  1. Accreditation of laboratories in the field of radiation protection

    International Nuclear Information System (INIS)

    Galjanic, S.; Franic, Z.

    2005-01-01

    This paper gives a review of requirements and procedures for the accreditation of test and calibration laboratories in the field of radiation protection, paying particular attention to Croatia. General requirements to be met by a testing or calibration laboratory to be accredited are described in the standard HRN EN ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories. The quality of a radiation protection programme can only be as good as the quality of the measurements made to support it. Measurement quality can be assured by participation in measurement assurance programmes that evaluate the appropriateness of procedures, facilities, and equipment and include periodic checks to assure adequate performance. These also include internal consistency checks, proficiency tests, intercomparisons and site visits by technical experts to review operations. In Croatia, laboratories are yet to be accredited in the field of radiation protection. However, harmonisation of technical legislation with the EU legal system will require some changes in laws and regulations in the field of radiation protection, including the ones dealing with the notification of testing laboratories and connected procedures. Regarding the notification procedures for testing laboratories in Croatia, in the regulated area, the existing accreditation infrastructure, i.e. Croatian Accreditation Agency is ready for its implementation, as it has already established and further developed a consistent accreditation system, compatible with international requirements and procedures.(author)

  2. Accredited dose measurements for validation of radiation sterilized products

    DEFF Research Database (Denmark)

    Miller, A.

    1993-01-01

    for control of radiation sterilization. The accredited services include: 1. 1. Irradiation of dosimeters and test samples with cobalt-60 gamma rays. 2. 2. Irradiation of dosimeters and test samples with 10 MeV electrons. 3. 3. Issue of and measurement with calibrated dosimeters. 4. 4. Measurement...... of the dosimetric parameters of an irradiation facility. 5. 5. Measurement of absorbed dose distribution in irradiated products. The paper describes these services and the procedures necessary for their execution....

  3. Experiences in Accreditation of Laboratories in the Field of Radiation Science

    International Nuclear Information System (INIS)

    Franic, Z.; Galjanic, S.; Krizanec, D.

    2011-01-01

    Efficient interaction of technical legislation, metrology, standardization and accreditation within the system of quality infrastructure is precondition for assurance of safety of goods and services as well as protection of humans and environment. In the paper importance of quality infrastructure on national and international levels is presented while special interest is paid to accreditation. Current situation regarding the accreditation of laboratories in the field of radiation science is presented. Regarding this field, in Croatia three laboratories are accredited by Croatian Accreditation Agency: 1. Laboratory for Radioecology, Rudjer Boskovic Institute (Scope: Measurement of radionuclide content in environmental samples and commodities - Including foodstuffs and drinking water) 2. EKOTEH Dozimetrija Ltd., Department for Radiation Protection (Scope: Testing in the scope of ionizing and nonionizing radiation) 3. Radiation Protection Unit, Institute for Medical Research and Occupational Health (Scope: Determination of radioactivity). (author)

  4. Towards ABET accreditation for a SWE program: alternative student assessment techniques

    International Nuclear Information System (INIS)

    Alghamdi, A.; Nasir, M.; Alnafjan, K.

    2011-01-01

    This paper describes assessment techniques utilized for assessing undergraduate students studying in a software engineering program. The purpose behind this work is to get the program accredited by the Accreditation Board of Engineering and Technology (ABET). Therefore, a number of applied direct and indirect assessment techniques are described. These techniques are implemented towards the end of the semester to assess the extent to which the student and course outcomes are satisfied. Consequently, results are obtained and analyzed and various learning issues are eventually identified. Finally, the paper provides suggestions for improvement in course delivery as well as learning mechanism. (author)

  5. Radiation scattering techniques

    International Nuclear Information System (INIS)

    Edmonds, E.A.

    1986-01-01

    Radiation backscattering techniques are useful when access to an item to be inspected is restricted to one side. These techniques are very sensitive to geometrical effects. Scattering processes and their application to the determination of voids, thickness measuring, well-logging and the use of x-ray fluorescence techniques are discussed. (U.K.)

  6. Personnel radiation dosimetry laboratory accreditation programme for thermoluminescent dosimeters : a proposal

    International Nuclear Information System (INIS)

    Bhatt, B.C.; Srivastava, J.K.; Iyer, P.S.; Venkatraman, G.

    1993-01-01

    Accreditation for thermoluminescent dosimeters is the process of evaluating a programme intending to use TL personnel dosimeters to measure, report and record dose equivalents received by radiation workers. In order to test the technical competence for conducting personnel dosimetry service as well as to decentralize personnel monitoring service, it has been proposed by Radiological Physics Division (RPhD) to accredit some of the laboratories, in the country. The objectives of this accreditation programme are: (i) to give recognition to competent dosimetry processors, and (ii) to provide periodic evaluation of dosimetry processors, including review of internal quality assurance programme to improve the quality of personnel dosimetry processing. The scientific support for the accreditation programme will be provided by the scientific staff from Radiological Physics Division (RPhD) and Radiation Protection Services Division (RPSD). This paper describes operational and technical requirements for the Personnel Radiation Dosimetry Laboratory Accreditation Programme for Thermoluminescent Dosimeters for Personnel Dosimetry Processors. Besides, many technical documents dealing with the TL Personnel Dosimeter System have been prepared. (author). 5 refs., 2 figs

  7. Techniques of radiation dosimetry

    International Nuclear Information System (INIS)

    Mahesk, K.

    1985-01-01

    A text and reference with an interdisciplinary approach to physics, atomic energy, radiochemistry, and radiobiology. Chapters examine basic principles, experimental techniques, the methodology of dose experiments, and applications. Treats 14 different dosimetric techniques, including ionization chamber, thermoluminescence, and lyoluminescence. Considers the conceptual aspects and characteristic features of radiation

  8. Radiation techniques for acromegaly

    Directory of Open Access Journals (Sweden)

    Minniti Giuseppe

    2011-12-01

    Full Text Available Abstract Radiotherapy (RT remains an effective treatment in patients with acromegaly refractory to medical and/or surgical interventions, with durable tumor control and biochemical remission; however, there are still concerns about delayed biochemical effect and potential late toxicity of radiation treatment, especially high rates of hypopituitarism. Stereotactic radiotherapy has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. Radiation can be delivered in a single fraction by stereotactic radiosurgery (SRS or as fractionated stereotactic radiotherapy (FSRT in which smaller doses are delivered over 5-6 weeks in 25-30 treatments. A review of the recent literature suggests that pituitary irradiation is an effective treatment for acromegaly. Stereotactic techniques for GH-secreting pituitary tumors are discussed with the aim to define the efficacy and potential adverse effects of each of these techniques.

  9. Radiation techniques for acromegaly

    International Nuclear Information System (INIS)

    Minniti, Giuseppe; Scaringi, Claudia; Enrici, Riccardo Maurizi

    2011-01-01

    Radiotherapy (RT) remains an effective treatment in patients with acromegaly refractory to medical and/or surgical interventions, with durable tumor control and biochemical remission; however, there are still concerns about delayed biochemical effect and potential late toxicity of radiation treatment, especially high rates of hypopituitarism. Stereotactic radiotherapy has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. Radiation can be delivered in a single fraction by stereotactic radiosurgery (SRS) or as fractionated stereotactic radiotherapy (FSRT) in which smaller doses are delivered over 5-6 weeks in 25-30 treatments. A review of the recent literature suggests that pituitary irradiation is an effective treatment for acromegaly. Stereotactic techniques for GH-secreting pituitary tumors are discussed with the aim to define the efficacy and potential adverse effects of each of these techniques

  10. Accreditation and Radiation Protection - Do We Need It Because of the Law or Because of Us

    International Nuclear Information System (INIS)

    Omahen, G.; Zdesar, U.

    2011-01-01

    Laboratories involved in the protection against radiation and therefore in the measurement of radioactivity, dose rate and contamination have always been tied to the quality of their measurements, particularly those that have performed measurements for nuclear power plants. However in the laboratories more than quality it was more important, that people are professional, that they are engaged in scientific work and know how to interpret the results. Very often these are things that do not go along with reviewing the measuring instruments and quality records. However customer requires measurement results that can be trusted. This is the purpose of the standard SIST EN ISO / IEC 17025 in which the requirements for testing and calibration laboratories are standardised. The standard is in force since 1999. In some countries, a request for accreditation of testing laboratories according to SIST EN ISO / IEC 17025 is even in regulation. This request is for example in the Croatian and Slovenian regulations for laboratories involved in measuring the radioactivity, dose rate, contamination, or by checking the X-ray apparatus. Several laboratories have been accredited for several years. From that experience we can conclude that customer gets reliable results from the accredited laboratories at relatively low cost. On the other side laboratory which is accredited has introduced a line of work in the laboratory, there are rules for equipment, personnel, training and all that eventually enhance measurement expertise. With accreditation, it is much easier to compensate for the loss of workers due to pension or leaving the laboratory because every moment must always be in the laboratory at least two who know how to work on the method. Accreditation is not improving radiation protection or reducing becquerel in the air. But at least we know how accurate mSv or Bq are and how small mSv and Bq can be measured. (author)

  11. Accreditation and radiation protection - the cost or smaller doses and reliable results

    International Nuclear Information System (INIS)

    Omahen, G.; Zdesar, U.

    2011-01-01

    Laboratories involved in the protection against radiation and therefore in the measurement of radioactivity, dose rate and contamination have always been tied to the quality of their measurements, particularly those that have performed measurements for nuclear power plants. However in the laboratories more than quality it was more important, that people are professional, that they are engaged in scientific work and know how to interpret the results. Very often these are things that do not go along with reviewing the measuring instruments and quality records. However customer requires measurement results that can be trusted. This is the purpose of the standard SIST EN ISO / IEC 17025 in which the requirements for testing and calibration laboratories are standardised. The standard in force since 1999. In some countries, requests for accreditation of testing laboratories according to SIST EN ISO / IEC 17025 is even in regulation. This request is for example in the Croatian and Slovenian regulations for laboratories involved in measuring the radioactivity, dose rate, contamination, or by checking the X-ray apparatus. Several laboratories have been accreditation for several years. From that experience we can conclude that customer gets reliable results from the accredited laboratories at relatively low cost. On the other side laboratory which his accredited has introduced a line of work and his laboratory, there are rules for equipment, personnel, training and all that eventually enhanced measurement expertise. With accreditation, it is much easier to compensate for the loss of workers due to pension or leaving the laboratory because every moment must always be in the laboratory at least two who know how to work on the method. Accreditation is not improving radiation protection or reducing Becquerel in the air. But at least we know how accurate mSv or Bq are and how small mSv and Bq can be measured. (author) [sr

  12. The technique on handling radiation

    International Nuclear Information System (INIS)

    1997-11-01

    This book describes measurement of radiation and handling radiation. The first part deals with measurement of radiation. The contents of this part are characteristic on measurement technique of radiation, radiation detector, measurement of energy spectrum, measurement of radioactivity, measurement for a level of radiation and county's statistics on radiation. The second parts explains handling radiation with treating of sealed radioisotope, treating unsealed source and radiation shield.

  13. Secondary calibration laboratory for ionizing radiation laboratory accreitation program National Institute of Standards and Technology National Voluntary Laboratory Accreditation Program

    Energy Technology Data Exchange (ETDEWEB)

    Martin, P.R.

    1993-12-31

    This paper presents an overview of the procedures and requirements for accreditation under the Secondary Calibration Laboratory for Ionizing Radiation Program (SCLIR LAP). The requirements for a quality system, proficiency testing and the onsite assessment are discussed. The purpose of the accreditation program is to establish a network of secondary calibration laboratories that can provide calibrations traceable to the primary national standards.

  14. Secondary calibration laboratory for ionizing radiation laboratory accreitation program National Institute of Standards and Technology National Voluntary Laboratory Accreditation Program

    International Nuclear Information System (INIS)

    Martin, P.R.

    1993-01-01

    This paper presents an overview of the procedures and requirements for accreditation under the Secondary Calibration Laboratory for Ionizing Radiation Program (SCLIR LAP). The requirements for a quality system, proficiency testing and the onsite assessment are discussed. The purpose of the accreditation program is to establish a network of secondary calibration laboratories that can provide calibrations traceable to the primary national standards

  15. Accredited training on radiation protection for the Austrian police

    International Nuclear Information System (INIS)

    Timal, G.

    2009-01-01

    In Austria, radiological emergencies are handled following the Intervention Regulation, in force since 2007. This regulation also defines duration and content for the training of radiation protection personnel, taking advantage of the standard OeNORM S 5207 published in 2005. Radiation protection personnel of the Austrian police are trained at the Federal Security Academy in Traiskirchen near Vienna. The Federal Security Academy is a training centre certified by the Austrian Standards Institute. The poster describes the modular organisation of the training and its duration and content as well as the further trainings available to the radiation protection personnel of the Police. (orig.)

  16. Food physics and radiation techniques

    International Nuclear Information System (INIS)

    Szabo, A. S.

    1999-01-01

    In the lecture information is given about food physics, which is a rather new, interdisciplinary field of science, connecting food science and applied physics. The topics of radioactivity of foodstuffs and radiation techniques in the food industry are important parts of food physics detailed information will be given about the main fields (e.g. radio stimulation, food preservation) of radiation techniques in the agro-food sector. Finally some special questions of radioactive contamination of foodstuffs in hungary and applicability of radioanalytical techniques (e.g. Inaa) for food investigation will be analyzed and discussed

  17. Experimental comparison among the laboratories accredited within the framework of the European Co-operation for Accreditation on the calibration of a radiation protection dosimeters in the terms of the quantity air Kerma

    International Nuclear Information System (INIS)

    Bovi, M.; Toni, M.P.; Tricomi, G.

    2002-01-01

    The European co-operation for Accreditation (EA) formalises the collaboration of the Accreditation Bodies of the Member States of the European Union and the European Free Trade Association covering all conformity assessment activities. This collaboration is based on a Memorandum of Understanding dated the 27 November 1997 and aims at developing and maintain Multilateral Agreements (MLAs) within EA and with non-members accreditation bodies. MLAs Signatories guarantee uniformity of accreditation by continuous and rigorous evaluation. Based on mutual confidence, the MLAs recognise the equivalence of the accreditation systems administered by EA Members and of certificates and reports issued by bodies accredited under these systems. A basic element of the program to establish and maintain mutual confidence among calibration services is the participation of the accredited laboratories in experimental interlaboratory comparisons (ILC) organised by EA members or other international organisations. The aim of these ILC is to verify the technical equivalence of calibration services within the EA. The ILC which it is dealt with in the present work was recently carried out over a period of two years, ending in May 2002. It interested the laboratories accredited in the ionising radiation field for calibration of dosimeters at radiation protection levels in terms of the quantity air kerma (K air ) due to 6 0C o and 1 37C s gamma radiation. The ILC was planned by the EA expert group on Ionising radiation and radioactivity and approved by the EA General Assembly in December 1999 with the title Calibration of a Radiation Protection Dosimeter under the code IR3. The need of this comparison also resulted from an inquiry carried out in 1998 by the expert group among the different Accreditation Bodies members of EA and associated to EA. The organization of the ILC was carried out according to the EA rules by the Italian Accreditation Body in the ionising radiation field, the SIT

  18. Comparison of Onsite Versus Online Chart Reviews as Part of the American College of Radiation Oncology Accreditation Program.

    Science.gov (United States)

    Hepel, Jaroslaw T; Heron, Dwight E; Mundt, Arno J; Yashar, Catheryn; Feigenberg, Steven; Koltis, Gordon; Regine, William F; Prasad, Dheerendra; Patel, Shilpen; Sharma, Navesh; Hebert, Mary; Wallis, Norman; Kuettel, Michael

    2017-05-01

    Accreditation based on peer review of professional standards of care is essential in ensuring quality and safety in administration of radiation therapy. Traditionally, medical chart reviews have been performed by a physical onsite visit. The American College of Radiation Oncology Accreditation Program has remodeled its process whereby electronic charts are reviewed remotely. Twenty-eight radiation oncology practices undergoing accreditation had three charts per practice undergo both onsite and online review. Onsite review was performed by a single reviewer for each practice. Online review consisted of one or more disease site-specific reviewers for each practice. Onsite and online reviews were blinded and scored on a 100-point scale on the basis of 20 categories. A score of less than 75 was failing, and a score of 75 to 79 was marginal. Any failed charts underwent rereview by a disease site team leader. Eighty-four charts underwent both onsite and online review. The mean scores were 86.0 and 86.9 points for charts reviewed onsite and online, respectively. Comparison of onsite and online reviews revealed no statistical difference in chart scores ( P = .43). Of charts reviewed, 21% had a marginal (n = 8) or failing (n = 10) score. There was no difference in failing charts ( P = .48) or combined marginal and failing charts ( P = .13) comparing onsite and online reviews. The American College of Radiation Oncology accreditation process of online chart review results in comparable review scores and rate of failing scores compared with traditional on-site review. However, the modern online process holds less potential for bias by using multiple reviewers per practice and allows for greater oversight via disease site team leader rereview.

  19. (Re)implantation of quality system of LCR (Laboratory for Radiation Sciences) for accreditation in the standard ABNT NBR ISO/IEC 17025:2005

    International Nuclear Information System (INIS)

    Leite, Sandro P.; Fernandes, Elisabeth O.; David, Mariano G.; Pires, Evandro J.; Alves, Carlos F.E.; Almeida, Carlos E.

    2014-01-01

    This paper presents preparing procedure of the metrology laboratory (LABMETRO), which belongs Laboratorio de Ciencias Radiologicas of Rio de Janeiro , for postulating accreditation of its services metrology to INMETRO. This process, supported by the Technological Services Network SIBRATEC/FINEP for Radiation Protection and Dosimetry Technological Services, had as one of its aims to avoid possible technical barriers to the purchase services in the area of ionizing radiation laboratories. Accreditation will also enable the integration of services such laboratories in Brazilian Calibration Network (RBC). (author)

  20. Electron beam instrumentation techniques using coherent radiation

    International Nuclear Information System (INIS)

    Wang, D.X.

    1997-01-01

    Much progress has been made on coherent radiation research since coherent synchrotron radiation was first observed in 1989. The use of coherent radiation as a bunch length diagnostic tool has been studied by several groups. In this paper, brief introductions to coherent radiation and far-infrared measurement are given, the progress and status of their beam diagnostic application are reviewed, different techniques are described, and their advantages and limitations are discussed

  1. Evaluating the Accreditation Council on Graduate Medical Education core clinical competencies: techniques and feasibility in a urology training program.

    Science.gov (United States)

    Miller, David C; Montie, James E; Faerber, Gary J

    2003-10-01

    We describe several traditional and novel techniques for teaching and evaluating the Accreditation Council on Graduate Medical Education (ACGME) core clinical competencies in a urology residency training program. The evolution and underpinnings of the ACGME Outcome Project were reviewed. Several publications related to the evaluation of clinical competencies as well as current assessment techniques at our institution were also analyzed. Several tools for the assessment of clinical competencies have been developed and refined in response to the ACGME Outcome project. Standardized patient encounters and expanded patient satisfaction surveys may prove useful with regard to assessing resident professionalism, patient care and communication skills. A feasible and possibly undervalued technique for evaluating a number of core competencies is the implementation of formal written appraisals of the nature and quality of resident performance at departmental conferences. The assessment of competency in practice based learning and systems based practice may be achieved through innovative exercises, such as practice guideline development, that assess the evidence for various urologic interventions as well as the financial and administrative aspects of such care. We describe several contemporary methods for teaching and evaluating the core clinical competencies in a urology training program. While the techniques described are neither comprehensive nor feasible for every program, they nevertheless provide an important starting point for a meaningful exchange of ideas in the urological graduate medical education community.

  2. Establishment of qualities mammography according to the standard IEC-61267 in the laboratory of metrology of ionizing radiation of the National Center of Dosimetry and enlargement of the accreditation by ENAC

    International Nuclear Information System (INIS)

    Roig Petit, F.; Mestre de Juan, V.; Alabau Albors, J.; Palma Copete, J.; Ruiz Rodriguez, J. C.; Pons Mocholi, S.

    2013-01-01

    The extension of the accreditation of the laboratory of the National Center Dosimetry (No. 58/LC10.036) by the national accreditation entity (ENAC), according to the ISO 17025 standard [2], for the standard qualities of mammography by the IEC 61267 comes to meet part of the needs that demand our health care environment in terms of radiation measuring instruments calibration. This work intends to publicize this enlargement commenting on the different phases of the process to get the accreditation. (Author)

  3. Techniques for controlling radiation exposure

    International Nuclear Information System (INIS)

    Ocken, H.; Wood, C.J.

    1993-01-01

    The US nuclear power industry has been remarkably successful in reducing worker radiation exposure over the past 10 years. There has been more than a fourfold reduction in person-rem per MW-year of electric power generated: from 1.8 person-rems in 1980 to only 0.4 person-rems in 1991. Despite this substantial improvement, challenges for the industry remain. Individual exposure limits have been tightened in the 1990 Recommendations of the International Commission on Radiological Protection, ICRP Publication 60, and there will be more requirements for special maintenance work as plants age, suggesting that vigorous efforts will be required to meet the 1995 industry goals for unit median collective exposure. No one method will suffice, but implementing suitable combinations from this compendium will help utilities to achieve their exposure goals. Radiation reduction is generally cost-effective: Outages are shorter, staffing requirements are reduced, and work quality is improved. Despite up-front costs, the benefits over the following one to three years typically outweigh the expenses

  4. Monte Carlo techniques in radiation therapy

    CERN Document Server

    Verhaegen, Frank

    2013-01-01

    Modern cancer treatment relies on Monte Carlo simulations to help radiotherapists and clinical physicists better understand and compute radiation dose from imaging devices as well as exploit four-dimensional imaging data. With Monte Carlo-based treatment planning tools now available from commercial vendors, a complete transition to Monte Carlo-based dose calculation methods in radiotherapy could likely take place in the next decade. Monte Carlo Techniques in Radiation Therapy explores the use of Monte Carlo methods for modeling various features of internal and external radiation sources, including light ion beams. The book-the first of its kind-addresses applications of the Monte Carlo particle transport simulation technique in radiation therapy, mainly focusing on external beam radiotherapy and brachytherapy. It presents the mathematical and technical aspects of the methods in particle transport simulations. The book also discusses the modeling of medical linacs and other irradiation devices; issues specific...

  5. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    Relations between radiation risks and radiation protection measuring techniques are considered as components of the radiation risk. The influence of the exposure risk on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Based upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high exposure risk. As a consequence the following recommendations are presented: occupationally exposed persons with small exposure risk should be monitored using only a long-term desimeter (for instance a thermoluminescence desimeter). In the case of internal exposure, the surface and air contamination levels should be controlled so strictly that routine measurements of internal contamination need not be performed

  6. Analytical research using synchrotron radiation based techniques

    International Nuclear Information System (INIS)

    Jha, Shambhu Nath

    2015-01-01

    There are many Synchrotron Radiation (SR) based techniques such as X-ray Absorption Spectroscopy (XAS), X-ray Fluorescence Analysis (XRF), SR-Fourier-transform Infrared (SRFTIR), Hard X-ray Photoelectron Spectroscopy (HAXPS) etc. which are increasingly being employed worldwide in analytical research. With advent of modern synchrotron sources these analytical techniques have been further revitalized and paved ways for new techniques such as microprobe XRF and XAS, FTIR microscopy, Hard X-ray Photoelectron Spectroscopy (HAXPS) etc. The talk will cover mainly two techniques illustrating its capability in analytical research namely XRF and XAS. XRF spectroscopy: XRF spectroscopy is an analytical technique which involves the detection of emitted characteristic X-rays following excitation of the elements within the sample. While electron, particle (protons or alpha particles), or X-ray beams can be employed as the exciting source for this analysis, the use of X-ray beams from a synchrotron source has been instrumental in the advancement of the technique in the area of microprobe XRF imaging and trace level compositional characterisation of any sample. Synchrotron radiation induced X-ray emission spectroscopy, has become competitive with the earlier microprobe and nanoprobe techniques following the advancements in manipulating and detecting these X-rays. There are two important features that contribute to the superb elemental sensitivities of microprobe SR induced XRF: (i) the absence of the continuum (Bremsstrahlung) background radiation that is a feature of spectra obtained from charged particle beams, and (ii) the increased X-ray flux on the sample associated with the use of tunable third generation synchrotron facilities. Detection sensitivities have been reported in the ppb range, with values of 10 -17 g - 10 -14 g (depending on the particular element and matrix). Keeping in mind its demand, a microprobe XRF beamline has been setup by RRCAT at Indus-2 synchrotron

  7. Accredition: An accredited utility's perspective

    International Nuclear Information System (INIS)

    Jambrovic, H.

    1990-01-01

    Accredition is a quality assurance program that applies to electricity billing meters. Under the Electricity and Gas Inspection Act, an electricity meter is not a legal billing device until a prototype has been scrutinized and approved for use by Consumer and Corporate Affairs Canada (CCAC) laboratories, and a meter cannot be used for billing purposes unless its accuracy and condition have been inspected and the meter is sealed to prevent tampering. In 1986 an ammendment to the act allowed accredited organizations to inspect, verify and seal their own billing meters. Ontario Hydro embarked on a program to become accredited in 1987, to offset spiraling government inspection fees in the order of $500,000/y, and to be less dependent on the availability of government inspectors. Ontario Hydro achieved accredition status two years after embarking on the program, which involved completion of cost benefit analysis, securing senior management commitment, preparation of a comprehensive quality assurance program manual, implementation of quality assurance program policies, procedures and controls, submitting meter shop operations and field meter handling practices to both internal Ontario Hydro and external government audit, and correction of audit findings. 2 figs

  8. Role of radiation dating technique - one example

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Shigueo [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Etchevarne, Carlos A. [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Fac. de Filosofia e Ciencias Humanas. Dept. Antropologia e Etnologia; Cano, Nilo F.; Munita, C.S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-07-01

    Full text: The great majority of archaeological or geological dating technique is based on radiation effect. The so called radioactivity method uses radioactive decays of elements. This is the case of the well known radiocarbon or carbon-14 method. Also the method of relating daughter nucleus to decaying nucleus, as in K-40/Ar-40, Th- 230/U-234, etc. Here we will concentrate in the method based on energy deposition in a solid by radiation from the disintegration of U-series and Th-series. {beta}-rays emitted by the decay of K-40 into Ca-40 (80%) and Ar-40 (11%) also contributes. The role of {alpha}, {beta} and {gamma} radiation emitted by radionuclides in the U-238 and Th-232 series and of {beta} rays from the decay of K-40, all of them in the soil irradiate anything in their course. For dating, we can have sediments as well as potteries produced by ancient people and became buried. The important process consists in transferring a fraction of the energy of radiation to the solid, mainly liberating electrons from valence band to conduction band and from there to traps. In many case the energy of the radiation is used to create defects which in turn create energy levels (traps) in the forbidden gap (or energy gap). There are three ways to recover the energy stored in the solid: (1) by emission of light optically stimulated (OSL), (2) by emission of light thermally stimulated (TL), (3) by microwave absorption (EPR or ESR). Using these techniques among several applications, we will present one to find the first settlers in the northeaster region of Brazil. (author)

  9. Role of radiation dating technique - one example

    International Nuclear Information System (INIS)

    Watanabe, Shigueo

    2012-01-01

    Full text: The great majority of archaeological or geological dating technique is based on radiation effect. The so called radioactivity method uses radioactive decays of elements. This is the case of the well known radiocarbon or carbon-14 method. Also the method of relating daughter nucleus to decaying nucleus, as in K-40/Ar-40, Th- 230/U-234, etc. Here we will concentrate in the method based on energy deposition in a solid by radiation from the disintegration of U-series and Th-series. β-rays emitted by the decay of K-40 into Ca-40 (80%) and Ar-40 (11%) also contributes. The role of α, β and γ radiation emitted by radionuclides in the U-238 and Th-232 series and of β rays from the decay of K-40, all of them in the soil irradiate anything in their course. For dating, we can have sediments as well as potteries produced by ancient people and became buried. The important process consists in transferring a fraction of the energy of radiation to the solid, mainly liberating electrons from valence band to conduction band and from there to traps. In many case the energy of the radiation is used to create defects which in turn create energy levels (traps) in the forbidden gap (or energy gap). There are three ways to recover the energy stored in the solid: (1) by emission of light optically stimulated (OSL), (2) by emission of light thermally stimulated (TL), (3) by microwave absorption (EPR or ESR). Using these techniques among several applications, we will present one to find the first settlers in the northeaster region of Brazil. (author)

  10. Development of radiation preservation technique in Beijing

    International Nuclear Information System (INIS)

    Zhang Hongdi; Li Guixiang; Pang Mei

    1990-12-01

    The 60 Co radiation preservation technique which was used to preserve persimmons, green peppers and four varieties of apple was studied. Apples and persimmons were irradiated with 0.1 ∼ 0.7kGy and 0.1 ∼ 1.0kGy respectively, then they were stored under a constant environmental temperature. Green peppers were treated with heat, irradiated with low dose and stored at low temperature. After a certain time of storing, the results showed that the quality of irradiated groups was better than control group, and there was no difference of main nutrient components between the irradiated groups and the control group. Finally, the radiation processing does not cause radioactivity increasing and microelements decreasing in the food

  11. Patient radiation exposure during different kyphoplasty techniques

    International Nuclear Information System (INIS)

    Panizza, D.; Barbieri, M.; Parisoli, F.; Moro, L.

    2014-01-01

    The scope of this study was to quantify patient radiation exposure during two different techniques of kyphoplasty (KP), which differ by a cement delivery method, in order to assess whether or not one of the two used methods can reduce the patient dose. Twenty patients were examined for this investigation. One X-ray fluoroscopy unit was used for localization, navigation and monitoring of cement delivery. The patient bio-metric data, the setting of the fluoroscope, the exposure time and the kerma-area product (KAP) were monitored in all the procedures for anteroposterior (AP) and lateral (LL) fluoroscopic projections in order to assess the range of radiation doses imparted to the patient. Theoretical entrance skin dose (ESD) and effective dose (E) were calculated from intraoperatively measured KAP. An average ET per procedure was 1.5±0.5 min for the manual injection technique (study A) and 1.4±0.4 min for the distance delivery technique (study B) in the AP plane, while 3.2±0.7 and 5.1±0.6 min in the lateral plane, respectively. ESD was estimated as an average of 0.10±0.06 Gy for study A and 0.13±0.13 Gy for study B in the AP or/and 0.59±0.46 and 1.05±0.36 Gy in the lateral view, respectively. The cumulative mean E was 1.9±1.0 mSv procedure -1 for study A and 3.6±0.9 mSv procedure -1 for study B. Patient radiation exposure and associated effective dose from KP may be considerable. The technique of distance cement delivery appears to be slower than the manual injection technique and it requires a more protracted fluoroscopic control in the lateral projection, so that this system entails a higher amount of dose to the patient. (authors)

  12. Patient radiation exposure during different kyphoplasty techniques.

    Science.gov (United States)

    Panizza, Denis; Barbieri, Massimo; Parisoli, Francesco; Moro, Luca

    2014-01-01

    The scope of this study was to quantify patient radiation exposure during two different techniques of kyphoplasty (KP), which differ by a cement delivery method, in order to assess whether or not one of the two used methods can reduce the patient dose. Twenty patients were examined for this investigation. One X-ray fluoroscopy unit was used for localization, navigation and monitoring of cement delivery. The patient biometric data, the setting of the fluoroscope, the exposure time and the kerma-area product (KAP) were monitored in all the procedures for anteroposterior (AP) and lateral (LL) fluoroscopic projections in order to assess the range of radiation doses imparted to the patient. Theoretical entrance skin dose (ESD) and effective dose (E) were calculated from intraoperatively measured KAP. An average ET per procedure was 1.5±0.5 min for the manual injection technique (study A) and 1.4±0.4 min for the distance delivery technique (study B) in the AP plane, while 3.2±0.7 and 5.1±0.6 min in the lateral plane, respectively. ESD was estimated as an average of 0.10±0.06 Gy for study A and 0.13±0.13 Gy for study B in the AP or/and 0.59±0.46 and 1.05±0.36 Gy in the lateral view, respectively. The cumulative mean E was 1.9±1.0 mSv procedure(-1) for study A and 3.6±0.9 mSv procedure(-1) for study B. Patient radiation exposure and associated effective dose from KP may be considerable. The technique of distance cement delivery appears to be slower than the manual injection technique and it requires a more protracted fluoroscopic control in the lateral projection, so that this system entails a higher amount of dose to the patient.

  13. Mammography accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, P.

    1993-12-31

    In the mid-1980`s, the movement toward the use of dedicated mammography equipment provided significant improvement in breast cancer detection. However, several studies demonstrated that this change was not sufficient to ensure optimal image quality at a low radiation dose. In particular, the 1985 Nationwide Evaluation of X-ray Trends identified the wide variations in image quality and radiation dose, even from dedicated units. During this time period, the American Cancer Society (ACS) launched its Breast Cancer Awareness Screening Campaign. However, there were concerns about the ability of radiology to respond to the increased demand for optimal screening examinations that would result from the ACS program. To respond to these concerns, the ACS and the American College of Radiology (ACR) established a joint committee on mammography screening in 1986. After much discussion, it was decided to use the ACR Diagnostic Practice Accreditation Program as a model for the development of a mammography accreditation program. However, some constraints were required in order to make the program meet the needs of the ACS. This voluntary, peer review program had to be timely and cost effective. It was determined that the best way to address these needs would be to conduct the program by mail. Finally, by placing emphasis on the educational nature of the program, it would provide an even greater opportunity for improving mammographic quality. The result of this effort was that, almost six years ago, in May 1987, the pilot study for the ACR Mammography Accreditation Program (MAP) began, and in August of that year, the first applications were received. In November 1987, the first 3-year accreditation certificates were awarded.

  14. Mammography accreditation program

    International Nuclear Information System (INIS)

    Wilcox, P.

    1993-01-01

    In the mid-1980's, the movement toward the use of dedicated mammography equipment provided significant improvement in breast cancer detection. However, several studies demonstrated that this change was not sufficient to ensure optimal image quality at a low radiation dose. In particular, the 1985 Nationwide Evaluation of X-ray Trends identified the wide variations in image quality and radiation dose, even from dedicated units. During this time period, the American Cancer Society (ACS) launched its Breast Cancer Awareness Screening Campaign. However, there were concerns about the ability of radiology to respond to the increased demand for optimal screening examinations that would result from the ACS program. To respond to these concerns, the ACS and the American College of Radiology (ACR) established a joint committee on mammography screening in 1986. After much discussion, it was decided to use the ACR Diagnostic Practice Accreditation Program as a model for the development of a mammography accreditation program. However, some constraints were required in order to make the program meet the needs of the ACS. This voluntary, peer review program had to be timely and cost effective. It was determined that the best way to address these needs would be to conduct the program by mail. Finally, by placing emphasis on the educational nature of the program, it would provide an even greater opportunity for improving mammographic quality. The result of this effort was that, almost six years ago, in May 1987, the pilot study for the ACR Mammography Accreditation Program (MAP) began, and in August of that year, the first applications were received. In November 1987, the first 3-year accreditation certificates were awarded

  15. The role of the EPA radiation quality assurance program in the measurement quality assurance accreditation program for radioassay laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Grady, T.M. [Environmental Monitoring Systems Laboratory, Las Vegas, NV (United States)

    1993-12-31

    As the nature and extent of radiological contamination becomes better documented and more public, radioanalytical laboratories are faced with a constantly expanding variety of new and difficult analytical requirements. Concurrent with those requirements is the responsibility to provide customers, regulatory officials, or the public with defensible data produced in an environment of verifiable, controlled quality. To meet that need, a quality assurance accreditation program for radioassay laboratories has been proposed by the American National Standards Institute (ANSI). The standard will provide the organizational framework and functional requirements needed to assure the quality of laboratory outputs. Under the proposed program, the U.S. Environmental Protection Agency`s (EPA`s) Laboratory Intercomparison Program plays a key role as a reference laboratory. The current and proposed roles of the EPA Intercomparison Program are discussed, as are the functional relationships between EPA, the accreditating organization, and the service and monitoring laboratories.

  16. Accredited Birth Centers

    Science.gov (United States)

    ... Danbury, CT 06810 203-748-6000 Accredited Since March 1998 Corvallis Birth & Women's Health Center Accredited 2314 NW Kings Blvd, Suite ... Washington, DC 20002 202-398-5520 Accredited Since March 2001 Flagstaff Birth and Women's Center Accredited 401 West Aspen Avenue Flagstaff, AZ ...

  17. Use of imaging techniques in radiation oncology

    International Nuclear Information System (INIS)

    Borras, C.; Rudder, D.; Jimenez, P.

    2002-01-01

    Imaging techniques are used in radiation oncology for: disease diagnosis, tumor localization and staging, treatment simulation, treatment planning, clinical dosimetry displays, treatment verification and patient follow up. In industrialized countries, up to the 1970's, conventional radiology was used for diagnosis, simulation and planning. Gamma cameras helped tumor staging by detecting metastases. In the 1970's, simulators were developed for exclusive use in radiation oncology departments. Clinical dosimetry displays consisted mainly in axial dose distributions. Treatment verification was done placing films in the radiation beam with the patient under treatment. In the 1980's, 2-D imaging was replaced by 3-D displays with the incorporation of computerized tomography (CT) scanners, and in the 1990's of magnetic resonance imagers (MRI). Ultrasound units, briefly used in the 1960's for treatment planning purposes, were found again useful, mainly for brachytherapy dosimetry. Digital portal imagers allowed accurate treatment field verification. Treatment planning systems incorporated the capability of 'inverse planning', i.e. once the desired dose distribution is decided, the field size, gantry, collimator and couch angles, etc, can be automatically selected. At the end of the millennium, image fusion permitted excellent anatomical display of tumors and adjacent sensitive structures. The 2000's are seeing a change from anatomical to functional imaging with the advent of MRI units capable of spectroscopy at 3 Tesla and positron emission tomography (PET) units. In 2001 combined CT/PET units appeared in RT departments. In 2002, fusion of CT, MRI and PET images became available. Molecular imaging is being developed. The situation in developing countries is quite different. To start with, cancer incidence is different in developing and in industrialized countries. In addition, the health services pattern is different: Cancer treatment is mostly done in public institutions

  18. Techniques for materials research with synchrotron radiation x-rays

    International Nuclear Information System (INIS)

    Bowen, D.K.

    1983-01-01

    A brief introductory survey is presented of the properties and generation of synchrotron radiation and the main techniques developed so far for its application to materials problems. Headings are:synchrotron radiation; X-ray techniques in synchrotron radiation (powder diffraction; X-ray scattering; EXAFS (Extended X-ray Absorption Fine Structure); X-ray fluorescent analysis; microradiography; white radiation topography; double crystal topography); future developments. (U.K.)

  19. DOE standard: The Department of Energy Laboratory Accreditation Program administration

    International Nuclear Information System (INIS)

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP), organizational responsibilities, and the accreditation process. DOELAP evaluates and accredits personnel dosimetry and radiobioassay programs used for worker monitoring and protection at DOE and DOE contractor sites and facilities as required in Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection. The purpose of this technical standard is to establish procedures for administering DOELAP and acquiring accreditation

  20. Radiation detection technique on the fishery foods

    International Nuclear Information System (INIS)

    Oikawa, Hiroshi; Satomi, Masataka; Nakamura, Koji; Yano, Yutaka

    1999-01-01

    Recently irradiation of fishery products such as sea bream, lobster etc has been spreading in South-east Asia. It is thus necessary to establish a detection technique for irradiated foods . This study aimed to investigate the effects of irradiation on the production of tyrosine isomers with relation to the status of food sample (frozen and cold-storage) and also the stabilities of the isomers in frozen foods after irradiation. Production of tyrosin isomers (meta-tyrosine, ortho-tyrosine) due to γ-ray irradiation (5 kGy) were observed in the muscles of frozen prawns as well as those at room temperature and the contents of these isomers after the irradiation was not different between the two states of the sample. The content increased depending on the radiation dose. The contents of these tyrosine isomers were not changed after storage at -20degC for 120 days. Therefore, it was thought that the tyrosine isomers were available as an effective indicator for detection of an irradiated food. (M.N.)

  1. Review of the afterloading techniques in gynecologic radiation therapy

    International Nuclear Information System (INIS)

    Rotte, K.

    1975-01-01

    A review of clinically used afterloading techniques - remote controlled and manually operated ones - is given by tables. The advantages of afterloading techniques are discussed with regard to radiation protection as well as to the therapy of gynecologic carcinomas. (orig.) [de

  2. Radiation technique for the destruction of plutella

    International Nuclear Information System (INIS)

    1980-01-01

    Plutella can be destroyed by cultivation technique where cabbage is grown interchangebly with other plants, biological technique where the natural enemy of plutella is used, and chemical technique where insecticide is used. Those method do not better results than the sterile male technique which can be either nuclear or chemical in nature. Laboratory, semifield research, and research in a limited field have been carried out when applying the sterile male technique. (SMN)

  3. Radiation ionization is an underestimated industrial technique

    International Nuclear Information System (INIS)

    Anon.

    1999-01-01

    Industrial radiation ionization requires electron beams coming from an accelerator or gamma radiation from a radioactive source (Co 60 ). The energy deposed in the irradiated material modifies its chemical bounds or kills micro-organisms. This process is used in medical material sterilization, in disinfestation of stored and packaged food products, in the production of plastic, in the coloring of glass, in the hardening of electronic components and in the modification of the properties of semi-conductors. For 40 years radiation ionization has been investigated, UNO (United Nations Organization) and WHO (World Health Organisation) recommend it for food processing. With a growing rate of 15% per year for the last 15 years, radiation ionization is now widely used. More than 170 gamma irradiation facilities are operating throughout the world. (A.C.)

  4. Cytogenetic techniques as biological indicator and dosimeter of radiation damage

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Hristova, R.

    2006-01-01

    Full text: The cytogenetic methods are established techniques for bio monitoring and bio dosimetry of professionally and accidentally exposed to ionizing radiation subjects. They are applied to continue the evaluation of the physical dosimetry and to consider the individual radiosensitivity. The results of cytogenetic monitoring and dosimetry of radiation exposed subjects carried out during the last 5 years in laboratory of Radiation Genetics, NCRRP is reported. Laboratory of Radiation genetics performs cytogenetic monitoring of low dose radiation professionally or medically exposed subjects: workers in Kozloduy NPP, radioactive waste repository workers, X-rays diagnostically exposed patients, and radiotherapy exposed as well. Three cytogenetic indicators are applied as the most sensitive indicators for human radiation exposure: analysis of micronuclei (MN), chromosomal aberrations (CA) and stable translocations (FISH). The optimized methodology for application of different cytogenetic techniques for radiation estimation is discussed

  5. Radiation techniques in the formulation of synthetic biomaterials

    International Nuclear Information System (INIS)

    Kaetsu, Isao

    1992-01-01

    This chapter reviews the uses of various radiation techniques, such as radiation polymerization, grafting, and crosslinking, for the formulation of synthetic biomaterials. The biomaterials are divided into four categories: Biocompatible polymers, immobilized proteins, immobilized cells, and drug delivery systems. The recent achievements in each category are described, and the contributions of novel radiation techniques to this field are discussed. Work on drug delivery systemsis also reviewed, and the status of the practical applications of drug delivery systems for therapy is summarized. Future trends in the field of radiation-synthesized biomaterials are indicated. (orig.)

  6. Development of Radiation Technique for Environmental Treatment

    International Nuclear Information System (INIS)

    Lee, Myun Joo; Kuk, Il Hiun; Jin, Joon Ha

    2007-02-01

    The purpose of this research is to development of technologies for 1) the removal of toxic organic chemicals in sewage sludges and the volume reduction of the sewage sludge 2) the recycling/reuse of sewage sludge 3) the reconvey of resource from fishery waste by using radiation technologies. This research project focused on the study of treatment, disposal, and recycling/reuse of sewage sludge by radiation technology, and recovery of highly value-added resources from the wastes. As basic studies with a radiation technology, an enhancement of dewaterbilities of sewage sludge, development of dewatering conditioner, reduction of trace toxic organic chemicals, and the toxicities of the byproducts were studied. Based on the basic experimental results, we developed the pilot-scale system with the continuous e-beam and dewatering unit and the advanced treatment system with the use of carbon source recovered from sewage sludge

  7. Development of Radiation Technique for Environmental Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myun Joo; Kuk, Il Hiun; Jin, Joon Ha [and others

    2007-02-15

    The purpose of this research is to development of technologies for 1) the removal of toxic organic chemicals in sewage sludges and the volume reduction of the sewage sludge 2) the recycling/reuse of sewage sludge 3) the reconvey of resource from fishery waste by using radiation technologies. This research project focused on the study of treatment, disposal, and recycling/reuse of sewage sludge by radiation technology, and recovery of highly value-added resources from the wastes. As basic studies with a radiation technology, an enhancement of dewaterbilities of sewage sludge, development of dewatering conditioner, reduction of trace toxic organic chemicals, and the toxicities of the byproducts were studied. Based on the basic experimental results, we developed the pilot-scale system with the continuous e-beam and dewatering unit and the advanced treatment system with the use of carbon source recovered from sewage sludge.

  8. Synchrotron radiation based analytical techniques (XAS and XRF)

    International Nuclear Information System (INIS)

    Jha, Shambhu Nath

    2014-01-01

    A brief description of the principles of X-ray absorption spectroscopy (XAS) and X-ray fluorescence (XRF) techniques is given in this article with emphasis on the advantages of using synchrotron radiation-based instrumentation/beamline. XAS technique is described in more detail to emphasize the strength of the technique as a local structural probe. (author)

  9. CIEMAT external dosimetry service: ISO/IEC 17025 accreditation and 3 y of operational experience as an accredited laboratory

    International Nuclear Information System (INIS)

    Romero, A.M.; Rodriguez, R.; Lopez, J.L.; Martin, R.; Benavente, J.F.

    2016-01-01

    In 2008, the CIEMAT Radiation Dosimetry Service decided to implement a quality management system, in accordance with established requirements, in order to achieve ISO/IEC 17025 accreditation. Although the Service comprises the approved individual monitoring services of both external and internal radiation, this paper is specific to the actions taken by the External Dosimetry Service, including personal and environmental dosimetry laboratories, to gain accreditation and the reflections of 3 y of operational experience as an accredited laboratory. (authors)

  10. Principles and techniques of radiation hardening. Volume 2. Transient radiation effects in electronics (TREE)

    International Nuclear Information System (INIS)

    Rudie, N.J.

    1976-01-01

    The three-volume book is intended to serve as a review of the effects of thermonuclear explosion induced radiation (x-rays, gamma rays, and beta particles) and the resulting electromagnetic pulse (EMP). Volume 2 deals with the following topics: radiation effects on quartz crystals, tantalum capacitors, bipolar semiconductor devices and integrated circuits, field effect transistors, and miscellaneous electronic devices; hardening electronic systems to photon and neutron radiation; nuclear radiation source and/or effects simulation techniques; and radiation dosimetry

  11. Automation of scanning technique by gamma radiation

    International Nuclear Information System (INIS)

    Aamira, Yahya

    2011-01-01

    The gamma scan technique is a nuclear test allowing the analysis of the internal mechanical properties of distillation columns used in petrochemical industries. Such technique is performed manually. So we propose in this work to automate the gamma scan procedure test by using a PLC. In addition, supervision and data acquisition interfaces are proposed.

  12. Strengthening organizational performance through accreditation research-a framework for twelve interrelated studies: the ACCREDIT project study protocol

    Directory of Open Access Journals (Sweden)

    Pope Catherine

    2011-10-01

    Full Text Available Abstract Background Service accreditation is a structured process of recognising and promoting performance and adherence to standards. Typically, accreditation agencies either receive standards from an authorized body or develop new and upgrade existing standards through research and expert views. They then apply standards, criteria and performance indicators, testing their effects, and monitoring compliance with them. The accreditation process has been widely adopted. The international investments in accreditation are considerable. However, reliable evidence of its efficiency or effectiveness in achieving organizational improvements is sparse and the value of accreditation in cost-benefit terms has yet to be demonstrated. Although some evidence suggests that accreditation promotes the improvement and standardization of care, there have been calls to strengthen its research base. In response, the ACCREDIT (Accreditation Collaborative for the Conduct of Research, Evaluation and Designated Investigations through Teamwork project has been established to evaluate the effectiveness of Australian accreditation in achieving its goals. ACCREDIT is a partnership of key researchers, policymakers and agencies. Findings We present the framework for our studies in accreditation. Four specific aims of the ACCREDIT project, which will direct our findings, are to: (i evaluate current accreditation processes; (ii analyse the costs and benefits of accreditation; (iii improve future accreditation via evidence; and (iv develop and apply new standards of consumer involvement in accreditation. These will be addressed through 12 interrelated studies designed to examine specific issues identified as a high priority. Novel techniques, a mix of qualitative and quantitative methods, and randomized designs relevant for health-care research have been developed. These methods allow us to circumvent the fragmented and incommensurate findings that can be generated in small

  13. Strengthening organizational performance through accreditation research-a framework for twelve interrelated studies: the ACCREDIT project study protocol.

    Science.gov (United States)

    Braithwaite, Jeffrey; Westbrook, Johanna; Johnston, Brian; Clark, Stephen; Brandon, Mark; Banks, Margaret; Hughes, Clifford; Greenfield, David; Pawsey, Marjorie; Corbett, Angus; Georgiou, Andrew; Callen, Joanne; Ovretveit, John; Pope, Catherine; Suñol, Rosa; Shaw, Charles; Debono, Deborah; Westbrook, Mary; Hinchcliff, Reece; Moldovan, Max

    2011-10-09

    Service accreditation is a structured process of recognising and promoting performance and adherence to standards. Typically, accreditation agencies either receive standards from an authorized body or develop new and upgrade existing standards through research and expert views. They then apply standards, criteria and performance indicators, testing their effects, and monitoring compliance with them. The accreditation process has been widely adopted. The international investments in accreditation are considerable. However, reliable evidence of its efficiency or effectiveness in achieving organizational improvements is sparse and the value of accreditation in cost-benefit terms has yet to be demonstrated. Although some evidence suggests that accreditation promotes the improvement and standardization of care, there have been calls to strengthen its research base.In response, the ACCREDIT (Accreditation Collaborative for the Conduct of Research, Evaluation and Designated Investigations through Teamwork) project has been established to evaluate the effectiveness of Australian accreditation in achieving its goals. ACCREDIT is a partnership of key researchers, policymakers and agencies. We present the framework for our studies in accreditation. Four specific aims of the ACCREDIT project, which will direct our findings, are to: (i) evaluate current accreditation processes; (ii) analyse the costs and benefits of accreditation; (iii) improve future accreditation via evidence; and (iv) develop and apply new standards of consumer involvement in accreditation. These will be addressed through 12 interrelated studies designed to examine specific issues identified as a high priority. Novel techniques, a mix of qualitative and quantitative methods, and randomized designs relevant for health-care research have been developed. These methods allow us to circumvent the fragmented and incommensurate findings that can be generated in small-scale, project-based studies. The overall

  14. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  15. Nuclear and radiation techniques - state of art and development trends

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1995-01-01

    The state of art and development trends of nuclear and radiation techniques in Poland and worldwide have been presented. Among them the radiometric gages, radiation technologies, radiotracer methods and measuring systems for pipeline and vessels, brightness control have been described and their applications in industry, agriculture, health and environment protection have been shown and discussed. 35 refs, 1 fig

  16. Techniques for predicting environment electromagnetic radiation at satellite ground station

    International Nuclear Information System (INIS)

    Xu Peiji

    1987-01-01

    The measurement theories, techniques, and calculation methods on public exposure level of electromagnetic radiation at satellite ground station are described for the purpose of enviroment protection and research of EM compatibility. According to the results of the measurement and calculation, it is possible to predict the effects of electromagnetic radiation to environment at satellite ground station

  17. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    1975-10-01

    'Risk of damage' and 'exposure risk' are considered as components of the radiation risk. The influence of the 'exposure risk' on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Basing upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high 'exposure risk'. As a consequence the following recommendations are given for discussion: (a) occupationally exposed persons with small 'exposure risk' should be monitored using only a long-term dosimeter (for instance a thermoluminescence dosimeter), (b) in the case of internal exposure the surface and, if necessary, air contamination should be controlled so strictly that routine measurements of internal contamination need not be performed. (author)

  18. Radiation technologies and techniques friendly for environment and men

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Walis, L.

    1995-01-01

    Development of radiation technologies and techniques in Poland has been shown. Especially thermoshrinkable olefins with shape memory, fast thermistors and radiation sterilization have been presented. Also the radiometric gages produced in the Institute of Nuclear Chemistry and Technology, Warsaw for air monitoring have been described. A broad group of radiotracer techniques being used for environmental study have been presented as well. Radiation technologies with electron beam use for flue gas purification, sewage sludge hygienization and food processing have been shown and their development has been discussed

  19. Dose levels of the occupational radiation exposures in Poland based on results from the accredited dosimetry service at the IFJ PAN, Krakow.

    Science.gov (United States)

    Budzanowski, Maciej; Kopeć, Renata; Obryk, Barbara; Olko, Paweł

    2011-03-01

    Individual dosimetry service based on thermoluminescence (TLD) detectors has started its activity at the Institute of Nuclear Physics (IFJ) in Krakow in 1965. In 2002, the new Laboratory of Individual and Environment Dosimetry (Polish acronym LADIS) was established and underwent the accreditation according to the EN-PN-ISO/IEC 17025 standard. Nowadays, the service is based on the worldwide known standard thermoluminescent detectors MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P), developed at IFJ, processed in automatic thermoluminescent DOSACUS or RE2000 (Rados Oy, Finland) readers. Laboratory provides individual monitoring in terms of personal dose equivalent H(p)(10) and H(p)(0.07) in photon and neutron fields, over the range from 0.1 mSv to 1 Sv, and environmental dosimetry in terms of air kerma K(a) over the range from 30 μGy to 1 Gy and also ambient dose equivalent H*(10) over the range from 30 μSv to 1 Sv. Dosimetric service is currently performed for ca. 3200 institutions from Poland and abroad, monitored on quarterly and monthly basis. The goal of this paper is to identify the main activities leading to the highest radiation exposures in Poland. The paper presents the results of statistical evaluation of ∼ 100,000 quarterly H(p)(10) and K(a) measurements performed between 2002 and 2009. Sixty-five per cent up to 90 % of all individual doses in Poland are on the level of natural radiation background. The dose levels between 0.1 and 5 mSv per quarter are the most frequent in nuclear medicine, veterinary and industrial radiography sectors.

  20. Hybrid hydrogels produced by ionizing radiation technique

    Science.gov (United States)

    Oliveira, M. J. A.; Amato, V. S.; Lugão, A. B.; Parra, D. F.

    2012-09-01

    The interest in biocompatible hydrogels with particular properties has increased considerably in recent years due to their versatile applications in biomedicine, biotechnology, pharmacy, agriculture and controlled release of drugs. The use of hydrogels matrices for particular drug-release applications has been investigated with the synthesis of modified polymeric hydrogel of PVAl and 0.5, 1.0, 1.5% nano-clay. They were processed using gamma radiation from Cobalt-60 source at 25 kGy dose. The characterization of the hydrogels was conducted and toxicity was evaluated. The dried hydrogel was analyzed for thermogravimetry analysis (TGA), infrared spectroscopy (FTIR) and swelling in solutions of different pH. The membranes have no toxicity. The nano-clay influences directly the equilibrium swelling.

  1. Components of laboratory accreditation.

    Science.gov (United States)

    Royal, P D

    1995-12-01

    Accreditation or certification is a recognition given to an operation or product that has been evaluated against a standard; be it regulatory or voluntary. The purpose of accreditation is to provide the consumer with a level of confidence in the quality of operation (process) and the product of an organization. Environmental Protection Agency/OCM has proposed the development of an accreditation program under National Environmental Laboratory Accreditation Program for Good Laboratory Practice (GLP) laboratories as a supplement to the current program. This proposal was the result of the Inspector General Office reports that identified weaknesses in the current operation. Several accreditation programs can be evaluated and common components identified when proposing a structure for accrediting a GLP system. An understanding of these components is useful in building that structure. Internationally accepted accreditation programs provide a template for building a U.S. GLP accreditation program. This presentation will discuss the traditional structure of accreditation as presented in the Organization of Economic Cooperative Development/GLP program, ISO-9000 Accreditation and ISO/IEC Guide 25 Standard, and the Canadian Association for Environmental Analytical Laboratories, which has a biological component. Most accreditation programs are managed by a recognized third party, either privately or with government oversight. Common components often include a formal review of required credentials to evaluate organizational structure, a site visit to evaluate the facility, and a performance evaluation to assess technical competence. Laboratory performance is measured against written standards and scored. A formal report is then sent to the laboratory indicating accreditation status. Usually, there is a scheduled reevaluation built into the program. Fee structures vary considerably and will need to be examined closely when building a GLP program.

  2. Gamma Radiation-Induced Template Polymerization Technique

    International Nuclear Information System (INIS)

    Siyam, T.

    2005-01-01

    Gamma radiation induced copolymerization of acrylamide sodiumacrylate (AM-AANa) in the presence and absence of the polymer additive was studied at low monomer concentration(1.4M/l). The results showed that the exponents of the dose rate for the polymerization rate was found to be 1.3 and 1.4 in the absence and in the presence of the polymer additive respectively. The molecular weight of the formed polymer increased by addition of the polymer to the system. In the presence of the polymer the comonomers polymerize on the added polymer. In the absence of the added polymer the comonomers polymerize according to the copolymerization process at the initial stage of the copolymerization. While at high conversion the residual comonomers polymerize on the formed macromolecular chains of the produced polymer. These studies showed that the copolymerization in the presence of added polymer is completely template copolymerization while in the absence of the polymer the copolymerization process is only template process with a high conversion

  3. Hybrid hydrogels produced by ionizing radiation technique

    International Nuclear Information System (INIS)

    Oliveira, M.J.A.; Amato, V.S.; Lugão, A.B.; Parra, D.F.

    2012-01-01

    The interest in biocompatible hydrogels with particular properties has increased considerably in recent years due to their versatile applications in biomedicine, biotechnology, pharmacy, agriculture and controlled release of drugs. The use of hydrogels matrices for particular drug-release applications has been investigated with the synthesis of modified polymeric hydrogel of PVAl and 0.5, 1.0, 1.5% nano-clay. They were processed using gamma radiation from Cobalt-60 source at 25 kGy dose. The characterization of the hydrogels was conducted and toxicity was evaluated. The dried hydrogel was analyzed for thermogravimetry analysis (TGA), infrared spectroscopy (FTIR) and swelling in solutions of different pH. The membranes have no toxicity. The nano-clay influences directly the equilibrium swelling. - Highlights: ► Chemical interaction is observed when nanoclay is irradiated in PVAl hybrid hydrogels. ► Osmotic pressure within network promotes the rehydration capacity of the membranes. ► This effect is an important characteristic for hydrogels drug delivery systems.

  4. Health Physics Society program for accreditation of calibration laboratories

    International Nuclear Information System (INIS)

    West, L.; Masse, F.X.; Swinth, K.L.

    1988-01-01

    The Health Physics Society has instituted a new program for accreditation of organizations that calibrate radiation survey instruments. The purpose of the program is to provide radiation protection professionals with an expanded means of direct and indirect access to national standards, thus introducing a means for improving the uniformity, accuracy, and quality of ionizing radiation field measurements. Secondary accredited laboratories are expected to provide a regional support basis. Tertiary accredited laboratories are expected to operate on a more local basis and provide readily available expertise to end users. The accreditation process is an effort to provide better measurement assurance for surveys of radiation fields. The status of the accreditation program, general criteria, gamma-ray calibration criteria, and x-ray calibration criteria are reviewed

  5. Radiation detection technique on the fishery foods

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Koji; Yano, Yutaka; Oikawa, Hiroshi [National Research Inst. of Fisheries Science, Yokohama (Japan)

    2000-02-01

    When muscles and myofibril are irradiated by gamma ray, Mg-ATPase activity increased with increasing of dose, but EDTA-ATPase decreased. If dose is very large, Ca-ATPase activity increased. The effects of state of protein on these phenomena were investigated. The muscles, myofibril and myosin B of Tilapia nilotica were used as samples. Change of Ca-ATPase, Mg-ATPase and EDTA-ATPase activity of myosin B by gamma-ray irradiation was the same as myofibril and muscles, but myosin B showed high sensitivity and each ATPase activity was changed by low dose. Accordingly, these values were more difficult to apply to detection technique of irradiation than state of muscle and myofibril. Collagen is known to degenerate and coagulate by gamma-ray irradiation. However, amount of hot water soluble collagen was increased with increasing of dose. (S.Y.)

