WorldWideScience

Sample records for accessory drive device

  1. Electric accessory drives in automobiles. Elektrische Hilfsantriebe in Kraftfahrzeugen

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-01

    Ten lectures were presented on the conference ''Electric accessory drives in automobiles'' subjects: - Survey on electric accessory drives in automobiles; cooperation of generator, battery and starter; technical solution of accessory drives, considerations on a system; comparison of various solutions for drives by viewing the example of a headlight vertical aim control; wiper motors and their control; blowers for heating, ventilation and air conditioning in automobiles; criteria for dimensioning of blower motors; drives in heating and air-conditioning applicances; permanent magnets for engine excitation; systematic quality assurance of electric accessory drives from car-development to serial production. Numerous illustrations and formulas are supplied which illustrate and explain the lectures. Each lecture is abstracted individually.

  2. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  3. 21 CFR 868.5860 - Pressure tubing and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pressure tubing and accessories. 868.5860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5860 Pressure tubing and accessories. (a) Identification. Pressure tubing and accessories are flexible or rigid devices intended to...

  4. 21 CFR 876.5900 - Ostomy pouch and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ostomy pouch and accessories. 876.5900 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5900 Ostomy pouch and accessories. (a) Identification. An ostomy pouch and accessories is a device that consists of a bag that is...

  5. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  6. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  7. Control rod selecting and driving device

    International Nuclear Information System (INIS)

    Isobe, Hideo.

    1981-01-01

    Purpose: To simultaneously drive a predetermined number of control rods in a predetermined mode by the control of addresses for predetermined number of control rods and read or write of driving codified data to and from the memory by way of a memory controller. Constitution: The system comprises a control rod information selection device for selecting predetermined control rods from a plurality of control rods disposed in a reactor and outputting information for driving them in a predetermined mode, a control rod information output device for codifying the information outputted from the above device and outputting the addresses to the predetermined control rods and driving mode coded data, and a driving device for driving said predetermined control rods in a predetermined mode in accordance with the codified data outputted from the above device, said control rod infromation output device comprising a memory device capable of storing a predetermined number of the codified data and a memory control device for storing the predetermined number of data into the above memory device at a predetermined timing while successively outputting the thus stored predetermined number of data at a predetermined timing. (Seki, T.)

  8. Building iPhone OS Accessories

    CERN Document Server

    Maskrey, Ken

    2010-01-01

    This book provides a serious, in-depth look at Apple's External Accessory Framework and the iPhone Accessories API. You'll learn how to create new, integrated solutions that combine iPhone apps with dedicated hardware. The iPhone OS Accessories API expands the opportunities for innovative iPhone developers, allowing you to control and monitor external devices, whether you've built them yourself or obtained them from a third party. What you'll learn * Develop accessories and apps for the iPhone and iPod touch. * Use Apple's External Accessory Framework to create hardware/software interaction. *

  9. Safety rod driving device

    International Nuclear Information System (INIS)

    Murakami, Kiyonobu; Kurosaki, Akira.

    1988-01-01

    Purpose: To rapidly insert safety rods for a criticality experiment device into a reactor core container to stop the criticality reaction thereby prevent reactivity accidents. Constitution: A cylinder device having a safety rod as a cylinder rod attached with a piston at one end is constituted. The piston is elevated by pressurized air and attracted and fixed by an electromagnet which is a stationary device disposed at the upper portion of the cylinder. If the current supply to the electromagnet is disconnected, the safety rod constituting the cylinder rod is fallen together with the piston to the lower portion of the cylinder. Since the cylinder rod driving device has neither electrical motor nor driving screw as in the conventional device, necessary space can be reduced and the weight is decreased. In addition, since the inside of the nuclear reactor can easily be shielded completely from the external atmosphere, leakage of radioactive materials can be prevented. (Horiuchi, T.)

  10. Testing device for control rod drives

    International Nuclear Information System (INIS)

    Hayakawa, Toshifumi.

    1992-01-01

    A testing device for control rod drives comprises a logic measuring means for measuring an output signal from a control rod drive logic generation circuit, a control means for judging the operation state of a control rod and a man machine interface means for outputting the result of the judgement. A driving instruction outputted from the control rod operation device is always monitored by the control means, and if the operation instruction is stopped, a testing signal is outputted to the control rod control device to simulate a control rod operation. In this case, the output signal of the control rod drive logic generation circuit is held in a control rod drive memory means and intaken into a logic analysis means for measurement and an abnormality is judged by the control means. The stopping of the control rod drive instruction is monitored and the operation abnormality of the control rod is judged, to mitigate the burden of an operator. Further, the operation of the control rod drive logic generation circuit can be confirmed even during a nuclear plant operation by holding the control rod drive instruction thereby enabling to improve maintenance efficiency. (N.H.)

  11. 21 CFR 870.4200 - Cardiopulmonary bypass accessory equipment.

    Science.gov (United States)

    2010-04-01

    ... Cardiopulmonary bypass accessory equipment. (a) Identification. Cardiopulmonary bypass accessory equipment is a... mounting bracket or system-priming equipment. (b) Classification. (1) Class I. The device is classified as class I if it does not involve an electrical connection to the patient. The device is exempt from the...

  12. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endoscopic electrocautery and accessories. 884... Surgical Devices § 884.4100 Endoscopic electrocautery and accessories. (a) Identification. An endoscopic electrocautery is a device used to perform female sterilization under endoscopic observation. It is designed to...

  13. 21 CFR 884.4120 - Gynecologic electrocautery and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gynecologic electrocautery and accessories. 884... Surgical Devices § 884.4120 Gynecologic electrocautery and accessories. (a) Identification. A gynecologic electrocautery is a device designed to destroy tissue with high temperatures by tissue contact with an...

  14. 21 CFR 876.5820 - Hemodialysis system and accessories.

    Science.gov (United States)

    2010-04-01

    ... system and accessories. (a) Identification. A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic... system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...

  15. 21 CFR 878.4700 - Surgical microscope and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical microscope and accessories. 878.4700 Section 878.4700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... microscope and accessories. (a) Identification. A surgical microscope and accessories is an AC-powered device...

  16. Gastroenterology-Urology Devices; Manual Gastroenterology-Urology Surgical Instruments and Accessories. Final rule; technical amendment.

    Science.gov (United States)

    2017-03-01

    The Food and Drug Administration (FDA) is amending the identification of manual gastroenterology-urology surgical instruments and accessories to reflect that the device does not include specialized surgical instrumentation for use with urogyencologic surgical mesh specifically intended for use as an aid in the insertion, placement, fixation, or anchoring of surgical mesh during urogynecologic procedures ("specialized surgical instrumentation for use with urogynecologic surgical mesh"). These amendments are being made to reflect changes made in the recently issued final reclassification order for specialized surgical instrumentation for use with urogynecologic surgical mesh.

  17. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproductive microscopes and microscope... Devices § 884.6190 Assisted reproductive microscopes and microscope accessories. (a) Identification. Assisted reproduction microscopes and microscope accessories (excluding microscope stage warmers, which are...

  18. 21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.

    Science.gov (United States)

    2010-04-01

    ... appliances and accessories. 888.3030 Section 888.3030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...

  19. Method for installing a control rod driving device in a reactor

    International Nuclear Information System (INIS)

    Sato, Haruo; Watanabe, Masatoshi.

    1975-01-01

    Object: To install a device using a wire rope, including individually moving up and down a control rod and a control rod driving device thereby enabling to install them within a low house and to reduce time required for installing operation. Structure: The control rod is temporarily attached to a support structure for the control rod driving device, the control rod driving device is suspended on a crane positioned upwardly of the support structure, a rope connected to the control rod driving device is connected to the control rod, a sagged portion of the rope is then wound about a rotary cylinder, the control rod is disconnected from its temporary attachment, and the wound rope is wound back while the rotary cylinder is rotated to move down the control rod. After the rope has been released from the rotary cylinder, the control rod driving device is moved down by the crane. (Kamimura, M.)

  20. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025... intended for medical purposes to support, protect, or aid in the use of a cast, orthosis (brace), or prosthesis. Examples of prosthetic and orthotic accessories include the following: A pelvic support band and...

  1. Control rod drive hydraulic device

    International Nuclear Information System (INIS)

    Takekawa, Toru.

    1994-01-01

    The device of the present invention can reliably prevent a possible erroneous withdrawal of control rod driving mechanism when the pressure of a coolant line is increased by isolation operation of hydraulic control units upon periodical inspection for a BWR type reactor. That is, a coolant line is connected to the downstream of a hydraulic supply device. The coolant line is connected to a hydraulic control unit. A coolant hydraulic detection device and a pressure setting device are disposed to the coolant line. A closing signal line and a returning signal line are disposed, which connect the hydraulic supply device and a flow rate control valve for the hydraulic setting device. In the device of the present invention, even if pressure of supplied coolants is elevated due to isolation of hydraulic control units, the elevation of the hydraulic pressure can be prevented. Accordingly, reliability upon periodical reactor inspection can be improved. Further, the facility is simplified and the installation to an existent facility is easy. (I.S.)

  2. Automatic exchange unit for control rod drive device

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To enable automatic reoperation and continuation without external power interruption remedy device at the time of recovering the interrupted power soruce during automatic positioning operation. Constitution: In case of an automatic exchange unit for a control rod drive device of the control type for setting the deviation between the positioning target position and the present position of the device to zero, the position data of the drive device of the positioning target value of the device is automatically read, and an interlock of operation inhibit is applied to a control system until the data reading is completed and automatic operation start or restart conditions are sequentially confirmed. After the confirmation, the interlock is released to start the automatic operation or reoperation. Accordingly, the automatic operation can be safely restarted and continued. (Yoshihara, H.)

  3. Measuring device for control rod driving time

    International Nuclear Information System (INIS)

    Tanaka, Kazuhiko; Hanabusa, Masatoshi.

    1993-01-01

    The present invention concerns a measuring device for control driving time having a function capable of measuring a selected control rod driving time and measuring an entire control rod driving time simultaneously. A calculation means and a store means for the selected rod control rod driving time, and a calculation means and a store means for the entire control rod driving time are disposed individually. Each of them measures the driving time and stores the data independent of each other based on a selected control rod insert ion signal and an entire control rod insertion signal. Even if insertion of selected and entire control rods overlaps, each of the control rod driving times can be measured reliably to provide an advantageous effect capable of more accurately conducting safety evaluation for the nuclear reactor based on the result of the measurement. (N.H.)

  4. 47 CFR 15.27 - Special accessories.

    Science.gov (United States)

    2010-10-01

    ... manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the... requiring special accessories is installed by or under the supervision of the party marketing the device, it...

  5. Control rod driving hydraulic device

    International Nuclear Information System (INIS)

    Sugano, Hiroshi.

    1993-01-01

    In a control rod driving hydraulic device for an improved BWR type reactor, a bypass pipeline is disposed being branched from a scram pipeline, and a control orifice and a throttle valve are interposed to the bypass pipeline for restricting pressure. Upon occurrence of scram, about 1/2 of water quantity flowing from an accumulator of a hydraulic control unit to the lower surface of a piston of control rod drives by way of a scram pipeline is controlled by the restricting orifice and the throttle valve, by which the water is discharged to a pump suction pipeline or other pipelines by way of the bypass pipeline. With such procedures, a function capable of simultaneously conducting scram for two control rod drives can be attained by one hydraulic control unit. Further, an excessive peak pressure generated by a water hammer phenomenon in the scram pipeline or the control rod drives upon occurrence of scram can be reduced. Deformation and failure due to the excessive peak pressure can be prevented, as well as vibrations and degradation of performance of relevant portions can be prevented. (N.H.)

  6. Creating a driving profile for older adults using GPS devices and naturalistic driving methodology.

    Science.gov (United States)

    Babulal, Ganesh M; Traub, Cindy M; Webb, Mollie; Stout, Sarah H; Addison, Aaron; Carr, David B; Ott, Brian R; Morris, John C; Roe, Catherine M

    2016-01-01

    Background/Objectives : Road tests and driving simulators are most commonly used in research studies and clinical evaluations of older drivers. Our objective was to describe the process and associated challenges in adapting an existing, commercial, off-the-shelf (COTS), in-vehicle device for naturalistic, longitudinal research to better understand daily driving behavior in older drivers. Design : The Azuga G2 Tracking Device TM was installed in each participant's vehicle, and we collected data over 5 months (speed, latitude/longitude) every 30-seconds when the vehicle was driven.  Setting : The Knight Alzheimer's Disease Research Center at Washington University School of Medicine. Participants : Five individuals enrolled in a larger, longitudinal study assessing preclinical Alzheimer disease and driving performance.  Participants were aged 65+ years and had normal cognition. Measurements :  Spatial components included Primary Location(s), Driving Areas, Mean Centers and Unique Destinations.  Temporal components included number of trips taken during different times of the day.  Behavioral components included number of hard braking, speeding and sudden acceleration events. Methods :  Individual 30-second observations, each comprising one breadcrumb, and trip-level data were collected and analyzed in R and ArcGIS.  Results : Primary locations were confirmed to be 100% accurate when compared to known addresses.  Based on the locations of the breadcrumbs, we were able to successfully identify frequently visited locations and general travel patterns.  Based on the reported time from the breadcrumbs, we could assess number of trips driven in daylight vs. night.  Data on additional events while driving allowed us to compute the number of adverse driving alerts over the course of the 5-month period. Conclusions : Compared to cameras and highly instrumented vehicle in other naturalistic studies, the compact COTS device was quickly installed and transmitted high

  7. 21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual gastroenterology-urology surgical... OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4730 Manual gastroenterology-urology surgical instrument and accessories. (a) Identification...

  8. Novel AC Servo Rotating and Linear Composite Driving Device for Plastic Forming Equipment

    Science.gov (United States)

    Liang, Jin-Tao; Zhao, Sheng-Dun; Li, Yong-Yi; Zhu, Mu-Zhi

    2017-07-01

    The existing plastic forming equipment are mostly driven by traditional AC motors with long transmission chains, low efficiency, large size, low precision and poor dynamic response are the common disadvantages. In order to realize high performance forming processes, the driving device should be improved, especially for complicated processing motions. Based on electric servo direct drive technology, a novel AC servo rotating and linear composite driving device is proposed, which features implementing both spindle rotation and feed motion without transmission, so that compact structure and precise control can be achieved. Flux switching topology is employed in the rotating drive component for strong robustness, and fractional slot is employed in the linear direct drive component for large force capability. Then the mechanical structure for compositing rotation and linear motion is designed. A device prototype is manufactured, machining of each component and the whole assembly are presented respectively. Commercial servo amplifiers are utilized to construct the control system of the proposed device. To validate the effectiveness of the proposed composite driving device, experimental study on the dynamic test benches are conducted. The results indicate that the output torque can attain to 420 N·m and the dynamic tracking errors are less than about 0.3 rad in the rotating drive. the dynamic tracking errors are less than about 1.6 mm in the linear feed. The proposed research provides a method to construct high efficiency and accuracy direct driving device in plastic forming equipment.

  9. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Science.gov (United States)

    2010-04-01

    ... Endoscopic electrosurgical unit and accessories. (a) Identification. An endoscopic electrosurgical unit and... device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self...

  10. Evaluation of semiconductor devices for Electric and Hybrid Vehicle (EHV) ac-drive applications, volume 1

    Science.gov (United States)

    Lee, F. C.; Chen, D. Y.; Jovanovic, M.; Hopkins, D. C.

    1985-01-01

    The results of evaluation of power semiconductor devices for electric hybrid vehicle ac drive applications are summarized. Three types of power devices are evaluated in the effort: high power bipolar or Darlington transistors, power MOSFETs, and asymmetric silicon control rectifiers (ASCR). The Bipolar transistors, including discrete device and Darlington devices, range from 100 A to 400 A and from 400 V to 900 V. These devices are currently used as key switching elements inverters for ac motor drive applications. Power MOSFETs, on the other hand, are much smaller in current rating. For the 400 V device, the current rating is limited to 25 A. For the main drive of an electric vehicle, device paralleling is normally needed to achieve practical power level. For other electric vehicle (EV) related applications such as battery charger circuit, however, MOSFET is advantageous to other devices because of drive circuit simplicity and high frequency capability. Asymmetrical SCR is basically a SCR device and needs commutation circuit for turn off. However, the device poses several advantages, i.e., low conduction drop and low cost.

  11. The risk of a safety-critical event associated with mobile device use in specific driving contexts.

    Science.gov (United States)

    Fitch, Gregory M; Hanowski, Richard J; Guo, Feng

    2015-01-01

    We explored drivers' mobile device use and its associated risk of a safety-critical event (SCE) in specific driving contexts. Our premise was that the SCE risk associated with mobile device use increases when the driving task becomes demanding. Data from naturalistic driving studies involving commercial motor vehicle drivers and light vehicle drivers were partitioned into subsets representative of specific driving contexts. The subsets were generated using data set attributes that included level of service and relation to junction. These attributes were selected based on exogenous factors known to alter driving task demands. The subsets were analyzed using a case-cohort approach, which was selected to complement previous investigations of mobile device SCE risk using naturalistic driving data. Both commercial motor vehicle and light vehicle drivers varied as to how much they conversed on a mobile device but did not vary their engagement in visual-manual subtasks. Furthermore, commercial motor vehicle drivers conversed less frequently as the driving task demands increased, whereas light vehicle drivers did not. The risk of an SCE associated with mobile device use was dependent on the subtask performed and the driving context. Only visual-manual subtasks were associated with an increased SCE risk, whereas conversing was associated with a decreased risk in some driving contexts. Drivers' engagement in mobile device subtasks varies by driving context. The SCE risk associated with mobile device use is dependent on the types of subtasks performed and the driving context. The findings of this exploratory study can be applied to the design of driver-vehicle interfaces that mitigate distraction by preventing visual-manual subtasks while driving.

  12. Hybrid vehicle powertrain system with power take-off driven vehicle accessory

    Science.gov (United States)

    Beaty, Kevin D.; Bockelmann, Thomas R.; Zou, Zhanijang; Hope, Mark E.; Kang, Xiaosong; Carpenter, Jeffrey L.

    2006-09-12

    A hybrid vehicle powertrain system includes a first prime mover, a first prime mover driven power transmission mechanism having a power take-off adapted to drive a vehicle accessory, and a second prime mover. The second prime mover is operable to drive the power transmission mechanism alone or in combination with the first prime mover to provide power to the power take-off through the power transmission mechanism. The invention further includes methods for operating a hybrid vehicle powertrain system.

  13. Device and method of cooling control rod drives

    International Nuclear Information System (INIS)

    Togashi, Hidetoshi; Mase, Noriaki; Matsumura, Yuichi.

    1985-01-01

    Purpose: To prevent the generation of local temperature rise depending on the reactor core position of the control rod drives and control the temperature to an averaged state in BWR type reactors. Method: Control rod drives having a large charging length of the housing in the pressure vessel involve such a factor that the temperature of the control rod drives is increased by the synergistic effect due to the radiation heat from the reactor core and to the unevenness of the cooling water flow rate, which renders an appropriate temperature control difficult for the reactor core position. A cooling water flow rate controlling device having a restriction mechanism is disposed on the cooling water feed path for each of the hydraulic control units of the control rod drives, so that flow rate to the control rod drives is increased at the center of the reactor core and decreased at the periphery thereof. As a result, average temperature state can be set, temperature increase due to cloggings can be prevented and the thermal effect can be eliminated to thereby improve the reliability. (Moriyama, K.)

  14. Do in-car devices affect experienced users' driving performance?

    Directory of Open Access Journals (Sweden)

    Allert S. Knapper

    2015-07-01

    Full Text Available Distracted driving is considered to be an important factor in road safety. To investigate how experienced user's driving behaviour is affected by in-vehicle technology, a fixed-base driving simulator was used. 20 participants drove twice in a rich simulated traffic environment while performing secondary, i.e. mobile phone and navigation system tasks. The results show that mean speed was lower in all experimental conditions, compared to baseline driving, while subjective effort increased. Lateral performance deteriorated only during visual–manual tasks, i.e. texting and destination entry, in which the participants glanced off the forward road for a substantial amount of time. Being experienced in manipulating in-car devices does not solve the problem of dual tasking when the primary task is a complex task like driving a moving vehicle. The results and discussion may shed some light on the current debate regarding phone use hazards.

  15. Electric drive systems including smoothing capacitor cooling devices and systems

    Energy Technology Data Exchange (ETDEWEB)

    Dede, Ercan Mehmet; Zhou, Feng

    2017-02-28

    An electric drive system includes a smoothing capacitor including at least one terminal, a bus bar electrically coupled to the at least one terminal, a thermoelectric device including a first side and a second side positioned opposite the first side, where the first side is thermally coupled to at least one of the at least one terminal and the bus bar, and a cooling element thermally coupled to the second side of the thermoelectric device, where the cooling element dissipates heat from the thermoelectric device.

  16. Decontamination of minimally invasive surgical endoscopes and accessories.

    Science.gov (United States)

    Ayliffe, G

    2000-08-01

    (1) Infections following invasive endoscopy are rare and are usually of endogenous origin. Nevertheless, infections do occur due to inadequate cleaning and disinfection and the use of contaminated rinse water and processing equipment. (2) Rigid and flexible operative endoscopes and accessories should be thoroughly cleaned and preferably sterilized using properly validated processes. (3) Heat tolerant operative endoscopes and accessories should be sterilized using a vacuum assisted steam sterilizer. Use autoclavable instrument trays or containers to protect equipment during transit and processing. Small bench top sterilizers without vacuum assisted air removal are unsuitable for packaged and lumened devices. (4) Heat sensitive rigid and flexible endoscopes and accessories should preferably be sterilized using ethylene oxide, low temperature steam and formaldehyde (rigid only) or gas plasma (if appropriate). (5) If there are insufficient instruments or time to sterilize invasive endoscopes, or if no suitable method is available locally, they may be disinfected by immersion in 2% glutaraldehyde or a suitable alternative. An immersion time of at least 10 min should be adopted for glutaraldehyde. This is sufficient to inactivate most vegetative bacteria and viruses including HIV and hepatitis B virus (HBV). Longer contact times of 20 min or more may be necessary if a mycobacterial infection is known or suspected. At least 3 h immersion in glutaraldehyde is required to kill spores. (6) Glutaraldehyde is irritant and sensitizing to the skin, eyes and respiratory tract. Measures must be taken to ensure glutaraldehyde is used in a safe manner, i.e., total containment and/or extraction of harmful vapour and the provision of suitable personal protective equipment, i.e., gloves, apron and eye protection if splashing could occur. Health surveillance of staff is recommended and should include a pre-employment enquiry regarding asthma, skin and mucosal sensitivity problems and

  17. Painful accessory navicular

    Energy Technology Data Exchange (ETDEWEB)

    Lawson, J.P.; Ogden, J.A.; Sella, E.; Barwick, K.W.

    1984-11-01

    The accessory navicular is usually considered a normal anatomic and roentgenographic variant. The term may refer to two distinct patterns. First, a sesamoid bone may be present within the posterior tibial tendon (Type 1); this is anatomically separate from the navicular. Second, an accessory ossification center may be medial to the navicular (Type 2). During postnatal development this is within a cartilaginous mass that is continuous with the cartilage of the navicular. At skeletal maturity the accessory center usually fuses with the navicular to form a curvilinear bone. The Type 2 pattern may be associated with a painful foot, particularly in the athletic adolescent, and should not be arbitrarily dismissed as a roentgenologic variant in the symptomatic patient. The clinical, radiologic, pathologic, and surgical findings in ten cases are reviewed. Roentgenographically the ossicle is triangular or heartshaped. sup(99m)Tc MDP imaging may be of value when the significance of the ossicle is uncertain. Even when the roentgenographic variant is bilateral, increased radionuclide activity occurs only on the symptomatic side. Histologic examination of surgically excised specimens reveals inflammatory chondro-osseous changes in the navicular-accessory navicular synchondrosis compatible with chronic trauma and stress fracture. Nonsurgical treatment with orthotics or cast immobilization produces variable results and resection of the accessory navicular may be the treatment of choice.

  18. Modeling and Simulation of Two Wheelchair Accessories for Pushing Doors.

    Science.gov (United States)

    Abdullah, Soran Jalal; Shaikh Mohammed, Javeed

    2017-03-27

    Independent mobility is vital to individuals of all ages, and wheelchairs have proven to be great personal mobility devices. The tasks of opening and navigating through a door are trivial for healthy people, while the same tasks could be difficult for some wheelchair users. A wide range of intelligent wheelchair controllers and systems, robotic arms, or manipulator attachments integrated with wheelchairs have been developed for various applications, including manipulating door knobs. Unfortunately, the intelligent wheelchairs and robotic attachments are not widely available as commercial products. Therefore, the current manuscript presents the modeling and simulation of a novel but simple technology in the form of a passive wheelchair accessory (straight, arm-like with a single wheel, and arc-shaped with multiple wheels) for pushing doors open from a wheelchair. From the simulations using different wheel shapes and sizes, it was found that the arc-shaped accessory could push open the doors faster and with almost half the required force as compared to the arm-like accessory. Also, smaller spherical wheels were found to be best in terms of reaction forces on the wheels. Prototypes based on the arc-shaped accessory design will be manufactured and evaluated for pushing doors open and dodging or gliding other obstacles.

  19. Mobile device use while driving--United States and seven European countries, 2011.

    Science.gov (United States)

    2013-03-15

    Road traffic crashes are a global public health problem, contributing to an estimated 1.3 million deaths annually. Known risk factors for road traffic crashes and related injuries and deaths include speed, alcohol, nonuse of restraints, and nonuse of helmets. More recently, driver distraction has become an emerging concern. To assess the prevalence of mobile device use while driving in Belgium, France, Germany, the Netherlands, Portugal, Spain, the United Kingdom (UK), and the United States, CDC analyzed data from the 2011 EuroPNStyles and HealthStyles surveys. Prevalence estimates for self-reported talking on a cell phone while driving and reading or sending text or e-mail messages while driving were calculated. This report describes the results of that analysis, which indicated that, among drivers ages 18-64 years, the prevalence of talking on a cell phone while driving at least once in the past 30 days ranged from 21% in the UK to 69% in the United States, and the prevalence of drivers who had read or sent text or e-mail messages while driving at least once in the past 30 days ranged from 15% in Spain to 31% in Portugal and the United States. Lessons learned from successful road safety efforts aimed at reducing other risky driving behaviors, such as seat belt nonuse and alcohol-impaired driving, could be helpful to the United States and other countries in addressing this issue. Strategies such as legislation combined with high-visibility enforcement and public education campaigns deserve further research to determine their effectiveness in reducing mobile device use while driving. Additionally, the role of emerging vehicle and mobile communication technologies in reducing distracted driving-related crashes should be explored.

  20. An optoelectronic integrated device including a laser and its driving circuit

    Energy Technology Data Exchange (ETDEWEB)

    Matsueda, H.; Nakano, H.; Tanaka, T.P.

    1984-10-01

    A monolithic optoelectronic integrated circuit (OEIC) including a laser diode, photomonitor and driving and detecting circuits has been fabricated on a semi-insulating GaAs substrate. The OEIC has a horizontal integrating structure which is suitable for realising high-density multifunctional devices. The fabricating process and the static and dynamic characteristics of the optical and electronic elements are described. The preliminary results of the co-operative operation of the laser and its driving circuit are also presented.

  1. Small Engine & Accessory Test Area

    Data.gov (United States)

    Federal Laboratory Consortium — The Small Engine and Accessories Test Area (SEATA) facilitates testaircraft starting and auxiliary power systems, small engines and accessories. The SEATA consists...

  2. Electromagnetic analysis of locking device for SMART control element drive mechanism

    International Nuclear Information System (INIS)

    Heo, H.; Kim, J. I.; Kim, J. H.; Kim, Y. W.; Park, J. S.

    1998-01-01

    A numerical electromagnetic analysis was performed for the control rod locking device which is installed in the control element drive mechanism of integral reactor, SMART. A plunger model for the electromagnetic analysis of the locking device was developed and theoretical bases for the model were established. Design parameters related to plunger pushing force were identified, and the optimum design point was determined by analyzing the trend of the plunger pushing force with finite element method

  3. Control device for handling device of control rod drive

    International Nuclear Information System (INIS)

    Sasaki, Toshiya

    1998-01-01

    A predetermined aimed portion of control rod drives disposed in a pedestal is photographed, and image data and camera data including the position of the camera are outputted. Edge cut out processing image data are formed based on the outputted image data, and aimed image data and aimed camera data obtained when previously positioning the handling device precisely to a predetermined aimed position are stored. The aimed image data are taken out from the aimed image data file to prepare computer graphic image data, and there is disposed an image superposing processing portion for comparing images based on the computer graphic image data and images based on the image data for edge cut out processing, as well as comparing the aimed camera data and the camera data, and displaying each of them to an image display portion. (I.S.)

  4. The painful accessory navicular

    International Nuclear Information System (INIS)

    Lawson, J.P.; Ogden, J.A.; Sella, E.; Barwick, K.W.

    1984-01-01

    The accessory navicular is usually considered a normal anatomic and roentgenographic variant. The term may refer to two distinct patterns. First, a sesamoid bone may be present within the posterior tibial tendon (Type 1); this is anatomically separate from the navicular. Second, an accessory ossification center may be medial to the navicular (Type 2). During postnatal development this is within a cartilaginous mass that is continuous with the cartilage of the navicular. At skeletal maturity the accessory center usually fuses with the navicular to form a curvilinear bone. The Type 2 pattern may be associated with a painful foot, particularly in the athletic adolescent, and should not be arbitrarily dismissed as a roentgenologic variant in the symptomatic patient. The clinical, radiologic, pathologic, and surgical findings in ten cases are reviewed. Roentgenographically the ossicle is triangular or heartshaped. sup(99m)Tc MDP imaging may be of value when the significance of the ossicle is uncertain. Even when the roentgenographic variant is bilateral, increased radionuclide activity occurs only on the symptomatic side. Histologic examination of surgically excised specimens reveals inflammatory chondro-osseous changes in the navicular-accessory navicular synchondrosis compatible with chronic trauma and stress fracture. Nonsurgical treatment with orthotics or cast immobilization produces variable results and resection of the accessory navicular may be the treatment of choice. (orig.)

  5. A long slanted transseptal accessory pathway

    Directory of Open Access Journals (Sweden)

    Hui-Min Wang

    2011-05-01

    Full Text Available A 63-year-old male with Wolff-Parkinson-White syndrome was admitted for ablation of accessory pathway. Intracardiac electrogram revealed a left-side accessory pathway during tachycardia, which was successfully ablated from the right posterior tricuspid annulus because of a long slanted transseptal accessory pathway (2.2 cm.

  6. Leaked water detection device for control rod drive and BWR type reactor

    International Nuclear Information System (INIS)

    Takahashi, Ken.

    1995-01-01

    The device of the present invention can specify a control rod drive causing great amount of water leakage among a large number of control rod drives. Namely, water leaked from the control rod drives is introduced to each of leaked water pipelines. Further, it is introduced from the leaked water pipelines to flow glasses at which leaked water can visually be recognized individually, and then discharged through a drain pipeline. With such procedures, the amount of leaked water from the leaked water pipelines can visually be recognized at the flow glasses. As a result, the control rod drives which cause a great amount of leakage can be specified among large number of control rod drives. Accordingly, an accurate inspection schedule for a shaft-sealing portion of the control rod drives can be formed. The shaft-sealing portion degradated in the sealing property can reliably be inspected and repaired. Purge water can be ensured to improve reliability of the operation of equipments. (I.S.)

  7. Control rod driving mechanism of reactor, control device and operation method therefor

    International Nuclear Information System (INIS)

    Ariyoshi, Masahiko; Matsumoto, Fujio; Matsumoto, Koji; Kinugasa, Kunihiko; Nara, Yoshihiko; Otama, Kiyomaro; Mikami, Takao

    1998-01-01

    The present invention provides a device for and a method of directly driving control rods of an FBR type reactor linearly by a cylinder type linear motor while having a driving shaft as an electric conductor. Namely, a linear induction motor drives a driving shaft connected with a control rod and vertically moving the control rod by electromagnetic force as an electric conductor. The position of the control rod is detected by a position detector. The driving shaft is hung by a wire by way of an electromagnet which is attachably/detachably held. With such a constitution, the driving shaft connected with the control rod can be vertically moved linearly, stopped or kept. Since they can be driven smoothly at a wide range speed, the responsibility and reliability of the reactor operation can be improved. In addition, since responsibility of the control rod operation is high, scram can be conducted by the linear motor. Since the driving mechanism can be simplified, maintenance and inspection operation can be mitigated. (I.S.)

  8. Electromagnetic analysis of locking device for SMART control element drive mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Hyung; Kim, J. I.; Kim, J. H. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-09-01

    A numerical electromagnetic analysis was performed for the control rod locking device which is installed in the control element drive mechanism of integral reactor, SMART. A plunger model for the electromagnetic analysis of the locking device was developed and theoretical bases for the model were established. Design parameters related to plunger pushing force were identified, and the optimum design point was determined by analysing the trend of the plunger pushing force with finite element method. 8 refs., 22 figs., 2 tabs. (Author)

  9. Creating a driving profile for older adults using GPS devices and naturalistic driving methodology [version 2; referees: 2 approved, 1 approved with reservations

    Directory of Open Access Journals (Sweden)

    Ganesh M. Babulal

    2016-12-01

    Full Text Available Background/Objectives: Road tests and driving simulators are most commonly used in research studies and clinical evaluations of older drivers. Our objective was to describe the process and associated challenges in adapting an existing, commercial, off-the-shelf (COTS, in-vehicle device for naturalistic, longitudinal research to better understand daily driving behavior in older drivers. Design: The Azuga G2 Tracking DeviceTM was installed in each participant’s vehicle, and we collected data over 5 months (speed, latitude/longitude every 30-seconds when the vehicle was driven.  Setting: The Knight Alzheimer’s Disease Research Center at Washington University School of Medicine. Participants: Five individuals enrolled in a larger, longitudinal study assessing preclinical Alzheimer disease and driving performance.  Participants were aged 65+ years and had normal cognition. Measurements:  Spatial components included Primary Location(s, Driving Areas, Mean Centers and Unique Destinations.  Temporal components included number of trips taken during different times of the day.  Behavioral components included number of hard braking, speeding and sudden acceleration events. Methods:  Individual 30-second observations, each comprising one breadcrumb, and trip-level data were collected and analyzed in R and ArcGIS.  Results: Primary locations were confirmed to be 100% accurate when compared to known addresses.  Based on the locations of the breadcrumbs, we were able to successfully identify frequently visited locations and general travel patterns.  Based on the reported time from the breadcrumbs, we could assess number of trips driven in daylight vs. night.  Data on additional events while driving allowed us to compute the number of adverse driving alerts over the course of the 5-month period. Conclusions: Compared to cameras and highly instrumented vehicle in other naturalistic studies, the compact COTS device was quickly installed and

  10. Coupling device of the control rod and of the drive mechanism

    International Nuclear Information System (INIS)

    Savary, F.

    1986-01-01

    The invention proposes a coupling device removable in which the connection between the upper head of the control rod and the drive mechanism is a real rigid fixing, in the mechanical sense of the term, suppressing longitudinal play and allowing to restrict the momenta occurring when locating the control rods [fr

  11. Influence of Telecommunication Modality, Internet Transmission Quality, and Accessories on Speech Perception in Cochlear Implant Users

    Science.gov (United States)

    Koller, Roger; Guignard, Jérémie; Caversaccio, Marco; Kompis, Martin; Senn, Pascal

    2017-01-01

    Background Telecommunication is limited or even impossible for more than one-thirds of all cochlear implant (CI) users. Objective We sought therefore to study the impact of voice quality on speech perception with voice over Internet protocol (VoIP) under real and adverse network conditions. Methods Telephone speech perception was assessed in 19 CI users (15-69 years, average 42 years), using the German HSM (Hochmair-Schulz-Moser) sentence test comparing Skype and conventional telephone (public switched telephone networks, PSTN) transmission using a personal computer (PC) and a digital enhanced cordless telecommunications (DECT) telephone dual device. Five different Internet transmission quality modes and four accessories (PC speakers, headphones, 3.5 mm jack audio cable, and induction loop) were compared. As a secondary outcome, the subjective perceived voice quality was assessed using the mean opinion score (MOS). Results Speech telephone perception was significantly better (median 91.6%, P 15%) were not superior to conventional telephony. In addition, there were no significant differences between the tested accessories (P>.05) using a PC. Coupling a Skype DECT phone device with an audio cable to the CI, however, resulted in higher speech perception (median 65%) and subjective MOS scores (3.2) than using PSTN (median 7.5%, P<.001). Conclusions Skype calls significantly improve speech perception for CI users compared with conventional telephony under real network conditions. Listening accessories do not further improve listening experience. Current Skype DECT telephone devices do not fully offer technical advantages in voice quality. PMID:28438727

  12. Biliary self-expandable metallic stent using single balloon enteroscopy assisted ERCP: overcoming limitations of current accessories

    Directory of Open Access Journals (Sweden)

    Rolando Pinho

    2013-10-01

    Full Text Available Device assisted enteroscopy (DAE techniques have been recently developed for the diagnosis and treatment of small bowel diseases. These techniques can also be used to perform endoscopic retrograde cholangiopancreatography (ERCP in patients with surgically altered anatomies. The main difficulties with DAE-ERCP are related to type of surgery, to the different dimensions and lack of frontal view of the enteroscope and to the resulting limitations with the use of standard accessories, resulting in the need of dedicated accessory devices. Although most ERCP techniques have been successfully performed with DAE-ERCP, biliary self-expandable metallic stents (SEMS have not yet been used, as dedicated biliary SEMS for the enteroscope are lacking. The authors present a case report showing a new method to place standard biliary trough-the-scope SEMS with DAE-ERCP, using a different technique of stent deployment.

  13. MR imaging of accessory muscles of the ankle

    International Nuclear Information System (INIS)

    Mondello, Eduardo; Nazar, Miguel E.; Martin, Eduardo

    2001-01-01

    Purpose: The purpose of this work is to describe the normal anatomy and the characteristics in MRI of the accessory muscles of the posterior ankle: the accessory soleus, accessory flexor digitorum longus, peroneus quartus, tibiocalcaneus internus and peroneocalcaneus internus. Material and methods: There were evaluated 280 symptomatic patients between 18 and 40 years old (85 % males). MR was performed in High Field Magnetic Resonance Units (1.5 T y 1.0 T) and multiplanar sequences. Results: We found 2 peroneus quartus (0.7%), 2 accessory soleus muscles (0.7%), 3 accessory flexor digitorum longus (1.07%) and 1 peroneocalcaneus internus (0.35%). Conclusion: The knowledge of the accessory muscles of the posterior ankle allow to explain different painful pathologies with instability or tendinous tears, which are difficult to diagnose if the muscle are not adequately recognized. (author)

  14. Accessory hepatic vein: MR imaging

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Rho, Tack Soo; Cha, Sang Hoon; Park, Cheol Min; Cha, In Ho

    1995-01-01

    To evaluate the MR appearance of the accessory hepatic veins. The study included 87 consecutive patients for whom abdominal MR images were obtained. The subjects who had liver lesion or hepatic vascular abnormalities were excluded. Couinaud classified accessory hepatic veins into inferior and middle right hepatic veins. Our major interests were evaluation of the incidence, morphology, and location of the accessory hepatic vein. Inferior right hepatic vein was demonstrated in 43 out of 87 patients (49%). The morphology was linear in 35 patients (80.5%), and V-shaped in 8 patients (19.5%). In 40 patients (93%), the inferior right hepatic vein was located in the posteroinferior aspect of the right lobe. Middle right hepatic vein was demonstrated in 7 out of 87 patients (8%). All were single linear in morphology, combined with the inferior right hepatic vein, and located between the right hepatic vein and inferior right hepatic vein. The accessory hepatic vein was demonstrated in 49% among the Korean adult population, and was located in posteroinferior portion of the liver, in 93%

  15. Creating a driving profile for older adults using GPS devices and naturalistic driving methodology [version 1; referees: 2 approved, 1 approved with reservations

    Directory of Open Access Journals (Sweden)

    Ganesh M. Babulal

    2016-09-01

    Full Text Available Background/Objectives: Road tests and driving simulators are most commonly used in research studies and clinical evaluations of older drivers. We adapted an existing, commercial, off-the-shelf, in-vehicle device for naturalistic, longitudinal research to better understand daily driving behavior in older drivers. Design: The Azuga G2 Tracking DeviceTM was installed in each participant’s vehicle, and we collected data over 5 months (speed, latitude/longitude every 30-seconds when the vehicle was driven.  Setting: The Knight Alzheimer’s Disease Research Center at Washington University School of Medicine. Participants: Five individuals enrolled in a larger, longitudinal study assessing preclinical Alzheimer disease and driving performance.  Participants were aged 65+ years and had normal cognition. Measurements:  Spatial components included Primary Location(s, Driving Areas, Mean Centers and Unique Destinations.  Temporal components included number of trips taken during different times of the day.  Behavioral components included number of hard braking, speeding and sudden acceleration events. Methods:  Individual 30-second observations, each comprising one breadcrumb, and trip-level data were collected and analyzed in R and ArcGIS.  Results: Primary locations were confirmed to be 100% accurate when compared to known addresses.  Based on the locations of the breadcrumbs, we were able to successfully identify frequently visited locations and general travel patterns.  Based on the reported time from the breadcrumbs, we could assess number of trips driven in daylight vs. night.  Data on additional events while driving allowed us to compute the number of adverse driving alerts over the course of the 5-month period. Conclusions: This pilot study indicated that Driving Profiles for older adults can be created and compared month-to-month or year-to-year, allowing researchers to identify changes in driving patterns that are unavailable in

  16. Isolated spinal accessory neuropathy and intracisternal schwannomas of the spinal accessory nerve

    Directory of Open Access Journals (Sweden)

    Abdullah M. Al-Ajmi

    2015-03-01

    Full Text Available We report a 40-year-old female patient presenting with isolated left spinal accessory neuropathy that developed insidiously over 6 years. She complained of ill-defined deep neck and shoulder pain. On examination, prominent sternocleidomastoid and trapezoid muscle weakness and atrophy, shoulder instability, and lateral scapular winging were observed. MRI identified a small mass of the cisternal portion of the spinal accessory nerve. Its appearance was typical of schwannoma. Surgical treatment was not offered because of the small tumor size, lack of mass effect and the questionable functional recovery in the presence of muscular atrophy.

  17. Control rod driving hydraulic pressure device

    International Nuclear Information System (INIS)

    Ogawa, Masahide.

    1993-01-01

    The present invention concerns a control rod driving hydraulic device of a BWR type reactor, and provides an improvement for a means for supplying mechanical seal flashing water of a pump. That is, a mechanical seal flashing pipeline is branched at the downstream of a pressure-reducing orifice and connected to a minimum flow pipeline. With such a constitution, the minimum flow pipeline is connected to a minimum flow pipeline of an auxiliary pump at the downstream of the pressure-reducing orifice and returned to a suction pipeline of the pump. Pressure at the downstream of the pressure-reducing orifice is set, in the orifice, to a pressure required for mechanical seal flashing. Accordingly, the mechanical seal flashing pipeline is connected and a part of minimum flow rate is utilized, thereby enabling to cool mechanical seals. As a result, flow rate of the mechanical flashing water which has been flown out can be saved. The exhaustion amount from the pump can be reduced, to decrease the shaft power and reduce the capacity of the motor. (I.S.)

  18. 21 CFR 864.3400 - Device for sealing microsections.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device for sealing microsections. 864.3400 Section 864.3400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864...

  19. [Excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for treatment of flatfoot related with accessory navicular].

    Science.gov (United States)

    Cao, Honghui; Tang, Kanglai; Deng, Yinshuan; Tan, Xiaokang; Zhou, Binghua; Tao, Xu; Chen, Lei; Chen, Qianbo

    2012-06-01

    To analyze the excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for the treatment of flatfoot related with accessory navicular and to evaluate its effectiveness. Between May 2006 and June 2011, 33 patients (40 feet) with flatfoot related with accessory navicular were treated. There were 14 males (17 feet) and 19 females (23 feet) with an average age of 30.1 years (range, 16-56 years). All patients had bilateral accessory navicular; 26 had unilateral flatfoot and 7 had bilateral flatfeet. The disease duration ranged from 7 months to 9 years (median, 24 months). The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-midfoot score was 47.9 +/- 7.3. The X-ray films showed type II accessory navicular, the arch height loss, and heel valgus in all patients. All of them received excision of accessory navicular and reconstruction of posterior tibial tendon insertion on navicular with anchor. All patients got primary wound healing without any complication. Thirty patients (36 feet) were followed up 6-54 months with an average of 23 months. All patients achieved complete pain relief at 6 months after surgery and had good appearance of the feet. The AOFAS ankle-midfoot score was 90.4 +/- 2.0 at last follow-up, showing significant difference when compared with preoperative score (t=29.73, P=0.00). X-ray films showed that no screw loosening or breakage was observed. There were significant differences in the arch height, calcaneus inclination angle, talocalcaneal angle, and talar-first metatarsal angle between pre-operation and last follow-up (P < 0.01). The excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular is a good choice for the treatment of flatfoot related with accessory navicular, with correction of deformity, excellent effectiveness, and less complications.

  20. 19 CFR 10.537 - Accessories, spare parts, or tools.

    Science.gov (United States)

    2010-04-01

    ... parts, or tools will be taken into account as originating or non-originating materials, as the case may... 19 Customs Duties 1 2010-04-01 2010-04-01 false Accessories, spare parts, or tools. 10.537 Section... Free Trade Agreement Rules of Origin § 10.537 Accessories, spare parts, or tools. Accessories, spare...

  1. Recycling temperature elevation device and temperature control method for control rod driving system

    International Nuclear Information System (INIS)

    Okamura, Hajime.

    1996-01-01

    The present invention concerns a device for and a method of controlling a recycling temperature control device for control rod drives (CRD) of a nuclear power plant, which can prevent occurrence of cavitation and keep the amount of cooling water to be transferred to a water source transfer pipeline thereby improving maintenanciability, operationability and reliability. Namely, a supply pipeline supplies cooling water required for the control rod drives from a water source. A CRD pump elevates the pressure of the cooling water. A recycling pipeline is branched from the downstream of the CRD pump of the supply pipeline and connected to the supply pipeline at the upstream of the CRD pump. A first pressure element and a restricting valve disposed at the upstream thereof are connected to the upstream of the CRD pump and the water source transfer pipeline. The water source transfer pipeline is branched from the recycling pipeline and connected to the water source. A second pressure element is disposed to a recycling pipeline at the downstream of the branched point from the water source transfer pipeline. (I.S.)

  2. Control rod drives

    International Nuclear Information System (INIS)

    Hayakawa, Hiroyasu.

    1979-01-01

    Purpose: To enable rapid control in a simple circuit by providing a motor control device having an electric capacity capable of simultaneously driving all of the control rods rapidly only in the inserting direction as well as a motor controlling device capable of fine control for the insertion and extraction at usual operation. Constitution: The control rod drives comprise a first motor control device capable of finely controlling the control rods both in inserting and extracting directions, a second motor control device capable of rapidly driving the control rods only in the inserting direction, and a first motor switching circuit and a second motor switching circuit switched by switches. Upon issue of a rapid insertion instruction for the control rods, the second motor switching circuit is closed by the switch and the second motor control circuit and driving motors are connected. Thus, each of the control rod driving motors is driven at a high speed in the inserting direction to rapidly insert all of the control rods. (Yoshino, Y.)

  3. Giant Accessory Right-Sided Suprarenal Spleen in Thalassaemia

    Directory of Open Access Journals (Sweden)

    A. Arra

    2013-01-01

    Full Text Available An accessory spleen is defined as ectopic splenic tissue that develops due to failure of fusion of cells during embryonic development as they migrate from the midline to the left upper quadrant. While benign, complications may arise which include trauma, torsion, or infarction of the ectopic tissue. Additionally, patients who have had a splenectomy secondary to treatment for previous pathology such as a haematological malignancy or idiopathic thrombocytopenia purpura may experience persistent symptoms due to the accessory splenic tissue. The presence of an accessory spleen is therefore of significant diagnostic and therapeutic importance. To the best of the authors' knowledge, this case is the second and largest reported case of a giant right suprarenal accessory spleen and highlights the difficulty in differentiation of these masses from malignant adrenal tumours.

  4. Control rod driving hydraulic pressure device

    International Nuclear Information System (INIS)

    Ishida, Kazuo.

    1990-01-01

    Discharged water after actuating control rod drives in a BWR type reactor is once discharged to a discharging header, then returned to a master control unit and, subsequently, discharged to a reactor by way of a cooling water header. The radioactive level in the discharging header and the master control unit is increased by the reactor water to increase the operator's exposure. In view of the above, a riser is disposed for connecting a hydraulic pressure control unit incorporating a directional control valve and the cooling water head. When a certain control rod is inserted, the pressurized driving water is supplied through a hydraulic pressure control unit to the control rod drives. The discharged water from the control rod drives is entered by way of the hydraulic pressure control unit into the cooling water header and then returned to the reactor by way of other hydraulic pressure control unit and the control rod drives. Thus, the reactor water is no more recycled to the master control unit to reduce the radioactive exposure. (N.H.)

  5. Low driving voltage simplified tandem organic light-emitting devices by using exciplex-forming hosts

    Science.gov (United States)

    Zhou, Dong-Ying; Cui, Lin-Song; Zhang, Ying-Jie; Liao, Liang-Sheng; Aziz, Hany

    2014-10-01

    Tandem organic light-emitting devices (OLEDs), i.e., OLEDs containing multiple electroluminescence (EL) units that are vertically stacked, are attracting significant interest because of their ability to realize high current efficiency and long operational lifetime. However, stacking multiple EL units in tandem OLEDs increases driving voltage and complicates fabrication process relative to their standard single unit counterparts. In this paper, we demonstrate low driving voltage tandem OLEDs via utilizing exciplex-forming hosts in the EL units instead of conventional host materials. The use of exciplex-forming hosts reduces the charge injection barriers and the trapping of charges on guest molecules, resulting in the lower driving voltage. The use of exciplex-forming hosts also allows using fewer layers, hence simpler EL configuration which is beneficial for reducing the fabrication complexity of tandem OLEDs.

  6. A System of Driving Fatigue Detection Based on Machine Vision and Its Application on Smart Device

    Directory of Open Access Journals (Sweden)

    Wanzeng Kong

    2015-01-01

    Full Text Available Driving fatigue is one of the most important factors in traffic accidents. In this paper, we proposed an improved strategy and practical system to detect driving fatigue based on machine vision and Adaboost algorithm. Kinds of face and eye classifiers are well trained by Adaboost algorithm in advance. The proposed strategy firstly detects face efficiently by classifiers of front face and deflected face. Then, candidate region of eye is determined according to geometric distribution of facial organs. Finally, trained classifiers of open eyes and closed eyes are used to detect eyes in the candidate region quickly and accurately. The indexes which consist of PERCLOS and duration of closed-state are extracted in video frames real time. Moreover, the system is transplanted into smart device, that is, smartphone or tablet, due to its own camera and powerful calculation performance. Practical tests demonstrated that the proposed system can detect driver fatigue with real time and high accuracy. As the system has been planted into portable smart device, it could be widely used for driving fatigue detection in daily life.

  7. Accessory stimulus modulates executive function during stepping task.

    Science.gov (United States)

    Watanabe, Tatsunori; Koyama, Soichiro; Tanabe, Shigeo; Nojima, Ippei

    2015-07-01

    When multiple sensory modalities are simultaneously presented, reaction time can be reduced while interference enlarges. The purpose of this research was to examine the effects of task-irrelevant acoustic accessory stimuli simultaneously presented with visual imperative stimuli on executive function during stepping. Executive functions were assessed by analyzing temporal events and errors in the initial weight transfer of the postural responses prior to a step (anticipatory postural adjustment errors). Eleven healthy young adults stepped forward in response to a visual stimulus. We applied a choice reaction time task and the Simon task, which consisted of congruent and incongruent conditions. Accessory stimuli were randomly presented with the visual stimuli. Compared with trials without accessory stimuli, the anticipatory postural adjustment error rates were higher in trials with accessory stimuli in the incongruent condition and the reaction times were shorter in trials with accessory stimuli in all the task conditions. Analyses after division of trials according to whether anticipatory postural adjustment error occurred or not revealed that the reaction times of trials with anticipatory postural adjustment errors were reduced more than those of trials without anticipatory postural adjustment errors in the incongruent condition. These results suggest that accessory stimuli modulate the initial motor programming of stepping by lowering decision threshold and exclusively under spatial incompatibility facilitate automatic response activation. The present findings advance the knowledge of intersensory judgment processes during stepping and may aid in the development of intervention and evaluation tools for individuals at risk of falls. Copyright © 2015 the American Physiological Society.

  8. Development of a compact wearable pneumatic drive unit for a ventricular assist device.

    Science.gov (United States)

    Homma, Akihiko; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Akagawa, Eiki; Lee, Hwansung; Nishinaka, Tomohiro; Takewa, Yoshiaki; Mizuno, Toshihide; Tsukiya, Tomonori; Kakuta, Yukihide; Katagiri, Nobumasa; Shimosaki, Isao; Hamada, Shigeru; Mukaibayashi, Hiroshi; Iwaoka, Wataru

    2008-01-01

    The purpose of this study was to develop a compact wearable pneumatic drive unit for a ventricular assist device (VAD). This newly developed drive unit, 20 x 8.5 x 20 cm in size and weighing approximately 1.8 kg, consists of a brushless DC motor, noncircular gears, a crankshaft, a cylinder-piston, and air pressure regulation valves. The driving air pressure is generated by the reciprocating motion of the piston and is controlled by the air pressure regulation valves. The systolic ratio is determined by the noncircular gears, and so is fixed for a given configuration. As a result of an overflow-type mock circulation test, a drive unit with a 44% systolic ratio connected to a Toyobo VAD blood pump with a 70-ml stroke volume achieved a pump output of more than 7 l/min at 100 bpm against a 120 mmHg afterload. Long-term animal tests were also performed using drive units with systolic ratios of 45% and 53% in two Holstein calves weighing 62 kg and 74 kg; the tests were terminated on days 30 and 39, respectively, without any malfunction. The mean aortic pressure, bypass flow, and power consumption for the first calf were maintained at 90 x 13 mmHg, 3.9 x 0.9 l/min, and 12 x 1 W, and those for the second calf were maintained at 88 x 13 mmHg, 5.0 x 0.5 l/min, and 16 x 2 W, respectively. These results indicate that the newly developed drive unit may be used as a wearable pneumatic drive unit for the Toyobo VAD blood pump.

  9. Incidence and characteristics of mandibular accessory canals: A radiographic investigation.

    Science.gov (United States)

    Borgonovo, Andrea Enrico; Taschieri, Silvio; Vavassori, Virna; Re, Dino; Francetti, Luca; Corbella, Stefano

    2017-11-01

    The aim of the present study was to explore, through tridimensional reconstructions of cone-beam computed tomography (CBCT) scans, the presence and the characteristics of mandibular accessory canals. For each included participant, the presence of accessory canals was recorded. The diameter of the canal, as well as the distance between the canal walls and the walls of the mandibular bone (lingual, buccal, cranial and caudal), were measured and recorded. Mandibular accessory canals could be found in 8.8% of participants. Retromolar canals were the most frequently found accessory mandibular canals. Accessory mandibular canals were found in a relatively high number of participants through the examination of CBCT scans and tridimensional reconstruction. The presence of such structures should be considered cautiously when planning and performing surgical interventions in mandibular area. © 2017 John Wiley & Sons Australia, Ltd.

  10. Accessory spleen presenting as acute abdomen: A case report and operative management

    Directory of Open Access Journals (Sweden)

    A. Landmann

    2016-09-01

    Full Text Available Accessory spleens are found in 10–30% of patients and are asymptomatic. Rarely, torsion of an accessory spleen can cause abdominal pain and acute abdomen. We present the case of an 8-year-old girl who arrives to the emergency room with left upper quadrant abdominal pain. CT scan revealed a non-enhancing soft tissue mass and multiple small splenules. Laparoscopy revealed a torsed accessory spleen and malrotation. Accessory spleen is a common congenital anomaly that is frequently asymptomatic. Rarely, an accessory spleen may become torsed around its vascular pedicle resulting in severe abdominal pain. Treatment is surgical resection. Torsion of accessory splenic tissue is a rare cause of acute abdomen in pediatric patients.

  11. Monitoring driver fatigue using a single-channel electroencephalographic device: A validation study by gaze-based, driving performance, and subjective data.

    Science.gov (United States)

    Morales, José M; Díaz-Piedra, Carolina; Rieiro, Héctor; Roca-González, Joaquín; Romero, Samuel; Catena, Andrés; Fuentes, Luis J; Di Stasi, Leandro L

    2017-12-01

    Driver fatigue can impair performance as much as alcohol does. It is the most important road safety concern, causing thousands of accidents and fatalities every year. Thanks to technological developments, wearable, single-channel EEG devices are now getting considerable attention as fatigue monitors, as they could help drivers to assess their own levels of fatigue and, therefore, prevent the deterioration of performance. However, the few studies that have used single-channel EEG devices to investigate the physiological effects of driver fatigue have had inconsistent results, and the question of whether we can monitor driver fatigue reliably with these EEG devices remains open. Here, we assessed the validity of a single-channel EEG device (TGAM-based chip) to monitor changes in mental state (from alertness to fatigue). Fifteen drivers performed a 2-h simulated driving task while we recorded, simultaneously, their prefrontal brain activity and saccadic velocity. We used saccadic velocity as the reference index of fatigue. We also collected subjective ratings of alertness and fatigue, as well as driving performance. We found that the power spectra of the delta EEG band showed an inverted U-shaped quadratic trend (EEG power spectra increased for the first hour and half, and decreased during the last thirty minutes), while the power spectra of the beta band linearly increased as the driving session progressed. Coherently, saccadic velocity linearly decreased and speeding time increased, suggesting a clear effect of fatigue. Subjective data corroborated these conclusions. Overall, our results suggest that the TGAM-based chip EEG device is able to detect changes in mental state while performing a complex and dynamic everyday task as driving. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Value of transoperative scintigraphy in the detection of accessory spleens

    International Nuclear Information System (INIS)

    Sezeur, A.; Goujard, F.; Labriolle-Vaylet, C.L. de; Wioland, M.; Douay, L.; Desmarquet, J.

