWideScience

Sample records for accuracy profile procedure

  1. Potential of accuracy profile for method validation in inductively coupled plasma spectrochemistry

    International Nuclear Information System (INIS)

    Mermet, J.M.; Granier, G.

    2012-01-01

    Method validation is usually performed over a range of concentrations for which analytical criteria must be verified. One important criterion in quantitative analysis is accuracy, i.e. the contribution of both trueness and precision. The study of accuracy over this range is called an accuracy profile and provides experimental tolerance intervals. Comparison with acceptability limits fixed by the end user defines a validity domain. This work describes the computation involved in the building of the tolerance intervals, particularly for the intermediate precision with within-laboratory experiments and for the reproducibility with interlaboratory studies. Computation is based on ISO 5725‐4 and on previously published work. Moreover, the bias uncertainty is also computed to verify the bias contribution to accuracy. The various types of accuracy profile behavior are exemplified with results obtained by using ICP-MS and ICP-AES. This procedure allows the analyst to define unambiguously a validity domain for a given accuracy. However, because the experiments are time-consuming, the accuracy profile method is mainly dedicated to method validation. - Highlights: ► An analytical method is defined by its accuracy, i.e. both trueness and precision. ► The accuracy as a function of an analyte concentration is an accuracy profile. ► Profile basic concepts are explained for trueness and intermediate precision. ► Profile-based tolerance intervals have to be compared with acceptability limits. ► Typical accuracy profiles are given for both ICP-AES and ICP-MS techniques.

  2. Believing is seeing? Investigating the perceived accuracy of criminal psychological profiles.

    Science.gov (United States)

    Kocsis, Richard N; Hayes, Andrew F

    2004-04-01

    This study investigated whether perceptions of criminal psychological profiles are influenced by the identity of the profile's author. Police officers were given a profile they were told was written by either a professional profiler or by an unspecified author. When judged in relation to the actual perpetrator of the crime, police officers tended to perceive greater accuracy in a profile when it was labeled as authored by a professional profiler independent of the actual content of the profile. But officers' judgments of the usefulness of the profile were not affected by knowledge of who wrote the profile. Explanations for this result focus on the ambiguous nature of criminal profiles and how this ambiguity enhances the likelihood that beliefs about the validity of profiling can color perceptions of the content of the profile.

  3. Commissioning Procedures for Mechanical Precision and Accuracy in a Dedicated LINAC

    International Nuclear Information System (INIS)

    Ballesteros-Zebadua, P.; Larrga-Gutierrez, J. M.; Garcia-Garduno, O. A.; Juarez, J.; Prieto, I.; Moreno-Jimenez, S.; Celis, M. A.

    2008-01-01

    Mechanical precision measurements are fundamental procedures for the commissioning of a dedicated LINAC. At our Radioneurosurgery Unit, these procedures can be suitable as quality assurance routines that allow the verification of the equipment geometrical accuracy and precision. In this work mechanical tests were performed for gantry and table rotation, obtaining mean associated uncertainties of 0.3 mm and 0.71 mm, respectively. Using an anthropomorphic phantom and a series of localized surface markers, isocenter accuracy showed to be smaller than 0.86 mm for radiosurgery procedures and 0.95 mm for fractionated treatments with mask. All uncertainties were below tolerances. The highest contribution to mechanical variations is due to table rotation, so it is important to correct variations using a localization frame with printed overlays. Mechanical precision knowledge would allow to consider the statistical errors in the treatment planning volume margins

  4. Investigation on a procedure for optimal axial depth of cut accuracy in micromilling

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    On the basis of a previously developed procedure for control of axial depth of cut in high accuracy micromilling operations, this paper presents an investigation on the estimation of the uncertainty of the set axial depth of cut.......On the basis of a previously developed procedure for control of axial depth of cut in high accuracy micromilling operations, this paper presents an investigation on the estimation of the uncertainty of the set axial depth of cut....

  5. Nose profile morphology and accuracy study of nose profile estimation method in Scottish subadult and Indonesian adult populations.

    Science.gov (United States)

    Sarilita, Erli; Rynn, Christopher; Mossey, Peter A; Black, Sue; Oscandar, Fahmi

    2018-05-01

    This study investigated nose profile morphology and its relationship to the skull in Scottish subadult and Indonesian adult populations, with the aim of improving the accuracy of forensic craniofacial reconstruction. Samples of 86 lateral head cephalograms from Dundee Dental School (mean age, 11.8 years) and 335 lateral head cephalograms from the Universitas Padjadjaran Dental Hospital, Bandung, Indonesia (mean age 24.2 years), were measured. The method of nose profile estimation based on skull morphology previously proposed by Rynn and colleagues in 2010 (FSMP 6:20-34) was tested in this study. Following this method, three nasal aperture-related craniometrics and six nose profile dimensions were measured from the cephalograms. To assess the accuracy of the method, six nose profile dimensions were estimated from the three craniometric parameters using the published method and then compared to the actual nose profile dimensions.In the Scottish subadult population, no sexual dimorphism was evident in the measured dimensions. In contrast, sexual dimorphism of the Indonesian adult population was evident in all craniometric and nose profile dimensions; notably, males exhibited statistically significant larger values than females. The published method by Rynn and colleagues (FSMP 6:20-34, 2010) performed better in the Scottish subadult population (mean difference of maximum, 2.35 mm) compared to the Indonesian adult population (mean difference of maximum, 5.42 mm in males and 4.89 mm in females).In addition, regression formulae were derived to estimate nose profile dimensions based on the craniometric measurements for the Indonesian adult population. The published method is not sufficiently accurate for use on the Indonesian population, so the derived method should be used. The accuracy of the published method by Rynn and colleagues (FSMP 6:20-34, 2010) was sufficiently reliable to be applied in Scottish subadult population.

  6. A new procedure to measure children's reading speed and accuracy in Italian.

    Science.gov (United States)

    Morlini, Isabella; Stella, Giacomo; Scorza, Maristella

    2014-02-01

    Impaired readers in primary school should be early recognized, in order to asses a targeted intervention within the school and to start a teaching that respects the difficulties in learning to read, to write and to perform calculations. Screening procedures, inside the primary schools aimed at detecting children with difficulties in reading, are of fundamental importance for guaranteeing an early identification of dyslexic children and reducing both the primary negative effects--on learning--and the secondary negative effects--on the development of the personality--of this disturbance. In this study, we propose a new screening procedure measuring reading speed and accuracy. This procedure is very fast (it is exactly 1 min long), simple, cheap and can be provided by teachers without technical knowledge. On the contrary, most of the currently used diagnostic tests are about 10 min long and must be provided by experts. These two major flaws prevent the widespread use of these tests. On the basis of the results obtained in a survey on about 1500 students attending primary school in Italy, we investigate the relationships between variables used in the screening procedure and variables measuring speed and accuracy in the currently used diagnostic tests in Italy. Then, we analyse the validity of the screening procedure from a statistical point of view, and with an explorative factor analysis, we show that reading speed and accuracy seem to be two separate symptoms of the dyslexia phenomenon. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Whole-procedure clinical accuracy of Gamma Knife treatments of large lesions

    International Nuclear Information System (INIS)

    Ma Lijun; Chuang, Cynthia; Descovich, Martina; Petti, Paula; Smith, Vernon; Verhey, Lynn

    2008-01-01

    The mechanical accuracy of Gamma Knife radiosurgery based on single-isocenter measurement has been established to within 0.3 mm. However, the full delivery accuracy for Gamma Knife treatments of large lesions has only been estimated via the quadrature-sum analysis. In this study, the authors directly measured the whole-procedure accuracy for Gamma Knife treatments of large lesions to examine the validity of such estimation. The measurements were conducted on a head-phantom simulating the whole treatment procedure that included frame placement, computed tomography imaging, treatment planning, and treatment delivery. The results of the measurements were compared with the dose calculations from the treatment planning system. Average agreements of 0.1-1.6 mm for the isodose lines ranging from 25% to 90% of the maximum dose were found despite potentially large contributing uncertainties such as 3-mm imaging resolution, 2-mm dose grid size, 1-mm frame registration, multi-isocenter deliveries, etc. The results of our measurements were found to be significantly smaller (>50%) than the calculated value based on the quadrature-sum analysis. In conclusion, Gamma Knife treatments of large lesions can be delivered much more accurately than predicted from the quadrature-sum analysis of major sources of uncertainties from each step of the delivery chain.

  8. Differentiation of ileostomy from colostomy procedures: assessing the accuracy of current procedural terminology codes and the utility of natural language processing.

    Science.gov (United States)

    Vo, Elaine; Davila, Jessica A; Hou, Jason; Hodge, Krystle; Li, Linda T; Suliburk, James W; Kao, Lillian S; Berger, David H; Liang, Mike K

    2013-08-01

    Large databases provide a wealth of information for researchers, but identifying patient cohorts often relies on the use of current procedural terminology (CPT) codes. In particular, studies of stoma surgery have been limited by the accuracy of CPT codes in identifying and differentiating ileostomy procedures from colostomy procedures. It is important to make this distinction because the prevalence of complications associated with stoma formation and reversal differ dramatically between types of stoma. Natural language processing (NLP) is a process that allows text-based searching. The Automated Retrieval Console is an NLP-based software that allows investigators to design and perform NLP-assisted document classification. In this study, we evaluated the role of CPT codes and NLP in differentiating ileostomy from colostomy procedures. Using CPT codes, we conducted a retrospective study that identified all patients undergoing a stoma-related procedure at a single institution between January 2005 and December 2011. All operative reports during this time were reviewed manually to abstract the following variables: formation or reversal and ileostomy or colostomy. Sensitivity and specificity for validation of the CPT codes against the mastery surgery schedule were calculated. Operative reports were evaluated by use of NLP to differentiate ileostomy- from colostomy-related procedures. Sensitivity and specificity for identifying patients with ileostomy or colostomy procedures were calculated for CPT codes and NLP for the entire cohort. CPT codes performed well in identifying stoma procedures (sensitivity 87.4%, specificity 97.5%). A total of 664 stoma procedures were identified by CPT codes between 2005 and 2011. The CPT codes were adequate in identifying stoma formation (sensitivity 97.7%, specificity 72.4%) and stoma reversal (sensitivity 74.1%, specificity 98.7%), but they were inadequate in identifying ileostomy (sensitivity 35.0%, specificity 88.1%) and colostomy (75

  9. Semi-empirical procedures for correcting detector size effect on clinical MV x-ray beam profiles

    International Nuclear Information System (INIS)

    Sahoo, Narayan; Kazi, Abdul M.; Hoffman, Mark

    2008-01-01

    The measured radiation beam profiles need to be corrected for the detector size effect to derive the real profiles. This paper describes two new semi-empirical procedures to determine the real profiles of high-energy x-ray beams by removing the detector size effect from the measured profiles. Measured profiles are corrected by shifting the position of each measurement point by a specific amount determined from available theoretical and experimental knowledge in the literature. The authors developed two procedures to determine the amount of shift. In the first procedure, which employs the published analytical deconvolution procedure of other investigators, the shift is determined from the comparison of the analytical fit of the measured profile and the corresponding analytical real profile derived from the deconvolution of the fitted measured profile and the Gaussian detector response function. In the second procedure, the amount of shift at any measurement point is considered to be proportional to the value of an analytical function related to the second derivative of the real profile at that point. The constant of proportionality and a parameter in the function are obtained from the values of the shifts at the 90%, 80%, 20%, and 10% dose levels, which are experimentally known from the published results of other investigators to be approximately equal to half of the radius of the detector. These procedures were tested by correcting the profiles of 6 and 18 MV x-ray beams measured by three different ionization chambers and a stereotactic field diode detector with 2.75, 2, 1, and 0.3 mm radii of their respective active cylindrical volumes. The corrected profiles measured by different detectors are found to be in close agreement. The detector size corrected penumbra widths also agree with the expected values based on the results of an earlier investigation. Thus, the authors concluded that the proposed procedures are accurate and can be used to derive the real

  10. Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time

    International Nuclear Information System (INIS)

    Hoffmann, Ruediger; Thomas, Christoph; Rempp, Hansjoerg; Schmidt, Diethard; Claussen, Claus D.; Clasen, Stephan; Pereira, Philippe L.

    2012-01-01

    To assess the accuracy, the duration and factors that influence the duration of MRI-guided liver or soft-tissue biopsies. Nineteen liver biopsies and 19 soft-tissue biopsies performed using 1.5T-MRI guidance were retrospectively analysed. Diagnostic performance and complications were assessed. Intervention time was subdivided into preparation period, puncture period and control period. Correlation between procedure time and target size, skin-to-target-distance, used sequences and interventionalists' experience were analysed. Overall sensitivity, specificity and accuracy were 0.86, 1.0 and 0.92, respectively. Two minor complications occurred. Overall median procedure time was 103.5 min. Liver biopsies lasted longer than soft-tissue biopsies (mean [soft-tissue] : 73.0 min, mean [liver] : 134.1 min, P [liver] = 0.048, P [soft-tissue] = 0.005) was significantly prolonged for longer skin-to-target-distances. Lower numbers of image acquisitions (P [liver] = 0.0007, P [soft-tissue] = 0.0012) and interventionalists' experience reduces the procedure duration significantly (P < 0.05), besides all false-negative results appeared during the first five biopsies of each individual radiologist. The interventionalists' experience, skin-to-target-distances and number of image acquisition influence the procedure time significantly. (orig.)

  11. Accuracy of clinical coding for procedures in oral and maxillofacial surgery.

    Science.gov (United States)

    Khurram, S A; Warner, C; Henry, A M; Kumar, A; Mohammed-Ali, R I

    2016-10-01

    Clinical coding has important financial implications, and discrepancies in the assigned codes can directly affect the funding of a department and hospital. Over the last few years, numerous oversights have been noticed in the coding of oral and maxillofacial (OMF) procedures. To establish the accuracy and completeness of coding, we retrospectively analysed the records of patients during two time periods: March to May 2009 (324 patients), and January to March 2014 (200 patients). Two investigators independently collected and analysed the data to ensure accuracy and remove bias. A large proportion of operations were not assigned all the relevant codes, and only 32% - 33% were correct in both cycles. To our knowledge, this is the first reported audit of clinical coding in OMFS, and it highlights serious shortcomings that have substantial financial implications. Better input by the surgical team and improved communication between the surgical and coding departments will improve accuracy. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Accuracy of non-fasting lipid profile for the assessment of lipoprotein coronary risk

    International Nuclear Information System (INIS)

    Fatima, S.; Ijaz, A.; Sharif, T.; Khan, D.A.; Siddique, A.

    2016-01-01

    To determine the diagnostic accuracy of non-fasting lipid profile in the diagnosis of hyperlipidemia, taking fasting lipid profile as gold standard, in adult population. Study Design: Cross sectional validation study. Place and Duration of Study: Department of chemical pathology and endocrinology, armed forces institute of pathology, rawalpindi, from july to december 2014. Methodology: One hundred seventy five adult patients coming for fasting lipid prodile were included; their non-fasting samples were taken on the next day. patients on anti-cholesterol treatment and indoor patients were excluded. Total cholesterol (TC), high density lipoprotein-cholestrol (HDL-C), and triglycerides were measured by direct enzymatic calorimetric method by modular p-800 rate. Low density lipoprotein-cholesterol (LDL-C) was calculated by friendewald's formula but when triglyceride was greater than 4.5mol/l, then LDL-C was measured directly by homogenous enzymatic colorimetric method. non-fasting lipid profile had 93% specificity, 51% sensitivity, 94% positive predictive value and 49% negative predictive value and 65% accuracy with 7.28 positive likehood ratio and 0.52 negative likelihood ratio. Non fasting TC and non-HDLC were significantly higher than fasting TC and non-HDL-c by mean difference of 0.2 mmol/l each with p=0.001 and p=0.004, respectively. fasting and on fasting HDLC-are comparable to each other with mean difference of 0.01 mmol/l (p=0.745) Receiver operating curve (ROC) of non fasting non HDLC-C showed 0.84 (95% Cl (0.738-0.870), p=0.000) area under the curve (AUC) indicating that it was a significant test for ruling out hyperlipdemia. Bland-altmann plot showed a significant difference between non fasting, non HDLC-C and fasting LDL-C and non fasting, non-HDL-C -0.087540 with base -0.00109; therefore, these cannot be alternative to each other. Conclusion: Diagnostic accuracy of non-fasting lipid profile was found significantly higher than fasting lipid profile (p=0

  13. Procedural Documentation and Accuracy Assessment of Bathymetric Maps and Area/Capacity Tables for Small Reservoirs

    Science.gov (United States)

    Wilson, Gary L.; Richards, Joseph M.

    2006-01-01

    Because of the increasing use and importance of lakes for water supply to communities, a repeatable and reliable procedure to determine lake bathymetry and capacity is needed. A method to determine the accuracy of the procedure will help ensure proper collection and use of the data and resulting products. It is important to clearly define the intended products and desired accuracy before conducting the bathymetric survey to ensure proper data collection. A survey-grade echo sounder and differential global positioning system receivers were used to collect water-depth and position data in December 2003 at Sugar Creek Lake near Moberly, Missouri. Data were collected along planned transects, with an additional set of quality-assurance data collected for use in accuracy computations. All collected data were imported into a geographic information system database. A bathymetric surface model, contour map, and area/capacity tables were created from the geographic information system database. An accuracy assessment was completed on the collected data, bathymetric surface model, area/capacity table, and contour map products. Using established vertical accuracy standards, the accuracy of the collected data, bathymetric surface model, and contour map product was 0.67 foot, 0.91 foot, and 1.51 feet at the 95 percent confidence level. By comparing results from different transect intervals with the quality-assurance transect data, it was determined that a transect interval of 1 percent of the longitudinal length of Sugar Creek Lake produced nearly as good results as 0.5 percent transect interval for the bathymetric surface model, area/capacity table, and contour map products.

  14. Accuracy Profiles for Analyzing Residual Solvents in Textiles by GC-MS.

    Science.gov (United States)

    Bao, Qibei; Fu, Kejie; Ren, Qingqing; Zhong, Yingying; Qian, Dan

    2017-10-01

    Excess residual solvents (RSs) in clothes or other textiles could be toxic and pose risks to both humans and the environment. N,N-Dimethylformamide (DMF), N,N-dimethylacetamide (DMAc) and 1-methyl-2-pyrrolidinone (NMP) are important chemicals frequently used as solvents in the textile industry. Several organizations have proposed limiting DMF, DMAc and NMP in textiles, but an appropriate detection method has not been proposed. A sensitive GC-MS method for the quantification of DMF, DMAc and NMP in textiles was developed. After extraction with ethyl acetate, these RSs were separated on a DB-5MS capillary column. The oven temperature was increased from 50°C (held for 0.5 min) at 10°C/min to 120°C (held for 1 min). The method was fully validated according to the accuracy profile procedure, which is based on β-expectation tolerance intervals for the total measurement bias. Linearity was observed in the range of 0.5-10 mg/L for the solvents with limit of quantification values of 4.2, 3.5 and 2.5 mg/kg for DMF, DMAc and NMP, respectively. The repeatability and intermediate precision were NMP. The recoveries of DMF, DMAc and NMP were 91.2-106.3%, 89.5-97.7% and 85.6-101.3%, respectively. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Procedure for analyzing the x-ray line profiles of disordered carbons

    International Nuclear Information System (INIS)

    Henry, L.G.; Bragg, R.H.; Bose, S.

    1981-12-01

    A systematic procedure to correct for various distortions in the broad x-ray line profiles of glass-like carbons (GC) is described. The profile is first corrected for distortions due to low specimen absorption, secondly for incoherent (Compton) scattering, and then strong small angle scattering. The resulting profile is then multiplied by the appropriate trigonometric (Lorentz and polarization) factors. Finally, correction is made for the variation of the atomic scattering factor across the broad peaks. Two examples of the GC heat treatment at 1000 0 C and 2700 0 C have been used to illustrate the outcome of the corrections. 8 figures

  16. A methodological approach to assessing alveolar ridge preservation procedures in humans: soft tissue profile.

    Science.gov (United States)

    Vanhoutte, Vanessa; Rompen, Eric; Lecloux, Geoffrey; Rues, Stefan; Schmitter, Marc; Lambert, France

    2014-03-01

    The aesthetic results of implant restoration in the anterior maxilla are particularly related to the soft tissue profile. Although socket preservation techniques appear to reduce bone remodelling after tooth extraction, there is still few investigations assessing the external soft tissue profile after such procedures. The goal of this study was to describe an accurate technique to evaluate soft tissue contour changes after performing socket preservation procedures. The secondary objective was to apply the newly developed measuring method to a specific socket preservation using a "saddled" connective tissue graft combined with the insertion of slowly resorbable biomaterials into the socket. A total of 14 patients needing tooth replacement in the aesthetic region were included to receive a socket preservation procedure using a connective tissue graft. Impressions were taken before the tooth extraction (baseline) and at 2, 4, and 12 weeks after the procedure. The corresponding plaster casts were scanned, and the evolution of the soft tissue profile in relation to the baseline situation was assessed using imaging software. The measuring technique allowed assessing the soft tissue profiles accurately at different levels of the alveolar process. The insertion of a saddled connective tissue appeared to compensate for the horizontal and vertical bone remodelling after a socket preservation procedure in most regions of the alveolar crest. After 12 weeks, the only significant change was located in the more cervical and central region of the alveolar process and reached a median drop of 0.62 mm from baseline. Within the limitations of this study, we found that a saddled connective tissue graft combined with a socket preservation procedure could almost completely counteract the bone remodelling in terms of the external soft tissue profile. The minor changes found in the cervical region might disappear with the emergence profile of the prosthodontic components. The described

  17. Procedure to determine the two channel timing measurement accuracy and precision of a digital oscilloscope

    International Nuclear Information System (INIS)

    Johnson, M.; Matulik, M.

    1994-01-01

    The digital oscilloscope allows one to make numerous timing measurements, but just how good are those measurements? This document describes a procedure which can be used to determine the accuracy and precision to which a digital oscilloscope can make various two channel timing measurements

  18. Accuracy of Buccal Scan Procedures for the Registration of Habitual Intercuspation.

    Science.gov (United States)

    Zimmermann, M; Ender, A; Attin, T; Mehl, A

    2018-04-09

    Accurate reproduction of the jaw relationship is important in many fields of dentistry. Maximum intercuspation can be registered with digital buccal scan procedures implemented in the workflow of many intraoral scanning systems. The aim of this study was to investigate the accuracy of buccal scan procedures with intraoral scanning devices for the registration of habitual intercuspation in vivo. The hypothesis was that there is no statistically significant difference for buccal scan procedures compared to registration methods with poured model casts. Ten individuals (full dentition, no dental rehabilitations) were subjects for five different habitual intercuspation registration methods: (CI) poured model casts, manual hand registration, buccal scan with inEOS X5; (BC) intraoral scan, buccal scan with CEREC Bluecam; (OC4.2) intraoral scan, buccal scan with CEREC Omnicam software version 4.2; (OC4.5β) intraoral scan, buccal scan with CEREC Omnicam version 4.5β; and (TR) intraoral scan, buccal scan with Trios 3. Buccal scan was repeated three times. Analysis of rotation (Rot) and translation (Trans) parameters was performed with difference analysis software (OraCheck). Statistical analysis was performed with one-way analysis of variance and the post hoc Scheffé test ( p0.05) differences in terms of translation between groups CI_Trans (98.74±112.01 μm), BC_Trans (84.12±64.95 μm), OC4.2_Trans (60.70±35.08 μm), OC4.5β_Trans (68.36±36.67 μm), and TR_Trans (66.60±64.39 μm). For rotation, there were no significant differences ( p>0.05) for groups CI_Rot (0.23±0.25°), BC_Rot (0.73±0.52°), OC4.2_Rot (0.45±0.31°), OC4.5β_Rot (0.50±0.36°), and TR_Rot (0.47±0.65°). Intraoral scanning devices allow the reproduction of the static relationship of the maxillary and mandibular teeth with the same accuracy as registration methods with poured model casts.

  19. Accuracy of axial depth of cut in micromilling operations - Simplified procedure and uncertainty model

    DEFF Research Database (Denmark)

    Bissacco, Giuliano

    2005-01-01

    , due to the easy breakage particularly when milling on hard materials [1]. Typical values for the errors on the control of the axial depth of cut are in the order of 50 microns, while the aimed depth of cut can be as low as 5 microns. The author has developed a machining procedure for optimal control...... of this investigation is the determination of the uncertainty of the set depth of cut, using the developed procedure, in a range of practical operating conditions and thereby the estimation of the expected accuracy of the method prior to verification of the machined parts....

  20. Evaluation of vertical profiles to design continuous descent approach procedure

    Science.gov (United States)

    Pradeep, Priyank

    The current research focuses on predictability, variability and operational feasibility aspect of Continuous Descent Approach (CDA), which is among the key concepts of the Next Generation Air Transportation System (NextGen). The idle-thrust CDA is a fuel economical, noise and emission abatement procedure, but requires increased separation to accommodate for variability and uncertainties in vertical and speed profiles of arriving aircraft. Although a considerable amount of researches have been devoted to the estimation of potential benefits of the CDA, only few have attempted to explain the predictability, variability and operational feasibility aspect of CDA. The analytical equations derived using flight dynamics and Base of Aircraft and Data (BADA) Total Energy Model (TEM) in this research gives insight into dependency of vertical profile of CDA on various factors like wind speed and gradient, weight, aircraft type and configuration, thrust settings, atmospheric factors (deviation from ISA (DISA), pressure and density of the air) and descent speed profile. Application of the derived equations to idle-thrust CDA gives an insight into sensitivity of its vertical profile to multiple factors. This suggests fixed geometric flight path angle (FPA) CDA has higher degree of predictability and lesser variability at the cost of non-idle and low thrust engine settings. However, with optimized design this impact can be overall minimized. The CDA simulations were performed using Future ATM Concept Evaluation Tool (FACET) based on radar-track and aircraft type data (BADA) of the real air-traffic to some of the busiest airports in the USA (ATL, SFO and New York Metroplex (JFK, EWR and LGA)). The statistical analysis of the vertical profiles of CDA shows 1) mean geometric FPAs derived from various simulated vertical profiles are consistently shallower than 3° glideslope angle and 2) high level of variability in vertical profiles of idle-thrust CDA even in absence of

  1. Development of an automated desktop procedure for defining macro-reaches for river longitudinal profiles

    CSIR Research Space (South Africa)

    Dollar, LH

    2006-07-01

    Full Text Available This paper presents an automated desktop procedure for delineating river longitudinal profiles into macro-reaches for use in Ecological Reserve assessments and to aid freshwater ecosystem conservation planning. The procedure was developed for use...

  2. Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

    Science.gov (United States)

    Marheineke, Nadine; Scherer, Uta; Rücker, Martin; von See, Constantin; Rahlf, Björn; Gellrich, Nils-Claudius; Stoetzer, Marcus

    2018-06-01

    Dental implant failure and insufficient osseointegration are proven results of mechanical and thermal damage during the surgery process. We herein performed a comparative study of a less invasive single-step drilling preparation protocol and a conventional multiple drilling sequence. Accuracy of drilling holes was precisely analyzed and the influence of different levels of expertise of the handlers and additional use of drill template guidance was evaluated. Six experimental groups, deployed in an osseous study model, were representing template-guided and freehanded drilling actions in a stepwise drilling procedure in comparison to a single-drill protocol. Each experimental condition was studied by the drilling actions of respectively three persons without surgical knowledge as well as three highly experienced oral surgeons. Drilling actions were performed and diameters were recorded with a precision measuring instrument. Less experienced operators were able to significantly increase the drilling accuracy using a guiding template, especially when multi-step preparations are performed. Improved accuracy without template guidance was observed when experienced operators were executing single-step versus multi-step technique. Single-step drilling protocols have shown to produce more accurate results than multi-step procedures. The outcome of any protocol can be further improved by use of guiding templates. Operator experience can be a contributing factor. Single-step preparations are less invasive and are promoting osseointegration. Even highly experienced surgeons are achieving higher levels of accuracy by combining this technique with template guidance. Hereby template guidance enables a reduction of hands-on time and side effects during surgery and lead to a more predictable clinical diameter.

  3. Goldmann applanation tonometry over daily disposable contact lens: accuracy and safety of procedure.

    Science.gov (United States)

    Zeri, Fabrizio; Lupelli, Luigi; Formichella, Paolo; Masci, Carlo; Fletcher, Robert

    2007-09-01

    To study accuracy and safety, related to sensation (discomfort) and trauma, when using Goldmann applanation tonometry (GAT) on eyes wearing daily disposable soft contact lenses. The intra-ocular pressure (IOP) of 136 normal eyes of 68 subjects was measured by Goldmann tonometer. Measurements were made in one eye with a contact lens (hilafilcon A) without anaesthetic drops and then without the contact lens using one drop of 0.4% oxybuprocaine hydrochloride. Each contact lens used was identical as to back optic zone, back vertex power. Standard Goldmann procedure only was used for the fellow eye of each subject. Subjective sensation (discomfort) responses to both procedures were studied in a subgroup (66 eyes) using a scale of discomfort, from 1 (no sensation) to 5 (highest sensation). Epithelial staining after tonometry was evaluated for this subgroup. No significant differences were found for the IOP with and without contact lens (tcontact lens insertion, tonometry on contact lens and application of topical anaesthetic). Corneal epithelial staining following the standard tonometry procedure was significantly higher than following the procedure with a contact lens (pcontact lens is accurate, compared to the standard procedure and within the IOP's normal range studied here. Also using a contact lens results in less trauma whilst discomfort is similar.

  4. Improving the surface metrology accuracy of optical profilers by using multiple measurements

    Science.gov (United States)

    Xu, Xudong; Huang, Qiushi; Shen, Zhengxiang; Wang, Zhanshan

    2016-10-01

    The performance of high-resolution optical systems is affected by small angle scattering at the mid-spatial-frequency irregularities of the optical surface. Characterizing these irregularities is, therefore, important. However, surface measurements obtained with optical profilers are influenced by additive white noise, as indicated by the heavy-tail effect observable on their power spectral density (PSD). A multiple-measurement method is used to reduce the effects of white noise by averaging individual measurements. The intensity of white noise is determined using a model based on the theoretical PSD of fractal surface measurements with additive white noise. The intensity of white noise decreases as the number of times of multiple measurements increases. Using multiple measurements also increases the highest observed spatial frequency; this increase is derived and calculated. Additionally, the accuracy obtained using multiple measurements is carefully studied, with the analysis of both the residual reference error after calibration, and the random errors appearing in the range of measured spatial frequencies. The resulting insights on the effects of white noise in optical profiler measurements and the methods to mitigate them may prove invaluable to improve the quality of surface metrology with optical profilers.

  5. Finite element design procedure for correcting the coining die profiles

    Science.gov (United States)

    Alexandrino, Paulo; Leitão, Paulo J.; Alves, Luis M.; Martins, Paulo A. F.

    2018-05-01

    This paper presents a new finite element based design procedure for correcting the coining die profiles in order to optimize the distribution of pressure and the alignment of the resultant vertical force at the end of the die stroke. The procedure avoids time consuming and costly try-outs, does not interfere with the creative process of the sculptors and extends the service life of the coining dies by significantly decreasing the applied pressure and bending moments. The numerical simulations were carried out in a computer program based on the finite element flow formulation that is currently being developed by the authors in collaboration with the Portuguese Mint. A new experimental procedure based on the stack compression test is also proposed for determining the stress-strain curve of the materials directly from the coin blanks.

  6. A New Image Processing Procedure Integrating PCI-RPC and ArcGIS-Spline Tools to Improve the Orthorectification Accuracy of High-Resolution Satellite Imagery

    Directory of Open Access Journals (Sweden)

    Hongying Zhang

    2016-10-01

    Full Text Available Given the low accuracy of the traditional remote sensing image processing software when orthorectifying satellite images that cover mountainous areas, and in order to make a full use of mutually compatible and complementary characteristics of the remote sensing image processing software PCI-RPC (Rational Polynomial Coefficients and ArcGIS-Spline, this study puts forward a new operational and effective image processing procedure to improve the accuracy of image orthorectification. The new procedure first processes raw image data into an orthorectified image using PCI with RPC model (PCI-RPC, and then the orthorectified image is further processed using ArcGIS with the Spline tool (ArcGIS-Spline. We used the high-resolution CBERS-02C satellite images (HR1 and HR2 scenes with a pixel size of 2 m acquired from Yangyuan County in Hebei Province of China to test the procedure. In this study, when separately using PCI-RPC and ArcGIS-Spline tools directly to process the HR1/HR2 raw images, the orthorectification accuracies (root mean square errors, RMSEs for HR1/HR2 images were 2.94 m/2.81 m and 4.65 m/4.41 m, respectively. However, when using our newly proposed procedure, the corresponding RMSEs could be reduced to 1.10 m/1.07 m. The experimental results demonstrated that the new image processing procedure which integrates PCI-RPC and ArcGIS-Spline tools could significantly improve image orthorectification accuracy. Therefore, in terms of practice, the new procedure has the potential to use existing software products to easily improve image orthorectification accuracy.

  7. Verification of examination procedures in clinical laboratory for imprecision, trueness and diagnostic accuracy according to ISO 15189:2012: a pragmatic approach.

    Science.gov (United States)

    Antonelli, Giorgia; Padoan, Andrea; Aita, Ada; Sciacovelli, Laura; Plebani, Mario

    2017-08-28

    Background The International Standard ISO 15189 is recognized as a valuable guide in ensuring high quality clinical laboratory services and promoting the harmonization of accreditation programmes in laboratory medicine. Examination procedures must be verified in order to guarantee that their performance characteristics are congruent with the intended scope of the test. The aim of the present study was to propose a practice model for implementing procedures employed for the verification of validated examination procedures already used for at least 2 years in our laboratory, in agreement with the ISO 15189 requirement at the Section 5.5.1.2. Methods In order to identify the operative procedure to be used, approved documents were identified, together with the definition of performance characteristics to be evaluated for the different methods; the examination procedures used in laboratory were analyzed and checked for performance specifications reported by manufacturers. Then, operative flow charts were identified to compare the laboratory performance characteristics with those declared by manufacturers. Results The choice of performance characteristics for verification was based on approved documents used as guidance, and the specific purpose tests undertaken, a consideration being made of: imprecision and trueness for quantitative methods; diagnostic accuracy for qualitative methods; imprecision together with diagnostic accuracy for semi-quantitative methods. Conclusions The described approach, balancing technological possibilities, risks and costs and assuring the compliance of the fundamental component of result accuracy, appears promising as an easily applicable and flexible procedure helping laboratories to comply with the ISO 15189 requirements.

  8. Effects of Inner Surface Roughness and Asymmetric Pipe Flow on Accuracy of Profile Factor for Ultrasonic Flow Meter

    International Nuclear Information System (INIS)

    Michitsugu Mori; Kenichi Tezuka; Yasushi Takeda

    2006-01-01

    Flow profile factors (PFs), which adjust measurements to real flow rates, also strongly depend on flow profiles. To determine profile factors for actual power plants, manufactures of flowmeters usually conduct factory calibration tests under ambient flow conditions. Indeed, flow measurements with high accuracy for reactor feedwater require them to conduct calibration tests under real conditions, such as liquid conditions and piping layouts. On the contrary, as nuclear power plants are highly aging, readings of flowmeters for reactor feedwater systems drift due to the changes of flow profiles. The causes of those deviations are affected by the change of wall roughness of inner surface of pipings. We have conducted experiments to quantify the effects of flow patterns on the PFs due to pipe roughness and asymmetric flow, and the results of our experiments have shown the effects of elbows and pipe inner roughness, which strongly affect to the creation of the flow patterns. Those changes of flow patterns lead to large errors in measurements with transit time (time-of-flight: TOF) ultrasonic flow meters. In those experiments, changes of pipe roughness result in the changes of PFs with certain errors. Therefore, we must take into account those effects in order to measure the flow rates of feedwater with better accuracy in actual power plants. (authors)

  9. Comparative analysis of diagnostic accuracy of different brain biopsy procedures.

    Science.gov (United States)

    Jain, Deepali; Sharma, Mehar Chand; Sarkar, Chitra; Gupta, Deepak; Singh, Manmohan; Mahapatra, A K

    2006-12-01

    Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different stereotactic and ultrasound-guided brain biopsy procedures. A retrospective analysis was conducted of all brain biopsies (frame-based and frameless stereotactic and ultrasound-guided) performed in a single tertiary care neurosciences center between 1995 and 2005. The overall diagnostic accuracy achieved on histopathology and correlation with type of biopsy technique was evaluated. A total of 130 cases were included, which consisted of 82 males and 48 females. Age ranged from 4 to 75 years (mean age 39.5 years). Twenty per cent (27 patients) were in the pediatric age group, while 12% (16 patients) were >or= 60-years of age. A definitive histological diagnosis was established in 109 cases (diagnostic yield 80.2%), which encompassed 101 neoplastic and eight nonneoplastic lesions. Frame-based, frameless stereotactic and ultrasound-guided biopsies were done in 95, 15 and 20 patients respectively. Although the numbers of cases were small there was trend for better yield with frameless image-guided stereotactic biopsy and maximum diagnostic yield was obtained i.e, 87% (13/15) in comparison to conventional frame-based CT-guided stereotactic biopsy and ultrasound-guided biopsy. Overall, a trend of higher diagnostic yield was seen in cases with frameless image-guided stereotactic biopsy. Thus, this small series confirms that frameless neuronavigator-guided stereotactic procedures represent the lesion sufficiently in order to make histopathologic diagnosis.

  10. Accuracy of a Wrist-Worn Heart Rate Sensing Device during Elective Pediatric Surgical Procedures

    Directory of Open Access Journals (Sweden)

    Gloria Pelizzo

    2018-03-01

    Full Text Available The reliability of wearable photoplethysmography (PPG sensors to measure heart rate (HR in hospitalized patients has only been demonstrated in adults. We evaluated the accuracy of HR monitoring with a personal fitness tracker (PFT in children undergoing surgery. HR monitoring was performed using a wrist-worn PFT (Fitbit Charge HR in 30 children (8.21 ± 3.09 years undergoing laparoscopy (n = 8 or open surgery (n = 22. HR values were analyzed preoperatively and during surgery. The accuracy of HR recordings was compared with measurements recorded during continuous electrocardiographic (cECG monitoring; HRs derived from continuous monitoring with pulse oximetry (SpO2R were used as a positive control. PFT-derived HR values were in agreement with those recorded during cECG (r = 0.99 and SpO2R (r = 0.99 monitoring. PFT performance remained high in children < 8 years (r = 0.99, with a weight < 30 kg (r = 0.99 and when the HR was < 70 beats per minute (bpm (r = 0.91 or > 140 bpm (r = 0.99. PFT accuracy was similar during laparoscopy and open surgery, as well as preoperatively and during the intervention (r > 0.9. PFT–derived HR showed excellent accuracy compared with HRs measured by cECG and SpO2R during pediatric surgical procedures. Further clinical evaluation is needed to define whether PFTs can be used in different health care settings.

  11. Effect of longitudinal profile on the seismic anaysis of concrete gravity dams

    International Nuclear Information System (INIS)

    El-Nady, A.; Ghobarah, A.; Aziz, T.S.

    1992-01-01

    The traditional three-dimensional analysis of concrete gravity dams is expensive and very difficult. An alternate approach is to divide the dam into substructures. Each monolith is considered as a substructure and its degrees of freedom are reduced to those on the contact surfaces with the adjacent monoliths as well as a few Ritz vectors. Using this procedure high accuracy was achieved using a reasonable number of degrees of freedom. The analysis is carried out in the frequency domain to account for the frequency dependent parameters in the reservoir substructure. The procedure was tested and compared to typical three-dimensional analysis and was found to give high accuracy. A simplified cross section of gravity dams with different longitudinal profiles was studied using the substructuring procedure as well as a typical two-dimensional analysis. The results obtained show a significant variation in dynamic properties of the dam from that calculated assuming two-dimensional analysis. Furthermore, the response of the dam varies significantly when including the effect of longitudinal profile of the structure. It is concluded that the two-dimensional representation of the structure may substantially overestimate the response of the dam, depending on its longitudinal profile, especially when keyed joints are used in the construction. 13 refs., 5 figs., 4 tabs

  12. Genomic GC-content affects the accuracy of 16S rRNA gene sequencing bsed microbial profiling due to PCR bias

    DEFF Research Database (Denmark)

    Laursen, Martin F.; Dalgaard, Marlene Danner; Bahl, Martin Iain

    2017-01-01

    Profiling of microbial community composition is frequently performed by partial 16S rRNA gene sequencing on benchtop platforms following PCR amplification of specific hypervariable regions within this gene. Accuracy and reproducibility of this strategy are two key parameters to consider, which may...... be influenced during all processes from sample collection and storage, through DNA extraction and PCR based library preparation to the final sequencing. In order to evaluate both the reproducibility and accuracy of 16S rRNA gene based microbial profiling using the Ion Torrent PGM platform, we prepared libraries...... be explained partly by premature read truncation, but to larger degree their genomic GC-content, which correlated negatively with the observed relative abundances, suggesting a PCR bias against GC-rich species during library preparation. Increasing the initial denaturation time during the PCR amplification...

  13. Evaluating Coding Accuracy in General Surgery Residents' Accreditation Council for Graduate Medical Education Procedural Case Logs.

    Science.gov (United States)

    Balla, Fadi; Garwe, Tabitha; Motghare, Prasenjeet; Stamile, Tessa; Kim, Jennifer; Mahnken, Heidi; Lees, Jason

    The Accreditation Council for Graduate Medical Education (ACGME) case log captures resident operative experience based on Current Procedural Terminology (CPT) codes and is used to track operative experience during residency. With increasing emphasis on resident operative experiences, coding is more important than ever. It has been shown in other surgical specialties at similar institutions that the residents' ACGME case log may not accurately reflect their operative experience. What barriers may influence this remains unclear. As the only objective measure of resident operative experience, an accurate case log is paramount in representing one's operative experience. This study aims to determine the accuracy of procedural coding by general surgical residents at a single institution. Data were collected from 2 consecutive graduating classes of surgical residents' ACGME case logs from 2008 to 2014. A total of 5799 entries from 7 residents were collected. The CPT codes entered by residents were compared to departmental billing records submitted by the attending surgeon for each procedure. Assigned CPT codes by institutional American Academy of Professional Coders certified abstract coders were considered the "gold standard." A total of 4356 (75.12%) of 5799 entries were identified in billing records. Excel 2010 and SAS 9.3 were used for analysis. In the event of multiple codes for the same patient, any match between resident codes and billing record codes was considered a "correct" entry. A 4-question survey was distributed to all current general surgical residents at our institution for feedback on coding habits, limitations to accurate coding, and opinions on ACGME case log representation of their operative experience. All 7 residents had a low percentage of correctly entered CPT codes. The overall accuracy proportion for all residents was 52.82% (range: 43.32%-60.07%). Only 1 resident showed significant improvement in accuracy during his/her training (p = 0

  14. Diagnostic accuracy of urinary prostate protein glycosylation profiling in prostatitis diagnosis.

    Science.gov (United States)

    Vermassen, Tijl; Van Praet, Charles; Poelaert, Filip; Lumen, Nicolaas; Decaestecker, Karel; Hoebeke, Piet; Van Belle, Simon; Rottey, Sylvie; Delanghe, Joris

    2015-01-01

    Although prostatitis is a common male urinary tract infection, clinical diagnosis of prostatitis is difficult. The developmental mechanism of prostatitis is not yet unraveled which led to the elaboration of various biomarkers. As changes in asparagine-linked-(N-)-glycosylation were observed between healthy volunteers (HV), patients with benign prostate hyperplasia and prostate cancer patients, a difference could exist in biochemical parameters and urinary N-glycosylation between HV and prostatitis patients. We therefore investigated if prostatic protein glycosylation could improve the diagnosis of prostatitis. Differences in serum and urine biochemical markers and in total urine N-glycosylation profile of prostatic proteins were determined between HV (N=66) and prostatitis patients (N=36). Additionally, diagnostic accuracy of significant biochemical markers and changes in N-glycosylation was assessed. Urinary white blood cell (WBC) count enabled discrimination of HV from prostatitis patients (Pprostatitis patients from HV (Pprostatitis patients compared to HV (Pprostatitis. Further research is required to unravel the developmental course of prostatic inflammation.

  15. Management and presentation of grouped procedures: has the IHE integration profile cracked the toughest radiology workflow nut?

    Science.gov (United States)

    Parisot, Charles R.; Channin, David S.; Avrin, David E.; Lindop, Christopher

    2001-08-01

    In a simple, typical radiology workflow process, an order generates a single procedure, which in turn generates a single data set, from which, one radiology report is generated. There are, however, occasions when a single order consists of more than one procedure each with a separate report, yet the procedures are accomplished by one physical acquisition of data. The prototypical example of this is the request for computed tomographic evaluation of the chest, abdomen and pelvis. The study is accomplished, with modern day scanners, by a single helical acquisition, yet there are typically three codable and billable procedures involved, and these may be reported independently either for administrative or academic reasons. This grouping of procedures remained up to now a challenge to automate across integrated modalities, PACS and RIS. This paper discusses a number of other practical cases where this situation occurs and reviews the capabilities of the Presentation of Grouped Procedures IHE Integration Profile in solving this problem. The DICOM services used are evaluated as well as the strengths and weaknesses of this IHE Integration Profile. The implementation experience gained on both a CT and an MR for the IHE Demonstration at RSNA 2000 and HIMSS 2001 is also reviewed. In conclusion, the resulting clinical and operational benefits are discussed.

  16. Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System.

    Science.gov (United States)

    Busse, Harald; Riedel, Tim; Garnov, Nikita; Thörmer, Gregor; Kahn, Thomas; Moche, Michael

    2015-01-01

    MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out") in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators. Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR) and resident radiologists (RR) as well as medical students (MS) - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm). Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0). Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81%) were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec) differed significantly (p<0.01). Mean overall rating was 4.2. The average operator would use the system again (4.8) and stated that the outcome justifies the extra effort (4.4). Lowest agreement was reported for the robustness against external perturbations (2.8). The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore) MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were

  17. Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System.

    Directory of Open Access Journals (Sweden)

    Harald Busse

    Full Text Available MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out" in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators.Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR and resident radiologists (RR as well as medical students (MS - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm. Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0.Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81% were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec differed significantly (p<0.01. Mean overall rating was 4.2. The average operator would use the system again (4.8 and stated that the outcome justifies the extra effort (4.4. Lowest agreement was reported for the robustness against external perturbations (2.8.The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were

  18. Increase in the accuracy of approximating the profile of the erosion zone in planar magnetrons

    Science.gov (United States)

    Rogov, A. V.; Kapustin, Yu. V.

    2017-09-01

    It has been shown that the use of the survival function of the Weibull distribution shifted along the ordinate axis allows one to increase the accuracy of the approximation of the normalized profile of an erosion zone in the area from the axis to the maximum sputtering region compared with the previously suggested distribution function of the extremum values. The survival function of the Weibull distribution is used in the area from the maximum to the outer boundary of an erosion zone. The major advantage of using the new approximation is observed for magnetrons with a large central nonsputtered spot and for magnetrons with substantial sputtering in the paraxial zone.

  19. Peaks, plateaus, numerical instabilities, and achievable accuracy in Galerkin and norm minimizing procedures for solving Ax=b

    Energy Technology Data Exchange (ETDEWEB)

    Cullum, J. [IBM T.J. Watson Research Center, Yorktown Heights, NY (United States)

    1994-12-31

    Plots of the residual norms generated by Galerkin procedures for solving Ax = b often exhibit strings of irregular peaks. At seemingly erratic stages in the iterations, peaks appear in the residual norm plot, intervals of iterations over which the norms initially increase and then decrease. Plots of the residual norms generated by related norm minimizing procedures often exhibit long plateaus, sequences of iterations over which reductions in the size of the residual norm are unacceptably small. In an earlier paper the author discussed and derived relationships between such peaks and plateaus within corresponding Galerkin/Norm Minimizing pairs of such methods. In this paper, through a set of numerical experiments, the author examines connections between peaks, plateaus, numerical instabilities, and the achievable accuracy for such pairs of iterative methods. Three pairs of methods, GMRES/Arnoldi, QMR/BCG, and two bidiagonalization methods are studied.

  20. Assessing accuracy of an electronic provincial medication repository

    Directory of Open Access Journals (Sweden)

    Price Morgan

    2012-05-01

    Full Text Available Abstract Background Jurisdictional drug information systems are being implemented in many regions around the world. British Columbia, Canada has had a provincial medication dispensing record, PharmaNet, system since 1995. Little is known about how accurately PharmaNet reflects actual medication usage. Methods This prospective, multi-centre study compared pharmacist collected Best Possible Medication Histories (BPMH to PharmaNet profiles to assess accuracy of the PharmaNet profiles for patients receiving a BPMH as part of clinical care. A review panel examined the anonymized BPMHs and discrepancies to estimate clinical significance of discrepancies. Results 16% of medication profiles were accurate, with 48% of the discrepant profiles considered potentially clinically significant by the clinical review panel. Cardiac medications tended to be more accurate (e.g. ramipril was accurate >90% of the time, while insulin, warfarin, salbutamol and pain relief medications were often inaccurate (80–85% of the time. 1215 sequential BPMHs were collected and reviewed for this study. Conclusions The PharmaNet medication repository has a low accuracy and should be used in conjunction with other sources for medication histories for clinical or research purposes. This finding is consistent with other, smaller medication repository accuracy studies in other jurisdictions. Our study highlights specific medications that tend to be lower in accuracy.

  1. Association and discrimination of diesel fuels using chemometric procedures.

    Science.gov (United States)

    Marshall, Lucas J; McIlroy, John W; McGuffin, Victoria L; Waddell Smith, Ruth

    2009-08-01

    Five neat diesel samples were analyzed by gas chromatography-mass spectrometry and total ion chromatograms as well as extracted ion profiles of the alkane and aromatic compound classes were generated. A retention time alignment algorithm was employed to align chromatograms prior to peak area normalization. Pearson product moment correlation coefficients and principal components analysis were then employed to investigate association and discrimination among the diesel samples. The same procedures were also used to investigate the association of a diesel residue to its neat counterpart. Current limitations in the retention time alignment algorithm and the subsequent effect on the association and discrimination of the diesel samples are discussed. An understanding of these issues is crucial to ensure the accuracy of data interpretation based on such chemometric procedures.

  2. Improvement of the decision efficiency of the accuracy profile by means of a desirability function for analytical methods validation. Application to a diacetyl-monoxime colorimetric assay used for the determination of urea in transdermal iontophoretic extracts.

    Science.gov (United States)

    Rozet, E; Wascotte, V; Lecouturier, N; Préat, V; Dewé, W; Boulanger, B; Hubert, Ph

    2007-05-22

    Validation of analytical methods is a widely used and regulated step for each analytical method. However, the classical approaches to demonstrate the ability to quantify of a method do not necessarily fulfill this objective. For this reason an innovative methodology was recently introduced by using the tolerance interval and accuracy profile, which guarantee that a pre-defined proportion of future measurements obtained with the method will be included within the acceptance limits. Accuracy profile is an effective decision tool to assess the validity of analytical methods. The methodology to build such a profile is detailed here. However, as for any visual tool it has a part of subjectivity. It was then necessary to make the decision process objective in order to quantify the degree of adequacy of an accuracy profile and to allow a thorough comparison between such profiles. To achieve this, we developed a global desirability index based on the three most important validation criteria: the trueness, the precision and the range. The global index allows the classification of the different accuracy profiles obtained according to their respective response functions. A diacetyl-monoxime colorimetric assay for the determination of urea in transdermal iontophoretic extracts was used to illustrate these improvements.

  3. Reproducibility of Automated Voice Range Profiles, a Systematic Literature Review

    DEFF Research Database (Denmark)

    Printz, Trine; Rosenberg, Tine; Godballe, Christian

    2018-01-01

    literature on test-retest accuracy of the automated voice range profile assessment. Study design: Systematic review. Data sources: PubMed, Scopus, Cochrane Library, ComDisDome, Embase, and CINAHL (EBSCO). Methods: We conducted a systematic literature search of six databases from 1983 to 2016. The following......Objective: Reliable voice range profiles are of great importance when measuring effects and side effects from surgery affecting voice capacity. Automated recording systems are increasingly used, but the reproducibility of results is uncertain. Our objective was to identify and review the existing...... keywords were used: phonetogram, voice range profile, and acoustic voice analysis. Inclusion criteria were automated recording procedure, healthy voices, and no intervention between test and retest. Test-retest values concerning fundamental frequency and voice intensity were reviewed. Results: Of 483...

  4. Comparison of Deep Brain Stimulation Lead Targeting Accuracy and Procedure Duration between 1.5- and 3-Tesla Interventional Magnetic Resonance Imaging Systems: An Initial 12-Month Experience.

    Science.gov (United States)

    Southwell, Derek G; Narvid, Jared A; Martin, Alastair J; Qasim, Salman E; Starr, Philip A; Larson, Paul S

    2016-01-01

    Interventional magnetic resonance imaging (iMRI) allows deep brain stimulator lead placement under general anesthesia. While the accuracy of lead targeting has been described for iMRI systems utilizing 1.5-tesla magnets, a similar assessment of 3-tesla iMRI procedures has not been performed. To compare targeting accuracy, the number of lead targeting attempts, and surgical duration between procedures performed on 1.5- and 3-tesla iMRI systems. Radial targeting error, the number of targeting attempts, and procedure duration were compared between surgeries performed on 1.5- and 3-tesla iMRI systems (SmartFrame and ClearPoint systems). During the first year of operation of each system, 26 consecutive leads were implanted using the 1.5-tesla system, and 23 consecutive leads were implanted using the 3-tesla system. There was no significant difference in radial error (Mann-Whitney test, p = 0.26), number of lead placements that required multiple targeting attempts (Fisher's exact test, p = 0.59), or bilateral procedure durations between surgeries performed with the two systems (p = 0.15). Accurate DBS lead targeting can be achieved with iMRI systems utilizing either 1.5- or 3-tesla magnets. The use of a 3-tesla magnet, however, offers improved visualization of the target structures and allows comparable accuracy and efficiency of placement at the selected targets. © 2016 S. Karger AG, Basel.

  5. How Do Different Ways of Measuring Individual Differences in Zero-Acquaintance Personality Judgment Accuracy Correlate With Each Other?

    Science.gov (United States)

    Hall, Judith A; Back, Mitja D; Nestler, Steffen; Frauendorfer, Denise; Schmid Mast, Marianne; Ruben, Mollie A

    2018-04-01

    This research compares two different approaches that are commonly used to measure accuracy of personality judgment: the trait accuracy approach wherein participants discriminate among targets on a given trait, thus making intertarget comparisons, and the profile accuracy approach wherein participants discriminate between traits for a given target, thus making intratarget comparisons. We examined correlations between these methods as well as correlations among accuracies for judging specific traits. The present article documents relations among these approaches based on meta-analysis of five studies of zero-acquaintance impressions of the Big Five traits. Trait accuracies correlated only weakly with overall and normative profile accuracy. Substantial convergence between the trait and profile accuracy methods was only found when an aggregate of all five trait accuracies was correlated with distinctive profile accuracy. Importantly, however, correlations between the trait and profile accuracy approaches were reduced to negligibility when statistical overlap was corrected by removing the respective trait from the profile correlations. Moreover, correlations of the separate trait accuracies with each other were very weak. Different ways of measuring individual differences in personality judgment accuracy are not conceptually and empirically the same, but rather represent distinct abilities that rely on different judgment processes. © 2017 Wiley Periodicals, Inc.

  6. Accuracy of a Classical Test Theory-Based Procedure for Estimating the Reliability of a Multistage Test. Research Report. ETS RR-17-02

    Science.gov (United States)

    Kim, Sooyeon; Livingston, Samuel A.

    2017-01-01

    The purpose of this simulation study was to assess the accuracy of a classical test theory (CTT)-based procedure for estimating the alternate-forms reliability of scores on a multistage test (MST) having 3 stages. We generated item difficulty and discrimination parameters for 10 parallel, nonoverlapping forms of the complete 3-stage test and…

  7. Conductivity Profile Determination by Eddy Current for Shot Peened Superalloy Surfaces Toward Residual Stress Assessment

    International Nuclear Information System (INIS)

    Shen, Y.; Lo, C. C. H.; Frishman, A. M.; Lee, C.; Nakagawa, N.

    2007-01-01

    This paper describes an eddy current model-based method for inverting near-surface conductivity deviation profiles of surface treated materials from swept-high frequency eddy current (SHFEC) data. This work forms part of our current research directed towards the development of an electromagnetic nondestructive technique for assessing residual stress of shot-peened superalloy components. The inversion procedure is based on the use of a parameterized function to describe the near-surface conductivity as a function of depth for a shot-peened surface, and the laterally uniform multi-layer theory of Cheng, Dodd and Deeds to calculate the resulting coil impedance deviations. The convergence of the inversion procedure has been tested against synthesized eddy current data. As a demonstration, the conductivity deviation profiles of a series of Inconel 718 specimens, shot peened at various Almen intensities, have been obtained by inversion. Several consistency tests were conducted to examine the reliability of the inverted conductivity profiles. The results show that conductivity deviation profiles can be reliably determined from SHFEC data within the accuracy of the current measurement system

  8. Demand Forecasting: An Evaluation of DODs Accuracy Metric and Navys Procedures

    Science.gov (United States)

    2016-06-01

    dataset ci = unit cost for item i fi = demand forecast for item i 28 ai = actual demand for item i A close look at fCIMIP metric reveals a...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA MBA PROFESSIONAL REPORT DEMAND FORECASTING : AN EVALUATION OF DOD’S ACCURACY...June 2016 3. REPORT TYPE AND DATES COVERED MBA professional report 4. TITLE AND SUBTITLE DEMAND FORECASTING : AN EVALUATION OF DOD’S ACCURACY

  9. A novel non-contact profiler design for measuring synchrotron radiation mirrors

    International Nuclear Information System (INIS)

    Lin, Yao; Takacs, P.Z.; Furenlid, K.; DeBiasse, R.A.; Wang, Run-Wen

    1990-08-01

    A novel optical profiler is described in this paper for measurement of surface profiles of synchrotron radiation (SR) mirrors. The measurement is based on a combination of an optical heterodyne technique and a precise phase measurement procedure without a reference surface. A Zeeman two-frequency He-Ne laser is employed as the light source. The common-path optical system, which uses a birefringent lens as the beam splitter, minimizes the effects of air turbulence, sample vibration and temperature variation. A special autofocus system allows the profiler to measure the roughness and shape of a sample surface. The optical system is mounted on a large linear air-bearing slide, and is capable of scanning over distances covering the spatial period range from several microns to nearly one meter with a high measurement accuracy. 9 refs., 5 figs

  10. Relationship between the COI test and other sensory profiles by statistical procedures

    Directory of Open Access Journals (Sweden)

    Calvente, J. J.

    1994-04-01

    Full Text Available Relationships between 139 sensory attributes evaluated on 32 samples of virgin olive oil have been analysed by a statistical sensory wheel that guarantees the objectiveness and prediction of its conclusions concerning the best clusters of attributes: green, bitter-pungent, ripe fruit, fruity, sweet fruit, undesirable attributes and two miscellanies. The procedure allows the sensory notes evaluated for potential consumers of this edible oil from the point of view of its habitual consumers to be understood with special reference to The European Communities Regulation n-2568/91. Five different panels: Spanish, Greek, Italian, Dutch and British, have been used to evaluate the samples. Analysis of the relationships between stimuli perceived by aroma, flavour, smell, mouthfeel and taste together with Linear Sensory Profiles based on Fuzzy Logic are provided. A 3-dimensional plot indicates the usefulness of the proposed procedure in the authentication of different varieties of virgin olive oil. An analysis of the volatile compounds responsible for most of the attributes gives weight to the conclusions. Directions which promise to improve the E.G. Regulation on the sensory quality of olive oil are also given.

  11. SU-E-T-432: A Rapid and Comprehensive Procedure for Daily Proton QA

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, T; Sun, B; Grantham, K; Knutson, N; Santanam, L; Goddu, S; Klein, E [Washington University, St. Louis, MO (United States)

    2014-06-01

    Purpose: The objective is to develop a rapid and comprehensive daily QA procedure implemented at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. Methods: A scribed phantom with imbedded fiducials is used for checking lasers accuracy followed by couch isocentricity and for X-ray imaging congruence with isocenter. A Daily QA3 device (Sun Nuclear, FL) was used to check output, range and profiles. Five chambers in the central region possess various build-ups. After converting the thickness of the inherent build-ups into water equivalent thickness (WET) for proton, range of any beam can be checked with additional build-up on the Daily QA3 device. In our procedure, 3 beams from 3 bands (large, small and deep) with nominal range of 20 cm are checked daily. 17cm plastic water with WET of 16.92cm are used as additional build-up so that four chambers sit on the SOBP plateau at various depths and one sit on the distal fall off. Reading from the five chambers are fitted to an error function that has been parameterized to match the SOBP with the same nominal range. Shifting of the error function to maximize the correlation between measurements and the error function is deemed as the range shift from the nominal value. Results: We have found couch isocentricity maintained over 180 degrees. Imaging system exhibits accuracy in regard to imaging and mechanical isocenters. Ranges are within 1mm accuracy from measurements in water tank, and sensitive to change of sub-millimeter. Data acquired since the start of operation show outputs, profiles and range stay within 1% or 1mm from baselines. The whole procedure takes about 40 minutes. Conclusion: Taking advantage of the design of Daily QA3 device turns the device originally designed for photon and electron into a comprehensive and rapid tool for proton daily QA.

  12. SU-E-T-432: A Rapid and Comprehensive Procedure for Daily Proton QA

    International Nuclear Information System (INIS)

    Zhao, T; Sun, B; Grantham, K; Knutson, N; Santanam, L; Goddu, S; Klein, E

    2014-01-01

    Purpose: The objective is to develop a rapid and comprehensive daily QA procedure implemented at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. Methods: A scribed phantom with imbedded fiducials is used for checking lasers accuracy followed by couch isocentricity and for X-ray imaging congruence with isocenter. A Daily QA3 device (Sun Nuclear, FL) was used to check output, range and profiles. Five chambers in the central region possess various build-ups. After converting the thickness of the inherent build-ups into water equivalent thickness (WET) for proton, range of any beam can be checked with additional build-up on the Daily QA3 device. In our procedure, 3 beams from 3 bands (large, small and deep) with nominal range of 20 cm are checked daily. 17cm plastic water with WET of 16.92cm are used as additional build-up so that four chambers sit on the SOBP plateau at various depths and one sit on the distal fall off. Reading from the five chambers are fitted to an error function that has been parameterized to match the SOBP with the same nominal range. Shifting of the error function to maximize the correlation between measurements and the error function is deemed as the range shift from the nominal value. Results: We have found couch isocentricity maintained over 180 degrees. Imaging system exhibits accuracy in regard to imaging and mechanical isocenters. Ranges are within 1mm accuracy from measurements in water tank, and sensitive to change of sub-millimeter. Data acquired since the start of operation show outputs, profiles and range stay within 1% or 1mm from baselines. The whole procedure takes about 40 minutes. Conclusion: Taking advantage of the design of Daily QA3 device turns the device originally designed for photon and electron into a comprehensive and rapid tool for proton daily QA

  13. Accuracy improvement of irradiation data by combining ground and satellite measurements

    Energy Technology Data Exchange (ETDEWEB)

    Betcke, J. [Energy and Semiconductor Research Laboratory, Carl von Ossietzky University, Oldenburg (Germany); Beyer, H.G. [Department of Electrical Engineering, University of Applied Science (F.H.) Magdeburg-Stendal, Magdeburg (Germany)

    2004-07-01

    Accurate and site-specific irradiation data are essential input for optimal planning, monitoring and operation of solar energy technologies. A concrete example is the performance check of grid connected PV systems with the PVSAT-2 procedure. This procedure detects system faults in an early stage by a daily comparison of an individual reference yield with the actual yield. Calculation of the reference yield requires hourly irradiation data with a known accuracy. A field test of the predecessing PVSAT-1 procedure showed that the accuracy of the irradiation input is the determining factor for the overall accuracy of the yield calculation. In this paper we will investigate if it is possible to improve the accuracy of sitespeci.c irradiation data by combining accurate localised pyranometer data with semi-continuous satellite data.We will therefore introduce the ''Kriging of Differences'' data fusion method. Kriging of Differences also offers the possibility to estimate it's own accuracy. The obtainable accuracy gain and the effectiveness of the accuracy prediction will be investigated by validation on monthly and daily irradiation datasets. Results will be compared with the Heliosat method and interpolation of ground data. (orig.)

  14. Biogeochemical sensor performance in the SOCCOM profiling float array

    Science.gov (United States)

    Johnson, Kenneth S.; Plant, Joshua N.; Coletti, Luke J.; Jannasch, Hans W.; Sakamoto, Carole M.; Riser, Stephen C.; Swift, Dana D.; Williams, Nancy L.; Boss, Emmanuel; Haëntjens, Nils; Talley, Lynne D.; Sarmiento, Jorge L.