  6. Development of Plant Application Technique of Low Dose Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Byung Yeoup; Kim, Jae Sung; Lim, Yong Taek (and others)

    2007-07-15

    The project was carried out to achieve three aims. First, development of application techniques of cell-stimulating effects by low-dose radiation. Following irradiation with gamma-rays of low doses, beneficial effects in crop germination, early growth, and yield were investigated using various plant species and experimental approaches. For the actual field application, corroborative studies were also carried out with a few concerned experimental stations and farmers. Moreover, we attempted to establish a new technique of cell cultivation for industrial mass-production of shikonin, a medicinal compound from Lithospermum erythrorhizon and thereby suggested new application fields for application techniques of low-dose radiation. Second, elucidation of action mechanisms of ionizing radiation in plants. By investigating changes in plant photosynthesis and physiological metabolism, we attempted to elucidate physiological activity-stimulating effects of low-dose radiation and to search for radiation-adaptive cellular components. Besides, analyses of biochemical and molecular biological mechanisms for stimulus-stimulating effects of low-dose radiation were accomplished by examining genes and proteins inducible by low-dose radiation. Third, development of functional crop plants using radiation-resistant factors. Changes in stress-tolerance of plants against environmental stress factors such as light, temperature, salinity and UV-B stress after exposed to low-dose gamma-rays were investigated. Concerned reactive oxygen species, antioxidative enzymes, and antioxidants were also analyzed to develop high value-added and environment-friendly functional plants using radiation-resistant factors. These researches are important to elucidate biological activities increased by low-dose radiation and help to provide leading technologies for improvement of domestic productivity in agriculture and development of high value-added genetic resources.

  7. Development of Plant Application Technique of Low Dose Radiation

    International Nuclear Information System (INIS)

    Chung, Byung Yeoup; Kim, Jae Sung; Lim, Yong Taek

    2007-07-01

    The project was carried out to achieve three aims. First, development of application techniques of cell-stimulating effects by low-dose radiation. Following irradiation with gamma-rays of low doses, beneficial effects in crop germination, early growth, and yield were investigated using various plant species and experimental approaches. For the actual field application, corroborative studies were also carried out with a few concerned experimental stations and farmers. Moreover, we attempted to establish a new technique of cell cultivation for industrial mass-production of shikonin, a medicinal compound from Lithospermum erythrorhizon and thereby suggested new application fields for application techniques of low-dose radiation. Second, elucidation of action mechanisms of ionizing radiation in plants. By investigating changes in plant photosynthesis and physiological metabolism, we attempted to elucidate physiological activity-stimulating effects of low-dose radiation and to search for radiation-adaptive cellular components. Besides, analyses of biochemical and molecular biological mechanisms for stimulus-stimulating effects of low-dose radiation were accomplished by examining genes and proteins inducible by low-dose radiation. Third, development of functional crop plants using radiation-resistant factors. Changes in stress-tolerance of plants against environmental stress factors such as light, temperature, salinity and UV-B stress after exposed to low-dose gamma-rays were investigated. Concerned reactive oxygen species, antioxidative enzymes, and antioxidants were also analyzed to develop high value-added and environment-friendly functional plants using radiation-resistant factors. These researches are important to elucidate biological activities increased by low-dose radiation and help to provide leading technologies for improvement of domestic productivity in agriculture and development of high value-added genetic resources

  8. Intensity-modulated radiation therapy clinical evidence and techniques

    CERN Document Server

    Nishimura, Yasumasa

    2015-01-01

    Successful clinical use of intensity-modulated radiation therapy (IMRT) represents a significant advance in radiation oncology. Because IMRT can deliver high-dose radiation to a target with a reduced dose to the surrounding organs, it can improve the local control rate and reduce toxicities associated with radiation therapy. Since IMRT began being used in the mid-1990s, a large volume of clinical evidence of the advantages of IMRT has been collected. However, treatment planning and quality assurance (QA) of IMRT are complicated and difficult for the clinician and the medical physicist. This book, by authors renowned for their expertise in their fields, provides cumulative clinical evidence and appropriate techniques for IMRT for the clinician and the physicist. Part I deals with the foundations and techniques, history, principles, QA, treatment planning, radiobiology and related aspects of IMRT. Part II covers clinical applications with several case studies, describing contouring and dose distribution with cl...

  9. Role of cytogenetic techniques in biological dosimetry of absorbed radiation

    International Nuclear Information System (INIS)

    Rao, B.S.

    2016-01-01

    In most of the radiation accidents, physical dosimetric information is rarely available. Further, most of the accidental exposures are non-uniform involving either partial body or localized exposure to significant doses. In such situations, physical dosimetry does not provide reliable dose estimate. It has now been realized that biological dosimetric techniques can play an important role in the assessment of absorbed dose. In recent years, a number of biological indicators of radiation have been identified. These include the kinetics of onset and persistence of prodromal syndromes (radiation sickness), cytogenetic changes in peripheral blood lymphocytes, hematological changes, biochemical indicators, ESR spectroscopy of biological samples, induction of gene mutations in red blood cells, cytogenetic and physiological changes in skin and neurophysiological changes. In general, dosimetric information is derived by a combination of several different methods, as they have potential to serve as prognostic indicators. The role of cytogenetic techniques in peripheral blood lymphocytes (PBL) as biological indicators of absorbed radiation is reviewed here

  10. Fundamentals - state of the art of radiation techniques

    International Nuclear Information System (INIS)

    Wogman, N.A.

    1982-01-01

    In minerals exploration and extraction, nuclear techniques have several advantages. The techniques are elementally specific and their exploration range varies from a few millimeters in average rock formations to more than a meter. Because of the heterogeneous disposition of minerals and difficult environments in which measurements are required (in boreholes, on conveyor belts, in bunkers), interrogating techniques are required which exhibit both elemental specificity and range. It is for these fundamental reasons that nuclear techniques are the only possible techniques which satisfy all requirements. A variety of techniques have been developed and used. These are based on energy dispersive x-ray fluorescence (EDXRF), measurement of natural gamma-ray radiation, gamma-ray attenuation and scattering, and on neutron interactions. This paper discusses the fundamentals of these four techniques and their applications. A table is also provided listing some existing selected applications of nuclear techniques in mineral exploration, mining and processing

  11. The regeneration of polluted active carbon by radiation techniques

    International Nuclear Information System (INIS)

    Bao Borong; Wu Minghong; Hu Longxin; Zhou Riumin; Zhu Jinliang

    1998-01-01

    In this paper, we investigated the regeneration of polluted active carbon from monosodium glutamate factory by combination of radiation and acid-alkali chemical techniques. The experimental results show that the polluted active carbon will be highly regenerated on the conditions of process concentration 3%, process time 0.5 hour and the adjustment process concentration 2%, time 0.5 hour, radiation dose 5kGy. As regeneration times increase, the regenerated active carbon behaves with good repetition and stable property

  12. Review of retrospective dosimetry techniques for external ionising radiation exposures

    International Nuclear Information System (INIS)

    Ainsbury, E. A.; Bakhanova, E.; Barquinero, J. F.; Brai, M.; Chumak, V.; Correcher, V.; Darroudi, F.; Fattibene, P.; Gruel, G.; Guclu, I.; Horn, S.; Jaworska, A.; Kulka, U.; Lindholm, C.; Lloyd, D.; Longo, A.; Marrale, M.; Monteiro Gil, O.; Oestreicher, U.; Pajic, J.; Rakic, B.; Romm, H.; Trompier, F.; Veronese, I.; Voisin, P.; Vral, A.; Whitehouse, C. A.; Wieser, A.; Woda, C.; Wojcik, A.; Rothkamm, K.

    2011-01-01

    The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic resonance, thermoluminescence, optically stimulated luminescence, neutron activation, haematology, protein biomarkers and analytical dose reconstruction. Individual characteristics of these techniques, their limitations and potential for further development are reviewed, and their usefulness in specific exposure scenarios is discussed. Whilst no single technique fulfils the criteria of an ideal dosemeter, an integrated approach using multiple techniques tailored to the exposure scenario can cover most requirements. (authors)

  13. Physics of nuclear radiations concepts, techniques and applications

    CERN Document Server

    Rangacharyulu, Chary

    2013-01-01

    Physics of Nuclear Radiations: Concepts, Techniques and Applications makes the physics of nuclear radiations accessible to students with a basic background in physics and mathematics. Rather than convince students one way or the other about the hazards of nuclear radiations, the text empowers them with tools to calculate and assess nuclear radiations and their impact. It discusses the meaning behind mathematical formulae as well as the areas in which the equations can be applied. After reviewing the physics preliminaries, the author addresses the growth and decay of nuclear radiations, the stability of nuclei or particles against radioactive transformations, and the behavior of heavy charged particles, electrons, photons, and neutrons. He then presents the nomenclature and physics reasoning of dosimetry, covers typical nuclear facilities (such as medical x-ray machines and particle accelerators), and describes the physics principles of diverse detectors. The book also discusses methods for measuring energy a...

  14. Training Accreditation Program

    International Nuclear Information System (INIS)

    1989-01-01

    The Training Accreditation Program establishes the objectives and criteria against which DOE nuclear facility training is evaluated to determine its readiness for accreditation. Training programs are evaluated against the accreditation objectives and criteria by facility personnel during the initial self-evaluation process. From this self-evaluation, action plans are made by the contractor to address the scope of work necessary in order to upgrade any deficiencies noted. This scope of work must be formally documented in the Training Program Accreditation Plan. When reviewed and approved by the responsible Head of the Field Organization and cognizant Program Secretarial Office, EH-1 concurrence is obtained. This plan then becomes the document which guides accreditation efforts for the contractor

  15. An Accurate Technique for Calculation of Radiation From Printed Reflectarrays

    DEFF Research Database (Denmark)

    Zhou, Min; Sorensen, Stig B.; Jorgensen, Erik

    2011-01-01

    The accuracy of various techniques for calculating the radiation from printed reflectarrays is examined, and an improved technique based on the equivalent currents approach is proposed. The equivalent currents are found from a continuous plane wave spectrum calculated by use of the spectral dyadic...... Green's function. This ensures a correct relation between the equivalent electric and magnetic currents and thus allows an accurate calculation of the radiation over the entire far-field sphere. A comparison to DTU-ESA Facility measurements of a reference offset reflectarray designed and manufactured...

  16. Establishment of qualities mammography according to the standard IEC-61267 in the laboratory of metrology of ionizing radiation of the National Center of Dosimetry and enlargement of the accreditation by ENAC; Establecimiento de las calidades de mamografia segun la norma IEC-61267 en el laboratorio de metrologia de radiaciones ionizantes del centro nacional de dosimetria (CND) y proceso de ampliacion de su acreditacion por ENAC

    Energy Technology Data Exchange (ETDEWEB)

    Roig Petit, F.; Mestre de Juan, V.; Alabau Albors, J.; Palma Copete, J.; Ruiz Rodriguez, J. C.; Pons Mocholi, S.

    2013-07-01

    The extension of the accreditation of the laboratory of the National Center Dosimetry (No. 58/LC10.036) by the national accreditation entity (ENAC), according to the ISO 17025 standard [2], for the standard qualities of mammography by the IEC 61267 comes to meet part of the needs that demand our health care environment in terms of radiation measuring instruments calibration. This work intends to publicize this enlargement commenting on the different phases of the process to get the accreditation. (Author)

  17. HPS instrument calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Masse, F.X; Eisenhower, E.H.; Swinth, K.L.

    1993-12-31

    The purpose of this paper is to provide an accurate overview of the development and structure of the program established by the Health Physics Society (HPS) for accrediting instrument calibration laboratories relative to their ability to accurately calibrate portable health physics instrumentation. The purpose of the program is to provide radiation protection professionals more meaningful direct and indirect access to the National Institute of Standards and Technology (NIST) national standards, thus introducing a means for improving the uniformity, accuracy, and quality of ionizing radiation field measurements. The process is designed to recognize and document the continuing capability of each accredited laboratory to accurately perform instrument calibration. There is no intent to monitor the laboratory to the extent that each calibration can be guaranteed by the program; this responsibility rests solely with the accredited laboratory.

  18. Accreditation of diagnostic imaging services in developing countries.

    Science.gov (United States)

    Jiménez, Pablo; Borrás, Cari; Fleitas, Ileana

    2006-01-01

    In recent decades, medical imaging has experienced a technological revolution. After conducting several surveys to assess the quality and safety of diagnostic imaging services in Latin America and the Caribbean, the Pan American Health Organization (PAHO) developed a basic accreditation program that can be implemented by the ministry of health of any developing country. Patterned after the American College of Radiology's accreditation program, the PAHO program relies on a national accreditation committee to establish and maintain accreditation standards. The process involves a peer review evaluation of: (1) imaging and processing equipment, (2) physician and technologist staff qualifications, (3) quality control and quality assurance programs, and (4) image quality and, where applicable, radiation dose. Public and private conventional radiography/fluoroscopy, mammography, and ultrasound services may request accreditation. The radiography/fluoroscopy accreditation program has three modules from which to choose: chest radiography, general radiography, and fluoroscopy. The national accreditation committee verifies compliance with the standards. On behalf of the ministry of health, the accreditation committee also issues a three-year accreditation certificate. As needed, the accreditation committee consults with foreign technical and clinical experts.

  19. [Accreditation of forensic laboratories].

    Science.gov (United States)

    Sołtyszewski, Ireneusz

    2010-01-01

    According to the framework decision of the European Union Council, genetic laboratories which perform tests for the benefit of the law enforcement agencies and the administration of justice are required to obtain a certificate of accreditation testifying to compliance with the PN EN ISO/IEC 17025:2005 standard. The certificate is the official confirmation of the competence to perform research, an acknowledgement of credibility, impartiality and professional independence. It is also the proof of establishment, implementation and maintenance of an appropriate management system. The article presents the legal basis for accreditation, the procedure of obtaining the certificate of accreditation and selected elements of the management system.

  20. Radiation technique in conservation of antique objects - achievement in Poland

    International Nuclear Information System (INIS)

    Perkowski, J.

    2002-01-01

    In this work the progress of the radiation technique in conservation of antique objects in Poland was presented. From two, quite different problems: radiation's disinfection or consolidation, only the first one was applied in our country. The technique of radiation disinfection and desinsection was applied only in the nine cases, in spite of numerous propaganda's information's and advertisement's actions. It were both wooden antiques (altars, sculptures, furniture), sandstone sculpture and prison footwear. In the first case it was connected with destruction of the wood's pest, in the second with bacteria which were destroying of the object inside and in the third with the elimination of the moulds, fungus and bacteria. Differ dose of gamma radiation was applied, depending on the kind and size of initial infection. The time of the operation depended on the quality of the dose rate which was connected first of all with the size and shape of the object. Decisive significance for obtained values of irregular distribution absorbed radiation dose had the type of the material in which the object was done and it's size. (author)

  1. List of Accredited Attorneys

    Data.gov (United States)

    Department of Veterans Affairs — VA accreditation is for the sole purpose of providing representation services to claimants before VA and does not imply that a representative is qualified to provide...

  2. Tales of Accreditation Woe.

    Science.gov (United States)

    Dickmeyer, Nathan

    2002-01-01

    Offers cautionary tales depicting how an "Enron mentality" infiltrated three universities and jeopardized their accreditation status. The schools were guilty, respectively, of bad bookkeeping, lack of strategy and stable leadership, and loss of academic integrity by selling degrees. (EV)

  3. List of Accredited Organizations

    Data.gov (United States)

    Department of Veterans Affairs — VA accreditation is for the sole purpose of providing representation services to claimants before VA and does not imply that a representative is qualified to provide...

  4. List of Accredited Representatives

    Data.gov (United States)

    Department of Veterans Affairs — VA accreditation is for the sole purpose of providing representation services to claimants before VA and does not imply that a representative is qualified to provide...

  5. Radiation Effects and Hardening Techniques for Spacecraft Microelectronics

    Science.gov (United States)

    Gambles, J. W.; Maki, G. K.

    2002-01-01

    The natural radiation from the Van Allen belts, solar flares, and cosmic rays found outside of the protection of the earth's atmosphere can produce deleterious effects on microelectronics used in space systems. Historically civil space agencies and the commercial satellite industry have been able to utilize components produced in special radiation hardened fabrication process foundries that were developed during the 1970s and 1980s under sponsorship of the Departments of Defense (DoD) and Energy (DoE). In the post--cold war world the DoD and DoE push to advance the rad--hard processes has waned. Today the available rad--hard components lag two-plus technology node generations behind state- of-the-art commercial technologies. As a result space craft designers face a large performance gap when trying to utilize available rad--hard components. Compounding the performance gap problems, rad--hard components are becoming increasingly harder to get. Faced with the economic pitfalls associated with low demand versus the ever increasing investment required for integrated circuit manufacturing equipment most sources of rad--hard parts have simply exited this market in recent years, leaving only two domestic US suppliers of digital rad--hard components. This paper summarizes the radiation induced mechanisms that can cause digital microelectronics to fail in space, techniques that can be applied to mitigate these failure mechanisms, and ground based testing used to validate radiation hardness/tolerance. The radiation hardening techniques can be broken down into two classes, Hardness By Process (HBP) and Hardness By Design (HBD). Fortunately many HBD techniques can be applied to commercial fabrication processes providing space craft designer with radiation tolerant Application Specific Integrated Circuits (ASICs) that can bridge the performance gap between the special HBP foundries and the commercial state-of-the-art performance.

  6. Accreditation of nuclear engineering programs

    International Nuclear Information System (INIS)

    Williamson, T.G.

    1989-01-01

    The American Nuclear Society (ANS) Professional Development and Accreditation Committee (PDAC) has the responsibility for accreditation of engineering and technology programs for nuclear and similarly named programs. This committee provides society liaison with the Accreditation Board for Engineering and Technology (ABET), is responsible for the appointment and training of accreditation visitors, nomination of members for the ABET Board and Accreditation Commissions, and review of the criteria for accreditation of nuclear-related programs. The committee is composed of 21 members representing academia and industry. The ABET consists of 19 participating bodies, primarily professional societies, and 4 affiliate bodies. Representation on ABET is determined by the size of the professional society and the number of programs accredited. The ANS, as a participating body, has one member on the ABET board, two members on the Engineering Accreditation Commission, and one on the Technology Accreditation Commission. The ABET board sets ABET policy and the commissions are responsible for accreditation visits

  7. Highlights in radiation measuring technique's - Serial Micro Channel SMC 2100

    International Nuclear Information System (INIS)

    Kandler, M.; Hoffmann, Ch.

    2002-01-01

    The Serial Micro Channel SMC 2100 offers an ''intelligent stand alone'' electronics for the radiation measuring technique's. First it is designed of being connected to a serial interface RS232 of a PC. With a RS485 serial interface on a PC, a network structure can be generated. It has all functional modules which are necessary for the measurement of detector signals. Hence it is possible to directly connect any detector for radiation measurement to a PC, laptop, or notebook. All variations can be operated without PC support too. It has a modular structure and consists of two blocks, the functional modules and the basic modules. The Serial Micro Channel SMC 2100 may be directly coupled to a detector, which therefore makes the realisation of an ''intelligent radiation detector'' with serial link RS232 or RS485. (orig.)

  8. [Accreditation of medical laboratories].

    Science.gov (United States)

    Horváth, Andrea Rita; Ring, Rózsa; Fehér, Miklós; Mikó, Tivadar

    2003-07-27

    In Hungary, the National Accreditation Body was established by government in 1995 as an independent, non-profit organization, and has exclusive rights to accredit, amongst others, medical laboratories. The National Accreditation Body has two Specialist Advisory Committees in the health care sector. One is the Health Care Specialist Advisory Committee that accredits certifying bodies, which deal with certification of hospitals. The other Specialist Advisory Committee for Medical Laboratories is directly involved in accrediting medical laboratory services of health care institutions. The Specialist Advisory Committee for Medical Laboratories is a multidisciplinary peer review group of experts from all disciplines of in vitro diagnostics, i.e. laboratory medicine, microbiology, histopathology and blood banking. At present, the only published International Standard applicable to laboratories is ISO/IEC 17025:1999. Work has been in progress on the official approval of the new ISO 15189 standard, specific to medical laboratories. Until the official approval of the International Standard ISO 15189, as accreditation standard, the Hungarian National Accreditation Body has decided to progress with accreditation by formulating explanatory notes to the ISO/IEC 17025:1999 document, using ISO/FDIS 15189:2000, the European EC4 criteria and CPA (UK) Ltd accreditation standards as guidelines. This harmonized guideline provides 'explanations' that facilitate the application of ISO/IEC 17025:1999 to medical laboratories, and can be used as a checklist for the verification of compliance during the onsite assessment of the laboratory. The harmonized guideline adapted the process model of ISO 9001:2000 to rearrange the main clauses of ISO/IEC 17025:1999. This rearrangement does not only make the guideline compliant with ISO 9001:2000 but also improves understanding for those working in medical laboratories, and facilitates the training and education of laboratory staff. With the

  9. Impacts of radiation management techniques on the North Atlantic Oscillation

    Science.gov (United States)

    Adakudlu, Muralidhar; Helge Otterå, Odd; Tjiputra, Jerry; Muri, Helene; Grini, Alf; Schulz, Michael

    2017-04-01

    The effectiveness of various climate engineering techniques in limiting the global warming signal to reasonable levels has been the topic of state-of-the-art research on climate change. Using an Earth system model, we show that these techniques have the potential to bring down the high CO2 concentration climate in RCP8.5 to a moderate climate similar to RCP4.5 in terms of global temperature. Nevertheless, their influence on the regional aspects of atmospheric circulation is not clear. The regional circulation patterns in the atmosphere are largely characterized by the natural variability modes, such as the North Atlantic Oscillation (NAO). In this study, we assess the impacts of three radiation managment techniques, namely, Stratospheric Aerosol Injection (SAI), Marine Sky Brightening (MSB) and Cirrus Cloud Thinning (CCT), on the structure and features of the NAO. The results indicate an east-northeastward shift as well as intensification of the NAO spatial pattern in the global warming scenarios of RCP4.5 and RCP8.5, with the signal being most intense in the latter. The climate engineering forcings when applied to the RCP8.5 case tend to reduce the strength of the NAO with little impact on its position. The CCT case appears to have the maximum effect on the NAO signal. The patterns of cloud radiative forcing, expressed as the difference between net radiative forcing at TOA under average conditions and clear sky conditions, reveal a northeastward shift of the radiative heating in the north Atlantic region. This implies a possible link between the changes in the NAO signal and the cloud radiative forcing.

  10. Techniques of production and analysis of polarized synchrotron radiation

    International Nuclear Information System (INIS)

    Mills, D.M.

    1992-01-01

    The use of the unique polarization properties of synchrotron radiation in the hard x-ray spectral region (E>3 KeV) is becoming increasingly important to many synchrotron radiation researchers. The radiation emitted from bending magnets and conventional (planar) insertion devices (IDs) is highly linearly polarized in the plane of the particle's orbit. Elliptically polarized x-rays can also be obtained by going off axis on a bending magnet source, albeit with considerable loss of flux. The polarization properties of synchrotron radiation can be further tailored to the researcher's specific needs through the use of specialized insertion devices such as helical and crossed undulators and asymmetrical wigglers. Even with the possibility of producing a specific polarization, there is still the need to develop x-ray optical components which can manipulate the polarization for both analysis and further modification of the polarization state. A survey of techniques for producing and analyzing both linear and circular polarized x-rays will be presented with emphasis on those techniques which rely on single crystal optical components

  11. The Stonehenge technique. A method for aligning coherent bremsstrahlung radiators

    International Nuclear Information System (INIS)

    Livingston, Ken

    2009-01-01

    This paper describes a technique for the alignment of crystal radiators used to produce high energy, linearly polarized photons via coherent bremsstrahlung scattering at electron beam facilities. In these experiments the crystal is mounted on a goniometer which is used to adjust its orientation relative to the electron beam. The angles and equations which relate the crystal lattice, goniometer and electron beam direction are presented here, and the method of alignment is illustrated with data taken at MAMI (the Mainz microtron). A practical guide to setting up a coherent bremsstrahlung facility and installing new crystals using this technique is also included.

  12. The Stonehenge technique. A method for aligning coherent bremsstrahlung radiators

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, Ken [Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom)], E-mail: k.livingston@physics.gla.ac.uk

    2009-05-21

    This paper describes a technique for the alignment of crystal radiators used to produce high energy, linearly polarized photons via coherent bremsstrahlung scattering at electron beam facilities. In these experiments the crystal is mounted on a goniometer which is used to adjust its orientation relative to the electron beam. The angles and equations which relate the crystal lattice, goniometer and electron beam direction are presented here, and the method of alignment is illustrated with data taken at MAMI (the Mainz microtron). A practical guide to setting up a coherent bremsstrahlung facility and installing new crystals using this technique is also included.

  13. The Stonehenge technique. A method for aligning coherent bremsstrahlung radiators

    Science.gov (United States)

    Livingston, Ken

    2009-05-01

    This paper describes a technique for the alignment of crystal radiators used to produce high energy, linearly polarized photons via coherent bremsstrahlung scattering at electron beam facilities. In these experiments the crystal is mounted on a goniometer which is used to adjust its orientation relative to the electron beam. The angles and equations which relate the crystal lattice, goniometer and electron beam direction are presented here, and the method of alignment is illustrated with data taken at MAMI (the Mainz microtron). A practical guide to setting up a coherent bremsstrahlung facility and installing new crystals using this technique is also included.

  14. Accreditation ISO/IEC 1705 in dosimetry: Experience and results

    International Nuclear Information System (INIS)

    Martin Garcia, R.; Navarro Bravo, T.

    2013-01-01

    The objective of this work is to present the experience in the process of accreditation of the radiation dosimetry service in which there are trials for the determination of radiation doses due to internal and external exhibitions. Is They describe the aspects that were considered for the design and development of a system of quality and results after its implementation. A review of the benefits accreditation has been reported to the organization is finally made. (Author)

  15. CIEMAT EXTERNAL DOSIMETRY SERVICE: ISO/IEC 17025 ACCREDITATION AND 3 Y OF OPERATIONAL EXPERIENCE AS AN ACCREDITED LABORATORY.

    Science.gov (United States)

    Romero, A M; Rodríguez, R; López, J L; Martín, R; Benavente, J F

    2016-09-01

    In 2008, the CIEMAT Radiation Dosimetry Service decided to implement a quality management system, in accordance with established requirements, in order to achieve ISO/IEC 17025 accreditation. Although the Service comprises the approved individual monitoring services of both external and internal radiation, this paper is specific to the actions taken by the External Dosimetry Service, including personal and environmental dosimetry laboratories, to gain accreditation and the reflections of 3 y of operational experience as an accredited laboratory. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Radiation safety in industrial applications of nuclear techniques

    International Nuclear Information System (INIS)

    Lam, E.S.

    1981-01-01

    The hazards associated with the use of industrial equipment is one of the undesirable by-products of advanced technology. The use of nuclear techniques is a good example. Due to the usefulness of such techniques, one may accept the risks involved if they can be brought down to manageable levels. Most of the nuclear techniques in use in industries in Malaysia require only minimal safety precautions as they make use of only small amounts of radioactive material. However, some large sources are also being used and safety precautions have to be strictly enforced. The management plays a critical role in these industries. The requirements for radiation safety include the monitoring of workers and work areas, the medical surveillance of workers and the provision of barriers and other safety precautions. The management should also look to the training of the workers and be prepared for any emergencies that may arise. (author)

  17. Radiation safety in industrial applications of nuclear techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lam, E S [Ministry of Health, Kuala Lumpur (Malaysia)

    1981-01-01

    The hazards associated with the use of industrial equipment is one of the undesirable by-products of advanced technology. The use of nuclear techniques is a good example. Due to the usefulness of such techniques, one may accept the risks involved if they can be brought down to manageable levels. Most of the nuclear techniques in use in industries in Malaysia require only minimal safety precautions as they make use of only small amounts of radioactive material. However, some large sources are also being used and safety precautions have to be strictly enforced. The management plays a critical role in these industries. The requirements for radiation safety include the monitoring of workers and work areas, the medical surveillance of workers and the provision of barriers and other safety precautions. The management should also look to the training of the workers and be prepared for any emergencies that may arise.

  18. Applications of radiations, radioisotopes and nuclear techniques in biotechnology

    International Nuclear Information System (INIS)

    Bhatia, C.R.

    1994-01-01

    Applications of radiations, radioisotopes and other nuclear techniques has contributed a great deal in our understanding of microbial plant and animal biochemistry and molecular biology. Electron microscopy has provided visual evidence for molecular events. Developments in cell tissue culture of both plants and animals and immunology have contributed to advances in what we now refer as biotechnology. This paper focuses on the applications in the high-tech end of biotechnology, limited to the use of recombinant-DNA techniques. Molecular identification of the genes, their cloning and horizontal transfer across the species of microbes, plants and animals and expression of the transferred genes is the major strength of modern biotechnology. The techniques described in this paper have played a significant role in the development of biotechnology. 6 refs

  19. (Re)implantation of quality system of LCR (Laboratory for Radiation Sciences) for accreditation in the standard ABNT NBR ISO/IEC 17025:2005; (Re)implantacao do sistema da qualidade do LCR para acreditacao na ABNT NBR ISO/IEC 17025:2005

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Sandro P., E-mail: leite_sp@ig.com.br [Rede Sibratec, Sao Paulo, SP (Brazil); Fernandes, Elisabeth O.; David, Mariano G.; Pires, Evandro J.; Alves, Carlos F.E.; Almeida, Carlos E. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2014-07-01

    This paper presents preparing procedure of the metrology laboratory (LABMETRO), which belongs Laboratorio de Ciencias Radiologicas of Rio de Janeiro , for postulating accreditation of its services metrology to INMETRO. This process, supported by the Technological Services Network SIBRATEC/FINEP for Radiation Protection and Dosimetry Technological Services, had as one of its aims to avoid possible technical barriers to the purchase services in the area of ionizing radiation laboratories. Accreditation will also enable the integration of services such laboratories in Brazilian Calibration Network (RBC). (author)

  20. Development of radiation techniques in the 80's

    International Nuclear Information System (INIS)

    Wiesner, L.

    1990-01-01

    The application of radiation for the purpose of sterilisation in the medical field and for the enhancement of material properties, particularly for polymer products, has been in operation for decades. Electron accelerators and gamma radiation devices are the radiation sources. The technology is clearly concentrated in Asia, especially Japan, (surface coatings and crosslinking for cable insulators). In industry, the process is commonly used in curing, drying, crosslinking, grafting and vulcanisation. Radiation technology is an increasingly important factor in the low-cost production of top quality advanced products for sophisticated areas of manufacturing. It has already been introduced in high-tech applications in the manufacture of megabit chips, which are undoubtedly one of the main reasons for Japan's leading position in that field. The Japanese industry has already set out along the road towards the manufacture of ultra-highly integrated circuits, which open up completely new opportunities in the field of data and information processing. This has been made possible by Japanese mastery of the technique of building and operating electron accelerators to provide synchrotron beams. (orig./DG) [de

  1. From Evaluation to Accreditation

    DEFF Research Database (Denmark)

    Rasmussen, Palle

    Quality was introduced as political priority in Danish higher education during the 1980ties, associated with new public management as well as with new liberalism and conservatism. As a political goal the concept of quality has a paradoxical character because it does not lay out any definite course...... of education programmes has been introduced, also in the form of a national agency with the mission of accrediting all higher education programmes. The paper discusses reasons for and problems in this approach, and the more general social functions of quality assessment and accreditation....

  2. Radiation techniques in crop and plant breeding. Multiplying the benefits

    International Nuclear Information System (INIS)

    Ahloowalia, B.S.

    1998-01-01

    World food production is based on growing a wide variety of fruits, vegetables, and crops developed through advances in science. Plant breeders have produced multiple varieties that grow well in various types of soils and under diverse climates in different regions of the world. Conventionally, this is done by sexual hybridization. This involves transferring pollen from one parent plant to another to obtain hybrids. The subsequent generations of these hybrids are grown to select plants which combine the desired characters of the parents. However, another method exists by which the genetic make-up of a given plant variety can be changed without crossing with another variety. With this method, a variety retains all its original attributes but is upgraded in one or two changed characteristics. This method is based on radiation-induced genetic changes, and its referred to as ''induced mutations''. During the past thirty years, more than 1800 mutant varieties of plants have been released, many, of which were induced with radiation. Plant tissue and cell culture (also called in vitro culture) in combination with radiation is a powerful technique to induce mutations, particularly for the improvement of vegetatively propagated crops. These crops include cassava, garlic, potato, sweet potato, yams, sugarcane, ornamentals such as chrysanthemum, carnation, roses, tulips, daffodil, and many fruits (e.g. apple, banana, plantain, citrus, date palm, grape, papaya, passion fruit, and kiwi fruit). In some of these plants, either there is no seed set (e.g. banana) or the seed progeny produces plants which do not have the right combination of the desired characteristics. These techniques are also useful in the improvement of forest trees having a long lifespan before they produce fruit and seed. This article briefly reviews advances in plant breeding techniques, with a view towards improving the transfer of technologies to more countries

  3. Advanced crystal growth techniques for thallium bromide semiconductor radiation detectors

    Science.gov (United States)

    Datta, Amlan; Becla, Piotr; Guguschev, Christo; Motakef, Shariar

    2018-02-01

    Thallium Bromide (TlBr) is a promising room-temperature radiation detector candidate with excellent charge transport properties. Currently, Travelling Molten Zone (TMZ) technique is widely used for growth of semiconductor-grade TlBr crystals. However, there are several challenges associated with this type of crystal growth process including lower yield, high thermal stress, and low crystal uniformity. To overcome these shortcomings of the current technique, several different crystal growth techniques have been implemented in this study. These include: Vertical Bridgman (VB), Physical Vapor Transport (PVT), Edge-defined Film-fed Growth (EFG), and Czochralski Growth (Cz). Techniques based on melt pulling (EFG and Cz) were demonstrated for the first time for semiconductor grade TlBr material. The viability of each process along with the associated challenges for TlBr growth has been discussed. The purity of the TlBr crystals along with its crystalline and electronic properties were analyzed and correlated with the growth techniques. Uncorrected 662 keV energy resolutions around 2% were obtained from 5 mm x 5 mm x 10 mm TlBr devices with virtual Frisch-grid configuration.

  4. Standard evaluation techniques for containment and surveillance radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1982-01-01

    Evaluation techniques used at Los Alamos for personnel and vehicle radiation monitors that safeguard nuclear material determine the worst-case sensitivity. An evaluation tests a monitor's lowest sensitivity regions with sources that have minimum emission rates. The result of our performance tests are analyzed as a binomial experiment. The number of trials that are required to verify the monitor's probability of detection is determined by a graph derived from the confidence limits for a binomial distribution. Our testing results are reported in a way that characterizes the monitor yet does not compromise security by revealing its routine performance for detecting process materials

  5. Is Gerontology Ready for Accreditation?

    Science.gov (United States)

    Haley, William E.; Ferraro, Kenneth F.; Montgomery, Rhonda J. V.

    2012-01-01

    The authors review widely accepted criteria for program accreditation and compare gerontology with well-established accredited fields including clinical psychology and social work. At present gerontology lacks many necessary elements for credible professional accreditation, including defined scope of practice, applied curriculum, faculty with…

  6. Valuing the Accreditation Process

    Science.gov (United States)

    Bahr, Maria

    2018-01-01

    The value of the National Association for Developmental Education (NADE) accreditation process is far-reaching. Not only do students and programs benefit from the process, but also the entire institution. Through data collection of student performance, analysis, and resulting action plans, faculty and administrators can work cohesively towards…

  7. Quality assurance and accreditation.

    Science.gov (United States)

    1997-01-01

    In 1996, the Joint Commission International (JCI), which is a partnership between the Joint Commission on Accreditation of Healthcare Organizations and Quality Healthcare Resources, Inc., became one of the contractors of the Quality Assurance Project (QAP). JCI recognizes the link between accreditation and quality, and uses a collaborative approach to help a country develop national quality standards that will improve patient care, satisfy patient-centered objectives, and serve the interest of all affected parties. The implementation of good standards provides support for the good performance of professionals, introduces new ideas for improvement, enhances the quality of patient care, reduces costs, increases efficiency, strengthens public confidence, improves management, and enhances the involvement of the medical staff. Such good standards are objective and measurable; achievable with current resources; adaptable to different institutions and cultures; and demonstrate autonomy, flexibility, and creativity. The QAP offers the opportunity to approach accreditation through research efforts, training programs, and regulatory processes. QAP work in the area of accreditation has been targeted for Zambia, where the goal is to provide equal access to cost-effective, quality health care; Jordan, where a consensus process for the development of standards, guidelines, and policies has been initiated; and Ecuador, where JCI has been asked to help plan an approach to the evaluation and monitoring of the health care delivery system.

  8. Accreditation of Employee Development.

    Science.gov (United States)

    Geale, John

    A British project was conducted to improve understanding of the advantages and disadvantages of certification for work-based training and to analyze factors that influence the demand for accreditation. Three studies investigated what was happening in three employment sectors: tourism (service/commercial), social services (public administration),…

  9. Techniques to maximize software reliability in radiation fields

    International Nuclear Information System (INIS)

    Eichhorn, G.; Piercey, R.B.

    1986-01-01

    Microprocessor system failures due to memory corruption by single event upsets (SEUs) and/or latch-up in RAM or ROM memory are common in environments where there is high radiation flux. Traditional methods to harden microcomputer systems against SEUs and memory latch-up have usually involved expensive large scale hardware redundancy. Such systems offer higher reliability, but they tend to be more complex and non-standard. At the Space Astronomy Laboratory the authors have developed general programming techniques for producing software which is resistant to such memory failures. These techniques, which may be applied to standard off-the-shelf hardware, as well as custom designs, include an implementation of Maximally Redundant Software (MRS) model, error detection algorithms and memory verification and management

  10. States Moving from Accreditation to Accountability. Accreditation: State School Accreditation Policies

    Science.gov (United States)

    Wixom, Micah Ann

    2014-01-01

    Accreditation policies vary widely among the states. Since Education Commission of the States last reviewed public school accreditation policies in 1998, a number of states have seen their legislatures take a stronger role in accountability--resulting in a move from state-administered accreditation systems to outcomes-focused state accountability…

  11. Onsite assessments for the Department of Energy Laboratory Accreditation Program

    International Nuclear Information System (INIS)

    McMahan, K.L.

    1992-01-01

    For Department of Energy (DOE) facilities, compliance with DOE Order 5480.11 became a requirement in January 1989. One of the requirements of this Order is that personal external dosimetry programs be accredited under the Department of Energy's Laboratory Accreditation Program (DOELAP) in Personnel Dosimetry. The accreditation process, from the facility's perspective, is two-fold: dosimeters must meet performance criteria in radiation categories appropriate for each facility, and personnel administering and carrying out the program must demonstrate good operating practices. The DOELAP onsite assessment is designed to provide an independent evaluation of the latter

  12. Is gerontology ready for accreditation?

    Science.gov (United States)

    Haley, William E; Ferraro, Kenneth F; Montgomery, Rhonda J V

    2012-01-01

    The authors review widely accepted criteria for program accreditation and compare gerontology with well-established accredited fields including clinical psychology and social work. At present gerontology lacks many necessary elements for credible professional accreditation, including defined scope of practice, applied curriculum, faculty with applied professional credentials, and resources necessary to support professional credentialing review. Accreditation with weak requirements will be dismissed as "vanity" accreditation, and strict requirements will be impossible for many resource-poor programs to achieve, putting unaccredited programs at increased risk for elimination. Accreditation may be appropriate in the future, but it should be limited to professional or applied gerontology, perhaps for programs conferring bachelor's or master's degrees. Options other than accreditation to enhance professional skills and employability of gerontology graduates are discussed.

  13. Radiation synthesized protein-based nanoparticles: A technique overview

    International Nuclear Information System (INIS)

    Varca, Gustavo H.C.; Perossi, Gabriela G.; Grasselli, Mariano; Lugão, Ademar B.

    2014-01-01

    Seeking for alternative routes for protein engineering a novel techniqueradiation induced synthesis of protein nanoparticles – to achieve size controlled particles with preserved bioactivity has been recently reported. This work aimed to evaluate different process conditions to optimize and provide an overview of the technique using γ-irradiation. Papain was used as model protease and the samples were irradiated in a gamma cell irradiator in phosphate buffer (pH=7.0) containing ethanol (0–35%). The dose effect was evaluated by exposure to distinct γ-irradiation doses (2.5, 5, 7.5 and 10 kGy) and scale up experiments involving distinct protein concentrations (12.5–50 mg mL −1 ) were also performed. Characterization involved size monitoring using dynamic light scattering. Bityrosine detection was performed using fluorescence measurements in order to provide experimental evidence of the mechanism involved. Best dose effects were achieved at 10 kGy with regard to size and no relevant changes were observed as a function of papain concentration, highlighting very broad operational concentration range. Bityrosine changes were identified for the samples as a function of the process confirming that such linkages play an important role in the nanoparticle formation. - Highlights: • Synthesis of protein-based nanoparticles by γ-irradiation. • Optimization of the technique. • Overview of mechanism involved in the nanoparticle formation. • Engineered papain nanoparticles for biomedical applications

  14. Application of PSA techniques to synchrotron radiation source facilities

    International Nuclear Information System (INIS)

    Sanyasi Rao, V.V.S.; Vinod, G.; Vaze, K.K.; Sarkar, P.K.

    2011-01-01

    Synchrotron radiation sources are increasingly being used in research and medical applications. Various instances of overexposure in these facilities have been reported in literature. These instances have lead to the investigation of the risks associated with them with a view to minimise the risks and thereby increasing the level of safety. In nuclear industry, Probabilistic Safety Assessment (PSA) methods are widely used to assess the risk from nuclear power plants. PSA presents a systematic methodology to evaluate the likelihood of various accident scenarios and their possible consequences using fault/event tree techniques. It is proposed to extend similar approach to analyse the risk associated with synchrotron radiation sources. First step for such an analysis is establishing the failure criteria, considering the regulatory stipulations on acceptable limits of dose due to ionization radiation from normal as well as beam loss scenarios. Some possible scenarios considered in this study are (1) excessive Bremsstrahlung in the ring due to loss of vacuum, (2) Target failure due to excessively focused beam (3) mis-directed/mis-steered beam (4) beam loss and sky shine. Hazard analysis needs to cover the beam transfer line, storage ring and experimental beam line areas. Various safety provisions are in place to minimize the hazards from these facilities such as access control interlock systems, radiation shielding for storage ring and beam lines and safety shutters (for beam lines). Experimental beam line area is the most vulnerable locations that need to be critically analysed. There are multiple beam lines, that have different safety provisions and consequences from postulated beam strikes will also be different and this increases the complexity of analysis. Similar studies conducted for such experimental facilities have identified that the radiation safety interlock system, used to control access to areas inside ring and the hutches of beamline facilities has an

  15. Accreditation and Participatory Design

    DEFF Research Database (Denmark)

    Simonsen, Jesper; Scheuer, John Damm

    2016-01-01

    This paper presents a soft project management paradigm approach based on participatory design to assuring values and benefits in public projects. For more than a decade, quality development in the Danish healthcare sector has been managed with an accreditation system known as the Danish Quality......-driven IT development and suggest how this approach may form a cornerstone of project management in a new quality-assurance program for the Danish healthcare sector....

  16. Overview of novel techniques for radiation protection and dosimetry

    International Nuclear Information System (INIS)

    Agosteo, Stefano

    2010-01-01

    Generally, the main approaches for assessing the radiation protection (RP) quantities in neutron fields are: i) the use of an instrument with a response to the protection quantity quasi-independent of energy; ii) neutron spectrometry; iii) microdosimetry. The techniques based on the first approach include rem-meters, superheated emulsions and the electronic personal dosemeters. Passive rem-meters have recently been developed for assessing the ambient dose equivalent in pulsed neutron fields around particle accelerators for hadrontherapy and research. Most of these instruments are characterised by a response extended to high-energies (up to a few GeV). An example is given by the GSI-ball, which employs a pair of LiF TLDs as a thermal neutron detector. It is likely that passive instruments will play a fundamental role also for monitoring the neutron fields generated by ultra-high intensity lasers, where the duration of a single pulse is of the order of hundreds femtoseconds. Arrays of tissue-equivalent proportional counters (TEPCs) of a millimetric/sub-millimetric physical size have been developed both for assessing the quality of therapeutic radiation beams and for estimating the RP quantities in low-intensity fields, which may limit the use of conventional microdosemeters. Very satisfactory results were obtained with GEM-based TEPCs and gas microstrip detectors (GMDs). Moreover, mini-TEPCs have been constructed and tested for measuring the quality of hadrontherapy beams (BNCT included). Silicon microdosemeters have also been demonstrated to be very promising for characterizing proton and ion beams for radiation therapy and for estimating the occurrence of single event effects in space applications.

  17. Dental CT: examination technique, radiation load and anatomy

    International Nuclear Information System (INIS)

    Lenglinger, F.X.; Muhr, T.

    1999-01-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [de

  18. Accreditation of physicist in radiotherapy-past, present and future

    International Nuclear Information System (INIS)

    Howlett, S.

    2010-01-01

    Full text: Accreditation of medical physicists for clinical radiotherapy practice was commenced by the ACPSEM in 1988 by a group of experienced physicists interested in setting a benchmark of international standard by which to assess practising radiotherapy physicists. It is a voluntary, peer based examination process and leads to the award of Accreditation in Radiotherapy Equipment Commissioning and Quality Assurance (ARECQA). The responsible body within the ACPSEM is the Radiation Oncology Accreditation Panel (ROAP) under the umbrella of the Professional Standards Board(PSB). Over 130 physicists in Australia and New Zealand have been awarded ARECQA and it has been recognised by the radiotherapy professions and government bodies as a desirable and sometimes required, standard of qualification. With the implementation of the Training, Education and Accreditation Program (TEAP) by ACPSEM in 2003, a new Accreditation in Radiation Oncology Medical Physics (AROMP) was established in 2005. ARECQA will cease taking applications from experienced physicists on December 31st 2012 and only the AROMP pathway will be available. An external review of TEAP funded by the Commonwealth Government Department of Health and Ageing (DoHA), which is not yet publicly released, will have implications for AROMP in the future. This talk will review the development and progress of accreditation in radiation oncology medical physics in Australia and New Zealand, its place in the delivery of quality patient care, the relationship to ACPSEM registration, the current situation and future directions. (author)

  19. Intensity Modulated Radiation Therapy. Development of the technique

    International Nuclear Information System (INIS)

    Rafailovici, L.; Alva, R.; Chiozza, J.; Donato, H.; Falomo, S.; Cardiello, C.; Furia, O.; Martinez, A.; Filomia, M.L.; Sansogne, R.; Arbiser, S.; Dosoretz, B.

    2008-01-01

    Full text: Introduction: Intensity Modulated Radiation Therapy (IMRT) is a result of advances in computer sciences that allowed the development of new technology related to planning and radiation therapy. IMRT was developed to homogenize the dose in the target volumes and decrease the dose in the surrounding healthy tissue. Using a software with high calculation capacity a simultaneous irradiation with different doses in a given volume is achieved. IMRT is based on internal planning. Material and methods: 628 patients were treated with IMRT in prostate lesions, head and neck, breast, thorax, abdomen and brain since August 2008. The software for IMRT is the XIO CMS and the accelerator used is a Varian Clinac 6 / 100. IMRT requires a first simulation, where immobilization systems are selected (mats, thermoplastic masks, among others) and the demarcation of the target structures, healthy tissue and dose prescription by a tattoo. Images of CT / MRI are merged when necessary. Once the system made the treatment optimization, this one is regulated by modulators. These are produced by numerical control machines from digital files produced by software. In a second modulation the planned irradiation is checked and tattoo is carried out according with this. We have a strict process of quality assurance to assess the viability of the plan before its implementation. We use the Map Check it possible to compare the dose on the central axis and the distribution in the whole plane regarding to that generated by the planning system. From 03/2008 the virtual simulation process was implemented integrating the described stages. Results and Conclusions: IMRT is a complex technique. The meticulous planning, implementation of process and quality control allows the use of this technique in a reliable and secure way. With IMRT we achieved a high level of dose conformation, less irradiation of healthy tissue, lower rates of complications and the dose escalation for some tumors. (authors) [es

  20. International conference on quality assurance and new techniques in radiation medicine. Book of extended synopses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    programmes that ensure the most effective use of available equipment and human resources. In diagnostic radiology, QA systems are being implemented to improve the determination of risk by calculating doses to organs of individual patients based on their specific anatomy and the details of the procedure that was performed. In medical radiation physics, recent developments in specific areas of QA of the physical and technical aspects in diagnostic and therapeutic applications and their links to comprehensive quality systems are of interest. In this context, contributions are expected on QA programmes and QC protocols in diagnostic radiology (e.g., mammography, CT, interventional, digital imaging, etc.), in nuclear medicine (e.g., dose assessment, radiopharmacy, PET/CT image fusion), and in radiation therapy (e.g., treatment planning and delivery, conformal therapy, stereotactic radiosurgery, etc.). Cross-cutting issues will be explored that have broad impact on quality such as, education, training and accreditation; telemedicine; data management and storage; etc. In addition, interdependent, cross-discipline issues are important. For example, special attention will be paid to the fidelity of tumour localization as delivered by diagnostic equipment since this is key input to the cancer treatment planning process and ongoing monitoring of treatment effects. In public health, DEXA bone densitometry is used widely in the diagnosis of osteoporosis as well as in measurements of body composition in nutrition evaluations. The technique is often used in longitudinal studies (repeated measures), for example to monitor the efficacy of a nutrition intervention. As DEXA is used in the monitoring of changes in body composition and changes in bone density, vulnerable population groups such as children and young adults are involved as well as postmenopausal women. As a result of bringing together experts in QA and health care professionals faced with practical decisions to be taken every day

  1. International conference on quality assurance and new techniques in radiation medicine. Book of extended synopses

    International Nuclear Information System (INIS)

    2006-01-01

    programmes that ensure the most effective use of available equipment and human resources. In diagnostic radiology, QA systems are being implemented to improve the determination of risk by calculating doses to organs of individual patients based on their specific anatomy and the details of the procedure that was performed. In medical radiation physics, recent developments in specific areas of QA of the physical and technical aspects in diagnostic and therapeutic applications and their links to comprehensive quality systems are of interest. In this context, contributions are expected on QA programmes and QC protocols in diagnostic radiology (e.g., mammography, CT, interventional, digital imaging, etc.), in nuclear medicine (e.g., dose assessment, radiopharmacy, PET/CT image fusion), and in radiation therapy (e.g., treatment planning and delivery, conformal therapy, stereotactic radiosurgery, etc.). Cross-cutting issues will be explored that have broad impact on quality such as, education, training and accreditation; telemedicine; data management and storage; etc. In addition, interdependent, cross-discipline issues are important. For example, special attention will be paid to the fidelity of tumour localization as delivered by diagnostic equipment since this is key input to the cancer treatment planning process and ongoing monitoring of treatment effects. In public health, DEXA bone densitometry is used widely in the diagnosis of osteoporosis as well as in measurements of body composition in nutrition evaluations. The technique is often used in longitudinal studies (repeated measures), for example to monitor the efficacy of a nutrition intervention. As DEXA is used in the monitoring of changes in body composition and changes in bone density, vulnerable population groups such as children and young adults are involved as well as postmenopausal women. As a result of bringing together experts in QA and health care professionals faced with practical decisions to be taken every day

  2. Radiation protection in newer medical imaging techniques: CT colonography

    International Nuclear Information System (INIS)

    2008-01-01

    Multislice/detector computed tomography (CT) scanning, applied to visualization of the colon in CT colonography (CTC), also known as virtual colonoscopy (VC), is a relatively new application of CT introduced in recent years. The possibility of its application in population screening techniques raises a number of questions. Effort is required to ensure that the benefit of this new practice will not pose an undue level of detriment to the individual in multiple examinations. For practitioners and regulators, it is evident that innovation has been driven by both the imaging industry and by an ever increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practice lag (inevitably) behind the industrial and clinical innovations being achieved. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill this growing vacuum, by bringing up to date and timely advice to bear on the problems involved. Under its statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for worldwide application of these standards, the IAEA has developed the Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS). The BSS was issued by the IAEA and co-sponsored by the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organisation (ILO), the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO) and the World Health Organization (WHO), and requires radiation protection of patients undergoing medical exposures through justification of the procedures involved and through optimization. The IAEA programme on radiation protection of patients encourages the reduction of patient doses without losing diagnostic benefits. To facilitate this

  3. Radiation protection in newer medical imaging techniques: PET/CT

    International Nuclear Information System (INIS)

    2008-01-01

    A major part of patient exposure now arises from practices that barely existed two decades ago, and the technological basis for their successful dissemination only began to flourish in the last decade or so. Hybrid imaging systems, such as the combination of computed tomography (CT) and positron emission tomography (PET), are an example of a technique that has only been introduced in the last decade. PET/CT has established a valuable place for itself in medical research and diagnosis. However, it is an application that can result in high patient and staff doses. For practitioners and regulators, it is evident that innovation has been driven both by the imaging industry and by an increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practices lag (inevitably) behind the industrial and clinical innovations. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill the growing vacuum, by bringing up to date and timely advice from experienced practitioners to bear on the problems involved. The advice in this report has been developed within the IAEA's statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for the worldwide application of these standards. The Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) were issued by the IAEA and co-sponsored by organizations including the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organisation (ILO), the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO) and the World Health Organization (WHO), and require the radiation protection of patients undergoing medical exposures through justification of the procedures involved and through

  4. Clinical laboratory accreditation in India.

    Science.gov (United States)

    Handoo, Anil; Sood, Swaroop Krishan

    2012-06-01

    Test results from clinical laboratories must ensure accuracy, as these are crucial in several areas of health care. It is necessary that the laboratory implements quality assurance to achieve this goal. The implementation of quality should be audited by independent bodies,referred to as accreditation bodies. Accreditation is a third-party attestation by an authoritative body, which certifies that the applicant laboratory meets quality requirements of accreditation body and has demonstrated its competence to carry out specific tasks. Although in most of the countries,accreditation is mandatory, in India it is voluntary. The quality requirements are described in standards developed by many accreditation organizations. The internationally acceptable standard for clinical laboratories is ISO15189, which is based on ISO/IEC standard 17025. The accreditation body in India is the National Accreditation Board for Testing and Calibration Laboratories, which has signed Mutual Recognition Agreement with the regional cooperation the Asia Pacific Laboratory Accreditation Cooperation and with the apex cooperation the International Laboratory Accreditation Cooperation.

  5. Radiation treatment planning techniques for lymphoma of the stomach

    International Nuclear Information System (INIS)

    Della Biancia, Cesar; Hunt, Margie; Furhang, Eli; Wu, Elisa; Yahalom, Joachim

    2005-01-01

    Purpose: Involved-field radiation therapy of the stomach is often used in the curative treatment of gastric lymphoma. Yet, the optimal technique to irradiate the stomach with minimal morbidity has not been well established. This study was designed to evaluate treatment planning alternatives for stomach irradiation, including intensity-modulated radiation therapy (IMRT), to determine which approach resulted in improved dose distribution and to identify patient-specific anatomic factors that might influence a treatment planning choice. Methods and Materials: Fifteen patients with lymphoma of the stomach (14 mucosa-associated lymphoid tissue lymphomas and 1 diffuse large B-cell lymphoma) were categorized into 3 types, depending on the geometric relationship between the planning target volume (PTV) and kidneys. AP/PA and 3D conformal radiation therapy (3DCRT) plans were generated for each patient. IMRT was planned for 4 patients with challenging geometric relationship between the PTV and the kidneys to determine whether it was advantageous to use IMRT. Results: For type I patients (no overlap between PTV and kidneys), there was essentially no benefit from using 3DCRT over AP/PA. However, for patients with PTVs in close proximity to the kidneys (type II) or with high degree of overlap (type III), the 4-field 3DCRT plans were superior, reducing the kidney V 15Gy by approximately 90% for type II and 50% for type III patients. For type III, the use of a 3DCRT plan rather than an AP/PA plan decreased the V 15Gy by approximately 65% for the right kidney and 45% for the left kidney. In the selected cases, IMRT led to a further decrease in left kidney dose as well as in mean liver dose. Conclusions: The geometric relationship between the target and kidneys has a significant impact on the selection of the optimum beam arrangement. Using 4-field 3DCRT markedly decreases the kidney dose. The addition of IMRT led to further incremental improvements in the left kidney and liver

  6. 76 FR 52548 - National Veterinary Accreditation Program; Currently Accredited Veterinarians Performing...

    Science.gov (United States)

    2011-08-23

    .... APHIS-2006-0093] RIN 0579-AC04 National Veterinary Accreditation Program; Currently Accredited... accredited in the National Veterinary Accreditation Program (NVAP) may continue to perform accredited duties..., 2011. FOR FURTHER INFORMATION CONTACT: Dr. Todd Behre, National Veterinary Accreditation Program, VS...

  7. Development of food preservation and processing techniques by radiation

    International Nuclear Information System (INIS)

    Byun, Myung Woo; Yook, Hong Sun; Lee, Ju Woon and others

    1999-03-01

    Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute toxicity, four-week oral toxicity, rat hepato carcinogenesis and the anti oxidative defense system, were not affected by gamma irradiation. To pre-establish an alternative technique to the toxic fumigant, methyl bromide, which is the current quarantine measure of agricultural products for export and import, some selected agricultural products, such as chestnuts, acorns, red beans and mung beans, were subjected to a preliminary study to confirm the comparative effects of gamma irradiation and MBr fumigant on their disinfestation and quality, thereby preparing the basic data for the practical approach.Current fumigation(MBr) was perfect in its disinfecting capability, but it caused detrimental effects on the physical quality of agricultural produce. However, irradiation doses suitable for controlling pests did not induce any significant changes in the quality of the products. (author)

  8. Tomotherapeutic stereotactic body radiation therapy: Techniques and comparison between modalities

    International Nuclear Information System (INIS)

    Fuss, Martin; Chengyu Shi; Papanikolaou, Niko

    2006-01-01

    Presentation and comparison of tomotherapeutic intensity-modulated techniques for planning and delivery of stereotactic body radiation therapy. Serial tomotherapeutic SBRT has been planned and delivered at our institution since 8/2001. Since 12/2005, 12 patients have been treated using a helical tomotherapy unit. For these 12 patients both helical and serial tomotherapy plans were computed and clinically approved. Techniques and considerations of tomotherapy SBRT planning, associated image-guidance, and delivery are presented. The respective treatment plans were compared based on dosimetric parameters as well as time to develop a treatment plan and delivery times. Also the associated quality of megavoltage CT (MVCT) image-guidance inherent to the helical tomotherapy unit was assessed. Tumor volumes averaged 9.3, 9.8, and 58.7 cm 3 for liver, lung, and spinal targets. Helical and serial tomotherapy plans showed comparable plan quality with respect to maximum and average doses to the gross tumor and planning target volumes. Time to develop helical tomotherapy plans averaged 3.5 h while serial tomotherapy planning consistently required less than one hour. Treatment delivery was also slower using helical tomotherapy, with differences of less than 10 min between modalities. MVCT image-guidance proved satisfactory for bony and lung targets, but failed to depict liver lesions, owing to poor soft-tissue contrast. SBRT planning and delivery is clinically feasible using either tomotherapeutic modality. While treatment planning time was consistently shorter and more readily accomplished in a standardized approach using the serial tomotherapy modality, actual plan quality and treatment delivery times are grossly comparable between the modalities. MVCT volumetric image-guidance, was observed to be valuable for thoracic and spinal target volumes, whereas it proved challenging for liver targets

  9. Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques

    DEFF Research Database (Denmark)

    Hansen, Anders T; Lukacova, Slavka; Lassen-Ramshad, Yasmin A.

    2015-01-01

    When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar...... patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanar volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique...... substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore...

  10. Development of food preservation and processing techniques by radiation

    International Nuclear Information System (INIS)

    Byun, Myung Woo; Yook, Hong Sun; Lee, Ju Woon and others

    2000-03-01

    Development of food preservation and processing techniques by radiation was performed. Gamm irradiation at 5 kGy completely eliminated pathogenic bacteria in pork and chicken meats. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Pork loin ham with desirable color was also developed without using of sodium nitrite that is known as a carcinogen. Safety tests of gamma-irradiated meats in areas such as genotoxicity, acute toxicity, four-week oral toxicity, rat hepatocarcinogenesis and the antioxidative defense system, were not affected by gamma irradiation. Gamma irradiation at about 1 kGy completely eliminated the parasites in foods and drinking water. In the study of quarantine treatment of apple and pear for export by gamma irradiation, current fumigation(MBr) was perfect in its disinfesting capability, but it caused detrimental effects on the physical quality of apple and pear. However, irradiation doses at 1-3 kGy was suitable for controlling pests and did not induce any significant changes in the quality of the products. The result of the survey to assess the public understanding indicated that the irradiated food had somewhat negative impression to general public. Therefore, it is necessary to establish a public education and information program by using mass communication and by constructing communication system to obtain the enhanced impression from the general public

  11. Development of food preservation and processing techniques by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Myung Woo; Yook, Hong Sun; Lee, Ju Woon and others

    2000-03-01

    Development of food preservation and processing techniques by radiation was performed. Gamm irradiation at 5 kGy completely eliminated pathogenic bacteria in pork and chicken meats. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Pork loin ham with desirable color was also developed without using of sodium nitrite that is known as a carcinogen. Safety tests of gamma-irradiated meats in areas such as genotoxicity, acute toxicity, four-week oral toxicity, rat hepatocarcinogenesis and the antioxidative defense system, were not affected by gamma irradiation. Gamma irradiation at about 1 kGy completely eliminated the parasites in foods and drinking water. In the study of quarantine treatment of apple and pear for export by gamma irradiation, current fumigation(MBr) was perfect in its disinfesting capability, but it caused detrimental effects on the physical quality of apple and pear. However, irradiation doses at 1-3 kGy was suitable for controlling pests and did not induce any significant changes in the quality of the products. The result of the survey to assess the public understanding indicated that the irradiated food had somewhat negative impression to general public. Therefore, it is necessary to establish a public education and information program by using mass communication and by constructing communication system to obtain the enhanced impression from the general public.