    1990-01-01

    A case of accessory spleen, 1 cm in diameter, responsible for recurrence of an idiopathic thrombocytopenic purpura after splenectomy is reported. This case is original in that the accessory spleen could only be detected by transoperative scintigraphy. Transoperative scintigraphy is a simple method to be used when one or several unrecognized accessory spleens are responsible for recurrence of a blood disease after excision of the principal spleen [fr

  13. The influence of axle position and the use of accessories on the activity of upper limb muscles during manual wheelchair propulsion.

    Science.gov (United States)

    Bertolaccini, Guilherme da Silva; Carvalho Filho, Idinei Francisco Pires de; Christofoletti, Gustavo; Paschoarelli, Luis Carlos; Medola, Fausto Orsi

    2018-06-01

    Wheelchair configuration is an important factor influencing the ergonomics of the user-device interface and, from a biomechanical point of view, small changes in chair setup may have a positive influence on the demand on the upper limbs during manual propulsion. This study aimed to investigate the influence of the position of the rear wheels' axle and the use of accessories on the activity of upper limb muscles during manual wheelchair propulsion. Electromyography signals of the biceps, triceps, anterior deltoids and pectoralis major were collected for 11 able-bodied subjects in a wheelchair propulsion protocol with four different wheelchair configurations (differing in axle position and the use of accessories) on a straightforward sprint and a slalom course. With accessories, moving the axle forward led to a decrease in the activity of all muscles in both the straightforward sprint (significant differences in triceps, anterior deltoids and biceps) and the slalom course (significant difference in anterior deltoids and biceps). However, when propelling the chair without accessories, no difference was found related to axle position. Changes in wheelchair configuration can influence the ergonomics of manual wheelchair propulsion. Reducing the biomechanical loads may benefit users' mobility, independence and social participation.

  14. Control rod drives

    International Nuclear Information System (INIS)

    Futatsugi, Masao.

    1980-01-01

    Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is actuated to warn the abnormality and the control rod inhibition interlock is actuated to lock the direction control valve thereby secure the safety operation of the reactor. (Seki, T.)

  15. MRI findings of spinal accessory neuropathy

    International Nuclear Information System (INIS)

    Li, A.E.; Greditzer, H.G.; Melisaratos, D.P.; Wolfe, S.W.; Feinberg, J.H.; Sneag, D.B.

    2016-01-01

    Aim: To characterise the magnetic resonance imaging (MRI) appearance of patients with spinal accessory nerve (SAN) denervation. Material and methods: Twelve patients who had SAN denervation on electromyography (EMG) were included. The sternocleidomastoid and trapezius muscles and the SAN were assessed using MRI. Results: Trapezius muscle atrophy was seen in 11 (92%), and of those patients, T2/short tau inversion recovery (STIR) signal hyperintensity was also demonstrated in seven (58%). All three patients with prior neck surgery had scarring around the SAN, and one of these patients demonstrated a neuroma, which was confirmed surgically. Conclusion: Features of SAN neuropathy on MRI include atrophy and T2/STIR signal hyperintensity of the trapezius, and in patients who have had posterior triangle neck surgery, scarring may be seen around the nerve. - Highlights: • Spinal accessory nerve injury is most commonly the result of neck surgery. • MRI findings include trapezius muscle atrophy and T2 signal hyperintensity. • In cases of suspected injury, the course of the spinal accessory nerve should be assessed on MRI.

  16. Prospects for the application of GaN power devices in hybrid electric vehicle drive systems

    Science.gov (United States)

    Su, Ming; Chen, Chingchi; Rajan, Siddharth

    2013-07-01

    GaN, a wide bandgap semiconductor successfully implemented in optical and high-speed electronic devices, has gained momentum in recent years for power electronics applications. Along with rapid progress in material and device processing technologies, high-voltage transistors over 600 V have been reported by a number of teams worldwide. These advances make GaN highly attractive for the growing market of electrified vehicles, which currently employ bipolar silicon devices in the 600-1200 V class for the traction inverter. However, to capture this billion-dollar power market, GaN has to compete with existing IGBT products and deliver higher performance at comparable or lower cost. This paper reviews key achievements made by the GaN semiconductor industry, requirements of the automotive electric drive system and remaining challenges for GaN power devices to fit in the inverter application of hybrid vehicles.

  17. Spinal Accessory Nerve Duplication: A Case Report and Literature Review

    OpenAIRE

    Papagianni, Eleni; Kosmidou, Panagiota; Fergadaki, Sotiria; Pallantzas, Athanasios; Skandalakis, Panagiotis; Filippou, Dimitrios

    2018-01-01

    Aim of the present study is to expand our knowledge of the anatomy of the 11th cranial nerve and discuss the clinical importance and literature pertaining to accessory nerve duplication. We present one case of duplicated spinal accessory nerve in a patient undergoing neck dissection for oral cavity cancer. The literature review confirms the extremely rare diagnosis of a duplicated accessory nerve. Its clinical implication is of great importance. From this finding, a further extension to our k...

  18. Accessory bones of the feet: Radiological analysis of frequency

    Directory of Open Access Journals (Sweden)

    Vasiljević Vladica

    2010-01-01

    Full Text Available Background/Aim. Accessory bones are most commonly found on the feet and they represent an anatomic variant. They occur when there is a failure in the formation of a unique bone from separated centre of ossification. The aim of this study was to establish their frequency and medical significance. Methods. Anteroposterior and lateral foot radiography was performed in 270 patients aged of 20-80 years with a history of trauma (180 and rheumatology disease (90. The presence and distribution of accessory bones was analysed in relation to the total number of patients and their gender. The results are expressed in numeric values and in terms of percentage. Results. Accessory bones were identified in 62 (22.96% patients: 29 (10.74% of them were found in female patients and 33 (12.22% in males. The most common accessory bones were as follows: os tibiale externum 50%, os peroneum 29.03%, ostrigonum 11.29%, os vaselianum 9.68%. Conclusion. Accessory bones found in 23% of patients with trauma and some of rheumatological diseases. Their significance is demonstrated in the differential diagnosis among degenerative diseases, avulsion fractures, muscle and tendon trauma and other types of injuries which can cause painful affection of the foot, as well as in forensic practice.

  19. 26 CFR 48.4161(a)-3 - Parts and accessories.

    Science.gov (United States)

    2010-04-01

    ....4161(a)-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE TAXES MANUFACTURERS AND RETAILERS EXCISE TAXES Sporting Goods § 48.4161(a)-3 Parts and accessories. (a) In general. The tax attaches with respect to parts and accessories for articles specified in...

  20. Complete Spinal Accessory Nerve Palsy From Carrying Climbing Gear.

    Science.gov (United States)

    Coulter, Jess M; Warme, Winston J

    2015-09-01

    We report an unusual case of spinal accessory nerve palsy sustained while transporting climbing gear. Spinal accessory nerve injury is commonly a result of iatrogenic surgical trauma during lymph node excision. This particular nerve is less frequently injured by blunt trauma. The case reported here results from compression of the spinal accessory nerve for a sustained period-that is, carrying a load over the shoulder using a single nylon rope for 2.5 hours. This highlights the importance of using proper load-carrying equipment to distribute weight over a greater surface area to avoid nerve compression in the posterior triangle of the neck. The signs and symptoms of spinal accessory nerve palsy and its etiology are discussed. This report is particularly relevant to individuals involved in mountaineering and rock climbing but can be extended to anyone carrying a load with a strap over one shoulder and across the body. Copyright © 2015 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  1. Cancer of the accessory breast - a case report

    International Nuclear Information System (INIS)

    Madej, B.; Balak, B.; Winkler, I.; Burdan, F.

    2009-01-01

    Breast neoplasm may develop in ectopically located glandular tissue. This paper presents an interesting and rare case of a 50-year-old female who despite regular mammography screening examination developed an invasive accessory breast cancer. Clinical examination revealed a 2 cm - tumour localized 4 cm below the left infra mammary fold. The lesion was immobile, the skin and the atrophic nipple were retracted, the tumour infiltrated the thoracic wall. Oligo biopsy and additional examinations showed an invasive stage IIIB ductal breast cancer (Bloom II, G-2). The receptor status was: ER(+), PGR(+), HER2(-). The increased level of cancer antigen 15.3 was found. The patient was submitted to pre-operative chemotherapy. She also underwent surgery and subsequently post-operative chemotherapy and radiotherapy. On the basis of the presented case, it could be concluded that the accessory mammary glands are out of the image of screening breast examinations. Accessory breast cancer is usually diagnosed by clinical examination and ultrasonography. Preventive resection of accessory breast in women at high risk of developing breast cancer can be considered as the treatment of choice in most patients. (authors)

  2. The accessory magnocellular neurosecretory system of the rostral human hypothalamus

    DEFF Research Database (Denmark)

    Møller, Morten; Busch, Johannes R.; Jacobsen, Christina

    2018-01-01

    magnocellular neurons were often located along the blood vessels and projections of some of these neurons penetrated the vascular endothelium. The accessory magnocellular cell bodies expressed either neurophysin I or neurophysin II immunoreactivity. Summarizing, the accessory magnocellular system in the human......The morphology and neurophysin expression of the magnocellular accessory neuroendocrine system located in the rostral human hypothalamus is investigated in a series of brains obtained at autopsy. The hypothalami were fixed in formalin and embedded in paraffin, or after cryoprotection, frozen...

  3. Prospects for the application of GaN power devices in hybrid electric vehicle drive systems

    International Nuclear Information System (INIS)

    Su, Ming; Chen, Chingchi; Rajan, Siddharth

    2013-01-01

    GaN, a wide bandgap semiconductor successfully implemented in optical and high-speed electronic devices, has gained momentum in recent years for power electronics applications. Along with rapid progress in material and device processing technologies, high-voltage transistors over 600 V have been reported by a number of teams worldwide. These advances make GaN highly attractive for the growing market of electrified vehicles, which currently employ bipolar silicon devices in the 600–1200 V class for the traction inverter. However, to capture this billion-dollar power market, GaN has to compete with existing IGBT products and deliver higher performance at comparable or lower cost. This paper reviews key achievements made by the GaN semiconductor industry, requirements of the automotive electric drive system and remaining challenges for GaN power devices to fit in the inverter application of hybrid vehicles. (invited review)

  4. A rare nasal cavity mass in a child: Accessory middle turbinate

    OpenAIRE

    Chang, Andrew; Ulualp, Seckin O; Koral, Korgun; Veling, Maria

    2016-01-01

    Objectives: The accessory middle turbinate, a rare anatomical variation of the nasal cavity, have been systematically studied in adults. Presence of accessory middle turbinate and its clinical significance in a child has not been reported. We describe clinical appearance and radiologic features of accessory middle turbinate in a child. Methods: Retrospective chart review. Results: A 3-year-old boy presented to the otolaryngology clinic for evaluation of recurrent epistaxis. Anterior rhinoscop...

  5. 19 CFR 10.600 - Accessories, spare parts, or tools.

    Science.gov (United States)

    2010-04-01

    ...-Central America-United States Free Trade Agreement Rules of Origin § 10.600 Accessories, spare parts, or... parts, or tools are customary for the good. (a) Regional value content. If the good is subject to a regional value content requirement, the value of the accessories, spare parts, or tools is taken into...

  6. Chloroquine inhibits accessory cell presentation of soluble natural and synthetic protein antigens

    DEFF Research Database (Denmark)

    Buus, S; Werdelin, O

    1984-01-01

    We have studied the in vitro effect of the lysosomotrophic agent, chloroquine, on the presentation of soluble protein antigens by guinea pig accessory cells. Chloroquine inhibited the capacity of antigen-pulsed accessory cells to stimulate proliferation in appropriately primed T cells. The effect...... was time- and dose-dependent. A brief treatment solely of the accessory cells with the drug compromised their ability to stimulate primed T cells in a subsequent culture provided the accessory cells were treated with chloroquine before their exposure to the antigen. These results suggest that chloroquine...... acts on an early event in the antigen handling by accessory cells. Chloroquine is a well known inhibitor of lysosomal proteolysis, and it is likely that its effect on antigen presentation is caused by an inhibition of antigen degradation....

  7. Case report: accessory head of the deep forearm flexors

    Science.gov (United States)

    JONES, M.; ABRAHAMS, P. H.; SAÑUDO, J. R.

    1997-01-01

    In 1813 Gantzer described 2 accessory muscles in the human forearm which bear his name (Wood, 1868; Macalister, 1875) and these have subsequently been reported with variable attachments (Wood, 1868; Macalister, 1875; Turner, 1879; Schäfer & Thane, 1894; Le Double, 1897; Dykes & Anson, 1944; Mangini, 1960; Malhotra et al. 1982; Kida, 1988; Tountas & Bergman, 1993). The accessory heads of the deep flexors of the forearm (Gantzer's muscles) have been described as 2 different small bellies which insert either into FPL or FDP. There are no previous reports which have mentioned the existence of an accessory muscle which inserts into both of the 2 deep flexors of the forearm as in the case presented here. PMID:9306208

  8. Snapping wrist due to multiple accessory tendon of first extensor compartment

    Directory of Open Access Journals (Sweden)

    S. Dhiyaneswaran Subramaniyam

    2018-01-01

    Conclusion: There are various causes for snapping wrist syndrome. Multiple accessory tendon can also cause snapping as shown in this case report. Moreover am presenting this case to highlight the diagnostic failure with non dynamic radiological investigation and to consider multiple accessory tendon as differential diagnosis for snapping wrist syndrome. Also suggest dynamic study could be a better choice of investigation to diagnosis snapping syndrome. First compartment tunnel release with few accessory tendon slip tenotomy gives good result.

  9. Evolution of the CT imaging findings of accessory spleen infarction

    International Nuclear Information System (INIS)

    Mendi, Resham; Abramson, Lisa P.; Pillai, Srikumar B.; Rigsby, Cynthia K.

    2006-01-01

    We report the case of a 12-year-old girl presenting with multiple episodes of left upper-quadrant pain caused by torsion of an accessory spleen. We present the CT findings of progression of accessory spleen infarction over the course of 7 days. (orig.)

  10. B-mode and contrast-enhanced sonographic assessment of accessory spleen in the dog.

    Science.gov (United States)

    Rossi, Federica; Rabba, Silvia; Vignoli, Massimo; Haers, Hendrik; Terragni, Rossella; Saunders, Jimmy H

    2010-01-01

    Four dogs with an accessory spleen are described. The accessory spleens appeared as a round-to-triangular structure located in the perisplenic area. They were homogeneous and isoechoic with the adjacent spleen. Contrast-enhanced ultrasound was performed using a second generation microbubble contrast medium (sulfur hexafluoride). The type and timing of enhancement of the accessory spleen was similar to that of the parent spleen. Contrast-enhanced ultrasound is a noninvasive modality useful in distinguishing an accessory spleen from a mass of another origin.

  11. Accessory mineral records of tectonic environments? (Invited)

    Science.gov (United States)

    Storey, C.; Marschall, H. R.; Enea, F.; Taylor, J.; Jennings, E. S.

    2010-12-01

    Accessory mineral research continues to gather momentum as we seek to unleash their full potential. It is now widely recognised that robust accessory minerals, such as zircon, rutile, titanite, allanite and monazite, are archives of important trace elements that can help deduce metamorphic reaction history in metapelites, metabasites and other rock types. Moreover, they are important carriers of certain trace elements and govern or influence the products of partial melting and of fluid-rock interaction (e.g. magmas and mineralisation) in settings like subduction zones and hydrothermal systems. Perhaps most importantly, they can often be dated using the U-Th-Pb system. More recently, radiogenic (Lu-Hf, Sm-Nd, Rb-Sr) and stable (O) isotope systems have been applied and have further pushed the utility of accessory mineral research. In this talk I will discuss some of these advances towards one particular aim: the use of detrital accessory minerals for fingerprinting tectonic environments. This is a particularly laudable aim in Precambrian rocks, for which the preservation potential of orogenic belts and fossil subduction zones and their diagnostic metamorphic rocks is low. The implication is that our understanding of plate tectonics, particularly in the Archaean, is biased by the preserved in-tact rock record. An analogy is that Jack Hills zircons record evidence of Earth’s crust some 400 Ma before the preserved rock record begins. I will focus on some recent advances and new data from rutile and also the mineral inclusion record within zircon, which shows great promise for petrologic interpretation.

  12. A rare nasal cavity mass in a child: Accessory middle turbinate

    Directory of Open Access Journals (Sweden)

    Andrew Chang

    2016-09-01

    Full Text Available Objectives: The accessory middle turbinate, a rare anatomical variation of the nasal cavity, have been systematically studied in adults. Presence of accessory middle turbinate and its clinical significance in a child has not been reported. We describe clinical appearance and radiologic features of accessory middle turbinate in a child. Methods: Retrospective chart review. Results: A 3-year-old boy presented to the otolaryngology clinic for evaluation of recurrent epistaxis. Anterior rhinoscopy revealed moist nasal mucosa without inflammation and bilateral prominent blood vessels on the anterior nasal septum. Nasal endoscopy showed turbinate like protuberances in bilateral middle meatus. CT images documented accessory middle turbinate in the bilateral nasal cavity. Conclusion: Otolaryngologists should be cognizant of anatomical variations of middle turbinate to achieve correct diagnosis and avoid potential complications during surgical management.

  13. Testing of marrow coal bed systems by hydraulic driving device for thin films of coal; Ensayo de un Sistema de Arranque con Cepillo mediante Accionamiento Hidraulico para Capas Estrechas de CArbon

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This researching project had the aim of: Testing a new mining system performance at narrow coal bed, which uses plough equipment with hydraulic driving devices. Minimising driving power group size to avoid problems regarding with the wall mining-heading transition, decreasing the needed room to house it and thus simplifying wall mining edge support The expected goals were: Take advantage of hydraulic driving devices to obtain a good efficiency with a variable and discontinuous load, bu t without loosing the electric driving devices advantages, consisting on increase driving torque, being the engine blocked Lengthen the mechanical equipment life (chains, driving sprockets, etc.) Reach and economic production rate Researching project was developed in El Bierzo basin (Leon, Spain), in Grupo Ampliacion, a mining group belonged to Viloria Hnos S. A.. (Author)

  14. Ways of Telecommunications Interaction Arrangement for Microprocessor Devices of Different Types in Composition of Multi-Motor Electric Drives

    Science.gov (United States)

    Shpenst, V. A.; Vasiliev, B. Y.; Kalashnikov, O. V.; Oleynikova, A. M.

    2018-05-01

    The article covers a consideration of various state-of-the-art industrial data transfer protocols, e.g. Modbus, Profibus, Industrial Ethernet and CAN. Their pros and cons are analyzed and conclusions made on advisability of the use of each protocol. It is shown that for the arrangement of effective telecommunication interaction of microprocessor devices of different types in the composition of multi-motor electric drives, it is advisable to use highlevel CAN-protocols, such as CANopen and DeviceNet.

  15. Prototype of a new tip developed to be coupled to dental light-curing units for optimizing bonding of orthodontic brackets and accessories

    Directory of Open Access Journals (Sweden)

    Sergio Luiz Mota Júnior

    2013-12-01

    Full Text Available OBJECTIVE: development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories, and test its efficacy in an in vitro mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of such device is the reduced clinical time needed for bonding and the low possibility of contamination during the process. METHODS: One hundred and twenty specimens were used for testing the shear bond strength of brackets bonded with the device. The Adhesive Remnant Index (ARI was also determined. The sample was divided into 2 groups. In group 1 a halogen light-curing unit was used while in group 2 a led light-curing unit was used. Each group was then subdivided. In subgroups H1 and L1, a conventional light guide rod was used while in subgroups H2 and L2 bonding was performed with the mirrored device coupled to the tip of the guide light rod. RESULTS: The values obtained for the shear bond strength and the ARI in the subgroups were compared. Results showed that there was no statistically significant difference for the shear strength (p > 0.05 and the ARI (p > 0.05 between the subgroups. CONCLUSION: The tests of mechanical trials and the ARI analysis showed that the new device fulfilled the requirements for bonding orthodontic accessories, and that the time for bonding was reduced to half, being necessary only one light exposure.

  16. Accessory spleen compromising response to splenectomy for idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Ambriz, P.; Munoz, R.; Quintanar, E.; Sigler, L.; Aviles, A.; Pizzuto, J.

    1985-01-01

    Accessory spleens were sought in 28 patients who had undergone splenectomy for chronic idiopathic thrombocytopenic purpura (ITP), using a variety of techniques. Abdominal scintigraphy with autologous erythrocytes labeled with Tc-99m and opsonized with anit-D IgG (radioimmune method) proved to be most useful, clearly demonstrating one or more accessory spleens in 12 cases (43%). Computed tomography (CT) was also helpful. Four out of five patients demonstrated an increased platelet count following surgery, the effectiveness of which was illustrated by the radioimmune scan. Patients who have had splenectomy for chronic ITP should be scanned using radioimmune techniques and CT to determine whether an accessory spleen is present

  17. Scrolling and driving: how an MP3 player and its aftermarket controller affect driving performance and visual behavior.

    Science.gov (United States)

    Lee, John D; Roberts, Shannon C; Hoffman, Joshua D; Angell, Linda S

    2012-04-01

    The aim of this study was to assess how scrolling through playlists on an MP3 player or its aftermarket controller affects driving performance and to examine how drivers adapt device use to driving demands. Drivers use increasingly complex infotainment devices that can undermine driving performance. The goal activation hypothesis suggests that drivers might fail to compensate for these demands, particularly with long tasks and large search set sizes. A total of 50 participants searched for songs in playlists of varying lengths using either an MP3 player or an aftermarket controller while negotiating road segments with traffic and construction in a medium-fidelity driving simulator. Searching through long playlists (580 songs) resulted in poor driving performance and required more long glances (longer than 2 s) to the device compared with other playlist lengths. The aftermarket controller also led to more long glances compared with the MP3 player. Drivers did not adequately adapt their behavior to roadway demand, as evident in their degraded driving performance. No significant performance differences were found between short playlists, the radio-tuning task, and the no-task condition. Selecting songs from long playlists undermined driving performance, and drivers did not sufficiently adapt their use of the device to the roadway demands, consistent with the goal activation hypothesis. The aftermarket controller degraded rather than enhanced performance. Infotainment systems should support drivers in managing distraction. Aftermarket controllers can have the unintended effect of making devices carried into the car less compatible with driving.These results can motivate development of new interfaces as alternatives to scrolling lists.

  18. [Evaluation of iatrogenic accessory nerve injury in forensic medical practice].

    Science.gov (United States)

    Somogyi, E; Irányi, J

    1996-04-14

    The authors give a survey of the clinical and medical-legal characteristics of the accessory nerve injury. In the past two decades the conception of the successfulness of the surgical treatment of the accessory nerve injury became prevailing. About the medical-legal aspects of the iatrogenic injury of the nerve reported in connection of the reconstructive surgery chiefly also departments of neurosurgery, orthopedics and traumatology. In the case of the authors a 70 year old patient suffered 10 years ago a iatrogenic accessory nerve injury. The mild trapezius palsy recovered spontaneously practically with cosmetic disadvantage. In connection with the development of extreme dorso-lumbal scoliosis associated with torsion the trapezius atrophy worsened. Physical therapy was partly successful. But the patient became unfit for manual work. Their observations sustain the data of authors who established that in the case of accessory nerve injury not only the surgical but also conservative treatment is usually successful. In opposite to certain data of the literature the authors establish that the iatrogenic injuries of the accessory nerve may lead to significant lifelong disability. The diagnosis is not always made in time with consequent delay in repair. This may be regarded as an unfavorable issue during medical-legal discussions. The authors recommend in interest to prevent nerve injury in the posterior triangle of the neck to perform operation in special department.

  19. Rhabdovirus accessory genes.

    Science.gov (United States)

    Walker, Peter J; Dietzgen, Ralf G; Joubert, D Albert; Blasdell, Kim R

    2011-12-01

    The Rhabdoviridae is one of the most ecologically diverse families of RNA viruses with members infecting a wide range of organisms including placental mammals, marsupials, birds, reptiles, fish, insects and plants. The availability of complete nucleotide sequences for an increasing number of rhabdoviruses has revealed that their ecological diversity is reflected in the diversity and complexity of their genomes. The five canonical rhabdovirus structural protein genes (N, P, M, G and L) that are shared by all rhabdoviruses are overprinted, overlapped and interspersed with a multitude of novel and diverse accessory genes. Although not essential for replication in cell culture, several of these genes have been shown to have roles associated with pathogenesis and apoptosis in animals, and cell-to-cell movement in plants. Others appear to be secreted or have the characteristics of membrane-anchored glycoproteins or viroporins. However, most encode proteins of unknown function that are unrelated to any other known proteins. Understanding the roles of these accessory genes and the strategies by which rhabdoviruses use them to engage, divert and re-direct cellular processes will not only present opportunities to develop new anti-viral therapies but may also reveal aspects of cellar function that have broader significance in biology, agriculture and medicine. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  20. Incore instrumentation device

    International Nuclear Information System (INIS)

    Fujita, Kazuhiko.

    1996-01-01

    A position of a detector is detected by a driving device, and the detected values are sampled by a newly disposed central processing unit for sampling the detected values depending on the sampling position of the detected values. Since the sampling position of the detected values is detected by the driving device, the sampling position for the detection values does not rely on the speed of the driving motor of the driving device. The load on the central processing device for controlling the device is lowered by newly disposing the central processing unit for sampling detected values. When the values for the position of the detector counted after conversion to digital values reach the digital values corresponding to the detection value sampling position outputted from the central processing unit for controlling the device, a counted value comparison circuit causes the central processing unit for controlling the device to sample the detection values outputted from the detector. Then, the processing speed can be increased without interruption processings, which can save the central processing unit for sampling detection values. In addition, software can be simplified and loads can be lowered. (N.H.)

  1. Control device for a nuclear reactor with a multitude of control rods, extending into the reactor core from above, with linear drive mechanisms and additional gripper devices

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1979-01-01

    The components of the additional gripper devices with magnetically operated finger-shaped latches are separated from the also magnetically operated latches of the linear drive mechanisms in order to avoid common-mode failures when fast shutdown is required. Only part of the safety rods are held by the additional gripping devices in the withdrawn position. There is provided for recording elements indicating positively which one of the safety locks is gearing with the control rods. At the upper end of each control rod there is a coupling head held by electromagnetically operated locking devices in the withdrawn position, if control power is available. (DG) [de

  2. Implementation of immobilization accessories for positioning of small animals for radiation therapy

    International Nuclear Information System (INIS)

    Vettorato, M.C.; Girotto, C.H.; Fogaça, J.L.; Vulcano, L.C.; Fernandes, M.A.R.

    2017-01-01

    Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes. (author)

  3. Implementation of immobilization accessories for positioning of small animals for radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Vettorato, M.C.; Girotto, C.H.; Fogaça, J.L.; Vulcano, L.C.; Fernandes, M.A.R., E-mail: m_vettorato@hotmail.com [Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2017-11-15

    Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes. (author)

  4. 21 CFR 876.5540 - Blood access device and accessories.

    Science.gov (United States)

    2010-04-01

    ... vascular graft prosthesis (§§ 870.3450 and 870.3460), and are intended to remain in the body for less than... intended to remain in the body for 30 days or more. This generic type of device includes various shunts and...

  5. Implementation of a map route analysis robot: combining an Android smart device and differential-drive robotic platform

    Directory of Open Access Journals (Sweden)

    Tseng Chi-Hung

    2017-01-01

    Full Text Available This paper proposes an easy-to-implement and relatively low-cost robotic platform with capability to realize image identification, object tracking, and Google Map route planning and navigation. Based on the JAVA and Bluetooth communication architectures, the system demonstrates the integration of Android smart devices and a differential-drive robotic platform.

  6. Do in-car devices affect experienced users' driving performance?

    NARCIS (Netherlands)

    Knapper, A.S.; Hagenzieker, M.P.; Brookhuis, K.A.

    2014-01-01

    Distracted driving is considered to be an important factor in road safety. To investigate how experienced user's driving behaviour is affected by in-vehicle technology, a fixed-base driving simulator was used. 20 participants drove twice in a rich simulated traffic environment while performing

  7. Do in-car devices affect experienced users' driving performance?

    NARCIS (Netherlands)

    Knapper, A.S. Hagenzieker, M.P. & Brookhuis, K.A.

    2015-01-01

    Distracted driving is considered to be an important factor in road safety. To investigate how experienced user's driving behaviour is affected by in-vehicle technology, a fixed-base driving simulator was used. 20 participants drove twice in a rich simulated traffic environment while performing

  8. Accessory renal arteries: Prevalence in resistant hypertension and an important role in nonresponse to radiofrequency renal denervation

    Energy Technology Data Exchange (ETDEWEB)

    VonAchen, Paige [Minneapolis Heart Institute and Foundation at Abbott Northwestern Hospital, Minneapolis, MN (United States); Hamann, Jason [Boston Scientific Corporation, Maple Grove, MN (United States); Houghland, Thomas; Lesser, John R.; Wang, Yale; Caye, David; Rosenthal, Kristi; Garberich, Ross F. [Minneapolis Heart Institute and Foundation at Abbott Northwestern Hospital, Minneapolis, MN (United States); Daniels, Mary [Vital Images/Toshiba, Minnetonka, MN (United States); Schwartz, Robert S., E-mail: rss@rsschwartz.com [Minneapolis Heart Institute and Foundation at Abbott Northwestern Hospital, Minneapolis, MN (United States)

    2016-10-15

    Objective: The aim of this study was to understand the role of accessory renal arteries in resistant hypertension, and to establish their role in nonresponse to radiofrequency renal denervation (RDN) procedures. Background: Prior studies suggest a role for accessory renal arteries in hypertensive syndromes, and recent clinical trials of renal denervation report that these anomalies are highly prevalent in resistant hypertension. This study evaluated the relationships among resistant hypertension, accessory renal arteries, and the response to radiofrequency (RF) renal denervation. Methods: Computed Tomography Angiography (CTA) and magnetic resonance imaging (MRI) scans from 58 patients with resistant hypertension undergoing RF renal denervation (RDN) were evaluated. Results were compared with CT scans in 57 healthy, normotensive subjects undergoing screening as possible renal transplant donors. All scans were carefully studied for accessory renal arteries, and were correlated with long term blood pressure reduction. Results: Accessory renal arteries were markedly more prevalent in the hypertensive patients than normotensive renal donors (59% vs 32% respectively, p = 0.004). RDN had an overall nonresponse rate of 29% (response rate 71%). Patients without accessory vessels had a borderline higher response rate to RDN than those with at least one accessory vessel (83% vs 62% respectively, p = 0.076) and a higher RDN response than patients with untreated accessory arteries (83% vs 55%; p = 0.040). For accessory renal arteries and nonresponse, the sensitivity was 76%, specificity 49%, with positive and negative predictive values 38% and 83% respectively. Conclusions: Accessory renal arteries were markedly over-represented in resistant hypertensives compared with healthy controls. While not all patients with accessory arteries were nonresponders, nonresponse was related to both the presence and non-treatment of accessory arteries. Addressing accessory renal arteries in

  9. Accessory renal arteries: Prevalence in resistant hypertension and an important role in nonresponse to radiofrequency renal denervation

    International Nuclear Information System (INIS)

    VonAchen, Paige; Hamann, Jason; Houghland, Thomas; Lesser, John R.; Wang, Yale; Caye, David; Rosenthal, Kristi; Garberich, Ross F.; Daniels, Mary; Schwartz, Robert S.

    2016-01-01

    Objective: The aim of this study was to understand the role of accessory renal arteries in resistant hypertension, and to establish their role in nonresponse to radiofrequency renal denervation (RDN) procedures. Background: Prior studies suggest a role for accessory renal arteries in hypertensive syndromes, and recent clinical trials of renal denervation report that these anomalies are highly prevalent in resistant hypertension. This study evaluated the relationships among resistant hypertension, accessory renal arteries, and the response to radiofrequency (RF) renal denervation. Methods: Computed Tomography Angiography (CTA) and magnetic resonance imaging (MRI) scans from 58 patients with resistant hypertension undergoing RF renal denervation (RDN) were evaluated. Results were compared with CT scans in 57 healthy, normotensive subjects undergoing screening as possible renal transplant donors. All scans were carefully studied for accessory renal arteries, and were correlated with long term blood pressure reduction. Results: Accessory renal arteries were markedly more prevalent in the hypertensive patients than normotensive renal donors (59% vs 32% respectively, p = 0.004). RDN had an overall nonresponse rate of 29% (response rate 71%). Patients without accessory vessels had a borderline higher response rate to RDN than those with at least one accessory vessel (83% vs 62% respectively, p = 0.076) and a higher RDN response than patients with untreated accessory arteries (83% vs 55%; p = 0.040). For accessory renal arteries and nonresponse, the sensitivity was 76%, specificity 49%, with positive and negative predictive values 38% and 83% respectively. Conclusions: Accessory renal arteries were markedly over-represented in resistant hypertensives compared with healthy controls. While not all patients with accessory arteries were nonresponders, nonresponse was related to both the presence and non-treatment of accessory arteries. Addressing accessory renal arteries in

  10. Gripper driving device for moving a fuel up and down in a reactor

    International Nuclear Information System (INIS)

    Hatakenaka, Hideo.

    1975-01-01

    Object: To use a rope in one system to effect upward and downward movement of the gripper and opening and closing operation of a gripper opening and closing pawl to make the device smaller and the mechanism simpler. Structure: The device comprises two rope winding drums synchronously driven by a driving source for upward and downward movement of a gripper, a guide pulley arranged upwardly of each rope winding drum and displaced in relatively up and down opposite direction by a pawl operating portion for opening and closing the gripper, a gripper provided with a double-arm oscillating lever for suspending and supporting a rope and operating the opening and closing pawl supported within the gripper body and an actuator for operating the opening and closing pawl interlocked and connected to said lever, and two ropes mounted on the double arm lever of the gripper passing over the guide pulleys from the winding drums. (Kamimura, M.)

  11. Heating and current drive on NSTX

    Science.gov (United States)

    Wilson, J. R.; Batchelor, D.; Carter, M.; Hosea, J.; Ignat, D.; LeBlanc, B.; Majeski, R.; Ono, M.; Phillips, C. K.; Rogers, J. H.; Schilling, G.

    1997-04-01

    Low aspect ratio tokamaks pose interesting new challenges for heating and current drive. The NSTX (National Spherical Tokamak Experiment) device to be built at Princeton is a low aspect ratio toroidal device that has the achievement of high toroidal beta (˜45%) and non-inductive operation as two of its main research goals. To achieve these goals significant auxiliary heating and current drive systems are required. Present plans include ECH (Electron cyclotron heating) for pre-ionization and start-up assist, HHFW (high harmonic fast wave) for heating and current drive and eventually NBI (neutral beam injection) for heating, current drive and plasma rotation.

  12. MERS-CoV Accessory ORFs Play Key Role for Infection and Pathogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Menachery, Vineet D.; Mitchell, Hugh D.; Cockrell, Adam S.; Gralinski, Lisa E.; Yount, Boyd L.; Graham, Rachel L.; McAnarney, Eileen T.; Douglas, Madeline G.; Scobey, Trevor; Beall, Anne; Dinnon, Kenneth; Kocher, Jacob F.; Hale, Andrew E.; Stratton, Kelly G.; Waters, Katrina M.; Baric, Ralph S.; Racaniello, Vincent R.

    2017-08-22

    ABSTRACT

    While dispensable for viral replication, coronavirus (CoV) accessory open reading frame (ORF) proteins often play critical roles during infection and pathogenesis. Utilizing a previously generated mutant, we demonstrate that the absence of all four Middle East respiratory syndrome CoV (MERS-CoV) accessory ORFs (deletion of ORF3, -4a, -4b, and -5 [dORF3-5]) has major implications for viral replication and pathogenesis. Importantly, attenuation of the dORF3-5 mutant is primarily driven by dysregulated host responses, including disrupted cell processes, augmented interferon (IFN) pathway activation, and robust inflammation.In vitroreplication attenuation also extends toin vivomodels, allowing use of dORF3-5 as a live attenuated vaccine platform. Finally, examination of ORF5 implicates a partial role in modulation of NF-κB-mediated inflammation. Together, the results demonstrate the importance of MERS-CoV accessory ORFs for pathogenesis and highlight them as potential targets for surveillance and therapeutic treatments moving forward.

    IMPORTANCEThe initial emergence and periodic outbreaks of MERS-CoV highlight a continuing threat posed by zoonotic pathogens to global public health. In these studies, mutant virus generation demonstrates the necessity of accessory ORFs in regard to MERS-CoV infection and pathogenesis. With this in mind, accessory ORF functions can be targeted for both therapeutic and vaccine treatments in response to MERS-CoV and related group 2C coronaviruses. In addition, disruption of accessory ORFs in parallel may offer a rapid response platform to attenuation of future emergent strains based on both SARS- and MERS-CoV accessory ORF mutants.

  13. Hydraulic system for the drive of control rod

    International Nuclear Information System (INIS)

    Niwano, Masao.

    1978-01-01

    Purpose: To remove thermal stress and improve safety by utilizing water discharged a driving device as a part of cooling water for the device upon driving of control rods. Constitution: A water drain valve is wholly closed and a flow stabilization valve is supplied with an amount of water necessary for driving control rods. Upon driving one control rod, an amount of water required for the driving is caused to flow to the relivant hydraulic control unit and the flow rate in the stabilization valve is reduced by an amount required for the driving to keep the flow rate constant in the flow control valve. Since Excess water conventionally returned to the pressure vessel is utilized as cooling water for the driving device of control rods, the pressure vessel nozzle can be saved. Accordingly, the thermal stress in the nozzle portion can be removed to significantly improve the safety. (Seki, T.)

  14. 26 CFR 48.4061(b)-2 - Definition of parts or accessories.

    Science.gov (United States)

    2010-04-01

    .... Examples of articles which are taxable as parts or accessories are: Automobile air conditioners; baby seats...) MISCELLANEOUS EXCISE TAXES MANUFACTURERS AND RETAILERS EXCISE TAXES Motor Vehicles, Tires, Tubes, Tread Rubber... motors, and other automobile parts or accessories. (c) Materials of a general use—(1) General rule. The...

  15. Deleterious effect of ultraviolet-B radiation on accessory function of human blood adherent mononuclear cells

    International Nuclear Information System (INIS)

    Rich, E.A.; Elmets, C.A.; Fujiwara, H.; Wallis, R.S.; Ellner, J.J.

    1987-01-01

    The effects of ultraviolet-B radiation (UV-B) on accessory function of human blood adherent mononuclear cells (ADH) for antigen and mitogen-induced responses, and production by ADH of the amplifying cytokine interleukin 1 (IL-1) were examined. Responder lymphocytes were rendered accessory cell dependent by treatment of nonadherent cells with OKIal + complement. UV-B depressed accessory function of ADH in a dose-dependent manner. UV-B decreased accessory function of ADH for tetanus toxoid-induced responses and phytohaemagglutinin-induced responses. UV-B also decreased accessory activity of peripheral blood mononuclear cells but not Epstein-Barr virus-transformed B cells for a PPD-reactive T cell line. Interleukin 1 (IL-1) activity of supernatants of ADH was assayed on C3H/HeJ mouse thymocytes. Pretreatment of ADH with UV-B decreased lipopolysaccharide-stimulated IL-1 activity. Lysates of UV-B irradiated, LPS-stimulated ADH had no discernible IL-1 activity. Addition of IL-1 partially restored accessory activity of UV-B irradiated ADH for lymphocyte responses to TT. Exposure of ADH to TT or PHA for 30 min before irradiation blocked the inhibitory effect of UV-B on accessory activity. Thus, low doses of UV-B are deleterious to accessory function and to production of IL-1 by ADH. Interference with production of cytokines and with initial interactions of accessory cells with antigen and mitogen may be critical to the effects of UV-B on immunoregulatory function of ADH. (author)

  16. Electrophysiology of Cranial Nerve Testing: Spinal Accessory and Hypoglossal Nerves.

    Science.gov (United States)

    Stino, Amro M; Smith, Benn E

    2018-01-01

    Multiple techniques have been developed for the electrodiagnostic evaluation of cranial nerves XI and XII. Each of these carries both benefits and limitations, with more techniques and data being available in the literature for spinal accessory than hypoglossal nerve evaluation. Spinal accessory and hypoglossal neuropathy are relatively uncommon cranial mononeuropathies that may be evaluated in the outpatient electrodiagnostic laboratory setting. A review of available literature using PubMed was conducted regarding electrodiagnostic technique in the evaluation of spinal accessory and hypoglossal nerves searching for both routine nerve conduction studies and repetitive nerve conduction studies. The review provided herein provides a resource by which clinical neurophysiologists may develop and implement clinical and research protocols for the evaluation of both of these lower cranial nerves in the outpatient setting.

  17. Naturalistic driving observations of manual and visual-manual interactions with navigation systems and mobile phones while driving.

    NARCIS (Netherlands)

    Christoph, M. Nes, N. van & Knapper, A.

    2014-01-01

    This paper discusses a naturalistic driving study on the use of mobile phones and navigation systems while driving. Manual interactions with these devices while driving can cause distraction from the driving task and reduce traffic safety. In this study 21 subjects were observed for 5 weeks. Their

  18. Accessory renal arteries: Prevalence in resistant hypertension and an important role in nonresponse to radiofrequency renal denervation.

    Science.gov (United States)

    VonAchen, Paige; Hamann, Jason; Houghland, Thomas; Lesser, John R; Wang, Yale; Caye, David; Rosenthal, Kristi; Garberich, Ross F; Daniels, Mary; Schwartz, Robert S

    The aim of this study was to understand the role of accessory renal arteries in resistant hypertension, and to establish their role in nonresponse to radiofrequency renal denervation (RDN) procedures. Prior studies suggest a role for accessory renal arteries in hypertensive syndromes, and recent clinical trials of renal denervation report that these anomalies are highly prevalent in resistant hypertension. This study evaluated the relationships among resistant hypertension, accessory renal arteries, and the response to radiofrequency (RF) renal denervation. Computed Tomography Angiography (CTA) and magnetic resonance imaging (MRI) scans from 58 patients with resistant hypertension undergoing RF renal denervation (RDN) were evaluated. Results were compared with CT scans in 57 healthy, normotensive subjects undergoing screening as possible renal transplant donors. All scans were carefully studied for accessory renal arteries, and were correlated with long term blood pressure reduction. Accessory renal arteries were markedly more prevalent in the hypertensive patients than normotensive renal donors (59% vs 32% respectively, p=0.004). RDN had an overall nonresponse rate of 29% (response rate 71%). Patients without accessory vessels had a borderline higher response rate to RDN than those with at least one accessory vessel (83% vs 62% respectively, p=0.076) and a higher RDN response than patients with untreated accessory arteries (83% vs 55%; p=0.040). For accessory renal arteries and nonresponse, the sensitivity was 76%, specificity 49%, with positive and negative predictive values 38% and 83% respectively. Accessory renal arteries were markedly over-represented in resistant hypertensives compared with healthy controls. While not all patients with accessory arteries were nonresponders, nonresponse was related to both the presence and non-treatment of accessory arteries. Addressing accessory renal arteries in future clinical trials may improve RDN therapeutic efficacy

  19. Heating and current drive on NSTX

    International Nuclear Information System (INIS)

    Wilson, J.R.; Batchelor, D.; Carter, M.; Hosea, J.; Ignat, D.; LeBlanc, B.; Majeski, R.; Ono, M.; Phillips, C.K.; Rogers, J.H.; Schilling, G.

    1997-01-01

    Low aspect ratio tokamaks pose interesting new challenges for heating and current drive. The NSTX (National Spherical Tokamak Experiment) device to be built at Princeton is a low aspect ratio toroidal device that has the achievement of high toroidal beta (∼45%) and non-inductive operation as two of its main research goals. To achieve these goals significant auxiliary heating and current drive systems are required. Present plans include ECH (Electron cyclotron heating) for pre-ionization and start-up assist, HHFW (high harmonic fast wave) for heating and current drive and eventually NBI (neutral beam injection) for heating, current drive and plasma rotation. copyright 1997 American Institute of Physics

  20. Reverse bistable effect in ferroelectric liquid crystal devices with ultra-fast switching at low driving voltage.

    Science.gov (United States)

    Guo, Qi; Zhao, Xiaojin; Zhao, Huijie; Chigrinov, V G

    2015-05-15

    In this Letter, reverse bistable effect with deep-sub-millisecond switching time is first reported in ferroelectric liquid crystal (FLC) devices using a homogeneous photo-alignment technique. It is indicated by our experimental results that both the anchoring energy and the dielectric property of the FLC's alignment layer is critical for the existence of the reverse bistable effect. In addition, with the derived criteria of the reverse bistable effect, we quantitatively analyze the switching dynamics of the reverse bistable FLC and the transition condition between the traditional bistability and our presented reverse bistability. Moreover, the fabricated FLC device exhibits an ultra-fast switching of ∼160  μs and a high contrast ratio of 1000:1, both of which were measured at a low driving voltage of 11 V. The featured deep-sub-millisecond switching time is really advantageous for our presented reverse bistable FLC devices, which enables a significant quality improvement of the existing optical devices, as well as a wide range of new applications in photonics and display areas.

  1. Role of the Accessory Parotid Gland in the Etiology of Parotitis: Statistical Analysis of Sialographic Features.

    Science.gov (United States)

    Zhu, Wangyong; Hu, Fengchun; Liu, Xingguang; Guo, Songcan; Tao, Qian

    2016-01-01

    This retrospective study aimed to identify if the existence of the accessory parotid gland correlated with the etiology of parotitis. This may aid the development of better treatment strategies in the future. Sialographic features of cases with parotitis and healthy subjects were reviewed. The chi-square test was used to compare the incidence of accessory parotid gland between the groups. The Student's t test was used to compare the length of Stensen's duct, the length from the orifice to the confluence of the accessory duct, and the angle between the accessory duct and Stensen's duct between the groups. The incidence of accessory parotid gland in patients with parotitis was 71.8% (28/39), which was significantly higher than that in healthy subjects (P = 0.005). Patients with parotitis had a longer Stensen's duct than healthy subjects (P = 0.003). There was no significant difference in the length from the orifice to the confluence of the accessory duct or the angle between the accessory duct and Stensen's duct (P = 0.136 and 0.511, respectively) between the groups. The accessory parotid gland might play a role in the pathogenesis of parotitis. The existence of an accessory parotid gland is likely to interfere with salivary flow. Computational fluid dynamics analysis of salivary flow in the ductal system would be useful in future etiologic studies on parotitis.

  2. Integrated control rod monitoring device

    International Nuclear Information System (INIS)

    Saito, Katsuhiro

    1997-01-01

    The present invention provides a device in which an entire control rod driving time measuring device and a control rod position support device in a reactor building and a central control chamber are integrated systematically to save hardwares such as a signal input/output device and signal cables between boards. Namely, (1) functions of the entire control rod driving time measuring device for monitoring control rods which control the reactor power and a control rod position indication device are integrated into one identical system. Then, the entire devices can be made compact by the integration of the functions. (2) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated in a central operation board and a board in the site. Then, the place for the installation of them can be used in common in any of the cases. (3) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated to one identical system to save hardware to be used. Then, signal input/output devices and drift branching panel boards in the site and the central operation board can be saved, and cables for connecting both of the boards is no more necessary. (I.S.)

  3. Development and evaluation of accessories to improve the posture of veterinary surgeons in surgical procedures conducted in the field

    Directory of Open Access Journals (Sweden)

    V.A.S. Vulcani

    Full Text Available ABSTRACT The study was conducted based on the information collected on rural properties in the state of Goiás, during practical classes of Surgical Clinic in Large Animals at the Veterinary Hospital of the Escola de Veterinária e Zootecnia of the Universidade Federal de Goiás and during the implementation of outreach projects developed by the institution. An acropostite-phimosis surgical procedure in the bulls in the field was selected, lasting over 30 minutes and requiring movements, posture and strength on the part of the surgeon. Devices were proposed and developed to provide improved comfort and safety to surgeons. The first device was a stool to be used by the professional during the execution of the surgical intervention. The use enabled the surgeon to sit down and rest their feet on the ground, reducing knee bending and distributing the support forces in various muscle groups. For the movement restriction of the surgeon, another accessory was developed to support the foreskin of the animal. Made of wood, this other device serves as a support for keeping the foreskin away from the ground and close to the surgeon. Its length, width and thickness established a good relation with the stool height, providing minimal discomfort to the professional. The third device was designed to assist in the immobilization of the animal and increase safety for the patient and surgical team. A fourth accessory was designed to protect the scapular region and avoid the occurrence of injuries in the radial nerve, myopathies and traumas during the rollover or prolonged stay of the animal in lateral decubitus. The choice of the shape, dimensions and softness of the device was mainly based on the weight of the animal. Such devices have proven to be effective, reducing the time of surgery, making cervical and lumbar movement easier, in addition to providing better support to the surgeon, reducing risks of musculoskeletal diseases.

  4. Torsion of the accessory spleen with infarction : CT features in a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jung Kyung; Lee, Jun Sik; Kim, Mee Eun; Pyun, Hae Wook; Lee, Il Gi; Lee, Jong Gil; Kim, Hee Jin; Kim, Ik Su [Fatima Hospital, Taegu (Korea, Republic of)

    2000-05-01

    Torsion of the accessory spleen is a rare entity that can have variable clinical presentations. We report case involving an 11-year-old boy with severe abdominal pain and a mass that was found to be due to infarction of the accessory spleen, which was twisted on its pedicle. CT revealed a low-attenuating mass with peripheral inflammatory changes in the left upper abdomen. The mass was pathologically confirmed as torsion of the accessory spleen with infarction. (author)

  5. An Accessory Muscle of Pectoral Region: A Case Report

    Science.gov (United States)

    Bannur, B.M.; Mallashetty, Nagaraj; Endigeri, Preetish

    2013-01-01

    Among the variations of pectoral muscles, this case appears to be unique in the literature. This was a case of an accessory pectoral muscle which was located between pectoralis major and pectoralis minor muscles, which was discovered during a routine anatomy dissection. The accessory muscle originated from 6th and 7th ribs at costo-chondral junction, which travelled supero-laterally and inserted by fusing with fibres of pectoralis minor. This unusual muscle holds importance for surgeons while they perform dissectomies, in avoiding complications. PMID:24179919

  6. Integrated Inverter For Driving Multiple Electric Machines

    Science.gov (United States)

    Su, Gui-Jia [Knoxville, TN; Hsu, John S [Oak Ridge, TN

    2006-04-04

    An electric machine drive (50) has a plurality of inverters (50a, 50b) for controlling respective electric machines (57, 62), which may include a three-phase main traction machine (57) and two-phase accessory machines (62) in a hybrid or electric vehicle. The drive (50) has a common control section (53, 54) for controlling the plurality of inverters (50a, 50b) with only one microelectronic processor (54) for controlling the plurality of inverters (50a, 50b), only one gate driver circuit (53) for controlling conduction of semiconductor switches (S1-S10) in the plurality of inverters (50a, 50b), and also includes a common dc bus (70), a common dc bus filtering capacitor (C1) and a common dc bus voltage sensor (67). The electric machines (57, 62) may be synchronous machines, induction machines, or PM machines and may be operated in a motoring mode or a generating mode.

  7. Wolff-Parkinson-White Syndrome and Accessory Pathways

    Science.gov (United States)

    ... the American Heart Association Cardiology Patient Page Wolff-Parkinson-White Syndrome and Accessory Pathways James Kulig , Bruce ... rate, which can be dangerous. What is Wolff-Parkinson-White Syndrome? Wolff-Parkinson-White syndrome (WPW) is ...

  8. ACCESSORIES OF FISCAL OBLIGATION. LEGAL REGIME

    Directory of Open Access Journals (Sweden)

    RADA POSTOLACHE

    2012-05-01

    Full Text Available The interest – which is an institution typical to private law, has been taken over by the fiscal field and adapted to the specific features of fiscal obligation – being defined by its imperative legal regime, which has at the least the following characteristic elements: unitary character, imposed legal percentage, compulsory demand of interest, automatic application. In order to render responsible fiscal debtors, the lawmaker has reintroduced, as an accessory of fiscal obligation, delayed payment penalties, which have a distinct nature and legal regime, but without the principle non bis in idem being transgressed. Our study aims to establish the legal regime ofaccessories typical to fiscal obligation, from the perspective of special normative acts, but also of the common law within the field – Civil Code and Government Ordinance No. 13/2011 – by pointing out at the same time both the particular circumstances and procedural ones regulated by the Fiscal Procedure Code, shedding light upon the controversial legal nature of accessories.

  9. KNOW-BLADE Task-2 report: Aerodynamic accessories

    DEFF Research Database (Denmark)

    Johansen, J.; Sørensen, Niels N.; Zahle, Frederik

    2004-01-01

    In the EC project KNOW-BLADE a work package has been defined to investigate the possibility to numerically model aerodynamic accessories in existing Navier-Stokes solvers. Four different aerodynamic accessories have been investigated. Firstly, thepotential of applying active flow control by means...... of the stall strip. Finally, the effect of surface roughness was modelled by either modifying the boundary condition of the turbulence model or by modifying the airfoil geometry. Using the roughness model gave relatively good agreement withmeasurements and it must be concluded that the effect of using...... to increase the oscillation amplitude, which is not very attractive for load control on wind turbines. Secondly, the effect of vortex generators hasbeen modelled using two phenomenological vortex generator models. The models have been applied to three airfoil configurations. For all cases investigated...

  10. Talking on a Wireless Cellular Device While Driving: Improving the Validity of Crash Odds Ratio Estimates in the SHRP 2 Naturalistic Driving Study

    Directory of Open Access Journals (Sweden)

    Richard A. Young

    2017-12-01

    Full Text Available Dingus and colleagues (Proc. Nat. Acad. Sci. U.S.A. 2016, 113, 2636–2641 reported a crash odds ratio (OR estimate of 2.2 with a 95% confidence interval (CI from 1.6 to 3.1 for hand-held cell phone conversation (hereafter, “Talk” in the SHRP 2 naturalistic driving database. This estimate is substantially higher than the effect sizes near one in prior real-world and naturalistic driving studies of conversation on wireless cellular devices (whether hand-held, hands-free portable, or hands-free integrated. Two upward biases were discovered in the Dingus study. First, it selected many Talk-exposed drivers who simultaneously performed additional secondary tasks besides Talk but selected Talk-unexposed drivers with no secondary tasks. This “selection bias” was removed by: (1 filtering out records with additional tasks from the Talk-exposed group; or (2 adding records with other tasks to the Talk-unexposed group. Second, it included records with driver behavior errors, a confounding bias that was also removed by filtering out such records. After removing both biases, the Talk OR point estimates declined to below 1, now consistent with prior studies. Pooling the adjusted SHRP 2 Talk OR estimates with prior study effect size estimates to improve precision, the population effect size for wireless cellular conversation while driving is estimated as 0.72 (CI 0.60–0.88.

  11. Headgear Accessories Classification Using an Overhead Depth Sensor

    Directory of Open Access Journals (Sweden)

    Carlos A. Luna

    2017-08-01

    Full Text Available In this paper, we address the generation of semantic labels describing the headgear accessories carried out by people in a scene under surveillance, only using depth information obtained from a Time-of-Flight (ToF camera placed in an overhead position. We propose a new method for headgear accessories classification based on the design of a robust processing strategy that includes the estimation of a meaningful feature vector that provides the relevant information about the people’s head and shoulder areas. This paper includes a detailed description of the proposed algorithmic approach, and the results obtained in tests with persons with and without headgear accessories, and with different types of hats and caps. In order to evaluate the proposal, a wide experimental validation has been carried out on a fully labeled database (that has been made available to the scientific community, including a broad variety of people and headgear accessories. For the validation, three different levels of detail have been defined, considering a different number of classes: the first level only includes two classes (hat/cap, and no hat/cap, the second one considers three classes (hat, cap and no hat/cap, and the last one includes the full class set with the five classes (no hat/cap, cap, small size hat, medium size hat, and large size hat. The achieved performance is satisfactory in every case: the average classification rates for the first level reaches 95.25%, for the second one is 92.34%, and for the full class set equals 84.60%. In addition, the online stage processing time is 5.75 ms per frame in a standard PC, thus allowing for real-time operation.

  12. Does the presence of accessory renal arteries affect the efficacy of renal denervation?

    Science.gov (United States)

    Id, Dani; Kaltenbach, Benjamin; Bertog, Stefan C; Hornung, Marius; Hofmann, Ilona; Vaskelyte, Laura; Sievert, Horst

    2013-10-01

    This study sought to assess the efficacy of catheter-based renal sympathetic denervation in patients with accessory renal arteries and to compare the blood pressure (BP)-lowering effect with that observed in patients with bilateral single renal arteries after renal denervation. Catheter-based renal sympathetic denervation causes significant BP reductions in patients with resistant hypertension. Seventy-four patients were included in this study. Patients were assigned to 2 main groups: a bilateral single renal arteries group I (n = 54) and an accessory renal arteries group II (n = 20). Group II consisted of 9 patients whose accessory renal arteries were all denervated (group IIa), and 11 patients whose accessory renal arteries were not, or only incompletely, denervated (group IIb). The primary endpoint was the change in office systolic BP after 6 months. The procedure was successful in all patients. Group I: mean BP at baseline was 166.2/89.4 ± 20.5/14.6 mm Hg and decreased by -16.6 (p renal denervation in patients with accessory renal arteries is less pronounced than in patients with bilateral single renal arteries. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Accessory tragi in three successive generations

    Directory of Open Access Journals (Sweden)

    Vora N

    1996-01-01

    Full Text Available A 40-year-old man presented with clinical and histopathological features of accessory tragi. His father and 3 sons and 1 daughter had similar lesions. In view of this vertical transmission through 3 successive generations involving both the sexes, an autosomal dominant mode of inheritance is suggested.