    2017-08-01

    The Southern Ocean Carbon and Climate Observations and Modeling (SOCCOM) program has begun deploying a large array of biogeochemical sensors on profiling floats in the Southern Ocean. As of February 2016, 86 floats have been deployed. Here the focus is on 56 floats with quality-controlled and adjusted data that have been in the water at least 6 months. The floats carry oxygen, nitrate, pH, chlorophyll fluorescence, and optical backscatter sensors. The raw data generated by these sensors can suffer from inaccurate initial calibrations and from sensor drift over time. Procedures to correct the data are defined. The initial accuracy of the adjusted concentrations is assessed by comparing the corrected data to laboratory measurements made on samples collected by a hydrographic cast with a rosette sampler at the float deployment station. The long-term accuracy of the corrected data is compared to the GLODAPv2 data set whenever a float made a profile within 20 km of a GLODAPv2 station. Based on these assessments, the fleet average oxygen data are accurate to 1 ± 1%, nitrate to within 0.5 ± 0.5 µmol kg-1, and pH to 0.005 ± 0.007, where the error limit is 1 standard deviation of the fleet data. The bio-optical measurements of chlorophyll fluorescence and optical backscatter are used to estimate chlorophyll a and particulate organic carbon concentration. The particulate organic carbon concentrations inferred from optical backscatter appear accurate to with 35 mg C m-3 or 20%, whichever is larger. Factors affecting the accuracy of the estimated chlorophyll a concentrations are evaluated.Plain Language SummaryThe ocean science community must move toward greater use of autonomous platforms and sensors if we are to extend our knowledge of the effects of climate driven change within the ocean. Essential to this shift in observing strategies is an understanding of the performance that can be obtained from biogeochemical sensors on platforms deployed for years and the

  15. Assessing the Accuracy of Quantitative Molecular Microbial Profiling

    Directory of Open Access Journals (Sweden)

    Denise M. O'Sullivan

    2014-11-01

    Full Text Available The application of high-throughput sequencing in profiling microbial communities is providing an unprecedented ability to investigate microbiomes. Such studies typically apply one of two methods: amplicon sequencing using PCR to target a conserved orthologous sequence (typically the 16S ribosomal RNA gene or whole (metagenome sequencing (WGS. Both methods have been used to catalog the microbial taxa present in a sample and quantify their respective abundances. However, a comparison of the inherent precision or bias of the different sequencing approaches has not been performed. We previously developed a metagenomic control material (MCM to investigate error when performing different sequencing strategies. Amplicon sequencing using four different primer strategies and two 16S rRNA regions was examined (Roche 454 Junior and compared to WGS (Illumina HiSeq. All sequencing methods generally performed comparably and in good agreement with organism specific digital PCR (dPCR; WGS notably demonstrated very high precision. Where discrepancies between relative abundances occurred they tended to differ by less than twofold. Our findings suggest that when alternative sequencing approaches are used for microbial molecular profiling they can perform with good reproducibility, but care should be taken when comparing small differences between distinct methods. This work provides a foundation for future work comparing relative differences between samples and the impact of extraction methods. We also highlight the value of control materials when conducting microbial profiling studies to benchmark methods and set appropriate thresholds.

  16. Assimilation of Atmospheric InfraRed Sounder (AIRS) Profiles using WRF-Var

    Science.gov (United States)

    Zavodsky, Brad; Jedlovec, Gary J.; Lapenta, William

    2008-01-01

    The Weather Research and Forecasting (WRF) model contains a three-dimensional variational (3DVAR) assimilation system (WRF-Var), which allows a user to join data from multiple sources into one coherent analysis. WRF-Var combines observations with a background field traditionally generated using a previous model forecast through minimization of a cost function. In data sparse regions, remotely-sensed observations may be able to improve analyses and produce improved forecasts. One such source comes from the Atmospheric Infrared Sounder (AIRS), which together with the Advanced Microwave Sounding Unit (AMSU), represents one of the most advanced space-based atmospheric sounding systems. The combined AIRS/AMSU system provides radiance measurements used as input to a sophisticated retrieval scheme which has been shown to produce temperature profiles with an accuracy of 1 K over 1 km layers and humidity profiles with accuracy of 15% in 2 km layers in both clear and partly cloudy conditions. The retrieval algorithm also provides estimates of the accuracy of the retrieved values at each pressure level, allowing the user to select profiles based on the required error tolerances of the application. The purpose of this paper is to describe a procedure to optimally assimilate high-resolution AIRS profile data into a regional configuration of the Advanced Research WRF (ARW) version 2.2 using WRF-Var. The paper focuses on development of background error covariances for the regional domain and background field type using gen_be and an optimal methodology for ingesting AIRS temperature and moisture profiles as separate overland and overwater retrievals with different error characteristics in the WRF-Var. The AIRS thermodynamic profiles are obtained from the version 5.0 Earth Observing System (EOS) science team retrieval algorithm and contain information about the quality of each temperature layer. The quality indicators are used to select the highest quality temperature and moisture

  17. Extrinsic factors affecting accuracy of ultrasonic flowmeters for LMFBRs

    International Nuclear Information System (INIS)

    Managan, W.W.

    1976-08-01

    Assuming that ultrasonic flowmeters of suitable intrinsic accuracy are feasible, this report explores factors extrinsic to the flowmeter which affect the accuracy such as asymmetric flow profile, regions of high turbulence and thermal stratification. By integrating isovelocity flow profile maps, the predicted performance of various flowmeter configurations may be compared to experimental data. For the two pipe arrangements analyzed, the single diametral path flowmeter results were within 5 percent of true flow rate. Theoretical correction factors could reduce the error for the straight pipe but increased the error for asymmetrical flow. On the same pipe arrangements a four path ultrasonic flowmeter spaced for Gaussian integration gave less than 1 percent error. For more general conclusions a range of flow profiles produced by typical LMFBR piping arrangements must be analyzed

  18. Surgical accuracy of three-dimensional virtual planning

    DEFF Research Database (Denmark)

    Stokbro, Kasper; Aagaard, Esben; Torkov, Peter

    2016-01-01

    This retrospective study evaluated the precision and positional accuracy of different orthognathic procedures following virtual surgical planning in 30 patients. To date, no studies of three-dimensional virtual surgical planning have evaluated the influence of segmentation on positional accuracy...... and transverse expansion. Furthermore, only a few have evaluated the precision and accuracy of genioplasty in placement of the chin segment. The virtual surgical plan was compared with the postsurgical outcome by using three linear and three rotational measurements. The influence of maxillary segmentation...

  19. Quality controls for wind measurement of a 1290-MHz boundary layer profiler under strong wind conditions.

    Science.gov (United States)

    Liu, Zhao; Zheng, Chaorong; Wu, Yue

    2017-09-01

    Wind profilers have been widely adopted to observe the wind field information in the atmosphere for different purposes. But accuracy of its observation has limitations due to various noises or disturbances and hence need to be further improved. In this paper, the data measured under strong wind conditions, using a 1290-MHz boundary layer profiler (BLP), are quality controlled via a composite quality control (QC) procedure proposed by the authors. Then, through the comparison with the data measured by radiosonde flights (balloon observations), the critical thresholds in the composite QC procedure, including consensus average threshold T 1 and vertical shear threshold T 3 , are systematically discussed. And the performance of the BLP operated under precipitation is also evaluated. It is found that to ensure the high accuracy and high data collectable rate, the optimal range of subsets is determined to be 4 m/s. Although the number of data rejected by the combined algorithm of vertical shear examination and small median test is quite limited, it is proved that the algorithm is quite useful to recognize the outlier with a large discrepancy. And the optimal wind shear threshold T 3 can be recommended as 5 ms -1 /100m. During patchy precipitation, the quality of data measured by the four oblique beams (using the DBS measuring technique) can still be ensured. After the BLP data are quality controlled by the composite QC procedure, the output can show good agreement with the balloon observation.

  20. Accuracy and safety of ward based pleural ultrasound in the Australian healthcare system.

    Science.gov (United States)

    Hammerschlag, Gary; Denton, Matthew; Wallbridge, Peter; Irving, Louis; Hew, Mark; Steinfort, Daniel

    2017-04-01

    Ultrasound has been shown to improve the accuracy and safety of pleural procedures. Studies to date have been performed in large, specialized units, where pleural procedures are performed by a small number of highly specialized physicians. There are no studies examining the safety and accuracy of ultrasound in the Australian healthcare system where procedures are performed by junior doctors with a high staff turnover. We performed a retrospective review of the ultrasound database in the Respiratory Department at the Royal Melbourne Hospital to determine accuracy and complications associated pleural procedures. A total of 357 ultrasounds were performed between October 2010 and June 2013. Accuracy of pleural procedures was 350 of 356 (98.3%). Aspiration of pleural fluid was successful in 121 of 126 (96%) of patients. Two (0.9%) patients required chest tube insertion for management of pneumothorax. There were no recorded pleural infections, haemorrhage or viscera puncture. Ward-based ultrasound for pleural procedures is safe and accurate when performed by appropriately trained and supported junior medical officers. Our findings support this model of pleural service care in the Australian healthcare system. © 2016 Asian Pacific Society of Respirology.

  1. Assessment Of Accuracies Of Remote-Sensing Maps

    Science.gov (United States)

    Card, Don H.; Strong, Laurence L.

    1992-01-01

    Report describes study of accuracies of classifications of picture elements in map derived by digital processing of Landsat-multispectral-scanner imagery of coastal plain of Arctic National Wildlife Refuge. Accuracies of portions of map analyzed with help of statistical sampling procedure called "stratified plurality sampling", in which all picture elements in given cluster classified in stratum to which plurality of them belong.

  2. Investigation of accuracy and computation time of a hierarchy of growth rate definitions

    International Nuclear Information System (INIS)

    Maudlin, P.J.; Borg, R.C.; Ott, K.O.

    1977-07-01

    A numerical illustration of the hierarchy of four logically different procedures for the calculation of the asymptotic growth of fast breeder fuel is presented. Each hierarchy level is analyzed in terms of accuracy and computational effort. Using the first procedure as reference, the fourth procedure, which incorporates the isotopic breeding worths, w vector*, requires a minimum amount of effort with a negligible decrease in accuracy

  3. Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Rettmann, Maryam E., E-mail: rettmann.maryam@mayo.edu; Holmes, David R.; Camp, Jon J.; Cameron, Bruce M.; Robb, Richard A. [Biomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905 (United States); Kwartowitz, David M. [Department of Bioengineering, Clemson University, Clemson, South Carolina 29634 (United States); Gunawan, Mia [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington D.C. 20057 (United States); Johnson, Susan B.; Packer, Douglas L. [Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905 (United States); Dalegrave, Charles [Clinical Cardiac Electrophysiology, Cardiology Division Hospital Sao Paulo, Federal University of Sao Paulo, 04024-002 Brazil (Brazil); Kolasa, Mark W. [David Grant Medical Center, Fairfield, California 94535 (United States)

    2014-02-15

    Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved

  4. Windowed multipole sensitivity to target accuracy of the optimization procedure

    International Nuclear Information System (INIS)

    Josey, Colin; Forget, Benoit; Smith, Kord

    2015-01-01

    This paper compares the accuracy of the windowed multipole direct Doppler broadening method to that of the ENDF-B/VII.1 libraries that come with MCNP6. Various windowed multipole libraries were generated with different maximum allowed relative errors. Then, the libraries were compared to the MCNP6 data via resonance integral and through single assembly Monte Carlo analysis. Since the windowed multipole uses resonance parameters, resonance integrals are only affected by the number of resonances included in the library and not by the order of the background fitting function. The relative performance of each library with varying maximum allowed error was evaluated. It was found that setting a maximum target relative error of 0.1% in the library provided highly accurate data that closely matches the MCNP6 data for all temperatures of interest, while still having suitable computational performance. Additionally, a library with a maximum relative error of 1% also provided reasonable accuracy on eigenvalue and reaction rates with a noticeable improvement on performance, but with a few statistically significant differences with the MCNP6 data. (author)

  5. Fitting the IRI F2-profile function to measured profiles

    International Nuclear Information System (INIS)

    Reinisch, B.W.; Huang Xueqin

    1997-01-01

    Comparison with profile data from ionosondes shows that the IRI bottomside F2-profiles can be improved by using better B0 and B1 parameters. The best parameters (in a least-squares sense) can be easily calculated in a numerical procedure from measured profiles presented as a sum of Chebyshev polynomials. 7 refs, 5 figs, 1 tab

  6. Knowing where is different from knowing what: Distinct response time profiles and accuracy effects for target location, orientation, and color probability.

    Science.gov (United States)

    Jabar, Syaheed B; Filipowicz, Alex; Anderson, Britt

    2017-11-01

    When a location is cued, targets appearing at that location are detected more quickly. When a target feature is cued, targets bearing that feature are detected more quickly. These attentional cueing effects are only superficially similar. More detailed analyses find distinct temporal and accuracy profiles for the two different types of cues. This pattern parallels work with probability manipulations, where both feature and spatial probability are known to affect detection accuracy and reaction times. However, little has been done by way of comparing these effects. Are probability manipulations on space and features distinct? In a series of five experiments, we systematically varied spatial probability and feature probability along two dimensions (orientation or color). In addition, we decomposed response times into initiation and movement components. Targets appearing at the probable location were reported more quickly and more accurately regardless of whether the report was based on orientation or color. On the other hand, when either color probability or orientation probability was manipulated, response time and accuracy improvements were specific for that probable feature dimension. Decomposition of the response time benefits demonstrated that spatial probability only affected initiation times, whereas manipulations of feature probability affected both initiation and movement times. As detection was made more difficult, the two effects further diverged, with spatial probability disproportionally affecting initiation times and feature probability disproportionately affecting accuracy. In conclusion, all manipulations of probability, whether spatial or featural, affect detection. However, only feature probability affects perceptual precision, and precision effects are specific to the probable attribute.

  7. The High Accuracy Measurement of CO2 Mixing Ratio Profiles Using Ground Based 1.6 μm CO2-DIAL with Temperature Measurement Techniques in the Lower-Atmosphere

    Science.gov (United States)

    Abo, M.; Shibata, Y.; Nagasawa, C.

    2017-12-01

    We have developed a ground based direct detection three-wavelength 1.6 μm differential absorption lidar (DIAL) to achieve measurements of vertical CO2 concentration and temperature profiles in the atmosphere. As the spectra of absorption lines of any molecules are influenced basically by the temperature and pressure in the atmosphere, it is important to measure them simultaneously so that the better accuracy of the DIAL measurement is realized. Conventionally, we have obtained the vertical profile of absorption cross sections using the atmospheric temperature profile by the objective analysis and the atmospheric pressure profile calculated by the pressure height equation. Comparison of atmospheric pressure profiles calculated from this equation and those obtained from radiosonde observations at Tateno, Japan is consistent within 0.2 % below 3 km altitude. But the temperature dependency of the CO2 density is 0.25 %/°C near the surface. Moreover, the CO2 concentration is often evaluated by the mixing ratio. Because the air density is related by the ideal gas law, the mixing ratio is also related by the atmospheric temperature. Therefore, the temperature affects not only accuracy of CO2 concentration but the CO2 mixing ratio. In this paper, some experimental results of the simultaneous measurement of atmospheric temperature profiles and CO2 mixing ratio profiles are reported from 0.4 to 2.5 km altitude using the three-wavelength 1.6 μm DIAL system. Temperature profiles of CO2 DIAL measurement were sometimes different from those of objective analysis below 1.5 km altitude. These differences are considered to be due to regionality at the lidar site. The temperature difference of 5.0 °C corresponds to a CO2 mixing ratio difference of 8.0 ppm at 500 m altitude. This cannot be ignored in estimates of regional sources and sinks of CO2. This three-wavelength CO2 DIAL technique can estimate accurately temporal behavior of CO2 mixing ratio profiles in the lower atmosphere

  8. Electron momentum density and Compton profile by a semi-empirical approach

    Science.gov (United States)

    Aguiar, Julio C.; Mitnik, Darío; Di Rocco, Héctor O.

    2015-08-01

    Here we propose a semi-empirical approach to describe with good accuracy the electron momentum densities and Compton profiles for a wide range of pure crystalline metals. In the present approach, we use an experimental Compton profile to fit an analytical expression for the momentum densities of the valence electrons. This expression is similar to a Fermi-Dirac distribution function with two parameters, one of which coincides with the ground state kinetic energy of the free-electron gas and the other resembles the electron-electron interaction energy. In the proposed scheme conduction electrons are neither completely free nor completely bound to the atomic nucleus. This procedure allows us to include correlation effects. We tested the approach for all metals with Z=3-50 and showed the results for three representative elements: Li, Be and Al from high-resolution experiments.

  9. Cognitive processes in criminal profile construction: a preliminary study.

    Science.gov (United States)

    Kocsis, Richard N; Middledorp, Jenny; Try, Andrew C

    2005-12-01

    This study undertook an empirically based examination of the cognitive processes associated with the accurate construction of a criminal psychological profile. This was accomplished by comparing the abilities of profilers and nonprofilers in two simulated profiling exercises that measured both profile accuracy and an individual's performance on various tests of memory and comprehension related to the case materials presented in each exercise. The results of these experiments suggest that an incremental relationship exists between comprehension of the case materials and accuracy of the profiles generated. In addition, the findings provide some tentative indications that the comprehension of case material in a narrative (i.e., written) format is an integral cognitive function to proficient profiling.

  10. Accuracy of a computed tomography scanning procedure to manufacture digital models.

    NARCIS (Netherlands)

    Darroudi, A.M.; Kuijpers-Jagtman, A.M.; Ongkosuwito, E.M.; Suttorp, C.M.; Bronkhorst, E.M.; Breuning, K.H.

    2017-01-01

    INTRODUCTION: Accurate articulation of the digital dental casts is crucial in orthodontic diagnosis and treatment planning. We aimed to determine the accuracy of manufacturing digital dental casts from computed tomography scanning of plaster casts regarding linear dimensions and interarch

  11. Cracking the code: the accuracy of coding shoulder procedures and the repercussions.

    Science.gov (United States)

    Clement, N D; Murray, I R; Nie, Y X; McBirnie, J M

    2013-05-01

    Coding of patients' diagnosis and surgical procedures is subject to error levels of up to 40% with consequences on distribution of resources and financial recompense. Our aim was to explore and address reasons behind coding errors of shoulder diagnosis and surgical procedures and to evaluate a potential solution. A retrospective review of 100 patients who had undergone surgery was carried out. Coding errors were identified and the reasons explored. A coding proforma was designed to address these errors and was prospectively evaluated for 100 patients. The financial implications were also considered. Retrospective analysis revealed the correct primary diagnosis was assigned in 54 patients (54%) had an entirely correct diagnosis, and only 7 (7%) patients had a correct procedure code assigned. Coders identified indistinct clinical notes and poor clarity of procedure codes as reasons for errors. The proforma was significantly more likely to assign the correct diagnosis (odds ratio 18.2, p code (odds ratio 310.0, p coding department. High error levels for coding are due to misinterpretation of notes and ambiguity of procedure codes. This can be addressed by allowing surgeons to assign the diagnosis and procedure using a simplified list that is passed directly to coding.

  12. Dissolution profiles of perindopril and indapamide in their fixed-dose formulations by a new HPLC method and different mathematical approaches

    Directory of Open Access Journals (Sweden)

    Gumieniczek Anna

    2015-09-01

    Full Text Available A new HPLC method was introduced and validated for simultaneous determination of perindopril and indapamide. Validation procedure included specificity, sensitivity, robustness, stability, linearity, precision and accuracy. The method was used for the dissolution test of perindopril and indapamide in three fixed-dose formulations. The dissolution procedure was optimized using different media, different pH of the buffer, surfactants, paddle speed and temperature. Similarity of dissolution profiles was estimated using different model-independent and model-dependent methods and, additionally, by principal component analysis (PCA. Also, some kinetic models were checked for dissolved amounts of drugs as a function of time.

  13. Local flow management/profile descent algorithm. Fuel-efficient, time-controlled profiles for the NASA TSRV airplane

    Science.gov (United States)

    Groce, J. L.; Izumi, K. H.; Markham, C. H.; Schwab, R. W.; Thompson, J. L.

    1986-01-01

    The Local Flow Management/Profile Descent (LFM/PD) algorithm designed for the NASA Transport System Research Vehicle program is described. The algorithm provides fuel-efficient altitude and airspeed profiles consistent with ATC restrictions in a time-based metering environment over a fixed ground track. The model design constraints include accommodation of both published profile descent procedures and unpublished profile descents, incorporation of fuel efficiency as a flight profile criterion, operation within the performance capabilities of the Boeing 737-100 airplane with JT8D-7 engines, and conformity to standard air traffic navigation and control procedures. Holding and path stretching capabilities are included for long delay situations.

  14. Neuronavigation accuracy dependence on CT and MR imaging parameters: a phantom-based study

    International Nuclear Information System (INIS)

    Poggi, S; Pallotta, S; Russo, S; Gallina, P; Torresin, A; Bucciolini, M

    2003-01-01

    Clinical benefits from neuronavigation are well established. However, the complexity of its technical environment requires a careful evaluation of different types of errors. In this work, a detailed phantom study which investigates the accuracy in a neuronavigation procedure is presented. The dependence on many different imaging parameters, such as field of view, slice thickness and different kind of sequences (sequential and spiral for CT, T1-weighted and T2-weighted for MRI), is quantified. Moreover, data based on CT images are compared to those based on MR images, taking into account MRI distortion. Finally, the contributions to global accuracy coming from image acquisition, registration and navigation itself are discussed. Results demonstrate the importance of imaging accuracy. Procedures based on CT proved to be more accurate than procedures based on MRI. In the former, values from 2 to 2.5 mm are obtained for 95% fractiles of cumulative distribution of Euclidean distances between the intended target and the reached one while, in the latter, the measured values range from 3 to 4 mm. The absence of imaging distortion proved to be crucial for registration accuracy in MR-based procedures

  15. Risk Profiles for Endometriosis in Japanese Women: Results From a Repeated Survey of Self-Reports

    Science.gov (United States)

    Yasui, Toshiyuki; Hayashi, Kunihiko; Nagai, Kazue; Mizunuma, Hideki; Kubota, Toshiro; Lee, Jung-Su; Suzuki, Shosuke

    2015-01-01

    Background The prevalence and risk factors for endometriosis may differ according to diagnosis methodologies, such as study populations and diagnostic accuracy. We examined risk profiles in imaging-diagnosed endometriosis with and without surgical confirmation in a large population of Japanese women, as well as the differences in risk profiles of endometriosis based on history of infertility. Methods Questionnaires that included items on sites of endometriosis determined by imaging techniques and surgical procedure were mailed to 1025 women who self-reported endometriosis in a baseline survey of the Japan Nurses’ Health Study (n = 15 019). Results Two hundred and ten women had surgically confirmed endometriosis (Group A), 120 had imaging-diagnosed endometriosis without a surgical procedure (Group B), and 264 had adenomyosis (Group C). A short menstrual cycle at 18–22 years of age and cigarette smoking at 30 years of age were associated with significantly increased risk of endometriosis (Group A plus Group B), while older age was associated with risk of adenomyosis (Group C). In women with a history of infertility, a short menstrual cycle was associated with a significantly increased risk of endometriosis in both Group A and Group B, but risk profiles of endometriosis were different between Group A and Group B in women without a history of infertility. Conclusions Women with surgically confirmed endometriosis and those with imaging-diagnosed endometriosis without surgery have basically common risk profiles, but these risk profiles are different from those with adenomyosis. The presence of a history of infertility should be taken into consideration for evaluation of risk profiles. PMID:25716280

  16. Systematic review of discharge coding accuracy

    Science.gov (United States)

    Burns, E.M.; Rigby, E.; Mamidanna, R.; Bottle, A.; Aylin, P.; Ziprin, P.; Faiz, O.D.

    2012-01-01

    Introduction Routinely collected data sets are increasingly used for research, financial reimbursement and health service planning. High quality data are necessary for reliable analysis. This study aims to assess the published accuracy of routinely collected data sets in Great Britain. Methods Systematic searches of the EMBASE, PUBMED, OVID and Cochrane databases were performed from 1989 to present using defined search terms. Included studies were those that compared routinely collected data sets with case or operative note review and those that compared routinely collected data with clinical registries. Results Thirty-two studies were included. Twenty-five studies compared routinely collected data with case or operation notes. Seven studies compared routinely collected data with clinical registries. The overall median accuracy (routinely collected data sets versus case notes) was 83.2% (IQR: 67.3–92.1%). The median diagnostic accuracy was 80.3% (IQR: 63.3–94.1%) with a median procedure accuracy of 84.2% (IQR: 68.7–88.7%). There was considerable variation in accuracy rates between studies (50.5–97.8%). Since the 2002 introduction of Payment by Results, accuracy has improved in some respects, for example primary diagnoses accuracy has improved from 73.8% (IQR: 59.3–92.1%) to 96.0% (IQR: 89.3–96.3), P= 0.020. Conclusion Accuracy rates are improving. Current levels of reported accuracy suggest that routinely collected data are sufficiently robust to support their use for research and managerial decision-making. PMID:21795302

  17. Error analysis for mesospheric temperature profiling by absorptive occultation sensors

    Directory of Open Access Journals (Sweden)

    M. J. Rieder

    Full Text Available An error analysis for mesospheric profiles retrieved from absorptive occultation data has been performed, starting with realistic error assumptions as would apply to intensity data collected by available high-precision UV photodiode sensors. Propagation of statistical errors was investigated through the complete retrieval chain from measured intensity profiles to atmospheric density, pressure, and temperature profiles. We assumed unbiased errors as the occultation method is essentially self-calibrating and straight-line propagation of occulted signals as we focus on heights of 50–100 km, where refractive bending of the sensed radiation is negligible. Throughout the analysis the errors were characterized at each retrieval step by their mean profile, their covariance matrix and their probability density function (pdf. This furnishes, compared to a variance-only estimation, a much improved insight into the error propagation mechanism. We applied the procedure to a baseline analysis of the performance of a recently proposed solar UV occultation sensor (SMAS – Sun Monitor and Atmospheric Sounder and provide, using a reasonable exponential atmospheric model as background, results on error standard deviations and error correlation functions of density, pressure, and temperature profiles. Two different sensor photodiode assumptions are discussed, respectively, diamond diodes (DD with 0.03% and silicon diodes (SD with 0.1% (unattenuated intensity measurement noise at 10 Hz sampling rate. A factor-of-2 margin was applied to these noise values in order to roughly account for unmodeled cross section uncertainties. Within the entire height domain (50–100 km we find temperature to be retrieved to better than 0.3 K (DD / 1 K (SD accuracy, respectively, at 2 km height resolution. The results indicate that absorptive occultations acquired by a SMAS-type sensor could provide mesospheric profiles of fundamental variables such as temperature with

  18. Error analysis for mesospheric temperature profiling by absorptive occultation sensors

    Directory of Open Access Journals (Sweden)

    M. J. Rieder

    2001-01-01

    Full Text Available An error analysis for mesospheric profiles retrieved from absorptive occultation data has been performed, starting with realistic error assumptions as would apply to intensity data collected by available high-precision UV photodiode sensors. Propagation of statistical errors was investigated through the complete retrieval chain from measured intensity profiles to atmospheric density, pressure, and temperature profiles. We assumed unbiased errors as the occultation method is essentially self-calibrating and straight-line propagation of occulted signals as we focus on heights of 50–100 km, where refractive bending of the sensed radiation is negligible. Throughout the analysis the errors were characterized at each retrieval step by their mean profile, their covariance matrix and their probability density function (pdf. This furnishes, compared to a variance-only estimation, a much improved insight into the error propagation mechanism. We applied the procedure to a baseline analysis of the performance of a recently proposed solar UV occultation sensor (SMAS – Sun Monitor and Atmospheric Sounder and provide, using a reasonable exponential atmospheric model as background, results on error standard deviations and error correlation functions of density, pressure, and temperature profiles. Two different sensor photodiode assumptions are discussed, respectively, diamond diodes (DD with 0.03% and silicon diodes (SD with 0.1% (unattenuated intensity measurement noise at 10 Hz sampling rate. A factor-of-2 margin was applied to these noise values in order to roughly account for unmodeled cross section uncertainties. Within the entire height domain (50–100 km we find temperature to be retrieved to better than 0.3 K (DD / 1 K (SD accuracy, respectively, at 2 km height resolution. The results indicate that absorptive occultations acquired by a SMAS-type sensor could provide mesospheric profiles of fundamental variables such as temperature with

  19. A procedure to analyze surface profiles of the protein molecules visualized by quick-freeze deep-etch replica electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kimori, Yoshitaka [Division of Biomolecular Imaging, Institute of Medical Science, The University of Tokyo, Minato-ku, Tokyo 108-8639 (Japan); Department of Bioscience and Bioinformatics, Kyushu Institute of Technology, Iizuka, Fukuoka 820-8502 (Japan); Oguchi, Yosuke [Department of Electric Engineering, Kogakuin University, Hachioji, Tokyo 192-0015 (Japan); Ichise, Norihiko [Department of Visual Communication, Komazawa Women' s University, Inagi, Tokyo 206-8511 (Japan); Baba, Norio [Department of Electric Engineering, Kogakuin University, Hachioji, Tokyo 192-0015 (Japan); Katayama, Eisaku [Division of Biomolecular Imaging, Institute of Medical Science, The University of Tokyo, Minato-ku, Tokyo 108-8639 (Japan)]. E-mail: ekatayam@ims.u-tokyo.ac.jp

    2007-01-15

    Quick-freeze deep-etch replica electron microscopy gives high contrast snapshots of individual protein molecules under physiological conditions in vitro or in situ. The images show delicate internal pattern, possibly reflecting the rotary-shadowed surface profile of the molecule. As a step to build the new system for the 'Structural analysis of single molecules', we propose a procedure to quantitatively characterize the structural property of individual molecules; e.g. conformational type and precise view-angle of the molecules, if the crystallographic structure of the target molecule is available. This paper presents a framework to determine the observed face of the protein molecule by analyzing the surface profile of individual molecules visualized in freeze-replica specimens. A comprehensive set of rotary-shadowed views of the protein molecule was artificially generated from the available atomic coordinates using light-rendering software. Exploiting new mathematical morphology-based image filter, characteristic features were extracted from each image and stored as template. Similar features were extracted from the true replica image and the most likely projection angle and the conformation of the observed particle were determined by quantitative comparison with a set of archived images. The performance and the robustness of the procedure were examined with myosin head structure in defined configuration for actual application.

  20. A procedure to analyze surface profiles of the protein molecules visualized by quick-freeze deep-etch replica electron microscopy

    International Nuclear Information System (INIS)

    Kimori, Yoshitaka; Oguchi, Yosuke; Ichise, Norihiko; Baba, Norio; Katayama, Eisaku

    2007-01-01

    Quick-freeze deep-etch replica electron microscopy gives high contrast snapshots of individual protein molecules under physiological conditions in vitro or in situ. The images show delicate internal pattern, possibly reflecting the rotary-shadowed surface profile of the molecule. As a step to build the new system for the 'Structural analysis of single molecules', we propose a procedure to quantitatively characterize the structural property of individual molecules; e.g. conformational type and precise view-angle of the molecules, if the crystallographic structure of the target molecule is available. This paper presents a framework to determine the observed face of the protein molecule by analyzing the surface profile of individual molecules visualized in freeze-replica specimens. A comprehensive set of rotary-shadowed views of the protein molecule was artificially generated from the available atomic coordinates using light-rendering software. Exploiting new mathematical morphology-based image filter, characteristic features were extracted from each image and stored as template. Similar features were extracted from the true replica image and the most likely projection angle and the conformation of the observed particle were determined by quantitative comparison with a set of archived images. The performance and the robustness of the procedure were examined with myosin head structure in defined configuration for actual application

  1. SU-E-T-118: Analysis of Variability and Stability Between Two Water Tank Phantoms Utilizing Water Tank Commissioning Procedures

    International Nuclear Information System (INIS)

    Roring, J; Saenz, D; Cruz, W; Papanikolaou, N; Stathakis, S

    2015-01-01

    Purpose: The commissioning criteria of water tank phantoms are essential for proper accuracy and reproducibility in a clinical setting. This study outlines the results of mechanical and dosimetric testing between PTW MP3-M water tank system and the Standard Imaging Doseview 3D water tank system. Methods: Measurements were taken of each axis of movement on the tank using 30 cm calipers at 1, 5, 10, 50, 100, and 200 mm for accuracy and reproducibility of tank movement. Dosimetric quantities such as percent depth dose and dose profiles were compared between tanks using a 6 MV beam from a Varian 23EX LINAC. Properties such as scanning speed effects, central axis depth dose agreement with static measurements, reproducibility of measurements, symmetry and flatness, and scan time between tanks were also investigated. Results: Results showed high geometric accuracy within 0.2 mm. Central axis PDD and in-field profiles agreed within 0.75% between the tanks. These outcomes test many possible discrepancies in dose measurements across the two tanks and form a basis for comparison on a broader range of tanks in the future. Conclusion: Both 3D water scanning phantoms possess a high degree of spatial accuracy, allowing for equivalence in measurements regardless of the phantom used. A commissioning procedure when changing water tanks or upon receipt of a new tank is nevertheless critical to ensure consistent operation before and after the arrival of new hardware

  2. Audit of accuracy of clinical coding in oral surgery.

    Science.gov (United States)

    Naran, S; Hudovsky, A; Antscherl, J; Howells, S; Nouraei, S A R

    2014-10-01

    We aimed to study the accuracy of clinical coding within oral surgery and to identify ways in which it can be improved. We undertook did a multidisciplinary audit of a sample of 646 day case patients who had had oral surgery procedures between 2011 and 2012. We compared the codes given with their case notes and amended any discrepancies. The accuracy of coding was assessed for primary and secondary diagnoses and procedures, and for health resource groupings (HRGs). The financial impact of coding Subjectivity, Variability and Error (SVE) was assessed by reference to national tariffs. The audit resulted in 122 (19%) changes to primary diagnoses. The codes for primary procedures changed in 224 (35%) cases; 310 (48%) morbidities and complications had been missed, and 266 (41%) secondary procedures had been missed or were incorrect. This led to at least one change of coding in 496 (77%) patients, and to the HRG changes in 348 (54%) patients. The financial impact of this was £114 in lost revenue per patient. There is a high incidence of coding errors in oral surgery because of the large number of day cases, a lack of awareness by clinicians of coding issues, and because clinical coders are not always familiar with the large number of highly specialised abbreviations used. Accuracy of coding can be improved through the use of a well-designed proforma, and standards can be maintained by the use of an ongoing data quality assurance programme. Copyright © 2014. Published by Elsevier Ltd.

  3. Comparison of transition-matrix sampling procedures

    DEFF Research Database (Denmark)

    Yevick, D.; Reimer, M.; Tromborg, Bjarne

    2009-01-01

    We compare the accuracy of the multicanonical procedure with that of transition-matrix models of static and dynamic communication system properties incorporating different acceptance rules. We find that for appropriate ranges of the underlying numerical parameters, algorithmically simple yet high...... accurate procedures can be employed in place of the standard multicanonical sampling algorithm....

  4. Robot-assisted procedures in pediatric neurosurgery.

    Science.gov (United States)

    De Benedictis, Alessandro; Trezza, Andrea; Carai, Andrea; Genovese, Elisabetta; Procaccini, Emidio; Messina, Raffaella; Randi, Franco; Cossu, Silvia; Esposito, Giacomo; Palma, Paolo; Amante, Paolina; Rizzi, Michele; Marras, Carlo Efisio

    2017-05-01

    OBJECTIVE During the last 3 decades, robotic technology has rapidly spread across several surgical fields due to the continuous evolution of its versatility, stability, dexterity, and haptic properties. Neurosurgery pioneered the development of robotics, with the aim of improving the quality of several procedures requiring a high degree of accuracy and safety. Moreover, robot-guided approaches are of special interest in pediatric patients, who often have altered anatomy and challenging relationships between the diseased and eloquent structures. Nevertheless, the use of robots has been rarely reported in children. In this work, the authors describe their experience using the ROSA device (Robotized Stereotactic Assistant) in the neurosurgical management of a pediatric population. METHODS Between 2011 and 2016, 116 children underwent ROSA-assisted procedures for a variety of diseases (epilepsy, brain tumors, intra- or extraventricular and tumor cysts, obstructive hydrocephalus, and movement and behavioral disorders). Each patient received accurate preoperative planning of optimal trajectories, intraoperative frameless registration, surgical treatment using specific instruments held by the robotic arm, and postoperative CT or MR imaging. RESULTS The authors performed 128 consecutive surgeries, including implantation of 386 electrodes for stereo-electroencephalography (36 procedures), neuroendoscopy (42 procedures), stereotactic biopsy (26 procedures), pallidotomy (12 procedures), shunt placement (6 procedures), deep brain stimulation procedures (3 procedures), and stereotactic cyst aspiration (3 procedures). For each procedure, the authors analyzed and discussed accuracy, timing, and complications. CONCLUSIONS To the best their knowledge, the authors present the largest reported series of pediatric neurosurgical cases assisted by robotic support. The ROSA system provided improved safety and feasibility of minimally invasive approaches, thus optimizing the surgical

  5. Accurate, fully-automated NMR spectral profiling for metabolomics.

    Directory of Open Access Journals (Sweden)

    Siamak Ravanbakhsh

    Full Text Available Many diseases cause significant changes to the concentrations of small molecules (a.k.a. metabolites that appear in a person's biofluids, which means such diseases can often be readily detected from a person's "metabolic profile"-i.e., the list of concentrations of those metabolites. This information can be extracted from a biofluids Nuclear Magnetic Resonance (NMR spectrum. However, due to its complexity, NMR spectral profiling has remained manual, resulting in slow, expensive and error-prone procedures that have hindered clinical and industrial adoption of metabolomics via NMR. This paper presents a system, BAYESIL, which can quickly, accurately, and autonomously produce a person's metabolic profile. Given a 1D 1H NMR spectrum of a complex biofluid (specifically serum or cerebrospinal fluid, BAYESIL can automatically determine the metabolic profile. This requires first performing several spectral processing steps, then matching the resulting spectrum against a reference compound library, which contains the "signatures" of each relevant metabolite. BAYESIL views spectral matching as an inference problem within a probabilistic graphical model that rapidly approximates the most probable metabolic profile. Our extensive studies on a diverse set of complex mixtures including real biological samples (serum and CSF, defined mixtures and realistic computer generated spectra; involving > 50 compounds, show that BAYESIL can autonomously find the concentration of NMR-detectable metabolites accurately (~ 90% correct identification and ~ 10% quantification error, in less than 5 minutes on a single CPU. These results demonstrate that BAYESIL is the first fully-automatic publicly-accessible system that provides quantitative NMR spectral profiling effectively-with an accuracy on these biofluids that meets or exceeds the performance of trained experts. We anticipate this tool will usher in high-throughput metabolomics and enable a wealth of new applications of

  6. Evaluating Behavioral Self-Monitoring with Accuracy Training for Changing Computer Work Postures

    Science.gov (United States)

    Gravina, Nicole E.; Loewy, Shannon; Rice, Anna; Austin, John

    2013-01-01

    The primary purpose of this study was to replicate and extend a study by Gravina, Austin, Schroedter, and Loewy (2008). A similar self-monitoring procedure, with the addition of self-monitoring accuracy training, was implemented to increase the percentage of observations in which participants worked in neutral postures. The accuracy training…

  7. Generic calibration procedures for nacelle-based profiling lidars

    DEFF Research Database (Denmark)

    Borraccino, Antoine; Courtney, Michael; Wagner, Rozenn

    In power performance testing, it has been demonstrated that the effects of wind speed and direction variations over the rotor disk can no longer be neglected for large wind turbines [1]. A new generation of commercial nacelle-based lidars is now available, offering wind profiling capabilities. De...

  8. Utility of CT-guided abdominal aspiration procedures

    International Nuclear Information System (INIS)

    Sundaram, M.; Wolverson, M.K.; Heiberg, E.; Pilla, T.; Vas, W.G.; Shields, J.B.

    1982-01-01

    Over 200 consecutive diagnostic needle aspiration procedures of the abdomen were performed under computed tomographic (CT) guidance. Biopsies were done of the liver in 88 patients, the pancreas in 28, the kidney in 20, and the retroperitoneum in 32; 30 underwent an aspiration procedure for characterization of an intraabdominal fluid collection. Accuracy of diagnosis was very high for hepatic (99%) and renal (100%) biopsies and in characterization of fluid collections (100%). Accuracy for retroperitoneal biopsy was 87.5% and for pancreatic biopsy 82%. Overall accuracy for all sites was 95%. There were one false-negative diagnosis for the liver and five false-negative diagnoses for the pancreas. Insufficient material was obtained for diagnosis in four instances of retroperitoneal biopsy. There were no false positives. The technique is facilitated by rapid CT scan time, large aperture gantry, and rapid CT image reconstruction. Twenty gauge needles were used more frequently than 22 gauge needles because of their greater rigidity and ease of control. CT-guided diagnostic aspiration procedures are particularly useful for diagnosis of small, deep-seated lesions and in evaluation of lesions found in severely ill patients. An experienced cytologist is essential to the success of the technique

  9. Accurate 3-D Profile Extraction of Skull Bone Using an Ultrasound Matrix Array.

    Science.gov (United States)

    Hajian, Mehdi; Gaspar, Robert; Maev, Roman Gr

    2017-12-01

    The present study investigates the feasibility, accuracy, and precision of 3-D profile extraction of the human skull bone using a custom-designed ultrasound matrix transducer in Pulse-Echo. Due to the attenuative scattering properties of the skull, the backscattered echoes from the inner surface of the skull are severely degraded, attenuated, and at some points overlapped. Furthermore, the speed of sound (SOS) in the skull varies significantly in different zones and also from case to case; if considered constant, it introduces significant error to the profile measurement. A new method for simultaneous estimation of the skull profiles and the sound speed value is presented. The proposed method is a two-folded procedure: first, the arrival times of the backscattered echoes from the skull bone are estimated using multi-lag phase delay (MLPD) and modified space alternating generalized expectation maximization (SAGE) algorithms. Next, these arrival times are fed into an adaptive sound speed estimation algorithm to compute the optimal SOS value and subsequently, the skull bone thickness. For quantitative evaluation, the estimated bone phantom thicknesses were compared with the mechanical measurements. The accuracies of the bone thickness measurements using MLPD and modified SAGE algorithms combined with the adaptive SOS estimation were 7.93% and 4.21%, respectively. These values were 14.44% and 10.75% for the autocorrelation and cross-correlation methods. Additionally, the Bland-Altman plots showed the modified SAGE outperformed the other methods with -0.35 and 0.44 mm limits of agreement. No systematic error that could be related to the skull bone thickness was observed for this method.

  10. Can the diagnostic accuracy of radionuclide ventriculography during exercise be improved by means of a step-up loading procedure?

    International Nuclear Information System (INIS)

    Ruegenberg, T.

    1985-01-01

    34 patients (31 of whom were coronary heart disease sufferers as proven by angiography) and further 3 patients failing to show symptoms of this disorder were subjected to radionuclide ventriculography carried out with the aid of 99m Tc-labelled erythrocytes in such a way that examinations at rest were directly followed by maximum loading tests. In a second series of examinations a step-up procedure was adopted where initial recordings at rest were followed by preliminary exercise tests using only 25% of the maximum load. The parameters chosen to evaluate the results were heart rate, ejection fraction, maximum velocity of changes in volume, endsystolic and enddiastolic volumes (ESV and EDV) as well as cardiac output. In 23 patients the preliminary exercise test revealed an insufficient increase or even decrease of the ejection fraction that was associated with delayed volume changes, increases in ESV and EDV as well as reductions in cardiac output and in 21 patients it became evident during those examinations that the onset of stenocardiac complaints was preceded by markedly pronounced function disorders in the left ventricle. It was concluded from these findings that the step-up procedure followed here may in some patients provide additional information on the level of myocardial performance. It can thus be assumed to contribute considerably to higher diagnostic accuracy, although it requires no more time than conventional exercise tests and is not associated with additional radiation exposure. (TRV) [de

  11. Determination of Solution Accuracy of Numerical Schemes as Part of Code and Calculation Verification

    Energy Technology Data Exchange (ETDEWEB)

    Blottner, F.G.; Lopez, A.R.

    1998-10-01

    This investigation is concerned with the accuracy of numerical schemes for solving partial differential equations used in science and engineering simulation codes. Richardson extrapolation methods for steady and unsteady problems with structured meshes are presented as part of the verification procedure to determine code and calculation accuracy. The local truncation error de- termination of a numerical difference scheme is shown to be a significant component of the veri- fication procedure as it determines the consistency of the numerical scheme, the order of the numerical scheme, and the restrictions on the mesh variation with a non-uniform mesh. Genera- tion of a series of co-located, refined meshes with the appropriate variation of mesh cell size is in- vestigated and is another important component of the verification procedure. The importance of mesh refinement studies is shown to be more significant than just a procedure to determine solu- tion accuracy. It is suggested that mesh refinement techniques can be developed to determine con- sistency of numerical schemes and to determine if governing equations are well posed. The present investigation provides further insight into the conditions and procedures required to effec- tively use Richardson extrapolation with mesh refinement studies to achieve confidence that sim- ulation codes are producing accurate numerical solutions.

  12. Transbronchial Lung Cryobiopsy and Video-assisted Thoracoscopic Lung Biopsy in the Diagnosis of Diffuse Parenchymal Lung Disease. A Meta-analysis of Diagnostic Test Accuracy.

    Science.gov (United States)

    Iftikhar, Imran H; Alghothani, Lana; Sardi, Alejandro; Berkowitz, David; Musani, Ali I

    2017-07-01

    Transbronchial lung cryobiopsy is increasingly being used for the assessment of diffuse parenchymal lung diseases. Several studies have shown larger biopsy samples and higher yields compared with conventional transbronchial biopsies. However, the higher risk of bleeding and other complications has raised concerns for widespread use of this modality. To study the diagnostic accuracy and safety profile of transbronchial lung cryobiopsy and compare with video-assisted thoracoscopic surgery (VATS) by reviewing available evidence from the literature. Medline and PubMed were searched from inception until December 2016. Data on diagnostic performance were abstracted by constructing two-by-two contingency tables for each study. Data on a priori selected safety outcomes were collected. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of transbronchial lung cryobiopsy were 83.7% (76.9-88.8%), 87% (85-89%), and 57% (40-73%), respectively. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of VATS were 92.7% (87.6-95.8%), 91.0% (89-92%), and 58% (31-81%), respectively. The incidence of grade 2 (moderate to severe) endobronchial bleeding after transbronchial lung cryobiopsy and of post-procedural pneumothorax was 4.9% (2.2-10.7%) and 9.5% (5.9-14.9%), respectively. Although the diagnostic test accuracy measures of transbronchial lung cryobiopsy lag behind those of VATS, with an acceptable safety profile and potential cost savings, the former could be considered as an alternative in the evaluation of patients with diffuse parenchymal lung diseases.

  13. Remifentanil maintains lower initial delayed nonmatching-to-sample accuracy compared to food pellets in male rhesus monkeys.

    Science.gov (United States)

    Hutsell, Blake A; Banks, Matthew L

    2017-12-01

    Emerging human laboratory and preclinical drug self-administration data suggest that a history of contingent abused drug exposure impairs performance in operant discrimination procedures, such as delayed nonmatching-to-sample (DNMTS), that are hypothesized to assess components of executive function. However, these preclinical discrimination studies have exclusively used food as the reinforcer and the effects of drugs as reinforcers in these operant procedures are unknown. The present study determined effects of contingent intravenous remifentanil injections on DNMTS performance hypothesized to assess 1 aspect of executive function, working memory. Daily behavioral sessions consisted of 2 components with sequential intravenous remifentanil (0, 0.01-1.0 μg/kg/injection) or food (0, 1-10 pellets) availability in nonopioid dependent male rhesus monkeys (n = 3). Remifentanil functioned as a reinforcer in the DNMTS procedure. Similar delay-dependent DNMTS accuracy was observed under both remifentanil- and food-maintained components, such that higher accuracies were maintained at shorter (0.1-1.0 s) delays and lower accuracies approaching chance performance were maintained at longer (10-32 s) delays. Remifentanil maintained significantly lower initial DNMTS accuracy compared to food. Reinforcer magnitude was not an important determinant of DNMTS accuracy for either remifentanil or food. These results extend the range of experimental procedures under which drugs function as reinforcers. Furthermore, the selective remifentanil-induced decrease in initial DNMTS accuracy is consistent with a selective impairment of attentional, but not memorial, processes. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. Comparative analysis of diagnostic accuracy of different brain biopsy procedures

    OpenAIRE

    Jain Deepali; Sharma Mehar; Sarkar Chitra; Gupta Deepak; Singh Manmohan; Mahapatra A

    2006-01-01

    Background: Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. Aims: The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different s...

  15. Global metabolic profiling procedures for urine using UPLC-MS.

    Science.gov (United States)

    Want, Elizabeth J; Wilson, Ian D; Gika, Helen; Theodoridis, Georgios; Plumb, Robert S; Shockcor, John; Holmes, Elaine; Nicholson, Jeremy K

    2010-06-01

    The production of 'global' metabolite profiles involves measuring low molecular-weight metabolites (sample preparation, stability/storage and the selection of chromatographic conditions that balance metabolome coverage, chromatographic resolution and throughput. We discuss quality control and metabolite identification, as well as provide details of multivariate data analysis approaches for analyzing such MS data. Using this protocol, the analysis of a sample set in 96-well plate format, would take ca. 30 h, including 1 h for system setup, 1-2 h for sample preparation, 24 h for UPLC-MS analysis and 1-2 h for initial data processing. The use of UPLC-MS for metabolic profiling in this way is not faster than the conventional HPLC-based methods but, because of improved chromatographic performance, provides superior metabolome coverage.

  16. A model to generate beam profiles of the Varian Clinac 4 for three-dimensional dose calculation: open fields

    International Nuclear Information System (INIS)

    Lam, K.S.; Lam, W.C.

    1984-01-01

    For the Clinac 4, open field profiles measured in the principal plane have higher intensity ''horns'' than those in off-axis planes. The maximum deviation occurs at 1-cm depth, where in the worst case of large field sizes and off-axis distances the deviation can be as high as 16% in the region near the horns. A model is proposed to generate open field beam profiles in off-axis planes, based on measured profiles in the transverse principal plane and in the largest field size diagonal plane of the machine. Within the central 90% portion of the field, the maximum deviation of the generated profiles from the measured ones at the same off-axis distance varies from about 3% at 1-cm depth to about 2% at 13-cm depth and then increases to less than 5% at 25-cm depth, even for very large field sizes and off-axis distances. Very little additional computer time and data storage are required for this procedure. Using these profiles, the Milan and Bentley method can be extended to three-dimensional treatment planning with good accuracy

  17. Accuracy criteria recommended for the certification of gravimetric coal-mine-dust samplers

    International Nuclear Information System (INIS)

    Bowman, J.D.; Bartley, D.L.; Breuer, G.M.; Doemeny, L.J.; Murdock, D.J.

    1984-07-01

    Procedures for testing bias and precision of gravimetric coal-mine-dust sampling units are reviewed. Performance criteria for NIOSH certification of personal coal-mine dust samplers are considered. The NIOSH criterion is an accuracy of 25% at the 95% confidence interval. Size distributions of coal-mine-dust are discussed. Methods for determining size distributions are described. Sampling and sizing methods are considered. Cyclone parameter estimation is discussed. Bias computations for general sampling units are noted. Recommended procedures for evaluating bias and precision of gravimetric coal mine dust personal samplers are given. The authors conclude that when cyclones are operated at lower rates, the NIOSH accuracy criteria can be met

  18. The use of Brainsuite iCT for frame-based stereotactic procedures

    DEFF Research Database (Denmark)

    Skjøth-Rasmussen, Jane; Jespersen, Bo; Brennum, Jannick

    2015-01-01

    BACKGROUND: Frame-based stereotactic procedures are the gold standard because of their superior stereotactic accuracy. The procedure used to be in multiple steps and was especially cumbersome and hazardous in intubated patients. A single-step procedure using intraoperative CT was created...

  19. Predictive Accuracy of Exercise Stress Testing the Healthy Adult.

    Science.gov (United States)

    Lamont, Linda S.

    1981-01-01

    Exercise stress testing provides information on the aerobic capacity, heart rate, and blood pressure responses to graded exercises of a healthy adult. The reliability of exercise tests as a diagnostic procedure is discussed in relation to sensitivity and specificity and predictive accuracy. (JN)

  20. Identification of circulating miRNA biomarkers based on global quantitative real-time PCR profiling

    Directory of Open Access Journals (Sweden)

    Kang Kang

    2012-02-01

    Full Text Available Abstract MicroRNAs (miRNAs are small noncoding RNAs (18-25 nucleotides that regulate gene expression at the post-transcriptional level. Recent studies have demonstrated the presence of miRNAs in the blood circulation. Deregulation of miRNAs in serum or plasma has been associated with many diseases including cancers and cardiovascular diseases, suggesting the possible use of miRNAs as diagnostic biomarkers. However, the detection of the small amount of miRNAs found in serum or plasma requires a method with high sensitivity and accuracy. Therefore, the current study describes polymerase chain reaction (PCR-based methods for measuring circulating miRNAs. Briefly, the procedure involves four major steps: (1 sample collection and preparation; (2 global miRNAs profiling using quantitative real-time PCR (qRT-PCR; (3 data normalization and analysis; and (4 selection and validation of miRNA biomarkers. In conclusion, qRT-PCR is a promising method for profiling of circulating miRNAs as biomarkers.

  1. Multiple marker abundance profiling

    DEFF Research Database (Denmark)

    Hooper, Cornelia M.; Stevens, Tim J.; Saukkonen, Anna

    2017-01-01

    proteins and the scoring accuracy of lower-abundance proteins in Arabidopsis. NPAS was combined with subcellular protein localization data, facilitating quantitative estimations of organelle abundance during routine experimental procedures. A suite of targeted proteomics markers for subcellular compartment...

  2. Individual differences in eyewitness identification accuracy between sequential and simultaneous line-ups: consequences for police practice and jury decisions

    Directory of Open Access Journals (Sweden)

    Dominic Willmott

    2016-10-01

    Full Text Available Background Although previous research has indicated that sequential line-up procedures result in fewer mistaken identifications, this was found to be at the expense of accurate identifications more typical within simultaneous procedures. Hence, there remains a lack of agreement about which procedure is superior, and the interaction such procedures have with eyewitness confidence. The interaction between witness demographics and identification accuracy also remains unclear. Participants and procedure The opportunistic sample, consisting of 60 people from the general population, was divided randomly into two experimental conditions: simultaneous (SIM and sequential (SEQ. Participants in the sequential procedure observed 12 photographs, one at a time, deciding if they believed the suspect to be the person shown in the current photograph and unable to return to a given picture once they decided the individual shown was not the suspect described. Participants in the simultaneous condition were shown all 12 photographs concurrently and asked to determine which, if any, of the photographs was the suspect described. Results No significant differences were found in identification accuracy between line-up procedures, but significant differences in confidence levels between the two line-up procedures were found. Additionally, analysis of demographic features showed previous line-up experience to be significantly associated with identification accuracy. Conclusions The present research provides new insight into the interaction of eyewitness confidence between line-up techniques, offering an alternative explanation of witness confidence as well as procedural fairness. Evidence of practice effects increasing the accuracy of identification provides beneficial future implications for police line-up procedures and safer jury decisions, often reliant on identification evidence.

  3. Ti(r) profiles from the JET neutron profile monitor for ohmic discharges

    Energy Technology Data Exchange (ETDEWEB)

    Esposito, B. (ENEA, Frascati (Italy). Centro Ricerche Energia); Marcus, F.B.; Conroy, S.; Jarvis, O.N.; Loughlin, M.J.; Sadler, G.; Belle, P. van (Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking); Adams, J.M.; Watkins, N. (AEA Industrial Technology, Harwell (United Kingdom))

    1991-01-01

    A study has been made of the neutron emissivity, using the JET neutron profile monitor, obtained for ohmically heated deuterium discharges. Both one-dimensional (1-D) best-fit inversion procedures and 2-D tomography have been used to deduce the radial profile of the neutron emission from the line-integral data. The profiles of ion temperature and ion thermal conductivity are then derived. The scaling of the ion thermal conductivity with plasma current is found to be opposite to that of neoclassical theory. (author) 4 refs., 5 figs.

  4. An Innovative Adaptive Pushover Procedure Based on Storey Shear

    International Nuclear Information System (INIS)

    Shakeri, Kazem; Shayanfar, Mohsen A.

    2008-01-01

    Since the conventional pushover analyses are unable to consider the effect of the higher modes and progressive variation in dynamic properties, recent years have witnessed the development of some advanced adaptive pushover methods. However in these methods, using the quadratic combination rules to combine the modal forces result in a positive value in load pattern at all storeys and the reversal sign of the modes is removed; consequently these methods do not have a major advantage over their non-adaptive counterparts. Herein an innovative adaptive pushover method based on storey shear is proposed which can take into account the reversal signs in higher modes. In each storey the applied load pattern is derived from the storey shear profile; consequently, the sign of the applied loads in consecutive steps could be changed. Accuracy of the proposed procedure is examined by applying it to a 20-storey steel building. It illustrates a good estimation of the peak response in inelastic phase

  5. Comparison of VFA titration procedures used for monitoring the biogas process.

    Science.gov (United States)

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of

  6. EnzDP: improved enzyme annotation for metabolic network reconstruction based on domain composition profiles.

    Science.gov (United States)

    Nguyen, Nam-Ninh; Srihari, Sriganesh; Leong, Hon Wai; Chong, Ket-Fah

    2015-10-01

    Determining the entire complement of enzymes and their enzymatic functions is a fundamental step for reconstructing the metabolic network of cells. High quality enzyme annotation helps in enhancing metabolic networks reconstructed from the genome, especially by reducing gaps and increasing the enzyme coverage. Currently, structure-based and network-based approaches can only cover a limited number of enzyme families, and the accuracy of homology-based approaches can be further improved. Bottom-up homology-based approach improves the coverage by rebuilding Hidden Markov Model (HMM) profiles for all known enzymes. However, its clustering procedure relies firmly on BLAST similarity score, ignoring protein domains/patterns, and is sensitive to changes in cut-off thresholds. Here, we use functional domain architecture to score the association between domain families and enzyme families (Domain-Enzyme Association Scoring, DEAS). The DEAS score is used to calculate the similarity between proteins, which is then used in clustering procedure, instead of using sequence similarity score. We improve the enzyme annotation protocol using a stringent classification procedure, and by choosing optimal threshold settings and checking for active sites. Our analysis shows that our stringent protocol EnzDP can cover up to 90% of enzyme families available in Swiss-Prot. It achieves a high accuracy of 94.5% based on five-fold cross-validation. EnzDP outperforms existing methods across several testing scenarios. Thus, EnzDP serves as a reliable automated tool for enzyme annotation and metabolic network reconstruction. Available at: www.comp.nus.edu.sg/~nguyennn/EnzDP .

  7. Machine learning improves the accuracy of myocardial perfusion scintigraphy results

    International Nuclear Information System (INIS)

    Groselj, C.; Kukar, M.

    2002-01-01

    Objective: Machine learning (ML) an artificial intelligence method has in last decade proved to be an useful tool in many fields of decision making, also in some fields of medicine. By reports, its decision accuracy usually exceeds the human one. Aim: To assess applicability of ML in interpretation of the stress myocardial perfusion scintigraphy results in coronary artery disease diagnostic process. Patients and methods: The 327 patient's data of planar stress myocardial perfusion scintigraphy were reevaluated in usual way. Comparing them with the results of coronary angiography the sensitivity, specificity and accuracy of the investigation were computed. The data were digitized and the decision procedure repeated by ML program 'Naive Bayesian classifier'. As the ML is able to simultaneously manipulate with whatever number of data, all reachable disease connected data (regarding history, habitus, risk factors, stress results) were added. The sensitivity, specificity and accuracy of scintigraphy were expressed in this way. The results of both decision procedures were compared. Conclusion: Using ML method, 19 more patients out of 327 (5.8%) were correctly diagnosed by stress myocardial perfusion scintigraphy. In this way ML could be an important tool for myocardial perfusion scintigraphy decision making

  8. Accurate procedure for deriving UTI at a submilliarcsecond accuracy from Greenwich Sidereal Time or from the stellar angle

    Science.gov (United States)

    Capitaine, N.; Gontier, A.-M.

    1993-08-01

    Present observations using modern astrometric techniques are supposed to provide the Earth orientation parameters, and therefore UT1, with an accuracy better than ±1 mas. In practice, UT1 is determined through the intermediary of Greenwich Sidereal Time (GST), using both the conventional relationship between Greenwich Mean Sidereal Time (GMST) and UTl (Aoki et al. 1982) and the so-called "equation of the equinoxes" limited to the first order terms with respect to the nutation quantities. This highly complex relation between sidereal time and UT1 is not accurate at the milliaresecond level which gives rise to spurious terms of milliaresecond amplitude in the derived UTl. A more complete relationship between GST and UT1 has been recommended by Aoki & Kinoshita (1983) and Aoki (1991) taking into account the second order terms in the difference between GST and GM ST, the largest one having an amplitude of 2.64 mas and a 18.6 yr-period. This paper explains how this complete expansion of GST implicitly uses the concept of "nonrotating origin" (NRO) as proposed by Guinot in 1979 and would, therefore, provide a more accurate value of UTl and consequently of the Earth's angular velocity. This paper shows, moreover, that such a procedure would be simplified and conceptually clarified by the explicit use of the NRO as previously proposed (Guinot 1979; Capitaine et al. 1986). The two corresponding options (implicit or explicit use of the NRO) are shown to be equivalent for defining the specific Earth's angle of rotation and then UT1. The of the use of such an accurate procedure which has been proposed in the new IERS standards (McCarthy 1992a) instead of the usual one are estimated for the practical derivation of UT1.

  9. Accuracy of Igenity genomically estimated breeding values for predicting Australian Angus BREEDPLAN traits.

    Science.gov (United States)

    Boerner, V; Johnston, D; Wu, X-L; Bauck, S

    2015-02-01

    Genomically estimated breeding values (GEBV) for Angus beef cattle are available from at least 2 commercial suppliers (Igenity [http://www.igenity.com] and Zoetis [http://www.zoetis.com]). The utility of these GEBV for improving genetic evaluation depends on their accuracies, which can be estimated by the genetic correlation with phenotypic target traits. Genomically estimated breeding values of 1,032 Angus bulls calculated from prediction equations (PE) derived by 2 different procedures in the U.S. Angus population were supplied by Igenity. Both procedures were based on Illuminia BovineSNP50 BeadChip genotypes. In procedure sg, GEBV were calculated from PE that used subsets of only 392 SNP, where these subsets were individually selected for each trait by BayesCπ. In procedure rg GEBV were calculated from PE derived in a ridge regression approach using all available SNP. Because the total set of 1,032 bulls with GEBV contained 732 individuals used in the Igenity training population, GEBV subsets were formed characterized by a decreasing average relationship between individuals in the subsets and individuals in the training population. Accuracies of GEBV were estimated as genetic correlations between GEBV and their phenotypic target traits modeling GEBV as trait observations in a bivariate REML approach, in which phenotypic observations were those recorded in the commercial Australian Angus seed stock sector. Using results from the GEBV subset excluding all training individuals as a reference, estimated accuracies were generally in agreement with those already published, with both types of GEBV (sg and rg) yielding similar results. Accuracies for growth traits ranged from 0.29 to 0.45, for reproductive traits from 0.11 to 0.53, and for carcass traits from 0.3 to 0.75. Accuracies generally decreased with an increasing genetic distance between the training and the validation population. However, for some carcass traits characterized by a low number of phenotypic

  10. Improving Accuracy for Image Fusion in Abdominal Ultrasonography

    Directory of Open Access Journals (Sweden)

    Caroline Ewertsen

    2012-08-01

    Full Text Available Image fusion involving real-time ultrasound (US is a technique where previously recorded computed tomography (CT or magnetic resonance images (MRI are reformatted in a projection to fit the real-time US images after an initial co-registration. The co-registration aligns the images by means of common planes or points. We evaluated the accuracy of the alignment when varying parameters as patient position, respiratory phase and distance from the co-registration points/planes. We performed a total of 80 co-registrations and obtained the highest accuracy when the respiratory phase for the co-registration procedure was the same as when the CT or MRI was obtained. Furthermore, choosing co-registration points/planes close to the area of interest also improved the accuracy. With all settings optimized a mean error of 3.2 mm was obtained. We conclude that image fusion involving real-time US is an accurate method for abdominal examinations and that the accuracy is influenced by various adjustable factors that should be kept in mind.

  11. Detection of the spatial accuracy of an O-arm in the region of surgical interest

    Science.gov (United States)

    Koivukangas, Tapani; Katisko, Jani P. A.; Koivukangsa, John P.

    2013-03-01

    Medical imaging is an essential component of a wide range of surgical procedures1. For image guided surgical (IGS) procedures, medical images are the main source of information2. The IGS procedures rely largely on obtained image data, so the data needs to provide differentiation between normal and abnormal tissues, especially when other surgical guidance devices are used in the procedures. The image data also needs to provide accurate spatial representation of the patient3. This research has concentrated on the concept of accuracy assessment of IGS devices to meet the needs of quality assurance in the hospital environment. For this purpose, two precision engineered accuracy assessment phantoms have been developed as advanced materials and methods for the community. The phantoms were designed to mimic the volume of a human head as the common region of surgical interest (ROSI). This paper introduces the utilization of the phantoms in spatial accuracy assessment of a commercial surgical 3D CT scanner, the O-Arm. The study presents methods and results of image quality detection of possible geometrical distortions in the region of surgical interest. The results show that in the pre-determined ROSI there are clear image distortion and artefacts using too high imaging parameters when scanning the objects. On the other hand, when using optimal parameters, the O-Arm causes minimal error in IGS accuracy. The detected spatial inaccuracy of the O-Arm with used parameters was in the range of less than 1.00 mm.

  12. Inactivation of the Medial-Prefrontal Cortex Impairs Interval Timing Precision, but Not Timing Accuracy or Scalar Timing in a Peak-Interval Procedure in Rats

    Directory of Open Access Journals (Sweden)

    Catalin V. Buhusi

    2018-06-01

    Full Text Available Motor sequence learning, planning and execution of goal-directed behaviors, and decision making rely on accurate time estimation and production of durations in the seconds-to-minutes range. The pathways involved in planning and execution of goal-directed behaviors include cortico-striato-thalamo-cortical circuitry modulated by dopaminergic inputs. A critical feature of interval timing is its scalar property, by which the precision of timing is proportional to the timed duration. We examined the role of medial prefrontal cortex (mPFC in timing by evaluating the effect of its reversible inactivation on timing accuracy, timing precision and scalar timing. Rats were trained to time two durations in a peak-interval (PI procedure. Reversible mPFC inactivation using GABA agonist muscimol resulted in decreased timing precision, with no effect on timing accuracy and scalar timing. These results are partly at odds with studies suggesting that ramping prefrontal activity is crucial to timing but closely match simulations with the Striatal Beat Frequency (SBF model proposing that timing is coded by the coincidental activation of striatal neurons by cortical inputs. Computer simulations indicate that in SBF, gradual inactivation of cortical inputs results in a gradual decrease in timing precision with preservation of timing accuracy and scalar timing. Further studies are needed to differentiate between timing models based on coincidence detection and timing models based on ramping mPFC activity, and clarify whether mPFC is specifically involved in timing, or more generally involved in attention, working memory, or response selection/inhibition.

  13. Error Estimation and Accuracy Improvements in Nodal Transport Methods

    International Nuclear Information System (INIS)

    Zamonsky, O.M.