  12. A study on immobilized ethanol yeast cells by radiation technique

    International Nuclear Information System (INIS)

    Li Zhengkui; Zhang Bosen

    1994-01-01

    Hydrophilic monomer 2-hydroxyethyl acrylate (HEA) and a series of polyethylene glycol dimethacrylate monomers were copolymerized by radiation technique at low temperature (-78 degree C) and hydrophilic hydrogels were obtained. The immobilization of yeast cells with these copolymer carriers led to a higher ethanol productivity than free cells. Of all copolymer carriers, the ethanol yield with poly (HEA-14 G) was the highest, about 2.45 times as high as that of free yeast cells. In addition, the ethanol productivity of 12 batch repeated reactions with poly (HEA-14G) carrier was all higher than that of free yeast cells. The ethanol productivity of immobilized yeast cells was dependent on the proportion of hydrophilic monomer to other monomers in copolymer systems, the chain length of the bifunctional monomer, the degree of hydration of copolymer carriers, the structure of copolymer carriers and porosity in the internal structure of carriers. The ethanol yield of immobilized cells depended on swelling ability and porosity of copolymer carriers

  13. Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy

    International Nuclear Information System (INIS)

    Jang, Joon Yung; Park, Soo Yun; Kim, Jong Sik; Choi, Byeong Gi; Song, Gi Won

    2011-01-01

    Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  14. Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joon Yung; Park, Soo Yun; Kim, Jong Sik; Choi, Byeong Gi; Song, Gi Won [Dept. of Radiation Oncology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-09-15

    Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  15. Study on production of useful metabolites by development of advanced cell culture techniques using radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Byung Yeoup; Kim, Jinhong; Lee, Seung Sik; Bai, Hyounwoo; An, Byung Chull; Lee, Eun Mi; Lee, Jae Taek; Kim, Mi Ja

    2010-12-15

    The purpose of this project is improvement of investigation, materialization and evaluation techniques on effectiveness for functional natural compounds throughout development of tissue/cell culture techniques for mass production of useful metabolites using radiation. Research scope includes Development of a technique for radiation tissue and cell culture, Database construction for radiation response in plants and radiation effects, Construction of general-purpose national based techniques of cell culture technique using radiation. Main results are as follow: Isolation and identification of radiation induced basI gene; Determination of stresses sensitivities by transformating basI gene into arabidopsis; Isolation and identification of radiation induced chaperon proteins (PaAhpC and yPrxII) from Pseudomonas and yeast, and structural and functional analysis of the proteins; Determination of oxidative and heat resistance by transformating PaAhpC; Isolation and identification of maysin and its derivatives from centipedgrass; Investigation of enhancement technique for improving maysin and its derivatives production using radiation; Investigation of removing undesirable color in maysin and its derivatives using radiation; Determination of the effect of radiation on physiological functions of centipedgrass extracts; Identification of H{sub 2}O{sub 2} removing enzyme in radiation irradiated plant (Spinach); Determination of the effects of centipedgrass extracts on anti-obesity and anti-cancer activities.

  16. Study on production of useful metabolites by development of advanced cell culture techniques using radiation

    International Nuclear Information System (INIS)

    Chung, Byung Yeoup; Kim, Jinhong; Lee, Seung Sik; Bai, Hyounwoo; An, Byung Chull; Lee, Eun Mi; Lee, Jae Taek; Kim, Mi Ja

    2010-12-01

    The purpose of this project is improvement of investigation, materialization and evaluation techniques on effectiveness for functional natural compounds throughout development of tissue/cell culture techniques for mass production of useful metabolites using radiation. Research scope includes Development of a technique for radiation tissue and cell culture, Database construction for radiation response in plants and radiation effects, Construction of general-purpose national based techniques of cell culture technique using radiation. Main results are as follow: Isolation and identification of radiation induced basI gene; Determination of stresses sensitivities by transformating basI gene into arabidopsis; Isolation and identification of radiation induced chaperon proteins (PaAhpC and yPrxII) from Pseudomonas and yeast, and structural and functional analysis of the proteins; Determination of oxidative and heat resistance by transformating PaAhpC; Isolation and identification of maysin and its derivatives from centipedgrass; Investigation of enhancement technique for improving maysin and its derivatives production using radiation; Investigation of removing undesirable color in maysin and its derivatives using radiation; Determination of the effect of radiation on physiological functions of centipedgrass extracts; Identification of H 2 O 2 removing enzyme in radiation irradiated plant (Spinach); Determination of the effects of centipedgrass extracts on anti-obesity and anti-cancer activities

  17. Accreditation: a cultural control strategy.

    Science.gov (United States)

    Paccioni, André; Sicotte, Claude; Champagne, François

    2008-01-01

    The purpose of this paper is to describe and understand the effects of the accreditation process on organizational control and quality management practices in two Quebec primary-care health organizations. A multiple-case longitudinal study was conducted taking a mixed qualitative/quantitative approach. An analytical model was developed of the effects of the accreditation process on the type of organizational control exercised and the quality management practices implemented. The data were collected through group interviews, semi-directed interviews of key informers, non-participant observations, a review of the literature, and structured questionnaires distributed to all the employees working in both institutions. The accreditation process has fostered the implementation of consultation mechanisms in self-assessment teams. Improving assessments of client satisfaction was identified as a prime objective but, in terms of the values promoted in organizations, accreditation has little effect on the perceptions of employees not directly involved in the process. As long as not all staff members have integrated the basis for accreditation and its outcomes, the accreditation process appears to remain an external, bureaucratic control instrument. This study provides a theoretical model for understanding organizational changes brought about by accreditation of primary services. Through self-assessment of professional values and standards, accreditation may foster better quality management practices.

  18. Aligning Assessments for COSMA Accreditation

    Science.gov (United States)

    Laird, Curt; Johnson, Dennis A.; Alderman, Heather

    2015-01-01

    Many higher education sport management programs are currently in the process of seeking accreditation from the Commission on Sport Management Accreditation (COSMA). This article provides a best-practice method for aligning student learning outcomes with a sport management program's mission and goals. Formative and summative assessment procedures…

  19. University Accreditation using Data Warehouse

    Science.gov (United States)

    Sinaga, A. S.; Girsang, A. S.

    2017-01-01

    The accreditation aims assuring the quality the quality of the institution education. The institution needs the comprehensive documents for giving the information accurately before reviewed by assessor. Therefore, academic documents should be stored effectively to ease fulfilling the requirement of accreditation. However, the data are generally derived from various sources, various types, not structured and dispersed. This paper proposes designing a data warehouse to integrate all various data to prepare a good academic document for accreditation in a university. The data warehouse is built using nine steps that was introduced by Kimball. This method is applied to produce a data warehouse based on the accreditation assessment focusing in academic part. The data warehouse shows that it can analyse the data to prepare the accreditation assessment documents.

  20. IADC's well control accreditation program

    International Nuclear Information System (INIS)

    Kropla, S.M.

    1997-01-01

    WellCAP is a well control accreditation program devised and implemented by the International Association of Drilling Contractors (IADC). It is a worldwide comprehensive system that defines a well control training curriculum, establishes minimum standards and recommends guidelines for course structure. The program began in mid-1993 and is viewed as a means for training institutions to demonstrate industry recognition to customers, contractors and local governments. Schools can apply to have their courses accredited. The accreditation system is administered by a review panel. The application process requires that the school perform a detailed review of its curriculum and operations and bring them in line with the WellCAP curriculum and accreditation criteria. Currently, more than 75 schools around the world have requested application materials for WellCAP. To date fifteen schools have been fully accredited

  1. Disposal regulations and techniques applicable to devices using ionising radiation

    International Nuclear Information System (INIS)

    Vidal, J.P.

    1998-01-01

    L'office de Protection contre les rayonnement ionisants, being a government body under the supervision of Ministry of Health and Labour, among other different missions controls the compliance of radiation protection laws with the aim to guarantee the safe operation of equipment using ionising radiation sources. These regulations concerning competence of personnel, especially in the field of medicine or application of ionising radiation on humans, are restricted only to medical doctors (or dentists in their domain) by technical constraints dealing with design of equipment and its exploitation. At the same time regulations define conditions of permanent control in order to verify compliance of radiation protection laws

  2. Preparation of functionalized carbon nanotubes using radiation technique

    International Nuclear Information System (INIS)

    Chen Shimou; Wu Guozhong; Huang Shirong; Zhu Guanglai

    2006-01-01

    Carbon nanotubes (CNTs) have attracted great interest because of their unique structural, electronic, mechanical, and optical properties. However, the studies and applications of CNTs are hindered by processing and manipulation difficulties owing to their insolubility or poor dispersion in common solvents and polymeric matrixes. To facilitate their applications, many approaches were employed to functionalize CNTs with functional groups, either noncovalently or covalently. In our study, radiation technique was utilized to produce functionalized CNTs. In a typical experiment, multiwalled carbon nanotubes (MWNTs) were irradiated in potassium persulfate aqueous solution. Persulfnic group can react with hydrated electrons to produce sulfuric acid radicals, which can attack the c=c on the surface of tubes to form sulfonated MWNTs. On the other hand, grafting polymer (instead of low-molecular-weight compound) onto CNTs by an appropriate method is a possible strategy for preparing the nanotubes with little damage in structure and high solubility in solvent. A facile strategy to prepare water soluble MWNTs in large scale by two steps of gamma irradiation has been developed at SINAP. The first step is to irradiate MWNTs in ethanol. The radiolysis of ethanol produced many active species such as . CH 2 CH 2 OH, CH 3 . CHCH 2 OH, which react with C=C of MWNTs and attach onto the surface of MWNTs. Then, poly(acrylic acid) was covalently grafted to the surface of MWNTs by irradiating the samples in the presence of acrylic acid. The PAA-grafted MWNTs have good solubility in water and other polar solvents. This two-step grafting approach may also be of help for introducing other functional polymer chains onto MWNTs. (authors)

  3. Aerial radiation survey techniques for efficient characterization of large areas

    International Nuclear Information System (INIS)

    Sydelko, T.; Riedhauser, S.

    2006-01-01

    Full text: Accidental or intentional releases of radioactive isotopes over potentially very large surface areas can pose serious health risks to humans and ecological receptors. Timely and appropriate responses to these releases depend upon rapid and accurate characterization of impacted areas. These characterization efforts can be adversely impacted by heavy vegetation, rugged terrain, urban environments, and the presence of unknown levels of radioactivity. Aerial survey techniques have proven highly successful in measuring gamma emissions from radiological contaminates of concern quickly, efficiently, and safely. Examples of accidental releases include the unintentional distribution of uranium mining ores during transportation, the loss of uranium processing and waste materials, unintentional nuclear power plant emissions into the atmosphere, and the distribution of isotopes during major flooding events such as the one recently occurring in New Orleans. Intentional releases have occurred during the use of deleted uranium ammunition test firing and war time use by military organizations. The threat of radiological dispersion device (dirty bomb) use by terrorists is currently a major concern of many major cities worldwide. The U.S. Department of Energy, in cooperation with its Remote Sensing Laboratory and Argonne National Laboratory, has developed a sophisticated aerial measurement system for identifying the locations, types, and quantities of gamma emitting radionuclides over extremely large areas. Helicopter mounted Nal detectors are flown at low altitude and constant speed along parallel paths measuring the full spectrum of gamma activity. Analytical procedures are capable of distinguishing between radiological contamination and changes in natural background emissions. Mapped and tabular results of these accurate, timely and cost effective aerial gamma radiation surveys can be used to assist with emergency response actions, if necessary, and to focus more

  4. Training and accreditation for radon professionals in Sweden

    International Nuclear Information System (INIS)

    Mjoenes, L.; Soederman, A.-L.

    2004-01-01

    Radon training courses and seminars on radon have been arranged in Sweden since the early 1980s. A commercial educational company initiated the first regular training courses in 1987. Up to 1990 about 400 persons had attended courses in radon measurement and radon mitigation methods. In 1991 the training programme was taken over by the Swedish Radiation Protection Authority, SSI. Today SSI's Radon Training Programme comprises three different two-day courses, a Basic Radon Course and two continuation courses: Radon Measurements and Radon in Water. Until 2003 SSI also arranged courses about Radon Remedial Measures and Radon Investigation and Risk Map Production. The courses are arranged twice a year. Altogether, about 750 municipal environmental health officers and technicians from private companies have been educated in the SSI training programme between 1991 and 2003. The continuation courses are completed with an examination, consisting of a theoretical test. The names of the persons who pass are being published in a list that is found on the SSI web site. Since no certification system is currently in place for radon professionals in Sweden, this list helps people who need to get in contact with radon counsellors to find one in their area and is used by authorities as well as private house-owners. Since 1991 it has been possible to obtain accreditation for measurements of indoor radon in Sweden and since 1997, also for measurements of radon in water. Although accreditation is voluntary in Sweden, accredited laboratories perform most measurements, both for indoor air and water. Passing the examination in the SSI training courses is a condition for accreditation. The Swedish Board for Accreditation and Conformity Assessment, SWEDAC, is in charge of the accreditation. So far, three major companies have obtained accreditation for measurement of indoor radon and four have been accredited for measurements of radon in water

  5. Study on production of useful metabolites by development of advanced cell culture techniques using radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Byung Yeoup; Lee, Seung Sik; Bai, Hyounwoo; Singh, Sudhir; Lee, Eun Mi; Hong, Sung Hyun; Park, Chul Hong; Srilatha, B.; Kim, Mi Ja; Lee, Ohchul

    2012-01-15

    The purpose of this project is improvement of investigation, materialization and evaluation techniques on effectiveness for functional natural compounds throughout development of tissue/cell culture techniques for mass production of useful metabolites using radiation. Research scope includes Development of a technique for radiation tissue and cell culture, Database construction for radiation response in plants and radiation effects, Construction of general-purpose national based techniques of cell culture technique using radiation. Main results are as follow: Development of a technique for radiation tissue and cell culture for Erigeron breviscapus (Vant.) Hand. Mazz.; Identification and functional analysis of AtTDX (chaperone and peroxidase activities); Functional analysis of radiation(gamma ray, electron beam, and proton beam) induced chaperon protein activities (AtTDX); Determine the action mechanism of yPrx2; Development of transgenic plant with bas I gene from Arabidopsis; Development of transgenic plant with EoP gene from centipedegrass; Identification of radiation induced multi functional compounds from Aloe; Determination of the effects of radiation on removing undesirable color and physiological activities (Schizandra chinensis baillon, centipedegrass); Determine the action mechanism of transgenic plant with 2-Cys Prx for heat stress resistance; Determination of the effects of centipedegrass extracts on anti-cancer activities; Functional analysis of centipedegrass extracts (anti-virus effects)

  6. Hypofractionation does not increase radiation pneumonitis risk with modern conformal radiation delivery techniques

    DEFF Research Database (Denmark)

    Vogelius, Ivan R; Westerly, David C; Cannon, George M

    2010-01-01

    To study the interaction between radiation dose distribution and hypofractionated radiotherapy with respect to the risk of radiation pneumonitis (RP) estimated from normal tissue complication probability (NTCP) models.......To study the interaction between radiation dose distribution and hypofractionated radiotherapy with respect to the risk of radiation pneumonitis (RP) estimated from normal tissue complication probability (NTCP) models....

  7. Radiation protection of patients in X-ray diagnostic techniques

    International Nuclear Information System (INIS)

    Gerhardt, P.

    1975-01-01

    The author states as a result that the care taken by the physician and the technical assistant is the most important factor in reducing the radiation exposure of patients. A fair relation between efficiency and possible unnecessary exposure is provided by careful and conscientious work which has to be based on sound knowledge of the effects of ionizing radiation on the organism and of the possibilities of reducing the doses responsible for these effects. (orig./AK) [de

  8. Commission for the Accreditation of Birth Centers

    Science.gov (United States)

    ... Learning Login: Commissioners Birth Centers CABC Learning Place Home Accredited Birth Centers Find CABC Accredited Birth Centers What does ... In the Pursuit of Excellence You are here: Home In the ... for the Accreditation of Birth Centers (CABC) provides support, education, and accreditation to ...

  9. Standards of Quality: Accreditation Guidelines Redesigned

    Science.gov (United States)

    Forsythe, Hazel; Andrews, Frances; Stanley, M. Sue; Anderson, Carol L.

    2011-01-01

    To ensure optimal standards for AAFCS program accreditation, the Council for Accreditation (CFA) conducted a review and revision of the "2001 AAFCS Standards for Accreditation." The CFA took a three-pronged approach including (a) a review of academic accreditations that had relationships to the FCS disciplines, (b) concept, content, and process…

  10. Securing safe and informative thoracic CT examinations—Progress of radiation dose reduction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Takeshi, E-mail: tkubo@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan); Ohno, Yoshiharu [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan); Seo, Joon Beom [Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505 (Korea, Republic of); Yamashiro, Tsuneo [Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, 207 Uehara, Nishinara, Okinawa 903-0215 (Japan); Kalender, Willi A. [Institute of Medical Physics, Friedrich-Alexander-University Erlangen-Nürnberg, Henkestr. 91, 91052 Erlangen (Germany); Lee, Chang Hyun [Department of Radiology, Seoul National University Hospital, 28 Yeongeon-dong, Jongno-gu, Seoul (Korea, Republic of); Lynch, David A. [Department of Radiology, National Jewish Health, 1400 Jackson St, A330 Denver, Colorado 80206 (United States); Kauczor, Hans-Ulrich [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Hatabu, Hiroto, E-mail: hhatabu@partners.org [Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women' s Hospital, 75 Francis Street, Boston, MA 02115 (United States)

    2017-01-15

    Highlights: • Various techniques have led to substantial radiation dose reduction of chest CT. • Automatic modulation of tube current has been shown to reduce radiation dose. • Iterative reconstruction makes significant radiation dose reduction possible. • Processing time is a limitation for full iterative reconstruction, currently. • Validation of diagnostic accuracy is desirable for routine use of low dose protocols. - Abstract: The increase in the radiation exposure from CT examinations prompted the investigation on the various dose-reduction techniques. Significant dose reduction has been achieved and the level of radiation exposure of thoracic CT is expected to reach the level equivalent to several chest X-ray examinations. With more scanners with advanced dose reduction capability deployed, knowledge on the radiation dose reduction methods has become essential to clinical practice as well as academic research. This article reviews the history of dose reduction techniques, ongoing changes brought by newer technologies and areas of further investigation.

  11. Vaccines for veterinary, made with the help of radiative technique

    International Nuclear Information System (INIS)

    Bulkhanov, R.U.; Butaev, M.K.; Mirsaev, B.Sh.; Ryasnaynskiy, I.V.; Yuldashev, R.Yu.

    2004-01-01

    Full text: In applied radiology scientists usually use stimulating, mutagenic and inactivating effects of gamma-radiation. In this report there are the results of gamma-radiation inactivating effect for radiovaccine making biotechnology development for veterinary. Inactivation with hamma-irradiation gives us opportunity to make highly immunogenic vaccines, which cause minimum damage of antigenic contaminants structure. With the help of radiative biotechnology we can produce highly effective monoassociated and polyvalented radiovaccines against the most wide-spread infections disease in agricultural animals, young animals in particular (calves, lambs, sucking-pigs). These diseases include such infection diseases as colibacterioses, salmonellosis, pasterellosis, which cause much economic damage to stockbreeding i.e. loss of cattle, slow growth of young animal, lack of offsprings, decrease of reproduction properties. Monovaccines are used for these disease prophylaxis as well as associated and polyvalented vaccines. Taking into consideration the necessity of vaccine improvement and great amount of associated vaccines, one of the main problems of veterinary is the development of vaccines of new generation, which can induce immunity against several diseases in agricultural animals. That is why, radiative biotechnology of radiovaccines creation was developed and is used in radiative laboratory of Uzbek Scientific Veterinary Institute (Bulkhanov R.U., 1999, 2001), A ssociated radiovaccine against colibacteriosis, salmonellosis of calves, kids , 'Associated radiovaccine against colibacteriosis and salmonellosis of calves', 'Polyvalented radiovaccine against pasterellosis, salmonellosis and colibacteriosis in agricultural animals' were developed with the help of radiative biotechnology and are successfully used in veterinary practice. The advantage of these radiovaccines is that they produce one year immunity and you need twice less dosage and revaccinations. More than

  12. 75 FR 59605 - National Veterinary Accreditation Program; Currently Accredited Veterinarians Performing...

    Science.gov (United States)

    2010-09-28

    .... APHIS-2006-0093] RIN 0579-AC04 National Veterinary Accreditation Program; Currently Accredited... Veterinary Accreditation Program (NVAP) may continue to perform accredited duties and to elect to continue to..., National Veterinary Accreditation Program, VS, APHIS, 4700 River Road Unit 200, Riverdale, MD 20737; (301...

  13. [Accreditation of Independent Ethics Committees].

    Science.gov (United States)

    Ramiro Avilés, Miguel A

    According to Law 14/2007 and Royal Decree 1090/2015, biomedical research must be assessed by an Research Ethics Committee (REC), which must be accredited as an Research ethics committee for clinical trials involving medicinal products (RECm) if the opinion is issued for a clinical trial involving medicinal products or clinical research with medical devices. The aim of this study is to ascertain how IEC and IECm accreditation is regulated. National and regional legislation governing biomedical research was analysed. No clearly-defined IEC or IECm accreditation procedures exist in the national or regional legislation. Independent Ethics Committees are vital for the development of basic or clinical biomedical research, and they must be accredited by an external body in order to safeguard their independence, multidisciplinary composition and review procedures. Copyright © 2016 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. List of Accredited Claims Agents

    Data.gov (United States)

    Department of Veterans Affairs — VA accreditation is for the sole purpose of providing representation services to claimants before VA and does not imply that a representative is qualified to provide...

  15. Accreditation, the reward for quality

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    Arkansas Power and Light Co. (AP and L) includes safety along with efficiency in the ''bottom line'' of a quality training program designed to improve performance at its nuclear units. The program keeps operators aware of design and refueling as well as regulatory changes. The Institute of Nuclear Power Operations (INPO) accredited the utility's operator training program in 1984. The article cites examples of the training program, and gives an overview of the INPO team's analysis that led to accreditation

  16. Recent developments and trends in radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Maushart, R.

    1993-01-01

    Measuring instruments used in radiation protection have undergone dramatic changes over the past decade. But also the attitude of users vis-a-vis this equipment is changing. This is reflected in changes in equipment concepts, the trend being towards 'considerate equipment' which does not absorb the user's attention, but reserves it for the real proposes of radiation protection. Just measuring is no longer enough. Measured data acquisition and evaluation must be integrated more closely, and more specifically, into an overall process of optimized in-plant radiation protection. A key role in this scheme is played by the application-oriented user interface, while measurement and testing routines become more and more automated. The technology now available for storing programs and data, interconnecting and displaying them in many ways, offers almost unlimited possibilities

  17. Monolithic active pixel radiation detector with shielding techniques

    Energy Technology Data Exchange (ETDEWEB)

    Deptuch, Grzegorz W.

    2018-03-20

    A monolithic active pixel radiation detector including a method of fabricating thereof. The disclosed radiation detector can include a substrate comprising a silicon layer upon which electronics are configured. A plurality of channels can be formed on the silicon layer, wherein the plurality of channels are connected to sources of signals located in a bulk part of the substrate, and wherein the signals flow through electrically conducting vias established in an isolation oxide on the substrate. One or more nested wells can be configured from the substrate, wherein the nested wells assist in collecting charge carriers released in interaction with radiation and wherein the nested wells further separate the electronics from the sensing portion of the detector substrate. The detector can also be configured according to a thick SOA method of fabrication.

  18. Advances in SSTR techniques for dosimetry and radiation damage measurements

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Ruddy, F.H.

    1979-01-01

    Solid state track recorders (SSTR) have been applied in the diverse nuclear reactor research. Two recent advances are described which possess outstanding relevance for reactor research, namely the evolvement of SSTR radiation damage monitors and the development of CR-39, a new plastic SSTR of extremely high sensitivity. Results from high fluence irradiations of natural quartz crystal SSTR are used to illustrate the concept of the SSTR radiation damage monitor. Response characteristics of CR-39 are presented with emphasis on the remarkable proton sensitivity of this new SSTR

  19. Technique of radiation polymerization in fine art conservation: a potentially new method of restoration and preservation

    International Nuclear Information System (INIS)

    Garnett, J.L.; Major, G.

    1982-01-01

    The technique of using radiation polymerization for the restoration and preservation of art treasures is considered. The processes discussed include both radiation grafting and rapid cure procedures, particularly reactions initiated by uv and eb. Representative examples where the technique has already been used are treated including typical applications with paintings, tapestries, leather and archival repair. The structure of the monomers and oligomers used in both grafting and rapid cure systems is outlined. The experimental conditions where grafting may occur during radiation rapid cure processing are discussed. Possible future developments of the technique are outlined. 1 figure, 8 tables

  20. Chitosan-containing hydrogel wound dressings prepared by radiation technique

    International Nuclear Information System (INIS)

    Mozalewska, Wiktoria; Czechowska-Biskup, Renata; Olejnik, Alicja K.; Wach, Radoslaw A.; Ulański, Piotr; Rosiak, Janusz M.

    2017-01-01

    The aim of the study was to develop an antimicrobial hydrogel wound dressing by means of radiation-initiated crosslinking of hydrophilic polymers, i.e. by well-established technology comprising gel manufacturing and its sterilization in one process. The approach included admixture of chitosan of relatively low molecular weight dissolved in lactic acid (LA) into the initial regular components of the conventional hydrogel dressing based on poly(N-vinyl pyrrolidone) (PVP) and agar. Molecular weight of chitosan was regulated by radiation-initiated degradation in the range of 39–132 kg mol −1 . Optimum total concentration of LA in the resultant hydrogel dressing was evaluated as 0.05 mol dm −3 , that is ca. 0.5%. Presence of LA in the system influenced essential radiation and technological parameters of hydrogel manufacturing. The setting temperature of the pre-hydrogel mixture, resulting from agar ability to congeal, was reduced with LA concentration, yet remained significantly above the room temperature. 0.5% of chitosan was effectively dissolved in aqueous solution of lactic acid due to its pH (lower than 5.5). Radiation parameters of PVP crosslinking in the presence of LA, as determined with generalized Charlesby–Pinner equation, were reflected in slight reduction of the maximum gel fraction and increase in gelation dose and in the factor comparing yields of scission to crosslinking. Nevertheless, essentially physical characteristics of the hydrogel was not affected, except for somewhat increased water uptake capacity, what in turn improves functionality of the dressing as extensive exudate for the wound can be efficiently absorbed. Preliminary microbiological studies showed antimicrobial character of the chitosan-containing hydrogel towards Gram-positive bacterial strain. - Highlights: • Radiation synthesis of bioactive hydrogel wound dressing based on PVP. • Sol-gel analysis, radiation yield of crosslinking and degradation, gel fraction.

  1. Teaching material for radiation education using radiography technique

    International Nuclear Information System (INIS)

    Kamata, Masahiro; Katagiri, Sachiko; Fujine, Shigenori; Yoneda, Kenji

    1999-01-01

    In order to develop a teaching material that helps learners to understand the interaction between substances and radiation, a periodic table was prepared on which pure pieces of nearly thirty element were fixed and radiographic images of the periodic table were taken using X ray and neutron beam under several conditions. Obtained images are so clear that they can be expected to be very helpful in intuitive understanding on the magnitude of the interaction. (author)

  2. Radiation protection optimisation techniques and their application in industry

    Energy Technology Data Exchange (ETDEWEB)

    Lefaure, C

    1997-12-31

    Since the International Commission on Radiation Protection (ICRP) recommendation 60, the optimisation principle appears to be the core of the radiation protection system. In practice applying it, means implementing an approach both predictive and evolutionary - that relies essentially on a prudent and responsible state of mind. the formal expression of this process, called optimization procedure, implies and indispensable tool for its implementation: the system of monetary values for the unit of collective dose. During the last few years, feed ALARA principle means that a global work management approach must be adopted, considering together all factors contributing to radiation dose. In the nuclear field, the ALARA approach appears to be more successful when implemented in the framework of a managerial approach through structure ALARA programmes. Outside the nuclear industry it is necessary to clearly define priorities through generic optimisation studies and ALARA audits. At the international level much efforts remain to be done to expand efficiently the ALARA process to internal exposure as well as to public exposure. (author) 2 graphs, 5 figs., 3 tabs.

  3. Industrial radiation and radioisotope gauging techniques and applications

    International Nuclear Information System (INIS)

    Gardner, R.P.

    1997-01-01

    The radiation and radioisotope gauging industry in the United States has primarily followed a path of development solely by the private sector. It has remained highly proprietary in nature, which is opposite to the path taken by many other countries. In other countries radiation gauge development has been controlled in large part by government-sponsored research and development, which has spawned many more publications in the open literature. Historically, some of the leaders have been Great Britain, Poland, France, Russia, and Australia. This has possibly led to the misconception that the development of this technology is being dominated by countries outside the United States. This is not a healthy situation-it would be good to see our industry begin to publish more in the open literature and to sponsor more research at universities. In efforts to promote more open-literature publication, the American Nuclear Society (ANS) sponsored a topical meeting on Industrial Radiation and Radioisotope Measurement Applications (IRRMA) in 1988 that was held again in 1992

  4. Radiation protection optimisation techniques and their application in industry

    International Nuclear Information System (INIS)

    Lefaure, C.

    1996-01-01

    Since the International Commission on Radiation Protection (ICRP) recommendation 60, the optimisation principle appears to be the core of the radiation protection system. In practice applying it, means implementing an approach both predictive and evolutionary - that relies essentially on a prudent and responsible state of mind. the formal expression of this process, called optimization procedure, implies and indispensable tool for its implementation: the system of monetary values for the unit of collective dose. During the last few years, feed ALARA principle means that a global work management approach must be adopted, considering together all factors contributing to radiation dose. In the nuclear field, the ALARA approach appears to be more successful when implemented in the framework of a managerial approach through structure ALARA programmes. Outside the nuclear industry it is necessary to clearly define priorities through generic optimisation studies and ALARA audits. At the international level much efforts remain to be done to expand efficiently the ALARA process to internal exposure as well as to public exposure. (author)

  5. Radiation protection optimisation techniques and their application in industry

    Energy Technology Data Exchange (ETDEWEB)

    Lefaure, C

    1996-12-31

    Since the International Commission on Radiation Protection (ICRP) recommendation 60, the optimisation principle appears to be the core of the radiation protection system. In practice applying it, means implementing an approach both predictive and evolutionary - that relies essentially on a prudent and responsible state of mind. the formal expression of this process, called optimization procedure, implies and indispensable tool for its implementation: the system of monetary values for the unit of collective dose. During the last few years, feed ALARA principle means that a global work management approach must be adopted, considering together all factors contributing to radiation dose. In the nuclear field, the ALARA approach appears to be more successful when implemented in the framework of a managerial approach through structure ALARA programmes. Outside the nuclear industry it is necessary to clearly define priorities through generic optimisation studies and ALARA audits. At the international level much efforts remain to be done to expand efficiently the ALARA process to internal exposure as well as to public exposure. (author) 2 graphs, 5 figs., 3 tabs.

  6. Results of the activities of the Scientific and Technical Coordination Council for Radiation Technique and Technology

    Energy Technology Data Exchange (ETDEWEB)

    Sille, A K [Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Moscow

    1977-03-01

    It is reported on the activities of the Scientific and Technical Coordination Council for Radiation Technique and Technology (STCC-RTT) of the CMEA Permanent Commission for the Peaceful Uses of Atomic Energy according to the programme 1971 to 1975. The STCC-RTT is concerned with technical applications such as radiation sterilization, food irradiation, radiation-induced chemical processes etc. The main tasks which have to be solved within the period from 1976 to 1980 are outlined.

  7. Intensity modulated radiation therapy for squamous cell carcinoma of the vulva: Treatment technique and outcomes

    Directory of Open Access Journals (Sweden)

    Yuan James Rao, MD

    2017-04-01

    Conclusions: IMRT for vulvar cancer is associated with high rates of LRC in the postoperative setting and limited radiation-related toxicity. Durable LRC of disease after definitive IMRT remains challenging, and several refinements to our treatment technique are suggested.

  8. Proceedings of the Meeting on Techniques and Applications of Synchrotron Radiation

    International Nuclear Information System (INIS)

    1983-01-01

    Several techniques and applications of the synchrotron radiation used in Physics, Biophysics and Chemistry are extensively discussed. The major part of the subjects of the works treat with the possible implantation of a national synchrotron radiation laboratory in Brazil. (L.C.) [pt

  9. Radiation protection in newer medical imaging techniques: Cardiac CT

    International Nuclear Information System (INIS)

    2008-01-01

    Medical imaging has seen many developments as it has evolved since the mid-1890s. In the last 30-40 years, the pace of innovation has increased, starting with the introduction of computed tomography (CT) in the early 1970s. During the last decade, the rate of change has accelerated further, in terms of continuing innovation and its global application. Most patient exposure now arises from practices that barely existed two decades ago. These developments are evident in the technology on which this volume is based - multislice/detector CT scanning and its application in cardiac imaging. However, this advance is achieved at the cost of a radiation burden to the individual patient, and possibly to the community, if its screening potential is exploited. Much effort will be required to ensure that the undoubted benefit of this new practice will not pose an undue level of detriment to the individual in multiple examinations. For practitioners and regulators, it is evident that innovation has been driven by both the imaging industry and an increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practices lag (inevitably) behind the industrial and clinical innovations. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill this growing vacuum, by bringing up to date and timely advice from experienced practitioners to bear on the problems involved. The advice in this report has been developed as part of the IAEA's statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for the worldwide application of these standards. The Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) were issued by the IAEA and co-sponsored by organizations including the Food and Agriculture

  10. Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique

    Directory of Open Access Journals (Sweden)

    Li Yen-Yao

    2013-01-01

    Full Text Available Abstract Background Percutaneous vertebroplasty (PV requires relatively lengthy fluoroscopic guidance, which might lead to substantial radiation exposure to patients or operators. The two-fluoroscopic technique (two-plane radiographs obtained using two fluoroscopes during PV can provide simultaneous two-planar projections with reducing operative time. However, the two-fluoroscopic technique may expose the operator or patient to increased radiation dose. The aim of this study was to quantify the amount of radiation exposure to the patient or operator that occurs during PV using one- vs. two-fluoroscopic technique. Methods Two radiation dosimeters were placed on the right flank of each patient and on the upper sternum of each operator during 26 single-level PV procedures by one senior surgeon. The use of two-fluoroscopic technique (13 patients and one-fluoroscopic technique (13 patients were allocated in a consecutive and alternative manner. The operative time and mean radiation dose to each patient and operator were monitored and compared between groups. Results Mean radiation dose to the patient was 1.97 ± 1.20 mSv (95% CI, 0.71 to 3.23 for the one-fluoroscopic technique group vs. 0.95 ± 0.34 mSv (95% CI, 0.85 to 1.23 for the two-fluoroscopic technique group (P =0.031. Mean radiation dose to the operator was 0.27 ± 0.12 mSv (95% CI, 0.17–0.56 for the one-fluoroscopic technique group vs. 0.25 ± 0.14 mSv (95% CI, 0.06–0.44 for the two-fluoroscopic technique group (P = 0.653. The operative time was significantly different between groups: 47.15 ± 13.48 min (range, 20–75 for the one-fluoroscopic technique group vs. 36.62 ± 8.42 min (range, 21–50 for the two-fluoroscopic technique group (P =0.019. Conclusion Compared to the one-fluoroscopic technique, the two-fluoroscopic technique used during PV provides not only shorter operative times but also reduces the radiation exposure to the patient. There was no

  11. Calibration technique for radiation measurements in vacuum ultraviolet - soft x-ray region

    International Nuclear Information System (INIS)

    Mizui, Jun-ichi

    1986-05-01

    This is a collection of the papers presented at the workshop on ''Calibration Technique for Radiation Measurements in Vacuum Ultraviolet - Soft X-ray Region'' held at the Institute of Plasma Physics, Nagoya University, on December 19 - 20, 1985, under the Collaborating Research Program at the Institute. The following topics were discussed at the workshop: the needs for the calibration of plasma diagnostic devices, present status of the calibration technique, use of the Synchrotron Orbit Radiations for radiometry, and others. (author)

  12. Multiple group radiator and hybrid test heads, possibilities of combining the array technique

    International Nuclear Information System (INIS)

    Wuestenberg, H.

    1993-01-01

    This article is intended to show the important considerations, which led to the development of the multichannel group radiator technique. Trends in development and the advantages and disadvantages of the different possibilities are introduced, against the background of experience now available for these configurative variants of ultrasonic test heads. For this reason, a series of experiences and arguments is reported, from the point of view of the developer of the multi-channel group radiator technique. (orig./HP) [de

  13. Techniques and radiation dose in CT examinations of adult patients

    International Nuclear Information System (INIS)

    Elameen, S. E. A.

    2010-06-01

    The use of CT in medical diagnosis delivers radiation dose to patients that are higher than those from other radiological procedures. Lake of optimized protocols could be an additional source of increased dose. The aim of this study was to measure radiation doses in CT examination of the adults in three Sudanese hospitals. Details were obtained from approximately 160 CT examination carried out in 3 hospitals (3 CT scanners). Effective dose was calculated for each examination using CT dose indices. exposure related parameters and CT D1- to- effective dose conversion factors. CT air kerma index (CT D1) and dose length products (DLP) determined were below the established international reference dose levels. The mean effective doses in this study for the head, chest, and abdomen are 0.82, 3.7 and 5.4 mGy respectively. These values were observed that the effective dose per examination was lower in Sudan than in other countries. The report of a CT survey done in these centers indicates that the mean DLP values for adult patients were ranged from 272-460 mGy cm (head) 195-995 mGy cm (chest), 270-459 mGy cm (abdomen). There are a number of observed parameters that greatly need optimization, such as minimize the scan length, without missing any vital anatomical regions, modulation of exposure parameters (kV, mA, exposure time, and slice thickness) based on patient size and age. Another possible method is through use of contrast media only to optimize diagnostic yield. The last possible method is the use of radio protective materials for protection however, in order to achieve the above optimization strategies: there is great demand to educate CT personnel on the effects of scan parameter settings on radiation dose to patients and image quality required for accurate diagnosis. (Author)

  14. Sterilization techniques without heating (ultraviolet ray, radiation and ozone)

    International Nuclear Information System (INIS)

    Ito, Hitoshi

    1991-01-01

    The recent demand of consumers for processed foods is characterized by the intention for health and nature, besides, the demand for low sweetness, salt reduction, no additive and freshness becomes strong. In view of the control of microorganisms in products, all these become the negative factors. Accordingly, in order to overcome them, it is urgently desired to develop new technology or to improve conventional methods. As to heating sterilization, the uniform temperature treatment to the inside of foods is difficult, and it cannot be applied to perishables. The high temperature sterilization above 120degC causes the change in nutrition composition and physical properties. Ultraviolet ray and ozone can be used for the sterilization of food surface and powder and liquid foods. Radiation treatment can be applied to packed foods and frozen foods as well as food surface. The principle and the fields of application of ultraviolet ray sterilization, radiation sterilization and ozone sterilization are reported. In the mechanism of these methods, the action to DNA and oxidation are common. (K.I.)

  15. TLD array for precise dose measurements in stereotactic radiation techniques

    International Nuclear Information System (INIS)

    Ertl, A.; Kitz, K.; Griffitt, W.; Hartl, R.F.E.; Zehetmayer, M.

    1996-01-01

    We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be useful for phantom or tissue model studies on the spatial dose distribution in confined radiation targets as used in stereotactic radiotherapy. (author)

  16. Synchrotron radiation X-ray microfluorescence techniques

    Indian Academy of Sciences (India)

    Synchrotron X-ray imaging systems with fluorescence techniques was developed for biomedical researches in Brazilian Synchrotron Laboratory. An X-ray fluorescence microtomography system was implemented to analyse human prostate and breast samples and an X-ray microfluorescence system was implemented to ...

  17. The program director and accreditation

    International Nuclear Information System (INIS)

    Tristan, T.A.; Capp, M.P.; Krabbenhoft, K.L.; Armbruster, J.S.

    1987-01-01

    Field Survey is contrasted with the Specialist Site Visitor. The discussion addresses the reasons for different types of surveys and how the surveys and the Hospital Information Form are used in evaluating a graduate residency program in radiology for accreditation. The Residency Review Committee for Radiology (RRC) and the staff of the Accreditation Council for Graduate Medical Education (ACGME) of Residencies in Radiology offer a program for program directors and other interested leaders in graduate programs in radiology. The authors explain the review and accreditation process for residencies in radiology with special emphasis on the preparation for inspection by accurate and full completion of the Hospital Information Form on which the program is judged, and the nature of the inspection procedures

  18. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  19. Vehicle-borne survey techniques for background radiations

    International Nuclear Information System (INIS)

    Minato, Susumu

    1995-01-01

    This paper presented methods for converting count rates measured inside cars and trains in the natural environment into outdoor terrestrial gamma-ray dose rates. First, (1) the method of calibration for a survey meter is described to be applicable to various geological terrains. Next, the regression formulas were acquired experimentally to correct (2) the shielding effects of cars and trains, and (3) the influence of pavements and ballasts. Furthermore, (4) a new method for removing interfering radiation components emitted from cliffs and tunnels was proposed, and the errors in the calculations were evaluated with numerical experiments. In addition, the degree of influence from the cliff was represented with the angle of elevation subtended to the detector. For the items (2)-(4), in particular, it could be explained with simple models that those methods are reasonable. The method for evaluating simply and accurately cosmic-ray dose rates by means of a portable barometer was also described. (author)

  20. Techniques of radiation induced haploid breeding of wheat

    International Nuclear Information System (INIS)

    Xuan Pu; Xu Liyuan; Qu Shihong; Yu Guirong; Yin Chunrong; Yue Chunfang

    2000-01-01

    With the treatment of different doses of 60 Co γ-ray irradiation to F 1 hybrid seeds and donor plants from M 1 F 1 or M 2 F 2 , wheat anther culture was made based on the media of MW 14 and modified MS. A series of studies on the applied doses of radiation induction, low temperature treatment on donor spikes and calli, variable temperature induced incubation and yield of pollen callus and calli giving green plant lets, pollen plant lets control over summertime and pollen plant let transplantation were carried out in order to increase the efficiency of obtaining double haploid-pure diploid plant lets of wheat with stable heredity and propagation. Theses plant lets could be used directly in rapid breeding

  1. Radiation and isotopic techniques in the study and control of piroplasms of cattle: a review

    International Nuclear Information System (INIS)

    Irvin, A.D.; Brocklesby, D.W.; Purnell, R.E.

    1979-01-01

    Radiation and isotopic techniques have been used in a number of ways to study Babesia and Theileria parasites (piroplasms), and in attempts to vaccinate animals against diseases induced by these agents. Work involving the piroplasm infections of cattle is reviewed in this paper. Some success has been achieved by using radiation to modify tick or bovine stages of parasites, for use as potential vaccines. Radiation has also been used to induce immuno-suppression in laboratory animals, in an effort to render them susceptible to bovine piroplasms, particularly Theileria. Isotope tracer techniques have been used for labelling parasites, and for studying metabolic pathways. Encouraging results, particularly with regard to vaccine development, indicate the importance of radiation techniques in the study and control of piroplasms of cattle. (Auth.)

  2. Study on Production of Useful Metabolites by Development of Advanced Cell Culture Techniques Using Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Byung Yeoup; Kim, J. H.; Lee, S. S.; Shyamkumar, B.; An, B. C.; Moon, Y. R.; Lee, E. M.; Lee, M. H.

    2009-02-15

    The purpose of this project is improvement of investigation, materialization and evaluation techniques on effectiveness for functional natural compounds throughout development of tissue/cell culture techniques for mass production of useful metabolites using radiation. Research scope includes 1) Development of a technique for radiation tissue and cell culture, 2) Database construction for radiation response in plants and radiation effects, 3) Construction of general-purpose national based techniques of cell culture technique using radiation. Main results are as follow: Establishment of a tissue culture system (Rubus sp., Lithospermum erythrorhizon, and Rhodiola rosea); characterization of radiation activated gene expression from cultivated bokbunja (Rubus sp.) and Synechocystis sp., identification of gamma-ray induced color change in plants; identification of sensitivity to gamma-ray from Omija (Schisandra chinensis) extract; identification of the response of thylakoid proteins to gamma-ray in spinach and Arabidopsis; identification of gamma-ray induced gene relating to pigment metabolism; characterization of different NPQ changes to gamma-irradiated plants; verification of the effects of rare earth element including anti-bacterial and anti-fungal properties and as a growth enhancer; identification of changes in the growth of gamma-irradiated Synechocystis; and investigation of liquid cell culture conditions from Rhodiola rosea

  3. Study on Production of Useful Metabolites by Development of Advanced Cell Culture Techniques Using Radiation

    International Nuclear Information System (INIS)

    Chung, Byung Yeoup; Kim, J. H.; Lee, S. S.; Shyamkumar, B.; An, B. C.; Moon, Y. R.; Lee, E. M.; Lee, M. H.

    2009-02-01

    The purpose of this project is improvement of investigation, materialization and evaluation techniques on effectiveness for functional natural compounds throughout development of tissue/cell culture techniques for mass production of useful metabolites using radiation. Research scope includes 1) Development of a technique for radiation tissue and cell culture, 2) Database construction for radiation response in plants and radiation effects, 3) Construction of general-purpose national based techniques of cell culture technique using radiation. Main results are as follow: Establishment of a tissue culture system (Rubus sp., Lithospermum erythrorhizon, and Rhodiola rosea); characterization of radiation activated gene expression from cultivated bokbunja (Rubus sp.) and Synechocystis sp., identification of gamma-ray induced color change in plants; identification of sensitivity to gamma-ray from Omija (Schisandra chinensis) extract; identification of the response of thylakoid proteins to gamma-ray in spinach and Arabidopsis; identification of gamma-ray induced gene relating to pigment metabolism; characterization of different NPQ changes to gamma-irradiated plants; verification of the effects of rare earth element including anti-bacterial and anti-fungal properties and as a growth enhancer; identification of changes in the growth of gamma-irradiated Synechocystis; and investigation of liquid cell culture conditions from Rhodiola rosea

  4. Sterile insect technique and radiation in insect control

    International Nuclear Information System (INIS)

    1982-01-01

    Out of 39 papers and 6 summaries of the poster presentations published in this proceeding series, 23 respectively fall within the INIS subject scope. Four main topics were covered: a review of the sterile insect technique against various insect pests; its application to tsetse flies in eradication programmes; quality control of mass-reared insects for release; and the development of genetic approaches to insect mass rearing and control. Other topics emphasized integrated pest management, computer models and radioisotope labelling

  5. An introduction to synchrotron radiation techniques and applications

    CERN Document Server

    Willmott, Philip

    2011-01-01

    This book introduces the reader to the basic concepts of the generation and manipulation of synchrotron light, its interaction with matter, and the application of synchrotron light in the “classical” techniques, while including some of the most modern technological developments. As much as possible, complicated mathematical derivations and formulas are avoided. A more heuristic approach is adopted, whereby the general physical reasoning behind the equations is highlighted.

  6. Development of food preservation and processing techniques by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Myung Woo; Lee, Ju Woon; Kim, Dong Ho [KAERI, Taejon (Korea, Republic of); Yook, Hong Sun [Chungnam National Univ., Taejon (Korea, Republic of); Kim, Hak Soo [Sogang Univ., Seoul (Korea, Republic of); Lee, Cherl Ho; Park, Hyun Jin [Korea Univ., Seoul (Korea, Republic of); Kang, Il Jun [Hallym Univ., Chuncheon (Korea, Republic of); Kwon, Jung Ho [Kyungbook National Univ., Taegu (Korea, Republic of)

    2002-05-01

    To secure national food resources, development of energy-saving food processing and preservation technologies, establishment of method on improvement of national health and safety by development of alternative techniques of chemicals and foundation of the production of hygienic food and public health related products by irradiation technology were studied. Results at current stage are following; Processing techniques of low salted and fermented fish using gamma irradiation were developed and superiority of using irradiation to conventional food processing methods was established. Processing technique of value-added functional materials for the manufacture of food or public health products using RT/BT/NT combination technology was developed. The basic theories for the technology development to reduce toxic or undesirable compounds in food such as allergy or carcinogens were established. Exterminating methods of quarantine organisms in herbs/spices was established and the quality evaluation and detection conditions in quarantine treatment were set. From the studies on 'program of public understanding' based on safety of the gamma irradiated food, the information for public relation in enlargement of consumer acceptance/implementation and the peaceful use of nuclear energy were secured. Results from the research project will contribute on improvement of competency of domestic food industry and export market. The results also expect the improvement of public health by prevention of food borne diseases and enhancement of national economy and industry by increase of direct/indirect productivity.

  7. Development of food preservation and processing techniques by radiation

    International Nuclear Information System (INIS)

    Byun, Myung Woo; Lee, Ju Woon; Kim, Dong Ho; Yook, Hong Sun; Kim, Hak Soo; Lee, Cherl Ho; Park, Hyun Jin; Kang, Il Jun; Kwon, Jung Ho

    2002-05-01

    To secure national food resources, development of energy-saving food processing and preservation technologies, establishment of method on improvement of national health and safety by development of alternative techniques of chemicals and foundation of the production of hygienic food and public health related products by irradiation technology were studied. Results at current stage are following; Processing techniques of low salted and fermented fish using gamma irradiation were developed and superiority of using irradiation to conventional food processing methods was established. Processing technique of value-added functional materials for the manufacture of food or public health products using RT/BT/NT combination technology was developed. The basic theories for the technology development to reduce toxic or undesirable compounds in food such as allergy or carcinogens were established. Exterminating methods of quarantine organisms in herbs/spices was established and the quality evaluation and detection conditions in quarantine treatment were set. From the studies on 'program of public understanding' based on safety of the gamma irradiated food, the information for public relation in enlargement of consumer acceptance/implementation and the peaceful use of nuclear energy were secured. Results from the research project will contribute on improvement of competency of domestic food industry and export market. The results also expect the improvement of public health by prevention of food borne diseases and enhancement of national economy and industry by increase of direct/indirect productivity

  8. Development of food preservation and processing techniques by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Myung Woo; Lee, Ju Woon; Kim, Dong Ho [KAERI, Taejon (Korea, Republic of); Yook, Hong Sun [Chungnam National Univ., Taejon (Korea, Republic of); Kim, Hak Soo [Sogang Univ., Seoul (Korea, Republic of); Lee, Cherl Ho; Park, Hyun Jin [Korea Univ., Seoul (Korea, Republic of); Kang, Il Jun [Hallym Univ., Chuncheon (Korea, Republic of); Kwon, Jung Ho [Kyungbook National Univ., Taegu (Korea, Republic of)

    2002-05-01

    To secure national food resources, development of energy-saving food processing and preservation technologies, establishment of method on improvement of national health and safety by development of alternative techniques of chemicals and foundation of the production of hygienic food and public health related products by irradiation technology were studied. Results at current stage are following; Processing techniques of low salted and fermented fish using gamma irradiation were developed and superiority of using irradiation to conventional food processing methods was established. Processing technique of value-added functional materials for the manufacture of food or public health products using RT/BT/NT combination technology was developed. The basic theories for the technology development to reduce toxic or undesirable compounds in food such as allergy or carcinogens were established. Exterminating methods of quarantine organisms in herbs/spices was established and the quality evaluation and detection conditions in quarantine treatment were set. From the studies on 'program of public understanding' based on safety of the gamma irradiated food, the information for public relation in enlargement of consumer acceptance/implementation and the peaceful use of nuclear energy were secured. Results from the research project will contribute on improvement of competency of domestic food industry and export market. The results also expect the improvement of public health by prevention of food borne diseases and enhancement of national economy and industry by increase of direct/indirect productivity.

  9. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    International Nuclear Information System (INIS)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor; Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette

    2017-01-01

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D mean ), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D mean was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m 2 , with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D mean exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [de

  10. Laboratory accreditation in developing economies

    International Nuclear Information System (INIS)

    Loesener, O.

    2004-01-01

    Full text: Accreditation of laboratories has been practiced for well over one hundred years with the primary objective of seeking a formal recognition for the competence of a laboratory to perform specified tests or measurements. While first accreditation schemes intended initially to serve only the immediate needs of the body making the evaluation with the purpose of minimizing testing and inspection to be conducted by laboratories, third-party accreditation enables a laboratory to demonstrate its capability as well as availability of all necessary resources to undertake particular tests correctly and that is managed in such a way that it is likely to do this consistently, taking into consideration standards developed by national and international standards-setting bodies. The international standard ISO/IEC 17025 and laboratory accreditation are concerned with competence and quality management of laboratories only, thus requiring a single common set of criteria applicable to them. Quality assurance is therefore fully relevant to laboratories in general and analytical laboratories in particular; it should not be confused with the certification approach according to ISO/IEC 9000 family of standards, that is concerned with quality management applicable to any organization as a whole. The role of laboratory accreditation can be manifold, but in all cases the recipient of the test report needs to have confidence that the data in it is reliable, particularly if the test data is important in a decision-making process. As such, it offers a comprehensive way to ensure: - the availability of managerial and technical staff with the authority and resources needed; - the effectiveness of equipment management, traceability of measurement and safety procedures; - the performance of tests, taking into consideration laboratory accommodation and facilities as well as laboratory practices. The presentation will include also some practical aspects of quality management system

  11. A journey to accreditation: is ISO 15189 laboratory accreditation ...

    African Journals Online (AJOL)

    Through this journey we comprehend that the first step before accreditation is building enthusiastic team with education on quality management system. Other steps include selection of methods, developing or improving the metrology system, definition and structure of documents, preparation of a quality manual, SOPs, ...

  12. 22 CFR 96.63 - Renewal of accreditation or approval.

    Science.gov (United States)

    2010-04-01

    ... for renewal in a timely fashion. Before deciding whether to renew the accreditation or approval of an... accrediting entity or the Secretary during its most current accreditation or approval cycle, the accrediting...

  13. Direct time-domain techniques for transient radiation and scattering

    International Nuclear Information System (INIS)

    Miller, E.K.; Landt, J.A.

    1976-01-01

    A tutorial introduction to transient electromagnetics, focusing on direct time-domain techniques, is presented. Physical, mathematical, numerical, and experimental aspects of time-domain methods, with emphasis on wire objects excited as antennas or scatters are examined. Numerous computed examples illustrate the characteristics of direct time-domain procedures, especially where they may offer advantages over procedures in the more familiar frequency domain. These advantages include greater solution efficiency for many types of problems, the ability to handle nonlinearities, improved physical insight and interpretability, availability of wide-band information from a single calculation, and the possibility of isolating interactions among various parts of an object using time-range gating

  14. Clinical Psychology Training: Accreditation and Beyond.

    Science.gov (United States)

    Levenson, Robert W

    2017-05-08

    Beginning with efforts in the late 1940s to ensure that clinical psychologists were adequately trained to meet the mental health needs of the veterans of World War II, the accreditation of clinical psychologists has largely been the province of the Commission on Accreditation of the American Psychological Association. However, in 2008 the Psychological Clinical Science Accreditation System began accrediting doctoral programs that adhere to the clinical science training model. This review discusses the goals of accreditation and the history of the accreditation of graduate programs in clinical psychology, and provides an overview of the evaluation procedures used by these two systems. Accreditation is viewed against the backdrop of the slow rate of progress in reducing the burden of mental illness and the changes in clinical psychology training that might help improve this situation. The review concludes with a set of five recommendations for improving accreditation.

  15. ORIGINAL ARTICLES Academic hospital accreditation strengthens ...

    African Journals Online (AJOL)

    This case study originated from the combined experiences of the accreditation process of a ... (iv) the benefits of hospital accreditation and quality management. The study ... Tertiary healthcare is in a crisis after nearly 3 decades of neglect,2,3.

  16. Hybrid hydrogels produces by ionizing radiation technique for drug delivery

    International Nuclear Information System (INIS)

    Oliveira, M.J.A.; Parra, D.F.; Lugao, A.B.; Amato, V.S.

    2011-01-01

    Complete text of publication follows. Interest in the preparation of biocompatible hydrogels with various properties has increased considerably in recent years due to their versatile applications in biomedicine, biotechnology, pharmacy, agriculture and controlled release of drugs. The use of hydrogels matrices for particular drug-release applications has been investigated with the synthesis of modified polymeric hydrogel of PVAl, PEG and 0.5, 1.0 and 1.5% nano-clay. They were processed using gamma radiation from Cobalt-60 source at 25 kGy dose. The characterization of the hydrogels was conducted and toxicity was evaluated. The dried hydrogel was analyzed for thermogravimetry analysis (TGA), infrared spectroscopic analysis (FTIR), swelling in solutions of different pH and gel determinations. The membranes have no toxicity and the gel content reveals the reticulation. The nano-clay influences directly the equilibrium swelling. Acknowledgement: Support by FAPESP 09/50926-1, FAPESP Process no. 2009/18627-4 CNPq Process no. 310849/2009-8, CAPES, IPEN/CNEN.

  17. Techniques for Pump-Probe Synchronisation of Fsec Radiation Pulses

    CERN Document Server

    Schlarb, Holger

    2005-01-01

    The increasing interest on the production of ultra-short photon pulses in future generations of Free-Electron Lasers operating in the UV, VUV or X-ray regime demands new techniques to reliably measure and control the arrival time of the FEL-pulses at the experiment. For pump-probe experiments using external optical lasers the desired synchronisation is in the order of tens of femtoseconds, the typical duration of the FEL pulse. Since, the accelerators are large scale facilities of the length of several hundred meters or even kilometers, the problem of synchronisation has to be attacked twofold. First, the RF acceleration sections upstream of the magnetic bunch compressors need to be stabilised in amplitude and phase to high precision. Second, the remain electron beam timing jitter needs to be determined with femtosecond accuracy for off-line analysis. In this talk, several techniques using the electron or the FEL beam to monitor the arrival time are presented, and the proposed layout of the synchronisation sy...

  18. Radiation technique to determine early peopling of Brazil

    International Nuclear Information System (INIS)

    Watanabe, Shigueo; Ayta, Walter E.F.; Callata, Henry J.C.; Farias, Thiago M.B.; Gennari, Roseli F.; Etchevarne, Carlos A.

    2009-01-01

    Peopling American Continent and in particular of Brazil has been subject of research for a long time. With the results of dating of several pertinent materials many theories have been proposed. In Brazil, there is a National Park (Serra da Capivara Park) which is worldwide known due to thousands of wall paintings, most of them in rockshelters. N. Guidon, head of the Serra da Capivara National Park, found charcoal pellets in several archaeological sites and they were dated by radiocarbon technique. Ages ranging from 6 to 48 ka have been found. In one of the shelter a thin white covering was found that was proved to be calcite. This calcite was dated by Thermoluminescence and Electron Paramagnetic Resonance techniques and ages of 35 to 36 ka were obtained. In 2007, thin calcite covering wall paintings found in Iraquara County, Bahia state, has been dated. Ages of 50 ka have been obtained. The proposal of this work is that the early settlers crossed Atlantic Ocean from westernmost point of African Continent to easternmost point in Brazil more than 50000 years ago. The theory here proposed is possible once the distance between these two points is less than 3000 km distance far shorter than from Siberia to South America as proposed by other researchers.(author)

  19. Accreditation and Educational Quality: Are Students in Accredited Programs More Academically Engaged?

    Science.gov (United States)

    Cole, James S.; Cole, Shu T.

    2008-01-01

    There has been a great deal of debate regarding the value of program accreditation. Two research questions guided this study: 1) are students enrolled in accredited parks, recreation, and leisure programs more academically engaged than students enrolled in non-accredited programs, and 2) do students enrolled in accredited parks, recreation, and…

  20. Utilization technique of 'radiation management manual in medical field (2012).' What should be learnt from the Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Kikuchi, Toru

    2014-01-01

    From the abstract of contents of the 'Radiation management manual in medical field (2012),' the utilization technique of the manual is introduced. Introduced items are as follows: (1) Exposure management; exposure management for radiation medical workers, patients, and citizens in the medical field, and exposure management for radiation workers and citizens involved in the emergency work related to the Fukushima nuclear accident, (2) Health management; health management for radiation medical workers, (3) Radiation education: Education/training for radiation medical workers, and radiation education for health care workers, (4) Accident and emergency measures; emergency actions involved in the radiation accidents and radiation medicine at medical facilities

  1. The importance of having a flexible scope ISO 15189 accreditation and quality specifications based on biological variation – the case of validation of the biochemistry analyzer Dimension Vista

    OpenAIRE

    Fernandez-Calle, Pilar; Pelaz, Sandra; Oliver, Paloma; Alcaide, Maria Jose; Gomez-Rioja, Ruben; Buno, Antonio; Iturzaeta, Jose Manuel

    2013-01-01

    Introduction: Technological innovation requires the laboratories to ensure that modifications or incorporations of new techniques do not alter the quality of their results. In an ISO 15189 accredited laboratory, flexible scope accreditation facilitates the inclusion of these changes prior to accreditation body evaluation. A strategy to perform the validation of a biochemistry analyzer in an accredited laboratory having a flexible scope is shown. Materials and methods: A validation procedur...