  14. 29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto. (a) Except as noted in paragraph (e) of this section, cranes and other hoisting machines, together...

  15. Innovative usage of accessory auricles as full-thickness skin graft

    Directory of Open Access Journals (Sweden)

    Elankumar Subbarayan

    2017-01-01

    Full Text Available Accessory auricles are relatively rare malformations arising from the first branchial arch which contains skin, fat and cartilage. The treatment is usually surgical removal for the cosmetic purpose. We are sharing our experience of utilising the accessory auricle skin as full thickness graft for post.burn reconstruction of the fingers contracture of a child. Even though this type of association is rare, it is an innovative idea following Sir Harold Gilles’ principle ‘Never throw anything away’.

  16. Bilateral Tensor Fasciae Suralis Muscles in a Cadaver with Unilateral Accessory Flexor Digitorum Longus Muscle

    Directory of Open Access Journals (Sweden)

    Logan S. W. Bale

    2017-01-01

    Full Text Available Muscle variants are routinely encountered in the dissection laboratory and in clinical practice and therefore anatomists and clinicians need to be aware of their existence. Here we describe two different accessory muscles identified while performing educational dissection of a 51-year-old male cadaver. Tensor fasciae suralis, a rare muscle variant, was identified bilaterally and accessory flexor digitorum longus, a more common muscle variant, was present unilaterally. Tensor fasciae suralis and accessory flexor digitorum longus are clinically relevant muscle variants. To our knowledge, the coexistence of tensor fasciae suralis and accessory flexor digitorum longus in the same individual has not been reported in either cadaveric or imaging studies.

  17. Accessory Axillary Breast Excision with Liposuction Using Minimal Incision: A Preliminary Report.

    Science.gov (United States)

    Hwang, Seong Bae; Choi, Byung Seo; Byun, Geon Young; Koo, Bum Hwan; Lee, Sung Ryul

    2017-02-01

    Accessory breasts have received little attention in the surgical fields, although the condition is quite common in the female population, with 2-6% of women suffering from it. Its convexity and cyclic pain make women feel embarrassed and uncomfortable, so patients often desire surgical excision to improve their appearances and to remove the pain. A total of 967 patients who had been treated by an excision of accessory breast tissue with liposuction using minimal incision from September 2013 to Dec 2015 at the Damsoyu Hospital were analyzed for clinical factors retrospectively. All 967 patients were female. There were 514 (53.2%) unmarried patients and 453 (46.8%) married patients. The major clinical manifestation was the problem in the appearance with cyclic pain in both unmarried and married groups (82.7 vs. 87.9%). Three types of accessory breasts were observed: 779 (80.6%) breast tissue only in axillae, 182 (18.8%) breast tissue with accessory nipple, and 6 (0.6%) breast tissue with accessory nipple-areolar complex. The mean operation time was 58 min. All cyclic axillar pain in our cases was resolved after the operation. Postoperative complications developed in 160 patients (16.55%). Among them, seroma after operation was the most common (11.27%). In our study, 95.65% of the patients were satisfied with the cosmetic outcomes. The surgical excision of accessory breasts with liposuction through the minimal incision is a safe and effective method to make women feel comfortable in clinical manifestations and be satisfied with their cosmetic axillar line. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  18. Development and interval testing of a naturalistic driving methodology to evaluate driving behavior in clinical research.

    Science.gov (United States)

    Babulal, Ganesh M; Addison, Aaron; Ghoshal, Nupur; Stout, Sarah H; Vernon, Elizabeth K; Sellan, Mark; Roe, Catherine M

    2016-01-01

    Background : The number of older adults in the United States will double by 2056. Additionally, the number of licensed drivers will increase along with extended driving-life expectancy. Motor vehicle crashes are a leading cause of injury and death in older adults. Alzheimer's disease (AD) also negatively impacts driving ability and increases crash risk. Conventional methods to evaluate driving ability are limited in predicting decline among older adults. Innovations in GPS hardware and software can monitor driving behavior in the actual environments people drive in. Commercial off-the-shelf (COTS) devices are affordable, easy to install and capture large volumes of data in real-time. However, adapting these methodologies for research can be challenging. This study sought to adapt a COTS device and determine an interval that produced accurate data on the actual route driven for use in future studies involving older adults with and without AD.  Methods : Three subjects drove a single course in different vehicles at different intervals (30, 60 and 120 seconds), at different times of day, morning (9:00-11:59AM), afternoon (2:00-5:00PM) and night (7:00-10pm). The nine datasets were examined to determine the optimal collection interval. Results : Compared to the 120-second and 60-second intervals, the 30-second interval was optimal in capturing the actual route driven along with the lowest number of incorrect paths and affordability weighing considerations for data storage and curation. Discussion : Use of COTS devices offers minimal installation efforts, unobtrusive monitoring and discreet data extraction.  However, these devices require strict protocols and controlled testing for adoption into research paradigms.  After reliability and validity testing, these devices may provide valuable insight into daily driving behaviors and intraindividual change over time for populations of older adults with and without AD.  Data can be aggregated over time to look at changes

  19. Electrophysiological mapping of the accessory olfactory bulb of the rabbit (Oryctolagus cuniculus).

    Science.gov (United States)

    van Groen, T; Ruardy, L; da Silva, F H

    1986-07-01

    Field potentials elicited by electrical stimulation of the vomeronasal nerve were measured in the accessory olfactory bulb of the rabbit. Maps were made of the distribution of surface field potentials and of the corresponding depth profiles. The surface maps followed closely the contours of the accessory olfactory bulb: at the frontal border the field potential tended to zero and at the center of the structure the field potential attained a maximum. Depth profiles of the field potentials through the accessory olfactory bulb presented a surface-negative wave and, in depth, a positive wave. The polarity reversal occurred at the deep part of the granule cell layer. The zero equipotential line followed closely the curvature of the granule cell layer. Current source density analysis of the depth profiles revealed a main sink at the external plexiform and granule cell layers. This indicates that the main activity in the accessory olfactory bulb is generated by the synapses between the mitral cells and the granule cells as is found in the main olfactory bulb.

  20. Spinal Accessory Motor Neurons in the Mouse: A Special Type of Branchial Motor Neuron?

    Science.gov (United States)

    Watson, Charles; Tvrdik, Petr

    2018-04-16

    The spinal accessory nerve arises from motor neurons in the upper cervical spinal cord. The axons of these motor neurons exit dorsal to the ligamentum denticulatum and form the spinal accessory nerve. The nerve ascends in the spinal subarachnoid space to enter the posterior cranial fossa through the foramen magnum. The spinal accessory nerve then turns caudally to exit through the jugular foramen alongside the vagus and glossopharyngeal nerves, and then travels to supply the sternomastoid and trapezius muscles in the neck. The unusual course of the spinal accessory nerve has long prompted speculation that it is not a typical spinal motor nerve and that it might represent a caudal remnant of the branchial motor system. Our cell lineage tracing data, combined with images from public databases, show that the spinal accessory motor neurons in the mouse transiently express Phox2b, a transcription factor that is required for development of brain stem branchial motor nuclei. While this is strong prima facie evidence that the spinal accessory motor neurons should be classified as branchial motor, the evolutionary history of these motor neurons in anamniote vertebrates suggests that they may be considered to be an atypical branchial group that possesses both branchial and somatic characteristics. Anat Rec, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  1. Reactor control device

    International Nuclear Information System (INIS)

    Fukami, Haruo; Morimoto, Yoshinori.

    1981-01-01

    Purpose: To operate a reactor always with safety operation while eliminating the danger of tripping. Constitution: In a reactor control device adapted to detect the process variants of a reactor, control a control rod drive controlling system based on the detected signal to thereby control the driving the control rods, control the reactor power and control the electric power generated from an electric generator by the output from the reactor, detection means is provided for the detection of the electric power from said electric generator, and a compensation device is provided for outputting control rod driving compensation signals to the control rod driving controlling system in accordance with the amount of variation in the detected value. (Seki, T.)

  2. Alternative Fuels Data Center: How Do Hybrid Electric Cars Work?

    Science.gov (United States)

    battery is engaged and also powers vehicle accessories. DC/DC converter: This device converts higher -voltage DC power from the traction battery pack to the lower-voltage DC power needed to run vehicle generators that perform both the drive and regeneration functions. Electric traction motor: Using power from

  3. Driving While Interacting With Google Glass: Investigating the Combined Effect of Head-Up Display and Hands-Free Input on Driving Safety and Multitask Performance.

    Science.gov (United States)

    Tippey, Kathryn G; Sivaraj, Elayaraj; Ferris, Thomas K

    2017-06-01

    This study evaluated the individual and combined effects of voice (vs. manual) input and head-up (vs. head-down) display in a driving and device interaction task. Advances in wearable technology offer new possibilities for in-vehicle interaction but also present new challenges for managing driver attention and regulating device usage in vehicles. This research investigated how driving performance is affected by interface characteristics of devices used for concurrent secondary tasks. A positive impact on driving performance was expected when devices included voice-to-text functionality (reducing demand for visual and manual resources) and a head-up display (HUD) (supporting greater visibility of the driving environment). Driver behavior and performance was compared in a texting-while-driving task set during a driving simulation. The texting task was completed with and without voice-to-text using a smartphone and with voice-to-text using Google Glass's HUD. Driving task performance degraded with the addition of the secondary texting task. However, voice-to-text input supported relatively better performance in both driving and texting tasks compared to using manual entry. HUD functionality further improved driving performance compared to conditions using a smartphone and often was not significantly worse than performance without the texting task. This study suggests that despite the performance costs of texting-while-driving, voice input methods improve performance over manual entry, and head-up displays may further extend those performance benefits. This study can inform designers and potential users of wearable technologies as well as policymakers tasked with regulating the use of these technologies while driving.

  4. Postsplenectomy recurrence of idiopathic thrombocitopenic purpura: role of laparoscopic splenectomy in the treatment of accessory spleen.

    Science.gov (United States)

    Leo, C A; Pravisani, R; Bidinost, S; Baccarani, U; Bresadola, V; Risaliti, A; Terrosu, G

    2015-01-01

    Idiopatic thrombocytopenic purpura (ITP) is the most common indication for splenectomy. The failure rate of surgery is about 8% and the failure rate after splenectomy is approximately 28% for all patients. When the presence of an accessory spleen is diagnosed, splenectomy is recommended. Laparoscopic approach is considered the first choice. At our Department, between July and November 2011 two patients underwent laparoscopic accessory splenectomy for recurrence of ITP. Both patients had a previously laparoscopic splenectomy. Preoperative Magnetic Resonance (MR) was performed in both the cases revealing the presence of an accessory spleen. The operative time was 105 and 100 minutes respectively. No perioperative complications occured. Hospital stay was four days in both cases. The first patient had a disease free period of two months; the second one of one month. Both patients restarted immunosuppressive therapy. The relapse of thrombocytopenia post-splenectomy can be associated with the presence of an accessory spleen. The laparoscopic accessory splenectomy should be considered the first choice approach. Surgical accessory splenectomy allows a transitory remission of the disease.

  5. Role of nuclear medicine imaging in differential diagnosis of accessory spleens in patients after splenectomy

    International Nuclear Information System (INIS)

    D’Amico, Andrea; Cofalik, Anna; Przeorek, Cesary; Gawlik, Tomasz; Olczyk, Tomasz; Kalemba, Michał; Modorowska, Alicja; Turska-d’Amico, Maria; Bobek-Billewicz, Barbara; Jarzab, Barbara

    2012-01-01

    More than 10% of healthy population has one or more accessory spleens. The most common location is the hilum of the spleen or area near the tail of the pancreas. The radiological appearance of accessory spleens in oncologic patients who underwent splenectomy can be misinterpreted as a recurrence, especially in the case of compensatory growth of an accessory spleen in successive radiological examinations. We present the cases of three patients who underwent splenectomy for gastric carcinoid, gastric adenocarcinoma and cancer of the left adrenal gland, respectively. CT examination and/or PET-CT scan revealed suspicious findings in the left upper abdomen. In one patient, the dimensional increase of this finding in successive examinations was initially considered suggestive for cancer recurrence. Scintigraphy with 99m Tc-nanocolloid was able to confirm the presence of an accessory spleen in all these patients. Splenic scintigraphy is an economical, accessible and accurate tool in differential diagnosis of accessory spleens in patients after splenectomy

  6. Pre-excitation pattern associated with accessory pathway related tachycardia: Case report

    Directory of Open Access Journals (Sweden)

    Burazor Mirko

    2010-01-01

    Full Text Available Introduction. Pre-excitation is based on an accessory conduction pathway between the atrium and ventricle. The term Wolff- Parkinson-White (WPW syndrome is used for patients with the pre-excitation/WPW pattern associated with AP-related tachycardia. Case Outline. We present a 52-year-old man with severe palpitation, fatigue, lightheadedness and difficulty breathing. The initial ECG showed tachyarrhythmia with heart rate between 240 and 300/min. He was treated with antiarrhythmics (Digitalis, Verapamil, Lidocaine with no response. Then, the patient was treated with electrical cardioversion and was referred to our Clinic for further evaluation with the diagnosis: “Ventricular tachycardia”. During in-hospital stay, the previously undiagnosed WPW pattern had been seen. Additional diagnostic tests confirmed permanent pre-excitacion pattern (ECG Holter recording, exercises test. The patient was referred to an electrophysiologist for further evaluation. Mapping techniques provided an accurate assessment of the position of the accessory pathway which was left lateral. The elimination of the accessory pathway by radiofrequent catheter ablation is highly effective in termination and elimination of tacchyarrhythmias. Conclusion. Symptomatic, life-threatening arrhythmia, first considered as ventricular tachycardia, reflected atrial fibrillation with ventricular pre-excitation over an accessory pathway in a patient with previously undiagnosed WPW syndrome.

  7. Phase II CRADA ORNL99-0568 Report : Developing Transmission-Less Inverter Drive Systems for Axial-Gap Permanent magnet Accessory and Traction Motors and Generators; FINAL

    International Nuclear Information System (INIS)

    McKeever, J.W.

    2001-01-01

    Researchers of the Oak Ridge National Laboratory's (ORNLs) Power Electronics and Electric Machine Research Center (PEEMRC) collaborated with Visual Computing Systems (VCS) to develop an electric axial-gap permanent magnet (PM) motor controlled by a self-sensing inverter for driving vehicle accessories such as power steering, air conditioning, and brakes. VCS designed an 8 kW motor based on their Segmented Electromagnetic Array (SEMA) technology. ORNL designed a 10 kW inverter to fit within the volume of a housing, which had been integrated with the motor. This modular design was pursued so that multiple modules could be used for higher power applications. ORNL built the first inverter under the cooperative research and development agreement (CRADA) ORNL 98-0514 and drove a refurbished Delta motor with no load during the Merit Review at ORNL on Monday, May 17, 1999. Inverter circuitry and instructions for assembling the inverters were sent to VCS. A report was prepared and delivered during the Future Car Congress in April 2000, at Arlington, Virginia. Collaboration continued under CRADA ORNL 99-0568 as VCS designed and built a SEMA motor with a dual coil platter to be the traction motor for an electric truck. VCS and ORNL assembled two 45 kW inverters. Each inverter drove one coil, which was designed to deliver 15 kW continuous power and 45 kW peak power for 90 s. The vehicle was road tested as part of the Future Truck Competition. A report was prepared and delivered during the PCIM in October 2000, at Boston, Massachusetts

  8. Accessories for detention and protection used in small animals radiation therapy

    International Nuclear Information System (INIS)

    Vettorato, Michel Campos; Vulcano, Luiz Carlos; Fernandes, Marco Antonio Rodrigues

    2016-01-01

    Radiation therapy is a medical method well established in the treatment of cancer in veterinary medicine worldwide. The radiotherapy protocols applied in animals vary according to several factors. In most procedures require sedation or anesthesia of the animal and this fact imposes the use of immobilization accessories specially developed for the different species of animals and treated as their specified procedures. Therefore, this study aims to describe the types of accessories used for immobilization and for the protection of small animals undergoing radiotherapy. For its development a literature search was performed by search sites like Google Scholar, Scielo, Bireme, PubMed, and consultations in books campus library Botucatu UNESP. Despite the limitations of each accessory rated this review, it was possible to identify the use of each and how this can be advantageous for the treatment of animals undergoing radiation therapy. (author)

  9. Successful catheter ablation of a left anterior accessory pathway from the non-coronary cusp of the aortic valve.

    Science.gov (United States)

    Laranjo, Sérgio; Oliveira, Mário; Trigo, Conceição

    2015-08-01

    Left anterior accessory pathways are considered to be rare findings. Catheter ablation of accessory pathways in this location remains a challenging target, and few reports about successful ablation of these accessory pathways are available. We describe our experience regarding a case of a manifest left anterior accessory pathway ablation using radiofrequency energy at the junction of the left coronary cusp with the non-coronary cusp.

  10. Partial discharge testing of in-situ power cable accessories

    Energy Technology Data Exchange (ETDEWEB)

    Orban, H. E.

    2002-07-01

    An overview of commercially available diagnostic methods for in-situ power cable accessories is given and relevant field experiences with these diagnostics are described. The discussion includes both PILC and polymeric insulated cables. Two major types of degradation are most frequently involved in cable systems. One is an overall condition caused by chemical aging and /or water treeing. Diagnostics for this type of aging include dissipation factor (loss angle), harmonic analysis, return voltage, isothermal relaxation current, dielectric response, or dc leakage current. The second type of degradation is discrete or incremental; condition assessment utilizes dissipation factor measurements or partial discharge (PD) level measurements. The focus in this paper is on PD diagnostics, especially off-line methods such as the 60 Hz test, the combined AC and VLF diagnostic, and the oscillating wave test system test. Among on-line diagnostics, ultrasonic detection of partial discharge and measurement of partial discharge by installing direct, capacitive or inductive couplers near cable accessories, are described. Overall, partial discharge detection and location in cable accessories is considered inadequate, since interpretation of results is difficult due to the number of variables involved. 28 refs., 1 tab.

  11. Accessory minerals of Permian volcanites of South Gemeric Unit and Borka Nappe

    Energy Technology Data Exchange (ETDEWEB)

    Smelko, M; Vozarova, A [Comenius University in Bratislava, Faculty of Natural Sciences, Department of Mineralogy and Petrology, 84215 Bratislava (Slovakia)

    2010-04-28

    The goal of this study was to summarize and complete the results from the study of metavolcanites and their accessory minerals (Zircon Zr{sub 2}SiO{sub 4}, Monazite CePO{sub 4} and Xenotime YPO{sub 4}) from the Southern Gemericum Unit and from the Borka Nappe. The acid metavolcanites and their accessory minerals were observed of the modern analytical methods.

  12. Smartphone Based Approach For Monitoring Inefficient And Unsafe Driving Behavior And Recognizing Drink And Drive Conditions.

    Directory of Open Access Journals (Sweden)

    G. V. Mane

    2015-08-01

    Full Text Available Many automobile drivers having knowledge of the driving behaviours and habits that can lead to inefficient and unsafe driving. However it is often the case that these same drivers unknowingly manifest these inefficient and unsafe driving behaviours in their everyday driving activity. The proposed system proposes a practical and economical way to capture measure and alert drives of inefficient and unsafe driving as well as highly efficient system aimed at early detection and alert of dangerous vehicle maneuvers typically related to drunk driving. The upcoming solution consists of a mobile application running on a modern smartphone device paired with a compatible OBDII On-board diagnostics II reader.

  13. Proteomic identification of Drosophila melanogaster male accessory gland proteins, including a pro-cathepsin and a soluble γ-glutamyl transpeptidase

    Directory of Open Access Journals (Sweden)

    Sajid Mohammed

    2006-05-01

    Full Text Available Background In Drosophila melanogaster, the male seminal fluid contains proteins that are important for reproductive success. Many of these proteins are synthesised by the male accessory glands and are secreted into the accessory gland lumen, where they are stored until required. Previous studies on the identification of Drosophila accessory gland products have largely focused on characterisation of male-specific accessory gland cDNAs from D. melanogaster and, more recently, Drosophila simulans. In the present study, we have used a proteomics approach without any sex bias to identify proteins in D. melanogaster accessory gland secretions. Results Thirteen secreted accessory gland proteins, including seven new accessory gland proteins, were identified by 2D-gel electrophoresis combined with mass spectrometry of tryptic fragments. They included protein-folding and stress-response proteins, a hormone, a lipase, a serpin, a cysteine-rich protein and two peptidases, a pro-enzyme form of a cathepsin K-like cysteine peptidase and a γ-glutamyl transpeptidase. Enzymatic studies established that accessory gland secretions contain a cysteine peptidase zymogen that can be activated at low pH. This peptidase may have a role in the processing of female and other male-derived proteins, but is unlikely to be involved in the processing of the sex peptide. γ-Glutamyl transpeptidases are type II integral membrane proteins; however, the identified AG γ-glutamyl transpeptidase (GGT-1 is unusual in that it is predicted to be a soluble secreted protein, a prediction that is supported by biochemical evidence. GGT-1 is possibly involved in maintaining a protective redox environment for sperm. The strong γ-glutamyl transpeptidase activity found in the secretions provides an explanation for the observation that glutamic acid is the most abundant free amino acid in accessory gland secretions of D. melanogaster. Conclusion We have applied biochemical approaches, not used

  14. Proteomic identification of Drosophila melanogaster male accessory gland proteins, including a pro-cathepsin and a soluble gamma-glutamyl transpeptidase.

    Science.gov (United States)

    Walker, Michael J; Rylett, Caroline M; Keen, Jeff N; Audsley, Neil; Sajid, Mohammed; Shirras, Alan D; Isaac, R Elwyn

    2006-05-02

    In Drosophila melanogaster, the male seminal fluid contains proteins that are important for reproductive success. Many of these proteins are synthesised by the male accessory glands and are secreted into the accessory gland lumen, where they are stored until required. Previous studies on the identification of Drosophila accessory gland products have largely focused on characterisation of male-specific accessory gland cDNAs from D. melanogaster and, more recently, Drosophila simulans. In the present study, we have used a proteomics approach without any sex bias to identify proteins in D. melanogaster accessory gland secretions. Thirteen secreted accessory gland proteins, including seven new accessory gland proteins, were identified by 2D-gel electrophoresis combined with mass spectrometry of tryptic fragments. They included protein-folding and stress-response proteins, a hormone, a lipase, a serpin, a cysteine-rich protein and two peptidases, a pro-enzyme form of a cathepsin K-like cysteine peptidase and a gamma-glutamyl transpeptidase. Enzymatic studies established that accessory gland secretions contain a cysteine peptidase zymogen that can be activated at low pH. This peptidase may have a role in the processing of female and other male-derived proteins, but is unlikely to be involved in the processing of the sex peptide. gamma-Glutamyl transpeptidases are type II integral membrane proteins; however, the identified AG gamma-glutamyl transpeptidase (GGT-1) is unusual in that it is predicted to be a soluble secreted protein, a prediction that is supported by biochemical evidence. GGT-1 is possibly involved in maintaining a protective redox environment for sperm. The strong gamma-glutamyl transpeptidase activity found in the secretions provides an explanation for the observation that glutamic acid is the most abundant free amino acid in accessory gland secretions of D. melanogaster. We have applied biochemical approaches, not used previously, to characterise

  15. Fast wave current drive

    International Nuclear Information System (INIS)

    Goree, J.; Ono, M.; Colestock, P.; Horton, R.; McNeill, D.; Park, H.

    1985-07-01

    Fast wave current drive is demonstrated in the Princeton ACT-I toroidal device. The fast Alfven wave, in the range of high ion-cyclotron harmonics, produced 40 A of current from 1 kW of rf power coupled into the plasma by fast wave loop antenna. This wave excites a steady current by damping on the energetic tail of the electron distribution function in the same way as lower-hybrid current drive, except that fast wave current drive is appropriate for higher plasma densities

  16. Automatic car driving detection using raw accelerometry data.

    Science.gov (United States)

    Strączkiewicz, M; Urbanek, J K; Fadel, W F; Crainiceanu, C M; Harezlak, J

    2016-09-21

    Measuring physical activity using wearable devices has become increasingly popular. Raw data collected from such devices is usually summarized as 'activity counts', which combine information of human activity with environmental vibrations. Driving is a major sedentary activity that artificially increases the activity counts due to various car and body vibrations that are not connected to human movement. Thus, it has become increasingly important to identify periods of driving and quantify the bias induced by driving in activity counts. To address these problems, we propose a detection algorithm of driving via accelerometry (DADA), designed to detect time periods when an individual is driving a car. DADA is based on detection of vibrations generated by a moving vehicle and recorded by an accelerometer. The methodological approach is based on short-time Fourier transform (STFT) applied to the raw accelerometry data and identifies and focuses on frequency vibration ranges that are specific to car driving. We test the performance of DADA on data collected using wrist-worn ActiGraph devices in a controlled experiment conducted on 24 subjects. The median area under the receiver-operating characteristic curve (AUC) for predicting driving periods was 0.94, indicating an excellent performance of the algorithm. We also quantify the size of the bias induced by driving and obtain that per unit of time the activity counts generated by driving are, on average, 16% of the average activity counts generated during walking.

  17. 21 CFR 864.3600 - Microscopes and accessories.

    Science.gov (United States)

    2010-04-01

    ... enlarge images of specimens, preparations, and cultures for medical purposes. Variations of microscopes... light. (3) Inverted stage microscopes, which permit examination of tissue cultures or other biological... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Microscopes and accessories. 864.3600 Section 864...

  18. 21 CFR 884.6120 - Assisted reproduction accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction accessories. 884.6120 Section 884.6120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., and maintain gametes and/or embryos at an appropriate freezing temperature. (b) Classification. Class...

  19. A qualitative exploration of driving stress and driving discourtesy.

    Science.gov (United States)

    Scott-Parker, B; Jones, C M; Rune, K; Tucker, J

    2018-05-31

    Driving courtesy, and conversely driving discourtesy, recently has been of great interest in the public domain. In addition, there has been increasing recognition of the negative impact of stress upon the individual's health and wellbeing, with a plethora of interventions aimed at minimising stress more generally. The research literature regarding driving dis/courtesy, in comparison, is scant, with a handful of studies examining the dis/courteous driving behaviour of road users, and the relationship between driving discourtesy and driving stress. To examine courteous and discourteous driving experiences, and to explore the impact of stress associated with such driving experiences. Thirty-eight drivers (20 females) from the Sunshine Coast region volunteered to participate in one of four 1-1.5 h focus groups. Content analysis used the verbatim utterances captured via an Mp3 device. Three themes pertaining to stressful and discourteous interactions were identified. Theme one pertained to the driving context: road infrastructure (eg, roundabouts, roadwork), vehicles (eg, features), location (eg, country vs city, unfamiliar areas), and temporal aspects (eg, holidays). Theme two pertained to other road users: their behaviour (eg, tailgating, merging), and unknown factors (eg, illicit and licit drug use). Theme three pertained to the self as road user: their own behaviours (eg, deliberate intimidation), and their emotions (eg, angry reaction to other drivers, being in control). Driving dis/courtesy and driving stress is a complex phenomenon, suggesting complex intervention efforts are required. Driving discourtesy was reported as being highly stressful, therefore intervention efforts which encourage driving courtesy and which foster emotional capacity to cope with stressful circumstances appear warranted. Copyright © 2018. Published by Elsevier Ltd.

  20. 49 CFR 390.17 - Additional equipment and accessories.

    Science.gov (United States)

    2010-10-01

    ... equipment and accessories, not inconsistent with or prohibited by this subchapter, provided such equipment... are used. [53 FR 18052, May 19, 1988, as amended at 60 FR 38744, July 28, 1995. Redesignated at 65 FR...

  1. Male accessory gland secretory protein polymorphism in natural ...

    Indian Academy of Sciences (India)

    [Ravi Ram K. and Ramesh S. R. 2007 Male accessory gland secretory protein polymorphism in natural ..... quence of species-specific genetic responses to variations in .... Eberhard W. G. 1996 Female control: sexual selection by cryptic.

  2. Design of a marine sediment trap and accessories

    Digital Repository Service at National Institute of Oceanography (India)

    Janakiraman, G.; Fernando, V.; Venkatesan, R.; Rajaraman, V.S.

    The marine sediment trap and the mooring accessories were developed indigenously and were used successfully for the collection of settling sediments in the Arabian Sea The experience gained in using sediment trap and further improvements...

  3. Accessory tragus: a dentist's perspective

    OpenAIRE

    Khandelwal, Vishal; Banda, Naveen Reddy; Nayak, Ullal Anand; Banda, Vanaja Reddy

    2013-01-01

    Accessory tragus (AT) also referred as preauricular tag is a rudimentary tag of ear tissue This paper presents two specific cases: one hereditary and another sporadic case of AT. A general clinical description of AT, its associated syndromes, embryology aetiopathogenesis and management is discussed. A dentist can play an important role in spotting the AT during their head and neck examination. The presence of this defect can be correlated to other congenital defects of first branchial arch. O...

  4. Accessory left atrial diverticulae: contractile properties depicted with 64-slice cine-cardiac CT.

    LENUS (Irish Health Repository)

    Killeen, Ronan P

    2012-02-01

    To assess the contractility of accessory left atrial appendages (LAAs) using multiphasic cardiac CT. We retrospectively analyzed the presence, location, size and contractile properties of accessory LAAs using multiphasic cardiac 64-slice CT in 102 consecutive patients (63 males, 39 females, mean age 57). Multiplanar reformats were used to create image planes in axial oblique, sagittal oblique and coronal oblique planes. For all appendages with an orifice diameter >or= 10 mm, axial and sagittal diameters and appendage volumes were recorded in atrial diastole and systole. Regression analysis was performed to assess which imaging appearances best predicted accessory appendage contractility. Twenty-three (23%) patients demonstrated an accessory LAA, all identified along the anterior LA wall. Dimensions for axial oblique (AOD) and sagittal oblique (SOD) diameters and sagittal oblique length (SOL) were 6.3-19, 3.4-20 and 5-21 mm, respectively. All appendages (>or=10 mm) demonstrated significant contraction during atrial systole (greatest diameter reduction was AOD [3.8 mm, 27%]). Significant correlations were noted between AOD-contraction and AOD (R = 0.57, P < 0.05) and SOD-contraction and AOD, SOD and SOL (R = 0.6, P < 0.05). Mean diverticulum volume in atrial diastole was 468.4 +\\/- 493 mm(3) and in systole was 171.2 +\\/- 122 mm(3), indicating a mean change in volume of 297.2 +\\/- 390 mm(3), P < 0.0001. Stepwise multiple regression analysis revealed SOL to be the strongest independent predictor of appendage contractility (R(2) = 0.86, P < 0.0001) followed by SOD (R(2) = 0.91, P < 0.0001). Accessory LAAs show significant contractile properties on cardiac CT. Those accessory LAAs with a large sagittal height or depth should be evaluated for contractile properties, and if present should be examined for ectopic activity during electrophysiological studies.

  5. An epidermoid cyst of accessory spleen simulating tumors of the tail of pancreas

    Directory of Open Access Journals (Sweden)

    Amit Kumar Sinha

    2015-07-01

    Full Text Available An epidermoid cyst of accessory spleen, a rare condition may present as pseudocyst of pancreas and other cystic tumors of the pancreas. This case report along with the review of literature attributes some clinical features and investigative pattern to differentiate between epidermoid cyst of accessory spleen and other cystic tumor of pancreas.

  6. A novel method of lengthening the accessory nerve for direct coaptation during nerve repair and nerve transfer procedures.

    Science.gov (United States)

    Tubbs, R Shane; Maldonado, Andrés A; Stoves, Yolanda; Fries, Fabian N; Li, Rong; Loukas, Marios; Oskouian, Rod J; Spinner, Robert J

    2018-01-01

    OBJECTIVE The accessory nerve is frequently repaired or used for nerve transfer. The length of accessory nerve available is often insufficient or marginal (under tension) for allowing direct coaptation during nerve repair or nerve transfer (neurotization), necessitating an interpositional graft. An attractive maneuver would facilitate lengthening of the accessory nerve for direct coaptation. The aim of the present study was to identify an anatomical method for such lengthening. METHODS In 20 adult cadavers, the C-2 or C-3 connections to the accessory nerve were identified medial to the sternocleidomastoid (SCM) muscle and the anatomy of the accessory nerve/cervical nerve fibers within the SCM was documented. The cervical nerve connections were cut. Lengths of the accessory nerve were measured. Samples of the cut C-2 and C-3 nerves were examined using immunohistochemistry. RESULTS The anatomy and adjacent neural connections within the SCM are complicated. However, after the accessory nerve was "detethered" from within the SCM and following transection, the additional length of the accessory nerve increased from a mean of 6 cm to a mean of 10.5 cm (increase of 4.5 cm) after cutting the C-2 connections, and from a mean of 6 cm to a mean length of 9 cm (increase of 3.5 cm) after cutting the C-3 connections. The additional length of accessory nerve even allowed direct repair of an infraclavicular target (i.e., the proximal musculocutaneous nerve). The cervical nerve connections were shown not to contain motor fibers. CONCLUSIONS An additional length of the accessory nerve made available in the posterior cervical triangle can facilitate direct repair or neurotization procedures, thus eliminating the need for an interpositional nerve graft, decreasing the time/distance for regeneration and potentially improving clinical outcomes.

  7. Control-rod driving mechanism

    International Nuclear Information System (INIS)

    Jodoi, Takashi.

    1976-01-01

    Purpose: To prevent falling of control rods due to malfunction. Constitution: The device of the present invention has a scram function in particular, and uses principally a fluid pressure as a scram accelerating means. The control rod is held by upper and lower holding devices, which are connected by a connecting mechanism. This connecting mechanism is designed to be detachable only at the lower limit of driving stroke of the control rod so that there occurs no erroneous scram resulting from careless disconnection of the connecting mechanism. Further, scramming operation due to own weight of the scram operating portion such as control rod driving shaft may be effected to increase freedom. (Kamimura, M.)

  8. Incidence and morphology of accessory heads of flexor pollicis longus and flexor digitorum profundus (Gantzer's muscles)

    Science.gov (United States)

    JONES, M.; ABRAHAMS, P. H.; SAÑUDO, J. R.; CAMPILLO, M.

    1997-01-01

    In 1813 Gantzer described 2 accessory muscles in the human forearm which bear his name (Wood, 1868; Macalister, 1875; Testut, 1884; Le Double, 1897). The more frequent of the 2 accessory muscles or ‘accessorius ad pollicem’ was found to arise from the coronoid process of the ulna, coursing distally to attach into the flexor pollicis longus muscle (flexor pollicis longus accessory head, FPLah). The less frequently observed or ‘accessorius ad flexorem profundum digitorum’ was again found to arise from the coronoid process and course to join into the flexor digitorum profundus (flexor digitorum profundus accessory head, FDPah). Since their initial description, they have been examined in further detail by a number of authors (Wood, 1868; Macalister, 1875; Le Double, 1897; Dykes & Anson, 1944; Mangini, 1960; Malhotra et al. 1982; Dellon & McKinnon, 1987; Kida, 1988). These studies, most of them focusing on the FPLah, all show different results of prevalence, origin, insertion, relations and nerve supply. We undertook this study with the aim of providing a more accurate account of the detailed morphology of both accessory muscles because of the above-mentioned inconsistent anatomical descriptions and the lack of information as to important aspects such as vascular supply, morphology (shape and length) and the coexistence of both accessory heads. PMID:9419002

  9. Accessories modifying based on plastic waste of shampoo bottle as home economic product

    Science.gov (United States)

    Setyowati, Erna; Sukesi, Siti

    2018-03-01

    Plastic is a waste that can not decompose by the soil and if its left without a good handling can pollute the environment. Plastic waste needs processing by the recycle bottles principle. Shampoo bottle is one of plastic waste with high density polyethylene type (HDPE). One of the innovation to recycling shampoo bottles waste into the new products whichbeneficially and aestheticallyform by engineered the buns accesories. Accessories are one of the tools used by most women, in the form of trinkets or ornaments which ajusted to the trend to beautify the look. Accessories from shampoo bottle waste can be obtained from household waste, beauty salon and the beauty program study by inculcating human beings' behavior by transforming waste into blessing while also increasing family income. Technique of making its by compiling through improvement of panelist team. The goal of this research is to engineering theaccessories based on shampoo bottle waste as home economics. The method are using experiment, observation and documentation, analysis using descriptive. The results obtained from the overall sensory test averaged at 93%, while the favored test averaged at 85.5%. The product can be ordered according to the desired design, but it takes a long time. Therefore accessories engineering from shampoo bottles waste-based can be used as home economics. The production of shampoo bottles waste-based accessories should improved its quality and quantity, to be marketed through the community, by the cooperation with accessories and bun craftsmen.

  10. 21 CFR 886.1930 - Tonometer and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tonometer and accessories. 886.1930 Section 886.1930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... type) or to measure intraocular tension by applanation (applying a small flat disk to the cornea...

  11. Accessory caudal axial and pelvic ribs

    International Nuclear Information System (INIS)

    Bohutova, J.; Kolar, J.; Vitovec, J.; Vyhnanek, L.

    1980-01-01

    Accessory caudal ribs are reported as an extremely curious anomaly in five patients. Once the fracture of this rib was a source of pains after injury. The different shapes of the ribs are documented in this clinical survey which is the most extensive in the present literature. Anomalous ribs arise due to inappropriate segmentation during the embryonal development of the axial skeleton. (orig.) [de

  12. Progress in the clinical imaging research of bone diseases on ankle and foot sesamoid bones and accessory ossicles

    Science.gov (United States)

    Li, Xiaozhong; Shi, Lenian; Liu, Taiyun; Wang, Lin

    2012-01-01

    Summary Sesamoid bones and accessory ossicles are research focuses of foot and ankle surgery. Pains of the foot and ankle are related to sesamoid bones and accessory ossicles. The specific anatomical and functional relationship of sesamoid bones and accessory ossicles can cause such bone diseases as the dislocation of sesamoid bones and accessory bones, infection, inflammation and necrosis of sesamoid bones, cartilage softening, tenosynovitis of sesamoid bones and the sesamoid bone syndrome. However, these bone diseases are often misdiagnosed or mistreated. In patients with trauma history, relevant diseases of sesamoid bones and accessory ossicles as above mentioned are highly probable to be misdiagnosed as avulsion fractures. In such cases, radiographic findings may provide a basis for clinical diagnosis. PMID:25343083

  13. A computational model for lower hybrid current drive

    International Nuclear Information System (INIS)

    Englade, R.C.; Bonoli, P.T.; Porkolab, M.

    1983-01-01

    A detailed simulation model for lower hybrid (LH) current drive in toroidal devices is discussed. This model accounts reasonably well for the magnitude of radio frequency (RF) current observed in the PLT and Alcator C devices. It also reproduces the experimental dependencies of RF current generation on toroidal magnetic field and has provided insights about mechanisms which may underlie the observed density limit of current drive. (author)

  14. Special Considerations in Distracted Driving with Teens

    Science.gov (United States)

    Durbin, Dennis R; McGehee, Daniel V; Fisher, Donald; McCartt, Anne

    2014-01-01

    Novice teen drivers have long been known to have an increased risk of crashing, as well as increased tendencies toward unsafe and risky driving behaviors. Teens are unique as drivers for several reasons, many of which have implications specifically in the area of distracted driving. This paper reviews several of these features, including the widespread prevalence of mobile device use by teens, their lack of driving experience, the influence of peer passengers as a source of distraction, the role of parents in influencing teens’ attitudes and behaviors relevant to distracted driving and the impact of laws designed to prevent mobile device use by teen drivers. Recommendations for future research include understanding how engagement in a variety of secondary tasks by teen drivers affects their driving performance or crash risk; understanding the respective roles of parents, peers and technology in influencing teen driver behavior; and evaluating the impact of public policy on mitigating teen crash risk related to driver distraction. PMID:24776228

  15. Formation of accessory mineral bed layers during erosion of bentonite buffer material

    International Nuclear Information System (INIS)

    Schatz, Timothy; Kanerva, Noora

    2012-01-01

    Document available in extended abstract form only. dilute groundwater at a transmissive fracture interface, accessory phases within bentonite, such as quartz, feldspar, etc., might remain behind and form a filter bed or cake. As more and more montmorillonite is lost, the thickness of the accessory mineral bed increases and the continued transport of montmorillonite slows and possibly stops if the porosity of the filter bed is sufficiently compressed. Alternatively or concurrently, as the accessory mineral filter bed retains montmorillonite colloids, a filter cake composed of montmorillonite itself may be formed. Ultimately, depending on their extent, properties, and durability, such processes may provide the bentonite buffer system with an inherent, self-filtration mechanism which serves to limit the effects of colloidal erosion. A conceptual view of bentonite buffer extrusion and erosion in an intersecting fracture with formation of an accessory mineral filter bed and montmorillonite filter cake is presented in Figure 1. Due to the swelling pressure of the bentonite buffer, the situation described in Figure 1 may be analogous to that of the case of pressure filtration where a filter cake is formed by pressing a suspension through a filter medium and, by a mechanism known as expression, the filter cake is compressed by direct contact with a solid surface resulting in a reduction of its porosity. In order to examine whether the erosion of bentonite material through contact with dilute groundwater at a transmissive fracture interface could intrinsically result in 1) the formation of an accessory mineral filter bed and cake and/or 2) filter caking of montmorillonite itself, a series of laboratory tests were performed in a flow-through, horizontal, 1 mm aperture, artificial fracture system. Bentonite buffer material was simulated by using mixtures (75/25 weight percent ratio) of purified sodium montmorillonite and various additives serving as accessory mineral proxies

  16. Electromagnetic brake/clutch device

    Science.gov (United States)

    Vranish, John M. (Inventor)

    1994-01-01

    An electromagnetic brake/clutch device includes a drive shaft supported by at least one bearing for transmitting torque, a housing, affixed to prevent its rotation, surrounding the drive shaft, and an electromagnetically activated device within the housing to selectively prevent and allow rotation of the drive shaft. The electromagnetically activated device includes a plurality of cammed rollers to prevent counter-clockwise rotation of the drive shaft. The drive shaft includes a circumferential disk and the housing includes a reaction ring for engagement with the plurality of cammed rollers. The plurality of cammed rollers are released from engagement with the circumferential disk and the reaction ring by a plurality of tripping mechanisms within the housing. The tripping action uses the locking force to act as a release force merely by changing the boundary conditions of the roller interface angles. The tripping mechanisms include trippers for disengaging the plurality of cammed rollers and an anvil shaped portion for providing lateral movement of the trippers. The plurality of cammed rollers is preloaded to engagement with the circumferential disk and reaction ring by a spring, and is located with respect to an adjacent tripping mechanism with another spring.

  17. Scintigraphic diagnosis and computed tomographic localization of an accessory spleen following relapse of chronic immune thrombocytopaenia

    International Nuclear Information System (INIS)

    Cardaci, G.T.; Blake, M.P.

    1992-01-01

    Chronic immune thrombocytopaenia is an immunologically mediated disorder resulting in disordered platelet kinetics and potentially life-threatening disease. Failure of medical therapy is an indication for splenectomy, and responses are seen in 80% of patients following this procedure. An important cause of relapse following splenectomy is the presence of an accessory spleen. A patient with Hodgkin's Disease developed chronic immune thrombocytopaenia despite previous splenectomy. A remission was induced with immunosuppressive therapy, but he later relapsed. An accessory spleen was detected using 99 m Tc denatured red blood cells and localized using computed tomography. Resection of the accessory spleen resulted in clinical remission. As accessory spleens are often small in size, combined modality imaging is recommended in the evaluation of this disorder. 15 refs., 2 figs

  18. Working principle and structure characteristics analysis of the reactivity control drive mechanism

    International Nuclear Information System (INIS)

    Zhao Tianyu; Huang Zhiyong; Chen Feng; He Xuedong

    2010-01-01

    The startup, power regulation and safety shutdown of the nuclear reactor are operated by the reactivity control devices. Reactivity control drive mechanism is a key mechanical transmission component, which directly control the location of the neutron absorber in the core. Its working condition is complex, and its service life should be long., which requires high reliability. PWR as well as newly developed different type of reactors have different control devices drive mechanism. This paper mainly do analysis and comparison about the working environment, mechanical transmission principle, structure, performance, service life and other aspects of PWR, HTR control devices drive mechanism. In addition, this paper is also based on the working principles of reactive control devices drive mechanism, also consider the trends of its design and test verification by the international countries, and discussed the method and feasibility of improving and perfecting the structure and function of drive mechanism. (authors)

  19. Three-dimensional finite element analysis on canine teeth distalization by different accessories of bracket-free invisible orthodontics technology

    Science.gov (United States)

    Xu, Nuo; Lei, Xue; Yang, Xiaoli; Li, Xinhui; Ge, Zhenlin

    2018-04-01

    Objective: to compare canine tooth stress distribution condition during maxillary canine tooth distalization by different accessories of bracket-free invisible orthodontics technology after removal of maxillary first premolar, and provide basis for clinical design of invisible orthodontics technology. Method: CBCT scanning image of a patient with individual normal occlusion was adopted, Mimics, Geomagic and ProlE software were used for establishing three-dimensional models of maxilla, maxillary dentition, parodontium, invisible orthodontics appliance and accessories, ANSYS WORKBENCH was utilized as finite element analysis tools for analyzing stress distribution and movement pattern of canine tooth and parodontium when canine tooth was equipped with power arm and vertical rectangle accessory. Meanwhile, canine tooth none-accessory design group was regarded as a control. Result: teeth had even bistal surface stress distribution in the power arm group; stress was concentrated on distal tooth neck, and the stress was gradually deviated to mesial-labial side and distal lingual side in vertical rectangle group and none-accessory group. Conclusion: teeth tend to move as a whole in the Power arm group, vertical rectangle group has lower tooth gradient compared with the none-accessory group, teeth are inclined for movement in the none-accessory group, and canine teeth tend to rotate to the distal lingual side.

  20. MR imaging findings of painful type II accessory navicular bone: correlation with surgical and pathologic studies

    International Nuclear Information System (INIS)

    Choi, Yun Sun; Lee, Kyung Tai; Kim, Eun Kyung; Kang, Heung Sik

    2004-01-01

    To evaluate the MR imaging findings of painful type II accessory navicular bone and to correlate these with the surgical and pathologic findings. The MR images of 17 patients with medial foot pain and surgically proven type II accessory navicular abnormalities were reviewed. The changes of signal intensity in the accessory navicular, synchondrosis and adjacent soft tissue, the presence of synchondrosis widening, and posterior tibial tendon (PTT) pathology on the T1-weighted and fat-suppressed T2-weighted images were analyzed. The MR imaging findings were compared with the surgical and pathologic findings. The fat-suppressed T2-weighted images showed high signal intensity in the accessory navicular bones and synchondroses in all patients, and in the soft tissue in 11 (64.7%) of the 17 patients, as well as synchondrosis widening in 3 (17.6%) of the 17 patients. The MR images showed tendon pathology in 12 (75%) of the 16 patients with PTT dysfunction at surgery. The pathologic findings of 16 surgical specimens included areas of osteonecrosis with granulomatous inflammation, fibrosis and destruction of the cartilage cap. The MR imaging findings of painful type II accessory navicular bone are a persistent edema pattern in the accessory navicular bone and within the synchondrosis, indicating osteonecrosis, inflammation and destruction of the cartilage cap. Posterior tibial tendon dysfunction was clinically evident in most patients

  1. Safe driving in a green world: a review of driver performance benchmarks and technologies to support 'smart' driving.

    Science.gov (United States)

    Young, Mark S; Birrell, Stewart A; Stanton, Neville A

    2011-05-01

    Road transport is a significant source of both safety and environmental concerns. With climate change and fuel prices increasingly prominent on social and political agendas, many drivers are turning their thoughts to fuel efficient or 'green' (i.e., environmentally friendly) driving practices. Many vehicle manufacturers are satisfying this demand by offering green driving feedback or advice tools. However, there is a legitimate concern regarding the effects of such devices on road safety--both from the point of view of change in driving styles, as well as potential distraction caused by the in-vehicle feedback. In this paper, we appraise the benchmarks for safe and green driving, concluding that whilst they largely overlap, there are some specific circumstances in which the goals are in conflict. We go on to review current and emerging in-vehicle information systems which purport to affect safe and/or green driving, and discuss some fundamental ergonomics principles for the design of such devices. The results of the review are being used in the Foot-LITE project, aimed at developing a system to encourage 'smart'--that is safe and green--driving. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Clinical Experiences in the Surgical Treatment of Accessory Tragus

    Directory of Open Access Journals (Sweden)

    Uğur Horoz

    2016-09-01

    Full Text Available Objective: Tragus is a part of the external ear that develops from the first branchial arch. Accessory ear is a congenital external ear anomaly and has skin elevation containing remnant cartilage. The auricle develops between the 4th and 12th week of the embryonic stage, which groove the tissue from the 1st and 2nd branchial arches. Histologically, the lesions include a rugated epidermis with a thin layer stratum corneum, tiny mature hair follicles, fat lobules, and connective tissue framework that may include a central cartilage core. The aim of this study was to evaluate the accessory tragus lesions with our clinical surgical treatment results. Material and Methods: Lesions usually located anterior to the tragus and along an imaginary line drawn from the tragus to the angle of the mouth. Twelve patients admitted to our clinic between October 2011 and November 2014 were included in this study. Results: Seven boys and five girls between two–13 years old underwent operation. In total, 28 accessory ears were excised. No complications were observed during the procedure, and no complaints were noted in the postoperative period. Conclusion: Generally, limited anomaly is associated with the first and second branchial arch anomalies. Surgical excision is the standard treatment for the lesions which usually due to the esthetic concerns.

  3. Accessory genes confer a high replication rate to virulent feline immunodeficiency virus.

    Science.gov (United States)

    Troyer, Ryan M; Thompson, Jesse; Elder, John H; VandeWoude, Sue

    2013-07-01

    Feline immunodeficiency virus (FIV) is a lentivirus that causes AIDS in domestic cats, similar to human immunodeficiency virus (HIV)/AIDS in humans. The FIV accessory protein Vif abrogates the inhibition of infection by cat APOBEC3 restriction factors. FIV also encodes a multifunctional OrfA accessory protein that has characteristics similar to HIV Tat, Vpu, Vpr, and Nef. To examine the role of vif and orfA accessory genes in FIV replication and pathogenicity, we generated chimeras between two FIV molecular clones with divergent disease potentials: a highly pathogenic isolate that replicates rapidly in vitro and is associated with significant immunopathology in vivo, FIV-C36 (referred to here as high-virulence FIV [HV-FIV]), and a less-pathogenic strain, FIV-PPR (referred to here as low-virulence FIV [LV-FIV]). Using PCR-driven overlap extension, we produced viruses in which vif, orfA, or both genes from virulent HV-FIV replaced equivalent genes in LV-FIV. The generation of these chimeras is more straightforward in FIV than in primate lentiviruses, since FIV accessory gene open reading frames have very little overlap with other genes. All three chimeric viruses exhibited increased replication kinetics in vitro compared to the replication kinetics of LV-FIV. Chimeras containing HV-Vif or Vif/OrfA had replication rates equivalent to those of the virulent HV-FIV parental virus. Furthermore, small interfering RNA knockdown of feline APOBEC3 genes resulted in equalization of replication rates between LV-FIV and LV-FIV encoding HV-FIV Vif. These findings demonstrate that Vif-APOBEC interactions play a key role in controlling the replication and pathogenicity of this immunodeficiency-inducing virus in its native host species and that accessory genes act as mediators of lentiviral strain-specific virulence.

  4. Accessory Renal Artery Stenosis and Hypertension: Are These Correlated? Evaluation Using Multidetector-Row Computed Tomographic Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, L.; Sanfilippo, R.; Montisci, R.; Conti, M.; Mallarini, G. (Dept. of Imaging Science and Dept. of Vascular Surgery, Policlinico Universitario, Cagliari (Italy))

    2008-04-15

    Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH). Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized. Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements. Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733). Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension

  5. Accessory Renal Artery Stenosis and Hypertension: Are These Correlated? Evaluation Using Multidetector-Row Computed Tomographic Angiography

    International Nuclear Information System (INIS)

    Saba, L.; Sanfilippo, R.; Montisci, R.; Conti, M.; Mallarini, G.

    2008-01-01

    Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH). Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized. Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements. Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733). Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension

  6. The likely market potential for electricity saving ASD devices

    International Nuclear Information System (INIS)

    Sparow, F.T.; McKenzie, L.

    1993-01-01

    Many utility demand-side management (DSM) programs encourage the adoption of adjustable speed drives (ASD) in the industrial and commercial sectors, since such devices save KW and KWh. The term open-quotes adjustable speed drives close-quote is used to refer to any device which allows the speed of the motor to be adjusted to better match process requirements. Thus, motor input control devices, such as electronic adjustable speed drives for AC motors (i.e., adjustable frequency drives (AFD)), voltage controlled DC motors, and the use of floating pressure setpoint controls, or other devices which better control on/off compressor operation, would be considered ASD devices. Also included would be motor technologies, such as multi-speed windings, etc., which allow the synchronous speed of the motor to be altered. Not included in this definition would be mechanical systems such as gear boxes, friction disks, etc., which maintain motor speed, but alter the drive r.p.m. to the equipment. The importance of the distinction is that ASDs, as defined above, have the potential to substantially reduce KW and KWh consumption if the equipment duty cycle is varying, while mechanical drive r.p.m. varying devices don't

  7. Current drive for rotamak plasmas

    Indian Academy of Sciences (India)

    Abstract. Experiments which have been undertaken over a number of years have shown that a rotating magnetic field can drive a significant non-linear Hall current in a plasma. Successful experiments of this concept have been made with a device called rotamak. In its original configuration this device was a field reversed ...

  8. Accessory muscle of the flexor digitorum superficialis and its clinical implications

    Directory of Open Access Journals (Sweden)

    Edie Benedito Caetano

    Full Text Available ABSTRACT Anatomical variations of the flexor digitorum superficialis (FDS muscle and tendon unit are frequently reported by anatomists and clinicians. Anatomical muscle variations of the FDS and its tendons may include variations of muscle belly, presence of accessory or duplicate tendons, abnormal tendon connections, and absence of muscle or tendon components. Such variations may or may not have clinical implications. This report presents a case not described previously: a unilateral accessory muscle of the flexor digitorum superficialis which was connected by a thick tendon to the flexor digitorum superficialis muscle; it was directed proximally to the insertion of the medial epicondyle of the humerus, next to the superficialis head of the pronator teres muscle. The belly of the accessory muscle was positioned anterior to the median and anterior interosseous nerve. This anatomical variation is known as type V in the classification of Elliot et al. The knowledge of these anatomical variations helps hand surgeons interpret the clinical examination, particularly in the evaluation of patients who have suffered tendon injuries or show sign s of possible peripheral nerve entrapment.

  9. An exploration study to find important factors influencing on brand in car accessory market

    Directory of Open Access Journals (Sweden)

    Naser Azad

    2013-08-01

    Full Text Available Supplying car accessory is one of the most important growing industries in the world. Every year, millions of cars are produced and people need to have the access to necessary car accessory. In this paper, we present an exploration study to detect important factors influencing car accessory market. The proposed study designs a questionnaire in Likert scale consists of 16 questions, distributes it among 200 experts and analyses it using factor analysis. Cronbach alpha and Kaiser-Meyer-Olkin Measure of Sampling Adequacy are calculated as 0.823 and 0.863, which validate the overall questionnaire. The results indicate that there are three influencing factors including brand capability, brand characteristics and consumers’ believe.

  10. Relay protection features of frequency-adjustable electric drive

    Science.gov (United States)

    Kuprienko, V. V.

    2018-03-01

    The features of relay protection of high-voltage electric motors in composition of the frequency-adjustable electric drive are considered in the article. The influence of frequency converters on the stability of the operation of various types of relay protection used on electric motors is noted. Variants of circuits for connecting relay protection devices are suggested. The need to develop special relay protection devices for a frequency-adjustable electric drive is substantiated.

  11. ISO and EIGA standards for cryogenic vessels and accessories

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The EIGA/WG 6’s scope is cryogenic vessels and accessories, including their design, material compatibility, operational requirements and periodical inspection. The specific responsibilities include monitoring international standardization (ISO, CEN) and regulations (UN, TPED, PED...

  12. Leak detection device for control rod drive and detection method therefor

    International Nuclear Information System (INIS)

    Imasaki, Yoshio.

    1997-01-01

    The present invention provides a detection device for leak of cooling water from a sealed axial portion of control rod drives (CRD) disposed in a BWR type reactor and a monitoring method therefor. Namely, the CRD transfers rotation at the sealed axial portion and elevates/lowers a piston to insert/withdraw control rod into/from the reactor core. High pressure water is injected upon occurrence of scram to urge the piston upwardly thereby rapidly inserting the control rods. Leak detection pipelines are laid from the sealed axial portion. A flow glass is connected to the leak detection pipelines. Then, cooling water leaked from the sealed axial portion flows in the leak detection pipelines and flows into the flow glass. The flow rate of cooling water leaked from the sealed axial portion of the CRD can thus be detected by monitoring the flow glass. In addition, a flowmeter is connected to the leak detection pipelines, or the flowmeter and the flow glass are connected, and a flowmeter is connected downstream. Then, the flow rate of the leaked cooling water can be detected automatically. (I.S.)