    2000-01-01

    The accuracy of the solutions produced by the Discrete Ordinates neutron transport nodal methods is analyzed.The obtained new numerical methodologies increase the accuracy of the analyzed scheems and give a POSTERIORI error estimators. The accuracy improvement is obtained with new equations that make the numerical procedure free of truncation errors and proposing spatial reconstructions of the angular fluxes that are more accurate than those used until present. An a POSTERIORI error estimator is rigurously obtained for one dimensional systems that, in certain type of problems, allows to quantify the accuracy of the solutions. From comparisons with the one dimensional results, an a POSTERIORI error estimator is also obtained for multidimensional systems. LOCAL indicators, which quantify the spatial distribution of the errors, are obtained by the decomposition of the menctioned estimators. This makes the proposed methodology suitable to perform adaptive calculations. Some numerical examples are presented to validate the theoretical developements and to illustrate the ranges where the proposed approximations are valid

  14. Approaching nanometre accuracy in measurement of the profile deviation of a large plane mirror

    International Nuclear Information System (INIS)

    Müller, Andreas; Hofmann, Norbert; Manske, Eberhard

    2012-01-01

    The interferometric nanoprofilometer (INP), developed at the Institute of Process Measurement and Sensor Technology at the Ilmenau University of Technology, is a precision device for measuring the profile deviations of plane mirrors with a profile length of up to 250 mm at the nanometre scale. As its expanded uncertainty of U(l) = 7.8 nm at a confidence level of p = 95% (k = 2) was mainly influenced by the uncertainty of the straightness standard (3.6 nm) and the uncertainty caused by the signal and demodulation errors of the interferometer signals (1.2 nm), these two sources of uncertainty have been the subject of recent analyses and modifications. To measure the profile deviation of the standard mirror we performed a classic three-flat test using the INP. The three-flat test consists of a combination of measurements between three different test flats. The shape deviations of the three flats can then be determined by applying a least-squares solution of the resulting equation system. The results of this three-flat test showed surprisingly good consistency, enabling us to correct this systematic error in profile deviation measurements and reducing the uncertainty component of the standard mirror to 0.4 nm. Another area of research is the signal and demodulation error arising during the interpretation of the interferometer signals. In the case of the interferometric nanoprofilometer, the special challenge is that the maximum path length differences are too small during the scan of the entire profile deviation over perfectly aligned 250 mm long mirrors for proper interpolation and correction since they do not yet cover even half of an interference fringe. By applying a simple method of weighting to the interferometer data the common ellipse fitting could be performed successfully and the demodulation error was greatly reduced. The remaining uncertainty component is less than 0.5 nm. In summary we were successful in greatly reducing two major systematic errors. The

  15. ACCURACY ANALYSIS OF A LOW-COST PLATFORM FOR POSITIONING AND NAVIGATION

    Directory of Open Access Journals (Sweden)

    S. Hofmann

    2012-07-01

    Full Text Available This paper presents an accuracy analysis of a platform based on low-cost components for landmark-based navigation intended for research and teaching purposes. The proposed platform includes a LEGO MINDSTORMS NXT 2.0 kit, an Android-based Smartphone as well as a compact laser scanner Hokuyo URG-04LX. The robot is used in a small indoor environment, where GNSS is not available. Therefore, a landmark map was produced in advance, with the landmark positions provided to the robot. All steps of procedure to set up the platform are shown. The main focus of this paper is the reachable positioning accuracy, which was analyzed in this type of scenario depending on the accuracy of the reference landmarks and the directional and distance measuring accuracy of the laser scanner. Several experiments were carried out, demonstrating the practically achievable positioning accuracy. To evaluate the accuracy, ground truth was acquired using a total station. These results are compared to the theoretically achievable accuracies and the laser scanner’s characteristics.

  16. Automatic selection of reference taxa for protein-protein interaction prediction with phylogenetic profiling

    DEFF Research Database (Denmark)

    Simonsen, Martin; Maetschke, S.R.; Ragan, M.A.

    2012-01-01

    Motivation: Phylogenetic profiling methods can achieve good accuracy in predicting protein–protein interactions, especially in prokaryotes. Recent studies have shown that the choice of reference taxa (RT) is critical for accurate prediction, but with more than 2500 fully sequenced taxa publicly......: We present three novel methods for automating the selection of RT, using machine learning based on known protein–protein interaction networks. One of these methods in particular, Tree-Based Search, yields greatly improved prediction accuracies. We further show that different methods for constituting...... phylogenetic profiles often require very different RT sets to support high prediction accuracy....

  17. Quantifying and comparing dynamic predictive accuracy of joint models for longitudinal marker and time-to-event in presence of censoring and competing risks.

    Science.gov (United States)

    Blanche, Paul; Proust-Lima, Cécile; Loubère, Lucie; Berr, Claudine; Dartigues, Jean-François; Jacqmin-Gadda, Hélène

    2015-03-01

    Thanks to the growing interest in personalized medicine, joint modeling of longitudinal marker and time-to-event data has recently started to be used to derive dynamic individual risk predictions. Individual predictions are called dynamic because they are updated when information on the subject's health profile grows with time. We focus in this work on statistical methods for quantifying and comparing dynamic predictive accuracy of this kind of prognostic models, accounting for right censoring and possibly competing events. Dynamic area under the ROC curve (AUC) and Brier Score (BS) are used to quantify predictive accuracy. Nonparametric inverse probability of censoring weighting is used to estimate dynamic curves of AUC and BS as functions of the time at which predictions are made. Asymptotic results are established and both pointwise confidence intervals and simultaneous confidence bands are derived. Tests are also proposed to compare the dynamic prediction accuracy curves of two prognostic models. The finite sample behavior of the inference procedures is assessed via simulations. We apply the proposed methodology to compare various prediction models using repeated measures of two psychometric tests to predict dementia in the elderly, accounting for the competing risk of death. Models are estimated on the French Paquid cohort and predictive accuracies are evaluated and compared on the French Three-City cohort. © 2014, The International Biometric Society.

  18. A practical procedure to improve the accuracy of radiochromic film dosimetry. A integration with a correction method of uniformity correction and a red/blue correction method

    International Nuclear Information System (INIS)

    Uehara, Ryuzo; Tachibana, Hidenobu; Ito, Yasushi; Yoshino, Shinichi; Matsubayashi, Fumiyasu; Sato, Tomoharu

    2013-01-01

    It has been reported that the light scattering could worsen the accuracy of dose distribution measurement using a radiochromic film. The purpose of this study was to investigate the accuracy of two different films, EDR2 and EBT2, as film dosimetry tools. The effectiveness of a correction method for the non-uniformity caused from EBT2 film and the light scattering was also evaluated. In addition the efficacy of this correction method integrated with the red/blue correction method was assessed. EDR2 and EBT2 films were read using a flatbed charge-coupled device scanner (EPSON 10000 G). Dose differences on the axis perpendicular to the scanner lamp movement axis were within 1% with EDR2, but exceeded 3% (Maximum: +8%) with EBT2. The non-uniformity correction method, after a single film exposure, was applied to the readout of the films. A corrected dose distribution data was subsequently created. The correction method showed more than 10%-better pass ratios in dose difference evaluation than when the correction method was not applied. The red/blue correction method resulted in 5%-improvement compared with the standard procedure that employed red color only. The correction method with EBT2 proved to be able to rapidly correct non-uniformity, and has potential for routine clinical intensity modulated radiation therapy (IMRT) dose verification if the accuracy of EBT2 is required to be similar to that of EDR2. The use of red/blue correction method may improve the accuracy, but we recommend we should use the red/blue correction method carefully and understand the characteristics of EBT2 for red color only and the red/blue correction method. (author)

  19. [A practical procedure to improve the accuracy of radiochromic film dosimetry: a integration with a correction method of uniformity correction and a red/blue correction method].

    Science.gov (United States)

    Uehara, Ryuzo; Tachibana, Hidenobu; Ito, Yasushi; Yoshino, Shinichi; Matsubayashi, Fumiyasu; Sato, Tomoharu

    2013-06-01

    It has been reported that the light scattering could worsen the accuracy of dose distribution measurement using a radiochromic film. The purpose of this study was to investigate the accuracy of two different films, EDR2 and EBT2, as film dosimetry tools. The effectiveness of a correction method for the non-uniformity caused from EBT2 film and the light scattering was also evaluated. In addition the efficacy of this correction method integrated with the red/blue correction method was assessed. EDR2 and EBT2 films were read using a flatbed charge-coupled device scanner (EPSON 10000G). Dose differences on the axis perpendicular to the scanner lamp movement axis were within 1% with EDR2, but exceeded 3% (Maximum: +8%) with EBT2. The non-uniformity correction method, after a single film exposure, was applied to the readout of the films. A corrected dose distribution data was subsequently created. The correction method showed more than 10%-better pass ratios in dose difference evaluation than when the correction method was not applied. The red/blue correction method resulted in 5%-improvement compared with the standard procedure that employed red color only. The correction method with EBT2 proved to be able to rapidly correct non-uniformity, and has potential for routine clinical IMRT dose verification if the accuracy of EBT2 is required to be similar to that of EDR2. The use of red/blue correction method may improve the accuracy, but we recommend we should use the red/blue correction method carefully and understand the characteristics of EBT2 for red color only and the red/blue correction method.

  20. Accuracy of Visual Estimation of LASIK Flap Thickness.

    Science.gov (United States)

    Brenner, Jason E; Fadlallah, Ali; Hatch, Kathryn M; Choi, Catherine; Sayegh, Rony R; Kouyoumjian, Paul; Wu, Simon; Frangieh, George T; Melki, Samir A

    2017-11-01

    To assess the accuracy of surgeons' visual estimation of LASIK flap thickness when created by a femtosecond laser by comparing it to ultrasound measurements. Surgeons were asked to visually estimate the thickness of a femtosecond flap during the procedure. Total corneal thickness was measured by ultrasound pachymetry prior to the procedure and the stromal bed was similarly measured after flap lifting. The estimates from three experienced surgeons (cornea fellowship trained and more than 5 years in practice) were compared to those of three cornea fellows, with each surgeon evaluating 20 eyes (120 total). Surgeons were not told the thickness of the flaps unless required for safety reasons. The average difference between visual and ultrasonic estimation of LASIK flap thickness was 15.20 μm. The flap was 10 μm thicker than estimated in 37% of eyes, 20 μm thicker in 17% of eyes, and 30 μm thicker in 10% of eyes. The largest deviation was 53 μm. There was no statistically significant difference between the accuracy of experienced surgeons and fellows (P = .51). There are significant differences between surgeons' visual estimates and ultrasonic measurements of LASIK flap thickness. Relying on these visual estimates may lead to deeper excimer laser ablation than intended. This could lead to thinner residual stromal beds and higher percent tissue altered than planned. The authors recommend that surgeons measure flaps intraoperatively to maximize accuracy and safety. [J Refract Surg. 2017;33(11):765-767.]. Copyright 2017, SLACK Incorporated.

  1. Testing the accuracy of clustering redshifts with simulations

    Science.gov (United States)

    Scottez, V.; Benoit-Lévy, A.; Coupon, J.; Ilbert, O.; Mellier, Y.

    2018-03-01

    We explore the accuracy of clustering-based redshift inference within the MICE2 simulation. This method uses the spatial clustering of galaxies between a spectroscopic reference sample and an unknown sample. This study give an estimate of the reachable accuracy of this method. First, we discuss the requirements for the number objects in the two samples, confirming that this method does not require a representative spectroscopic sample for calibration. In the context of next generation of cosmological surveys, we estimated that the density of the Quasi Stellar Objects in BOSS allows us to reach 0.2 per cent accuracy in the mean redshift. Secondly, we estimate individual redshifts for galaxies in the densest regions of colour space ( ˜ 30 per cent of the galaxies) without using the photometric redshifts procedure. The advantage of this procedure is threefold. It allows: (i) the use of cluster-zs for any field in astronomy, (ii) the possibility to combine photo-zs and cluster-zs to get an improved redshift estimation, (iii) the use of cluster-z to define tomographic bins for weak lensing. Finally, we explore this last option and build five cluster-z selected tomographic bins from redshift 0.2 to 1. We found a bias on the mean redshift estimate of 0.002 per bin. We conclude that cluster-z could be used as a primary redshift estimator by next generation of cosmological surveys.

  2. Application of Real-Time 3D Navigation System in CT-Guided Percutaneous Interventional Procedures: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Priya Bhattacharji

    2017-01-01

    Full Text Available Introduction. To evaluate the accuracy of a quantitative 3D navigation system for CT-guided interventional procedures in a two-part study. Materials and Methods. Twenty-two procedures were performed in abdominal and thoracic phantoms. Accuracies of the 3D anatomy map registration and navigation were evaluated. Time used for the navigated procedures was recorded. In the IRB approved clinical evaluation, 21 patients scheduled for CT-guided thoracic and hepatic biopsy and ablations were recruited. CT-guided procedures were performed without following the 3D navigation display. Accuracy of navigation as well as workflow fitness of the system was evaluated. Results. In phantoms, the average 3D anatomy map registration error was 1.79 mm. The average navigated needle placement accuracy for one-pass and two-pass procedures, respectively, was 2.0±0.7 mm and 2.8±1.1 mm in the liver and 2.7±1.7 mm and 3.0±1.4 mm in the lung. The average accuracy of the 3D navigation system in human subjects was 4.6 mm ± 3.1 for all procedures. The system fits the existing workflow of CT-guided interventions with minimum impact. Conclusion. A 3D navigation system can be performed along the existing workflow and has the potential to navigate precision needle placement in CT-guided interventional procedures.

  3. Electron shower transverse profile measurement

    International Nuclear Information System (INIS)

    Lednev, A.A.

    1993-01-01

    A method to measure the shower transverse profile is described. Calibration data of the lead-glass spectrometer GAMS collected in a wide electron beam without any additional coordinate detector are used. The method may be used for the measurements in both cellular- and projective-type spectrometers. The results of measuring the 10 GeV electron shower profile in the GAMS spectrometer, without optical grease between the lead-glass radiators and photomultipliers, are approximated with an analytical function. The estimate of the coordinate accuracy is obtained. 5 refs., 8 figs

  4. A logical way through the limits of quantitation in inductively coupled plasma spectrochemistry

    International Nuclear Information System (INIS)

    Mermet, J.M.; Granier, G.; Fichet, P.

    2012-01-01

    The limit of quantitation (LOQ) is a crucial parameter in quantitative analysis. Besides the classical “10 s B approach”, other concepts have been previously described based on the limitation resulting from the calibration procedure, namely from the prediction bands and the uncertainty calibration. Because of the difficulty of obtaining a reliable value of the blank standard deviation, this approach was replaced by the study of the %RSD of the net signal as a function of the concentration. Recently described, the so-called accuracy profile method, accuracy being the contribution of both the trueness and the precision, allows the analyst to define a validity domain, the lowest point acting as a limit of quantitation. The aim of this work was to determine these various limits of quantitation, including that from the accuracy profile, to compare them, and to study the parameters that can influence their values. It was concluded that the LOQ deduced from the accuracy profile is a realistic one. Its value is mainly influenced by the calibration procedure, particularly when a weighting procedure is used. A 1/y weighting factor, y being the analyte line intensity, seems to be an efficient compromise for calibration. - Highlights: ► An analytical method is defined by its accuracy, i.e. both trueness and precision. ► A limit of quantitation should be based on an accuracy criterion and not on precision. ► The accuracy as a function of an analyte concentration is an accuracy profile. ► Profile-based tolerance intervals define a validity domain. ► The lowest concentration of this domain corresponds to a limit of quantitation.

  5. Accuracy of stereolithographic models of human anatomy

    International Nuclear Information System (INIS)

    Barker, T.M.; Earwaker, W.J.S.; Lisle, D.A.

    1994-01-01

    A study was undertaken to determine the dimensional accuracy of anatomical replicas derived from X-ray 3D computed tomography (CT) images and produced using the rapid prototyping technique of stereolithography (SLA). A dry bone skull and geometric phantom were scanned, and replicas were produced. Distance measurements were obtained to compare the original objects and the resulting replicas. Repeated measurements between anatomical landmarks were used for comparison of the original skull and replica. Results for the geometric phantom demonstrate a mean difference of +0.47mm, representing an accuracy of 97.7-99.12%. Measurements of the skull produced a range of absolute differences (maximum +4.62mm, minimum +0.1mm, mean +0.85mm). These results support the use of SLA models of human anatomical structures in such areas as pre-operative planning of complex surgical procedures. For applications where higher accuracy is required, improvements can be expected by utilizing smaller pixel resolution in the CT images. Stereolithographic models can now be confidently employed as accurate, three-dimensional replicas of complex, anatomical structures. 14 refs., 2 tabs., 8 figs

  6. Response moderation models for conditional dependence between response time and response accuracy.

    Science.gov (United States)

    Bolsinova, Maria; Tijmstra, Jesper; Molenaar, Dylan

    2017-05-01

    It is becoming more feasible and common to register response times in the application of psychometric tests. Researchers thus have the opportunity to jointly model response accuracy and response time, which provides users with more relevant information. The most common choice is to use the hierarchical model (van der Linden, 2007, Psychometrika, 72, 287), which assumes conditional independence between response time and accuracy, given a person's speed and ability. However, this assumption may be violated in practice if, for example, persons vary their speed or differ in their response strategies, leading to conditional dependence between response time and accuracy and confounding measurement. We propose six nested hierarchical models for response time and accuracy that allow for conditional dependence, and discuss their relationship to existing models. Unlike existing approaches, the proposed hierarchical models allow for various forms of conditional dependence in the model and allow the effect of continuous residual response time on response accuracy to be item-specific, person-specific, or both. Estimation procedures for the models are proposed, as well as two information criteria that can be used for model selection. Parameter recovery and usefulness of the information criteria are investigated using simulation, indicating that the procedure works well and is likely to select the appropriate model. Two empirical applications are discussed to illustrate the different types of conditional dependence that may occur in practice and how these can be captured using the proposed hierarchical models. © 2016 The British Psychological Society.

  7. Configural and component processing in simultaneous and sequential lineup procedures.

    Science.gov (United States)

    Flowe, Heather D; Smith, Harriet M J; Karoğlu, Nilda; Onwuegbusi, Tochukwu O; Rai, Lovedeep

    2016-01-01

    Configural processing supports accurate face recognition, yet it has never been examined within the context of criminal identification lineups. We tested, using the inversion paradigm, the role of configural processing in lineups. Recent research has found that face discrimination accuracy in lineups is better in a simultaneous compared to a sequential lineup procedure. Therefore, we compared configural processing in simultaneous and sequential lineups to examine whether there are differences. We had participants view a crime video, and then they attempted to identify the perpetrator from a simultaneous or sequential lineup. The test faces were presented either upright or inverted, as previous research has shown that inverting test faces disrupts configural processing. The size of the inversion effect for faces was the same across lineup procedures, indicating that configural processing underlies face recognition in both procedures. Discrimination accuracy was comparable across lineup procedures in both the upright and inversion condition. Theoretical implications of the results are discussed.

  8. An improved reference measurement procedure for triglycerides and total glycerides in human serum by isotope dilution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi

    2014-01-20

    Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation triglycerides and total glycerides.

  9. 23 CFR 650.313 - Inspection procedures.

    Science.gov (United States)

    2010-04-01

    ...) Quality control and quality assurance. Assure systematic quality control (QC) and quality assurance (QA) procedures are used to maintain a high degree of accuracy and consistency in the inspection program. Include... allow assessment of current bridge condition. Record the findings and results of bridge inspections on...

  10. Deconvolution of spectral line profile by FTS

    International Nuclear Information System (INIS)

    Lego, J.

    1977-01-01

    The possibility is studied of determining the components of the spectral line profile using Fourier transformation. The different types of the spectral line profiles are described and the conditions for their generation discussed. The main result is the discovery of the possibility to obtain the parameters of the different components directly from the interferogram without using the Fourier transformation. The method under discussion strongly simplifies evaluation while preserving or increasing accuracy. (author)

  11. Accuracy of Dolphin visual treatment objective (VTO prediction software on class III patients treated with maxillary advancement and mandibular setback

    Directory of Open Access Journals (Sweden)

    Robert J. Peterman

    2016-06-01

    Full Text Available Abstract Background Dolphin® visual treatment objective (VTO prediction software is routinely utilized by orthodontists during the treatment planning of orthognathic cases to help predict post-surgical soft tissue changes. Although surgical soft tissue prediction is considered to be a vital tool, its accuracy is not well understood in tow-jaw surgical procedures. The objective of this study was to quantify the accuracy of Dolphin Imaging’s VTO soft tissue prediction software on class III patients treated with maxillary advancement and mandibular setback and to validate the efficacy of the software in such complex cases. Methods This retrospective study analyzed the records of 14 patients treated with comprehensive orthodontics in conjunction with two-jaw orthognathic surgery. Pre- and post-treatment radiographs were traced and superimposed to determine the actual skeletal movements achieved in surgery. This information was then used to simulate surgery in the software and generate a final soft tissue patient profile prediction. Prediction images were then compared to the actual post-treatment profile photos to determine differences. Results Dolphin Imaging’s software was determined to be accurate within an error range of +/− 2 mm in the X-axis at most landmarks. The lower lip predictions were most inaccurate. Conclusions Clinically, the observed error suggests that the VTO may be used for demonstration and communication with a patient or consulting practitioner. However, Dolphin should not be useful for precise treatment planning of surgical movements. This program should be used with caution to prevent unrealistic patient expectations and dissatisfaction.

  12. Multiple position borehole extensometer procedure: Final draft

    International Nuclear Information System (INIS)

    1986-08-01

    The purpose of the Multiple Position Borehole Extensometer Procedure is to provide detailed information for MPBXs installed at the salt Deaf Smith County ESF. This procedure includes design of equipment, installation, instructions, instrument locations, measurement requirements, support requirements, quality assurance procedures, and data acquisition requirements. Data reduction procedures are also discussed; however, the relevance of the data is discussed elsewhere in the appropriate test plans. Sufficient detail is provided in this procedure to allow for integrating the requirements of this procedure into both the facility construction and overall underground testing programs; identifying necessary equipment for procurement; determining data acquisition requirements as input to Automatic Data Acquisition System (ADAS) design; providing step-by-step procedures for training personnel as well as for directing field operations; establishing quality assurance (QA) checkpoints and implementation methods; and defining data reduction methods and providing the anticipated accuracy of the system. 11 refs., 14 figs

  13. Measuring discharge with acoustic Doppler current profilers from a moving boat

    Science.gov (United States)

    Mueller, David S.; Wagner, Chad R.; Rehmel, Michael S.; Oberg, Kevin A.; Rainville, Francois

    2013-01-01

    The use of acoustic Doppler current profilers (ADCPs) from a moving boat is now a commonly used method for measuring streamflow. The technology and methods for making ADCP-based discharge measurements are different from the technology and methods used to make traditional discharge measurements with mechanical meters. Although the ADCP is a valuable tool for measuring streamflow, it is only accurate when used with appropriate techniques. This report presents guidance on the use of ADCPs for measuring streamflow; this guidance is based on the experience of U.S. Geological Survey employees and published reports, papers, and memorandums of the U.S. Geological Survey. The guidance is presented in a logical progression, from predeployment planning, to field data collection, and finally to post processing of the collected data. Acoustic Doppler technology and the instruments currently (2013) available also are discussed to highlight the advantages and limitations of the technology. More in-depth, technical explanations of how an ADCP measures streamflow and what to do when measuring in moving-bed conditions are presented in the appendixes. ADCP users need to know the proper procedures for measuring discharge from a moving boat and why those procedures are required, so that when the user encounters unusual field conditions, the procedures can be adapted without sacrificing the accuracy of the streamflow-measurement data.

  14. Test-Induced Priming Impairs Source Monitoring Accuracy in the DRM Procedure

    OpenAIRE

    Dewhurst, S.; Knott, L.; Howe, M. L.

    2011-01-01

    Three experiments investigated the effects of test-induced priming (TIP) on false recognition in the Deese/Roediger-McDermott procedure. In Experiment 1, TIP significantly increased false recognition for participants who made old/new decisions at test but not for participants who made remember/know judgements or were given diagnostic information to help them avoid false recognition. In Experiment 2, a TIP effect was observed with old/new recognition but not when participants were required to ...

  15. Evaluation of the generality and accuracy of a new mesh morphing procedure for the human femur.

    Science.gov (United States)

    Grassi, Lorenzo; Hraiech, Najah; Schileo, Enrico; Ansaloni, Mauro; Rochette, Michel; Viceconti, Marco

    2011-01-01

    Various papers described mesh morphing techniques for computational biomechanics, but none of them provided a quantitative assessment of generality, robustness, automation, and accuracy in predicting strains. This study aims to quantitatively evaluate the performance of a novel mesh-morphing algorithm. A mesh-morphing algorithm based on radial-basis functions and on manual selection of corresponding landmarks on template and target was developed. The periosteal geometries of 100 femurs were derived from a computed tomography scan database and used to test the algorithm generality in producing finite element (FE) morphed meshes. A published benchmark, consisting of eight femurs for which in vitro strain measurements and standard FE model strain prediction accuracy were available, was used to assess the accuracy of morphed FE models in predicting strains. Relevant parameters were identified to test the algorithm robustness to operative conditions. Time and effort needed were evaluated to define the algorithm degree of automation. Morphing was successful for 95% of the specimens, with mesh quality indicators comparable to those of standard FE meshes. Accuracy of the morphed meshes in predicting strains was good (R(2)>0.9, RMSE%0.05) and partially to the number of landmark used. Producing a morphed mesh starting from the triangularized geometry of the specimen requires on average 10 min. The proposed method is general, robust, automated, and accurate enough to be used in bone FE modelling from diagnostic data, and prospectively in applications such as statistical shape modelling. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Basis set approach in the constrained interpolation profile method

    International Nuclear Information System (INIS)

    Utsumi, T.; Koga, J.; Yabe, T.; Ogata, Y.; Matsunaga, E.; Aoki, T.; Sekine, M.

    2003-07-01

    We propose a simple polynomial basis-set that is easily extendable to any desired higher-order accuracy. This method is based on the Constrained Interpolation Profile (CIP) method and the profile is chosen so that the subgrid scale solution approaches the real solution by the constraints from the spatial derivative of the original equation. Thus the solution even on the subgrid scale becomes consistent with the master equation. By increasing the order of the polynomial, this solution quickly converges. 3rd and 5th order polynomials are tested on the one-dimensional Schroedinger equation and are proved to give solutions a few orders of magnitude higher in accuracy than conventional methods for lower-lying eigenstates. (author)

  17. Comparison of the effect of paper and computerized procedures on operator error rate and speed of performance

    International Nuclear Information System (INIS)

    Converse, S.A.; Perez, P.B.; Meyer, S.; Crabtree, W.

    1994-01-01

    The Computerized Procedures Manual (COPMA-II) is an advanced procedure manual that can be used to select and execute procedures, to monitor the state of plant parameters, and to help operators track their progress through plant procedures. COPMA-II was evaluated in a study that compared the speed and accuracy of operators' performance when they performed with COPMA-II and traditional paper procedures. Sixteen licensed reactor operators worked in teams of two to operate the Scales Pressurized Water Reactor Facility at North Carolina State University. Each team performed one change of power with each type of procedure to simulate performance under normal operating conditions. Teams then performed one accident scenario with COPMA-II and one with paper procedures. Error rates, performance times, and subjective estimates of workload were collected, and were evaluated for each combination of procedure type and scenario type. For the change of power task, accuracy and response time were not different for COPMA-II and paper procedures. Operators did initiate responses to both accident scenarios fastest with paper procedures. However, procedure type did not moderate response completion time for either accident scenario. For accuracy, performance with paper procedures resulted in twice as many errors as did performance with COPMA-II. Subjective measures of mental workload for the accident scenarios were not affected by procedure type

  18. MUSCLE: multiple sequence alignment with high accuracy and high throughput.

    Science.gov (United States)

    Edgar, Robert C

    2004-01-01

    We describe MUSCLE, a new computer program for creating multiple alignments of protein sequences. Elements of the algorithm include fast distance estimation using kmer counting, progressive alignment using a new profile function we call the log-expectation score, and refinement using tree-dependent restricted partitioning. The speed and accuracy of MUSCLE are compared with T-Coffee, MAFFT and CLUSTALW on four test sets of reference alignments: BAliBASE, SABmark, SMART and a new benchmark, PREFAB. MUSCLE achieves the highest, or joint highest, rank in accuracy on each of these sets. Without refinement, MUSCLE achieves average accuracy statistically indistinguishable from T-Coffee and MAFFT, and is the fastest of the tested methods for large numbers of sequences, aligning 5000 sequences of average length 350 in 7 min on a current desktop computer. The MUSCLE program, source code and PREFAB test data are freely available at http://www.drive5. com/muscle.

  19. Achieving Climate Change Absolute Accuracy in Orbit

    Science.gov (United States)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  20. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  1. Improving the accuracy of vehicle emissions profiles for urban transportation greenhouse gas and air pollution inventories.

    Science.gov (United States)

    Reyna, Janet L; Chester, Mikhail V; Ahn, Soyoung; Fraser, Andrew M

    2015-01-06

    Metropolitan greenhouse gas and air emissions inventories can better account for the variability in vehicle movement, fleet composition, and infrastructure that exists within and between regions, to develop more accurate information for environmental goals. With emerging access to high quality data, new methods are needed for informing transportation emissions assessment practitioners of the relevant vehicle and infrastructure characteristics that should be prioritized in modeling to improve the accuracy of inventories. The sensitivity of light and heavy-duty vehicle greenhouse gas (GHG) and conventional air pollutant (CAP) emissions to speed, weight, age, and roadway gradient are examined with second-by-second velocity profiles on freeway and arterial roads under free-flow and congestion scenarios. By creating upper and lower bounds for each factor, the potential variability which could exist in transportation emissions assessments is estimated. When comparing the effects of changes in these characteristics across U.S. cities against average characteristics of the U.S. fleet and infrastructure, significant variability in emissions is found to exist. GHGs from light-duty vehicles could vary by -2%-11% and CAP by -47%-228% when compared to the baseline. For heavy-duty vehicles, the variability is -21%-55% and -32%-174%, respectively. The results show that cities should more aggressively pursue the integration of emerging big data into regional transportation emissions modeling, and the integration of these data is likely to impact GHG and CAP inventories and how aggressively policies should be implemented to meet reductions. A web-tool is developed to aide cities in improving emissions uncertainty.

  2. Dimensional accuracy of aluminium extrusions in mechanical calibration

    Science.gov (United States)

    Raknes, Christian Arne; Welo, Torgeir; Paulsen, Frode

    2018-05-01

    Reducing dimensional variations in the extrusion process without increasing cost is challenging due to the nature of the process itself. An alternative approach—also from a cost perspective—is using extruded profiles with standard tolerances and utilize downstream processes, and thus calibrate the part within tolerance limits that are not achievable directly from the extrusion process. In this paper, two mechanical calibration strategies for the extruded product are investigated, utilizing the forming lines of the manufacturer. The first calibration strategy is based on global, longitudinal stretching in combination with local bending, while the second strategy utilizes the principle of transversal stretching and local bending of the cross-section. An extruded U-profile is used to make a comparison between the two methods using numerical analyses. To provide response surfaces with the FEA program, ABAQUS is used in combination with Design of Experiment (DOE). DOE is conducted with a two-level fractional factorial design to collect the appropriate data. The aim is to find the main factors affecting the dimension accuracy of the final part obtained by the two calibration methods. The results show that both calibration strategies have proven to reduce cross-sectional variations effectively form standard extrusion tolerances. It is concluded that mechanical calibration is a viable, low-cost alternative for aluminium parts that demand high dimensional accuracy, e.g. due to fit-up or welding requirements.

  3. Low-level profiling and MARTE-compatible modeling of software components for real-time systems

    NARCIS (Netherlands)

    Triantafyllidis, K.; Bondarev, E.; With, de P.H.N.

    2012-01-01

    In this paper, we present a method for (a) profiling of individual components at high accuracy level, (b) modeling of the components with the accurate data obtained from profiling, and (c) model conversion to the MARTE profile. The resulting performance models of individual components are used at

  4. Accuracy of Blood Loss Measurement during Cesarean Delivery

    OpenAIRE

    Doctorvaladan, Sahar V.; Jelks, Andrea T.; Hsieh, Eric W.; Thurer, Robert L.; Zakowski, Mark I.; Lagrew, David C.

    2017-01-01

    Objective?This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design?In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood...

  5. Impacts of land use/cover classification accuracy on regional climate simulations

    Science.gov (United States)

    Ge, Jianjun; Qi, Jiaguo; Lofgren, Brent M.; Moore, Nathan; Torbick, Nathan; Olson, Jennifer M.

    2007-03-01

    Land use/cover change has been recognized as a key component in global change. Various land cover data sets, including historically reconstructed, recently observed, and future projected, have been used in numerous climate modeling studies at regional to global scales. However, little attention has been paid to the effect of land cover classification accuracy on climate simulations, though accuracy assessment has become a routine procedure in land cover production community. In this study, we analyzed the behavior of simulated precipitation in the Regional Atmospheric Modeling System (RAMS) over a range of simulated classification accuracies over a 3 month period. This study found that land cover accuracy under 80% had a strong effect on precipitation especially when the land surface had a greater control of the atmosphere. This effect became stronger as the accuracy decreased. As shown in three follow-on experiments, the effect was further influenced by model parameterizations such as convection schemes and interior nudging, which can mitigate the strength of surface boundary forcings. In reality, land cover accuracy rarely obtains the commonly recommended 85% target. Its effect on climate simulations should therefore be considered, especially when historically reconstructed and future projected land covers are employed.

  6. Improving the accuracy of myocardial perfusion scintigraphy results by machine learning method

    International Nuclear Information System (INIS)

    Groselj, C.; Kukar, M.

    2002-01-01

    Full text: Machine learning (ML) as rapidly growing artificial intelligence subfield has already proven in last decade to be a useful tool in many fields of decision making, also in some fields of medicine. Its decision accuracy usually exceeds the human one. To assess applicability of ML in interpretation the results of stress myocardial perfusion scintigraphy for CAD diagnosis. The 327 patient's data of planar stress myocardial perfusion scintigraphy were reevaluated in usual way. Comparing them with the results of coronary angiography the sensitivity, specificity and accuracy for the investigation was computed. The data were digitized and the decision procedure repeated by ML program 'Naive Bayesian classifier'. As the ML is able to simultaneously manipulate of whatever number of data, all reachable disease connected data (regarding history, habitus, risk factors, stress results) were added. The sensitivity, specificity and accuracy for scintigraphy were expressed in this way. The results of both decision procedures were compared. With ML method 19 patients more out of 327 (5.8 %) were correctly diagnosed by stress myocardial perfusion scintigraphy. ML could be an important tool for decision making in myocardial perfusion scintigraphy. (author)

  7. Plasma profile recovery by function parameterisation

    International Nuclear Information System (INIS)

    McCarthy, P.J.; Sexton, M.C.

    1986-11-01

    The use of Function Parameterisation for the recovery of plasma profiles as a function of flux surface area from spatial point data directly combined with external magnetic measurements is demonstrated in the case of ASDEX electron temperature and density profiles. The extrapolated temperature on the magnetic axis is shown to be more reliable than that obtained from a conventional fitting procedure. (orig.)

  8. A New Profile Learning Model for Recommendation System based on Machine Learning Technique

    Directory of Open Access Journals (Sweden)

    Shereen H. Ali

    2016-03-01

    Full Text Available Recommender systems (RSs have been used to successfully address the information overload problem by providing personalized and targeted recommendations to the end users. RSs are software tools and techniques providing suggestions for items to be of use to a user, hence, they typically apply techniques and methodologies from Data Mining. The main contribution of this paper is to introduce a new user profile learning model to promote the recommendation accuracy of vertical recommendation systems. The proposed profile learning model employs the vertical classifier that has been used in multi classification module of the Intelligent Adaptive Vertical Recommendation (IAVR system to discover the user’s area of interest, and then build the user’s profile accordingly. Experimental results have proven the effectiveness of the proposed profile learning model, which accordingly will promote the recommendation accuracy.

  9. Improved accuracy in the estimation of blood velocity vectors using matched filtering

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Gori, P.

    2000-01-01

    the flow and the ultrasound beam (30, 45, 60, and 90 degrees). The parabolic flow has a peak velocity of 0.5 m/s and the pulse repetition frequency is 3.5 kHz. Simulating twenty emissions and calculating the cross-correlation using four pulse-echo lines for each estimate, the parabolic flow profile...... is found with a standard deviation of 0.014 m/s at 45 degrees (corresponding to an accuracy of 2.8%) and 0.022 m/s (corresponding to an accuracy of 4.4%) at 90 degrees, which is transverse to the ultrasound beam....

  10. Internal Control Organization Procedure

    OpenAIRE

    Radu Dorin Lenghel

    2013-01-01

    Internal control represents the totality of policies and procedures adopted by management, which contribute: to the fulfilment of managerial objectives, to the prevention and detection of frauds or errors, to the accuracy and exhaustiveness of accounting entries, as well as to the preparation in due course of financial accounting information. Internal control represents a managerial instrument which assures the fulfilment of objectives of the entity, being an ongoing process in which administ...

  11. Improvement and Validation of Weld Residual Stress Modelling Procedure

    International Nuclear Information System (INIS)

    Zang, Weilin; Gunnars, Jens; Dong, Pingsha; Hong, Jeong K.

    2009-06-01

    The objective of this work is to identify and evaluate improvements for the residual stress modelling procedure currently used in Sweden. There is a growing demand to eliminate any unnecessary conservatism involved in residual stress assumptions. The study was focused on the development and validation of an improved weld residual stress modelling procedure, by taking advantage of the recent advances in residual stress modelling and stress measurement techniques. The major changes applied in the new weld residual stress modelling procedure are: - Improved procedure for heat source calibration based on use of analytical solutions. - Use of an isotropic hardening model where mixed hardening data is not available. - Use of an annealing model for improved simulation of strain relaxation in re-heated material. The new modelling procedure is demonstrated to capture the main characteristics of the through thickness stress distributions by validation to experimental measurements. Three austenitic stainless steel butt-welds cases are analysed, covering a large range of pipe geometries. From the cases it is evident that there can be large differences between the residual stresses predicted using the new procedure, and the earlier procedure or handbook recommendations. Previously recommended profiles could give misleading fracture assessment results. The stress profiles according to the new procedure agree well with the measured data. If data is available then a mixed hardening model should be used

  12. Improvement and Validation of Weld Residual Stress Modelling Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Zang, Weilin; Gunnars, Jens (Inspecta Technology AB, Stockholm (Sweden)); Dong, Pingsha; Hong, Jeong K. (Center for Welded Structures Research, Battelle, Columbus, OH (United States))

    2009-06-15

    The objective of this work is to identify and evaluate improvements for the residual stress modelling procedure currently used in Sweden. There is a growing demand to eliminate any unnecessary conservatism involved in residual stress assumptions. The study was focused on the development and validation of an improved weld residual stress modelling procedure, by taking advantage of the recent advances in residual stress modelling and stress measurement techniques. The major changes applied in the new weld residual stress modelling procedure are: - Improved procedure for heat source calibration based on use of analytical solutions. - Use of an isotropic hardening model where mixed hardening data is not available. - Use of an annealing model for improved simulation of strain relaxation in re-heated material. The new modelling procedure is demonstrated to capture the main characteristics of the through thickness stress distributions by validation to experimental measurements. Three austenitic stainless steel butt-welds cases are analysed, covering a large range of pipe geometries. From the cases it is evident that there can be large differences between the residual stresses predicted using the new procedure, and the earlier procedure or handbook recommendations. Previously recommended profiles could give misleading fracture assessment results. The stress profiles according to the new procedure agree well with the measured data. If data is available then a mixed hardening model should be used

  13. Accuracy of spectral and finite difference schemes in 2D advection problems

    DEFF Research Database (Denmark)

    Naulin, V.; Nielsen, A.H.

    2003-01-01

    In this paper we investigate the accuracy of two numerical procedures commonly used to solve 2D advection problems: spectral and finite difference (FD) schemes. These schemes are widely used, simulating, e.g., neutral and plasma flows. FD schemes have long been considered fast, relatively easy...... that the accuracy of FD schemes can be significantly improved if one is careful in choosing an appropriate FD scheme that reflects conservation properties of the nonlinear terms and in setting up the grid in accordance with the problem....

  14. The Sample Size Influence in the Accuracy of the Image Classification of the Remote Sensing

    Directory of Open Access Journals (Sweden)

    Thomaz C. e C. da Costa

    2004-12-01

    Full Text Available Landuse/landcover maps produced by classification of remote sensing images incorporate uncertainty. This uncertainty is measured by accuracy indices using reference samples. The size of the reference sample is defined by approximation by a binomial function without the use of a pilot sample. This way the accuracy are not estimated, but fixed a priori. In case of divergency between the estimated and a priori accuracy the error of the sampling will deviate from the expected error. The size using pilot sample (theorically correct procedure justify when haven´t estimate of accuracy for work area, referent the product remote sensing utility.

  15. Study on assembly techniques and procedures for ITER tokamak device

    International Nuclear Information System (INIS)

    Obara, Kenjiro; Kakudate, Satoshi; Shibanuma, Kiyoshi; Sago, Hiromi; Ue, Koichi; Shimizu, Katsusuke; Onozuka, Masanori

    2006-06-01

    The International Thermonuclear Experimental Reactor (ITER) tokamak is mainly composed of a doughnut-shaped vacuum vessel (VV), four types of superconducting coils such as toroidal field coils (TF coils) arranged around the VV, and in-vessel components, such as blanket and divertor. The dimensions and weight of the respective components are around a few ten-meters and several hundred-tons. In addition, the whole tokamak assembly, which are composed of these components, are roughly estimated, 26 m in diameter, 18 m in height and over 16,500 tons in total weight. On the other hand, as for positioning and assembly tolerances of the VV and the TF coil are required to be a high accuracy of ±3 mm in spite of large size and heavy weight. The assembly procedures and techniques of the ITER tokamak are therefore studied, taking account of the tolerance requirements as well as the configuration of the tokamak with large size and heavy weight. Based on the above backgrounds, the assembly procedures and techniques, which are able to assemble the tokamak with high accuracy, are described in the present report. The tokamak assembly operations are categorized into six work break down structures (WBS), i.e., (1) preparation for assembly operations, (2) sub-assembly of the 40deg sector composed of 40deg VV sector, two TF coils and thermal shield between VV and TF coil at the assembly hall, (3) completion of the doughnut-shaped tokamak assembly composed of nine 40deg sectors in the cryostat at the tokamak pit, (4) measurement of positioning and accuracy after the completion of the tokamak assembly, (5) installation of the ex-vessel components, and (6) installation of in-vessel components. In the present report, two assembly operations of (2) and (3) in the above six WBS, which are the most critical in the tokamak assembly, are mainly described. The report describes the following newly developed tokamak assembly procedures and techniques, jigs and tools for assembly and metrology

  16. Variation in practice: an analysis of Scottish Surgical Profiles ENT data.

    Science.gov (United States)

    Yeo, J C L; Ah-See, K W; Mackenzie, K

    2013-02-01

    Variation in otolaryngology intervention rates is reported in the Scottish Surgical Profiles Project. Tonsillectomy is one of the selected key indicator procedures. The variation in practice was discussed nationally at the Scottish Otolaryngology Society summer meetings in 2009 and 2010. NHS Grampian had a significantly higher tonsillectomy rate compared with other Scottish NHS boards. To determine the accuracy of NHS Grampian data reported by the Information Service Division (ISD) and to record the appropriateness of listing of patients for tonsillectomy with reference to the Scottish Intercollegiate Guidelines Network (SIGN). Retrospective review of case notes and surgical records of patients who had undergone tonsillectomy between March 2007 and March 2008 in NHS Grampian. Between March 2007 and March 2008, 509 tonsillectomy cases were performed in NHS Grampian. This corresponded to the data received from ISD. 87% of tonsillectomies performed were compliant with SIGN guidelines. The Scottish otolaryngology clinicians have found the reporting of the intervention rates stimulating and challenging. Discussion of the surgical profile project regularly at national specialty meetings resulted in a preliminary detailed targeted audit of those who were persistent outliers for tonsillectomy. This refuted the presumed reasons for this variation, namely inaccurate figures from ISD and inappropriate listings by clinicians.

  17. Verification of the Time Accuracy of a Magnometer by Using a GPS Pulse Generator

    Directory of Open Access Journals (Sweden)

    Yasuhiro Minamoto

    2011-05-01

    Full Text Available The time accuracy of geomagnetic data is an important specification for one-second data distributions. We tested a procedure to verify the time accuracy of a fluxgate magnetometer by using a GPS pulse generator. The magnetometer was equipped with a high time resolution (100 Hz output, so the data delay could be checked directly. The delay detected from one-second data by a statistical method was larger than those from 0.1-s- and 0.01-s-resolution data. The test of the time accuracy revealed the larger delay and was useful for verifying the quality of the data.

  18. Complications of aesthetic medicine procedures: five case studies.

    Science.gov (United States)

    Smędra, A; Szustowski, S; Klemm, J; Jurczyk, A; Zalewska-Janowska, A; Berent, J

    2015-01-01

    The paper presents the cases of five patients who developed complications after aesthetic medicine procedures. Four of the cases involved women who reported to the Department of Forensic Medicine, Medical University of Lodz, for a description and legal qualification of bodily injuries suffered as a result of aesthetic medicine procedures, whereas one was related to the assessment of accuracy of medical management at the request of the prosecutor handling the case. The reported cases concerned acid exfoliation treatments, photoepilation and cryotherapy. The authors attempt to discuss the most common complications that may occur after aesthetic medicine procedures, and measures to avoid them.

  19. Photon caliper to achieve submillimeter positioning accuracy

    Science.gov (United States)

    Gallagher, Kyle J.; Wong, Jennifer; Zhang, Junan

    2017-09-01

    The purpose of this study was to demonstrate the feasibility of using a commercial two-dimensional (2D) detector array with an inherent detector spacing of 5 mm to achieve submillimeter accuracy in localizing the radiation isocenter. This was accomplished by delivering the Vernier ‘dose’ caliper to a 2D detector array where the nominal scale was the 2D detector array and the non-nominal Vernier scale was the radiation dose strips produced by the high-definition (HD) multileaf collimators (MLCs) of the linear accelerator. Because the HD MLC sequence was similar to the picket fence test, we called this procedure the Vernier picket fence (VPF) test. We confirmed the accuracy of the VPF test by offsetting the HD MLC bank by known increments and comparing the known offset with the VPF test result. The VPF test was able to determine the known offset within 0.02 mm. We also cross-validated the accuracy of the VPF test in an evaluation of couch hysteresis. This was done by using both the VPF test and the ExacTrac optical tracking system to evaluate the couch position. We showed that the VPF test was in agreement with the ExacTrac optical tracking system within a root-mean-square value of 0.07 mm for both the lateral and longitudinal directions. In conclusion, we demonstrated the VPF test can determine the offset between a 2D detector array and the radiation isocenter with submillimeter accuracy. Until now, no method to locate the radiation isocenter using a 2D detector array has been able to achieve such accuracy.

  20. Measurement of whole tire profile

    Science.gov (United States)

    Yang, Yongyue; Jiao, Wenguang

    2010-08-01

    In this paper, a precision measuring device is developed for obtaining characteristic curve of tire profile and its geometric parameters. It consists of a laser displacement measurement unit, a closed-loop precision two-dimensional coordinate table, a step motor control system and a fast data acquisition and analysis system. Based on the laser trigonometry, a data map of tire profile and coordinate values of all points can be obtained through corresponding data transformation. This device has a compact structure, a convenient control, a simple hardware circuit design and a high measurement precision. Experimental results indicate that measurement precision can meet the customer accuracy requirement of +/-0.02 mm.

  1. Characterization of the titanium Kβ spectral profile

    International Nuclear Information System (INIS)

    Chantler, C T; Smale, L F; Kinnane, M N; Illig, A J; Kimpton, J A; Crosby, D N

    2013-01-01

    Transition metals have Kα and Kβ characteristic radiation possessing complex asymmetric spectral profiles. Instrumental broadening normally encountered in x-ray experiments shifts features of profiles used for calibration, such as peak energy, by many times the quoted accuracies. We measure and characterize the titanium Kβ spectral profile. The peak energy of the titanium Kβ spectral profile is found to be 4931.966 ± 0.022 eV prior to instrumental broadening. This 4.5 ppm result decreases the uncertainty over the past literature by a factor of 2.6 and is 2.4 standard deviations from the previous standard. The spectrum is analysed and the resolution-free lineshape is extracted and listed for use in other experiments. We also incorporate improvement in analysis applied to earlier results for V Kβ. (paper)

  2. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    International Nuclear Information System (INIS)

    Koethe, Yilun; Xu, Sheng; Velusamy, Gnanasekar; Wood, Bradford J.; Venkatesan, Aradhana M.

    2014-01-01

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  3. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Koethe, Yilun [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Duke University School of Medicine, Durham, NC (United States); Xu, Sheng [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); Velusamy, Gnanasekar [Perfint Healthcare Pvt. Ltd., Chennai (India); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Venkatesan, Aradhana M. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States)

    2014-03-15

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  4. Quality assurance procedure for assessing mechanical accuracy of a radiation field center in stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Tatsumi, Daisaku; Ienaga, Akinori; Nakada, Ryosei; Yomoda, Akane; Inoue, Makoto; Ichida, Takao; Hosono, Masako

    2012-01-01

    Stereotactic radiotherapy requires a quality assurance (QA) program that ensures the mechanical accuracy of a radiation field center. We have proposed a QA method for achieving the above requirement by conducting the Winston Lutz test using an electronic portal image device (EPID). An action limit was defined as three times the standard deviation. Then, the action limits for mean deviations of the radiation field center during collimator rotation, gantry rotation, and couch rotation in clockwise and counterclockwise resulted in 0.11 mm, 0.52 mm, 0.37 mm, and 0.41 mm respectively. Two years after the QA program was launched, the mean deviation of the radiation field center during gantry rotation exceeded the above action limit. Consequently, a mechanical adjustment for the gantry was performed, thereby restoring the accuracy of the radiation field center. A field center shift of 0.5 mm was also observed after a micro multi-leaf collimator was unmounted. (author)

  5. Classification of Ultra-High Resolution Orthophotos Combined with DSM Using a Dual Morphological Top Hat Profile

    Directory of Open Access Journals (Sweden)

    Qian Zhang

    2015-12-01

    Full Text Available New aerial sensors and platforms (e.g., unmanned aerial vehicles (UAVs are capable of providing ultra-high resolution remote sensing data (less than a 30-cm ground sampling distance (GSD. This type of data is an important source for interpreting sub-building level objects; however, it has not yet been explored. The large-scale differences of urban objects, the high spectral variability and the large perspective effect bring difficulties to the design of descriptive features. Therefore, features representing the spatial information of the objects are essential for dealing with the spectral ambiguity. In this paper, we proposed a dual morphology top-hat profile (DMTHP using both morphology reconstruction and erosion with different granularities. Due to the high dimensional feature space, we have proposed an adaptive scale selection procedure to reduce the feature dimension according to the training samples. The DMTHP is extracted from both images and Digital Surface Models (DSM to obtain complimentary information. The random forest classifier is used to classify the features hierarchically. Quantitative experimental results on aerial images with 9-cm and UAV images with 5-cm GSD are performed. Under our experiments, improvements of 10% and 2% in overall accuracy are obtained in comparison with the well-known differential morphological profile (DMP feature, and superior performance is observed over other tested features. Large format data with 20,000 × 20,000 pixels are used to perform a qualitative experiment using the proposed method, which shows its promising potential. The experiments also demonstrate that the DSM information has greatly enhanced the classification accuracy. In the best case in our experiment, it gives rise to a classification accuracy from 63.93% (spectral information only to 94.48% (the proposed method.

  6. PEMBUATAN MODEL PROFIL MAHASISWA FAKULTAS TEKNIK UNIVERSITAS PANCASILA

    Directory of Open Access Journals (Sweden)

    Paryudi Paryudi

    2009-01-01

    Full Text Available Promotion is a must for a university to get students. With the innocence of the promotion team about the existing student profile, it will cause the team does not know which segment should be the promotion target. The consequence is that the promotion cost will be higher. In order to have a better promotion, we can use direct marketing method. In this method, a profile model of the existing students must be first created. With this profile model, promotion team can focus the promotion only to candidate student match with the model. The advantages of this method are: promotion cost can be reduced, response rate increase, and profit also increase. In order to create a model in direct marketing, we need previous promotion data. Since previous promotion data is not available, two methods in creating preliminary models are proposed. Next, the preliminary models will be tested using data mining software available in the market. Model with minimal accuracy of 75% will be chosen. If there are more than one model with minimal accuracy of 75%, then model with the highest accuracy will be chosen. Abstract in Bahasa Indonesia: Promosi merupakan suatu keharusan bagi sebuah universitas untuk mendapatkan mahasiswa. Dengan masih awamnya tim promosi terhadap profil mahasiswa yang sudah ada, maka tim promosi melakukan promosi tanpa melihat segmen pasar yang harus dituju. Konsekuensinya adalah biaya promosi menjadi lebih mahal. Untuk melakukan promosi dengan lebih baik, dapat menggunakan metode direct marketing. Pada metode ini, model profil dari mahasiswa yang sudah ada harus dibuat terlebih dulu. Dengan menggunakan model profil ini, tim promosi dapat memfokuskan promosi hanya pada calon-calon mahasiswa yang sesuai dengan model. Keuntungan dari metode promosi ini adalah biaya promosi dapat dikurangi, tingkat respon meningkat, dan keuntungan juga meningkat. Untuk membuat model pada direct marketing dibutuhkan data dari promosi sebelumnya. Karena data promosi

  7. Increase in the Accuracy of Calculating Length of Horizontal Cable SCS in Civil Engineering

    Science.gov (United States)

    Semenov, A.

    2017-11-01

    A modification of the method for calculating the horizontal cable consumption of SCS established at civil engineering facilities is proposed. The proposed procedure preserves the prototype simplicity and provides a 5 percent accuracy increase. The values of the achieved accuracy are justified, their compliance with the practice of real projects is proved. The method is brought to the level of the engineering algorithm and formalized in the form of 12/70 rule.

  8. Carpentry and Finishing Procedures. Building Maintenance. Module II. Instructor's Guide.

    Science.gov (United States)

    Hawk, Sam; Brunk, Art

    This curriculum guide, keyed to the building maintenance competency profile developed by industry and education professionals, provides three units on carpentry and finishing procedures. The first unit, Exterior Carpentry, contains the following lessons: carpentry safety procedures, ladder and scaffolding safety, door installation/repair,…

  9. Geographic profiling survey : a preliminary examination of geographic profilers' views and experiences

    NARCIS (Netherlands)

    Emeno, Karla; Bennell, Craig; Snook, Brent; Taylor, Paul Jonathon

    Geographic profiling (GP) is an investigative technique that involves predicting a serial offender?s home location (or some other anchor point) based on where he or she committed a crime. Although the use of GP in police investigations appears to be on the rise, little is known about the procedure

  10. Multi-Accuracy-Level Burning Plasma Simulations

    International Nuclear Information System (INIS)

    Artaud, J. F.; Basiuk, V.; Garcia, J.; Giruzzi, G.; Huynh, P.; Huysmans, G.; Imbeaux, F.; Johner, J.; Scheider, M.

    2007-01-01

    The design of a reactor grade tokamak is based on a hierarchy of tools. We present here three codes that are presently used for the simulations of burning plasmas. At the first level there is a 0-dimensional code that allows to choose a reasonable range of global parameters; in our case the HELIOS code was used for this task. For the second level we have developed a mixed 0-D / 1-D code called METIS that allows to study the main properties of a burning plasma, including profiles and all heat and current sources, but always under the constraint of energy and other empirical scaling laws. METIS is a fast code that permits to perform a large number of runs (a run takes about one minute) and design the main features of a scenario, or validate the results of the 0-D code on a full time evolution. At the top level, we used the full 1D1/2 suite of codes CRONOS that gives access to a detailed study of the plasma profiles evolution. CRONOS can use a variety of modules for source terms and transport coefficients computation with different level of complexity and accuracy: from simple estimators to highly sophisticated physics calculations. Thus it is possible to vary the accuracy of burning plasma simulations, as a trade-off with computation time. A wide range of scenario studies can thus be made with CRONOS and then validated with post-processing tools like MHD stability analysis. We will present in this paper results of this multi-level analysis applied to the ITER hybrid scenario. This specific example will illustrate the importance of having several tools for the study of burning plasma scenarios, especially in a domain that present devices cannot access experimentally. (Author)

  11. Technique for Increasing Accuracy of Positioning System of Machine Tools

    Directory of Open Access Journals (Sweden)

    Sh. Ji

    2014-01-01

    Full Text Available The aim of research is to improve the accuracy of positioning and processing system using a technique for optimization of pressure diagrams of guides in machine tools. The machining quality is directly related to its accuracy, which characterizes an impact degree of various errors of machines. The accuracy of the positioning system is one of the most significant machining characteristics, which allow accuracy evaluation of processed parts.The literature describes that the working area of the machine layout is rather informative to characterize the effect of the positioning system on the macro-geometry of the part surfaces to be processed. To enhance the static accuracy of the studied machine, in principle, two groups of measures are possible. One of them points toward a decrease of the cutting force component, which overturns the slider moments. Another group of measures is related to the changing sizes of the guide facets, which may lead to their profile change.The study was based on mathematical modeling and optimization of the cutting zone coordinates. And we find the formula to determine the surface pressure of the guides. The selected parameters of optimization are vectors of the cutting force and values of slides and guides. Obtained results show that a technique for optimization of coordinates in the cutting zone was necessary to increase a processing accuracy.The research has established that to define the optimal coordinates of the cutting zone we have to change the sizes of slides, value and coordinates of applied forces, reaching the pressure equalization and improving the accuracy of positioning system of machine tools. In different points of the workspace a vector of forces is applied, pressure diagrams are found, which take into account the changes in the parameters of positioning system, and the pressure diagram equalization to provide the most accuracy of machine tools is achieved.

  12. Least squares inversion of Stokes profiles in the presence of velocity gradients

    International Nuclear Information System (INIS)

    Skumanich, A.; Rees, D.E.; Lites, B.W.; Sacramento Peak Observatory, Sunspot, NM)

    1985-01-01

    The Auer, Heasley and House Stokes inversion procedure in use at High Altitude Observatory is based on the analytic solution of the equation of transfer for polarized light where the representation of the thermodynamic and magnetic structure of the atmosphere is assumed to have a high degree of invariance, namely, a Milne-Eddington (ME) structure with a constant magnetic field. In the presence of invariance breaking gradients the resultant Stokes profiles are represented only approximately, if at all, by analytic forms. The accuracy of the inversion parameters and their significance as measures of actual structure are explored for the ME and the Landman-Finn sunspot models under the effects of velocity gradients. The resulting field parameters are good to a few percent and prove to be insensitive to the errors committed by the use of a ME-representation, but the resulting ME parameters yield a less precise measure of thermal structure

  13. Accuracy of a computer-assisted planning and placement system for anatomical femoral tunnel positioning in anterior cruciate ligament reconstruction

    NARCIS (Netherlands)

    Luites, J.W.H.; Wymenga, A.B.; Blankevoort, L.; Eygendaal, D.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    Background Femoral tunnel positioning is a difficult, but important factor in successful anterior cruciate ligament (ACL) reconstruction. Computer navigation can improve the anatomical planning procedure besides the tunnel placement procedure. Methods The accuracy of the computer-assisted femoral

  14. Individual differences in eyewitness identification accuracy between sequential and simultaneous line-ups: consequences for police practice and jury decisions

    OpenAIRE

    Dominic Willmott; Nicole Sherretts

    2016-01-01

    Background Although previous research has indicated that sequential line-up procedures result in fewer mistaken identifications, this was found to be at the expense of accurate identifications more typical within simultaneous procedures. Hence, there remains a lack of agreement about which procedure is superior, and the interaction such procedures have with eyewitness confidence. The interaction between witness demographics and identification accuracy also remains unclear. Part...

  15. Gaussian interaction profile kernels for predicting drug-target interaction.

    Science.gov (United States)

    van Laarhoven, Twan; Nabuurs, Sander B; Marchiori, Elena

    2011-11-01

    The in silico prediction of potential interactions between drugs and target proteins is of core importance for the identification of new drugs or novel targets for existing drugs. However, only a tiny portion of all drug-target pairs in current datasets are experimentally validated interactions. This motivates the need for developing computational methods that predict true interaction pairs with high accuracy. We show that a simple machine learning method that uses the drug-target network as the only source of information is capable of predicting true interaction pairs with high accuracy. Specifically, we introduce interaction profiles of drugs (and of targets) in a network, which are binary vectors specifying the presence or absence of interaction with every target (drug) in that network. We define a kernel on these profiles, called the Gaussian Interaction Profile (GIP) kernel, and use a simple classifier, (kernel) Regularized Least Squares (RLS), for prediction drug-target interactions. We test comparatively the effectiveness of RLS with the GIP kernel on four drug-target interaction networks used in previous studies. The proposed algorithm achieves area under the precision-recall curve (AUPR) up to 92.7, significantly improving over results of state-of-the-art methods. Moreover, we show that using also kernels based on chemical and genomic information further increases accuracy, with a neat improvement on small datasets. These results substantiate the relevance of the network topology (in the form of interaction profiles) as source of information for predicting drug-target interactions. Software and Supplementary Material are available at http://cs.ru.nl/~tvanlaarhoven/drugtarget2011/. tvanlaarhoven@cs.ru.nl; elenam@cs.ru.nl. Supplementary data are available at Bioinformatics online.

  16. Partially hydrolyzed guar gum characterization and sensitive quantification in food matrices by high performance anion exchange chromatography with pulsed amperometric detection--validation using accuracy profile.

    Science.gov (United States)

    Mercier, G; Campargue, C

    2012-11-02

    Interest concerning functional ingredients and especially dietary fibres has been growing in recent years. At the same time, the variety of ingredient accepted as dietary fibres and their mixing at low level in complex matrices have considerably complicated their quantitative analysis by approved AOAC methods. These reasons have led to the specific development of an innovative analytical method performed by high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) to detect and quantify partially hydrolyzed guar gum (PHGG) in fruit preparation and dairy matrices. The analytical methodology was divided in two steps which could be deployed separately or in conjunction. The first, consists in a complete characterization of PHGG by size exclusion chromatography (SEC) with multi-angle light scattering and refractive index detection and HPAEC-PAD to determine its physico-chemical properties and galactomannans content, and the second step is the development of a new HPAEC-PAD method for PHGG direct quantification in complex matrices (dairy product). Validation in terms of detection and quantification limits, linearity of the analytical range, average accuracy (recovery, trueness) and average uncertainty were statistically carried out with accuracy profile. Overall, this new chromatographic method has considerably improved the possibility to quantify without fractionation treatment, low level of dietary fibres emerging from specific galactomannans, in complex matrices and many foodstuffs. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. The effect of sampling frequency on the accuracy of estimates of milk ...

    African Journals Online (AJOL)

    The results of this study support the five-weekly sampling procedure currently used by the South African National Dairy Cattle Performance Testing Scheme. However, replacement of proportional bulking of individual morning and evening samples with a single evening milk sample would not compromise accuracy provided ...

  18. Depth profiling of extended defects in silicon by Rutherford backscattering measurements

    International Nuclear Information System (INIS)

    Gruska, B.; Goetz, G.

    1981-01-01

    Depth profiling of dislocations and stacking faults is carried out by analyzing axial and planar channeling data from As + -and P + -implanted silicon samples annealed at high temperatures. The analyzing procedure is based on the simple two-beam model. The results show that depth profiling of dislocations using planar channeling data is connected with a broadening of the real distributions. A degradation of the defect concentration and a deformation of the profile result for very high defect concentrations (> 5 x 10 5 cm/cm 2 ). All these effects can be neglected by analyzing axial channeling data. Depth profiling of stacking faults is restricted to the determination of the depth distribution of displaced atomic rows or planes. For both the procedures, axial as well as planar channeling measurements, the same depth profiles of displaced atomic rows are obtained. (author)

  19. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  20. Design of the tool for periodic not evolvent profiles

    Directory of Open Access Journals (Sweden)

    Anisimov Roman

    2017-01-01

    Full Text Available The new approach to profiling of the tool for processing of parts with periodic not evolvent profiles are considered in the article The discriminatory analysis of periodic profiles including repetition of profile both in the plane of perpendicular axis of part, and in the plane of passing along part of axis is offered. In the basis of the offered profiling method the idea of space shaping by rated surface of product of tool surface lies. The big advantage of the offered approach in profiling is its combination with the analysis of parameters of process of engineering work. It allows to predict the accuracy and surface quality of product with not evolvent periodic profile. While using the offered approach the pinion cutter for processing of wheels with internal triangular teeths and mill for processing of the screw of the counter of consumption of liquid, complex profile of which consists of several formings, have been received

  1. Performance audit procedures for opacity monitors

    International Nuclear Information System (INIS)

    Plaisance, S.J.; Peeler, J.W.

    1987-04-01

    This manual contains monitor-specific performance audit procedures and data forms for use in conducting audits of installed opacity continuous emission monitoring systems (CEMS). General auditing procedures and acceptance limits for various audit criteria are discussed. Practical considerations and common problems encountered in conducting audits are delineated, and recommendations are included to optimize the successful completion of performance audits. Performance audit procedures and field-data forms were developed for six common opacity CEMS: (1) Lear Siegler, Inc. Model RM-41; (2) Lear Siegler, Inc. Model RM-4; (3) Dynatron Model 1100; (4) Thermo Electron, Inc. Model 400; (5) Thermo Electron, Inc. Model 1000A; and (6) Enviroplan Model D-R280 AV. Generic audit procedures are included for use in evaluating opacity CEMS with multiple transmissometers and combiner devices. In addition, several approaches for evaluating the zero-alignment or clear-path zero response are described. The zero-alignment procedures are included since the factor is fundamental to the accuracy of opacity monitoring data, even though the zero-alignment checks cannot usually be conducted during a performance audit

  2. Effects of accuracy motivation and anchoring on metacomprehension judgment and accuracy.

    Science.gov (United States)

    Zhao, Qin

    2012-01-01

    The current research investigates how accuracy motivation impacts anchoring and adjustment in metacomprehension judgment and how accuracy motivation and anchoring affect metacomprehension accuracy. Participants were randomly assigned to one of six conditions produced by the between-subjects factorial design involving accuracy motivation (incentive or no) and peer performance anchor (95%, 55%, or no). Two studies showed that accuracy motivation did not impact anchoring bias, but the adjustment-from-anchor process occurred. Accuracy incentive increased anchor-judgment gap for the 95% anchor but not for the 55% anchor, which induced less certainty about the direction of adjustment. The findings offer support to the integrative theory of anchoring. Additionally, the two studies revealed a "power struggle" between accuracy motivation and anchoring in influencing metacomprehension accuracy. Accuracy motivation could improve metacomprehension accuracy in spite of anchoring effect, but if anchoring effect is too strong, it could overpower the motivation effect. The implications of the findings were discussed.