  2. Probing droplets on superhydrophobic surfaces by synchrotron radiation scattering techniques

    KAUST Repository

    Accardo, Angelo

    2014-06-10

    Droplets on artificially structured superhydrophobic surfaces represent quasi contact-free sample environments which can be probed by X-ray microbeams and nanobeams in the absence of obstructing walls. This review will discuss basic surface wettability concepts and introduce the technology of structuring surfaces. Quasi contact-free droplets are compared with contact-free droplets; processes related to deposition and evaporation on solid surfaces are discussed. Droplet coalescence based on the electrowetting effect allows the probing of short-time mixing and reaction processes. The review will show for several materials of biological interest that structural processes related to conformational changes, nucleation and assembly during droplet evaporation can be spatially and temporally resolved by raster-scan diffraction techniques. Orientational ordering of anisotropic materials deposited during solidification at pinning sites facilitates the interpretation of structural data. 2014 International Union of Crystallography.

  3. Manufacturing Techniques of Ge(Li) Gamma radiation detectors

    International Nuclear Information System (INIS)

    Marti, G.V.; Gimenez, C.R.

    1981-01-01

    A method is shown, to make detectors of germanium-lithium with a size up to 50 cu cm. A detailed description of the techniques used in the different stages of the process is shown as well as the results attained with several detectors. Resolutions of 2,7 and 5,5 keV and efficiencies between 3 and 8% for an energy of 1,33 MeV have been attained. An attempt was made to relate said parameters with the difficulties found during the fabrication of the detectors and the features of the original material, with the purpose to set criterions that allow to acknowledge the crystals more easily compensatable, and when finished would yield the best resolution and efficiency. A summary of the most important features and construction details is given showing some spectrum of the best crystals. Finally the results attained are discussed and some of the conclusions are extracted. (V.B.) [es

  4. Probing droplets on superhydrophobic surfaces by synchrotron radiation scattering techniques

    KAUST Repository

    Accardo, Angelo; Di Fabrizio, Enzo M.; Limongi, Tania; Marinaro, Giovanni; Riekel, Christian

    2014-01-01

    Droplets on artificially structured superhydrophobic surfaces represent quasi contact-free sample environments which can be probed by X-ray microbeams and nanobeams in the absence of obstructing walls. This review will discuss basic surface wettability concepts and introduce the technology of structuring surfaces. Quasi contact-free droplets are compared with contact-free droplets; processes related to deposition and evaporation on solid surfaces are discussed. Droplet coalescence based on the electrowetting effect allows the probing of short-time mixing and reaction processes. The review will show for several materials of biological interest that structural processes related to conformational changes, nucleation and assembly during droplet evaporation can be spatially and temporally resolved by raster-scan diffraction techniques. Orientational ordering of anisotropic materials deposited during solidification at pinning sites facilitates the interpretation of structural data. 2014 International Union of Crystallography.

  5. 7 CFR 205.506 - Granting accreditation.

    Science.gov (United States)

    2010-01-01

    ..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) ORGANIC FOODS PRODUCTION ACT PROVISIONS NATIONAL ORGANIC PROGRAM Accreditation of Certifying Agents § 205.506 Granting accreditation. (a... accreditation as provided in § 205.510(c), the certifying agent voluntarily ceases its certification activities...

  6. The Role of Accreditation in Consumer Protection.

    Science.gov (United States)

    Warner, W. Keith; Andersen, Kay J.

    1982-01-01

    Upper-level college administrators in the Western accreditation region were surveyed about how well the Western Association of Schools and Colleges (WASC) served its constituency. Questions concerned consumer protection as an objective of accreditation, emphasis on disseminating information about the accreditation process, and potential policy…

  7. Accreditation - ISO/IEC 17025

    Science.gov (United States)

    Kaus, Rüdiger

    This chapter gives the background on the accreditation of testing and calibration laboratories according to ISO/IEC 17025 and sets out the requirements of this international standard. ISO 15189 describes similar requirements especially tailored for medical laboratories. Because of these similarities ISO 15189 is not separately mentioned throughout this lecture.

  8. Study on production of useful metabolites by development of advanced cell culture techniques using radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Byung Yeoup; Kim, Jin Hong; Lee, Seung Sik; Kim, Jae Sung; An, Byung Chull; Moon, Yu Ran; Lee, Eun Mi; Lee, Min Hee; Lee, Jae Tack [KAERI, Daejeon (Korea, Republic of)

    2010-02-15

    The purpose of this project is improvement of investigation, materialization and evaluation techniques on effectiveness for functional natural compounds throughout development of tissue/cell culture techniques for mass production of useful metabolites using radiation. Research scope includes 1) Development of a technique for radiation tissue and cell culture, 2) Database construction for radiation response in plants and radiation effects, 3) Construction of general-purpose national based techniques of cell culture technique using radiation. Main results are as follow: mass culture of the adventitious roots of mountain ginseng (Panax ginseng C. A. Meyer) roots using rare earth elements in bioreactor: characterization of a transcription factor EoP gene from centipedegrass and the transcription regulation of LexA from Synechocystis sp PCC6803 and E. coli: identification of gamma-ray induced hydrogenase synthesis in hox gene transformed E. coli: transformation and the selection of the EoP transgene from Arabidopsis, rice and lettuce: Identification of the maysin and maysin derivatives in centipedegrass: characterization of gamma-ray induced color change in Taxus cuspidata: verification of the expression of antioxidant proteins (POD, APX and CAT) to gamma-ray in Arabidopsis: comparison of the response of the expression level to gamma-ray or H{sub 2}O{sub 2} in Arabidopsis; verification of the responses and effects to gamma-ray from plants (analysis of NPQ and ROS levels): the development method for rapidly enhancing maysin content of centipede grass; establishment of mass culture system for red beet

  9. Study on production of useful metabolites by development of advanced cell culture techniques using radiation

    International Nuclear Information System (INIS)

    Chung, Byung Yeoup; Kim, Jin Hong; Lee, Seung Sik; Kim, Jae Sung; An, Byung Chull; Moon, Yu Ran; Lee, Eun Mi; Lee, Min Hee; Lee, Jae Tack

    2010-02-01

    The purpose of this project is improvement of investigation, materialization and evaluation techniques on effectiveness for functional natural compounds throughout development of tissue/cell culture techniques for mass production of useful metabolites using radiation. Research scope includes 1) Development of a technique for radiation tissue and cell culture, 2) Database construction for radiation response in plants and radiation effects, 3) Construction of general-purpose national based techniques of cell culture technique using radiation. Main results are as follow: mass culture of the adventitious roots of mountain ginseng (Panax ginseng C. A. Meyer) roots using rare earth elements in bioreactor: characterization of a transcription factor EoP gene from centipedegrass and the transcription regulation of LexA from Synechocystis sp PCC6803 and E. coli: identification of gamma-ray induced hydrogenase synthesis in hox gene transformed E. coli: transformation and the selection of the EoP transgene from Arabidopsis, rice and lettuce: Identification of the maysin and maysin derivatives in centipedegrass: characterization of gamma-ray induced color change in Taxus cuspidata: verification of the expression of antioxidant proteins (POD, APX and CAT) to gamma-ray in Arabidopsis: comparison of the response of the expression level to gamma-ray or H 2 O 2 in Arabidopsis; verification of the responses and effects to gamma-ray from plants (analysis of NPQ and ROS levels): the development method for rapidly enhancing maysin content of centipede grass; establishment of mass culture system for red beet

  10. Optimized digital filtering techniques for radiation detection with HPGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Salathe, Marco, E-mail: marco.salathe@mpi-hd.mpg.de; Kihm, Thomas, E-mail: mizzi@mpi-hd.mpg.de

    2016-02-01

    This paper describes state-of-the-art digital filtering techniques that are part of GEANA, an automatic data analysis software used for the GERDA experiment. The discussed filters include a novel, nonlinear correction method for ballistic deficits, which is combined with one of three shaping filters: a pseudo-Gaussian, a modified trapezoidal, or a modified cusp filter. The performance of the filters is demonstrated with a 762 g Broad Energy Germanium (BEGe) detector, produced by Canberra, that measures γ-ray lines from radioactive sources in an energy range between 59.5 and 2614.5 keV. At 1332.5 keV, together with the ballistic deficit correction method, all filters produce a comparable energy resolution of ~1.61 keV FWHM. This value is superior to those measured by the manufacturer and those found in publications with detectors of a similar design and mass. At 59.5 keV, the modified cusp filter without a ballistic deficit correction produced the best result, with an energy resolution of 0.46 keV. It is observed that the loss in resolution by using a constant shaping time over the entire energy range is small when using the ballistic deficit correction method.

  11. Development of a technique for environmental treatment by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myun Joo; Jin, J. H.; Jung, Y. D. and others

    2000-04-01

    This study was carried out for the development of pilot plant which can produce industrial water from effluent of sewage treatment plant by irradiation. As a basic study, the characteristics on decomposition of organic compounds, decoloration and sterilization of bacteria were evaluated. An additive mainly composed by sponge type of TiO{sub 2} was developed for reduction of irradiation dose and enhancement of removal efficiency of organic compounds. The optimum pilot plant was composed of sysem with gamma irradiation/ozone/additive/ion exchange. The effluent with BOD 20 ppm, COD 25 ppm and color 25 ADMI could be treated to less than 5 ppm and 5 ADMI under the irradiation of 5 kGy. The disinfection of microorganism also could be done perfectively under the same irradiation. A small amount of heavy metal ions and inorganic ions, nitrogen, contained in effluent were removed by ion exchanger. From the operation of pilot plant it could be concluded that irradiation technique can be a good method for the produce of industrial water from effluent.

  12. Probing droplets on superhydrophobic surfaces by synchrotron radiation scattering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Accardo, Angelo [Istituto Italiano di Tecnologia, Via Morego 30, Genova 16163 (Italy); Di Fabrizio, Enzo [KAUST (King Abdullah University of Science and Technology), Jeddah (Saudi Arabia); BIONEM Lab at University Magna Graecia, Campus Salvatore Venuta, Viale Europa 88100, Germaneto-Catanzaro (Italy); Limongi, Tania [KAUST (King Abdullah University of Science and Technology), Jeddah (Saudi Arabia); Marinaro, Giovanni [Istituto Italiano di Tecnologia, Via Morego 30, Genova 16163 (Italy); European Synchrotron Radiation Facility, BP 220, 38043 Grenoble Cedex (France); Riekel, Christian, E-mail: riekel@esrf.fr [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble Cedex (France)

    2014-06-10

    A comprehensive review about the use of micro- and nanostructured superhydrophobic surfaces as a tool for in situ X-ray scattering investigations of soft matter and biological materials. Droplets on artificially structured superhydrophobic surfaces represent quasi contact-free sample environments which can be probed by X-ray microbeams and nanobeams in the absence of obstructing walls. This review will discuss basic surface wettability concepts and introduce the technology of structuring surfaces. Quasi contact-free droplets are compared with contact-free droplets; processes related to deposition and evaporation on solid surfaces are discussed. Droplet coalescence based on the electrowetting effect allows the probing of short-time mixing and reaction processes. The review will show for several materials of biological interest that structural processes related to conformational changes, nucleation and assembly during droplet evaporation can be spatially and temporally resolved by raster-scan diffraction techniques. Orientational ordering of anisotropic materials deposited during solidification at pinning sites facilitates the interpretation of structural data.

  13. Development of a technique for environmental treatment by radiation

    International Nuclear Information System (INIS)

    Lee, Myun Joo; Jin, J. H.; Jung, Y. D. and others

    2000-04-01

    This study was carried out for the development of pilot plant which can produce industrial water from effluent of sewage treatment plant by irradiation. As a basic study, the characteristics on decomposition of organic compounds, decoloration and sterilization of bacteria were evaluated. An additive mainly composed by sponge type of TiO 2 was developed for reduction of irradiation dose and enhancement of removal efficiency of organic compounds. The optimum pilot plant was composed of sysem with gamma irradiation/ozone/additive/ion exchange. The effluent with BOD 20 ppm, COD 25 ppm and color 25 ADMI could be treated to less than 5 ppm and 5 ADMI under the irradiation of 5 kGy. The disinfection of microorganism also could be done perfectively under the same irradiation. A small amount of heavy metal ions and inorganic ions, nitrogen, contained in effluent were removed by ion exchanger. From the operation of pilot plant it could be concluded that irradiation technique can be a good method for the produce of industrial water from effluent

  14. Technique for radiation treatment of exhaust gas due to combustion

    International Nuclear Information System (INIS)

    Machi, Sueo

    1978-01-01

    As the Japanese unique research in the field of preservation of environment, the technique to remove simultaneously sulphur dioxide and nitrogen oxides in exhaust gas using electron beam irradiation is noteworthy. This research was started by the experiment in the central research laboratory of Ebara Manufacturing Co., Ltd., in which it was found that the sulphur dioxide of initial concentration of 1,000 ppm was almost completely vanished when the exhaust gas of heavy oil combustion in a batch type vessel was irradiated for 9 minutes by electron beam. Based on this experiment, JAERI installed a continuous irradiation equipment with a large accelerator, and has investigated the effect of various parameters such as dose rate, irradiation temperature, total dose and agitation. This resulted in the remarkable finding that nitrogen oxides were also completely removed as well as sulphur dioxide when the exhaust gas containing both sulphur dioxide and nitrogen oxides was irradiated for a few seconds. In this case, if water of about 0.3% is added, removal rate of sulphur dioxide is greatly increased. The research group of University of Tokyo obtained other findings concerning removal rates. Then, after the pilot plant stage in Ebara Manufacturing Co., Ltd. from 1974, the test plant of exhaust gas treatment for a sintering machine, having the capacity of 3,000 Nm 3 /hr, has been constructed in Yawata Works of Nippon Steel Corp. This is now operating properly. (Wakatsuki, Y.)

  15. Interstitial radiation therapeutic techniques at Mount Vernon Hospital

    International Nuclear Information System (INIS)

    Denham, J.W.; Strickland, P.; Alderson, A.M.; Hudson, F.R.; Bennett, M.H.

    1982-01-01

    Retrospective analysis of 56 cases of carcinoma on the lateral border of the anterior two thirds of the tongue treated at Mount Vernon Hospital using radium needle implant alone yielded 5-year actuarial survivals of 75.3 per cent in 25 T1N0 cases and 81.8 per cent in 25 T2N0 cases. Five-year actuarial local recurrence of 17.5 per cent was recorded in the T1 group and 35 per cent in the T2 group. Local recurrences were attributed to failure of the implant to encompass extensions of the tumour along the lateral border or into the musculature of the tongue. Five-year actuarial local recurrence of 66.2 per cent was recorded in 18 patients with carcinoma of the breast treated by radium needle implant alone; 4 of these 9 local recurrences occurred at some distance from the treated area and could not be classed as marginal recurrences. A preliminary investigation carried out in 1981 indicated that significant improvements in source distribution, particularly at poorly accessible sites, could be achieved using afterloading techniques. In addition the use of 192 Ir as a source could result in improvements in staff protection. (Auth.)

  16. Study On The Application Of Hydrogel Prepared By Radiation Technique For Fermentation Of Sawdust

    International Nuclear Information System (INIS)

    Le Thuy Trang; Nguyen Huynh Phuong Uyen; Vo Thu Ha; Le Quang Luan

    2011-01-01

    The super water-adsorption hydrogels was successfully preparation by radiation crosslinking CMC in paste condition and radiation grafting acrylic acid into starch. The hydrogel with 76.36% gel fraction and 91.13% swelling degree were obtained by irradiation of CMC 20% at 20 kGy, while the hydrogel with 65.3% gel fraction and 234 swelling degree was acrylic acid and starch at 4 kGy. The supplementation of hydrogels prepared by radiation technique showed a higher cellulose degradation effect of waste of cattle after fermenting 30 and 45 days. The optimum condition was determined by mixing 1% (w/w) dried hydrogel in 99% (w/w) waste of cattle. The fermented sawdust using hydrogel prepared by radiation technique showed a better effect on the growth of F1 Chinese cabbage (Brassica Pe-tsai Bailey L.). (author)

  17. Assessment of Haar Wavelet-Quasilinearization Technique in Heat Convection-Radiation Equations

    Directory of Open Access Journals (Sweden)

    Umer Saeed

    2014-01-01

    Full Text Available We showed that solutions by the Haar wavelet-quasilinearization technique for the two problems, namely, (i temperature distribution equation in lumped system of combined convection-radiation in a slab made of materials with variable thermal conductivity and (ii cooling of a lumped system by combined convection and radiation are strongly reliable and also more accurate than the other numerical methods and are in good agreement with exact solution. According to the Haar wavelet-quasilinearization technique, we convert the nonlinear heat transfer equation to linear discretized equation with the help of quasilinearization technique and apply the Haar wavelet method at each iteration of quasilinearization technique to get the solution. The main aim of present work is to show the reliability of the Haar wavelet-quasilinearization technique for heat transfer equations.

  18. The method validation step of biological dosimetry accreditation process

    International Nuclear Information System (INIS)

    Roy, L.; Voisin, P.A.; Guillou, A.C.; Busset, A.; Gregoire, E.; Buard, V.; Delbos, M.; Voisin, Ph.

    2006-01-01

    One of the missions of the Laboratory of Biological Dosimetry (L.D.B.) of the Institute for Radiation and Nuclear Safety (I.R.S.N.) is to assess the radiological dose after an accidental overexposure suspicion to ionising radiation, by using radio-induced changes of some biological parameters. The 'gold standard' is the yield of dicentrics observed in patients lymphocytes, and this yield is converted in dose using dose effect relationships. This method is complementary to clinical and physical dosimetry, for medical team in charge of the patients. To obtain a formal recognition of its operational activity, the laboratory decided three years ago, to require an accreditation, by following the recommendations of both 17025 General Requirements for the Competence of Testing and Calibration Laboratories and 19238 Performance criteria for service laboratories performing biological dosimetry by cyto-genetics. Diagnostics, risks analysis were realized to control the whole analysis process leading to documents writing. Purchases, personnel department, vocational training were also included in the quality system. Audits were very helpful to improve the quality system. One specificity of this technique is that it is not normalized therefore apart from quality management aspects, several technical points needed some validations. An inventory of potentially influent factors was carried out. To estimate their real effect on the yield of dicentrics, a Placket-Burman experimental design was conducted. The effect of seven parameters was tested: the BUdr (bromodeoxyuridine), PHA (phytohemagglutinin) and colcemid concentration, the culture duration, the incubator temperature, the blood volume and the medium volume. The chosen values were calculated according to the uncertainties on the way they were measured i.e. pipettes, thermometers, test tubes. None of the factors has a significant impact on the yield of dicentrics. Therefore the uncertainty linked to their use was considered as

  19. The method validation step of biological dosimetry accreditation process

    Energy Technology Data Exchange (ETDEWEB)

    Roy, L.; Voisin, P.A.; Guillou, A.C.; Busset, A.; Gregoire, E.; Buard, V.; Delbos, M.; Voisin, Ph. [Institut de Radioprotection et de Surete Nucleaire, LDB, 92 - Fontenay aux Roses (France)

    2006-07-01

    One of the missions of the Laboratory of Biological Dosimetry (L.D.B.) of the Institute for Radiation and Nuclear Safety (I.R.S.N.) is to assess the radiological dose after an accidental overexposure suspicion to ionising radiation, by using radio-induced changes of some biological parameters. The 'gold standard' is the yield of dicentrics observed in patients lymphocytes, and this yield is converted in dose using dose effect relationships. This method is complementary to clinical and physical dosimetry, for medical team in charge of the patients. To obtain a formal recognition of its operational activity, the laboratory decided three years ago, to require an accreditation, by following the recommendations of both 17025 General Requirements for the Competence of Testing and Calibration Laboratories and 19238 Performance criteria for service laboratories performing biological dosimetry by cyto-genetics. Diagnostics, risks analysis were realized to control the whole analysis process leading to documents writing. Purchases, personnel department, vocational training were also included in the quality system. Audits were very helpful to improve the quality system. One specificity of this technique is that it is not normalized therefore apart from quality management aspects, several technical points needed some validations. An inventory of potentially influent factors was carried out. To estimate their real effect on the yield of dicentrics, a Placket-Burman experimental design was conducted. The effect of seven parameters was tested: the BUdr (bromodeoxyuridine), PHA (phytohemagglutinin) and colcemid concentration, the culture duration, the incubator temperature, the blood volume and the medium volume. The chosen values were calculated according to the uncertainties on the way they were measured i.e. pipettes, thermometers, test tubes. None of the factors has a significant impact on the yield of dicentrics. Therefore the uncertainty linked to their use was

  20. Handling technique of spore-forming bacteria in radiation sterilization. 1. Preparation of spores

    International Nuclear Information System (INIS)

    Koshikawa, Tomihiko

    1994-01-01

    This paper deals with a handling technique of spore-forming bacteria in radiation sterilization. An explanation is given under three sections: (1) life cycle of spore-forming bacteria, medium to form bacterial spores, and colony and purification methods of bacterial spores; (2) methods for measuring the number of bacterial spores and resistance against gamma radiation (D values); and (3) a test method for identifying spore-forming bacteria and a simple identification method. (N.K.)

  1. Image quality and radiation exposure in digital storage plate mammography with magnification technique

    International Nuclear Information System (INIS)

    Fiedler, E.; Aichinger, U.; Boehner, C.; Schulz-Wendtland, R.; Bautz, W.; Saebel, M.

    1999-01-01

    Purpose: Comparison of image quality between digital phosphor storage plate mammography in magnification technique and a conventional film screen system regarding the special aspect of radiation exposure. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system and two digital storage plate systems. Additionally, the radiograms of one digital system were postprocessed emphasizing contrast and included in the comparison. Results: The detectability of details in storage plate mammographies with magnification technique is almost equal to that of film screen mammographies. Thereby, lower radiation exposures were necessary using the digital systems. Conclusions: Based on these results, storage plate mammography in magnification technique is used in clinical routine at our institution. The correct parameters in image postprocessing are of elementary importance for detail detectability. Future studies must show, whether the lower radiation exposure in digital radiograms of the breast, revealing much higher background noise, will allow the same detail detectability as film screen mammographies. (orig.) [de

  2. Application of virtual reality technique to a radiation protection training program

    International Nuclear Information System (INIS)

    Hajek, Brian K.; Kang, Ki Doo; Shin, Yoo Jin; Lee, Yon Sik

    2003-01-01

    Using an Internet Virtual Reality (IVR) technique, a 3-dimensional (3-D) model for the radiation controlled area in a nuclear power plant was developed, and a feasibility study to develop a computational program to estimate radiation dose was performed. For this purpose, a pilot model with a dynamic function and bi-directional communication was developed. This model was enhanced from the existing 3-D single-directional communication. In this pilot model, a plant visitor needs to first pass a series of security checks. If the visitor enters the controlled area and approaches a radiation hazard area, alarms with a warning lamp will be initiated automatically. Throughout the test to connect this model from both domestic and international sites in various time zones, it has proven to perform well. Therefore, this model can be applied to broad fields as radiation protection procedures or radiation protection training with photographic data, and on-line dose assessment programs

  3. Development of radiation-induced mutation techniques and functional genomics studies

    International Nuclear Information System (INIS)

    Kim, Dong Sub; Kang, Si Yong; Kim, Jin Baek

    2012-01-01

    This project has been performed to develop plant genetic resources using radiation (gamma-rays, ion-beam, space environments), to conduct functional genomics studies with mutant resources, and to develop new radiation plant breeding techniques using various radiation sources during 3 years. In the first section, we developed flower genetic resources, functional crop resources, and bio-industrial plant resources. In the second section, we cloned several mutated genes and studied mechanisms of gene expression and genetic diversity of mutations induced by gamma-rays. In the third section, we developed new plant breeding techniques using gamma-phytotron, heavy ion-beam, and space environments. Based on these results, a total of 8 cultivars containing Chrysanthemum, Hibiscus, kenaf, rice, and soybean were applied for plant variety protection (PVP) and a total of 4 cultivars were registered for PVP. Also, license agreement for the dwarf type Hibiscus mutant 'Ggoma' was conducted with Supro co. and the manufacturing technology for natural antioxidant pear-grape vinegar was transferred into Enzenic co. Also, 8 gene sequences, such as F3'H and LDOX genes associated with flower color in Chrysanthemum and EPSPS gene from Korean lawn grass, were registered in the database of National Center for Biotechnology Information (NCBI). In the future study, we will develop new radiation mutation breeding techniques through the mutation spectrum induced by various radiation sources, the studies for mechanism of the cellular response to radiation, and the comparative·structural·functional genomics studies for useful traits

  4. Radiation hardening techniques for rare-earth based optical fibers and amplifiers

    International Nuclear Information System (INIS)

    Girard, Sylvain; Marcandella, Claude; Vivona, Marilena; Prudenzano, Luciano Mescia F.; Laurent, Arnaud; Robin, Thierry; Cadier, Benoit; Pinsard, Emmanuel; Ouerdane, Youcef; Boukenter, Aziz; Cannas, Marco; Boscaino, Roberto

    2012-01-01

    Er/Yb doped fibers and amplifiers have been shown to be very radiation sensitive, limiting their integration in space. We present an approach including successive hardening techniques to enhance their radiation tolerance. The efficiency of our approach is demonstrated by comparing the radiation responses of optical amplifiers made with same lengths of different rare-earth doped fibers and exposed to gamma-rays. Previous studies indicated that such amplifiers suffered significant degradation for doses exceeding 10 krad. Applying our techniques significantly enhances the amplifier radiation resistance, resulting in a very limited degradation up to 50 krad. Our optimization techniques concern the fiber composition, some possible pre-treatments and the interest of simulation tools used to harden by design the amplifiers. We showed that adding cerium inside the fiber phospho-silicate-based core strongly decreases the fiber radiation sensitivity compared to the standard fiber. For both fibers, a pre-treatment with hydrogen permits to enhance again the fiber resistance. Furthermore, simulations tools can also be used to improve the tolerance of the fiber amplifier by helping identifying the best amplifier configuration for operation in the radiative environment. (authors)

  5. How changing quality management influenced PGME accreditation: a focus on decentralization and quality improvement.

    Science.gov (United States)

    Akdemir, Nesibe; Lombarts, Kiki M J M H; Paternotte, Emma; Schreuder, Bas; Scheele, Fedde

    2017-06-02

    Evaluating the quality of postgraduate medical education (PGME) programs through accreditation is common practice worldwide. Accreditation is shaped by educational quality and quality management. An appropriate accreditation design is important, as it may drive improvements in training. Moreover, accreditors determine whether a PGME program passes the assessment, which may have major consequences, such as starting, continuing or discontinuing PGME. However, there is limited evidence for the benefits of different choices in accreditation design. Therefore, this study aims to explain how changing views on educational quality and quality management have impacted the design of the PGME accreditation system in the Netherlands. To determine the historical development of the Dutch PGME accreditation system, we conducted a document analysis of accreditation documents spanning the past 50 years and a vision document outlining the future system. A template analysis technique was used to identify the main elements of the system. Four themes in the Dutch PGME accreditation system were identified: (1) objectives of accreditation, (2) PGME quality domains, (3) quality management approaches and (4) actors' responsibilities. Major shifts have taken place regarding decentralization, residency performance and physician practice outcomes, and quality improvement. Decentralization of the responsibilities of the accreditor was absent in 1966, but this has been slowly changing since 1999. In the future system, there will be nearly a maximum degree of decentralization. A focus on outcomes and quality improvement has been introduced in the current system. The number of formal documents striving for quality assurance has increased enormously over the past 50 years, which has led to increased bureaucracy. The future system needs to decrease the number of standards to focus on measurable outcomes and to strive for quality improvement. The challenge for accreditors is to find the right

  6. Accreditation in general practice in Denmark

    DEFF Research Database (Denmark)

    Andersen, Merethe K; Pedersen, Line B; Siersma, Volkert

    2017-01-01

    Background: Accreditation is used increasingly in health systems worldwide. However, there is a lack of evidence on the effects of accreditation, particularly in general practice. In 2016 a mandatory accreditation scheme was initiated in Denmark, and during a 3-year period all practices, as default...... general practitioners in Denmark. Practices allocated to accreditation in 2016 serve as the intervention group, and practices allocated to accreditation in 2018 serve as controls. The selected outcomes should meet the following criteria: (1) a high degree of clinical relevance; (2) the possibility...... practice and mortality. All outcomes relate to quality indicators included in the Danish Healthcare Quality Program, which is based on general principles for accreditation. Discussion: The consequences of accreditation and standard-setting processes are generally under-researched, particularly in general...

  7. [ISO 15189 medical laboratory accreditation].

    Science.gov (United States)

    Aoyagi, Tsutomu

    2004-10-01

    This International Standard, based upon ISO/IEC 17025 and ISO 9001, provides requirements for competence and quality that are particular to medical laboratories. While this International Standard is intended for use throughout the currently recognized disciplines of medical laboratory services, those working in other services and disciplines will also find it useful and appropriate. In addition, bodies engaged in the recognition of the competence of medical laboratories will be able to use this International Standard as the basis for their activities. The Japan Accreditation Board for Conformity Assessment (AB) and the Japanese Committee for Clinical Laboratory Standards (CCLS) are jointly developing the program of accreditation of medical laboratories. ISO 15189 requirements consist of two parts, one is management requirements and the other is technical requirements. The former includes the requirements of all parts of ISO 9001, moreover it includes the requirement of conformity assessment body, for example, impartiality and independence from any other party. The latter includes the requirements of laboratory competence (e.g. personnel, facility, instrument, and examination methods), moreover it requires that laboratories shall participate proficiency testing(s) and laboratories' examination results shall have traceability of measurements and implement uncertainty of measurement. Implementation of ISO 15189 will result in a significant improvement in medical laboratories management system and their technical competence. The accreditation of medical laboratory will improve medical laboratory service and be useful for patients.

  8. Utilization of a photon transport code to investigate radiation therapy treatment planning quantities and techniques

    International Nuclear Information System (INIS)

    Palta, J.R.

    1981-01-01

    A versatile computer program MORSE, based on neutron and photon transport theory has been utilzed to investigate radiation therapy treatment planning quantities and techniques. A multi-energy group representation of transport equation provides a concise approach in utilizing Monte Carlo numerical techniques to multiple radiation therapy treatment planning problems. Central axis total and scattered dose distributions for homogeneous and inhomogeneous water phantoms are calculated and the correction factor for lung and bone inhomogeneities are also evaluated. Results show that Monte Carlo calculations based on multi-energy group tansport theory predict the depth dose distributions that are in good agreement with available experimental data. Central axis depth dose distributions for a bremsstrahlung spectrum from a linear accelerator is also calculated to exhibit the versatility of the computer program in handling multiple radiation therapy problems. A novel approach is undertaken to study the dosimetric properties of brachytherapy sources

  9. Measurements of diversity gain and radiation efficiency of the eleven antenna by using different measurement techniques

    DEFF Research Database (Denmark)

    Yang, Jian; Pivnenko, Sergey; Laitinen, Tommi

    2010-01-01

    This paper presents measurement results of diversity gain and radiation efficiency by using three different measurement techniques: reverberation chamber, spherical near-field anechoic chamber, and multi-probe anechoic chamber. The results are measured over a large 2–8 GHz bandwidth which...

  10. AN IMAGE-ANALYSIS TECHNIQUE FOR DETECTION OF RADIATION-INDUCED DNA FRAGMENTATION AFTER CHEF ELECTROPHORESIS

    NARCIS (Netherlands)

    ROSEMANN, M; KANON, B; KONINGS, AWT; KAMPINGA, HH

    CHEF-electrophoresis was used as a technique to detect radiation-induced DNA breakage with special emphasis to biological relevant X-ray doses (0-10 Gy). Fluorescence detection of DNA-fragments using a sensitive image analysis system was directly compared with conventional scintillation counting of

  11. Hospital accreditation: staff experiences and perceptions.

    Science.gov (United States)

    Bogh, Søren Bie; Blom, Ane; Raben, Ditte Caroline; Braithwaite, Jeffrey; Thude, Bettina; Hollnagel, Erik; Plessen, Christian von

    2018-06-11

    Purpose The purpose of this paper is to understand how staff at various levels perceive and understand hospital accreditation generally and in relation to quality improvement (QI) specifically. Design/methodology/approach In a newly accredited Danish hospital, the authors conducted semi-structured interviews to capture broad ranging experiences. Medical doctors, nurses, a quality coordinator and a quality department employee participated. Interviews were audio recorded and subjected to framework analysis. Findings Staff reported that The Danish Healthcare Quality Programme affected management priorities: office time and working on documentation, which reduced time with patients and on improvement activities. Organisational structures were improved during preparation for accreditation. Staff perceived that the hospital was better prepared for new QI initiatives after accreditation; staff found disease specific requirements unnecessary. Other areas benefited from accreditation. Interviewees expected that organisational changes, owing to accreditation, would be sustained and that the QI focus would continue. Practical implications Accreditation is a critical and complete hospital review, including areas that often are neglected. Accreditation dominates hospital agendas during preparation and surveyor visits, potentially reducing patient care and other QI initiatives. Improvements are less likely to occur in areas that other QI initiatives addressed. Yet, accreditation creates organisational foundations for future QI initiatives. Originality/value The authors study contributes new insights into how hospital staff at different organisational levels perceive and understand accreditation.

  12. Systematization of types and methods of radiation therapy methods and techniques of irradiation of patients

    International Nuclear Information System (INIS)

    Vajnberg, M.Sh.

    1991-01-01

    The paper is concerned with the principles of systematization and classification of types and methods of radiation therapy, approaches to the regulation of its terminology. They are based on the distinction of the concepts of radiation therapy and irradiation of patients. The author gives a consice historical review of improvement of the methodology of radiation therapy in the course of developing of its methods and facilities. Problems of terminology are under discussion. There is a table of types and methods of radiation therapy, methods and techniques of irradiation. In the appendices one can find a table of typical legends and examples of graphic signs to denote methods of irradiation. Potentialities of a practical use of the system are described

  13. Development of new production technique using radiation for new crops and spreading of the crops

    International Nuclear Information System (INIS)

    Miyahara, Kenzo; Nishio, Takeshi; Yoshioka, Toji

    1997-01-01

    Investigation has been made on the technique for effective induction of useful mutant crops by making use of soft X-ray (50 Gy) radiation. In this study, the effects of soft X-ray were examined on the germination, growth and fertility of Koshihikari, a rice variety and compared with those of γ-ray. The survival rate decreased dose-dependently in either condition of tube voltage of 20, 60 or 100 kVp. The LD 50 of soft X-ray was significantly higher at all voltages than γ-ray at 250 Gy. And the fertility was lowered by soft X-ray radiation. Either of the radiation effects were marked when the rice subjects were exposed in the direction coincident with the radiation source. These results suggest that higher dose is needed for mutant induction by soft X-ray radiation than by γ-ray. Next, the mutant production induced by γ-ray radiation and their characteristics were investigated in Japanese pear varieties. Four moderately and 2 highly resistant varieties against black rot disease were selected by pulse and long radiation of γ-ray. These 6 varieties were significantly stronger than the parent pear, but not completely resistant against the disease. (M.N.)

  14. Assessing a new gene expression analysis technique for radiation biodosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Manning, Grainne; Kabacik, Sylwia; Finnon, Paul; Paillier, Francois; Bouffler, Simon [Cancer Genetics and Cytogenetics, Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom); Badie, Christophe, E-mail: christophe.badie@hpa.org.uk [Cancer Genetics and Cytogenetics, Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom)

    2011-09-15

    The response to any radiation accident or incident involving actual or potential ionising radiation exposure requires accurate and rapid assessment of the doses received by individuals. The techniques available today for biodosimetry purposes are not fully adapted to rapid high-throughput measurements of exposures in large numbers of individuals. A recently emerging technique is based on gene expression analysis, as there are a number of genes which are radiation responsive in a dose-dependent manner. The present work aimed to assess a new technique which allows the detection of the level of expression of up to 800 genes without need of enzymatic reactions. In order to do so, human peripheral blood was exposed ex vivo to a range of x-ray doses from 5 mGy to 4 Gy of x-rays and the transcriptional expression of five radiation-responsive genes PHPT1, PUMA, CCNG1, DDB2 and MDM2 was studied by both the nCounter Digital Analyzer and Multiplex Quantitative Real-Time Polymerase Chain Reaction (MQRT-PCR) as the benchmark technology. Results from both techniques showed good correlation for all genes with R{sup 2} values ranging between 0.8160 and 0.9754. The reproducibility of the nCounter Digital Analyzer was also assessed in independent biological replicates and proved to be good. Although the slopes of the correlation of results obtained by the techniques suggest that MQRT-PCR is more sensitive than the nCounter Digital Analyzer, the nCounter Digital Analyzer provides sensitive and reliable data on modifications in gene expression in human blood exposed to radiation without enzymatic amplification of RNA prior to analysis.

  15. Detection of radiation deformation in crystalline polymers using the speckle photography technique

    International Nuclear Information System (INIS)

    El-Ghandoor, H.; Hashem, A.A.; Sharaf, F.

    1995-01-01

    In order to measure the resulting deformation due to gamma irradiation of polymers, a new optical technique, namely speckle-photography, was established and used. Thin films of tetrafluoroethene, with constant thickness were irradiated by different doses of gamma rays and the diffraction patterns of a laser beam passing through these films were recorded using the speckle photography technique. This technique has been applied to detect the radiation deformation in (Teflon) TFE, which is a crystalline polymer. A diffraction pattern due to the TFE thin layer is obtained and superimposed on the interference pattern displaying the speckle pattern pairs recorded on the same emulsion. (author)

  16. Applications of advanced electron microscopy techniques to the studies of radiation effects in ceramic materials

    International Nuclear Information System (INIS)

    Wang, L.M.

    1998-01-01

    This paper summarizes some recent results from the application of several advanced transmission electron microscopy (TEM) techniques to the studies of radiation effects in insulators with the main focus on radiation-induced amorphization. These techniques include in situ TEM during ion-beam irradiation at cryogenic and elevated temperatures, cross-sectional TEM, high-resolution TEM, and image simulation on partially damaged materials, as well as digital TEM with image processing and analysis. The combination of these techniques may often provide very detailed information about the microstructure evolution during energetic particle irradiation, especially at the early stages, which is unobtainable with any other analytical methods. These techniques have been successfully applied to the analysis of a large group of ion-beam-irradiated ceramics, including quartz, silicon carbides, uranium oxide, apatite, spinel and other complex mineral phases. The advantages and limitations of each technique, as well as some important technical details for the analysis of radiation damage in ceramics are presented. (orig.)

  17. Monte Carlo technique applications in field of radiation dosimetry at ENEA radiation protection institute: A Review

    International Nuclear Information System (INIS)

    Gualdrini, G.F.; Casalini, L.; Morelli, B.

    1994-12-01

    The present report summarizes the activities concerned with numerical dosimetry as carried out at the Radiation Protection Institute of ENEA (Italian Agency for New Technologies, Energy and the Environment) on photon dosimetric quantities. The first part is concerned with MCNP Monte Carlo calculation of field parameters and operational quantities for the ICRU sphere with reference photon beams for the design of personal dosemeters. The second part is related with studies on the ADAM anthropomorphic phantom using the SABRINA and MCNP codes. The results of other Monte Carlo studies carried out on electron conversion factors for various tissue equivalent slab phantoms are about to be published in other ENEA reports. The report has been produced in the framework of the EURADOS WG4 (numerical dosimetry) activities within a collaboration between the ENEA Environmental Department and ENEA Energy Department

  18. Dose measurement techniques for high-energy photon and electron radiation

    International Nuclear Information System (INIS)

    Hohlfeld, K.; Roos, M.

    1992-08-01

    By law the Federal Institute of Physics and Technology (PTB) has been assigned the tasks of representing, preserving and passing on dose units. The analogous continuation of these tasks consists in improving, at the user level, dosimetry techniques in radiation therapy for the benefit of patients. The PTB had an essential share in working out the scientific foundations of dosimetry for high-energy radiation, and the corresponding DIN standards were established with the PTB playing a prominent part. The seminar aimed at presenting the measuring techniques fixed in the new DIN standard 6800 part 2 'Dose measurement techniques according to the probe method - ionization dosimetry', to discuss their physical background and practical implications resulting from them. (orig.) [de

  19. Microhardness technique for determination of radiation hardening in austenitic stainless steel using

    International Nuclear Information System (INIS)

    Hofman, A.

    1995-01-01

    The use of microhardness technique to determine the radiation hardening has been studied. Microhardness measurements have been conducted on austenitic stainless steel 0H18N10T irradiated up to 2·10 23 nm -2 . It was determined that the increase in microhardness varies directly with the measured increase in the 0,2% offret yield strength and has been found that microhardness technique may be an effective tool to measurements of radiation induced hardening. Based on the results and Cahoon's relation that σ 0,2 (MPa)=3,27HV(0,1) n method for evaluating the yield stress σ 0,2 by microhardness technique is analyzed. 14 refs., 3 figs., 3 tabs

  20. Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Shu Deming

    2010-01-01

    At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

  1. Requirements for radiation emergency urine bioassay techniques for the public and first responders.

    Science.gov (United States)

    Li, Chunsheng; Vlahovich, Slavica; Dai, Xiongxin; Richardson, Richard B; Daka, Joseph N; Kramer, Gary H

    2010-11-01

    Following a radiation emergency, the affected public and the first responders may need to be quickly assessed for internal contamination by the radionuclides involved. Urine bioassay is one of the most commonly used methods for assessing radionuclide intake and radiation dose. This paper attempts to derive the sensitivity requirements (from inhalation exposure) for the urine bioassay techniques for the top 10 high-risk radionuclides that might be used in a terrorist attack. The requirements are based on a proposed reference dose to adults of 0.1 Sv (CED, committed effective dose). In addition, requirements related to sample turnaround time and field deployability of the assay techniques are also discussed. A review of currently available assay techniques summarized in this paper reveals that method development for ²⁴¹Am, ²²⁶Ra, ²³⁸Pu, and ⁹⁰Sr urine bioassay is needed.

  2. The importance of the chosen technique to estimate diffuse solar radiation by means of regression

    Energy Technology Data Exchange (ETDEWEB)

    Arslan, Talha; Altyn Yavuz, Arzu [Department of Statistics. Science and Literature Faculty. Eskisehir Osmangazi University (Turkey)], email: mtarslan@ogu.edu.tr, email: aaltin@ogu.edu.tr; Acikkalp, Emin [Department of Mechanical and Manufacturing Engineering. Engineering Faculty. Bilecik University (Turkey)], email: acikkalp@gmail.com

    2011-07-01

    The Ordinary Least Squares (OLS) method is one of the most frequently used for estimation of diffuse solar radiation. The data set must provide certain assumptions for the OLS method to work. The most important is that the regression equation offered by OLS error terms must fit within the normal distribution. Utilizing an alternative robust estimator to get parameter estimations is highly effective in solving problems where there is a lack of normal distribution due to the presence of outliers or some other factor. The purpose of this study is to investigate the value of the chosen technique for the estimation of diffuse radiation. This study described alternative robust methods frequently used in applications and compared them with the OLS method. Making a comparison of the data set analysis of the OLS and that of the M Regression (Huber, Andrews and Tukey) techniques, it was study found that robust regression techniques are preferable to OLS because of the smoother explanation values.

  3. A new sensitive technique for study of radiation effects in amino acids

    International Nuclear Information System (INIS)

    Thwaites, D.I.; Buchan, G.; Ettinger, K.V.; Mallard, J.R.; Takavar, A.

    1976-01-01

    A new technique for the study of radiation induced free radicals in amino acids based on their reactions when untrapped by dissolution in water is reported. The light emission or lyoluminescence response of various amino acids to gamma radiation ( 60 Co) measured 4 hr after irradiation are shown. The sensitivities vary over three orders of magnitude, but there is little or no correlation between the lyoluminescent response and the structural type of amino acid. Dose-reponse curves indicate that the useful range extends from a few krad to a few hundred krad. Methods of extending the lower limits are discussed. Storage of irradiated material over a period of 4 months at 20 0 C showed changes of the order of 10%. Exposure to daylight has no effect on the light yield of amino acids. It is stated that the lyoluminescence technique is more sensitive than ESR in detecting radiation effects in amino acids. Lyoluminescence of irradiated proteins, RNA and DNA, has been observed. It appears that the new method may be particularly useful in providing information on the nature and magnitude of direct radiation damage in biologically important compounds and find applications in radiation dosimetry. (U.K.)

  4. Applications Of Monte Carlo Radiation Transport Simulation Techniques For Predicting Single Event Effects In Microelectronics

    International Nuclear Information System (INIS)

    Warren, Kevin; Reed, Robert; Weller, Robert; Mendenhall, Marcus; Sierawski, Brian; Schrimpf, Ronald

    2011-01-01

    MRED (Monte Carlo Radiative Energy Deposition) is Vanderbilt University's Geant4 application for simulating radiation events in semiconductors. Geant4 is comprised of the best available computational physics models for the transport of radiation through matter. In addition to basic radiation transport physics contained in the Geant4 core, MRED has the capability to track energy loss in tetrahedral geometric objects, includes a cross section biasing and track weighting technique for variance reduction, and additional features relevant to semiconductor device applications. The crucial element of predicting Single Event Upset (SEU) parameters using radiation transport software is the creation of a dosimetry model that accurately approximates the net collected charge at transistor contacts as a function of deposited energy. The dosimetry technique described here is the multiple sensitive volume (MSV) model. It is shown to be a reasonable approximation of the charge collection process and its parameters can be calibrated to experimental measurements of SEU cross sections. The MSV model, within the framework of MRED, is examined for heavy ion and high-energy proton SEU measurements of a static random access memory.

  5. Accreditation ISO/IEC 1705 in dosimetry: Experience and results; Acreditacion ISO/IEC 17025 en dosimetria: Experiencia y resultados

    Energy Technology Data Exchange (ETDEWEB)

    Martin Garcia, R.; Navarro Bravo, T.

    2013-07-01

    The objective of this work is to present the experience in the process of accreditation of the radiation dosimetry service in which there are trials for the determination of radiation doses due to internal and external exhibitions. Is They describe the aspects that were considered for the design and development of a system of quality and results after its implementation. A review of the benefits accreditation has been reported to the organization is finally made. (Author)

  6. Perry Johnson Laboratory Accreditation, Inc. (PJLA)

    Science.gov (United States)

    2011-03-28

    Accreditation Body, established in 1999, located in Troy, Michigan • Current Accreditation Programs– ISO / IEC 17025 :2005 and DoD ELAP, EPA NLLAP...Upcoming Accreditation Programs–Field Site Sampling & Measurement Organizations (FSMO)–TNI Volume 1 and 2, Reference Material Producers– ISO Guide...Testing/Calibration – 17025 -Testing–120 – 17025 -Calibration–191 – 17025 & DoD ELAP–14 (5 Pending) – 17025 and EPA NLLAP–1 – Pending

  7. Development of radiation-induced mutation techniques and functional genomics studies

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Sub; Kang, Si Yong; Kim, Jin Baek [KAERI, Daejeon (Korea, Republic of); and others

    2012-01-15

    This project has been performed to develop plant genetic resources using radiation (gamma-rays, ion-beam, space environments), to conduct functional genomics studies with mutant resources, and to develop new radiation plant breeding techniques using various radiation sources during 3 years. In the first section, we developed flower genetic resources, functional crop resources, and bio-industrial plant resources. In the second section, we cloned several mutated genes and studied mechanisms of gene expression and genetic diversity of mutations induced by gamma-rays. In the third section, we developed new plant breeding techniques using gamma-phytotron, heavy ion-beam, and space environments. Based on these results, a total of 8 cultivars containing Chrysanthemum, Hibiscus, kenaf, rice, and soybean were applied for plant variety protection (PVP) and a total of 4 cultivars were registered for PVP. Also, license agreement for the dwarf type Hibiscus mutant 'Ggoma' was conducted with Supro co. and the manufacturing technology for natural antioxidant pear-grape vinegar was transferred into Enzenic co. Also, 8 gene sequences, such as F3'H and LDOX genes associated with flower color in Chrysanthemum and EPSPS gene from Korean lawn grass, were registered in the database of National Center for Biotechnology Information (NCBI). In the future study, we will develop new radiation mutation breeding techniques through the mutation spectrum induced by various radiation sources, the studies for mechanism of the cellular response to radiation, and the comparative{center_dot}structural{center_dot}functional genomics studies for useful traits.

  8. Radiation therapy for retinoblastoma: comparison of results with lens-sparing versus lateral beam techniques

    International Nuclear Information System (INIS)

    McCormick, B.; Ellsworth, R.; Abramson, D.; Haik, B.; Tome, M.; Grabowski, E.; LoSasso, T.

    1988-01-01

    From 1979 through 1986, 170 children were seen at our institution diagnosed with retinoblastoma. Sixty-six of the children with involvement of 121 eyes, were referred for definitive external beam radiation to one or both eyes. During the study period, two distinct radiation techniques were used. From 1980 through mid-1984, a lens-sparing technique included an anterior electron beam with a contact lens mounted lead shield, combined with a lateral field, was used. Since mid-1984, a modified lateral beam technique has been used, mixing lateral electrons and superior and inferior lateral oblique split beam wedged photons. Doses prescribed were similar for both techniques, ranging from 3,850 to 5,000 cGy in 4 to 5 weeks. The lens-sparing and the modified lateral techniques are compared for local control. For eyes with Group I through III disease, the lens-sparing technique resulted in local control in 33% of the eyes treated, where the modified lateral technique controlled 83% of the eyes treated (p = .006). Mean time to relapse was identical in both groups, that is 24 and 26 months respectively. Most relapses were successfully treated with further local therapy, including laser or cryosurgery, or 60Co plaques. Five eyes required enucleation following initial treatment with the lens-sparing technique, but none thus far with the lateral beam technique. For eyes with Group IV and V disease, no significant differences were found between the two techniques in terms of local control or eventual need for enucleation. With a mean follow-up time of 33 months for the entire group, the 4-year survival is 93%. Two of the 4 deaths are due to second primary tumor, and all 4 have occurred in the lens-sparing group. Because follow-up time is more limited in the lateral beam group, this is not statistically significant and direct survival comparisons are premature

  9. The study of preparation for immobilized cells membranes of E. Coli. by radiation technique

    International Nuclear Information System (INIS)

    Cao Jin; Chen Pin; Yu Yi

    1991-01-01

    The paper described the preparation of immobilized cells membranes with E. Coli by radiation technique. The nylon 6 was grafted with HEMA, which as a matrix to prepare immobilized cells membranes with E. Coli. by radiation entrapment at low temperature. The results showed that the retentive activity possessed a maximum value for membranes with E. Coli. when the irradiation dose was at 10-12 kGy, the entrapped cells has 2.3 g/ml at 50% HEMA concentration, the optimum pH and optimum temperature for membranes with E. Coli. are as same the original cells

  10. A Threat to Accreditation: Defamation Judgment against an Accreditation Team Member.

    Science.gov (United States)

    Flygare, Thomas J.

    1980-01-01

    Delaware Law School founder Alfred Avins successfully sued accreditation team member James White for defamation as a result of comments made in 1974 and 1975. An appeals brief claims Avins was a "public figure," that he consented to accreditation, and that the accreditation process deserves court protection against such suits. (PGD)

  11. Surviving Accreditation: A QIAS Ideas Bank. Accreditation and Beyond Series, Volume I.

    Science.gov (United States)

    Ferry, Jan

    This publication provides information on the accreditation process for early childhood education and care providers participating in the Quality Improvement and Accreditation System (QIAS), developed by the National Childcare Accreditation Council of Australia. The publication is divided into sections corresponding to steps in the…

  12. Accreditation to manage research programs

    International Nuclear Information System (INIS)

    Miramand, Pierre

    1993-01-01

    In this report for an accreditation to supervise research, the author proposes an overview of a study of transfers of vanadium towards benthic organisms (i.e. the toxicity of vanadium for sea coastal organisms), of studies of transfer of transuranic elements from sediment to marine benthic species. He presents current researches and perspectives: study of the level of metallic pollutants and physical-chemical characteristics of coastal waters in northern Cotentin, researches in Seine Bay, study of pollution biologic indicators. Numerous articles are provided in appendix

  13. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University

  14. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  15. High-dose secondary calibration laboratory accreditation program

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1993-01-01

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program

  16. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiotherapy and Radiooncology, Muenster (Germany); Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette [University Hospital of Muenster, Department of Phoniatrics and Pediatric Audiology, Muenster (Germany)

    2017-11-15

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D{sub mean}), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D{sub mean} was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m{sup 2}, with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D{sub mean} exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [German] Analyse von Inzidenz und Schweregrad einer sensorineuralen Schwerhoerigkeit (''sensorineural hearing loss'', SNHL) infolge der Wirkung unterschiedlicher Bestrahlungstechniken, Fraktionierungen, mittlerer

  17. Novel technique for manipulating MOX fuel particles using radiation pressure of a laser light

    International Nuclear Information System (INIS)

    Omori, R.

    2000-01-01

    We have continued theoretical and experimental studies on laser manipulation of nuclear fuel particles, such as UO 2 , PuO 2 and ThO 2 , In this paper, we investigate the applicability of the collection of MOX particles floating in air using radiation pressure of a laser light; some preliminary results are shown. This technique will be useful for removal and confinement of MOX particles being transported by air current or dispersed in a cell box. First, we propose two types of principles for collecting MOX particles. Second, we show some experimental results, Third, we show numerical results of radiation pressure exerted on submicrometer-sized UO 2 particles using Generalized Lorentz-Mie theory. Because optical constants of UO 2 are similar to those of MOX fuel particles, it seems that calculation results obtained hold for MOX fuel particles. 2. Principles of collecting MOX fuel particles using radiation pressure (authors)

  18. Quality keeping and upgrading technique on delivery of raw fodder and so forth by using radiation

    International Nuclear Information System (INIS)

    Kobayashi, Ryoei; Tanaka Osamu; Uegaki, Ryuichi; Ando, Sada; Akiyama, Fumiaki; Yamada, Akio

    1999-01-01

    This study aimed at examining chemical and microbiological changes of feed raw materials caused by γ-ray radiation and obtaining some fundamental informations for development of new preparation and storage technique using radiation. In previous results, it could be estimated that the γ-ray radiation showed an effect to protect quality decrease of the silage. In particular, a product with good chemical compositions and sheep fondness and excellent quality on blended silage with pasture and beer cake could be obtained. In 1997 fiscal year, on bean curd refuse with fast putrefaction, a relationship between time length from production to closed sealing for blended silage and quality after preparation was examined. (G.K.)

  19. Progress in radiation protection techniques for workers in the nuclear industry

    International Nuclear Information System (INIS)

    Pradel, J.; Zettwoog, P.; Rouyer, J.L.

    1982-01-01

    The increasingly stringent safety requirements of workers and the general public in the face of occupational and in particular nuclear risks call for continual improvements in radiation protection techniques. The Institute of Protection and Nuclear Safety (IPSN), especially the Technical Protection Services belonging to the Protection Department, and also the various radiation protection services of the French Atomic Energy Commission's nuclear centres and Electricite de France (EDF) are carrying out substantial research and development programmes on the subject. For this reason, IPSN organized a specialists' meeting to take stock of the efforts being made and to try to identify what steps seem most promising or should have priority at the national level. The authors summarize the presentations and discussions on three topics: (1) Progress in the analysis of the mechanism of exposure of workers; (2) Progress achieved from the radiation protection standpoint in the field of facility design and instrumentation; and (3) Application of the optimization principle

  20. Preparation of nanoparticles from acrylated palm oil microemulsion using radiation technique

    International Nuclear Information System (INIS)

    Rida Tajau; Wan Mohd Zin Wan Yunus; Khairul Zaman Mohd Dahlan; Mohd Hilmi Mahmood; Kamaruddin Hashim; Mohd Yusof Hamzah

    2011-01-01

    The use of microemulsion in the development of nanoparticle based on acrylated palm oil product is demonstrated. Acrylated palm oil microemulsions were prepared using ionic surfactant. Combination methods of emulsion polymerization and radiation crosslinking were applied to the microemulsion system for synthesizing nanoparticle. The ionizing radiation technique was introduced to generate a crosslinking reaction in the development of nanoparticle. The nanoparticle was evaluated in terms of particle diameter, surface charge, pH and conductance. Their image was captured using Transmission electron microscopy (TEM). Results show that the size, charge and shape of the particles are influenced by concentration of surfactants, monomer concentration, radiation dose and time of storage. The study showed a promising method to produced nanoparticle. This nano-sized product has the potential to be utilized as controlled-drug-release-carrier. (Author)

  1. The radiation protection optimisation in contrast X-ray diagnostic techniques

    International Nuclear Information System (INIS)

    Markovic, S.; Pavlovic, R.

    1995-01-01

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit α. (author) 3 figs., 10 refs

  2. The radiation protection optimisation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit {alpha}. (author) 3 figs., 10 refs.

  3. Examination, characterisation and analysis techniques for the knowledge and the conservation / restoration of cultural heritage - importance of ionising radiation techniques

    International Nuclear Information System (INIS)

    Boutaine; J. L.

    2004-01-01

    For the examination, characterisation and analysis of cultural heritage artefacts or art objects and their component materials, the conservation scientist needs a palette of non destructive and non invasive techniques, in order to improve our knowledge concerning their elaboration, their evolution and/or degradation during time, and to give rational basis for their restoration and conservation. A general survey and illustrations showing the usefulness of these techniques will be presented. Among these methods, many are based on the use of ionising radiation. 1. Radiography (using X-rays, gamma rays, beta particles, secondary electrons, neutrons), electron emission radiography, tomodensimetry, 2. Scanning electron microscope associated with X-ray spectrometry, 3. X-ray diffraction, 4. Synchrotron radiation characterisation, 5. X-ray fluorescence analysis, 6. Activation analysis, 7. Ion beam analysis (PIXE, PIGE, RBS, secondary X-ray fluorescence), 8. Thermoluminescence dating, 9. Carbon-14 dating. These methods are used alone or in connection with other analytical methods. Any kind of materials can be encountered, for instance: i. stones, gems, ceramics, terracotta, enamels, glasses, i i. wood, paper, textile, bone, ivory, i i i. metals, jewellery, i v. paint layers, canvas and wooden backings, pigments, dyers, oils, binding media, varnishes, glues. Some examples will be taken, among recent work done at the Centre of Research and Restoration of the Museums of France (C2RMF), from various geographical origins, various ages and different art disciplines. This will illustrate the kind of assistance that science and technology can provide to a better knowledge of mankind's cultural heritage and also to the establishment of rational basis for its better conservation for the future generations. (Author)

  4. Recoil separators for radiative capture using radioactive ion beams. Recent advances and detection techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, Chris [TRIUMF, Vancouver, BC (Canada); Greife, Uwe; Hager, Ulrike [Colorado School of Mines, Golden, CO (United States)

    2014-06-15

    Radiative capture reactions involving the fusion of hydrogen or helium are ubiquitous in the stellar history of the universe, and are some of the most important reactions in the processes that govern nucleosynthesis and energy generation in both static and explosive scenarios. However, radiative capture reactions pose some of the most difficult experimental challenges due to extremely small cross sections. With the advent of recoil separators and techniques in inverse kinematics, it is now possible to measure radiative capture reactions on very short-lived radioactive nuclei, and in the presence of high experimental backgrounds. In this paper we review the experimental needs for making measurements of astrophysical importance on radiative capture reactions. We also review some of the important historical advances in the field of recoil separators as well as describe current techniques and performance milestones, including descriptions of some of the separators most recently working at radioactive ion beam facilities, such as DRAGON at TRIUMF and the DRS at the Holifield Radioactive Ion Beam Facility. We will also summarize some of the scientific highlight measurements at the RIB facilities. (orig.)

  5. Collisional-radiative switching - A powerful technique for converging non-LTE calculations

    Science.gov (United States)

    Hummer, D. G.; Voels, S. A.

    1988-01-01

    A very simple technique has been developed to converge statistical equilibrium and model atmospheric calculations in extreme non-LTE conditions when the usual iterative methods fail to converge from an LTE starting model. The proposed technique is based on a smooth transition from a collision-dominated LTE situation to the desired non-LTE conditions in which radiation dominates, at least in the most important transitions. The proposed approach was used to successfully compute stellar models with He abundances of 0.20, 0.30, and 0.50; Teff = 30,000 K, and log g = 2.9.

  6. Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner

    OpenAIRE

    Livingstone Roshan; Pradip Joe; Dinakran Paul; Srikanth B

    2010-01-01

    Objective: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. Materials and Methods: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tu...

  7. [Laboratory accreditation and proficiency testing].

    Science.gov (United States)

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  8. Consecutive cycles of hospital accreditation

    DEFF Research Database (Denmark)

    Falstie-Jensen, Anne Mette; Bogh, Søren Bie; Johnsen, Søren Paaske

    2018-01-01

    Objective: To examine the association between compliance with consecutive cycles of accreditation and patient-related outcomes. Design: A Danish nationwide population-based study from 2012 to 2015. Setting: In-patients admitted with one of the 80 diagnoses at public, non-psychiatric hospitals....... Participants: In-patients admitted with one of 80 primary diagnoses which accounted for 80% of all deaths occuring within 30 dyas after admission. Intervention: Admission to a hospital with high (n = 125 485 in-patients) or low compliance (n = 152 074 in-patients) in both cycles of accreditation by the Danish...... admission (adjusted OR: 1.26 (95% CI: 1.11-1.43) and a longer LOS (adjusted HR of discharge: 0.89 (95% CI: 0.82-0.95) than in-patients at high compliant hospitals. No difference was seen for acute readmission (adjusted HR: 0.98 (95% CI: 0.90-1.06)). Focusing on the second cycle alone, in...