  13. Preoperative computed tomography and scintigraphy to facilitate the detection of accessory spleen in patients with hematologic disorders

    International Nuclear Information System (INIS)

    Koyanagi, Nobuhiro; Kanematsu, Takashi; Sugimachi, Keizo

    1988-01-01

    Accessory spleens of 1.5 cm in size were preoperatively identified by the combined use of computerized tomography and splenic scintigraphy in two patients with hematologic diseases. After the accessory spleen had been removed from the first patient, who had persistent hereditary spherocytosis and had undergone a splenectomy 15 months before, a postoperative decrease in hyperbilirubinemia was noted. In the other patient who had idiopathic thrombocytopenic purpura, a successful accessory splenectomy was done at the same time as her splenectomy, and was followed by 6 months' complete remission. These events indicate that preoperative investigations using computerized tomography and scintigraphy are indispensable for ruling out an accessory spleen in those patients for whom splenectomy needs to be done in order to alleviate hematologic disorders. (author)

  14. Development of magnetic drive packless valves for commercial purpose

    International Nuclear Information System (INIS)

    Hwang, Sung Tae; Park, Jin Ho; Choi, Yoon Dong; Choi, Jong Hyun; Cho, Byung Ryeol; Kim, Tae Jun; Moon, Byung Hwan; Hong, Soon Bok; Jeong, Ji Young

    1995-09-01

    A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive valve and general/bellows-sealed valves. 5. Pressure test and strength analysis of flat circular plates under pressure. 6. Patent application. 12 tabs., 24 figs., 1 ref. (Author)

  15. Solar cell driving device. Taiyo denchi kudo sochi

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, K [Shibaura Engineering Works Co. Ltd., Tokyo (Japan)

    1991-01-24

    In driving a motor by a solar cell, if the sun light is weak, the motor cannot be started because of the fact that the start-up current of the motor is more than the current needed for driving. In this invention, a current limiting circuit is placed between the solar cell and the load, whereby the current limitation by said limiting circuit is released when the detected voltage of the solar cell reached the value required for starting the load. The current limiting circuit uses a semiconductor element such as a thyrister and a transistor which general limits a current. Such a current limiting circuit is controlled by a voltage detecting circuit and is so constructed that the cell limitation is released when a specific preset volatge of the solar cell is reached. 2 figs.

  16. Correction of accessory axillary breast tissue without visible scar.

    Science.gov (United States)

    Kim, Young Soo

    2004-01-01

    Various methods for correction of accessory axillary breast tissue have been proposed, including simple excision, diamond-shaped excision, a Y-V technique, and lipoplasty. We present an effective method for correction of a prominent axillary mound that combines lipoplasty with excision of accessory breast tissue along the axillary transverse line. Preoperative markings included an incision within the natural wrinkle line in the axillary fold, and demarcation of areas in which lipoplasty and excision were to be performed. After lipoplasty, deep dissection was performed to isolate and remove accessory breast tissue and excess fat tissue. A compression dressing was applied for 1 to 2 weeks postoperatively, and the patient was instructed to wear a sports bra for 1 to 2 months after removal of the dressing. We treated 7 patients using this procedure between October 1999 and March 2003. No major postoperative complications were detected and recurrence was not noted during the follow-up periods. Aesthetic results were satisfactory. We believe that a procedure that combines lipoplasty and excision provides numerous advantages as a surgical option in treating a prominent axillary mound. The main advantage is that the final scar is laid in the natural axillary fold, rendering scars less conspicuous and eliminating the need to remove excess skin. The one disadvantage was that elevation of the skin flap via small, remote incisions initially produced surgical difficulties, but these were overcome with experience.

  17. Forward Genetics Approach Reveals Host Genotype-Dependent Importance of Accessory Chromosomes in the Fungal Wheat Pathogen Zymoseptoria tritici

    Directory of Open Access Journals (Sweden)

    Michael Habig

    2017-11-01

    Full Text Available The fungal wheat pathogen Zymoseptoria tritici possesses a large complement of accessory chromosomes showing presence/absence polymorphism among isolates. These chromosomes encode hundreds of genes; however, their functional role and why the chromosomes have been maintained over long evolutionary times are so far not known. In this study, we addressed the functional relevance of eight accessory chromosomes in reference isolate IPO323. We induced chromosome losses by inhibiting the β-tubulin assembly during mitosis using carbendazim and generated several independent isogenic strains, each lacking one of the accessory chromosomes. We confirmed chromosome losses by electrophoretic karyotyping and whole-genome sequencing. To assess the importance of the individual chromosomes during host infection, we performed in planta assays comparing disease development results in wild-type and chromosome mutant strains. Loss of the accessory chromosomes 14, 16, 18, 19, and 21 resulted in increased virulence on wheat cultivar Runal but not on cultivars Obelisk, Titlis, and Riband. Moreover, some accessory chromosomes affected the switch from biotrophy to necrotrophy as strains lacking accessory chromosomes 14, 18, 19, and 21 showed a significantly earlier onset of necrosis than the wild type on the Runal cultivar. In general, we observed that the timing of the lifestyle switch affects the fitness of Z. tritici. Taking the results together, this study was the first to use a forward-genetics approach to demonstrate a cultivar-dependent functional relevance of the accessory chromosomes of Z. tritici during host infection.

  18. Using a smart wheelchair as a gaming device for floor-projected games: a mixed-reality environment for training powered-wheelchair driving skills.

    Science.gov (United States)

    Secoli, R; Zondervan, D; Reinkensmeyer, D

    2012-01-01

    For children with a severe disability, such as can arise from cerebral palsy, becoming independent in mobility is a critical goal. Currently, however, driver's training for powered wheelchair use is labor intensive, requiring hand-over-hand assistance from a skilled therapist to keep the trainee safe. This paper describes the design of a mixed reality environment for semi-autonomous training of wheelchair driving skills. In this system, the wheelchair is used as the gaming input device, and users train driving skills by maneuvering through floor-projected games created with a multi-projector system and a multi-camera tracking system. A force feedback joystick assists in steering and enhances safety.

  19. Safety Education in Driving. 2nd Revision.

    Science.gov (United States)

    Ohio State Univ., Columbus. Vocational Instructional Materials Lab.

    Intended for driving instruction students, this publication contains instructional materials for safety education. It contains six sections on facts and figures; defensive driving; safety devices; restraints; emergency situations; and other highway users. Each section consists of reading material followed by an activity or activities. A total of…

  20. Distractions N' Driving: video game simulation educates young drivers on the dangers of texting while driving.

    Science.gov (United States)

    Saqer, Haneen; de Visser, Ewart; Strohl, Jonathan; Parasuraman, Raja

    2012-01-01

    The proliferation of portable communication and entertainment devices has introduced new dangers to the driving environment, particularly for young and inexperienced drivers. Graduate students from George Mason University illustrate a powerful, practical, and cost-effective program that has been successful in educating these drivers on the dangers of texting while driving, which can easily be adapted and implemented in other communities.

  1. Gaze-controlled Driving

    DEFF Research Database (Denmark)

    Tall, Martin; Alapetite, Alexandre; San Agustin, Javier

    2009-01-01

    We investigate if the gaze (point of regard) can control a remote vehicle driving on a racing track. Five different input devices (on-screen buttons, mouse-pointing low-cost webcam eye tracker and two commercial eye tracking systems) provide heading and speed control on the scene view transmitted...

  2. Spinal accessory nerve schwannomas masquerading as a fourth ventricular lesion

    Directory of Open Access Journals (Sweden)

    Shyam Sundar Krishnan

    2015-01-01

    Full Text Available Schwannomas are benign lesions that arise from the nerve sheath of cranial nerves. The most common schwannomas arise from the 8 th cranial nerve (the vestibulo-cochlear nerve followed by trigeminal and facial nerves and then from glossopharyngeal, vagus, and spinal accessory nerves. Schwannomas involving the oculomotor, trochlear, abducens and hypoglossal nerves are very rare. We report a very unusual spinal accessory nerve schwannoma which occupied the fourth ventricle and extended inferiorly to the upper cervical canal. The radiological features have been detailed. The diagnostic dilemma was due to its midline posterior location mimicking a fourth ventricular lesion like medulloblastoma and ependymoma. Total excision is the ideal treatment for these tumors. A brief review of literature with tabulations of the variants has been listed.

  3. Control rod drive mechanism

    International Nuclear Information System (INIS)

    Futatsugi, Masao; Goto, Mikihiko.

    1976-01-01

    Purpose: To provide a control rod drive mechanism using water as an operating source, which prevents a phenomenon for forming two-layers of water in the neighbourhood of a return nozzle in a reactor to limit formation of excessive thermal stress to improve a safety. Constitution: In the control rod drive mechanism of the present invention, a heating device is installed in the neighbourhood of a pressure container for a reactor. This heating device is provided to heat return water in the reactor to a level equal to the temperature of reactor water thereby preventing a phenomenon for forming two-layers of water in the reactor. This limits formation of thermal stress in the return nozzle in the reactor. Accordingly, it is possible to minimize damages in the return nozzle portion and yet a possibility of failure in reactor water. (Kawakami, Y.)

  4. Ablation of an atriofascicular accessory pathway with a zero-fluoroscopy procedure

    Directory of Open Access Journals (Sweden)

    Riccardo Proietti, MD, PhD

    2015-10-01

    Full Text Available A 16-year-old patient with recurrent palpitations and documented left bundle branch block superior axis wide complex tachycardia underwent an electrophysiological study and ablation with a zero-fluoroscopy procedure. The electrophysiological study showed a decremental antegrade conducting atriofascicular pathway. Three-dimensional CARTO-guided mapping of the tricuspid annulus in sinus rhythm was performed, and a distinct signal corresponding to the accessory pathway potential of the atriofascicular pathway was found in the posterolateral region. By using an SR0 sheath and a 4-mm-tip catheter, radiofrequency application was delivered at this point on the annulus and successfully eliminated conduction through the accessory pathway.

  5. Characterization of the β-barrel assembly machine accessory lipoproteins from Borrelia burgdorferi.

    Science.gov (United States)

    Dunn, Joshua P; Kenedy, Melisha R; Iqbal, Henna; Akins, Darrin R

    2015-03-24

    Like all diderm bacteria studied to date, Borrelia burgdorferi possesses a β-barrel assembly machine (BAM) complex. The bacterial BAM complexes characterized thus far consist of an essential integral outer membrane protein designated BamA and one or more accessory proteins. The accessory proteins are typically lipid-modified proteins anchored to the inner leaflet of the outer membrane through their lipid moieties. We previously identified and characterized the B. burgdorferi BamA protein in detail and more recently identified two lipoproteins encoded by open reading frames bb0324 and bb0028 that associate with the borrelial BamA protein. The role(s) of the BAM accessory lipoproteins in B. burgdorferi is currently unknown. Structural modeling of B. burgdorferi BB0028 revealed a distinct β-propeller fold similar to the known structure for the E. coli BAM accessory lipoprotein BamB. Additionally, the structural model for BB0324 was highly similar to the known structure of BamD, which is consistent with the prior finding that BB0324 contains tetratricopeptide repeat regions similar to other BamD orthologs. Consistent with BB0028 and BB0324 being BAM accessory lipoproteins, mutants lacking expression of each protein were found to exhibit altered membrane permeability and enhanced sensitivity to various antimicrobials. Additionally, BB0028 mutants also exhibited significantly impaired in vitro growth. Finally, immunoprecipitation experiments revealed that BB0028 and BB0324 each interact specifically and independently with BamA to form the BAM complex in B. burgdorferi. Combined structural studies, functional assays, and co-immunoprecipitation experiments confirmed that BB0028 and BB0324 are the respective BamB and BamD orthologs in B. burgdorferi, and are important in membrane integrity and/or outer membrane protein localization. The borrelial BamB and BamD proteins both interact specifically and independently with BamA to form a tripartite BAM complex in B

  6. The evaluation of effectiveness of 3DCA using vacuum bag(Vac-Lock) for patient immobilization device

    International Nuclear Information System (INIS)

    Lee, Young Chul; Lee, Chul Bin; Kang, No Hyun; Kim, Dong Euk; Lee, Jung Yong; Jeong, In Pyo

    2004-01-01

    Patient immobilization is crucial factor for radiation therapy. Generally, we have been used vacuum bag immobilization device(Vac-Lock) for whole body immobilization. In order to easily set up of vacuum bag(Vac-Lock), we made a 3DCA(3-Dimensional Conformal Accessory). The purpose of this study is evaluation of effectiveness of 3DCA using Vack-Lock for patient immobilization. We made 3DCA(3-Dimensional Conformal Accessory) tool of wooden boards. The reasons to choice of wooden boards are its easily handling nature and cheap expenses. (1) We reduced man power from 5-6 persons to 1 person to make immobilizations, (2) Shortened work time from 1 hour to within 10 minutes. (3) Avoid a collision to treatment gantry head. (4) Its shapes are smart and clean. We have made and used 3DCA(3-Dimensional Conformal Accessory) tool was very effective and convenience for the patients and users.

  7. The Online Marketing Research on the Factors of Competitiveness of Enterprises in the Computer Accessory Market

    Directory of Open Access Journals (Sweden)

    Yashkina Oksana I.

    2017-04-01

    Full Text Available The article is aimed at identifyng the factors of competitiveness of enterprises in the market for computer accessories (on the example of the «ZONA51» store and suggesting certain actions as to creating and strengthening competitive advantages. The main competitors of the enterprise, which offer computer accessories, as well as the basic preferences of consumers in choosing the game-oriented computer accessories, have been explored. The study has found that price and active Internet communications are the main factors in the competitiveness of enterprises in the market for computer accessories. It is also important to use communicative channels such as «word-of-mouth marketing» for specific types of goods. The target audience of the products analyzed is young people, so it is also important to advertise resources near the places of youth gatherings to provide active communications. Further studies should consider the factors of competitiveness of Internet shops with different orientation.

  8. Neutral-beam current drive in tokamaks

    International Nuclear Information System (INIS)

    Devoto, R.S.

    1986-01-01

    The theory of neutral-beam current drive in tokamaks is reviewed. Experiments are discussed where neutral beams have been used to drive current directly and also indirectly through neoclassical effects. Application of the theory to an experimental test reactor is described. It is shown that neutral beams formed from negative ions accelerated to 500 to 700 keV are needed for this device

  9. Neutral-beam current drive in tokamaks

    International Nuclear Information System (INIS)

    Devoto, R.S.

    1987-01-01

    The theory of neutral-beam current drive in tokamaks is reviewed. Experiments are discussed where neutral beams have been used to drive current directly and also indirectly through neoclassical effects. Application of the theory to an experimental test reactor is described. It is shown that neutral beams formed from negative ions accelerated to 500-700 keV are needed for this device

  10. Antagonism of Innate Immunity by Paramyxovirus Accessory Proteins

    Directory of Open Access Journals (Sweden)

    Raychel Chambers

    2009-10-01

    Full Text Available Paramyxovirinae, a subfamily of Paramyxoviridae, are negative strand RNA viruses comprised of many important human and animal pathogens, which share a high degree of genetic and structural homology. The accessory proteins expressed from the P/V/C gene are major factors in the pathogenicity of the viruses, because of their ability to abrogate various facets of type I interferon (IFN induction and signaling. Most of the paramyxoviruses exhibit a commonality in their ability to antagonize innate immunity by blocking IFN induction and the Jak/STAT pathway. However, the manner in which the accessory proteins inhibit the pathway differs among viruses. Similarly, there are variations in the capability of the viruses to counteract intracellular detectors (RNA helicases, mda-5 and RIG-I. Furthermore, a functional specificity in the antagonism of the IFN response has been reported, suggesting that specificity in the circumvention of innate immunity restricts viral host range. Available evidence indicates that paramyxoviruses employ specific strategies to antagonize the IFN response of their specific hosts, which is one of the major factors that determine viral pathogenicity and host range.

  11. The accessory coracobrachialis muscle: ultrasound and MR features

    Energy Technology Data Exchange (ETDEWEB)

    Bauones, Salem [Centre hospitalier de l' Universite de Montreal (CHUM), Department of Radiology, Hopital Saint-Luc, Montreal, Quebec (Canada); Moraux, Antoine [Imagerie Medicale Jacquemars Gielee, Lille (France)

    2015-09-15

    To present the prevalence, clinical relevance, and ultrasound (US) and magnetic resonance imaging (MRI) appearances of the accessory coracobrachialis (ACB) muscle. We present an US prospective study of the ACB muscle over a 2-year period. Five of the eight patients with suspected ACB on US were subsequently examined by MRI. An ACB muscle was demonstrated by US in eight patients (eight shoulders), including seven females, one male, with mean age 39 years, over 770 (664 patients) consecutive shoulder US examinations referred to our institution yielding a prevalence of 1.04 %. In dynamic US assessment, one case of subcoracoid impingement secondary to a bulky ACB was diagnosed. No thoracic outlet syndrome was encountered in the remaining cases. MRI confirmed the presence of the accessory muscle in five cases. ACB muscle is a rarely reported yet not uncommon anatomic variation of the shoulder musculature encountered only in eight of 664 patients referred for shoulder US study. Its US and MRI appearance is described. One of our patients presented with subcoracoid impingement related to the presence of an ACB. (orig.)

  12. Control rod position control device

    International Nuclear Information System (INIS)

    Ubukata, Shinji.

    1997-01-01

    The present invention provides a control rod position control device which stores data such as of position signals and driving control rod instruction before and after occurrence of abnormality in control for the control rod position for controlling reactor power and utilized the data effectively for investigating the cause of abnormality. Namely, a plurality of individual control devices have an operation mismatching detection circuit for outputting signals when difference is caused between a driving instruction given to the control rod position control device and the control rod driving means and signals from a detection means for detecting an actual moving amount. A general control device collectively controls the individual control devices. In addition, there is also disposed a position storing circuit for storing position signals at least before and after the occurrence of the control rod operation mismatching. With such procedures, the cause of the abnormality can be determined based on the position signals before and after the occurrence of control rod mismatching operation stored in the position storing circuit. Accordingly, the abnormality cause can be determined to conduct restoration in an early stage. (I.S.)

  13. Releasing method of connection of control rod and its drive mechanism in a reactor

    International Nuclear Information System (INIS)

    Ishida, Kazuo; Futatsugi, Masao.

    1976-01-01

    Object: To disengage a control rod from a control rod drive device in a boiling water reactor with a minimal failure of the device, when connection there between cannot be released in a normal manner. Structure: First, a part of a piston tube in the control rod drive device is withdrawn externally of a control rod housing and cut. Next, a discharge tool, which is designed to be connected with the cut piston tube, is connected to the remainder of the piston tube within the housing and the aforesaid piston tube is pushed into the index tube. The index tube is then cut by the discharge tool. Thus, the control rod drive device and the control rod may be separated. Thereafter, the control rod may be removed from the top of the reactor container whereas the control rod drive device removed from the bottom thereof. (Ikeda, J.)

  14. Oligopeptide antigens of the angiotensin lineage compete for presentation by paraformaldehyde-treated accessory cells to T cells

    DEFF Research Database (Denmark)

    Buus, S; Werdelin, O

    1986-01-01

    series are highly susceptible to proteolytic destruction in cultures containing prefixed accessory cells. The proteases responsible for the destruction of these peptides are apparently located in the plasma membrane of accessory cells. These enzymes represent a methodologic problem in studies...

  15. Accessory enzymes influence cellulase hydrolysis of the model substrate and the realistic lignocellulosic biomass.

    Science.gov (United States)

    Sun, Fubao Fuebiol; Hong, Jiapeng; Hu, Jinguang; Saddler, Jack N; Fang, Xu; Zhang, Zhenyu; Shen, Song

    2015-11-01

    The potential of cellulase enzymes in the developing and ongoing "biorefinery" industry has provided a great motivation to develop an efficient cellulase mixture. Recent work has shown how important the role that the so-called accessory enzymes can play in an effective enzymatic hydrolysis. In this study, three newest Novozymes Cellic CTec cellulase preparations (CTec 1/2/3) were compared to hydrolyze steam pretreated lignocellulosic substrates and model substances at an identical FPA loading. These cellulase preparations were found to display significantly different hydrolytic performances irrelevant with the FPA. And this difference was even observed on the filter paper itself when the FPA based assay was revisited. The analysis of specific enzyme activity in cellulase preparations demonstrated that different accessory enzymes were mainly responsible for the discrepancy of enzymatic hydrolysis between diversified substrates and various cellulases. Such the active role of accessory enzymes present in cellulase preparations was finally verified by supplementation with β-glucosidase, xylanase and lytic polysaccharide monooxygenases AA9. This paper provides new insights into the role of accessory enzymes, which can further provide a useful reference for the rational customization of cellulase cocktails in order to realize an efficient conversion of natural lignocellulosic substrates. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Commercial Truck Driver Health and Safety: Exploring Distracted Driving Performance and Self-Reported Driving Skill.

    Science.gov (United States)

    Stavrinos, Despina; Heaton, Karen; Welburn, Sharon C; McManus, Benjamin; Griffin, Russell; Fine, Philip R

    2016-08-01

    Reducing distracters detrimental to commercial truck driving is a critical component of improving the safety performance of commercial drivers, and makes the highways safer for all drivers. This study used a driving simulator to examine effects of cell phone, texting, and email distractions as well as self-reported driver optimism bias on the driving performance of commercial truck drivers. Results revealed that more visually demanding tasks were related to poorer driving performance. However, the cell phone task resulted in less off-the-road eye glances. Drivers reporting being "very skilled" displayed poorer driving performance than those reporting being "skilled." Onboard communication devices provide a practical, yet visually and manually demanding, solution for connecting drivers and dispatchers. Trucking company policies should minimize interaction between dispatchers and drivers when the truck is in motion. Training facilities should integrate driving simulators into the instruction of commercial drivers, targeting over-confident drivers. © 2016 The Author(s).

  17. Modern Electronic Devices: An Increasingly Common Cause of Skin Disorders in Consumers.

    Science.gov (United States)

    Corazza, Monica; Minghetti, Sara; Bertoldi, Alberto Maria; Martina, Emanuela; Virgili, Annarosa; Borghi, Alessandro

    2016-01-01

    : The modern conveniences and enjoyment brought about by electronic devices bring with them some health concerns. In particular, personal electronic devices are responsible for rising cases of several skin disorders, including pressure, friction, contact dermatitis, and other physical dermatitis. The universal use of such devices, either for work or recreational purposes, will probably increase the occurrence of polymorphous skin manifestations over time. It is important for clinicians to consider electronics as potential sources of dermatological ailments, for proper patient management. We performed a literature review on skin disorders associated with the personal use of modern technology, including personal computers and laptops, personal computer accessories, mobile phones, tablets, video games, and consoles.

  18. Surface Layer Fluorination-Modulated Space Charge Behaviors in HVDC Cable Accessory

    Directory of Open Access Journals (Sweden)

    Jin Li

    2018-05-01

    Full Text Available Space charges tend to accumulate on the surface and at the interface of ethylene–propylene–diene terpolymer (EPDM, serving as high voltage direct current (HVDC cable accessory insulation, which likely induces electrical field distortion and dielectric breakdown. Direct fluorination is an effective method to modify the surface characteristics of the EPDM without altering the bulk properties too much. In this paper, the surface morphology, hydrophobic properties, relative permittivity, and DC conductivity of the EPDM before and after fluorination treatment were tested. Furthermore, the surface and interface charge behaviors in the HVDC cable accessory were investigated by the pulsed electroacoustic (PEA method, and explained from the point of view of trap distribution. The results show that fluorination helps the EPDM polymer obtain lower surface energy and relative permittivity, which is beneficial to the interface match in composite insulation systems. The lowest degree of space charge accumulation occurs in EPDM with 30 min of fluorination. After analyzing the results of the 3D potentials and the density of states (DOS behaviors in EPDM before and after fluorination, it can be found that fluorination treatment introduces shallower electron traps, and the special electrostatic potential after fluorination can significantly suppress the space charge accumulation at the interface in the HVDC cable accessory.

  19. Large - scale Rectangular Ruler Automated Verification Device

    Science.gov (United States)

    Chen, Hao; Chang, Luping; Xing, Minjian; Xie, Xie

    2018-03-01

    This paper introduces a large-scale rectangular ruler automated verification device, which consists of photoelectric autocollimator and self-designed mechanical drive car and data automatic acquisition system. The design of mechanical structure part of the device refer to optical axis design, drive part, fixture device and wheel design. The design of control system of the device refer to hardware design and software design, and the hardware mainly uses singlechip system, and the software design is the process of the photoelectric autocollimator and the automatic data acquisition process. This devices can automated achieve vertical measurement data. The reliability of the device is verified by experimental comparison. The conclusion meets the requirement of the right angle test procedure.

  20. Mechanical accessories for mobile teleoperators

    International Nuclear Information System (INIS)

    Feldman, M.J.; Herndon, J.N.

    1985-01-01

    The choice of optimum mechanical accessories for mobile teleoperators involves matching the criteria for emergency response with the available technology. This paper presents a general background to teleoperations, a potpourri of the manipulator systems available, and an argument for force reflecting manipulation. The theme presented is that the accomplishment of humanlike endeavors in hostile environments will be most successful when man model capabilities are utilized. The application of recent electronic technology to manipulator development has made new tools available to be applied to emergency response activities. The development activities described are products of the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory. 13 refs., 7 figs

  1. Digital dermatitis of the accessory digits of dairy cows

    Directory of Open Access Journals (Sweden)

    Celso A. Rodrigues

    2010-03-01

    Full Text Available This report characterizes the digital dermatitis (DD lesions in the accessory digits of dairy cows and presents data on the applied therapy. Fifteen Holstein cattle with DD affecting the accessory digits of the hindlimbs from four dairy farms with previous history of DD were evaluated. Lesions were excised, the wounds were sutured, and a topical application of oxytetracycline powder covered by bandaging was associated with a single parenteral administration of long acting oxytetracycline IM (20mg/kg. Tissue samples were obtained for histopathology and transmission electronic microscopy (TEM. Lesions from all the animals were recuperated 15 days after surgical procedure. Overal, most DD lesions were papillomatous epidermal projections or wartlike verrucous lesions. Histopathologically, samples revealed hyperplasia of epidermis with hyperkeratosis, several mitoses in the stratum basale and elongated rete ridges in the superficial and middle dermis. TEM revealed long, thin spirochete-like bacteria. Morphologic features of lesions and its response to therapy were comparable to those described for DD.

  2. Design of Fashion Accessories Using Akwa-Ocha Motifs and Symbols

    African Journals Online (AJOL)

    Nneka Umera-Okeke

    Nkpopu: holes. 16. Osikapa na ... accessories anchors in both social semiotics and archetypal theories. Social semiotics theory as ... the two earrings incorporate the Onwa (moon) motif in spherical shape and in black colour. They are held ...

  3. Neurotization of the phrenic nerve with accessory nerve for high cervical spinal cord injury with respiratory distress: an anatomic study.

    Science.gov (United States)

    Wang, Ce; Zhang, Ying; Nicholas, Tsai; Wu, Guoxin; Shi, Sheng; Bo, Yin; Wang, Xinwei; Zhou, Xuhui; Yuan, Wen

    2014-01-01

    High cervical spinal cord injury is associated with high morbidity and mortality. Traditional treatments carry various complications such as infection, pacemaker failure and undesirable movement. Thus, a secure surgical strategy with fewer complications analogous to physiological ventilation is still required. We hope to offer one potential method to decrease the complications and improve survival qualities of patients from the aspect of anatomy. The purpose of the study is to provide anatomic details on the accessory nerve and phrenic nerve for neurotization in patients with high spinal cord injuries. 38 cadavers (76 accessory and 76 phrenic nerves) were dissected in the study. The width, length and thickness of each accessory nerve and phrenic nerve above clavicle were measured. The distances from several landmarks on accessory nerve to the origin and the end of the phrenic nerve above clavicle were measured too. Then, the number of motor nerve fibers on different sections of the nerves was calculated using the technique of immunohistochemistry. The accessory nerves distal to its sternocleidomastoid muscular branches were 1.52 ± 0.32 mm ~1.54 ± 0.29 mm in width, 0.52 ± 0.18 mm ~ 0.56 ± 0.20mm in thickness and 9.52 ± 0.98 cm in length. And the phrenic nerves above clavicle were 1.44 ± 0.23 mm ~ 1.45 ± 0.24 mm in width, 0.47 ± 0.15 mm ~ 0.56 ± 0.25 mm in thickness and 6.48 ± 0.78 cm in length. The distance between the starting point of accessory nerve and phrenic nerve were 3.24 ± 1.17 cm, and the distance between the starting point of accessory nerve and the end of the phrenic nerve above clavicle were 8.72 ± 0.84 cm. The numbers of motor nerve fibers in accessory nerve were 1,038 ± 320~1,102 ± 216, before giving out the sternocleidomastoid muscular branches. The number of motor nerve fibers in the phrenic nerve was 911 ± 321~1,338 ± 467. The accessory nerve and the phrenic were similar in width, thickness and the number of motor nerve fibers. And

  4. Water pressure control device for control rod drive

    International Nuclear Information System (INIS)

    Sato, Hideyuki.

    1981-01-01

    Purpose: To minimize the fluctuations in the reactor water level upon occurrence of abnormality by inputting the level signal of the reactor to an arithmetic unit for controlling the pressure of control rod drive water to thereby enable effective reactor level control. Constitution: Signal from a flow rate transmitter is inputted into an arithmetic unit to perform constant flow rate control upon normal operation. While on the other hand, if abnormality occurs such as feedwater pump trips, the arithmetic unit is switched from the constant flow rate control to the reactor water level control. Reactor water level signal is inputted into the arithmetic unit and the control valve is most suitably controlled, whereby water is fed from CST to the reactor by way of control rod drive water system to secure the reactor water level if feedwater to the reactor is interrupted by loss of coolants on the feedwater system. Since this enables to minimize the fluctuations in the reactor water level upon abnormality, the reactor water level can be controlled most suitably by the reactor water level signal. (Moriyama, K.)

  5. Simulation of drive of mechanisms, working in specific conditions

    Science.gov (United States)

    Ivanovskaya, A. V.; Rybak, A. T.

    2018-05-01

    This paper presents a method for determining the dynamic loads on the lifting actuator device other than the conventional methods, for example, ship windlass. For such devices, the operation of their drives is typical under special conditions: different environments, the influence of hydrometeorological factors, a high level of vibration, variability of loading, etc. Hoisting devices working in such conditions are not considered in the standard; however, relevant studies concern permissible parameters of the drive devices of this kind. As an example, the article studied the work deck lifting devices - windlass. To construct a model, the windlass is represented by a rod of the variable cross-section. As a result, a mathematical model of the longitudinal oscillations of such rod is obtained. Analytic dependencies have also been obtained to determine the natural frequencies of the lowest forms of oscillations, which are necessary and are the basis for evaluating the parameters of operation of this type of the device.

  6. Acquired cavo-varus deformity caused by an accessory calcaneus: a case report and literature review

    International Nuclear Information System (INIS)

    Singh Baghla, Davinder Paul; Shariff, Sajid; Bashir, Waseem A.

    2010-01-01

    We describe an unusual cause of an acquired cavo-varus foot deformity produced by progressive enlargement of an accessory calcaneal ossicle. A 13-year-old boy with constitutional plano-valgus flat feet noted a gradual change in foot shape associated with lateral ankle pain on ambulation following an inversion injury 2 years earlier. CT and MRI scans confirmed a large accessory calcaneal ossicle lying within the sinus tarsi, with associated marrow oedema. Following surgical excision of the ossicle, the foot returned to its original shape and the symptoms were alleviated. This is the fifth reported case of an accessory calcaneal ossicle, but the only case that has occurred in a flatfooted individual. We also present the first reported MRI images of the lesion confirming pathological marrow oedema as a response to mechanical stress. (orig.)

  7. Driving error and anxiety related to iPod mp3 player use in a simulated driving experience.

    Science.gov (United States)

    Harvey, Ashley R; Carden, Randy L

    2009-08-01

    Driver distraction due to cellular phone usage has repeatedly been shown to increase the risk of vehicular accidents; however, the literature regarding the use of other personal electronic devices while driving is relatively sparse. It was hypothesized that the usage of an mp3 player would result in an increase in not only driving error while operating a driving simulator, but driver anxiety scores as well. It was also hypothesized that anxiety scores would be positively related to driving errors when using an mp3 player. 32 participants drove through a set course in a driving simulator twice, once with and once without an iPod mp3 player, with the order counterbalanced. Number of driving errors per course, such as leaving the road, impacts with stationary objects, loss of vehicular control, etc., and anxiety were significantly higher when an iPod was in use. Anxiety scores were unrelated to number of driving errors.

  8. Imaging diagnosis of accessory and cavitated uterine mass, a rare mullerian anomaly

    Directory of Open Access Journals (Sweden)

    Nishchint Jain

    2014-01-01

    Full Text Available Accessory and Cavitated Uterine Mass (ACUM is a rare form of developmental Mullerian anomaly seen in young females, which presents as chronic recurrent pelvic pain and severe dysmenorrhea. It is an accessory cavity lying within an otherwise normal uterus. It is lined by functional endometrium and surrounded by myometrium-like smooth muscle cells; hence, it bears striking macroscopic and microscopic resemblance to the uterus. Hysterosalpingography (HSG, Ultrasonography (USG, and Magnetic Resonance Imaging (MRI form the mainstay of diagnostic imaging. The entity is often under diagnosed; therefore, a high index of suspicion combined with HSG and MRI imaging can help in making an accurate diagnosis.

  9. Imaging diagnosis of accessory and cavitated uterine mass, a rare mullerian anomaly

    International Nuclear Information System (INIS)

    Jain, Nishchint; Verma, Ritu

    2014-01-01

    Accessory and Cavitated Uterine Mass (ACUM) is a rare form of developmental Mullerian anomaly seen in young females, which presents as chronic recurrent pelvic pain and severe dysmenorrhea. It is an accessory cavity lying within an otherwise normal uterus. It is lined by functional endometrium and surrounded by myometrium-like smooth muscle cells; hence, it bears striking macroscopic and microscopic resemblance to the uterus. Hysterosalpingography (HSG), Ultrasonography (USG), and Magnetic Resonance Imaging (MRI) form the mainstay of diagnostic imaging. The entity is often under diagnosed; therefore, a high index of suspicion combined with HSG and MRI imaging can help in making an accurate diagnosis

  10. Quality assurance procedure for functional performance of industrial gamma radiography exposure devices

    International Nuclear Information System (INIS)

    Kannan, R.; Yadav, R.K.; Rajoo Kumar; Bhatt, B.C.; Sivaraman, G.; Nandkumar, A.N.

    2003-05-01

    An Industrial Gamma Radiography Exposure Device (IGRED) consists of various moving parts and accessories and wear and tear take place often. This may increase the possibility of radiation incidents and result in avoidable radiation exposure. Quality assurance tests of the equipment for functional performance plays a major role in ensuring that the exposure device and its accessories perform their intended functions and satisfy radiation safety requirements to avert potential exposures to operators. Therefore, in India it is practiced as mandatory requirement that each IGRED is tested for its functional performance and only after ascertaining that features of operational safety are satisfactory, loading of the source into the radiography exposure device can be permitted. This procedure which is being. practiced since the late 1970s, has contributed significantly towards the safe use of IGREDs and minimising the occurrence of radiation accidents. The purpose of this document is to highlight the importance of periodic functional performance check of each IGRED as per the checklist for the testing procedures. It is also proposed to entrust this activity to accredited laboratories, which have the necessary infrastructure to carry out this activity. The prerequisites for accreditation of such laboratories to carry out this activity and the testing procedures to be adopted for checking the functional performance of various models of IGREDs used in this country are given in this report. (author)

  11. Anti-backlash drive systems for multi-degree freedom devices

    Science.gov (United States)

    Lungwen Tsai; Sunlai Chang.

    1993-09-14

    A new and innovative concept is described for the control of backlash in gear-coupled transmission mechanisms. The concept utilizes redundant unidirectional drives to assure positive coupling of gear meshes at all times. Based on this concept, a methodology for the enumeration of admissible redundant-drive backlash-free robotic mechanisms has been established. Some typical two- and three-DOF mechanisms are disclosed. Furthermore, actuator torques have been derived as functions of either joint torques or end-effector dynamic performance requirements. A redundantly driven gear coupled transmission mechanism manipulator has a fail-safe advantage in that, except of the loss of backlash control, it can continue to function when one of its actuators fails. A two-DOF backlash-free arm has been reduced to practice to demonstrate the principle. 20 figures.

  12. Value of local electrogram characteristics predicting successful catheter ablation of left-versus right-sided accessory atrioventricular pathways by radiofrequency current.

    Science.gov (United States)

    Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P

    1995-01-01

    Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.

  13. Disturbance Observer-Based Simple Nonlinearity Compensation for Matrix Converter Drives

    Directory of Open Access Journals (Sweden)

    Kyo-Beum Lee

    2009-01-01

    Full Text Available This paper presents a new method to compensate the nonlinearity for matrix converter drives using disturbance observer. The nonlinearity of matrix converter drives such as commutation delay, turn-on and turn-off time of switching device, and on-state switching device voltage drop is modeled by disturbance observer and compensated. The proposed method does not need any additional hardware and offline experimental measurements. The proposed compensation method is applied for high-performance induction motor drives using a 3 kW matrix converter system without a speed sensor. Simulation and experimental results show that the proposed method using disturbance observer provides good compensating characteristics.

  14. Instruments and accessories for neutron scattering research

    International Nuclear Information System (INIS)

    Ishii, Yoshinobu; Morii, Yukio

    2000-04-01

    This report describes neutron scattering instruments and accessories installed by four neutron scattering research groups at the ASRC (Advanced Science Research Center) of the JAERI and the recent topics of neutron scattering research using these instruments. The specifications of nine instruments (HRPD, BIX-I, TAS-1 and PNO in the reactor hall, RESA, BIX-II, TAS-2, LTAS and SANS-J in the guide hall of the JRR-3M) are summarized in this booklet. (author)

  15. Small Screen Use and Driving Safety.

    Science.gov (United States)

    Atchley, Paul; Strayer, David L

    2017-11-01

    The increased availability of "small screens," wireless devices with Internet-enabled connections, and their associated applications has almost overnight changed the way that we interact with our phones. The current work outlines some of the aspects of this problem as it relates to the influence of small screens on driving safety. Small screens are highly compelling to drivers, both for the information they convey and because the ability to ignore them while driving is impaired by cognitive resources used by the driving task itself. However, much is unknown about why people make choices to multitask while driving. Given the safety risks, it is recommended that parents, the public, and regulators take a stand against the use of Internet-enabled small screens unrelated to driving when the vehicle is in motion. Copyright © 2017 by the American Academy of Pediatrics.

  16. Age of licensure and monitoring teenagers' driving: survey of parents of novice teenage drivers.

    Science.gov (United States)

    McCartt, Anne T; Hellinga, Laurie A; Haire, Emily R

    2007-01-01

    To assess parental decision making regarding the timing of teenagers initiating driving and monitoring teenagers' driving after licensure. About 300 parents were interviewed during spring 2006 in Minnesota, North Carolina, and Rhode Island, states with varying licensing provisions, while teenagers took their first on-road driving tests. States' differences in ages of obtaining learner's permits and licenses reflected different licensing laws, but most teenagers obtained permits and took road tests within the first few months after they became eligible. Common reasons for delaying obtaining permits were fulfilling driver education requirements and lack of readiness/immaturity. Insufficient practice driving most often delayed licensure. Among the parents interviewed, 33-49% believed the minimum licensure age should be 17 or older. Almost all parents planned to supervise teenagers' driving after licensure, and most wanted to know about speeding or distractions. When asked about in-vehicle devices to monitor teenagers' driving, 37-59% of parents had heard of them. Parents were least interested in using video cameras and about equally interested in computer chips and cell-phone-based GPS systems. Disinterest in monitoring devices most often was attributed to trusting teenagers or respecting their privacy. Licensing laws influence ages of initiating driving. Although many parents support licensing at 17 or older - higher than in all but one state - most teenagers initiate driving soon after reaching the minimum age. Parents plan to supervise teenagers' driving, and many say they are open to using in-vehicle monitoring devices. Many parents support a minimum licensing age of 17 or older and would consider in-vehicle devices to extend their supervision of teenager's driving.

  17. Accessory enzymes from Aspergillus involved in xylan and pectin degradation

    NARCIS (Netherlands)

    Vries, de R.P.

    1999-01-01

    The xylanolytic and pectinolytic enzyme systems from Aspergillus have been the subject of study for many years. Although the main chain cleaving enzymes and their encoding genes have been studied in detail, little information is available about most of the accessory

  18. Safety Assessment of Wearing the AN/PVS-14 Monocular Night Vision Device (MNVD) and AN/AVS-6 Aviators' Night Vision Imaging System (ANVIS) During 5-Ton and HMMWV Night Driving

    National Research Council Canada - National Science Library

    Redden, Elizabeth

    2002-01-01

    .... The Communications-Electronics Command Directorate for Safety Risk Management, Fort Monmouth, New Jersey, will use the results of the assessment to determine the suitability of both devices for driving...

  19. [Design of SCM inoculation device].

    Science.gov (United States)

    Qian, Mingli; Xie, Haiyuan

    2014-01-01

    The first step of bacilli culture is inoculation bacteria on culture medium. Designing a device to increase efficiency of inoculation is significative. The new device is controlled by SCM. The stepper motor can drive the culture medium rotating, accelerating, decelerating, overturn and suspending. The device is high practicability and efficient, let inoculation easy for operator.

  20. Validated Competency Task Lists for Apparel and Accessories Marketing.

    Science.gov (United States)

    Selke-Kern, Barbara E.

    Developed by a project that validated task lists by a variety of teachers and apparel marketing business persons, this guide contains task lists for occupations in the field of apparel and accessories marketing. The guide is organized in three sections. Section 1 includes the following: (1) notes on using the information in the guide; (2) a…

  1. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  2. Semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2011-03-15

    Novel articles and methods to fabricate the same resulting in flexible, large-area, triaxially textured, single-crystal or single-crystal-like, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  3. Effectiveness of Variable Message Signs on Driving Behavior Based on a Driving Simulation Experiment

    Directory of Open Access Journals (Sweden)

    Xuedong Yan

    2014-01-01

    Full Text Available Variable message signs (VMSs, as one of the important ITS devices, provide real-time traffic information of road network to drivers in order to improve route choice and relieve the traffic congestion. In this study, the effectiveness of VMS on driving behavior was tested based on a driving simulation experiment. A road network with three levels of VMS location to route-diverging intersection and three types of VMS information format was designed in a high fidelity driving simulator platform. Fifty-two subjects who were classified by driver age, gender, and vocation successfully completed this experiment. The experimental results showed that driver characteristics, VMS location, and information format profoundly influence driving behaviors. Based on the research findings, it is suggested that VMS would be positioned between 150 m and 200 m upstream of the diverging point to balance the VMS effects on traffic safety and operation and the graphic information VMS format is better than the format with text massage only.

  4. The Natural Killer Cell Cytotoxic Function Is Modulated by HIV-1 Accessory Proteins

    Directory of Open Access Journals (Sweden)

    Edward Barker

    2011-07-01

    Full Text Available Natural killer (NK cells’ major role in the control of viruses is to eliminate established infected cells. The capacity of NK cells to kill virus-infected cells is dependent on the interactions between ligands on the infected cell and receptors on the NK cell surface. Because of the importance of ligand-receptor interactions in modulating the NK cell cytotoxic response, HIV has developed strategies to regulate various NK cell ligands making the infected cell surprisingly refractory to NK cell lysis. This is perplexing because the HIV-1 accessory protein Vpr induces expression of ligands for the NK cell activating receptor, NKG2D. In addition, the accessory protein Nef removes the inhibitory ligands HLA-A and -B. The reason for the ineffective killing by NK cells despite the strong potential to eliminate infected cells is due to HIV-1 Vpu’s ability to down modulate the co-activation ligand, NTB-A, from the cell surface. Down modulation of NTB-A prevents efficient NK cell degranulation. This review will focus on the mechanisms through which the HIV-1 accessory proteins modulate their respective ligands, and its implication for NK cell killing of HIV-infected cells.

  5. Newborn Interneurons in the Accessory Olfactory Bulb Promote Mate Recognition in Female Mice

    Directory of Open Access Journals (Sweden)

    Livio eOboti

    2011-09-01

    Full Text Available In the olfactory bulb of adult rodents, local interneurons are constantly replaced by immature precursors derived from the subventricular zone. Whether any olfactory sensory process specifically relies on this cell renewal remains largely unclear. By using the well-known model of mating-induced imprinting, we demonstrate that this olfactory memory formation critically depends on the presence of newborn granule neurons in the accessory olfactory bulb. Accordingly, we show that, in adult female mice, exposure to male pheromones increases the number of new granule cells surviving in the accessory olfactory bulb. This neuronal addition depends on the detection of sensory cues by the vomeronasal organ and requires centrifugal feedback activity from the amygdala. The stimuli affecting neuronal survival are contained in the low molecular weight fraction of urine and are implied in pheromonal recognition during mating. By chemical depletion of newly generated bulbar interneurons, we show a direct role of renewed granule cells in the accessory olfactory bulb in preventing pregnancy block by mating male odours. Taken together, our results indicate that adult neurogenesis is essential for specific brain functions such as persistent odour learning and mate recognition.

  6. Applications of antireflection coatings in sonic crystal-based acoustic devices

    International Nuclear Information System (INIS)

    Wang Yun; Deng Ke; Xu Shengjun; Qiu Chunyin; Yang Hai; Liu Zhengyou

    2011-01-01

    The unwanted reflection seriously baffles the practical applications of sonic crystals, such as for various acoustic lenses designed by utilizing the in-band properties of sonic crystals. Herein we introduce the concept of the antireflection coating into the sonic crystal-based devices. The efficiency of such accessorial structures is demonstrated well by an originally high reflection system. Promising perspectives can be anticipated in extending the antireflection coating layers into more general acoustic applications through a flexible design process.

  7. Drunk driving warning system (DDWS). Volume 2, Field test evaluation

    Science.gov (United States)

    1983-12-01

    The Drunk Driving Warning System (DDWS) is a vehicle-mounted device for testing driver impairment and activating alarms. The driver must pass a steering competency test (the Critical Tracking Task or CTT) in order to drive the car in a normal manner....

  8. Comparison of the accuracy of three algorithms in predicting accessory pathways among adult Wolff-Parkinson-White syndrome patients.

    Science.gov (United States)

    Maden, Orhan; Balci, Kevser Gülcihan; Selcuk, Mehmet Timur; Balci, Mustafa Mücahit; Açar, Burak; Unal, Sefa; Kara, Meryem; Selcuk, Hatice

    2015-12-01

    The aim of this study was to investigate the accuracy of three algorithms in predicting accessory pathway locations in adult patients with Wolff-Parkinson-White syndrome in Turkish population. A total of 207 adult patients with Wolff-Parkinson-White syndrome were retrospectively analyzed. The most preexcited 12-lead electrocardiogram in sinus rhythm was used for analysis. Two investigators blinded to the patient data used three algorithms for prediction of accessory pathway location. Among all locations, 48.5% were left-sided, 44% were right-sided, and 7.5% were located in the midseptum or anteroseptum. When only exact locations were accepted as match, predictive accuracy for Chiang was 71.5%, 72.4% for d'Avila, and 71.5% for Arruda. The percentage of predictive accuracy of all algorithms did not differ between the algorithms (p = 1.000; p = 0.875; p = 0.885, respectively). The best algorithm for prediction of right-sided, left-sided, and anteroseptal and midseptal accessory pathways was Arruda (p algorithms were similar in predicting accessory pathway location and the predicted accuracy was lower than previously reported by their authors. However, according to the accessory pathway site, the algorithm designed by Arruda et al. showed better predictions than the other algorithms and using this algorithm may provide advantages before a planned ablation.

  9. Accessory papillary muscles and papillary muscle hypertrophy are associated with sudden cardiac arrest of unknown cause.

    Science.gov (United States)

    Uhm, Jae-Sun; Youn, Jong-Chan; Lee, Hye-Jeong; Park, Junbeom; Park, Jin-Kyu; Shim, Chi Young; Hong, Geu-Ru; Joung, Boyoung; Pak, Hui-Nam; Lee, Moon-Hyoung

    2015-10-15

    The present study was performed for elucidating the associations between the morphology of the papillary muscles (PMs) and sudden cardiac arrest (SCA). We retrospectively reviewed history, laboratory data, electrocardiography, echocardiography, coronary angiography, and cardiac CT/MRI for 190 patients with SCA. The prevalence of accessory PMs and PM hypertrophy in patients with SCA of unknown cause was compared with that in patients with SCA of known causes and 98 age- and sex-matched patients without SCA. An accessory PM was defined as a PM with origins separated from the anterolateral and posteromedial PMs, or a PM that branched into two or three bellies at the base of the anterolateral or posteromedial PM. PM hypertrophy was defined as at least one of the two PMs having a diameter of ≥1.1cm. In 49 patients (age 49.9±15.9years; 38 men) the cause of SCA was unknown, whereas 141 (age 54.2±16.6years; 121 men) had a known cause. The prevalence of accessory PMs was significantly higher in the unknown-cause group than in the known-cause group (24.5% and 7.8%, respectively; p=0.002) or the no-SCA group (7.1%, p=0.003). The same was true for PM hypertrophy (unknown-cause 12.2%, known-cause 2.1%, p=0.010; no SCA group 1.0%, p=0.006). By logistic regression, accessory PM and PM hypertrophy were independently associated with sudden cardiac arrest of unknown cause. An accessory PM and PM hypertrophy are associated with SCA of unknown cause. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Accessory hepatic lobe simulating a left hemidiaphragmatic tumor

    International Nuclear Information System (INIS)

    Kuroiwa, Toshiro; Hirata, Hitoshi; Iwashita, Akinori; Yasumori, Kotaro; Mogami, Hiroshi; Teraoka, Hiroaki

    1984-01-01

    A 72-year-old woman with a 20-year history of neuralgia was confirmed at surgery to have a tumor in the left hemidiaphragmatic region which was connected with the left lobe of the liver. Reassessment of radiological diagnosis after surgery revealed that hepatobiliary scintigraphy and computed tomography using left anterior oblique scanning are useful in differentiating the accessory hepatic lobe of the liver from a tumor and in confirming the diagnosis, respectively. (Namekawa, K.)

  11. Ion trap device

    Science.gov (United States)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  12. Prophylactic accessory-pathway ablation in asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern.

    Science.gov (United States)

    Ozenc, S; Iscen, S; Kibrisli, E; Tok, D; Parlak, A; Altinel, O; Altinel, S

    2014-01-01

    The optimal approach is controversial in asymptomatic patients who are coincidentally found to have evidence of an accessory pathway (AP) on an ECG. The risk of sudden cardiac death (SCD) is low, and the risk of developing symptoms also appears to be low, although a wide range of incidences have been reported. In our trial, we tested the hypothesis that if prophylactic accessory-pathway ablation performed at the time of the initial electrophysiological testing would improve the long-term outcome in asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern. Recruitment of patients began on February 1, 2004, and ended on February 5, 2009. All 110 asymptomatic patients were hospitalized and underwent electrophysiological testing the same day to assess the inducibility of atrioventricular reciprocating tachycardia. The anterograde effective refractory period of the accessory pathway was defined as the longest coupling interval at which anterograde block in the bypass tract was observed. For the statistical analysis, the statistical software SPSS version 15.0 for Windows (SPSS Inc., Chicago, IL, USA). Of 110 asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern, 80 patients were ablated. Ablation group consisted of these patients. Control group consisted of remaining 30 and were divided into two groups according to the anterograde effective refractory period of the accessory pathway. There was no significant difference between three groups in terms of arrhythmic events (p: 0.58). Asymptomatic patients with the Wolff-Parkinson-White syndrome do not require prophylactic ablation, since they remain asymptomatic for many years.

  13. Device for discharging drain in a control rod driving apparatus

    International Nuclear Information System (INIS)

    Ikeda, Tadasu; Ikuta, Takuzo; Yoshida, Tomiji; Tsukahara, Katsumi.

    1975-01-01

    Object: To efficiently and safely collect and discharge drain by a simple construction in which a drain cover and a drain tank in a control rod driving apparatus are integrally formed, and an overhauling wrench of said apparatus and a drain hose are mounted on the drain tank. Structure: When a mounting bolt is untightened by a torque wrench so as to be removed from a flange surface of the control rod driving apparatus in a nuclear reactor, axial movement of said apparatus is absorbed by a spring so that drain containing a radioactive material is discharged into a drain tank through the flange surface of said apparatus and is then guided into a collecting tank through a drain hose. (Kamimura, M.)

  14. An Asymptomatic Case of Wolff-Parkinson-White Syndrome with Right-sided Free-wall Accessory Pathway and Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Takanao Mine, MD

    2011-01-01

    Full Text Available A 16-year-old girl with a known history of asymptomatic Wolff-Parkinson-White syndrome exhibited signs of left ventricular (LV septal akinesia and LV dysfunction during routine follow-up. A 12-lead surface ECG showed pre-excitation, a predominantly negative delta wave in V1 and left axis deviation, which was consistent with the presence of a right free-wall accessory pathway. Radiofrequency ablation of the anterolateral right atrium around the local shortest atrium-to-ventricle interval created the accessory pathway block. An echocardiogram taken one month after the procedure revealed that LV septal wall motion had normalized and that LV ejection fraction had improved from 50% before the ablation to 64% after the ablation. Most previous reports of asymptomatic patients of WPW with LV septal dyskinesia and dysfunction have described right septal or posteroseptal accessory pathways. This patient reported here represents a rare case with right free-wall accessory pathway and LV dysfunction without tachycardia.

  15. Enhanced luminance for inorganic electroluminescent devices with a charged electret

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Fang-Hsing, E-mail: fansen@dragon.nchu.edu.tw [Department of Electrical Engineering and Graduate Institute of Optoelectronic Engineering, National Chung Hsing University, Taichung 402, Taiwan, ROC (China); Chen, Kuo-Feng [Department of Electrical Engineering and Graduate Institute of Optoelectronic Engineering, National Chung Hsing University, Taichung 402, Taiwan, ROC (China); Display Technology Center/Industrial Technology Research Institute, Hsinchu 310, Taiwan, ROC (China); Chien, Yu-Han; Chang, Chin-Chia; Chuang, Meng-Ying [Display Technology Center/Industrial Technology Research Institute, Hsinchu 310, Taiwan, ROC (China)

    2013-09-15

    This work proposes a novel inorganic electroluminescent (IEL) device with an electric field built-in (EFBI) technique to reduce its driving voltage and enhance its luminance. The EFBI technique was performed by charging an electret comprising a silicon dioxide film at different temperatures (25–150 °C) in powder electroluminescent (PDEL) devices. The driving voltage of the EFBI-PDEL device decreased by 61.4 V (or 20.5%) under the brightness of 269 cd/m{sup 2}, and its brightness increased by 128 cd/m{sup 2} (or 47%) at ac 300 V. The efficiency of the EFBI-PDEL device significantly increased by 0.827 lm/W (or 45.5%) at ac 300 V. The proposed EFBI-PDEL device has advantages of a low-temperature process and low cost, and potential for large-area display applications. -- Highlights: • An electric-field built-in powder electroluminescent (EFBI-PDEL) device is proposed. • The EFBI technique is performed by charging an electrets. • The driving voltage of the EFBI-PDEL device decreased by 20.5%. • The brightness of the EFBI-PDEL device increased by 47%. • The efficiency of the EFBI-PDEL device increased by 45.5%.

  16. Accessory Proteins at ERES

    DEFF Research Database (Denmark)

    Klinkenberg, Rafael David

    membrane targeting and association with ERES. We determine the localization of Sec16B by transient expression in HeLa cells, and find that the protein is evenly distributed throughout the cell except the nucleus at 37°C, as is also observed with mSec16A. When the temperature is lowered to 15°C, mSec16B...... proteins. Together these components co‐operate in cargo‐selection as well as forming, loading and releasing budding vesicles from specific regions on the membrane surface of the ER. Coat components furthermore convey vesicle targeting towards the Golgi. However, not much is known about the mechanisms...... that regulate the COPII assembly at the vesicle bud site. This thesis provides the first regulatory mechanism of COPII assembly in relation to ER‐membrane lipid‐signal recognition by the accessory protein p125A (Sec23IP). The aim of the project was to characterize p125A function by dissecting two main domains...

  17. Current drive in a ponderomotive potential with sign reversal

    International Nuclear Information System (INIS)

    Fisch, N.J.; Dodin, I.Y.; Rax, J.M.

    2003-01-01

    Noninductive current drive can be accomplished through ponderomotive forces with high efficiency when the potential changes sign over the interaction region. The effect, which operates somewhat like a Maxwell demon, can be practiced upon both ions and electrons. The current-drive efficiencies, in principle, might be higher than those possible with conventional rf current-drive techniques. It remains, however, for us to identify how the effect might be implemented in a magnetic fusion device in a practical manner

  18. Low emission turbo compound engine system

    Science.gov (United States)

    Vuk,; Carl, T [Denver, IA

    2011-05-31

    A diesel or HHCI engine has an air intake and an exhaust for products of combustion. A pair of turbochargers receive the products of combustion in a series relationship and an exhaust aftertreatment device receive the products of combustion from the downstream turbine. A power turbine receives the output from the exhaust aftertreatment device and an EGR system of the power turbine passes a selected portion of the output to a point upstream of the upstream turbocharger compressor. A device adds fuel to the aftertreatment device to regenerate the particulate filter and the power turbine recoups the additional energy. The power turbine may be used to drive accessories or the prime output of the engine.