  3. Detecting and classifying method based on similarity matching of Android malware behavior with profile.

    Science.gov (United States)

    Jang, Jae-Wook; Yun, Jaesung; Mohaisen, Aziz; Woo, Jiyoung; Kim, Huy Kang

    2016-01-01

    Mass-market mobile security threats have increased recently due to the growth of mobile technologies and the popularity of mobile devices. Accordingly, techniques have been introduced for identifying, classifying, and defending against mobile threats utilizing static, dynamic, on-device, and off-device techniques. Static techniques are easy to evade, while dynamic techniques are expensive. On-device techniques are evasion, while off-device techniques need being always online. To address some of those shortcomings, we introduce Andro-profiler, a hybrid behavior based analysis and classification system for mobile malware. Andro-profiler main goals are efficiency, scalability, and accuracy. For that, Andro-profiler classifies malware by exploiting the behavior profiling extracted from the integrated system logs including system calls. Andro-profiler executes a malicious application on an emulator in order to generate the integrated system logs, and creates human-readable behavior profiles by analyzing the integrated system logs. By comparing the behavior profile of malicious application with representative behavior profile for each malware family using a weighted similarity matching technique, Andro-profiler detects and classifies it into malware families. The experiment results demonstrate that Andro-profiler is scalable, performs well in detecting and classifying malware with accuracy greater than 98 %, outperforms the existing state-of-the-art work, and is capable of identifying 0-day mobile malware samples.

  4. Dose delivery verification and accuracy assessment of stereotaxy in stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Pelagade, S.M.; Bopche, T.T.; Namitha, K.; Munshi, M.; Bhola, S.; Sharma, H.; Patel, B.K.; Vyas, R.K.

    2008-01-01

    The outcome of stereotactic radiotherapy (SRT) and stereotactic radiosurgery (SRS) in both benign and malignant tumors within the cranial region highly depends on precision in dosimetry, dose delivery and the accuracy assessment of stereotaxy associated with the unit. The frames BRW (Brown-Roberts-Wells) and GTC (Gill- Thomas-Cosman) can facilitate accurate patient positioning as well as precise targeting of tumours. The implementation of this technique may result in a significant benefit as compared to conventional therapy. As the target localization accuracy is improved, the demand for treatment planning accuracy of a TPS is also increased. The accuracy of stereotactic X Knife treatment planning system has two components to verify: (i) the dose delivery verification and the accuracy assessment of stereotaxy; (ii) to ensure that the Cartesian coordinate system associated is well established within the TPS for accurate determination of a target position. Both dose delivery verification and target positional accuracy affect dose delivery accuracy to a defined target. Hence there is a need to verify these two components in quality assurance protocol. The main intention of this paper is to present our dose delivery verification procedure using cylindrical wax phantom and accuracy assessment (target position) of stereotaxy using Geometric Phantom on Elekta's Precise linear accelerator for stereotactic installation

  5. Comparison of RASS temperature profiles with other tropospheric soundings

    International Nuclear Information System (INIS)

    Bonino, G.; Lombardini, P.P.; Trivero, P.

    1980-01-01

    The vertical temperature profile of the lower troposphere can be measured with a radio-acoustic sounding system (RASS). A comparison of the thermal profiles measured with the RASS and with traditional methods shows a) RASS ability to produce vertical thermal profiles at an altitude range of 170 to 1000 m with temperature accuracy and height discrimination comparable with conventional soundings, b) advantages of remote sensing as offered by new sounder, c) applicability of RASS both in assessing evolution of thermodynamic conditions in PBL and in sensing conditions conducive to high concentrations of air pollutants at the ground level. (author)

  6. Accuracy of five implant impression technique: effect of splinting materials and methods

    Science.gov (United States)

    Cho, Sung-Bum

    2011-01-01

    PURPOSE The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z-axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (Pimpression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure. PMID:22259700

  7. Lessons learned from accuracy assessment of IAEA-SPE-4 experiment predictions

    International Nuclear Information System (INIS)

    Prosek, A.

    2002-01-01

    The use of methods for code accuracy assessment has strongly increased in the last years. The methods suitable to provide quantitative comparison between the thermalhydraulic code predictions and experimental measurements were proposed e.g. fast Fourier transform based method (FFTBM), stochastic approximation ratio based method (SARBM) and a few methods used in the frame of the recently developed automated code assessment program (ACAP). Further, in the frame of FFTBM also a procedure to quantify the whole calculation was proposed with averaging of the results. The problem is that averaging may hide discrepancies highlighted in the qualitative analysis when only quantitative results are published. The purpose of the study was therefore to propose additional accuracy measures. New proposed measures were tested with IAEA-SPE-4 pre- and post-test predictions. The obtained results showed that the proposed measures improve the whole picture of the code accuracy. This is important when the reader is not provided with the accompanied qualitative analysis. The study shows that proposed accuracy measures efficiently increase the confidence in the quantitative results.(author)

  8. Noise pollution mapping approach and accuracy on landscape scales.

    Science.gov (United States)

    Iglesias Merchan, Carlos; Diaz-Balteiro, Luis

    2013-04-01

    Noise mapping allows the characterization of environmental variables, such as noise pollution or soundscape, depending on the task. Strategic noise mapping (as per Directive 2002/49/EC, 2002) is a tool intended for the assessment of noise pollution at the European level every five years. These maps are based on common methods and procedures intended for human exposure assessment in the European Union that could be also be adapted for assessing environmental noise pollution in natural parks. However, given the size of such areas, there could be an alternative approach to soundscape characterization rather than using human noise exposure procedures. It is possible to optimize the size of the mapping grid used for such work by taking into account the attributes of the area to be studied and the desired outcome. This would then optimize the mapping time and the cost. This type of optimization is important in noise assessment as well as in the study of other environmental variables. This study compares 15 models, using different grid sizes, to assess the accuracy of the noise mapping of the road traffic noise at a landscape scale, with respect to noise and landscape indicators. In a study area located in the Manzanares High River Basin Regional Park in Spain, different accuracy levels (Kappa index values from 0.725 to 0.987) were obtained depending on the terrain and noise source properties. The time taken for the calculations and the noise mapping accuracy results reveal the potential for setting the map resolution in line with decision-makers' criteria and budget considerations. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Heuristic and probabilistic wind power availability estimation procedures: Improved tools for technology and site selection

    Energy Technology Data Exchange (ETDEWEB)

    Nigim, K.A. [University of Waterloo, Waterloo, Ont. (Canada). Department of Electrical and Computer Engineering; Parker, Paul [University of Waterloo, Waterloo, Ont. (Canada). Department of Geography, Environmental Studies

    2007-04-15

    The paper describes two investigative procedures to estimate wind power from measured wind velocities. Wind velocity data are manipulated to visualize the site potential by investigating the probable wind power availability and its capacity to meet a targeted demand. The first procedure is an availability procedure that looks at the wind characteristics and its probable energy capturing profile. This profile of wind enables the probable maximum operating wind velocity profile for a selected wind turbine design to be predicted. The structured procedures allow for a consequent adjustment, sorting and grouping of the measured wind velocity data taken at different time intervals and hub heights. The second procedure is the adequacy procedure that investigates the probable degree of availability and the application consequences. Both procedures are programmed using MathCAD symbolic mathematical software. The math tool is used to generate a visual interpolation of the data as well as numerical results from extensive data sets that exceed the capacity of conventional spreadsheet tools. Two sites located in Southern Ontario, Canada are investigated using the procedures. Successful implementation of the procedures supports informed decision making where a hill site is shown to have much higher wind potential than that measured at the local airport. The process is suitable for a wide spectrum of users who are considering the energy potential for either a grid-tied or off-grid wind energy system. (author)

  10. Metadata requirements for results of diagnostic imaging procedures: a BIIF profile to support user applications

    Science.gov (United States)

    Brown, Nicholas J.; Lloyd, David S.; Reynolds, Melvin I.; Plummer, David L.

    2002-05-01

    A visible digital image is rendered from a set of digital image data. Medical digital image data can be stored as either: (a) pre-rendered format, corresponding to a photographic print, or (b) un-rendered format, corresponding to a photographic negative. The appropriate image data storage format and associated header data (metadata) required by a user of the results of a diagnostic procedure recorded electronically depends on the task(s) to be performed. The DICOM standard provides a rich set of metadata that supports the needs of complex applications. Many end user applications, such as simple report text viewing and display of a selected image, are not so demanding and generic image formats such as JPEG are sometimes used. However, these are lacking some basic identification requirements. In this paper we make specific proposals for minimal extensions to generic image metadata of value in various domains, which enable safe use in the case of two simple healthcare end user scenarios: (a) viewing of text and a selected JPEG image activated by a hyperlink and (b) viewing of one or more JPEG images together with superimposed text and graphics annotation using a file specified by a profile of the ISO/IEC Basic Image Interchange Format (BIIF).

  11. On the Accuracy of Language Trees

    Science.gov (United States)

    Pompei, Simone; Loreto, Vittorio; Tria, Francesca

    2011-01-01

    Historical linguistics aims at inferring the most likely language phylogenetic tree starting from information concerning the evolutionary relatedness of languages. The available information are typically lists of homologous (lexical, phonological, syntactic) features or characters for many different languages: a set of parallel corpora whose compilation represents a paramount achievement in linguistics. From this perspective the reconstruction of language trees is an example of inverse problems: starting from present, incomplete and often noisy, information, one aims at inferring the most likely past evolutionary history. A fundamental issue in inverse problems is the evaluation of the inference made. A standard way of dealing with this question is to generate data with artificial models in order to have full access to the evolutionary process one is going to infer. This procedure presents an intrinsic limitation: when dealing with real data sets, one typically does not know which model of evolution is the most suitable for them. A possible way out is to compare algorithmic inference with expert classifications. This is the point of view we take here by conducting a thorough survey of the accuracy of reconstruction methods as compared with the Ethnologue expert classifications. We focus in particular on state-of-the-art distance-based methods for phylogeny reconstruction using worldwide linguistic databases. In order to assess the accuracy of the inferred trees we introduce and characterize two generalizations of standard definitions of distances between trees. Based on these scores we quantify the relative performances of the distance-based algorithms considered. Further we quantify how the completeness and the coverage of the available databases affect the accuracy of the reconstruction. Finally we draw some conclusions about where the accuracy of the reconstructions in historical linguistics stands and about the leading directions to improve it. PMID:21674034

  12. On the accuracy of language trees.

    Directory of Open Access Journals (Sweden)

    Simone Pompei

    Full Text Available Historical linguistics aims at inferring the most likely language phylogenetic tree starting from information concerning the evolutionary relatedness of languages. The available information are typically lists of homologous (lexical, phonological, syntactic features or characters for many different languages: a set of parallel corpora whose compilation represents a paramount achievement in linguistics. From this perspective the reconstruction of language trees is an example of inverse problems: starting from present, incomplete and often noisy, information, one aims at inferring the most likely past evolutionary history. A fundamental issue in inverse problems is the evaluation of the inference made. A standard way of dealing with this question is to generate data with artificial models in order to have full access to the evolutionary process one is going to infer. This procedure presents an intrinsic limitation: when dealing with real data sets, one typically does not know which model of evolution is the most suitable for them. A possible way out is to compare algorithmic inference with expert classifications. This is the point of view we take here by conducting a thorough survey of the accuracy of reconstruction methods as compared with the Ethnologue expert classifications. We focus in particular on state-of-the-art distance-based methods for phylogeny reconstruction using worldwide linguistic databases. In order to assess the accuracy of the inferred trees we introduce and characterize two generalizations of standard definitions of distances between trees. Based on these scores we quantify the relative performances of the distance-based algorithms considered. Further we quantify how the completeness and the coverage of the available databases affect the accuracy of the reconstruction. Finally we draw some conclusions about where the accuracy of the reconstructions in historical linguistics stands and about the leading directions to improve

  13. Suggested guidelines for the management of high-profile fatality cases.

    Science.gov (United States)

    Perper, Joshua A; Juste, Gertrude M; Schueler, Harold E; Motte, Reinhard W; Cina, Stephen J

    2008-10-01

    The investigation of high-profile fatalities poses special challenges to medical examiners and coroners. Most high-profile cases can be readily recognized early in the course of the investigation. Commonly encountered examples include police-related fatalities or deaths in custody, deaths of celebrities, and mass fatalities or clustered deaths (eg, serial killers). Medical examiner and coroner offices should have policies and procedures in place for adequately handling such cases. A rational approach to these high-profile cases includes activating medical examiner or coroner investigative teams, preplanning before the autopsy, using special autopsy techniques and toxicology procedures, skillful questioning of key witnesses, preparing detailed and comprehensive reports, and planning effective communication with the media. The investigation of the sudden and unexpected death of Anna Nicole Smith, an entertainment personality, is presented as an example of how to address the challenging issues inherent in high-profile fatalities and how to adequately prepare for the forensic investigation of high-profile cases. This article presents a methodical approach to the investigation of high-profile deaths. A comprehensive, preplanned forensic investigation and autopsy (including use of adjunctive studies) following the death of Anna Nicole Smith resulted in the accurate determination of the cause and manner of her death while adequately convincing the public of the objectivity and reliability of the Medical Examiners Office with respect to its conclusions. The forensic investigation of death in high-profile cases can be much more tedious and demanding than the investigation of routine cases. It requires more stringent safekeeping of the body and its evidence, more extensive and sophisticated dissection techniques on occasion, and exhaustive toxicologic analysis to exclude low-probability allegations. Procedures for honest, unbiased, and judicious communication with outside

  14. Reliable gene expression analysis by reverse transcription-quantitative PCR: reporting and minimizing the uncertainty in data accuracy.

    Science.gov (United States)

    Remans, Tony; Keunen, Els; Bex, Geert Jan; Smeets, Karen; Vangronsveld, Jaco; Cuypers, Ann

    2014-10-01

    Reverse transcription-quantitative PCR (RT-qPCR) has been widely adopted to measure differences in mRNA levels; however, biological and technical variation strongly affects the accuracy of the reported differences. RT-qPCR specialists have warned that, unless researchers minimize this variability, they may report inaccurate differences and draw incorrect biological conclusions. The Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines describe procedures for conducting and reporting RT-qPCR experiments. The MIQE guidelines enable others to judge the reliability of reported results; however, a recent literature survey found low adherence to these guidelines. Additionally, even experiments that use appropriate procedures remain subject to individual variation that statistical methods cannot correct. For example, since ideal reference genes do not exist, the widely used method of normalizing RT-qPCR data to reference genes generates background noise that affects the accuracy of measured changes in mRNA levels. However, current RT-qPCR data reporting styles ignore this source of variation. In this commentary, we direct researchers to appropriate procedures, outline a method to present the remaining uncertainty in data accuracy, and propose an intuitive way to select reference genes to minimize uncertainty. Reporting the uncertainty in data accuracy also serves for quality assessment, enabling researchers and peer reviewers to confidently evaluate the reliability of gene expression data. © 2014 American Society of Plant Biologists. All rights reserved.

  15. Additional measures do not improve the diagnostic accuracy of the Hospital Admission Risk Profile for detecting downstream quality of life in community-dwelling older people presenting to a hospital emergency department.

    Science.gov (United States)

    Grimmer, K; Milanese, S; Beaton, K; Atlas, A

    2014-01-01

    The Hospital Admission Risk Profile (HARP) instrument is commonly used to assess risk of functional decline when older people are admitted to hospital. HARP has moderate diagnostic accuracy (65%) for downstream decreased scores in activities of daily living. This paper reports the diagnostic accuracy of HARP for downstream quality of life. It also tests whether adding other measures to HARP improves its diagnostic accuracy. One hundred and forty-eight independent community dwelling individuals aged 65 years or older were recruited in the emergency department of one large Australian hospital with a medical problem for which they were discharged without a hospital ward admission. Data, including age, sex, primary language, highest level of education, postcode, living status, requiring care for daily activities, using a gait aid, receiving formal community supports, instrumental activities of daily living in the last week, hospitalization and falls in the last 12 months, and mental state were collected at recruitment. HARP scores were derived from a formula that summed scores assigned to age, activities of daily living, and mental state categories. Physical and mental component scores of a quality of life measure were captured by telephone interview at 1 and 3 months after recruitment. HARP scores are moderately accurate at predicting downstream decline in physical quality of life, but did not predict downstream decline in mental quality of life. The addition of other variables to HARP did not improve its diagnostic accuracy for either measure of quality of life. HARP is a poor predictor of quality of life.

  16. Use of Hi-resolution data for evaluating accuracy of traffic volume counts collected by microwave sensors

    Directory of Open Access Journals (Sweden)

    David K. Chang

    2017-10-01

    Full Text Available Over the past few years, the Utah Department of Transportation has developed the signal performance metrics (SPMs system to evaluate the performance of signalized intersections dynamically. This system currently provides data summaries for several performance measures, one of them being turning movement counts collected by microwave sensors. As this system became public, there was a need to evaluate the accuracy of the data placed on the SPMs. A large-scale data collection was carried out to meet this need. Vehicles in the Hi-resolution data from microwave sensors were matched with the vehicles by ground-truth volume count data. Matching vehicles from the microwave sensor data and the ground-truth data manually collected required significant effort. A spreadsheet-based data analysis procedure was developed to carry out the task. A mixed model analysis of variance was used to analyze the effects of the factors considered on turning volume count accuracy. The analysis found that approach volume level and number of approach lanes would have significant effect on the accuracy of turning volume counts but the location of the sensors did not significantly affect the accuracy of turning volume counts. In addition, it was found that the location of lanes in relation to the sensor did not significantly affect the accuracy of lane-by-lane volume counts. This indicated that accuracy analysis could be performed by using total approach volumes without comparing specific turning counts, that is, left-turn, through and right-turn movements. In general, the accuracy of approach volume counts collected by microwave sensors were within the margin of error that traffic engineers could accept. The procedure taken to perform the analysis and a summary of accuracy of volume counts for the factor combinations considered are presented in this paper.

  17. Effect of X-Word Grammar and Traditional Grammar Instruction on Grammatical Accuracy

    Science.gov (United States)

    Livingston, Sue; Toce, Andi; Casey, Toce; Montoya, Fernando; Hart, Bonny R.; O'Flaherty, Carmela

    2018-01-01

    This study first briefly describes an instructional approach to teaching grammar known as X-Word Grammar and then compares its effectiveness in assisting students in achieving grammatical accuracy with traditionally taught grammar. Two groups of L2 pre-college students were taught using curricula and practice procedures in two different grammar…

  18. Accuracy and Coverage of Diagnosis and Procedural Coding of Severely Injured Patients in the Finnish Hospital Discharge Register: Comparison to Patient Files and the Helsinki Trauma Registry.

    Science.gov (United States)

    Heinänen, M; Brinck, T; Handolin, L; Mattila, V M; Söderlund, T

    2017-09-01

    Discharge Register and 19 (7.6%) from the trauma registry of the Helsinki University Hospital's Trauma Unit. The validity of the Finnish Hospital Discharge Register data is unsatisfactory in terms of the accuracy and coverage of diagnoses in patients with multiple trauma diagnoses. Procedural codes provide greater accuracy. We found the coverage and accuracy of the trauma registry of the Helsinki University Hospital's Trauma Unit to be excellent. Therefore, a special trauma registry, such as the trauma registry of the Helsinki University Hospital's Trauma Unit, provides much more accurate data and should be the preferred registry when extracting data for research or for administrative use, such as resource prioritizing.

  19. Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations.

    Science.gov (United States)

    Freckmann, Guido; Schmid, Christina; Baumstark, Annette; Rutschmann, Malte; Haug, Cornelia; Heinemann, Lutz

    2015-07-01

    In the European Union (EU), the ISO (International Organization for Standardization) 15197 standard is applicable for the evaluation of systems for self-monitoring of blood glucose (SMBG) before the market approval. In 2013, a revised version of this standard was published. Relevant revisions in the analytical performance requirements are the inclusion of the evaluation of influence quantities, for example, hematocrit, and some changes in the testing procedures for measurement precision and system accuracy evaluation, for example, number of test strip lots. Regarding system accuracy evaluation, the most important change is the inclusion of more stringent accuracy criteria. In 2014, the Food and Drug Administration (FDA) in the United States published their own guidance document for the premarket evaluation of SMBG systems with even more stringent system accuracy criteria than stipulated by ISO 15197:2013. The establishment of strict accuracy criteria applicable for the premarket evaluation is a possible approach to further improve the measurement quality of SMBG systems. However, the system accuracy testing procedure is quite complex, and some critical aspects, for example, systematic measurement difference between the reference measurement procedure and a higher-order procedure, may potentially limit the apparent accuracy of a given system. Therefore, the implementation of a harmonized reference measurement procedure for which traceability to standards of higher order is verified through an unbroken, documented chain of calibrations is desirable. In addition, the establishment of regular and standardized post-marketing evaluations of distributed test strip lots should be considered as an approach toward an improved measurement quality of available SMBG systems. © 2015 Diabetes Technology Society.

  20. Criminal profiling as expert witness evidence: The implications of the profiler validity research.

    Science.gov (United States)

    Kocsis, Richard N; Palermo, George B

    The use and development of the investigative tool colloquially known as criminal profiling has steadily increased over the past five decades throughout the world. Coupled with this growth has been a diversification in the suggested range of applications for this technique. Possibly the most notable of these has been the attempted transition of the technique from a tool intended to assist police investigations into a form of expert witness evidence admissible in legal proceedings. Whilst case law in various jurisdictions has considered with mutual disinclination the evidentiary admissibility of criminal profiling, a disjunction has evolved between these judicial examinations and the scientifically vetted research testing the accuracy (i.e., validity) of the technique. This article offers an analysis of the research directly testing the validity of the criminal profiling technique and the extant legal principles considering its evidentiary admissibility. This analysis reveals that research findings concerning the validity of criminal profiling are surprisingly compatible with the extant legal principles. The overall conclusion is that a discrete form of crime behavioural analysis is supported by the profiler validity research and could be regarded as potentially admissible expert witness evidence. Finally, a number of theoretical connections are also identified concerning the skills and qualifications of individuals who may feasibly provide such expert testimony. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Inverse modeling applied to Scanning Capacitance Microscopy for improved spatial resolution and accuracy

    International Nuclear Information System (INIS)

    McMurray, J. S.; Williams, C. C.

    1998-01-01

    Scanning Capacitance Microscopy (SCM) is capable of providing two-dimensional information about dopant and carrier concentrations in semiconducting devices. This information can be used to calibrate models used in the simulation of these devices prior to manufacturing and to develop and optimize the manufacturing processes. To provide information for future generations of devices, ultra-high spatial accuracy (<10 nm) will be required. One method, which potentially provides a means to obtain these goals, is inverse modeling of SCM data. Current semiconducting devices have large dopant gradients. As a consequence, the capacitance probe signal represents an average over the local dopant gradient. Conversion of the SCM signal to dopant density has previously been accomplished with a physical model which assumes that no dopant gradient exists in the sampling area of the tip. The conversion of data using this model produces results for abrupt profiles which do not have adequate resolution and accuracy. A new inverse model and iterative method has been developed to obtain higher resolution and accuracy from the same SCM data. This model has been used to simulate the capacitance signal obtained from one and two-dimensional ideal abrupt profiles. This simulated data has been input to a new iterative conversion algorithm, which has recovered the original profiles in both one and two dimensions. In addition, it is found that the shape of the tip can significantly impact resolution. Currently SCM tips are found to degrade very rapidly. Initially the apex of the tip is approximately hemispherical, but quickly becomes flat. This flat region often has a radius of about the original hemispherical radius. This change in geometry causes the silicon directly under the disk to be sampled with approximately equal weight. In contrast, a hemispherical geometry samples most strongly the silicon centered under the SCM tip and falls off quickly with distance from the tip's apex. Simulation

  2. A simplified hazard audit procedures guide

    International Nuclear Information System (INIS)

    Harrison, D.G.; Tabatabai, A.S.; Scott, W.B.; Murphy, K.J.

    1991-02-01

    As part of on-going technical support services to the US Department of Energy (DOE), Battelle Pacific Northwest Laboratory (PNL) has developed a simplified hazard audit procedures guide which enables cost-effective and timely assessment and characterization of the DOE nuclear (reactor and nonreactor) and non-nuclear facilities safety profile

  3. Performance evaluation and accuracy of passive capillary samplers (PCAPs) for estimating real-time drainage water fluxes

    Science.gov (United States)

    Successful monitoring of pollutant transport through the soil profile requires accurate, reliable, and appropriate instrumentation to measure amount of drainage water or flux within the vadose layer. We evaluated the performance and accuracy of automated passive capillary wick samplers (PCAPs) for ...

  4. Emergency Physician Awareness of Prehospital Procedures and Medications

    Directory of Open Access Journals (Sweden)

    Rachel Waldron

    2014-07-01

    Full Text Available Introduction: Maintaining patient safety during transition from prehospital to emergency department (ED care depends on effective handoff communication between providers. We sought to determine emergency physicians’ (EP knowledge of the care provided by paramedics in terms of both procedures and medications, and whether the use of a verbal report improved physician accuracy. Methods: We conducted a 2-phase observational survey of a convenience sample of EPs in an urban, academic ED. In this large ED paramedics have no direct contact with physicians for non-critical patients, giving their report instead to the triage nurse. In Phase 1, paramedics gave verbal report to the triage nurse only. In Phase 2, a research assistant (RA stationed in triage listened to this report and then repeated it back verbatim to the EPs caring for the patient. The RA then queried the EPs 90 minutes later regarding their patients’ prehospital procedures and medications. We compared the accuracy of these 2 reporting methods. Results: There were 163 surveys completed in Phase 1 and 116 in Phase 2. The oral report had no effect on EP awareness that the patient had been brought in by ambulance (86% in Phase 1 and 85% in Phase 2. The oral report did improve EP awareness of prehospital procedures, from 16% in Phase 1 to 45% in Phase 2, OR=4.28 (2.5-7.5. EPs were able to correctly identify all oral medications in 18% of Phase 1 cases and 47% of Phase 2 cases, and all IV medications in 42% of Phase 1 cases and 50% of Phase 2 cases. The verbal report led to a mild improvement in physician awareness of oral medications given, OR=4.0 (1.09-14.5, and no improvement in physician awareness of IV medications given, OR=1.33 (0.15-11.35. Using a composite score of procedures plus oral plus IV medications, physicians had all three categories correct in 15% of Phase 1 and 39% of Phase 2 cases (p<0.0001. Conclusion: EPs in our ED were unaware of many prehospital procedures and

  5. Accuracy Improvement of Discharge Measurement with Modification of Distance Made Good Heading

    Directory of Open Access Journals (Sweden)

    Jongkook Lee

    2016-01-01

    Full Text Available Remote control boats equipped with an Acoustic Doppler Current Profiler (ADCP are widely accepted and have been welcomed by many hydrologists for water discharge, velocity profile, and bathymetry measurements. The advantages of this technique include high productivity, fast measurements, operator safety, and high accuracy. However, there are concerns about controlling and operating a remote boat to achieve measurement goals, especially during extreme events such as floods. When performing river discharge measurements, the main error source stems from the boat path. Due to the rapid flow in a flood condition, the boat path is not regular and this can cause errors in discharge measurements. Therefore, improvement of discharge measurements requires modification of boat path. As a result, the measurement errors in flood flow conditions are 12.3–21.8% before the modification of boat path, but 1.2–3.7% after the DMG modification of boat path. And it is considered that the modified discharges are very close to the observed discharge in the flood flow conditions. In this study, through the distance made good (DMG modification of the boat path, a comprehensive discharge measurement with high accuracy can be achieved.

  6. HOLISTIC PROCEDURE WORK ORGANIZATION AND LABOR SKILLS

    Directory of Open Access Journals (Sweden)

    Marianela Bermejo-Salmon

    2016-01-01

    Full Text Available The purpose of this article is the development of a procedure with a holistic focus for the treatment of the elements that conform the profile of work organization in the United of Base Enterprise Mastor of the Telex Company of Santiago de Cuba. Different methods and techniques are used such as: historical-logical, analysis and synthesis, induction and deduction, the Delphi method, functional analysis, integrated focus or ¨Holistic¨, experts’ approach, briefcase or portfolio of evidences, surveys, and observation of the acting, among others. The procedure establishes two key moments for the study of the process given by the level of competitions and its profile. The competence tasks were identified and the rules and standards tasks from which a direct link between the performances evaluations and formations action is established, in correspondence with the elements that integrate the process of work organization with an integrative character. 

  7. Military Publications, Index of Test Operations Procedures

    Science.gov (United States)

    1981-10-01

    serial number, aad design information for majur components. Prescribes vehicle, major component, and system descrip- tive elements required; such as...mount operating characteristics. Discusses preparation for test, instrumentation, and facil- ities. Describes procedures for force measurement, carriage...backlash and accuracy, turret friction, gun balance, manual handcrank force , manual response ratio, weapon and sighting system backlash, power controller

  8. Verification procedures of ultrasonic flow meters for natural gas applications; Procedimento de verificacao de medidores ultra-sonicos para gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Lourenco, Tulio C. [TRANSPETRO, Rio de Janeiro, RJ (Brazil)

    2009-12-19

    In recent years, the use of ultrasonic flow meters for natural gas applications has grown significantly, especially after the issuance of AGA Report 9 and AGA Report 10. The reasons this technology has stood out from the others, such as orifice-plates or turbines, are: accuracy, wide range ability, it is bi-directional, robustness, low maintenance and, mainly, integrated diagnostic parameters, such as sound velocity, signal quality and profile velocity analysis. TRANSPETRO currently operates 56 ultrasonic natural gas flow-meter systems. For operational control applications, 90% of the meters are ultrasonic, of which 85% are provided with internal diagnostic tools through the manufacturer's software. Within this perspective, it is essential and unquestionable that there are procedures and routines for ultrasonic flow-meter verification and analysis, in order to monitor their performance and integrity, in addition to the early identification of potential problems. This paper discusses the practical application of several tools and diagnostic parameters inherent in ultrasonic flow meters in periodical verifications using TRANSPETRO's procedure. (author)

  9. Determination of wall shear stress from mean velocity and Reynolds shear stress profiles

    Science.gov (United States)

    Volino, Ralph J.; Schultz, Michael P.

    2018-03-01

    An analytical method is presented for determining the Reynolds shear stress profile in steady, two-dimensional wall-bounded flows using the mean streamwise velocity. The method is then utilized with experimental data to determine the local wall shear stress. The procedure is applicable to flows on smooth and rough surfaces with arbitrary pressure gradients. It is based on the streamwise component of the boundary layer momentum equation, which is transformed into inner coordinates. The method requires velocity profiles from at least two streamwise locations, but the formulation of the momentum equation reduces the dependence on streamwise gradients. The method is verified through application to laminar flow solutions and turbulent DNS results from both zero and nonzero pressure gradient boundary layers. With strong favorable pressure gradients, the method is shown to be accurate for finding the wall shear stress in cases where the Clauser fit technique loses accuracy. The method is then applied to experimental data from the literature from zero pressure gradient studies on smooth and rough walls, and favorable and adverse pressure gradient cases on smooth walls. Data from very near the wall are not required for determination of the wall shear stress. Wall friction velocities obtained using the present method agree with those determined in the original studies, typically to within 2%.

  10. Determining a carbohydrate profile for Hansenula polymorpha

    Science.gov (United States)

    Petersen, G. R.

    1985-01-01

    The determination of the levels of carbohydrates in the yeast Hansenula polymorpha required the development of new analytical procedures. Existing fractionation and analytical methods were adapted to deal with the problems involved with the lysis of whole cells. Using these new procedures, the complete carbohydrate profiles of H. polymorpha and selected mutant strains were determined and shown to correlate favourably with previously published results.

  11. Refinement procedure for the image alignment in high-resolution electron tomography

    International Nuclear Information System (INIS)

    Houben, L.; Bar Sadan, M.

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: → Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. → Marker-free, independent of object, little user interaction. → Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  12. Satellite-derived vertical profiles of temperature and dew point for mesoscale weather forecast

    Science.gov (United States)

    Masselink, Thomas; Schluessel, P.

    1995-12-01

    Weather forecast-models need spatially high resolutioned vertical profiles of temperature and dewpoint for their initialisation. These profiles can be supplied by a combination of data from the Tiros-N Operational Vertical Sounder (TOVS) and the imaging Advanced Very High Resolution Radiometer (AVHRR) on board the NOAA polar orbiting sate!- lites. In cloudy cases the profiles derived from TOVS data only are of insufficient accuracy. The stanthrd deviations from radiosonde ascents or numerical weather analyses likely exceed 2 K in temperature and 5Kin dewpoint profiles. It will be shown that additional cloud information as retrieved from AVHIRR allows a significant improvement in theaccuracy of vertical profiles. The International TOVS Processing Package (ITPP) is coupled to an algorithm package called AVHRR Processing scheme Over cLouds, Land and Ocean (APOLLO) where parameters like cloud fraction and cloud-top temperature are determined with higher accuracy than obtained from TOVS retrieval alone. Furthermore, a split-window technique is applied to the cloud-free AVHRR imagery in order to derive more accurate surface temperatures than can be obtained from the pure TOVS retrieval. First results of the impact of AVHRR cloud detection on the quality of the profiles are presented. The temperature and humidity profiles of different retrieval approaches are validated against analyses of the European Centre for Medium-Range Weatherforecasts.

  13. Target Price Accuracy

    Directory of Open Access Journals (Sweden)

    Alexander G. Kerl

    2011-04-01

    Full Text Available This study analyzes the accuracy of forecasted target prices within analysts’ reports. We compute a measure for target price forecast accuracy that evaluates the ability of analysts to exactly forecast the ex-ante (unknown 12-month stock price. Furthermore, we determine factors that explain this accuracy. Target price accuracy is negatively related to analyst-specific optimism and stock-specific risk (measured by volatility and price-to-book ratio. However, target price accuracy is positively related to the level of detail of each report, company size and the reputation of the investment bank. The potential conflicts of interests between an analyst and a covered company do not bias forecast accuracy.

  14. Differences in metabolite profiles caused by pre-analytical blood processing procedures.

    Science.gov (United States)

    Nishiumi, Shin; Suzuki, Makoto; Kobayashi, Takashi; Yoshida, Masaru

    2018-05-01

    Recently, the use of metabolomic analysis of human serum and plasma for biomarker discovery and disease diagnosis in clinical studies has been increasing. The feasibility of using a metabolite biomarker for disease diagnosis is strongly dependent on the metabolite's stability during pre-analytical blood processing procedures, such as serum or plasma sampling and sample storage prior to centrifugation. However, the influence of blood processing procedures on the stability of metabolites has not been fully characterized. In the present study, we compared the levels of metabolites in matched human serum and plasma samples using gas chromatography coupled with mass spectrometry and liquid chromatography coupled with mass spectrometry. In addition, we evaluated the changes in plasma metabolite levels induced by storage at room temperature or at a cold temperature prior to centrifugation. As a result, it was found that 76 metabolites exhibited significant differences between their serum and plasma levels. Furthermore, the pre-centrifugation storage conditions significantly affected the plasma levels of 45 metabolites. These results highlight the importance of blood processing procedures during metabolome analysis, which should be considered during biomarker discovery and the subsequent use of biomarkers for disease diagnosis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  15. Accuracy optimization of high-speed AFM measurements using Design of Experiments

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, F.; Hansen, Hans Nørgaard

    2010-01-01

    Atomic Force Microscopy (AFM) is being increasingly employed in industrial micro/nano manufacturing applications and integrated into production lines. In order to achieve reliable process and product control at high measuring speed, instrument optimization is needed. Quantitative AFM measurement...... results are influenced by a number of scan settings parameters, defining topography sampling and measurement time: resolution (number of profiles and points per profile), scan range and direction, scanning force and speed. Such parameters are influencing lateral and vertical accuracy and, eventually......, the estimated dimensions of measured features. The definition of scan settings is based on a comprehensive optimization that targets maximization of information from collected data and minimization of measurement uncertainty and scan time. The Design of Experiments (DOE) technique is proposed and applied...

  16. Assessing the Accuracy and Consistency of Language Proficiency Classification under Competing Measurement Models

    Science.gov (United States)

    Zhang, Bo

    2010-01-01

    This article investigates how measurement models and statistical procedures can be applied to estimate the accuracy of proficiency classification in language testing. The paper starts with a concise introduction of four measurement models: the classical test theory (CTT) model, the dichotomous item response theory (IRT) model, the testlet response…

  17. SIMS analyses of ultra-low-energy B ion implants in Si: Evaluation of profile shape and dose accuracy

    International Nuclear Information System (INIS)

    Magee, C.W.; Hockett, R.S.; Bueyueklimanli, T.H.; Abdelrehim, I.; Marino, J.W.

    2007-01-01

    Numerous experimental studies for near-surface analyses of B in Si have shown that the B distribution within the top few nanometers is distorted by secondary ion mass spectrometry (SIMS) depth profiling with O 2 -flooding or normal incidence O 2 bombardment. Furthermore, the presence of surface oxide affects the X j determination as well as B profile shape when SIMS analyses are conducted while fully oxidizing the analytical area. Nuclear techniques such as elastic recoil detection (ERD), nuclear reaction analysis (NRA), and high-resolution Rutherford backscattering spectrometry (HR-RBS), are known to provide a profile shape near the surface that is free of artifacts. Comparisons with SIMS analyses have shown that SIMS analyses without fully oxidizing the analytical area agree well with these techniques at sufficiently high concentrations (where the nuclear techniques are applicable). The ability to measure both the B profile and an oxide marker with this non-oxidizing SIMS technique also allows accurate positioning of the B profile with respect to the SiO 2 /Si interface. This SIMS analysis protocol has been used to study the differences in near-surface dopant distribution for plasma-based implants. This study specifically focuses on measuring near-surface profile shapes as well as total implant doses for ultra-shallow B implants in Si especially those made with high peak B concentrations

  18. Accurate and robust phylogeny estimation based on profile distances: a study of the Chlorophyceae (Chlorophyta

    Directory of Open Access Journals (Sweden)

    Rahmann Sven

    2004-06-01

    Full Text Available Abstract Background In phylogenetic analysis we face the problem that several subclade topologies are known or easily inferred and well supported by bootstrap analysis, but basal branching patterns cannot be unambiguously estimated by the usual methods (maximum parsimony (MP, neighbor-joining (NJ, or maximum likelihood (ML, nor are they well supported. We represent each subclade by a sequence profile and estimate evolutionary distances between profiles to obtain a matrix of distances between subclades. Results Our estimator of profile distances generalizes the maximum likelihood estimator of sequence distances. The basal branching pattern can be estimated by any distance-based method, such as neighbor-joining. Our method (profile neighbor-joining, PNJ then inherits the accuracy and robustness of profiles and the time efficiency of neighbor-joining. Conclusions Phylogenetic analysis of Chlorophyceae with traditional methods (MP, NJ, ML and MrBayes reveals seven well supported subclades, but the methods disagree on the basal branching pattern. The tree reconstructed by our method is better supported and can be confirmed by known morphological characters. Moreover the accuracy is significantly improved as shown by parametric bootstrap.

  19. Office-based procedures for diagnosis and treatment of esophageal pathology.

    Science.gov (United States)

    Wellenstein, David J; Schutte, Henrieke W; Marres, Henri A M; Honings, Jimmie; Belafsky, Peter C; Postma, Gregory N; Takes, Robert P; van den Broek, Guido B

    2017-09-01

    Diagnostic and therapeutic office-based procedures under topical anesthesia are emerging in the daily practice of laryngologists and head and neck surgeons. Since the introduction of the transnasal esophagoscope, office-based procedures for the esophagus are increasingly performed. We conducted a systematic review of literature on office-based procedures under topical anesthesia for the esophagus. Transnasal esophagoscopy is an extensively investigated office-based procedure. This procedure shows better patient tolerability and equivalent accuracy compared to conventional transoral esophagoscopy, as well as time and cost savings. Secondary tracheoesophageal puncture, esophageal dilatation, esophageal sphincter injection, and foreign body removal are less investigated, but show promising results. With the introduction of the transnasal esophagoscope, an increasing number of diagnostic and therapeutic office-based procedures for the esophagus are possible, with multiple advantages. Further investigation must prove the clinical feasibility and effectiveness of the therapeutic office-based procedures. © 2017 Wiley Periodicals, Inc.

  20. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  1. On the choice of lens density profile in time delay cosmography

    Science.gov (United States)

    Sonnenfeld, Alessandro

    2018-03-01

    Time delay lensing is a mature and competitive cosmological probe. However, it is limited in accuracy by the well-known problem of the mass-sheet degeneracy: too rigid assumptions on the density profile of the lens can potentially bias the inference on cosmological parameters. I investigate the degeneracy between the choice of the lens density profile and the inference on the Hubble constant, focusing on double image systems. By expanding lensing observables in terms of the local derivatives of the lens potential around the Einstein radius, and assuming circular symmetry, I show that 3 degrees of freedom in the radial direction are necessary to achieve a few per cent accuracy in the time-delay distance. Additionally, while the time delay is strongly dependent on the second derivative of the potential, observables typically used to constrain lens models in time-delay studies, such as image position and radial magnification information, are mostly sensitive to the first and third derivatives, making it very challenging to accurately determine time-delay distances with lensing data alone. Tests on mock observations show that the assumption of a power-law density profile results in a 5 per cent average bias on H0, with a 6 per cent scatter. Using a more flexible model and adding unbiased velocity dispersion constraints allows me to obtain an inference with 1 per cent accuracy. A power-law model can still provide 3 per cent accuracy if velocity dispersion measurements are used to constrain its slope. Although this study is based on the assumption of axisymmetry, its main findings can be generalized to cases with moderate ellipticity.

  2. Electrical Procedures and Environmental Control Systems. Building Maintenance. Module IV. Instructor's Guide.

    Science.gov (United States)

    Sloan, Garry

    This curriculum guide, one of six modules keyed to the building maintenance competency profile developed by industry and education professionals, provides materials for two units on electrical procedures and environmental control systems. Unit 1, on electrical procedures, includes the following lessons: electrical safety; troubleshooting and…

  3. High-Accuracy Spherical Near-Field Measurements for Satellite Antenna Testing

    DEFF Research Database (Denmark)

    Breinbjerg, Olav

    2017-01-01

    The spherical near-field antenna measurement technique is unique in combining several distinct advantages and it generally constitutes the most accurate technique for experimental characterization of radiation from antennas. From the outset in 1970, spherical near-field antenna measurements have...... matured into a well-established technique that is widely used for testing antennas for many wireless applications. In particular, for high-accuracy applications, such as remote sensing satellite missions in ESA's Earth Observation Programme with uncertainty requirements at the level of 0.05dB - 0.10d......B, the spherical near-field antenna measurement technique is generally superior. This paper addresses the means to achieving high measurement accuracy; these include the measurement technique per se, its implementation in terms of proper measurement procedures, the use of uncertainty estimates, as well as facility...

  4. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P. (Dept. of Spinal Surgery, Xian Red Cross Hospital, Xian Shaanxi (China)), email: zqpddn1@gmail.com; Sun, H.H. (Dept. of Orthopaedic, Tangdu Hospital, Fourth Military Medical Univ., Xian Shaanxi (China)); Jiang, Y.H. (Dept. of Radiology, Xian Red Cross Hospital, Xian Shaanxi (China))

    2011-11-15

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  5. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    International Nuclear Information System (INIS)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P.; Sun, H.H.; Jiang, Y.H.

    2011-01-01

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  6. Tropospheric profiles of wet refractivity and humidity from the combination of remote sensing data sets and measurements on the ground

    Directory of Open Access Journals (Sweden)

    F. Hurter

    2013-11-01

    Full Text Available We reconstruct atmospheric wet refractivity profiles for the western part of Switzerland with a least-squares collocation approach from data sets of (a zenith path delays that are a byproduct of the GPS (global positioning system processing, (b ground meteorological measurements, (c wet refractivity profiles from radio occultations whose tangent points lie within the study area, and (d radiosonde measurements. Wet refractivity is a parameter partly describing the propagation of electromagnetic waves and depends on the atmospheric parameters temperature and water vapour pressure. In addition, we have measurements of a lower V-band microwave radiometer at Payerne. It delivers temperature profiles at high temporal resolution, especially in the range from ground to 3000 m a.g.l., though vertical information content decreases with height. The temperature profiles together with the collocated wet refractivity profiles provide near-continuous dew point temperature or relative humidity profiles at Payerne for the study period from 2009 to 2011. In the validation of the humidity profiles, we adopt a two-step procedure. We first investigate the reconstruction quality of the wet refractivity profiles at the location of Payerne by comparing them to wet refractivity profiles computed from radiosonde profiles available for that location. We also assess the individual contributions of the data sets to the reconstruction quality and demonstrate a clear benefit from the data combination. Secondly, the accuracy of the conversion from wet refractivity to dew point temperature and relative humidity profiles with the radiometer temperature profiles is examined, comparing them also to radiosonde profiles. For the least-squares collocation solution combining GPS and ground meteorological measurements, we achieve the following error figures with respect to the radiosonde reference: maximum median offset of relative refractivity error is −16% and quartiles are 5% to

  7. Rigorous accuracy assessment for 3D reconstruction using time-series Dual Fluoroscopy (DF) image pairs

    Science.gov (United States)

    Al-Durgham, Kaleel; Lichti, Derek D.; Kuntze, Gregor; Ronsky, Janet

    2017-06-01

    High-speed biplanar videoradiography, or clinically referred to as dual fluoroscopy (DF), imaging systems are being used increasingly for skeletal kinematics analysis. Typically, a DF system comprises two X-ray sources, two image intensifiers and two high-speed video cameras. The combination of these elements provides time-series image pairs of articulating bones of a joint, which permits the measurement of bony rotation and translation in 3D at high temporal resolution (e.g., 120-250 Hz). Assessment of the accuracy of 3D measurements derived from DF imaging has been the subject of recent research efforts by several groups, however with methodological limitations. This paper presents a novel and simple accuracy assessment procedure based on using precise photogrammetric tools. We address the fundamental photogrammetry principles for the accuracy evaluation of an imaging system. Bundle adjustment with selfcalibration is used for the estimation of the system parameters. The bundle adjustment calibration uses an appropriate sensor model and applies free-network constraints and relative orientation stability constraints for a precise estimation of the system parameters. A photogrammetric intersection of time-series image pairs is used for the 3D reconstruction of a rotating planar object. A point-based registration method is used to combine the 3D coordinates from the intersection and independently surveyed coordinates. The final DF accuracy measure is reported as the distance between 3D coordinates from image intersection and the independently surveyed coordinates. The accuracy assessment procedure is designed to evaluate the accuracy over the full DF image format and a wide range of object rotation. Experiment of reconstruction of a rotating planar object reported an average positional error of 0.44 +/- 0.2 mm in the derived 3D coordinates (minimum 0.05 and maximum 1.2 mm).

  8. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  9. Accuracy of Genomic Prediction in Switchgrass (Panicum virgatum L. Improved by Accounting for Linkage Disequilibrium

    Directory of Open Access Journals (Sweden)

    Guillaume P. Ramstein

    2016-04-01

    Full Text Available Switchgrass is a relatively high-yielding and environmentally sustainable biomass crop, but further genetic gains in biomass yield must be achieved to make it an economically viable bioenergy feedstock. Genomic selection (GS is an attractive technology to generate rapid genetic gains in switchgrass, and meet the goals of a substantial displacement of petroleum use with biofuels in the near future. In this study, we empirically assessed prediction procedures for genomic selection in two different populations, consisting of 137 and 110 half-sib families of switchgrass, tested in two locations in the United States for three agronomic traits: dry matter yield, plant height, and heading date. Marker data were produced for the families’ parents by exome capture sequencing, generating up to 141,030 polymorphic markers with available genomic-location and annotation information. We evaluated prediction procedures that varied not only by learning schemes and prediction models, but also by the way the data were preprocessed to account for redundancy in marker information. More complex genomic prediction procedures were generally not significantly more accurate than the simplest procedure, likely due to limited population sizes. Nevertheless, a highly significant gain in prediction accuracy was achieved by transforming the marker data through a marker correlation matrix. Our results suggest that marker-data transformations and, more generally, the account of linkage disequilibrium among markers, offer valuable opportunities for improving prediction procedures in GS. Some of the achieved prediction accuracies should motivate implementation of GS in switchgrass breeding programs.

  10. Profiling hydrogen in materials using ion beams

    International Nuclear Information System (INIS)

    Ziegler, J.F.; Wu, C.P.; Williams, P.

    1977-01-01

    Over the last few years many ion beam techniques have been reported for the profiling of hydrogen in materials. Nine of these were evaluated using similar samples of hydrogen ion-implanted into silicon. When possible the samples were analyzed using two or more techniques to confirm the ion-implanted accuracy. The results of this analysis which has produced a consensus profile of H in silicon which is useful as a calibration standard are reported. The analytical techniques used have capabilities ranging from very high depth resolution (approximately 50 A) and high sensitivity (less than 1 ppM) to deep probes for hydrogen which can sample throughout thin sheets

  11. Determination of the ion thermal diffusivity from neutron emission profiles in decay

    International Nuclear Information System (INIS)

    Sasao, M.; Adams, J.M.; Conroy, S.; Jarvis, O.N.; Marcus, F.B.; Sadler, G.; Belle, P. van

    1994-01-01

    Spatial profiles of the neutron emission from deuterium plasmas are routinely obtained at the Joint European Torus (JET) using the line-integrated signals measured with a multichannel instrument. It is shown that the manner in which these profiles relax following the termination of strong heating with neutral beam injection (NBI) permits the local thermal diffusivity (χ i ) to be obtained with an accuracy of about 20%. (author)

  12. Phase accuracy evaluation for phase-shifting fringe projection profilometry based on uniform-phase coded image

    Science.gov (United States)

    Zhang, Chunwei; Zhao, Hong; Zhu, Qian; Zhou, Changquan; Qiao, Jiacheng; Zhang, Lu

    2018-06-01

    Phase-shifting fringe projection profilometry (PSFPP) is a three-dimensional (3D) measurement technique widely adopted in industry measurement. It recovers the 3D profile of measured objects with the aid of the fringe phase. The phase accuracy is among the dominant factors that determine the 3D measurement accuracy. Evaluation of the phase accuracy helps refine adjustable measurement parameters, contributes to evaluating the 3D measurement accuracy, and facilitates improvement of the measurement accuracy. Although PSFPP has been deeply researched, an effective, easy-to-use phase accuracy evaluation method remains to be explored. In this paper, methods based on the uniform-phase coded image (UCI) are presented to accomplish phase accuracy evaluation for PSFPP. These methods work on the principle that the phase value of a UCI can be manually set to be any value, and once the phase value of a UCI pixel is the same as that of a pixel of a corresponding sinusoidal fringe pattern, their phase accuracy values are approximate. The proposed methods provide feasible approaches to evaluating the phase accuracy for PSFPP. Furthermore, they can be used to experimentally research the property of the random and gamma phase errors in PSFPP without the aid of a mathematical model to express random phase error or a large-step phase-shifting algorithm. In this paper, some novel and interesting phenomena are experimentally uncovered with the aid of the proposed methods.

  13. New graft sizing rings for aortic valve reimplantation procedures.

    Science.gov (United States)

    Jelenc, Matija; Jelenc, Blaž; Kneževic, Ivan; Klokocovnik, Tomislav

    2018-01-01

    The objective was to design sizing rings that would enable proper sizing of the graft in reimplantation procedures and to perform leaflet repair before graft implantation. The rings were designed in Autodesk Fusion 360 (San Rafael, CA, USA) and 3D printed using a commercial online 3D printing service. We designed incomplete rings with a low profile and complete rings with a high profile. The complete rings are best suited for reimplantation procedures, whereas low profile C rings are intended for isolated aortic valve repair, where the ascending aorta is not transected. The rings come in sizes corresponding to Vascutek Gelweave graft sizes (Vascutek Terumo, Renfrewshire, Scotland). The ring internal diameters are 5% larger than the designated ring sizes and account for the 5% stretch of the grafts when pressurized. Blades of the rings are placed at 20° intervals. The slits between the blades are designed in such a way that the commissural U-sutures, when put in place and under tension, will lock the ring in position. The rings were successfully used in 10 of our latest reimplantation procedures. After dissection of the aortic root, the commissures were suspended with U-stitches and then the ring was seated onto them. Complete leaflet repair with plication to achieve adequate effective height was then performed, followed by graft implantation. No additional leaflet repair was needed. The newly designed sizing rings enable proper sizing of the graft in reimplantation procedures and enable complete leaflet repair before graft implantation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Development of a procedure to model high-resolution wind profiles from smoothed or low-frequency data

    Science.gov (United States)

    Camp, D. W.

    1977-01-01

    The derivation of simulated Jimsphere wind profiles from low-frequency rawinsonde data and a generated set of white noise data are presented. A computer program is developed to model high-resolution wind profiles based on the statistical properties of data from the Kennedy Space Center, Florida. Comparison of the measured Jimsphere data, rawinsonde data, and the simulated profiles shows excellent agreement.

  15. Strategy for fitting source strength and reconstruction procedure in radioactive particle tracking

    International Nuclear Information System (INIS)

    Mosorov, Volodymyr

    2015-01-01

    The Radioactive Particle Tracking (RPT) technique is widely applied to study the dynamic properties of flows inside a reactor. Usually, a single radioactive particle that is neutrally buoyant with respect to the phase is used as a tracker. The particle moves inside a 3D volume of interest, and its positions are determined by an array of scintillation detectors, which count the incoming photons. The particle position coordinates are calculated by using a reconstruction procedure that solves a minimization problem between the measured counts and calibration data. Although previous studies have described the influence of specified factors on the RPT resolution and sensitivities, the question of how to choose an appropriate source strength and reconstruction procedure for the given RPT setup remains an unsolved problem. This work describes and applies the original strategy for fitting both the source strength and the sampling time interval to a specified RPT setup to guarantee a required accuracy of measurements. Additionally, the measurement accuracy of an RPT setup can be significantly increased by changing the reconstruction procedure. The results of the simulations, based on the Monte Carlo approach, have demonstrated that the proposed strategy allows for the successful implementation of the As Low As Reasonably Achievable (ALARA) principle when designing the RPT setup. The limitations and drawbacks of the proposed procedure are also presented. - Highlights: • We develop an original strategy for fitting source strength and measurement time interval in radioactive particle tracking (RPT) technique. • The proposed strategy allows successfully to implement the ALAPA (As Low As Reasonably Achievable) principle in designing of a RPT setup. • Measurement accuracy of a RPT setup can be significantly increased by improvement of the reconstruction procedure. • The algorithm can be applied to monitor the motion of the radioactive tracer in a reactor

  16. Explained variation and predictive accuracy in general parametric statistical models: the role of model misspecification

    DEFF Research Database (Denmark)

    Rosthøj, Susanne; Keiding, Niels

    2004-01-01

    When studying a regression model measures of explained variation are used to assess the degree to which the covariates determine the outcome of interest. Measures of predictive accuracy are used to assess the accuracy of the predictions based on the covariates and the regression model. We give a ...... a detailed and general introduction to the two measures and the estimation procedures. The framework we set up allows for a study of the effect of misspecification on the quantities estimated. We also introduce a generalization to survival analysis....

  17. Ionization profile of beta radiation from radioactive cloud; Jonizacioni profil beta zracenja radioaktivnog oblaka

    Energy Technology Data Exchange (ETDEWEB)

    Vujovic, M [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia); Vojvodic, V [VTI Belgrade (Yugoslavia)

    1978-07-01

    A method for calculation of the ionization profile induced by beta radiation from a radioactive cloud is given. The procedure can be applied for high altitudes of the could (H 75 km) as well as for lower ones, when the thickness of the cloud must be taken into account. The final result is given in the analytical form. (author)

  18. Surface detail reproduction and dimensional accuracy of stone models: influence of disinfectant solutions and alginate impression materials.

    Science.gov (United States)

    Guiraldo, Ricardo Danil; Borsato, Thaís Teixeira; Berger, Sandrine Bittencourt; Lopes, Murilo Baena; Gonini, Alcides; Sinhoreti, Mário Alexandre Coelho

    2012-01-01

    This study compared the surface detail reproduction and dimensional accuracy of stone models obtained from molds disinfected with 2% sodium hypochlorite, 2% chlorhexidine digluconate or 0.2% peracetic acid to models produced using molds which were not disinfected, with 3 alginate materials (Cavex ColorChange, Hydrogum 5 and Jeltrate Plus). The molds were prepared over matrix containing 20-, 50-, and 75-µm lines, performed under pressure with perforated metal tray. The molds were removed following gelation and either disinfected (using one of the solutions by spraying followed by storage in closed jars for 15 min) or not disinfected. The samples were divided into 12 groups (n=5). Molds were filled with dental gypsum Durone IV and 1 h after the start of the stone mixing the models were separated from the tray. Surface detail reproduction and dimensional accuracy were evaluated using optical microscopy on the 50-µm line with 25 mm in length, in accordance with the ISO 1563 standard. The dimensional accuracy results (%) were subjected to ANOVA. The 50 µm-line was completely reproduced by all alginate impression materials regardless of the disinfection procedure. There was no statistically significant difference in the mean values of dimensional accuracy in combinations between disinfectant procedure and alginate impression material (p=0.2130) or for independent factors. The disinfectant solutions and alginate materials used in this study are no factors of choice regarding the surface detail reproduction and dimensional accuracy of stone models.

  19. Further experiments for mean velocity profile of pipe flow at high Reynolds number

    Science.gov (United States)

    Furuichi, N.; Terao, Y.; Wada, Y.; Tsuji, Y.

    2018-05-01

    This paper reports further experimental results obtained in high Reynolds number actual flow facility in Japan. The experiments were performed in a pipe flow with water, and the friction Reynolds number was varied up to Reτ = 5.3 × 104. This high Reynolds number was achieved by using water as the working fluid and adopting a large-diameter pipe (387 mm) while controlling the flow rate and temperature with high accuracy and precision. The streamwise velocity was measured by laser Doppler velocimetry close to the wall, and the mean velocity profile, called log-law profile U+ = (1/κ) ln(y+) + B, is especially focused. After careful verification of the mean velocity profiles in terms of the flow rate accuracy and an evaluation of the consistency of the present results with those from previously measurements in a smaller pipe (100 mm), it was found that the value of κ asymptotically approaches a constant value of κ = 0.384.

  20. Accuracy of Automatic Cephalometric Software on Landmark Identification

    Science.gov (United States)

    Anuwongnukroh, N.; Dechkunakorn, S.; Damrongsri, S.; Nilwarat, C.; Pudpong, N.; Radomsutthisarn, W.; Kangern, S.

    2017-11-01

    This study was to assess the accuracy of an automatic cephalometric analysis software in the identification of cephalometric landmarks. Thirty randomly selected digital lateral cephalograms of patients undergoing orthodontic treatment were used in this study. Thirteen landmarks (S, N, Or, A-point, U1T, U1A, B-point, Gn, Pog, Me, Go, L1T, and L1A) were identified on the digital image by an automatic cephalometric software and on cephalometric tracing by manual method. Superimposition of printed image and manual tracing was done by registration at the soft tissue profiles. The accuracy of landmarks located by the automatic method was compared with that of the manually identified landmarks by measuring the mean differences of distances of each landmark on the Cartesian plane where X and Y coordination axes passed through the center of ear rod. One-Sample T test was used to evaluate the mean differences. Statistically significant mean differences (pmean differences in both horizontal and vertical directions. Small mean differences (mean differences were found for A-point (3.0 4mm) in vertical direction. Only 5 of 13 landmarks (38.46%; S, N, Gn, Pog, and Go) showed no significant mean difference between the automatic and manual landmarking methods. It is concluded that if this automatic cephalometric analysis software is used for orthodontic diagnosis, the orthodontist must correct or modify the position of landmarks in order to increase the accuracy of cephalometric analysis.

  1. Discussions on the experimental data covering (EDC) procedure

    International Nuclear Information System (INIS)

    Lee, S.Y.; Ban, C.H.

    2004-01-01

    In describing step-9 of TRAC-CSAU, there is a statement that there is no clear guide with which one can determine the code uncertainty parameters and their statistics using the integral and/or separate effects tests. On the other hand, there is an important requirement, stating that the code uncertainty should be evaluated through direct data comparison with the relevant integral systems and separate-effects experiments at different scales. There are some efforts, in the best-estimate LOCA methodologies, to use the IET and SET data for determining the code uncertainty parameters and their statistics. But it is hard to find a systematic way to relate the code uncertainty parameters and/or their statistics with the results of the direct data comparison, especially in the case of the components with multiple code uncertainty parameters. It is essential to develop a procedure to implement the requirement of the direct data comparison with SETs and IETs in determining the code uncertainty. In this paper, Code Accuracy Based Uncertainty Estimation (CABUE) technique is introduced with an emphasis on the role of Experimental Data Coverings to connect the code accuracy with the overall uncertainty for a code prediction. Contrasting to the fact that the code accuracy is used only for confirmation of the conservatism in TRACCSAU, in CABUE, it can be represented by the scalable code parameters and their statistics through the EDC extensive calculations, it gives several benefits. Since the code accuracy becomes the measure of the determination of the statistics of code parameters, a code with better accuracy naturally provide smaller overall calculational uncertainty. This is the full implementation of the requirement of 'direct data comparison'. Adopting EDC procedure in CABUE where uniform application of distribution-free percentile estimation technique with simple random sampling calculations is used in various levels, makes it easy to chose the number of code uncertainty

  2. Additional measures do not improve the diagnostic accuracy of the Hospital Admission Risk Profile for detecting downstream quality of life in community-dwelling older people presenting to a hospital emergency department

    Directory of Open Access Journals (Sweden)

    Grimmer K

    2014-01-01

    Full Text Available K Grimmer, S Milanese, K Beaton, A AtlasInternational Centre for Allied Health Evidence, University of South Australia, Adelaide, SA, AustraliaIntroduction: The Hospital Admission Risk Profile (HARP instrument is commonly used to assess risk of functional decline when older people are admitted to hospital. HARP has moderate diagnostic accuracy (65% for downstream decreased scores in activities of daily living. This paper reports the diagnostic accuracy of HARP for downstream quality of life. It also tests whether adding other measures to HARP improves its diagnostic accuracy.Methods: One hundred and forty-eight independent community dwelling individuals aged 65 years or older were recruited in the emergency department of one large Australian hospital with a medical problem for which they were discharged without a hospital ward admission. Data, including age, sex, primary language, highest level of education, postcode, living status, requiring care for daily activities, using a gait aid, receiving formal community supports, instrumental activities of daily living in the last week, hospitalization and falls in the last 12 months, and mental state were collected at recruitment. HARP scores were derived from a formula that summed scores assigned to age, activities of daily living, and mental state categories. Physical and mental component scores of a quality of life measure were captured by telephone interview at 1 and 3 months after recruitment.Results: HARP scores are moderately accurate at predicting downstream decline in physical quality of life, but did not predict downstream decline in mental quality of life. The addition of other variables to HARP did not improve its diagnostic accuracy for either measure of quality of life.Conclusion: HARP is a poor predictor of quality of life.Keywords: functional decline, HARP, quality of life, older people

  3. Background of SAM atom-fraction profiles

    International Nuclear Information System (INIS)

    Ernst, Frank

    2017-01-01

    Atom-fraction profiles acquired by SAM (scanning Auger microprobe) have important applications, e.g. in the context of alloy surface engineering by infusion of carbon or nitrogen through the alloy surface. However, such profiles often exhibit an artifact in form of a background with a level that anti-correlates with the local atom fraction. This article presents a theory explaining this phenomenon as a consequence of the way in which random noise in the spectrum propagates into the discretized differentiated spectrum that is used for quantification. The resulting model of “energy channel statistics” leads to a useful semi-quantitative background reduction procedure, which is validated by applying it to simulated data. Subsequently, the procedure is applied to an example of experimental SAM data. The analysis leads to conclusions regarding optimum experimental acquisition conditions. The proposed method of background reduction is based on general principles and should be useful for a broad variety of applications. - Highlights: • Atom-fraction–depth profiles of carbon measured by scanning Auger microprobe • Strong background, varies with local carbon concentration. • Needs correction e.g. for quantitative comparison with simulations • Quantitative theory explains background. • Provides background removal strategy and practical advice for acquisition

  4. Background of SAM atom-fraction profiles

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, Frank

    2017-03-15

    Atom-fraction profiles acquired by SAM (scanning Auger microprobe) have important applications, e.g. in the context of alloy surface engineering by infusion of carbon or nitrogen through the alloy surface. However, such profiles often exhibit an artifact in form of a background with a level that anti-correlates with the local atom fraction. This article presents a theory explaining this phenomenon as a consequence of the way in which random noise in the spectrum propagates into the discretized differentiated spectrum that is used for quantification. The resulting model of “energy channel statistics” leads to a useful semi-quantitative background reduction procedure, which is validated by applying it to simulated data. Subsequently, the procedure is applied to an example of experimental SAM data. The analysis leads to conclusions regarding optimum experimental acquisition conditions. The proposed method of background reduction is based on general principles and should be useful for a broad variety of applications. - Highlights: • Atom-fraction–depth profiles of carbon measured by scanning Auger microprobe • Strong background, varies with local carbon concentration. • Needs correction e.g. for quantitative comparison with simulations • Quantitative theory explains background. • Provides background removal strategy and practical advice for acquisition.