  9. Library Standards: Evidence of Library Effectiveness and Accreditation.

    Science.gov (United States)

    Ebbinghouse, Carol

    1999-01-01

    Discusses accreditation standards for libraries based on experiences in an academic law library. Highlights include the accreditation process; the impact of distance education and remote technologies on accreditation; and a list of Internet sources of standards and information. (LRW)

  10. Techniques used in CAPRI for the dosimetry of γ radiations and electron beams

    International Nuclear Information System (INIS)

    Laizier, J.

    1980-01-01

    The radiation sources of CAPRI are: Pagure - 60 Co - 20Kcie, Poseidon - 60 Co - 1MCie (presently the activity is 200 Kcie), Vulcain - e - - 3MeV (variable from 0.5 MeV) - 1mA, Promethee - e - - 300 kV - 100 mA. The activities of CAPRI are research and development in industrial applications of irradiation, pilot and small scale production, irradiation (sterilization), nuclear qualification. Dosimetry techniques are: plastic dosimetry, chemical dosimetry, films [fr

  11. Radiation transport code with adaptive Mesh Refinement: acceleration techniques and applications

    International Nuclear Information System (INIS)

    Velarde, Pedro; Garcia-Fernaandez, Carlos; Portillo, David; Barbas, Alfonso

    2011-01-01

    We present a study of acceleration techniques for solving Sn radiation transport equations with Adaptive Mesh Refinement (AMR). Both DSA and TSA are considered, taking into account the influence of the interaction between different levels of the mesh structure and the order of approximation in angle. A Hybrid method is proposed in order to obtain better convergence rate and lower computer times. Some examples are presented relevant to ICF and X ray secondary sources. (author)

  12. Technique for selection of transient radiation-hard junction-isolated integrated circuits

    International Nuclear Information System (INIS)

    Crowley, J.L.; Junga, F.A.; Stultz, T.J.

    1976-01-01

    A technique is presented which demonstrates the feasibility of selecting junction-isolated integrated circuits (JI/ICS) for use in transient radiation environments. The procedure guarantees that all PNPN paths within the integrated circuit are identified and describes the methods used to determine whether the paths represent latchup susceptible structures. Two examples of the latchup analysis are given involving an SSI and an LSI bipolar junction-isolated integrated circuit

  13. Failure modes induced by natural radiation environments on DRAM memories: study, test methodology and mitigation technique

    International Nuclear Information System (INIS)

    Bougerol, A.

    2011-05-01

    DRAMs are frequently used in space and aeronautic systems. Their sensitivity to cosmic radiations have to be known in order to satisfy reliability requirements for critical applications. These evaluations are traditionally done with particle accelerators. However, devices become more complex with technology integration. Therefore new effects appear, inducing longer and more expensive tests. There is a complementary solution: the pulsed laser, which triggers similar effects as particles. Thanks to these two test tools, main DRAM radiation failure modes were studied: SEUs (Single Event Upset) in memory blocks, and SEFIs (Single Event Functional Interrupt) in peripheral circuits. This work demonstrates the influence of test patterns on SEU and SEFI sensitivities depending on technology used. In addition, this study identifies the origin of the most frequent type of SEFIs. Moreover, laser techniques were developed to quantify sensitive surfaces of the different effects. This work led to a new test methodology for industry, in order to optimize test cost and efficiency using both pulsed laser beams and particle accelerators. Finally, a new fault tolerant technique is proposed: based on DRAM cell radiation immunity when discharged, this technique allows to correct all bits of a logic word. (author)

  14. Postoperative vaginal radiation in endometrial cancer using a remote afterloading technique

    International Nuclear Information System (INIS)

    Mandell, L.; Nori, D.; Anderson, L.; Hilaris, B.

    1985-01-01

    Carcinoma of the endometrium is the most common malignancy of the female genital tract. In early stage endometrial cancer, surgery remains the primary mode of treatment while radiation therapy plays an adjuvant role. Prophylactic vaginal radiation has been shown to reduce significantly the incidence of vaginal recurrences. Between the years 1969-1976, 330 patients with FIGO Stages I and II endometrial cancer were treated according to a standard departmental policy in which 40 Gy of external radiation was given to high risk Stage I and II patients in combination with surgery and intravaginal radiation. With this regimen, the mucosal surface received a total equivalent dose of 40 Gy. These treatments were given on an outpatient basis without the need for any sedation or analgesics. The minimum follow-up was 5 years, with a median follow-up of 8.5 years. The overall pelvic and/or vaginal recurrence rate was 2.7%. The incidence of vaginal complications was 3.7%. The advantages of a remote after loading technique in delivering vaginal vault radiation in endometrial cancer are discussed

  15. Cytogenetic techniques for biological indications and dosimetry of of radiation damages in humans

    International Nuclear Information System (INIS)

    Hadjidekova, V.

    2003-01-01

    The cytogenetic methods present a proved way for bio-monitoring and bio-dosimetry for persons, submitted to ionising radiation in occupational and emergency conditions. Their application complement and assist the evaluation of the physical dosimetry and takes in account the individual radiosensitivity of the organism. A comparative assessment is made of the cytogenetic markers for radiation damage of humans applied in Bulgaria. It is discussed the sensitivity of the methods and their development in the last years, as well as the basic concept for their application - the causal relationship between the frequency of the observation of cytogenetic markers in peripheral blood lymphocytes and the risk of oncological disease. The conventional analysis of dicentrics is recognised as a 'golden standard' for the quantitative assessment of the radiation damage. The long term persisting translocations reflect properly the cumulative dose burden from chronic exposure. The micronucleus test allows a quick screening of large groups of persons, working in ionising radiation environment. The combined application with centromeric DNA probe improves the sensitivity and presents a modern alternative of the bio-monitoring and bio-dosimetry. It is discussed the advantages of the different cytogenetic techniques and their optimised application for the assessment of the radiation impact on humans

  16. Practitioner Perceptions of Advertising Education Accreditation.

    Science.gov (United States)

    Vance, Donald

    According to a 1981 survey, advertising practitioners place more importance on the accreditation of college advertising programs when it comes to evaluating a graduate of such a program than do the educators who must earn the accreditation. Only directors of advertising education programs in the communication-journalism area that are currently…

  17. 42 CFR 414.68 - Imaging accreditation.

    Science.gov (United States)

    2010-10-01

    ... relates to the past year's accreditations and trends. (viii) Attest that the organization will not perform... past year's accreditation activities and trends. (h) Continuing Federal oversight of approved... to compel by subpoena the production of witnesses, papers, or other evidence. (v) Within 45 calendar...

  18. 38 CFR 21.4253 - Accredited courses.

    Science.gov (United States)

    2010-07-01

    ... teacher's certificate or teacher's degree. (5) The course is approved by the State as meeting the... which are certified as true and correct in content and policy by an authorized representative, and the... college or university is accredited by a nationally recognized regional accrediting agency listed by the...

  19. Accreditation Association for Ambulatory Health Care

    Science.gov (United States)

    ... learn more » Study Finds Compliance Concerns Remain with Safe Injection Practices (SIP) learn more » AAAHC Updates Standards Approach ... your newborn, or something in-between, you expect safe, high-quality care. The AAAHC certificate of accreditation ... seminar Application for accreditation survey Application for Medical Home On- ...

  20. Dental radiography technique and equipment: How they influence the radiation dose received at the level of the thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Rush, E.R. [School of Health Sciences, University of Ulster, Shore Road, Newtownabbey, Belfast BT37 0QB (United Kingdom)]. E-mail: emmaroserush@hotmail.com; Thompson, N.A. [School of Health Sciences, University of Ulster, Shore Road, Newtownabbey, Belfast BT37 0QB (United Kingdom)

    2007-08-15

    Purpose: The aim of this study was to investigate the influence that collimator and technique choice had on the radiation dose detected at the thyroid gland position, during intra-oral examinations of the upper and lower teeth. Radiation dose reduction from a different perspective, other than the application of lead-rubber shielding, was addressed. Methods: A study was performed at a regional dental school with the use of a phantom head/neck and a radiation dosemeter, to measure the radiation dose detected at the thyroid gland position. The radiation dose was assessed for two intra-oral techniques (paralleling and bisecting angle), and two collimators (rectangular and circular). The radiation dose was also assessed with and without the application of a thyroid shield. Standard descriptive statistics, followed by inferential statistics were applied to the data. Results: There was a significant reduction in the radiation dose detected at the thyroid gland position, when employing the paralleling technique (66.7%) and rectangular collimator (45.5%). Other factors, for example the tooth/teeth under examination, were also found to influence the radiation dose detected. Conclusion: Radiation dose reductions using the paralleling technique and rectangular collimator were outlined. The use of this low dose combination within dental practices remains limited, therefore, continued awareness and acceptance of radiation hazards need to be addressed.

  1. Dental radiography technique and equipment: How they influence the radiation dose received at the level of the thyroid gland

    International Nuclear Information System (INIS)

    Rush, E.R.; Thompson, N.A.

    2007-01-01

    Purpose: The aim of this study was to investigate the influence that collimator and technique choice had on the radiation dose detected at the thyroid gland position, during intra-oral examinations of the upper and lower teeth. Radiation dose reduction from a different perspective, other than the application of lead-rubber shielding, was addressed. Methods: A study was performed at a regional dental school with the use of a phantom head/neck and a radiation dosemeter, to measure the radiation dose detected at the thyroid gland position. The radiation dose was assessed for two intra-oral techniques (paralleling and bisecting angle), and two collimators (rectangular and circular). The radiation dose was also assessed with and without the application of a thyroid shield. Standard descriptive statistics, followed by inferential statistics were applied to the data. Results: There was a significant reduction in the radiation dose detected at the thyroid gland position, when employing the paralleling technique (66.7%) and rectangular collimator (45.5%). Other factors, for example the tooth/teeth under examination, were also found to influence the radiation dose detected. Conclusion: Radiation dose reductions using the paralleling technique and rectangular collimator were outlined. The use of this low dose combination within dental practices remains limited, therefore, continued awareness and acceptance of radiation hazards need to be addressed

  2. Patient radiation doses in upper GI examinations: a comparison between conventional and double-contrast techniques.

    Science.gov (United States)

    Bankvall, G; Owman, T

    1982-01-01

    A total of 60 patients, divided into 3 groups with 20 patients in each, were examined with 3 different techniques: group 1 -- conventional technique, exposure at 120 kV; group 2 -- double-contrast technique (hypotonic gastrography, HG), exposure at 80 kW; group 3 -- HG, exposure at 120 kV. All examinations were performed in the same examination room and by the same radiologist. Absorbed doses to skin, thyroid, breasts, and gonads as well as energy imparted were measured. The only significant dose enhancements found when using double-contrast instead of conventional technique were in the female breasts and then only if the voltage was in the lower range. With exposure at 120 kV there was little difference in absorbed dose, but a significant advantage with respect to energy was imparted when using a double-contrast technique instead of a conventional technique. The testes doses were very low in all 3 types of examinations, and it seems that use of a testes shield is hardly motivated. With regard to both diagnostic accuracy and patient radiation dose, there can be no reason to use a conventional technique for upper GI examinations.

  3. 42 CFR Appendix B to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Hygienists

    Science.gov (United States)

    2010-10-01

    ... must include content in seven areas: radiation physics; radiation biology; radiation health, safety... 42 Public Health 1 2010-10-01 2010-10-01 false Standards for Accreditation of Dental Radiography Training for Dental Hygienists B Appendix B to Part 75 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF...

  4. 42 CFR Appendix C to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Assistants

    Science.gov (United States)

    2010-10-01

    ... areas: radiation physics; radiation biology; radiation health, safety, and protection; X-ray films and... 42 Public Health 1 2010-10-01 2010-10-01 false Standards for Accreditation of Dental Radiography Training for Dental Assistants C Appendix C to Part 75 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF...

  5. [The accreditation of professional competence: the analysis of nursinginterventions to control anxiety in surgical patients].

    Science.gov (United States)

    Brea-Rivero, Pilar; Herrera-Usagre, Manuel; Rojas-de-Mora-Figueroa, Ana; Esposito, Thomas

    2016-01-01

    . The accreditation of professional competence: the analysis of nursing interventions to control anxiety in surgical patients. The preoperative anxiety is a state of discomfort or unpleasant tension resulting from concerns about illness, hospitalization, anesthesia, surgery or the unknown. Nurses play a vital role reducing preoperative anxiety. An accreditation program was developed in Andalusia (Spain) to measure nurses' competences in this and others fields. To analyze the accredited nurses' interventions spectrum to reduce anxiety in surgical patients and to check if their range of interventions depends upon their professional skills accreditation level. Cross-sectional study. From 20016 to 2014, 1.282 interventions performed by 303 operating room nurses accredited through the Professional Skills Accreditation Program of the Andalusian Agency for Health Care Quality (ACSA) were analyzed with the latent class analysis (LCA) and multinomial logistic regression. Two-thirds of the sample was accredited in Advanced level, about 31% in Expert level and 2.6% in Excellent level. Mean age of patients was 58.5±19.8 years. Three professional profiles were obtained from the LCA. Those nurses classified in Class I (22.4% of the sample) were more likely to be women, to can for younger patients, and to be accredited in Expert or Excellent Level and to perform the larger range of interventions, becoming therefore the most complete professional profile. Those nurses who perform a wider range of interventions and specifically two evidence based interventions such Calming Technique and Coping Enhancement are those who have a higher level of accreditation level.

  6. Audit experience in external individual monitoring services accreditation in Brazil

    International Nuclear Information System (INIS)

    Martins, M.M.; Fonseca, E.S.; Pereira, W.W.; Ramos, M.M.O.; Salati, I.P.A.

    1998-01-01

    Brazilian Nuclear Energy Commission (CNEN) has been carrying out an accreditation program for the External Individual Monitoring Services (named SMIE) for about 45.000 workers involved with ionizing radiation. One of this steps of this accreditation program is the audit to each SMIE. The main audit objective is to verify and to check organizational documentation, system performance test, technical personnel ability and training, quality assurance system procedures and records, essential equipment and facilities and reliability of dose reports. In order to avoid a different audit for each SMIE, effort were made to obtain a standard process. Two aspects were considered the most relevant ones: human resources training and audit procedures. To achieve the first one, a practical and theoretical course taking into account auditing needs was elaborated. As well as experience in one of the technical related areas, an important condition to be member of an audit team is to obtain satisfactory approval in one of the offered courses. In order to accomplish the second point, a set of documents was implemented such as an audit checklist, audit report models, and procedures and recommendations to audit. Up to February 1998, 12 accreditation audits were performed. The main points of this program as well as an assessment of its difficulties and success are reported in this work

  7. A simulation technique for 3D MR-guided acoustic radiation force imaging

    International Nuclear Information System (INIS)

    Payne, Allison; Bever, Josh de; Farrer, Alexis; Coats, Brittany; Parker, Dennis L.; Christensen, Douglas A.

    2015-01-01

    Purpose: In magnetic resonance-guided focused ultrasound (MRgFUS) therapies, the in situ characterization of the focal spot location and quality is critical. MR acoustic radiation force imaging (MR-ARFI) is a technique that measures the tissue displacement caused by the radiation force exerted by the ultrasound beam. This work presents a new technique to model the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model. Methods: When a steady-state point-source force acts internally in an infinite homogeneous medium, the displacement of the material in all directions is given by the Somigliana elastostatic tensor. The radiation force field, which is caused by absorption and reflection of the incident ultrasound intensity pattern, will be spatially distributed, and the tensor formulation takes the form of a convolution of a 3D Green’s function with the force field. The dynamic accumulation of MR phase during the ultrasound pulse can be theoretically accounted for through a time-of-arrival weighting of the Green’s function. This theoretical model was evaluated experimentally in gelatin phantoms of varied stiffness (125-, 175-, and 250-bloom). The acoustic and mechanical properties of the phantoms used as parameters of the model were measured using independent techniques. Displacements at focal depths of 30- and 45-mm in the phantoms were measured by a 3D spin echo MR-ARFI segmented-EPI sequence. Results: The simulated displacements agreed with the MR-ARFI measured displacements for all bloom values and focal depths with a normalized RMS difference of 0.055 (range 0.028–0.12). The displacement magnitude decreased and the displacement pattern broadened with increased bloom value for both focal depths, as predicted by the theory. Conclusions: A new technique that models the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model theory has been rigorously validated through comparison

  8. In-room CT techniques for image-guided radiation therapy

    International Nuclear Information System (INIS)

    Ma, C.-M. Charlie; Paskalev, Kamen M.S.

    2006-01-01

    Accurate patient setup and target localization are essential to advanced radiation therapy treatment. Significant improvement has been made recently with the development of image-guided radiation therapy, in which image guidance facilitates short treatment course and high dose per fraction radiotherapy, aiming at improving tumor control and quality of life. Many imaging modalities are being investigated, including x-ray computed tomography (CT), ultrasound imaging, positron emission tomography, magnetic resonant imaging, magnetic resonant spectroscopic imaging, and kV/MV imaging with flat panel detectors. These developments provide unique imaging techniques and methods for patient setup and target localization. Some of them are different; some are complementary. This paper reviews the currently available kV x-ray CT systems used in the radiation treatment room, with a focus on the CT-on-rails systems, which are diagnostic CT scanners moving on rails installed in the treatment room. We will describe the system hardware including configurations, specifications, operation principles, and functionality. We will review software development for image fusion, structure recognition, deformation correction, target localization, and alignment. Issues related to the clinical implementation of in-room CT techniques in routine procedures are discussed, including acceptance testing and quality assurance. Clinical applications of the in-room CT systems for patient setup, target localization, and adaptive therapy are also reviewed for advanced radiotherapy treatments

  9. How Can Synchrotron Radiation Techniques Be Applied for Detecting Microstructures in Amorphous Alloys?

    Directory of Open Access Journals (Sweden)

    Gu-Qing Guo

    2015-11-01

    Full Text Available In this work, how synchrotron radiation techniques can be applied for detecting the microstructure in metallic glass (MG is studied. The unit cells are the basic structural units in crystals, though it has been suggested that the co-existence of various clusters may be the universal structural feature in MG. Therefore, it is a challenge to detect microstructures of MG even at the short-range scale by directly using synchrotron radiation techniques, such as X-ray diffraction and X-ray absorption methods. Here, a feasible scheme is developed where some state-of-the-art synchrotron radiation-based experiments can be combined with simulations to investigate the microstructure in MG. By studying a typical MG composition (Zr70Pd30, it is found that various clusters do co-exist in its microstructure, and icosahedral-like clusters are the popular structural units. This is the structural origin where there is precipitation of an icosahedral quasicrystalline phase prior to phase transformation from glass to crystal when heating Zr70Pd30 MG.

  10. Technique of radiation polymerization in fine art conservation: a potentially new method of restoration and preservation. [Uv and electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J.L. (Univ. of New South Wales, Kensington, Australia); Major, G.

    1982-01-01

    The technique of using radiation polymerization for the restoration and preservation of art treasures is considered. The processes discussed include both radiation grafting and rapid cure procedures, particularly reactions initiated by uv and eb. Representative examples where the technique has already been used are treated including typical applications with paintings, tapestries, leather and archival repair. The structure of the monomers and oligomers used in both grafting and rapid cure systems is outlined. The experimental conditions where grafting may occur during radiation rapid cure processing are discussed. Possible future developments of the technique are outlined. 1 figure, 8 tables.

  11. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Kumar, A.; Reddy, A.R.

    1994-01-01

    The last few years have seen a significant increase in the use of ionising radiation in industrial processes and also international trade in irradiated products. With this, the demand for internationally accepted dosimetric techniques, accredited to international standards has also increased which is further stimulated by the emergence of ISO-9000 series of standards in industries. The present paper describes some of the important dosimetric techniques used in radiation processing, the role of IAEA in evolving internationally accepted standards and work carried out at the Defence Laboratories, Jodhpur in the development of a cheap, broad dose range and simple dosimeter for routine dosimetry. For this polyhydroxy alcohols viz., mannitol, sorbitol and inositol were studied using the spectrophotometric read out method. Out of the alcohols studied mannitol was found to be most promising covering a dose range of 0.01 kGy - 100 kGy. (author). 26 refs., 3 figs., 1 tab

  12. The effects of radiation on p53-mutated glioma cells using cDNA microarray technique

    International Nuclear Information System (INIS)

    Ngo, F.Q.H.; Hsiao, Y.-Y.H.

    2003-01-01

    Full text: In this study, we investigated the effects of 10-Gy irradiation on cell-cycle arrest, apoptosis and clonogenic death in the p53-mutated human U138MG (malignant glioblastoma) cell line. In order to evaluate time-dependent events in cellular responses to radiation, we did a time course study by incubating cells ranging from 0.5 to 48 hours after irradiation. Cell-cycle distribution and apoptosis were evaluated by flow cytometry using propidium iodide (PI) and annexin-V plus PI staining. Cell viability and proliferative capacity were studied by colony formation assay. Dual fluorescence cDNA microarray technique was used to examine the differential expression patterns of the irradiated cells. The cDNA microarray chips used contained DNA sequences corresponding to 12,814 human genes. From the flow cytometry data, it can be observed that radiation induced G2/M phase arrest and that late apoptosis was more evident following G2/M arrest. After 36 hours, some cells underwent senescence and the remains continued on with the cell cycle. Microarray analyses revealed changes in the expression of a small number of cell-cycle-related genes (p21, cyclin B1, etc.) and cell-death genes (tumor necrosis factors, DDB2, etc.) suggesting their involvement in radiation-induced cell-cycle arrest and apoptosis. In silico interpretations of the molecular mechanisms responsible for these radiation effects are in progress

  13. Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniques

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai

    2013-01-01

    In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparison of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, within the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy. (author)

  14. A study on the hollow-out radiation technique applied to the protection of the spinal cord

    International Nuclear Information System (INIS)

    Matsuda, Tadayoshi

    1975-01-01

    The hollow-out radiation technique to protect the spinal cord in linear accelerator X-ray treatment of malignant diseases has been established in this study. Several kinds of diseases were selected as the subjects of the hollow-out technique to protect the cervical spinal cord, thoracic spinal cord, and dorsolumbar spinal cord from radiation, plus fundamental data, such as the materials, shapes and sizes of absorber, which are most appropriate for each of the diseases, were established. In all the cases receiving this technique, the necessary areas of therapy are covered by 80-90% dose distribution and the radiation dose of the spinal cord is kept below 40%. The fundamental data and irradiation conditions for the hollow-out technique of every part of the spinal cord were arranged from the results of phantom examinations on every part of the human body and from 42 cases actually treated. In the present study, the hollow-out technique for the cervical spinal cord, thoracic spinal cord, and dorsolumbar spinal cord is divided into 5 categories, and a method for the planning of radiation therapy and the actual treatment are described. The hollow-out radiation technique on the spinal cord is useful radiation therapy which can give better results by preventing radiation myelopathy. (auth.)

  15. Accreditation - Its relevance for laboratories measuring radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Palsson, S E [Icelandic Radiation Protection Inst. (Iceland)

    2001-11-01

    Accreditation is an internationally recognised way for laboratories to demonstrate their competence. Obtaining and maintaining accreditation is, however, a costly and time-consuming procedure. The benefits of accreditation also depend on the role of the laboratory. Accreditation may be of limited relevance for a research laboratory, but essential for a laboratory associated with a national authority and e.g. issuing certificates. This report describes work done within the NKSBOK-1.1 sub-project on introducing accreditation to Nordic laboratories measuring radionuclides. Initially the focus was on the new standard ISO/IEC 17025, which was just in a draft form at the time, but which provides now a new framework for accreditation of laboratories. Later the focus was widened to include a general introduction to accreditation and providing through seminars a forum for exchanging views on the experience laboratories have had in this field. Copies of overheads from the last such seminar are included in the appendix to this report. (au)

  16. The application of correlation techniques to the angular spectrum of scattered radiation from tokamak plasmas

    International Nuclear Information System (INIS)

    Nazikian, R.

    1990-07-01

    In the limit of the first Born approximation for a partially coherent secondary source, consisting of a spatially random plasma illuminated by a coherent plane wave, it is shown that the spectral coherence of the scattered radiation as measured on an arbitrary plane beyond the scatterer conveys information on the three dimensional intensity distribution of the random source. By defining a new two point statistical measure of the random field, closely related to the cross spectral density, we show that the fluctuation amplitude of the random source along the direction of the incident plane wave may by recovered from the measurement of the scattered radiation. The application of cross spectral techniques to fluctuation studies on tokamaks is considered. 7 refs

  17. Surface coating of jeungjing wood (Paraserianthes Falcataria (L) NIELSEN) with acrylate resins by using radiation technique

    International Nuclear Information System (INIS)

    Suhariyono, Gatot

    1998-01-01

    An experiment on surface coating with acrylate resins has been done by using radiation technique to improve the quality and added value of jeunjing wood (Paraserianthes Falcataria (L) NIELSEN). Doses used in Electron Beam (BE) radiation were 20, 40, and 60 kGy. Epoxy acrylate and ester acrylate resins were used as coating materials after added with tripropylene glycol diacylate (TPGDA) monomer, 2,2-dimethyl-2hidroxy acetophenone (Darocur 1173) photoinitiator and talc as base coat. Top coat consists of este acrylate Setacure AM 548, after added with titanium dioxide OK 412 as additive respectively. Titanium dioxides in the mixture were varied at the concentration level of 0, 2, 4 and 6 % by weight. Conventional coating as comparison was carried out by using varnish as coating material. The results showed that the properties of film on jeunjing wood by EB curing are better than that of conventional one. (authors)

  18. Univariate and multivariate forecasting of hourly solar radiation with artificial intelligence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Sfetsos, A. [7 Pirsou Str., Athens (Greece); Coonick, A.H. [Imperial Coll. of Science Technology and Medicine, Dept. of Electrical and Electronic Engineering, London (United Kingdom)

    2000-07-01

    This paper introduces a new approach for the forecasting of mean hourly global solar radiation received by a horizontal surface. In addition to the traditional linear methods, several artificial-intelligence-based techniques are studied. These include linear, feed-forward, recurrent Elman and Radial Basis neural networks alongside the adaptive neuro-fuzzy inference scheme. The problem is examined initially for the univariate case, and is extended to include additional meteorological parameters in the process of estimating the optimum model. The results indicate that the developed artificial intelligence models predict the solar radiation time series more effectively compared to the conventional procedures based on the clearness index. The forecasting ability of some models can be further enhanced with the use of additional meteorological parameters. (Author)

  19. Image processing techniques for thermal, x-rays and nuclear radiations

    International Nuclear Information System (INIS)

    Chadda, V.K.

    1998-01-01

    The paper describes image acquisition techniques for the non-visible range of electromagnetic spectrum especially thermal, x-rays and nuclear radiations. Thermal imaging systems are valuable tools used for applications ranging from PCB inspection, hot spot studies, fire identification, satellite imaging to defense applications. Penetrating radiations like x-rays and gamma rays are used in NDT, baggage inspection, CAT scan, cardiology, radiography, nuclear medicine etc. Neutron radiography compliments conventional x-rays and gamma radiography. For these applications, image processing and computed tomography are employed for 2-D and 3-D image interpretation respectively. The paper also covers main features of image processing systems for quantitative evaluation of gray level and binary images. (author)

  20. Impact of advanced microstructural characterization techniques on modeling and analysis of radiation damage

    International Nuclear Information System (INIS)

    Garner, F.A.; Odette, G.R.

    1980-01-01

    The evolution of radiation-induced alterations of dimensional and mechanical properties has been shown to be a direct and often predictable consequence of radiation-induced microstructural changes. Recent advances in understanding of the nature and role of each microstructural component in determining the property of interest has led to a reappraisal of the type and priority of data needed for further model development. This paper presents an overview of the types of modeling and analysis activities in progress, the insights that prompted these activities, and specific examples of successful and ongoing efforts. A review is presented of some problem areas that in the authors' opinion are not yet receiving sufficient attention and which may benefit from the application of advanced techniques of microstructural characterization. Guidelines based on experience gained in previous studies are also provided for acquisition of data in a form most applicable to modeling needs

  1. Microbiological method for radiation sterilization (I). General knowledge and handling technique for bacterial identification

    International Nuclear Information System (INIS)

    Koshikawa, Tomihiko

    2004-01-01

    The part I in this title series describes the basic knowledge and technique for identification of bacteria in the radiation sterilization of medical devices, where the radiation dose can be decided from the number and radio-resistance of the bioburden (bacteria on the device). Four essential, actual technologies for identification are described: isolation and storage of bacteria; decision of bacterial natures, involving 3 Gram staining methods, morphology by microscopy and/or phase-contrast microscopy, spore-forming bacteria, and size measurement by micrometry; Other test items for identification of genus, involving motility, oxygen demand, catalase, oxidase, acid production from glucose, and OF (oxidation or fermentation for glucose degradation) test; and colony observation. Media, identification kits and record forms for these are presented. (N.I.)

  2. Reply on the comment of the paper "New probing techniques of radiative shocks"

    Science.gov (United States)

    Stehlé, Chantal; Kozlová, Michaela; Larour, Jean; Nejdl, Jaroslav; Suzuki-Vidal, Francisco; Cohen, Mathieu; Chaulagain, Uddhab P.; Champion, Norbert; Barroso, Patrice; Acef, Ouali; Delattre, Pierre-Alexandre; Dostál, Jan; Krus, Miroslav; Chièze, Jean-Pierre; Ibgui, Laurent

    2014-05-01

    Imaging the structure of a radiative shock is a challenging task as the high plasma densities produced need a short wavelength to penetrate the plasma, requiring highly sophisticated imaging techniques. In a recent paper (Stehlé et al., Opt. Commun. 285 (2012) 64-69 [1]) the feasibility of a novel imaging technique using an X-ray laser (XRL) at 21 nm with a pulse duration 0.15 ns was proved. The recorded image was attributed to a shock propagating with a velocity of ~60 km/s. This velocity is in agreement with measurements of the plasma self-emission using time and space resolved diode diagnostics, and also in qualitative agreement with 1D numerical simulations. However, due to the inhomogeneous reflectivity of the XUV imaging mirror and to the low number of XRL photons, the quality of the recorded image was insufficient to unambiguously identify the different shock regions. Thus, arguing an ad hoc spatial resolution of ~0.5 mm and a stepwise representation of the shock-piston system, the potential of the technique to observe a radiative precursor was contested (Busquet's comment (in press) [2]). In this reply we aim at clarifying different aspects of the experimental setup, spatial resolution and other questions raised in this comment in order to back up our findings together with their respective analysis and interpretations.

  3. Regulatory issues in accreditation of toxicology laboratories.

    Science.gov (United States)

    Bissell, Michael G

    2012-09-01

    Clinical toxicology laboratories and forensic toxicology laboratories operate in a highly regulated environment. This article outlines major US legal/regulatory issues and requirements relevant to accreditation of toxicology laboratories (state and local regulations are not covered in any depth). The most fundamental regulatory distinction involves the purposes for which the laboratory operates: clinical versus nonclinical. The applicable regulations and the requirements and options for operations depend most basically on this consideration, with clinical toxicology laboratories being directly subject to federal law including mandated options for accreditation and forensic toxicology laboratories being subject to degrees of voluntary or state government–required accreditation.

  4. Accreditation and Expansion in Danish Higher Education

    DEFF Research Database (Denmark)

    Rasmussen, Palle

    2014-01-01

    During the last decade, an accreditation system for higher education has been introduced in Denmark. Accreditation partly represents continuity from an earlier evaluation system, but it is also part of a government policy to increasingly define higher education institutions as market actors....... The attempts of universities to increase their student enrolments have combined with the logic of accreditation to produce an increasing number of higher education degrees, often overlapping in content. Students’ scope for choice has been widened, but the basis for and the consequences of choice have become...

  5. Surgical techniques in radiation induced temporal lobe necrosis in nasopharyngeal carcinoma patients.

    Science.gov (United States)

    Alfotih, Gobran Taha Ahmed; Zheng, Mei Guang; Cai, Wang Qing; Xu, Xin Ke; Hu, Zhen; Li, Fang Cheng

    2016-01-01

    Radiation induced brain injury ranges from acute reversible edema to late, irreversible radiation necrosis. Radiation induced temporal lobe necrosis is associated with permanent neurological deficits and occasionally progresses to death. We present our experience with surgery on radiation induced temporal lobe necrosis (RTLN) in nasopharyngeal carcinoma (NPC) patients with special consideration of clinical presentation, surgical technique, and outcomes. This retrospective study includes 12 patients with RTLN treated by the senior author between January 2010 and December 2014. Patients initially sought medical treatment due to headache; other symptoms were hearing loss, visual deterioration, seizure, hemiparesis, vertigo, memory loss and agnosia. A temporal approach through a linear incision was performed for all cases. RTLN was found in one side in 7 patients, and bilaterally in 5. 4 patients underwent resection of necrotic tissue bilaterally and 8 patients on one side. No death occurred in this series of cases. There were no post-operative complications, except 1 patient who developed aseptic meningitis. All 12 patients were free from headache. No seizure occurred in patients with preoperative epilepsy. Other symptoms such as hemiparesis and vertigo improved in all patients. Memory loss, agnosia and hearing loss did not change post-operatively in all cases. The follow-up MR images demonstrated no recurrence of necrotic lesions in all 12 patients. Neurosurgical intervention through a temporal approach with linear incision is warranted in patients with radiation induced temporal lobe necrosis with significant symptoms and signs of increased intracranial pressure, minimum space occupying effect on imaging, or neurological deterioration despite conservative management. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  6. Review of personal monitoring techniques for the measurement of absorbed dose from external beta and low energy photon radiation

    DEFF Research Database (Denmark)

    Christensen, Poul

    1986-01-01

    The techniques available at present for personal monitoring of doses from external beta and low energy photon radiation are reviewed. The performance of currently used dosimetry systems is compared with that recommended internationally, and developments for improving the actual performance...

  7. Measurement techniques and safety culture in radiation protection -reflections after 37 years of occupation with measuring instruments

    International Nuclear Information System (INIS)

    Maushart, R.

    1994-01-01

    Safety Culture in radiation use and radiation protection implies primarily knowledge and competence of the decision makers. As the measuring techniques are basic for practical radiation protection, only such person can be called competent who has sufficient expertise on measuring techniques, and is able to evaluate its application and results. Safety Culture also implies the readiness to expose errors, and to learn from them. ''Believing in infallibility'' excludes Safety Culture. Therefore, correctly applied measuring technique contributes to recognize weak points early. How far it is used consciously and actively to prevent undesirable developments and exceeding of limits, can be considered outright as a yardstick for a high-ranking safety culture. Safety Culture as a whole, however, needs more than more measuring techniques. It requires its own and adequate Measurement Culture, presupposing also motivation and determination to measure. Therefore, education, training, knowledge and consciousness of safety of the people who are responsible for measurements are decisive for successful radiation protection. (orig.) [de

  8. Novel technique for manipulating MOX fuel particles using radiation pressure of a laser light

    International Nuclear Information System (INIS)

    Omori, R.; Suzuki, A.

    2001-01-01

    We proposed two principles based on the laser manipulation technique for collecting MOX fuel particles floating in air. While Principle A was based on the acceleration of the MOX particles due to the radiation pressure of a visible laser light, Principle B was based on the gradient forces exerted on the particles when an infrared laser light was incident. Principle A was experimentally verified using MnO 2 particles. Numerical results also showed the possibility of collecting MOX fuel particles based on both the principles. (authors)

  9. RADIATION PROTECTION – AN ISSUE OF KNOWLEDGE AND TECHNIQUE IN DENTAL OFFICES

    Directory of Open Access Journals (Sweden)

    Mariana CONSTANTINIUC

    2016-06-01

    Full Text Available Radiological examination is indispensable in current dental practice. Lately, dentists have become not only the beneficiaries of radiographic investigations required for diagnosis, but also their authors, as many dental offices have been authorized to have X-ray machines and carry out radiological activity. This is why dentists who perform dental X-rays have the legal and moral obligation to possess thorough theoretical and practical knowledge about the radiological technique and also about their own and patients’ radiation protection. This study investigates to what extent medical practitioners providing dental radiology services know and apply the technical norms for work and patient protection

  10. Study of poli (ethylene tereftalate) thin films submitted to radiations by using permeation and spectroscopic techniques

    International Nuclear Information System (INIS)

    Andrade, L.A.

    1986-06-01

    Properties of poly (ethylene terephthalate P.E.T. thin films submitted to electric discharges, electron, He + ion and proton beams were investigated using permeation technique, electronic paramagnetic resonance resonance (E.P.R.) and visible and infrared spectroscopies. Experimental apparatuses and procedures are described and the results of the analyses are presented and discussed. The existence of structural modifications in irradiated P.E.T. thin films is confirmed. It is shown that the kind of effects occuring in irradiated P.E.T. depends on the nature of the incident radiation. (author) [pt

  11. Chemical stability of fluorine-containing coatings of cold drying for radiation - protection technique articles

    International Nuclear Information System (INIS)

    Shigorina, I.I.; Zvyagintseva, N.V.; Egorov, B.N.

    1977-01-01

    The chemical stability of fluorolon coatings, which are not subjected to heat treatment or hot drying during application, has been studied. The test for layer life-time has been performed by submerging specimens in agressive medium. The time for one upper removable layer to fail under steady action of agressive liquid is found to be: > 12 months at 20 deg C, 6-9 months at 40 deg C; at 60 deg C the time of layer stability depends upon medium: 1 month for nitric, 2 months for acetic, 2-3 months for sulphuric and hydrochloric acid. The coatings are recommended for practical application in radiation-protective technique

  12. Nuclear and radiation techniques - state of art and development trends; Techniki jadrowe i radiacyjne - stan obecny oraz kierunki rozwoju

    Energy Technology Data Exchange (ETDEWEB)

    Chmielewski, A.G. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1995-12-31

    The state of art and development trends of nuclear and radiation techniques in Poland and worldwide have been presented. Among them the radiometric gages, radiation technologies, radiotracer methods and measuring systems for pipeline and vessels, brightness control have been described and their applications in industry, agriculture, health and environment protection have been shown and discussed. 35 refs, 1 fig.

  13. Modelling techniques for predicting the long term consequences of radiation on natural aquatic populations

    International Nuclear Information System (INIS)

    Wallis, I.G.

    1978-01-01

    The purpose of this working paper is to describe modelling techniques for predicting the long term consequences of radiation on natural aquatic populations. Ideally, it would be possible to use aquatic population models: (1) to predict changes in the health and well-being of all aquatic populations as a result of changing the composition, amount and location of radionuclide discharges; (2) to compare the effects of steady, fluctuating and accidental releases of radionuclides; and (3) to evaluate the combined impact of the discharge of radionuclides and other wastes, and natural environmental stresses on aquatic populations. At the onset it should be stated that there is no existing model which can achieve this ideal performance. However, modelling skills and techniques are available to develop useful aquatic population models. This paper discusses the considerations involved in developing these models and briefly describes the various types of population models which have been developed to date

  14. Field transients of coherent terahertz synchrotron radiation accessed via time-resolving and correlation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Pohl, A.; Hübers, H.-W. [Humboldt-Universität zu Berlin, Institute of Physics, Newtonstraße 15, 12489 Berlin (Germany); Institute of Optical Sensor Systems, German Aerospace Center (DLR), Rutherfordstrasse 29, 12489 Berlin (Germany); Semenov, A. [Institute of Optical Sensor Systems, German Aerospace Center (DLR), Rutherfordstrasse 29, 12489 Berlin (Germany); Hoehl, A.; Ulm, G. [Physikalisch-Technische Bundesanstalt (PTB), Abbestraße 2-12, 10587 Berlin (Germany); Ries, M.; Wüstefeld, G. [Helmholz-Zentrum Berlin, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Ilin, K.; Thoma, P.; Siegel, M. [Institute of Micro- and Nanoelectronic Systems, Karlsruhe Institute of Technology (KIT), Hertzstrasse 16, 76187 Karlsruhe (Germany)

    2016-03-21

    Decaying oscillations of the electric field in repetitive pulses of coherent synchrotron radiation in the terahertz frequency range was evaluated by means of time-resolving and correlation techniques. Comparative analysis of real-time voltage transients of the electrical response and interferograms, which were obtained with an ultrafast zero-bias Schottky diode detector and a Martin-Puplett interferometer, delivers close values of the pulse duration. Consistent results were obtained via the correlation technique with a pair of Golay Cell detectors and a pair of resonant polarisation-sensitive superconducting detectors integrated on one chip. The duration of terahertz synchrotron pulses does not closely correlate with the duration of single-cycle electric field expected for the varying size of electron bunches. We largely attribute the difference to the charge density oscillations in electron bunches and to the low-frequency spectral cut-off imposed by both the synchrotron beamline and the coupling optics of our detectors.

  15. Synchrotron radiation microtomography of musical instruments: a non-destructive monitoring technique for insect infestations

    Directory of Open Access Journals (Sweden)

    Beatrice Bentivoglio-Ravasio

    2011-08-01

    Full Text Available X-ray computed tomography is becoming a common technique for the structural analysis of samples of cultural relevance, providing luthiers, art historians, conservators and restorators with a unique tool for the characterization of musical instruments. Synchrotron-radiation phase-contrast microtomography is an ideal technique for the non-destructive 3D analysis of samples where small lowabsorbing details such as larvae and eggs can be detected. We report results from the first feasibility studies performed at the Elettra synchrotron laboratory, where the 1494 organ by Lorenzo Gusnasco da Pavia has been studied. Together with important information about the structural conditions, the presence of xylophages could be detected and characterized.

  16. Thermal radiation characteristics of nonisothermal cylindrical enclosures using a numerical ray tracing technique

    Science.gov (United States)

    Baumeister, Joseph F.

    1990-01-01

    Analysis of energy emitted from simple or complex cavity designs can lead to intricate solutions due to nonuniform radiosity and irradiation within a cavity. A numerical ray tracing technique was applied to simulate radiation propagating within and from various cavity designs. To obtain the energy balance relationships between isothermal and nonisothermal cavity surfaces and space, the computer code NEVADA was utilized for its statistical technique applied to numerical ray tracing. The analysis method was validated by comparing results with known theoretical and limiting solutions, and the electrical resistance network method. In general, for nonisothermal cavities the performance (apparent emissivity) is a function of cylinder length-to-diameter ratio, surface emissivity, and cylinder surface temperatures. The extent of nonisothermal conditions in a cylindrical cavity significantly affects the overall cavity performance. Results are presented over a wide range of parametric variables for use as a possible design reference.

  17. Linearized Flux Evolution (LiFE): A technique for rapidly adapting fluxes from full-physics radiative transfer models

    Science.gov (United States)

    Robinson, Tyler D.; Crisp, David

    2018-05-01

    Solar and thermal radiation are critical aspects of planetary climate, with gradients in radiative energy fluxes driving heating and cooling. Climate models require that radiative transfer tools be versatile, computationally efficient, and accurate. Here, we describe a technique that uses an accurate full-physics radiative transfer model to generate a set of atmospheric radiative quantities which can be used to linearly adapt radiative flux profiles to changes in the atmospheric and surface state-the Linearized Flux Evolution (LiFE) approach. These radiative quantities describe how each model layer in a plane-parallel atmosphere reflects and transmits light, as well as how the layer generates diffuse radiation by thermal emission and by scattering light from the direct solar beam. By computing derivatives of these layer radiative properties with respect to dynamic elements of the atmospheric state, we can then efficiently adapt the flux profiles computed by the full-physics model to new atmospheric states. We validate the LiFE approach, and then apply this approach to Mars, Earth, and Venus, demonstrating the information contained in the layer radiative properties and their derivatives, as well as how the LiFE approach can be used to determine the thermal structure of radiative and radiative-convective equilibrium states in one-dimensional atmospheric models.

  18. Matlab fractal techniques used to study the structural degradation caused by alpha radiation to laser mirrors

    Science.gov (United States)

    Ioan, M.-R.

    2018-01-01

    Almost all optical diagnostic systems associated with classical particle accelerators or with new state-of-the-art particle accelerators, such as those developed within the European Collaboration ELI-NP (Extreme Light Infrastructure-Nuclear Physics) (involving extreme power laser beams), contain in their infrastructure high quality laser mirrors, used for their reflectivity and/or their partial transmittance. These high quality mirrors facilitate the extraction and handling of optical signals. When optical mirrors are exposed to high energy ionizing radiation fields, their optical and structural properties will change over time and their functionality will be affected, meaning that they will provide imprecise information. In some experiments, being exposed to mixed laser and accelerated particle beams, the deterioration of laser mirrors is even more acute, since the destruction mechanisms of both types of beams are cumulated. The main task of the work described in this paper was to find a novel specific method to analyse and highlight such degradation processes. By using complex fractal techniques integrated in a MATLAB code, the effects induced by alpha radiation to laser mirrors were studied. The fractal analysis technique represents an alternative approach to the classical Euclidean one. It can be applied for the characterization of the defects occurred in mirrors structure due to their exposure to high energy alpha particle beams. The proposed method may be further integrated into mirrors manufacturing process, as a testing instrument, to obtain better quality mirrors (enhanced resistance to high energy ionizing beams) by using different types of reflective coating materials and different deposition techniques. Moreover, the effect of high energy alpha ionizing particles on the optical properties of the exposed laser mirrors was studied by using spectrophotometric techniques.

  19. Impact of National Universities Commission (NUC) Accreditation ...

    African Journals Online (AJOL)

    Nekky Umera

    (NUC) accreditation exercise on university administrative structure of four selected Nigerian ... The Commission's recommendations led to the setting up by Government the National ... For instance, the goals of tertiary education as spelt out in ...

  20. Accreditation of undergraduate and graduate medical education

    DEFF Research Database (Denmark)

    Davis, Deborah J; Ringsted, Charlotte

    2006-01-01

    Accreditation organizations such as the Liaison Committee for Medical Education (LCME), the Royal College of Physicians and Surgeons of Canada (RCPSC), and the Accreditation Council for Graduate Medical Education (ACGME) are charged with the difficult task of evaluating the educational quality...... of medical education programs in North America. Traditionally accreditation includes a more quantitative rather than qualitative judgment of the educational facilities, resources and teaching provided by the programs. The focus is on the educational process but the contributions of these to the outcomes...... are not at all clear. As medical education moves toward outcome-based education related to a broad and context-based concept of competence, the accreditation paradigm should change accordingly. Udgivelsesdato: 2006-Aug...

  1. Student Affairs Assessment, Strategic Planning, and Accreditation

    Science.gov (United States)

    Fallucca, Amber

    2017-01-01

    This chapter illustrates how student affairs units participate in accreditation across regional agency expectations and program-level requirements. Strategies for student affairs units to engage in campus strategic planning processes to further highlight their contributions are also recommended.

  2. 42 CFR 424.58 - Accreditation.

    Science.gov (United States)

    2010-10-01

    ... enforcing the DMEPOS quality standards for suppliers of DMEPOS and other items or services. Section 1847(b... disparity, there are widespread or systemic problems in an organization's accreditation process such that...

  3. New horizontal global solar radiation estimation models for Turkey based on robust coplot supported genetic programming technique

    International Nuclear Information System (INIS)

    Demirhan, Haydar; Kayhan Atilgan, Yasemin

    2015-01-01

    Highlights: • Precise horizontal global solar radiation estimation models are proposed for Turkey. • Genetic programming technique is used to construct the models. • Robust coplot analysis is applied to reduce the impact of outlier observations. • Better estimation and prediction properties are observed for the models. - Abstract: Renewable energy sources have been attracting more and more attention of researchers due to the diminishing and harmful nature of fossil energy sources. Because of the importance of solar energy as a renewable energy source, an accurate determination of significant covariates and their relationships with the amount of global solar radiation reaching the Earth is a critical research problem. There are numerous meteorological and terrestrial covariates that can be used in the analysis of horizontal global solar radiation. Some of these covariates are highly correlated with each other. It is possible to find a large variety of linear or non-linear models to explain the amount of horizontal global solar radiation. However, models that explain the amount of global solar radiation with the smallest set of covariates should be obtained. In this study, use of the robust coplot technique to reduce the number of covariates before going forward with advanced modelling techniques is considered. After reducing the dimensionality of model space, yearly and monthly mean daily horizontal global solar radiation estimation models for Turkey are built by using the genetic programming technique. It is observed that application of robust coplot analysis is helpful for building precise models that explain the amount of global solar radiation with the minimum number of covariates without suffering from outlier observations and the multicollinearity problem. Consequently, over a dataset of Turkey, precise yearly and monthly mean daily global solar radiation estimation models are introduced using the model spaces obtained by robust coplot technique and

  4. International Perspectives on Quality Assurance and New Techniques in Radiation Medicine: Outcomes of an IAEA Conference

    International Nuclear Information System (INIS)

    Shortt, Ken; Davidsson, Lena; Hendry, Jolyon; Dondi, Maurizio; Andreo, Pedro

    2008-01-01

    The International Atomic Energy Agency organized an international conference called, 'Quality Assurance and New Techniques in Radiation Medicine' (QANTRM). It dealt with quality assurance (QA) in all aspects of radiation medicine (diagnostic radiology, nuclear medicine, and radiotherapy) at the international level. Participants discussed QA issues pertaining to the implementation of new technologies and the need for education and staff training. The advantage of developing a comprehensive and harmonized approach to QA covering both the technical and the managerial issues was emphasized to ensure the optimization of benefits to patient safety and effectiveness. The necessary coupling between medical radiation imaging and radiotherapy was stressed, particularly for advanced technologies. However, the need for a more systematic approach to the adoption of advanced technologies was underscored by a report on failures in intensity-modulated radiotherapy dosimetry auditing tests in the United States, which could imply inadequate implementation of QA for these new technologies. A plenary session addressed the socioeconomic impact of introducing advanced technologies in resource-limited settings. How shall the dual gaps, one in access to basic medical services and the other in access to high-quality modern technology, be addressed?

  5. International perspectives on quality assurance and new techniques in radiation medicine: outcomes of an IAEA conference.

    Science.gov (United States)

    Shortt, Ken; Davidsson, Lena; Hendry, Jolyon; Dondi, Maurizio; Andreo, Pedro

    2008-01-01

    The International Atomic Energy Agency organized an international conference called, "Quality Assurance and New Techniques in Radiation Medicine" (QANTRM). It dealt with quality assurance (QA) in all aspects of radiation medicine (diagnostic radiology, nuclear medicine, and radiotherapy) at the international level. Participants discussed QA issues pertaining to the implementation of new technologies and the need for education and staff training. The advantage of developing a comprehensive and harmonized approach to QA covering both the technical and the managerial issues was emphasized to ensure the optimization of benefits to patient safety and effectiveness. The necessary coupling between medical radiation imaging and radiotherapy was stressed, particularly for advanced technologies. However, the need for a more systematic approach to the adoption of advanced technologies was underscored by a report on failures in intensity-modulated radiotherapy dosimetry auditing tests in the United States, which could imply inadequate implementation of QA for these new technologies. A plenary session addressed the socioeconomic impact of introducing advanced technologies in resource-limited settings. How shall the dual gaps, one in access to basic medical services and the other in access to high-quality modern technology, be addressed?

  6. Cancer of the breast: Conservation surgery and curative radiation therapy - Technique

    International Nuclear Information System (INIS)

    Brady, L.W.; Bedwinek, J.M.; Markoe, A.M.; Micaily, B.; Damsker, J.I.; Karlsson, U.L.

    1987-01-01

    Current evidence strongly suggests that radiation therapy following conservation surgery in the primary local management of stage I and stage II breast cancer can achieve survival and local-regional control rates that are comparable to those obtained by radical and modified radical mastectomy. Since primary radiation therapy has the benefit of leaving the patient with intact and cosmetically acceptable breasts, it should be considered as a viable and reasonable alternative to radical mastectomy. An analysis of current series of primary radiation data suggests that total excision of the tumor should be carried out. An axillary node sampling or dissection including level 1 and level 2 axillary nodes (those lying beneath and lateral to the pectoralis minor muscle) should be carried out in addition to tumor excision since knowledge of the axillary nodal status serves as a prognostic indicator and facilitates the intelligent selection of those patients for adjuvant hormonal or chemotherapy. Technique then becomes a critical and important part of the management of the patient. No effort should be spared to insure that the volumes irradiated are properly chosen, receive the appropriate dose to maximize the potential for local-regional control and done within the context of minimization of complication from the treatment program. It is only under these circumstances that the best in terms of long-term survival and cosmetic can be achieved

  7. Carcinoma of the cervical esophagus treated with radiation therapy using a four-field box technique

    International Nuclear Information System (INIS)

    Mendenhall, W.M.; Million, R.R.; Bova, F.J.

    1982-01-01

    This is a retrospective analysis of 16 patients with carcinoma of the cervical esophagus treated with radiation therapy at the University of Florida between September 1966 and March 1979. There is a minimum 2-year followup. Analysis of local control revealed 1/1 T1, 0/3 T2, 2/8 T3, and 1/2 TX lesions that were controlled by radiation therapy for 33, 47, 55, and 80 months. Two patients died less than 2 years after treatment without evidence of cancer. Excluding the sole T1 lesion, there were no local controls below 6700 rad; 3 of 5 lesions were controlled at doses in excess of 6700 rad. Late complications were stenosis (2 patients) and Lhermitte's syndrome (1 patient). An external beam technique consisting of an isocentric four-field box with a beeswax compensator has been devised in an effort to solve the technical problems in delivering high-dose radiation to the primary and regional nodes without producing myelitis

  8. GENERALISATION OF RADIATOR DESIGN TECHNIQUES FOR PERSONAL NEUTRON DOSEMETERS BY UNFOLDING METHOD.

    Science.gov (United States)

    Oda, K; Nakayama, T; Umetani, K; Kajihara, M; Yamauchi, T

    2016-09-01

    A novel technique for designing a radiator suitable for personal neutron dosemeter based on plastic track detector was discussed. A multi-layer structure has been proposed in the previous report, where the thicknesses of plural polyethylene (PE) layers and insensitive ones were determined by iterative calculations of double integral. In order to arrange this procedure and make it more systematic, unfolding calculation has been employed to estimate an ideal radiator containing an arbitrary hydrogen concentration. In the second step, realistic materials replaced it with consideration of minimisation of the layer number and commercial availability. A radiator consisting of three layers of PE, Upilex and Kapton sheets was finally designed, for which a deviation in the energy dependence between 0.1 and 20 MeV could be controlled within 18 %. An applicability of fluorescent nuclear track detector element has also been discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Numerical analysis of radiation propagation in innovative volumetric receivers based on selective laser melting techniques

    Science.gov (United States)

    Alberti, Fabrizio; Santiago, Sergio; Roccabruna, Mattia; Luque, Salvador; Gonzalez-Aguilar, Jose; Crema, Luigi; Romero, Manuel

    2016-05-01

    Volumetric absorbers constitute one of the key elements in order to achieve high thermal conversion efficiencies in concentrating solar power plants. Regardless of the working fluid or thermodynamic cycle employed, design trends towards higher absorber output temperatures are widespread, which lead to the general need of components of high solar absorptance, high conduction within the receiver material, high internal convection, low radiative and convective heat losses and high mechanical durability. In this context, the use of advanced manufacturing techniques, such as selective laser melting, has allowed for the fabrication of intricate geometries that are capable of fulfilling the previous requirements. This paper presents a parametric design and analysis of the optical performance of volumetric absorbers of variable porosity conducted by means of detailed numerical ray tracing simulations. Sections of variable macroscopic porosity along the absorber depth were constructed by the fractal growth of single-cell structures. Measures of performance analyzed include optical reflection losses from the absorber front and rear faces, penetration of radiation inside the absorber volume, and radiation absorption as a function of absorber depth. The effects of engineering design parameters such as absorber length and wall thickness, material reflectance and porosity distribution on the optical performance of absorbers are discussed, and general design guidelines are given.

  10. 42 CFR Appendix A to Part 75 - Standards for Accreditation of Educational Programs for Radiographers

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Standards for Accreditation of Educational Programs for Radiographers A Appendix A to Part 75 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH... film evaluation; (k) Methods of patient care; (l) Pathology; (m) Radiologic physics; and (n) Radiation...

  11. Radiation shielding techniques and applications. 3. Analysis of Photon Streaming Through and Around Shield Doors

    International Nuclear Information System (INIS)

    Barnett, Marvin; Hack, Joe; Nathan, Steve; White, Travis

    2001-01-01

    Westinghouse Safety Management Solutions (Westinghouse SMS) has been tasked with providing radiological engineering design support for the new Commercial Light Water Reactor Tritium Extraction Facility (CLWR-TEF) being constructed at the Savannah River Site (SRS). The Remote Handling Building (RHB) of the CLWR-TEF will act as the receiving facility for irradiated targets used in the production of tritium for the U.S. Department of Energy (DOE). Because of the high dose rates, approaching 50 000 rads/h (500 Gy/h) from the irradiated target bundles, significant attention has been made to shielding structures within the facility. One aspect of the design that has undergone intense review is the shield doors. The RHB has six shield doors that needed to be studied with respect to photon streaming. Several aspects had to be examined to ensure that the design meets the radiation dose levels. Both the thickness and streaming issues around the door edges were designed and examined. Photon streaming through and around a shield door is a complicated problem, creating a reliance on computer modeling to perform the analyses. The computer code typically used by the Westinghouse SMS in the evaluation of photon transport through complex geometries is the MCNP Monte Carlo computer code. The complexity of the geometry within the problem can cause problems even with the Monte Carlo codes. Striking a balance between how the code handles transport through the shield door with transport through the streaming paths, particularly with the use of typical variance reduction methods, is difficult when trying to ensure that all important regions of the model are sampled appropriately. The thickness determination used a simple variance reduction technique. In construction, the shield door will not be flush against the wall, so a solid rectangular slab leaves streaming paths around the edges. Administrative controls could be used to control dose to workers; however, 10 CFR 835.1001 states

  12. Trust, accreditation and Philanthropy in the Netherlands

    OpenAIRE

    Bekkers, R.H.F.P.

    2003-01-01

    Given the increasing numbers of scandals, the awareness among fund-raisers that the public’s trust is crucial for the nonprofit sector is growing. This study investigates the relationship between trust and charitable giving. Charitable organizations can increase the public’s trust by signaling their trustworthiness. The example of the Netherlands shows how a system of accreditation can be an instrument for signaling trustworthiness to the public. Donors aware of the accreditation system have ...

  13. Implementation of quality management systems and progress towards accreditation of National Tuberculosis Reference Laboratories in Africa

    Directory of Open Access Journals (Sweden)

    Heidi Albert

    2017-03-01

    Full Text Available Background: Laboratory services are essential at all stages of the tuberculosis care cascade, from diagnosis and drug resistance testing to monitoring response to treatment. Enabling access to quality services is a challenge in low-resource settings. Implementation of a strong quality management system (QMS and laboratory accreditation are key to improving patient care. Objectives: The study objective was to determine the status of QMS implementation and progress towards accreditation of National Tuberculosis Reference Laboratories (NTRLs in the African Region. Method: An online questionnaire was administered to NTRL managers in 47 World Health Organization Regional Office for Africa member states in the region, between February and April 2015, regarding the knowledge of QMS tools and progress toward implementation to inform strategies for tuberculosis diagnostic services strengthening in the region. Results: A total of 21 laboratories (43.0% had received SLMTA/TB-SLMTA training, of which 10 had also used the Global Laboratory Initiative accreditation tool. However, only 36.7% of NTRLs had received a laboratory audit, a first step in quality improvement. Most NTRLs participated in acid-fast bacilli microscopy external quality assurance (95.8%, although external quality assurance for other techniques was lower (60.4% for first-line drug susceptibility testing, 25.0% for second-line drug susceptibility testing, and 22.9% for molecular testing. Barriers to accreditation included lack of training and accreditation programmes. Only 28.6%of NTRLs had developed strategic plans and budgets which included accreditation. Conclusion: Good foundations are in place on the continent from which to scale up accreditation efforts. Laboratory audits should be conducted as a first step in developing quality improvement action plans. Political commitment and strong leadership are needed to drive accreditation efforts; advocacy will require clear evidence of patient

  14. Radiation treatment for the right naris in a pediatric anesthesia patient using an adaptive oral airway technique

    Energy Technology Data Exchange (ETDEWEB)

    Sponseller, Patricia, E-mail: sponselp@uw.edu; Pelly, Nicole; Trister, Andrew; Ford, Eric; Ermoian, Ralph

    2015-10-01

    Radiation therapy for pediatric patients often includes the use of intravenous anesthesia with supplemental oxygen delivered via the nasal cannula. Here, we describe the use of an adaptive anesthesia technique for electron irradiation of the right naris in a preschool-aged patient treated under anesthesia. The need for an intranasal bolus plug precluded the use of standard oxygen supplementation. This novel technique required the multidisciplinary expertise of anesthesiologists, radiation therapists, medical dosimetrists, medical physicists, and radiation oncologists to ensure a safe and reproducible treatment course.