  19. Physician accessories: Doctor, what you carry is every patient′s worry?

    Directory of Open Access Journals (Sweden)

    Pandey Anita

    2010-10-01

    Full Text Available Background: Nosocomial infections are on the rise worldwide and many a times they are carried by the health care personnel. Accessories used by physicians and healthcare personnel can be a potential source of nosocomial infection. Materials and Methods: We designed a survey with the aim to investigate the prevalence of microbial flora of accessories such as pens, stethoscopes, cell phones and white coat used by the physicians working in a tertiary care hospital. Observations: It was observed that 66% of the pens, 55% of the stethoscopes, 47.61% of the cell phones and 28.46% of the white coats used by the doctors were colonized with various microorganisms. Staphylococcus spp. was the predominant isolate followed by Escherichia coli. Methicillin resistance in Staphylococcus aureus was also found, which was a matter of concern. Conclusions: Awareness of appropriate hand hygiene is important in order to prevent potential transmission to patients.

  20. Morphological and clinical aspects of the occurrence of accessory (multiple) renal arteries

    Science.gov (United States)

    Gulas, Ewelina; Wysiadecki, Grzegorz; Szymański, Jacek; Majos, Agata; Stefańczyk, Ludomir; Topol, Mirosław

    2016-01-01

    Renal vascularization variants vastly differ between individuals due to the very complex embryogenesis of the kidneys. Moreover, each variant may have implications for clinical and surgical interventions. The number of operating procedures continues to grow, and includes renal transplants, aneurysmorrhaphy and other vascular reconstructions. In any surgical technique, unawareness of the presence of multiple renal arteries may result in a fatal outcome, especially if laparoscopic methods are used. The aim of this review is to comprehensively identify the variation within multiple renal arteries and to highlight the connections between the presence of accessory renal arteries and the coexistence of other variants of vascularization. Another aim is to determine the potential clinical implications of the presence of accessory renal arteries. This study is of particular importance for surgeons, intervention radiologists, nephrologists and vascular surgeons. PMID:29593819

  1. Drunk driving warning system (DDWS). Volume 1, System concept and description

    Science.gov (United States)

    1983-11-01

    The Drunk Driving Warning System (DDWS) is a vehicle-mounted device for testing driver impairment and activating alarms. The driver must pass a steering competency test in order to drive the car in a normal manner. The emergency flasher system operat...

  2. Device for coupling a control rod and control rod drive

    International Nuclear Information System (INIS)

    Nishioka, Kazuya.

    1975-01-01

    Object: To obtain simple and reliable coupling between a control rod and control rod drive by equipping the lower end of the control rod with an extension provided with lateral protuberances and forming the upper end of an index tube with a recess provided with lateral holes. Structure: The tapering central extension of the control rod is inserted into the recess by lowering the control rod, and then it is further inserted by causing frictional movement of the inclined surfaces of lateral protuberances in frictional contact with guide surfaces. When the lateral protuberances are brought into contact with a stepped portion, the control rod is rotated to fit the lateral protuberances into the lateral holes. In this way, the control rod is coupled to the index tube of the control rod drive. (Yoshino, Y.)

  3. Ignition systems and blasting accessories; L'amorcage et les accessoires de tir

    Energy Technology Data Exchange (ETDEWEB)

    Du Mouza, J. [Ecole Nationale Superieure des Mines, 75 - Paris (France); Monnery, J. [SFEPA, 92 - Puteaux (France); Vuillaume, P. [Institut National de l' Environnement Industriel et des Risques, 60 - Verneuil en Halatte (INERIS) (France); Cervellera, St. [Titanite SA, 21 - Pontailler sur Saone (France); Houeix, T.

    2002-03-01

    1. General: Blasting caps or detonators are the main elements of the pyrotechnical sequence. They should be reliable in order to guaranty the quality, the safety and the energy liberated by the explosive. They transmit to the explosive the minimum required energy to initiate the detonation. The pyrotechnical sequence comprises a mechanical or electrical device, the blasting cap able to produce a shock or a spark initiating the explosion directly or through a primary explosive more sensible than the main one. 2. Initiation systems: Various types of systems are described determining the way the shock wave is propagated within the explosive. Initiation may be made punctually, by means of a detonator or laterally by means of a cord. Detonators may be operated electrically, non-electrically or electronically. Special devices allow for the retardation of the initiation. 3. Retardation reliability and accuracy: Some points about the consequences of dispersions in lengths of retardation of detonators such as the possible overlapping of explosive loads and combination of vibration trains in the environment are discussed. A smaller dispersion offered by electronic detonators, which are by far the most frequently used, should be able to overcome these difficulties. 4. Impact of the initiation on the explosive yield: The way the ignition is performed has a direct consequence on the yield of the explosive. When a primer explosive is utilised as a booster, various factors (weight, position and diameter) play an important role on the detonation pressure and speed. A chart indicates the explosive energy liberated depending on the way ignition is performed. 5. Blasting accessories: Dynamos were largely used in the past to generate the electric current required to actuate blasting caps. Now this electric current is generated by the discharge of capacitors associated with electronic devices to control the blasting sequence. Ohmmeters are also used to check the electric circuits

  4. Distracted Driving, A Major Preventable Cause of Motor Vehicle Collisions: "Just Hang Up and Drive".

    Science.gov (United States)

    Kahn, Christopher A; Cisneros, Victor; Lotfipour, Shahram; Imani, Ghasem; Chakravarthy, Bharath

    2015-12-01

    For years, public health experts have been concerned about the effect of cell phone use on motor vehicle collisions, part of a phenomenon known as "distracted driving." The Morbidity and Mortality Weekly Report (MMWR) article "Mobile Device Use While Driving - United States and Seven European Countries 2011" highlights the international nature of these concerns. Recent (2011) estimates from the National Highway Traffic Safety Administration are that 10% of fatal crashes and 17% of injury crashes were reported as distraction-affected. Of 3,331 people killed in 2011 on roadways in the U.S. as a result of driver distraction, 385 died in a crash where at least one driver was using a cell phone. For drivers 15-19 years old involved in a fatal crash, 21% of the distracted drivers were distracted by the use of cell phones. Efforts to reduce cell phone use while driving could reduce the prevalence of automobile crashes related to distracted driving. The MMWR report shows that there is much ground to cover with distracted driving. Emergency physicians frequently see the devastating effects of distracted driving on a daily basis and should take a more active role on sharing the information with patients, administrators, legislators, friends and family.

  5. Reactive Hypertrophy of an Accessory Spleen Mimicking Tumour Recurrence of Metastatic Renal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Christin Tjaden

    2011-01-01

    Full Text Available De novo occurrence of an accessory spleen after splenectomy is worth noting for two reasons. First, it is known that splenectomy can cause reactive hypertrophy of initially inactive and macroscopically invisible splenic tissue. Second, it can mimic tumour recurrence in situations in which splenectomy has been performed for oncological reasons. This might cause difficulties in differential diagnosis and the clinical decision for reoperation. We report the case of a patient with suspected recurrence of renal cell carcinoma after total pancreatectomy and splenectomy for metastatic renal cell carcinoma, which finally revealed an accessory spleen as the morphological correlate of the newly diagnosed mass in the left retroperitoneum.

  6. Personal Computer Based Controller For Switched Reluctance Motor Drives

    Science.gov (United States)

    Mang, X.; Krishnan, R.; Adkar, S.; Chandramouli, G.

    1987-10-01

    Th9, switched reluctance motor (SRM) has recently gained considerable attention in the variable speed drive market. Two important factors that have contributed to this are, the simplicity of construction and the possibility of developing low cost con-trollers with minimum number of switching devices in the drive circuits. This is mainly due to the state-of-art of the present digital circuits technology and the low cost of switching devices. The control of this motor drive is under research. Optimized performance of the SRM motor drive is very dependent on the integration of the controller, converter and the motor. This research on system integration involves considerable changes in the control algorithms and their implementation. A Personal computer (PC) based controller is very appropriate for this purpose. Accordingly, the present paper is concerned with the design of a PC based controller for a SRM. The PC allows for real-time microprocessor control with the possibility of on-line system parameter modifications. Software reconfiguration of this controller is easier than a hardware based controller. User friendliness is a natural consequence of such a system. Considering the low cost of PCs, this controller will offer an excellent cost-effective means of studying the control strategies for the SRM drive intop greater detail than in the past.

  7. Successful Ablation of Antero-septal Accessory Pathway in the Non-Coronary Cusp in a Child

    Directory of Open Access Journals (Sweden)

    Daisuke Kobayashi, MD

    2012-05-01

    Full Text Available A 15-year-old boy with Wolff-Parkinson-White syndrome underwent an electrophysiology study for symptoms of palpitations and persistence of pre-excitation during peak exercise. He was detected to have right antero-septal accessory pathway with relatively long effective refractory period and no inducible tachycardia. He had only transient normalization with cryoablation. Eight months later, he presented again with two episodes of seizures with preceding palpitations. Neurology evaluation was unremarkable with a normal electroencephalogram. In view of his symptoms in association with evidence of pre-excitation, he underwent a second electrophysiology study with ablation. Cryoablation in the anterior septum again achieved only transient normalization. Mapping in the non-coronary cusp identified an earliest accessory pathway potential. RF ablation was performed in the non- coronary cusp with immediate normalization of his electrocardiogram. At 6 month follow-up, he continues to have no pre-excitation on his EKG. Ablation of the anteroseptal accessory pathway in the non-coronary cusp can be safely performed in patients’ refractory to conventional ablation sites and techniques.

  8. 49 CFR 398.5 - Parts and accessories necessary for safe operation.

    Science.gov (United States)

    2010-10-01

    ... REGULATIONS TRANSPORTATION OF MIGRANT WORKERS § 398.5 Parts and accessories necessary for safe operation. (a... not be of welded construction. The installation shall be such as not to cause cracking, warping, or... high, by attachment of sideboards to the permanent body construction if necessary. Stake body...

  9. 41 CFR 101-39.304 - Modification or installation of accessory equipment.

    Science.gov (United States)

    2010-07-01

    ..., TRANSPORTATION, AND MOTOR VEHICLES 39-INTERAGENCY FLEET MANAGEMENT SYSTEMS 39.3-Use and Care of GSA Interagency Fleet Management System Vehicles § 101-39.304 Modification or installation of accessory equipment. The modification of a GSA Interagency Fleet Management System (IFMS) vehicle or the permanent installation of...

  10. Shoulder complaints after neck dissection; is the spinal accessory nerve involved?

    NARCIS (Netherlands)

    van Wilgen, C.P.; Dijkstra, P.U.; van der Laan, B.F.; Plukker, J.T.; Roodenburg, J.L.

    The purpose of the current study was to investigate the relation between shoulder morbidity (pain and range of motion), and the function of the spinal accessory nerve after neck dissection. Identifying dysfunction of the nerve gives insight in the mechanisms of post-operative shoulder complaints. In

  11. Context-Based Filtering for Assisted Brain-Actuated Wheelchair Driving

    Directory of Open Access Journals (Sweden)

    Gerolf Vanacker

    2007-01-01

    Full Text Available Controlling a robotic device by using human brain signals is an interesting and challenging task. The device may be complicated to control and the nonstationary nature of the brain signals provides for a rather unstable input. With the use of intelligent processing algorithms adapted to the task at hand, however, the performance can be increased. This paper introduces a shared control system that helps the subject in driving an intelligent wheelchair with a noninvasive brain interface. The subject's steering intentions are estimated from electroencephalogram (EEG signals and passed through to the shared control system before being sent to the wheelchair motors. Experimental results show a possibility for significant improvement in the overall driving performance when using the shared control system compared to driving without it. These results have been obtained with 2 healthy subjects during their first day of training with the brain-actuated wheelchair.

  12. Counter-diabatic driving for Dirac dynamics

    Science.gov (United States)

    Fan, Qi-Zhen; Cheng, Xiao-Hang; Chen, Xi

    2018-03-01

    In this paper, we investigate the fast quantum control of Dirac equation dynamics by counter-diabatic driving, sharing the concept of shortcut to adiabaticity. We systematically calculate the counter-diabatic terms in different Dirac systems, like graphene and trapped ions. Specially, the fast and robust population inversion processes are achieved in Dirac system, taking into account the quantum simulation with trapped ions. In addition, the population transfer between two bands can be suppressed by counter-diabatic driving in graphene system, which might have potential applications in opt-electric devices.

  13. Online monitoring of Accessories for Underground Electrical Installations through Acoustics Emissions

    Directory of Open Access Journals (Sweden)

    Casals-Torrens P.

    2012-04-01

    Full Text Available The acoustic waves caused by Partial Discharges inside the dielectric materials, can be detected by acoustic emission (AE sensors and analyzed in the time domain. The experimental results presented, show the online detection capability of these sensors in the environment near a cable accessory, such as a splice or terminal. The AE sensors are immune to electromagnetic interference and constitute a detection method non-intrusive and non-destructive, which ensures a galvanic decoupling with respect to electric networks, this technique of partial discharge detection can be applied as a test method for preventive or predictive maintenance (condition-based maintenance to equipments or facilities of medium and high voltage in service and represents an alternative method to electrical detection systems, conventional or not, that continue to rely on the detection of current pulses. This paper presents characterization tests of the sensors AE through comparative tests of partial discharge on accessories for underground power cables.

  14. A gate drive circuit for gate-turn-off (GTO) devices in series stack

    International Nuclear Information System (INIS)

    Despe, O.

    1999-01-01

    A gate-turn-off (GTO) switch is under development at the Advanced Photon Source as a replacement for a thyratron switch in high power pulsed application. The high voltage in the application requires multiple GTOs connected in series. One component that is critical to the success of GTO operation is the gate drive circuit. The gate drive circuit has to provide fast high-current pulses to the GTO gate for fast turn-on and turn-off. It also has to be able to operate while floating at high voltage. This paper describes a gate drive circuit that meets these requirements

  15. Accessory Breast Cancer Occurring Concurrently with Bilateral Primary Invasive Breast Carcinomas: A Report of Two Cases and Literature Review

    International Nuclear Information System (INIS)

    Hao, Jin-yan; Yang, Cui-cui; Liu, Fang-fang; Yang, Yi-ling; Li, Shuai; Li, Wei-dong; Li, Ya-qing; Lang, Rong-gang; Fan, Yu; Paulos, Estifanos; Zhang, Xin-min; Fu, Li

    2012-01-01

    The development of accessory breast tissue, which is found anywhere along the milk line, is attributed to the failure of milk line remnants to regress during embryogenesis. Primary tumors may arise from any ectopic breast tissue. Accessory breast cancer occurring concurrently with primary invasive breast cancer is extremely rare. Two such cases were reported in this article. One was a 43-year-old Chinese female who exhibited bilateral breast cancer (invasive ductal carcinoma, not otherwise specified, IDC-NOS) and an accessory breast carcinoma (IDC-NOS) incidentally identified in her left axilla. The ectopic breast tissue in her right axilla presented with adenosis. The patient was surgically treated, followed by postoperative docetaxel epirubicin (TE) chemotherapy. The second case was a 53-year-old Chinese female with bilateral breast cancer (apocrine carcinoma) accompanied by an accessory breast carcinoma (IDC-NOS) in her right axilla that was also incidentally identified. The patient was surgically treated after three doses of cyclophosphamide epirubicin docetaxel (CET) neoadjuvant chemotherapy, followed by adjuvant chemotherapy of the same regimen

  16. Underwater radiation measuring device

    International Nuclear Information System (INIS)

    Seki, Noriyuki; Suzuki, Yasuo

    1998-01-01

    The present invention provides a device for measuring, under water, radiation from spent fuels (long members to be detected) of nuclear power plants and reprocessing facilities. Namely, a detecting insertion tube (insertion tube) is disposed so as to be in parallel with axial direction of the long member to be detected stored underwater. A γ-ray detector is inserted to the inside of the insertion tube. A driving mechanism is disposed for moving the γ-ray detector in axial direction inside of the insertion tube. The driving mechanism preferably has a system that it moves the γ-ray detector by winding a detection signal cable around a driving drum. The driving mechanism is formed by inserting and securing a driving tube having screws formed on the side surface and inserting it into the insertion tube. It may have a system of moving the γ-ray detector together with the driving tube while engaging the teeth of a driving transfer mechanism with the screws of the driving tube. (I.S.)

  17. Effect of pile-driving sounds on the survival of larval fish

    NARCIS (Netherlands)

    Bolle, L.J.; Jong, C.A.F. de; Bierman, S.M.; Beek, P.J.G. van van; Wessels, P.W.; Blom, E.; Damme, C.J.G. van; Winter, H.V.; Dekeling, R.P.A.

    2016-01-01

    Concern exists about the potential effects of pile-driving sounds on fish, but evidence is limited, especially for fish larvae. A device was developed to expose larvae to accurately reproduced pile-driving sounds. Controlled exposure experiments were carried out to examine the lethal effects in

  18. Design of the driving system for visible near-infrared spatial programmable push-broom remote CCD sensor

    Science.gov (United States)

    Xu, Zhipeng; Wei, Jun; Zhou, Qianting; Weng, Dongshan; Li, Jianwei

    2010-11-01

    VNIR multi-spectral image sensor has wide applications in remote sensing and imaging spectroscopy. An image spectrometer of a spatial remote programmable push-broom sensing satellite requires visible near infrared band ranges from 0.4μm to 1.04μm which is one of the most important bands in remote sensing. This paper introduces a method of design the driving system for 1024x1024 VNIR CCD sensor for programmable push-broom remote sensing. The digital driving signal is generated by the FPGA device. There are seven modules in the FPGA program and all the modules are coded by VHDL. The driving system have five mainly functions: drive the sensor as the demand of timing schedule, control the AD convert device to work, get the parameter via RS232 from control platform, process the data input from the AD device, output the processed data to PCI sample card to display in computer end. All the modules above succeed working on FPGA device APA600. This paper also introduced several important keys when designing the driving system including module synchronization, critical path optimization.

  19. High Torque, Direct Drive Electric Motor, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Bear Engineering proposes to develop an innovative high torque, low speed, direct drive motor in order to meet NASA's requirements for such devices. Fundamentally,...

  20. Properties of Phase Transition of Traffic Flow on Urban Expressway Systems with Ramps and Accessory Roads

    International Nuclear Information System (INIS)

    Mei Chaoqun; Liu Yejin

    2011-01-01

    In this paper, we develop a cellular automaton model to describe the phase transition of traffic flow on urban expressway systems with on-off-ramps and accessory roads. The lane changing rules are given in detailed, the numerical results show that the main road and the accessory road both produce phase transitions. These phase transitions will often be influenced by the number of lanes, lane changing, the ramp flow, the input flow rate, and the geometry structure. (interdisciplinary physics and related areas of science and technology)

  1. Algebraic software analysis and embedded simulation of a driving robot

    NARCIS (Netherlands)

    Merkx, L.L.F.; Duringhof, H.M.; Cuijpers, P.J.L.

    2007-01-01

    At TNO Automotive the Generic Driving Actuator (GDA) is developed. The GDA is a device capable of driving a vehicle fully automatically using the same interface as a human driver does. In this paper, the design of the GDA is discussed. The software and hardware of the GDA and its effect on vehicle

  2. A device for the hydraulic control of nuclear reactor control rods

    International Nuclear Information System (INIS)

    Frisch, Erling; Frisch, D.R.; Andrews, H.N.

    1974-01-01

    A device for driving and locking the control rods of a nuclear reactor. This device comprises a hydraulic driving piston mounted in a cylinder provided with a construction for absorbing shocks. The piston is provided, at is extremity, with a locking device adapted to engage a stationary lock, it being possible to control the latter for freeing said piston locking device; with such an arrangement, the control rod is normally maintained in position, and it can be freed only by a positive signal. Moreover, the control rod movements are slowed down, so as to prevent the gripping device from being damaged. This device can be used in the nuclear industry [fr

  3. Simulating autonomous driving styles: Accelerations for three road profiles

    Directory of Open Access Journals (Sweden)

    Karjanto Juffrizal

    2017-01-01

    Full Text Available This paper presents a new experimental approach to simulate projected autonomous driving styles based on the accelerations at three road profiles. This study was focused on the determination of ranges of accelerations in triaxial direction to simulate the autonomous driving experience. A special device, known as the Automatic Acceleration and Data controller (AUTOAccD, has been developed to guide the designated driver to accomplish the selected accelerations based on the road profiles and the intended driving styles namely assertive, defensive and light rail transit (LRT. Experimental investigations have been carried out at three different road profiles (junction, speed hump, and corner with two designated drivers with five trials on each condition. A driving style with the accelerations of LRT has also been included in this study as it is significant to the present methodology because the autonomous car is predicted to accelerate like an LRT, in such a way that it enables the users to conduct activities such as working on a laptop, using personal devices or eating and drinking while travelling. The results demonstrated that 92 out of 110 trials of the intended accelerations for autonomous driving styles could be achieved and simulated on the real road by the designated drivers. The differences between the two designated drivers were negligible, and the rates of succeeding in realizing the intended accelerations were high. The present approach in simulating autonomous driving styles focusing on accelerations can be used as a tool for experimental setup involving autonomous driving experience and acceptance.

  4. Ultrasonic viewing device

    International Nuclear Information System (INIS)

    Ito, Juro.

    1979-01-01

    Purpose: To improve the safety of reactor operation by enabling to detect the states and positions of fuel assemblies over a wide range with a set of ultrasonic viewing device comprising a rotatable ultrasonic transmitter-receiver and a reflector mounted with an adjustable angle. Constitution: A driving portion for a ultrasonic viewing device is provided to a rotary plug closing the opening of a reactor vessel and a guide pipe suspending below the coolant level is provided to the driving portion. An ultrasonic transmitter-receiver is provided at the end of the holder tube in the guide pipe. A reflector is provided at the upper position of the reactor core so as to correspond to the ultrasonic transmitter-receiver. The ultrasonic transmitter-receiver, positioned by the driving portion, performs horizontal movement for scanning the entire surface of the top of the reactor core, as well as vertical movement covering the gap between the upper mechanism on the reactor and the reactor core, whereby the confirmation for the separation of the control rod and the detection for the states of the reactor core can be conducted by the reflection waves from the reflector. (Moriyama, K.)

  5. Assessment of exposure to manganese in welding operations during the assembly of heavy excavation machinery accessories.

    Science.gov (United States)

    Smargiassi, A; Baldwin, M; Savard, S; Kennedy, G; Mergler, D; Zayed, J

    2000-10-01

    Welder exposure to metals in various industrial sectors is poorly characterized. We had the opportunity to carry out an exploratory study to characterize manganese exposure in welding operations in a recently established Quebec factory that assembled accessories for heavy excavation machinery. Ten workers were sampled for total manganese for at least two consecutive days out of three followed by two consecutive days for respirable manganese (with a size selective sampler with a median cut-off of 4 microns), during a typical week in the summer of 1998. Parts being welded were characterized as large or small. Small parts were those being welded on tables during subassembly. Workers were divided into two groups according to the parts they were welding. Seventy-eight percent of the total manganese exposure levels of welding operations during the assembly of large accessories of heavy excavation machinery exceeded the manganese American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) of 0.20 mg/m3 (GM 0.24 mg/m3, n = 14) while none exceeded the TLV during the assembly of small pieces (GM 0.06 mg/m3, n = 8). Welding operations during the assembly of large heavy excavation machinery accessories may pose a significant health hazard. Considering the importance of task-related variables affecting exposure among workers, further studies are needed to better characterize exposure determinants of welding operations during the assembly of heavy excavation machinery accessories.

  6. Accessory mental foramen: A rare anatomical variation detected by cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Marianna Guanaes Gomes; De Faro Valverde, Ludmila; Vidal, Manuela Torres Andion; Crusoe-Rebello, Ieda Margarida [Dept. of Oral Radiology, School of Dentistry, Federal University of Bahia, Salvador (Brazil)

    2015-03-15

    The mental foramen is a bilateral opening in the vestibular portion of the mandible through which nerve endings, such as the mental nerve, emerge. In general, the mental foramen is located between the lower premolars. This region is a common area for the placement of dental implants. It is very important to identify anatomical variations in presurgical imaging exams since damage to neurovascular bundles may have a direct influence on treatment success. In the hemimandible, the mental foramen normally appears as a single structure, but there are some rare reports on the presence and number of anatomical variations; these variations may include accessory foramina. The present report describes the presence of accessory mental foramina in the right mandible, as detected by cone-beam computed tomography before dental implant placement.

  7. Control system of fuel transporting device

    International Nuclear Information System (INIS)

    Yokota, Minoru.

    1981-01-01

    Purpose: To effectively avoid an obstacle in a fuel transporting device by reading the outputs of absolute position detectors mounted on movable trucks, controlling the movements of the trucks, and thereby smoothly and accurately positioning the fuel transporting device at predetermined position and providing a contact detector thereat. Method: The outputs from absolute position detectors which are mounted on a longitudinally movable truck and a laterally movable truck are input to an input/output control circuit. The input/output control circuit serves to compare, the position a fuel transporting device is to be moved to, with the present position on the basis of said input detection signal and a command signal from an operator console, to calculate the amount of movement to be driven, to produce an operation signal therefor to a control panel, and to drive and control the drive motors which are respectively mounted on the trucks for the fuel transfer device. On the other hand, in case that the transfer device comes into contact with an obstacle, the contact detector will immediately operate to produce a stop command through the control panel to the transporting device, and avoid a collision with the obstacle. (Yoshino, Y.)

  8. Detection circuit of solenoid valve operation and control rod drive mechanism utilizing the circuit

    International Nuclear Information System (INIS)

    Ono, Takehiko.

    1976-01-01

    Object: To detect the operation of a plunger and detect opening and closing operations of a solenoid valve driving device due to change in impedance of a coil for driving the solenoid valve to judge normality and abnormality of the solenoid valve, thereby increasing reliance and safety of drive and control apparatus of control rods. Structure: An arrangement comprises a drive and operation detector section wherein the operation of a solenoid driving device for controlling power supply to a coil for driving the solenoid valve to control opening and closing of the solenoid valve, and a plunger operation detector section for detecting change in impedance of the drive coil to detect that the plunger of the solenoid valve is either in the opening direction or closing direction, whereby a predetermined low voltage such as not to activate the solenoid valve even when the solenoid valve is open or closed is applied to detect a current flowing into the coil at that time, thus detecting an operating state of the plunger. (Yoshino, Y.)

  9. Monitoring device for withdrawing control rods

    International Nuclear Information System (INIS)

    Higashigawa, Yuichi.

    1985-01-01

    Purpose: To improve the sensitivity and the responsivity to an equivalent extent to those in the case where local power range monitors are densely arranged near each of the control rods, with no actual but pseudo increase of the number of local power range monitors. Constitution: The monitor arrangement is patterned by utilizing the symmetricity of the reactor core and stored in a monitor designating device. The symmetricity of control rods to be selected and withdrawn by an operator is judged by a control rod symmetry monitoring device, while the symmetricity of the withdrawn control rods is judged by a control rod withdrawal state monitoring device. Then, only when both of the devices judge the symmetricity, the control rods are subjected to gang driving by the control rod drive mechanisms. In this way, monitoring at a high sensitivity and responsivity is enabled with no increase for the number of monitors. (Yoshino, Y.)

  10. Preparation and Dielectric Properties of SiC/LSR Nanocomposites for Insulation of High Voltage Direct Current Cable Accessories.

    Science.gov (United States)

    Shang, Nanqiang; Chen, Qingguo; Wei, Xinzhe

    2018-03-08

    The conductivity mismatch in the composite insulation of high voltage direct current (HVDC) cable accessories causes electric field distribution distortion and even insulation breakdown. Therefore, a liquid silicone rubber (LSR) filled with SiC nanoparticles is prepared for the insulation of cable accessories. The micro-morphology of the SiC/LSR nanocomposites is observed by scanning electron microscopy, and their trap parameters are characterized using thermal stimulated current (TSC) tests. Moreover, the dielectric properties of SiC/LSR nanocomposites with different SiC concentrations are tested. The results show that the 3 wt % SiC/LSR sample has the best nonlinear conductivity, more than one order of magnitude higher than that of pure LSR with improved temperature and nonlinear conductivity coefficients. The relative permittivity increased 0.2 and dielectric loss factor increased 0.003, while its breakdown strength decreased 5 kV/mm compared to those of pure LSR. Moreover, the TSC results indicate the introduction of SiC nanoparticles reduced the trap level and trap density. Furthermore, the SiC nanoparticles filling significantly increased the sensitivity of LSR to electric field stress and temperature changes, enhancing the conductivity and electric field distribution within the HVDC cable accessories, thus improving the reliability of the HVDC cable accessories.

  11. Nipple adenoma arising from axillary accessory breast: a case report

    Directory of Open Access Journals (Sweden)

    Shioi Yoshihiro

    2012-11-01

    Full Text Available Abstract Nipple adenoma is a relatively rare benign breast neoplasm, and cases of the disease arising from the axillary accessory breast have very seldom been reported in the English literature. We report a case of nipple adenoma arising from axillary accessory breast including clinical and pathological findings. An 82-year-old woman presented with the complaint of a small painful mass in the right axilla. Physical examination confirmed a well-defined eczematous crusted mass that was 8 mm in size. The diagnosis of nipple adenoma was made from an excisional specimen on the basis of characteristic histological findings. Microscopic structural features included a compact proliferation of small tubules lined by epithelial and myoepithelial cells, and the merging of glandular epithelial cells of the adenoma into squamous epithelial cells in the superficial epidermal layer. Because clinically nipple adenoma may resemble Paget’s disease and pathologically can be misinterpreted as tubular carcinoma, the correct identification of nipple adenoma is an important factor in the differential diagnosis for axillary tumor neoplasms. Virtual slides The virtual slide(s for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1186821489769063

  12. Evaluation of accessory cell heterogeneity. I. Differential accessory cell requirement for T helper cell activation and for T-B cooperation.

    Science.gov (United States)

    Ramila, G; Studer, S; Kennedy, M; Sklenar, I; Erb, P

    1985-01-01

    Several Ia+ tumor cell lines and peritoneal exudate macrophages were tested as accessory cells (AC) for the activation of antigen-specific T cells and for T-B cooperation. The macrophages and all the Ia+ tumor lines tested induced the release of lymphokines from T cells in a major histocompatibility complex (MHC)-restricted fashion and reconstituted the antibody responses of AC-depleted spleen cells or of purified T and B cells. However, only the normal macrophages but none of the tumor lines induced carrier-specific T helper (Th) cells which help B cells for specific antihapten antibody responses by linked recognition. For T-B cooperation accessory cells were also required, but in contrast to Th cell activation any type of Ia+ AC (e.g. macrophage or tumor line) was effective. Strong MHC-restriction between the lymphocytes and the AC was seen if antigen-pulsed AC were added into the AC-depleted T-B cooperation cultures. If the AC and antigen were concomitantly added to the AC-depleted T-B cultures, MHC-restriction was less obvious. Concanavalin A supernatant reconstituted the response of AC-depleted T-B cultures provided antigen-specific Th cells and the hapten-carrier conjugate were present. If, however, tumor line-activated T cells were added instead of macrophage-induced Th cells, no cooperation with B cells took place even in the presence of Con A supernatant. The results obtained demonstrate a differential AC requirement for the induction of Th cells depending on the differentiation stage of the Th cells.

  13. REDUNDANT ELECTRIC MOTOR DRIVE CONTROL UNIT DESIGN USING AUTOMATA-BASED APPROACH

    Directory of Open Access Journals (Sweden)

    Yuri Yu. Yankin

    2014-11-01

    Full Text Available Implementation of redundant unit for motor drive control based on programmable logic devices is discussed. Continuous redundancy method is used. As compared to segregated standby redundancy and whole system standby redundancy, such method provides preservation of all unit functions in case of redundancy and gives the possibility for continuous monitoring of major and redundant elements. Example of that unit is given. Electric motor drive control channel block diagram contains two control units – the major and redundant; it also contains four power supply units. Control units programming was carried out using automata-based approach. Electric motor drive control channel model was developed; it provides complex simulation of control state-machine and power converter. Through visibility and hierarchy of finite state machines debug time was shortened as compared to traditional programming. Control state-machine description using hardware description language is required for its synthesis with FPGA-devices vendor design software. This description was generated automatically by MATLAB software package. To verify results two prototype control units, two prototype power supply units, and device mock-up were developed and manufactured. Units were installed in the device mock-up. Prototype units were created in accordance with requirements claimed to deliverable hardware. Control channel simulation and tests results in the perfect state and during imitation of major element fault are presented. Automata-based approach made it possible to observe and debug control state-machine transitions during simulation of transient processes, occurring at imitation of faults. Results of this work can be used in development of fault tolerant electric motor drive control channels.

  14. Superconductor devices useful for disk drives and the like

    International Nuclear Information System (INIS)

    Barnes, F.S.

    1989-01-01

    This patent describes an apparatus for exchanging information with a circular media and which includes a drive mechanism for radially positioning a head relative to the media with the head including structure for imparting information to the media, for detecting information on the media, or both, comprising: an arm having at least one head attached thereto wherein the head is capable of interchanging information with the media; and bearing means for suspending the arm, the bearing means including a superconductor layer element, a magnetic field source element and means mounting one of the elements on the arm and the other the element in interfacing relationship to the one of the elements so that the interfacing relationship is maintained throughout the radial travel of the arm. A drive for exchanging information between a circular media mounted on a spindle and a head comprising an elongated arm having the head attached thereto and a layer of superconductor material on one side thereof, the arm being radially positionable over the surface of the circular media, an annular magnet means in peripheral relation to the circular media and oriented to direct a magnetic field towards the arm superconductor layer for maintaining a relatively constant spacing between the arm and the media throughout the radial travel of the arm relative to the circular media

  15. Comparison of electric drives for road vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Bader, C; Stephan, W [Deutsche Automobilgesellschaft m.b.H., Esslingen (Germany, F.R.)

    1977-01-01

    The low energy-storage capacity of the electrolytic energy-storage apparatus available at the moment limits the practical use of electric vehicles to meeting the requirements for restricted areas. But in this field of application, conversion from drive with internal combustion engine to electric drive can be considered only if a reduction of costs is achieved with electric drive. From the wide range of possible drive units the most suitable is found to be the dc squirrelcage motor the speed of which is controlled by field weakening. In the case of a motor with conventional design, the controllable drive range is limited to about 1 : 3, so that generally additional measures are required for extending the drive range. But if the motor is fitted with a compensation winding, field weakening to give a controlled speed range of 1 : 8 can be obtained. To evaluate the different drive units under consideration use is made of the acceleration when, according to the drive system, advantages are obtained from the point of view of energy consumption with disadvantages in acceleration time, and vice versa. By using vehicles proven in practice with different drive systems, either with hydrodynamic transducer and battery switchover, or else with changeover gear and mechanical clutch, the overall construction of the different control and protective arrangements are demonstrated. It is then found that the extra cost of regulation in the case of automatic drive operation is partly compensated by the additional protective devices which are required to limit the effects of any incorrect operations with a manually-operated drive.

  16. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  17. A Closed-Loop Smart Control System Driving RGB Light Emitting Diodes

    KAUST Repository

    Al-Saggaf, Abeer

    2015-05-01

    The demand for control systems that are highly capable of driving solid-state optoelectronic devices has significantly increased with the advancement of their efficiency and elevation of their current consumption. This work presents a closed-loop control system that is based on a microcontroller embedded system capable of driving high power optoelectronic devices. In this version of the system, the device in the center of control is a high-power red, green, and blue light emitting diode package. The system features a graphical user interface, namely an Android mobile phone application, in which the user can easily use to vary the light color and intensity of the light-emitting device wirelessly via Bluetooth. Included in the system is a feedback mechanism constituted by a red, green, and blue color sensor through which the user can use to observe feedback color information about the emitted light. The system has many commercial application including in-door lighting and research application including plant agriculture research fields.

  18. A Closed-Loop Smart Control System Driving RGB Light Emitting Diodes

    KAUST Repository

    Al-Saggaf, Abeer

    2015-01-01

    The demand for control systems that are highly capable of driving solid-state optoelectronic devices has significantly increased with the advancement of their efficiency and elevation of their current consumption. This work presents a closed-loop control system that is based on a microcontroller embedded system capable of driving high power optoelectronic devices. In this version of the system, the device in the center of control is a high-power red, green, and blue light emitting diode package. The system features a graphical user interface, namely an Android mobile phone application, in which the user can easily use to vary the light color and intensity of the light-emitting device wirelessly via Bluetooth. Included in the system is a feedback mechanism constituted by a red, green, and blue color sensor through which the user can use to observe feedback color information about the emitted light. The system has many commercial application including in-door lighting and research application including plant agriculture research fields.

  19. Accessory minerals and subduction zone metasomatism: a geochemical comparison of two mélanges (Washington and California, U.S.A.)

    Science.gov (United States)

    Sorensen, Sorena S.; Grossman, Jeffrey N.

    1993-01-01

    The ability of a subducted slab or subducted sediment to contribute many incompatible trace elements to arc source regions may depend on the stabilities of accessory minerals within these rocks, which can only be studied indirectly. In contrast, the role of accessory minerals in lower-T and -P metasomatic processes within paleo-subduction zones can be studied directly in subduction-zone metamorphic terranes.

  20. Bilateral axillary masses mimicking as accessory breast with multiple fibroadenoma and bilateral gigantomastia in HIV-positive patient.

    Science.gov (United States)

    Singh, Saumya; Mishra, Anand K; Tewari, S; Kumar, Sanjeev

    2013-06-24

    Accessory breast is a rare entity that can present as asymptomatic masses or can cause symptoms like heaviness, pain, restriction of arm movement and limitation in daily pursuits with allied apprehension and anxiety for the patient. We present a case of bilateral axillary masses mimicking as accessory breast with multiple fibroadenoma in a 28 years, nulliparous, Indian woman who is HIV positive, which proves to be a diagnostic dilemma. Excisional biopsy was diagnostic. The rarity of such cases imposes challenges on the management in terms of diagnosis, prognosis and therapeutic options.

  1. Accessory ossicles and sesamoid bones of the ankle and foot: imaging findings, clinical significance and differential diagnosis

    International Nuclear Information System (INIS)

    Mellado, J.M.; Ramos, A.; Salvado, E.; Camins, A.; Sauri, A.; Danus, M.

    2003-01-01

    Accessory ossicles and sesamoid bones are frequent findings in routine radiographs of the ankle and foot. They are commonly considered fortuitous and unrelated to the patient's complaint; however, they may eventually cause painful syndromes or degenerative changes in response to overuse and trauma. They may also suffer or simulate fractures. Our aim was to review, illustrate and discuss the imaging findings of some of the more frequent accessory ossicles and sesamoid bones of the ankle and foot region, with particular emphasis on those that may be of clinical significance or simulate fractures. (orig.)

  2. Equipment for measuring torque and diagnostic data on control rod drive of nuclear reactor

    International Nuclear Information System (INIS)

    Simka, K.; Sneberger, J.; Tater, V.

    1991-01-01

    The equipment comprises an electric drive, a measuring unit and a device securing the movable parts of the drive. It can be used to measure the torque and diagnostic data of the control facility drive with the desired accuracy without having to dismantle the facility during decoupling or coupling the control component to the drive, during programming the movable parts in the transporting position. (Z.S.). 1 fig

  3. Study of lower hybrid current drive system in tokamak fusion devices

    International Nuclear Information System (INIS)

    Maebara, Sunao

    2001-01-01

    This report describes R and D of a high-power klystron, RF vacuum window, low-outgassing antenna and a front module for a plasma-facing antenna aiming the 5 GHz Lower Hybrid Current Drive (LHCD) system for the next Tokamak Fusion Device. 5 GHz klystron with a low-perveances of 0.7 μP is designed for a high-power and a high-efficiency, the output-power of 715 kW and the efficiency of 63%, which are beyond the conventional design scaling of 450 kW-45%, are performed using the prototype klystron which operates at the pulse duration of 15 μsec. A new pillbox window, which has an oversized length in both the axial and the radial direction, are designed to reduce the RF power density and the electric field strength at the ceramics. It is evaluated that the power capability by cooling edge of ceramics is 1 MW with continuous-wave operation. The antenna module using Dispersion Strengthened Copper which combines high mechanical property up to 500degC with high thermal conductivity, are developed for a low-outgassing antenna in a steady state operation. It is found that the outgassing rate is in the lower range of 4x10 -6 Pam 3 /sm 2 at the module temperature of 300degC, which requires no active vacuum pumping of the LHCD antenna. A front module using Carbon Fiber Composite (CFC) are fabricated and tested for a plasma facing antenna which has a high heat-resistive. Stationary operation of the CFC module with water cooling is performed at the RF power of 46 MWm -2 (about 2 times higher than the design value) during 1000 sec, it is found that the outgassing rate is less than 10 -5 Pam 3 /sm 2 which is low enough for an antenna material. (author)

  4. Nuclear fuel rack lateral support and preload device

    International Nuclear Information System (INIS)

    Knight, C.B.

    1979-01-01

    A lateral support device for a nuclear fuel rack is described. It is vertically positioned within a walled enclosure which provides a preload to maintain effective support. The device includes a scissors-jack which is mounted so that the drive screw is vertical. Upon rotation of the drive screw the jack expands horizontally, seating a load pad against a vertical wall. The load pad is affixed to the jack by an arm having a stack of spring washers which compress between the pad and the jack, thereby applying a selected preload

  5. Modelling and Design of Active Thermal Controls for Power Electronics of Motor Drive Applications

    DEFF Research Database (Denmark)

    Vernica, Ionut; Blaabjerg, Frede; Ma, Ke

    2017-01-01

    of active thermal control methods for the power devices of a motor drive application. The motor drive system together with the thermal cycling of the power devices have been modelled, and adverse temperature swings could be noticed during the start-up and deceleration periods of the motor. Based...... on the electrical response of the system, the junction temperature of the semiconductor devices is estimated, and consequently three active thermal control methods are proposed and practically designed with respect to the following parameters: switching frequency, deceleration slope and modulation technique....... Finally, experimental results are provided in order to validate the effectiveness of the proposed control methods....

  6. Sodium aerosol recovering device

    International Nuclear Information System (INIS)

    Fujimori, Koji; Ueda, Mitsuo; Tanaka, Kazuhisa.

    1997-01-01

    A main body of a recovering device is disposed in a sodium cooled reactor or a sodium cooled test device. Air containing sodium aerosol is sucked into the main body of the recovering device by a recycling fan and introduced to a multi-staged metal mesh filter portion. The air about against each of the metal mesh filters, and the sodium aerosol in the air is collected. The air having a reduced sodium aerosol concentration circulates passing through a recycling fan and pipelines to form a circulation air streams. Sodium aerosol deposited on each of the metal mesh filters is scraped off periodically by a scraper driving device to prevent clogging of each of the metal filters. (I.N.)

  7. Giant magneto-resistance devices

    CERN Document Server

    Hirota, Eiichi; Inomata, Koichiro

    2002-01-01

    This book deals with the application of giant magneto-resistance (GMR) effects to electronic devices. It will appeal to engineers and graduate students in the fields of electronic devices and materials. The main subjects are magnetic sensors with high resolution and magnetic read heads with high sensitivity, required for hard-disk drives with recording densities of several gigabytes. Another important subject is novel magnetic random-access memories (MRAM) with non-volatile non-destructive and radiation-resistant characteristics. Other topics include future GMR devices based on bipolar spin transistors, spin field-effect transistors (FETs) and double-tunnel junctions.

  8. Semiconductor-based, large-area, flexible, electronic devices on {110} oriented substrates

    Science.gov (United States)

    Goyal, Amit

    2014-08-05

    Novel articles and methods to fabricate the same resulting in flexible, oriented, semiconductor-based, electronic devices on {110} textured substrates are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  9. [100] or [110] aligned, semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit

    2015-03-24

    Novel articles and methods to fabricate the same resulting in flexible, large-area, [100] or [110] textured, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  10. Teens' distracted driving behavior: Prevalence and predictors.

    Science.gov (United States)

    Gershon, Pnina; Zhu, Chunming; Klauer, Sheila G; Dingus, Tom; Simons-Morton, Bruce

    2017-12-01

    Teen drivers' over-involvement in crashes has been attributed to a variety of factors, including distracted driving. With the rapid development of in-vehicle systems and portable electronic devices, the burden associated with distracted driving is expected to increase. The current study identifies predictors of secondary task engagement among teenage drivers and provides basis for interventions to reduce distracted driving behavior. We described the prevalence of secondary tasks by type and driving conditions and evaluated the associations between the prevalence of secondary task engagement, driving conditions, and selected psychosocial factors. The private vehicles of 83 newly-licensed teenage drivers were equipped with Data Acquisition Systems (DAS), which documented driving performance measures, including secondary task engagement and driving environment characteristics. Surveys administered at licensure provided psychosocial measures. Overall, teens engaged in a potentially distracting secondary task in 58% of sampled road clips. The most prevalent types of secondary tasks were interaction with a passenger, talking/singing (no passenger), external distraction, and texting/dialing the cell phone. Secondary task engagement was more prevalent among those with primary vehicle access and when driving alone. Social norms, friends' risky driving behaviors, and parental limitations were significantly associated with secondary task prevalence. In contrast, environmental attributes, including lighting and road surface conditions, were not associated with teens' engagement in secondary tasks. Our findings indicated that teens engaged in secondary tasks frequently and poorly regulate their driving behavior relative to environmental conditions. Practical applications: Peer and parent influences on secondary task engagement provide valuable objectives for countermeasures to reduce distracted driving among teenage drivers. Copyright © 2017 National Safety Council and

  11. Towards autonomous lab-on-a-chip devices for cell phone biosensing.

    Science.gov (United States)

    Comina, Germán; Suska, Anke; Filippini, Daniel

    2016-03-15

    Modern cell phones are a ubiquitous resource with a residual capacity to accommodate chemical sensing and biosensing capabilities. From the different approaches explored to capitalize on such resource, the use of autonomous disposable lab-on-a-chip (LOC) devices-conceived as only accessories to complement cell phones-underscores the possibility to entirely retain cell phones' ubiquity for distributed biosensing. The technology and principles exploited for autonomous LOC devices are here selected and reviewed focusing on their potential to serve cell phone readout configurations. Together with this requirement, the central aspects of cell phones' resources that determine their potential for analytical detection are examined. The conversion of these LOC concepts into universal architectures that are readable on unaccessorized phones is discussed within this context. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Performance Improvement of Sensorless Vector Control for Matrix Converter Drives Using PQR Transformation

    DEFF Research Database (Denmark)

    Lee, Kyo-Beum; Blaabjerg, Frede

    2005-01-01

    This paper presents a new method to improve sensorless performance of matrix converter drives using PQR power transformation. The non-linearity of matrix converter drives such as commutation delay, turn-on and turn-off time of switching device, and on-state switching device voltage drop is modelled...... using PQR transformation and compensated using a reference current control scheme. To eliminate the input current distortion due to the input voltage unbalance, a simple method using PQR transformation is also proposed. The proposed compensation method is applied for high performance induction motor...

  13. Efficiency trends in electric machines and drives

    International Nuclear Information System (INIS)

    Mecrow, B.C.; Jack, A.G.

    2008-01-01

    Almost all electricity in the UK is generated by rotating electrical generators, and approximately half of it is used to drive electrical motors. This means that efficiency improvements to electrical machines can have a very large impact on energy consumption. The key challenges to increased efficiency in systems driven by electrical machines lie in three areas: to extend the application of variable-speed electric drives into new areas through reduction of power electronic and control costs; to integrate the drive and the driven load to maximise system efficiency; and to increase the efficiency of the electrical drive itself. In the short to medium term, efficiency gains within electrical machines will result from the development of new materials and construction techniques. Approximately a quarter of new electrical machines are driven by variable-speed drives. These are a less mature product than electrical machines and should see larger efficiency gains over the next 50 years. Advances will occur, with new types of power electronic devices that reduce switching and conduction loss. With variable-speed drives, there is complete freedom to vary the speed of the driven load. Replacing fixed-speed machines with variable-speed drives for a high proportion of industrial loads could mean a 15-30% energy saving. This could save the UK 15 billion kWh of electricity per year which, when combined with motor and drive efficiency gains, would amount to a total annual saving of 24 billion kWh

  14. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  15. An introduction to direct access storage devices

    CERN Document Server

    Sierra, Hugh M

    2012-01-01

    This book presents an exposition of the technology, design, organization, and structure of direct access storage devices (disk drives). It includes a discussion of the evolution of the technology (magnetic recording) and an assessment of other storage technologies, including optical recording. Examples of codes used in past implementations of disk drives as well as an application of disk drive usage dictated by reliability considerations are also included. The presentation assumes a minimum knowledge of magnetic recording, servomechanism design, and coding.

  16. Terminal phalangeal accessory ossification center of the thumb: an additional radiographic finding in Larsen syndrome

    International Nuclear Information System (INIS)

    Alanay, Yasemin; Utine, Gulen E.; Tuncbilek, Ergul; Lachman, Ralph S.; Krakow, Deborah

    2006-01-01

    Larsen syndrome is an autosomal-dominant disorder characterized by multiple joint dislocations, vertebral anomalies and dysmorphic facies. Both autosomal-dominant and autosomal-recessive forms of the disorder have been proposed. Individuals with autosomal-dominant Larsen syndrome have characteristic ''cylindrical-shape'' thumbs caused by broad, shortened phalanges. Autosomal-dominant Larsen syndrome results from heterozygosity for mutations in filamin B, a cytoskeletal protein involved in multicellular processes. We report here a patient with a duplicated or accessory distal thumb phalanx and multiple large joint dislocations who was shown to be heterozygous for a filamin B mutation predicting the amino acid substitution G1691S. This adds a new radiographic finding, duplicated or accessory distal phalanx, to the radiographic abnormalities seen in this rare dominant disorder. (orig.)

  17. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  18. 26 CFR 48.4063-2 - Tax-free sales of parts or accessories sold for resale on or in connection with the first retail...

    Science.gov (United States)

    2010-04-01

    ... must be adhered to in substance. Exemption Certificate (For use by ultimate purchaser who purchase... furnished to vendee. A vendor (including the manufacturer) selling light-duty truck parts and accessories... vendor. A manufacturer or vendor selling light-duty truck parts or accessories tax free under section...

  19. Power Devices Loading in Multilevel Converters for 10 MW Wind Turbines

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede; Xu, Dehong

    2011-01-01

    Several promising multilevel converter solutions for 10 MW wind turbines using permanent magnet synchronous generators are proposed, designed and compared both with one-stage gear-box drive and direct drive systems. The current and loss distributions, as well as the utilization of power devices......-level NeutralPoint-Clamped topology with both the direct-drive and one-stage gear box drive systems....

  20. THE STUDY OF SELF-BALANCED POTATO SORTING MACHINE WITH LINEAR INDUCTION DRIVE

    OpenAIRE

    Linenko A. V.; Baynazarov V. G.; Kamalov T. I.

    2016-01-01

    In the article we have considered the self-balanced potato sorting machine differing from existing designs of self-balanced potato sorting machines with an oscillatory electric drive. That drive uses a linear induction motor. As the counterbalancing device, the method of the duplicating mechanism is applied. The duplicating mechanism is a specular reflection of the main working body, and also participates in technological process. Its application in the drive of machine allows not only to inc...

  1. Ventricular Dyssynchrony and Function Improve following Catheter Ablation of Nonseptal Accessory Pathways in Children

    Directory of Open Access Journals (Sweden)

    Sylvia Abadir

    2013-01-01

    Full Text Available Introduction. Paradoxical or hypokinetic interventricular septal motion has been described in patients with septal or paraseptal accessory pathways. Data regarding nonseptal pathways is limited. Methods and Results. We quantified left ventricular dyssynchrony and function in 16 consecutive children, 14.2±3.7 years, weighing 53 ± 17 kg, prior to and following catheter ablation of bidirectional septal (N=6 and nonseptal (N=10 accessory pathways. Following ablation, the left ventricular ejection fraction increased by 4.9±2.1% (P=0.038 from a baseline value of 57.0%±7.8%. By tissue Doppler imaging, the interval between QRS onset and peak systolic velocity (Ts decreased from a median of 33.0 ms to 18.0 ms (P=0.013. The left ventricular ejection fraction increased to a greater extent following catheter ablation of nonseptal (5.9%±2.6%, P=0.023 versus septal (2.5%±4.1%, P=0.461 pathways. The four patients with an ejection fraction 50% after ablation. Similarly, the improvement in dyssynchrony was more marked in patients with nonseptal versus septal pathways (difference between septal and lateral wall motion delay before and after ablation 20.6±7.1 ms (P=0.015 versus 1.4±11.4 ms (P=0.655. Conclusion. Left ventricular systolic function and dyssynchrony improve after ablation of antegrade-conducting accessory pathways in children, with more pronounced changes noted for nonseptal pathways.

  2. Evaluation of accessory cell heterogeneity. III. Role of dendritic cells in the in vitro activation of the antibody response to soluble antigens.

    Science.gov (United States)

    Erb, P; Ramila, G; Sklenar, I; Kennedy, M; Sunshine, G H

    1985-05-01

    Dendritic cells and macrophages obtained from spleen and peritoneal exudate were tested as accessory cells for the activation of lymphokine production by T cells, for supporting T-B cooperation and for the induction of antigen-specific T helper cells. Dendritic cells as well as macrophages were able to activate T cells for interleukin-2 secretion and functioned as accessory cells in T-B cooperation, but only macrophages induced T helper cells, which cooperate with B cells by a linked recognition interaction, to soluble antigens. Dendritic cell- and antigen-activated T cells also did not help B cells in the presence of Con A supernatants which contained various T cell- and B cell-stimulatory factors. The failure of dendritic cells to differentiate memory into functional T helper cells, but their efficient accessory cell function in T-B cooperation, where functional T helper cells are already present, can be best explained by a differential accessory cell requirement for T helper cell activation dependent on the differentiation stage of the T helper cell.

  3. Case report 376: Accessory (anomalous) soleus muscle

    International Nuclear Information System (INIS)

    Apple, J.S.; Khoury, M.B.; Martinez, S.; Nunley, J.A.

    1986-01-01

    In summary, a case has been presented of a 24-year-old woman who developed pain in the left lower extremity while jogging. Physical examination showed a soft, palpable mass medial and anterior to the Achilles tendon in the left lower extremity. Although a lipoma was suspected, plain films and CT studies indicated clearly that the mass was not of fatty density. In fact, the density of the mass was equivalent to adjacent muscles. The mass itself was lying in the soft tissues of the left ankle tissue. An open biopsy showed a normal muscle which represented an accessory soleus muscle - a muscle known to be anomalous on accoasion and reported as being symptomatic or asymptomatic in different individuals. (orig./SHA)

  4. Sclerotic fibroma (storiform collagenoma)-like stroma in a fibroadenoma of axillary accessory breast tissue.

    Science.gov (United States)

    Val-Bernal, José Fernando; González-Vela, María Carmen; De Grado, Mauricio; Garijo, María Francisca

    2012-08-01

    Accessory breast tissue is a subcutaneous remnant persisting after normal embryological development of the breast. It occurs most frequently in the axilla. Fibroadenomas in axillary breast tissue are rare. We report the case of a 29-year-old female patient who presented a fibroadenoma arising in the accessory breast tissue of the right axillary fossa. The neoplasm showed foci of sclerotic fibroma-like stroma. The patient had no signs of Cowden's syndrome. To the best of our knowledge, a lesion of this kind has not been previously reported. This stromal change suggests an uncommon involutional phase of the fibroadenoma with production of sclerotic and hypocellular collagen. The lesion should be differentiated from extraneural perineuroma, from the changes in fibroadenomas in Cowden's syndrome, from sclerosing lobular hyperplasia (fibroadenomatoid mastopathy) and from pseudoangiomatous stromal hyperplasia. Copyright © 2012 John Wiley & Sons A/S.

  5. Neoclassical effects on RF current drive in tokamaks

    International Nuclear Information System (INIS)

    Yoshioka, K.; Antonsen, T.M. Jr.

    1986-01-01

    Neoclassical effects on RF current drive which arise because of the inhomogeneity of the magnetic field in tokamak devices are analysed. A bounce averaged 2-D Fokker-Planck equation is derived from the drift kinetic equation and is solved numerically. The model features current drive due to a strong RF wave field. The efficiency of current drive by electron cyclotron waves is significantly reduced when the waves are absorbed at the low magnetic field side of a given flux surface, whereas the efficiency remains at the same level as in the homogeneous ideal plasma when the waves are absorbed at the high field side. The efficiency of current drive by fast waves (compressional Alfven waves) with low phase velocity (vsub(parallel)/vsub(th)<1) is significantly degraded by neoclassical effects, no matter where the wave is absorbed, and the applicability of this wave seems, therefore, to be doubtful. (author)

  6. Method and device for ion mobility separations

    Science.gov (United States)

    Ibrahim, Yehia M.; Garimella, Sandilya V. B.; Smith, Richard D.

    2017-07-11

    Methods and devices for ion separations or manipulations in gas phase are disclosed. The device includes a single non-planar surface. Arrays of electrodes are coupled to the surface. A combination of RF and DC voltages are applied to the arrays of electrodes to create confining and driving fields that move ions through the device. The DC voltages are static DC voltages or time-dependent DC potentials or waveforms.

  7. GSM accessories now available from the CERN Stores

    CERN Multimedia

    Labo Telecom

    2001-01-01

    As of 1st October you can order and receive GSM accessories from the CERN stores like any other article. The CERN stores also manage GSM telephones but, for technical reasons, only the Labo Telecom shop (Building 31, Room S026) is able to make the standard sales, repairs and exchanges for authorised persons with a CERN subscription. Labo Telecom will thus become a specialist shop, open from 11 a.m. to 12 a.m., and will apply the usual rules and authorisation procedures of the stores. The paper form for requests for GSM subscriptions is being computerized and will be available on EDH in the near future.