  5. Subjective evaluation of the accuracy of video imaging prediction following orthognathic surgery in Chinese patients

    NARCIS (Netherlands)

    Chew, Ming Tak; Koh, Chay Hui; Sandham, John; Wong, Hwee Bee

    Purpose: The aims of this retrospective study were to assess the subjective accuracy of predictions generated by a computer imaging software in Chinese patients who had undergone orthognathic surgery and to determine the influence of initial dysgnathia and complexity of the surgical procedure on

  6. Determination of the ion thermal diffusivity from neutron emission profiles in decay

    Energy Technology Data Exchange (ETDEWEB)

    Sasao, M. (National Inst. for Fusion Science, Nagoya (Japan)); Adams, J.M. (AEA Industrial Technology, Harwell (United Kingdom)); Conroy, S.; Jarvis, O.N.; Marcus, F.B.; Sadler, G.; Belle, P. van (Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking)

    1994-01-01

    Spatial profiles of the neutron emission from deuterium plasmas are routinely obtained at the Joint European Torus (JET) using the line-integrated signals measured with a multichannel instrument. It is shown that the manner in which these profiles relax following the termination of strong heating with neutral beam injection (NBI) permits the local thermal diffusivity ([chi][sub i]) to be obtained with an accuracy of about 20%. (author).

  7. Evaluating the accuracy and effectiveness of criminal geographic profiling methods: The case of Dandora, Kenya

    NARCIS (Netherlands)

    Mburu, L; Helbich, M

    2015-01-01

    Criminal geographic profiling (CGP) prioritizes offender search, extensively reducing the resources expended in criminal investigations. The utility of CGP has, however, remained unclear when variations in environmental characteristics and offense type are introduced. This study evaluates several

  8. Analysis and Compensation for Gear Accuracy with Setting Error in Form Grinding

    Directory of Open Access Journals (Sweden)

    Chenggang Fang

    2015-01-01

    Full Text Available In the process of form grinding, gear setting error was the main factor that influenced the form grinding accuracy; we proposed an effective method to improve form grinding accuracy that corrected the error by controlling the machine operations. Based on establishing the geometry model of form grinding and representing the gear setting errors as homogeneous coordinate, tooth mathematic model was obtained and simplified under the gear setting error. Then, according to the gear standard of ISO1328-1: 1997 and the ANSI/AGMA 2015-1-A01: 2002, the relationship was investigated by changing the gear setting errors with respect to tooth profile deviation, helix deviation, and cumulative pitch deviation, respectively, under the condition of gear eccentricity error, gear inclination error, and gear resultant error. An error compensation method was proposed based on solving sensitivity coefficient matrix of setting error in a five-axis CNC form grinding machine; simulation and experimental results demonstrated that the method can effectively correct the gear setting error, as well as further improving the forming grinding accuracy.

  9. Communication: An adaptive configuration interaction approach for strongly correlated electrons with tunable accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Schriber, Jeffrey B.; Evangelista, Francesco A. [Department of Chemistry and Cherry L. Emerson Center for Scientific Computation, Emory University, Atlanta, Georgia 30322 (United States)

    2016-04-28

    We introduce a new procedure for iterative selection of determinant spaces capable of describing highly correlated systems. This adaptive configuration interaction (ACI) determines an optimal basis by an iterative procedure in which the determinant space is expanded and coarse grained until self-consistency. Two importance criteria control the selection process and tune the ACI to a user-defined level of accuracy. The ACI is shown to yield potential energy curves of N{sub 2} with nearly constant errors, and it predicts singlet-triplet splittings of acenes up to decacene that are in good agreement with the density matrix renormalization group.

  10. Analyzing thematic maps and mapping for accuracy

    Science.gov (United States)

    Rosenfield, G.H.

    1982-01-01

    Two problems which exist while attempting to test the accuracy of thematic maps and mapping are: (1) evaluating the accuracy of thematic content, and (2) evaluating the effects of the variables on thematic mapping. Statistical analysis techniques are applicable to both these problems and include techniques for sampling the data and determining their accuracy. In addition, techniques for hypothesis testing, or inferential statistics, are used when comparing the effects of variables. A comprehensive and valid accuracy test of a classification project, such as thematic mapping from remotely sensed data, includes the following components of statistical analysis: (1) sample design, including the sample distribution, sample size, size of the sample unit, and sampling procedure; and (2) accuracy estimation, including estimation of the variance and confidence limits. Careful consideration must be given to the minimum sample size necessary to validate the accuracy of a given. classification category. The results of an accuracy test are presented in a contingency table sometimes called a classification error matrix. Usually the rows represent the interpretation, and the columns represent the verification. The diagonal elements represent the correct classifications. The remaining elements of the rows represent errors by commission, and the remaining elements of the columns represent the errors of omission. For tests of hypothesis that compare variables, the general practice has been to use only the diagonal elements from several related classification error matrices. These data are arranged in the form of another contingency table. The columns of the table represent the different variables being compared, such as different scales of mapping. The rows represent the blocking characteristics, such as the various categories of classification. The values in the cells of the tables might be the counts of correct classification or the binomial proportions of these counts divided by

  11. Fractal Analysis of Rock Joint Profiles

    Science.gov (United States)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    Surface reliefs of rock joints are analyzed in geotechnics when shear strength of rocky slopes is estimated. The rock joint profiles actually are self-affine fractal curves and computations of their fractal dimensions require special methods. Many papers devoted to the fractal properties of these profiles were published in the past but only a few of those papers employed a convenient computational method that would have guaranteed a sound value of that dimension. As a consequence, anomalously low dimensions were presented. This contribution deals with two computational modifications that lead to sound fractal dimensions of the self-affine rock joint profiles. These are the modified box-counting method and the modified yard-stick method sometimes called the compass method. Both these methods are frequently applied to self-similar fractal curves but the self-affine profile curves due to their self-affine nature require modified computational procedures implemented in computer programs.

  12. New non-cognitive procedures for medical applicant selection: a qualitative analysis in one school.

    Science.gov (United States)

    Katz, Sara; Vinker, Shlomo

    2014-11-07

    Recent data have called into question the reliability and predictive validity of standard admission procedures to medical schools. Eliciting non-cognitive attributes of medical school applicants using qualitative tools and methods has thus become a major challenge. 299 applicants aged 18-25 formed the research group. A set of six research tools was developed in addition to the two existing ones. These included: a portfolio task, an intuitive task, a cognitive task, a personal task, an open self-efficacy questionnaire and field-notes. The criteria-based methodology design used constant comparative analysis and grounded theory techniques to produce a personal attributes profile per participant, scored on a 5-point scale holistic rubric. Qualitative validity of data gathering was checked by comparing the profiles elicited from the existing interview against the profiles elicited from the other tools, and by comparing two profiles of each of the applicants who handed in two portfolio tasks. Qualitative validity of data analysis was checked by comparing researcher results with those of an external rater (n =10). Differences between aggregated profile groups were checked by the Npar Wilcoxon Signed Ranks Test and by Spearman Rank Order Correlation Test. All subjects gave written informed consent to their participation. Privacy was protected by using code numbers. A concept map of 12 personal attributes emerged, the core constructs of which were motivation, sociability and cognition. A personal profile was elicited. Inter-rater agreement was 83.3%. Differences between groups by aggregated profiles were found significant (p < .05, p < .01, p < .001).A random sample of sixth year students (n = 12) underwent the same admission procedure as the research group. Rank order was different; and arrogance was a new construct elicited in the sixth year group. This study suggests a broadening of the methodology for selecting medical school applicants. This methodology

  13. Middle-Ear Microsurgery Simulation to Improve New Robotic Procedures

    Directory of Open Access Journals (Sweden)

    Guillaume Kazmitcheff

    2014-01-01

    Full Text Available Otological microsurgery is delicate and requires high dexterity in bad ergonomic conditions. To assist surgeons in these indications, a teleoperated system, called RobOtol, is developed. This robot enhances gesture accuracy and handiness and allows exploration of new procedures for middle ear surgery. To plan new procedures that exploit the capacities given by the robot, a surgical simulator is developed. The simulation reproduces with high fidelity the behavior of the anatomical structures and can also be used as a training tool for an easier control of the robot for surgeons. In the paper, we introduce the middle ear surgical simulation and then we perform virtually two challenging procedures with the robot. We show how interactive simulation can assist in analyzing the benefits of robotics in the case of complex manipulations or ergonomics studies and allow the development of innovative surgical procedures. New robot-based microsurgical procedures are investigated. The improvement offered by RobOtol is also evaluated and discussed.

  14. Reduced infant response to a routine care procedure after sucrose analgesia.

    Science.gov (United States)

    Taddio, Anna; Shah, Vibhuti; Katz, Joel

    2009-03-01

    Sucrose has analgesic and calming effects in newborns. To date, it is not known whether the beneficial effects extend to caregiving procedures that are performed after painful procedures. Our objective was to determine the effect of sucrose analgesia for procedural pain on infant pain responses during a subsequent caregiving procedure. We conducted a double-blind, randomized, controlled trial. Healthy neonates within 2 strata (normal infants and infants of diabetic mothers) were randomly assigned to a sucrose or placebo water group before all needle procedures after birth. Pain response during a diaper change performed after venipuncture for the newborn screening test was determined by using a validated multidimensional measure, the Premature Infant Pain Profile. The study was conducted between September 15, 2003, and July 27, 2004. Altogether, 412 parents were approached; 263 consented. Twenty-three infants were not assigned, leaving 240 for participation (n = 120 per group), with an equal number in each infant strata. Of those, 186 (78%) completed the study. There were no significant differences in birth characteristics between groups. During diaper change, sucrose-treated infants had lower pain scores than placebo-treated infants. The relative risk of having pain, defined as a Premature Infant Pain Profile score of >/=6, was 0.64 with sucrose compared with placebo. This study demonstrates that when used to manage pain, sucrose reduces the pain response to a subsequent routine caregiving procedure. Therefore, the benefits of sucrose analgesia extend beyond the painful event to other aversive and potentially painful procedures.

  15. New Procedure to Develop Lumped Kinetic Models for Heavy Fuel Oil Combustion

    KAUST Repository

    Han, Yunqing

    2016-09-20

    A new procedure to develop accurate lumped kinetic models for complex fuels is proposed, and applied to the experimental data of the heavy fuel oil measured by thermogravimetry. The new procedure is based on the pseudocomponents representing different reaction stages, which are determined by a systematic optimization process to ensure that the separation of different reaction stages with highest accuracy. The procedure is implemented and the model prediction was compared against that from a conventional method, yielding a significantly improved agreement with the experimental data. © 2016 American Chemical Society.

  16. The prediction of BRDFs from surface profile measurements

    International Nuclear Information System (INIS)

    Church, E.L.; Takacs, P.Z.; Leonard, T.A.

    1989-01-01

    This paper discusses methods of predicting the BRDF of smooth surfaces from profile measurements of their surface finish. The conversion of optical profile data to the BRDF at the same wavelength is essentially independent of scattering models, while the conversion of mechanical measurements, and wavelength scaling in general, are model dependent. Procedures are illustrated for several surfaces, including two from the recent HeNe BRDF round robin, and results are compared with measured data. Reasonable agreement is found except for surfaces which involve significant scattering from isolated surface defects which are poorly sampled in the profile data

  17. An automated, noncontact laser profile meter for measuring soil roughness in situ

    International Nuclear Information System (INIS)

    Bertuzzi, P.; Caussignac, J.M.; Stengel, P.; Morel, G.; Lorendeau, J.Y.; Pelloux, G.

    1990-01-01

    This paper describes a new optical technique for measuring in situ soil surface roughness profiles using a laser profile meter. The described method uses a low-power HeNe (helium-neon) laser as a laser source and a matrix-array detector, as the laser image. The matrix-array detector gives a defect-of-focus laser image of the soil. Soil elevation is measured by projecting a laser beam normally onto the soil surface and measuring the ratio (Ir/It) on the matrix-array detector between the referenced intensity of the return Laser beam (Ir), measured by the central cell of the detector and the total intensity (It), measured by all the cells of the detector. The measured profile leads to 1001 sampled values (volt, range 0 to 10 V) of the surface height profile, at a constant increment of 0.002 m, registered automatically on a microcomputer. A calibration is made in the laboratory in order to convert the electrical measurements into elevation data. The method is universal and can be adapted to different scales of soil surface roughness. Changing the scale is done by changing the lens. Tests were carried out to improve this method for field use and to compare this technique with a method of reference. This technique is considerably quicker and causes no disturbance to the soil. The accuracy on height measurement depends on the choice of the lens. The small focal lens is convenient for smooth soil surfaces. The accuracy on height measurement is less than 0.75 mm. The wide focal lens is convenient for rough soil surfaces. The accuracy on height measurement is estimated at about 1.0 to 1.5 mm

  18. Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

    Science.gov (United States)

    Kamble, Suresh S; Khandeparker, Rakshit Vijay; Somasundaram, P; Raghav, Shweta; Babaji, Rashmi P; Varghese, T Joju

    2015-09-01

    Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method. The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures. Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes. The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.

  19. Variation in Microbial Identification System accuracy for yeast identification depending on commercial source of Sabouraud dextrose agar.

    Science.gov (United States)

    Kellogg, J A; Bankert, D A; Chaturvedi, V

    1999-06-01

    The accuracy of the Microbial Identification System (MIS; MIDI, Inc. ) for identification of yeasts to the species level was compared by using 438 isolates grown on prepoured BBL Sabouraud dextrose agar (SDA) and prepoured Remel SDA. Correct identification was observed for 326 (74%) of the yeasts cultured on BBL SDA versus only 214 (49%) of yeasts grown on Remel SDA (P < 0.001). The commercial source of the SDA used in the MIS procedure significantly influences the system's accuracy.

  20. Safety and diagnostic accuracy of dipyridamole-thallium imaging in the elderly

    International Nuclear Information System (INIS)

    Lam, J.Y.; Chaitman, B.R.; Glaenzer, M.; Byers, S.; Fite, J.; Shah, Y.; Goodgold, H.; Samuels, L.

    1988-01-01

    The noninvasive diagnosis of coronary artery disease in the elderly can occasionally be difficult. Intravenous dipyridamole-thallium imaging is a potentially useful diagnostic test to determine presence and severity of coronary disease; however, the safety of the procedure has not been determined in an older population. The side effect profile and frequency of severe ischemic responses after 0.56 mg/kg of intravenous dipyridamole were compared in 101 patients greater than or equal to 70 years old and 236 patients less than 70 years old. There were no side effects in 64% and 62% of patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). Among the 337 patients tested, there were no complications of myocardial infarction or death. The most common cardiac side effect was chest pain, which occurred in 21 (21%) of the 101 patients aged greater than or equal to 70 years and in 64 (27%) of the 236 patients less than 70 years (p = NS). Aminophylline was required to reverse cardiac or noncardiac side effects in 15 (15%) and 36 (15%) of the patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). A severe ischemic response occurred in 2% and 2.5% of patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). The sensitivity of intravenous dipyridamole-thallium imaging for obstructive coronary artery disease was 86% (25 of 29) and 83% (68 of 82) in older and younger patients, respectively (p = NS); the specificity was 75% (6 of 8) and 70% (16 of 23), respectively (p = NS). Thus, intravenous dipyridamole-thallium imaging is a safe noninvasive method for assessment of older patients with obstructive coronary disease; its side effect profile and diagnostic accuracy are similar to those seen in younger patients. The technique is associated with severe ischemic responses in only a small minority of patients

  1. Elderly fall risk prediction based on a physiological profile approach using artificial neural networks.

    Science.gov (United States)

    Razmara, Jafar; Zaboli, Mohammad Hassan; Hassankhani, Hadi

    2016-11-01

    Falls play a critical role in older people's life as it is an important source of morbidity and mortality in elders. In this article, elders fall risk is predicted based on a physiological profile approach using a multilayer neural network with back-propagation learning algorithm. The personal physiological profile of 200 elders was collected through a questionnaire and used as the experimental data for learning and testing the neural network. The profile contains a series of simple factors putting elders at risk for falls such as vision abilities, muscle forces, and some other daily activities and grouped into two sets: psychological factors and public factors. The experimental data were investigated to select factors with high impact using principal component analysis. The experimental results show an accuracy of ≈90 percent and ≈87.5 percent for fall prediction among the psychological and public factors, respectively. Furthermore, combining these two datasets yield an accuracy of ≈91 percent that is better than the accuracy of single datasets. The proposed method suggests a set of valid and reliable measurements that can be employed in a range of health care systems and physical therapy to distinguish people who are at risk for falls.

  2. Accuracy Assessment of Underwater Photogrammetric Three Dimensional Modelling for Coral Reefs

    Science.gov (United States)

    Guo, T.; Capra, A.; Troyer, M.; Gruen, A.; Brooks, A. J.; Hench, J. L.; Schmitt, R. J.; Holbrook, S. J.; Dubbini, M.

    2016-06-01

    Recent advances in automation of photogrammetric 3D modelling software packages have stimulated interest in reconstructing highly accurate 3D object geometry in unconventional environments such as underwater utilizing simple and low-cost camera systems. The accuracy of underwater 3D modelling is affected by more parameters than in single media cases. This study is part of a larger project on 3D measurements of temporal change of coral cover in tropical waters. It compares the accuracies of 3D point clouds generated by using images acquired from a system camera mounted in an underwater housing and the popular GoPro cameras respectively. A precisely measured calibration frame was placed in the target scene in order to provide accurate control information and also quantify the errors of the modelling procedure. In addition, several objects (cinder blocks) with various shapes were arranged in the air and underwater and 3D point clouds were generated by automated image matching. These were further used to examine the relative accuracy of the point cloud generation by comparing the point clouds of the individual objects with the objects measured by the system camera in air (the best possible values). Given a working distance of about 1.5 m, the GoPro camera can achieve a relative accuracy of 1.3 mm in air and 2.0 mm in water. The system camera achieved an accuracy of 1.8 mm in water, which meets our requirements for coral measurement in this system.

  3. Improve accuracy and sensibility in glycan structure prediction by matching glycan isotope abundance

    International Nuclear Information System (INIS)

    Xu Guang; Liu Xin; Liu Qingyan; Zhou Yanhong; Li Jianjun

    2012-01-01

    Highlights: ► A glycan isotope pattern recognition strategy for glycomics. ► A new data preprocessing procedure to detect ion peaks in a giving MS spectrum. ► A linear soft margin SVM classification for isotope pattern recognition. - Abstract: Mass Spectrometry (MS) is a powerful technique for the determination of glycan structures and is capable of providing qualitative and quantitative information. Recent development in computational method offers an opportunity to use glycan structure databases and de novo algorithms for extracting valuable information from MS or MS/MS data. However, detecting low-intensity peaks that are buried in noisy data sets is still a challenge and an algorithm for accurate prediction and annotation of glycan structures from MS data is highly desirable. The present study describes a novel algorithm for glycan structure prediction by matching glycan isotope abundance (mGIA), which takes isotope masses, abundances, and spacing into account. We constructed a comprehensive database containing 808 glycan compositions and their corresponding isotope abundance. Unlike most previously reported methods, not only did we take into count the m/z values of the peaks but also their corresponding logarithmic Euclidean distance of the calculated and detected isotope vectors. Evaluation against a linear classifier, obtained by training mGIA algorithm with datasets of three different human tissue samples from Consortium for Functional Glycomics (CFG) in association with Support Vector Machine (SVM), was proposed to improve the accuracy of automatic glycan structure annotation. In addition, an effective data preprocessing procedure, including baseline subtraction, smoothing, peak centroiding and composition matching for extracting correct isotope profiles from MS data was incorporated. The algorithm was validated by analyzing the mouse kidney MS data from CFG, resulting in the identification of 6 more glycan compositions than the previous annotation

  4. Magnetoencephalographic accuracy profiles for the detection of auditory pathway sources.

    Science.gov (United States)

    Bauer, Martin; Trahms, Lutz; Sander, Tilmann

    2015-04-01

    The detection limits for cortical and brain stem sources associated with the auditory pathway are examined in order to analyse brain responses at the limits of the audible frequency range. The results obtained from this study are also relevant to other issues of auditory brain research. A complementary approach consisting of recordings of magnetoencephalographic (MEG) data and simulations of magnetic field distributions is presented in this work. A biomagnetic phantom consisting of a spherical volume filled with a saline solution and four current dipoles is built. The magnetic fields outside of the phantom generated by the current dipoles are then measured for a range of applied electric dipole moments with a planar multichannel SQUID magnetometer device and a helmet MEG gradiometer device. The inclusion of a magnetometer system is expected to be more sensitive to brain stem sources compared with a gradiometer system. The same electrical and geometrical configuration is simulated in a forward calculation. From both the measured and the simulated data, the dipole positions are estimated using an inverse calculation. Results are obtained for the reconstruction accuracy as a function of applied electric dipole moment and depth of the current dipole. We found that both systems can localize cortical and subcortical sources at physiological dipole strength even for brain stem sources. Further, we found that a planar magnetometer system is more suitable if the position of the brain source can be restricted in a limited region of the brain. If this is not the case, a helmet-shaped sensor system offers more accurate source estimation.

  5. Reproducibility of Automated Voice Range Profiles, a Systematic Literature Review

    DEFF Research Database (Denmark)

    Printz, Trine; Rosenberg, Tine; Godballe, Christian

    2018-01-01

    literature on test-retest accuracy of the automated voice range profile assessment. Study design: Systematic review. Data sources: PubMed, Scopus, Cochrane Library, ComDisDome, Embase, and CINAHL (EBSCO). Methods: We conducted a systematic literature search of six databases from 1983 to 2016. The following...

  6. Extended device profiles and testing procedures for the approval process of integrated medical devices using the IEEE 11073 communication standard.

    Science.gov (United States)

    Janß, Armin; Thorn, Johannes; Schmitz, Malte; Mildner, Alexander; Dell'Anna-Pudlik, Jasmin; Leucker, Martin; Radermacher, Klaus

    2018-02-23

    Nowadays, only closed and proprietary integrated operating room systems (IORS) from big manufacturers are available on the market. Hence, the interconnection of components from third-party vendors is only possible with increased time and costs. In the context of the German Federal Ministry of Education and Research (BMBF)-funded project OR.NET (2012-2016), the open integration of medical devices from different manufacturers was addressed. An integrated operating theater based on the open communication standard IEEE 11073 shall give clinical operators the opportunity to choose medical devices independently of the manufacturer. This approach would be advantageous especially for hospital operators and small- and medium-sized enterprises (SME) of medical devices. Actual standards and concepts regarding technical feasibility and the approval process do not cope with the requirements for a modular integration of medical devices in the operating room (OR), based on an open communication standard. Therefore, innovative approval strategies and corresponding certification and test procedures, which cover actual legal and normative standards, have to be developed in order to support the future risk management and the usability engineering process of open integrated medical devices in the OR. The use of standardized device and service profiles and a three-step testing procedure, including conformity, interoperability and integration tests are described in this paper and shall support the manufacturers to integrate their medical devices without disclosing the medical devices' risk analysis and related confidential expertise or proprietary information.

  7. Implementation of reflectometry as a standard density profile diagnostic on DIII-D

    International Nuclear Information System (INIS)

    Zeng, L.; Doyle, E. J.; Luce, T. C.; Peebles, W. A.

    2001-01-01

    The profile reflectometer system on the DIII-D tokamak has been significantly upgraded in order to improve time coverage, data quality, and profile availability. The performance of the reflectometer system, which utilizes continuous frequency modulated (FMCW) radar techniques, has been improved as follows: First, a new PC-based data acquisition system has been installed, providing higher data sampling rates and larger memory depth. The higher sampling rate enables use of faster frequency sweeps of the FMCW microwave source, improving time resolution, and increasing profile accuracy. The larger memory depth enables longer data records, so that profiles can now be obtained throughout 5 s discharges at 100 Hz profile measurement rates, while continuous sampling at 10 MHz is available for 1 s for high time resolution physics studies. Second, an initial automated between-shots profile analysis capability is now available. Third, availability of the profiles to end users has been significantly improved

  8. Empirical testing of forecast update procedure forseasonal products

    DEFF Research Database (Denmark)

    Wong, Chee Yew; Johansen, John

    2008-01-01

    Updating of forecasts is essential for successful collaborative forecasting, especially for seasonal products. This paper discusses the results of a theoretical simulation and an empirical test of a proposed time-series forecast updating procedure. It involves a two-stage longitudinal case study...... of a toy supply chain. The theoretical simulation involves historical weekly consumer demand data for 122 toy products. The empirical test is then carried out in real-time with 291 toy products. The results show that the proposed forecast updating procedure: 1) reduced forecast errors of the annual...... provided less forecast accuracy improvement and it needed a longer time to achieve relatively acceptable forecast uncertainty....

  9. Assessing the accuracy and stability of variable selection methods for random forest modeling in ecology.

    Science.gov (United States)

    Fox, Eric W; Hill, Ryan A; Leibowitz, Scott G; Olsen, Anthony R; Thornbrugh, Darren J; Weber, Marc H

    2017-07-01

    Random forest (RF) modeling has emerged as an important statistical learning method in ecology due to its exceptional predictive performance. However, for large and complex ecological data sets, there is limited guidance on variable selection methods for RF modeling. Typically, either a preselected set of predictor variables are used or stepwise procedures are employed which iteratively remove variables according to their importance measures. This paper investigates the application of variable selection methods to RF models for predicting probable biological stream condition. Our motivating data set consists of the good/poor condition of n = 1365 stream survey sites from the 2008/2009 National Rivers and Stream Assessment, and a large set (p = 212) of landscape features from the StreamCat data set as potential predictors. We compare two types of RF models: a full variable set model with all 212 predictors and a reduced variable set model selected using a backward elimination approach. We assess model accuracy using RF's internal out-of-bag estimate, and a cross-validation procedure with validation folds external to the variable selection process. We also assess the stability of the spatial predictions generated by the RF models to changes in the number of predictors and argue that model selection needs to consider both accuracy and stability. The results suggest that RF modeling is robust to the inclusion of many variables of moderate to low importance. We found no substantial improvement in cross-validated accuracy as a result of variable reduction. Moreover, the backward elimination procedure tended to select too few variables and exhibited numerous issues such as upwardly biased out-of-bag accuracy estimates and instabilities in the spatial predictions. We use simulations to further support and generalize results from the analysis of real data. A main purpose of this work is to elucidate issues of model selection bias and instability to ecologists interested in

  10. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  11. International comparison of interpolation procedures for the efficiency of germanium gamma-ray spectrometers (GAM83 exercise)

    International Nuclear Information System (INIS)

    Zijp, W.L.; Polle, A.N.; Nolthenius, H.J.

    1986-01-01

    Results are presented for the outcome of an international intercomparison of a particular gamma-ray spectrometric procedure. Laboratories were asked to determine full energy peak efficiencies and activities by means of their own procedures, starting from supplied peak-efficiency data. Four data sets for four different conditions of germanium detectors were distributed. The sets comprised: a high accuracy- (uncertainty > 1%) data set with a relatively large number of measured data (SET 1); a low accuracy- (uncertainty 3-5%) data set with a relatively small number of measured data (SET 2); a low energy-data set (SET 3); a high accuracy-data set with a relatively small number of measured data (SET 4). The intercomparison (coded GAM83) was organized and analyzed under auspices of the International Committee for Radionuclide Metrology (ICRM). The results comprise the analysis of the contributions of 41 participants

  12. Profile analysis of neutron powder diffraction data at ISIS

    International Nuclear Information System (INIS)

    David, W.I.F.; Ibberson, R.M.; Matthewman, J.C.

    1992-05-01

    The aim of this manual is to document the current suite of time-of-flight neutron powder diffraction profile refinement programs available to ISIS users. Aspects of data collation and normalisation specific to the individual diffraction instruments are dealt with elsewhere. It will be assumed the user has produced a suitable data file (.DAT file) containing the profile data consisting of point by point values of the corrected diffraction profile across the pattern. The analysis of neutron powder diffraction data at ISIS by profile refinement utilises a suite of ''in-house'' written and supported programs based on the Cambridge Crystallography Subroutine Library (CCSL). A quick scan through the CCSL manual will give the user a general feel for the procedure to adopt in the use of the library and hence of the profile codes. The instructions documented in this handbook are complementary to those in the more specialist CCSL manual, and consequently go into no great detail regarding technical details of any of the CCSL routines. The programs may be run from each individual user account, for example [USER01], once the appropriate login procedure has been set-up by the instrument scientists. The programs are mostly activated by one line commands and only a basic knowledge of a VAX editor should be required; details can be found in the ''VAX primer'' available from Computer Support. (Author)

  13. The demographic, clinical and forensic profile of offenders ...

    African Journals Online (AJOL)

    The demographic, clinical and forensic profile of offenders diagnosed with epilepsy referred to the Free State Psychiatric Complex Observation Unit in terms of section 77 and/or 78 of the Criminal Procedure Act 51 of 1977.

  14. Geometric accuracy of field alignment in fractionated stereotactic conformal radiotherapy of brain tumors

    International Nuclear Information System (INIS)

    Kortmann, Rolf D.; Becker, Gerd; Perelmouter, Jury; Buchgeister, Markus; Meisner, Christoph; Bamberg, Michael

    1999-01-01

    Purpose: To assess the accuracy of field alignment in patients undergoing three-dimensional (3D) conformal radiotherapy of brain tumors, and to evaluate the impact on the definition of planning target volume and control procedures. Methods and Materials: Geometric accuracy was analyzed in 20 patients undergoing fractionated stereotactic conformal radiotherapy for brain tumors. Rigid head fixation was achieved by using cast material. Transfer of stereotactic coordinates was performed by an external positioning device. The accuracy during treatment planning was quantitatively assessed by using repeated computed tomography (CT) examinations in treatment position (reproducibility of isocenter). Linear discrepancies were measured between treatment plan and CT examination. In addition, for each patient, a series of 20 verifications were taken in orthogonal projections. Linear discrepancies were measured between first and all subsequent verifications (accuracy during treatment delivery). Results: For the total group of patients, the distribution of deviations during treatment setup showed mean values between -0.3-1.2 mm, with standard deviations (SD) of 1.3-2.0 mm. During treatment delivery, the distribution of deviations revealed mean values between 0.7-0.8 mm, with SDs of 0.5-0.6 mm, respectively. For all patients, deviations for the transition to the treatment machine were similar to deviations during subsequent treatment delivery, with 95% of all absolute deviations between less than 2.8 and 4.6 mm. Conclusion: Random fluctuations of field displacements during treatment planning and delivery prevail. Therefore, our quantitative data should be considered when prescribing the safety margins of the planning target volume. Repeated CT examination are useful to detect operator errors and large random or systematic deviations before start of treatment. Control procedures during treatment delivery appear to be of limited importance. In addition, our findings should help to

  15. Bootstrap-based procedures for inference in nonparametric receiver-operating characteristic curve regression analysis.

    Science.gov (United States)

    Rodríguez-Álvarez, María Xosé; Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Tahoces, Pablo G

    2018-03-01

    Prior to using a diagnostic test in a routine clinical setting, the rigorous evaluation of its diagnostic accuracy is essential. The receiver-operating characteristic curve is the measure of accuracy most widely used for continuous diagnostic tests. However, the possible impact of extra information about the patient (or even the environment) on diagnostic accuracy also needs to be assessed. In this paper, we focus on an estimator for the covariate-specific receiver-operating characteristic curve based on direct regression modelling and nonparametric smoothing techniques. This approach defines the class of generalised additive models for the receiver-operating characteristic curve. The main aim of the paper is to offer new inferential procedures for testing the effect of covariates on the conditional receiver-operating characteristic curve within the above-mentioned class. Specifically, two different bootstrap-based tests are suggested to check (a) the possible effect of continuous covariates on the receiver-operating characteristic curve and (b) the presence of factor-by-curve interaction terms. The validity of the proposed bootstrap-based procedures is supported by simulations. To facilitate the application of these new procedures in practice, an R-package, known as npROCRegression, is provided and briefly described. Finally, data derived from a computer-aided diagnostic system for the automatic detection of tumour masses in breast cancer is analysed.

  16. Liver Gene Expression Profiles of Rats Treated with Clofibric Acid

    Science.gov (United States)

    Michel, Cécile; Desdouets, Chantal; Sacre-Salem, Béatrice; Gautier, Jean-Charles; Roberts, Ruth; Boitier, Eric

    2003-01-01

    Clofibric acid (CLO) is a peroxisome proliferator (PP) that acts through the peroxisome proliferator activated receptor α, leading to hepatocarcinogenesis in rodents. CLO-induced hepatocarcinogenesis is a multi-step process, first transforming normal liver cells into foci. The combination of laser capture microdissection (LCM) and genomics has the potential to provide expression profiles from such small cell clusters, giving an opportunity to understand the process of cancer development in response to PPs. To our knowledge, this is the first evaluation of the impact of the successive steps of LCM procedure on gene expression profiling by comparing profiles from LCM samples to those obtained with non-microdissected liver samples collected after a 1 month CLO treatment in the rat. We showed that hematoxylin and eosin (H&E) staining and laser microdissection itself do not impact on RNA quality. However, the overall process of the LCM procedure affects the RNA quality, resulting in a bias in the gene profiles. Nonetheless, this bias did not prevent accurate determination of a CLO-specific molecular signature. Thus, gene-profiling analysis of microdissected foci, identified by H&E staining may provide insight into the mechanisms underlying non-genotoxic hepatocarcinogenesis in the rat by allowing identification of specific genes that are regulated by CLO in early pre-neoplastic foci. PMID:14633594

  17. Post-Mission Quality Assurance Procedure for Survey-Grade Mobile Mapping Systems

    Science.gov (United States)

    Kerstinga, A. P.; Friess, P.

    2016-06-01

    Mobile Mapping Systems (MMS) consist of terrestrial-based moving platforms that integrate a set of imaging sensors (typically digital cameras and laser scanners) and a Position and Orientation System (POS), designed to collect data of the surrounding environment. MMS can be classified as "mapping-grade" or "survey-grade" depending on the system's attainable accuracy. Mapping-grade MMS produce geospatial data suitable for GIS applications (e.g., asset management) while survey-grade systems should satisfy high-accuracy applications such as engineering/design projects. The delivered accuracy of an MMS is dependent on several factors such as the accuracy of the system measurements and calibration parameters. It is critical, especially for survey-grade systems, to implement a robust Quality Assurance (QA) procedure to ensure the achievement of the expected accuracy. In this paper, a new post-mission QA procedure is presented. The presented method consists of a fully-automated self-calibration process that allows for the estimation of corrections to the system calibration parameters (e.g., boresight angles and lever-arm offsets relating the lidar sensor(s) to the IMU body frame) as well as corrections to the system measurements (e.g., post-processed trajectory position and orientation, scan angles and ranges). As for the system measurements, the major challenge for MMS is related to the trajectory determination in the presence of multipath signals and GNSS outages caused by buildings, underpasses and high vegetation. In the proposed self-calibration method, trajectory position errors are properly modelled while utilizing an efficient/meaningful trajectory segmentation technique. The validity of the proposed method is demonstrated using a dataset collected under unfavorable GNSS conditions.

  18. POST-MISSION QUALITY ASSURANCE PROCEDURE FOR SURVEY-GRADE MOBILE MAPPING SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. P. Kerstinga

    2016-06-01

    Full Text Available Mobile Mapping Systems (MMS consist of terrestrial-based moving platforms that integrate a set of imaging sensors (typically digital cameras and laser scanners and a Position and Orientation System (POS, designed to collect data of the surrounding environment. MMS can be classified as “mapping-grade” or “survey-grade” depending on the system’s attainable accuracy. Mapping-grade MMS produce geospatial data suitable for GIS applications (e.g., asset management while survey-grade systems should satisfy high-accuracy applications such as engineering/design projects. The delivered accuracy of an MMS is dependent on several factors such as the accuracy of the system measurements and calibration parameters. It is critical, especially for survey-grade systems, to implement a robust Quality Assurance (QA procedure to ensure the achievement of the expected accuracy. In this paper, a new post-mission QA procedure is presented. The presented method consists of a fully-automated self-calibration process that allows for the estimation of corrections to the system calibration parameters (e.g., boresight angles and lever-arm offsets relating the lidar sensor(s to the IMU body frame as well as corrections to the system measurements (e.g., post-processed trajectory position and orientation, scan angles and ranges. As for the system measurements, the major challenge for MMS is related to the trajectory determination in the presence of multipath signals and GNSS outages caused by buildings, underpasses and high vegetation. In the proposed self-calibration method, trajectory position errors are properly modelled while utilizing an efficient/meaningful trajectory segmentation technique. The validity of the proposed method is demonstrated using a dataset collected under unfavorable GNSS conditions.

  19. Operational Test Report for the 241-AZ-101 Suspended Solids Profiler

    International Nuclear Information System (INIS)

    STENKAMP, D.M.

    2000-01-01

    This document comprises the Operational Test Report for the 241-AZ-101 Suspended Solids Profiler. This document presents the results of Operational Testing of the 241-AZ-101 Suspended Solids Profiler (SSP). Testing of the SSP was performed in accordance with OTP-260-005, ''SUSPENDED SOLIDS PROFILER OPERATIONAL TEST PROCEDURE''. The objective of the testing was to verify that all equipment and components functioned as designed, following construction completion and turnover to operations

  20. Lagoa Real design. Cachoeira mine. Uranium ratio from gamma profile

    International Nuclear Information System (INIS)

    Juliao, B.

    1984-06-01

    This paper presents the satisfactory accuracy of uranium ratio from gamma profile, using an equation from simple regression. The comparative study between radiometric ratios calculated from gamma data in boreholes and uranium ratio determined by Delayed Neutron Analysis shows a good measure of correlation in Cachoeira Mines. (author)

  1. Variation in Microbial Identification System Accuracy for Yeast Identification Depending on Commercial Source of Sabouraud Dextrose Agar

    OpenAIRE

    Kellogg, James A.; Bankert, David A.; Chaturvedi, Vishnu

    1999-01-01

    The accuracy of the Microbial Identification System (MIS; MIDI, Inc.) for identification of yeasts to the species level was compared by using 438 isolates grown on prepoured BBL Sabouraud dextrose agar (SDA) and prepoured Remel SDA. Correct identification was observed for 326 (74%) of the yeasts cultured on BBL SDA versus only 214 (49%) of yeasts grown on Remel SDA (P < 0.001). The commercial source of the SDA used in the MIS procedure significantly influences the system’s accuracy.

  2. C-arm cone-beam CT virtual navigation-guided percutaneous mediastinal mass biopsy: Diagnostic accuracy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungjin [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Aerospace Medical Group, Air Force Education and Training Command, Jinju (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2015-12-15

    To assess the usefulness of C-arm cone-beam computed tomography (CBCT) virtual navigation-guided percutaneous mediastinal mass biopsy in terms of diagnostic accuracy and complication rates. Seventy-eight CBCT virtual navigation-guided percutaneous mediastinal mass biopsies were performed in 75 patients (M:F, 38:37; mean age, 48.55 ± 18.76 years). The procedural details, diagnostic sensitivity, specificity, accuracy and complication rate were investigated. Mean lesion size was 6.80 ± 3.08 cm, skin-to-target distance was 3.67 ± 1.80 cm, core needle biopsy rate was 96.2 % (75/78), needle indwelling time was 9.29 ± 4.34 min, total procedure time was 13.26 ± 5.29 min, number of biopsy specimens obtained was 3.13 ± 1.02, number of CBCTs performed was 3.03 ± 0.68, rate of lesion border discrimination from abutting mediastinal structures on CBCT was 26.9 % (21/78), technical success rate was 100 % (78/78), estimated effective dose was 5.33 ± 4.99 mSv, and the dose area product was 12,723.68 ± 10,665.74 mGy.cm{sup 2}. Among the 78 biopsies, 69 were malignant, 7 were benign and 2 were indeterminate. Diagnostic sensitivity, specificity and accuracy for the diagnosis of malignancies were 97.1 % (67/69), 100 % (7/7) and 97.4 % (74/76), respectively, with a complication rate of 3.85 % (3/78), all of which were small pneumothoraces. CBCT virtual navigation-guided biopsy is a highly accurate and safe procedure for the evaluation of mediastinal lesions. (orig.)

  3. Beam profile monitors for a tagged photon beam facility

    International Nuclear Information System (INIS)

    Arends, J.; Breuer, M.; Dahmen, H.D.; Detemple, P.; Schneider, W.; Urban, D.; Zucht, B.

    1991-01-01

    A beam profile monitor for electron and photon beams is described, which operates at the low intensities encountered in a tagged bremsstrahlung beam environment, typically 10 10 electrons/s and 10 7 photons/s. The method is based on a wire scanner and utilizes the presence of a tagging spectrometer. The accuracy of the measurements can be tuned in a wide range to meet the requirements set by the actual beam parameters. Examples of measured electron and photon beam profiles at the tagged photon beam of the PHOENICS experiment at the electron stretcher ring ELSA in Bonn are given. (orig.)

  4. Influence of time of placement of investments for burnout and the type of rings being used on the casting accuracy.

    Science.gov (United States)

    Shah, Shabir A; Naqash, Talib Amin; Padmanabhan, T V; Subramanium; Lambodaran; Nazir, Shazana

    2014-03-01

    The sole objective of casting procedure is to provide a metallic duplication of missing tooth structure, with as great accuracy as possible. The ability to produce well fitting castings require strict adherence to certain fundamentals. A study was undertaken to comparatively evaluate the effect on casting accuracy by subjecting the invested wax patterns to burnout after different time intervals. The effect on casting accuracy using metal ring into a pre heated burnout furnace and using split ring was also carried. The readings obtained were tabulated and subjected to statistical analysis.

  5. Electron density and temperature profile diagnostics for C-2 field reversed configuration plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Deng, B. H.; Kinley, J. S.; Schroeder, J. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States)

    2012-10-15

    The 9-point Thomson scattering diagnostic system for the C-2 field reversed configuration plasmas is improved and the measured electron temperature profiles are consistent with theoretical expectations. Rayleigh scattering revealed a finite line width of the ruby laser emission, which complicates density calibration. Taking advantage of the plasma wobble motion, density profile reconstruction accuracy from the 6-chord two-color CO{sub 2}/HeNe interferometer data is improved.

  6. Preliminary studies into profiling DNA recovered from a radiation or radioactivity incident

    International Nuclear Information System (INIS)

    Hodgson, A.; Baxter, A.

    2013-01-01

    The examination and profiling of human DNA recovered from a scene of crime is an essential aspect of criminal investigations. However, it is currently not known whether DNA recovered from a scene where an ionising radiation source or radioactive contamination is present can be successfully profiled. The direct examination and analysis of radioactively contaminated DNA has not been widely explored using the current procedures employed by forensic service providers. As a result, AWE is putting in place an extensive research and development programme to better understand the effects that radiation has on the ability to profile human DNA, and assess the associated retention of different radioactive contaminants within each step of the profiling procedure. A summary will be provided on the aims of this project and progress that has been made to date; together with a discussion of the lessons that have been learnt during the course of the programme's development. (author)

  7. Masonry Procedures. Building Maintenance. Module V. Instructor's Guide.

    Science.gov (United States)

    Eck, Francis

    This curriculum guide, one of six modules keyed to the building maintenance competency profile developed by industry and education professionals, provides materials for a masonry procedures unit containing eight lessons. Lesson topics are masonry safety practices; set forms; mix concrete; patch and/or repair concrete; pour and finish concrete; mix…

  8. The Case for Laboratory Developed Procedures

    Directory of Open Access Journals (Sweden)

    Karen L. Kaul MD, PhD

    2017-07-01

    Full Text Available An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories.

  9. Aerial photogrammetry procedure optimized for micro uav

    Directory of Open Access Journals (Sweden)

    T. Anai

    2014-06-01

    Full Text Available This paper proposes the automatic aerial photogrammetry procedure optimized for Micro UAV that has ability of autonomous flight. The most important goal of our proposed method is the reducing the processing cost for fully automatic reconstruction of DSM from a large amount of image obtained from Micro UAV. For this goal, we have developed automatic corresponding point generation procedure using feature point tracking algorithm considering position and attitude information, which obtained from onboard GPS-IMU integrated on Micro UAV. In addition, we have developed the automatic exterior orientation and registration procedure from the automatic generated corresponding points on each image and position and attitude information from Micro UAV. Moreover, in order to reconstruct precise DSM, we have developed the area base matching process which considering edge information. In this paper, we describe processing flow of our automatic aerial photogrammetry. Moreover, the accuracy assessment is also described. Furthermore, some application of automatic reconstruction of DSM will be desired.

  10. Disinfection procedures: their efficacy and effect on dimensional accuracy and surface quality of an irreversible hydrocolloid impression material.

    LENUS (Irish Health Repository)

    Rentzia, A

    2011-02-01

    This study investigated the antibacterial efficacy and effect of 0.55% ortho-phthalaldehyde (Cidex OPA(®)) and 0.5% sodium hypochlorite (NaOCl) on the dimensional accuracy and surface quality of gypsum casts retrieved from an irreversible hydrocolloid impression material.

  11. An improved procedure for determining grain boundary diffusion coefficients from averaged concentration profiles

    Science.gov (United States)

    Gryaznov, D.; Fleig, J.; Maier, J.

    2008-03-01

    Whipple's solution of the problem of grain boundary diffusion and Le Claire's relation, which is often used to determine grain boundary diffusion coefficients, are examined for a broad range of ratios of grain boundary to bulk diffusivities Δ and diffusion times t. Different reasons leading to errors in determining the grain boundary diffusivity (DGB) when using Le Claire's relation are discussed. It is shown that nonlinearities of the diffusion profiles in lnCav-y6/5 plots and deviations from "Le Claire's constant" (-0.78) are the major error sources (Cav=averaged concentration, y =coordinate in diffusion direction). An improved relation (replacing Le Claire's constant) is suggested for analyzing diffusion profiles particularly suited for small diffusion lengths (short times) as often required in diffusion experiments on nanocrystalline materials.

  12. A Stepwise Fitting Procedure for automated fitting of Ecopath with Ecosim models

    Directory of Open Access Journals (Sweden)

    Erin Scott

    2016-01-01

    Full Text Available The Stepwise Fitting Procedure automates testing of alternative hypotheses used for fitting Ecopath with Ecosim (EwE models to observation reference data (Mackinson et al. 2009. The calibration of EwE model predictions to observed data is important to evaluate any model that will be used for ecosystem based management. Thus far, the model fitting procedure in EwE has been carried out manually: a repetitive task involving setting >1000 specific individual searches to find the statistically ‘best fit’ model. The novel fitting procedure automates the manual procedure therefore producing accurate results and lets the modeller concentrate on investigating the ‘best fit’ model for ecological accuracy.

  13. Receiver operating characteristic analysis of eyewitness memory: comparing the diagnostic accuracy of simultaneous versus sequential lineups.

    Science.gov (United States)

    Mickes, Laura; Flowe, Heather D; Wixted, John T

    2012-12-01

    A police lineup presents a real-world signal-detection problem because there are two possible states of the world (the suspect is either innocent or guilty), some degree of information about the true state of the world is available (the eyewitness has some degree of memory for the perpetrator), and a decision is made (identifying the suspect or not). A similar state of affairs applies to diagnostic tests in medicine because, in a patient, the disease is either present or absent, a diagnostic test yields some degree of information about the true state of affairs, and a decision is made about the presence or absence of the disease. In medicine, receiver operating characteristic (ROC) analysis is the standard method for assessing diagnostic accuracy. By contrast, in the eyewitness memory literature, this powerful technique has never been used. Instead, researchers have attempted to assess the diagnostic performance of different lineup procedures using methods that cannot identify the better procedure (e.g., by computing a diagnosticity ratio). Here, we describe the basics of ROC analysis, explaining why it is needed and showing how to use it to measure the performance of different lineup procedures. To illustrate the unique advantages of this technique, we also report 3 ROC experiments that were designed to investigate the diagnostic accuracy of simultaneous versus sequential lineups. According to our findings, the sequential procedure appears to be inferior to the simultaneous procedure in discriminating between the presence versus absence of a guilty suspect in a lineup.

  14. An appraisal profile of nostalgia.

    Science.gov (United States)

    van Tilburg, Wijnand A P; Bruder, Martin; Wildschut, Tim; Sedikides, Constantine; Göritz, Anja S

    2018-03-05

    The authors aimed to (a) identify the cognitive appraisals underlying nostalgia and (b) compare nostalgia with other emotions in terms of its appraisal profile. In Study 1, participants (N = 1,125) generated narratives. Next, they reported the level of nostalgia and 31 other emotions that these narratives elicited. Subsequently, participants evaluated the narrative events on several cognitive appraisals. Events that elicited nostalgia were pleasant, involved an irretrievable loss, felt psychologically distant, and were unique-an appraisal profile that differed from all other emotions. In Study 2 (N = 1,261), the authors experimentally varied these appraisals in a vignette paradigm and measured anticipated nostalgia and 10 other emotions. Participants anticipated most nostalgia when events were pleasant, involved irretrievable loss, were distant, and were unique-a profile shared only with longing. In Study 3 (N = 994), the authors used a guided autobiographical recall procedure in which they manipulated appraisals and measured the resultant emotions. Corroborating Studies 1-2, nostalgia was most intense for events that were pleasant, irretrievably lost, temporally distant, and unique. This appraisal profile was not shared by other emotions. The findings delineate the distinguishing cognitive appraisal profile of nostalgia. Nostalgia occupies a special place in the pantheon of emotions. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  15. EFFECT OF BASIC SKILLS IN ANY SITUATION TESTS ACCURACY YOUNG PLAYERS

    Directory of Open Access Journals (Sweden)

    Artan R. Kryeziu

    2013-07-01

    Full Text Available The paper aims to establish the impact of basic motor skills in some situational accuracy tests in youth basketball game. In a sample of 60 tested age of 17 year + / - 6 months. We have applied eigjt variables to the tested persons, five of which are predicting, while the other three are criterion tests. Connectivity between motor variables is handled through the correlation of Pearson. The impact of variables predicting in those criteria used in regression analysis. Also significant importance is given to the introduction of connectivity between basic motor skills in several accuracy tests typical for the basketball game situations. Regarding the basic motor skills variables have attained significant coherence, however situational space test throwing the ball in the basket in the same direction and shooting the ball in the basket in the corner 450 degres no coherence with any test has been shown from the space of the appility of basic motor skills. Through regression analysis procedure we’ve reviewed the impact of basic motor skills in some situational accuracy tests. Treat analysis of criterion variables in those predicting we can say that accuracy to situational variables impact junior league players had explosive force. Therefore we can conclude that explosive strength is a quite important factor in the game between young basketball players, with there moving actions the playes can achive their goal of scoring points.

  16. Metagenome Fragment Classification Using -Mer Frequency Profiles

    Directory of Open Access Journals (Sweden)

    Gail Rosen

    2008-01-01

    Full Text Available A vast amount of microbial sequencing data is being generated through large-scale projects in ecology, agriculture, and human health. Efficient high-throughput methods are needed to analyze the mass amounts of metagenomic data, all DNA present in an environmental sample. A major obstacle in metagenomics is the inability to obtain accuracy using technology that yields short reads. We construct the unique -mer frequency profiles of 635 microbial genomes publicly available as of February 2008. These profiles are used to train a naive Bayes classifier (NBC that can be used to identify the genome of any fragment. We show that our method is comparable to BLAST for small 25 bp fragments but does not have the ambiguity of BLAST's tied top scores. We demonstrate that this approach is scalable to identify any fragment from hundreds of genomes. It also performs quite well at the strain, species, and genera levels and achieves strain resolution despite classifying ubiquitous genomic fragments (gene and nongene regions. Cross-validation analysis demonstrates that species-accuracy achieves 90% for highly-represented species containing an average of 8 strains. We demonstrate that such a tool can be used on the Sargasso Sea dataset, and our analysis shows that NBC can be further enhanced.

  17. Virtual environment assessment for laser-based vision surface profiling

    Science.gov (United States)

    ElSoussi, Adnane; Al Alami, Abed ElRahman; Abu-Nabah, Bassam A.

    2015-03-01

    Oil and gas businesses have been raising the demand from original equipment manufacturers (OEMs) to implement a reliable metrology method in assessing surface profiles of welds before and after grinding. This certainly mandates the deviation from the commonly used surface measurement gauges, which are not only operator dependent, but also limited to discrete measurements along the weld. Due to its potential accuracy and speed, the use of laser-based vision surface profiling systems have been progressively rising as part of manufacturing quality control. This effort presents a virtual environment that lends itself for developing and evaluating existing laser vision sensor (LVS) calibration and measurement techniques. A combination of two known calibration techniques is implemented to deliver a calibrated LVS system. System calibration is implemented virtually and experimentally to scan simulated and 3D printed features of known profiles, respectively. Scanned data is inverted and compared with the input profiles to validate the virtual environment capability for LVS surface profiling and preliminary assess the measurement technique for weld profiling applications. Moreover, this effort brings 3D scanning capability a step closer towards robust quality control applications in a manufacturing environment.

  18. Suicide news reporting accuracy and stereotyping in Hong Kong.

    Science.gov (United States)

    Cheng, Qijin; Yip, Paul S F

    2012-12-10

    The mass media are often criticized for oversimplifying the causes of suicide and overlooking some of the risk factors. However, there is a lack of empirical evidence to support this assertion. The study aims to examine the accuracy of news reports in Hong Kong (HK) and in particular whether or not such reports stereotype victims according to gender and suicide method. Data from a case-control psychological autopsy (PA) study of 150 HK suicides were utilized. The reports of the PA cases from five major HK newspapers were collected and reviewed to identify whether or not there was a match in terms of the cases' profile and risk factors. The age, gender, and method of the suicides were largely reported correctly (>70%) but accounts of risk factors were seldom accurate (Media stereotyping of gender-specific suicide and charcoal-burning suicide was identified. The study was based on a HK sample so the findings are not necessarily applicable elsewhere. The HK mass media generally demonstrated poor accuracy in reporting suicide risk factors. Their reporting was also problematic in terms of stereotyping gender- and method-specific suicides. Clinical practitioners should be alerted to these findings when working with the media. They can also adopt this novel usage of PA data to extract further information from other PA studies and thereby broaden the investigation of reporting accuracy and stereotyping of suicide to more diverse social contexts. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. The development of retrosynthetic glycan libraries to profile and classify the human serum N-linked glycome.

    Science.gov (United States)

    Kronewitter, Scott R; An, Hyun Joo; de Leoz, Maria Lorna; Lebrilla, Carlito B; Miyamoto, Suzanne; Leiserowitz, Gary S

    2009-06-01

    Annotation of the human serum N-linked glycome is a formidable challenge but is necessary for disease marker discovery. A new theoretical glycan library was constructed and proposed to provide all possible glycan compositions in serum. It was developed based on established glycobiology and retrosynthetic state-transition networks. We find that at least 331 compositions are possible in the serum N-linked glycome. By pairing the theoretical glycan mass library with a high mass accuracy and high-resolution MS, human serum glycans were effectively profiled. Correct isotopic envelope deconvolution to monoisotopic masses and the high mass accuracy instruments drastically reduced the amount of false composition assignments. The high throughput capacity enabled by this library permitted the rapid glycan profiling of large control populations. With the use of the library, a human serum glycan mass profile was developed from 46 healthy individuals. This paper presents a theoretical N-linked glycan mass library that was used for accurate high-throughput human serum glycan profiling. Rapid methods for evaluating a patient's glycome are instrumental for studying glycan-based markers.

  20. ACCURACY ASSESSMENT OF UNDERWATER PHOTOGRAMMETRIC THREE DIMENSIONAL MODELLING FOR CORAL REEFS

    Directory of Open Access Journals (Sweden)

    T. Guo

    2016-06-01

    Full Text Available Recent advances in automation of photogrammetric 3D modelling software packages have stimulated interest in reconstructing highly accurate 3D object geometry in unconventional environments such as underwater utilizing simple and low-cost camera systems. The accuracy of underwater 3D modelling is affected by more parameters than in single media cases. This study is part of a larger project on 3D measurements of temporal change of coral cover in tropical waters. It compares the accuracies of 3D point clouds generated by using images acquired from a system camera mounted in an underwater housing and the popular GoPro cameras respectively. A precisely measured calibration frame was placed in the target scene in order to provide accurate control information and also quantify the errors of the modelling procedure. In addition, several objects (cinder blocks with various shapes were arranged in the air and underwater and 3D point clouds were generated by automated image matching. These were further used to examine the relative accuracy of the point cloud generation by comparing the point clouds of the individual objects with the objects measured by the system camera in air (the best possible values. Given a working distance of about 1.5 m, the GoPro camera can achieve a relative accuracy of 1.3 mm in air and 2.0 mm in water. The system camera achieved an accuracy of 1.8 mm in water, which meets our requirements for coral measurement in this system.

  1. Perspectives on "Bakke": Equal Protection, Procedural Fairness, or Structural Justice?

    Science.gov (United States)

    Tribe, Laurence H.

    1979-01-01

    The "Bakke" case is examined for what it has to say regarding first the area of equal protection, then the idea of procedural fairness as distinct from accuracy of result, and finally the notion of structural justice. Available from Harvard Law Review, Harvard Law Review Association, Gannett House, Cambridge, Massachusetts 02138; sc…

  2. Pulsed photothermal profiling of water-based samples using a spectrally composite reconstruction approach

    International Nuclear Information System (INIS)

    Majaron, B; Milanic, M

    2010-01-01

    Pulsed photothermal profiling involves reconstruction of temperature depth profile induced in a layered sample by single-pulse laser exposure, based on transient change in mid-infrared (IR) emission from its surface. Earlier studies have indicated that in watery tissues, featuring a pronounced spectral variation of mid-IR absorption coefficient, analysis of broadband radiometric signals within the customary monochromatic approximation adversely affects profiling accuracy. We present here an experimental comparison of pulsed photothermal profiling in layered agar gel samples utilizing a spectrally composite kernel matrix vs. the customary approach. By utilizing a custom reconstruction code, the augmented approach reduces broadening of individual temperature peaks to 14% of the absorber depth, in contrast to 21% obtained with the customary approach.

  3. Preschoolers' Person Description and Identification Accuracy: A Comparison of the Simultaneous and Elimination Lineup Procedures

    Science.gov (United States)

    Pozzulo, Joanna D.; Dempsey, Julie; Crescini, Charmagne

    2009-01-01

    Preschoolers' (3- to 6-year-olds) person description and identification abilities were examined using the simultaneous and elimination lineup procedures. Participants (N = 100) were exposed to a 20-minute mask-making session conducted by a female confederate who acted as the mask-making teacher. After a brief delay (20 min), participants were…

  4. Accuracy of 3 different impression techniques for internal connection angulated implants.

    Science.gov (United States)

    Tsagkalidis, George; Tortopidis, Dimitrios; Mpikos, Pavlos; Kaisarlis, George; Koidis, Petros

    2015-10-01

    Making implant impressions with different angulations requires a more precise and time-consuming impression technique. The purpose of this in vitro study was to compare the accuracy of nonsplinted, splinted, and snap-fit impression techniques of internal connection implants with different angulations. An experimental device was used to allow a clinical simulation of impression making by means of open and closed tray techniques. Three different impression techniques (nonsplinted, acrylic-resin splinted, and indirect snap-fit) for 6 internal-connected implants at different angulations (0, 15, 25 degrees) were examined using polyether. Impression accuracy was evaluated by measuring the differences in 3-dimensional (3D) position deviations between the implant body/impression coping before the impression procedure and the coping/laboratory analog positioned within the impression, using a coordinate measuring machine. Data were analyzed by 2-way ANOVA. Means were compared with the least significant difference criterion at Pimpression technique exhibited a higher accuracy than the other techniques studied when increased implant angulations at 25 degrees were involved. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Accurate registration of peri-implant soft tissues to create an optimal emergence profile

    Directory of Open Access Journals (Sweden)

    Ibraheem Fahad Alshiddi

    2015-01-01

    Full Text Available One of the challenges in restoring anterior space with implant restoration is maintaining the natural looking of peri-implant area. This case report presents a clinical procedure to create the soft tissue emergence profile for anterior maxillary teeth. A 49-year-old male presented with missing right maxillary lateral incisor. A provisional restoration was inserted 1 week after implant placement. Area of the provisional restoration related to the gingival tissue (transmucosal area was adjusted to create an optimum emergence profile. Two months later, an indirect method was used to accurately transfer the soft peri-implant tissues to the master cast. This clinical technique minimizes surgical procedure and avoids the possibility of soft tissue collapsing that may occur during the impression procedure.

  6. Complications, disease profile and histological yield from ...

    African Journals Online (AJOL)

    Objective. The objective of the study was to evaluate (i) the technique used at Universitas Hospital in comparison with other international centres also performing renal biopsies, (ii) the disease profile in patients undergoing renal biopsies, (iii) the complications experienced during and/or after the procedure, and (iv) the ...

  7. Temperature profiles by ground-based remote sensing and in situ measurements

    Energy Technology Data Exchange (ETDEWEB)

    Argentini, S; Pietroni, I; Conidi, A; Mastrantonio, G; Petenko, I; Viola, A [ISAC-CNR, Via del Fosso del Cavaliere, 100, 00133 Roma (Italy); Gariazzo, C; Pelliccioni, A; Amicarelli, A [ISPESL Dipartimento Insediamenti Produttivi e Interazione con l' Ambiente, Via Fontana Candida, 1, 00040 Monteporzio Catone (RM) (Italy)], E-mail: s.argentini@isac.cnr.it

    2008-05-01

    This study focuses on the accuracy of the temperature profiles measured with a Doppler Radio-Acoustic Sounding System and a Microwave Temperature Profiler during a period of about 3 months in winter 2007-2008. The experiment was carried on at the experimental facility of the Institute of Atmospheric Sciences and Climate (ISAC) of the Italian National Research Council (CNR). The temperature data measured with remote sensors were verified with in situ measurements on a mast as well as with tethered balloon data. The facsimile echograms obtained with the ISAC Doppler SODAR were analysed to understand to which extent the RASS and Radiometer temperature profiles behaviour can represent the real thermal structure of the atmosphere.

  8. Temperature profiles by ground-based remote sensing and in situ measurements

    International Nuclear Information System (INIS)

    Argentini, S; Pietroni, I; Conidi, A; Mastrantonio, G; Petenko, I; Viola, A; Gariazzo, C; Pelliccioni, A; Amicarelli, A

    2008-01-01

    This study focuses on the accuracy of the temperature profiles measured with a Doppler Radio-Acoustic Sounding System and a Microwave Temperature Profiler during a period of about 3 months in winter 2007-2008. The experiment was carried on at the experimental facility of the Institute of Atmospheric Sciences and Climate (ISAC) of the Italian National Research Council (CNR). The temperature data measured with remote sensors were verified with in situ measurements on a mast as well as with tethered balloon data. The facsimile echograms obtained with the ISAC Doppler SODAR were analysed to understand to which extent the RASS and Radiometer temperature profiles behaviour can represent the real thermal structure of the atmosphere

  9. Pediatric procedural sedation and analgesia

    Directory of Open Access Journals (Sweden)

    Meredith James

    2008-01-01

    Full Text Available Procedural sedation and analgesia (PSA is an evolving field in pediatric emergency medicine. As new drugs breach the boundaries of anesthesia in the Pediatric Emergency Department, parents, patients, and physicians are finding new and more satisfactory methods of sedation. Short acting, rapid onset agents with little or no lingering effects and improved safety profiles are replacing archaic regimens. This article discusses the warning signs and areas of a patient′s medical history that are particularly pertinent to procedural sedation and the drugs used. The necessary equipment is detailed to provide the groundwork for implementing safe sedation in children. It is important for practitioners to familiarize themselves with a select few of the PSA drugs, rather than the entire list of sedatives. Those agents most relevant to PSA in the pediatric emergency department are presented.

  10. Testing the accuracy of remote sensing land use maps

    Science.gov (United States)

    Vangenderen, J. L.; Lock, B. F.; Vass, P. A.

    1977-01-01

    Some of the main aspects that need to be considered in a remote sensing sampling design are: (1) the frequency that any one land use type (on the ground) is erroneously attributed to another class by the interpreter; (2) the frequency that the wrong land use (as observed on the ground) is erroneously included in any one class by the remote sensing interpreter; (3) the proportion of all land (as determined in the field) that is mistakenly attributed by the interpreter; and (4) the determination of whether the mistakes are random (so that the overall proportions are approximately correct) or subject to a persistent bias. A sampling and statistical testing procedure is presented which allows an approximate answer to each of these aspects. The concept developed and described incorporates the probability of making incorrect interpretations at particular prescribed accuracy levels, for a certain number of errors, for a particular sample size. It is considered that this approach offers a meaningful explanation of the interpretation accuracy level of an entire remote sensing land use survey.

  11. The effects of divided attention at study and reporting procedure on regulation and monitoring for episodic recall.

    Science.gov (United States)

    Sauer, James; Hope, Lorraine

    2016-09-01

    Eyewitnesses regulate the level of detail (grain size) reported to balance competing demands for informativeness and accuracy. However, research to date has predominantly examined metacognitive monitoring for semantic memory tasks, and used relatively artificial phased reporting procedures. Further, although the established role of confidence in this regulation process may affect the confidence-accuracy relation for volunteered responses in predictable ways, previous investigations of the confidence-accuracy relation for eyewitness recall have largely overlooked the regulation of response granularity. Using a non-phased paradigm, Experiment 1 compared reporting and monitoring following optimal and sub-optimal (divided attention) encoding conditions. Participants showed evidence of sacrificing accuracy for informativeness, even when memory quality was relatively weak. Participants in the divided (cf. full) attention condition showed reduced accuracy for fine- but not coarse-grained responses. However, indices of discrimination and confidence diagnosticity showed no effect of divided attention. Experiment 2 compared the effects of divided attention at encoding on reporting and monitoring using both non-phased and 2-phase procedures. Divided attention effects were consistent with Experiment 1. However, compared to those in the non-phased condition, participants in the 2-phase condition displayed a more conservative control strategy, and confidence ratings were less diagnostic of accuracy. When memory quality was reduced, although attempts to balance informativeness and accuracy increased the chance of fine-grained response errors, confidence provided an index of the likely accuracy of volunteered fine-grained responses for both condition. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. ACCURACY ASSESSMENT OF MOBILE MAPPING POINT CLOUDS USING THE EXISTING ENVIRONMENT AS TERRESTRIAL REFERENCE

    Directory of Open Access Journals (Sweden)

    S. Hofmann

    2016-06-01

    Full Text Available Mobile mapping data is widely used in various applications, what makes it especially important for data users to get a statistically verified quality statement on the geometric accuracy of the acquired point clouds or its processed products. The accuracy of point clouds can be divided into an absolute and a relative quality, where the absolute quality describes the position of the point cloud in a world coordinate system such as WGS84 or UTM, whereas the relative accuracy describes the accuracy within the point cloud itself. Furthermore, the quality of processed products such as segmented features depends on the global accuracy of the point cloud but mainly on the quality of the processing steps. Several data sources with different characteristics and quality can be thought of as potential reference data, such as cadastral maps, orthophoto, artificial control objects or terrestrial surveys using a total station. In this work a test field in a selected residential area was acquired as reference data in a terrestrial survey using a total station. In order to reach high accuracy the stationing of the total station was based on a newly made geodetic network with a local accuracy of less than 3 mm. The global position of the network was determined using a long time GNSS survey reaching an accuracy of 8 mm. Based on this geodetic network a 3D test field with facades and street profiles was measured with a total station, each point with a two-dimensional position and altitude. In addition, the surface of poles of street lights, traffic signs and trees was acquired using the scanning mode of the total station. Comparing this reference data to the acquired mobile mapping point clouds of several measurement campaigns a detailed quality statement on the accuracy of the point cloud data is made. Additionally, the advantages and disadvantages of the described reference data source concerning availability, cost, accuracy and applicability are discussed.