  15. Radiation treatment for the right naris in a pediatric anesthesia patient using an adaptive oral airway technique

    International Nuclear Information System (INIS)

    Sponseller, Patricia; Pelly, Nicole; Trister, Andrew; Ford, Eric; Ermoian, Ralph

    2015-01-01

    Radiation therapy for pediatric patients often includes the use of intravenous anesthesia with supplemental oxygen delivered via the nasal cannula. Here, we describe the use of an adaptive anesthesia technique for electron irradiation of the right naris in a preschool-aged patient treated under anesthesia. The need for an intranasal bolus plug precluded the use of standard oxygen supplementation. This novel technique required the multidisciplinary expertise of anesthesiologists, radiation therapists, medical dosimetrists, medical physicists, and radiation oncologists to ensure a safe and reproducible treatment course

  16. Beyond accreditation: excellence in medical education.

    Science.gov (United States)

    Ahn, Eusang; Ahn, Ducksun

    2014-01-01

    Medical school accreditation is a relatively new phenomenon in Korea. The development of an accreditation body and standards for a two-tiered "Must" and "Should" system in 1997 eventually led to the implementation of a third "Excellence" level of attainment. These standards were conceived out of a desire to be able to first recognize and promote outstanding performance of medical schools, second to provide role models in medical education, and furthermore to preview the third level as potential components of the pre-existing second level for the next accreditation cycle. It is a quality-assurance mechanism that, while not required for accreditation itself, pushes medical schools to go beyond the traditional requirements of mere pass-or-fail accreditation adequacy, and encourages schools to deliver an unprecedented level of medical education. The Association for Medical Education in Europe developed its own third-tier system of evaluation under the ASPIRE project, with many similar goals. Due to its advanced nature and global scope, the Korean accreditation body has decided to implement the ASPIRE system in Korea as well.

  17. Medical students’ perceptions of international accreditation

    Science.gov (United States)

    Abdel-Razig, Sawsan; Nair, Satish C

    2015-01-01

    Objectives This study aimed to explore the perceptions of medical students in a developing medical education system towards international accreditation. Methods Applicants to an Internal Medicine residency program in an academic medical center in the United Arab Emirates (UAE) accredited by the Accreditation Council for Graduate Medical Education-International (ACGME-I) were surveyed between May and June 2014. The authors analysed responses using inductive qualitative thematic analysis to identify emergent themes. Results Seventy-eight of 96 applicants (81%) completed the survey. The vast majority of respondents 74 (95%) reported that ACGME-I accreditation was an important factor in selecting a residency program. Five major themes were identified, namely improving the quality of education, increasing opportunities, meeting high international standards, improving program structure, and improving patient care. Seven (10%) of respondents felt they would be in a position to pursue fellowship training or future employment in the United States upon graduation from an ACGME-I program. Conclusions UAE trainees have an overwhelmingly positive perception of international accreditation, with an emphasis on improving the quality of training provided. Misperceptions, however, exist about potential opportunities available to graduates of ACGME-I programs. As more countries adopt the standards of the ACGME-I or other international accrediting bodies, it is important to recognize and foster trainee “buy-in” of educational reform initiatives. PMID:26454402

  18. Medical students' perceptions of international accreditation.

    Science.gov (United States)

    Ibrahim, Halah; Abdel-Razig, Sawsan; Nair, Satish C

    2015-10-11

    This study aimed to explore the perceptions of medical students in a developing medical education system towards international accreditation. Applicants to an Internal Medicine residency program in an academic medical center in the United Arab Emirates (UAE) accredited by the Accreditation Council for Graduate Medical Education-International (ACGME-I) were surveyed between May and June 2014. The authors analysed responses using inductive qualitative thematic analysis to identify emergent themes. Seventy-eight of 96 applicants (81%) completed the survey. The vast majority of respondents 74 (95%) reported that ACGME-I accreditation was an important factor in selecting a residency program. Five major themes were identified, namely improving the quality of education, increasing opportunities, meeting high international standards, improving program structure, and improving patient care. Seven (10%) of respondents felt they would be in a position to pursue fellowship training or future employment in the United States upon graduation from an ACGME-I program. UAE trainees have an overwhelmingly positive perception of international accreditation, with an emphasis on improving the quality of training provided. Misperceptions, however, exist about potential opportunities available to graduates of ACGME-I programs. As more countries adopt the standards of the ACGME-I or other international accrediting bodies, it is important to recognize and foster trainee "buy-in" of educational reform initiatives.

  19. Development and application of the analyzer-based imaging technique with hard synchrotron radiation

    International Nuclear Information System (INIS)

    Coan, P.

    2006-07-01

    The objective of this thesis is twofold: from one side the application of the analyser-based X-ray phase contrast imaging to study cartilage, bone and bone implants using ESRF synchrotron radiation sources and on the other to contribute to the development of the phase contrast techniques from the theoretical and experimental point of view. Several human samples have been studied in vitro using the analyser based imaging (ABI) technique. Examination included projection and computed tomography imaging and 3-dimensional volume rendering of hip, big toe and ankle articular joints. X-ray ABI images have been critically compared with those obtained with conventional techniques, including radiography, computed tomography, ultrasound, magnetic resonance and histology, the latter taken as gold standard. Results show that only ABI imaging was able to either visualize or correctly estimate the early pathological status of the cartilage. The status of the bone ingrowth in sheep implants have also been examined in vitro: ABI images permitted to correctly distinguish between good and incomplete bone healing. Pioneering in-vivo ABI on guinea pigs were also successfully performed, confirming the possible use of the technique to follow up the progression of joint diseases, the bone/metal ingrowth and the efficacy of drugs treatments. As part of the development of the phase contrast techniques, two objectives have been reached. First, it has been experimentally demonstrated for the first time that the ABI and the propagation based imaging (PBI) can be combined to create images with original features (hybrid imaging, HI). Secondly, it has been proposed and experimentally tested a new simplified set-up capable to produce images with properties similar to those obtained with the ABI technique or HI. Finally, both the ABI and the HI have been theoretically studied with an innovative, wave-based simulation program, which was able to correctly reproduce experimental results. (author)

  20. Nonlinear Ultrasonic Techniques to Monitor Radiation Damage in RPV and Internal Components

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Laurence [Georgia Inst. of Technology, Atlanta, GA (United States); Kim, Jin-Yeon [Georgia Inst. of Technology, Atlanta, GA (United States); Qu, Jisnmin [Northwestern Univ., Evanston, IL (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wall, Joe [Electric Power Research Inst. (EPRI), Knoxville, TN (United States)

    2015-11-02

    The objective of this research is to demonstrate that nonlinear ultrasonics (NLU) can be used to directly and quantitatively measure the remaining life in radiation damaged reactor pressure vessel (RPV) and internal components. Specific damage types to be monitored are irradiation embrittlement and irradiation assisted stress corrosion cracking (IASCC). Our vision is to develop a technique that allows operators to assess damage by making a limited number of NLU measurements in strategically selected critical reactor components during regularly scheduled outages. This measured data can then be used to determine the current condition of these key components, from which remaining useful life can be predicted. Methods to unambiguously characterize radiation related damage in reactor internals and RPVs remain elusive. NLU technology has demonstrated great potential to be used as a material sensor – a sensor that can continuously monitor a material’s damage state. The physical effect being monitored by NLU is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave. The degree of nonlinearity is quantified with the acoustic nonlinearity parameter, β, which is an absolute, measurable material constant. Recent research has demonstrated that nonlinear ultrasound can be used to characterize material state and changes in microscale characteristics such as internal stress states, precipitate formation and dislocation densities. Radiation damage reduces the fracture toughness of RPV steels and internals, and can leave them susceptible to IASCC, which may in turn limit the lifetimes of some operating reactors. The ability to characterize radiation damage in the RPV and internals will enable nuclear operators to set operation time thresholds for vessels and prescribe and schedule replacement activities for core internals. Such a capability will allow a more clear definition of reactor safety margins. The research consists of three tasks: (1

  1. Nonlinear Ultrasonic Techniques to Monitor Radiation Damage in RPV and Internal Components

    International Nuclear Information System (INIS)

    Jacobs, Laurence; Kim, Jin-Yeon; Qu, Jisnmin; Ramuhalli, Pradeep; Wall, Joe

    2015-01-01

    The objective of this research is to demonstrate that nonlinear ultrasonics (NLU) can be used to directly and quantitatively measure the remaining life in radiation damaged reactor pressure vessel (RPV) and internal components. Specific damage types to be monitored are irradiation embrittlement and irradiation assisted stress corrosion cracking (IASCC). Our vision is to develop a technique that allows operators to assess damage by making a limited number of NLU measurements in strategically selected critical reactor components during regularly scheduled outages. This measured data can then be used to determine the current condition of these key components, from which remaining useful life can be predicted. Methods to unambiguously characterize radiation related damage in reactor internals and RPVs remain elusive. NLU technology has demonstrated great potential to be used as a material sensor - a sensor that can continuously monitor a material's damage state. The physical effect being monitored by NLU is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave. The degree of nonlinearity is quantified with the acoustic nonlinearity parameter, β, which is an absolute, measurable material constant. Recent research has demonstrated that nonlinear ultrasound can be used to characterize material state and changes in microscale characteristics such as internal stress states, precipitate formation and dislocation densities. Radiation damage reduces the fracture toughness of RPV steels and internals, and can leave them susceptible to IASCC, which may in turn limit the lifetimes of some operating reactors. The ability to characterize radiation damage in the RPV and internals will enable nuclear operators to set operation time thresholds for vessels and prescribe and schedule replacement activities for core internals. Such a capability will allow a more clear definition of reactor safety margins. The research consists of three tasks

  2. The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer

    International Nuclear Information System (INIS)

    Wu, Q. Jackie; Thongphiew, Danthai; Wang Zhiheng; Chankong, Vira; Yin Fangfang

    2008-01-01

    Stereotactic body radiation therapy (SBRT), which delivers a much higher fractional dose than conventional treatment in only a few fractions, is an effective treatment for liver metastases. For patients who are treated under free-breathing conditions, however, respiration-induced tumor motion in the liver is a concern. Limited clinical information is available related to the impact of tumor motion and treatment technique on the dosimetric consequences. This study evaluated the dosimetric deviations between planned and delivered SBRT dose in the presence of tumor motion for three delivery techniques: three-dimensional conformal static beams (3DCRT), dynamic conformal arc (DARC), and intensity-modulated radiation therapy (IMRT). Five cases treated with SBRT for liver metastases were included in the study, with tumor motions ranging from 0.5 to 1.75 cm. For each case, three different treatment plans were developed using 3DCRT, DARC, and IMRT. The gantry/multileaf collimator (MLC) motion in the DARC plans and the MLC motion in the IMRT plans were synchronized to the patient's respiratory motion. Retrospectively sorted four-dimensional computed tomography image sets were used to determine patient-organ motion and to calculate the dose delivered during each respiratory phase. Deformable registration, using thin-plate-spline models, was performed to encode the tumor motion and deformation and to register the dose-per-phase to the reference phase images. The different dose distributions resulting from the different delivery techniques and motion ranges were compared to assess the effect of organ motion on dose delivery. Voxel dose variations occurred mostly in the high gradient regions, typically between the target volume and normal tissues, with a maximum variation up to 20%. The greatest CTV variation of all the plans was seen in the IMRT technique with the largest motion range (D99: -8.9%, D95: -8.3%, and D90: -6.3%). The greatest variation for all 3DCRT plans was less

  3. Larynx-sparing techniques using intensity-modulated radiation therapy for oropharyngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bar Ad, Voichita, E-mail: voichita.bar-ad@jeffersonhospital.org [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Lin, Haibo [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Hwang, Wei-Ting [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, PA (United States); Deville, Curtiland [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Dutta, Pinaki R. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, PA (United States); Tochner, Zelig; Both, Stefan [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States)

    2012-01-01

    The purpose of the current study was to explore whether the laryngeal dose can be reduced by using 2 intensity-modulated radiation therapy (IMRT) techniques: whole-neck field IMRT technique (WF-IMRT) vs. junctioned IMRT (J-IMRT). The effect on planning target volumes (PTVs) coverage and laryngeal sparing was evaluated. WF-IMRT technique consisted of a single IMRT plan, including the primary tumor and the superior and inferior neck to the level of the clavicular heads. The larynx was defined as an organ at risk extending superiorly to cover the arytenoid cartilages and inferiorly to include the cricoid cartilage. The J-IMRT technique consisted of an IMRT plan for the primary tumor and the superior neck, matched to conventional antero-posterior opposing lower neck fields at the level of the thyroid notch. A central block was used for the anterior lower neck field at the level of the larynx to restrict the dose to the larynx. Ten oropharyngeal cancer cases were analyzed. Both the primary site and bilateral regional lymphatics were included in the radiotherapy targets. The averaged V95 for the PTV57.6 was 99.2% for the WF-IMRT technique compared with 97.4% (p = 0.02) for J-IMRT. The averaged V95 for the PTV64 was 99.9% for the WF-IMRT technique compared with 98.9% (p = 0.02) for J-IMRT and the averaged V95 for the PT70 was 100.0% for WF-IMRT technique compared with 99.5% (p = 0.04) for J-IMRT. The averaged mean laryngeal dose was 18 Gy with both techniques. The averaged mean doses within the matchline volumes were 69.3 Gy for WF-MRT and 66.2 Gy for J-IMRT (p = 0.03). The WF-IMRT technique appears to offer an optimal coverage of the target volumes and a mean dose to the larynx similar with J-IMRT and should be further evaluated in clinical trials.

  4. Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique

    International Nuclear Information System (INIS)

    Pinto, Teresa Cristina Nathan Outeiro

    2010-01-01

    A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al 2 O 3 :C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al 2 O 3 :C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al-2O 3 :C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation. (author)

  5. Prediction of UV spectra and UV-radiation damage in actual plasma etching processes using on-wafer monitoring technique

    International Nuclear Information System (INIS)

    Jinnai, Butsurin; Fukuda, Seiichi; Ohtake, Hiroto; Samukawa, Seiji

    2010-01-01

    UV radiation during plasma processing affects the surface of materials. Nevertheless, the interaction of UV photons with surface is not clearly understood because of the difficulty in monitoring photons during plasma processing. For this purpose, we have previously proposed an on-wafer monitoring technique for UV photons. For this study, using the combination of this on-wafer monitoring technique and a neural network, we established a relationship between the data obtained from the on-wafer monitoring technique and UV spectra. Also, we obtained absolute intensities of UV radiation by calibrating arbitrary units of UV intensity with a 126 nm excimer lamp. As a result, UV spectra and their absolute intensities could be predicted with the on-wafer monitoring. Furthermore, we developed a prediction system with the on-wafer monitoring technique to simulate UV-radiation damage in dielectric films during plasma etching. UV-induced damage in SiOC films was predicted in this study. Our prediction results of damage in SiOC films shows that UV spectra and their absolute intensities are the key cause of damage in SiOC films. In addition, UV-radiation damage in SiOC films strongly depends on the geometry of the etching structure. The on-wafer monitoring technique should be useful in understanding the interaction of UV radiation with surface and in optimizing plasma processing by controlling UV radiation.

  6. Simplified field-in-field technique for a large-scale implementation in breast radiation treatment

    International Nuclear Information System (INIS)

    Fournier-Bidoz, Nathalie; Kirova, Youlia M.; Campana, Francois; Dendale, Rémi; Fourquet, Alain

    2012-01-01

    We wanted to evaluate a simplified “field-in-field” technique (SFF) that was implemented in our department of Radiation Oncology for breast treatment. This study evaluated 15 consecutive patients treated with a simplified field in field technique after breast-conserving surgery for early-stage breast cancer. Radiotherapy consisted of whole-breast irradiation to the total dose of 50 Gy in 25 fractions, and a boost of 16 Gy in 8 fractions to the tumor bed. We compared dosimetric outcomes of SFF to state-of-the-art electronic surface compensation (ESC) with dynamic leaves. An analysis of early skin toxicity of a population of 15 patients was performed. The median volume receiving at least 95% of the prescribed dose was 763 mL (range, 347–1472) for SFF vs. 779 mL (range, 349–1494) for ESC. The median residual 107% isodose was 0.1 mL (range, 0–63) for SFF and 1.9 mL (range, 0–57) for ESC. Monitor units were on average 25% higher in ESC plans compared with SFF. No patient treated with SFF had acute side effects superior to grade 1-NCI scale. SFF created homogenous 3D dose distributions equivalent to electronic surface compensation with dynamic leaves. It allowed the integration of a forward planned concomitant tumor bed boost as an additional multileaf collimator subfield of the tangential fields. Compared with electronic surface compensation with dynamic leaves, shorter treatment times allowed better radiation protection to the patient. Low-grade acute toxicity evaluated weekly during treatment and 2 months after treatment completion justified the pursuit of this technique for all breast patients in our department.

  7. Photoselective Vaporisation of the Bladder for the Management of Radiation Cystitis - Technique and Initial Outcomes.

    Science.gov (United States)

    Pascoe, Claire; Christidis, Daniel; Manning, Todd; Lamb, Benjamin W; Murphy, Declan G; Lawrentschuk, Nathan

    2018-05-16

    Objective To describe our technique utilising photoselective vaporisation of the bladder (PVB) for the management of haemorrhagic cystitis and initial results of 12 patients. Materials and Method An audit of theatre records of a single surgeon was performed to identify patients who had undergone PVB for management of radiation-cystitis. Rigid cystoscopy was performed. Ureteric catheters were placed and active bleeding sites targeted to optimise vision. Ablation was commenced using the vaporize function. When lasering around delicate structures the coagulation function was used. Ureteric catheters remained in situ for 24h. An 18Fr Foley catheter was placed. When urine output was clear continuous bladder irrigation was ceased. Both uretetric catheters and Foley catheter were removed prior to the 24hour mark. Results 12 patients were identified. 8 had previously required blood transfusion secondary to bladder haemorrhage. 9 were successfully treated and 2 saw improvement in haematuria but required a repeat procedure at 3 weeks post operatively. 4 went on to receive hyperbaric oxygenation as consolidative therapy. 1 patient was unsuccessfully treated and went on to cystectomy. There were no mortalities. No patients sustained bladder perforation or damage to surrounding structures. Conclusion Radiation cystitis can be life threatening and remains a challenge for the urologist with traditional intra-vescical treatments such as aluminium or formalin having variable results. We present an alternate technique using PVB to ablate the bladder mucosa, with good results. Consolidation with hyperbaric oxygen therapy may be considered. Our study is limited by small sample size and the presence of bilateral ureteric catheters leaving the bladder free from urine may impact immediate post operative outcomes. These initial results are promising however further prospective evaluation with a larger cohort and pre and post operative cystograms would enable better evaluation of this

  8. Investigation research on improvement of safe handling techniques of radiation in medical fields; Reduction of exposure to medical radiation

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Minoru; Watabe, Makoto; Oono, Kuniko [Tokyo Metropolitan Isotope Research Center (Japan)

    1990-01-01

    Today, it is generally recognized that radiation exposure regardless of its use should be limited to the required minimum. The form of radiation utilization for medical treatment is extremely diverse, and to clarify the actual state of dose that doctors, radiation technicians, nurses and subjects as patients receive by the diagnosis and treatment accompanied by radiation exposure is not only indispensable for evaluating the risk they receive, but also to give the important data for pursuing the reduction of radiation exposure dose of those engaging in medical treatment and patients-subjects. In this investigation research, the actual state of radiation exposure in doctors, radiation technicians, nurses and patients or subjects was investigated, and the radiation exposure dose was measured, in this way the reduction of radiation exposure dose was attempted. The radiation exposure dose in one month was 10.8{+-}3.0 mrem in doctors, 10.4{+-}2.5 mrem in radiation technicians, and 6.3{+-}2.5 mrem in nurses. The risk coefficient in a specific medical university was 1155 men-rem. Also the case of nuclear medical diagnosis administering Ga-67 was measured. (K.I.).

  9. Impact of radiation technique upon the outcome of treatment for medulloblastoma

    International Nuclear Information System (INIS)

    Halperin, Edward C.

    1996-01-01

    Craniospinal irradiation (CSI) is an essential component of the therapy of medulloblastoma. Because medulloblastoma disseminates via the cerebrospinal fluid (CSF), CSI technique involves the irradiation of all CSF-bearing areas which are at risk for tumor seeding. Underdosing with radiation because of inadequacies in CSI technique will produce dose 'cold spots' which have the potential of serving as a nidus for tumor recurrence. A simple mathematic model of subclinical disease in medulloblastoma based on the available data concerning the radiosensitivity of medulloblastoma cell lines as well as the known clinical dose-response relationships support the hypothesis that for most cases of medulloblastoma, the radiotherapist is working in a range of doses arrayed on the steep portion of the tumor control probability curve. Underdosing of CSF-bearing areas because of technical problems at the junction of the cranial and spinal fields of irradiation, placement of shielding blocks in the cribiform plate-sub frontal region, and/or anatomic errors in the design of the caudal end of the CSI fields may lead to significant risks of tumor relapse. One may debate the necessity of a posterior fossa boost encompassing the entire anatomic posterior fossa rather than the primary tumor volume with a margin. This review critically evaluates the potential impact of CSI technique upon the outcome of treatment for medulloblastoma, and suggests future areas of inquiry

  10. CDC/NACCHO Accreditation Support Initiative: advancing readiness for local and tribal health department accreditation.

    Science.gov (United States)

    Monteiro, Erinn; Fisher, Jessica Solomon; Daub, Teresa; Zamperetti, Michelle Chuk

    2014-01-01

    Health departments have various unique needs that must be addressed in preparing for national accreditation. These needs require time and resources, shortages that many health departments face. The Accreditation Support Initiative's goal was to test the assumption that even small amounts of dedicated funding can help health departments make important progress in their readiness to apply for and achieve accreditation. Participating sites' scopes of work were unique to the needs of each site and based on the proposed activities outlined in their applications. Deliverables and various sources of data were collected from sites throughout the project period (December 2011-May 2012). Awardees included 1 tribal and 12 local health departments, as well as 5 organizations supporting the readiness of local and tribal health departments. Sites dedicated their funding toward staff time, accreditation fees, completion of documentation, and other accreditation readiness needs and produced a number of deliverables and example documents. All sites indicated that they made accreditation readiness gains that would not have occurred without this funding. Preliminary evaluation data from the first year of the Accreditation Support Initiative indicate that flexible funding arrangements may be an effective way to increase health departments' accreditation readiness.

  11. Proposed Accreditation Standards for Degree-Granting Correspondence Programs Offered by Accredited Institutions.

    Science.gov (United States)

    McGraw-Hill Continuing Education Center, Washington, DC.

    A study on proposed accreditation standards grew out of a need to (1) stimulate the growth of quality correspondence degree programs; and (2) provide a policy for accreditation of correspondence degree programs so that graduates would be encouraged to pursue advanced degree programs offered elsewhere by educational institutions. The study focused…

  12. Accreditation Outcome Scores: Teacher Attitudes toward the Accreditation Process and Professional Development

    Science.gov (United States)

    Ulmer, Phillip Gregory

    2015-01-01

    Accreditation is an essential component in the history of education in the United States and is a central catalyst for quality education, continuous improvement, and positive growth in student achievement. Although previous researchers identified teachers as an essential component in meeting accreditation outcomes, additional information was…

  13. IS 2010 and ABET Accreditation: An Analysis of ABET-Accredited Information Systems Programs

    Science.gov (United States)

    Saulnier, Bruce; White, Bruce

    2011-01-01

    Many strong forces are converging on information systems academic departments. Among these forces are quality considerations, accreditation, curriculum models, declining/steady student enrollments, and keeping current with respect to emerging technologies and trends. ABET, formerly the Accrediting Board for Engineering and Technology, is at…

  14. 42 CFR 8.13 - Revocation of accreditation and accreditation body approval.

    Science.gov (United States)

    2010-10-01

    ... GENERAL PROVISIONS CERTIFICATION OF OPIOID TREATMENT PROGRAMS Certification and Treatment Standards § 8.13... period of 1 year after the date of withdrawal of approval of the accreditation body, unless SAMHSA.... (2) Within 1 year from the date of withdrawal of approval of an accreditation body, or within any...

  15. Adjuvant radiation therapy for bladder cancer: A dosimetric comparison of techniques

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Brian C.; Noa, Kate [Department of Radiation Oncology at the University of Pennsylvania, Philadelphia, PA (United States); Wileyto, E. Paul [Department of Biostatistics and Epidemiology at the University of Pennsylvania, Philadelphia, PA (United States); Bekelman, Justin E. [Department of Radiation Oncology at the University of Pennsylvania, Philadelphia, PA (United States); Deville, Curtiland [Department of Radiation Oncology and Molecular Radiation Sciences at Johns Hopkins University School of Medicine, Baltimore, MD (United States); Vapiwala, Neha; Kirk, Maura; Both, Stefan; Dolney, Derek; Kassaee, Ali [Department of Radiation Oncology at the University of Pennsylvania, Philadelphia, PA (United States); Christodouleas, John P., E-mail: christojo@uphs.upenn.edu [Department of Radiation Oncology at the University of Pennsylvania, Philadelphia, PA (United States)

    2015-01-01

    Trials of adjuvant radiation after cystectomy are under development. There are no studies comparing radiation techniques to inform trial design. This study assesses the effect on bowel and rectal dose of 3 different modalities treating 2 proposed alternative clinical target volumes (CTVs). Contours of the bowel, rectum, CTV-pelvic sidewall (common/internal/external iliac and obturator nodes), and CTV-comprehensive (CTV-pelvic sidewall plus cystectomy bed and presacral regions) were drawn on simulation images of 7 post-cystectomy patients. We optimized 3-dimensional conformal radiation (3-D), intensity-modulated radiation (IMRT), and single-field uniform dose (SFUD) scanning proton plans for each CTV. Mixed models regression was used to compare plans for bowel and rectal volumes exposed to 35% (V{sub 35%}), 65% (V{sub 65%}), and 95% (V{sub 95%}) of the prescribed dose. For any given treatment modality, treating the larger CTV-comprehensive volume compared with treating only the CTV-pelvic sidewall nodes significantly increased rectal dose (V{sub 35%} {sub rectum}, V{sub 65%} {sub rectum}, and V{sub 95%} {sub rectum}; p < 0.001 for all comparisons), but it did not produce significant differences in bowel dose (V{sub 95%} {sub bowel}, V{sub 65%} {sub bowel}, or V{sub 35%} {sub bowel}). The 3-D plans, compared with both the IMRT and the SFUD plans, had a significantly greater V{sub 65%} {sub bowel} and V{sub 95%} {sub bowel} for each proposed CTV (p < 0.001 for all comparisons). The effect of treatment modality on rectal dosimetry differed by CTV, but it generally favored the IMRT and the SFUD plans over the 3-D plans. Comparison of the IMRT plan vs the SFUD plan yielded mixed results with no consistent advantage for the SFUD plan over the IMRT plan. Targeting a CTV that spares the cystectomy bed and presacral region may marginally improve rectal toxicity but would not be expected to improve the bowel toxicity associated with any given modality of adjuvant radiation

  16. Ionizing radiation effects in Acai oil analysed by gas chromatography coupled to mass spectrometry technique

    International Nuclear Information System (INIS)

    Valli, Felipe; Fernandes, Carlos Eduardo; Moura, Sergio; Machado, Ana Carolina; Furasawa, Helio Akira; Pires, Maria Aparecida Faustino; Bustillos, Oscar Vega

    2007-01-01

    The Acai fruit is a well know Brazilian seed plant used in large scale as a source of feed stock, specially in the Brazilian North-east region. The Acai oil is use in many purposes from fuel sources to medicine. The scope of this paper is to analyzed the chemical structures modification of the acai oil after the ionizing radiation. The radiation were set in the range of 10 to 25 kGy in the extracted Acai oil. The analyses were made by gas chromatography coupled to mass spectrometry techniques. A GC/MS Shimatzu QP-5000 equipped with 30 meters DB-5 capillary column with internal diameter of 0.25 mm and 0.25 μm film thickness was used. Helium was used as carried gas and gave a column head pressure of 12 p.s.i. (1 p.s.i. = 6894.76 Pa) and an average flux of 1 ml/min. The temperature program for the GC column consisted of a 4-minutes hold at 75 deg C, a 15 deg C /min ramp to 200 deg C, 8 minutes isothermal. 20 deg C/min ramp to 250 deg C, 2 minutes isothermal. The extraction of the fatty acids was based on liquid-liquid method using chloroform as solvent. The chromatograms resulted shows the presences of the oleic acid and others fatty acids identify by the mass spectra library (NIST-92). The ionization radiation deplete the fatty acids presents in the Acai oil. Details on the chemical qualitative analytical is present as well in this work. (author)

  17. In vitro technique for selection of radiation induced mutants of garlic

    International Nuclear Information System (INIS)

    Zhen, H.R.

    2001-01-01

    In vitro culture and radiation techniques were used for obtaining mutants tolerant to high temperature stress in garlic. Callus cultures and globular bodies were initiated from young leaves on MS medium containing 500 mg/l casein hydrolysate, 1000 mg/l yeast extract and 2mg/l 2,4-D. Globular bodies, resembling compact nodular calli, were irradiated with 5 to 10 Gy gamma rays. Plants and roots were obtained from globular bodies cultured on MS medium containing 2mg/l kinetin and 0.5 mg/l IAA. The plants produced bulblets (small bulbs) when cultured on MS medium containing IBA 2 mg/l and maintained at 32 deg. C. (author)

  18. Preliminary study of human breast tissue using synchrotron radiation combining WAXS and SAXS techniques

    International Nuclear Information System (INIS)

    Conceicao, A.L.C.; Antoniassi, M.; Poletti, M.E.; Caldas, L.V.E.

    2010-01-01

    Using synchrotron radiation, we combined simultaneously wide angle X-ray scattering (WAXS) and small angle X-ray scattering (SAXS) techniques to obtain the scattering profiles of normal and neoplastic breast tissues samples at the momentum transfer range 6.28 nm -1 ≤Q(=4π.sin(θ/2)/λ)≤50.26 nm -1 and 0.15 nm -1 ≤Q≤1.90 nm -1 , respectively. The results obtained show considerable differences between the scattering profiles of these tissues. We verified that the combination of some parameters (ratio between glandular and adipose peak intensity and third-order axial peak intensity) extracted from scattering profiles can be used for identifying breast cancer.

  19. Radiation dose optimization research: Exposure technique approaches in CR imaging – A literature review

    International Nuclear Information System (INIS)

    Seeram, Euclid; Davidson, Rob; Bushong, Stewart; Swan, Hans

    2013-01-01

    The purpose of this paper is to review the literature on exposure technique approaches in Computed Radiography (CR) imaging as a means of radiation dose optimization in CR imaging. Specifically the review assessed three approaches: optimization of kVp; optimization of mAs; and optimization of the Exposure Indicator (EI) in practice. Only papers dating back to 2005 were described in this review. The major themes, patterns, and common findings from the literature reviewed showed that important features are related to radiation dose management strategies for digital radiography include identification of the EI as a dose control mechanism and as a “surrogate for dose management”. In addition the use of the EI has been viewed as an opportunity for dose optimization. Furthermore optimization research has focussed mainly on optimizing the kVp in CR imaging as a means of implementing the ALARA philosophy, and studies have concentrated on mainly chest imaging using different CR systems such as those commercially available from Fuji, Agfa, Kodak, and Konica-Minolta. These studies have produced “conflicting results”. In addition, a common pattern was the use of automatic exposure control (AEC) and the measurement of constant effective dose, and the use of a dose-area product (DAP) meter

  20. Radiation-grafted hydrogels for biomaterial applications as studied by the ESCA technique

    International Nuclear Information System (INIS)

    Ratner, B.D.; Weathersby, P.K.; Hoffman, A.S.; Kelly, M.A.; Schrapen, L.H.

    1978-01-01

    Electron spectroscopy for chemical analysis (ESCA) was used to study the surface composition of several radiation-grafted polymers in both the dry and hydrated (frozen at 160 0 K) states. Poly(2-hydroxyethyl methacrylate) (HEMA) and polyacrylamide, both hydrophilic polymers, were readily detected in the hydrated or dehydrated states when grafted to polethylene substrates. For silicone rubber substrates, both grafts were observed on the hydrated surface but were significantly decreased in surface concentration upon dehydration. For grafts on a polyester-urethane, acrylamide was not a major constituent of either the dry or hydrated surface, while HEMA appeared to increase in abundance upon drying. The amount of the hydrophobic poly(ethyl methacrylate) found on the graft surface depended upon the substrate polymer used, but the surface abundance of poly(ethyl methacrylate) was not affected by drying. These results were considered in terms of polar group orientation, polymer chain mobility, substrate permeability, and the limitations of the ESCA technique. The implications of these results with respect to the use of radiation-grafted hydrophilic polymers for biomedical applications are also discussed

  1. White matter tract-specific quantitative analysis in multiple sclerosis: Comparison of optic radiation reconstruction techniques.

    Directory of Open Access Journals (Sweden)

    Chenyu Wang

    Full Text Available The posterior visual pathway is commonly affected by multiple sclerosis (MS pathology that results in measurable clinical and electrophysiological impairment. Due to its highly structured retinotopic mapping, the visual pathway represents an ideal substrate for investigating patho-mechanisms in MS. Therefore, a reliable and robust imaging segmentation method for in-vivo delineation of the optic radiations (OR is needed. However, diffusion-based tractography approaches, which are typically used for OR segmentation are confounded by the presence of focal white matter lesions. Current solutions require complex acquisition paradigms and demand expert image analysis, limiting application in both clinical trials and clinical practice. In the current study, using data acquired in a clinical setting on a 3T scanner, we optimised and compared two approaches for optic radiation (OR reconstruction: individual probabilistic tractography-based and template-based methods. OR segmentation results were applied to subjects with MS and volumetric and diffusivity parameters were compared between OR segmentation techniques. Despite differences in reconstructed OR volumes, both OR lesion volume and OR diffusivity measurements in MS subjects were highly comparable using optimised probabilistic tractography-based, and template-based, methods. The choice of OR reconstruction technique should be determined primarily by the research question and the nature of the available dataset. Template-based approaches are particularly suited to the semi-automated analysis of large image datasets and have utility even in the absence of dMRI acquisitions. Individual tractography methods, while more complex than template based OR reconstruction, permit measurement of diffusivity changes along fibre bundles that are affected by specific MS lesions or other focal pathologies.

  2. Development of Ultraviolet (UV) Radiation Protective Fabric Using Combined Electrospinning and Electrospraying Technique

    Science.gov (United States)

    Sinha, Mukesh Kumar; Das, B. R.; Kumar, Kamal; Kishore, Brij; Prasad, N. Eswara

    2017-06-01

    The article reports a novel technique for functionization of nanoweb to develop ultraviolet (UV) radiation protective fabric. UV radiation protection effect is produced by combination of electrospinning and electrospraying technique. A nanofibrous web of polyvinylidene difluoride (PVDF) coated on polypropylene nonwoven fabric is produced by latest nanospider technology. Subsequently, web is functionalized by titanium dioxide (TiO2). The developed web is characterized for evaluation of surface morphology and other functional properties; mechanical, chemical, crystalline and thermal. An optimal (judicious) nanofibre spinning condition is achieved and established. The produced web is uniformly coated by defect free functional nanofibres in a continuous form of useable textile structural membrane for ultraviolet (UV) protective clothing. This research initiative succeeds in preparation and optimization of various nanowebs for UV protection. Field Emission Scanning Electron Microscope (FESEM) result reveals that PVDF webs photo-degradative behavior is non-accelerated, as compared to normal polymeric grade fibres. Functionalization with TiO2 has enhanced the photo-stability of webs. The ultraviolet protection factor of functionalized and non-functionalized nanowebs empirically evaluated to be 65 and 24 respectively. The developed coated layer could be exploited for developing various defence, para-military and civilian UV protective light weight clothing (tent, covers and shelter segments, combat suit, snow bound camouflaging nets). This research therefore, is conducted in an attempt to develop a scientific understanding of PVDF fibre coated webs for photo-degradation and applications for defence protective textiles. This technological research in laboratory scale could be translated into bulk productionization.

  3. A snapshot of radiation therapy techniques and technology in Queensland: An aid to mapping undergraduate curriculum

    International Nuclear Information System (INIS)

    Bridge, Pete; Carmichael, Mary-Ann; Brady, Carole; Dry, Allison

    2013-01-01

    Undergraduate students studying the Bachelor of Radiation Therapy at Queensland University of Technology (QUT) attend clinical placements in a number of department sites across Queensland. To ensure that the curriculum prepares students for the most common treatments and current techniques in use in these departments, a curriculum matching exercise was performed. A cross-sectional census was performed on a pre-determined “Snapshot” date in 2012. This was undertaken by the clinical education staff in each department who used a standardized proforma to count the number of patients as well as prescription, equipment, and technique data for a list of tumour site categories. This information was combined into aggregate anonymized data. All 12 Queensland radiation therapy clinical sites participated in the Snapshot data collection exercise to produce a comprehensive overview of clinical practice on the chosen day. A total of 59 different tumour sites were treated on the chosen day and as expected the most common treatment sites were prostate and breast, comprising 46% of patients treated. Data analysis also indicated that intensity-modulated radiotherapy (IMRT) use is relatively high with 19.6% of patients receiving IMRT treatment on the chosen day. Both IMRT and image-guided radiotherapy (IGRT) indications matched recommendations from the evidence. The Snapshot method proved to be a feasible and efficient method of gathering useful data to inform curriculum matching. Frequency of IMRT use in Queensland matches or possibly exceeds that indicated in the literature. It is recommended that future repetition of the study be undertaken in order to monitor trends in referral patterns and new technology implementation

  4. A snapshot of radiation therapy techniques and technology in Queensland: An aid to mapping undergraduate curriculum

    Energy Technology Data Exchange (ETDEWEB)

    Bridge, Pete; Carmichael, Mary-Ann [School of Clinical Sciences, Queensland University of Technology, Brisbane, Queensland, 4001 (Australia); Brady, Carole [Radiation Oncology Mater Centre, Raymond Terrace, South Brisbane, Queensland, 4101 (Australia); Dry, Allison [Cancer Care Services Royal Brisbane Women' s Hospital Herston, Brisbane, Queensland, 4029 (Australia); School of Clinical Sciences, Queensland University of Technology, Brisbane, Queensland, 4001 (Australia)

    2013-03-15

    Undergraduate students studying the Bachelor of Radiation Therapy at Queensland University of Technology (QUT) attend clinical placements in a number of department sites across Queensland. To ensure that the curriculum prepares students for the most common treatments and current techniques in use in these departments, a curriculum matching exercise was performed. A cross-sectional census was performed on a pre-determined “Snapshot” date in 2012. This was undertaken by the clinical education staff in each department who used a standardized proforma to count the number of patients as well as prescription, equipment, and technique data for a list of tumour site categories. This information was combined into aggregate anonymized data. All 12 Queensland radiation therapy clinical sites participated in the Snapshot data collection exercise to produce a comprehensive overview of clinical practice on the chosen day. A total of 59 different tumour sites were treated on the chosen day and as expected the most common treatment sites were prostate and breast, comprising 46% of patients treated. Data analysis also indicated that intensity-modulated radiotherapy (IMRT) use is relatively high with 19.6% of patients receiving IMRT treatment on the chosen day. Both IMRT and image-guided radiotherapy (IGRT) indications matched recommendations from the evidence. The Snapshot method proved to be a feasible and efficient method of gathering useful data to inform curriculum matching. Frequency of IMRT use in Queensland matches or possibly exceeds that indicated in the literature. It is recommended that future repetition of the study be undertaken in order to monitor trends in referral patterns and new technology implementation.

  5. Novel Technique for Hepatic Fiducial Marker Placement for Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Jarraya, Hajer; Chalayer, Chloé; Tresch, Emmanuelle; Bonodeau, Francois; Lacornerie, Thomas; Mirabel, Xavier; Boulanger, Thomas; Taieb, Sophie; Kramar, Andrew; Lartigau, Eric; Ceugnart, Luc

    2014-01-01

    Purpose: To report experience with fiducial marker insertion and describe an advantageous, novel technique for fiducial placement in the liver for stereotactic body radiation therapy with respiratory tracking. Methods and Materials: We implanted 1444 fiducials (single: 834; linked: 610) in 328 patients with 424 hepatic lesions. Two methods of implantation were compared: the standard method (631 single fiducials) performed on 153 patients from May 2007 to May 2010, and the cube method (813 fiducials: 610 linked/203 single) applied to 175 patients from April 2010 to March 2013. The standard method involved implanting a single marker at a time. The novel technique entailed implanting 2 pairs of linked markers when possible in a way to occupy the perpendicular edges of a cube containing the tumor inside. Results: Mean duration of the cube method was shorter than the standard method (46 vs 61 minutes; P<.0001). Median numbers of skin and subcapsular entries were significantly smaller with the cube method (2 vs 4, P<.0001, and 2 vs 4, P<.0001, respectively). The rate of overall complications (total, major, and minor) was significantly lower in the cube method group compared with the standard method group (5.7% vs 13.7%; P=.013). Major complications occurred while using single markers only. The success rate was 98.9% for the cube method and 99.3% for the standard method. Conclusions: We propose a new technique of hepatic fiducial implantation that makes use of linked fiducials and involves fewer skin entries and shorter time of implantation. The technique is less complication-prone and is migration-resistant

  6. Lab-Based Measurement of Remediation Techniques for Radiation Portal Monitors (Initial Report)

    International Nuclear Information System (INIS)

    Livesay, Jake

    2012-01-01

    Radiation Portal Monitors (RPM) deployed by the Second Line of Defense (SLD) are known to be sensitive to the natural environmental radioactive background. There are several techniques used to mitigate the effects of background on the monitors, but since the installation environments can vary significantly from one another the need for a standardized, systematic, study of remediation techniques was proposed and carried out. This study is not meant to serve as the absolute last word on the subject. The data collected are, however, intelligible and useful. Some compromises were made, each of which will be described in detail. The hope of this initial report is to familiarize the SLD science teams with ORNL's effort to model the effect of various remediation techniques on simple, static backgrounds. This study provides a good start toward benchmarking the model, and each additional increment of data will serve to make the model more robust. The scope of this initial study is limited to a few basic cases. Its purpose is to prove the utility of lab-based study of remediation techniques and serve as a standard data set for future use. This importance of this first step of standardization will become obvious when science teams are working in parallel on issues of remediation; having a common starting point will do away with one category of difference, thereby making easier the task of determining the sources of disagreement. Further measurements will augment this data set, allowing for further constraint of the universe of possible situations. As will be discussed in the 'Going Forward' section, more data will be included in the final report of this work. Of particular interest will be the data taken with the official TSA lead collimators, which will provide more direct results for comparison with installation data.

  7. Proficiency test in the accreditation system

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.

    2008-01-01

    In the accreditation process of a radioactivity measurements laboratory, according to ISO standard 17025, proficiency tests play a fundamental role. These PTs constitute an irreplaceable tool for the validation of measuring methods. In the case of Spain, ENAC, which is the Spanish accreditation national body, requires that the laboratory has to take part in a PT for each one of the accredited measuring methods in the period of time between two reassessments of the accreditation, what happens every 4-5 years. In specific areas of determination procedures, among which radioactive measurements could be included, the number of methods which can be accredited is very large. The purpose of the present work is to establish a classification into families of the different radioactivity measurement procedures, as well as to establish complementary actions that guarantee that carrying out periodically proficiency-tests on any of the included procedures in each family, every measurement procedure include in that family is controlled, complying with the criteria established by ENAC

  8. The accreditation programs and proficiency test in Taiwan for personnel dosimeter services (1991-1998)

    International Nuclear Information System (INIS)

    Lee, B.T.; Hwang, W.S.; Su, S.H.

    2000-01-01

    According to the ionizing radiation safety regulation approved by the ROC Atomic Energy Council (AEC), personnel dosimeter processors shall be accredited by the Chinese National Laboratory Accreditation (CNLA) program before offering dosimeter services and shall be accredited every two years (now has been rescheduled to be every three years since 1996). The aim of this program is to secure quality and technical capability of personnel dosimeters, and to provide systematic improvement for the internal calibration and testing laboratory applying for accreditation by means of assessment procedures. The criteria used to evaluate the capability at laboratories are ISO/IEC 25 (1990) and technical guide in different accreditation fields. The Institute of Nuclear Energy Research (INER) was entrusted by CNLA as the central laboratory to perform the proficiency test of personnel dosimeters for laboratory accreditation in December 1990. Such proficiency tests, based on ANSI N13.11 (1983), which is mainly separated to accident categories and protection categories which consists of eight parts of tests including single and mixture radiation of x-ray, gamma, beta and neutron, have been conducted four times, in 1991, 1993, 1995 and 1998. This paper deals with the test procedures and results of proficiency tests of personnel dosimeters from 1991 until 1998. The results of the four proficiency tests showed that, for accident categories, the pass rate is about 91%; for protection categories, the pass rate is about 98%. Meanwhile, the central laboratory will adopt a new version of HPS N13.11 (1993) to replace ANSI N13.11 (1983) as new criteria for the next proficiency test to be conducted in 2001. (author)

  9. Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses

    International Nuclear Information System (INIS)

    Huda, Walter; Lieberman, Kristin A.; Chang, Jack; Roskopf, Marsha L.

    2004-01-01

    We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18x7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186±8 mm and 147±8 mm, respectively, with an average HU value of 209±40. An infant head was found to be equivalent to a water cylinder with a radius of ∼60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is ∼20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors

  10. Installations for radiation therapy with remote controlled afterloading technique. Ferngesteuerte Applikationsanlagen zur Therapie mit umschlossenen radioaktiven Stoffen

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    Installations for radiation therapy with remote controlled afterloading technique; radiation protection rules for fabrication and construction; amendment 1 to draft standard (DIN) 6853. Compared to the draft standard of Semptember 1980, the following modifications are planned as amendment 1: a. Paragraph no. 1: In the title, the word ''scope'' is changed into ''field of application''. The words ''by moving the radiation source electromecanically'' are deleted. b. Paragraph no. 2'' Standards also applicable'' and the list of ''Additional standards'' are summarized under the heading ''Standards and supporting documents'' (without any paragraph number). c. Paragraph no. 3 ''Terms'' is completed by additional terms and their definitions.

  11. The use of recombinant DNA techniques to study radiation-induced damage, repair and genetic change in mammalian cells

    International Nuclear Information System (INIS)

    Thacker, J.

    1986-01-01

    A brief introduction is given to appropriate elements of recombinant DNA techniques and applications to problems in radiobiology are reviewed with illustrative detail. Examples are included of studies with both 254 nm ultraviolet light and ionizing radiation and the review progresses from the molecular analysis of DNA damage in vitro through to the nature of consequent cellular responses. The review is dealt with under the following headings: Molecular distribution of DNA damage, The use of DNA-mediated gene transfer to assess damage and repair, The DNA double strand break: use of restriction endonucleases to model radiation damage, Identification and cloning of DNA repair genes, Analysis of radiation-induced genetic change. (UK)

  12. Radiation techniques used in patients with breast cancer: Results of a survey in Spain

    Science.gov (United States)

    Algara, Manuel; Arenas, Meritxell; De las Peñas Eloisa Bayo, Dolores; Muñoz, Julia; Carceller, José Antonio; Salinas, Juan; Moreno, Ferran; Martínez, Francisco; González, Ezequiel; Montero, Ángel

    2012-01-01

    Aim To evaluate the resources and techniques used in the irradiation of patients with breast cancer after lumpectomy or mastectomy and the status of implementation of new techniques and therapeutic schedules in our country. Background The demand for cancer care has increased among the Spanish population, as long as cancer treatment innovations have proliferated. Radiation therapy in breast cancer has evolved exponentially in recent years with the implementation of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, image guided radiotherapy and hypofractionation. Material and Methods An original survey questionnaire was sent to institutions participating in the SEOR-Mama group (GEORM). In total, the standards of practice in 969 patients with breast cancer after surgery were evaluated. Results The response rate was 70% (28/40 centers). In 98.5% of cases 3D conformal treatment was used. All the institutions employed CT-based planning treatment. Boost was performed in 56.4% of patients: electrons in 59.8%, photons in 23.7% and HDR brachytherapy in 8.8%. Fractionation was standard in 93.1% of patients. Supine position was the most frequent. Only 3 centers used prone position. The common organs of risk delimited were: homolateral lung (80.8%) and heart (80.8%). In 84% histograms were used. An 80.8% of the centers used isocentric technique. In 62.5% asymmetric fields were employed. CTV was delimited in 46.2%, PTV in 65% and both in 38.5%. A 65% of the centers checked with portal films. IMRT and hypofractionation were used in 1% and in 5.5% respectively. Conclusion In most of centers, 3D conformal treatment and CT-based planning treatment were used. IMRT and hypofractionation are currently poorly implemented in Spain. PMID:24377012

  13. Accreditation, a tool for business competitiveness

    International Nuclear Information System (INIS)

    Rivera, B.

    2015-01-01

    Conformity Assessment Bodies (laboratories , certification and inspection bodies, etc ) assess conformity of products and services to requirements , usually relating to quality and safety. For their activities to provide due confidence both in national and international markets these bodies must demonstrate to have the relevant technical competence and to perform according to international standards. This confidence is based on the assessments conducted in different countries by the accreditation body in Spain ENAC. Using accredited conformity assessment bodies bodies: risks are minimized; customer confidence is increased; acceptance in foreign countries is enhanced; self-regulation is promoted. (Author)

  14. An Experimental Study for Improving Snake Antivenin Production Using Gamma Radiation and a Biotechnological Technique

    International Nuclear Information System (INIS)

    Mohamed, H.K.

    2015-01-01

    Snake-bite is considered a neglected tropical disease that affects thousands of people worldwide. Administration of antivenom is the corner stone in the therapy of snake-bite. The study aimed to improve the production of antivenom using gamma irradiation to detoxify venom and calcium phosphate nanoparticles as alternative adjuvant. This was carried out by studying the toxicological and immunological properties of the Naja haje venom before and after exposure to 2 KGy gamma radiation. Calcium phosphate nanoparticles were selected to be used as adjuvant as they showed better entrapment efficacy than Alum or chitosan nanoparticles. In order to achieve the goal of the present study, the native, γ irradiated and nanoparticles loaded venom as well nanoparticles loaded irradiated venom were used for preparation of their specific antivenom using rabbits. Data revealed that gamma irradiation of Naja haje venom reduced its lethality to one sixth as compared to its native venom. There was no change in the antigenic reactivity between both native and γ irradiated Naja haje venoms. Inhibition in the phospholipase and proteolytic activities after gamma irradiation were shown. Furthermore, injection of γ irradiated Naja haje venom did not significantly change activities of serum LDH, CPK, CK-MB, ALT and AST as well as urea and creatinine levels compared to the normal group. In addition, the immune response of immunized rabbits was evaluated through determination of antibody titer using ELISA technique, serum titer produced with γ irradiated venom loaded on CPN showed highest titer as compared to other sera. Results indicated that the sooner antivenom was injected the higher the neutralizing capacity obtained. All the prepared antivenoms were able to neutralize the toxicological activities of Naja haje snake venom to same extent. Thus, gamma radiation is a reliable tool for detoxification of Naja haje venom without affecting its immunogenicity. Furthermore. Calcium phosphate

  15. Dosimetry studies with TLDs for stereotactic radiation techniques for intraocular tumours

    International Nuclear Information System (INIS)

    Ertl, A.; Schoeggl, A.; Zehetmayer, M.; Kindl, P.; Hartl, R.

    1997-01-01

    Between March 1993 and January 1997, stereotactic radiation techniques were used to irradiate 66 intraocular tumour patients with the Gamma Knife (Leksell Gamma Knife, model B unit) at the University of Vienna, Austria. This study investigates the dosimetry for stereotactic irradiation of ocular structures. For the dosimetry program KULA 4.4, Gamma Knife stereotactic irradiation of the eye represents an extreme frontal skull position. In addition, irradiation of the eye may be performed in the usual supine position in exceptional cases only. With the patient in the prone position, the dose planning program has to calculate with a significantly large number of single-beam extrapolations. In our first experiment we measured the isocentre dose for eight different γ-angle positions, both in prone and supine positions, using TLD measurements in an Alderson head phantom. We found a maximum deviation of ±1.6% using these individually calibrated TLDs. In the second experiment we examined the dose cross profiles for the two most frequently used treatment positions (supine position, γ = 65 deg., and prone position, γ = 140 deg.). For this purpose we implanted a specially designed TLD array into the orbit of a human cadaver head. We found excellent agreement of the dose values measured for the isocentre as well as the posterior part of the eye with orbit with deviations of less than -2.7%. However, for the anterior part of the eye, deviations between computer-generated calculations and the TLD measurements were found to range up to -30%. These differences were noticed both for supine and prone positions. For the Gamma Knife stereotactic irradiation of ocular tumours or pathologies, precautions should be taken to avoid significant underdosage in the anterior part of the radiation field. (author)

  16. Digital holographic interferometry: A novel optical calorimetry technique for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cavan, Alicia, E-mail: alicia.cavan@cdhb.health.nz [Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand and Christchurch Hospital, Private Bag 4710, Christchurch 8140 (New Zealand); Meyer, Juergen, E-mail: juergen@uw.edu [Department of Radiation Oncology, University of Washington, 1959 Northeast Pacific Street, Box 356043, Seattle, Washington 98195 (United States)

    2014-02-15

    Purpose: To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. Methods: The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. Results: The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ±3.45 Gy (corresponding to an uncertainty in the temperature value of ±8.3 × 10{sup −4} K). The relative dose fall off was in agreement with treatment planning system modeled data. Conclusions: First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10{sup −5} m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

  17. Pathway to Accreditation of Medical laboratories in Mauritius

    African Journals Online (AJOL)

    Nafiisah

    The issue of quality management systems and accreditation is gaining increasing ... MAURITAS is to provide accreditation services to testing/calibration ... carries out its own, internal, audits on a regular basis and record the results for scrutiny ...

  18. Risk of Second Cancers According to Radiation Therapy Technique and Modality in Prostate Cancer Survivors

    Energy Technology Data Exchange (ETDEWEB)

    Berrington de Gonzalez, Amy, E-mail: berringtona@mail.nih.gov [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Wong, Jeannette; Kleinerman, Ruth; Kim, Clara; Morton, Lindsay [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Bekelman, Justin E. [Department of Radiation Oncology, Abramson Cancer Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Center for Clinical Epidemiology and Biostatistics, Department of Biostatistics and Epidemiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Leonard Davis Institute of Health Economics, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2015-02-01

    Purpose: Radiation therapy (RT) techniques for prostate cancer are evolving rapidly, but the impact of these changes on risk of second cancers, which are an uncommon but serious consequence of RT, are uncertain. We conducted a comprehensive assessment of risks of second cancer according to RT technique (>10 MV vs ≤10 MV and 3-dimensional [3D] vs 2D RT) and modality (external beam RT, brachytherapy, and combined modes) in a large cohort of prostate cancer patients. Methods and Materials: The cohort was constructed using the Surveillance Epidemiology and End Results-Medicare database. We included cases of prostate cancer diagnosed in patients 66 to 84 years of age from 1992 to 2004 and followed through 2009. We used Poisson regression analysis to compare rates of second cancer across RT groups with adjustment for age, follow-up, chemotherapy, hormone therapy, and comorbidities. Analyses of second solid cancers were based on the number of 5-year survivors (n=38,733), and analyses of leukemia were based on number of 2-year survivors (n=52,515) to account for the minimum latency period for radiation-related cancer. Results: During an average of 4.4 years' follow-up among 5-year prostate cancer survivors (2DRT = 5.5 years; 3DRT = 3.9 years; and brachytherapy = 2.7 years), 2933 second solid cancers were diagnosed. There were no significant differences in second solid cancer rates overall between 3DRT and 2DRT patients (relative risk [RR] = 1.00, 95% confidence interval [CI]: 0.91-1.09), but second rectal cancer rates were significantly lower after 3DRT (RR = 0.59, 95% CI: 0.40-0.88). Rates of second solid cancers for higher- and lower-energy RT were similar overall (RR = 0.97, 95% CI: 0.89-1.06), as were rates for site-specific cancers. There were significant reductions in colon cancer and leukemia rates in the first decade after brachytherapy compared to those after external beam RT. Conclusions: Advanced treatment planning may have reduced rectal

  19. Radiation dose reduction on multidetector abdominal CT using adaptive statistical iterative reconstruction technique in children

    International Nuclear Information System (INIS)

    Zhang Qifeng; Peng Yun; Duan Xiaomin; Sun Jihang; Yu Tong; Han Zhonglong

    2013-01-01

    Objective: To investigate the feasibility to reduce radiation doses on pediatric multidetector abdominal CT using the adaptive statistical iterative reconstruction technique (ASIR) associated with automated tube current modulation technique (ATCM). Methods: Thirty patients underwent abdominal CT with ATCM and the follow-up scan with ATCM cooperated with 40% ASIR. ATCM was used with age dependent noise index (NI) settings: NI = 9 for 0-5 year old and NI = 11 for > 5 years old for simple ATCM group, NI = 11 for 0-5 year old and NI = 15 for > 5 years old for ATCM cooperated with 40% ASIR group (AISR group). Two radiologists independently evaluated images for diagnostic quality and image noise with subjectively image quality score and image noise score using a 5-point scale. Interobserver agreement was assessed by Kappa test. The volume CT dose indexes (CTDIvol) for the two groups were recorded. Statistical significance for the CTDIvol value was analyzed by pair-sample t test. Results: The average CTDIvol for the ASIR group was (1.38 ± 0.64) mGy, about 60% lower than (3.56 ± 1.23) mGy for the simple ATCM group, and the CTDIvol of two groups had statistically significant differences. (t = 33.483, P < 0.05). The subjective image quality scores for the simple ATCM group were 4.43 ± 0.57 and 4.37 ±0.61, Kappa = 0.878, P < 0.01 (ASIR group: 4.70 ± 0.47 and 4.60 ± 0.50, Kappa = 0.783, P < 0.01), by two observers. The image noise score for the simple ATCM group were 4.03 ±0.56 and 3.83 ±0.53, Kappa = 0.572, P < 0.01 (ASIR group: 4.20 ± 0.48 and 4.10 ± 0.48, Kappa = 0.748, P < 0.01), by two observers. All images had acceptable diagnostic image quality. Conclusion: Lower radiation dose can be achieved by elevating NI with ASIR in pediatric CT abdominal studies, while maintaining diagnostically acceptable images. (authors)

  20. Repeat Whole Brain Radiation Therapy with a Simultaneous Infield Boost: A Novel Technique for Reirradiation

    International Nuclear Information System (INIS)

    Hall, W.A.; Prabhu, R.S.; Crocker, I.R.; Dhabban, A.; Ogunleye, T.; Kandula, Sh.; Jiang, X.; Curran, W.J.; Shu, H.G.

    2014-01-01

    The treatment of patients who experience intracranial progression after whole brain radiation therapy (WBRT) is a clinical challenge. Novel radiation therapy delivery technologies are being applied with the objective of improving tumor and symptom control in these patients. The purpose of this study is to describe the clinical outcomes of the application of a novel technology to deliver repeat WBRT with volume modulated arc therapy (VMAT) and a simultaneous infield boost (WB-SIB) to gross disease. A total of 16 patients were initially treated with WBRT between 2000 and 2008 and then experienced intracranial progression, were treated using repeat WB-SIB, and were analyzed. The median dose for the first course of WBRT was 35 Gy (range: 30–50.4 Gy). Median time between the initial course of WBRT and repeat WB-SIB was 11.3 months. The median dose at reirradiation was 20 Gy to the whole brain with a median boost dose of 30 Gy to gross disease. A total of 2 patients demonstrated radiographic disease progression after treatment. The median overall survival (OS) time from initial diagnosis of brain metastases was 18.9 months (range: 7.1–66.6 (95% CI: 0.8–36.9)). The median OS time after initiation of reirradiation for all patients was 2.7 months (range: 0.46–14.46 (95% CI: 1.3–8.7)). Only 3 patients experienced CTCAE grade 3 fatigue. No other patients experienced any ≥ CTCAE grade 3 toxicity. This analysis reports the result of a novel RT delivery technique for the treatment of patients with recurrent brain metastases. Side effects were manageable and comparable to other conventional repeat WBRT series. Repeat WB-SIB using the VMAT RT delivery technology is feasible and appears to have acceptable short-term acute toxicity. These results may provide a foundation for further exploration of the WB-SIB technique for repeat WBRT in future prospective clinical trials.

  1. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  2. Impact of quality concepts on nuclear engineering accreditation

    International Nuclear Information System (INIS)

    Woodall, D.M.

    1993-01-01

    This paper is an update of the accreditation process for nuclear engineering education at the undergraduate and graduate level in U.S. universities and colleges. The Engineering Accreditation Commission (EAC) of the Accreditation Board for Engineering and Technology (ABET) has made a number of major changes in the process for engineering accreditation in recent years. This paper identifies those changes that have taken place, discusses the rationale for those changes, and encourages U.S. universities with nuclear engineering programs to respond

  3. A technique for estimating the probability of radiation-stimulated failures of integrated microcircuits in low-intensity radiation fields: Application to the Spektr-R spacecraft

    Science.gov (United States)

    Popov, V. D.; Khamidullina, N. M.

    2006-10-01

    In developing radio-electronic devices (RED) of spacecraft operating in the fields of ionizing radiation in space, one of the most important problems is the correct estimation of their radiation tolerance. The “weakest link” in the element base of onboard microelectronic devices under radiation effect is the integrated microcircuits (IMC), especially of large scale (LSI) and very large scale (VLSI) degree of integration. The main characteristic of IMC, which is taken into account when making decisions on using some particular type of IMC in the onboard RED, is the probability of non-failure operation (NFO) at the end of the spacecraft’s lifetime. It should be noted that, until now, the NFO has been calculated only from the reliability characteristics, disregarding the radiation effect. This paper presents the so-called “reliability” approach to determination of radiation tolerance of IMC, which allows one to estimate the probability of non-failure operation of various types of IMC with due account of radiation-stimulated dose failures. The described technique is applied to RED onboard the Spektr-R spacecraft to be launched in 2007.