  8. Creation of electromechanical device for electric vehicle traction

    Directory of Open Access Journals (Sweden)

    Денис Юрьевич Зубенко

    2016-10-01

    Full Text Available The problems of creation of electromechanical device for electric vehicle traction are considered in the article. The aim of creation this design are the replacement of the internal combustion engine on electromechanical device. For this electromechanical device are constructed model, which describe processes that occur in the electric drive of electromechanical device. Characteristics of the main modes of motion were recorded. The introduction of electromechanical device will reduce the level of emissions and reduce noise in the cities

  9. Accessory atrioventricular myocardial connections in the developing human heart: relevance for perinatal supraventricular tachycardias

    NARCIS (Netherlands)

    Hahurij, Nathan D.; Gittenberger-de Groot, Adriana C.; Kolditz, Denise P.; Bökenkamp, Regina; Schalij, Martin J.; Poelmann, Robert E.; Blom, Nico A.

    2008-01-01

    BACKGROUND: Fetal and neonatal atrioventricular (AV) reentrant tachycardias can be life-threatening but resolve in most cases during the first year of life. The transient presence of accessory AV myocardial connections during annulus fibrosus development may explain this phenomenon. METHODS AND

  10. Understanding adolescent development: implications for driving safety.

    Science.gov (United States)

    Keating, Daniel P

    2007-01-01

    The implementation of Graduated Driver Licensing (GDL) programs has significantly improved the crash and fatality rates of novice teen drivers, but these rates remain unacceptably high. A review of adolescent development research was undertaken to identify potential areas of improvement. Research support for GDL was found to be strong, particularly regarding early acquisition of expertise in driving safety (beyond driving skill), and to limitations that reduce opportunities for distraction. GDL regimes are highly variable, and no US jurisdictions have implemented optimal regimes. Expanding and improving GDL to enhance acquisition of expertise and self-regulation are indicated for implementation and for applied research. Driver training that effectively incorporates safety goals along with driving skill is another target. The insurance industry will benefit from further GDL enhancements. Benefits may accrue to improved driver training, improved simulation devices during training, and automated safety feedback instrumentation.

  11. Dietary n-3 PUFA affect TcR-mediated activation of purified murine T cells and accessory cell function in co-cultures

    Science.gov (United States)

    CHAPKIN, R S; ARRINGTON, J L; APANASOVICH, T V; CARROLL, R J; MCMURRAY, D N

    2002-01-01

    Diets enriched in n-3 polyunsaturated fatty acids (PUFA) suppress several functions of murine splenic T cells by acting directly on the T cells and/or indirectly on accessory cells. In this study, the relative contribution of highly purified populations of the two cell types to the dietary suppression of T cell function was examined. Mice were fed diets containing different levels of n-3 PUFA; safflower oil (SAF; control containing no n-3 PUFA), fish oil (FO) at 2% and 4%, or 1% purified docosahexaenoic acid (DHA) for 2 weeks. Purified (>90%) T cells were obtained from the spleen, and accessory cells (>95% adherent, esterase-positive) were obtained by peritoneal lavage. Purified T cells or accessory cells from each diet group were co-cultured with the alternative cell type from every other diet group, yielding a total of 16 different co-culture combinations. The T cells were stimulated with either concanavalin A (ConA) or antibodies to the T cell receptor (TcR)/CD3 complex and the costimulatory molecule CD28 (αCD3/αCD28), and proliferation was measured after four days. Suppression of T cell proliferation in the co-cultures was dependent upon the dose of dietary n-3 PUFA fed to mice from which the T cells were derived, irrespective of the dietary treatment of accessory cell donors. The greatest dietary effect was seen in mice consuming the DHA diet (P = 0·034 in the anova; P = 0·0053 in the Trend Test), and was observed with direct stimulation of the T cell receptor and CD28 costimulatory ligand, but not with ConA. A significant dietary effect was also contributed accessory cells (P = 0·033 in the Trend Test). We conclude that dietary n-3 PUFA affect TcR-mediated by T cell activation by both direct and indirect (accessory cell) mechanisms. PMID:12296847

  12. Diagnostic device for failures in control rod drives

    International Nuclear Information System (INIS)

    Okutani, Tetsuro.

    1982-01-01

    Purpose: To enable to concretely point out a failure position when a failure might occur by diagnosing the failure without affecting the variation to the state of a reactor core. Constitution: A frequency switching circuit is provided in an inverter for controlling the rotating speed of a motor for discharging and charging a control rod. Then, a voltage detector is provided at asemiconductor switch provided between the inverter and the motor. When a high frequency control signal is input to the inverter in diagnosing a failure, the switching speed of the switch is accelerated, a current hardly flows through the motor, and even if the inverter is operated, the motor will not rotate. Thus, the failure of a control rod drive can be diagnosed without affecting any influence to the state of a reactor core. (Kamimura, M.)

  13. Development of magnetic drive packless valves for commercial purpose

    International Nuclear Information System (INIS)

    Hwang, Sung Tai; Choi, J. H.; Jeong, K. C.; Jeong, J. Y.; Choi, Y. D.; Kwon, S. W.; Kim, B. H.

    1997-01-01

    A study on development of magnetic drive packless valves for commercial purpose showed the results as follows: 1) characteristics and principle of the valve 2) study on the radial rays effecting to the permanent magnets 3) effects of temperature on the magnetic driving device a) temperature-dependency of the Nd-casting magnets b) effects of temperature on the heat releasing fins of high-temperature valve 4) optimization of torque a) arranging method of permanent magnets b) measuring method and results of torque 5) enlargement of magnetic rotating force a) experiments for the torque enlargement 6) calculation and pressure test for the pressure-resisting structure of magnetic power transmitting device a) calculation for the flat circular plates under pressure b) pressure test of the separating plate 7) design and manufacture of the valve 8) patent application. (author). 1 ref., 18 tabs., 38 figs

  14. Fast-wave current drive modelling for large non-circular tokamaks

    International Nuclear Information System (INIS)

    Batchelor, D.B.; Goldfinger, R.C.; Jaeger, E.F.; Carter, M.D.; Swain, D.W.; Ehst, D.; Karney, C.F.F.

    1990-01-01

    It is widely recognized that a key element in the development of an attractive tokamak reactor, and in the successful achievement of the mission of ITER, is the development of an efficient steady-state current drive technique. Fast waves in the ion cyclotron range of frequencies hold the promise to drive steady-state currents with the required efficiency and to effectively heat the plasma to ignition. Advantages over other heating and current drive techniques include low cost per watt and the ability to penetrate to the center of high-density plasmas. The primary issues that must be resolved are: can an antenna array be designed to radiate the required spectrum of waves and have adequate coupling properties? Will the rf power be efficiently absorbed by electrons in the desired velocity range without unacceptable parasitic damping by fuel ions or α particles? What will the efficiency of current drive be when toroidal effects such as trapped particles are included? Can a practical rf system be designed and integrated into the device? We have addressed these issues by performing extensive calculations with ORION, a 2-D code, and the ray tracing code RAYS, which calculate wave propagation, absorption and current drive in tokamak geometry, and with RIP, a 2-D code that self-consistently calculates current drive with MHD equilibrium. An important figure of merit in this context is the integrated, normalized current drive efficiency. The calculations that we present here emphasize the ITER device. We consider a low-frequency scenario such that no ion resonances appear in the machine, and a high-frequency scenario such that the deuterium second harmonic resonance is just outside the plasma and the tritium second harmonic is in the plasma, midway between the magnetic axis and the inside edge. In both cases electron currents are driven by combined TTMP and Landau damping of the fast waves

  15. Isoform-specific functions of Mud/NuMA mediate binucleation of Drosophila male accessory gland cells.

    Science.gov (United States)

    Taniguchi, Kiichiro; Kokuryo, Akihiko; Imano, Takao; Minami, Ryunosuke; Nakagoshi, Hideki; Adachi-Yamada, Takashi

    2014-12-20

    In standard cell division, the cells undergo karyokinesis and then cytokinesis. Some cells, however, such as cardiomyocytes and hepatocytes, can produce binucleate cells by going through mitosis without cytokinesis. This cytokinesis skipping is thought to be due to the inhibition of cytokinesis machinery such as the central spindle or the contractile ring, but the mechanisms regulating it are unclear. We investigated them by characterizing the binucleation event during development of the Drosophila male accessory gland, in which all cells are binucleate. The accessory gland cells arrested the cell cycle at 50 hours after puparium formation (APF) and in the middle of the pupal stage stopped proliferating for 5 hours. They then restarted the cell cycle and at 55 hours APF entered the M-phase synchronously. At this stage, accessory gland cells binucleated by mitosis without cytokinesis. Binucleating cells displayed the standard karyokinesis progression but also showed unusual features such as a non-round shape, spindle orientation along the apico-basal axis, and poor assembly of the central spindle. Mud, a Drosophila homolog of NuMA, regulated the processes responsible for these three features, the classical isoform Mud(PBD) and the two newly characterized isoforms Mud(L) and Mud(S) regulated them differently: Mud(L) repressed cell rounding, Mud(PBD) and Mud(S) oriented the spindle along the apico-basal axis, and Mud(S) and Mud(L) repressed central spindle assembly. Importantly, overexpression of Mud(S) induced binucleation even in standard proliferating cells such as those in imaginal discs. We characterized the binucleation in the Drosophila male accessory gland and examined mechanisms that regulated unusual morphologies of binucleating cells. We demonstrated that Mud, a microtubule binding protein regulating spindle orientation, was involved in this binucleation. We suggest that atypical functions exerted by three structurally different isoforms of Mud regulate

  16. Oxygen isotopes in garnet and accessory minerals to constrain fluids in subducted crust

    Science.gov (United States)

    Rubatto, Daniela; Gauthiez-Putallaz, Laure; Regis, Daniele; Rosa Scicchitano, Maria; Vho, Alice; Williams, Morgan

    2017-04-01

    Fluids are considered a fundamental agent for chemical exchanges between different rock types in the subduction system. Constraints on the sources and pathways of subduction fluids thus provide crucial information to reconstruct subduction processes. Garnet and U-Pb accessory minerals constitute some of the most robust and ubiquitous minerals in subducted crust and can preserve multiple growth zones that track the metamorphic evolution of the sample they are hosted in. Microbeam investigation of the chemical (major and trace elements) and isotopic composition (oxygen and U-Pb) of garnet and accessory minerals is used to track significant fluid-rock interaction at different stages of the subduction system. This approach requires consideration of the diffusivity of oxygen isotopes particularly in garnet, which has been investigated experimentally. The nature of the protolith and ocean floor alteration is preserved in relict accessory phases within eclogites that have been fully modified at HP conditions (e.g. Monviso and Dora Maira units in the Western Alps). Minerals in the lawsonite-blueschists of the Tavsanli zone in Turkey record pervasive fluid exchange between mafic and sedimentary blocks at the early stage of subduction. High pressure shear zones and lithological boundaries show evidence of intense fluid metasomatism at depth along discontinuities in Monviso and Corsica. In the UHP oceanic crust of the Zermatt-Saas Zone, garnet oxygen isotopes and tourmaline boron isotopes indicate multistage fluid infiltration during prograde metamorphism. Localized exchanges of aqueous fluids are also observed in the subducted continental crust of the Sesia-Lanzo Zone. In most cases analyses of distinct mineral zones enable identification of multiple pulses of fluids during the rock evolution.

  17. Next Generation Environmentally-Friendly Driving Feedback Systems Research and Development

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Matthew [Regents Of The University Of California, Riverside, CA (United States); Boriboonsomsin, Kanok [Regents Of The University Of California, Riverside, CA (United States)

    2014-12-31

    The objective of this project is to design, develop, and demonstrate a next-generation, federal safety- and emission-complaint driving feedback system that can be deployed across the existing vehicle fleet and improve fleet average fuel efficiency by at least 2%. The project objective was achieved with the driving feedback system that encourages fuel-efficient vehicle travel and operation through: 1) Eco-Routing Navigation module that suggests the most fuel-efficient route from one stop to the next, 2) Eco-Driving Feedback module that provides sensible information, recommendation, and warning regarding fuel-efficient vehicle operation, and 3) Eco-Score and Eco-Rank module that provides a means for driving performance tracking, self-evaluation, and peer comparison. The system also collects and stores vehicle travel and operation data, which are used by Algorithm Updating module to customize the other modules for specific vehicles and adapts them to specific drivers over time. The driving feedback system was designed and developed as an aftermarket technology that can be retrofitted to vehicles in the existing fleet. It consists of a mobile application for smart devices running Android operating system, a vehicle on-board diagnostics connector, and a data server. While the system receives and utilizes real-time vehicle and engine data from the vehicle’s controller area network bus through the vehicle’s on-board diagnostic connector, it does not modify or interfere with the vehicle’s controller area network bus, and thus, is in compliance with federal safety and emission regulations. The driving feedback system was demonstrated and then installed on 45 vehicles from three different fleets for field operational test. These include 15 private vehicles of the general public, 15 pickup trucks of the California Department of Transportation that are assigned to individual employees for business use, and 15 shuttle buses of the Riverside Transit Agency that are used

  18. Synergistic action of recombinant accessory hemicellulolytic and pectinolytic enzymes to Trichoderma reesei cellulase on rice straw degradation.

    Science.gov (United States)

    Laothanachareon, Thanaporn; Bunterngsook, Benjarat; Suwannarangsee, Surisa; Eurwilaichitr, Lily; Champreda, Verawat

    2015-12-01

    Synergism between core cellulases and accessory hydrolytic/non-hydrolytic enzymes is the basis of efficient hydrolysis of lignocelluloses. In this study, the synergistic action of three recombinant accessory enzymes, namely GH62 α-l-arabinofuranosidase (ARA), CE8 pectin esterase (PET), and GH10 endo-1,4-beta-xylanase (XYL) from Aspergillus aculeatus expressed in Pichia pastoris to a commercial Trichoderma reesei cellulase (Accellerase® 1500; ACR) on hydrolysis of alkaline pretreated rice straw was studied using a mixture design approach. Applying the full cubic model, the optimal ratio of quaternary enzyme mixture was predicted to be ACR:ARA:PET:XYL of 0.171:0.079:0.100:0.150, which showed a glucose releasing efficiency of 0.173 gglc/FPU, higher than the binary ACR:XYL mixture (0.122 gglc/FPU) and ACR alone (0.081 gglc/FPU) leading to a 47.3% increase in glucose yield compared with that from ACR at the same cellulase dosage. The result demonstrates the varying degree of synergism of accessory enzymes to cellulases useful for developing tailor-made enzyme systems for bio-industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Towards Flexibility Detection in Device-Level Energy Consumption

    DEFF Research Database (Denmark)

    Neupane, Bijay; Pedersen, Torben Bach; Thiesson, Bo

    2014-01-01

    The increasing drive towards green energy has boosted the installation of Renewable Energy Sources (RES). Increasing the share of RES in the power grid requires demand management by flexibility in the consumption. In this paper, we perform a state-of-the-art analysis on the flexibility and operat......The increasing drive towards green energy has boosted the installation of Renewable Energy Sources (RES). Increasing the share of RES in the power grid requires demand management by flexibility in the consumption. In this paper, we perform a state-of-the-art analysis on the flexibility...... and operation patterns of the devices in a set of real households. We propose a number of specific pre-processing steps such as operation stage segmentation, and aberrant operation duration removal to clean device level data. Further, we demonstrate various device operation properties such as hourly and daily...... regularities and patterns and the correlation between operating different devices. Subsequently, we show the existence of detectable time and energy flexibility in device operations. Finally, we provide various results providing a foundation for load- and flexibility-detection and -prediction at the device...

  20. Control rod drives

    International Nuclear Information System (INIS)

    Furumitsu, Yutaka.

    1981-01-01

    Purpose: To improve the reliability of a device for driving an LMFBR type reactor control rod by providing a buffer unit having a stationary electromagnetic coil and a movable electromagnetic coil in the device to thereby avord impact stress at scram time and to simplify the structure of the buffer unit. Constitution: A non-contact type buffer unit is constructed with a stationary electromagnetic coil, a cable for the stationary coil, a movable electromagnetic coil, a spring cable for the movable coil, and a backup coil spring or the like. Force produced at scram time is delivered without impact by the attracting or repelling force between the stationary coil and the movable coil of the buffer unit. Accordingly, since the buffer unit is of a non-contact type, there is no mechanical impact and thus no large impact stress, and as it has simple configuration, the reliability is improved and the maintenance can be conducted more easily. (Yoshihara, H.)

  1. Terminal phalangeal accessory ossification center of the thumb: an additional radiographic finding in Larsen syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Alanay, Yasemin [Hacettepe University, Clinical Genetics Unit, Department of Pediatrics, Faculty of Medicine, Ankara (Turkey); Cedars-Sinai Medical Center, Medical Genetics Institute, Los Angeles, CA (United States); Utine, Gulen E.; Tuncbilek, Ergul [Hacettepe University, Clinical Genetics Unit, Department of Pediatrics, Faculty of Medicine, Ankara (Turkey); Lachman, Ralph S. [Cedars-Sinai Medical Center, Medical Genetics Institute, Los Angeles, CA (United States); David Geffen School of Medicine at UCLA, Department of Radiological Sciences, Los Angeles, CA (United States); David Geffen School of Medicine at UCLA, Department of Pediatrics, Los Angeles, CA (United States); Krakow, Deborah [Cedars-Sinai Medical Center, Medical Genetics Institute, Los Angeles, CA (United States); David Geffen School of Medicine at UCLA, Department of Obstetrics and Gynecology, Los Angeles, CA (United States)

    2006-09-15

    Larsen syndrome is an autosomal-dominant disorder characterized by multiple joint dislocations, vertebral anomalies and dysmorphic facies. Both autosomal-dominant and autosomal-recessive forms of the disorder have been proposed. Individuals with autosomal-dominant Larsen syndrome have characteristic ''cylindrical-shape'' thumbs caused by broad, shortened phalanges. Autosomal-dominant Larsen syndrome results from heterozygosity for mutations in filamin B, a cytoskeletal protein involved in multicellular processes. We report here a patient with a duplicated or accessory distal thumb phalanx and multiple large joint dislocations who was shown to be heterozygous for a filamin B mutation predicting the amino acid substitution G1691S. This adds a new radiographic finding, duplicated or accessory distal phalanx, to the radiographic abnormalities seen in this rare dominant disorder. (orig.)

  2. Performance improvement of sensorless vector control for matrix converter drives using PQR power theory

    DEFF Research Database (Denmark)

    Lee, Kyo Beum; Blaabjerg, Frede

    2007-01-01

    This paper presents a new method to improve sensorless performance of matrix converter drives using PQR power transformation. The non-linearity of matrix converter drives such as commutation delay, turn-on and turn-off time of switching device, and on-state switching device voltage drop is modelled...... using PQR transformation and compensated using a reference current control scheme. To eliminate the input current distortion due to the input voltage unbalance, a simple method using PQR transformation is also proposed. The proposed compensation method is applied for high performance induction motor...

  3. Control rod control device

    International Nuclear Information System (INIS)

    Seiji, Takehiko; Obara, Kohei; Yanagihashi, Kazumi

    1998-01-01

    The present invention provides a device suitable for switching of electric motors for driving each of control rods in a nuclear reactor. Namely, in a control rod controlling device, a plurality of previously allotted electric motors connected in parallel as groups, and electric motors of any selected group are driven. In this case, a voltage of not driving predetermined selected electric motors is at first applied. In this state an electric current supplied to the circuit of predetermined electric motors is detected. Whether integration or failure of a power source and the circuit of the predetermined electric motors are normal or not is judged by the detected electric current supplied. After they are judged normal, the electric motors are driven by a regular voltage. With such procedures, whether the selected circuit is normal or not can be accurately confirmed previously. Since the electric motors are not driven just at the selected time, the control rods are not operated erroneously. (I.S.)

  4. Improving the supply chain agility of a fashion accessories company

    OpenAIRE

    Rosenlund, Kristian

    2015-01-01

    This thesis aims to improve the supply chain agility of a case company that is engaged in the design, development and worldwide marketing and selling of fashion accessories and design services. This thesis explores agility in context of supply chain management and in fashion industry where the typical challenges are that demand is highly volatile and hard to predict, the number of products per sales season is large and products have a fairly short life-cycles. In this study, the research ...

  5. Fast-acting nuclear reactor control device

    International Nuclear Information System (INIS)

    Kotlyar, O.M.; West, P.B.

    1993-01-01

    A fast-acting nuclear reactor control device is described for controlling a safety control rod within the core of a nuclear reactor, the reactor controlled by a reactor control system, the device comprising: a safety control rod drive shaft and an electromagnetic clutch co-axial with the drive shaft operatively connected to the safety control rod for driving and positioning the safety control rod within or without the reactor core during reactor operation, the safety rod being oriented in a substantially vertical position to allow the rod to fall into the reactor core under the influence of gravity during shutdown of the reactor; the safety control rod drive shaft further operatively connected to a hydraulic pump such that operation of the drive shaft simultaneously drives and positions the safety control rod and operates the hydraulic pump such that a hydraulic fluid is forced into an accumulator, filling the accumulator with oil for the storage and supply of primary potential energy for safety control rod insertion such that the release of potential energy in the accumulator causes hydraulic fluid to flow through the hydraulic pump, converting the hydraulic pump to a hydraulic motor having speed and power capable of full length insertion and high speed driving of the safety control rod into the reactor core; a solenoid valve interposed between the hydraulic pump and the accumulator, said solenoid valve being a normally open valve, actuated to close when the safety control rod is out of the reactor during reactor operation; and further wherein said solenoid opens in response to a signal from the reactor control system calling for shutdown of the reactor and rapid insertion of the safety control rod into the reactor core, such that the opening of the solenoid releases the potential energy in the accumulator to place the safety control rod in a safe shutdown position

  6. Behaviour of bentonite accessory minerals during the thermal stage

    International Nuclear Information System (INIS)

    Arcos, David; Bruno, Jordi; Benbow, Steven; Takase, Hiro

    2000-03-01

    This report discusses in a quantitative manner the evolution of the accessory minerals in the bentonite as a result of the thermal event exerted by the spent fuel in the near field. Three different modelling approaches have been used and the results compared between them. The three different approaches have been calculated using two Differential Algebraic Equation (DAE) solver: DYLAN (Model-1) and the Nag DAE solver, d02ngf (Model-2) and the third approach (Model-3) using the last version of PHREEQC. The results from these calculations indicate the feasibility of the modelling approach to model the migration of bentonite accessory minerals and relevant aqueous species throughout the thermal gradient. These calculations indicate that the migration of quartz and quartz polymorphs is a lesser problem. The aqueous speciation of Ca in the bentonite pore water is fundamental in order to define the potential migration of anhydrite during the thermal stage. If CaSO 4 (aq) is the predominant aqueous species, then anhydrite dissolves at the initial groundwater migration times through bentonite. However, if Ca 2+ is considered to be the dominant Ca species at the bentonite pore water, then anhydrite migrates towards the clay/granite interface. This is the main difference in the chemical systems considered in the three model approaches used in this work. The main process affecting the trace mineral behaviour in bentonite is cation exchange. This process controls the concentration of calcium, which results in a direct control of the calcite precipitation-dissolution

  7. Charging device for an electrostatic accelerator

    International Nuclear Information System (INIS)

    Pivovar, L.I.; Khurgin, K.M.

    1983-01-01

    The invention relates to electrostatic accelerators operating in compressed gases and charged by a charge-carrying belt transport device with driving and driven shafts. The aim of the invention is the increase of service life of the device by decreasing deflection of the charge-carrying belt in high-voltage conductor operation at high voltages. Increase of survice life of the device is provided due to the fact that the belt as a whole is more stable and it runs true without slacking shielding rods

  8. Speed-Sensorless DTC-SVM for Matrix Converter Drives With Simple Non-Linearity Compensation

    DEFF Research Database (Denmark)

    Lee, Kyo-Beum; Blaabjerg, Frede; Yoon, Tae-Woong

    2005-01-01

    This paper presents a new method to improve sensorless performance of matrix converter drives using a parameter estimation scheme. To improve low-speed sensorless performance, the non-Iinearities of a matrix converter drive such as commutation delays, turn-on and turn-off times of switching devic...... method is applied for high performance induction motor drives using a 3 kW matrix converter system without a speed sensor. Experimental results are shown to illustrate the feasibility of the proposed strategy....

  9. Study of lower hybrid current drive system in tokamak fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Maebara, Sunao [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-01-01

    This report describes R and D of a high-power klystron, RF vacuum window, low-outgassing antenna and a front module for a plasma-facing antenna aiming the 5 GHz Lower Hybrid Current Drive (LHCD) system for the next Tokamak Fusion Device. 5 GHz klystron with a low-perveances of 0.7 {mu}P is designed for a high-power and a high-efficiency, the output-power of 715 kW and the efficiency of 63%, which are beyond the conventional design scaling of 450 kW-45%, are performed using the prototype klystron which operates at the pulse duration of 15 {mu}sec. A new pillbox window, which has an oversized length in both the axial and the radial direction, are designed to reduce the RF power density and the electric field strength at the ceramics. It is evaluated that the power capability by cooling edge of ceramics is 1 MW with continuous-wave operation. The antenna module using Dispersion Strengthened Copper which combines high mechanical property up to 500degC with high thermal conductivity, are developed for a low-outgassing antenna in a steady state operation. It is found that the outgassing rate is in the lower range of 4x10{sup -6} Pam{sup 3}/sm{sup 2} at the module temperature of 300degC, which requires no active vacuum pumping of the LHCD antenna. A front module using Carbon Fiber Composite (CFC) are fabricated and tested for a plasma facing antenna which has a high heat-resistive. Stationary operation of the CFC module with water cooling is performed at the RF power of 46 MWm{sup -2} (about 2 times higher than the design value) during 1000 sec, it is found that the outgassing rate is less than 10{sup -5} Pam{sup 3}/sm{sup 2} which is low enough for an antenna material. (author)

  10. Tetralogy of Fallot with restrictive ventricular septal defect by accessory tricuspid leaflet tissue

    OpenAIRE

    Mahipat Raj Soni; Deepak A. Bohara; Ajay U. Mahajan; Pratap J. Nathani

    2012-01-01

    In tetralogy of Fallot septal defect is usually large because of malalignment of outlet septum, restrictive defect has been reported rarely. We present a case of tetralogy of Fallot with accessory tricuspid leaflet tissue restricting ventricular septal defect. The report includes echocardiographic and catheter images of this rare presentation of tetralogy of Fallot.

  11. Microfluidics and Lab-on-a-Chip Devices

    DEFF Research Database (Denmark)

    Castillo, Jaime

    2015-01-01

    The rapid advances in microfabrication and nanofabrication in combination with the synthesis and discovery of new materials have propelled the drive to develop new technological devices such as smartphones, personal and tablet computers. These devices have changed the way humankind interacts......TAS technologies need to join forces with those behind the new communication devices which provide sources of power, detection and data transmission complementing the features that lab-on-a-chip and microTAS platforms can offer. An increasing number of microfluidic-based devices, developed both in small start...

  12. A neonate with mitral stenosis due to accessory mitral valve, ventricular septal defect, and patent ductus arteriosus: changes in echocardiographical findings during the neonatal period.

    Science.gov (United States)

    Ito, Tadahiko; Okubo, Tadashi

    2002-12-01

    A female neonate with mitral stenosis due to accessory mitral valve with ventricular septal defect and patent ductus arteriosus is described. She was referred to our hospital because of neonatal asphyxia. Asphyxia was improved by ventilator support, but rapid deterioration of respiration with pulmonary congestion and hemorrhage appeared 8 days after birth. Echocardiography revealed an accessory mitral valve attached to the anterior mitral leaflet with a perimembranous ventricular septal defect and patent ductus arteriosus. Although there were no echocardiographical findings indicating mitral stenosis on admission, the mitral stenosis blood flow patterns were detected by color and pulsed Doppler examination performed on the eighth day after admission. Transaortic resection of accessory mitral valve tissue was performed with patch closure of the ventricular septal defect and ligation of the ductus arteriosus 35 days after birth. After operation, pulmonary congestion and hemorrhage were improved. Postoperative echocardiography showed complete resection of the accessory mitral valve and no mitral insufficiency. We concluded that the combination of the accessory mitral valve and left-to-right shunt due to ventricular septal defect or patent ducturs arteriosus might have led to a critical hemodynamic condition due to relative mitral stenosis in the neonatal period with the decrease in pulmonary vascular resistance.

  13. Localization of accessory pathway in patients with wolff-parkinson-white syndrome from surface ecg using arruda algorithm

    International Nuclear Information System (INIS)

    Saidullah, S.; Shah, B.

    2016-01-01

    Background: To ablate accessory pathway successfully and conveniently, accurate localization of the pathway is needed. Electrophysiologists use different algorithms before taking the patients to the electrophysiology (EP) laboratory to plan the intervention accordingly. In this study, we used Arruda algorithm to locate the accessory pathway. The objective of the study was to determine the accuracy of the Arruda algorithm for locating the pathway on surface ECG. Methods: It was a cross-sectional observational study conducted from January 2014 to January 2016 in the electrophysiology department of Hayat Abad Medical Complex Peshawar Pakistan. A total of fifty nine (n=59) consecutive patients of both genders between age 14-60 years presented with WPW syndrome (Symptomatic tachycardia with delta wave on surface ECG) were included in the study. Patient's electrocardiogram (ECG) before taking patients to laboratory was analysed on Arruda algorithm. Standard four wires protocol was used for EP study before ablation. Once the findings were confirmed the pathway was ablated as per standard guidelines. Results: A total of fifty nine (n=59) patients between the age 14-60 years were included in the study. Cumulative mean age was 31.5 years ± 12.5 SD. There were 56.4% (n=31) males with mean age 28.2 years ± 10.2 SD and 43.6% (n=24) were females with mean age 35.9 years ± 14.0 SD. Arruda algorithm was found to be accurate in predicting the exact accessory pathway (AP) in 83.6% (n=46) cases. Among all inaccurate predictions (n=9), Arruda inaccurately predicted two third (n=6; 66.7%) pathways towards right side (right posteroseptal, right posterolateral and right antrolateral). Conclusion: Arruda algorithm was found highly accurate in predicting accessory pathway before ablation. (author)

  14. Brief communication: Population variation in human maxillary premolar accessory ridges (MxPAR).

    Science.gov (United States)

    Burnett, Scott E; Hawkey, Diane E; Turner, Christy G

    2010-02-01

    The purpose of this brief communication is to report the results of an analysis of maxillary premolar accessory ridges (MxPAR), a common but understudied accessory ridge that may occur both mesial and distal to the central ridge of the buccal cusp of upper premolars. We developed a new five-grade scoring plaque to better categorize MxPAR variation. Subsequently, we conducted a population analysis of MxPAR frequency in 749 dental casts of South African Indian, American Chinese, Alaskan Eskimo, Tohono O'odham (Papago), Akimel O'odham (Pima), Solomon Islander, South African Bantu, and both American and South African Whites. Northeast Asian and Asian-derived populations exhibited the highest MxPAR frequencies while Indo-European samples (South African Indians, American and South African Whites) exhibited relatively low frequencies. The Solomon Islanders and South African Bantu samples exhibited intermediate frequencies. Our analysis indicates that statistically significant differences in MxPAR frequency exist between major geographic populations. As a result, the MxPAR plaque has now been added to the Arizona State University Dental Anthropology System, an important contribution as maxillary premolar traits are underrepresented in analyses of dental morphology. 2009 Wiley-Liss, Inc.

  15. Phrenic nerve neurotization utilizing the spinal accessory nerve: technical note with potential application in patients with high cervical quadriplegia.

    Science.gov (United States)

    Tubbs, R Shane; Pearson, Blake; Loukas, Marios; Shokouhi, Ghaffar; Shoja, Mohammadali M; Oakes, W Jerry

    2008-11-01

    High cervical quadriplegia is associated with high morbidity and mortality. Artificial respiration in these patients carries significant long-term risks such as infection, atelectasis, and respiratory failure. As phrenic nerve pacing has been proven to free many of these patients from ventilatory dependency, we hypothesized that neurotization of the phrenic nerve with the spinal accessory nerve (SAN) may offer one potential alternative to phrenic nerve stimulation via pacing and may be more efficacious and longer lasting without the complications of an implantable device. Ten cadavers (20 sides) underwent exposure of the cervical phrenic nerve and the SAN in the posterior cervical triangle. The SAN was split into anterior and posterior halves and the anterior half transposed to the ipsilateral phrenic nerve as it crossed the anterior scalene muscle. The mean distance between the cervical phrenic nerve and the SAN in the posterior cervical triangle was 2.5 cm proximally, 4 cm at a midpoint, and 6 cm distally. The range for these measurements was 2 to 4 cm, 3.5 to 5 cm, and 4 to 8.5 cm, respectively. The mean excess length of SAN available after transposition to the more anteromedially placed phrenic nerve was 5 cm (range 4 to 6.5 cm). The mean diameter of these regional parts of the spinal accessory and phrenic nerves was 2 and 2.5 mm, respectively. No statistically significant difference was found for measurements between sides. To our knowledge, using the SAN for neurotization to the phrenic nerve for potential use in patients with spinal cord injury has not been previously explored. Following clinical trials, these data may provide a mechanism for self stimulation of the diaphragm and obviate phrenic nerve pacing in patients with high cervical quadriplegia. Our study found that such a maneuver is technically feasible in the cadaver.

  16. {100} or 45.degree.-rotated {100}, semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2012-05-15

    Novel articles and methods to fabricate the same resulting in flexible, {100} or 45.degree.-rotated {100} oriented, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  17. Driving Control for Electric Power Assisted Wheelchair Based on Regenerative Brake

    Science.gov (United States)

    Seki, Hirokazu; Takahashi, Kazuki; Tadakuma, Susumu

    This paper describes a novel safety driving control scheme for electric power assisted wheelchairs based on the regenerative braking system. “Electric power assisted wheelchair” which assists the driving force by electric motors is expected to be widely used as a mobility support system for elderly people and disabled people, however, the safe and secure driving performance especially on downhill roads must be further improved because electric power assisted wheelchairs have no braking devices. The proposed control system automatically switches the driving mode, from “assisting mode” to “braking mode”, based on the wheelchair's velocity and the declined angle and smoothly suppresses the wheelchair's acceleration based on variable duty ratio control in order to realize the safety driving and to improve the ride quality. Some experiments on the practical roads and subjective evaluation show the effectiveness of the proposed control system.

  18. Chapter 18: Variable Frequency Drive Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Romberger, Jeff [SBW Consulting, Inc., Bellevue, WA (United States)

    2017-06-21

    An adjustable-speed drive (ASD) includes all devices that vary the speed of a rotating load, including those that vary the motor speed and linkage devices that allow constant motor speed while varying the load speed. The Variable Frequency Drive Evaluation Protocol presented here addresses evaluation issues for variable-frequency drives (VFDs) installed on commercial and industrial motor-driven centrifugal fans and pumps for which torque varies with speed. Constant torque load applications, such as those for positive displacement pumps, are not covered by this protocol.

  19. Intra-cardiac echocardiography guided catheter ablation of a right posterior accessory pathway in a patient with Ebstein׳s anomaly

    Directory of Open Access Journals (Sweden)

    Akira Shimane, MD

    2014-12-01

    Full Text Available We report a case of Ebstein׳s anomaly in which radiofrequency catheter ablation of an accessory pathway was successfully performed under intra-cardiac echocardiography. A 50-year-old woman was referred to our hospital for radiofrequency catheter ablation of a paroxysmal supraventricular tachycardia. A 12-lead surface electrocardiogram revealed ventricular pre-excitation associated with type B Wolff–Parkinson–White syndrome. In the baseline electrophysiological study, an orthodromic atrioventricular reciprocating tachycardia with a right posterior accessory pathway was induced. A phased-array intra-cardiac echo probe was positioned in the right atrium to visualize the atrioventricular junction. The key structures for catheter ablation, such as the atrialized right ventricle, atrioventricular junction, and tricuspid valve, were clearly visualized on intra-cardiac echocardiography. Radiofrequency current was successfully delivered at the atrioventricular junction, where a Kent potential was recorded. During a 6-month follow-up period, the patient was free from arrhythmias. The findings in this case suggest that phased-array intra-cardiac echocardiography is useful for ablation of right-sided accessory pathways in patients with Ebstein׳s anomaly.

  20. Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

    Science.gov (United States)

    Jacobson, Stephen C [Knoxville, TN; Ramsey, J Michael [Knoxville, TN

    2008-09-09

    A microfluidic device and method for forming and dispensing minute volume segments of a material are described. In accordance with the present invention, a microfluidic device and method are provided for spatially confining the material in a focusing element. The device is also adapted for segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

  1. Drive Control System for Pipeline Crawl Robot Based on CAN Bus

    International Nuclear Information System (INIS)

    Chen, H J; Gao, B T; Zhang, X H; Deng, Z Q

    2006-01-01

    Drive control system plays important roles in pipeline robot. In order to inspect the flaw and corrosion of seabed crude oil pipeline, an original mobile pipeline robot with crawler drive unit, power and monitor unit, central control unit, and ultrasonic wave inspection device is developed. The CAN bus connects these different function units and presents a reliable information channel. Considering the limited space, a compact hardware system is designed based on an ARM processor with two CAN controllers. With made-to-order CAN protocol for the crawl robot, an intelligent drive control system is developed. The implementation of the crawl robot demonstrates that the presented drive control scheme can meet the motion control requirements of the underwater pipeline crawl robot

  2. Drive Control System for Pipeline Crawl Robot Based on CAN Bus

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H J [Department of Electrical Engineering, Harbin Institute of Technology Harbin, Heilongjiang, 150001 (China); Gao, B T [Department of Electrical Engineering, Harbin Institute of Technology Harbin, Heilongjiang, 150001 (China); Zhang, X H [Department of Electrical Engineering, Harbin Institute of Technology Harbin, Heilongjiang, 150001 (China); Deng, Z Q [School of Mechanical Engineering, Harbin Institute of Technology Harbin, Heilongjiang, 150001 (China)

    2006-10-15

    Drive control system plays important roles in pipeline robot. In order to inspect the flaw and corrosion of seabed crude oil pipeline, an original mobile pipeline robot with crawler drive unit, power and monitor unit, central control unit, and ultrasonic wave inspection device is developed. The CAN bus connects these different function units and presents a reliable information channel. Considering the limited space, a compact hardware system is designed based on an ARM processor with two CAN controllers. With made-to-order CAN protocol for the crawl robot, an intelligent drive control system is developed. The implementation of the crawl robot demonstrates that the presented drive control scheme can meet the motion control requirements of the underwater pipeline crawl robot.

  3. Haptic device for telerobotic surgery

    Science.gov (United States)

    Salisbury, Curt; Salisbury, Jr., J. Kenneth

    2014-12-30

    A haptic device for telerobotic surgery, including a base; a linkage system having first and second linkage members coupled to the base; a motor that provides a motor force; a transmission including first and second driving pulleys arranged such that their faces form an angle and their axes form a plane, first and second idler pulleys offset from the plane and arranged between the first and second driving pulleys such that their axes divide the angle between the first and second driving pulleys, and a cable that traverses the first and second driving pulleys and the set of idler pulleys and transfers the motor force to the linkage system; an end effector coupled to distal ends of the first and second linkage members and maneuverable relative to the base; and a controller that modulates the motor force to simulate a body part at a point portion of the end effector.

  4. Congenital tri-cavernous hemangiomas of the right buccal region, right accessory parotid gland, and masseter muscle region.

    Science.gov (United States)

    Yang, Tao; Gu, Yongchun; Zhang, Li; Hua, Zequan

    2014-03-01

    We report a rare case of congenital tri-cavernous hemangiomas of the right buccal region, right accessory parotid gland, and masseter muscle region in an adult. The patient, a 25-year-old woman, complained of 3 masses in her right midcheek. Ultrasonographic and computed tomographic findings showed an irregular-shaped mass (multiple calcifications) with a well-defined margin in the masseter muscle region, an ellipse-shaped mass (multiple calcifications) with a well-defined margin in the right buccal region, and a comma-shaped mass (no calcifications) with a well-defined margin separate from the parotid gland in the right accessory parotid gland region. These iconographic findings suggested that the masses were all hemangiomas separately originating from the parotid gland, accessory parotid gland, and masseter muscle. The masses were completely removed through a standard parotid incision without postoperative facial palsy, skin deformity, and difficulty in secreting saliva. Findings from histologic examination of the tumor revealed multiple, thin-walled, and dilated blood vessels, confirming the diagnosis of cavernous hemangiomas. Ultrasonographic and computed tomographic findings were extremely useful in diagnosing the mass/masses as hemangioma before surgery, clarifying relationships between the mass and adjacent structures, and determining the surgical approach to the mass/masses.

  5. Flaw detection device

    International Nuclear Information System (INIS)

    Sasahara, Toshihiko

    1998-01-01

    The present invention provides a device for detecting welded portions of a reactor pressure vessel. Namely, the device of the present invention comprises (1) a casing to be disposed on the surface to be detected, (2) a probe driving means loaded to the casing, (3) a probe driven along the surface to be detected and (4) a pressure reduction means for keeping the hollow portion in the casing to an evacuated atmosphere. The casing comprises a flexible suction edge to be tightly in contact with the surface to be tested for maintaining the air tight state, (6) a guide wheel for moving the casing along the surface to be tested and (7) a handle for performing transferring operation. The flaw detection device thus constituted has following features. The working efficiency upon conducting detection is improved. The influence of the weight of the device on the detection is small. The device can be applied on the surface of a nonmagnetic material. The efficiency for the flaw detection can be improved. (I.S.)

  6. HIL Simulation of Power Electronics and Electric Drives for Automotive Applications

    OpenAIRE

    Frank Puschmann; Axel Kiffe; Thomas Schulte

    2012-01-01

    Hardware-in-the-loop simulation is today a standard method for testing electronic equipment in the automotive industry. Since electric drives and power electronic devices are more and more important in automotive applications, these kinds of systems have to be integrated into the hardware-in-the-loop simulation. Power converters and electric drives are used in many different applications in vehicles today (hybrid electric or electric powertrain, electric steering systems, DC-DC converters, et...

  7. A magnetorheological clutch for efficient automotive auxiliary device actuation

    Directory of Open Access Journals (Sweden)

    F. Bucchi

    2013-01-01

    Full Text Available In this paper the results of a project funded by Regione Toscana aimed at reducing the power absorption of auxiliary devices in vehicles are presented. In particular the design, testing and application of a magnetorheological clutch (MR is proposed, aimed at disengaging the vacuum pump, which draws in air from the power-brake booster chamber, in order to reduce the device power absorption. Several clutch preliminary studies done to choose the clutch geometry and the magnetic field supply are illustrated. The final choice consisted in an MR clutch with permanent magnet, which satisfied size, torque and fail-safe specifications. The clutch characteristics, in terms of torque versus slip, were obtained experimentally for three different clutch prototypes on an ad-hoc developed test bench.As result of a preliminary simulation, a comparison between the power absorption of a current production vacuum pump, an innovative vacuum pump and both vacuum pumps coupled with the MR clutch is presented. The New European Driving Cycle is considered for simulating the vacuum pump operation both in urban and highway driving. Results show that the use of the innovative vacuum pump reduces the device consumption of about 35%, whereas the use of MR clutch coupled with the innovative vacuum pump reduces it up to about 44% in urban driving and 50% in highway driving.

  8. Transcription Factors Encoded on Core and Accessory Chromosomes of Fusarium oxysporum Induce Expression of Effector Genes

    Science.gov (United States)

    van der Does, H. Charlotte; Schmidt, Sarah M.; Langereis, Léon; Hughes, Timothy R.

    2016-01-01

    Proteins secreted by pathogens during host colonization largely determine the outcome of pathogen-host interactions and are commonly called ‘effectors’. In fungal plant pathogens, coordinated transcriptional up-regulation of effector genes is a key feature of pathogenesis and effectors are often encoded in genomic regions with distinct repeat content, histone code and rate of evolution. In the tomato pathogen Fusarium oxysporum f. sp. lycopersici (Fol), effector genes reside on one of four accessory chromosomes, known as the ‘pathogenicity’ chromosome, which can be exchanged between strains through horizontal transfer. The three other accessory chromosomes in the Fol reference strain may also be important for virulence towards tomato. Expression of effector genes in Fol is highly up-regulated upon infection and requires Sge1, a transcription factor encoded on the core genome. Interestingly, the pathogenicity chromosome itself contains 13 predicted transcription factor genes and for all except one, there is a homolog on the core genome. We determined DNA binding specificity for nine transcription factors using oligonucleotide arrays. The binding sites for homologous transcription factors were highly similar, suggesting that extensive neofunctionalization of DNA binding specificity has not occurred. Several DNA binding sites are enriched on accessory chromosomes, and expression of FTF1, its core homolog FTF2 and SGE1 from a constitutive promoter can induce expression of effector genes. The DNA binding sites of only these three transcription factors are enriched among genes up-regulated during infection. We further show that Ftf1, Ftf2 and Sge1 can activate transcription from their binding sites in yeast. RNAseq analysis revealed that in strains with constitutive expression of FTF1, FTF2 or SGE1, expression of a similar set of plant-responsive genes on the pathogenicity chromosome is induced, including most effector genes. We conclude that the Fol

  9. Extended driving impairs nocturnal driving performances.

    Directory of Open Access Journals (Sweden)

    Patricia Sagaspe

    Full Text Available Though fatigue and sleepiness at the wheel are well-known risk factors for traffic accidents, many drivers combine extended driving and sleep deprivation. Fatigue-related accidents occur mainly at night but there is no experimental data available to determine if the duration of prior driving affects driving performance at night. Participants drove in 3 nocturnal driving sessions (3-5 am, 1-5 am and 9 pm-5 am on open highway. Fourteen young healthy men (mean age [+/-SD] = 23.4 [+/-1.7] years participated Inappropriate line crossings (ILC in the last hour of driving of each session, sleep variables, self-perceived fatigue and sleepiness were measured. Compared to the short (3-5 am driving session, the incidence rate ratio of inappropriate line crossings increased by 2.6 (95% CI, 1.1 to 6.0; P<.05 for the intermediate (1-5 am driving session and by 4.0 (CI, 1.7 to 9.4; P<.001 for the long (9 pm-5 am driving session. Compared to the reference session (9-10 pm, the incidence rate ratio of inappropriate line crossings were 6.0 (95% CI, 2.3 to 15.5; P<.001, 15.4 (CI, 4.6 to 51.5; P<.001 and 24.3 (CI, 7.4 to 79.5; P<.001, respectively, for the three different durations of driving. Self-rated fatigue and sleepiness scores were both positively correlated to driving impairment in the intermediate and long duration sessions (P<.05 and increased significantly during the nocturnal driving sessions compared to the reference session (P<.01. At night, extended driving impairs driving performances and therefore should be limited.

  10. Undressing "health fashion": an examination of health-cause clothing and accessories.

    Science.gov (United States)

    Walker, Kandi L; Hart, Joy L; Gregg, Jennifer L; LaJoie, A Scott

    2010-09-01

    Today, fashion items such as rubber wristbands in various colors, pink ribbons, and red dresses represent different health-related causes and can be seen frequently across demographic groups. Complete with pithy slogans (e.g., "Go Red for Women"), these items are part of a larger "health fashion" trend--one that involves wearing, using, and displaying health-cause clothing and accessories. In this article, the authors explore recent interest in "health fashion," examining in particular its origins, effectiveness, and implications.

  11. Enhanced thermal expansion control rod drive lines for improving passive safety of fast reactors

    International Nuclear Information System (INIS)

    Edelmann, M.; Baumann, W.; Kuechle, M.; Kussmaul, G.; Vaeth, W.; Bertram, A.

    1992-01-01

    The paper presents a device for increasing the thermal expansion effect of control rod drive lines on negative reactivity feedback in fast reactors. The enhanced thermal expansion of this device can be utilized for both passive rod drop and forced insertion of absorbers in unprotected transients, e.g. ULOF. In this way the reactor is automatically brought into a permanently subcritical state and temperatures are kept well below the boiling point of the coolant. A prototype of such a device called ATHENa (German: Shut-down by THermal Expansion of Na) is presently under construction and will be tested. The paper presents the principle, design features and thermal properties of ATHENs as well as results of reactor dynamics calculations of ULOF's for EFR with enhanced thermal expansion control rod drive lines. (author)

  12. Laparoscopic splenectomy for a simultaneous wandering spleen along with an ectopic accessory spleen. Case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Antonia Rizzuto

    Full Text Available Background: Wandering spleen and accessory spleen are uncommon entity occurring during embryonic development. Wandering spleen results in an excessive mobility and migration of the spleen from its normal position in the left hypochondrium while accessory spleen is characterized by ectopic splenic masses or tissue disjointed from the main body of spleen.Due to the nonspecific and multiple symptoms the clinical diagnosis of both conditions is uncertain even with imaging techniques, such as CT and MRI. The coexistence of both diseases (wandering spleen ad accessory spleen is uncommon. Case report: A 17–year old European female with a history of minor beta thalassemia and recurrent attacks of abdominal pain. Pre- operative management consisted of routine laboratory tests, ultrasound, CT scan. An ectopic spleen along with an accessory spleen were diagnosed. After a multidisciplinary board a laparoscopic splenectomy was performed. Post-operative recovery was uneventful, and the patient was discharged on the 6th post-operative day with the indication to continue the therapy with low molecular weight heparin (LMWH for 30 days Conclusions: This case represents a simultaneous condition of wandering splenomegaly along with an ectopic wandering spleen. The coexistence of these two rare conditions is peculiar such as the age of the patient, as literature reports such diseases to affect children or more commonly people in the range of 20–40 years of age. Laparoscopic treatment for this particular condition is also unusual. Keywords: Ectopic spleen, Wandering spleen, Laparoscopic splenectomy

  13. Simulations of the Fuel Economy and Emissions of Hybrid Transit Buses over Planned Local Routes

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Zhiming [ORNL; LaClair, Tim J [ORNL; Daw, C Stuart [ORNL; Smith, David E [ORNL; Franzese, Oscar [ORNL

    2014-01-01

    We present simulated fuel economy and emissions city transit buses powered by conventional diesel engines and diesel-hybrid electric powertrains of varying size. Six representative city drive cycles were included in the study. In addition, we included previously published aftertreatment device models for control of CO, HC, NOx, and particulate matter (PM) emissions. Our results reveal that bus hybridization can significantly enhance fuel economy by reducing engine idling time, reducing demands for accessory loads, exploiting regenerative braking, and shifting engine operation to speeds and loads with higher fuel efficiency. Increased hybridization also tends to monotonically reduce engine-out emissions, but trends in the tailpipe (post-aftertreatment) emissions involve more complex interactions that significantly depend on motor size and drive cycle details.

  14. Wongabel Rhabdovirus Accessory Protein U3 Targets the SWI/SNF Chromatin Remodeling Complex

    Science.gov (United States)

    Joubert, D. Albert; Rodriguez-Andres, Julio; Monaghan, Paul; Cummins, Michelle; McKinstry, William J.; Paradkar, Prasad N.; Moseley, Gregory W.

    2014-01-01

    ABSTRACT Wongabel virus (WONV) is an arthropod-borne rhabdovirus that infects birds. It is one of the growing array of rhabdoviruses with complex genomes that encode multiple accessory proteins of unknown function. In addition to the five canonical rhabdovirus structural protein genes (N, P, M, G, and L), the 13.2-kb negative-sense single-stranded RNA (ssRNA) WONV genome contains five uncharacterized accessory genes, one overlapping the N gene (Nx or U4), three located between the P and M genes (U1 to U3), and a fifth one overlapping the G gene (Gx or U5). Here we show that WONV U3 is expressed during infection in insect and mammalian cells and is required for efficient viral replication. A yeast two-hybrid screen against a mosquito cell cDNA library identified that WONV U3 interacts with the 83-amino-acid (aa) C-terminal domain of SNF5, a component of the SWI/SNF chromatin remodeling complex. The interaction was confirmed by affinity chromatography, and nuclear colocalization was established by confocal microscopy. Gene expression studies showed that SNF5 transcripts are upregulated during infection of mosquito cells with WONV, as well as West Nile virus (Flaviviridae) and bovine ephemeral fever virus (Rhabdoviridae), and that SNF5 knockdown results in increased WONV replication. WONV U3 also inhibits SNF5-regulated expression of the cytokine gene CSF1. The data suggest that WONV U3 targets the SWI/SNF complex to block the host response to infection. IMPORTANCE The rhabdoviruses comprise a large family of RNA viruses infecting plants, vertebrates, and invertebrates. In addition to the major structural proteins (N, P, M, G, and L), many rhabdoviruses encode a diverse array of accessory proteins of largely unknown function. Understanding the role of these proteins may reveal much about host-pathogen interactions in infected cells. Here we examine accessory protein U3 of Wongabel virus, an arthropod-borne rhabdovirus that infects birds. We show that U3 enters the

  15. Antegrade or Retrograde Accessory Pathway Conduction: Who Dies First?

    Directory of Open Access Journals (Sweden)

    Claudio Hadid, MD

    2012-05-01

    Full Text Available A 36 year-old man with Wolff Parkinson White syndrome due to a left-sided accessory pathway (AP was referred for catheter ablation. Whether abolition of antegrade and retrograde AP conduction during ablation therapy occurs simultaneously, is unclear. At the ablation procedure, radiofrequency delivery resulted in loss of preexcitation followed by a short run of orthodromic tachycardia with eccentric atrial activation, demonstrating persistence of retrograde conduction over the AP after abolition of its antegrade conduction. During continued radiofrequency delivery at the same position, the fifth non-preexcitated beat failed to conduct retrogradely and the tachycardia ended. In this case, antegrade AP conduction was abolished earlier than retrograde conduction.

  16. Frequency of Syncope in Patients with Accessory Atrioventricular Connection

    Directory of Open Access Journals (Sweden)

    A Aslani

    2010-03-01

    Full Text Available Background: Syncope in patients with Wolff-Parkinson-White (WPW syndrome is related to rapid reciprocating tachycardia or rapid ventricular response over the accessory pathway during atrial fibrillation (AF. The aim of this retrospective study is to evaluate the frequency of syncope in patients with WPW syndrome. Methods: We reviewed the records of 150 consecutive patients with WPW syndrome.Results: There were 20 patients (13.3% who reported at least one episode of syncope and 130 patients (86.7% without such a history.Conclusion: Syncope is relatively frequent in patients with WPW. Patient with WPW syndrome who has experienced this symptom should be thoroughly evaluated.

  17. Emergency reactor cooling device

    International Nuclear Information System (INIS)

    Arakawa, Ken.

    1993-01-01

    An emergency nuclear reactor cooling device comprises a water reservoir, emergency core cooling water pipelines having one end connected to a water feeding sparger, fire extinguishing facility pipelines, cooling water pressurizing pumps, a diesel driving machine for driving the pumps and a battery. In a water reservoir, cooling water is stored by an amount required for cooling the reactor upon emergency and for fire extinguishing, and fire extinguishing facility pipelines connecting the water reservoir and the fire extinguishing facility are in communication with the emergency core cooling water pipelines connected to the water feeding sparger by system connection pipelines. Pumps are operated by a diesel power generator to introduce cooling water from the reservoir to the emergency core cooling water pipelines. Then, even in a case where AC electric power source is entirely lost and the emergency core cooling system can not be used, the diesel driving machine is operated using an exclusive battery, thereby enabling to inject cooling water from the water reservoir to a reactor pressure vessel and a reactor container by the diesel drive pump. (N.H.)

  18. Identification and subcellular localization of porcine deltacoronavirus accessory protein NS6

    International Nuclear Information System (INIS)

    Fang, Puxian; Fang, Liurong; Liu, Xiaorong; Hong, Yingying; Wang, Yongle; Dong, Nan; Ma, Panpan; Bi, Jing; Wang, Dang; Xiao, Shaobo

    2016-01-01

    Porcine deltacoronavirus (PDCoV) is an emerging swine enteric coronavirus. Accessory proteins are genus-specific for coronavirus, and two putative accessory proteins, NS6 and NS7, are predicted to be encoded by PDCoV; however, this remains to be confirmed experimentally. Here, we identified the leader-body junction sites of NS6 subgenomic RNA (sgRNA) and found that the actual transcription regulatory sequence (TRS) utilized by NS6 is non-canonical and is located upstream of the predicted TRS. Using the purified NS6 from an Escherichia coli expression system, we obtained two anti-NS6 monoclonal antibodies that could detect the predicted NS6 in cells infected with PDCoV or transfected with NS6-expressing plasmids. Further studies revealed that NS6 is always localized in the cytoplasm of PDCoV-infected cells, mainly co-localizing with the endoplasmic reticulum (ER) and ER-Golgi intermediate compartments, as well as partially with the Golgi apparatus. Together, our results identify the NS6 sgRNA and demonstrate its expression in PDCoV-infected cells. -- Highlights: •The leader-body fusion site of NS6 sgRNA is identified. •NS6 sgRNA uses a non-canonical transcription regulatory sequence (TRS). •NS6 can be expressed in PDCoV-infected cell. •NS6 predominantly localize to the ER complex and ER-Golgi intermediate compartment.