  13. An in-vitro investigation of the accuracy of fit of Procera and Empress crowns.

    Science.gov (United States)

    Fleming, Garry J R; Dobinson, Marie M; Landini, Gabriel; Harris, Jonathan J

    2005-09-01

    The current study aimed to investigate the accuracy of fit and the reproducibility of inner crown profile for two types of high strength ceramics, IPS Empress and Procera. Procera and Empress crowns with four different morphologies were cemented to dies using zinc phosphate dental cement. Vertical and horizontal sections were made through each of the crown/die preparations and images of the vertical sections were compared for curvature reproduction by alignment using image processing. Measurements were made on horizontal sections to determine cement layer thickness. Alignment of the crowns using image analysis identified quantifiable variations in the inner surface profile compared with the outer surface of the die. The largest differences occurred from the cusp tips to the occlusal adaptation area and differences in surface profile were less pronounced for Procera than Empress crowns. Marginal gap varied independently of ceramic or internal crown shape from 7-529 microm for Procera and 26-548 microm for Empress. IPS Empress has a superior ability to reproduce the inner surface profile of the crown morphologies investigated compared with Procera. The reduced reproduction of surface profile was associated with an increased cement thickness at the occlusal contact area that may inadvertently lead to failure of the crowns functional characteristics.

  14. Reconstruction of original indium distribution in InGaAs quantum wells from experimental SIMS depth profiles

    Energy Technology Data Exchange (ETDEWEB)

    Kudriavtsev, Yu., E-mail: yuriyk@cinvestav.mx [Departamento Ingeniería Eléctrica – SEES, CINVESTAV-IPN, Av. IPN #2508, D.F., México (Mexico); Asomoza, R. [Departamento Ingeniería Eléctrica – SEES, CINVESTAV-IPN, Av. IPN #2508, D.F., México (Mexico); Gallardo-Hernandez, S.; Ramirez-Lopez, M.; Lopez-Lopez, M. [Departamento de Física, CINVESTAV-IPN, México (Mexico); Nevedomsky, V.; Moiseev, K. [Ioffe Physical Technical Institute, S-Petersburg (Russian Federation)

    2014-11-15

    Depth profiling analysis of InGaAs/GaAs hetero-structures grown by MBE on GaAs (0 0 1) substrates is reported. A novel two-step procedure for de-convolving experimental SIMS depth distribution is employed and the original In distribution in InGaAs quantum wells (QW) is estimated. The QW thickness calculated from the de-convolved profiles is shown to be in good agreement with the cross-sectional TEM images. The experimental In depth profile is shifted from the original In distribution due to the ion mixing process during depth profiling analysis. It is shown that the de-convolution procedure is suitable for reconstruction of the original QW width and depth by SIMS even for relatively high primary ion energies.

  15. Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

    Science.gov (United States)

    Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans

    2015-01-01

    MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.

  16. Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Jan Stefan Bauer

    Full Text Available MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo.MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days. This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence.In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility.With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.

  17. A beam profile monitor for a tagged photon beam

    International Nuclear Information System (INIS)

    Arends, J.; Breuer, M.; Dahmen, H.D.; Detemple, P.; Noeldeke, G.; Schneider, W.; Zucht, B.

    1990-10-01

    A beam profile monitor for electron and photon beams is described, which operates at the low intensities encountered in a tagged bremsstrahlung beam environment, typically 10 10 electrons/s and 10 7 photons/s. The method is based on a wire scanner and utilizes the presence of a tagging spectrometer. The accuracy of the measurements can be tuned in a wide range (at the expense of measuring time) to meet the requirements set by the actual beam size. Examples of measured electron and photon beam profiles at the tagged photon beam of the PHOENICS experiment at the electron stretcher ring ELSA are given. (orig.)

  18. A beam profile monitor for a tagged photon beam

    Energy Technology Data Exchange (ETDEWEB)

    Arends, J.; Breuer, M.; Dahmen, H.D.; Detemple, P.; Noeldeke, G.; Schneider, W.; Zucht, B.

    1990-10-01

    A beam profile monitor for electron and photon beams is described, which operates at the low intensities encountered in a tagged bremsstrahlung beam environment, typically 10{sup 10} electrons/s and 10{sup 7} photons/s. The method is based on a wire scanner and utilizes the presence of a tagging spectrometer. The accuracy of the measurements can be tuned in a wide range (at the expense of measuring time) to meet the requirements set by the actual beam size. Examples of measured electron and photon beam profiles at the tagged photon beam of the PHOENICS experiment at the electron stretcher ring ELSA are given. (orig.).

  19. Enhancing lineup identification accuracy: two codes are better than one.

    Science.gov (United States)

    Melara, R D; DeWitt-Rickards, T S; O'Brien, T P

    1989-10-01

    Ways of improving identification accuracy were explored by comparing the conventional visual lineup with an auditory/visual lineup, one that paired color photographs with voice recordings. This bimodal lineup necessitated sequential presentation of lineup members; Experiment 1 showed that performance in sequential lineups was better than performance in traditional simultaneous lineups. In Experiments 2A and 2B unimodal and bimodal lineups were compared by using a multiple-lineup paradigm: Ss viewed 3 videotaped episodes depicting standard police procedures and were tested in 4 sequential lineups. Bimodal lineups were more diagnostic than either visual or auditory lineups alone. The bimodal lineup led to a 126% improvement in number of correct identifications over the conventional visual lineup, with no concomitant increase in number of false identifications. These results imply strongly that bimodal procedures should be adopted in real-world lineups. The nature of memorial processes underlying this bimodal advantage is discussed.

  20. Determination of optimal ultrasound planes for the initialisation of image registration during endoscopic ultrasound-guided procedures.

    Science.gov (United States)

    Bonmati, Ester; Hu, Yipeng; Gibson, Eli; Uribarri, Laura; Keane, Geri; Gurusami, Kurinchi; Davidson, Brian; Pereira, Stephen P; Clarkson, Matthew J; Barratt, Dean C

    2018-06-01

    Navigation of endoscopic ultrasound (EUS)-guided procedures of the upper gastrointestinal (GI) system can be technically challenging due to the small fields-of-view of ultrasound and optical devices, as well as the anatomical variability and limited number of orienting landmarks during navigation. Co-registration of an EUS device and a pre-procedure 3D image can enhance the ability to navigate. However, the fidelity of this contextual information depends on the accuracy of registration. The purpose of this study was to develop and test the feasibility of a simulation-based planning method for pre-selecting patient-specific EUS-visible anatomical landmark locations to maximise the accuracy and robustness of a feature-based multimodality registration method. A registration approach was adopted in which landmarks are registered to anatomical structures segmented from the pre-procedure volume. The predicted target registration errors (TREs) of EUS-CT registration were estimated using simulated visible anatomical landmarks and a Monte Carlo simulation of landmark localisation error. The optimal planes were selected based on the 90th percentile of TREs, which provide a robust and more accurate EUS-CT registration initialisation. The method was evaluated by comparing the accuracy and robustness of registrations initialised using optimised planes versus non-optimised planes using manually segmented CT images and simulated ([Formula: see text]) or retrospective clinical ([Formula: see text]) EUS landmarks. The results show a lower 90th percentile TRE when registration is initialised using the optimised planes compared with a non-optimised initialisation approach (p value [Formula: see text]). The proposed simulation-based method to find optimised EUS planes and landmarks for EUS-guided procedures may have the potential to improve registration accuracy. Further work will investigate applying the technique in a clinical setting.

  1. Accuracy of three-dimensional seismic ground response analysis in time domain using nonlinear numerical simulations

    Science.gov (United States)

    Liang, Fayun; Chen, Haibing; Huang, Maosong

    2017-07-01

    To provide appropriate uses of nonlinear ground response analysis for engineering practice, a three-dimensional soil column with a distributed mass system and a time domain numerical analysis were implemented on the OpenSees simulation platform. The standard mesh of a three-dimensional soil column was suggested to be satisfied with the specified maximum frequency. The layered soil column was divided into multiple sub-soils with a different viscous damping matrix according to the shear velocities as the soil properties were significantly different. It was necessary to use a combination of other one-dimensional or three-dimensional nonlinear seismic ground analysis programs to confirm the applicability of nonlinear seismic ground motion response analysis procedures in soft soil or for strong earthquakes. The accuracy of the three-dimensional soil column finite element method was verified by dynamic centrifuge model testing under different peak accelerations of the earthquake. As a result, nonlinear seismic ground motion response analysis procedures were improved in this study. The accuracy and efficiency of the three-dimensional seismic ground response analysis can be adapted to the requirements of engineering practice.

  2. Procedure for the automatic mesh generation of innovative gear teeth

    Directory of Open Access Journals (Sweden)

    Radicella Andrea Chiaramonte

    2016-01-01

    Full Text Available After having described gear wheels with teeth having the two sides constituted by different involutes and their importance in engineering applications, we stress the need for an efficient procedure for the automatic mesh generation of innovative gear teeth. First, we describe the procedure for the subdivision of the tooth profile in the various possible cases, then we show the method for creating the subdivision mesh, defined by two series of curves called meridians and parallels. Finally, we describe how the above procedure for automatic mesh generation is able to solve specific cases that may arise when dealing with teeth having the two sides constituted by different involutes.

  3. Effect of Continuous Glucose Monitoring Accuracy on Clinicians' Retrospective Decision Making in Diabetes: A Pilot Study

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Johansen, Mette Dencker; Nørgaard, Hanne Holdflod

    2015-01-01

    BACKGROUND: The use of continuous glucose monitoring (CGM) in clinical decision making in diabetes could be limited by the inaccuracy of CGM data when compared to plasma glucose measurements. The aim of the present study is to investigate the impact of CGM numerical accuracy on the precision...... of diabetes treatment adjustments. METHOD: CGM profiles with maximum 5-day duration from 12 patients with type 1 diabetes treated with a basal-bolus insulin regimen were processed by 2 CGM algorithms, with the accuracy of algorithm 2 being higher than the accuracy of algorithm 1, using the median absolute...... of the interclinician agreement and the intraclinician reproducibility of the decisions. The Cohen's kappa coefficient was used to assess the precision of the decisions. The study was based on retrospective and blind CGM data. RESULTS: For the interclinician agreement, in the first occasion, the kappa of algorithm 1...

  4. A web-based procedure for liver segmentation in CT images

    Science.gov (United States)

    Yuan, Rong; Luo, Ming; Wang, Luyao; Xie, Qingguo

    2015-03-01

    Liver segmentation in CT images has been acknowledged as a basic and indispensable part in systems of computer aided liver surgery for operation design and risk evaluation. In this paper, we will introduce and implement a web-based procedure for liver segmentation to help radiologists and surgeons get an accurate result efficiently and expediently. Several clinical datasets are used to evaluate the accessibility and the accuracy. This procedure seems a promising approach for extraction of liver volumetry of various shapes. Moreover, it is possible for user to access the segmentation wherever the Internet is available without any specific machine.

  5. High Accuracy Evaluation of the Finite Fourier Transform Using Sampled Data

    Science.gov (United States)

    Morelli, Eugene A.

    1997-01-01

    Many system identification and signal processing procedures can be done advantageously in the frequency domain. A required preliminary step for this approach is the transformation of sampled time domain data into the frequency domain. The analytical tool used for this transformation is the finite Fourier transform. Inaccuracy in the transformation can degrade system identification and signal processing results. This work presents a method for evaluating the finite Fourier transform using cubic interpolation of sampled time domain data for high accuracy, and the chirp Zeta-transform for arbitrary frequency resolution. The accuracy of the technique is demonstrated in example cases where the transformation can be evaluated analytically. Arbitrary frequency resolution is shown to be important for capturing details of the data in the frequency domain. The technique is demonstrated using flight test data from a longitudinal maneuver of the F-18 High Alpha Research Vehicle.

  6. What is beautiful is good and more accurately understood. Physical attractiveness and accuracy in first impressions of personality.

    Science.gov (United States)

    Lorenzo, Genevieve L; Biesanz, Jeremy C; Human, Lauren J

    2010-12-01

    Beautiful people are seen more positively than others, but are they also seen more accurately? In a round-robin design in which previously unacquainted individuals met for 3 min, results were consistent with the "beautiful is good" stereotype: More physically attractive individuals were viewed with greater normative accuracy; that is, they were viewed more in line with the highly desirable normative profile. Notably, more physically attractive targets were viewed more in line with their unique self-reported personality traits, that is, with greater distinctive accuracy. Further analyses revealed that both positivity and accuracy were to some extent in the eye of the beholder: Perceivers' idiosyncratic impressions of a target's attractiveness were also positively related to the positivity and accuracy of impressions. Overall, people do judge a book by its cover, but a beautiful cover prompts a closer reading, leading more physically attractive people to be seen both more positively and more accurately.

  7. ACCURACY RESEARCH OF THE DIAMETRICAL SIZES FORMING AT GEAR SHAPING BY STEPPED CUTTER

    Directory of Open Access Journals (Sweden)

    N. M. Rasulov

    2015-09-01

    Full Text Available The paper presents research results of forming accuracy for diametrical sizes at gear shaping with stepped cutter and the traditional method. Analysis of static technological dimensional pitch size chain of wheels being cut is performed. It was revealed that the most of transmission errors of the wheels, formed by the traditional gear-shaped cutter are caused by manufacturing and installation error of the cutter and result from the formation of each tooth of the wheel with a certain tool. This is not the case with gear shaping by step cutter since at that, the profiles of all gear teeth are formed by means of tooth profile mostly remote from the tool rotation axis. Analysis of occurrence of setting-up errors typical for the above gear shaping methods has been performed. At gear shaping with stepped cutter there are no setting-up error components. It was revealed that this fact causes the absence of errors in the tool position before its each double motion. The accuracy of diametrical sizes increases. Formation mechanism of tool installation errors and workpiece are also given and their analysis is presented. Findings in the field of gear shaping with stepped cutter comply with results of research carried out by the other authors in the field of traditional gear shaping.

  8. Evaluation of various digestion procedures for trace element contents of some food materials

    International Nuclear Information System (INIS)

    Demirel, Sule; Tuzen, Mustafa; Saracoglu, Sibel; Soylak, Mustafa

    2008-01-01

    The levels of trace elements in different types of food material consumed in Turkey were determined by flame and graphite furnace atomic absorption spectrometry. Food samples were digested with dry ashing, wet ashing and microwave digestion procedures in this study. The microwave digestion procedure was chosen for the digestion of all the food samples because it required shorter time and made higher recovery (specially for Se). Fe, Cu, Mn, Zn, Al and Se were determined by flame and graphite furnace atomic absorption spectrometry, respectively. Relative standard deviations (RSD) were found below 10%. The accuracy of the procedure was confirmed by certified reference materials. Moreover, this procedure was easier to use when compared with dry and wet digestions

  9. Development of procedures for programmable proximity aperture lithography

    Energy Technology Data Exchange (ETDEWEB)

    Whitlow, H.J., E-mail: harry.whitlow@he-arc.ch [Institut des Microtechnologies Appliquées Arc, Haute Ecole Arc Ingénierie, Eplatures-Grise 17, CH-2300 La Chaux-de-Fonds (Switzerland); Department of Physics, University of Jyväskylä, P.O. Box 35 (YFL), FI-40014 Jyväskylä (Finland); Gorelick, S. [VTT Technical Research Centre of Finland, P.O. Box 1000, Tietotie 3, Espoo, FI-02044 VTT (Finland); Puttaraksa, N. [Department of Physics, University of Jyväskylä, P.O. Box 35 (YFL), FI-40014 Jyväskylä (Finland); Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Napari, M.; Hokkanen, M.J.; Norarat, R. [Department of Physics, University of Jyväskylä, P.O. Box 35 (YFL), FI-40014 Jyväskylä (Finland)

    2013-07-01

    Programmable proximity aperture lithography (PPAL) with MeV ions has been used in Jyväskylä and Chiang Mai universities for a number of years. Here we describe a number of innovations and procedures that have been incorporated into the LabView-based software. The basic operation involves the coordination of the beam blanker and five motor-actuated translators with high accuracy, close to the minimum step size with proper anti-collision algorithms. By using special approaches, such writing calibration patterns, linearisation of position and careful backlash correction the absolute accuracy of the aperture size and position, can be improved beyond the standard afforded by the repeatability of the translator end-point switches. Another area of consideration has been the fluence control procedures. These involve control of the uniformity of the beam where different approaches for fluence measurement such as simultaneous aperture current and the ion current passing through the aperture using a Faraday cup are used. Microfluidic patterns may contain many elements that make-up mixing sections, reaction chambers, separation columns and fluid reservoirs. To facilitate conception and planning we have implemented a .svg file interpreter, that allows the use of scalable vector graphics files produced by standard drawing software for generation of patterns made up of rectangular elements.

  10. Accuracy of mechanical torque-limiting devices for dental implants.

    Science.gov (United States)

    L'Homme-Langlois, Emilie; Yilmaz, Burak; Chien, Hua-Hong; McGlumphy, Edwin

    2015-10-01

    A common complication in implant dentistry is unintentional implant screw loosening. The critical factor in the prevention of screw loosening is the delivery of the appropriate target torque value. Mechanical torque-limiting devices (MTLDs) are the most frequently recommended devices by the implant manufacturers to deliver the target torque value to the screw. Two types of MTLDs are available: friction-style and spring-style. Limited information is available regarding the influence of device type on the accuracy of MTLDs. The purpose of this study was to determine and compare the accuracy of spring-style and friction-style MTLDs. Five MTLDs from 6 different dental implant manufacturers (Astra Tech/Dentsply, Zimmer Dental, Biohorizons, Biomet 3i, Straumann [ITI], and Nobel Biocare) (n=5 per manufacturer) were selected to determine their accuracy in delivering target torque values preset by their manufacturers. All torque-limiting devices were new and there were 3 manufacturers for the friction-style and 3 manufacturers for the spring-style. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (Chatillon Model DFS2-R-ND; Ametek) was used to record the measurements. Statistical analysis used nonparametric tests to determine the accuracy of the MTLDs in delivering target torque values and Bonferroni post hoc tests were used to assess pairwise comparisons. Median absolute difference between delivered torque values and target torque values of friction-style and spring-style MTLDs were not significantly different (P>.05). Accuracy of Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly different than Biohorizons torque-limiting devices (Ptorque value. Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly more accurate than Biohorizons (C) torque-limiting devices (Ptorque-limiting devices fell within ±10% of the target torque value preset by the

  11. A comparative examination of sample treatment procedures for ICAP-AES analysis of biological tissue

    Science.gov (United States)

    De Boer, J. L. M.; Maessen, F. J. M. J.

    The objective of this study was to contribute to the evaluation of existing sample preparation procedures for ICAP-AES analysis of biological material. Performance characteristics were established of current digestion procedures comprising extraction, solubilization, pressure digestion, and wet and dry ashing methods. Apart from accuracy and precision, a number of criteria of special interest for the analytical practice was applied. As a test sample served SRM bovine liver. In this material six elements were simultaneously determined. Results showed that every procedure has its defects and advantages. Hence, unambiguous recommendation of standard digestion procedures can be made only when taking into account the specific analytical problem.

  12. A comparison of various procedures in photon activation analysis with the same irradiation setup

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z.J. [Chemical Sciences and Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave., Argonne, IL 60439 (United States); Wells, D. [Physics Department, South Dakota School of Mines and Technology, 501 E. Saint Joseph St., Rapid City, SD 57701 (United States); Segebade, C. [Idaho Accelerator Center, Idaho State University, 921 S. 8th Ave., Pocatello, ID 83209 (United States); Quigley, K.; Chemerisov, S. [Chemical Sciences and Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave., Argonne, IL 60439 (United States)

    2014-11-15

    A sample of known elemental concentrations was activated in the bremsstrahlung photon beam which was created by a pulsed electron LINAC. Several procedures of photon activation analysis, including those applied with/without reference material and with/without photon flux monitor, were conducted to make a comparison of their precision and accuracy in practice. Experimental results have indicated that: (1) relative procedures usually produce better outcome despite that the absolute measurement is straightforward and eliminate the assistance of reference materials; (2) among relative procedures, the method with internal flux monitor yields higher quality of the analytical results. In the article, the pros and cons of each procedure are discussed as well.

  13. Procedures of quality control of radiopharmaceutical activity counters

    International Nuclear Information System (INIS)

    Oliveira, A.E. de; Iwahara, A.; Gaast, H.A. van der; Buckman, S.M.

    1999-01-01

    The Radionuclides Metrology Supervision-Ionizing Radiation Metrology National Laboratory maintain and distributes the brazilian standards for radioactivity measurements. The Brazilian Institute for Metrology, Regulation and Industrial Quality (INMETRO), which is the brazilian authority for standards verification, is coordinating the enhancement of the standards distribution. Concerning to the nuclear medicine related radioisotopes, this network will provide for calibration of brazilian hospitals and clinics instruments, assuring great accuracy of the radiopharmaceuticals activities. This work gives details of the calibration quality control procedures recommended by the Radionuclides Metrology Supervisory (Brazilian National Nuclear Energy Commission) and the Radioactive Standards Division of the Australian Nuclear Technology and Science Organization (ANSTO). This information can be used as a guide for the brazilian nuclear medicine services guaranty on the accuracy and precision of the radiopharmaceuticals activity measurements measurements

  14. WAIS-III index score profiles in the Canadian standardization sample.

    Science.gov (United States)

    Lange, Rael T

    2007-01-01

    Representative index score profiles were examined in the Canadian standardization sample of the Wechsler Adult Intelligence Scale-Third Edition (WAIS-III). The identification of profile patterns was based on the methodology proposed by Lange, Iverson, Senior, and Chelune (2002) that aims to maximize the influence of profile shape and minimize the influence of profile magnitude on the cluster solution. A two-step cluster analysis procedure was used (i.e., hierarchical and k-means analyses). Cluster analysis of the four index scores (i.e., Verbal Comprehension [VCI], Perceptual Organization [POI], Working Memory [WMI], Processing Speed [PSI]) identified six profiles in this sample. Profiles were differentiated by pattern of performance and were primarily characterized as (a) high VCI/POI, low WMI/PSI, (b) low VCI/POI, high WMI/PSI, (c) high PSI, (d) low PSI, (e) high VCI/WMI, low POI/PSI, and (f) low VCI, high POI. These profiles are potentially useful for determining whether a patient's WAIS-III performance is unusual in a normal population.

  15. Validation of the in-flight calibration procedures for the MICROSCOPE space mission

    Science.gov (United States)

    Hardy, Émilie; Levy, Agnès; Rodrigues, Manuel; Touboul, Pierre; Métris, Gilles

    2013-11-01

    The MICROSCOPE space mission aims to test the Equivalence Principle with an accuracy of 10-15. The drag-free micro-satellite will orbit around the Earth and embark a differential electrostatic accelerometer including two cylindrical test masses submitted to the same gravitational field and made of different materials. The experience consists in testing the equality of the electrostatic acceleration applied to the masses to maintain them relatively motionless. The accuracy of the measurements exploited for the test of the Equivalence Principle is limited by our a priori knowledge of several physical parameters of the instrument. These parameters are partially estimated on-ground, but with an insufficient accuracy, and an in-orbit calibration is therefore required to correct the measurements. The calibration procedures have been defined and their analytical performances have been evaluated. In addition, a simulator software including the dynamics model of the instrument, the satellite drag-free system and the perturbing environment has been developed to numerically validate the analytical results. After an overall presentation of the MICROSCOPE mission, this paper will describe the calibration procedures and focus on the simulator. Such an in-flight calibration is mandatory for similar space missions taking advantage of a drag-free system.

  16. Simple laser vision sensor calibration for surface profiling applications

    Science.gov (United States)

    Abu-Nabah, Bassam A.; ElSoussi, Adnane O.; Al Alami, Abed ElRahman K.

    2016-09-01

    Due to the relatively large structures in the Oil and Gas industry, original equipment manufacturers (OEMs) have been implementing custom-designed laser vision sensor (LVS) surface profiling systems as part of quality control in their manufacturing processes. The rough manufacturing environment and the continuous movement and misalignment of these custom-designed tools adversely affect the accuracy of laser-based vision surface profiling applications. Accordingly, Oil and Gas businesses have been raising the demand from the OEMs to implement practical and robust LVS calibration techniques prior to running any visual inspections. This effort introduces an LVS calibration technique representing a simplified version of two known calibration techniques, which are commonly implemented to obtain a calibrated LVS system for surface profiling applications. Both calibration techniques are implemented virtually and experimentally to scan simulated and three-dimensional (3D) printed features of known profiles, respectively. Scanned data is transformed from the camera frame to points in the world coordinate system and compared with the input profiles to validate the introduced calibration technique capability against the more complex approach and preliminarily assess the measurement technique for weld profiling applications. Moreover, the sensitivity to stand-off distances is analyzed to illustrate the practicality of the presented technique.

  17. Propagation of measurement accuracy to biomass soft-sensor estimation and control quality.

    Science.gov (United States)

    Steinwandter, Valentin; Zahel, Thomas; Sagmeister, Patrick; Herwig, Christoph

    2017-01-01

    In biopharmaceutical process development and manufacturing, the online measurement of biomass and derived specific turnover rates is a central task to physiologically monitor and control the process. However, hard-type sensors such as dielectric spectroscopy, broth fluorescence, or permittivity measurement harbor various disadvantages. Therefore, soft-sensors, which use measurements of the off-gas stream and substrate feed to reconcile turnover rates and provide an online estimate of the biomass formation, are smart alternatives. For the reconciliation procedure, mass and energy balances are used together with accuracy estimations of measured conversion rates, which were so far arbitrarily chosen and static over the entire process. In this contribution, we present a novel strategy within the soft-sensor framework (named adaptive soft-sensor) to propagate uncertainties from measurements to conversion rates and demonstrate the benefits: For industrially relevant conditions, hereby the error of the resulting estimated biomass formation rate and specific substrate consumption rate could be decreased by 43 and 64 %, respectively, compared to traditional soft-sensor approaches. Moreover, we present a generic workflow to determine the required raw signal accuracy to obtain predefined accuracies of soft-sensor estimations. Thereby, appropriate measurement devices and maintenance intervals can be selected. Furthermore, using this workflow, we demonstrate that the estimation accuracy of the soft-sensor can be additionally and substantially increased.

  18. Modal-pushover-based ground-motion scaling procedure

    Science.gov (United States)

    Kalkan, Erol; Chopra, Anil K.

    2011-01-01

    Earthquake engineering is increasingly using nonlinear response history analysis (RHA) to demonstrate the performance of structures. This rigorous method of analysis requires selection and scaling of ground motions appropriate to design hazard levels. This paper presents a modal-pushover-based scaling (MPS) procedure to scale ground motions for use in a nonlinear RHA of buildings. In the MPS method, the ground motions are scaled to match to a specified tolerance, a target value of the inelastic deformation of the first-mode inelastic single-degree-of-freedom (SDF) system whose properties are determined by the first-mode pushover analysis. Appropriate for first-mode dominated structures, this approach is extended for structures with significant contributions of higher modes by considering elastic deformation of second-mode SDF systems in selecting a subset of the scaled ground motions. Based on results presented for three actual buildings-4, 6, and 13-story-the accuracy and efficiency of the MPS procedure are established and its superiority over the ASCE/SEI 7-05 scaling procedure is demonstrated.

  19. PIXE depth profiling using variation of detection angle

    International Nuclear Information System (INIS)

    Miranda, J.; Rickards, J.; Trejo-Luna, R.

    2006-01-01

    A method to apply particle induced X-ray emission (PIXE) for depth profiling, based on the variation of the X-ray detection angle, is proposed. The procedure uses X-ray yields normalized to those emitted at a particular reference angle. Application of the method to implanted samples and thin metallic films gave excellent results regarding the range of implanted ions and film thickness, respectively. However, there is no complete information about the width of the distribution of the implanted ions, emphasizing the need to develop a full mathematical algorithm to obtain the general depth profile

  20. Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Paprosky WG

    2016-11-01

    Full Text Available Wayne G Paprosky,1,2 Jeffrey M Muir3 1Department of Orthopedics, Section of Adult Joint Reconstruction, Department of Orthopedics, Rush University Medical Center, Rush–Presbyterian–St Luke’s Medical Center, Chicago, 2Central DuPage Hospital, Winfield, IL, USA; 3Intellijoint Surgical, Inc, Waterloo, ON, Canada Abstract: Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term consequences such as pain, instability, neurological deficits, dislocation, and revision surgery, as well as patient dissatisfaction and, increasingly, litigation. Current methods of managing these parameters are limited, with manual methods such as outriggers or calipers being used to monitor leg length; however, these are susceptible to small intraoperative changes in patient position and are therefore inaccurate. Computer-assisted navigation, while offering improved accuracy, is expensive and cumbersome, in addition to adding significantly to procedural time. To address the technological gap in hip arthroplasty, a new intraoperative navigation tool (Intellijoint HIP® has been developed. This innovative, 3D mini-optical navigation tool provides real-time, intraoperative data on leg length, offset, and cup position and allows for improved accuracy and precision in component selection and alignment. Benchtop and simulated clinical use testing have demonstrated excellent accuracy, with the navigation tool able to measure leg length and offset to within <1 mm and cup position to within <1° in both anteversion and inclination. This study describes the indications, procedural technique, and early accuracy results of the Intellijoint HIP

  1. A Modified Catheterization Procedure to Reduce Bladder Damage when Collecting Urine Samples from Holstein Cows

    Science.gov (United States)

    TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto

    2014-01-01

    ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376

  2. Sea wind parameters retrieval using Y-configured Doppler navigation system data. Performance and accuracy

    Science.gov (United States)

    Khachaturian, A. B.; Nekrasov, A. V.; Bogachev, M. I.

    2018-05-01

    The authors report the results of the computer simulations of the performance and accuracy of the sea wind speed and direction retrieval. The analyzed measurements over the sea surface are made by the airborne microwave Doppler navigation system (DNS) with three Y-configured beams operated as a scatterometer enhancing its functionality. Single- and double-stage wind measurement procedures are proposed and recommendations for their implementation are described.

  3. Accuracy of impressions with different impression materials in angulated implants.

    Science.gov (United States)

    Reddy, S; Prasad, K; Vakil, H; Jain, A; Chowdhary, R

    2013-01-01

    To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were placed parallel to each other and perpendicular to the plane of the cast. In the second and third group (control), all three implants were placed at 10° and 15 o angulation respectively to the long axis of the cast, tilting towards the centre. Impressions were made with polyvinyl siloxane and polyether impression materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts. Three reference distances were evaluated on each test cast by using a profile projector and compared with control groups to determine the effect of combined interaction of implant angulation and impression materials on the accuracy of implant resultant cast. Statistical analysis revealed no significant difference in dimensional accuracy of the resultant casts made from two different impression materials (polyvinyl siloxane and polyether) by closed tray impression technique in parallel and angulated implants. On the basis of the results of this study, the use of both the impression materials i.e., polyether and polyvinyl siloxane impression is recommended for impression making in parallel as well as angulated implants.

  4. Accuracy of computer-assisted orthognathic surgery.

    Science.gov (United States)

    De Riu, Giacomo; Virdis, Paola Ilaria; Meloni, Silvio Mario; Lumbau, Aurea; Vaira, Luigi Angelo

    2018-02-01

    The purpose of this study was to retrospectively evaluate the difference between the planned and the actual movements of the jaws, using three-dimensional (3D) software for PC-assisted orthognathic surgery, to establish the accuracy of the procedure. A retrospective study was performed with 49 patients who had undergone PC-guided bimaxillary surgery. The accuracy of the protocol was determined by comparing planned movements of the jaws with the actual surgical movements, analysing frontal and lateral cephalometries. The overall results were deemed accurate, and differences among 12 of the 15 parameters were considered nonsignificant. Significant differences were reported for SNA (p = 0.008), SNB (p = 0.006), and anterior facial height (p = 0.033). The latter was significantly different in patients who had undergone genioplasty when compared with patients who had not. Virtual surgical planning presented a good degree of accuracy for most of the parameters assessed, with an average error of 1.98 mm for linear measures and 1.19° for angular measures. In general, a tendency towards under-projection in jaws was detected, probably due to imperfect condylar seating. A slight overcorrection of SNA and SNB during virtual planning (approximately 2°) could be beneficial. Further progress is required in the development of 3D simulation of the soft tissue, which currently does not allow an accurate management of the facial height and the chin position. Virtual planning cannot replace the need for constant intraoperative monitoring of the jaws' movements and real-time comparisons between planned and actual outcomes. It is therefore appropriate to leave some margin for correction of inaccuracies in the virtual planning. In this sense, it may be appropriate to use only the intermediate splint, and then use the planned occlusion and clinical measurements to guide repositioning of the second jaw and chin, respectively. Copyright © 2017 European Association for Cranio

  5. Cognitive Styles in Admission Procedures for Assessing Candidates of Architecture

    Science.gov (United States)

    Casakin, Hernan; Gigi, Ariela

    2016-01-01

    Cognitive style has a strong predictive power in academic and professional success. This study investigated the cognitive profile of candidates studying architecture. Specifically, it explored the relation between visual and verbal cognitive styles, and the performance of candidates in admission procedures. The cognitive styles of candidates who…

  6. 201Tl-SPECT in low-grade gliomas: diagnostic accuracy in differential diagnosis between tumour recurrence and radionecrosis

    International Nuclear Information System (INIS)

    Gomez-Rio, Manuel; Martinez del Valle Torres, Dolores; Rodriguez-Fernandez, Antonio; Llamas-Elvira, Jose Manuel; Lozano, Simeon Ortega; Font, Carlos Ramos; Lopez Ramirez, Escarlata; Katati, Majed

    2004-01-01

    The aim of this work was to describe the usefulness of a simple 201 Tl single-photon emission computed tomography (SPECT) technique in the differential diagnosis between tumour recurrence and radionecrosis during the follow-up of patients treated for low-grade gliomas. The study population comprised 84 patients treated for low-grade gliomas who showed suspicion of tumour recurrence during their follow-up. All patients were examined by neuro-anatomical imaging procedures (CT, MRI) and 201 Tl-SPECT. 201 Tl-SPECT images were assessed by visual analysis based only on the information on the prescription form and by estimation of the uptake index (ratio of mean counts in the lesion to those in the contralateral mirror area). Examiners were blinded to the results of other tests. Under these conditions, the neuro-anatomical procedures yielded 26.2% inconclusive reports, with a global diagnostic accuracy of 0.61, a sensitivity of 0.63 and a specificity of 0.59. The global diagnostic accuracy for 201 Tl-SPECT was 0.83, with a sensitivity of 0.88 and a specificity of 0.76. Diagnostic pitfalls were observed in regions with physiological 201 Tl uptake, i.e. the posterior cranial fossa, diencephalon, lateral ventricles and cavernous and longitudinal venous sinuses. An uptake index cut-off value of 1.25 showed a sensitivity of 0.90 and specificity of 0.80 for detection of tumour activity. 201 Tl-SPECT has adequate diagnostic accuracy to be part of routine algorithms in the follow-up of patients with low-grade glioma suspected of tumour recurrence, as an alternative to neuro-anatomical procedures and not solely as a complementary test. (orig.)

  7. Self-Judgments of Word Production Accuracy in Acquired Apraxia of Speech.

    Science.gov (United States)

    Wambaugh, Julie; Shuster, Linda; Bailey, Dallin J; Mauszycki, Shannon; Kean, Jacob; Nessler, Christina; Wright, Sandra; Brunsvold, Jessica

    2016-12-01

    The ability to recognize one's own speech errors has long been considered a clinical feature of acquired apraxia of speech (AOS) despite limited empirical data supporting this notion. This study was designed to (a) investigate the ability of speakers with AOS to self-judge the accuracy of their own word productions and (b) examine the test-retest stability of a measure to quantify the self-judgments of speakers with AOS. Twenty-four speakers with AOS and aphasia repeated mono- and multisyllabic words. After each word, they indicated whether their production was correct or incorrect. This procedure was repeated 1 week later to examine performance stability. Percentage of incorrect word productions was stable for the group across times. Accuracy of judgments ranged from 64% to 100% at Time 1 and from 56% to 100% at Time 2. Inaccurate judgments of error productions (false positives) occurred much more frequently than inaccurate judgments of correct productions (false negatives). Error production was remarkably stable in our participants. As a group, the participants failed to detect almost one third of words produced erroneously. However, accuracy and stability of judgments over sampling times varied across participants. Findings suggest that error awareness might be a worthwhile target for treatment in some individuals with AOS.

  8. CT-guided procedures: evaluation of a phantom system to teach accurate needle placement

    International Nuclear Information System (INIS)

    Dimmick, S.; Jones, M.; Challen, J.; Iedema, J.; Wattuhewa, U.; Coucher, J.

    2007-01-01

    Aim: To evaluate the use of a phantom system to help teach the basic techniques of accurate CT-guided needle placement, thereby avoiding the risks associated with teaching on patients. Materials and Methods: Gelatine phantoms with five, 1.9 cm embedded spherical wooden targets were constructed. Four trainee operators performed 15 simulated biopsy procedures on the targets (series one) and repeated identical procedures 2 weeks later (series two). Statistical analysis of accuracy of needle placement and subject confidence were performed. Results: Significant sequential improvement in axial plane angular error was noted with the average error decreasing by 0.33 degrees after every five procedures performed (95% CI: -0.58 to -0.08, p = 0.01). Operator confidence indicated significant improvement both within each series and from series one to series two (95% CI: 0.08 to 1.17, p = 0.025 and 95% CI: 0.00 to 0.58, p = 0.05) respectively. However, variability in operator performance made statistically significant improvement in other variables unproven. Conclusion: Despite the study comprising a relatively small number of participants and procedures, it clearly demonstrated the effectiveness of teaching operators to perform CT-guided procedures using a phantom system. Needle placement accuracy significantly improved, with a reduction in axial angular error, and improved operator confidence without the risks associated with training on patients. Three of the operators in this study had never performed a CT-guided procedure previously, and their proficiency, after a relatively short but intense period of training, was impressive. The use of phantoms should be considered routinely for basic training of CT-guided needle placement

  9. A two-dimensional regularization algorithm for density profile evaluation from broadband reflectometry

    International Nuclear Information System (INIS)

    Nunes, F.; Varela, P.; Silva, A.; Manso, M.; Santos, J.; Nunes, I.; Serra, F.; Kurzan, B.; Suttrop, W.

    1997-01-01

    Broadband reflectometry is a current technique that uses the round-trip group delays of reflected frequency-swept waves to measure density profiles of fusion plasmas. The main factor that may limit the accuracy of the reconstructed profiles is the interference of the probing waves with the plasma density fluctuations: plasma turbulence leads to random phase variations and magneto hydrodynamic activity produces mainly strong amplitude and phase modulations. Both effects cause the decrease, and eventually loss, of signal at some frequencies. Several data processing techniques can be applied to filter and/or interpolate noisy group delay data obtained from turbulent plasmas with a single frequency sweep. Here, we propose a more powerful algorithm performing two-dimensional regularization (in space and time) of data provided by multiple consecutive frequency sweeps, which leads to density profiles with improved accuracy. The new method is described and its application to simulated data corrupted by noise and missing data is considered. It is shown that the algorithm improves the identification of slowly varying plasma density perturbations by attenuating the effect of fast fluctuations and noise contained in experimental data. First results obtained with this method in ASDEX Upgrade tokamak are presented. copyright 1997 American Institute of Physics

  10. Meditation experience predicts introspective accuracy.

    Directory of Open Access Journals (Sweden)

    Kieran C R Fox

    Full Text Available The accuracy of subjective reports, especially those involving introspection of one's own internal processes, remains unclear, and research has demonstrated large individual differences in introspective accuracy. It has been hypothesized that introspective accuracy may be heightened in persons who engage in meditation practices, due to the highly introspective nature of such practices. We undertook a preliminary exploration of this hypothesis, examining introspective accuracy in a cross-section of meditation practitioners (1-15,000 hrs experience. Introspective accuracy was assessed by comparing subjective reports of tactile sensitivity for each of 20 body regions during a 'body-scanning' meditation with averaged, objective measures of tactile sensitivity (mean size of body representation area in primary somatosensory cortex; two-point discrimination threshold as reported in prior research. Expert meditators showed significantly better introspective accuracy than novices; overall meditation experience also significantly predicted individual introspective accuracy. These results suggest that long-term meditators provide more accurate introspective reports than novices.

  11. Precision and accuracy, two steps towards the standardization of XRPD measurements

    International Nuclear Information System (INIS)

    Berti, G.

    1996-01-01

    Any standardization process requires to get at results comprehensible, reproducible and traceable. Precision and accuracy of the measurements play a key role in getting at these requirements. The adoption of either physical (standard) or mathematical models allows for describing the whole diffraction measurement process with the necessary physical significance. From an other hand, the adoption of procedure, which are capable of controlling the measurement process, renders it reproducible and traceable. The falling of those requirements make difficult to transfer or replicate elsewhere experiences which may give even excellent result in a given laboratory

  12. Precision and accuracy, two steps towards the standardization of XRPD measurements

    Energy Technology Data Exchange (ETDEWEB)

    Berti, G [Pisa Univ. (Italy). Dept. of Earth Sciences

    1996-09-01

    Any standardization process requires to get at results comprehensible, reproducible and traceable. Precision and accuracy of the measurements play a key role in getting at these requirements. The adoption of either physical (standard) or mathematical models allows for describing the whole diffraction measurement process with the necessary physical significance. From an other hand, the adoption of procedure, which are capable of controlling the measurement process, renders it reproducible and traceable. The falling of those requirements make difficult to transfer or replicate elsewhere experiences which may give even excellent result in a given laboratory.

  13. A study for high accuracy measurement of residual stress by deep hole drilling technique

    Science.gov (United States)

    Kitano, Houichi; Okano, Shigetaka; Mochizuki, Masahito

    2012-08-01

    The deep hole drilling technique (DHD) received much attention in recent years as a method for measuring through-thickness residual stresses. However, some accuracy problems occur when residual stress evaluation is performed by the DHD technique. One of the reasons is that the traditional DHD evaluation formula applies to the plane stress condition. The second is that the effects of the plastic deformation produced in the drilling process and the deformation produced in the trepanning process are ignored. In this study, a modified evaluation formula, which is applied to the plane strain condition, is proposed. In addition, a new procedure is proposed which can consider the effects of the deformation produced in the DHD process by investigating the effects in detail by finite element (FE) analysis. Then, the evaluation results obtained by the new procedure are compared with that obtained by traditional DHD procedure by FE analysis. As a result, the new procedure evaluates the residual stress fields better than the traditional DHD procedure when the measuring object is thick enough that the stress condition can be assumed as the plane strain condition as in the model used in this study.

  14. The accuracy of webcams in 2D motion analysis: sources of error and their control

    International Nuclear Information System (INIS)

    Page, A; Candelas, P; Belmar, F; Moreno, R

    2008-01-01

    In this paper, we show the potential of webcams as precision measuring instruments in a physics laboratory. Various sources of error appearing in 2D coordinate measurements using low-cost commercial webcams are discussed, quantifying their impact on accuracy and precision, and simple procedures to control these sources of error are presented. Finally, an experiment with controlled movement is performed to experimentally measure the errors described above and to assess the effectiveness of the proposed corrective measures. It will be shown that when these aspects are considered, it is possible to obtain errors lower than 0.1%. This level of accuracy demonstrates that webcams should be considered as very precise and accurate measuring instruments at a remarkably low cost

  15. The accuracy of webcams in 2D motion analysis: sources of error and their control

    Energy Technology Data Exchange (ETDEWEB)

    Page, A; Candelas, P; Belmar, F [Departamento de Fisica Aplicada, Universidad Politecnica de Valencia, Valencia (Spain); Moreno, R [Instituto de Biomecanica de Valencia, Valencia (Spain)], E-mail: alvaro.page@ibv.upv.es

    2008-07-15

    In this paper, we show the potential of webcams as precision measuring instruments in a physics laboratory. Various sources of error appearing in 2D coordinate measurements using low-cost commercial webcams are discussed, quantifying their impact on accuracy and precision, and simple procedures to control these sources of error are presented. Finally, an experiment with controlled movement is performed to experimentally measure the errors described above and to assess the effectiveness of the proposed corrective measures. It will be shown that when these aspects are considered, it is possible to obtain errors lower than 0.1%. This level of accuracy demonstrates that webcams should be considered as very precise and accurate measuring instruments at a remarkably low cost.

  16. Performance comparison of digital microRNA profiling technologies applied on human breast cancer cell lines.

    Directory of Open Access Journals (Sweden)

    Erik Knutsen

    Full Text Available MicroRNA profiling represents an important first-step in deducting individual RNA-based regulatory function in a cell, tissue, or at a specific developmental stage. Currently there are several different platforms to choose from in order to make the initial miRNA profiles. In this study we investigate recently developed digital microRNA high-throughput technologies. Four different platforms were compared including next generation SOLiD ligation sequencing and Illumina HiSeq sequencing, hybridization-based NanoString nCounter, and miRCURY locked nucleic acid RT-qPCR. For all four technologies, full microRNA profiles were generated from human cell lines that represent noninvasive and invasive tumorigenic breast cancer. This study reports the correlation between platforms, as well as a more extensive analysis of the accuracy and sensitivity of data generated when using different platforms and important consideration when verifying results by the use of additional technologies. We found all the platforms to be highly capable for microRNA analysis. Furthermore, the two NGS platforms and RT-qPCR all have equally high sensitivity, and the fold change accuracy is independent of individual miRNA concentration for NGS and RT-qPCR. Based on these findings we propose new guidelines and considerations when performing microRNA profiling.

  17. Modeling of welded bead profile for rapid prototyping by robotic MAG welding

    Institute of Scientific and Technical Information of China (English)

    CAO Yong; ZHU Sheng; WANG Tao; WANG Wanglong

    2009-01-01

    As a deposition technology, robotic metal active gas(MAG) welding has shown new promise for rapid prototyping (RP) of metallic parts. During the process of metal forming using robotic MAG welding, sectional profile of single-pass welded bead is critical to formed accuracy and quality of metal pans. In this paper, the experiments of single-pass welded bead for rapid prototyping using robotic MAG welding were carried out. The effect of some edge detectors on the cross-sectional edge of welded bead was discussed and curve fitting was applied using leat square fitting. Consequently, the mathematical model of welded bead profile was developed. The experimental results show that good shape could be obtained under suitable welding parameters. Canny operawr is suitable to edge detection of welded bead profile, and the mathematical model of welded bead profile developed is approximately parabola.

  18. High-accuracy drilling with an image guided light weight robot: autonomous versus intuitive feed control.

    Science.gov (United States)

    Tauscher, Sebastian; Fuchs, Alexander; Baier, Fabian; Kahrs, Lüder A; Ortmaier, Tobias

    2017-10-01

    Assistance of robotic systems in the operating room promises higher accuracy and, hence, demanding surgical interventions become realisable (e.g. the direct cochlear access). Additionally, an intuitive user interface is crucial for the use of robots in surgery. Torque sensors in the joints can be employed for intuitive interaction concepts. Regarding the accuracy, they lead to a lower structural stiffness and, thus, to an additional error source. The aim of this contribution is to examine, if an accuracy needed for demanding interventions can be achieved by such a system or not. Feasible accuracy results of the robot-assisted process depend on each work-flow step. This work focuses on the determination of the tool coordinate frame. A method for drill axis definition is implemented and analysed. Furthermore, a concept of admittance feed control is developed. This allows the user to control feeding along the planned path by applying a force to the robots structure. The accuracy is researched by drilling experiments with a PMMA phantom and artificial bone blocks. The described drill axis estimation process results in a high angular repeatability ([Formula: see text]). In the first set of drilling results, an accuracy of [Formula: see text] at entrance and [Formula: see text] at target point excluding imaging was achieved. With admittance feed control an accuracy of [Formula: see text] at target point was realised. In a third set twelve holes were drilled in artificial temporal bone phantoms including imaging. In this set-up an error of [Formula: see text] and [Formula: see text] was achieved. The results of conducted experiments show that accuracy requirements for demanding procedures such as the direct cochlear access can be fulfilled with compliant systems. Furthermore, it was shown that with the presented admittance feed control an accuracy of less then [Formula: see text] is achievable.

  19. Overlay accuracy fundamentals

    Science.gov (United States)

    Kandel, Daniel; Levinski, Vladimir; Sapiens, Noam; Cohen, Guy; Amit, Eran; Klein, Dana; Vakshtein, Irina

    2012-03-01

    Currently, the performance of overlay metrology is evaluated mainly based on random error contributions such as precision and TIS variability. With the expected shrinkage of the overlay metrology budget to DBO (1st order diffraction based overlay). It is demonstrated that the sensitivity of DBO to overlay mark asymmetry is larger than the sensitivity of imaging overlay. Finally, we show that a recently developed measurement quality metric serves as a valuable tool for improving overlay metrology accuracy. Simulation results demonstrate that the accuracy of imaging overlay can be improved significantly by recipe setup optimized using the quality metric. We conclude that imaging overlay metrology, complemented by appropriate use of measurement quality metric, results in optimal overlay accuracy.

  20. Design of intermediate die shape of multistage profile drawing for linear motion guide

    International Nuclear Information System (INIS)

    Lee, Sang Kon; Lee, Jae Eun; Kim, Sung Min; Kim, Byung Min

    2010-01-01

    The design of an intermediate die shape is very important in multistage profile drawing. In this study, two design methods for the intermediate die shape of a multistage profile drawing for producing a linear motion guide (LM) guide is proposed. One is the electric field analysis method using the equipotential lines generated by electric field analysis, and the other is the virtual die method using a virtual drawing die constructed from the initial material and the final product shape. In order to design the intermediate die shapes of a multistage profile drawing for producing LM guide, the proposed design methods are applied, and then FE analysis and profile drawing experiment are performed. As a result, based on the measurement of dimensional accuracy, it can be known that the intermediate die shape can be designed effectively

  1. Aerosol characteristics inversion based on the improved lidar ratio profile with the ground-based rotational Raman-Mie lidar

    Science.gov (United States)

    Ji, Hongzhu; Zhang, Yinchao; Chen, Siying; Chen, He; Guo, Pan

    2018-06-01

    An iterative method, based on a derived inverse relationship between atmospheric backscatter coefficient and aerosol lidar ratio, is proposed to invert the lidar ratio profile and aerosol extinction coefficient. The feasibility of this method is investigated theoretically and experimentally. Simulation results show the inversion accuracy of aerosol optical properties for iterative method can be improved in the near-surface aerosol layer and the optical thick layer. Experimentally, as a result of the reduced insufficiency error and incoherence error, the aerosol optical properties with higher accuracy can be obtained in the near-surface region and the region of numerical derivative distortion. In addition, the particle component can be distinguished roughly based on this improved lidar ratio profile.

  2. Full area covered 3D profile measurement of special-shaped optics based on a new prototype non-contact profiler.

    Science.gov (United States)

    Du, Hui-Lin; Zhou, Zhao-Zhong; Sun, Ze-Qing; Ju, Bing-Feng; Xu, Shaoning; Sun, Anyu

    2017-06-01

    A new prototype non-contact profiler based on surface tracking has been specially developed. Surface tracking is carried out by a specially designed dual stage probe system with the aid of a four-Degree Of Freedom high-precision motion platform. The dual stage probe system keeps a short-range optical probe constantly tracking the surface by a self-developed voice coil motor servo, by which a wide measuring range of up to 10 mm is realized. The system performance evaluation including resolution, repeatability, and scanning speed proved the good capability of the new prototype non-contact profiler. To realize a full area covered 3D profile measurement of special-shaped optics within one scanning procedure, a signal intensity monitor integrated in the surface tracking controller is specially developed. In the experiment, a snip-single-corner-rectangular-shaped freeform surface was successfully measured over full area by the new non-contact profiler. This work provides an effective solution for 3D profile measurement of special-shaped optical surfaces over full reflecting area. Experimental results demonstrate that the proposed measuring system is of great significance in quality evaluation of optical surfaces.

  3. Creating a soil-like profile for plant growth using tailings sand and fine tails

    International Nuclear Information System (INIS)

    Li, X.; Fung, M. P. Y.

    1996-01-01

    Development of a technology to create stable aggregates with a soil-like profile capable of supporting a stable plant community, was discussed as the major challenge and primary task in restoring oil sands processing wastes, and in re-creating a self-sustaining ecosystem. A procedure for creating a soil-like profile using oil sands mining wastes, was described. Clay and water content were critical factors in the aggregation procedure. A study to evaluate the physical, chemical and biological properties of these soils and their suitability as a plant growth medium is currently underway. 6 refs., 3 figs

  4. Ion transition heights from topside electron density profiles

    International Nuclear Information System (INIS)

    Titheridge, J.E.

    1976-01-01

    Theoretical electron density profiles are calculated for the topside ionosphere to determine the major factors controlling the profile shape. Only the mean temperature, the vertical temperature gradient and the O + /H + ion transition height are important. Vertical proton fluxes alter the ion transition height but have no other effect on the profile shape. Diffusive equilibrium profiles including only these three effects fit observed profiles, at all latitudes, to within experimental accuracy. Values of plasma temperature, temperature gradient and ion transition height hsub(T) were determined by fitting theoretical models to 60,000 experimental profiles obtained from Alouette 1 ionograms, at latitudes of 75 0 S to 85 0 N near solar minimum. Inside the plasmasphere hsub(T) varies from about 500 km on winter nights to 850 km on summer days. Diurnal variations are caused primarily by the production and loss of O + in the ionosphere. The approximately constant winter night value of hsub(T) is close to the level for chemical equilibrium. In summer hsub(T) is always above the equilibrium level, giving a continual production of protons which travel along lines of force to aid in maintaining the conjugate winter night ionosphere. Outside the plasmasphere hsub(T) is 300 to 600 km above the equilibrium level at all times. This implies a continual near-limiting upwards flux of protons which persists down to latitudes of about 60 0 at night and 50 0 during the day. (author)

  5. Quantifying TOLNet Ozone Lidar Accuracy During the 2014 DISCOVER-AQ and FRAPPE Campaigns

    Science.gov (United States)

    Wang, Lihua; Newchurch, Michael J.; Alvarez, Raul J., II; Berkoff, Timothy A.; Brown, Steven S.; Carrion, William; De Young, Russell J.; Johnson, Bryan J.; Ganoe, Rene; Gronoff, Guillaume; hide

    2017-01-01

    The Tropospheric Ozone Lidar Network (TOLNet) is a unique network of lidar systems that measure high-resolution atmospheric profiles of ozone. The accurate characterization of these lidars is necessary to determine the uniformity of the network calibration. From July to August 2014, three lidars, the TROPospheric OZone (TROPOZ) lidar, the Tunable Optical Profiler for Aerosol and oZone (TOPAZ) lidar, and the Langley Mobile Ozone Lidar (LMOL), of TOLNet participated in the Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) mission and the Front Range Air Pollution and Photochemistry Experiment (FRAPPA) to measure ozone variations from the boundary layer to the top of the troposphere. This study presents the analysis of the intercomparison between the TROPOZ, TOPAZ, and LMOL lidars, along with comparisons between the lidars and other in situ ozone instruments including ozonesondes and a P-3B airborne chemiluminescence sensor. The TOLNet lidars measured vertical ozone structures with an accuracy generally better than +/-15 % within the troposphere. Larger differences occur at some individual altitudes in both the near-field and far-field range of the lidar systems, largely as expected. In terms of column average, the TOLNet lidars measured ozone with an accuracy better than +/-5 % for both the intercomparison between the lidars and between the lidars and other instruments. These results indicate that these three TOLNet lidars are suitable for use in air quality, satellite validation, and ozone modeling efforts.

  6. Atmospheric profiles from active space-based radio measurements

    Science.gov (United States)

    Hardy, Kenneth R.; Hinson, David P.; Tyler, G. L.; Kursinski, E. R.

    1992-01-01

    The paper describes determinations of atmospheric profiles from space-based radio measurements and the retrieval methodology used, with special attention given to the measurement procedure and the characteristics of the soundings. It is speculated that reliable profiles of the terrestrial atmosphere can be obtained by the occultation technique from the surface to a height of about 60 km. With the full complement of 21 the Global Positioning System (GPS) satellites and one GPS receiver in sun synchronous polar orbit, a maximum of 42 soundings could be obtained for each complete orbit or about 670 per day, providing almost uniform global coverage.

  7. Seismic profile analysis of the Kangra and Dehradun re-entrant of ...

    Indian Academy of Sciences (India)

    Joyjit Dey

    2017-08-31

    Aug 31, 2017 ... These procedures lack direct quantitative measurement on the seismic profile required for subsurface structural architecture. ... knowledge of intricate structural architecture in ...... 4 32–42 (in Chinese with English abstract).

  8. A simple procedure for measuring pharyngeal sensitivity: a contribution to the diagnosis of sleep apnoea

    OpenAIRE

    Dematteis, M; Levy, P; Pepin, J

    2005-01-01

    Background: Patients with severe apnoea may have an impaired pharyngeal dilating reflex related to decreased pharyngeal sensitivity. The accuracy of a simple new procedure to measure pharyngeal sensitivity and to diagnose sleep disordered breathing (SDB) was investigated.

  9. Perception of Business People on the Evolution of the Accountant Profile

    Directory of Open Access Journals (Sweden)

    Gisele Cristina Plachi Virtuoso

    2018-04-01

    Full Text Available The objective of this work was to analyse the perception of business people on the evolution of the Accountant profile, considering the significant increase of it´s importance with the advent of international accounting standards. Therefore the following question was elaborated: what the perception of business people on the evolution of the Accountant profile? As for the methodological procedures, this study is classified as quantitative according to the approach, descriptive regarding the objectives and as a survey of the procedures. The data collection was done through the questionary containing eighteen closed questions and validated by three teachers in the area. A universe of 62 entrepreneurs, clients of an accounting office in the city of São José, state of Santa Catarina, was searched by e-mail, created through the tool google forms, and a sample of 53 (fifty three respondents, representing 85% of the population surveyed. The main results pointed that the business people perceive this evolution in the accounting professional profile, consider he essential for the business and would keep the accounting writing if they were not obliged. However, international accounting standards were not considered influential in the evolution of the Accountant profile and there are limitations on the use of their competences by business people.

  10. Application of Depth-Averaged Velocity Profile for Estimation of Longitudinal Dispersion in Rivers

    Directory of Open Access Journals (Sweden)

    Mohammad Givehchi

    2010-01-01

    Full Text Available River bed profiles and depth-averaged velocities are used as basic data in empirical and analytical equations for estimating the longitudinal dispersion coefficient which has always been a topic of great interest for researchers. The simple model proposed by Maghrebi is capable of predicting the normalized isovel contours in the cross section of rivers and channels as well as the depth-averaged velocity profiles. The required data in Maghrebi’s model are bed profile, shear stress, and roughness distributions. Comparison of depth-averaged velocities and longitudinal dispersion coefficients observed in the field data and those predicted by Maghrebi’s model revealed that Maghrebi’s model had an acceptable accuracy in predicting depth-averaged velocity.

  11. One process is not enough! A speed-accuracy tradeoff study of recognition memory.

    Science.gov (United States)

    Boldini, Angela; Russo, Riccardo; Avons, S E

    2004-04-01

    Speed-accuracy tradeoff (SAT) methods have been used to contrast single- and dual-process accounts of recognition memory. In these procedures, subjects are presented with individual test items and are required to make recognition decisions under various time constraints. In this experiment, we presented word lists under incidental learning conditions, varying the modality of presentation and level of processing. At test, we manipulated the interval between each visually presented test item and a response signal, thus controlling the amount of time available to retrieve target information. Study-test modality match had a beneficial effect on recognition accuracy at short response-signal delays (deep than from shallow processing at study only at relatively long response-signal delays (> or =300 msec). The results are congruent with views suggesting that both fast familiarity and slower recollection processes contribute to recognition memory.

  12. Sentinel lymph node procedure is highly accurate in squamous cell carcinoma of the vulva

    NARCIS (Netherlands)

    de Hullu, JA; Hollema, H; Piers, DA; Verheijen, RHM; van Diest, PJ; Mourits, MJE; Aalders, JG; van der Zee, AGJ

    Purpose: To determine the diagnostic accuracy of the sentinel lymph node procedure in patients with squamous cell carcinoma of the vulva and to investigate whether step sectioning and immunohistochemistry of sentinel lymph nodes increase the sensitivity for detection of metastases. Patients and

  13. An automatic optimum number of well-distributed ground control lines selection procedure based on genetic algorithm

    Science.gov (United States)

    Yavari, Somayeh; Valadan Zoej, Mohammad Javad; Salehi, Bahram

    2018-05-01

    The procedure of selecting an optimum number and best distribution of ground control information is important in order to reach accurate and robust registration results. This paper proposes a new general procedure based on Genetic Algorithm (GA) which is applicable for all kinds of features (point, line, and areal features). However, linear features due to their unique characteristics are of interest in this investigation. This method is called Optimum number of Well-Distributed ground control Information Selection (OWDIS) procedure. Using this method, a population of binary chromosomes is randomly initialized. The ones indicate the presence of a pair of conjugate lines as a GCL and zeros specify the absence. The chromosome length is considered equal to the number of all conjugate lines. For each chromosome, the unknown parameters of a proper mathematical model can be calculated using the selected GCLs (ones in each chromosome). Then, a limited number of Check Points (CPs) are used to evaluate the Root Mean Square Error (RMSE) of each chromosome as its fitness value. The procedure continues until reaching a stopping criterion. The number and position of ones in the best chromosome indicate the selected GCLs among all conjugate lines. To evaluate the proposed method, a GeoEye and an Ikonos Images are used over different areas of Iran. Comparing the obtained results by the proposed method in a traditional RFM with conventional methods that use all conjugate lines as GCLs shows five times the accuracy improvement (pixel level accuracy) as well as the strength of the proposed method. To prevent an over-parametrization error in a traditional RFM due to the selection of a high number of improper correlated terms, an optimized line-based RFM is also proposed. The results show the superiority of the combination of the proposed OWDIS method with an optimized line-based RFM in terms of increasing the accuracy to better than 0.7 pixel, reliability, and reducing systematic

  14. Accuracy and Sources of Error for an Angle Independent Volume Flow Estimator

    DEFF Research Database (Denmark)

    Jensen, Jonas; Olesen, Jacob Bjerring; Hansen, Peter Møller

    2014-01-01

    This paper investigates sources of error for a vector velocity volume flow estimator. Quantification of the estima tor’s accuracy is performed theoretically and investigated in vivo . Womersley’s model for pulsatile flow is used to simulate velo city profiles and calculate volume flow errors....... A BK Medical UltraView 800 ultrasound scanner with a 9 MHz linear array transducer is used to obtain Vector Flow Imaging sequences of a superficial part of the fistulas. Cross-sectional diameters of each fistu la are measured on B-mode images by rotating the scan plane 90 degrees. The major axis...

  15. NESmapper: accurate prediction of leucine-rich nuclear export signals using activity-based profiles.

    Directory of Open Access Journals (Sweden)

    Shunichi Kosugi

    2014-09-01

    Full Text Available The nuclear export of proteins is regulated largely through the exportin/CRM1 pathway, which involves the specific recognition of leucine-rich nuclear export signals (NESs in the cargo proteins, and modulates nuclear-cytoplasmic protein shuttling by antagonizing the nuclear import activity mediated by importins and the nuclear import signal (NLS. Although the prediction of NESs can help to define proteins that undergo regulated nuclear export, current methods of predicting NESs, including computational tools and consensus-sequence-based searches, have limited accuracy, especially in terms of their specificity. We found that each residue within an NES largely contributes independently and additively to the entire nuclear export activity. We created activity-based profiles of all classes of NESs with a comprehensive mutational analysis in mammalian cells. The profiles highlight a number of specific activity-affecting residues not only at the conserved hydrophobic positions but also in the linker and flanking regions. We then developed a computational tool, NESmapper, to predict NESs by using profiles that had been further optimized by training and combining the amino acid properties of the NES-flanking regions. This tool successfully reduced the considerable number of false positives, and the overall prediction accuracy was higher than that of other methods, including NESsential and Wregex. This profile-based prediction strategy is a reliable way to identify functional protein motifs. NESmapper is available at http://sourceforge.net/projects/nesmapper.

  16. High-accuracy measurement of ship velocities by DGPS; DGPS ni yoru sensoku keisoku no koseidoka ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, S; Koterayama, W [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1996-04-10

    The differential global positioning system (DGPS) can eliminate most of errors in ship velocity measurement by GPS positioning alone. Through two rounds of marine observations by towing an observation robot in summer 1995, the authors attempted high-accuracy measurement of ship velocities by DGPS, and also carried out both positioning by GPS alone and measurement using the bottom track of ADCP (acoustic Doppler current profiler). In this paper, the results obtained by these measurement methods were examined through comparison among them, and the accuracy of the measured ship velocities was considered. In DGPS measurement, both translocation method and interference positioning method were used. ADCP mounted on the observation robot allowed measurement of the velocity of current meter itself by its bottom track in shallow sea areas less than 350m. As the result of these marine observations, it was confirmed that the accuracy equivalent to that of direct measurement by bottom track is possible to be obtained by DGPS. 3 refs., 5 figs., 1 tab.