  4. What Should Gerontology Learn from Health Education Accreditation?

    Science.gov (United States)

    Bradley, Dana Burr; Fitzgerald, Kelly

    2012-01-01

    Quality assurance and accreditation are closely tied together. This article documents the work toward a unified and comprehensive national accreditation program in health education. By exploring the accreditation journey of another discipline, the field of gerontology should learn valuable lessons. These include an attention to inclusivity, a…

  5. Mozambique's journey toward accreditation of the National Tuberculosis Reference Laboratory.

    Science.gov (United States)

    Viegas, Sofia O; Azam, Khalide; Madeira, Carla; Aguiar, Carmen; Dolores, Carolina; Mandlaze, Ana P; Chongo, Patrina; Masamha, Jessina; Cirillo, Daniela M; Jani, Ilesh V; Gudo, Eduardo S

    2017-01-01

    Internationally-accredited laboratories are recognised for their superior test reliability, operational performance, quality management and competence. In a bid to meet international quality standards, the Mozambique National Institute of Health enrolled the National Tuberculosis Reference Laboratory (NTRL) in a continuous quality improvement process towards ISO 15189 accreditation. Here, we describe the road map taken by the NTRL to achieve international accreditation. The NTRL adopted the Strengthening Laboratory Management Toward Accreditation (SLMTA) programme as a strategy to implement a quality management system. After SLMTA, the Mozambique National Institute of Health committed to accelerate the NTRL's process toward accreditation. An action plan was designed to streamline the process. Quality indicators were defined to benchmark progress. Staff were trained to improve performance. Mentorship from an experienced assessor was provided. Fulfilment of accreditation standards was assessed by the Portuguese Accreditation Board. Of the eight laboratories participating in SLMTA, the NTRL was the best-performing laboratory, achieving a 53.6% improvement over the SLMTA baseline conducted in February 2011 to the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) assessment in June 2013. During the accreditation assessment in September 2014, 25 minor nonconformities were identified and addressed. In March 2015, the NTRL received Portuguese Accreditation Board recognition of technical competency for fluorescence smear microscopy, and solid and liquid culture. The NTRL is the first laboratory in Mozambique to achieve ISO 15189 accreditation. From our experience, accreditation was made possible by institutional commitment, strong laboratory leadership, staff motivation, adequate infrastructure and a comprehensive action plan.

  6. Practical Nursing Education: Criteria and Procedures for Accreditation.

    Science.gov (United States)

    National Association for Practical Nurse Education and Service, Inc., New York, NY.

    The third in a series of pamphlets on practical nursing education, this document contains information on accreditation standards governing nursing programs. Included are announcements of: (1) available accreditation and consultation services, (2) policies regulating accreditation eligibility, (3) standards of ethics by which nursing programs are…

  7. Accreditation in the Professions: Implications for Educational Leadership Preparation Programs

    Science.gov (United States)

    Pavlakis, Alexandra; Kelley, Carolyn

    2016-01-01

    Program accreditation is a process based on a set of professional expectations and standards meant to signal competency and credibility. Although accreditation has played an important role in shaping educational leadership preparation programs, recent revisions to accreditation processes and standards have highlighted attention to the purposes,…

  8. 9 CFR 161.3 - Standards for accredited veterinarian duties.

    Science.gov (United States)

    2010-01-01

    ... legally able to practice veterinary medicine. An accredited veterinarian shall perform the functions of an... examine such an animal showing abnormalities, in order to determine whether or not there is clinical... accredited work, an accredited veterinarian shall take such measures of sanitation as are necessary to...

  9. 9 CFR 439.10 - Criteria for obtaining accreditation.

    Science.gov (United States)

    2010-01-01

    ... degree in chemistry, food science, food technology, or a related field. (i) For food chemistry... ACT ACCREDITATION OF NON-FEDERAL CHEMISTRY LABORATORIES § 439.10 Criteria for obtaining accreditation. (a) Analytical laboratories may be accredited for the analyses of food chemistry analytes, as defined...

  10. Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Pradip, Joe; Dinakran, Paul M.; Srikanth, B.

    2010-01-01

    Objectives: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. Materials and Methods: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tube potential of 140 kV; mAs values were automatically selected by the machine. Effective doses were calculated using dose-length product (DLP) values and the image quality was assessed using the signal-to-noise (SNR) ratio values. Mean effective doses using manual protocol for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 8.58 mSv, 8.54 mSv, and 9.07 mSv, respectively. Mean effective doses using z-axis dose modulation for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 4.95 mSv, 6.87 mSv, and 10.24 mSv, respectively. The SNR at the region of the liver for patients of body weight of 40-60 kg was 5.1 H, 6.2 H, and 8.8 H for manual, angular, and z-axis dose modulation, respectively. Conclusion: Dose reduction of up to 15% was achieved using angular dose modulation and of up to 42% using z-axis dose modulation, with acceptable diagnostic image quality compared to the manual protocol. (author)

  11. Ties That Bind: Default, Accreditation, and Articulation.

    Science.gov (United States)

    Prager, Carolyn

    1995-01-01

    Examines changes in the accreditation environment and the resulting implications for the articulation of students from for-profit to not-for-profit institutions such as community colleges. Indicates that the costs of programmatic redundancy and duplication brought about by mission convergence at these institutions will emerge as a major policy…

  12. Quality Development in Healthcare: Participation vs. Accreditation

    DEFF Research Database (Denmark)

    Simonsen, Jesper; Hertzum, Morten; Scheuer, John Damm

    2018-01-01

    and balanced with participatory approaches that allow for local experimentation and implementation of high-quality outcomes. We describe accreditation and participatory design as two approaches to reconfiguring and aligning work organisation and technology; further, we emphasise the differences in each...

  13. Accrediting Professional Education: Research and Policy Issues.

    Science.gov (United States)

    Koff, Robert H.; Florio, David H.

    Research and legal issues that relate to accreditation policy questions for schools, colleges, and departments of education are reviewed, and strategies for integrating empirical information and social/professional values are presented. The discussion divides into three sections: (1) information concerning a variety of contextual issues that…

  14. 42 CFR 423.168 - Accreditation organizations.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Accreditation organizations. 423.168 Section 423.168 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM VOLUNTARY MEDICARE PRESCRIPTION DRUG BENEFIT Cost Control and Quality...

  15. The American Association for Laboratory Accreditation

    Science.gov (United States)

    2011-03-28

    ISO / IEC 17025 ...Information Technology A2LA DoD ELAP Program n All labs are assessed to ISO / IEC 17025 :2005 as the base standard. n In addition, the requirements of 2003...n Inspection Body Accreditation ( ISO / IEC 17020) n Proficiency Testing Providers ( ISO / IEC 17043) n Reference Materials Producers ( ISO Guide

  16. Digital PET compliance to EARL accreditation specifications

    NARCIS (Netherlands)

    Koopman, Daniëlle; Groot Koerkamp, Maureen; Jager, Pieter L.; Arkies, Hester; Knollema, Siert; Slump, Cornelis H.; Sanches, Pedro G.; van Dalen, Jorn A.

    2017-01-01

    Background: Our aim was to evaluate if a recently introduced TOF PET system with digital photon counting technology (Philips Healthcare), potentially providing an improved image quality over analogue systems, can fulfil EANM research Ltd (EARL) accreditation specifications for tumour imaging with

  17. 42 CFR 422.157 - Accreditation organizations.

    Science.gov (United States)

    2010-10-01

    ..., on an annual basis, summary data specified by CMS that relate to the past year's accreditation... respect to the standard or standards in question. (2) It complies with the application and reapplication... term of the approval, which may not exceed 6 years. (c) Ongoing responsibilities of an approved...

  18. The National Accreditation Board for Hospital and Health Care Providers accreditation programme in India.

    Science.gov (United States)

    Gyani, Girdhar J; Krishnamurthy, B

    2014-01-01

    Quality in health care is important as it is directly linked with patient safety. Quality as we know is driven either by regulation or by market demand. Regulation in most developing countries has not been effective, as there is shortage of health care providers and governments have to be flexible. In such circumstances, quality has taken a back seat. Accreditation symbolizes the framework for quality governance of a hospital and is based on optimum standards. Not only is India establishing numerous state of the art hospitals, but they are also experiencing an increase in demand for quality as well as medical tourism. India launched its own accreditation system in 2006, conforming to standards accredited by ISQua. This article shows the journey to accreditation in India and describes the problems encountered by hospitals as well as the benefits it has generated for the industry and patients.

  19. Utilization of radiation technique on the saccharification and fermentation of biomass

    Energy Technology Data Exchange (ETDEWEB)

    Kaetsu, I.; Kumakura, M.; Fujimura, T.; Yoshii, F.; Kojima, T.; Tamada, M. (Japan Atomic Energy Research Inst., Takasaki, Gunma. Takasaki Radiation Chemistry Research Establishment)

    1981-01-01

    The application of irradiation technique to the process of saccharification and subsequent fermentation of cellulosic wastes such as chaff and rice straw to obtain ethanol, was investigated. It was found that when waste raw materials were irradiated by ..gamma..-ray or electron beam, they became accessible to the subsequent enzymatic saccharification reaction. Irradiation of 10/sup 7/ to 10/sup 8/ Rad was enough for this effect. Some kind of additives reduced necessary dosage for this pretreatment. Cellulase, Trichoderma reesei which produce cellulase, and yeast were immobilized as biocatalysts for biomass conversion by radiation-induced polymerization of glass-forming monomer at low temperature. The immobilized cellulase showed almost the same activity of glucose production as the native cellulase. Continuous saccharification reaction was carried out by using the immobilized cellulase. The immobilized Trichoderma reesei and the immobilized yeast showed almost the same activity as the intact biocatalysts. It was concluded that the continuous saccharification and subsequent fermentation could be carried out effectively by using the immobilized biocatalysts. Spinach chloroplasts were immobilized by the same method as the first step for the conversion of water into hydrogen gas using solar energy. The immobilized chloroplasts kept the O/sub 2/ evolution activity in storage more than 30 days at 4/sup 0/C.

  20. Preparation of a newly microbial polymer using ionizing radiation technique and its conductivity

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Hwa Jung; Song, Aram; Kim, Dong Ho; Park, Hae Jun [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongup (Korea, Republic of)

    2016-11-15

    Extracellular polymeric substance (EPS) is produced by microorganisms for a variety of purpose in response to environmental stresses. The EPS are heterogeneous mixture composed dominantly of polysaccharides and proteins, with nucleic acid and lipid as minor constituents. Application of a bacterial EPS is in mostly bioremediation in environment and it applied to pharmaceutical industries including indwelling medical devices. Furthermore, the EPS studies have mostly been performed in the only level of bacterial culture system. In this study, we have first investigated the structural modification of EPS using ionizing radiation technique. The extracted EPS solution from bacterial culture step was exposed to gamma-irradiation at room temperature. Especially, the EPS was given irradiation at various ranges of 0, 2, 10 and 30 kGy from {sup 60}Co gamma-ray source. The structural property and surface morphology were characterized by using Fourier-transform infrared (FTIR) and field emission-scanning electron microscopy (FE-SEM). Also, the conductivity of EPS was determined by using the Van der PauW method, and the polymeric substances turned out to have semi-conductivity (about 5.38*10{sup -7})

  1. Utilization of radiation technique on the saccharification and fermentation of biomass

    International Nuclear Information System (INIS)

    Kaetsu, I.; Kumakura, M.; Fujimura, T.; Yoshii, F.; Kojima, T.; Tamada, M.

    1981-01-01

    The application of irradiation technique to the process of saccharification and subsequent fermentation of cellulosic wastes such as chaff and rice straw to obtain ethanol, was investigated. It was found that when waste raw materials were irradiated by γ-ray or electron beam, they became accessible to the subsequent enzymatic saccharification reaction. Irradiation of 10 7 to 10 8 Rad was enough for this effect. Some kind of additives reduced necessary dosage for this pretreatment. Cellulase, Trichoderma reesei which produce cellulase, and yeast were immobilized as biocatalysts for biomass conversion by radiation-induced polymerization of glass-forming monomer at low temperature. The immobilized cellulase showed almost the same activity of glucose production as the native cellulase. Continuous saccharification reaction was carried out by using the immobilized cellulase. The immobilized Trichoderma reesei and the immobilized yeast showed almost the same activity as the intact biocatalysts. It was concluded that the continuous saccharification and subsequent fermentation could be carried out effectively by using the immobilized biocatalysts. Spinach chloroplasts were immobilized by the same method as the first step for the conversion of water into hydrogen gas using solar energy. The immobilized chloroplasts kept the O 2 evolution activity in storage more than 30 days at 4 0 C. (author)

  2. Development of Styrene-Grafted Polyurethane by Radiation-Based Techniques

    Directory of Open Access Journals (Sweden)

    Jin-Oh Jeong

    2016-06-01

    Full Text Available Polyurethane (PU is the fifth most common polymer in the general consumer market, following Polypropylene (PP, Polyethylene (PE, Polyvinyl chloride (PVC, and Polystyrene (PS, and the most common polymer for thermosetting resins. In particular, polyurethane has excellent hardness and heat resistance, is a widely used material for electronic products and automotive parts, and can be used to create products of various physical properties, including rigid and flexible foams, films, and fibers. However, the use of polar polymer polyurethane as an impact modifier of non-polar polymers is limited due to poor combustion resistance and impact resistance. In this study, we used gamma irradiation at 25 and 50 kGy to introduce the styrene of hydrophobic monomer on the polyurethane as an impact modifier of the non-polar polymer. To verify grafted styrene, we confirmed the phenyl group of styrene at 690 cm−1 by Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR and at 6.4–6.8 ppm by 1H-Nuclear Magnetic Resonance (1H-NMR. Scanning Electron Microscope (SEM, X-ray Photoelectron Spectroscopy (XPS, Thermogravimetric Analysis (TGA and contact angle analysis were also used to confirm styrene introduction. This study has confirmed the possibility of applying high-functional composite through radiation-based techniques.

  3. Comparative accuracy of different techniques in planning radiation therapy of breast cancer

    International Nuclear Information System (INIS)

    Bignardi, M.; Frata, P.; Barbera, F.; Moretti, R.

    1991-01-01

    The authors report the results of the analysis of several factors contributing to the accuracy of treatment planning in the radiation therapy of breast cancer. Different techniques (non-radiological vs CT-based) were used for the acquisition of patients' data; different methods (manual vs computerized) were employed for dose calculation. As for geometric parameters describing the external outline and target volume, mean differences were lower than 4%. Switching from a completely manual method to a CT-based one with computerized calculation, a 3.56% mean decrease in the value of reference isodose (p<0.01) was observed, togheter with a 3.87% mean increase in the estimated inhomogeneity (p<0.001). The non-CT-based outline of target volume exhibited geographic missing of inner portions of the target in 8/16 patients. Our results demonstarte that treatment planning procedures can be a significant source of clinically relevant inaccuracy, which may affect treatment outcome and tumor control

  4. COMPARISON OF THE PERIPHERAL DOSES FROM DIFFERENT IMRT TECHNIQUES FOR PEDIATRIC HEAD AND NECK RADIATION THERAPY.

    Science.gov (United States)

    Toyota, Masahiko; Saigo, Yasumasa; Higuchi, Kenta; Fujimura, Takuya; Koriyama, Chihaya; Yoshiura, Takashi; Akiba, Suminori

    2017-11-01

    Intensity-modulated radiation therapy (IMRT) can deliver high and homogeneous doses to the target area while limiting doses to organs at risk. We used a pediatric phantom to simulate the treatment of a head and neck tumor in a child. The peripheral doses were examined for three different IMRT techniques [dynamic multileaf collimator (DMLC), segmental multileaf collimator (SMLC) and volumetric modulated arc therapy (VMAT)]. Peripheral doses were evaluated taking thyroid, breast, ovary and testis as the points of interest. Doses were determined using a radio-photoluminescence glass dosemeter, and the COMPASS system was used for three-dimensional dose evaluation. VMAT achieved the lowest peripheral doses because it had the highest monitor unit efficiency. However, doses in the vicinity of the irradiated field, i.e. the thyroid, could be relatively high, depending on the VMAT collimator angle. DMLC and SMLC had a large area of relatively high peripheral doses in the breast region. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Comparison of techniques for morphologic evaluation of glycerol-preserved human skim subjected to gamma radiation

    International Nuclear Information System (INIS)

    Bringel, Fabiana de A.; Isaac, Cesar; Herson, Marisa R.; Freitas, Anderson Z. de; Martinho Junior, Antonio C.; Mathor, Monica B.

    2011-01-01

    Extensive skin lesions expose the body to damaging agents, which makes spontaneous regeneration difficult and, in many cases, leads patient to death. In such cases, if there are no donating areas for auto graft, allografts can be used. In this type of graft, tissue is processed in tissue banks, where it can be subjected to radiosterilization. According to in vitro studies, gamma radiation, in doses higher than 25 kGy, causes breakdown of collagen I fibrils in the skin preserved in glycerol at 85% and this change influences fibroblast migration and deposition of new collagen. In order to assess if the alterations observed in vitro, would compromise in vivo use, transplants of human tissue, irradiated or not, were performed in Nude mice. After the surgery the skins of the mice was subjected to macroscopic analysis on the 3 rd , 7 th , 21 st and 90 th days; optical coherence tomography on the 90 th day and histological assay on the 3 rd , 7 th , 21 st days to compare the results of the repair process among the techniques, considering that the OCT allows in vivo and not destructive morphological analysis. According to the results obtained through OCT it was possible to observe a more organized repair process in the animals which received irradiated grafts (25 and 50 kGy) if compared to unirradiated grafts. It was not possible to observe such phenomena through macroscopic or histological evaluation. (author)

  6. Comparison of techniques for morphologic evaluation of glycerol-preserved human skim subjected to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bringel, Fabiana de A. [Faculty of Humanities, Economic and Health Sciences of Araguaina ITPAC (FAHESA/ITPAC/TO) Araguaina, TO (Brazil); Isaac, Cesar [Faculty of Medicine, University of Sao Paulo (FMUSP/SP) Sao Paulo, SP (Brazil); Herson, Marisa R., E-mail: marisah@vifm.org [Tissue Bank of Victoria, Victoria (Australia); Freitas, Anderson Z. de; Martinho Junior, Antonio C.; Mathor, Monica B., E-mail: azanardi@ipen.br, E-mail: mathor@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Radiation Technology Centre; Oliveira, Sergio F. de [Institute of Biomedical Sciences, University of Sao Paulo (ICB-USP/SP), SP (Brazil)

    2011-07-01

    Extensive skin lesions expose the body to damaging agents, which makes spontaneous regeneration difficult and, in many cases, leads patient to death. In such cases, if there are no donating areas for auto graft, allografts can be used. In this type of graft, tissue is processed in tissue banks, where it can be subjected to radiosterilization. According to in vitro studies, gamma radiation, in doses higher than 25 kGy, causes breakdown of collagen I fibrils in the skin preserved in glycerol at 85% and this change influences fibroblast migration and deposition of new collagen. In order to assess if the alterations observed in vitro, would compromise in vivo use, transplants of human tissue, irradiated or not, were performed in Nude mice. After the surgery the skins of the mice was subjected to macroscopic analysis on the 3{sup rd}, 7{sup th}, 21{sup st} and 90{sup th} days; optical coherence tomography on the 90{sup th} day and histological assay on the 3{sup rd}, 7{sup th}, 21{sup st} days to compare the results of the repair process among the techniques, considering that the OCT allows in vivo and not destructive morphological analysis. According to the results obtained through OCT it was possible to observe a more organized repair process in the animals which received irradiated grafts (25 and 50 kGy) if compared to unirradiated grafts. It was not possible to observe such phenomena through macroscopic or histological evaluation. (author)

  7. Utilization of radiation technique on the saccharification and fermentation of biomass

    Science.gov (United States)

    Kaetsu, I.; Kumakura, M.; Fujimura, T.; Yoshii, F.; Kojima, T.; Tamada, M.

    The application of irradiation technique to the process of saccharification and subsequent fermentation of cellulosic wastes such as chaff and rice straw to obtain ethanol, was investigated. It was found that when waste raw materials were irradiated by ?-ray or electron beam, they became accessible to the subsequent enzymatic saccharification reaction. Irradiation of 10 7-10 8 Rad was enough for this effect. Some kind of additives reduced necessary dosage for this pretreatment. Cellulase, Trichoderma reesei which produce cellulase, and yeast were immobilized as biocatalysts for biomass conversion by radiation-induced polymerization of glass-forming monomer at low temperature. The immobilized cellulase showed almost same activity of glucose production as the native cellulase. Continuous saccharification reaction was carried out by using the immobilized cellulase. The immobilized Trichoderma reesei and the immobilized yeast showed almost same activity as the intact biocatalysts. It was concluded that the continuous saccharification and subsequent fermentation could be carried out effectively by using the immobilized biocatalysts. Spinach chloroplasts were immobilized by the same method as the first step for the conversion of water into hydrogen gas using solar energy. The immobilized chloroplasts kept the O 2 evolution activity in storage more than 30 days at 4°C. Thermostatility of chloroplasts was also improved greatly by the immobilization.

  8. Digital pulse processing techniques for high resolution amplitude measurement of radiation detector

    International Nuclear Information System (INIS)

    Singhai, P.; Roy, A.; Dhara, P.; Chatterjee, S.

    2012-01-01

    The digital pulse processing techniques for high resolution amplitude measurement of radiation detector pulse is an effective replacement of expensive and bulky analog processing as the digital domain offers higher channel density and at the same time it is cheaper. We have demonstrated a prototype digital setup with highspeed sampling ADC with sampling frequency of 80-125 MHz followed by series of IIR filters for pulse shaping in a trigger-less acquisition mode. The IIR filters, peak detection algorithm and the data write-out logic was written on VHDL and implemented on FPGA. We used CAMAC as the read out platform. In conjunction with the full hardware implementation we also used a mixed platform with VME digitizer card with raw-sample read out using C code. The rationale behind this mixed platform is to test out various filter algorithms quickly on C and also to benchmark the performance of the chip level ADCs against the standard commercial digitizer in terms of noise or resolution. The paper describes implementation of both the methods with performance obtained in both the methods. (author)

  9. Evaluation of radiation-induced sensitization using electrochemical potentiokinetic reactivation technique for austenitic stainless steels

    International Nuclear Information System (INIS)

    Inazumi, T.; Bell, G.E.C.; Hishinuma, A.

    1990-01-01

    The electrochemical potentiokinetic reactivation (EPR) test technique was applied to the determination of sensitization in a neutron-irradiated (420 degree C, 10 dpa) titanium-modified austenitic stainless steel. Miniaturized specimens (3 mm diam by 0.25 mm thick) in solution-annealed and 25% cold-worked conditions were tested. The degree of sensitization (DOS) was calculated in terms of the reactivation charge (Pa). Results indicated the occurrence of radiation-induced sensitization when compared to control specimens thermally aged at the irradiation temperature. Post-EPR examination of the specimen surfaces showed etching across the face of each grain as well as at grain boundaries. This indicates that the Pa value normalized by the total grain boundary area, which is an accepted EPR-DOS criterion, cannot be directly used as an indicator of the DOS to determine the susceptibility of this irradiated material to intergranular stress corrosion cracking (IGSCC). Further investigations are necessary to correlate the results in this study to the IGSCC susceptibility of the irradiated stainless steel. 26 refs., 7 figs., 3 tabs

  10. Dental CT: examination technique, radiation load and anatomy; Dental-CT: Untersuchungstechnik, Strahlenbelastung und Anatomie

    Energy Technology Data Exchange (ETDEWEB)

    Lenglinger, F.X.; Muhr, T. [AKH Wels (Austria). Inst. fuer Radiologie; Krennmair, G. [Praxis fuer Zahn-, Mund- und Kieferheilkunde und Implantologie, Marchtrenk (Austria)

    1999-12-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [German] Die Einfuehrung im Bereich der Computertomographiesoftware (Dental-CT) ermoeglicht dem Radiologen zusaetzlich zu den ueblichen, von den Zahnaerzten durchgefuehrten Roentgenuntersuchungen eine ueberlagerungs- und verzerrungsfreie Darstellung des Ober- und Unterkiefers. In der Implantologie ist mit dieser Darstellung eine exakte Planung moeglich. Weiterhin haben sich Duennschicht-CT-Untersuchungen auch bei der Abklaerung von Zysten, Tumoren, Frakturen, tiefen Parodontitiden und retinierten Zaehnen bewaehrt. In dieser Zeit wird ein Ueberblick ueber die Anatomie, die Untersuchungstechnik des Dental-CT und die auftretende Strahlenbelastung gegeben. Basierend auf rezente Literaturangaben kann eine Reduktion der absorbierten Dosis bei gleichbleibender Bildqualitaet durch einfache Protokollmodifikationen erzielt werden. (orig.)

  11. Trends in Accreditation Council for Graduate Medical Education Accreditation for Subspecialty Fellowship Training in Plastic Surgery.

    Science.gov (United States)

    Silvestre, Jason; Serletti, Joseph M; Chang, Benjamin

    2018-05-01

    The purposes of this study were to (1) determine the proportion of plastic surgery residents pursuing subspecialty training relative to other surgical specialties, and (2) analyze trends in Accreditation Council for Graduate Medical Education accreditation of plastic surgery subspecialty fellowship programs. The American Medical Association provided data on career intentions of surgical chief residents graduating from 2014 to 2016. The percentage of residents pursuing fellowship training was compared by specialty. Trends in the proportion of accredited fellowship programs in craniofacial surgery, hand surgery, and microsurgery were analyzed. The percentage of accredited programs was compared between subspecialties with added-certification options (hand surgery) and subspecialties without added-certification options (craniofacial surgery and microsurgery). Most integrated and independent plastic surgery residents pursued fellowship training (61.8 percent versus 49.6 percent; p = 0.014). Differences existed by specialty from a high in orthopedic surgery (90.8 percent) to a low in colon and rectal surgery (3.2 percent). From 2005 to 2015, the percentage of accredited craniofacial fellowship programs increased, but was not significant (from 27.8 percent to 33.3 percent; p = 0.386). For hand surgery, the proportion of accredited programs that were plastic surgery (p = 0.755) and orthopedic surgery (p = 0.253) was stable, whereas general surgery decreased (p = 0.010). Subspecialty areas with added-certification options had more accredited fellowships than those without (100 percent versus 19.2 percent; p < 0.001). There has been slow adoption of accreditation among plastic surgery subspecialty fellowships, but added-certification options appear to be highly correlated.

  12. [Self-audit and tutor accreditation].

    Science.gov (United States)

    Ezquerra Lezcano, Matilde; Tamayo Ojeda, Carmen; Calvet Junoy, Silvia; Avellana Revuelta, Esteve; Vila-Coll, María Antonia; Morera Jordán, Concepción

    2010-02-01

    To describe the experience of using self-audit (SA) as a means of accrediting family and community medicine tutors, to analyse the knowledge that the tutors have on this self-assessment methodology, and to record their opinions on this method. Retrospective descriptive study and analysis of an opinion questionnaire. Family and community medicine teaching units (TU) in Catalonia. Tutors from family and community medicine TU in Catalonia (July 2001-July 2008). Training of the tutors in SA methodology, creation of a reference group and a correction cycle. Correction by peers of the SAs performed by the tutors according to previously determined criteria and subsequent issue of a report-feedback. Self-administered questionnaire by a group of TU tutors. A total of 673 SA were performed. The most frequent topic selected was diabetes mellitus in 27.9% of cases. The overall evaluation of the SA from a methodological point of view was correct in 44.5% of cases, improvable in 45.3%, and deficient in 10.2%. A total of 300 opinion questionnaires were issued. The response rate was 151/300 (50.03%). On the question about the usefulness of the SA in professional practice, 12% considered it very useful, 56% adequate, and 32% of little use or not useful. As regards whether it was a good means for the re-accreditation or accreditation of tutors, 66% considered that it was not. A high percentage of the SAs analysed are not carried out correctly, which indicates that tutors do not know this self-assessment method very well. They consider that SAs are a useful tool for improving clinical practice, but not a good means for accreditation and re-accreditation.

  13. Actual survey of dose evaluation method for standardization of radiation therapy techniques. With special reference to display method of radiation doses

    International Nuclear Information System (INIS)

    Kumagai, Kozo; Yoshiura, Takao; Izumi, Takashi; Araki, Fujio; Takada, Takuo; Jingu, Kenichi.

    1994-01-01

    This report presents the results of questionnaire survey for actual conditions of radiation therapy, which was conducted with the aim of establishing the standardization of radiation therapy techniques. Questionnaires were sent to 100 facilities in Japan, and 86 of these answered, consisting of 62 university hospitals, 2 national hospitals, 14 cancer centers, 4 prefectural or municipal hospitals, and 4 other hospitals. In addition to electron beam therapy, the following typical diseases for radiation therapy were selected as standard irradiation models: cancers of the larynx, esophagus, breast, and uterine cervix, and malignant lymphomas. According to these models, questionnaire results are analyzed in terms of the following four items: (1) irradiation procedures, (2) energy used for radiotherapy, (3) the depth for calculating target absorption doses, and (4) points for displaying target absorption doses. (N.K.)

  14. 22 CFR 96.99 - Converting an application for temporary accreditation to an application for full accreditation.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Converting an application for temporary accreditation to an application for full accreditation. 96.99 Section 96.99 Foreign Relations DEPARTMENT OF... INTERCOUNTRY ADOPTION ACT OF 2000 (IAA) Procedures and Standards Relating to Temporary Accreditation § 96.99...

  15. Role and Evaluation of Interlaboratory Comparison Results in Laboratory Accreditation

    Science.gov (United States)

    Bode, P.

    2008-08-01

    Participation in interlaboratory comparisons provides laboratories an opportunity for independent assessment of their analytical performance, both in absolute way and in comparison with those by other techniques. However, such comparisons are hindered by differences in the way laboratories participate, e.g. at best measurement capability or under routine conditions. Neutron activation analysis laboratories, determining total mass fractions, often see themselves classified as `outliers' since the majority of other participants employ techniques with incomplete digestion methods. These considerations are discussed in relation to the way results from interlaboratory comparisons are evaluated by accreditation bodies following the requirements of Clause 5.9.1 of the ISO/IEC 17025:2005. The discussion and conclusions come largely forth from experiences in the author's own laboratory.

  16. Does accreditation stimulate change? A study of the impact of the accreditation process on Canadian healthcare organizations

    Directory of Open Access Journals (Sweden)

    Shabah Abdo

    2010-04-01

    Full Text Available Abstract Background One way to improve quality and safety in healthcare organizations (HCOs is through accreditation. Accreditation is a rigorous external evaluation process that comprises self-assessment against a given set of standards, an on-site survey followed by a report with or without recommendations, and the award or refusal of accreditation status. This study evaluates how the accreditation process helps introduce organizational changes that enhance the quality and safety of care. Methods We used an embedded multiple case study design to explore organizational characteristics and identify changes linked to the accreditation process. We employed a theoretical framework to analyze various elements and for each case, we interviewed top managers, conducted focus groups with staff directly involved in the accreditation process, and analyzed self-assessment reports, accreditation reports and other case-related documents. Results The context in which accreditation took place, including the organizational context, influenced the type of change dynamics that occurred in HCOs. Furthermore, while accreditation itself was not necessarily the element that initiated change, the accreditation process was a highly effective tool for (i accelerating integration and stimulating a spirit of cooperation in newly merged HCOs; (ii helping to introduce continuous quality improvement programs to newly accredited or not-yet-accredited organizations; (iii creating new leadership for quality improvement initiatives; (iv increasing social capital by giving staff the opportunity to develop relationships; and (v fostering links between HCOs and other stakeholders. The study also found that HCOs' motivation to introduce accreditation-related changes dwindled over time. Conclusions We conclude that the accreditation process is an effective leitmotiv for the introduction of change but is nonetheless subject to a learning cycle and a learning curve. Institutions invest

  17. History, organization, and oversight of the accredited dosimetry calibration laboratories by the AAPM

    International Nuclear Information System (INIS)

    Rozenfeld, M.

    1993-01-01

    For more than 20 years, the American Association of Physicists in Medicine (AAPM) has operated an accreditation program for secondary standards laboratories that calibrate radiation measuring instruments. Except for one short period, that program has been able to provide the facilities to satisfy the national need for accurate calibrations of such instruments. That exception, in 1981, due to the combination of the U.S. Nuclear Regulatory Commission (NRC) requiring instrument calibrations by users of cobalt-60 teletherapy units and the withdrawal of one of the three laboratories accredited at that time. However, after successful operation as a Task Group of the Radiation Therapy Committee (RTC) of the AAPM for two decades, a reorganization of this structure is now under serious consideration by the administration of the AAPM

  18. History, organization, and oversight of the accredited dosimetry calibration laboratories by the AAPM

    Energy Technology Data Exchange (ETDEWEB)

    Rozenfeld, M. [St. James Hospital and Health Centers, Chicago Heights, IL (United States)

    1993-12-31

    For more than 20 years, the American Association of Physicists in Medicine (AAPM) has operated an accreditation program for secondary standards laboratories that calibrate radiation measuring instruments. Except for one short period, that program has been able to provide the facilities to satisfy the national need for accurate calibrations of such instruments. That exception, in 1981, due to the combination of the U.S. Nuclear Regulatory Commission (NRC) requiring instrument calibrations by users of cobalt-60 teletherapy units and the withdrawal of one of the three laboratories accredited at that time. However, after successful operation as a Task Group of the Radiation Therapy Committee (RTC) of the AAPM for two decades, a reorganization of this structure is now under serious consideration by the administration of the AAPM.

  19. Application of the planar-scanning technique to the near-field dosimetry of millimeter-wave radiators.

    Science.gov (United States)

    Zhao, Jianxun; Lu, Hongmin; Deng, Jun

    2015-02-01

    The planar-scanning technique was applied to the experimental measurement of the electric field and power flux density (PFD) in the exposure area close to the millimeter-wave (MMW) radiator. In the near-field region, the field and PFD were calculated from the plane-wave spectrum of the field sampled on a scan plane far from the radiator. The measurement resolution was improved by reducing the spatial interval between the field samples to a fraction of half the wavelength and implementing multiple iterations of the fast Fourier transform. With the reference to the results from the numerical calculation, an experimental evaluation of the planar-scanning measurement was made for a 50 GHz radiator. Placing the probe 1 to 3 wavelengths from the aperture of the radiator, the direct measurement gave the near-field data with significant differences from the numerical results. The planar-scanning measurement placed the probe 9 wavelengths away from the aperture and effectively reduced the maximum and averaged differences in the near-field data by 70.6% and 65.5%, respectively. Applied to the dosimetry of an open-ended waveguide and a choke ring antenna for 60 GHz exposure, the technique proved useful to the measurement of the PFD in the near-field exposure area of MMW radiators. © 2015 Wiley Periodicals, Inc.

  20. [Accreditation of clinical laboratories based on ISO standards].

    Science.gov (United States)

    Kawai, Tadashi

    2004-11-01

    International Organization for Standardization (ISO) have published two international standards (IS) to be used for accreditation of clinical laboratories; ISO/IEC 17025:1999 and ISO 15189:2003. Any laboratory accreditation body must satisfy the requirements stated in ISO/IEC Guide 58. In order to maintain the quality of the laboratory accreditation bodies worldwide, the International Laboratory Accreditation Cooperation (ILAC) has established the mutual recognition arrangement (MRA). In Japan, the International Accreditation Japan (IAJapan) and the Japan Accreditation Board for Conformity Assessment (JAB) are the members of the ILAC/MRA group. In 2003, the Japanese Committee for Clinical Laboratory Standards (JCCLS) and the JAB have established the Development Committee of Clinical Laboratory Accreditation Program (CLAP), in order to establish the CLAP, probably starting in 2005.

  1. Accreditation in a public hospital: perceptions of a multidisciplinary team.

    Science.gov (United States)

    Camillo, Nadia Raquel Suzini; Oliveira, João Lucas Campos de; Bellucci Junior, José Aparecido; Cervilheri, Andressa Hirata; Haddad, Maria do Carmo Fernandez Lourenço; Matsuda, Laura Misue

    2016-06-01

    to analyze the perceptions of the multidisciplinary team on Accreditation in a public hospital. descriptive, exploratory, qualitative research, performed in May 2014, using recorded individual interviews. In total, 28 employees of a public hospital, Accredited with Excellence, answered the guiding question: "Tell me about the Accreditation system used in this hospital". The interviews were transcribed and subjected to content analysis. of the speeches, three categories emerged: Advantages offered by the Accreditation; Accredited public hospital resembling a private hospital; Pride/satisfaction for acting in an accredited public hospital. participants perceived Accreditation as a favorable system for a quality management in the public service because it promotes the development of professional skills and improves cost management, organizational structure, management of assistance and perception of job pride/satisfaction.

  2. Radiation therapy for malignant gliomas in adults. Analysis of treatment results regarding factors on the radiation technique

    International Nuclear Information System (INIS)

    Tanaka, Yoshiaki; Kawamori, Jiro; Saito, Tsutomu; Karasawa, Katsuyuki; Shitara, Nobuyuki; Matsutani, Masao.

    1997-01-01

    During 19 years, 309 patients with astrocytic tumors (173 of glioblastoma multiforme (GBM), 41 of anaplastic astrocytoma (AA), and 95 of astrocytoma) were treated with radiation therapy. Initially a dose of 50 Gy was given with an extended field, then the target volume was decreased to the contrast enhancing lesion plus 1-2 cm margin and treated to the total dose ranging from 60 Gy to 66 Gy for GBM and about 60 Gy for AA. Fifty-four patients underwent surgical resection combined with a single dose of 15-20 Gy by intraoperative radiation therapy (IORT). The one-, 2-, and 3-year survival rates and the median survival time (MST) of patients with GBM were 56%, 27%, 16%, and 495 days, respectively. For patients with AA, these were 63%, 50%, 33%, and 762 days, respectively. From analysis on GBM, patients treated with IORT were survived longer than without IORT, significantly (p 2 , were significantly inferior than with less portal size (p<0.05). Patients treated with conformation radiotherapy (CFRT) were superior on survival rates than without it on GBM, however, there was no difference on AA. The treatment factors for radiation therapy which affected for prolonging survival time were considered as dose, size of irradiated portals, application of IORT and CFRT, especially on patients with GBM. (author)

  3. Circuit and Measurement Technique for Radiation Induced Drift in Precision Capacitance Matching

    Science.gov (United States)

    Prasad, Sudheer; Shankar, Krishnamurthy Ganapathy

    2013-04-01

    In the design of radiation tolerant precision ADCs targeted for space market, a matched capacitor array is crucial. The drift of capacitance ratios due to radiation should be small enough not to cause linearity errors. Conventional methods for measuring capacitor matching may not achieve the desired level of accuracy due to radiation induced gain errors in the measurement circuits. In this work, we present a circuit and method for measuring capacitance ratio drift to a very high accuracy (<; 1 ppm) unaffected by radiation levels up to 150 krad.

  4. Vehicle tracking based technique for radiation monitoring during nuclear or radiological emergency

    International Nuclear Information System (INIS)

    Saindane, Shashank S.; Otari, Anil D.; Suri, M.M.K.; Patil, S.S.; Pradeepkumar, K.S.; Sharma, D.N.

    2010-01-01

    Radiation Safety Systems Division, BARC has developed an advanced online radiation measurement cum vehicle tracking system for use. For the preparedness for response to any nuclear/radiological emergency scenario which may occur anywhere, the system designed is a Global System for Mobile (GSM) based Radiation Monitoring System (GRaMS) along with a Global Positioning System (GPS). It uses an energy compensated GM detector for radiation monitoring and is attached with commercially available Global Positioning System (GPS) for online acquisition of positional coordinates with time, and GSM modem for online data transfer to a remote control centre. The equipment can be operated continuously while the vehicle is moving

  5. Adjuvant radiation of the axilla for skin cancer - evolution of a technique

    International Nuclear Information System (INIS)

    Fogarty, G.; Smith, A.; Ainslie, J.

    2003-01-01

    Phase II and retrospective data show that adjuvant radiotherapy to the axilla improves local control in skin cancers such as melanoma, squamous cell carcinoma and Merkel cell carcinoma. Optimisation of the volume treated, dose and fractionation patterns are essential in order to avoid long term toxicities to nearby dose sensitive structures in survivors. Traditionally this has been planned with plain film simulation and a certain percentage of treatment toxicity has been accepted as inevitable to deliver appropriate treatment. The recent advent of CT planning has enabled a better understanding of the origin of toxicity based on the amount of normal structures actually in the treated volume. Other variables such as the differences in individual patient anatomy and the differences between the prescribing radiation oncologists' understanding of the anatomy of the axilla and volumes, such as clinical target volume and planning target volume, have also been discovered when compared with plain film simulation. Case studies are presented which suggest causes of toxicity and techniques of optimization based on CT planning which differ with other variables such as patient anatomy and dose-volume histograms of relevant structures.. Baseline parameters that outline a standard treatment plan based on CT planning are offered that should assist in minimising toxicity and maximising the treatment efficacy. This could also be offered as a template so that inter-doctor and inter-centre variations are kept to a minimum. The latter is important in ensuring there is standardisation of treatment particularly when it is imperative to maintain consistency of treatment volumes in multi-centre clinical trials

  6. Reduction in radiation dose with reconstruction technique in the brain perfusion CT

    Science.gov (United States)

    Kim, H. J.; Lee, H. K.; Song, H.; Ju, M. S.; Dong, K. R.; Chung, W. K.; Cho, M. S.; Cho, J. H.

    2011-12-01

    The principal objective of this study was to verify the utility of the reconstruction imaging technique in the brain perfusion computed tomography (PCT) scan by assessing reductions in the radiation dose and analyzing the generated images. The setting used for image acquisition had a detector coverage of 40 mm, a helical thickness of 0.625 mm, a helical shuttle mode scan type and a rotation time of 0.5 s as the image parameters used for the brain PCT scan. Additionally, a phantom experiment and an animal experiment were carried out. In the phantom and animal experiments, noise was measured in the scanning with the tube voltage fixed at 80 kVp (kilovolt peak) and the level of the adaptive statistical iterative reconstruction (ASIR) was changed from 0% to 100% at 10% intervals. The standard deviation of the CT coefficient was measured three times to calculate the mean value. In the phantom and animal experiments, the absorbed dose was measured 10 times under the same conditions as the ones for noise measurement before the mean value was calculated. In the animal experiment, pencil-type and CT-dedicated ionization chambers were inserted into the central portion of pig heads for measurement. In the phantom study, as the level of the ASIR changed from 0% to 100% under identical scanning conditions, the noise value and dose were proportionally reduced. In our animal experiment, the noise value was lowest when the ASIR level was 50%, unlike in the phantom study. The dose was reduced as in the phantom study.

  7. Evaluation of surface contamination based on certifiably traceable, internationally accreditable measurements

    International Nuclear Information System (INIS)

    Whitlock, G.D.

    1992-01-01

    National Accreditation and Measurement Service (NAMAS) adopted by the EUROMET agreement requires that the calibration of monitoring instruments be traceable internationally with the objective that radiation hazard assessment be improved. This objective is achieved for Tritium surface contamination by employing calibration sources and evaluation methods which comply with ISO standards including the measurement of activity removable by Volatilization as well as dust. Consideration should be given to organic binding of tritium in the skin with its implications in the event of litigation. (author)

  8. Assessment of dose to the expected overexposed radiation workers in Malaysia using dicentric technique from 2005 - 2006

    International Nuclear Information System (INIS)

    Noraisyah Mohd Yusof; Mohd Rodzi Ali; Noriah Jamal; Rehir Dahalan

    2008-08-01

    Malaysian Nuclear Agency is recognized by the Atomic Energy Licensing Board (AELB) as a National Biodosimetry Laboratory for performing the chromosome aberration tests in Malaysia. The test is to be done for radiation workers who received doses of more than the annual dose limit of 50 mSv or losses of film badge. This paper aims at presenting results of assessment of dose to the expected overexposed radiation workers in Malaysia using dicentric technique from year 2005 to 2006. Between that period of time, 20 blood samples (loss of film badge: 5 samples, overexposed: 13 samples and follow-up cases: 2 samples) were received from the AELB and the assessment of chromosome aberration were performed. The information on whole body exposure (WBE) was also received together with the samples for overexposed worker. We used the gold standard technique, which is the dicentric assay to analyze the blood samples. The technique is described in the IAEA Technical Report Series No. 405. The results were then analyzed and compared with the respective WBE for the overexposed worker. We found that no doses were observed for workers who loss their film badges and for follow-up cases. 30.8% of the overexposed workers show doses of more than 50 mSv. However, 69.2% shows doses lower than the annual limit. Variation of results may be due to delayed blood sampling from the workers. This technique is especially useful for immediate assessment of radiation exposure. (Author)

  9. Risk of whole body radiation exposure and protective measures in fluoroscopically guided interventional techniques: a prospective evaluation

    Directory of Open Access Journals (Sweden)

    Rivera Jose

    2003-08-01

    Full Text Available Abstract Background Fluoroscopic guidance is frequently utilized in interventional pain management. The major purpose of fluoroscopy is correct needle placement to ensure target specificity and accurate delivery of the injectate. Radiation exposure may be associated with risks to physician, patient and personnel. While there have been many studies evaluating the risk of radiation exposure and techniques to reduce this risk in the upper part of the body, the literature is scant in evaluating the risk of radiation exposure in the lower part of the body. Methods Radiation exposure risk to the physician was evaluated in 1156 patients undergoing interventional procedures under fluoroscopy by 3 physicians. Monitoring of scattered radiation exposure in the upper and lower body, inside and outside the lead apron was carried out. Results The average exposure per procedure was 12.0 ± 9.8 seconds, 9.0 ± 0.37 seconds, and 7.5 ± 1.27 seconds in Groups I, II, and III respectively. Scatter radiation exposure ranged from a low of 3.7 ± 0.29 seconds for caudal/interlaminar epidurals to 61.0 ± 9.0 seconds for discography. Inside the apron, over the thyroid collar on the neck, the scatter radiation exposure was 68 mREM in Group I consisting of 201 patients who had a total of 330 procedures with an average of 0.2060 mREM per procedure and 25 mREM in Group II consisting of 446 patients who had a total of 662 procedures with average of 0.0378 mREM per procedure. The scatter radiation exposure was 0 mREM in Group III consisting of 509 patients who had a total 827 procedures. Increased levels of exposures were observed in Groups I and II compared to Group III, and Group I compared to Group II. Groin exposure showed 0 mREM exposure in Groups I and II and 15 mREM in Group III. Scatter radiation exposure for groin outside the apron in Group I was 1260 mREM and per procedure was 3.8182 mREM. In Group II the scatter radiation exposure was 400 mREM and with 0.6042 m

  10. New technique for radiation detection by instruments based on microchannel plates

    International Nuclear Information System (INIS)

    Ammosov, V.V.; Bolozdynya, A.I.; Kubantsev, M.A.; Lebedenko, V.N.; Suvorov, A.L.

    1986-01-01

    Coordinate information can be obtained directly from microchanel plates (MCP) as storage matrix in MCP based radiation detectors, which is proved using as an example the registering of pulsed laser ultraviolet radiation. For read-out and representation of the information the TV channel was used: the vidicon electron-optical system - TV transmission camera - TV monitor

  11. ACEHSA accreditation safeguards the public interest.

    Science.gov (United States)

    Sundre, Steven M

    2004-01-01

    Daily, we are reminded that the public's investment in attaining quality health and medical care is among the most important priorities of our nation's citizens. Central to realizing that attainment is the level of professional competence of those charged with managing the nation's health resources. The not-for-profit Accrediting Commission on Education for Health Services Administration is the sole national organization governing the standards by which future health managers, administrators, and executives are educated and trained in accredited graduate programs. The impact of the ACEHSA is growing as health and medical leaders, government and regulatory policy-makers, insurance executives, special interest groups, and, of course, members of the public increasingly realize that top-flight healthcare delivery requires excellence in the management of health resources.

  12. Acid effects in the styrene comonomer technique for radiation grafting to wool

    International Nuclear Information System (INIS)

    Garnett, J.L.; Kenyon, R.S.

    1977-01-01

    Two processes are thought to contribute to the grafting of monomers to wool in the presence of acid under the influence of ionizing radiation. At temperatures of 45 0 C, acid alone will catalyze grafting to wool over a period of 18 hr and at much slower rates at room temperature. However, cellulose and polyolefins do not readily graft at these temperatures by acid-catalyzed process alone, radiation is also necessary. It is thought that in grafting to wool the radiation chemistry mechanisms and the mechanical swelling of acid both contribute appreciably to the radiation copolymerization; but with cellulose and the polyolefins, where acid-catalyzed grafting is approximately zero, the radiation process predominates

  13. Handling technique of spore-forming bacteria in radiation sterilization. 2. Determination of numbers and radiation resistance of spores

    International Nuclear Information System (INIS)

    Koshikawa, Tomihiko

    1994-01-01

    Stepwise ten-fold dilution of bacterial solution is required in the determination of bacterial spores. For this, the selection of diluted solution is important according to the purpose of experiment. First, the preparation of suspension of bacterial spores and selection of diluted solution are presented. Then, a method for determining the number of bacterial spores in materials is outlined in terms of dilution methods of bacterial solution (shaking and homogenization) and application method of diluted solution to the plating medium. Finally, a method for determining radiation resistance of spore-forming bacteria is explained according to the measurement conditions (suspension of bacterial spores and filters applied with bacterial spores). (N.K.)

  14. Handling technique of spore-forming bacteria in radiation sterilization. 2. Determination of numbers and radiation resistance of spores

    Energy Technology Data Exchange (ETDEWEB)

    Koshikawa, Tomihiko [Japan Radioisotope Association, Shiga (Japan). Koka Laboratory

    1994-12-01

    Stepwise ten-fold dilution of bacterial solution is required in the determination of bacterial spores. For this, the selection of diluted solution is important according to the purpose of experiment. First, the preparation of suspension of bacterial spores and selection of diluted solution are presented. Then, a method for determining the number of bacterial spores in materials is outlined in terms of dilution methods of bacterial solution (shaking and homogenization) and application method of diluted solution to the plating medium. Finally, a method for determining radiation resistance of spore-forming bacteria is explained according to the measurement conditions (suspension of bacterial spores and filters applied with bacterial spores). (N.K.).

  15. Detection of ionizing radiations by studying ceramic tiles materials using thermoluminescence technique

    Science.gov (United States)

    Mandavia, H. C.; Murthy, K. V. R.; Purohit, R. U.

    2017-05-01

    Natural background radiation comes from two primary sources: cosmic radiation and terrestrial sources. Our natural environment has both livings and non-livings like - Sun, Moon, Sky, Air, Water, Soil, Rivers, Mountains, Forests, besides plants and animals. The worldwide average background dose for a human being is about 2.4 millisievert (mSv) per year. This exposure is mostly from cosmic radiation and natural radionuclides in the environment. The Earth, and all living things on it, are constantly bombarded by radiation from outer space. This radiation primarily consists of positively charged ions from protons to iron and larger nuclei derived sources outside our solar system. This radiation interacts with atoms in the atmosphere to create secondary radiation, including X-rays, muons, protons, alpha particles, pions, electrons, and neutrons. The present study discusses the utility of ceramic tiles as radiation dosimeters in case of nuclear fallout. Many flooring materials most of them are in natural form are used to manufacture floor tiles for household flooring purpose. Many natural minerals are used as the raw materials required for the manufacturing ceramic ware. The following minerals are used to manufacturing the ceramic tiles i.e. Quartz, Feldspar, Zircon, Talc, Grog, Alumina oxide, etc. Most of the minerals are from Indian mines of Gujarat and Rajasthan states, some of are imported from Russian subcontinent. The present paper reports the thermoluminescence dosimetry Study of Feldspar and Quartz minerals collected from the ceramic tiles manufacturing unit, Morbi. The main basis in the Thermoluminescence Dosimetry (TLD) is that TL output is directly proportional to the radiation dose received by the phosphor and hence provides the means of estimating unknown radiations from environment.

  16. Automatic online adaptive radiation therapy techniques for targets with significant shape change: a feasibility study

    International Nuclear Information System (INIS)

    Court, Laurence E; Tishler, Roy B; Petit, Joshua; Cormack, Robert; Chin Lee

    2006-01-01

    This work looks at the feasibility of an online adaptive radiation therapy concept that would detect the daily position and shape of the patient, and would then correct the daily treatment to account for any changes compared with planning position. In particular, it looks at the possibility of developing algorithms to correct for large complicated shape change. For co-planar beams, the dose in an axial plane is approximately associated with the positions of a single multi-leaf collimator (MLC) pair. We start with a primary plan, and automatically generate several secondary plans with gantry angles offset by regular increments. MLC sequences for each plan are calculated keeping monitor units (MUs) and number of segments constant for a given beam (fluences are different). Bulk registration (3D) of planning and daily CT images gives global shifts. Slice-by-slice (2D) registration gives local shifts and rotations about the longitudinal axis for each axial slice. The daily MLC sequence is then created for each axial slice/MLC leaf pair combination, by taking the MLC positions from the pre-calculated plan with the nearest rotation, and shifting using a beam's-eye-view calculation to account for local linear shifts. A planning study was carried out using two head and neck region MR images of a healthy volunteer which were contoured to simulate a base-of-tongue treatment: one with the head straight (used to simulate the planning image) and the other with the head tilted to the left (the daily image). Head and neck treatment was chosen to evaluate this technique because of its challenging nature, with varying internal and external contours, and multiple degrees of freedom. Shape change was significant: on a slice-by-slice basis, local rotations in the daily image varied from 2 to 31 deg, and local shifts ranged from -0.2 to 0.5 cm and -0.4 to 0.0 cm in right-left and posterior-anterior directions, respectively. The adapted treatment gave reasonable target coverage (100%, 90

  17. The globalization of accreditation in the professions.

    Science.gov (United States)

    Lenn, M P

    1996-01-01

    The direct relationship between educational quality and a successful economy, the proliferation of regional and global trade agreements which encourage professional mobility, and the growing international recognition of academic degrees are contributing factors to the globalization of quality assurance in higher education, including accreditation. On every continent, attention is being paid to developing professional educational standards within an international context, assuring that ¿world class¿ professionals are produced for international as well as national practice.

  18. How Project Management Tools Aid in Association to Advance Collegiate Schools of Business (AACSB) International Maintenance of Accreditation

    Science.gov (United States)

    Cann, Cynthia W.; Brumagim, Alan L.

    2008-01-01

    The authors present the case of one business college's use of project management techniques as tools for accomplishing Association to Advance Collegiate Schools of Business (AACSB) International maintenance of accreditation. Using these techniques provides an efficient and effective method of organizing maintenance efforts. In addition, using…

  19. The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy

    International Nuclear Information System (INIS)

    Goo, Jang Hyeon; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Park, Jin Hong

    2014-01-01

    The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with TrueBeam TM STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy

  20. The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Jang Hyeon; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Park, Jin Hong [Dept. of Radiation Oncology, Seoul national university Bundang hospital, Sungnam (Korea, Republic of)

    2014-12-15

    The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with TrueBeam{sup TM} STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.

  1. Radiation protection dosimetry and calibrations

    International Nuclear Information System (INIS)

    Verhavere, Ph.

    2007-01-01

    At the SCK-CEN different specialised services are delivered for a whole range of external and internal customers in the radiation protection area. For the expertise group of radiation protection dosimetry and calibrations, these services are organized in four different laboratories: dosimetry, anthropogammametry, nuclear calibrations and non-nuclear calibrations. The services are given by a dedicated technical staff who has experience in the handling of routine and specialised cases. The scientific research that is performed by the expertise group makes sure that state-of-the-art techniques are being used, and that constant improvements and developments are implemented. Quality Assurance is an important aspect for the different services, and accreditation according national and international standards is achieved for all laboratories

  2. The study of chromosome aberration yield in human lymphocytes as an indicator of radiation dose. 1. Techniques

    International Nuclear Information System (INIS)

    Purrott, R.J.; Lloyd, D.C.

    1972-08-01

    Estimates of exposure to ionizing radiation can be obtained by determining the yield of chromosome aberrations in cultured human lymphocytes. Chromosomes can only be conveniently examined during cell division. The lymphocytes, which do not normally divide whilst circulating, are stimulated to divide during a 48-hour culture period. Two types of culture technique are described, one of which employs a lymphocyte-enriched inoculum and the other which uses whole blood. After culture the cells are harvested, dispensed onto slides and prepared for microscopic examination. An account is also given of the analysis of various types of radiation-induced chromosome aberrations and of the construction of calibration curves for certain types and rates of radiation which are used to interpret the aberration yields in terms of dose. (author)

  3. Study of the variation of radiation dose in function of the radiological techniques used in X-ray diagnosis exams

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Marco A.R., E-mail: marfernandes@fmb.unesp.br [Faculty of Medicine. UNESP, Botucatu (FMB), SP (Brazil); Reis, Charlene O.; Garcia, Paulo L. [Institute of Biosciences of Botucatu. UNESP, Botucatu, SP (Brazil); Nucleate Radiometry Ltd., Aracatuba, SP (Brazil); Lima, Marcelo A.F.; Dalaqua, Fernando L.D. [UNESP, Botucatu, SP (Brazil). Hospital. Radiology Service

    2011-07-01

    This paper values the importance of the implantation of a quality control program in medical x-ray diagnosis services that it seeks mainly to the reduction of the radiation dose applied in the radiology exams, and attempt to the precepts of the Effective Legislation as for the Basic Guidelines of Radiological Protection (law decree MS no. 453 in June 1{sup st} 1998). The study was accomplished Radiology Section of the Medicine Faculty - FMB (UNESP - Botucatu) and it consisted of the accomplishment of measures of the radiation dose applied in the radiological exams, taking as base the x-rays techniques realized by four technicians in radiology the service, using only one x-rays equipment. Was intended analyze the variation of the radiation dose in function of the different applied technical parameters, and this way, guide the professionals as for the possibility of obtaining of x-ray images of better quality and smaller patient exposition. For radiation dose measure a detector of solid state was utilized. During the accomplishment of the measures it was verified that there no a general consensus among the technicians of the section being observed differences of the order of 80% in the mAs. In terms of radiation dose measured, the largest value of verified was 4.752 mGy (exam of lateral lumbar column) and the smallest value of 0.165 mGy (child's thorax).The results showed that a standardization in the x-ray techniques executed by the professionals of the section will be able to reduce significantly the radiation exposition of the assisted patients. (author)

  4. Study of the variation of radiation dose in function of the radiological techniques used in X-ray diagnosis exams

    International Nuclear Information System (INIS)

    Fernandes, Marco A.R.; Reis, Charlene O.; Garcia, Paulo L.; Lima, Marcelo A.F.; Dalaqua, Fernando L.D.

    2011-01-01

    This paper values the importance of the implantation of a quality control program in medical x-ray diagnosis services that it seeks mainly to the reduction of the radiation dose applied in the radiology exams, and attempt to the precepts of the Effective Legislation as for the Basic Guidelines of Radiological Protection (law decree MS no. 453 in June 1 st 1998). The study was accomplished Radiology Section of the Medicine Faculty - FMB (UNESP - Botucatu) and it consisted of the accomplishment of measures of the radiation dose applied in the radiological exams, taking as base the x-rays techniques realized by four technicians in radiology the service, using only one x-rays equipment. Was intended analyze the variation of the radiation dose in function of the different applied technical parameters, and this way, guide the professionals as for the possibility of obtaining of x-ray images of better quality and smaller patient exposition. For radiation dose measure a detector of solid state was utilized. During the accomplishment of the measures it was verified that there no a general consensus among the technicians of the section being observed differences of the order of 80% in the mAs. In terms of radiation dose measured, the largest value of verified was 4.752 mGy (exam of lateral lumbar column) and the smallest value of 0.165 mGy (child's thorax).The results showed that a standardization in the x-ray techniques executed by the professionals of the section will be able to reduce significantly the radiation exposition of the assisted patients. (author)

  5. Simultaneous demonstration of UV-type and ionizing radiation-type DNA repair by the nucleoid sedimentation technique

    International Nuclear Information System (INIS)

    Aldenhoff, P.; Sperling, K.

    1984-01-01

    The nucleoid sedimentation technique is one of the most sensitive methods for measuring DNA excision repair. With this technique, it is shown that both UV- and ionizing radiation-type repair (the latter induced by bleomycin) can be discriminated in HeLa and normal diploid cells using 1-β-D-arabinofuranosylcytosine. The latter compound inhibits UV-type repair synthesis, and thus causes DNA breaks due to enzymic incision to persist, but has no effect on rejoining DNA after ionizing radiation-type damage. It was then possible to prove that 4-nitroquinoline-1-oxide induces both types of lesions which are repaired simultaneously. This effect could be demonstrated in HeLa and normal human diploid cells in a single experimental set-up. (Auth.)

  6. Modeling techniques for predicting long-term consequences of the effects of radiation on natural aquatic populations and ecosystems

    International Nuclear Information System (INIS)

    Van Winkle, W.