  19. Identification and subcellular localization of porcine deltacoronavirus accessory protein NS6

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Puxian; Fang, Liurong; Liu, Xiaorong; Hong, Yingying; Wang, Yongle; Dong, Nan; Ma, Panpan [State Key Laboratory of Agricultural Microbiology, College of Veterinary Medicine, Huazhong Agricultural University, Wuhan 430070 (China); The Cooperative Innovation Center for Sustainable Pig Production, Wuhan 430070 (China); Bi, Jing [State Key Laboratory of Agricultural Microbiology, College of Veterinary Medicine, Huazhong Agricultural University, Wuhan 430070 (China); Department of Immunology and Aetology, College of Basic Medicine, Hubei University of Chinese Medicine, Wuhan 430065 (China); Wang, Dang [State Key Laboratory of Agricultural Microbiology, College of Veterinary Medicine, Huazhong Agricultural University, Wuhan 430070 (China); The Cooperative Innovation Center for Sustainable Pig Production, Wuhan 430070 (China); Xiao, Shaobo, E-mail: vet@mail.hzau.edu.cn [State Key Laboratory of Agricultural Microbiology, College of Veterinary Medicine, Huazhong Agricultural University, Wuhan 430070 (China); The Cooperative Innovation Center for Sustainable Pig Production, Wuhan 430070 (China)

    2016-12-15

    Porcine deltacoronavirus (PDCoV) is an emerging swine enteric coronavirus. Accessory proteins are genus-specific for coronavirus, and two putative accessory proteins, NS6 and NS7, are predicted to be encoded by PDCoV; however, this remains to be confirmed experimentally. Here, we identified the leader-body junction sites of NS6 subgenomic RNA (sgRNA) and found that the actual transcription regulatory sequence (TRS) utilized by NS6 is non-canonical and is located upstream of the predicted TRS. Using the purified NS6 from an Escherichia coli expression system, we obtained two anti-NS6 monoclonal antibodies that could detect the predicted NS6 in cells infected with PDCoV or transfected with NS6-expressing plasmids. Further studies revealed that NS6 is always localized in the cytoplasm of PDCoV-infected cells, mainly co-localizing with the endoplasmic reticulum (ER) and ER-Golgi intermediate compartments, as well as partially with the Golgi apparatus. Together, our results identify the NS6 sgRNA and demonstrate its expression in PDCoV-infected cells. -- Highlights: •The leader-body fusion site of NS6 sgRNA is identified. •NS6 sgRNA uses a non-canonical transcription regulatory sequence (TRS). •NS6 can be expressed in PDCoV-infected cell. •NS6 predominantly localize to the ER complex and ER-Golgi intermediate compartment.

  20. Radioactive rare gas recoverying device

    International Nuclear Information System (INIS)

    Kasai, Shigeo

    1989-01-01

    The apparatus of the present invention comprises a vessel for containing coolants, an introduction valve and an introduction pipe for introducing radioactive rare gases and an adsorption floor disposed in the coolants. A josephson device is disposed being immersed in the coolants between a radiation detector for detecting the radioactive level adsorbed to the adsorption floor and a driving section for driving the introduction valve by the signal from the detector. With this constitution, radioactive rare gases introduced into the coolants and then cooled and liquefied are recovered by the adsorption floor. As the adsorption proceeds and when the radioactivity level exceeds a maximum level in the effective shielding range of the recovery apparatus, the signal current from the radiation detector also exceeds a predetermined level. If radioactivity exceeds the maximum level, the electrical resistance of the josephson device is increased infinitely by the josephson effect to close the introduction valve. Accordingly, the radioactivity is not absorbed beyond the effective shielding range. (I.S.)

  1. Change in the collateral and accessory collateral ligament lengths of the proximal interphalangeal joint using cadaveric model three-dimensional laser scanning.

    Science.gov (United States)

    Sandhu, S S; Dreckmann, S; Binhammer, P A

    2016-05-01

    The purpose of this study was to assess the lengths of the index and middle finger proximal interphalangeal joint ligaments and determine the relative changes in the collateral and accessory collateral ligament lengths at 0°, 45° and 90° flexion. We generated three-dimensional scans of 16 finger (eight index and eight middle) proximal interphalangeal joints to assess relative changes in ligament length. Significant changes were found between 45°-90° and 0°-90° for the ulnar collateral ligament of the index finger and both collateral ligaments of the middle finger between 45°-90° and 0°-90°. No significant changes in length were found for the radial collateral ligament of the index finger or the accessory collateral ligaments of the index and middle fingers. Overall, it was found that the collateral ligament length changed significantly, but there was no significant change in the accessory collateral ligaments. Therapeutic IV. © The Author(s) 2015.

  2. Does Accessory Ossicle Affect Management Plan in an Athlete After Ankle Sprain? A Case Report

    Directory of Open Access Journals (Sweden)

    Şerife Şeyma TORĞUTALP

    2016-09-01

    Full Text Available Os subfibulare is an accessory ossicle that lies at the distal part of lateral malleolus. It is typically asymptomatic and detected incidentally by the presence of ankle injuries. A case report of sixteen years old male athlete with ankle injury was presented.

  3. Battery control system for hybrid vehicle and method for controlling a hybrid vehicle battery

    Science.gov (United States)

    Bockelmann, Thomas R [Battle Creek, MI; Hope, Mark E [Marshall, MI; Zou, Zhanjiang [Battle Creek, MI; Kang, Xiaosong [Battle Creek, MI

    2009-02-10

    A battery control system for hybrid vehicle includes a hybrid powertrain battery, a vehicle accessory battery, and a prime mover driven generator adapted to charge the vehicle accessory battery. A detecting arrangement is configured to monitor the vehicle accessory battery's state of charge. A controller is configured to activate the prime mover to drive the generator and recharge the vehicle accessory battery in response to the vehicle accessory battery's state of charge falling below a first predetermined level, or transfer electrical power from the hybrid powertrain battery to the vehicle accessory battery in response to the vehicle accessory battery's state of charge falling below a second predetermined level. The invention further includes a method for controlling a hybrid vehicle powertrain system.

  4. Stenosing Tenosynovitis of the Flexor Hallucis Longus Tendon Associated with the Plantar Capsular Accessory Ossicle at the Interphalangeal Joint of the Great Toe

    Directory of Open Access Journals (Sweden)

    Song Ho Chang

    2017-01-01

    Full Text Available This report presents a case of stenosing tenosynovitis of the flexor hallucis longus tendon associated with the plantar capsular accessory ossicle at the interphalangeal joint of the great toe, which was confirmed by intraoperative observation and was successfully treated with surgical resection of the ossicle. As the plantar capsular accessory ossicle was not visible radiographically due to the lack of ossification, ultrasonography was helpful for diagnosing this disorder.

  5. Evaluation of stray radiofrequency radiation emitted by electrosurgical devices

    International Nuclear Information System (INIS)

    De Marco, M; Maggi, S

    2006-01-01

    Electrosurgery refers to the passage of a high-frequency, high-voltage electrical current through the body to achieve the desired surgical effects. At the same time, these procedures are accompanied by a general increase of the electromagnetic field in an operating room that may expose both patients and personnel to relatively high levels of radiofrequency radiation. In the first part of this study, we have taken into account the radiation emitted by different monopolar electrosurgical devices, evaluating the electromagnetic field strength delivered by an electrosurgical handle and straying from units and other electrosurgical accessories. As a summary, in the worst case a surgeon's hands are exposed to a continuous and pulsed RF wave whose magnetic field strength is 0.75 A m -1 (E-field 400 V m -1 ). Occasionally stray radiation may exceed ICNIRP's occupational exposure guidelines, especially close to the patient return plate. In the second part of this paper, we have analysed areas of particular concern to prevent electromagnetic interference with some life-support devices (ventilators and electrocardiographic devices), which have failed to operate correctly. Most clinically relevant interference occurred when an electrosurgery device was used within 0.3 m of medical equipment. In the appendix, we suggest some practical recommendations intended to minimize the potential for electromagnetic hazards due to therapeutic application of RF energy

  6. Control system and method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the movable body part through the full-shrug position of the movable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the movable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective movable prosthesis device and its sub-prosthesis.

  7. Accessory mammary tissue associated with congenital and hereditary nephrourinary malformations.

    Science.gov (United States)

    Urbani, C E; Betti, R

    1996-05-01

    The association between polythelia (supernumerary nipple) and kidney and urinary tract malformations (KUTM) is controversial. Some authors reported this association in newborns and infants. Case-control studies dealing with adult subjects are not found in the literature. The purpose of this study is to determine the frequency of the association between accessory mammary tissue (AMT) and congenital and hereditary nephrourinary defects in an adult population compared to a control group. The study was performed in 146 white patients (123 men, 23 women) with AMT out of 2645 subjects consecutively referred to us for physical examination. The following investigations were undertaken: ultrasonographic examination of the abdomen and the kidneys, ECG, echocardiogram, roentgenogram of the vertebral column, urinalysis, and other laboratory tests. A sex- and age-matched control group without any evidence of AMT or lateral displacement of the nipples underwent the same examinations. Kidney and urinary tract malformations were detected in 11 patients with AMT (nine men, two women) and in one control. These data indicate a significantly higher frequency of KUTM in the AMT-affected patients compared to controls (7.53% vs. 0.68%, P < 0.001). A broad spectrum of KUTM was discovered in association with AMT: adult dominant polycystic kidney disease, unilateral renal agenesis, cystic renal dysplasia, familial renal cysts, and congenital stenosis of the pyeloureteral joint. Accessory mammary tissue offers an important clue for congenital and hereditary anomalies of the kidneys and urinary collecting systems. Patients with AMT should, therefore, be extensively examined for the presence of occult nephrouropathies.

  8. Understanding commercial truck drivers' decision-makin process concerning distracted driving.

    Science.gov (United States)

    Swedler, David I; Pollack, Keshia M; Gielen, Andrea C

    2015-05-01

    A concurrent mixed methods design was used to explore personal and workplace factors, informed by the Theory of Planned Behavior, that affect truck drivers' decision-making about distracted driving on the job. Qualitative data were collected via semi-structured interviews with experts in truck safety and distracted driving, and quantitative data were collected via online survey of truck drivers in the United States. Findings from the interviews illustrated how drivers perceived distractions and the importance of supervisors enforcing organizational distracted driving policies. Survey results found that behavioral intentions were most important in regards to texting and crash and near-crash outcomes, while perceived norms from management best described the correlation between dispatch device use and negative crash-related outcomes. By using a mixed methods design, rather than two separate studies, these findings revealed nuanced differences into the influence of supervisors on distracted driving. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Mitogenic activation of B cells in vitro: the properties of adherent accessory cells as revealed by partition analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kettman, J.R.; Soederberg, A.; Lefkovits, I.

    1986-08-15

    The requirement of B cells activated by mitogen (dextran sulfate plus lipopolysaccharide) for accessory cells was studied by partition analysis. Small numbers of splenic B cells were activated to clonal growth, as determined by visual inspection, and to immunoglobulin (Ig) synthesis, as determined by release of Ig into the culture fluid. By placing irradiated adherent cells in the periphery of the microculture wells and forcing responding cells to different areas of the well (slant experiments), it was observed that no cell contact was necessary for B cell activation, and that promoted contact (Rock and Roll experiments) does not increase the efficiency of activation. Sequential microcultures suggest that only some irradiated adherent cells act as accessory cells, but they can perform this function to more than one B cell. Attempts to perform limiting dilution analysis by varying irradiated adherent cell input showed non-single-hit behavior. When the data were rearranged, taking into account the distribution of irradiated adherent cells, then single-hit behavior with about 1 to 5% of irradiated adherent cells acting as an accessory cells for B cell clonal activation was observed. The evidence suggests that an uncommon irradiated adherent cell releases a soluble factor necessary for B cell activation and/or clonal proliferation.

  10. Mitogenic activation of B cells in vitro: the properties of adherent accessory cells as revealed by partition analysis

    International Nuclear Information System (INIS)

    Kettman, J.R.; Soederberg, A.; Lefkovits, I.

    1986-01-01

    The requirement of B cells activated by mitogen (dextran sulfate plus lipopolysaccharide) for accessory cells was studied by partition analysis. Small numbers of splenic B cells were activated to clonal growth, as determined by visual inspection, and to immunoglobulin (Ig) synthesis, as determined by release of Ig into the culture fluid. By placing irradiated adherent cells in the periphery of the microculture wells and forcing responding cells to different areas of the well (slant experiments), it was observed that no cell contact was necessary for B cell activation, and that promoted contact (Rock and Roll experiments) does not increase the efficiency of activation. Sequential microcultures suggest that only some irradiated adherent cells act as accessory cells, but they can perform this function to more than one B cell. Attempts to perform limiting dilution analysis by varying irradiated adherent cell input showed non-single-hit behavior. When the data were rearranged, taking into account the distribution of irradiated adherent cells, then single-hit behavior with about 1 to 5% of irradiated adherent cells acting as an accessory cells for B cell clonal activation was observed. The evidence suggests that an uncommon irradiated adherent cell releases a soluble factor necessary for B cell activation and/or clonal proliferation

  11. [Blockade of the pheromonal effects in rat by central deafferentation of the accessory olfactory system].

    Science.gov (United States)

    Sánchez-Criado, J E

    1979-06-01

    Female rats reared without sex odours from male rats have a five day stral cycle. With exposure to male odour the estral cycle is shortened from five to four days. This pheromonal effect is blocked on deafferenting the vomeronasal system by electrolytically damaging both accessory olfactory bulbs.

  12. A Transformerless Medium Voltage Multiphase Motor Drive System

    Directory of Open Access Journals (Sweden)

    Dan Wang

    2016-04-01

    Full Text Available A multiphase motor has several major advantages, such as high reliability, fault tolerance, and high power density. It is a critical issue to develop a reliable and efficient multiphase motor drive system. In this paper, a transformerless voltage source converter-based drive system for a medium-voltage (MV multiphase motor is proposed. This drive converter employs cascaded H-bridge rectifiers loaded by H-bridge inverters as the interface between the grid and multiphase motor. The cascaded H-bridge rectifier technique makes the drive system able to be directly connected to the MV grid without the phase-shifting transformer because it can offset the voltage level gap between the MV grid and the semiconductor devices, provide near-sinusoidal AC terminal voltages without filters, and draw sinusoidal line current from the grid. Based on a digital signal processor (DSP, a complete improved Phase Disposition Pulse Width Modulation (PD-PWM method is developed to ensure the individual DC-link capacitor voltage balancing for enhancing the controllability and limiting the voltage and power stress on the H-bridge cells. A downscaled prototype is designed and developed based on a nine-phase motor. The experimental results verify the excellent performances of the proposed drive system and control strategy in steady-state and variant-frequency startup operations.

  13. Accessory pathway location affects brain natriuretic peptide level in patients with Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Nakatani, Yosuke; Kumagai, Koji; Naito, Shigeto; Nakamura, Kohki; Minami, Kentaro; Nakano, Masahiro; Sasaki, Takehito; Kinugawa, Koichiro; Oshima, Shigeru

    2017-01-01

    The purpose of this study was to investigate the relationship between the accessory pathway location and brain natriuretic peptide (BNP) level in patients with Wolff-Parkinson-White (WPW) syndrome. We divided 102 WPW syndrome patients with normal left ventricular systolic function into four groups: those with manifest right (MR, n = 14), manifest septal (MS, n = 11), manifest left (ML, n = 30), and concealed (C, n = 47) accessory pathways. BNP level and electrophysiological properties, including difference in timing of the ventricular electrogram between the His bundle area and the distal coronary sinus area (His-CS delay), which indicate intraventricular dyssynchrony, were compared. BNP levels (pg/dl) were higher in the MR and MS groups than in the ML and C groups (MR, 64 ± 58; MS, 55 ± 45; ML, 17 ± 15; C, 25 ± 21; P syndrome patients with normal cardiac function.

  14. Uranium in accessory sphene from granitoids and its behaviour during mineral's alteration (Muzbekskij pluton at Mogol-Tau, Central Asia)

    International Nuclear Information System (INIS)

    Simonova, L.I.; Maksimova, I.G.; Nad'yarnykh, V.G.; Voronikhin, V.A.

    1982-01-01

    Uranium behaviour in accessory spbene and products of its alteration at different stages of granitoid transformation with characteristic association of zirconium-apatite-sphene and magnetite of accessory minerals, is shown. The products of sphene alteration (due to propylitization of granatoids the sphene is replaced by leucoxene) are determined by MS-46 electron probe microanalyzer and MA-1 lazer microanalyzer. Uranium distribution in leucoxene is studied by the method of fragmentary radiography. Leucoxene pseudomorphoses at a high oxygen potential are capable of giving into solution Uranium previously sorbed by leucoxene. This fact should be taken into account when determining source of metal of hydrogenous deposits

  15. Age differences in the takeover of vehicle control and engagement in non-driving-related activities in simulated driving with conditional automation.

    Science.gov (United States)

    Clark, Hallie; Feng, Jing

    2017-09-01

    High-level vehicle automation has been proposed as a valuable means to enhance the mobility of older drivers, as older drivers experience age-related declines in many cognitive functions that are vital for safe driving. Recent research attempted to examine age differences in how engagement in non-driving-related activities impact driving performance, by instructing drivers to engage in mandatory pre-designed activities. While the mandatory engagement method allows a precise control of the timing and mental workload of the non-driving-related activities, it is different from how a driver would naturally engage in these activities. This study allowed younger (age 18-35, mean age=19.9years) and older drivers (age 62-81, mean age=70.4years) to freely decide when and how to engage in voluntarily chosen non-driving-related activities during simulated driving with conditional automation. We coded video recordings of participants' engagement in non-driving-related activities. We examined the effect of age, level of activity-engagement and takeover notification interval on vehicle control performance during the takeover, by comparing between the high and low engagement groups in younger and older drivers, across two takeover notification interval conditions. We found that both younger and older drivers engaged in various non-driving-related activities during the automated driving portion, with distinct preferences on the type of activity for each age group (i.e., while younger drivers mostly used an electronic device, older drivers tended to converse). There were also significant differences between the two age groups and between the two notification intervals on various driving performance measures. Older drivers benefited more than younger drivers from the longer interval in terms of response time to notifications. Voluntary engagement in non-driving-related activities did not impair takeover performance in general, although there was a trend of older drivers who were

  16. Bidirectional DC-DC converter fed drive for electric vehicle system ...

    African Journals Online (AJOL)

    Batteries are the primary energy-storage devices in ground vehicles. Now days battery fed electric drives are commonly being used for electric vehicles applications, due to various advantages, such as: nearly zero emission, guaranteed load leveling, good transient operation and energy recovery during braking operation.

  17. Precision alignment device

    Science.gov (United States)

    Jones, N.E.

    1988-03-10

    Apparatus for providing automatic alignment of beam devices having an associated structure for directing, collimating, focusing, reflecting, or otherwise modifying the main beam. A reference laser is attached to the structure enclosing the main beam producing apparatus and produces a reference beam substantially parallel to the main beam. Detector modules containing optical switching devices and optical detectors are positioned in the path of the reference beam and are effective to produce an electrical output indicative of the alignment of the main beam. This electrical output drives servomotor operated adjustment screws to adjust the position of elements of the structure associated with the main beam to maintain alignment of the main beam. 5 figs.

  18. KNOW-Blade Task-2 report - Aerodynamic accessories[Wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Johansen, J.; Soerensen, N.N.; Zahle, F.; Kang, S.; Nikolaou, I.; Politis, E.S.; Chaviaropoulos, P.K.; Ekaterinaris, J.

    2004-11-01

    In the EC project KNOW-BLADE a work package has been defined to investigate the possibility to numerically model aerodynamic accessories in existing Navier-Stokes solvers. Four different aerodynamic accessories have been investigated. Firstly, the potential of applying active flow control by means of a pulsating jet placed at the leading edge in order to enhance mean lift. The general trend is that increased pulsation frequency is beneficial, in that it reduces the oscillation amplitude and raises the mean lift level while lowering the mean drag level. An increased jet exit velocity has a tendency to increase the oscillation amplitude, which is not very attractive for load control on wind turbines. Secondly, the effect of vortex generators has been modelled using two phenomenological vortex generator models. The models have been applied to three airfoil configurations. For all cases investigated the models shows qualitatively the correct behaviour, even though there are a considerable spread in the degree of success. Thirdly, the influence of adding a stall strip for changing the airfoil characteristics was investigated. Stall strips at three different positions were directly modelled by changing the airfoil geometry. In general the 7mm stall strips placed at P00 and P-02 had the greatest effect on the max lift followed by stall strip P02. Unfortunately, there was not sufficient agreement between the experimental results and the simulations to draw any conclusions of optimum position and geometry of the stall strip. Finally, the effect of surface roughness was modelled by either modifying the boundary condition of the turbulence model or by modifying the airfoil geometry. Using the roughness model gave relatively good agreement with measurements and it must be concluded that the effect of using roughness tape can be better predicted with a roughness model compared to using a modified airfoil surface. (au)

  19. Cutaneous application of an accessory-gland secretion after sperm exchange in a terrestrial slug (Mollusca : Pulmonata)

    NARCIS (Netherlands)

    Benke, Mandy; Reise, Heike; Montagne-Wajer, Kora; Koene, Joris M

    Competition for fertilisation in hermaphroditic animals seems to have led to many odd behaviours and complex morphologies involved in the transfer of accessory-gland products to the partner. Terrestrial slugs of the genus Deroceras show remarkably elaborate and interspecifically diverse penis

  20. CMOS On-Chip Optoelectronic Neural Interface Device with Integrated Light Source for Optogenetics

    International Nuclear Information System (INIS)

    Sawadsaringkarn, Y; Kimura, H; Maezawa, Y; Nakajima, A; Kobayashi, T; Sasagawa, K; Noda, T; Tokuda, T; Ohta, J

    2012-01-01

    A novel optoelectronic neural interface device is proposed for target applications in optogenetics for neural science. The device consists of a light emitting diode (LED) array implemented on a CMOS image sensor for on-chip local light stimulation. In this study, we designed a suitable CMOS image sensor equipped with on-chip electrodes to drive the LEDs, and developed a device structure and packaging process for LED integration. The prototype device produced an illumination intensity of approximately 1 mW with a driving current of 2.0 mA, which is expected to be sufficient to activate channelrhodopsin (ChR2). We also demonstrated the functions of light stimulation and on-chip imaging using a brain slice from a mouse as a target sample.

  1. A validation study comparing self-reported travel diaries and objective data obtained from in-vehicle monitoring devices in older drivers with bilateral cataract.

    Science.gov (United States)

    Agramunt, Seraina; Meuleners, Lynn; Chow, Kyle Chi; Ng, Jonathon Q; Morlet, Nigel

    2017-09-01

    Advances in technology have made it possible to examine real-world driving using naturalistic data obtained from in-vehicle monitoring devices. These devices overcome the weaknesses of self-report methods and can provide comprehensive insights into driving exposure, habits and practices of older drivers. The aim of this study is to compare self-reported and objectively measured driving exposure, habits and practices using a travel diary and an in-vehicle driver monitoring device in older drivers with bilateral cataract. A cross-sectional study was undertaken. Forty seven participants aged 58-89 years old (mean=74.1; S.D.=7.73) were recruited from three eye clinics over a one year period. Data collection consisted of a cognitive test, a researcher-administered questionnaire, a travel diary and an in-vehicle monitoring device. Participants' driving exposure and patterns were recorded for one week using in-vehicle monitoring devices. They also completed a travel diary each time they drove a motor vehicle as the driver. Paired t-tests were used to examine differences/agreement between the two instruments under different driving circumstances. The data from the older drivers' travel diaries significantly underestimated the number of overall trips (ptravel diaries also significantly overestimated overall driving duration (ptravelled under any of the driving circumstances. The results of this study found that relying solely on self-reported travel diaries to assess driving outcomes may not be accurate, particularly for estimates of the number of trips made and duration of trips. The clear advantages of using in-vehicle monitoring devices over travel diaries to monitor driving habits and exposure among an older population are evident. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Glaucoma and Driving: On-Road Driving Characteristics

    Science.gov (United States)

    Wood, Joanne M.; Black, Alex A.; Mallon, Kerry; Thomas, Ravi; Owsley, Cynthia

    2016-01-01

    Purpose To comprehensively investigate the types of driving errors and locations that are most problematic for older drivers with glaucoma compared to those without glaucoma using a standardized on-road assessment. Methods Participants included 75 drivers with glaucoma (mean = 73.2±6.0 years) with mild to moderate field loss (better-eye MD = -1.21 dB; worse-eye MD = -7.75 dB) and 70 age-matched controls without glaucoma (mean = 72.6 ± 5.0 years). On-road driving performance was assessed in a dual-brake vehicle by an occupational therapist using a standardized scoring system which assessed the types of driving errors and the locations where they were made and the number of critical errors that required an instructor intervention. Driving safety was rated on a 10-point scale. Self-reported driving ability and difficulties were recorded using the Driving Habits Questionnaire. Results Drivers with glaucoma were rated as significantly less safe, made more driving errors, and had almost double the rate of critical errors than those without glaucoma. Driving errors involved lane positioning and planning/approach, and were significantly more likely to occur at traffic lights and yield/give-way intersections. There were few between group differences in self-reported driving ability. Conclusions Older drivers with glaucoma with even mild to moderate field loss exhibit impairments in driving ability, particularly during complex driving situations that involve tactical problems with lane-position, planning ahead and observation. These results, together with the fact that these drivers self-report their driving to be relatively good, reinforce the need for evidence-based on-road assessments for evaluating driving fitness. PMID:27472221

  3. Glaucoma and Driving: On-Road Driving Characteristics.

    Directory of Open Access Journals (Sweden)

    Joanne M Wood

    Full Text Available To comprehensively investigate the types of driving errors and locations that are most problematic for older drivers with glaucoma compared to those without glaucoma using a standardized on-road assessment.Participants included 75 drivers with glaucoma (mean = 73.2±6.0 years with mild to moderate field loss (better-eye MD = -1.21 dB; worse-eye MD = -7.75 dB and 70 age-matched controls without glaucoma (mean = 72.6 ± 5.0 years. On-road driving performance was assessed in a dual-brake vehicle by an occupational therapist using a standardized scoring system which assessed the types of driving errors and the locations where they were made and the number of critical errors that required an instructor intervention. Driving safety was rated on a 10-point scale. Self-reported driving ability and difficulties were recorded using the Driving Habits Questionnaire.Drivers with glaucoma were rated as significantly less safe, made more driving errors, and had almost double the rate of critical errors than those without glaucoma. Driving errors involved lane positioning and planning/approach, and were significantly more likely to occur at traffic lights and yield/give-way intersections. There were few between group differences in self-reported driving ability.Older drivers with glaucoma with even mild to moderate field loss exhibit impairments in driving ability, particularly during complex driving situations that involve tactical problems with lane-position, planning ahead and observation. These results, together with the fact that these drivers self-report their driving to be relatively good, reinforce the need for evidence-based on-road assessments for evaluating driving fitness.

  4. Glaucoma and Driving: On-Road Driving Characteristics.

    Science.gov (United States)

    Wood, Joanne M; Black, Alex A; Mallon, Kerry; Thomas, Ravi; Owsley, Cynthia

    2016-01-01

    To comprehensively investigate the types of driving errors and locations that are most problematic for older drivers with glaucoma compared to those without glaucoma using a standardized on-road assessment. Participants included 75 drivers with glaucoma (mean = 73.2±6.0 years) with mild to moderate field loss (better-eye MD = -1.21 dB; worse-eye MD = -7.75 dB) and 70 age-matched controls without glaucoma (mean = 72.6 ± 5.0 years). On-road driving performance was assessed in a dual-brake vehicle by an occupational therapist using a standardized scoring system which assessed the types of driving errors and the locations where they were made and the number of critical errors that required an instructor intervention. Driving safety was rated on a 10-point scale. Self-reported driving ability and difficulties were recorded using the Driving Habits Questionnaire. Drivers with glaucoma were rated as significantly less safe, made more driving errors, and had almost double the rate of critical errors than those without glaucoma. Driving errors involved lane positioning and planning/approach, and were significantly more likely to occur at traffic lights and yield/give-way intersections. There were few between group differences in self-reported driving ability. Older drivers with glaucoma with even mild to moderate field loss exhibit impairments in driving ability, particularly during complex driving situations that involve tactical problems with lane-position, planning ahead and observation. These results, together with the fact that these drivers self-report their driving to be relatively good, reinforce the need for evidence-based on-road assessments for evaluating driving fitness.

  5. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  6. Impact of mobile phone use on driving performance - Review of experimental literature, chapter 17. In Driver Distraction and Inattention : Advances in Research and Countermeasures, Volume 1

    OpenAIRE

    BRUYAS, Marie-Pierre

    2013-01-01

    The mobile phone is a technological device that can be used for a variety of purposes - to converse, to exchange text messages, to access the internet, to play games and so on. There has been much research on the impact of using a mobile phone while driving on driving performance - in the laboratory, on test-tracks and on real roads - and there is ample evidence that using this device while driving has adverse effects on driving performance. In this chapter, literature on the impact of mobile...

  7. Device for contamination monitoring against radiation contamination of people

    International Nuclear Information System (INIS)

    Rische, U.W.; Gerlach, R.

    1986-01-01

    The monitor has detector devices at an angle to each other made as a rigid component which can be rotated around a vertical axis in the angle between the joined detector devices. A reset drive which can be tensioned is provided at the axis of rotation. If it is in its rest position, a platform is situated as floor plate with a foot detector between the vertical detector devices. (orig./HP) [de

  8. Two wheel speed robust sliding mode control for electric vehicle drive

    Directory of Open Access Journals (Sweden)

    Abdelfatah Nasri

    2008-01-01

    Full Text Available Nowadays the uses of electrical power resources are integrated in the modern vehicle motion traction chain so new technologies allow the development of electric vehicles (EV by means of static converters-related electric motors. All mechanical transmission devices are eliminated and vehicle wheel motion can be controlled by means of power electronics. The proposed propulsing system consists of two induction motors (IM that ensure the drive of the two back driving wheels. The proposed control structure-called independent machines- for speed control permit the achievement of an electronic differential. The electronic differential system ensures the robust control of the vehicle behavior on the road. It also allows controlling independently, every driving wheel to turn at different speeds in any curve. This paper presents the study and the sliding mode control strategy of the electric vehicle driving wheels.

  9. Device for swinging a gripper in a refueling machine

    International Nuclear Information System (INIS)

    Saima, Toru; Imada, Takahiko.

    1976-01-01

    Object: To provide a device, which can eliminate runout of a telescopic mast when swung for driving, which can eliminate the necesssity of balancing the mast and which is good in vertical precision. Structure: A toothed wheel having a hole through which a telescopic mast is inserted is meshed with a pinion rotated by a driving device to constitute a driving and transmitting mechanism. A coupling mechanism for coupling the toothed wheel and the telescopic mast comprises a bellows having a suitable lateral rigidity and washers securely fastended to opposite ends of said bellows, the washer being fixed to the lower surface of the toothed wheel and the washer fixed to the telescopic mast, respectively, by means of screws. The coupling mechanism is flexed in response to oscillation of the telescopic mast and has a suitable lateral rigidity to transmit rotational motion of the toothed wheel to the telescopic mast. (Kawakami, Y.)

  10. Uterine-sparing Laparoscopic Resection of Accessory Cavitated Uterine Masses.

    Science.gov (United States)

    Peters, Ann; Rindos, Noah B; Guido, Richard S; Donnellan, Nicole M

    2018-01-01

    To demonstrate surgical techniques utilized during uterine-sparing laparoscopic resections of accessory cavitated uterine masses (ACUMs). ACUMs represent a rare uterine entity observed in premenopausal women suffering from dysmenorrhea and recurrent pelvic pain. The diagnosis is made when an isolated extra-cavitated uterine mass is resected from an otherwise normal appearing uterus with unremarkable endometrial lumen and adnexal structures. Pathologic confirmation requires an accessory cavity lined with endometrial epithelium (and corresponding glands and stroma) filled with chocolate-brown fluid. Adenomyosis must be absent. Although the origin of ACUMs is currently unknown, the most common presentation is a 2-4 cm lateral uterine wall mass at the level of the insertion of the round ligament. Hence it has been hypothesized that gubernaculum dysfunction may be responsible for duplication or persistence of paramesonephric tissue leading to ACUM formation as a new Müllerian anomaly. A stepwise surgical tutorial describing 2 laparoscopic ACUM resections using a narrated video (Canadian Task Force classification III). An academic tertiary care hospital. In this video, we present 2 patients who underwent uterine-sparing laparoscopic resections of their ACUM in order to preserve fertility (Case 1) or avoid the complications and surgical recovery time of a total laparoscopic hysterectomy (Case 2). Case 1 is a 19-year-old, gravida 0, para 0 woman with dysmenorrhea and recurrent pelvic pain who presented for multiple emergency room and outpatient evaluations. Transvaginal ultrasonography was unremarkable except for a 28×30×26mm left lateral uterine mass with peripheral vascular flow that was initially felt to be a leiomyoma or rudimentary uterine horn. MRI imaging, however, demonstrated this mass to be more consistent with an ACUM. This was based on the lack of communication between the lesion and the main uterine cavity exhibited by high T2 signal (compatible with

  11. Surgical treatment of a comminuted articular fracture of the accessory carpal bone in a thoroughbred horse

    International Nuclear Information System (INIS)

    Munroe, G.A.; Cauvin, E.

    1997-01-01

    The clinical, radiographic and ultrasonographic findings in a case ofa comminuted articular fracture of the accessory carpal bone of a thoroughbred chaser are described, and its surgical treatment and aftercare are detailed. The horse made an uneventful recovery and successfully returned to racing

  12. Presence of accessory penis, colonic duplication and several other congenital anomalies in a child: a very rare association.

    Science.gov (United States)

    Chatterjee, Sayan; Mondal, Prabodh Chandra; Pandey, Shashi Bhushan; Achar, Arun

    2014-10-01

    An accessory penis is a very rare anomaly. Only five cases have been reported thus far to our knowledge. We present the case of a child aged 2 years and 10 months who had a penis-like structure (containing phallus and glans) attached to the right buttock. Associated anomalies were a non-communicating type of colonic duplication, a paramedian stenosed anal opening, a horse-shoe kidney, posterior urethral valves, scoliosis of the lumbo-sacral spine, polydactyly and equino-varus deformity of the right foot. As far as we can tell, this is the first report of an accessory penis associated with colonic duplication and other congenital anomalies. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. [Magnetic helicity and current drive in fusion devices]. Final technical report

    International Nuclear Information System (INIS)

    1998-01-01

    The research program focused on two main themes: (i) magnetic helicity and (ii) current drive by low-frequency waves. At first these themes seemed unrelated, but as time progressed, they became interwoven, and ultimately closely connected. A sub-theme is that while the MHD model of a plasma stimulates many intriguing counter-intuitive ideas for creating and sustaining magnetic confinement configurations, usually the crux of these schemes involves some sort of breakdown of MHD, i.e., involves physics which transcends MHD

  14. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  15. Space Drive Physics: Introduction and Next Steps

    Science.gov (United States)

    Millis, M. G.

    Research toward the visionary goal of propellantless ``space drives'' is introduced, covering key physics issues and a listing of roughly 2-dozen approaches. The targeted advantage of a space drive is to circumvent the propellant constraints of rockets and the maneuvering limits of light sails by using the interactions between the spacecraft and its surrounding space for propulsion. At present, the scientific foundations from which to engineer a space drive have not been discovered and, objectively, might be impossible. Although no propulsion breakthroughs appear imminent, the subject has matured to where the relevant questions have been broached and are beginning to be answered. The critical make-break issues include; conservation of momentum, uncertain sources of reaction mass, and the net-external thrusting requirement. Note: space drives are not necessarily faster- than-light devices. Speed limits are a separate, unanswered issue. Relevant unsolved physics includes; the sources and mechanisms of inertial frames, coupling of gravitation and electromagnetism, and the nature of the quantum vacuum. The propulsion approaches span mostly stages 1 through 3 of the scientific method (defining the problem, collecting data, and articulating hypotheses), while some have matured to stage 4 (testing hypotheses). Nonviable approaches include `stiction drives,' `gyroscopic antigravity,' and `lifters.' No attempt is made to gauge the prospects of the remaining approaches. Instead, a list of next-step research questions is derived from the examination of these goals, unknowns, and concepts.

  16. Homology of the Fifth Epibranchial and Accessory Elements of the Ceratobranchials among Gnathostomes: Insights from the Development of Ostariophysans

    Science.gov (United States)

    Carvalho, Murilo; Bockmann, Flávio Alicino; de Carvalho, Marcelo Rodrigues

    2013-01-01

    Epibranchials are among the main dorsal elements of the gill basket in jawed vertebrates (Gnathostomata). Among extant fishes, chondrichthyans most resemble the putative ancestral condition as all branchial arches possess every serially homologous piece. In osteichthyans, a primitive rod-like epibranchial 5, articulated to ceratobranchial 5, is absent. Instead, epibranchial 5 of many actinopterygians is here identified as an accessory element attached to ceratobranchial 4. Differences in shape and attachment of epibranchial 5 in chondrichthyans and actinopterygians raised suspicions about their homology, prompting us to conduct a detailed study of the morphology and development of the branchial basket of three ostariophysans (Prochilodus argenteus, Characiformes; Lophiosilurus alexandri and Pseudoplatystoma corruscans, Siluriformes). Results were interpreted within a phylogenetic context of major gnathostome lineages. Developmental series strongly suggest that the so-called epibranchial 5 of actinopterygians does not belong to the epal series because it shares the same chondroblastic layer with ceratobranchial 4 and its ontogenetic emergence is considerably late. This neomorphic structure is called accessory element of ceratobranchial 4. Its distribution among gnathostomes indicates it is a teleost synapomorphy, occurring homoplastically in Polypteriformes, whereas the loss of the true epibranchial 5 is an osteichthyan synapomorphy. The origin of the accessory element of ceratobranchial 4 appears to have occurred twice in osteichthyans, but it may have a single origin; in this case, the accessory element of ceratobranchial 4 would represent a remnant of a series of elements distally attached to ceratobranchials 1–4, a condition totally or partially retained in basal actinopterygians. Situations wherein a structure is lost while a similar neomorphic element is present may lead to erroneous homology assessments; these can be avoided by detailed morphological and

  17. Accessory soleus muscle: a case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Palaniappan, M. (Leicester Royal Infirmary (United Kingdom). Dept. of Radiology Royal Liverpool Children' s Hospital (United Kingdom). Dept. of Radiology); Rajesh, A.; Rickett, A. (Leicester Royal Infirmary (United Kingdom). Dept. of Radiology); Kershaw, C.J. (Leicester Royal Infirmary (United Kingdom). Dept. of Orthopaedics)

    1999-08-01

    Accessory soleus muscle is a rare condition which presents as a soft-tissue mass medial to the calcaneum and distal Achilles tendon. Though congenital in origin, it manifests in the second and third decades of life as a soft-tissue mass due to muscle hypertrophy. Patients may be asymptomatic or present with a painful ankle mass. It is important to be aware of this condition when interpreting CT or MRI of the ankle, which show characteristic findings of a normal muscle in an abnormal location. (orig.) With 4 figs., 12 refs.

  18. Abnormal Origin and Course of the Accessory Phrenic Nerve: Case Report.

    Science.gov (United States)

    Paraskevas, George; Koutsouflianiotis, Konstantinos; Kitsoulis, Panagiotis; Spyridakis, Ioannis

    In the current cadaveric study an unusual sizeable accessory phrenic nerve (APN) was encountered emerging from the trunk of the supraclavicular nerves and forming a triangular loop that was anastomosing with the phrenic nerve. That neural loop surrounded the superficial cervical artery which displayed a spiral course. The form of a triangular loop of APN involving the aforementioned artery and originating from the supraclavicular nerve to the best of our knowledge has not been documented previously in the literature. The variable morphological features of the APN along with its clinical applications are briefly discussed.

  19. A Simple Sensorless Scheme for Induction Motor Drives Fed by a Matrix Converter Using Constant Air-Gap Flux and PQR Transformation

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Lee, Kyo Beum

    2007-01-01

    This paper presents a new and simple method for sensorless operation of matrix converter drives using a constant air-gap flux and the imaginary power flowing to the motor. To improve low-speed sensorless performance, the non-linearities of a matrix converter drive such as commutation delays, turn......-on and turn-off times of switching devices, and on-state switching device voltage drop are modeled using PQR transformation and compensated using a reference current control scheme. The proposed compensation method is applied for high performance induction motor drives using a 3 kW matrix converter system...

  20. Device for selectively securing an object to a shaft

    International Nuclear Information System (INIS)

    Calizano, F.; Chauvel, M.

    1984-01-01

    A magnetic tape reel is secured to a reel drive motor shaft by a device including a hub secured to the shaft, a plurality of shoes, and actuating means for thrusting the shoes against the reel and for releasing them from contact with the reel. The securing device includes a cam mounted on the shaft in combination with a locking device including the cam periphery. The locking device thrusts the shoes against the object and is operated by rotation of the motor. The cam is immobilized in rotation while the shoes are locked

  1. A field test of substance use screening devices as part of routine drunk-driving spot detection operating procedures in South Africa.

    Science.gov (United States)

    Matzopoulos, Richard; Lasarow, Avi; Bowman, Brett

    2013-10-01

    This pilot study aimed to test four substance use screening devices developed in Germany under local South African conditions and assess their utility for detecting driving under the influence of drugs (DUID) as part of the standard roadblock operations of local law enforcement agencies. The devices were used to screen a sample of motorists in the Gauteng and Western Cape provinces. The motorists were diverted for screening at roadblocks at the discretion of the law enforcement agencies involved, as per their standard operating procedures. Fieldworkers also administered a questionnaire that described the screening procedure, as well as information about vehicles, demographic information about the motorists and their attitudes to the screening process during testing. Motorists tested positive for breath alcohol in 28% of the 261 cases tested. Oral fluid was screened for drugs as per the standard calibrated cut-offs of all four devices. There were 14 cases where the under-influence drivers tested positive for alcohol and drugs simultaneously, but 14% of the 269 drivers drug-screened tested positive for drugs only. After alcohol, amphetamine, methamphetamine and cocaine were the most common drugs of impairment detected. The results suggest that under normal enforcement procedures only 76% of drivers impaired by alcohol and other drugs would have been detected. In more than 70% of cases the tests were administered within 5 min and this is likely to improve with more regular use. It was clear that the pilot screening process meets global testing standards. Although use of the screening devices alone would not serve as a basis for prosecution and provisions would need to be made for the confirmation of results through laboratory testing, rollout of this screening process would improve operational efficiency in at least two ways. Firstly, the accuracy of the tests will substantially decrease confirmatory test loads. Secondly, laboratory drug testing can be restricted to

  2. Melanocortin receptor accessory proteins in adrenal gland physiology and beyond.

    Science.gov (United States)

    Novoselova, T V; Jackson, D; Campbell, D C; Clark, A J L; Chan, L F

    2013-04-01

    The melanocortin receptor (MCR) family consists of five G-protein-coupled receptors (MC1R-MC5R) with diverse physiological roles. MC1R controls pigmentation, MC2R is a critical component of the hypothalamic-pituitary-adrenal axis, MC3R and MC4R have a vital role in energy homeostasis and MC5R is involved in exocrine function. The melanocortin receptor accessory protein (MRAP) and its paralogue MRAP2 are small single-pass transmembrane proteins that have been shown to regulate MCR expression and function. In the adrenal gland, MRAP is an essential accessory factor for the functional expression of the MC2R/ACTH receptor. The importance of MRAP in adrenal gland physiology is demonstrated by the clinical condition familial glucocorticoid deficiency, where inactivating MRAP mutations account for ∼20% of cases. MRAP is highly expressed in both the zona fasciculata and the undifferentiated zone. Expression in the undifferentiated zone suggests that MRAP could also be important in adrenal cell differentiation and/or maintenance. In contrast, the role of adrenal MRAP2, which is highly expressed in the foetal gland, is unclear. The expression of MRAPs outside the adrenal gland is suggestive of a wider physiological purpose, beyond MC2R-mediated adrenal steroidogenesis. In vitro, MRAPs have been shown to reduce surface expression and signalling of all the other MCRs (MC1,3,4,5R). MRAP2 is predominantly expressed in the hypothalamus, a site that also expresses a high level of MC3R and MC4R. This raises the intriguing possibility of a CNS role for the MRAPs.

  3. A formula for efficiency of fast wave current drive in fusion devices

    International Nuclear Information System (INIS)

    Chiu, S.C.; Harvey, R.W.; Karney, C.F.F.; Mau, T.K.

    1992-06-01

    Fast wave current drive (FWCD) is a principal candidate for non- inductive current drive schemes in reactors. Major experiments are in progress or planned on DIII-D, JET, and Tore-Supra. A theory for FWCD was presented by two of the authors and collaborators. To minimize computations required in transport simulations, and for analytical understanding, it is very useful to have a concise analytical efficiency formula. Fisch and Karney, and Ehst and Karney have obtained empirical formulae that fits numerical results for the Landau limit and Alfven limit; the latter fits results at 1 i ≤ 2. This paper extends a previous numerical study on FWCD at arbitrary frequencies and Z i . Analytical formulae for FWCD efficiency, valid for all frequencies and Z i , are derived using the adjoint technique in high and low phase velocity regions. A smooth patching between the two regions produces an analytical formula which is accurate for all frequencies, Z i , and phase velocities. Comparison with existing results will be discussed. A corollary of the present calculation is that a low phase velocities and in the Landau limit, the efficiency is the same as that calculated from the Lorentz model collision operator

  4. Identifying Method of Drunk Driving Based on Driving Behavior

    Directory of Open Access Journals (Sweden)

    Xiaohua Zhao

    2011-05-01

    Full Text Available Drunk driving is one of the leading causes contributing to traffic crashes. There are numerous issues that need to be resolved with the current method of identifying drunk driving. Driving behavior, with the characteristic of real-time, was extensively researched to identify impaired driving behaviors. In this paper, the drives with BACs above 0.05% were defined as drunk driving state. A detailed comparison was made between normal driving and drunk driving. The experiment in driving simulator was designed to collect the driving performance data of the groups. According to the characteristics analysis for the effect of alcohol on driving performance, seven significant indicators were extracted and the drunk driving was identified by the Fisher Discriminant Method. The discriminant function demonstrated a high accuracy of classification. The optimal critical score to differentiate normal from drinking state was found to be 0. The evaluation result verifies the accuracy of classification method.

  5. Lower hybrid current drive: an overview of simulation models, benchmarking with experiment, and predictions for future devices

    International Nuclear Information System (INIS)

    Bonoli, P.T.; Barbato, E.; Imbeaux, F.

    2003-01-01

    This paper reviews the status of lower hybrid current drive (LHCD) simulation and modeling. We first discuss modules used for wave propagation, absorption, and current drive with particular emphasis placed on comparing exact numerical solutions of the Fokker Planck equation in 2-dimension with solution methods that employ 1-dimensional and adjoint approaches. We also survey model predictions for LHCD in past and present experiments showing detailed comparisons between simulated and observed current drive efficiencies and hard X-ray profiles. Finally we discuss several model predictions for lower hybrid current profile control in proposed next step reactor options. (authors)

  6. Clinico-pathologic spectrum of accessory axillary breast; case series and literature review

    Directory of Open Access Journals (Sweden)

    Usman Bello

    2017-01-01

    Full Text Available Accessory breast and the diseases affecting these aberrant breast tissues are relatively uncommon, and with variable prevalence among different populations. These are commonly located in the axilla, chest wall, and vulva. The most common disease in these tissues is carcinoma; however, other benign neoplastic and nonneoplastic lesions do occur. In this review, we present a clinicopathologic analysis of all the consecutive cases seen in a major referral teaching hospital over a period spanning 10 years (2006–2015.

  7. New ergonomic headset for Tongue-Drive System with wireless smartphone interface.

    Science.gov (United States)

    Park, Hangue; Kim, Jeonghee; Huo, Xueliang; Hwang, In-O; Ghovanloo, Maysam

    2011-01-01

    Tongue Drive System (TDS) is a wireless tongue-operated assistive technology (AT), developed for people with severe physical disabilities to control their environment using their tongue motion. We have developed a new ergonomic headset for the TDS with a user-friendly smartphone interface, through which users will be able to wirelessly control various devices, access computers, and drive wheelchairs. This headset design is expected to act as a flexible and multifunctional communication interface for the TDS and improve its usability, accessibility, aesthetics, and convenience for the end users.

  8. Single channel double-duct liquid metal electrical generator using a magnetohydrodynamic device

    Science.gov (United States)

    Haaland, Carsten M.; Deeds, W. Edward

    1999-01-01

    A single channel double-duct liquid metal electrical generator using a magnetohydrodynamic (MHD) device. The single channel device provides useful output AC electric energy. The generator includes a two-cylinder linear-piston engine which drives liquid metal in a single channel looped around one side of the MHD device to form a double-duct contra-flowing liquid metal MHD generator. A flow conduit network and drive mechanism are provided for moving liquid metal with an oscillating flow through a static magnetic field to produce useful AC electric energy at practical voltages and currents. Variable stroke is obtained by controlling the quantity of liquid metal in the channel. High efficiency is obtained over a wide range of frequency and power output.

  9. A Co-modeling Method Based on Component Features for Mechatronic Devices in Aero-engines

    Science.gov (United States)

    Wang, Bin; Zhao, Haocen; Ye, Zhifeng

    2017-08-01

    Data-fused and user-friendly design of aero-engine accessories is required because of their structural complexity and stringent reliability. This paper gives an overview of a typical aero-engine control system and the development process of key mechatronic devices used. Several essential aspects of modeling and simulation in the process are investigated. Considering the limitations of a single theoretic model, feature-based co-modeling methodology is suggested to satisfy the design requirements and compensate for diversity of component sub-models for these devices. As an example, a stepper motor controlled Fuel Metering Unit (FMU) is modeled in view of the component physical features using two different software tools. An interface is suggested to integrate the single discipline models into the synthesized one. Performance simulation of this device using the co-model and parameter optimization for its key components are discussed. Comparison between delivery testing and the simulation shows that the co-model for the FMU has a high accuracy and the absolute superiority over a single model. Together with its compatible interface with the engine mathematical model, the feature-based co-modeling methodology is proven to be an effective technical measure in the development process of the device.

  10. Care of astronomical telescopes and accessories a manual for the astronomical observer and amateur telescope maker

    CERN Document Server

    Pepin, M Barlow

    2005-01-01

    Commercially-made astronomical telescopes are better and less expensive than ever before, and their optical and mechanical performance can be superb. When a good-quality telescope fails to perform as well as it might, the reason is quite probably that it needs a little care and attention! Here is a complete guide for anyone who wants to understand more than just the basics of astronomical telescopes and accessories, and how to maintain them in the peak of condition. The latest on safely adjusting, cleaning, and maintaining your equipment is combined with thoroughly updated methods from the old masters. Here, too, are details of choosing new and used optics and accessories, along with enhancements you can make to extend their versatility and useful lifetime. This book is for you. Really. Looking after an astronomical telescope isn't only for the experts - although there are some things that only an expert should attempt - and every serious amateur astronomer will find invaluable information here, gleaned from ...

  11. Electromagnetic device of linear displacement

    International Nuclear Information System (INIS)

    Savary, F.; Le Saulnier, G.

    1986-01-01

    The device moves a rod integral with a nuclear reactor control element. It has a grab for the rod operated by a mobil pole drive by a coil carried by a surrounding sealed casing, a second grab with fixed and mobile poles with facing surfaces shaped to limit the variation of magnetic force with distance between them, and a plunger driven by a coil to bear against another mobile pole moved by a coil. The invention proposes a device ensuring a displacement while the impact forces at the different level of the mechanism are reduced [fr

  12. Assembly For Moving a Robotic Device Along Selected Axes

    Science.gov (United States)

    Nowlin, Brentley Craig (Inventor); Koch, Lisa Danielle (Inventor)

    2001-01-01

    An assembly for moving a robotic device along selected axes includes a programmable logic controller (PLC) for controlling movement of the device along selected axes to effect movement of the device to a selected disposition. The PLC includes a plurality of single axis motion control modules, and a central processing unit (CPU) in communication with the motion control modules. A human-machine interface is provided for operator selection of configurations of device movements and is in communication with the CPU. A motor drive is in communication with each of the motion control modules and is operable to effect movement of the device along the selected axes to obtain movement of the device to the selected disposition.

  13. A device for external γ-irradiation of experimental animals

    International Nuclear Information System (INIS)

    Ivanitskaya, N.F.; Talakin, Yu.N.; Lekakh, V.A.

    1992-01-01

    A device was developed for external gamma-irradiation of experimental animals including a radiation source, a device for fixation of the total animal or a segment of its body in the focus of irradiation, and a shilding screen. To widen the sphere of this device application by making possible a simultaneous radiation exposure of a group of animals under various radiation schedules, the device involves two discs with a common axis. The lower disc is provided with an electric drive and containers with animals are placed on it, and the upper disc is for the shielding screen. The device is supplied with an operation block

  14. Development of an innovative device for ultrasonic elliptical vibration cutting.

    Science.gov (United States)

    Zhou, Ming; Hu, Linhua

    2015-07-01

    An innovative ultrasonic elliptical vibration cutting (UEVC) device with 1st resonant mode of longitudinal vibration and 3rd resonant mode of bending vibration was proposed in this paper, which can deliver higher output power compared to previous UEVC devices. Using finite element method (FEM), resonance frequencies of the longitudinal and bending vibrations were tuned to be as close as possible in order to excite these two vibrations using two-phase driving voltages at a single frequency, while wave nodes of the longitudinal and bending vibrations were also adjusted to be as coincident as possible for mounting the device at a single fixed point. Based on the simulation analysis results a prototype device was fabricated, then its vibration characteristics were evaluated by an impedance analyzer and a laser displacement sensor. With two-phase sinusoidal driving voltages both of 480 V(p-p) at an ultrasonic frequency of 20.1 kHz, the developed prototype device achieved an elliptical vibration with a longitudinal amplitude of 8.9 μm and a bending amplitude of 11.3 μm. The performance of the developed UEVC device is assessed by the cutting tests of hardened steel using single crystal diamond tools. Experimental results indicate that compared to ordinary cutting process, the tool wear is reduced significantly by using the proposed device. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Self-rated driving and driving safety in older adults.

    Science.gov (United States)

    Ross, Lesley A; Dodson, Joan E; Edwards, Jerri D; Ackerman, Michelle L; Ball, Karlene

    2012-09-01

    Many U.S. states rely on older adults to self-regulate their driving and determine when driving is no longer a safe option. However, the relationship of older adults' self-rated driving in terms of actual driving competency outcomes is unclear. The current study investigates self-rated driving in terms of (1) systematic differences between older adults with high (good/excellent) versus low (poor/fair/average) self-ratings, and (2) the predictive nature of self-rated driving to adverse driving outcomes in older adults (n=350; mean age 73.9, SD=5.25, range 65-91). Adverse driving outcomes included self-reported incidences of (1) being pulled over by the police, (2) receiving a citation, (3) receiving a recommendation to cease or limit driving, (4) crashes, and (5) state-reported crashes. Results found that older drivers with low self-ratings reported more medical conditions, less driving frequency, and had been given more suggestions to stop/limit their driving; there were no other significant differences between low and high self-raters. Logistic regression revealed older drivers were more likely to have a state-reported crash and receive a suggestion to stop or limit driving. Men were more likely to report all adverse driving outcomes except for receiving a suggestion to stop or limit driving. Regarding self-rated driving, older adults with high ratings were 66% less likely (OR=0.34, 95% CI=0.14-0.85) to have received suggestions to limit or stop driving after accounting for demographics, health and driving frequency. Self-ratings were not predictive of other driving outcomes (being pulled over by the police, receiving a citation, self-reported crashes, or state-reported crashes, ps>0.05). Most older drivers (85.14%) rated themselves as either good or excellent drivers regardless of their actual previous citation or crash rates. Self-rated driving is likely not related to actual driving proficiency as indicated by previous crash involvement in older adults

  16. Can an accessory renal artery be safely covered during endovascular aortic aneurysm repair?

    OpenAIRE

    Antoniou, George A.; Karkos, Christos D.; Antoniou, Stavros A.; Georgiadis, George S.

    2013-01-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether coverage of an accessory renal artery (ARA) in patients undergoing endovascular aortic aneurysm repair (EVAR) is associated with increased risk of renal impairment. Altogether, 106 papers were located using the reported searches, of which 5 represented the best evidence to answer the question. The authors, journal, date and country of publication, study type, patient group studied, rel...

  17. The Drive-Wise Project: Driving Simulator Training increases real driving performance in healthy older drivers

    Directory of Open Access Journals (Sweden)

    Gianclaudio eCasutt

    2014-05-01

    Full Text Available Background: Age-related cognitive decline is often associated with unsafe driving behavior. We hypothesized that 10 active training sessions in a driving simulator increase cognitive and on-road driving performance. In addition, driving simulator training should outperform cognitive training.Methods: Ninety-one healthy active drivers (62 – 87 years were randomly assigned to either (1 a driving simulator training group, (2 an attention training group (vigilance and selective attention, or (3 a control group. The main outcome variables were on-road driving and cognitive performance. Seventy-seven participants (85% completed the training and were included in the analyses. Training gains were analyzed using a multiple regression analysis with planned comparisons.Results: The driving simulator training group showed an improvement in on-road driving performance compared to the attention training group. In addition, both training groups increased cognitive performance compared to the control group. Conclusion: Driving simulator training offers the potential to enhance driving skills in older drivers. Compared to the attention training, the simulator training seems to be a more powerful program for increasing older drivers’ safety on the road.

  18. 15 CFR 742.11 - Specially designed implements of torture, thumbscrews, and thumbcuffs; and parts and accessories...

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Specially designed implements of torture, thumbscrews, and thumbcuffs; and parts and accessories, n.e.s. 742.11 Section 742.11 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND...

  19. Screwing or unscrewing device for studs or bolls of big dimension

    International Nuclear Information System (INIS)

    Sevelinge, G.; Bourdonne, J.C.