  17. EVALUATION OF A NOVEL UAV-BORNE TOPO-BATHYMETRIC LASER PROFILER

    Directory of Open Access Journals (Sweden)

    G. Mandlburger

    2016-06-01

    Full Text Available We present a novel topo-bathymetric laser profiler. The sensor system (RIEGL BathyCopter comprises a laser range finder, an Inertial Measurement Unit (IMU, a Global Navigation Satellite System (GNSS receiver, a control unit, and digital cameras mounted on an octocopter UAV (RiCOPTER. The range finder operates on the time-of-flight measurement principle and utilizes very short laser pulses (<1 ns in the green domain of the spectrum (λ=532 nm for measuring distances to both the water surface and the river bottom. For assessing the precision and accuracy of the system an experiment was carried out in October 2015 at a pre-alpine river (Pielach in Lower Austria. A 200 m longitudinal section and 12 river cross sections were measured with the BathyCopter sensor system at a flight altitude of 15-20 m above ground level and a measurement rate of 4 kHz. The 3D laser profiler points were compared with independent, quasi-simultaneous data acquisitions using (i the RIEGL VUX1-UAV lightweight topographic laser scanning system (bare earth, water surface and (ii terrestrial survey (river bed. Over bare earth the laser profiler heights have a std. dev. of 3 cm, the water surface height appears to be underestimated by 5 cm, and river bottom heights differ from the reference measurements by 10 cm with a std. dev. of 13 cm. When restricting the comparison to laser profiler bottom points and reference measurements with a lateral offset below 1 m, the values improve to 4 cm bias with a std. dev. of 6 cm. We report additionally on challenges in comparing UAV-borne to terrestrial profiles. Based on the accuracy and the small footprint (3.5 cm at the water surface we concluded that the acquired 3D points can potentially serve as input data (river bed geometry, grain roughness and validation data (water surface, water depth for hydrodynamic-numerical models.

  18. Evaluation of solution procedures for material and/or geometrically nonlinear structural analysis by the direct stiffness method.

    Science.gov (United States)

    Stricklin, J. A.; Haisler, W. E.; Von Riesemann, W. A.

    1972-01-01

    This paper presents an assessment of the solution procedures available for the analysis of inelastic and/or large deflection structural behavior. A literature survey is given which summarized the contribution of other researchers in the analysis of structural problems exhibiting material nonlinearities and combined geometric-material nonlinearities. Attention is focused at evaluating the available computation and solution techniques. Each of the solution techniques is developed from a common equation of equilibrium in terms of pseudo forces. The solution procedures are applied to circular plates and shells of revolution in an attempt to compare and evaluate each with respect to computational accuracy, economy, and efficiency. Based on the numerical studies, observations and comments are made with regard to the accuracy and economy of each solution technique.

  19. Soil moisture and temperature profile effects on microwave emission at low frequencies

    International Nuclear Information System (INIS)

    Raju, S.; Chanzy, A.; Wigneron, J.P.; Calvet, J.C.; Kerr, Y.; Laguerre, L.

    1995-01-01

    Soil moisture and temperature vertical profiles vary quickly during the day and may have a significant influence on the soil microwave emission. The objective of this work is to quantify such an influence and the consequences in soil moisture estimation from microwave radiometric information. The analysis is based on experimental data collected by the ground-based PORTOS radiometer at 1.4, 5.05, and 10.65 GHz and data simulated by a coherent model of microwave emission from layered media [Wilheit model (1978)]. In order to simulate diurnal variations of the brightness temperature (TB), the Wilheit model is coupled to a mechanistic model of heat and water flows in the soil. The Wilheit model is validated on experimental data and its performances for estimating TB are compared to those of a simpler approach based on a description of the soil media as a single layer (Fresnel model). When the depth of this single layer (hereafter referred to as the sampling depth) is determined to fit the experimental data, similar accuracy in TB estimation is found with both the Wilheit and Fresnel models. The soil microwave emission is found to be strongly affected by the diurnal variations of soil moisture and temperature profiles. Consequently, the TB sensitivity to soil moisture and temperature profiles has an influence on the estimation, from microwave observations, of the surface soil moisture in a surface layer with a fixed depth (05): the accuracy of θs retrievals and the optimal sampling depth depends both on the variation in soil moisture and temperature profile shape. (author)

  20. Design and implementation of the ITPA confinement profile database

    Energy Technology Data Exchange (ETDEWEB)

    Walters, Malcolm E-mail: malcolm.walters@ukaea.org.uk; Roach, Colin

    2004-06-01

    One key goal of the fusion program is to improve the accuracy of physics models in describing existing experiments, so as to make better predictions of the performance of future fusion devices. To support this goal, databases of experimental results from multiple machines have been assembled to facilitate the testing of physics models over a wide range of operating conditions and plasma parameters. One such database was the International Multi-Tokamak Profile Database. This database has more recently been substantially revamped to exploit newer technologies, and is now known as the ITPA confinement profile database http://www.tokamak-profiledb.ukaea.org.uk. The overall design of the updated system will be outlined and the implementation of the relational database part will be described in detail.

  1. High-accuracy 3-D modeling of cultural heritage: the digitizing of Donatello's "Maddalena".

    Science.gov (United States)

    Guidi, Gabriele; Beraldin, J Angelo; Atzeni, Carlo

    2004-03-01

    Three-dimensional digital modeling of Heritage works of art through optical scanners, has been demonstrated in recent years with results of exceptional interest. However, the routine application of three-dimensional (3-D) modeling to Heritage conservation still requires the systematic investigation of a number of technical problems. In this paper, the acquisition process of the 3-D digital model of the Maddalena by Donatello, a wooden statue representing one of the major masterpieces of the Italian Renaissance which was swept away by the Florence flood of 1966 and successively restored, is described. The paper reports all the steps of the acquisition procedure, from the project planning to the solution of the various problems due to range camera calibration and to material non optically cooperative. Since the scientific focus is centered on the 3-D model overall dimensional accuracy, a methodology for its quality control is described. Such control has demonstrated how, in some situations, the ICP-based alignment can lead to incorrect results. To circumvent this difficulty we propose an alignment technique based on the fusion of ICP with close-range digital photogrammetry and a non-invasive procedure in order to generate a final accurate model. In the end detailed results are presented, demonstrating the improvement of the final model, and how the proposed sensor fusion ensure a pre-specified level of accuracy.

  2. Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Baggu, Murali M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Smith, Kandler A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Friedl, Andrew [San Diego Gas and Electric; Bialek, Thomas [San Diego Gas and Electric; Schimpe, Michael Robert [Technical University of Munich

    2017-07-27

    A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.

  3. Ultrathin needle (25G) aspiration lung biopsy: diagnostic accuracy and complication rates

    International Nuclear Information System (INIS)

    Oikonomou, A.; Matzinger, F.R.; Seely, J.M.; Dennie, C.J.; Macleod, P.J.

    2004-01-01

    The aim of this study was to evaluate the diagnostic accuracy and complication rate of 25-G fine-needle aspiration biopsy (FNAB) of the lung in patients with suspected malignant focal lesions and abnormal lung function. The 25-G FNAB was performed in 123 patients who underwent prebiopsy CT and pulmonary function tests. Retrospective evaluation included pulmonary function, cytology, size of the lesion, depth of location, presence of emphysema on CT, needle passes, pneumothorax and drainage. The final diagnosis (gold standard) was based on histopathology after surgical resection or follow-up and response to treatment. Sixty-one patients had normal lung function or mild impairment (group 1) and 62 had moderate or severe impairment (group 2). Pneumothorax occurred in 26 of 126 procedures (20.6%) with drainage needed in 11 (8.7%). In group 2 pneumothorax occurred in 19 of 63 procedures (30.15%) with drainage needed in 11 (17.5%). The sensitivity, specificity and diagnostic accuracy of cytology results were 93.6, 100 and 94.4%, respectively. FEV1 (p=0.014), FEV1/FVC (p=0.005), FEF25-75 (p=0.001), DLCO (p=0.013) and presence of emphysema on CT (p<0.001) correlated with pneumothorax (Students t test). The 25-G lung FNAB is accurate and safe in diagnosing malignancy in patients with severe lung functional abnormality. Patients with moderate to severe airway obstruction have a higher prevalence of pneumothorax than patients with mild or no functional impairment

  4. Dimensional accuracy of 3D printed vertebra

    Science.gov (United States)

    Ogden, Kent; Ordway, Nathaniel; Diallo, Dalanda; Tillapaugh-Fay, Gwen; Aslan, Can

    2014-03-01

    3D printer applications in the biomedical sciences and medical imaging are expanding and will have an increasing impact on the practice of medicine. Orthopedic and reconstructive surgery has been an obvious area for development of 3D printer applications as the segmentation of bony anatomy to generate printable models is relatively straightforward. There are important issues that should be addressed when using 3D printed models for applications that may affect patient care; in particular the dimensional accuracy of the printed parts needs to be high to avoid poor decisions being made prior to surgery or therapeutic procedures. In this work, the dimensional accuracy of 3D printed vertebral bodies derived from CT data for a cadaver spine is compared with direct measurements on the ex-vivo vertebra and with measurements made on the 3D rendered vertebra using commercial 3D image processing software. The vertebra was printed on a consumer grade 3D printer using an additive print process using PLA (polylactic acid) filament. Measurements were made for 15 different anatomic features of the vertebral body, including vertebral body height, endplate width and depth, pedicle height and width, and spinal canal width and depth, among others. It is shown that for the segmentation and printing process used, the results of measurements made on the 3D printed vertebral body are substantially the same as those produced by direct measurement on the vertebra and measurements made on the 3D rendered vertebra.

  5. Bariatric Surgery and Endoluminal Procedures: IFSO Worldwide Survey 2014.

    Science.gov (United States)

    Angrisani, L; Santonicola, A; Iovino, P; Vitiello, A; Zundel, N; Buchwald, H; Scopinaro, N

    2017-09-01

    Several bariatric surgery worldwide surveys have been previously published to illustrate the evolution of bariatric surgery in the last decades. The aim of this survey is to report an updated overview of all bariatric procedures performed in 2014.For the first time, a special section on endoluminal techniques was added. The 2014 International Federation for the Surgery of Obesity and Metabolic Disorders (IFSO) survey form evaluating the number and the type of surgical and endoluminal bariatric procedures was emailed to all IFSO societies. Trend analyses from 2011 to 2014 were also performed. There were 56/60 (93.3%) responders. The total number of bariatric/metabolic procedures performed in 2014 consisted of 579,517 (97.6%) surgical operations and 14,725 (2.4%) endoluminal procedures. The most commonly performed procedure in the world was sleeve gastrectomy (SG) that reached 45.9%, followed by Roux-en-Y gastric bypass (RYGB) (39.6%), and adjustable gastric banding (AGB) (7.4%). The annual percentage changes from 2013 revealed the increase of SG and decrease of RYGB in all the IFSO regions (USA/Canada, Europe, and Asia/Pacific) with the exception of Latin/South America, where SG decreased and RYGB represented the most frequent procedure. There was a further increase in the total number of bariatric/metabolic procedures in 2014 and SG is currently the most frequent surgical procedure in the world. This is the first survey that describes the endoluminal procedures, but the accuracy of provided data should be hopefully improved in the next future. We encourage the creation of further national registries and their continuous updates taking into account all new bariatric procedures including the endoscopic procedures that will obtain increasing importance in the near future.

  6. Enhancing photogrammetric 3d city models with procedural modeling techniques for urban planning support

    International Nuclear Information System (INIS)

    Schubiger-Banz, S; Arisona, S M; Zhong, C

    2014-01-01

    This paper presents a workflow to increase the level of detail of reality-based 3D urban models. It combines the established workflows from photogrammetry and procedural modeling in order to exploit distinct advantages of both approaches. The combination has advantages over purely automatic acquisition in terms of visual quality, accuracy and model semantics. Compared to manual modeling, procedural techniques can be much more time effective while maintaining the qualitative properties of the modeled environment. In addition, our method includes processes for procedurally adding additional features such as road and rail networks. The resulting models meet the increasing needs in urban environments for planning, inventory, and analysis

  7. 100% classification accuracy considered harmful: the normalized information transfer factor explains the accuracy paradox.

    Directory of Open Access Journals (Sweden)

    Francisco J Valverde-Albacete

    Full Text Available The most widely spread measure of performance, accuracy, suffers from a paradox: predictive models with a given level of accuracy may have greater predictive power than models with higher accuracy. Despite optimizing classification error rate, high accuracy models may fail to capture crucial information transfer in the classification task. We present evidence of this behavior by means of a combinatorial analysis where every possible contingency matrix of 2, 3 and 4 classes classifiers are depicted on the entropy triangle, a more reliable information-theoretic tool for classification assessment. Motivated by this, we develop from first principles a measure of classification performance that takes into consideration the information learned by classifiers. We are then able to obtain the entropy-modulated accuracy (EMA, a pessimistic estimate of the expected accuracy with the influence of the input distribution factored out, and the normalized information transfer factor (NIT, a measure of how efficient is the transmission of information from the input to the output set of classes. The EMA is a more natural measure of classification performance than accuracy when the heuristic to maximize is the transfer of information through the classifier instead of classification error count. The NIT factor measures the effectiveness of the learning process in classifiers and also makes it harder for them to "cheat" using techniques like specialization, while also promoting the interpretability of results. Their use is demonstrated in a mind reading task competition that aims at decoding the identity of a video stimulus based on magnetoencephalography recordings. We show how the EMA and the NIT factor reject rankings based in accuracy, choosing more meaningful and interpretable classifiers.

  8. Emissions from laboratory combustion of wildland fuels: Emission factors and source profiles

    Science.gov (United States)

    L.-W. Anthony Chen; Hans Moosmuller; W. Patrick Arnott; Judith C. Chow; John G. Watson; Ronald A. Susott; Ronald E. Babbitt; Cyle E. Wold; Emily N. Lincoln; Wei Min Hao

    2007-01-01

    Combustion of wildland fuels represents a major source of particulate matter (PM) and light-absorbing elemental carbon (EC) on a national and global scale, but the emission factors and source profiles have not been well characterized with respect to different fuels and combustion phases. These uncertainties limit the accuracy of current emission inventories, smoke...

  9. Diagnosing Eyewitness Accuracy

    OpenAIRE

    Russ, Andrew

    2015-01-01

    Eyewitnesses frequently mistake innocent people for the perpetrator of an observed crime. Such misidentifications have led to the wrongful convictions of many people. Despite this, no reliable method yet exists to determine eyewitness accuracy. This thesis explored two new experimental methods for this purpose. Chapter 2 investigated whether repetition priming can measure prior exposure to a target and compared this with observers’ explicit eyewitness accuracy. Across three experiments slower...

  10. Aesthetic Surgical Procedures in Men: Major Complications and Associated Risk Factors.

    Science.gov (United States)

    Kaoutzanis, Christodoulos; Winocour, Julian; Yeslev, Max; Gupta, Varun; Asokan, Ishan; Roostaeian, Jason; Grotting, James C; Higdon, K Kye

    2018-03-14

    The number of men undergoing cosmetic surgery is increasing in North America. To determine the incidence and risk factors of major complications in males undergoing cosmetic surgery, compare the complication profiles between men and women, and identify specific procedures that are associated with higher risk of complications in males. A prospective cohort of patients undergoing cosmetic surgery between 2008 and 2013 was identified from the CosmetAssure database. Gender specific procedures were excluded. Primary outcome was occurrence of a major complication in males requiring emergency room visit, hospital admission, or reoperation within 30 days of the index operation. Univariate and multivariate analysis evaluated potential risk factors for major complications including age, body mass index (BMI), smoking, diabetes, type of surgical facility, type of procedure, and combined procedures. Of the 129,007 patients, 54,927 underwent gender nonspecific procedures, of which 5801 (10.6%) were males. Women showed a higher mean age (46.4 ± 14.1 vs 45.2 ± 16.7 years, P procedures (RR 3.47), and combined procedures (RR 2.56). Aesthetic surgery in men is safe with low major complication rates. Modifiable predictors of complications included BMI and combined procedures.

  11. Trait Perception Accuracy and Acquaintance Within Groups: Tracking Accuracy Development.

    Science.gov (United States)

    Brown, Jill A; Bernieri, Frank

    2017-05-01

    Previous work on trait perception has evaluated accuracy at discrete stages of relationships (e.g., strangers, best friends). A relatively limited body of literature has investigated changes in accuracy as acquaintance within a dyad or group increases. Small groups of initially unacquainted individuals spent more than 30 hr participating in a wide range of activities designed to represent common interpersonal contexts (e.g., eating, traveling). We calculated how accurately each participant judged others in their group on the big five traits across three distinct points within the acquaintance process: zero acquaintance, after a getting-to-know-you conversation, and after 10 weeks of interaction and activity. Judgments of all five traits exhibited accuracy above chance levels after 10 weeks. An examination of the trait rating stability revealed that much of the revision in judgments occurred not over the course of the 10-week relationship as suspected, but between zero acquaintance and the getting-to-know-you conversation.

  12. Determining the near-surface current profile from measurements of the wave dispersion relation

    Science.gov (United States)

    Smeltzer, Benjamin; Maxwell, Peter; Aesøy, Eirik; Ellingsen, Simen

    2017-11-01

    The current-induced Doppler shifts of waves can yield information about the background mean flow, providing an attractive method of inferring the current profile in the upper layer of the ocean. We present measurements of waves propagating on shear currents in a laboratory water channel, as well as theoretical investigations of inversion techniques for determining the vertical current structure. Spatial and temporal measurements of the free surface profile obtained using a synthetic Schlieren method are analyzed to determine the wave dispersion relation and Doppler shifts as a function of wavelength. The vertical current profile can then be inferred from the Doppler shifts using an inversion algorithm. Most existing algorithms rely on a priori assumptions of the shape of the current profile, and developing a method that uses less stringent assumptions is a focus of this study, allowing for measurement of more general current profiles. The accuracy of current inversion algorithms are evaluated by comparison to measurements of the mean flow profile from particle image velocimetry (PIV), and a discussion of the sensitivity to errors in the Doppler shifts is presented.

  13. CT-guided percutaneous transthoracic aspiration biopsy of lung lesions: factors influencing the diagnostic accuracy

    International Nuclear Information System (INIS)

    Huang Zhenguo; Zhang Xuezhe; Wang Wu

    2006-01-01

    Objective: To investigate the factors influencing the diagnostic accuracy in CT-guided percutaneous transthoracic aspiration biopsy of lung lesions. Methods: CT-guided percutaneous transthoracic biopsy was performed in 435 patients with surgical pathologic confirmation or clinical follow-up. Univariant statistical analysis and multivariant stepwise Logistic regression analysis were used to study the influence of lesion-related factors (benignancy or malignancy, size, location, depth, presence of cavity), procedure factors (laser-guidance, position of patient) and patient-related factors (sex, age, presence of emphysema); with the accuracy of the diagnosis. Results: 1)289 lesions were diagnosed as malignant ones and 146 as benign ones. The accuracy of CT-guided biopsy was 83.4%(363/435). Univariant analysis showed that the diagnostic accuracies for malignant and benign lesions were 88.9%(257/289) and 72.6%(106/146), respectively (χ 2 =18.71, P=0.00002). Laser-group was superior to non-laser group (88.4% versus 80.9%, respectively, χ 2 =4.00, P=0.0456). Mean diameters of lesions in correct diagnostic group and non-correct diagnostic group were 3.78±1.64 cm and 3.02±1.26 cm, respectively (F=13.79, P=0.0002). 2)Multivariant stepwise Logistic regression analysis showed that among the various factors influencing the final benign or malignant diagnoses (Wald χ 2 =14.01, P=0.0002) and using laser-guidance(Wald χ 2 =3.92, P=0.0477) were significantly associated with the diagnostic accuracy. Conclusions: Final correct diagnoses (benign, malignant) are closely related to the application of laser-guidance for determining the diagnostic accuracy in CT-guided transcutaneous thoracic needle aspiration biopsy. (authors)

  14. Configural and component processing in simultaneous and sequential lineup procedures

    OpenAIRE

    Flowe, HD; Smith, HMJ; Karoğlu, N; Onwuegbusi, TO; Rai, L

    2015-01-01

    Configural processing supports accurate face recognition, yet it has never been examined within the context of criminal identification lineups. We tested, using the inversion paradigm, the role of configural processing in lineups. Recent research has found that face discrimination accuracy in lineups is better in a simultaneous compared to a sequential lineup procedure. Therefore, we compared configural processing in simultaneous and sequential lineups to examine whether there are differences...

  15. Usefulness of a PARAFAC decomposition in the fiber selection procedure to determine chlorophenols by means SPME-GC-MS.

    Science.gov (United States)

    Morales, Rocío; Cruz Ortiz, M; Sarabia, Luis A

    2012-05-01

    In this work, a procedure based on solid-phase microextraction and gas chromatography coupled with mass spectrometry is proposed to determine chlorophenols in water without derivatization. The following chlorophenols are studied: 2,4-dichlorophenol; 2,4,6-trichlorophenol; 2,3,4,6-tetrachlorophenol and pentachlorophenol. Three kinds of SPME fibers, polyacrylate, polydimethylsiloxane, and polydimethylsiloxane/divinylbenzene are compared to identify the most suitable one for the extraction process on the basis of two criteria: (a) to select the equilibrium time studying the kinetics of the extraction, and (b) to obtain the best values of the figures of merit. In both cases, a three-way PARAllel FACtor analysis decomposition is used. For the first step, the three-way experimental data are arranged as follows: if I extraction times are considered, the tensor of data, X, of dimensions I × J × K is generated by concatenating the I matrices formed by the abundances of the J m/z ions recorded in K elution times around the retention time for each chlorophenol. The second-order property of PARAFAC (or PARAFAC2) assesses the unequivocal identification of each chlorophenol, as consequence, the loadings in the first mode estimated by the PARAFAC decomposition are the kinetic profile. For the second step, a calibration based on a PARAFAC decomposition is used for each fiber. The best figures of merit were obtained with PDMS/DVB fiber. The values of decision limit, CCα, achieved are between 0.29 and 0.67 μg L(-1) for the four chlorophenols. The accuracy (trueness and precision) of the procedure was assessed. This procedure has been applied to river water samples.

  16. Grounds Maintenance Equipment and Procedures. Building Maintenance. Module VI. Instructor's Guide.

    Science.gov (United States)

    Crank, Virgil

    This curriculum guide, one of six modules keyed to the building maintenance competency profile developed by industry and education professionals, provides materials for two units on grounds maintenance equipment and procedures. The first unit deals with grounds maintenance equipment and includes the following lessons: safety; changing oil/filter…

  17. HangOut: generating clean PSI-BLAST profiles for domains with long insertions.

    Science.gov (United States)

    Kim, Bong-Hyun; Cong, Qian; Grishin, Nick V

    2010-06-15

    Profile-based similarity search is an essential step in structure-function studies of proteins. However, inclusion of non-homologous sequence segments into a profile causes its corruption and results in false positives. Profile corruption is common in multidomain proteins, and single domains with long insertions are a significant source of errors. We developed a procedure (HangOut) that, for a single domain with specified insertion position, cleans erroneously extended PSI-BLAST alignments to generate better profiles. HangOut is implemented in Python 2.3 and runs on all Unix-compatible platforms. The source code is available under the GNU GPL license at http://prodata.swmed.edu/HangOut/. Supplementary data are available at Bioinformatics online.

  18. Analysis of plant gums and saccharide materials in paint samples: comparison of GC-MS analytical procedures and databases.

    Science.gov (United States)

    Lluveras-Tenorio, Anna; Mazurek, Joy; Restivo, Annalaura; Colombini, Maria Perla; Bonaduce, Ilaria

    2012-10-10

    Saccharide materials have been used for centuries as binding media, to paint, write and illuminate manuscripts and to apply metallic leaf decorations. Although the technical literature often reports on the use of plant gums as binders, actually several other saccharide materials can be encountered in paint samples, not only as major binders, but also as additives. In the literature, there are a variety of analytical procedures that utilize GC-MS to characterize saccharide materials in paint samples, however the chromatographic profiles are often extremely different and it is impossible to compare them and reliably identify the paint binder. This paper presents a comparison between two different analytical procedures based on GC-MS for the analysis of saccharide materials in works-of-art. The research presented here evaluates the influence of the analytical procedure used, and how it impacts the sugar profiles obtained from the analysis of paint samples that contain saccharide materials. The procedures have been developed, optimised and systematically used to characterise plant gums at the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). The main steps of the analytical procedures and their optimisation are discussed. The results presented highlight that the two methods give comparable sugar profiles, whether the samples analysed are simple raw materials, pigmented and unpigmented paint replicas, or paint samples collected from hundreds of centuries old polychrome art objects. A common database of sugar profiles of reference materials commonly found in paint samples was thus compiled. The database presents data also from those materials that only contain a minor saccharide fraction. This database highlights how many sources of saccharides can be found in a paint sample, representing an important step forward in the problem of identifying polysaccharide binders in

  19. Accuracy of multi-point boundary crossing time analysis

    Directory of Open Access Journals (Sweden)

    J. Vogt

    2011-12-01

    Full Text Available Recent multi-spacecraft studies of solar wind discontinuity crossings using the timing (boundary plane triangulation method gave boundary parameter estimates that are significantly different from those of the well-established single-spacecraft minimum variance analysis (MVA technique. A large survey of directional discontinuities in Cluster data turned out to be particularly inconsistent in the sense that multi-point timing analyses did not identify any rotational discontinuities (RDs whereas the MVA results of the individual spacecraft suggested that RDs form the majority of events. To make multi-spacecraft studies of discontinuity crossings more conclusive, the present report addresses the accuracy of the timing approach to boundary parameter estimation. Our error analysis is based on the reciprocal vector formalism and takes into account uncertainties both in crossing times and in the spacecraft positions. A rigorous error estimation scheme is presented for the general case of correlated crossing time errors and arbitrary spacecraft configurations. Crossing time error covariances are determined through cross correlation analyses of the residuals. The principal influence of the spacecraft array geometry on the accuracy of the timing method is illustrated using error formulas for the simplified case of mutually uncorrelated and identical errors at different spacecraft. The full error analysis procedure is demonstrated for a solar wind discontinuity as observed by the Cluster FGM instrument.

  20. Ionization profile of beta radiation from radioactive cloud

    International Nuclear Information System (INIS)

    Vujovic, M.; Vojvodic, V.

    1978-01-01

    A method for calculation of the ionization profile induced by beta radiation from a radioactive cloud is given. The procedure can be applied for high altitudes of the could (H 75 km) as well as for lower ones, when the thickness of the cloud must be taken into account. The final result is given in the analytical form. (author)

  1. The Relationship Between Eyewitness Confidence and Identification Accuracy: A New Synthesis.

    Science.gov (United States)

    Wixted, John T; Wells, Gary L

    2017-05-01

    The U.S. legal system increasingly accepts the idea that the confidence expressed by an eyewitness who identified a suspect from a lineup provides little information as to the accuracy of that identification. There was a time when this pessimistic assessment was entirely reasonable because of the questionable eyewitness-identification procedures that police commonly employed. However, after more than 30 years of eyewitness-identification research, our understanding of how to properly conduct a lineup has evolved considerably, and the time seems ripe to ask how eyewitness confidence informs accuracy under more pristine testing conditions (e.g., initial, uncontaminated memory tests using fair lineups, with no lineup administrator influence, and with an immediate confidence statement). Under those conditions, mock-crime studies and police department field studies have consistently shown that, for adults, (a) confidence and accuracy are strongly related and (b) high-confidence suspect identifications are remarkably accurate. However, when certain non-pristine testing conditions prevail (e.g., when unfair lineups are used), the accuracy of even a high-confidence suspect ID is seriously compromised. Unfortunately, some jurisdictions have not yet made reforms that would create pristine testing conditions and, hence, our conclusions about the reliability of high-confidence identifications cannot yet be applied to those jurisdictions. However, understanding the information value of eyewitness confidence under pristine testing conditions can help the criminal justice system to simultaneously achieve both of its main objectives: to exonerate the innocent (by better appreciating that initial, low-confidence suspect identifications are error prone) and to convict the guilty (by better appreciating that initial, high-confidence suspect identifications are surprisingly accurate under proper testing conditions).

  2. Evaluation of the occupational dose in hemodynamic procedures

    International Nuclear Information System (INIS)

    Silva, Amanda J. da; Fernandes, Ivani M.; Sordi, Gian Maria A.A.; Carneiro, Janete C. Gaburo

    2010-01-01

    The purpose of this study was to evaluate the dose received by health professionals in a hemodynamic service. It was necessary to know the profile of these professional, to carry out a survey the occupational external doses during the years 2000 to 2009 and to evaluate the distribution of the effective dose from the special procedures guided by fluoroscopy. A self-applied questionnaire was used to delineate the profile of health professionals, taking into account variables such as gender, age, individual monitoring time, number of jobs and tasks performed in the sector. In addition, it was performed an examination of the external individual monitoring doses from the records of the institution. The sample was composed of 35 professionals, 11 males and 24 females, with mean age of (43.0 +- 10.4) years. The average monitoring time of individuals analyzed within the institution was (11.3 +- 9.1) years, considering the period before the study. The minimum record dose level was 0.2 mSv and the maximum dose was 22.7 mSv. Doctors and nursing assistants were the professionals more exposed to radiation, due probably remaining closer to the examination table and X-ray tube during the interventional procedure. (author)

  3. Simultaneous measure of a spectral line profile and the apparatus function of a Fabry-Perot spectrometer when continuous background is present

    International Nuclear Information System (INIS)

    Moreno, J.M.; Quintanilla, M.; Mar, S.

    1978-01-01

    A deconvolution method of registered profile on a Fabry-Perot spectrometer is developed, when the actual profile of the source is a Voigt pattern together with a continuous background. The reliability and accuracy of the method is tested with theoreticaly simulated profiles. The method is applied both to measure the real line profiles and to find the Fabry-Perot parameters, as a test of its validity on studies of experimental profiles. Both measure types -source profile and apparatus function- are made simultaneously by means of analysis of the variations of registered profile, at 6438.5A Cd line and 6328A He-Ne laser line, varying the optical path between interferometer mirrors. (author) [es

  4. Accuracy of CNV Detection from GWAS Data.

    Directory of Open Access Journals (Sweden)

    Dandan Zhang

    2011-01-01

    Full Text Available Several computer programs are available for detecting copy number variants (CNVs using genome-wide SNP arrays. We evaluated the performance of four CNV detection software suites--Birdsuite, Partek, HelixTree, and PennCNV-Affy--in the identification of both rare and common CNVs. Each program's performance was assessed in two ways. The first was its recovery rate, i.e., its ability to call 893 CNVs previously identified in eight HapMap samples by paired-end sequencing of whole-genome fosmid clones, and 51,440 CNVs identified by array Comparative Genome Hybridization (aCGH followed by validation procedures, in 90 HapMap CEU samples. The second evaluation was program performance calling rare and common CNVs in the Bipolar Genome Study (BiGS data set (1001 bipolar cases and 1033 controls, all of European ancestry as measured by the Affymetrix SNP 6.0 array. Accuracy in calling rare CNVs was assessed by positive predictive value, based on the proportion of rare CNVs validated by quantitative real-time PCR (qPCR, while accuracy in calling common CNVs was assessed by false positive/false negative rates based on qPCR validation results from a subset of common CNVs. Birdsuite recovered the highest percentages of known HapMap CNVs containing >20 markers in two reference CNV datasets. The recovery rate increased with decreased CNV frequency. In the tested rare CNV data, Birdsuite and Partek had higher positive predictive values than the other software suites. In a test of three common CNVs in the BiGS dataset, Birdsuite's call was 98.8% consistent with qPCR quantification in one CNV region, but the other two regions showed an unacceptable degree of accuracy. We found relatively poor consistency between the two "gold standards," the sequence data of Kidd et al., and aCGH data of Conrad et al. Algorithms for calling CNVs especially common ones need substantial improvement, and a "gold standard" for detection of CNVs remains to be established.

  5. High Accuracy Beam Current Monitor System for CEBAF'S Experimental Hall A

    International Nuclear Information System (INIS)

    J. Denard; A. Saha; G. Lavessiere

    2001-01-01

    CEBAF accelerator delivers continuous wave (CW) electron beams to three experimental Halls. In Hall A, all experiments require continuous, non-invasive current measurements and a few experiments require an absolute accuracy of 0.2 % in the current range from 1 to 180 (micro)A. A Parametric Current Transformer (PCT), manufactured by Bergoz, has an accurate and stable sensitivity of 4 (micro)A/V but its offset drifts at the muA level over time preclude its direct use for continuous measurements. Two cavity monitors are calibrated against the PCT with at least 50 (micro)A of beam current. The calibration procedure suppresses the error due to PCT's offset drifts by turning the beam on and off, which is invasive to the experiment. One of the goals of the system is to minimize the calibration time without compromising the measurement's accuracy. The linearity of the cavity monitors is a critical parameter for transferring the accurate calibration done at high currents over the whole dynamic range. The method for measuring accurately the linearity is described

  6. Evaluation of the geometric stability and the accuracy potential of digital cameras — Comparing mechanical stabilisation versus parameterisation

    Science.gov (United States)

    Rieke-Zapp, D.; Tecklenburg, W.; Peipe, J.; Hastedt, H.; Haig, Claudia

    Recent tests on the geometric stability of several digital cameras that were not designed for photogrammetric applications have shown that the accomplished accuracies in object space are either limited or that the accuracy potential is not exploited to the fullest extent. A total of 72 calibrations were calculated with four different software products for eleven digital camera models with different hardware setups, some with mechanical fixation of one or more parts. The calibration procedure was chosen in accord to a German guideline for evaluation of optical 3D measuring systems [VDI/VDE, VDI/VDE 2634 Part 1, 2002. Optical 3D Measuring Systems-Imaging Systems with Point-by-point Probing. Beuth Verlag, Berlin]. All images were taken with ringflashes which was considered a standard method for close-range photogrammetry. In cases where the flash was mounted to the lens, the force exerted on the lens tube and the camera mount greatly reduced the accomplished accuracy. Mounting the ringflash to the camera instead resulted in a large improvement of accuracy in object space. For standard calibration best accuracies in object space were accomplished with a Canon EOS 5D and a 35 mm Canon lens where the focusing tube was fixed with epoxy (47 μm maximum absolute length measurement error in object space). The fixation of the Canon lens was fairly easy and inexpensive resulting in a sevenfold increase in accuracy compared with the same lens type without modification. A similar accuracy was accomplished with a Nikon D3 when mounting the ringflash to the camera instead of the lens (52 μm maximum absolute length measurement error in object space). Parameterisation of geometric instabilities by introduction of an image variant interior orientation in the calibration process improved results for most cameras. In this case, a modified Alpa 12 WA yielded the best results (29 μm maximum absolute length measurement error in object space). Extending the parameter model with Fi

  7. Data Transfer Advisor with Transport Profiling Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Nageswara S. [ORNL; Liu, Qiang [ORNL; Yun, Daqing [Harrisburg University; Wu, Chase Qishi [New Jersey Institute of Technology; Kettimuthu, R. [Argonne National Laboratory (ANL); Jung, Eun-sung [Argonne National Laboratory (ANL)

    2017-11-01

    The network infrastructures have been rapidly upgraded in many high-performance networks (HPNs). However, such infrastructure investment has not led to corresponding performance improvement in big data transfer, especially at the application layer, largely due to the complexity of optimizing transport control on end hosts. We design and implement ProbData, a PRofiling Optimization Based DAta Transfer Advisor, to help users determine the most effective data transfer method with the most appropriate control parameter values to achieve the best data transfer performance. ProbData employs a profiling optimization based approach to exploit the optimal operational zone of various data transfer methods in support of big data transfer in extreme scale scientific applications. We present a theoretical framework of the optimized profiling approach employed in ProbData as wellas its detailed design and implementation. The advising procedure and performance benefits of ProbData are illustrated and evaluated by proof-of-concept experiments in real-life networks.

  8. Technical procedures for land use, Deaf Smith County site, Texas: Environmental Field Program: Final draft

    International Nuclear Information System (INIS)

    1987-09-01

    This volume contains Technical Procedures pursuant to the Land Use Site Study Plan including land use data acquisition, land use/land cover map compilation, verification of land use/land cover map accuracy, and land use/land cover data analysis. 22 refs., 5 figs

  9. Enhancing the Accuracy of Advanced High Temperature Mechanical Testing through Thermography

    Directory of Open Access Journals (Sweden)

    Jonathan Jones

    2018-03-01

    Full Text Available This paper describes the advantages and enhanced accuracy thermography provides to high temperature mechanical testing. This technique is not only used to monitor, but also to control test specimen temperatures where the infra-red technique enables accurate non-invasive control of rapid thermal cycling for non-metallic materials. Isothermal and dynamic waveforms are employed over a 200–800 °C temperature range to pre-oxidised and coated specimens to assess the capability of the technique. This application shows thermography to be accurate to within ±2 °C of thermocouples, a standardised measurement technique. This work demonstrates the superior visibility of test temperatures previously unobtainable by conventional thermocouples or even more modern pyrometers that thermography can deliver. As a result, the speed and accuracy of thermal profiling, thermal gradient measurements and cold/hot spot identification using the technique has increased significantly to the point where temperature can now be controlled by averaging over a specified area. The increased visibility of specimen temperatures has revealed additional unknown effects such as thermocouple shadowing, preferential crack tip heating within an induction coil, and, fundamental response time of individual measurement techniques which are investigated further.

  10. 241-AZ-101 Mixer Pump Demonstration Test Gamma Cart Acceptance Test Procedure and Quality Test Plan (ATP and QTP)

    International Nuclear Information System (INIS)

    WHITE, D.A.

    2000-01-01

    Shop test of the sludge mobilization cart system to be used in the AZ-101 Mixer Pump Demonstration Test Tests hardware and software. This procedure involves testing the Instrumentation involved with the Gamma Cart System, local and remote, including depth indicators, speed controls, interface to data acquisition software and the raising and lowering functions. This Procedure will be performed twice, once for each Gamma Cart System. This procedure does not test the accuracy of the data acquisition software

  11. 241-AZ-101 Mixer Pump Demonstration Test Gamma Cart Acceptance Test Procedure and Quality Test Plan (ATP and QTP)

    International Nuclear Information System (INIS)

    WHITE, D.A.

    2000-01-01

    Shop Test of the Gamma Cart System to be used in the AZ-101 Mixer Pump Demonstration Test. Tests hardware and software. This procedure involves testing the Instrumentation involved with the Gamma Cart System, local and remote, including: depth indicators, speed controls, interface to data acquisition software and the raising and lowering functions. This Procedure will be performed twice, once for each Gamma Cart System. This procedure does not test the accuracy of the data acquisition software

  12. Accuracy of CO2 sensors in commercial buildings: a pilotstudy

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

    2006-10-01

    Carbon dioxide (CO{sub 2}) sensors are often deployed in commercial buildings to obtain CO{sub 2} data that are used to automatically modulate rates of outdoor air supply. The goal is to keep ventilation rates at or above code requirements, but to also to save energy by avoiding over ventilation relative to code requirements. However, there have been many anecdotal reports of poor CO{sub 2} sensor performance in actual commercial building applications. This study evaluated the accuracy of 44 CO{sub 2} sensors located in nine commercial buildings to determine if CO{sub 2} sensor performance, in practice, is generally acceptable or problematic. CO{sub 2} measurement errors varied widely and were sometimes hundreds of parts per million. Despite its small size, this study provides a strong indication that the accuracy of CO{sub 2} sensors used in commercial buildings is frequently less than is needed to measure peak indoor-outdoor CO{sub 2} concentration differences with less than a 20% error. Thus, we conclude that there is a need for more accurate CO{sub 2} sensors and/or better sensor maintenance or calibration procedures.

  13. Metric Accuracy Evaluation of Dense Matching Algorithms in Archeological Applications

    Directory of Open Access Journals (Sweden)

    C. Re

    2011-12-01

    Full Text Available In the cultural heritage field the recording and documentation of small and medium size objects with very detailed Digital Surface Models (DSM is readily possible by through the use of high resolution and high precision triangulation laser scanners. 3D surface recording of archaeological objects can be easily achieved in museums; however, this type of record can be quite expensive. In many cases photogrammetry can provide a viable alternative for the generation of DSMs. The photogrammetric procedure has some benefits with respect to laser survey. The research described in this paper sets out to verify the reconstruction accuracy of DSMs of some archaeological artifacts obtained by photogrammetric survey. The experimentation has been carried out on some objects preserved in the Petrie Museum of Egyptian Archaeology at University College London (UCL. DSMs produced by two photogrammetric software packages are compared with the digital 3D model obtained by a state of the art triangulation color laser scanner. Intercomparison between the generated DSM has allowed an evaluation of metric accuracy of the photogrammetric approach applied to archaeological documentation and of precision performances of the two software packages.

  14. Cell-specific prediction and application of drug-induced gene expression profiles.

    Science.gov (United States)

    Hodos, Rachel; Zhang, Ping; Lee, Hao-Chih; Duan, Qiaonan; Wang, Zichen; Clark, Neil R; Ma'ayan, Avi; Wang, Fei; Kidd, Brian; Hu, Jianying; Sontag, David; Dudley, Joel

    2018-01-01

    Gene expression profiling of in vitro drug perturbations is useful for many biomedical discovery applications including drug repurposing and elucidation of drug mechanisms. However, limited data availability across cell types has hindered our capacity to leverage or explore the cell-specificity of these perturbations. While recent efforts have generated a large number of drug perturbation profiles across a variety of human cell types, many gaps remain in this combinatorial drug-cell space. Hence, we asked whether it is possible to fill these gaps by predicting cell-specific drug perturbation profiles using available expression data from related conditions--i.e. from other drugs and cell types. We developed a computational framework that first arranges existing profiles into a three-dimensional array (or tensor) indexed by drugs, genes, and cell types, and then uses either local (nearest-neighbors) or global (tensor completion) information to predict unmeasured profiles. We evaluate prediction accuracy using a variety of metrics, and find that the two methods have complementary performance, each superior in different regions in the drug-cell space. Predictions achieve correlations of 0.68 with true values, and maintain accurate differentially expressed genes (AUC 0.81). Finally, we demonstrate that the predicted profiles add value for making downstream associations with drug targets and therapeutic classes.

  15. Convolution based profile fitting

    International Nuclear Information System (INIS)

    Kern, A.; Coelho, A.A.; Cheary, R.W.

    2002-01-01

    Full text: In convolution based profile fitting, profiles are generated by convoluting functions together to form the observed profile shape. For a convolution of 'n' functions this process can be written as, Y(2θ)=F 1 (2θ)x F 2 (2θ)x... x F i (2θ)x....xF n (2θ). In powder diffractometry the functions F i (2θ) can be interpreted as the aberration functions of the diffractometer, but in general any combination of appropriate functions for F i (2θ) may be used in this context. Most direct convolution fitting methods are restricted to combinations of F i (2θ) that can be convoluted analytically (e.g. GSAS) such as Lorentzians, Gaussians, the hat (impulse) function and the exponential function. However, software such as TOPAS is now available that can accurately convolute and refine a wide variety of profile shapes numerically, including user defined profiles, without the need to convolute analytically. Some of the most important advantages of modern convolution based profile fitting are: 1) virtually any peak shape and angle dependence can normally be described using minimal profile parameters in laboratory and synchrotron X-ray data as well as in CW and TOF neutron data. This is possible because numerical convolution and numerical differentiation is used within the refinement procedure so that a wide range of functions can easily be incorporated into the convolution equation; 2) it can use physically based diffractometer models by convoluting the instrument aberration functions. This can be done for most laboratory based X-ray powder diffractometer configurations including conventional divergent beam instruments, parallel beam instruments, and diffractometers used for asymmetric diffraction. It can also accommodate various optical elements (e.g. multilayers and monochromators) and detector systems (e.g. point and position sensitive detectors) and has already been applied to neutron powder diffraction systems (e.g. ANSTO) as well as synchrotron based

  16. Grey-scale conversion X-ray mapping by EDS of multielement and multiphase layered microstructures

    DEFF Research Database (Denmark)

    Dahl, Kristian Vinter; Hald, John; Horsewell, Andy

    2007-01-01

    been obtained for several long-term isothermal heat treatments in which significant interdiffusion has taken place. The resulting composition profiles have greatly improved counting statistics compared to traditional point-by-point scans for the same scanning electron microscope time and may......procedure for grey-scale conversion of energy dispersive spectroscopy X-ray maps has been developed, which is particularly useful for the plotting of line composition profiles across modified layered engineering surfaces. The method involves (a) the collection of grey-scale elemental maps, (b......, the procedure has been applied to a layered microstructure that results from a plasma-sprayed metallic MCrAlY coating onto a nickel-superalloy turbine blade. As a further demonstration of the accuracy and amount of compositional data that can be obtained with this procedure, measured compositional profiles have...

  17. Velocity Profile measurements in two-phase flow using multi-wave sensors

    Science.gov (United States)

    Biddinika, M. K.; Ito, D.; Takahashi, H.; Kikura, H.; Aritomi, M.

    2009-02-01

    Two-phase flow has been recognized as one of the most important phenomena in fluid dynamics. In addition, gas-liquid two-phase flow appears in various industrial fields such as chemical industries and power generations. In order to clarify the flow structure, some flow parameters have been measured by using many effective measurement techniques. The velocity profile as one of the important flow parameter, has been measured by using ultrasonic velocity profile (UVP) technique. This technique can measure velocity distributions along a measuring line, which is a beam formed by pulse ultrasounds. Furthermore, a multi-wave sensor can measure the velocity profiles of both gas and liquid phase using UVP method. In this study, two types of multi-wave sensors are used. A sensor has cylindrical shape, and another one has square shape. The piezoelectric elements of each sensor have basic frequencies of 8 MHz for liquid phase and 2 MHz for gas phase, separately. The velocity profiles of air-water bubbly flow in a vertical rectangular channel were measured by using these multi-wave sensors, and the validation of the measuring accuracy was performed by the comparison between the velocity profiles measured by two multi-wave sensors.

  18. Velocity Profile measurements in two-phase flow using multi-wave sensors

    International Nuclear Information System (INIS)

    Biddinika, M K; Ito, D; Takahashi, H; Kikura, H; Aritomi, M

    2009-01-01

    Two-phase flow has been recognized as one of the most important phenomena in fluid dynamics. In addition, gas-liquid two-phase flow appears in various industrial fields such as chemical industries and power generations. In order to clarify the flow structure, some flow parameters have been measured by using many effective measurement techniques. The velocity profile as one of the important flow parameter, has been measured by using ultrasonic velocity profile (UVP) technique. This technique can measure velocity distributions along a measuring line, which is a beam formed by pulse ultrasounds. Furthermore, a multi-wave sensor can measure the velocity profiles of both gas and liquid phase using UVP method. In this study, two types of multi-wave sensors are used. A sensor has cylindrical shape, and another one has square shape. The piezoelectric elements of each sensor have basic frequencies of 8 MHz for liquid phase and 2 MHz for gas phase, separately. The velocity profiles of air-water bubbly flow in a vertical rectangular channel were measured by using these multi-wave sensors, and the validation of the measuring accuracy was performed by the comparison between the velocity profiles measured by two multi-wave sensors.

  19. Lowest-order average effect of turbulence on atmospheric profiles derived from radio occultation

    International Nuclear Information System (INIS)

    Eshleman, V.R.; Haugstad, B.S.

    1977-01-01

    Turbulence in planetary atmospheres and ionospheres causes changes in angles of refraction of radio waves used in occultation experiments. Atmospheric temperature and pressure profiles, and ionospheric electron concentration profiles, derived from radio occultation measurements of Doppler frequency contain errors due to such angular offsets. The lowest-order average errors are derived from a geometrical-optics treatment of the radio-wave phase advance caused by the addition of uniform turbulence to an initially homogeneous medium. It is concluded that the average profile errors are small and that precise Doppler frequency measurements at two or more wavelengths could be used to help determine characteristics of the turbulence, as well as accuracy limits and possible correction terms for the profiles. However, a more detailed study of both frequency and intensity characteristics in radio and optical occultation measurements of turbulent planetary atmospheres and ionospheres is required to realize the full potential of such measurements

  20. Social Power Increases Interoceptive Accuracy

    Directory of Open Access Journals (Sweden)

    Mehrad Moeini-Jazani

    2017-08-01

    Full Text Available Building on recent psychological research showing that power increases self-focused attention, we propose that having power increases accuracy in perception of bodily signals, a phenomenon known as interoceptive accuracy. Consistent with our proposition, participants in a high-power experimental condition outperformed those in the control and low-power conditions in the Schandry heartbeat-detection task. We demonstrate that the effect of power on interoceptive accuracy is not explained by participants’ physiological arousal, affective state, or general intention for accuracy. Rather, consistent with our reasoning that experiencing power shifts attentional resources inward, we show that the effect of power on interoceptive accuracy is dependent on individuals’ chronic tendency to focus on their internal sensations. Moreover, we demonstrate that individuals’ chronic sense of power also predicts interoceptive accuracy similar to, and independent of, how their situationally induced feeling of power does. We therefore provide further support on the relation between power and enhanced perception of bodily signals. Our findings offer a novel perspective–a psychophysiological account–on how power might affect judgments and behavior. We highlight and discuss some of these intriguing possibilities for future research.

  1. Prediction of renal function (GFR) from cystatin C and creatinine in children: Body cell mass increases accuracy of the estimate

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Bøgsted, Martin

    using robust regression in a forward, stepwise procedure. GFR (mL/min) was the dependent variable. The accuracy and precision of the prediction model were compared to other prediction models from the literature, using k-fold cross-validation. Local constants and coefficients were calculated for all...

  2. The Effects of Two Direct Instruction Teaching Procedures to Basic Skills to Two Students with Disabilities

    Directory of Open Access Journals (Sweden)

    Annelie Fjortoft

    2014-06-01

    Full Text Available The first study focused on increasing her ability to identify letters and to write these letters. The research was conducted in a resource room setting located in a public school in a large urban school district. The effects of employing DI flashcards on letter recognition and letter writing were evaluated in a multiple baseline design. Overall the effects of the experiment were positive; the participant improved her accuracy letter identification accuracy and her skills at writing her letters from the alphabet. The time, cost, and effort needed for Experiment I was minimal and the student enjoyed the procedures. A second study was conducted with a first grade boy. We wanted to determine the effectiveness of Teach Your Child to Read in 100 Easy Lessons along with a DI flashcard procedure to improve a first grade student’s ability to identify sounds and sight words within a public school behavior intervention (BI classroom setting. Overall the effects of the second experiment were also quite positive. The participant improved his accuracy and ability to say the letter-sounds and target words. Suggestions for future research were made.

  3. A high-frequency sonar for profiling small-scale subaqueous bedforms

    Science.gov (United States)

    Dingler, J.R.; Boylls, J.C.; Lowe, R.L.

    1977-01-01

    A high-resolution ultrasonic profiler has been developed which permits both laboratory and field studies of small-scale subaqueous bedforms. The device uses a 2.5-cm diameter piezoelectric ceramic crystal pulsed at a frequency of 4.5 MHz to obtain vertical accuracy and resolution of at least 1 mm. Compared to other small-scale profiling methods, this ultrasonic technique profiles the bottom more accurately and more rapidly without disturbing the bedforms. These characteristics are vital in wave-dominated nearshore zones where oscillatory flow and low visibility for the most part have stymied detailed bedform studies. In the laboratory the transducer is mounted directly to an instrument carriage. For field work the transducer housing is mounted in a 2 m long aluminum frame which is situated and operated by scuba divers. Observations using the device include ripple geometry and migration, the suspension height of sand during sheet flow, and long-term erosion/deposition at a point. ?? 1977.

  4. Projected potential profiles across interfaces obtained by reconstructing the exit face wave function from through focal series

    International Nuclear Information System (INIS)

    Bhattacharyya, Somnath; Koch, Christoph T.; Ruehle, Manfred

    2006-01-01

    An iterative method for reconstructing the exit face wave function from a through focal series of transmission electron microscopy image line profiles across an interface is presented. Apart from high-resolution images recorded with small changes in defocus, this method works also well for a large defocus range as used for Fresnel imaging. Using the phase-object approximation the projected electrostatic as well as the absorptive potential profiles across an interface are determined from this exit face wave function. A new experimental image alignment procedure was developed in order to align images with large relative defocus shift. The performance of this procedure is shown to be superior to other image alignment procedures existing in the literature. The reconstruction method is applied to both simulated and experimental images

  5. How robotic-assisted surgery can decrease the risk of mucosal tear during Heller myotomy procedure?

    Science.gov (United States)

    Ballouhey, Quentin; Dib, Nabil; Binet, Aurélien; Carcauzon-Couvrat, Véronique; Clermidi, Pauline; Longis, Bernard; Lardy, Hubert; Languepin, Jane; Cros, Jérôme; Fourcade, Laurent

    2017-06-01

    We report the first description of robotic-assisted Heller myotomy in children. The purpose of this study was to improve the safety of Heller myotomy by demonstrating, in two adolescent patients, the contribution of the robot to the different steps of this procedure. Due to the robot's freedom of movement and three-dimensional vision, there was an improvement in the accuracy, a gain in the safety regarding different key-points, decreasing the risk of mucosal perforation associated with this procedure.

  6. Validation of the "Security Needs Assessment Profile" for measuring the profiles of security needs of Chinese forensic psychiatric inpatients.

    Science.gov (United States)

    Siu, B W M; Au-Yeung, C C Y; Chan, A W L; Chan, L S Y; Yuen, K K; Leung, H W; Yan, C K; Ng, K K; Lai, A C H; Davies, S; Collins, M

    Mapping forensic psychiatric services with the security needs of patients is a salient step in service planning, audit and review. A valid and reliable instrument for measuring the security needs of Chinese forensic psychiatric inpatients was not yet available. This study aimed to develop and validate the Chinese version of the Security Needs Assessment Profile for measuring the profiles of security needs of Chinese forensic psychiatric inpatients. The Security Needs Assessment Profile by Davis was translated into Chinese. Its face validity, content validity, construct validity and internal consistency reliability were assessed by measuring the security needs of 98 Chinese forensic psychiatric inpatients. Principal factor analysis for construct validity provided a six-factor security needs model explaining 68.7% of the variance. Based on the Cronbach's alpha coefficient, the internal consistency reliability was rated as acceptable for procedural security (0.73), and fair for both physical security (0.62) and relational security (0.58). A significant sex difference (p=0.002) in total security score was found. The Chinese version of the Security Needs Assessment Profile is a valid and reliable instrument for assessing the security needs of Chinese forensic psychiatric inpatients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. A finite volume procedure for fluid flow, heat transfer and solid-body stress analysis

    KAUST Repository

    Jagad, P. I.

    2018-04-12

    A unified cell-centered unstructured mesh finite volume procedure is presented for fluid flow, heat transfer and solid-body stress analysis. An in-house procedure (A. W. Date, Solution of Transport Equations on Unstructured Meshes with Cell-Centered Colocated Variables. Part I: Discretization, International Journal of Heat and Mass Transfer, vol. 48 (6), 1117-1127, 2005) is extended to include the solid-body stress analysis. The transport terms for a cell-face are evaluated in a structured grid-like manner. The Cartesian gradients at the center of each cell-face are evaluated using the coordinate transformation relations. The accuracy of the procedure is demonstrated by solving several benchmark problems involving different boundary conditions, source terms, and types of loading.

  8. Tool breakage detection from 2D workpiece profile using vision method

    International Nuclear Information System (INIS)

    Lee, W K; Ratnam, M M; Ahmad, Z A

    2016-01-01

    In-process tool breakage monitoring can significantly save cost and prevent damages to machine tool. In this paper, a machine vision approach was employed to detect the tool fracture in commercial aluminium oxide ceramic cutting tool during turning of AISI 52100 hardened steel. The contour of the workpiece profile was captured with the aid of backlighting during turning using a high-resolution DSLR camera with a shutter speed of 1/4000 s. The surface profile of the workpiece was extracted to sub-pixel accuracy using the invariant moment method. The effect of fracture in ceramic cutting tools on the surface profile signature of the machined workpiece using autocorrelation was studied. Fracture in the aluminum oxide ceramic tool was found to cause the peaks of autocorrelation function of the workpiece profile to decrease rapidly as the lag distance increased. The envelope of the peaks of the autocorrelation function was observed to deviate significantly from one another at different workpiece angles when the tool has fractured due to the continuous fracture of ceramic cutting insert during machining. (paper)

  9. Accuracy of whole-body plethysmography requires biological calibration

    DEFF Research Database (Denmark)

    Poorisrisak, Porntiva; Vrang, Carsten; Henriksen, Jorn Molgaard

    2009-01-01

    procedure: (1) seven healthy young children were brought to each of the six centers for sRaw measurements; and (2) 105 healthy preschool children (52 boys; mean age, 5.1 years; interquartile range, 4.3 to 6.0) were recruited locally for sRaw measurements. RESULTS: (1) The sRaw of the seven-children study...... preschool children) were generated and were without significant difference between centers and independent of height, weight, age, and gender. We subsequently pooled these normative data (105 children) with our previous data from 121 healthy young children (overall mean sRaw, 1.27; SD, 0.25). CONCLUSION......: Control using biological standards revealed errors in the factory setting and highlights the need for developing methods for verification of resistance measures to assure accuracy. Normative data were subsequently generated. Importantly, other centers using such normative data should first consider proper...

  10. UAV-Borne Profiling Radar for Forest Research

    Directory of Open Access Journals (Sweden)

    Yuwei Chen

    2017-01-01

    Full Text Available Microwave Radar is an attractive solution for forest mapping and inventories because microwave signals penetrates into the forest canopy and the backscattering signal can provide information regarding the whole forest structure. Satellite-borne and airborne imaging radars have been used in forest resources mapping for many decades. However, their accuracy with respect to the main forest inventory attributes substantially varies depending on the wavelength and techniques used in the estimation. Systems providing canopy backscatter as a function of canopy height are, practically speaking, missing. Therefore, there is a need for a radar system that would enable the scientific community to better understand the radar backscatter response from the forest canopy. Consequently, we undertook a research study to develop an unmanned aerial vehicle (UAV-borne profiling (i.e., waveform radar that could be used to improve the understanding of the radar backscatter response for forestry mapping and inventories. A frequency modulation continuous waveform (FMCW profiling radar, termed FGI-Tomoradar, was introduced, designed and tested. One goal is the total weight of the whole system is less than 7 kg, including the radar system and georeferencing system, with centimetre-level positioning accuracy. Achieving this weight goal would enable the FGI-Tomoradar system to be installed on the Mini-UAV platform. The prototype system had all four linear polarization measuring capabilities, with bistatic configuration in Ku-band. In system performance tests in this study, FGI-Tomoradar was mounted on a manned helicopter together with a Riegl VQ-480-U laser scanner and tested in several flight campaigns performed at the Evo site, Finland. Airborne laser scanning data was simultaneously collected to investigate the differences and similarities of the outputs for the same target area for better understanding the penetration of the microwave signal into the forest canopy

  11. Cognitive profile of students who enter higher education with an indication of dyslexia.

    Directory of Open Access Journals (Sweden)

    Maaike Callens

    Full Text Available For languages other than English there is a lack of empirical evidence about the cognitive profile of students entering higher education with a diagnosis of dyslexia. To obtain such evidence, we compared a group of 100 Dutch-speaking students diagnosed with dyslexia with a control group of 100 students without learning disabilities. Our study showed selective deficits in reading and writing (effect sizes for accuracy between d = 1 and d = 2, arithmetic (d≈1, and phonological processing (d>0.7. Except for spelling, these deficits were larger for speed related measures than for accuracy related measures. Students with dyslexia also performed slightly inferior on the KAIT tests of crystallized intelligence, due to the retrieval of verbal information from long-term memory. No significant differences were observed in the KAIT tests of fluid intelligence. The profile we obtained agrees with a recent meta-analysis of English findings suggesting that it generalizes to all alphabetic languages. Implications for special arrangements for students with dyslexia in higher education are outlined.

  12. A simplified LBB evaluation procedure for austenitic and ferritic steel piping

    International Nuclear Information System (INIS)

    Gamble, R.M.; Wichman, K.R.

    1997-01-01

    The NRC previously has approved application of LBB analysis as a means to demonstrate that the probability of pipe rupture was extremely low so that dynamic loads associated with postulated pipe break could be excluded from the design basis (1). The purpose of this work was to: (1) define simplified procedures that can be used by the NRC to compute allowable lengths for circumferential throughwall cracks and assess margin against pipe fracture, and (2) verify the accuracy of the simplified procedures by comparison with available experimental data for piping having circumferential throughwall flaws. The development of the procedures was performed using techniques similar to those employed to develop ASME Code flaw evaluation procedures. The procedures described in this report are applicable to pipe and pipe fittings with: (1) wrought austenitic steel (Ni-Cr-Fe alloy) having a specified minimum yield strength less than 45 ksi, and gas metal-arc, submerged arc and shielded metal-arc austentic welds, and (2) seamless or welded wrought carbon steel having a minimum yield strength not greater than 40 ksi, and associated weld materials. The procedures can be used for cast austenitic steel when adequate information is available to place the cast material toughness into one of the categories identified later in this report for austenitic wrought and weld materials

  13. A simplified LBB evaluation procedure for austenitic and ferritic steel piping

    Energy Technology Data Exchange (ETDEWEB)

    Gamble, R.M.; Wichman, K.R.

    1997-04-01

    The NRC previously has approved application of LBB analysis as a means to demonstrate that the probability of pipe rupture was extremely low so that dynamic loads associated with postulated pipe break could be excluded from the design basis (1). The purpose of this work was to: (1) define simplified procedures that can be used by the NRC to compute allowable lengths for circumferential throughwall cracks and assess margin against pipe fracture, and (2) verify the accuracy of the simplified procedures by comparison with available experimental data for piping having circumferential throughwall flaws. The development of the procedures was performed using techniques similar to those employed to develop ASME Code flaw evaluation procedures. The procedures described in this report are applicable to pipe and pipe fittings with: (1) wrought austenitic steel (Ni-Cr-Fe alloy) having a specified minimum yield strength less than 45 ksi, and gas metal-arc, submerged arc and shielded metal-arc austentic welds, and (2) seamless or welded wrought carbon steel having a minimum yield strength not greater than 40 ksi, and associated weld materials. The procedures can be used for cast austenitic steel when adequate information is available to place the cast material toughness into one of the categories identified later in this report for austenitic wrought and weld materials.

  14. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Bernini, Patrizia; Bertini, Ivano, E-mail: bertini@cerm.unifi.it; Luchinat, Claudio [University of Florence, Magnetic Resonance Center (CERM) (Italy); Nincheri, Paola; Staderini, Samuele [FiorGen Foundation (Italy); Turano, Paola [University of Florence, Magnetic Resonance Center (CERM) (Italy)

    2011-04-15

    {sup 1}H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  15. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    Science.gov (United States)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  16. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    International Nuclear Information System (INIS)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-01-01

    1 H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0−4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  17. Identification and real time control of current profile in Tore-supra: algorithms and simulation; Identification et controle en temps reel du profil de courant dans Tore Supra: algorithmes et simulations

    Energy Technology Data Exchange (ETDEWEB)

    Houy, P

    1999-10-15

    The aim of this work is to propose a real-time control of the current profile in order to achieve reproducible operating modes with improved energetic confinement in tokamaks. The determination of the profile is based on measurements given by interferometry and polarimetry diagnostics. Different ways to evaluate and improve the accuracy of these measurements are exposed. The position and the shape of a plasma are controlled by the poloidal system that forces them to cope with standard values. Gas or neutral ions or ice pellet or extra power injection are technical means used to control other plasma parameters. These controls are performed by servo-controlled loops. The poloidal system of Tore-supra is presented. The main obstacle to a reliable determination of the current profile is the fact that slightly different Faraday angles lead to very different profiles. The direct identification method that is exposed in this work, gives the profile that minimizes the square of the margin between measured and computed values. The different algorithms proposed to control current profiles on Tore-supra have been validated by using a plasma simulation. The code Cronos that solves the resistive diffusion equation of current has been used. (A.C.)

  18. Visualisation of air–water bubbly column flow using array Ultrasonic Velocity Profiler

    Directory of Open Access Journals (Sweden)

    Munkhbat Batsaikhan

    2017-11-01

    Full Text Available In the present work, an experimental study of bubbly two-phase flow in a rectangular bubble column was performed using two ultrasonic array sensors, which can measure the instantaneous velocity of gas bubbles on multiple measurement lines. After the sound pressure distribution of sensors had been evaluated with a needle hydrophone technique, the array sensors were applied to two-phase bubble column. To assess the accuracy of the measurement system with array sensors for one and two-dimensional velocity, a simultaneous measurement was performed with an optical measurement technique called particle image velocimetry (PIV. Experimental results showed that accuracy of the measurement system with array sensors is under 10% for one-dimensional velocity profile measurement compared with PIV technique. The accuracy of the system was estimated to be under 20% along the mean flow direction in the case of two-dimensional vector mapping.

  19. High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging

    International Nuclear Information System (INIS)

    Bel, Arjan; Vos, Pieter H.; Rodrigus, Patrick T. R.; Creutzberg, Carien L.; Visser, Andries G.; Stroom, Joep C.; Lebesque, Joos V.

    1996-01-01

    Purpose: To investigate in three institutions, The Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis [AvL]), Dr. Daniel den Hoed Cancer Center (DDHC), and Dr, Bernard Verbeeten Institute (BVI), how much the patient setup accuracy for irradiation of prostate cancer can be improved by an offline setup verification and correction procedure, using portal imaging. Methods and Materials: The verification procedure consisted of two stages. During the first stage, setup deviations were measured during a number (N max ) of consecutive initial treatment sessions. The length of the average three dimensional (3D) setup deviation vector was compared with an action level for corrections, which shrunk with the number of setup measurements. After a correction was applied, N max measurements had to be performed again. Each institution chose different values for the initial action level (6, 9, and 10 mm) and N max (2 and 4). The choice of these parameters was based on a simulation of the procedure, using as input preestimated values of random and systematic deviations in each institution. During the second stage of the procedure, with weekly setup measurements, the AvL used a different criterion ('outlier detection') for corrective actions than the DDHC and the BVI ('sliding average'). After each correction the first stage of the procedure was restarted. The procedure was tested for 151 patients (62 in AvL, 47 in DDHC, and 42 in BVI) treated for prostate carcinoma. Treatment techniques and portal image acquisition and analysis were different in each institution. Results: The actual distributions of random and systematic deviations without corrections were estimated by eliminating the effect of the corrections. The percentage of mean (systematic) 3D deviations larger than 5 mm was 26% for the AvL and the DDHC, and 36% for the BVI. The setup accuracy after application of the procedure was considerably improved (percentage of mean 3D deviations larger than 5 mm was 1.6% in the

  20. The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling.

    Science.gov (United States)

    Mohseni, Masood; Ebneshahidi, Amin

    2014-05-01

    One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an elastomeric pump available in our market. We examined 10 elastomeric infusion pumps (BOT-802, Nanchang Biotek Medical Device Company, China) with 100 mL capacity and nominal flow of 5 mL/h. Each pump was filled for three times, accounting for 30 series of experiments. A microset scaled in mL was used to measure the pump deliveries. Flow profile and reliability of infusion rate were analyzed after repeated use. The mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not statistically significant (5.01 ± 0.07 vs. 5.03 ± 0.06 vs. 5.06 ± 0.08 mL/h; P = 0.81). The percentage of the flow rate error (deviation from 5 mL/h ± 15%) was 100% in the first and second hours of infusion, 96% in the third hour, 60% in the 20th hour and zero percent in the rest of the infusion time. This study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. These laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia.