    1977-01-01

    Appropriate modeling techniques already exist for investigating some long-term consequences of the effects of radiation on natural aquatic populations and ecosystems, even if to date these techniques have not been used for this purpose. At the low levels of irradiation estimated to occur in natural aquatic systems, effects are difficult to detect at even the individual level much less the population or ecosystem level where the subtle effects of radiation are likely to be completely overshadowed by the effects of other environmental factors and stresses and the natural variability of the system. The claim that population and ecosystem models can be accurate and reliable predictive tools in assessing any stress has been oversold. Nonetheless, the use of these tools can be useful for learning more about the effects of radioactive releases on aquatic populations and ecosystems

  7. Scoping medical tourism and international hospital accreditation growth.

    Science.gov (United States)

    Woodhead, Anthony

    2013-01-01

    Uwe Reinhardt stated that medical tourism can do to the US healthcare system what the Japanese automotive industry did to American carmakers after Japanese products developed a value for money and reliability reputation. Unlike cars, however, healthcare can seldom be test-driven. Quality is difficult to assess after an intervention (posteriori), therefore, it is frequently evaluated via accreditation before an intervention (a priori). This article aims to scope the growth in international accreditation and its relationship to medical tourism markets. Using self-reported data from Accreditation Canada, Joint Commission International (JCI) and Australian Council on Healthcare Standards (ACHS), this article examines how quickly international accreditation is increasing, where it is occurring and what providers have been accredited. Since January 2000, over 350 international hospitals have been accredited; the JCI's total nearly tripling between 2007-2011. Joint Commission International staff have conducted most international accreditation (over 90 per cent). Analysing which countries and regions where the most international accreditation has occurred indicates where the most active medical tourism markets are. However, providers will not solely be providing care for medical tourists. Accreditation will not mean that mistakes will never happen, but that accredited providers are more willing to learn from them, to varying degrees. If a provider has been accredited by a large international accreditor then patients should gain some reassurance that the care they receive is likely to be a good standard. The author questions whether commercializing international accreditation will improve quality, arguing that research is necessary to assess the accreditation of these growing markets.

  8. State-of-the-art cytogenetic techniques to detect radiation damage induced by low doses bin human lymphocytes

    International Nuclear Information System (INIS)

    Hadjidekova, V.

    2004-01-01

    Cytogenetic techniques are the most sensitive and reliable tools for bio-monitoring and bio-dosimetry of people professionally or accidentally exposed to ionizing radiation. They are applied in addition to the evaluations of the physical dosimetry and they consider the individual radiosensitivity. The main potential risk for humans from exposure to low doses of ionizing radiations is the enhanced incidence of stochastic effects, i.e. carcinogenesis and heritable genetic effects. This report presents a comparative evaluation of the cytogenetic markers for radiation damage of humans and general conclusions of cytogenetic studies of chromosomal aberrations and micronuclei formation in individuals occupationally exposed to action of ionizing radiation. The sensitivity of the methods is compared and their great development and mastering during the last years, as well as the basis of their application - the relation between the frequency of cytogenetic markers observed in lymphocytes in peripheral blood and the risk of malignant disease. The advantages and disadvantages of different cytogenetic techniques are discussed. (author)

  9. Approximate calculational techniques for radiation protection applications (collection of papers presented at the November 1985 American Nuclear Society meeting)

    Energy Technology Data Exchange (ETDEWEB)

    Rice, A.F.; Roussin, R.W. (comps.)

    1986-09-01

    Although radiation protection principles are, on the whole, well understood and a whole series of computer codes exist for their solution, it is felt that there is a need for practical, approximate techniques to be used by the practicing nuclear engineer for a variety of applications. Within the context of approximate techniques, the papers presented cover a broad overview of specific problems, for example, skyshine and penetration analysis, with applications extending from general nuclear reactor design to spent fuel storage and fusion. Separate abstracts have been prepared for individual papers.

  10. Impact of varying lidar measurement and data processing techniques in evaluating cirrus cloud and aerosol direct radiative effects

    Science.gov (United States)

    Lolli, Simone; Madonna, Fabio; Rosoldi, Marco; Campbell, James R.; Welton, Ellsworth J.; Lewis, Jasper R.; Gu, Yu; Pappalardo, Gelsomina

    2018-03-01

    In the past 2 decades, ground-based lidar networks have drastically increased in scope and relevance, thanks primarily to the advent of lidar observations from space and their need for validation. Lidar observations of aerosol and cloud geometrical, optical and microphysical atmospheric properties are subsequently used to evaluate their direct radiative effects on climate. However, the retrievals are strongly dependent on the lidar instrument measurement technique and subsequent data processing methodologies. In this paper, we evaluate the discrepancies between the use of Raman and elastic lidar measurement techniques and corresponding data processing methods for two aerosol layers in the free troposphere and for two cirrus clouds with different optical depths. Results show that the different lidar techniques are responsible for discrepancies in the model-derived direct radiative effects for biomass burning (0.05 W m-2 at surface and 0.007 W m-2 at top of the atmosphere) and dust aerosol layers (0.7 W m-2 at surface and 0.85 W m-2 at top of the atmosphere). Data processing is further responsible for discrepancies in both thin (0.55 W m-2 at surface and 2.7 W m-2 at top of the atmosphere) and opaque (7.7 W m-2 at surface and 11.8 W m-2 at top of the atmosphere) cirrus clouds. Direct radiative effect discrepancies can be attributed to the larger variability of the lidar ratio for aerosols (20-150 sr) than for clouds (20-35 sr). For this reason, the influence of the applied lidar technique plays a more fundamental role in aerosol monitoring because the lidar ratio must be retrieved with relatively high accuracy. In contrast, for cirrus clouds, with the lidar ratio being much less variable, the data processing is critical because smoothing it modifies the aerosol and cloud vertically resolved extinction profile that is used as input to compute direct radiative effect calculations.

  11. An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors

    International Nuclear Information System (INIS)

    Wu Jianzhou; Li Huiling; Shekhar, Raj; Suntharalingam, Mohan; D'Souza, Warren

    2008-01-01

    Purpose: To evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors. Methods and materials: Four SBRT plans were performed for 12 patients with stage I/II non-small-cell lung cancer under the following conditions: (1) conventional margins on free-breathing CT (plan 1), (2) generation of an internal target volume (ITV) using 4DCT with beam delivery under free-breathing conditions (plan 2), (3) gating at end-exhale (plan 3), and (4) gating at end-inhale (plan 4). Planning was performed following the RTOG 0236 protocol with a prescription dose of 54 Gy (3 fractions). For each plan 4D dose was calculated using deformable-image registration. Results: There was no significant difference in tumor dose delivered by the 4 plans. However, compared with plan 1, plans 2-4 reduced total lung BED by 1.9 ± 1.2, 3.1 ± 1.6 and 3.5 ± 2.1 Gy, reduced mean lung dose by 0.8 ± 0.5, 1.5 ± 0.8, and 1.6 ± 1.0 Gy, reduced V20 by 1.5 ± 1.0%, 2.7 ± 1.4%, and 2.8 ± 1.8%, respectively, with p < 0.01. Compared with plan 2, plans 3-4 reduced lung BED by 1.2 ± 1.0 and 1.6 ± 1.5 Gy, reduced mean lung dose by 0.6 ± 0.5 and 0.8 ± 0.7 Gy, reduced V20 by 1.2 ± 1.1% and 1.3 ± 1.5%, respectively, with p < 0.01. The differences in lung BED, mean dose and V20 of plan 4 compared with plan 3 were insignificant. Conclusions: Tumor dose coverage was statistically insignificant between all plans. However, compared with plan 1, plans 2-4 significantly reduced lung doses. Compared with plan 2, plan 3-4 also reduced lung toxicity. The difference in lung doses between plan 3 and plan 4 was not significant

  12. A new on-board imaging treatment technique for palliative and emergency treatments in radiation oncology

    International Nuclear Information System (INIS)

    Held, Mareike

    2016-01-01

    This dissertation focuses on the use of on-board imaging systems as the basis for treatment planning, presenting an additional application for on-board images. A clinical workflow is developed to simulate, plan, and deliver a simple radiation oncology treatment rapidly, using 3D patient scans. The work focuses on an on-line dose planning and delivery process based on on-board images entirely performed with the patient set up on the treatment couch of the linear accelerator. This potentially reduces the time between patient simulation and treatment to about 30 minutes. The basis for correct dose calculation is the accurate image gray scale to tissue density calibration. The gray scale, which is defined in CT Numbers, is dependent on the energy spectrum of the beam. Therefore, an understanding of the physics characteristics of each on-board system is required to evaluate the impact on image quality, especially regarding the underlying cause of image noise, contrast, and non-uniformity. Modern on-board imaging systems, including kV and megavoltage (MV) cone beam (CB) CT as well as MV CT, are characterized in terms of image quality and stability. A library of phantom and patient CT images is used to evaluate the dose calculation accuracy for the on-board images. The dose calculation objective is to stay within 5% local dose differences compared to standard kV CT dose planning. The objective is met in many treatment cases. However, dose calculation accuracy depends on the anatomical treatment site. While on-board CT-based treatments of the head and extremities are predictable within 5% on all systems, lung tissue and air cavities may create local dose discrepancies of more than 5%. The image quality varies between the tested units. Consequently, the CT number-to-density calibration is defined independently for each system. In case of some imaging systems, the CT numbers of the images are dependent on the protocol used for on-board imaging, which defines the imaging dose

  13. A new on-board imaging treatment technique for palliative and emergency treatments in radiation oncology

    Energy Technology Data Exchange (ETDEWEB)

    Held, Mareike

    2016-03-23

    This dissertation focuses on the use of on-board imaging systems as the basis for treatment planning, presenting an additional application for on-board images. A clinical workflow is developed to simulate, plan, and deliver a simple radiation oncology treatment rapidly, using 3D patient scans. The work focuses on an on-line dose planning and delivery process based on on-board images entirely performed with the patient set up on the treatment couch of the linear accelerator. This potentially reduces the time between patient simulation and treatment to about 30 minutes. The basis for correct dose calculation is the accurate image gray scale to tissue density calibration. The gray scale, which is defined in CT Numbers, is dependent on the energy spectrum of the beam. Therefore, an understanding of the physics characteristics of each on-board system is required to evaluate the impact on image quality, especially regarding the underlying cause of image noise, contrast, and non-uniformity. Modern on-board imaging systems, including kV and megavoltage (MV) cone beam (CB) CT as well as MV CT, are characterized in terms of image quality and stability. A library of phantom and patient CT images is used to evaluate the dose calculation accuracy for the on-board images. The dose calculation objective is to stay within 5% local dose differences compared to standard kV CT dose planning. The objective is met in many treatment cases. However, dose calculation accuracy depends on the anatomical treatment site. While on-board CT-based treatments of the head and extremities are predictable within 5% on all systems, lung tissue and air cavities may create local dose discrepancies of more than 5%. The image quality varies between the tested units. Consequently, the CT number-to-density calibration is defined independently for each system. In case of some imaging systems, the CT numbers of the images are dependent on the protocol used for on-board imaging, which defines the imaging dose

  14. PAEA Accreditation Task Force Briefing Paper: Moving Toward Profession-Defined, Outcomes-Based Accreditation.

    Science.gov (United States)

    Bondy, Mary Jo; Fletcher, Sara; Lane, Steven

    2017-12-01

    In anticipation of a revision to the Standards for Accreditation, the Phyisician Assistant Education Association (PAEA) charged a small task force to develop a strategy for engaging its members in the revision process. Rather than focusing on the current Standards, the task force members recommend a backward design approach to determine the desired outcomes of a successful revision to the Standards. Ultimately, the group believes that shifting to a profession-defined, outcomes-based model for accreditation will allow for greater innovation in physician assistant education and reduce the strain on programs facing resource limitations, particularly clinical site shortages. Task force members value accreditation and urge a paradigm shift in the Standards revision process to focus on meaningful educational outcomes that lead to enhanced program quality and patient safety.

  15. Lean-Agile Adaptations in Clinical Laboratory Accredited ISO 15189

    Directory of Open Access Journals (Sweden)

    Carlos Vilaplana Pérez

    2015-12-01

    Full Text Available It’s introduced Lean techniques in a Clinical Laboratory to improve the operability and the efficiency in continuous processes of analysis, failsafe systems, analysis of areas of value pursuit of zero defects and reduction of waste, and it promote continuous improvement in presented difficulties in adapting to the changing needs of the healthcare environment. Whereas it is necessary to incorporate certification and accreditation, note that the adaptability of the clinical laboratory to the changing needs of physicians in obtaining analytical information is reduced. The application of an agile methodology on analytical systems can provide a line of work that allows the incorporation of planning short work cycles on equips quickly with operational autonomy on the basis of demand and respecting the accreditation requirements and flexibility to ensure adequate performance as the intercomparison of results from the different units analytics, analytical quality and turnaround times. Between 2012 and 2014, a process of analysis and improvement was applied to circuits, a 5 s system, transportation of samples, inventory of reactive and samples, motion of personal and samples, reductions of waiting and delays, overproduction, over processing, and defects of results and reports. At last it seems necessary to apply the Agile methodology to adapt to the evolving necessities in time and the different origins of the samples. It’s have used modular systems where the modules of this study are programmed with immunoassay techniques and it has reduced the operative modules depending on the required activity, ensuring the goals of turnaround times, analytic quality, service, health care continuity, and keeping up with the ISO 15189 accreditation requirements. The results of applying the concept of Lean-Agile to a modular system allows us to reduce the associated costs to the seasonal variation of the health care demand and to adapt the system to the changes on

  16. A review of Monte Carlo techniques used in various fields of radiation protection

    International Nuclear Information System (INIS)

    Koblinger, L.

    1987-06-01

    Monte Carlo methods and their utilization in radiation protection are overviewed. Basic principles and the most frequently used sampling methods are described. Examples range from the simulation of the random walk of photons and neutrons to neutron spectrum unfolding. (author)

  17. Possibilities of radiation technique application in machine-building industry of Bulgaria

    International Nuclear Information System (INIS)

    Petrov, A.; Avramov, D.; Kostov, St.

    1979-01-01

    In last ten years, in development of machine-building industry, tendency has been outlined for creation of machines and constructions having minimum weight and elevated reliability from one side due to improvement of design and technology of production and from the other side due to application of materials with improved parameters. Solution of these problems is closely connected with application of the radiation methods. State-of-art of the radiation technology application in the machine-building industry is analyzed and mainly for investigation of wear resistance of friction machineparts. Use of spatial radioactive labelling in investigation of materials and application of radiation methods for optimization of technological processes in metallurgy, foundry and so on is considered. Estimation is give of perspectives of further growth of introduction of radiation methods in Bulgaria [ru

  18. The simple analytical method for scattered radiation calculation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In realization of radiation protection measures for medical staff present during diagnostic procedures, the necessary condition is knowledge of the space - energy distributions of the scattered radiation from the patient. In this paper, the simple calculation procedure for the scattered radiation field of the actual diagnostic energies is presented. Starting from the single Compton scattering model and using the justified transformations the final equations in elementary form are derived. For numerical calculations the computer code ANGIO was created. The calculated results were confirmed by detailed dosimetric measurements of the scattered field around patient (the water phantom) in SSDL in the Institute of nuclear sciences `Vinca`, Belgrade. These results are good base for assessment of irradiation. The main irradiation source for the physician and the other members of the medical team is the back scattered radiation from patient - albedo. (author). 3 figs., 3 refs.

  19. Some techniques and results from high-pressure shock-wave experiments utilizing the radiation from shocked transparent materials

    International Nuclear Information System (INIS)

    McQueen, R.G.; Fritz, J.N.

    1981-01-01

    It has been known for many years that some transparent materials emit radiation when shocked to high pressures. This property was used to determine the temperature of shocked fused and crystal quartz, which in turn allowed the thermal expansion of SiO 2 at high pressure and also the specific heat to be calculated. Once the radiative energy as a function of pressure is known for one material it is shown how this can be used to determine the temperature of other transparent materials. By the nature of the experiments very accurate shock velocities can be measured and hence high quality equation of state data obtained. Some techniques and results are presented on measuring sound velocities from symmetrical impact of nontransparent materials using radiation emitting transparent analyzers, and on nonsymmetrical impact experiments on transparent materials. Because of special requirements in the later experiments, techniques were developed that lead to very high-precision shock-wave data. Preliminary results, using these techniques are presented for making estimates of the melting region and the yield strength of some metals under strong shock conditions

  20. Practical X-ray diagnostics orthopedics and trauma surgery. Indication, adjustment technique and radiation protection

    International Nuclear Information System (INIS)

    Flechtenmacher, Johannes; Sabo, Desiderius

    2014-01-01

    The book on X-ray diagnostics in orthopedics and trauma surgery includes the following chapters: 1. Introduction: radiation protection, equipment technology radiological diagnostics of skeleton carcinomas, specific aspects of trauma surgery, special aspects of skeleton radiology for children. 2. X-ray diagnostics of different anatomical regions: ankle joint, knee, hips and pelvis, hand and wrist joint, elbow, shoulder, spinal cord. 3. Appendix: radiation protection according to the X-ray regulations.

  1. Application of radiation grafting techniques to prepare the high molecular weight water-soluble polymer

    International Nuclear Information System (INIS)

    Le Hai; Nguyen Quoc Hien; Nguyen Tan Man; Truong Thi Hanh; Le Huu Tu; Tran Thi Tam; Pham Thi Sam; Pham Anh Tuan; Le Dinh Lang

    2003-01-01

    The results of the study on the preparation of the high molecular weight water-soluble polymers by radiation grafting and their properties is presented as follows: 1/ by radiation grafting, the molecular weight of PVA was increased 20 times and PAM was increased only 3 times; 2/ the thermal and medium stability of poly(vinyl alcohol) grafted with acrylamide was obviously improved. (LH)

  2. New technique for global solar radiation forecasting by simulated annealing and genetic algorithms using

    International Nuclear Information System (INIS)

    Tolabi, H.B.; Ayob, S.M.

    2014-01-01

    In this paper, a novel approach based on simulated annealing algorithm as a meta-heuristic method is implemented in MATLAB software to estimate the monthly average daily global solar radiation on a horizontal surface for six different climate cities of Iran. A search method based on genetic algorithm is applied to accelerate problem solving. Results show that simulated annealing based on genetic algorithm search is a suitable method to find the global solar radiation. (author)

  3. Detection of the strange bodies on the conveyor belt using gamma radiation technique

    International Nuclear Information System (INIS)

    Barna, A.; Ochiana, G.; Oncescu, M.

    1990-01-01

    The aim of this paper is to present a method for the computation of the activity of a gamma radiation source used in a radiometric assembly designed to detect the strange bodies (iron, stone or wood-made granules) within the textile material on the conveyor belt. The mathematical modelling method based on the Monte Carlo procedure has been used, with different values of the errors of types I and II; the investigation method is the transmission of gamma radiations. (Author)

  4. An intelligent approach for cooling radiator fault diagnosis based on infrared thermal image processing technique

    International Nuclear Information System (INIS)

    Taheri-Garavand, Amin; Ahmadi, Hojjat; Omid, Mahmoud; Mohtasebi, Seyed Saeid; Mollazade, Kaveh; Russell Smith, Alan John; Carlomagno, Giovanni Maria

    2015-01-01

    This research presents a new intelligent fault diagnosis and condition monitoring system for classification of different conditions of cooling radiator using infrared thermal images. The system was adopted to classify six types of cooling radiator faults; radiator tubes blockage, radiator fins blockage, loose connection between fins and tubes, radiator door failure, coolant leakage, and normal conditions. The proposed system consists of several distinct procedures including thermal image acquisition, image pre-processing, image processing, two-dimensional discrete wavelet transform (2D-DWT), feature extraction, feature selection using a genetic algorithm (GA), and finally classification by artificial neural networks (ANNs). The 2D-DWT is implemented to decompose the thermal images. Subsequently, statistical texture features are extracted from the original images and are decomposed into thermal images. The significant selected features are used to enhance the performance of the designed ANN classifier for the 6 types of cooling radiator conditions (output layer) in the next stage. For the tested system, the input layer consisted of 16 neurons based on the feature selection operation. The best performance of ANN was obtained with a 16-6-6 topology. The classification results demonstrated that this system can be employed satisfactorily as an intelligent condition monitoring and fault diagnosis for a class of cooling radiator. - Highlights: • Intelligent fault diagnosis of cooling radiator using thermal image processing. • Thermal image processing in a multiscale representation structure by 2D-DWT. • Selection features based on a hybrid system that uses both GA and ANN. • Application of ANN as classifier. • Classification accuracy of fault detection up to 93.83%

  5. Intraoperative electron beam radiation therapy: technique, dosimetry, and dose specification: report of task force 48 of the radiation therapy committee, American association of physicists in medicine

    International Nuclear Information System (INIS)

    Palta, Jatinder R.; Biggs, Peter J.; Hazle, John D.; Huq, M. Saiful; Dahl, Robert A.; Ochran, Timothy G.; Soen, Jerry; Dobelbower, Ralph R.; McCullough, Edwin C.

    1995-01-01

    Intraoperative radiation therapy (IORT) is a treatment modality whereby a large single dose of radiation is delivered to a surgically open, exposed cancer site. Typically, a beam of megavoltage electrons is directed at an exposed tumor or tumor bed through a specially designed applicator system. In the last few years, IORT facilities have proliferated around the world. The IORT technique and the applicator systems used at these facilities vary greatly in sophistication and design philosophy. The IORT beam characteristics vary for different designs of applicator systems. It is necessary to document the existing techniques of IORT, to detail the dosimetry data required for accurate delivery of the prescribed dose, and to have a uniform method of dose specification for cooperative clinical trials. The specific charge to the task group includes the following: (a) identify the multidisciplinary IORT team, (b) outline special considerations that must be addressed by an IORT program, (c) review currently available IORT techniques, (d) describe dosimetric measurements necessary for accurate delivery of prescribed dose, (e) describe dosimetric measurements necessary in documenting doses to the surrounding normal tissues, (f) recommend quality assurance procedures for IORT, (g) review methods of treatment documentation and verification, and (h) recommend methods of dose specification and recording for cooperative clinical trials

  6. Quality indicators to compare accredited independent pharmacies and accredited chain pharmacies in Thailand.

    Science.gov (United States)

    Arkaravichien, Wiwat; Wongpratat, Apichaya; Lertsinudom, Sunee

    2016-08-01

    Background Quality indicators determine the quality of actual practice in reference to standard criteria. The Community Pharmacy Association (Thailand), with technical support from the International Pharmaceutical Federation, developed a tool for quality assessment and quality improvement at community pharmacies. This tool has passed validity and reliability tests, but has not yet had feasibility testing. Objective (1) To test whether this quality tool could be used in routine settings. (2) To compare quality scores between accredited independent and accredited chain pharmacies. Setting Accredited independent pharmacies and accredited chain pharmacies in the north eastern region of Thailand. Methods A cross sectional study was conducted in 34 accredited independent pharmacies and accredited chain pharmacies. Quality scores were assessed by observation and by interviewing the responsible pharmacists. Data were collected and analyzed by independent t-test and Mann-Whitney U test as appropriate. Results were plotted by histogram and spider chart. Main outcome measure Domain's assessable scores, possible maximum scores, mean and median of measured scores. Results Domain's assessable scores were close to domain's possible maximum scores. This meant that most indicators could be assessed in most pharmacies. The spider chart revealed that measured scores in the personnel, drug inventory and stocking, and patient satisfaction and health promotion domains of chain pharmacies were significantly higher than those of independent pharmacies (p pharmacies and chain pharmacies in the premise and facility or dispensing and patient care domains. Conclusion Quality indicators developed by the Community Pharmacy Association (Thailand) could be used to assess quality of practice in pharmacies in routine settings. It is revealed that the quality scores of chain pharmacies were higher than those of independent pharmacies.

  7. Radiative transfer solutions for coupled atmosphere ocean systems using the matrix operator technique

    International Nuclear Information System (INIS)

    Hollstein, André; Fischer, Jürgen

    2012-01-01

    Accurate radiative transfer models are the key tools for the understanding of radiative transfer processes in the atmosphere and ocean, and for the development of remote sensing algorithms. The widely used scalar approximation of radiative transfer can lead to errors in calculated top of atmosphere radiances. We show results with errors in the order of±8% for atmosphere ocean systems with case one waters. Variations in sea water salinity and temperature can lead to variations in the signal of similar magnitude. Therefore, we enhanced our scalar radiative transfer model MOMO, which is in use at Freie Universität Berlin, to treat these effects as accurately as possible. We describe our one-dimensional vector radiative transfer model for an atmosphere ocean system with a rough interface. We describe the matrix operator scheme and the bio-optical model for case one waters. We discuss some effects of neglecting polarization in radiative transfer calculations and effects of salinity changes for top of atmosphere radiances. Results are shown for the channels of the satellite instruments MERIS and OLCI from 412.5 nm to 900 nm.

  8. Comparing Public Quality Ratings for Accredited and Nonaccredited Nursing Homes.

    Science.gov (United States)

    Williams, Scott C; Morton, David J; Braun, Barbara I; Longo, Beth Ann; Baker, David W

    2017-01-01

    Compare quality ratings of accredited and nonaccredited nursing homes using the publicly available Centers for Medicare and Medicaid Services (CMS) Nursing Home Compare data set. This cross-sectional study compared the performance of 711 Joint Commission-accredited (TJC-accredited) nursing homes (81 of which also had Post-Acute Care Certification) to 14,926 non-Joint Commission-accredited (non-TJC-accredited) facilities using the Nursing Home Compare data set (as downloaded on April 2015). Measures included the overall Five-Star Quality Rating and its 4 components (health inspection, quality measures, staffing, and RN staffing), the 18 Nursing Home Compare quality measures (5 short-stay measures, 13 long-stay measures), as well as inspection deficiencies, fines, and payment denials. t tests were used to assess differences in rates for TJC-accredited nursing homes versus non-TJC-accredited nursing homes for quality measures, ratings, and fine amounts. Analysis of variance models were used to determine differences in rates using Joint Commission accreditation status, nursing home size based on number of beds, and ownership type. An additional model with an interaction term using Joint Commission accreditation status and Joint Commission Post-Acute Care Certification status was used to determine differences in rates for Post-Acute Care Certified nursing homes. Binary variables (eg, deficiency type, fines, and payment denials) were evaluated using a logistic regression model with the same covariates. After controlling for the influences of facility size and ownership type, TJC-accredited nursing homes had significantly higher star ratings than non-TJC-accredited nursing homes on each of the star rating component subscales (P homes with Post-Acute Care Certification performed statistically better on the overall star rating, as well as 3 of the 4 subscales (P homes had statistically fewer deficiencies than non-TJC-accredited nursing homes (P payment denials (P homes

  9. Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer

    International Nuclear Information System (INIS)

    Herrassi, Mohamed Yassine; Bentayeb, Farida; Malisan, Maria Rosa

    2013-01-01

    For the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have been introduced, which are tailored to improve the classic shrinking field technique, as regards both planning target volume (PTV) dose conformality and sparing of OARs, such as parotid glands and spinal cord. In this study, we tested experimentally in a sample of 13 patients, four of these advanced 3DCRT techniques, all using photon beams only and a unique isocentre, namely Bellinzona, Forward-Planned Multisegments (FPMS), ConPas, and field-in-field (FIF) techniques. Statistical analysis of the main dosimetric parameters of PTV and OARs DVHs as well as of homogeneity and conformity indexes was carried out in order to compare the performance of each technique. The results show that the PTV dose coverage is adequate for all the techniques, with the FPMS techniques providing the highest value for D95%; on the other hand, the best sparing of parotid glands is achieved using the FIF and ConPas techniques, with a mean dose of 26 Gy to parotid glands for a PTV prescription dose of 54 Gy. After taking into account both PTV coverage and parotid sparing, the best global performance was achieved by the FIF technique with results comparable to that of IMRT plans. This technique can be proposed as a valid alternative when IMRT equipment is not available or patient is not suitable for IMRT treatment. (author)

  10. A modified technique for craniospinal irradiation in children designed to reduce acute and late radiation toxicity

    International Nuclear Information System (INIS)

    Phillips, Claire; Sexton, Maree

    2004-01-01

    Craniospinal irradiation is an important technique for the treatment of a number of paediatric malignancies. The conventional technique uses photons for all fields and does not exploit the benefits of CT and computer planning systems. The present paper describes a modification of the conventional technique in which both photons and electrons are used for the spinal field (mixed-beam technique). Computed tomography images and a planning computer are used for the selection of field junctions, electron beam energy and dosimetry. The intention of the technique is to reduce radiotherapy toxicity. A discussion of the potential benefits is presented Copyright (2004) Blackwell Publishing Asia Pty Ltd

  11. Study on grafting of monomer onto natural rubber latex by radiation technique

    International Nuclear Information System (INIS)

    Nguyen Tan Man; Le Hai; Tran Thi Tam; Le Huu Tu, Pham Thi Sam; Dao Minh Phuong; Ha Thuc Huy

    2004-01-01

    Radiation vulcanization of natural rubber latex has been extensively developed through programmers assisted by the IAEA and UNDP under RCA in Asia and Pacific Region. R-D has been done in most of the Member States with technical assistance from Japan's Takasaki Radiation Chemistry Establishment. Radiation vulcanized natural rubber latex (RVNRL) has many advantages over the conventional sulfur vulcanized latex, such as absence of nitrosamine and low cytotoxicity. Radiation crosslinking is a room temperature process, itself an important cost advantage, it is easily controlled and desired extend of crosslinking is easily achieved by controlling the dose (irradiation time). Disadvantages of RVNRL to be improved are poor physical properties of film such as low tensile strength and tear strength. The research groups of Japan, Thailand and Indonesia concentrated on the improvement of physical properties of RVNRL using radiation grafted PMMA as additive [2]. F. Sundardi and W. Sofiarti have reported that tensile strength and hardness increased by radiation grafting of styrene onto NR [5]. Ono et al have reported the grafting of MMA onto NR by gamma irradiation at a dose of 5 kGy for producing thermoplastic elastomers [4]. The objective of this project is to report the results of studies of radiation graft-copolymerization of methyl methacrylate (MMA) or styrene (St) onto natural rubber latex in order to improve their physico-mechanical properties and evaluation of grafted material using Small-Angle Neutron Scattering through FNCA Project. The grafting degree of MMA and St onto NR increased with the increase of irradiation dose and monomer concentration. The alteration of grafted products structure was determined by IR method. Tensile strength, Shore A hardness, 100% modulus of grafted products increased with the increase of monomer concentration and irradiation dose while elongation at break decreased. The grafted products were characterized by Transmission Electron

  12. Shaping performance: do international accreditations and quality management really help?

    OpenAIRE

    Nigsch, Stefano; Schenker-Wicki, Andrea

    2012-01-01

    In recent years, international accreditations from private providers have gained importance among business schools all over the world. Higher education managers increasingly see these accreditations as a way of assuring and developing quality in order to comply with international standards, enhance performance, and increase reputation. However, given that an accreditation process requires a great deal of resources and that it might increase bureaucratization and control, international accredi...

  13. Treatment of waste water by a combined technique of radiation and conventional method

    International Nuclear Information System (INIS)

    Sakumoto, A.; Miyata, T.

    1984-01-01

    Treatment of waste water by radiation in combination with a conventional method such as biological oxidation, coagulation with Fe 2 (SO 4 ) 3 , and ozonation has been studied for reducing necessary dose. Ethylene glycol ethers, polyoxyethylene n-nonyl phenyl ether (NPE), polyvinyl alcohol (PVA), ethylene glycol, phenol, and oxalic acid were used as a model pollutant. The combined use of radiation and biological oxidation markedly improved the removal of TOC in aqueous oxygenated solution of ethylene glycol ethers. The combined use of radiation and coagulation had remarkable effects on the reduction of TOC in aqueous deoxygenated solution of NPE or PVA. The simultaneous use of radiation and ozone gave a synergistic effect on oxidative degradation of organic pollutants. The synergistic effect was suggested to arise from chain reactions having a powerful oxidizing agent (OH radical). The rate of TOC removal by the process depended on dose rate. Aqueous solution of 150 mg/l oxalic acid was treated by the combined use of electron beams and ozone using a new type of irradiation vessel to reduce TOC with G(-TOC) of 87 at 2.3 x 10 7 rad/h. The simultaneous use of radiation and ozone is superior to the removal of TOC by other combined methods and can be applied irrespective of the type of organic matter. (author)

  14. Techniques for detecting and determining risks from low-level radiation

    International Nuclear Information System (INIS)

    Boice, J.D.

    1980-01-01

    Epidemiology is the study of disease in man. In evaluating radiation hazards, analytic studies have utilized the cohort type of investigation (where persons exposed and not exposed to radiation are followed forward in time for determination of disease experience) or case-control approaches (where persons with and without a specific disease are evaluated for previous exposure to radiation). Most radiation studies have evaluated cohorts (e.g., radiologists), although important case-control studies have been conducted (e.g., childhood leukemia as related to prenatal x ray). At its best, epidemiology is capable fo evaluating relative risks (RR) on the order of 1.4 (i.e., a 40% relative excess). However, the RRs of interest following low doses of radiation (1 rad) are on the order of 1.02-1.002. Thus, not much should be anticipated from direct observations at 1 rad, and indirect approaches must be taken to estimate low-dose effects. Such indirect approaches include evaluating 1) populations exposed to a range of doses, both low and high, where interpolation models can be reasonably applied to estimate low-dose effects; and 2) populations exposed to fractionated doses over a long period of time where the resulting dose-effect relationship theoretically should be linear and the estimation of low-level health effects facilitated

  15. The DOE Laboratory Accreditation Program 8 years later

    International Nuclear Information System (INIS)

    Cummings, R.; Kershisnik, R.; Taylor, T.; Grothaus, G.; Loesch, R.M.

    1994-01-01

    The DOE Laboratory Accreditation Program was implemented in 1986. Currently, the program is conducting its seventeenth performance testing session for whole body personnel dosimeters. All but two DOE laboratories have gained accreditation for their whole body personnel dosimetry systems. Several test situations which were anticipated in the early stages of DOELAP have not materialized. In addition, the testing standard for whole body personnel dosimetry systems is under review and revision. In the near future, the accreditation programs for extremity dosimetry and bioassay will be implemented. This presentation summarizes the status and anticipated direction of the DOE whole body and extremity dosimetry and bioassay laboratory accreditation program

  16. Accreditation and participatory design in the healthcare sector

    DEFF Research Database (Denmark)

    Simonsen, Jesper; Scheuer, John Damm; Hertzum, Morten

    2015-01-01

    , realizing, and measuring the effects from using an information technology. This approach aligns with much of the logic in accreditation but is distinguished by its focus on effects, whereas current accreditation approaches focus on processes. Thereby, effects-driven IT development might support challenging...... parts of the accreditation process and fit well with clinical evidence-based thinking. We describe and compare effects-driven IT development with accreditation, in terms of the Danish Quality Model which is used throughout the Danish healthcare sector, and we discuss the prospects and challenges...

  17. A Perspective on the Accreditation of Nontraditional Higher Education.

    Science.gov (United States)

    Andrews, Grover; Harris, John

    1979-01-01

    The nontraditional education movement in postsecondary education has presented new problems for accreditation in terms of results vs process, governance, the rise of entrepreneurs, and territoriality. (JMF)

  18. The impact of central lung distance, maximal heart distance, and radiation technique on the volumetric dose of the lung and heart for intact breast radiation

    International Nuclear Information System (INIS)

    Kong, F.-M.; Klein, Eric E.; Bradley, Jeffrey D.; Mansur, David B.; Taylor, Marie E.; Perez, Carlos A.; Myerson, Robert J.; Harms, William B.

    2002-01-01

    Purpose: To investigate the impact of radiographic parameter and radiation technique on the volumetric dose of lung and heart for intact breast radiation. Methods and Materials: Forty patients with both two-dimensional (2D) and computed tomographic (CT) simulations were enrolled in the study. Central lung distance (CLD), maximal heart distance (MHD), and maximal heart length (MHL) were measured under virtual simulation. Four plans were compared for each patient. Plan A used a traditional 2D tangential setup. Plan B used clinical target volume (CTV) based three-dimensional (3D) planning. Both plans C and D used a combination of a medial breast field with shallow tangents. Plan D is a further modification of plan C. Results: Under the traditional tangential setup, the mean ipsilateral lung dose and volume at 20, 30, and 40 Gy correlated linearly with CLD (R = 0.85∼0.91). The mean ipsilateral lung dose (Gy) approximated 4 times the CLD value (cm), whereas the percentage volume (%) of ipsilateral lung at 20, 30, and 40 Gy was about 10 times the CLD (cm). The mean heart dose and percentage volume at 20, 30, and 40 Gy correlated with MHD (R = 0.76∼0.80) and MHL (R 0.65∼0.75). The mean heart dose (Gy) approximated 3 times the MHD value (cm), and the percentage volume (%) of the heart at 10, 20, 30, and 40 Gy was about 6 times MHD (cm). Radiation technique impacted lung and heart dose. The 3D tangential plan (plan B) failed to reduce the volumetric dose of lung and heart from that of the 2D plan (plan A). The medial breast techniques (plans C and D) significantly decreased the volume of lung and heart receiving high doses (30 and 40 Gy). Plan D further decreased the 20 Gy volumes. By use of the medial breast technique, the lung and heart dose were not impacted by original CLD and MHD/MHL. Therefore, the improvement from the tangential technique was more remarkable for patients with CLD ≥ 3.0 cm (p<0.001). Conclusions: The CLD and MHD impact the volumetric dose of

  19. The development of gamma energy identify algorithm for compact radiation sensors using stepwise refinement technique

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Hyun Jun [Div. of Radiation Regulation, Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Kim, Ye Won; Kim, Hyun Duk; Cho, Gyu Seong [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Yi, Yun [Dept. of of Electronics and Information Engineering, Korea University, Seoul (Korea, Republic of)

    2017-06-15

    A gamma energy identifying algorithm using spectral decomposition combined with smoothing method was suggested to confirm the existence of the artificial radio isotopes. The algorithm is composed by original pattern recognition method and smoothing method to enhance the performance to identify gamma energy of radiation sensors that have low energy resolution. The gamma energy identifying algorithm for the compact radiation sensor is a three-step of refinement process. Firstly, the magnitude set is calculated by the original spectral decomposition. Secondly, the magnitude of modeling error in the magnitude set is reduced by the smoothing method. Thirdly, the expected gamma energy is finally decided based on the enhanced magnitude set as a result of the spectral decomposition with the smoothing method. The algorithm was optimized for the designed radiation sensor composed of a CsI (Tl) scintillator and a silicon pin diode. The two performance parameters used to estimate the algorithm are the accuracy of expected gamma energy and the number of repeated calculations. The original gamma energy was accurately identified with the single energy of gamma radiation by adapting this modeling error reduction method. Also the average error decreased by half with the multi energies of gamma radiation in comparison to the original spectral decomposition. In addition, the number of repeated calculations also decreased by half even in low fluence conditions under 104 (/0.09 cm{sup 2} of the scintillator surface). Through the development of this algorithm, we have confirmed the possibility of developing a product that can identify artificial radionuclides nearby using inexpensive radiation sensors that are easy to use by the public. Therefore, it can contribute to reduce the anxiety of the public exposure by determining the presence of artificial radionuclides in the vicinity.

  20. Comparison of two different techniques on the human lymphocytes morphology and sensitivity to gamma radiation

    International Nuclear Information System (INIS)

    Kol, R.

    1985-02-01

    The lymphocytes in the peripheral blood are divided into two main subclasses: T cells and B cells. These differ from each other in function and in their sensitivity to radiation. The effort to study which group is more sensitive to radiation has resulted in many contradictory results. In the present study we examined whether the methods that are used to separate the lymphocytes from the whole blood, before their separation into subclasses, have an effect on the cells and whether this might contribute to the contradictory results. Blood samples were taken from several normal donors and each sample was devided into two fractions. Lymphocytes in each fraction were separated by one of the two following methods: a) sedimentation of erythrocytes by gravitation; b) separation on Ficoll-Paque density gradient. For cells obtained by these two methods, the ultrastructure was examined by electron microscopy and their ability to incorporate radioactive thymidine was measured. Samples separated on Ficoll-Paque showed a subpopulation with morphological changes similar to those occuring in lymphocytes undergoing stimulation. Unstimulated cells separated on Ficoll-Paque showed greater sensitivity to radiation. The effect of gamma radiation on the capability of lymphocytes to undergo transformation in response to three mitogens; PHA, PWM and Con A was examined. Different mitogens stimulate different lymphocytes subpopulations. There was no difference between the two separation methods regarding the sensitivity to gamma radiation of stimulation by PAH and PWM. The transformation by Con A of lymphocytes separated on Ficoll-Paque was more radiosensitive. This could indicate that the separation by Ficoll-Paque density gradient causes a selective depletion of T lymphocytes that react with Con A and are considered more radioresistant. The use of different methods for separating lymphocytes from whole blood- each has a different influence on the cells- can contribute to contradictory

  1. Main error sources in sorbtion technique and plasma electron component parameter definition by continuous X radiation

    International Nuclear Information System (INIS)

    Gavrilov, V.V.; Torokhova, N.V.; Fasakhov, I.K.

    1986-01-01

    Recombination radiation effect on the relation of signals behind the filters depending on the plasma temperature(sorption method for T determination) is demonstrated. This factor produces the main effect on the method accuracy (100-400%), the other factors analysed in combination make an error in temperature at the level of 50%. Method of plasma electron distribution function reconstruction by continuous x-radiation spectrum, based on the correctness (under certain limitations for the required function) of the equation, linking the electron distribution function with bremmsstrahlung spectral density is presented

  2. The incidence of breast cancer following mantle field radiation therapy as a function of dose and technique

    International Nuclear Information System (INIS)

    Tinger, Alfred; Wasserman, Todd H.; Klein, Eric E.; Miller, Elizabeth A.; Roberts, Tracy; Piephoff, James V.; Kucik, Nancy A.

    1997-01-01

    Purpose: There is an increased incidence of breast cancer following mantle field radiation therapy for Hodgkin's disease (HD). We reviewed the experience at the Mallinckrodt Institute of Radiology (MIR) for radiation factors related to the development of breast cancer after mantle field radiation therapy for HD. Methods: The radiation therapy records of 152 women treated with mantle field irradiation for HD at MIR between 1966-1985 were reviewed for the development of breast cancer and treatment-related factors. All patients had a minimum of 5 years of follow-up. The treatment era (1966-1974 vs. 1975-1985), stage of HD, mediastinal dose, axillary dose, maximum dose from the anterior field (anterior d max dose), the anterior-posterior:posterior-anterior (AP:PA) ratio, age at the time of treatment, length of follow-up, and history of splenectomy were analyzed as possible contributing factors for the development of breast cancer. The observed number of breast cancers was compared to the expected number based on age-adjusted incidences from the Connecticut Tumor Registry. Results: Ten breast cancers occurred in the population. Eight involved an upper outer quadrant. In a multivariate analysis, the development of breast cancer was significantly associated with axillary dose. Patients in the early treatment era were at an increased risk for the development of breast cancer due to high anterior d max and breast doses from weighting the fields anteriorly on a low energy linear accelerator. The use of current radiation therapy techniques was not related to an increased risk of breast cancer with a median follow-up of 13 years. Conclusions: A high dose to the axilla and the anterior d max point is significantly associated with the development of breast cancer after mantle field irradiation for HD. Efforts to protect the breast from high doses will likely lessen the increased risk of breast cancer in women treated with radiation therapy for HD

  3. Dosimetry for radiation processing. Final report of the co-ordinated research project on characterization and evaluation of high dose dosimetry techniques for quality assurance in radiation processing

    International Nuclear Information System (INIS)

    2000-06-01

    In many Member States the use of large cobalt-60 gamma ray facilities and electron beam accelerators with beam energies from about 0.1 to 10 MeV for industrial processing continues to increase. For these processes, quality assurance relies on the application of well established dosimetry systems and procedures. This is especially the case for health regulated processes, such as the radiation sterilization of health care products, and the irradiation of food to eliminate pathogenic organisms or to control insect pests. A co-ordinated research project (CRP) was initiated by the IAEA in June 1995. Research contracts and research agreements in areas of high dose dosimetry were initiated to meet these challenges. The major goals of this CRP were to investigate the parameters that influence the response of dosimeters and to develop reference and transfer dosimetry techniques, especially for electron beams of energy less than 4 MeV and for high energy X ray sources (up to 5 MV). These will help to unify the radiation measurements performed by different radiation processing facilities and other high dose dosimetry users in Member States and encourage efforts to obtain traceability to primary and secondary standards laboratories. It will also aim to strengthen and expand the present International Dose Assurance Service (IDAS) provided by the IAEA

  4. Calibration Laboratory for Medical Physics towards ISO/ IEC 17025 accreditation: Experience and challenges

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Abdul Aziz Ramli; Muhammad Jamal Isa; Sharul Azlan Azizan

    2011-01-01

    Medical Physics Calibration Laboratory is laboratory where placed under Medical Physics Group, Radiation Healthy and Safety Division. This laboratory offers calibration services to their customers that covered doses calibration, tube voltan (kVp), exposure doses, sensitometer and densitometer. After 12 years of operation, it is the right time for this laboratory to upgrade their quality services based on ISO/ IEC 17025. Accreditation scope covered calibration for diagnostic doses only. Starting from 2009, serious effort was done to prepare the quality documents that covered quality manual, quality procedure and work orders. Meanwhile, several series of audit were done by Quality Management Center (QMC), now Innovation Management Center (IMC) with collaboration with Standard Department. This paper works revealed challenges and experience during the process toward ISO/ IEC 17025 accreditation. (author)

  5. Quality management system and accreditation of the in vivo monitoring laboratory at Karslruhe Institute of Technology.

    Science.gov (United States)

    Breustedt, B; Mohr, U; Biegard, N; Cordes, G

    2011-03-01

    The in vivo monitoring laboratory (IVM) at Karlsruhe Institute of Technology (KIT), with one whole body counter and three partial-body counters, is an approved lab for individual monitoring according to German regulation. These approved labs are required to prove their competencies by accreditation to ISO/IEC 17025:2005. In 2007 a quality management system (QMS), which was successfully audited and granted accreditation, was set up at the IVM. The system is based on the ISO 9001 certified QMS of the central safety department of the Research Centre Karlsruhe the IVM belonged to at that time. The system itself was set up to be flexible and could be adapted to the recent organisational changes (e.g. founding of KIT and an institute for radiation research) with only minor effort.

  6. Interlaboratory comparison and accreditation in quality control testing of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Kepler, K.; Vladimirov, A.; Servomaa, A.

    2005-01-01

    The Univ. of Tartu provides a quality control service to the majority of diagnostic X-ray departments in Estonia. Its methodology has been adopted from the IEC and other relevant standards. Recently the Testing Centre of the Univ. of Tartu was accredited on this methodology by ISO/IEC 17025. Besides the implementation of the quality management system, participation in interlaboratory comparison (ILC) was one of the prerequisites for the accreditation. Tests for estimating reproducibility of tube voltage and dose rate, accuracy of the voltage and accuracy of exposure time were carried out on a diagnostic X-ray unit in the Radiation and Nuclear Safety Authority in Helsinki. The measurement performance was judged by calculating deviation En normalised with respect to the stated uncertainties. En values for all tests were less than unity and by the common ILC criteria the testing performance could be considered as acceptable. (authors)

  7. Testing the assessment of new radiation oncology technology and treatments framework using the evaluation of post-prostatectomy radiotherapy techniques

    International Nuclear Information System (INIS)

    Duchesne, Gillian M.; Haworth, Annette; Hornby, Colin; Bone, Eric; Carter, Hannah; Martin, Andrew; Ebert, Martin A.; Gagliardi, Frank; Gibbs, Adrian; Sidhom, Mark; Wood, Maree; Jackson, Michael

    2016-01-01

    We tested the ability of the Assessment of New Radiation Oncology Technology and Treatments framework to determine the clinical efficacy and safety of intensity-modulated radiation therapy (IMRT) compared with 3-dimensional radiation therapy (3DCRT) for post-prostatectomy radiation therapy (PPRT) to support its timely health economic evaluation. Treatment plans produced using FROGG guidelines provided dosimetry parameters for both techniques at 64 Gy and 70 Gy and were also used to model early and late outcome probabilities. Clinical parameters were derived from early toxicity and quality of life patient data, systematic literature review and expert opinion. Dosimetry parameters were correlated with the measures of clinical efficacy and safety. Data from two patient cohorts (29 and 27 respectively) were collected within the project timeframe, providing evidence for acute toxicity and quality of life, and dosimetric comparisons. Relative rates of tumour control probability (TCP) and normal tissue control probability (NTCP) modelling were readily derived from the planning exercise and demonstrated advantages in uncomplicated TCP for IMRT over 3DCRT, predominantly due to normal tissue sparing. The safety of IMRT delivery was demonstrated with TCP uncompromised by IMRT protocol violations, which achieved rectal sparing only by reducing minimum target dose and coverage. Sources of desk-top and patient-based evidence were successfully used to demonstrate potential improved clinical efficacy and safety of applying dose escalation using IMRT instead of 3DCRT in PPRT.

  8. Some problems in methodology of economjc evaluation of radiation technique quality

    International Nuclear Information System (INIS)

    Kodyukov, V.M.; Purtova, M.I.; Sokolova, Z.I.; Smirnova, Z.M.

    1976-01-01

    The quality of radiation equipment (RE) should essentially be assessed when designing, standardizing, planning, and evaluating the cost and economy of RE. The basic factors are sited upon which subsequent economic assessment of quality levels were based. It also discusses the specifics involved in determining the principal quality factors for radioisotopic flaw-detection equipment and gamma-therapeutic instruments

  9. Application of correlation techniques to the angular spectrum of scattered radiation from tokamak plasmas

    International Nuclear Information System (INIS)

    Nazikian, R.

    1990-01-01

    In the limit of the first Born approximation for a partially coherent secondary source consisting of a spatially random plasma illuminated by a coherent plane wave, it is shown that the spectral coherence of the scattered radiation conveys information on the three-dimensional intensity distribution of the secondary source

  10. Experimental techniques for the study of radiation damage in metals and alloys

    International Nuclear Information System (INIS)

    Novion, C.H. de.

    1983-06-01

    In this review, one presents the main experimental techniques used to study point defects and defect clusters introduced by irradiation in metals and alloys; emphasis will be put on some recent techniques. In particular, the studies allowing to analyse the very small agglomerates of point defects (Huang and small angle scattering, positron annihilation, electron microscopy) will be compared [fr

  11. Quality assurance in the measurement of internal radioactive contamination and dose assessment and the United States Department of Energy Laboratory Accreditation Program

    International Nuclear Information System (INIS)

    Bhatt, Anita

    2016-01-01

    The Quality Assurance for analytical measurement of internal radioactive contamination and dose assessment in the United States (US) is achieved through the US Department of Energy (DOE) Laboratory Accreditation Program (DOELAP) for both Dosimetry and Radio bioassay laboratories for approximately 150,000 radiation workers. This presentation will explain the link between Quality Assurance and the DOELAP Accreditation process. DOELAP is a DOE complex-wide safety program that ensures the quality of worker radiation protection programs. DOELAP tests the ability of laboratories to accurately measure and quantify radiation dose to workers and assures the laboratories quality systems are capable of defending and sustaining their measurement results. The United States Law in Title 10 of the Code of Federal Regulations 835 requires that personnel Dosimetry and Radio bioassay programs be tested and accredited

  12. The main indicators for iranian hospital ethical accreditation

    Directory of Open Access Journals (Sweden)

    SEYED ALI ENJOO

    2015-07-01

    Full Text Available Introduction: The application of organizational ethics in hospitals is one of the novel ways to improve medical ethics. Nowadays achieving efficient and sufficient ethical hospital indicators seems to be inevitable. In this connection, the present study aims to determine the best indicators in hospital accreditation. Methods: 69 indicators in 11 fields to evaluate hospital ethics were achieved through a five-step qualitative and quantitative study including literature review, expert focus group, Likert scale survey, 3 rounded Delphi, and content validity measurement. Expert focus group meeting was conducted, employing Nominal Group Technique (NGT. After running NGT, a three rounded Delphi and parallel to Delphi and a Likert scale survey were performed to obtain objective indicators for each domain. The experts were all healthcare professionals who were also medical ethics researchers, teachers, or Ph.D students. Content validity measurements were computed, using the viewpoints of two different expert groups, some ethicists, and some health care professionals (n=46. Results: After conducting NGT, Delphi, Likert survey, 11 main domains were listed including: Informed consent, Medical confidentiality, Physician-patient economic relations, Ethics consultation policy in the hospital, Ethical charter of hospital, Breaking bad medical news protocol, Respect for the patients’ rights, Clinical ethics committee, Spiritual and palliative care unit programs in the hospitals, Healthcare professionals’ communication skills, and Equitable access to the healthcare. Also 71 objective indicators for these 11 domains were listed in 11 tables with 5 to 8 indicators per table. Content Validity Ratio (CVR measurements were done and 69 indicators were highlighted. Conclusion: The domains listed in this study seem to be the most important ones for evaluating hospital ethics programs and services. Healthcare organizations’ accreditation and ranking are crucial for

  13. Study of the gamma radiation effect on lincomycin by two techniques thermal analysis and fourier transform infrared (FTIR)

    International Nuclear Information System (INIS)

    Al-Zier, A.; Al-Kassiri, H.; Al Aji, Z.

    1999-02-01

    Sample of Lincomycin were irradiated by means of gamma radiation ( 60 Co) at dose rate ca. (408 kGy/h) in the range (3, 5, 15, 20)kGy in presence of air. Samples were investigated using two techniques: Thermal analysis (Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG)) and Fourier Transform Infrared (FTIR). DSC purity study, which depends on Vant Hof equation, showed that the purity of Lincomycin reduced by means of gamma radiation. The purity of theses samples decreased by increasing the dose, and the purity of lincomycin was still above (99%) at dose (10 kGy). To follow up this effects, (FTIR) spectrums of these sample were recorded before and after irradiation. The two peaks at (1500 - 1750 Cm -1 ) which belong to amide group, and the peak at (1050 - 1100 Cm -1 ) which belongs to the S-C groups have reduced. (author)

  14. Study of the gamma radiation effect on the lincomycin by two techniques thermal analysis and fourier transform infrared (FTIR)

    International Nuclear Information System (INIS)

    Al-Zier, A.; Al-Kassiri, H.

    1999-01-01

    Sample of Lincomycin were irradiated by means of gamma radiation ( 60 Co) at dose rate ca. (408 kGy/h) in the range (3, 5, 15, 20)kGy in presence of air. Samples were investigated using two techniques: Thermal analysis (Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG)) and Fourier Transform Infrared (FTIR). DSC purity study, which depends on Vant Hof equation, showed that the purity of Lincomycin reduced by means of gamma radiation. The purity of theses samples decreased by increasing the dose, and the purity of lincomycin was still above (99%) at dose (10 kGy). To follow up this effects, (FTIR) spectrums of these sample were recorded before and after irradiation. The two peaks at (1500 - 1750 Cm -1 ) which belong to amide group, and the peak at (1050 - 1100 Cm -1 ) which belongs to the S-C groups have reduced. (author)

  15. Layout techniques to enhance the radiation tolerance of standard CMOS technologies demonstrated on a pixel detector readout chip

    CERN Document Server

    Snoeys, W; Burns, M; Campbell, M; Cantatore, E; Carrer, N; Casagrande, L; Cavagnoli, A; Dachs, C; Di Liberto, S; Formenti, F; Giraldo, A; Heijne, Erik H M; Jarron, Pierre; Letheren, M F; Marchioro, A; Martinengo, P; Meddi, F; Mikulec, B; Morando, M; Morel, M; Noah, E; Paccagnella, A; Ropotar, I; Saladino, S; Sansen, Willy; Santopietro, F; Scarlassara, F; Segato, G F; Signe, P M; Soramel, F; Vannucci, Luigi; Vleugels, K

    2000-01-01

    A new pixel readout prototype has been developed at CERN for high- energy physics applications. This full mixed mode circuit has been implemented in a commercial 0.5 mu m CMOS technology. Its radiation tolerance has been enhanced by designing all NMOS transistors in enclosed geometry and introducing guardrings wherever necessary. The technique is explained and its effectiveness demonstrated on various irradiation measurements on individual transistors and on the prototype. Circuit performance started to degrade only after a total dose of 600 krad-1.7 Mrad depending on the type of radiation. 10 keV X-rays, /sup 60/Co gamma-rays, 6.5 MeV protons, and minimum ionizing particles were used. Implications of this layout approach on the circuit design and perspectives for even deeper submicron technologies are discussed. (20 refs).

  16. Reduction of radiation doses in leg lengthening procedures by means of audit and computed tomography scanogram techniques

    International Nuclear Information System (INIS)

    Romanowski, C.A.J.; Sprigg, A.; Underwood, A.C.

    1994-01-01

    Children with congenital bone dysplasias may benefit from leg lengthening procedures. Such procedures, by necessity, require frequent and regular imaging. It is necessary to minimize the total radiation dose to these patients, and particularly the dose to the gonads. In the present study, the films of 13 patients who had completed leg lengthening procedures were reviewed. The number of films was assessed together with the use of appropriate gonad shielding. In a second part of the study, thermoluminescent dosemeter measurements of radiation doses to a phantom were made for both plain radiographs (with and without gonad protection) and computed tomography (CT) scanograms. The results show that audit plays an important role in assessing radiographic practice with respect to accurate placement of gonad protection and confirm that a significant dose reduction can be accomplished by careful use of this lead shielding. Dose reduction can also be achieved by using alternative radiographic techniques such as CT scanograms. (author)

  17. Comparison among the scintillation and electrets techniques for emission of alpha radiation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.; Gammage, R.B.

    2005-01-01

    A comparison of the scintillation and of electret techniques for measurement of Uranium, Plutonium and transuranic elements in low level radioactivity is presented in this work. The samples of material to measure were obtained by the Research Department of the Oak Ridge National Laboratory (ORNL) of contaminated soils by radioactive material of plutonium and other transuranic elements. The samples in both techniques were measured to infinite thickness. The electret E - PERM of Rad Elec. Inc.; it was the available selected detector in 1993 and the measures with this technique were carried out by the Dr. R. B. Gammage and the Dr. K. E. Meyer of the Health and Safety Research Division of ORNL. The scintillation technique for measurement of the samples up mentioned it was carried out by the Dr. Augusto Moreno y Moreno in the facilities of DOSAR of ORNL. The comparative results of the two techniques agree just as it is shown in this work; but the scintillation technique offers the advantage of a considerable reduction of the exposure time and reading of the samples - electret, if it is compared with the immediate measurement of the scintillation technique that is described in this work. (Author)

  18. A hybrid method based on a new clustering technique and multilayer perceptron neural networks for hourly solar radiation forecasting

    International Nuclear Information System (INIS)

    Azimi, R.; Ghayekhloo, M.; Ghofrani, M.

    2016-01-01

    Highlights: • A novel clustering approach is proposed based on the data transformation approach. • A novel cluster selection method based on correlation analysis is presented. • The proposed hybrid clustering approach leads to deep learning for MLPNN. • A hybrid forecasting method is developed to predict solar radiations. • The evaluation results show superior performance of the proposed forecasting model. - Abstract: Accurate forecasting of renewable energy sources plays a key role in their integration into the grid. This paper proposes a hybrid solar irradiance forecasting framework using a Transformation based K-means algorithm, named TB K-means, to increase the forecast accuracy. The proposed clustering method is a combination of a new initialization technique, K-means algorithm and a new gradual data transformation approach. Unlike the other K-means based clustering methods which are not capable of providing a fixed and definitive answer due to the selection of different cluster centroids for each run, the proposed clustering provides constant results for different runs of the algorithm. The proposed clustering is combined with a time-series analysis, a novel cluster selection algorithm and a multilayer perceptron neural network (MLPNN) to develop the hybrid solar radiation forecasting method for different time horizons (1 h ahead, 2 h ahead, …, 48 h ahead). The performance of the proposed TB K-means clustering is evaluated using several different datasets and compared with different variants of K-means algorithm. Solar datasets with different solar radiation characteristics are also used to determine the accuracy and processing speed of the developed forecasting method with the proposed TB K-means and other clustering techniques. The results of direct comparison with other well-established forecasting models demonstrate the superior performance of the proposed hybrid forecasting method. Furthermore, a comparative analysis with the benchmark solar

  19. Investigation of individual radiation exposures from discharges to the aquatic environment: techniques used in habits surveys

    International Nuclear Information System (INIS)

    Leonard, D.R.P.; Hunt, G.J.; Jones, P.G.W.

    1982-01-01

    The techniques used by the Fisheries Radiobiological Laboratory (FRL) in conducting habits surveys are described and discussed. The main objectives of these surveys are to investigate exposure pathways to the public resulting from radioactive discharges to the aquatic environment and to provide the basic data from which critical groups can be identified. Preparation, conduct and interpretation of the results of surveys are described and possible errors obtained by the interview technique are highlighted. A means of verifying the results of interviews by a logging technique has been devised and some comparative results are presented. (author)

  20. How changing quality management influenced PGME accreditation: a focus on decentralization and quality improvement

    NARCIS (Netherlands)

    Akdemir, Nesibe; Lombarts, Kiki M. J. M. H.; Paternotte, Emma; Schreuder, Bas; Scheele, Fedde

    2017-01-01

    Background: Evaluating the quality of postgraduate medical education (PGME) programs through accreditation is common practice worldwide. Accreditation is shaped by educational quality and quality management. An appropriate accreditation design is important, as it may drive improvements in training.