    1988-01-01

    The device for screwing or unscrewing large studs or bolts has a system determining the optimun screwing position and orientation of the bolt, a variable speed bidirectional drive a pin holding the bolt axially and system compensating the weight of the bolt with an hydraulic jack with a pressure detector to which the drive is slaved [fr

  20. Electrical drives for direct drive renewable energy systems

    CERN Document Server

    Mueller, Markus

    2013-01-01

    Wind turbine gearboxes present major reliability issues, leading to great interest in the current development of gearless direct-drive wind energy systems. Offering high reliability, high efficiency and low maintenance, developments in these direct-drive systems point the way to the next generation of wind power, and Electrical drives for direct drive renewable energy systems is an authoritative guide to their design, development and operation. Part one outlines electrical drive technology, beginning with an overview of electrical generators for direct drive systems. Principles of electrical design for permanent magnet generators are discussed, followed by electrical, thermal and structural generator design and systems integration. A review of power electronic converter technology and power electronic converter systems for direct drive renewable energy applications is then conducted. Part two then focuses on wind and marine applications, beginning with a commercial overview of wind turbine drive systems and a...

  1. Self-rated Driving and Driving Safety in Older Adults

    OpenAIRE

    Ross, Lesley A.; Dodson, Joan; Edwards, Jerri D.; Ackerman, Michelle L.; Ball, Karlene

    2012-01-01

    Many U.S. states rely on older adults to self-regulate their driving and determine when driving is no longer a safe option. However, the relationship of older adults’ self-rated driving in terms of actual driving competency outcomes is unclear. The current study investigates self-rated driving in terms of (1) systematic differences between older adults with high (good/excellent) versus low (poor/fair/average) self-ratings, and (2) the predictive nature of self-rated driving to adverse driving...

  2. Take-up device for incore instruments for nuclear power plant

    International Nuclear Information System (INIS)

    Watanabe, Shigeru.

    1978-01-01

    Purpose: To obtain a take-up device being capable of loading through the control rod inlet and operating with ease on a control rod exchange platform by detacheably mounting a reel-containing cask to a truck carrying a spool driving motor. Constitution: A take-up device is located while running a truck along guide rails from control rod inlet. A cask door is opened on a control rod exchange platform and a compression coupling tube is connected to the lower end of an instrument. Thereafter, a spool is rotated by a driving motor and a detection tube is taken up and wound into a spool through a take-up port. (Yoshino, Y.)

  3. Improvement of fuel sampling device for STACY and TRACY

    International Nuclear Information System (INIS)

    Hirose, Hideyuki; Sakuraba, Koichi; Onodera, Seiji

    1998-05-01

    STACY and TRACY, static and transient experiment facilities in NUCEF, use solution fuel. It is important to analyze accurately fuel composition (uranium enrichment, uranium concentration, nitric acid morality, amount of impurities, radioactivity of FP) for their safety operation and improvement of experimental accuracy. Both STACY and TRACY have the sampling devices to sample fuel solution for that purpose. The previous sampling devices of STACY and TRACY had been designed to dilute fuel sample with nitric acid. Its sampling mechanism could pour fuel sample into sampling vessel by a piston drive of nitric acid in the burette. It was, however, sometimes found that sample fuel solution was diluted by mixing with nitric acid in the burette. Therefore, the sampling mechanism was change into a fixed quantity pump drive which didn't use nitric acid. The authors confirmed that the performance of the new sampling device was improved by changing sampling mechanism. It was confirmed through the function test that the uncertainty in uranium concentration measurement using the improved sampling device was 0.14%, and less than the designed value of 0.2% (coefficient of variation). (author)

  4. TOXICOPATHOLOGICAL IMPACT OF CADMIUM CHLORIDE ON THE ACCESSORY RESPIRATORY ORGAN OF THE AIR-BREATHING CATFISH HETEROPNEUSTES FOSSILIS

    Directory of Open Access Journals (Sweden)

    N. Susithra, N. Jothivel, P. Jayakumar, V. I. Paul

    2007-01-01

    Full Text Available Sublethal cadmium chloride (0.3 ppm toxicity induced stress related morphopathological alterations in the accessory respiratory organ of the air-breathing catfish Heteropneustes fossilis (Siluriformes; Heteropneustidae have been investigated at various intervals of exposure. The histopathological manifestation of the cadmium toxicity includes bulging of the hyperemic secondary lamellae into the lumen of the accessory respiratory organ, necrosis and sloughing of the respiratory epithelium leading to haemorrhage and fusion of SL at various stages of the exposure. Periodic alterations in the densities of epithelial cells and mucous cells along with the development of non-tissue spaces have also been noticed at different exposure periods leading to alterations in the thickness of the respiratory epithelia. The heavy metal salt exposure has affected the mucogenic activity of the respiratory epithelium not only quantitatively but qualitatively also, indicating the probable ameliorative role fish mucus in cadmium toxicity.

  5. Magnetoresistance and noise properties of chevron stretcher detectors for field access bubble domain devices

    Science.gov (United States)

    George, P. K.; Oeffinger, T. R.; Chen, T. T.

    1976-01-01

    Experiments were devised to study the angular variation of the resistance and noise properties of one- and two-level chevron stretcher magnetoresistive detectors for use in field access bubble memory devices. All measurements, made with an electronic system, were performed on glass or garnet samples upon which 1 micron of SiO2 was sputter-deposited, followed by 4000 A of Permalloy for the 28-micron-period devices and 0.8 microns of SiO2, followed by 3000 A of Permalloy for the 20-micron-period devices. The geometrical and drive-state dependence of the zero-state noise were studied, as was its frequency dependence. It is found that both types of detectors operate primarily in the amplitude-shift mode for drive fields of interest and that the presence of a bubble in a detector causes a magnetoresistance change equal to that produced by increasing the in-plane drive field about 8 Oe in the absence of a bubble.

  6. A rare case of fibrocystic disease at vulval accessory breast tissue.

    Science.gov (United States)

    Das, Sudip; Roy, Alok Kumar; Kar, Chinmoy; Giri, Parag Prasun

    2007-11-01

    A 40-year-old female presented with a non-itchy ulcerative nodular lesion at left labium majus since last 1 1/2 years. The lesion progressed to increase in size from 0.5 cm to 1.5 cm in diameter. It was incised and drained. After that a non-healing ulcerative nodule formed. The nodule was firm in consistency and movable on all sides. The ulcer healed with a 5 days course of ceftriaxone. If was excised and biopsy of the lesion showed fibrocystic changes of accessory breast tissue. It is a rare disease entity for which the case report is presented.

  7. Abnormal Origin and Course of the Accessory Phrenic Nerve: Case Report

    Directory of Open Access Journals (Sweden)

    George Paraskevas

    2016-08-01

    Full Text Available In the current cadaveric study an unusual sizeable accessory phrenic nerve (APN was encountered emerging from the trunk of the supraclavicular nerves and forming a triangular loop that was anastomosing with the phrenic nerve. That neural loop surrounded the superficial cervical artery which displayed a spiral course. The form of a triangular loop of APN involving the aforementioned artery and originating from the supraclavicular nerve to the best of our knowledge has not been documented previously in the literature. The variable morphological features of the APN along with its clinical applications are briefly discussed.

  8. Group traction drive as means to increase energy efficiency of lokomotives of open-pit transport

    Science.gov (United States)

    Antipin, D. Ya; Izmerov, O. V.; Bishutin, S. G.; Kobishchanov, V. V.

    2017-10-01

    Questions of possible use of a group drive for locomotives of an open-pit transport are considered. The possibility of a significant reduction of traction costs in the case of a combination of a group traction drive with devices for the non-inertial regulation of the coefficient of friction between the wheel and the rail has been shown, and new patentable solutions have been proposed.

  9. Control rod drives for nuclear reactors

    International Nuclear Information System (INIS)

    Okada, Shige.

    1981-01-01

    Purpose: To enable the detection for the raptures of the bellows in control rod drives in LMFBR type reactor, by recycling seal gases inside the bellows and measuring the radioactivity in the recycling passage. Constitution: In the control drives, outer extension pipe is surrounded by the bellows, which is put between the cylindrical biological shieldings around the upper potion of an upper guide tube and the disk-like seal members provided at the lower flange of the outer extension pipe. Thus, the inside device of control rod is isolated from the coolants and the cover gases. The outer extension pipe is provided with a suction channel and a return channel. These channels are connected to a seal gas recycling pipeway, a pump and a radioactivity detector, where the seal gases in the bellows is recycling. If failures should occur in the bellows, cover gas leaks into the seal gas and recycles, whereby radioactivity is detected and alarmed. (J.P.N.)

  10. Left atrial accessory appendages, diverticula, and left-sided septal pouch in multi-slice computed tomography. Association with atrial fibrillation and cerebrovascular accidents.

    Science.gov (United States)

    Hołda, Mateusz K; Koziej, Mateusz; Wszołek, Karolina; Pawlik, Wiesław; Krawczyk-Ożóg, Agata; Sorysz, Danuta; Łoboda, Piotr; Kuźma, Katarzyna; Kuniewicz, Marcin; Lelakowski, Jacek; Dudek, Dariusz; Klimek-Piotrowska, Wiesława

    2017-10-01

    The aim of this study is to provide a morphometric description of the left-sided septal pouch (LSSP), left atrial accessory appendages, and diverticula using cardiac multi-slice computed tomography (MSCT) and to compare results between patient subgroups. Two hundred and ninety four patients (42.9% females) with a mean of 69.4±13.1years of age were investigated using MSCT. The presence of the LSSP, left atrial accessory appendages, and diverticula was evaluated. Multiple logistic regression analysis was performed to check whether the presence of additional left atrial structures is associated with increased risk of atrial fibrillation and cerebrovascular accidents. At least one additional left atrial structure was present in 51.7% of patients. A single LSSP, left atrial diverticulum, and accessory appendage were present in 35.7%, 16.0%, and 4.1% of patients, respectively. After adjusting for other risk factors via multiple logistic regression, patients with LSSP are more likely to have atrial fibrillation (OR=2.00, 95% CI=1.14-3.48, p=0.01). The presence of a LSSP was found to be associated with an increased risk of transient ischemic attack using multiple logistic regression analysis after adjustment for other risk factors (OR=3.88, 95% CI=1.10-13.69, p=0.03). In conclusion LSSPs, accessory appendages, and diverticula are highly prevalent anatomic structures within the left atrium, which could be easily identified by MSCT. The presence of LSSP is associated with increased risk for atrial fibrillation and transient ischemic attack. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Gate length scaling trends of drive current enhancement in CMOSFETs with dual stress overlayers and embedded-SiGe

    International Nuclear Information System (INIS)

    Flachowsky, S.; Wei, A.; Herrmann, T.; Illgen, R.; Horstmann, M.; Richter, R.; Salz, H.; Klix, W.; Stenzel, R.

    2008-01-01

    Strain engineering in MOSFETs using tensile nitride overlayer (TOL) films, compressive nitride overlayer (COL) films, and embedded-SiGe (eSiGe) is studied by extensive device experiments and numerical simulations. The scaling behavior was analyzed by gate length reduction down to 40 nm and it was found that drive current strongly depends on the device dimensions. The reduction of drain-current enhancement for short-channel devices can be attributed to two competing factors: shorter gate length devices have increased longitudinal and vertical stress components which should result in improved drain-currents. However, there is a larger degradation from external resistance as the gate length decreases, due to a larger voltage dropped across the external resistance. Adding an eSiGe stressor reduces the external resistance in the p-MOSFET, to the extent that the drive current improvement from COL continues to increase even down the shortest gate length studied. This is due to the reduced resistivity of SiGe itself and the SiGe valence band offset relative to Si, leading to a smaller silicide-active contact resistance. It demonstrates the advantage of combining eSiGe and COL, not only for increased stress, but also for parasitic resistance reduction to enable better COL drive current benefit

  12. Clinical results of a new strategy (modified CHIVA) for surgical treatment of anterior accessory great saphenous varicose veins.

    Science.gov (United States)

    Maldonado-Fernández, Nicolás; Linares-Palomino, Jose Patricio; López-Espada, Cristina; Martínez-Gámez, Francisco Javier; Ros-Díe, Eduardo

    2016-03-01

    Traditionally, anterior accessory great saphenous vein insufficiency was managed by crossectomy and resection of varicose veins. The aim of this paper is to show the safety and efficacy of a new therapeutic strategy for anterior accessory great saphenous varicose veins. This non-randomised prospective study included 65 patients with varicose veins from the anterior accessory great saphenous vein. The novelty of the technique is to avoid the great saphenous vein crossectomy and perform just flebectomy of the visible veins. Venous duplex studies were performed preoperatively, a month and a year postoperatively. The clinical assessment was done by the Fligelstone scale. The baseline CEAP clinical classification was: 58% C2, 26% C3 and 15% C4-6. The new strategy was applied to all cases. 3 haematomas, 7 cases of asymptomatic partial anterior saphenous thrombosis. Reduction of the initial average diameter was from 6.4 mm anterior saphenous to 3.4 mm by one year (p <0.001). At twelve months a forward flow is maintained in 82% of cases. Recurrence of varicose veins was 8%. All patients improved their clinical status based on the Fligelstone scale. Cases with saphenous diameter bigger than 7.5 mm and obesity were identified as predictors of worse clinical and hemodynamic outcome. This modified surgical strategy for anterior saphenous varicose veins results in better clinical outcomes at one year postoperatively. Copyright © 2015 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Simulation models of a drive with an asynchronous electric engine for students of electrical engineering faculties

    Directory of Open Access Journals (Sweden)

    Romanenko N. G.

    2017-10-01

    Full Text Available the application of virtual laboratories will allow to show different transition processes, as well as to carry out experiments that are very expensive in real electrical machines’ labs, for example, to calculate the energy costs in electric drives. Models of non-regulation asynchronous drive and frequency-regulated asynchronous electric drive are examined in this article. The author has calculated and compared the energy losses of these systems with various types of loads and this lets us to evaluate work processes of many technical devices.

  14. Mobile instrumentation platform and robotic accessory for real-time screening of hazardous waste

    International Nuclear Information System (INIS)

    Anderson, M.S.; Jaselskis, E.J.

    1992-01-01

    An innovative mobile laboratory for real-time field screening of soils for inorganic hazardous waste using laser ablation-inductively coupled plasma-atomic emission spectrometry sampling and analysis technique is being developed at Ames Laboratory. This sampling technique as well as the concept for installing, monitoring, and controlling the instrumentation and utilities in the mobile laboratory, the robotic sampling accessory, and manual sampling method are discussed. Benefits of this mobile configuration and future development plans also are described

  15. HIL Simulation of Power Electronics and Electric Drives for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Frank Puschmann

    2012-12-01

    Full Text Available Hardware-in-the-loop simulation is today a standard method for testing electronic equipment in the automotive industry. Since electric drives and power electronic devices are more and more important in automotive applications, these kinds of systems have to be integrated into the hardware-in-the-loop simulation. Power converters and electric drives are used in many different applications in vehicles today (hybrid electric or electric powertrain, electric steering systems, DC-DC converters, etc.. The wide range of applications, topologies, and power levels results in various different approaches and solutions for hardware-in-the-loop testing. This paper gives an overview of hardware-in-the-loop simulation of power electronics and electric drives in the automotive industry. The currently available technologies are described and future challenges are outlined.

  16. Impact of distracting activities and drivers' cognitive failures on driving performance

    NARCIS (Netherlands)

    Farah, H.; Zatmeh, S.; Toledo, T.

    2015-01-01

    The rapid increase in the availability of smart phones and other infotainment devices, and their widespread use while driving, contributes significantly to car crash rates. This is since the human brain has limited capacity and cannot perform two tasks at the same time, but rather switches from one

  17. LC-filter Resonance Cancellation with DPWM Inverters in Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Vadstrup, Casper; Wang, Xiongfei; Blaabjerg, Frede

    2015-01-01

    Discontinuous PWM methods cannot easily be used in LC-filtered inverters for adjustable speed drives, as it causes resonances in the filter. This paper present a new method to cancel the resonance and compares this method to previously proposed methods. Wide band gap devices are entering the market...

  18. Secretory activity and endocrine regulation of male accessory glands in the blood-sucking bug Panstrongylus megistus (Hemiptera: Reduviidae

    Directory of Open Access Journals (Sweden)

    Lêda Regis

    1987-01-01

    Full Text Available The epithelial cells of Panstrongylus megistus male accessory glands (MAG present ultrastructural characteristics of a secretory cell. Their secretory products are accumulated in the lumen of the four MAG lobes. During the first 8 days of adult life a strong secretion activity occurs, accumulating enough material to produce the first spermatophore. Cerebral neurosecretions as well as juvenile hormone are both involved in MAG secretory activity regulation. Juvenile hormone seems to be the responsible for the stimulation of most protein synthesis in male accessory glands. Cerebral neurosecretion seems to be necessary to stimulate juvenile hormone production and release by the corpus allatum. Furthermore, neurosecretion is required for some polypeptides synthesis by MAG. Although topic application of precocene II to adult males does not reproduce the same effects on MAG as does allatectomy, this compound causes strong reduction on male reproductive capacity.

  19. Os cuboideum secundarium: A rare accessory ossicle with the potential to mimic a mass on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kauffmann, Gregory; Stacy, G.S.

    2014-01-01

    Accessory ossicles are common incidental findings on radiographs of the ankle and foot. While typically asymptomatic and of no clinical significance, they are sometimes associated with local pain or even mistaken for pathological conditions such as fractures. Given the potential for misinterpretation, it is important to understand their typical locations and appearances. This case highlights an exceptionally rare accessory ossicle called the os cuboideum secundarium, located adjacent to the cuboid and calcaneus. Interestingly, this case demonstrates the potential for this rare ossicle to mimic a mass on magnetic resonance imaging (MRI). Furthermore, despite the significant improvements in the understanding of musculoskeletal pathology afforded by advancements in cross-sectional imaging techniques, this case is a reminder of certain pitfalls that remain. Lastly, it highlights the importance of radiographs as an initial diagnostic study in evaluating foot pain. (orig.)

  20. Electromechanical motion devices

    CERN Document Server

    Krause, Paul C; Pekarek, Steven D

    2012-01-01

    This text provides a basic treatment of modern electric machine analysis that gives readers the necessary background for comprehending the traditional applications and operating characteristics of electric machines-as well as their emerging applications in modern power systems and electric drives, such as those used in hybrid and electric vehicles. Through the appropriate use of reference frame theory, Electromagnetic Motion Devices, Second Edition introduces readers to field-oriented control of induction machines, constant-torque, and constant-power control of dc, permanent-magnet ac

  1. Reaction and separation opportunities with microfluidic devices

    NARCIS (Netherlands)

    Kolfschoten, R.C.

    2011-01-01

    Microfluidic devices make precisely controlled processing of substances possible on a microliter level. The advantage is that, due to the small sizes, the driving forces for mass and heat transfer are high. The surface to volume ratios are also high, which can benefit many surface oriented

  2. Microcontroller based Stator Winding Resistance Determination of Induction Motor Drive on Temperature Variations

    OpenAIRE

    Siraj Ahmed T; Sukhdeo Sao; K.S.R Anjaneyulu

    2014-01-01

    In this paper an experiment has been conducted to determine the online stator winding resistance of an induction motor, in industries as well as domestic purpose induction motors is largely utilized, as it has both applications of variable and constant torque operation nature. The major requirement of an electric drive system is its independent control of torque and speed; this is achieved in DC motor Drive but has more disadvantages. With the help of fast acting switching devices it is possi...

  3. Mechatronic Device for Locomotor Training

    Directory of Open Access Journals (Sweden)

    Duda Sławomir

    2016-12-01

    Full Text Available This paper presents a novel mechatronic device to support a gait reeducation process. The conceptual works were done by the interdisciplinary design team. This collaboration allowed to perform a device that would connect the current findings in the fields of biomechanics and mechatronics. In the first part of the article shown a construction of the device which is based on the structure of an overhead travelling crane. The rest of the article contains the issues related to machine control system. In the prototype, the control of drive system is conducted by means of two RT-DAC4/PCI real time cards connected with a signal conditioning interface. Authors present the developed control algorithms and optimization process of the controller settings values. The summary contains a comparison of some numerical simulation results and experimental data from the sensors mounted on the device. The measurement data were obtained during the gait of a healthy person.

  4. State laws restricting driver use of mobile communications devices distracted-driving provisions, 1992-2010.

    Science.gov (United States)

    Ibrahim, Jennifer K; Anderson, Evan D; Burris, Scott C; Wagenaar, Alexander C

    2011-06-01

    State laws limiting the use of mobile communications devices (MCDs) by drivers are being enacted at an accelerating pace. Public health law research is needed to test various legislative models and guide future legal innovation. To define the current state of the law, facilitate new multi-state evaluations, and demonstrate the utility of systematic, scientific legal research methods to improve public health services research. Westlaw and Lexis-Nexis were used to create a 50-state, open-source data set of laws restricting the use of any form of MCD while operating a motor vehicle that were in effect between January 1, 1992, and November 1, 2010. Using an iterative process, the search protocol included the following terms: cellphone, cell phone, cellular phone, wireless telephone, mobile telephone, text, hands-free, cell! and text! The text and citations of each law were collected and coded across 22 variables, and a protocol and code book were developed to facilitate future public use of the data set. Thirty-nine states and the District of Columbia have at least one form of restriction on the use of MCDs in effect. The laws vary in the types of communication activities and categories of driver regulated, as well as enforcement mechanisms and punishments. No state completely bans use of MCDs by all drivers. State distracted-driving policy is diverging from evidence on the risks of MCD use by drivers. An updatable data set of laws is now available to researchers conducting multistate evaluations of the impact of laws regulating MCDs by drivers. If this data set is shown to be useful for this public health problem, similar rigorously developed and regularly updated data sets might be developed for other public health issues that are subject to legislative interventions. Copyright © 2011 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Digital 3D reconstruction of two parahissian accessory bundles in a case of Wolff-Parkinson White syndrome

    NARCIS (Netherlands)

    Steffen, C.; Schaepman, M.E.; Hardmeier, T.; Schweitzer, W.

    2004-01-01

    Three-dimensional reconstruction of digitized histological serial sections of the cardiac conduction system yielded two accessory pathways in a case of a 24-day-old male infant who died after a short period of illness with ECG findings of Wolff-Parkinson-White syndrome. In infants, the differential

  6. Dementia & Driving

    Science.gov (United States)

    ... have to give up driving. Many people associate driving with self-reliance and freedom; the loss of driving privileges ... familiar roads and avoid long distances. Avoid heavy traffic and heavily traveled roads. Avoid driving at night and in bad weather. Reduce the ...

  7. A non-invasive cyberrisk in cooperative driving

    OpenAIRE

    Bapp, F.; Becker, J.; Beyerer, Jürgen; Doll, J.; Filsinger, Max; Frese, Christian; Hubschneider, C.; Lauber, A.; Müller-Quade, J.; Pauli, M.; Roschani, Masoud; Salscheider, O.; Rosenhahn, B.; Ruf, Miriam; Stiller, C.

    2017-01-01

    This paper presents a hacking risk arising in fully automated cooperative driving. As opposed to common cyber risk scenarios, this scenario does not require internal access to an automated car at all, and is therefore largely independent of current on-board malware protection. A hacker uses a wireless mobile device, for example a hacked smartphone, to send vehicle to- vehicle (V2V) signals from a human-driven car, masquerading it as a fully-automated, cooperating vehicle. It deliberately enga...

  8. Distracted driving behaviors of adults while children are in the car.

    Science.gov (United States)

    Roney, Linda; Violano, Pina; Klaus, Greg; Lofthouse, Rebecca; Dziura, James

    2013-10-01

    Cell phone use while driving is common and can result in driver distraction. However, data on the frequency of this behavior with other occupants in the vehicle are lacking. This study investigates whether adult drivers engage in cell phone use with passengers in the car and determines whether the frequency of these behaviors was modified if the passenger was a child. Subjects (N = 539) who have driven children during the previous 30 days were recruited to complete a survey regarding their cell phone usage while driving. The inclusion criteria of participants were as follows: 18 years or older with a valid driver's license, owns/uses a cell phone, drives with children, and reads English. Results were reported on a 4-point Likert scale (always, often, rarely, and never). Eighty percent of respondents reported cell phone use in some way while driving with children. As compared with similar behaviors when driving alone or with adult passengers, the odds of reporting "always" compared with "often, rarely, or never" of holding a cell phone in hand was 0.66 when driving with children. No significant differences were noted for the following variables: use of a blue tooth device or use of a cell phone to speak or text when parked. Cell phone use while driving is common. Distracted driving behaviors, although less frequent, persist when children are passengers in the vehicle. Further research into the effect of cell phone-related distracted driving behaviors of adults with child passengers is needed to address this public health concern.

  9. [Digitalization study of sonotubometry device].

    Science.gov (United States)

    Li, Yang; Chen, Shu; Xu, Li; Nong, Dongxiao; Tang, Anzhou; Zhang, Zhiwei

    2014-06-01

    Sonotubometry is wildly used in developed countries, offers a easy, versatile and objective way to assess the function of Eustachian tube. The objectives of this study are to develop a low-cost digitalized device. The digitalized sonotubometry device was made of a personal computer with sound input and output accessories. The PC sound card, connected to a signal amplifier, exported probe band noise, while feedback sound was collected by a microphone. All 36 volunteers (72 ears) were involved in the sonotubometry test with JK-04A and CHN-08, in the conditions of dry-swallowing and wet-swallowing. The data were statistically analyzed using SPSS 13.0. The basic electroacoustic performance of the CHN-08 was acceptable. CHN-08 (7 kHz) detection and JK-04A consistency of kappa index was 0.472; CHN-08 (8 kHz) and JK-04A consistency of kappa index was 0.487; CHN-08 (7 kHz) and CHN-08 (8 kHz) consistency of kappa index was 0.688.Under the JK-04A, CHN-08 (7 kHz) and CHN-08 (8 kHz) three setups, Eustachian tube opening frequency was significantly lower for wet-swallowing than dry-swallowing, P digitalized sonotubometry is successfully developed. Its electroacoustic performance proved acceptable by authority assessments. The detection rate of CHN-08 is in accordance with that of JK-04A moderately. The study revealed that Eustachian tube is opened more easily by dry-swallowing than by wet-swallowing.

  10. 30 CFR 18.48 - Circuit-interrupting devices.

    Science.gov (United States)

    2010-07-01

    ... energized. (f) Belt conveyors shall be equipped with control switches to automatically stop the driving motor in the event the belt is stopped, or abnormally slowed down. Note: Short transfer-type conveyors... Design Requirements § 18.48 Circuit-interrupting devices. (a) Each machine shall be equipped with a...

  11. Prevalence of and attitudes about distracted driving in college students.

    Science.gov (United States)

    Hill, Linda; Rybar, Jill; Styer, Tara; Fram, Ethan; Merchant, Gina; Eastman, Amelia

    2015-01-01

    To identify current distracted driving (DD) behaviors among college students, primarily those involving cell phone use, and elucidate the opinions of the students on the most effective deterrent or intervention for reducing cell phone use. Students enrolled at 12 colleges and universities were recruited to participate in an online, anonymous survey. Recruitment was done via school-based list-serves and posters. School sizes ranged from 476 to over 30,000. The validated survey included 38 questions; 17 were specifically related to distracted driving. Four thousand nine hundred sixty-four participants completed the surveys; the average age was 21.8, 66% were female, 82.7% were undergraduates, and 47% were white/non-Hispanic. Additionally, 4,517 (91%) reported phoning and/or texting while driving; 4,467 (90%) of drivers said they talk on the phone while driving; 1,241 (25%) reported using a hands-free device "most of the time"; 4,467 (90%) of drivers reported texting while driving; 2,488 (50%) reported sending texts while driving on the freeway; 2,978 (60%) while in stop-and-go traffic or on city streets; and 4,319 (87%) at traffic lights. Those who drove more often were more likely to drive distracted. When asked about their capability to drive distracted, 46% said they were capable or very capable of talking on a cell phone and driving, but they felt that only 8.5% of other drivers were capable. In a multivariate model, 9 predictors explained 44% of the variance in DD, which was statistically significant, F (17, 4945) = 224.31; P driving frequency) were self-efficacy (i.e., confidence) in driving while multitasking (β = 0.37), perception of safety of multitasking while driving (β = 0.19), social norms (i.e., observing others multitasking while driving; β = 0.29), and having a history of crashing due to multitasking while driving (β = 0.11). Distracted driving is a highly prevalent behavior among college students who have higher confidence in their own driving

  12. Accuracy of algorithms to predict accessory pathway location in children with Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Wren, Christopher; Vogel, Melanie; Lord, Stephen; Abrams, Dominic; Bourke, John; Rees, Philip; Rosenthal, Eric

    2012-02-01

    The aim of this study was to examine the accuracy in predicting pathway location in children with Wolff-Parkinson-White syndrome for each of seven published algorithms. ECGs from 100 consecutive children with Wolff-Parkinson-White syndrome undergoing electrophysiological study were analysed by six investigators using seven published algorithms, six of which had been developed in adult patients. Accuracy and concordance of predictions were adjusted for the number of pathway locations. Accessory pathways were left-sided in 49, septal in 20 and right-sided in 31 children. Overall accuracy of prediction was 30-49% for the exact location and 61-68% including adjacent locations. Concordance between investigators varied between 41% and 86%. No algorithm was better at predicting septal pathways (accuracy 5-35%, improving to 40-78% including adjacent locations), but one was significantly worse. Predictive accuracy was 24-53% for the exact location of right-sided pathways (50-71% including adjacent locations) and 32-55% for the exact location of left-sided pathways (58-73% including adjacent locations). All algorithms were less accurate in our hands than in other authors' own assessment. None performed well in identifying midseptal or right anteroseptal accessory pathway locations.

  13. Posterior Coronary Vein as the Substrate for an Epicardial Accessory Pathway

    Directory of Open Access Journals (Sweden)

    Laura Cipoletta, MD

    2013-07-01

    Full Text Available Catheter ablation of Wolff-Parkinson-White syndrome is associated with up to 5% of failure. Coronary sinus (CS abnormalities or connections between CS myocardial coat and left ventricular epicardium are associated with posteroseptal and left posterior accessory pathways (AP. A 41-year-old patient with WPW syndrome was referred to our hospital after three unsuccessful ablations. The 12-lead ECG suggested a left posteroseptal AP. CT imaging and electro-anatomic mapping showed a relationship between AP electrical course and CS posterior branch. This finding supports the hypothesis CSAPs lie in the myocardial coat around CS and represent an extensive connection between atrial and ventricular epicardial surface.

  14. The role of accessory proteins in the replication of feline infectious peritonitis virus in peripheral blood monocytes.

    Science.gov (United States)

    Dedeurwaerder, Annelike; Desmarets, Lowiese M; Olyslaegers, Dominique A J; Vermeulen, Ben L; Dewerchin, Hannah L; Nauwynck, Hans J

    2013-03-23

    The ability to productively infect monocytes/macrophages is the most important difference between the low virulent feline enteric coronavirus (FECV) and the lethal feline infectious peritonitis virus (FIPV). In vitro, the replication of FECV in peripheral blood monocytes always drops after 12h post inoculation, while FIPV sustains its replication in the monocytes from 45% of the cats. The accessory proteins of feline coronaviruses have been speculated to play a prominent role in virulence as deletions were found to be associated with attenuated viruses. Still, no functions have been ascribed to them. In order to investigate if the accessory proteins of FIPV are important for sustaining its replication in monocytes, replication kinetics were determined for FIPV 79-1146 and its deletion mutants, lacking either accessory protein open reading frame 3abc (FIPV-Δ3), 7ab (FIPV-Δ7) or both (FIPV-Δ3Δ7). Results showed that the deletion mutants FIPV-Δ7 and FIPV-Δ3Δ7 could not maintain their replication, which was in sharp contrast to wt-FIPV. FIPV-Δ3 could still sustain its replication, but the percentage of infected monocytes was always lower compared to wt-FIPV. In conclusion, this study showed that ORF7 is crucial for FIPV replication in monocytes/macrophages, giving an explanation for its importance in vivo, its role in the development of FIP and its conservation in field strains. The effect of an ORF3 deletion was less pronounced, indicating only a supportive role of ORF3 encoded proteins during the infection of the in vivo target cell by FIPVs. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Mechatronics in electric machinery and drives; 2. ed.; Mechatronik in elektrischen Maschinen und Antrieben

    Energy Technology Data Exchange (ETDEWEB)

    Gutt, H.J. [comp.

    1995-12-31

    Mechatronics is a novel field of work (characterized by closely interlocked and interdisciplinary collaboration among university faculties, institutes, and industrial enterprise) in which activities so far have been harvesting unexpectedly successful results in terms of synergetic effects marking a signpost to the future in many fields of application. Electric machines and drives play a major role in this process as the link between the field of electrical engineering and mechanics on the one hand, and technical computer science on the other. In driving systems, many accessory components such as electronic components or sensors can be saved by skilful and purposeful selection and combination, and design, of electric driving mechanisms and actuators. One contribution in this report presents an interesting case showing that employment of an unconventional synchronous motor can replace all electronic instrumentation hitherto used for run up and monitoring. Another contribution shows that the electric machines can be used for twofold tasks, also serving as essential information sources in combination with neural networks, an emerging development that may have a brilliant future. (orig./GL) [Deutsch] Die Mechatronik (d.h. das engverzahnte interdisziplinaere Zusammenwirken mehrerer Fakultaeten, Institute und interessierter Industrieunternehmen) zeigt zukunftsweisend auf vielfaeltigen Einsatzgebieten unerwartete synergetische Erfolge. Eine wesentliche Schluesselrolle kommt hierbei den elektrischen Maschinen und Antrieben als Bindeglied der Elektrotechnik zwischen der Mechanik einerseits und der Informatik andererseits zu. In kompletten Antriebssystemen allein durch die geschickte Wahl und Gestaltung der elektrischen Antriebsmaschinen und Aktoren zugleich viele, bisher additiv verwendete Komponenten der Sensorik und Eletronik eingespart werden koennen. Ausserdem wird ein Extremfall der Verbilligung dargestellt, in dem unter Verwendung eines unkonventionellen Synchronmotors

  16. DESIGN AND STUDY OF DRIVE SWIVEL JOINTS FOR HYDRAULIC MANIPULATION SYSTEMS OF MOBILE TRANSPORT-TECHNOLOGICAL MACHINES

    Directory of Open Access Journals (Sweden)

    Lagerev A.V.

    2018-03-01

    Full Text Available The paper presents the design and principle of operation of a new type of articulated connection of adjacent links of manipulation systems of mobile transport and technological machines – the drive swivel joints to provide a rotary rela-tive movement of the links. Their design allows to combine the function of ensuring the continuity of the kinematic chain and the function of providing rotary movement adjacent units and without the use of additional external devices. The design of the device is protected by a patent of the Russian Federation. Drive swivel joints are an alternative to tra-ditional designs of articulated joints with external power hydraulic drives. Developed a mathematical optimization model. The model is based on the minimization of the mass of the drive swivel joints when you complete the necessary design, installation, operating and strength constraints. Based on this mathematical model the proposed method of com-puter-aided design of the drive swivel joints, which is implemented in a computer program. A study was conducted of the influence of the main technical characteristics and magnitude of the operational load at the optimal weight and the optimal constructive dimensions of the drive swivel joints. It is shown that at equal freight-altitude characteristics of mobile crane-manipulator the drive swivel joint allows you to exclude a number of operational shortcomings of the tra-ditional swivel: 1 development over time of the additional dynamic load of metal due to the increased clearances in connection; 2 lowering the volume of the working area of the crane due to the presence of external power of hydraulic drives; 3 the appearance of cracks due to fatigue failure of the elements of the attachment point of the hydraulic drives to the links of manipulation system. It is possible that the transfer of the hydraulic system for lower operating pressure, which increases the efficiency of the crane and the efficiency of the

  17. Presence of a long accessory flexor tendon of the toes in surgical treatment for tendinopathy of the insertion of the calcaneal tendon: case report

    Directory of Open Access Journals (Sweden)

    Nelson Pelozo Gomes Júnior

    2016-02-01

    Full Text Available ABSTRACT The presence of accessory tendons in the foot and ankle needs to be recognized, given that depending on their location, they may cause disorders relating either to pain processes or to handling of the surgical findings. We describe the presence of an accessory flexor tendon of the toes, seen in surgical exposure for transferring the long flexor tendon of the hallux to the calcaneus, due to the presence of a disorder of tendinopathy of the insertion of the calcaneal tendon in association with Haglund's syndrome.

  18. Electric drives

    CERN Document Server

    Boldea, Ion

    2005-01-01

    ENERGY CONVERSION IN ELECTRIC DRIVESElectric Drives: A DefinitionApplication Range of Electric DrivesEnergy Savings Pay Off RapidlyGlobal Energy Savings Through PEC DrivesMotor/Mechanical Load MatchMotion/Time Profile MatchLoad Dynamics and StabilityMultiquadrant OperationPerformance IndexesProblemsELECTRIC MOTORS FOR DRIVESElectric Drives: A Typical ConfigurationElectric Motors for DrivesDC Brush MotorsConventional AC MotorsPower Electronic Converter Dependent MotorsEnergy Conversion in Electric Motors/GeneratorsPOWER ELECTRONIC CONVERTERS (PECs) FOR DRIVESPower Electronic Switches (PESs)The

  19. Gastrointestinal bleeding: an accessory spleen causing a false-positive Tc-99m-sulfur colloid study

    International Nuclear Information System (INIS)

    Heyman, S.; Sunaryo, F.P.; Ziegler, M.M.

    1982-01-01

    A Tc-99m-sulfur colloid abdominal scan was performed on a 12-year-old girl to localize the site of gastrointestinal bleeding. The study was normal. When bleeding recurred two weeks later, a repeat study revealed a focal abnormality in the upper abdomen. This was thought to be compatible with a small bleed. However, at surgery an accessory spleen was found, accounting for the abnormal scan

  20. Generic Dynamic Environment Perception Using Smart Mobile Devices.

    Science.gov (United States)

    Danescu, Radu; Itu, Razvan; Petrovai, Andra

    2016-10-17

    The driving environment is complex and dynamic, and the attention of the driver is continuously challenged, therefore computer based assistance achieved by processing image and sensor data may increase traffic safety. While active sensors and stereovision have the advantage of obtaining 3D data directly, monocular vision is easy to set up, and can benefit from the increasing computational power of smart mobile devices, and from the fact that almost all of them come with an embedded camera. Several driving assistance application are available for mobile devices, but they are mostly targeted for simple scenarios and a limited range of obstacle shapes and poses. This paper presents a technique for generic, shape independent real-time obstacle detection for mobile devices, based on a dynamic, free form 3D representation of the environment: the particle based occupancy grid. Images acquired in real time from the smart mobile device's camera are processed by removing the perspective effect and segmenting the resulted bird-eye view image to identify candidate obstacle areas, which are then used to update the occupancy grid. The occupancy grid tracked cells are grouped into obstacles depicted as cuboids having position, size, orientation and speed. The easy to set up system is able to reliably detect most obstacles in urban traffic, and its measurement accuracy is comparable to a stereovision system.

  1. Biventricular assist using a portable driver in combination with implanted devices: preliminary experience.

    Science.gov (United States)

    von Segesser, L K; Tkebuchava, T; Leskosek, B; Marty, B; Pei, Y C; Turina, M

    1997-01-01

    Left ventricular assist systems with portable drive units are increasingly used in the clinical setting. However, such systems usually are not suitable for right ventricular support, and therefore, in the case of biventricular heart failure, they must be combined with other support devices that require additional drive consoles. As a result, most of the benefits of the wearable drive units (early mobilization and outpatient care) are lost. This present study was performed to evaluate biventricular support with implanted assist devices and a portable DC/battery-powered driver (Thoratec TLC-II). Electronic control by nonvolatile RAM accessible via RS232 interface, internal backup emergency battery, and optional manual activation are additional features of this 6 kg biventricular drive unit. In 3 bovine experiments (body weight 70 +/- 5 kg) partial cardiopulmonary bypass (CPB) was established, and two ventricular assist devices were implanted into a preperitoneal pocket on each side after connection to the right atrium and the pulmonary artery and to the left atrium and aorta, respectively. After weaning the patient from CPB, activated coagulation time (ACT) was kept at greater than 180 s, and biventricular support with the portable driver was activated. After 10 min, mean device flow stabilized at 3.5 +/- 0 L/min and remained at that level throughout the ensuing 6 h (3.5 +/- 0.3 L/min; NS). The heart rate moved from 130 +/- 13 beats per minute (bpm) at the end of CPB to 116 +/- 13 bpm after 10 min of assist (p < 0.05). Right atrial pressure moved from 11 +/- 2 mm Hg at the end of CPB to 13 +/- 3 mm Hg after 10 min of assist (not significant [NS]). Mean pulmonary artery pressure was 18 +/- mm Hg at the end of CPB and 17 +/- 5 mm Hg after 10 min of assist (NS). Left atrial pressure was 10 +/- 1 mm Hg at the end of CPB and 13 +/- 3 mm Hg after 10 min of assist (NS). Mean aortic pressure was 73 +/- 11 mm Hg at the end of CPB and 77 +/- 3 mm Hg after 10 min of assist (NS

  2. [Comparison of ablation of left-sided accessory pathway by atrial septal and retrograde arterial approach].

    Science.gov (United States)

    Zhu, J G; Bao, Z Y; Gu, X

    2017-03-07

    Objective: To compare the advantages and disadvantages of radiofrequency ablation of left-sided accessory pathways by via atrial septal approach with retrograde through aortic approach. Methods: A total of 184 patients of left-side accessory pathways were treated in Taizhou People's Hospital and the Subei People's Hospital from March 2012 to August 2015.A total of 103 cases were treated by aortic retrograde approach as through arterial group, 81 cases were treated by punctured atrial septal to left atrial for mapping and ablation as through atrial septal group.Comparison of ablation procedure time, total and pathways of different parts(subgroup) at instant success and relapse rates, safety (serious complications), and statistics other complications in operation and postoperative. Results: Through arterial group and through atrial septal group were no significant difference ( P >0.05) in the ablation procedure time((25±18 ) vs (22±15)min ), instant success(98.1% vs 97.5%) and relapse rates(1.0% vs 1.2%), security(1 vs 0 case). There was no statistical difference in septal part subgroups (all P >0.05) in the ablation procedure time((22±18)vs (25±19)min), instant success(91.7% vs 89.9 %) and relapse rates(0 vs 11.1%); posterior wall subgroup had no statistical difference in the ablation procedure time((18±15)vs (16±12)min), instant success(100% vs 100 %) and relapse rates(0 vs 0)(all P >0.05); side wall subgroup had no statistical difference in the ablation procedure time((29±20)vs (21±18) min), instant success (98.3% vs 98.1%)and relapse rates(1.7% vs 0%)(all P >0.05). Conclusion: Ablation of left-sided accessory pathways by transseptal approach and transaortic approach has no statistical difference in the procedure time, instant success and relapse rates, security.In a particular case, there is a certain complementarity between the two methods.

  3. Impact of infection on the secretory capacity of the male accessory glands

    Directory of Open Access Journals (Sweden)

    M. Marconi

    2009-06-01

    Full Text Available INTRODUCTION: Studies that compare the impact of different infectious entities of the male reproductive tract (MRT on the male accessory gland function are controversial. MATERIAL AND METHODS: Semen analyses of 71 patients with proven infections of the MRT were compared with the results of 40 healthy non-infected volunteers. Patients were divided into 3 groups according to their diagnosis: chronic prostatitis NIH type II (n = 38, chronic epididymitis (n = 12, and chronic urethritis (n = 21. RESULTS: The bacteriological analysis revealed 9 different types of microorganisms, considered to be the etiological agents, isolated in different secretions, including: urine, expressed prostatic secretions, semen and urethral smears: E. Coli (n = 20, Klebsiella (n = 2, Proteus spp. (n = 1, Enterococcus (n = 20, Staphylococcus spp. (n = 1, M. tuberculosis (n = 2, N. gonorrhea (n = 8, Chlamydia tr. (n = 16 and, Ureaplasma urealyticum (n = 1. The infection group had significantly (p < 0.05 lower: semen volume, alpha-glucosidase, fructose, and zinc in seminal plasma and, higher pH than the control group. None of these parameters was sufficiently accurate in the ROC analysis to discriminate between infected and non-infected men. CONCLUSION: Proven bacterial infections of the MRT impact negatively on all the accessory gland function parameters evaluated in semen, suggesting impairment of the secretory capacity of the epididymis, seminal vesicles and prostate. These findings were associated with an infectious related significant increase of semen pH. None of the semen parameters evaluated can be suggested as a diagnostic tool for infection.

  4. Management of scientific information with Google Drive.

    Science.gov (United States)

    Kubaszewski, Łukasz; Kaczmarczyk, Jacek; Nowakowski, Andrzej

    2013-09-20

    The amount and diversity of scientific publications requires a modern management system. By "management" we mean the process of gathering interesting information for the purpose of reading and archiving for quick access in future clinical practice and research activity. In the past, such system required physical existence of a library, either institutional or private. Nowadays in an era dominated by electronic information, it is natural to migrate entire systems to a digital form. In the following paper we describe the structure and functions of an individual electronic library system (IELiS) for the management of scientific publications based on the Google Drive service. Architecture of the system. Architecture system consists of a central element and peripheral devices. Central element of the system is virtual Google Drive provided by Google Inc. Physical elements of the system include: tablet with Android operating system and a personal computer, both with internet access. Required software includes a program to view and edit files in PDF format for mobile devices and another to synchronize the files. Functioning of the system. The first step in creating a system is collection of scientific papers in PDF format and their analysis. This step is performed most frequently on a tablet. At this stage, after being read, the papers are cataloged in a system of folders and subfolders, according to individual demands. During this stage, but not exclusively, the PDF files are annotated by the reader. This allows the user to quickly track down interesting information in review or research process. Modification of the document title is performed at this stage, as well. Second element of the system is creation of a mirror database in the Google Drive virtual memory. Modified and cataloged papers are synchronized with Google Drive. At this stage, a fully functional scientific information electronic library becomes available online. The third element of the system is a

  5. Older drivers with cognitive impairment: Perceived changes in driving skills, driving-related discomfort and self-regulation of driving

    DEFF Research Database (Denmark)

    Meng, A.; Siren, A.; Teasdale, Thomas William

    2013-01-01

    The results of a previous study indicate that in general, older drivers who recognise cognitive problems show realistic self-assessment of changes in their driving skills and that driving-related discomfort may function as an indirect monitoring of driving ability, contributing to their safe...... drivers may recognise cognitive problems, they tend not to recognise changes to their driving, which may reflect reluctance to acknowledge the impact of cognitive impairment on their driving. Furthermore, the results suggest that driving-related discomfort plays an important role in the self......-regulation of driving among cognitively impaired older drivers. However, it is less clear what triggers driving-related discomfort among cognitively impaired older drivers indicating that it may be a less reliable aspect of their self-monitoring of driving ability....

  6. Arthroscopic Broström repair with Gould augmentation via an accessory anterolateral port for lateral instability of the ankle.

    Science.gov (United States)

    Matsui, Kentaro; Takao, Masato; Miyamoto, Wataru; Innami, Ken; Matsushita, Takashi

    2014-10-01

    Although several arthroscopic surgical techniques for the treatment of lateral instability of the ankle have been introduced recently, some concern remains over their procedural complexity, complications, and unclear clinical outcomes. We have simplified the arthroscopic technique of Broström repair with Gould augmentation. This technique requires only two small skin incisions for two ports (medial midline and accessory anterolateral ports), without needing a percutaneous procedure or extension of the skin incisions. The anterior talofibular ligament is reattached to its anatomical footprint on the fibula with suture anchor, under arthroscopic view. The inferior extensor retinaculum is directly visualized through the accessory anterolateral port and is attached to the fibula with another suture anchor under arthroscopic view via the anterolateral port. The use of two small ports offers a procedure that is simple to perform and less morbid for patients.

  7. Optimization of Smart Structure for Improving Servo Performance of Hard Disk Drive

    Science.gov (United States)

    Kajiwara, Itsuro; Takahashi, Masafumi; Arisaka, Toshihiro

    Head positioning accuracy of the hard disk drive should be improved to meet today's increasing performance demands. Vibration suppression of the arm in the hard disk drive is very important to enhance the servo bandwidth of the head positioning system. In this study, smart structure technology is introduced into the hard disk drive to suppress the vibration of the head actuator. It has been expected that the smart structure technology will contribute to the development of small and light-weight mechatronics devices with the required performance. First, modeling of the system is conducted with finite element method and modal analysis. Next, the actuator location and the control system are simultaneously optimized using genetic algorithm. Vibration control effect with the proposed vibration control mechanisms has been evaluated by some simulations.

  8. Drive Stands

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrical Systems Laboratory (ESL)houses numerous electrically driven drive stands. A drive stand consists of an electric motor driving a gearbox and a mounting...

  9. Comparing Expert and Novice Driving Behavior in a Driving Simulator

    Directory of Open Access Journals (Sweden)

    Hiran B. Ekanayake

    2014-02-01

    Full Text Available This paper presents a study focused on comparing driving behavior of expert and novice drivers in a mid-range driving simulator with the intention of evaluating the validity of driving simulators for driver training. For the investigation, measurements of performance, psychophysiological measurements, and self-reported user experience under different conditions of driving tracks and driving sessions were analyzed. We calculated correlations between quantitative and qualitative measures to enhance the reliability of the findings. The experiment was conducted involving 14 experienced drivers and 17 novice drivers. The results indicate that driving behaviors of expert and novice drivers differ from each other in several ways but it heavily depends on the characteristics of the task. Moreover, our belief is that the analytical framework proposed in this paper can be used as a tool for selecting appropriate driving tasks as well as for evaluating driving performance in driving simulators.

  10. Artificial intelligence-based condition monitoring for practical electrical drives

    OpenAIRE

    Ashari, Djoni; Pislaru, Crinela; Ball, Andrew; Gu, Fengshou

    2012-01-01

    The main types of existing Condition Monitoring methods (MCSA, GA, IAS) for electrical drives are\\ud described. Then the steps for the design of expert systems are presented: problem identification and analysis, system specification, development tool selection, knowledge based, prototyping and testing. The employment of SOMA (Self-Organizing Migrating Algorithm) used for the optimization of ambient\\ud vibration energy harvesting is analyzed. The power electronics devices are becoming smaller ...

  11. Progress with helicity injection current drive

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Raman, R.; Nelson, B.A.

    2003-01-01

    Coaxial Helicity Injection (CHI) experiments in the NSTX and HIT-II devices are reported. NSTX has produced toroidal currents of 0.4 MA and pulse lengths of up to 0.33 s. These discharges nearly fill the NSTX main chamber, and show the n=1 rotating distortion characteristic of high-performance CHI plasmas. CHI has been used in HIT-II to provide a closed flux startup plasma for inductive drive. The CHI startup method saves transformer volt-seconds and greatly improves reproducibility and reliability of inductively driven discharges, even in the presence of diminishing wall conditions. (author)

  12. The Organic Power Transistor: Roll-to-Roll Manufacture, Thermal Behavior, and Power Handling When Driving Printed Electronics

    DEFF Research Database (Denmark)

    Pastorelli, Francesco; Schmidt, Thomas Mikael; Hösel, Markus

    2016-01-01

    to drive large currents while handling the thermal aspects in operation together with other organic printed electronics technologies such as large area organic photovoltaics (OPV)[2] and large area electrochromic displays (EC).[3] We find especially that an elevated operational temperature is beneficial...... with respect to both transconductance and on/off ratio. We achieve high currents of up to 45mA at a temperature of 80 C with an on/ off ratio of 100 which is sufficient to drive large area organic electronics such as an EC device powered by OPV devices that we also demonstrate. Finally, we observe......We present flexible organic power transistors prepared by fast (20mmin1) roll-to-roll (R2R) flexographic printing[1] of the drain (D) and source (S) electrode structures directly on polyester foil. The devices have top gate architecture and were completed by spin coating or slot-die coating...

  13. Special servicing equipment for reactor pressurized vessel stud hole and stud accessories

    International Nuclear Information System (INIS)

    Li Jianglian

    1999-01-01

    The author briefly introduces the design and manufacture of nuclear island special servicing equipment of Nuclear Power Institute of China. Maintenance process of reactor pressurized vessel (RPV) stud hold and stud accessories the special servicing equipment include RPV flange dummy, closed-circuit television (CCTV) inspection equipment, RPV stud hole expandable comb, RPV stud hole polisher, RPV stud hold thread lubricating equipment, RPV stud hole thread miller and RPV stud hole camera. It is presented how eight kinds of special servicing equipment perform the maintenance process concerning their function, structure, and characteristics, their practical use on site is also introduced

  14. High-resolution mapping and ablation of recurrent left lateral accessory pathway conduction

    Directory of Open Access Journals (Sweden)

    Francesco Solimene, MD

    2017-08-01

    Full Text Available Proper localization of the anatomical target during ablation of the accessory pathways (AP and the ability to detect clear AP potentials on the ablation catheter are crucial for successful AP ablation. We report a case of recurring AP conduction that was finally eliminated using a novel ablation catheter equipped with high-resolution mini-electrodes. Smaller and closer electrodes result in high mapping resolution with less signal averaging and cancellation effects. Owing to improved sensitivity, the new catheter seems effective in detecting fragmented and high frequency signals, thus allowing more effective radiofrequency application and improving ablation success.

  15. 49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.

    Science.gov (United States)

    2010-10-01

    ... Devices, and Electrical Wiring § 393.24 Requirements for head lamps, auxiliary driving lamps and front fog lamps. (a) Headlamps. Every bus, truck and truck tractor shall be equipped with headlamps as required by...

  16. Cognitive problems, self-rated changes in driving skills, driving-related discomfort and self-regulation of driving in old drivers

    DEFF Research Database (Denmark)

    Meng, Annette; Siren, Anu Kristiina

    2012-01-01

    Ageing in general is associated with functional decline that may have an adverse effect on driving. Nevertheless, older drivers have been found to show good judgement and to self-regulate their driving, which may enable them to continue driving safely despite functional decline. The process...... of the self-monitoring of driving ability and the awareness of functional decline, and its association with the self-regulation of driving is, however, not fully understood. The aim of the present study was to examine the perceived changes in driving skills, the discomfort experienced in driving, and the self......-related discomfort is an important factor affecting the self-regulation of driving. Finally, the findings indicate that driving-related discomfort functions as an indirect self-monitoring of driving ability and may contribute to the safe driving performance of Danish older drivers....

  17. PV Array Driven Adjustable Speed Drive for a Lunar Base Heat Pump

    Science.gov (United States)

    Domijan, Alexander, Jr.; Buchh, Tariq Aslam

    1995-01-01

    A study of various aspects of Adjustable Speed Drives (ASD) is presented. A summary of the relative merits of different ASD systems presently in vogue is discussed. The advantages of using microcomputer based ASDs is now widely understood and accepted. Of the three most popular drive systems, namely the Induction Motor Drive, Switched Reluctance Motor Drive and Brushless DC Motor Drive, any one may be chosen. The choice would depend on the nature of the application and its requirements. The suitability of the above mentioned drive systems for a photovoltaic array driven ASD for an aerospace application are discussed. The discussion is based on the experience of the authors, various researchers and industry. In chapter 2 a PV array power supply scheme has been proposed, this scheme will have an enhanced reliability in addition to the other known advantages of the case where a stand alone PV array is feeding the heat pump. In chapter 3 the results of computer simulation of PV array driven induction motor drive system have been included. A discussion on these preliminary simulation results have also been included in this chapter. Chapter 4 includes a brief discussion on various control techniques for three phase induction motors. A discussion on different power devices and their various performance characteristics is given in Chapter 5.

  18. Expression of a male accessory gland peptide of Leptinotarsa decemlineata in insect cells infected with a recombinant baculovirus.

    NARCIS (Netherlands)

    Smid, H.M.; Schooneveld, H.; Deserno, M.L.L.G.; Put, B.; Vlak, J.M.

    1998-01-01

    The male accessory glands (MAGs) of Leptinotarsa decemlineata produce an 8kDa peptide, designated Led-MAGP, that is recognized by monoclonal antibody MAC-18. The site of synthesis, amino acid sequence and the gene encoding this peptide have been documented (). The primary structure is homologous to

  19. Note: Motor-piezoelectricity coupling driven high temperature fatigue device.

    Science.gov (United States)

    Ma, Z C; Du, X J; Zhao, H W; Ma, X X; Jiang, D Y; Liu, Y; Ren, L Q

    2018-01-01

    The design and performance evaluation of a novel high temperature fatigue device simultaneously driven by servo motor and piezoelectric actuator is our focus. The device integrates monotonic and cyclic loading functions with a maximum tensile load of 1800 N, driving frequency of 50 Hz, alternating load of 95 N, and maximum service temperature of 1200 °C. Multimodal fatigue tests with arbitrary combinations of static and dynamic loads are achieved. At temperatures that range from RT to 1100 °C, the tensile and tensile-fatigue coupling mechanical behaviors of UM Co50 alloys are investigated to verify the feasibility of the device.

  20. An open source 3-d printed modular micro-drive system for acute neurophysiology.

    Directory of Open Access Journals (Sweden)

    Shaun R Patel

    Full Text Available Current, commercial, electrode micro-drives that allow independent positioning of multiple electrodes are expensive. Custom designed solutions developed by individual laboratories require fabrication by experienced machinists working in well equipped machine shops and are therefore difficult to disseminate into widespread use. Here, we present an easy to assemble modular micro-drive system for acute primate neurophysiology (PriED that utilizes rapid prototyping (3-d printing and readily available off the shelf-parts. The use of 3-d printed parts drastically reduces the cost of the device, making it available to labs without the resources of sophisticated machine shops. The direct transfer of designs from electronic files to physical parts also gives researchers opportunities to easily modify and implement custom solutions to specific recording needs. We also demonstrate a novel model of data sharing for the scientific community: a publicly available repository of drive designs. Researchers can download the drive part designs from the repository, print, assemble and then use the drives. Importantly, users can upload their modified designs with annotations making them easily available for others to use.