  1. MPDATA: Third-order accuracy for variable flows

    Science.gov (United States)

    Waruszewski, Maciej; Kühnlein, Christian; Pawlowska, Hanna; Smolarkiewicz, Piotr K.

    2018-04-01

    This paper extends the multidimensional positive definite advection transport algorithm (MPDATA) to third-order accuracy for temporally and spatially varying flows. This is accomplished by identifying the leading truncation error of the standard second-order MPDATA, performing the Cauchy-Kowalevski procedure to express it in a spatial form and compensating its discrete representation-much in the same way as the standard MPDATA corrects the first-order accurate upwind scheme. The procedure of deriving the spatial form of the truncation error was automated using a computer algebra system. This enables various options in MPDATA to be included straightforwardly in the third-order scheme, thereby minimising the implementation effort in existing code bases. Following the spirit of MPDATA, the error is compensated using the upwind scheme resulting in a sign-preserving algorithm, and the entire scheme can be formulated using only two upwind passes. Established MPDATA enhancements, such as formulation in generalised curvilinear coordinates, the nonoscillatory option or the infinite-gauge variant, carry over to the fully third-order accurate scheme. A manufactured 3D analytic solution is used to verify the theoretical development and its numerical implementation, whereas global tracer-transport benchmarks demonstrate benefits for chemistry-transport models fundamental to air quality monitoring, forecasting and control. A series of explicitly-inviscid implicit large-eddy simulations of a convective boundary layer and explicitly-viscid simulations of a double shear layer illustrate advantages of the fully third-order-accurate MPDATA for fluid dynamics applications.

  2. Load demand profile for a large charging station of a fleet of all-electric plug-in buses

    Directory of Open Access Journals (Sweden)

    Mario A. Rios

    2014-08-01

    Full Text Available This study proposes a general procedure to compute the load demand profile from a parking lot where a fleet of buses with electric propulsion mechanisms are charged. Such procedure is divided in three different stages, the first one models the daily energy utilisation of the batteries based on Monte Carlo simulations and route characteristics. The second one models the process in the charging station based on discrete event simulation of queues of buses served by a lot of available chargers. The third step computes the final demand profile in the parking lot because of the charging process based on the power consumption of batteries’ chargers and the utilisation of the available charges. The proposed procedure allows the computation of the number of required batteries’ chargers to be installed in a charging station placed at a parking lot in order to satisfy and ensure the operation of the fleet, the computation of the power demand profile and the peak load and the computation of the general characteristics of electrical infrastructure to supply the power to the station.

  3. Airline Passenger Profiling Based on Fuzzy Deep Machine Learning.

    Science.gov (United States)

    Zheng, Yu-Jun; Sheng, Wei-Guo; Sun, Xing-Ming; Chen, Sheng-Yong

    2017-12-01

    Passenger profiling plays a vital part of commercial aviation security, but classical methods become very inefficient in handling the rapidly increasing amounts of electronic records. This paper proposes a deep learning approach to passenger profiling. The center of our approach is a Pythagorean fuzzy deep Boltzmann machine (PFDBM), whose parameters are expressed by Pythagorean fuzzy numbers such that each neuron can learn how a feature affects the production of the correct output from both the positive and negative sides. We propose a hybrid algorithm combining a gradient-based method and an evolutionary algorithm for training the PFDBM. Based on the novel learning model, we develop a deep neural network (DNN) for classifying normal passengers and potential attackers, and further develop an integrated DNN for identifying group attackers whose individual features are insufficient to reveal the abnormality. Experiments on data sets from Air China show that our approach provides much higher learning ability and classification accuracy than existing profilers. It is expected that the fuzzy deep learning approach can be adapted for a variety of complex pattern analysis tasks.

  4. Determination of the ion thermal diffusivity from neutron emission profiles in decay

    International Nuclear Information System (INIS)

    Sasao, M.; Adam, J.M.; Conroy, S.; Jarvis, O.N.; Marcus, F.B.; Sadler, G.; Belle, P. van

    1992-01-01

    Spatial profiles of neutron emission are routinely obtained at the Joint European Torus (JET) from line-integrated emissivities measured with a multi-channel instrument. It is shown that the manner in which the emission profiles relax following termination of strong heating with Neutral Beam Injection (NBI) permits the local thermal diffusivity (χ i ) to be obtained with an accuracy of about 20%. The radial profiles of χ i for small minor radius (r/a 2 /s for H-mode plasmas with plasma current I p = 3.1 MA and toroidal field B T = 2.3T. The experimental value of χ i is smallest for Z eff = 2.2 and increases weakly with increasing Z eff . The experimental results disagree by two orders of magnitude with predictions from an ion temperature gradient driven turbulence model. (author) 6 refs., 3 figs

  5. Policy required for entry of DNA profiles onto the National Forensic DNA Database of South Africa

    Directory of Open Access Journals (Sweden)

    Laura J. Heathfield

    2014-07-01

    Full Text Available The recent Criminal Law (Forensic Procedures Amendment Act (2013 provides a definition for forensic DNA profiles and, in so doing, states that medical information about an individual may not be revealed through a forensic DNA profile. Yet chromosomal abnormalities can exhibit as tri-allelic patterns on DNA profiles and such information can expose medical conditions such as Down syndrome. This short report highlights this concern and suggests a policy be created for the entering of such DNA profiles onto the National Forensic DNA database of South Africa.

  6. Quality control on the accuracy of the total Beta activity index in different sample matrices water

    International Nuclear Information System (INIS)

    Pujol, L.; Pablo, M. A. de; Payeras, J.

    2013-01-01

    The standard ISO/IEC 17025:2005 of general requirements for the technical competence of testing and calibration laboratories, provides that a laboratory shall have quality control procedures for monitoring the validity of tests and calibrations ago. In this paper, the experience of Isotopic Applications Laboratory (CEDEX) in controlling the accuracy rate of total beta activity in samples of drinking water, inland waters and marine waters is presented. (Author)

  7. Coping profiles, perceived stress and health-related behaviors: a cluster analysis approach.

    Science.gov (United States)

    Doron, Julie; Trouillet, Raphael; Maneveau, Anaïs; Ninot, Grégory; Neveu, Dorine

    2015-03-01

    Using cluster analytical procedure, this study aimed (i) to determine whether people could be differentiated on the basis of coping profiles (or unique combinations of coping strategies); and (ii) to examine the relationships between these profiles and perceived stress and health-related behaviors. A sample of 578 French students (345 females, 233 males; M(age)= 21.78, SD(age)= 2.21) completed the Perceived Stress Scale-14 ( Bruchon-Schweitzer, 2002), the Brief COPE ( Muller and Spitz, 2003) and a series of items measuring health-related behaviors. A two-phased cluster analytic procedure (i.e. hierarchical and non-hierarchical-k-means) was employed to derive clusters of coping strategy profiles. The results yielded four distinctive coping profiles: High Copers, Adaptive Copers, Avoidant Copers and Low Copers. The results showed that clusters differed significantly in perceived stress and health-related behaviors. High Copers and Avoidant Copers displayed higher levels of perceived stress and engaged more in unhealthy behavior, compared with Adaptive Copers and Low Copers who reported lower levels of stress and engaged more in healthy behaviors. These findings suggested that individuals' relative reliance on some strategies and de-emphasis on others may be a more advantageous way of understanding the manner in which individuals cope with stress. Therefore, cluster analysis approach may provide an advantage over more traditional statistical techniques by identifying distinct coping profiles that might best benefit from interventions. Future research should consider coping profiles to provide a deeper understanding of the relationships between coping strategies and health outcomes and to identify risk groups. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Declarative and Procedural Memory in Danish Speaking Children with Specific Language Impairment

    Science.gov (United States)

    Lum, Jarrad A. G.; Bleses, Dorthe

    2012-01-01

    It has been proposed that the language problems in specific language impairment (SLI) arise from basal ganglia abnormalities that lead to impairments with procedural and working memory but not declarative memory. In SLI, this profile of memory functioning has been hypothesized to underlie grammatical impairment but leave lexical knowledge…

  9. Application of modified analytical function for approximation and computer simulation of diffraction profile

    International Nuclear Information System (INIS)

    Marrero, S. I.; Turibus, S. N.; Assis, J. T. De; Monin, V. I.

    2011-01-01

    Data processing of the most of diffraction experiments is based on determination of diffraction line position and measurement of broadening of diffraction profile. High precision and digitalisation of these procedures can be resolved by approximation of experimental diffraction profiles by analytical functions. There are various functions for these purposes both simples, like Gauss function, but no suitable for wild range of experimental profiles and good approximating functions but complicated for practice using, like Vougt or PersonVII functions. Proposed analytical function is modified Cauchy function which uses two variable parameters allowing describing any experimental diffraction profile. In the presented paper modified function was applied for approximation of diffraction lines of steels after various physical and mechanical treatments and simulation of diffraction profiles applied for study of stress gradients and distortions of crystal structure. (Author)

  10. Continuous Water Vapor Profiles from Operational Ground-Based Active and Passive Remote Sensors

    Science.gov (United States)

    Turner, D. D.; Feltz, W. F.; Ferrare, R. A.

    2000-01-01

    The Atmospheric Radiation Measurement program's Southern Great Plains Cloud and Radiation Testbed site central facility near Lamont, Oklahoma, offers unique operational water vapor profiling capabilities, including active and passive remote sensors as well as traditional in situ radiosonde measurements. Remote sensing technologies include an automated Raman lidar and an automated Atmospheric Emitted Radiance Interferometer (AERI), which are able to retrieve water vapor profiles operationally through the lower troposphere throughout the diurnal cycle. Comparisons of these two water vapor remote sensing methods to each other and to radiosondes over an 8-month period are presented and discussed, highlighting the accuracy and limitations of each method. Additionally, the AERI is able to retrieve profiles of temperature while the Raman lidar is able to retrieve aerosol extinction profiles operationally. These data, coupled with hourly wind profiles from a 915-MHz wind profiler, provide complete specification of the state of the atmosphere in noncloudy skies. Several case studies illustrate the utility of these high temporal resolution measurements in the characterization of mesoscale features within a 3-day time period in which passage of a dryline, warm air advection, and cold front occurred.

  11. Effects of accuracy constraints on reach-to-grasp movements in cerebellar patients.

    Science.gov (United States)

    Rand, M K; Shimansky, Y; Stelmach, G E; Bracha, V; Bloedel, J R

    2000-11-01

    Reach-to-grasp movements of patients with pathology restricted to the cerebellum were compared with those of normal controls. Two types of paradigms with different accuracy constraints were used to examine whether cerebellar impairment disrupts the stereotypic relationship between arm transport and grip aperture and whether the variability of this relationship is altered when greater accuracy is required. The movements were made to either a vertical dowel or to a cross bar of a small cross. All subjects were asked to reach for either target at a fast but comfortable speed, grasp the object between the index finger and thumb, and lift it a short distance off the table. In terms of the relationship between arm transport and grip aperture, the control subjects showed a high consistency in grip aperture and wrist velocity profiles from trial to trial for movements to both the dowel and the cross. The relationship between the maximum velocity of the wrist and the time at which grip aperture was maximal during the reach was highly consistent throughout the experiment. In contrast, the time of maximum grip aperture and maximum wrist velocity of the cerebellar patients was quite variable from trial to trial, and the relationship of these measurements also varied considerably. These abnormalities were present regardless of the accuracy requirement. In addition, the cerebellar patients required a significantly longer time to grasp and lift the objects than the control subjects. Furthermore, the patients exhibited a greater grip aperture during reach than the controls. These data indicate that the cerebellum contributes substantially to the coordination of movements required to perform reach-to-grasp movements. Specifically, the cerebellum is critical for executing this behavior with a consistent, well-timed relationship between the transport and grasp components. This contribution is apparent even when accuracy demands are minimal.

  12. Data accuracy assessment using enterprise architecture

    Science.gov (United States)

    Närman, Per; Holm, Hannes; Johnson, Pontus; König, Johan; Chenine, Moustafa; Ekstedt, Mathias

    2011-02-01

    Errors in business processes result in poor data accuracy. This article proposes an architecture analysis method which utilises ArchiMate and the Probabilistic Relational Model formalism to model and analyse data accuracy. Since the resources available for architecture analysis are usually quite scarce, the method advocates interviews as the primary data collection technique. A case study demonstrates that the method yields correct data accuracy estimates and is more resource-efficient than a competing sampling-based data accuracy estimation method.

  13. Hospital discharge diagnostic and procedure codes for upper gastro-intestinal cancer: how accurate are they?

    Directory of Open Access Journals (Sweden)

    Stavrou Efty

    2012-09-01

    Full Text Available Abstract Background Population-level health administrative datasets such as hospital discharge data are used increasingly to evaluate health services and outcomes of care. However information about the accuracy of Australian discharge data in identifying cancer, associated procedures and comorbidity is limited. The Admitted Patients Data Collection (APDC is a census of inpatient hospital discharges in the state of New South Wales (NSW. Our aim was to assess the accuracy of the APDC in identifying upper gastro-intestinal (upper GI cancer cases, procedures for associated curative resection and comorbidities at the time of admission compared to data abstracted from medical records (the ‘gold standard’. Methods We reviewed the medical records of 240 patients with an incident upper GI cancer diagnosis derived from a clinical database in one NSW area health service from July 2006 to June 2007. Extracted case record data was matched to APDC discharge data to determine sensitivity, positive predictive value (PPV and agreement between the two data sources (κ-coefficient. Results The accuracy of the APDC diagnostic codes in identifying site-specific incident cancer ranged from 80-95% sensitivity. This was comparable to the accuracy of APDC procedure codes in identifying curative resection for upper GI cancer. PPV ranged from 42-80% for cancer diagnosis and 56-93% for curative surgery. Agreement between the data sources was >0.72 for most cancer diagnoses and curative resections. However, APDC discharge data was less accurate in reporting common comorbidities - for each condition, sensitivity ranged from 9-70%, whilst agreement ranged from κ = 0.64 for diabetes down to κ  Conclusions Identifying incident cases of upper GI cancer and curative resection from hospital administrative data is satisfactory but under-ascertained. Linkage of multiple population-health datasets is advisable to maximise case ascertainment and minimise false

  14. Validation of accuracy and stability of numerical simulation for 2-D heat transfer system by an entropy production approach

    Directory of Open Access Journals (Sweden)

    Brohi Ali Anwar

    2017-01-01

    Full Text Available The entropy production in 2-D heat transfer system has been analyzed systematically by using the finite volume method, to develop new criteria for the numerical simulation in case of multidimensional systems, with the aid of the CFD codes. The steady-state heat conduction problem has been investigated for entropy production, and the entropy production profile has been calculated based upon the current approach. From results for 2-D heat conduction, it can be found that the stability of entropy production profile exhibits a better agreement with the exact solution accordingly, and the current approach is effective for measuring the accuracy and stability of numerical simulations for heat transfer problems.

  15. Error Correction of Measured Unstructured Road Profiles Based on Accelerometer and Gyroscope Data

    Directory of Open Access Journals (Sweden)

    Jinhua Han

    2017-01-01

    Full Text Available This paper describes a noncontact acquisition system composed of several time synchronized laser height sensors, accelerometers, gyroscope, and so forth in order to collect the road profiles of vehicle riding on the unstructured roads. A method of correcting road profiles based on the accelerometer and gyroscope data is proposed to eliminate the adverse impacts of vehicle vibration and attitudes change. Because the power spectral density (PSD of gyro attitudes concentrates in the low frequency band, a method called frequency division is presented to divide the road profiles into two parts: high frequency part and low frequency part. The vibration error of road profiles is corrected by displacement data obtained through two times integration of measured acceleration data. After building the mathematical model between gyro attitudes and road profiles, the gyro attitudes signals are separated from low frequency road profile by the method of sliding block overlap based on correlation analysis. The accuracy and limitations of the system have been analyzed, and its validity has been verified by implementing the system on wheeled equipment for road profiles’ measuring of vehicle testing ground. The paper offers an accurate and practical approach to obtaining unstructured road profiles for road simulation test.

  16. Radial-rotation profile forming: A new processing technology of incremental sheet metal forming

    Science.gov (United States)

    Laue, Robert; Härtel, Sebastian; Awiszus, Birgit

    2018-05-01

    Incremental forming processes (i.e., spinning) of sheet metal blanks into cylindrical cups are suitable for lower lot sizes. The produced cups were frequently used as preforms to produce workpieces in further forming steps with additional functions like profiled hollow parts [1]. The incremental forming process radial-rotation profile forming has been developed to enable the production of profiled hollow parts with low sheet thinning and good geometrical accuracy. The two principal forming steps are the production of the preform by rotational swing-folding [2] and the subsequent radial profiling of the hollow part in one clamping position. The rotational swing-folding process is based on a combination of conventional spinning and swing-folding. Therefore, a round blank rotates on a profiled mandrel and due to the swinging of a cylindrical forming tool, the blank is formed to a cup with low sheet thinning. In addition, thickening results at the edge of the blank and wrinkling occurs. However, the wrinkles are formed into the indentation of the profiled mandrel and can be reshaped as an advantage in the second process step, the radial profiling. Due to the rotation and continuous radial feed of a profiled forming tool to the profiled mandrel, the axial profile is formed in the second process step. Because of the minor relative movement in axial direction between tool and blank, low sheet thinning occurs. This is an advantage of the principle of the process.

  17. Examining the accuracy of the infinite order sudden approximation using sensitivity analysis

    Science.gov (United States)

    Eno, Larry; Rabitz, Herschel

    1981-08-01

    A method is developed for assessing the accuracy of scattering observables calculated within the framework of the infinite order sudden (IOS) approximation. In particular, we focus on the energy sudden assumption of the IOS method and our approach involves the determination of the sensitivity of the IOS scattering matrix SIOS with respect to a parameter which reintroduces the internal energy operator ?0 into the IOS Hamiltonian. This procedure is an example of sensitivity analysis of missing model components (?0 in this case) in the reference Hamiltonian. In contrast to simple first-order perturbation theory a finite result is obtained for the effect of ?0 on SIOS. As an illustration, our method of analysis is applied to integral state-to-state cross sections for the scattering of an atom and rigid rotor. Results are generated within the He+H2 system and a comparison is made between IOS and coupled states cross sections and the corresponding IOS sensitivities. It is found that the sensitivity coefficients are very useful indicators of the accuracy of the IOS results. Finally, further developments and applications are discussed.

  18. Velocity measurement accuracy in optical microhemodynamics: experiment and simulation

    International Nuclear Information System (INIS)

    Chayer, Boris; Cloutier, Guy; L Pitts, Katie; Fenech, Marianne

    2012-01-01

    Micro particle image velocimetry (µPIV) is a common method to assess flow behavior in blood microvessels in vitro as well as in vivo. The use of red blood cells (RBCs) as tracer particles, as generally considered in vivo, creates a large depth of correlation (DOC), even as large as the vessel itself, which decreases the accuracy of the method. The limitations of µPIV for blood flow measurements based on RBC tracking still have to be evaluated. In this study, in vitro and in silico models were used to understand the effect of the DOC on blood flow measurements using µPIV RBC tracer particles. We therefore employed a µPIV technique to assess blood flow in a 15 µm radius glass tube with a high-speed CMOS camera. The tube was perfused with a sample of 40% hematocrit blood. The flow measured by a cross-correlating speckle tracking technique was compared to the flow rate of the pump. In addition, a three-dimensional mechanical RBC-flow model was used to simulate optical moving speckle at 20% and 40% hematocrits, in 15 and 20 µm radius circular tubes, at different focus planes, flow rates and for various velocity profile shapes. The velocity profiles extracted from the simulated pictures were compared with good agreement with the corresponding velocity profiles implemented in the mechanical model. The flow rates from both the in vitro flow phantom and the mathematical model were accurately measured with less than 10% errors. Simulation results demonstrated that the hematocrit (paired t tests, p = 0.5) and the tube radius (p = 0.1) do not influence the precision of the measured flow rate, whereas the shape of the velocity profile (p < 0.001) and the location of the focus plane (p < 0.001) do, as indicated by measured errors ranging from 3% to 97%. In conclusion, the use of RBCs as tracer particles makes a large DOC and affects the image processing required to estimate the flow velocities. We found that the current µPIV method is acceptable to estimate the flow rate

  19. Wave induced extreme hull girder loads on containerships

    DEFF Research Database (Denmark)

    Jensen, Jørgen Juncher; Pedersen, Preben Terndrup; Shi, Bill

    2009-01-01

    This paper provides simple but rational procedures for prediction of extreme wave – induced sectional hull girder forces with reasonable engineering accuracy. The procedures take into account main ship hull characteristics such as: length, breadth, draught, block coefficient, bow flare coefficient......, forward speed and hull flexibility. The vertical hull girder loads are evaluated for specific operational profiles. Firstly a quadratic strip theory is presented which can give separate predictions for the hogging and sagging bending moments and shear forces and for hull girder loads. Then this procedure...... is based on rational methods it can be applied for novel single hull ship types not presently covered by the rules of the classification societies or to account for specific operational profiles....

  20. Systematic literature review and meta-analysis of diagnostic test accuracy in Alzheimer's disease and other dementia using autopsy as standard of truth.

    Science.gov (United States)

    Cure, Sandrine; Abrams, Keith; Belger, Mark; Dell'agnello, Grazzia; Happich, Michael

    2014-01-01

    Early diagnosis of Alzheimer's disease (AD) is crucial to implement the latest treatment strategies and management of AD symptoms. Diagnostic procedures play a major role in this detection process but evidence on their respective accuracy is still limited. To conduct a systematic literature on the sensitivity and specificity of different test modalities to identify AD patients and perform meta-analyses on the test accuracy values of studies focusing on autopsy-confirmation as the standard of truth. The systematic review identified all English papers published between 1984 and 2011 on diagnostic imaging tests and cerebrospinal fluid biomarkers including results on the newest technologies currently investigated in this area. Meta-analyses using bivariate fixed and random-effect models and hierarchical summary receiver operating curve (HSROC) random-effect model were applied. Out of the 1,189 records, 20 publications were identified to report the accuracy of diagnostic tests in distinguishing autopsy-confirmed AD patients from other dementia types and healthy controls. Looking at all tests and comparator populations together, sensitivity was calculated at 85.4% (95% confidence interval [CI]: 80.9%-90.0%) and specificity at 77.7% (95% CI: 70.2%-85.1%). The area under the HSROC curve was 0.88. Sensitivity and specificity values were higher for imaging procedures, and slightly lower for CSF biomarkers. Test-specific random-effect models could not be calculated due to the small number of studies. The review and meta-analysis point to a slight advantage of imaging procedures in correctly detecting AD patients but also highlight the limited evidence on autopsy-confirmations and heterogeneity in study designs.

  1. A Multimode Adaptive Pushover Procedure for Seismic Assessment of Integral Bridges

    Directory of Open Access Journals (Sweden)

    Ehsan Mohtashami

    2013-01-01

    Full Text Available This paper presents a new adaptive pushover procedure to account for the effect of higher modes in order to accurately estimate the seismic response of bridges. The effect of higher modes is considered by introducing a minimum value for the total effective modal mass. The proposed method employs enough number of modes to ensure that the defined total effective modal mass participates in all increments of the pushover loading. An adaptive demand curve is also developed for assessment of the seismic demand. The efficiency and robustness of the proposed method are demonstrated by conducting a parametric study. The analysis includes 18 four-span integral bridges with various heights of piers. The inelastic response history analysis is employed as reference solution in this study. Numerical results indicate excellent accuracy of the proposed method in assessment of the seismic response. For most bridges investigated in this study, the difference between the estimated response of the proposed method and the inelastic response history analysis is less than 25% for displacements and 10% for internal forces. This indicates a very good accuracy compared to available pushover procedures in the literature. The proposed method is therefore recommended to be applied to the seismic performance evaluation of integral bridges for engineering applications.

  2. A simplified test procedure for determining the effectiveness of adsorbents for the removal of methyl iodide

    International Nuclear Information System (INIS)

    Underhill, D.W.

    1993-01-01

    ASTM Test Procedure D3803 measures the ability of nuclear-grade carbon to remove methyl iodide from a stream of humidified air. This test, unlike all the other procedures developed by ASTM Committee D28, has evolved to become extremely complex. The intricacy of this test as well as the great difficulty in obtaining inter-laboratory agreement, creates doubt as tot the actual meaning of the results. Here a far simpler test system is described in which thermodynamic principles are used to maintain a constant, reproducible test procedure. This paper describes a system implementing these elements, its cost to build, and the factors affecting its accuracy. 11 refs., 1 fig

  3. Sonography of acute appendicitis in pregnant women: diagnostic accuracy by the stage of gestation

    International Nuclear Information System (INIS)

    Kim, Sam Soo; Lee, Sang Wook; Rho, Myung Ho

    2004-01-01

    To evaluate the diagnostic accuracy of a diagnosis of acute appendicitis in pregnant women according to the trimester. A retrospective review was performed on 103 pregnant women who underwent sonography with clinically suspected acute appendicitis. The sonographic technique used involved either the graded compression or a non-compression method. All the sonograms were obtained after changing the patient's position and identifying the diseased appendix. The criterion for a sonographic diagnosis of acute appendicitis was the visualization of a non-compressible appendix with a maximal diameter ≥ 6 mm. The sonographic findings were correlated with the surgical findings and clinical follow-up. Acute appendicitis was confirmed by both the surgical and pathological findings in 48 out of 103 pregnant women. Ultrasound established the diagnosis in 34 of the 48 patients with proven appendicitis. There were false-positives in 2 patients and false-negatives in 14 patients. Among the 55 patients who had a normal appendix, 30 patients improved at the clinical follow-up and 25 patients had other intra-abdominal disorders. The diagnostic accuracy of the ultrasound was 94% in the first trimester, 81% in the second trimester, and 76% in the third trimester. The overall accuracy was found to be 84%, with a 71% sensitivity and a 96% specificity. No significant difference was found in the diagnostic accuracy of the ultrasound according to the trimester in which the acute appendicitis occurred. Therefore, regardless of the stage of gestation, sonography is a valuable procedure for diagnosing acute appendicitis

  4. Improving shuffler assay accuracy

    International Nuclear Information System (INIS)

    Rinard, P.M.

    1995-01-01

    Drums of uranium waste should be disposed of in an economical and environmentally sound manner. The most accurate possible assays of the uranium masses in the drums are required for proper disposal. The accuracies of assays from a shuffler are affected by the type of matrix material in the drums. Non-hydrogenous matrices have little effect on neutron transport and accuracies are very good. If self-shielding is known to be a minor problem, good accuracies are also obtained with hydrogenous matrices when a polyethylene sleeve is placed around the drums. But for those cases where self-shielding may be a problem, matrices are hydrogenous, and uranium distributions are non-uniform throughout the drums, the accuracies are degraded. They can be greatly improved by determining the distributions of the uranium and then applying correction factors based on the distributions. This paper describes a technique for determining uranium distributions by using the neutron count rates in detector banks around the waste drum and solving a set of overdetermined linear equations. Other approaches were studied to determine the distributions and are described briefly. Implementation of this correction is anticipated on an existing shuffler next year

  5. Accuracy of genomic selection for alfalfa biomass yield in different reference populations.

    Science.gov (United States)

    Annicchiarico, Paolo; Nazzicari, Nelson; Li, Xuehui; Wei, Yanling; Pecetti, Luciano; Brummer, E Charles

    2015-12-01

    Genomic selection based on genotyping-by-sequencing (GBS) data could accelerate alfalfa yield gains, if it displayed moderate ability to predict parent breeding values. Its interest would be enhanced by predicting ability also for germplasm/reference populations other than those for which it was defined. Predicting accuracy may be influenced by statistical models, SNP calling procedures and missing data imputation strategies. Landrace and variety material from two genetically-contrasting reference populations, i.e., 124 elite genotypes adapted to the Po Valley (sub-continental climate; PV population) and 154 genotypes adapted to Mediterranean-climate environments (Me population), were genotyped by GBS and phenotyped in separate environments for dry matter yield of their dense-planted half-sib progenies. Both populations showed no sub-population genetic structure. Predictive accuracy was higher by joint rather than separate SNP calling for the two data sets, and using random forest imputation of missing data. Highest accuracy was obtained using Support Vector Regression (SVR) for PV, and Ridge Regression BLUP and SVR for Me germplasm. Bayesian methods (Bayes A, Bayes B and Bayesian Lasso) tended to be less accurate. Random Forest Regression was the least accurate model. Accuracy attained about 0.35 for Me in the range of 0.30-0.50 missing data, and 0.32 for PV at 0.50 missing data, using at least 10,000 SNP markers. Cross-population predictions based on a smaller subset of common SNPs implied a relative loss of accuracy of about 25% for Me and 30% for PV. Genome-wide association analyses based on large subsets of M. truncatula-aligned markers revealed many SNPs with modest association with yield, and some genome areas hosting putative QTLs. A comparison of genomic vs. conventional selection for parent breeding value assuming 1-year vs. 5-year selection cycles, respectively, indicated over three-fold greater predicted yield gain per unit time for genomic selection

  6. LASL lens design procedure: simple, fast, precise, versatile

    International Nuclear Information System (INIS)

    Brixner, B.

    1978-11-01

    The Los Alamos Scientific Laboratory general-purpose lens design procedure optimizes specific lens prescriptions to obtain the smallest possible image spots and therefore near-spherical wave fronts of light converging on all images in the field of view. Optical image errors are analyzed in much the same way that they are measured on the optical bench. This lens design method is made possible by using the full capabilities of large electronic computers. First, the performance of the whole lens is sampled with many precisely traced skew rays. Next, lens performance is analyzed with spot diagrams generated by the many rays. Third, lens performance is optimized with a least squares system aimed at reducing all image errors to zero. This statistical approach to lens design uses skew rays and precisely measured ray deviations from ideal image points to achieve greater accuracy than was possible with the classical procedure, which is based on approximate expressions derived from simplified ray traces developed for pencil-and-paper calculations

  7. Whole-body profile scanner for in vivo quantitative activity measurement

    International Nuclear Information System (INIS)

    Bergmann, H.

    1978-01-01

    A whole-body profile scanner has been developed by fitting parallel slit collimators to a shadow shield whole-body counter. Sensitivity, uniformity and resolution measurements were performed using a number of different counting conditions. It is shown that improved accuracy of activity measurements is obtained by using a wide window counting technique for low and medium energy gamma emitters (99m Tc, 131 I), whereas a photopeak window should be used for high energy gamma emitters (47 Ca). Due to the finite spatial resolution of the system a systematic error in evaluating regional activities from the counting rate profile occurs which is characterized by a spatial spillover factor. The spatial spillover factor is measured and is subsequently used to calculate the error on basis of a simple model. It is shown that only small errors are caused by spatial spillover when the length of a region is at least three times the full width half maximum of the point spread function. Applying the above mentioned simple rules it is concluded that profile scanning is a sensitive and accurate technique for activity measurements in vivo. Two examples of clinical applications (measurement of bone accretion rates of calcium and Tc-pyrophosphate, regional radioiodine retention in patients with thyroid carcinoma) and a review of the papers on profile scanning demonstrate the types of investigations in which profile scanning is superior to alternative techniques. (author)

  8. Nonparametric bootstrap procedures for predictive inference based on recursive estimation schemes

    OpenAIRE

    Corradi, Valentina; Swanson, Norman R.

    2005-01-01

    Our objectives in this paper are twofold. First, we introduce block bootstrap techniques that are (first order) valid in recursive estimation frameworks. Thereafter, we present two examples where predictive accuracy tests are made operational using our new bootstrap procedures. In one application, we outline a consistent test for out-of-sample nonlinear Granger causality, and in the other we outline a test for selecting amongst multiple alternative forecasting models, all of which are possibl...

  9. Refinement procedure for the image alignment in high-resolution electron tomography.

    Science.gov (United States)

    Houben, L; Bar Sadan, M

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Accuracy and Numerical Stabilty Analysis of Lattice Boltzmann Method with Multiple Relaxation Time for Incompressible Flows

    Science.gov (United States)

    Pradipto; Purqon, Acep

    2017-07-01

    Lattice Boltzmann Method (LBM) is the novel method for simulating fluid dynamics. Nowadays, the application of LBM ranges from the incompressible flow, flow in the porous medium, until microflows. The common collision model of LBM is the BGK with a constant single relaxation time τ. However, BGK suffers from numerical instabilities. These instabilities could be eliminated by implementing LBM with multiple relaxation time. Both of those scheme have implemented for incompressible 2 dimensions lid-driven cavity. The stability analysis has done by finding the maximum Reynolds number and velocity for converged simulations. The accuracy analysis is done by comparing the velocity profile with the benchmark results from Ghia, et al and calculating the net velocity flux. The tests concluded that LBM with MRT are more stable than BGK, and have a similar accuracy. The maximum Reynolds number that converges for BGK is 3200 and 7500 for MRT respectively.

  11. Office hysteroscopic-guided selective tubal chromopertubation: acceptability, feasibility and diagnostic accuracy of this new diagnostic non-invasive technique in infertile women.

    Science.gov (United States)

    Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice

    2018-06-01

    The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.

  12. Model etch profiles for ion energy distribution functions in an inductively coupled plasma reactor

    International Nuclear Information System (INIS)

    Chen, W.; Abraham-Shrauner, B.; Woodworth, J.R.

    1999-01-01

    Rectangular trench profiles are modeled with analytic etch rates determined from measured ion distribution functions. The pattern transfer step for this plasma etch is for trilayer lithography. Argon and chlorine angular ion energy distribution functions measured by a spherical collector ring analyzer are fit to a sum of drifting Maxwellian velocity distribution functions with anisotropic temperatures. The fit of the model ion distribution functions by a simulated annealing optimization procedure converges adequately for only two drifting Maxwellians. The etch rates are proportional to analytic expressions for the ion energy flux. Numerical computation of the etch profiles by integration of the characteristic equations for profile points and connection of the profiles points is efficient. copyright 1999 American Vacuum Society

  13. A procedure for the improvement in the determination of a TXRF spectrometer sensitivity curve

    International Nuclear Information System (INIS)

    Bennun, Leonardo; Sanhueza, Vilma

    2010-01-01

    A simple procedure is proposed to determine the total reflection X-ray fluorescence (TXRF) spectrometer sensitivity curve; this procedure provides better accuracy and exactitude than the standard established method. It uses individual pure substances instead of the use of vendor-certified values of reference calibration standards, which are expensive and lack any method to check their quality. This method avoids problems like uncertainties in the determination of the sensitivity curve according to different standards. It also avoids the need for validation studies between different techniques, in order to assure the quality of their TXRF results. (author)

  14. Nuclear data for fission reactor core design and safety analysis: Requirements and status of accuracy of nuclear data

    International Nuclear Information System (INIS)

    Rowlands, J.L.

    1984-01-01

    The types of nuclear data required for fission reactor design and safety analysis, and the ways in which the data are represented and approximated for use in reactor calculations, are summarised first. The relative importance of different items of nuclear data in the prediction of reactor parameters is described and ways of investigating the accuracy of these data by evaluating related integral measurements are discussed. The use of sensitivity analysis, together with estimates of the uncertainties in nuclear data and relevant integral measurements, in assessing the accuracy of prediction of reactor parameters is described. The inverse procedure for deciding nuclear data requirements from the target accuracies for prediction of reactor parameters follows on from this. The need for assessments of the uncertainties in nuclear data evaluations and the form of the uncertainty information is discussed. The status of the accuracies of predictions and nuclear data requirements are then summarised. The reactor parameters considered include: (a) Criticality conditions, conversion and burn-up effects. (b) Energy production and deposition, decay heating, irradiation damage, dosimetry and induced radioactivity. (c) Kinetics characteristics and control, including temperature, power and coolant density coefficients, delayed neutrons and control absorbers. (author)

  15. Validity of diagnoses, procedures, and laboratory data in Japanese administrative data.

    Science.gov (United States)

    Yamana, Hayato; Moriwaki, Mutsuko; Horiguchi, Hiromasa; Kodan, Mariko; Fushimi, Kiyohide; Yasunaga, Hideo

    2017-10-01

    Validation of recorded data is a prerequisite for studies that utilize administrative databases. The present study evaluated the validity of diagnoses and procedure records in the Japanese Diagnosis Procedure Combination (DPC) data, along with laboratory test results in the newly-introduced Standardized Structured Medical Record Information Exchange (SS-MIX) data. Between November 2015 and February 2016, we conducted chart reviews of 315 patients hospitalized between April 2014 and March 2015 in four middle-sized acute-care hospitals in Shizuoka, Kochi, Fukuoka, and Saga Prefectures and used them as reference standards. The sensitivity and specificity of DPC data in identifying 16 diseases and 10 common procedures were identified. The accuracy of SS-MIX data for 13 laboratory test results was also examined. The specificity of diagnoses in the DPC data exceeded 96%, while the sensitivity was below 50% for seven diseases and variable across diseases. When limited to primary diagnoses, the sensitivity and specificity were 78.9% and 93.2%, respectively. The sensitivity of procedure records exceeded 90% for six procedures, and the specificity exceeded 90% for nine procedures. Agreement between the SS-MIX data and the chart reviews was above 95% for all 13 items. The validity of diagnoses and procedure records in the DPC data and laboratory results in the SS-MIX data was high in general, supporting their use in future studies. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  16. RASS sound speed profile (SSP) measurements for use in outdoor sound propagation models

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, S G [Physics Department, University of Auckland (New Zealand); Huenerbein, S v; Waddington, D [Research Institute for the Built and Human Environment, University of Salford (United Kingdom)], E-mail: s.vonhunerbein@salford.ac.uk

    2008-05-01

    The performance of outdoor sound propagation models depends to a great extent on meteorological input parameters. In an effort to improve speed and accuracy, model output synthetic sound speed profiles (SSP) are commonly used depending on meteorological classification schemes. In order to use SSP measured by RASS in outdoor sound propagation models, the complex profiles need to be simplified. In this paper we extend an investigation on the spatial and temporal characteristics of the meteorological data set required to yield adequate comparisons between models and field measurements, so that the models can be fairly judged. Vertical SSP from RASS, SODAR wind profiles as well as mast wind and temperature data from a flat terrain site and measured over a period of several months are used to evaluate applicability of the logarithmic approximation for a stability classification scheme proposed by the HARMONOISE working group.

  17. RASS sound speed profile (SSP) measurements for use in outdoor sound propagation models

    International Nuclear Information System (INIS)

    Bradley, S G; Huenerbein, S v; Waddington, D

    2008-01-01

    The performance of outdoor sound propagation models depends to a great extent on meteorological input parameters. In an effort to improve speed and accuracy, model output synthetic sound speed profiles (SSP) are commonly used depending on meteorological classification schemes. In order to use SSP measured by RASS in outdoor sound propagation models, the complex profiles need to be simplified. In this paper we extend an investigation on the spatial and temporal characteristics of the meteorological data set required to yield adequate comparisons between models and field measurements, so that the models can be fairly judged. Vertical SSP from RASS, SODAR wind profiles as well as mast wind and temperature data from a flat terrain site and measured over a period of several months are used to evaluate applicability of the logarithmic approximation for a stability classification scheme proposed by the HARMONOISE working group

  18. Significant improvement of accuracy and precision in the determination of trace rare earths by fluorescence analysis

    International Nuclear Information System (INIS)

    Ozawa, L.; Hersh, H.N.

    1976-01-01

    Most of the rare earths in yttrium, gadolinium and lanthanum oxides emit characteristic fluorescent line spectra under irradiation with photons, electrons and x rays. The sensitivity and selectivity of the rare earth fluorescences are high enough to determine the trace amounts (0.01 to 100 ppM) of rare earths. The absolute fluorescent intensities of solids, however, are markedly affected by the synthesis procedure, level of contamination and crystal perfection, resulting in poor accuracy and low precision for the method (larger than 50 percent error). Special care in preparation of the samples is required to obtain good accuracy and precision. It is found that the accuracy and precision for the determination of trace (less than 10 ppM) rare earths by fluorescence analysis improved significantly, while still maintaining the sensitivity, when the determination is made by comparing the ratio of the fluorescent intensities of the trace rare earths to that of a deliberately added rare earth as reference. The variation in the absolute fluorescent intensity remains, but is compensated for by measuring the fluorescent line intensity ratio. Consequently, the determination of trace rare earths (with less than 3 percent error) is easily made by a photoluminescence technique in which the rare earths are excited directly by photons. Accuracy is still maintained when the absolute fluorescent intensity is reduced by 50 percent through contamination by Ni, Fe, Mn or Pb (about 100 ppM). Determination accuracy is also improved for fluorescence analysis by electron excitation and x-ray excitation. For some rare earths, however, accuracy by these techniques is reduced because indirect excitation mechanisms are involved. The excitation mechanisms and the interferences between rare earths are also reported

  19. Autogenous bone grafts in the esthetic zone: optimizing the procedure using piezosurgery.

    Science.gov (United States)

    Majewski, Piotr

    2012-12-01

    Soft and hard tissue defects pose a therapeutic challenge in modern implant dentistry. There are a multitude of surgical techniques available, and it is necessary to match the problem with the solution. This report describes the reconstruction of the alveolar ridge in the esthetic zone with the help of autogenous bone blocks harvested from the chin that were shaped to fit and stabilized at the recipient site. The procedures were performed using Piezosurgery, which made it possible to introduce surgical modifications and had a significant impact on the accuracy of the procedure. An observation period of 2 to 7 years showed positive stable results for treatment in terms of function and esthetics.

  20. A Procedure for Identification of Appropriate State Space and ARIMA Models Based on Time-Series Cross-Validation

    Directory of Open Access Journals (Sweden)

    Patrícia Ramos

    2016-11-01

    Full Text Available In this work, a cross-validation procedure is used to identify an appropriate Autoregressive Integrated Moving Average model and an appropriate state space model for a time series. A minimum size for the training set is specified. The procedure is based on one-step forecasts and uses different training sets, each containing one more observation than the previous one. All possible state space models and all ARIMA models where the orders are allowed to range reasonably are fitted considering raw data and log-transformed data with regular differencing (up to second order differences and, if the time series is seasonal, seasonal differencing (up to first order differences. The value of root mean squared error for each model is calculated averaging the one-step forecasts obtained. The model which has the lowest root mean squared error value and passes the Ljung–Box test using all of the available data with a reasonable significance level is selected among all the ARIMA and state space models considered. The procedure is exemplified in this paper with a case study of retail sales of different categories of women’s footwear from a Portuguese retailer, and its accuracy is compared with three reliable forecasting approaches. The results show that our procedure consistently forecasts more accurately than the other approaches and the improvements in the accuracy are significant.

  1. Considerations for automated machine learning in clinical metabolic profiling: Altered homocysteine plasma concentration associated with metformin exposure.

    Science.gov (United States)

    Orlenko, Alena; Moore, Jason H; Orzechowski, Patryk; Olson, Randal S; Cairns, Junmei; Caraballo, Pedro J; Weinshilboum, Richard M; Wang, Liewei; Breitenstein, Matthew K

    2018-01-01

    With the maturation of metabolomics science and proliferation of biobanks, clinical metabolic profiling is an increasingly opportunistic frontier for advancing translational clinical research. Automated Machine Learning (AutoML) approaches provide exciting opportunity to guide feature selection in agnostic metabolic profiling endeavors, where potentially thousands of independent data points must be evaluated. In previous research, AutoML using high-dimensional data of varying types has been demonstrably robust, outperforming traditional approaches. However, considerations for application in clinical metabolic profiling remain to be evaluated. Particularly, regarding the robustness of AutoML to identify and adjust for common clinical confounders. In this study, we present a focused case study regarding AutoML considerations for using the Tree-Based Optimization Tool (TPOT) in metabolic profiling of exposure to metformin in a biobank cohort. First, we propose a tandem rank-accuracy measure to guide agnostic feature selection and corresponding threshold determination in clinical metabolic profiling endeavors. Second, while AutoML, using default parameters, demonstrated potential to lack sensitivity to low-effect confounding clinical covariates, we demonstrated residual training and adjustment of metabolite features as an easily applicable approach to ensure AutoML adjustment for potential confounding characteristics. Finally, we present increased homocysteine with long-term exposure to metformin as a potentially novel, non-replicated metabolite association suggested by TPOT; an association not identified in parallel clinical metabolic profiling endeavors. While warranting independent replication, our tandem rank-accuracy measure suggests homocysteine to be the metabolite feature with largest effect, and corresponding priority for further translational clinical research. Residual training and adjustment for a potential confounding effect by BMI only slightly modified

  2. Profile parameters of wheelset detection for high speed freight train

    Science.gov (United States)

    Yang, Kai; Ma, Li; Gao, Xiaorong; Wang, Li

    2012-04-01

    Because of freight train, in China, transports goods on railway freight line throughout the country, it does not depart from or return to engine shed during a long phase, thus we cannot monitor the quality of wheel set effectively. This paper provides a system which uses leaser and high speed camera, applies no-contact light section technology to get precise wheel set profile parameters. The paper employs clamping-track method to avoid complex railway ballast modification project. And detailed descript an improved image-tracking algorithm to extract central line from profile curve. For getting one pixel width and continuous line of the profile curve, uses local gray maximum points as direction control points to direct tracking direction. The results based on practical experiment show the system adapted to detection environment of high speed and high vibration, and it can effectively detect the wheelset geometric parameters with high accuracy. The system fills the gaps in wheel set detection for freight train in main line and has an enlightening function on monitoring the quality of wheel set.

  3. Geoid undulation accuracy

    Science.gov (United States)

    Rapp, Richard H.

    1993-01-01

    The determination of the geoid and equipotential surface of the Earth's gravity field, has long been of interest to geodesists and oceanographers. The geoid provides a surface to which the actual ocean surface can be compared with the differences implying information on the circulation patterns of the oceans. For use in oceanographic applications the geoid is ideally needed to a high accuracy and to a high resolution. There are applications that require geoid undulation information to an accuracy of +/- 10 cm with a resolution of 50 km. We are far from this goal today but substantial improvement in geoid determination has been made. In 1979 the cumulative geoid undulation error to spherical harmonic degree 20 was +/- 1.4 m for the GEM10 potential coefficient model. Today the corresponding value has been reduced to +/- 25 cm for GEM-T3 or +/- 11 cm for the OSU91A model. Similar improvements are noted by harmonic degree (wave-length) and in resolution. Potential coefficient models now exist to degree 360 based on a combination of data types. This paper discusses the accuracy changes that have taken place in the past 12 years in the determination of geoid undulations.

  4. Accuracy improvement in a calibration test bench for accelerometers by a vision system

    International Nuclear Information System (INIS)

    D’Emilia, Giulio; Di Gasbarro, David; Gaspari, Antonella; Natale, Emanuela

    2016-01-01

    A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

  5. Accuracy improvement in a calibration test bench for accelerometers by a vision system

    Energy Technology Data Exchange (ETDEWEB)

    D’Emilia, Giulio, E-mail: giulio.demilia@univaq.it; Di Gasbarro, David, E-mail: david.digasbarro@graduate.univaq.it; Gaspari, Antonella, E-mail: antonella.gaspari@graduate.univaq.it; Natale, Emanuela, E-mail: emanuela.natale@univaq.it [University of L’Aquila, Department of Industrial and Information Engineering and Economics (DIIIE), via G. Gronchi, 18, 67100 L’Aquila (Italy)

    2016-06-28

    A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

  6. Evaluation of accuracy of intra operative imprint cytology for detection of breast lesions

    International Nuclear Information System (INIS)

    Mahmood, Z.; Shahbaz, A.; Qureshi, A.; Aziz, N.; Niazi, S.; Qureshi, S.; Bukhari, M.H.

    2010-01-01

    Objective: To determine the accuracy of imprint cytology as an intraoperative diagnostic procedure for breast lesions with histopathological correlation. Materials and Methods: This was a descriptive study on 40 cases of breast lesions comprising of inflammatory, benign and malignant lesions including their margins etc. It was conducted at King Edward Medical University, Lahore in collaboration with all Surgical Departments of Mayo Hospital. Relevant clinical data was recorded in a proforma. Both touch and scrape imprints were prepared from all the lesions and stained with May-Grunwaled Giemsa and Haematoxylin and Eosin stains. The imprints were subsequently compared with histopathology sections. Results: When we used atypical cases as negative both touch and scrape imprints gave sensitivity, specificity, positive predictive value, negative predictive value and accuracy at 100%. However when we used cases with atypia as positive, sensitivity and negative predictive value were 100% with both touch and scrape imprints. Specificity, positive predictive value and accuracy were 71%, 86%, 85.5% respectively with touch imprints and 78%, 89%, 89% respectively with scrape imprints. No diagnostic difference was noted between the results of both stains. All the imprints were well correlated with histopathological diagnosis. Conclusion: Imprint cytology is an accurate and simple intraoperative method for diagnosing breast lesions. It can provide the surgeons with information regarding immediate clinical and surgical interventions. (author)

  7. Accuracy, convergence and stability of finite element CFD algorithms

    International Nuclear Information System (INIS)

    Baker, A.J.; Iannelli, G.S.; Noronha, W.P.

    1989-01-01

    The requirement for artificial dissipation is well understood for shock-capturing CFD procedures in aerodynamics. However, numerical diffusion is widely utilized across the board in Navier-Stokes CFD algorithms, ranging from incompressible through supersonic flow applications. The Taylor weak statement (TWS) theory is applicable to any conservation law system containing an evolutionary component, wherein the analytical modifications becomes functionally dependent on the Jacobian of the corresponding equation system flux vector. The TWS algorithm is developed for a range of fluid mechanics conservation law systems including incompressible Navier-Stokes, depth-averaged free surface hydrodynamic Navier-Stokes, and the compressible Euler and Navier-Stokes equations. This paper presents the TWS statement for the problem class range and highlights the important theoretical issues of accuracy, convergence and stability. Numerical results for a variety of benchmark problems are presented to document key features. 8 refs

  8. Retrieval of vertical concentration profiles from OSIRIS UV-visible limb spectra

    International Nuclear Information System (INIS)

    Strong, K.; Joseph, B.M.; Dosanjh, R.; McDade, I.C.; McLinden, C.A.; McConnell, J.C.; Stegman, J.; Murtagh, D.P.; Llewellyn, E.J.

    2002-01-01

    The OSIRIS instrument, launched on the Odin satellite in February 2001, includes an optical spectrograph that will record UV-visible spectra of sunlight scattered from the limb over a range of tangent heights. These spectra will be used to retrieve vertical profiles of ozone, NO 2 , OC1O, BrO, NO 3 , O 2 , and aerosols, for the investigation of both stratospheric and mesospheric processes, particularly those related to ozone chemistry. In this work, the retrieval of vertical profiles of trace-gas concentrations from OSIRIS limb-radiance spectra is described. A forward model has been developed to simulate these spectra, and it consists of a single-scattering radiative-transfer model with partial spherical geometry, trace-gas absorption, Mic scattering by stratospheric aerosols, a Lambertian surface contribution, and OSIRIS instrument response and noise. Number-density profiles have been retrieved by using optimal estimation (OE) to combine an a priori profile with the information from sets of synthetic 'measurements'. For ozone, OE has been applied both to limb radiances at one or more discrete wavelengths and to effective-column abundances retrieved over a broad spectral range using differential optical absorption spectroscopy (DOAS). The results suggest that, between 15 and 35 km, ozone number densities can be retrieved to 10% accuracy or better on 1 and 2 km grids and to 5% on a 5 km grid. The combined DOAS-OE approach has also been used to retrieve NO 2 number densities, yielding 13% accuracy or better for altitudes from 18 to 36 km (in a 2 km grid. Differential optical absorption spectroscopy - optimal estimation retrievals of BrO and OC1O reproduce the true profiles above 15 km in the noise-free case, but the quality of the retrievals is highly sensitive to noise on the simulated OSIRIS spectra because of the weak absorption of these two gases. The development of inversion methods for the retrieval of trace-gas concentrations from OSIRIS spectra is continuing

  9. Procedure of trace element analysis in oyster tissues by using X-ray fluorescence

    International Nuclear Information System (INIS)

    Vo Thi Tuong Hanh; Dinh Thi Bich Lieu; Dinh Thien Lam and Nguyen Manh Hung

    2004-01-01

    The procedure of trace element analysis such as Ca, Mn, Fe, Zn, Cu, Pb in molluscs (oyster tissues) was established by using X-ray fluorescence techniques. The procedure was investigated from the sample collection, drying, ashing ratio to the analytical techniques by using Cd-109, detector Si (Li) and the peak processing MCAPLUS program was applied for this study. The procedure is based on direct comparison with certified concentrations of international standard reference SRM 1566b Oyster Tissue of National Institute of Standards and Technology, Department of commerce, United States of America for Ca, Mn, Fe, Zn, Cu and the Standard Addition Methods for Pb. The accuracy of the Standard Addition Methods was estimated by CRM281 Rye Grass of Community Bureau of Reference-BCR, European Commission. The results of 10 samples which were collected from several markets in Hanoi are shown. (author)

  10. Accuracy of fibula reconstruction using patient-specific CAD/CAM reconstruction plates and dental implants : A new modality for functional reconstruction of mandibular defects

    NARCIS (Netherlands)

    Schepers, Rutger H.; Raghoebar, Gerry M.; Vissink, Arjan; Stenekes, Martin W.; Kraeima, Joep; Roodenburg, Jan L.; Reintsema, Harry; Witjes, Max J.

    Background: The purpose of this study was to analyze the accuracy of mandibular reconstruction using patient-specific computer-aided designed and computer-aided manufactured (CAD/CAM) reconstruction plates as a guide to place fibula grafts and dental implants in a one-stage procedure using

  11. Validation of ocean color sensors using a profiling hyperspectral radiometer

    Science.gov (United States)

    Ondrusek, M. E.; Stengel, E.; Rella, M. A.; Goode, W.; Ladner, S.; Feinholz, M.

    2014-05-01

    Validation measurements of satellite ocean color sensors require in situ measurements that are accurate, repeatable and traceable enough to distinguish variability between in situ measurements and variability in the signal being observed on orbit. The utility of using a Satlantic Profiler II equipped with HyperOCR radiometers (Hyperpro) for validating ocean color sensors is tested by assessing the stability of the calibration coefficients and by comparing Hyperpro in situ measurements to other instruments and between different Hyperpros in a variety of water types. Calibration and characterization of the NOAA Satlantic Hyperpro instrument is described and concurrent measurements of water-leaving radiances conducted during cruises are presented between this profiling instrument and other profiling, above-water and moored instruments. The moored optical instruments are the US operated Marine Optical BuoY (MOBY) and the French operated Boussole Buoy. In addition, Satlantic processing versions are described in terms of accuracy and consistency. A new multi-cast approach is compared to the most commonly used single cast method. Analysis comparisons are conducted in turbid and blue water conditions. Examples of validation matchups with VIIRS ocean color data are presented. With careful data collection and analysis, the Satlantic Hyperpro profiling radiometer has proven to be a reliable and consistent tool for satellite ocean color validation.

  12. Development of a Climatology of Vertically Complete Wind Profiles from Doppler Radar Wind Profiler Systems

    Science.gov (United States)

    Barbre, Robert E., Jr.

    2015-01-01

    commands, provided the program applies the procedures that this report describes to new DRWP data on DOL. Decker et al. (2015) details how SLS is proposing to use DRWP data and splicing techniques on DOL. Although automation could enhance the current DOL 50-MHz DRWP QC process and could streamline any future DOL 915-MHz DRWP QC and splicing process, the DOL community would still require manual intervention to ensure that the vehicle only uses valid profiles. If a program desires to use high spatial resolution profiles, then the algorithm could randomly add high-frequency components to the DRWP profiles. The spliced DRWP database provides lots of flexibility in how one performs DOL simulations, and the algorithms that this report provides will assist the aerospace and atmospheric communities that are interested in utilizing the DRWP.

  13. Error Estimation and Accuracy Improvements in Nodal Transport Methods; Estimacion de Errores y Aumento de la Precision en Metodos Nodales de Transporte

    Energy Technology Data Exchange (ETDEWEB)

    Zamonsky, O M [Comision Nacional de Energia Atomica, Centro Atomico Bariloche (Argentina)

    2000-07-01

    The accuracy of the solutions produced by the Discrete Ordinates neutron transport nodal methods is analyzed.The obtained new numerical methodologies increase the accuracy of the analyzed scheems and give a POSTERIORI error estimators. The accuracy improvement is obtained with new equations that make the numerical procedure free of truncation errors and proposing spatial reconstructions of the angular fluxes that are more accurate than those used until present. An a POSTERIORI error estimator is rigurously obtained for one dimensional systems that, in certain type of problems, allows to quantify the accuracy of the solutions. From comparisons with the one dimensional results, an a POSTERIORI error estimator is also obtained for multidimensional systems. LOCAL indicators, which quantify the spatial distribution of the errors, are obtained by the decomposition of the menctioned estimators. This makes the proposed methodology suitable to perform adaptive calculations. Some numerical examples are presented to validate the theoretical developements and to illustrate the ranges where the proposed approximations are valid.

  14. Use of an Innovative Personality-Mindset Profiling Tool to Guide Culture-Change Strategies among Different Healthcare Worker Groups.

    Directory of Open Access Journals (Sweden)

    M Lindsay Grayson

    Full Text Available Important culture-change initiatives (e.g. improving hand hygiene compliance are frequently associated with variable uptake among different healthcare worker (HCW categories. Inherent personality differences between these groups may explain change uptake and help improve future intervention design.We used an innovative personality-profiling tool (ColourGrid® to assess personality differences among standard HCW categories at five large Australian hospitals using two data sources (HCW participant surveys [PS] and generic institution-wide human resource [HR] data to: a compare the relative accuracy of these two sources; b identify differences between HCW groups and c use the observed profiles to guide design strategies to improve uptake of three clinically-important initiatives (improved hand hygiene, antimicrobial stewardship and isolation procedure adherence.Results from 34,243 HCWs (HR data and 1045 survey participants (PS data suggest that HCWs were different from the general population, displaying more individualism, lower power distance, less uncertainty avoidance and greater cynicism about advertising messages. HR and PS data were highly concordant in identifying differences between the three key HCW categories (doctors, nursing/allied-health, support services and predicting appropriate implementation strategies. Among doctors, the data suggest that key messaging should differ between full-time vs part-time (visiting senior medical officers (SMO, VMO and junior hospital medical officers (HMO, with SMO messaging focused on evidence-based compliance, VMO initiatives emphasising structured mandatory controls and prestige loss for non-adherence, and for HMOs focusing on leadership opportunity and future career risk for non-adherence.Compared to current standardised approaches, targeted interventions based on personality differences between HCW categories should result in improved infection control-related culture-change uptake. Personality

  15. Use of an Innovative Personality-Mindset Profiling Tool to Guide Culture-Change Strategies among Different Healthcare Worker Groups.

    Science.gov (United States)

    Grayson, M Lindsay; Macesic, Nenad; Huang, G Khai; Bond, Katherine; Fletcher, Jason; Gilbert, Gwendolyn L; Gordon, David L; Hellsten, Jane F; Iredell, Jonathan; Keighley, Caitlin; Stuart, Rhonda L; Xuereb, Charles S; Cruickshank, Marilyn

    2015-01-01

    Important culture-change initiatives (e.g. improving hand hygiene compliance) are frequently associated with variable uptake among different healthcare worker (HCW) categories. Inherent personality differences between these groups may explain change uptake and help improve future intervention design. We used an innovative personality-profiling tool (ColourGrid®) to assess personality differences among standard HCW categories at five large Australian hospitals using two data sources (HCW participant surveys [PS] and generic institution-wide human resource [HR] data) to: a) compare the relative accuracy of these two sources; b) identify differences between HCW groups and c) use the observed profiles to guide design strategies to improve uptake of three clinically-important initiatives (improved hand hygiene, antimicrobial stewardship and isolation procedure adherence). Results from 34,243 HCWs (HR data) and 1045 survey participants (PS data) suggest that HCWs were different from the general population, displaying more individualism, lower power distance, less uncertainty avoidance and greater cynicism about advertising messages. HR and PS data were highly concordant in identifying differences between the three key HCW categories (doctors, nursing/allied-health, support services) and predicting appropriate implementation strategies. Among doctors, the data suggest that key messaging should differ between full-time vs part-time (visiting) senior medical officers (SMO, VMO) and junior hospital medical officers (HMO), with SMO messaging focused on evidence-based compliance, VMO initiatives emphasising structured mandatory controls and prestige loss for non-adherence, and for HMOs focusing on leadership opportunity and future career risk for non-adherence. Compared to current standardised approaches, targeted interventions based on personality differences between HCW categories should result in improved infection control-related culture-change uptake. Personality

  16. Performance of the first European 482 MHz wind profiler radar with RASS under operational conditions

    Energy Technology Data Exchange (ETDEWEB)

    Steinhagen, H.; Engelbart, D.; Goersdorf, U.; Lehmann, V.; Neisser, J. [Deutscher Wetterdienst, Lindenberg (Germany). Meteorologisches Observatorium; Dibbern, J.; Neuschaefer, J.W.

    1998-10-01

    The first 482 MHz wind profiler radar (WPR) in Europe completed with a radio-acoustic sounding system (RASS) has been operated at the meteorological observatory Lindenberg since July 3rd, 1996 after a comprehensive study regarding the investigation of frequency compatibility between the WPR and the television channel 22 (478-486 MHz). The WPR can operate with different height and time resolutions (e.g. 250 m in the so-called low mode or 500 m in the high mode). A height range of up to approximately 16 km can be realized in the high mode. The installed WPR/RASS combination allows also the measurement of profiles of the virtual temperature with the low mode resolution in the height range from 500 m up to approximately 4000 m. The main objective of this contribution is the investigation of the accuracy and the availability of this new remote sensing system. First results of the accuracy can be given on the base of about 1000 intercomparisons between WPR/RASS and rawinsonde data. The bias of the horizontal wind velocities is less than 0.4 m/s in the low mode and 0.7 m/s in the high mode (from 3 to 10 km) and therefore smaller than the average accuracy of both systems. The bias of the temperature measurements is less than 1 K and can be improved by some corrections in future. A first statistics of the data availability can be shown based on nearly 6000 profiles of wind and temperature. The 80% availability of the WPR/RASS was determined with 12.8 km for wind and 2.3 km for temperature measurements. The new possibilities of investigating the troposphere as well as the lowest part of the stratosphere are presented by measurement examples from February and March 1997. (orig.) 22 refs.

  17. Objective measurement of inhaler inhalation flow profile using acoustic methods

    Energy Technology Data Exchange (ETDEWEB)

    Lacalle, H.; Taylor, T.E.; Marco, S.; Reilly, R.B.

    2016-07-01

    Patients with asthma and chronic obstructive pulmonary diseases (COPD) are mostly treated with inhalers that deliver medication directly to their airways. Drug delivery from dry powder inhalers (DPIs) is very much reliant on the inhalation manoeuvre, specifically the peak inspiratory flow rate (PIFR), inspiratory capacity (IC) and inhalation rise time (IRT) of the inhalation. It has been widely reported that patients may not follow correct inhalation technique while using their inhaler. In this study, a novel acoustic method is proposed to accurately estimate inhalation flow profile using only one inhalation recording for calibration. An Ellipta DPI was placed inside an airtight container with a spirometer connected in order to measure inhalation flow parameters. An acoustic recording device (Inhaler Compliance Assessment (INCA)) was also attached to the DPI. Inhalation audio and flow signals were recorded simultaneously. The data were collected from 20 healthy subjects while performing inhaler inhalations at a range of inspiratory flow rates. A power law regression model was computed to obtain the relationship between the acoustic envelope of the inhalation and flow profile of each recording. Each model was tested on the remaining audio signals to estimate flow profile. The average estimation error was found to be 10.5±0.3% for estimating flow profile from audio signals. Inhalation flow profile parameters (PIFR, IC and IRT) could then be measured from the estimated flow profile with high accuracy giving information on user inhalation technique. This method may assist in improving patient inhaler adherence and overall disease control. (Author)

  18. Accuracy of only children stereotype

    OpenAIRE

    Mõttus, Rene; Indus, Kristjan; Allik, Jueri

    2008-01-01

    Both expert and folk psychologists believe that only children are spoiled, selfish, lonely, and socially estranged. In this study, we demonstrate that the stereotypical personality profile of a typical only child differs consistently from the stereotypical profile of those who have siblings on 23 out of the 30 NEO-PI-R subscales. These differences between stereotypical personality profiles do not reflect self-descriptions because the self-rated personality profiles made by only children coinc...

  19. Test expectancy affects metacomprehension accuracy.

    Science.gov (United States)

    Thiede, Keith W; Wiley, Jennifer; Griffin, Thomas D

    2011-06-01

    Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and practice tests. The purpose of the present study was to examine whether the accuracy metacognitive monitoring was affected by the nature of the test expected. Students (N= 59) were randomly assigned to one of two test expectancy groups (memory vs. inference). Then after reading texts, judging learning, completed both memory and inference tests. Test performance and monitoring accuracy were superior when students received the kind of test they had been led to expect rather than the unexpected test. Tests influence students' perceptions of what constitutes learning. Our findings suggest that this could affect how students prepare for tests and how they monitoring their own learning. ©2010 The British Psychological Society.

  20. Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol

    Directory of Open Access Journals (Sweden)

    Corina Marilena Cristache

    2017-01-01

    Full Text Available The aim of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. Materials and Methods. Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann–Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. Results. Mean (and standard deviation of 3D error at the entry point was 0.798 mm (±0.52, at the implant apex it was 1.17 mm (±0.63, and mean angular deviation was 2.34 (±0.85. A statistically significant reduced 3D error was observed at entry point p=.037, at implant apex p=.008, and also in angular deviation p=.030 in mandible when comparing to maxilla. Conclusions. The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning.