WorldWideScience

Sample records for access catheter placement

  1. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  2. A comparative analysis of radiological and surgical placement of central venous catheters

    International Nuclear Information System (INIS)

    McBride, Kieran D.; Fisher, Ross; Warnock, Neil; Winfield, David A.; Reed, Malcolm W.; Gaines, Peter A.

    1997-01-01

    Purpose. To compare the differences in practice and outcome of all radiologically and surgically placed central venous catheters retrospectively over a 2-year period simultaneously, at a single institution. Methods.A total of 253 Hickman catheters were inserted in 209 patients; 120 were placed radiologically in 102 patients and 133 were placed surgically in 107 patients. The indication was chemotherapy in 76% of radiological and in 47% of surgical cases; the remainder were for total parenteral nutrition and venous access. Results. There were 6 (4.5%) primary surgical failures and a further 17 (13%) surgical cases requiring multiple placement attempts. Pneumothorax occurred once (0.8%) surgically and four times (3.3%) radiologically. There were no radiological primary misplacements but there were five (3.7%) surgical ones. Catheter or central vein thrombosis occurred in four (3.3%) radiological and five (3.7%) surgical cases. The rate of infection per 1000 catheter-days was 1.9 in radiologically placed catheters and 4.0 in surgically placed ones (p<0.001). Average catheter life-span was similar for the two placement methods (100±23 days). Conclusion. Radiological placement is consistently more reliable than surgical placement. There are fewer placement complications and fewer catheter infections overall

  3. Radiologic placement of tunneled central catheters: rates of success and of immediate complications in a large series.

    Science.gov (United States)

    Docktor, B L; Sadler, D J; Gray, R R; Saliken, J C; So, C B

    1999-08-01

    The objective was to examine the success and immediate complication rates in a large series of radiologically placed tunneled central venous catheters. We prospectively recorded the success and immediate complication rates in 880 consecutive radiologically placed tunneled central venous catheters. We also recorded the indication for placement, the success of placement, the number of passes required, and whether a double- or single-wall puncture occurred. Hemodialysis was the most common indication for long-term venous access. Venous access was successful in all patients, and catheter placement was successful in 99.4% of patients, with only five failed placements. All patients in whom placement was initially unsuccessful underwent successful placement the same day. All catheters were placed using real-time sonographic guidance. Most were placed in an internal jugular vein, with 87.4% requiring only a single needle pass. The immediate complication rate was only 4.0%, and no major complications occurred. To our knowledge, this series is the largest for which the immediate complication and success rates for radiologically placed central venous catheters have been reported. Our results suggest that radiologic placement of tunneled central venous catheters is a safe and effective alternative to surgery.

  4. Previous PICC Placement May Be Associated With Catheter-Related Infections in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Butler, Philip J.; Sood, Shreya; Mojibian, Hamid; Tal, Michael G.

    2011-01-01

    Background: Catheter-related infections (CRIs) are a significant source of morbidity and mortality in hemodialysis patients. The identification of novel, modifiable risk factors for CRIs may lead to improved outcomes in this population. Peripherally inserted central catheters (PICCs) have been hypothesized to compromise vascular access due to vascular damage and venous thrombosis, whereas venous thrombosis has been linked to the development of CRIs. Here we examine the association between PICC placement and CRIs. Methods: A retrospective review was performed of all chronic hemodialysis catheter placements and exchanges performed at a large university hospital from September 2003 to September 2008. History of PICC line use was determined by examining hospital radiologic records from December 1993 to September 2008. Catheter-related complications were assessed and correlated with PICC line history. Results: One hundred eighty-five patients with 713 chronic tunneled hemodialysis catheter placements were identified. Thirty-eight of those patients (20.5%) had a history of PICC placement; these patients were more likely to have CRIs (odds ratio = 2.46, 95% confidence interval = 1.71–3.53, p < .001) compared with patients without a history of PICC placement. There was no difference between the two groups in age or number of catheters placed. Conclusion: Previous PICC placement may be associated with catheter-related infections in hemodialysis patients.

  5. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  6. Percutaneous placement of peritoneal port-catheter in oncologic patients

    International Nuclear Information System (INIS)

    Orsi, Franco; Vigna, Paolo Della; Bonomo, Guido; Penco, Silvia; Lovati, Elena; Bellomi, Massimo

    2004-01-01

    The aim of this paper is to describe the technique of percutaneous ultrasound (US)-guided placement of a peritoneal port-catheter in an interventional radiological setting. Nineteen patients with peritoneal carcinomatosis were selected for intraperitoneal port-catheter placement in order to perform intracavitary receptor-immuno- or radio-immunotherapy with Ytrium-90. All the procedures were performed percutaneously under US and fluoro guidance; the insertion site for catheters was chosen according to abdominal conditions and US findings: all devices were implanted at the lower abdominal quadrants. All patients were followed up with CT and US according to the therapy protocol. The procedure was successfully completed in 15/19 patients, in 4 being contraindicated by peritoneal adhesions. No procedure-related complications and device occlusions during therapy were observed; one catheter displaced 7 months later the placement. In our experience, this procedure was feasible, reliable and easy to perform, allowing the correct administration of the planned intracavitary therapy. Peritoneal adhesions are the main limitation of peritoneal port placement. (orig.)

  7. The blind pushing technique for peripherally inserted central catheter placement through brachial vein puncture.

    Science.gov (United States)

    Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol

    2018-03-01

    The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (pushing technique and primary brachial vein access is technically feasible and may represent an alternative to the conventional PICC placement technique, having low incidences of

  8. Central venous catheter placement by an interventional radiology unit: an australian experience

    International Nuclear Information System (INIS)

    Lee, M. K. S.; Mossop, P. J.; Vrazas, J. I.

    2007-01-01

    The aim of this retrospective study was to analyse the outcomes of central venous catheter (CVC) placement carried out by an interventional radiology unit. A review of our hospital records identified 331 consecutive patients who underwent insertion of a tunnelled or non-tunnelled CVC between January 2000 and December 2004. Key outcome measures included the technical success rate of CVC insertion and the percentage of immediate ( 30 days) complications. A total of 462 CVCs were placed under radiological guidance, with an overall success rate of 98.9%. Immediate complications included one pneumothorax, which was diagnosed 7 days after subclavian CVC insertion, and eight episodes of significant haematoma or bleeding within 24 h of CVC insertion. No cases were complicated by arterial puncture or air embolus. Catheter-related sepsis occurred in 2% of non-tunnelled CVC and 8.9% of tunnelled CVC. The overall incidence of catheter-related sepsis was 0.17 per 100 catheter days. As the demand for chemotherapy and haemodialysis grows with our ageing population, interventional radiology suites are well placed to provide a safe and reliable service for the placement of central venous access devices

  9. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    Science.gov (United States)

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  10. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  11. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-01-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term

  12. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    International Nuclear Information System (INIS)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan

    2004-01-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications

  13. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan [Asan Medical Center, Seoul (Korea, Republic of)

    2004-04-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications.

  14. Catheter placement via the occipital artery to achieve superselective intra-arterial chemotherapy for oral cancer

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Mitsudo, Kenji; Fukui, Takafumi

    2008-01-01

    Superselective intra-arterial chemotherapy via the superficial temporal artery (STA) has become useful for oral cancer. However, this method can not be performed if catheter placement via the STA is impossible. Therefore, we report a surgical method for catheter placement via the occipital artery (OA) to achieve retrograde superselective intra-arterial chemotherapy. Preoperatively, three-dimensional computed tomography angiography was performed to identify the course of the external carotid artery and the relationship between OA and the target artery. Ten patients with oral cancer underwent catheter placement via the OA with Doppler ultrasound and Harmonic Scalpel under local anesthesia. Catheter placement via the OA was superselectively successful in all the patients. The mean exposure time of OA and mean operating time were 17.5 min and 70.5 min, respectively. Catheter placement via the OA is useful when catheter placement via the STA is impossible. Three-dimensional vascular mapping and the use of Doppler ultrasound and Harmonic Scalpel can shorten the surgical time. (author)

  15. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  16. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  17. Interventional radiologic placement of tunneled central venous catheters : results and complications in 557 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Kyo; Do, Young Soo; Paik, Chul H. [Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)] (and others)

    1999-05-01

    To evaluate prospectively the results of interventional radiologic placement of tunneled central venous catheters, and subsequent complications. Between April 1997 and April 1998, a total of 557 tunneled central venous catheters were percutaneously placed in 517 consecutive patients in an interventional radiology suite. The indications were chemotherapy in 533 cases, total parenteral nutrition in 23 and transfusion in one. Complications were evaluated prospectively by means of a chart review, chest radiography, central vein angiography and blood/catheter culture. The technical success rate for tunneled central venous catheter placement was 100% (557/557 cases). The duration of catheter placement ranged from 4 to 356 (mean, 112{+-}4.6) days; Hickman catheters were removed in 252 cases during follow-up. Early complications included 3 cases of pneumothorax(0.5%), 4 cases of local bleeding/hematoma(0.7%), 2 cases of primary malposition(0.4%), and 1 case of catheter leakage(0.2%). Late complications included 42 cases of catheter-related infection(7.5%), 40 cases of venous thrombosis (7.2%), 18 cases of migration (3.2%), 5 cases of catheter / pericatheter of occlusion(0.8%), and 1 case of pseudoaneurysm(0.2%). The infection rate and thrombosis rate per 1000 days were 1.57 and 1.50, respectively. The technical success rate of interventional radiologic placement of tunneled central venous catheters was high. In comparison to conventional surgical placement, it is a more reliable method and leads to fewer complications.

  18. Ultrasound-guided Placement of a Foley Catheter Using a Hydrophilic Guide Wire

    Directory of Open Access Journals (Sweden)

    Mark Huber

    2018-03-01

    Full Text Available Acute urinary retention is a common problem in the emergency department. Patients can present in significant distress, necessitating the placement of a urinary catheter. Foley catheter placement can be difficult to accomplish depending on the etiology of the retention and the degree of the obstruction. In the case presented here, we used ultrasound guidance, a guidewire, and a Foley catheter to successfully relieve a patient’s urinary retention after multiple failed attempts.

  19. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won

    1996-01-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications

  20. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1996-10-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications.

  1. Percutaneous Placement of Central Venous Catheters: Comparing the Anatomical Landmark Method with the Radiologically Guided Technique for Central Venous Catheterization Through the Internal Jugular Vein in Emergent Hemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Koroglu, M.; Demir, M.; Koroglu, B.K.; Sezer, M.T.; Akhan, O.; Yildiz, H.; Yavuz, L.; Baykal, B.; Oyar, O. [Suleyman Demirel Univ., Isparta (Turkey). Depts. of Radiology, Internal Medicine and Anesthesiology

    2006-02-15

    Purpose: To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. Material and Methods: The study was performed prospectively in a randomized manner. The success and immediate complication rates of radiologically guided placement of central venous access catheters through the internal jugular vein (n = 40) were compared with those of the anatomical landmark method (n 40). The success of placement, the complications, the number of passes required, and whether a single or double-wall puncture occurred were also noted and compared. Results: The groups were comparable in age and sex. The indication for catheter placement was hemodialysis access in all patients. Catheter placement was successful in all patients in group 2 and unsuccessful in 1 (2.5%) patient in group 1. All catheters functioned adequately and immediately after the placement (0% initial failure rate) in group 2, but 3 catheters (7.5% initial failure rate) were non-functional just after placement in group 1. The total number of needle passes, double venous wall puncture, and complication rate were significantly lower in group 2. Conclusion: Percutaneous central venous catheterization via the internal jugular vein can be performed by interventional radiologists with better technical success rates and lower immediate complications. In conclusion, central venous catheterization for emergent dialysis should be performed under both real-time ultrasound and fluoroscopic guidance.

  2. Image-guided placement of port catheters: is there an increased risk of infection if the port is immediately accessed and used?

    Science.gov (United States)

    Salazar, Gloria; Yeddula, Kalpana; Wicky, Stephan; Oklu, Ramhi; Ganguli, Suvranu; Waltman, Arthur C; Walker, Thomas G; Kalva, Sanjeeva P

    2013-01-01

    To compare complication rates in patients who have port-a-catheters inserted and left accessed for immediate use and those who have ports inserted but not accessed. In this retrospective, IRB-approved study, medical records of patients who received a port catheter between 9/2009 and 2/2010 were reviewed. The data collected included patient demographics, diagnosis, procedure and complications. The patients were categorized into two groups: accessed (patients in whom the port was accessed with a Huber needle for immediate intravenous use and the patient left the procedure area with needle indwelling) and control (patients in whom the ports were not accessed). Complications were classified according to Society of Interventional Radiology guidelines. Results are given as mean ±SD. Statistical analysis was performed with student t test and statistical significance was considered at Pports were placed in 465 patients (Men: 206); 10.7% in the accessed group (n=50, age: 60±13.9) and 89.3% in the control group (n=417, age: 59±13.5). There were no statistically significant differences in patient demographics between the groups. The overall complication rate was 0.6% (n=3). Two complications (hematoma causing skin necrosis and thrombosis of the port) occurred in the control group and one (infection) in the accessed group. Infection rates after procedures were 2% (1/50) in the accessed group and 0% (0/417) in the control group. There was no statistically significant difference in overall complication (P=.1) and infection (P=.1) rates among the groups. Leaving the port accessed immediately after placement does not increase the risk of infection or other complications.

  3. Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

    International Nuclear Information System (INIS)

    Kulcsar, Zsolt; Yilmaz, Hasan; Bonvin, Christophe; Lovblad, Karl O.; Ruefenacht, Daniel A.

    2010-01-01

    In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted of an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.

  4. Validity of administrative database code algorithms to identify vascular access placement, surgical revisions, and secondary patency.

    Science.gov (United States)

    Al-Jaishi, Ahmed A; Moist, Louise M; Oliver, Matthew J; Nash, Danielle M; Fleet, Jamie L; Garg, Amit X; Lok, Charmaine E

    2018-03-01

    We assessed the validity of physician billing codes and hospital admission using International Classification of Diseases 10th revision codes to identify vascular access placement, secondary patency, and surgical revisions in administrative data. We included adults (≥18 years) with a vascular access placed between 1 April 2004 and 31 March 2013 at the University Health Network, Toronto. Our reference standard was a prospective vascular access database (VASPRO) that contains information on vascular access type and dates of placement, dates for failure, and any revisions. We used VASPRO to assess the validity of different administrative coding algorithms by calculating the sensitivity, specificity, and positive predictive values of vascular access events. The sensitivity (95% confidence interval) of the best performing algorithm to identify arteriovenous access placement was 86% (83%, 89%) and specificity was 92% (89%, 93%). The corresponding numbers to identify catheter insertion were 84% (82%, 86%) and 84% (80%, 87%), respectively. The sensitivity of the best performing coding algorithm to identify arteriovenous access surgical revisions was 81% (67%, 90%) and specificity was 89% (87%, 90%). The algorithm capturing arteriovenous access placement and catheter insertion had a positive predictive value greater than 90% and arteriovenous access surgical revisions had a positive predictive value of 20%. The duration of arteriovenous access secondary patency was on average 578 (553, 603) days in VASPRO and 555 (530, 580) days in administrative databases. Administrative data algorithms have fair to good operating characteristics to identify vascular access placement and arteriovenous access secondary patency. Low positive predictive values for surgical revisions algorithm suggest that administrative data should only be used to rule out the occurrence of an event.

  5. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    International Nuclear Information System (INIS)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416±45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency

  6. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo [Kyunghee University Hospital, seoul (Korea, Republic of)

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416{+-}45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency.

  7. Effect of Ultrasound-Guided Placement of Difficult-to-Place Peripheral Venous Catheters

    DEFF Research Database (Denmark)

    Partovi-Deilami, Kohyar; Nielsen, Jesper K.; Møller, Ann M.

    2016-01-01

    operated by nurse anesthetists for these patients. This prospective observational study with a pre/post design focused on inpatients with DIVA referred for PVC placement, a service provided by nurse anesthetists in most Scandinavian hospitals. The rate of success, procedure time, number of skin punctures......) with ultrasound. Procedure time was reduced from 20 to 10 minutes, discomfort was unchanged, and the median number of skin punctures decreased from 3 to 2. The incidence of central venous catheter placement dropped from 34% to 7%. Implementation of a training program and a mobile service in which nurse......, discomfort, catheter size, location, and incidence of central venous catheter placement are reported before and after implementation of a training program and a mobile service using ultrasound to place difficult-to-place PVCs. The success rate increased from 0% (0 of 33 patients) to 83% (58 of 70 patients...

  8. Preventing Inadvertent Placement of Foley Catheter into Prostatic ...

    African Journals Online (AJOL)

    Percutaneous suprapubic trocar cystostomy (SPC) is often needed to drain the bladder when urethral catheterization either fails or is not advisable.[1] It is ... vertical or slightly tilting its tip toward umbilicus during foley placement, prevents the inadvertent migration of catheter into prostatic urethra and further complications.

  9. Placement of a peripherally inserted central catheter into the azygous vein

    Energy Technology Data Exchange (ETDEWEB)

    Franklin, Iain, E-mail: iain.franklin@health.qld.gov.au; Gilmore, Christopher [The Prince Charles Hospital, Brisbane, Queensland (Australia)

    2015-06-15

    Peripherally inserted central catheters (PICC) are used for a variety of infusion therapies. They are indicated in patients requiring long-term venous access. Incorrect positioning of the insertion of a PICC line is one of the known complications when inserting the device in clinical practice. Radiographers once performing imaging will commonly check if the tip of a PICC has entered the superior vena cava. This case study will report on a lesser known incorrect placement of a PICC line into the azygous vein and how this can be detected on radiographic imaging. This outcome for the patient can be detrimental as it has an increased risk of perforation, thrombus, and fistula formation.

  10. A Randomized Controlled Trial of Music Use During Epidural Catheter Placement on Laboring Parturient Anxiety, Pain, and Satisfaction.

    Science.gov (United States)

    Drzymalski, Dan M; Tsen, Lawrence C; Palanisamy, Arvind; Zhou, Jie; Huang, Chuan-Chin; Kodali, Bhavani S

    2017-02-01

    Although music is frequently used to promote a relaxing environment during labor and delivery, the effect of its use during the placement of neuraxial techniques is unknown. Our study sought to determine the effects of music use on laboring parturients during epidural catheter placement, with the hypothesis that music use would result in lower anxiety, lower pain, and greater patient satisfaction. We conducted a prospective, randomized, controlled trial of laboring parturients undergoing epidural catheter placement with or without music. The music group listened to the patient's preferred music on a Pandora® station broadcast through an external amplified speaker; the control group listened to no music. All women received a standardized epidural technique and local anesthetic dose. The primary outcomes were 3 measures of anxiety. Secondary outcomes included pain, patient satisfaction, hemodynamic parameters, obstetric parameters, neonatal outcomes, and anesthesia provider anxiety. Intention-to-treat analysis with Bonferroni correction was used for the primary outcomes. For secondary outcomes, a P value of music group, the duration of music use was 31.1 ± 7.7 minutes (mean ± SD). The music group experienced higher anxiety as measured by Numeric Rating Scale scores immediately after epidural catheter placement (2.9 ± 3.3 vs 1.4 ± 1.7, mean difference 1.5 [95% confidence interval {CI} 0.2-2.7], P = .02), and as measured by fewer parturients being "very much relaxed" 1 hour after epidural catheter placement (51% vs 78%, odds ratio {OR} 0.3 [95% CI 0.1-0.9], P = .02). No differences in mean pain scores immediately after placement or patient satisfaction with the overall epidural placement experience were observed; however, the desire for music use with future epidural catheter placements was higher in the music group (84% vs 45%, OR 6.4 [95% CI 2.5-16.5], P Music use during epidural catheter placement in laboring parturients is associated with higher postprocedure

  11. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    International Nuclear Information System (INIS)

    Dasgupta, Niloy; Lungren, Matthew P.; Patel, Manish N.; Racadio, John M.; Johnson, Neil D.

    2016-01-01

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  12. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, Niloy; Lungren, Matthew P. [Lucile Packard Children' s Hospital Stanford, Department of Radiology, Palo Alto, CA (United States); Patel, Manish N.; Racadio, John M.; Johnson, Neil D. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-09-15

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  13. Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.

    Science.gov (United States)

    Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai

    2014-01-01

    Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.

  14. Postprocedural Aspiration Test to Predict Adequacy of Dialysis Following Tunneled Catheter Placement

    International Nuclear Information System (INIS)

    Smith, Jason C.; Sullivan, Kevin L.; Michael, Beckie

    2006-01-01

    The objective of the study was to determine if a timed aspiration technique with a 20-ml syringe can be used to predict adequacy of blood flow in tunneled dialysis catheters. Sixteen patients referred for de novo placement or manipulation of failing tunneled hemodialysis catheters had the time it takes to fill a 20-ml syringe with the plunger fully withdrawn measured to the nearest tenth of a second. These measurements were correlated with flow rates recorded in dialysis just prior to (if failed catheter) and in the following dialysis session with adequacy determined as at least 300 ml/min. Syringe-filling time (22 catheters in 16 patients) was plotted against adequacy of dialysis. The mean time to fill a 20-ml syringe was 2.2 sec, with a range of 1.0-4.7 sec. The mean time to fill syringes for catheters with adequate dialysis was 1.7 ± 0.5 sec, and for inadequate catheters, it was 2.8 ± 0.8 sec. These differences are statistically significant (p < 0.001). Using a filling time of greater than or equal to 2 sec as a threshold gives the highest sensitivity (100%) for predicting inadequate dialysis while maintaining high specificity (75%). To achieve a specificity of 100%, a 3-sec cutoff would be necessary, but would lead to a sensitivity of only 20%. A simple and objective aspiration technique can be performed at the time of tunneled dialysis catheter placement/manipulation to reasonably predict adequacy of subsequent dialysis

  15. Percutaneous catheter drainage of thoracic fluid: the usefulness and safety of bedside trocar placement under ultrasound guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Heon [Seoul Medical Center, Seoul (Korea, Republic of)

    2006-07-15

    The author wanted to evaluate the usefulness and safety of the trocar technique for US-guided bedside catheter placement into thoracic fluid collections, and this technique has generally been reserved for the larger or superficial fluid collections. 42 drainage procedures were performed in 38 patients at the bedside. The patients were positioned supine or semi-upright. A drainage catheter system with a stylet and cannula assembly was used and all of the catheters were inserted using the trocar technique. The procedures consisted of drainage of empyema (n=14), malignant effusion (n=13), lung abscess (n=3), massive transudate (n=8), hemothorax (n=2) and chest wall hematoma (n=2). The clinical results were classified as successful (complete and partially successful), failure or undetermined. The medical records and images were retrospectively reviewed to evaluate the success rate, the complications and the procedure time. Technical success was achieved in all of the 42 procedures. With using the trocar technique, all the catheters were placed into even the small collections without significant complications. Drainage was successful in 36 (85.7%) of the 42 procedures. The average volume of thoracic fluid that was aspirated manually at the time of catheter placement was 420 mL (range: 35 to 1470 mL). The procedure time was less than 10 minutes from US-localization to complete catheter placement in all of the procedures. The trocar technique under US guidance can be an efficient and safe alternative to the Seldinger or guide-wire exchange technique for bedside catheter placement in the critically ill or hemodynamically unstable patients.

  16. Effect of Isometric Hand Grip Exercises on Blood Flow and Placement of IV Catheters for Administration of Chemotherapy.

    Science.gov (United States)

    Ozkaraman, Ayse; Yesilbalkan, Öznur Usta

    2016-04-01

    Complications may occur in the subcutaneous or subdermal tissues during IV administration of chemotherapy related to blood flow and catheter placement. Daily isometric hand grip exercises were evaluated for their effect on blood flow in the vessels of the nondominant arm before placement of IV catheters and the success rate of IV catheter placement on the first attempt. The study focused on patients with non-Hodgkin lymphoma receiving the first and second cycles of chemotherapy. The intervention group performed daily isometric hand grip exercises before chemotherapy with peripheral catheter insertion. The control group performed routine activities only. Blood flow was measured by ultrasound in the brachial artery (BA) and brachial vein (BV) of the nondominant arm before the first (T1) and second (T2) cycles of chemotherapy. Blood flow slightly increased in the intervention group at T2 compared to T1. In the control group, blood flow decreased in the BA and did not change in the BV at T2 compared to T1. The success rate for first-attempt placement of a peripheral IV catheter was the same for the intervention and control groups.

  17. US-guided placement of temporary internal jugular vein catheters: immediate technical success and complications in normal and high-risk patients

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Kara, Gulcan; Torun, Dilek; Kizilkilic, Osman; Yildirim, Tulin

    2005-01-01

    Objective: : To evaluate the technical success and immediate complication rates of temporary internal jugular vein (IJV) haemodialysis catheter placement in normal and high-risk patients. Methods and materials: Two-hundred and twenty temporary internal jugular vein catheters inserted under ultrasound guidance in 172 patients were prospectively analyzed. Of 172 patients, 93 (54%) were males and 79 (46%) were females (age range, 18-83; mean, 56.0 years). Of 220 catheters, 171 (78%) were placed in patients who had a risk factor for catheter placement like patients with disorder of haemostasis, poor compliance, and previous multiple catheter insertion in the same IJV. Forty-seven (21.3%) procedures were performed on bed-side. A catheter was inserted in the right IJV in 178 procedures (80.9%) and left IJV in 42 procedures. Of 172 patients, 112 (65%) had only one catheter placement and the rest had had more than one catheter placement (range, 1-5). Results: Technical success was achieved in all patients (100%). Average number of puncture was 1.24 (range, 1-3). One hundred and eighty-three insertions (83.1%) were single-wall punctures, whereas 37 punctures were double wall punctures. Nine (4%) minor complications were encountered. Inadvertent carotid artery puncture without a sequel in four procedures (1.8%), oozing of blood around the catheter in three procedures (1.4%), a small hematoma in one procedure (0.4%), and puncture through the pleura in one procedure (0.4%) without development of pneumothorax. Oozing of blood was seen only in patients with disorder of haemostasis. Conclusion: Ultrasound-guided placement of internal jugular vein catheters is very safe with very high success rate and few complications. It can safely be performed in high-risk patients, like patients with disorders of haemostasis and patients with previous multiple catheter insertion in the same vein

  18. Simplified Surgical Placement of Tenckhoff Catheter under Local Anesthesia: The Dammam Central Hospital Experience

    Directory of Open Access Journals (Sweden)

    Youmbissi T

    2001-01-01

    Full Text Available Many methods are used for the placement of Tenckhoff catheters. Eighteen consecutive Tenckhoff catheters were placed under local anesthesia through a mini laparotomy with a reduced operating team. There were only three total catheter failures. Complications were infrequent and operating time was less than one hour on average. This simple procedure should be a part of the training program of all junior surgeons and nephrologists.

  19. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  20. Resection of deep-seated gliomas using neuroimaging for stereotactic placement of guidance catheters

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Kengo; Higashi, Hisato; Tomita, Susumu; Furuta, Tomohisa; Ohmoto, Takashi [Okayama Univ. (Japan). School of Medicine

    1995-03-01

    A simple computed tomography- (CT) or magnetic resonance (MR) imaging-guided stereotactic method for guided microsurgical resection of either deep-seated gliomas or tumors adjacent to an eloquent area is described. The technique employs the Brown-Roberts-Wells stereotactic system and twist drills, 2.7 mm in diameter, for the stereotactic placement of 2.4 mm diameter scaled guidance catheters through the calvaria. In a patient with a deep-seated small glioma, less than 2 cm diameter, one catheter was implanted into the center of the enhanced mass through the cerebral cortex. In the other 14 patients, three to six catheters were used which made the tumor border clearer. After implantation of the guidance catheters, the stereotactic frame was removed and a standard open craniotomy performed. Target localization is not affected by brain movement, which is inevitable during open surgery. The tumor involved the frontal lobe in eight patients, the parietal lobe in two, and the thalamus in five. In all cases the lesion was quickly localized and radical removal was acheived. Neurological complications occurred in only one patient who suffered transient hemiparesis after the resection of a lesion in the pyramidal tract. The results demonstrate that microsurgery combined with CT- or MR imaging-guided stereotactic placement of guidance catheters is a new option for surgery of deep-seated gliomas or tumors adjacent to an eloquent area. (author).

  1. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  2. A COMPARATIVE ANALYSIS OF PERCUTANEOUS AND OPEN SURGICAL TECHNIQUESFOR PERITONEAL CATHETER PLACEMENT.

    LENUS (Irish Health Repository)

    Medani, Samar

    2012-05-01

    BACKGROUND: Peritoneal dialysis (PD) is the preferred available option of renal replacement therapy for a significant number of end-stage kidney disease patients. A major limiting factor to the successful continuation of PD is the long-term viability of the PD catheter (PDC). Bedside percutaneous placement of the PDC is not commonly practiced despite published data encouraging use of this technique. Its advantages include faster recovery and avoidance of general anesthesia.♢ METHODS: We carried out a retrospective analysis of the outcomes of 313 PDC insertions at our center, comparing all percutaneous PDC insertions between July 1998 and April 2010 (group P, n = 151) with all surgical PDC insertions between January 2003 and April 2010 (group S, n = 162).♢ RESULTS: Compared with group P patients, significantly more group S patients had undergone previous abdominal surgery or PDC insertion (41.8% vs 9.3% and 33.3% vs 3.3% respectively, p = 0.00). More exit-site leaks occurred in group P than in group S (20.5% vs 6.8%, p = 0.002). The overall incidence of peritonitis was higher in group S than in group P (1 episode in 19 catheter-months vs 1 episode in 26 catheter-months, p = 0.017), but the groups showed no significant difference in the peritonitis rate within 1 month of catheter insertion (5% in group P vs 7.4% in group S, p =0.4) or in poor initial drainage or secondary drainage failure (9.9% vs 11.7%, p = 0.1, and 7.9% vs 12.3%, p = 0.38, for groups P and S respectively). Technical survival at 3 months was significantly better for group P than for group S (86.6% vs 77%, p = 0.037); at 12 months, it was 77.7% and 68.7% respectively (p = 0.126). No life-threatening complications attributable to the insertion of the PDC occurred in either group.♢ CONCLUSIONS: Our analysis demonstrates further encouraging outcomes of percutaneous PDC placement compared with open surgical placement. However, the members of the percutaneous insertion group were primarily a

  3. A system for visualization and automatic placement of the endoclamp balloon catheter

    Science.gov (United States)

    Furtado, Hugo; Stüdeli, Thomas; Sette, Mauro; Samset, Eigil; Gersak, Borut

    2010-02-01

    The European research network "Augmented Reality in Surgery" (ARIS*ER) developed a system that supports minimally invasive cardiac surgery based on augmented reality (AR) technology. The system supports the surgical team during aortic endoclamping where a balloon catheter has to be positioned and kept in place within the aorta. The presented system addresses the two biggest difficulties of the task: lack of visualization and difficulty in maneuvering the catheter. The system was developed using a user centered design methodology with medical doctors, engineers and human factor specialists equally involved in all the development steps. The system was implemented using the AR framework "Studierstube" developed at TU Graz and can be used to visualize in real-time the position of the balloon catheter inside the aorta. The spatial position of the catheter is measured by a magnetic tracking system and superimposed on a 3D model of the patient's thorax. The alignment is made with a rigid registration algorithm. Together with a user defined target, the spatial position data drives an actuator which adjusts the position of the catheter in the initial placement and corrects migrations during the surgery. Two user studies with a silicon phantom show promising results regarding usefulness of the system: the users perform the placement tasks faster and more accurately than with the current restricted visual support. Animal studies also provided a first indication that the system brings additional value in the real clinical setting. This work represents a major step towards safer and simpler minimally invasive cardiac surgery.

  4. Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement

    International Nuclear Information System (INIS)

    Gonsalves, Carin F.; Eschelman, David J.; Sullivan, Kevin L.; DuBois, Nancy; Bonn, Joseph

    2003-01-01

    The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices

  5. Lumbar epidural catheter placement in the presence of low back tattoos: a review of the safety concerns.

    Science.gov (United States)

    Welliver, Dawn; Welliver, Mark; Carroll, Tammy; James, Peggy

    2010-06-01

    Current fashion in body art includes low back tattoos of varying designs and colors, a trend that presents unique concerns for anesthesia providers. Does the placement of epidural catheters risk the introduction of tattoo pigment dyes into the epidural space through the process of coring? Are there specific risks associated with tattoo dyes and epidural needle placement? We performed a comprehensive review of the literature using multiple search databases with the intent to form guidelines for practice using a level of evidence taxonomy. The available evidence does not identify any specific risks associated with epidural catheter placement through low back tattoos, although tissue coring with tissue transport to deeper sites has been confirmed. Continued investigation is necessary before comprehensive practice guidelines regarding the practice of placing epidural needles and catheters through lumbar tattoos can be developed. We suggest avoidance of piercing tattoos when performing epidural punctures until there is sound evidence of short-term and long-term safety.

  6. A Brief Recap of Tips and Surgical Manoeuvres to Enhance Optimal Outcome of Surgically Placed Peritoneal Dialysis Catheters

    Directory of Open Access Journals (Sweden)

    Jodie H. Frost

    2012-01-01

    Full Text Available Background. Peritoneal dialysis (PD is an effective option of renal replacement therapy for ESRF, offering advantages over haemodialysis. Peritoneal dialysis catheter (PDC placement is thought to be the key to successful PD and the economic advantages are lost if a patient switches to HD in the 1st year. This paper is a brief document elaborating a recap of published literature, looking at various surgical tips and manoeuvres to enhance optimal outcome of PDC placement. Methods. A search strategy assessing for access team, preoperative antibiotic prophylaxis, type of catheter, catheter exit site, intraoperative catheter trial, optimal time to commence PD, hernia repairs, number of cuffs, catheter-embedding procedures, rectus sheath tunnelling, laparoscopic fixing, omentopexy, omentectomy, the “Y”-Tec system, resection of epiploic appendages, adhesiolysis, a trained surgeon, and perioperative catheter care protocol was used looking at various databases. Findings. The complications of catheterrelated dysfunction can be reduced with advanced planning of access placement, immaculate surgery, and attention to catheter insertion techniques. Conclusion. The success of a peritoneal dialysis programme depends upon functional and durable long term access to the peritoneal cavity; this depends on placement techniques and competent surgeons and psychosocial support to the patient. The various technical tips and manoeuvres elaborated here should be considered options carried out to improve outcome and reduce catheter dysfunction.

  7. Measurements of Epidural Space Depth Using Preexisting CT Scans Correlate with Loss of Resistance Depth during Thoracic Epidural Catheter Placement

    Directory of Open Access Journals (Sweden)

    Nathaniel H. Greene

    2015-01-01

    Full Text Available Background. Thoracic epidural catheters provide the best quality postoperative pain relief for major abdominal and thoracic surgical procedures, but placement is one of the most challenging procedures in the repertoire of an anesthesiologist. Most patients presenting for a procedure that would benefit from a thoracic epidural catheter have already had high resolution imaging that may be useful to assist placement of a catheter. Methods. This retrospective study used data from 168 patients to examine the association and predictive power of epidural-skin distance (ESD on computed tomography (CT to determine loss of resistance depth acquired during epidural placement. Additionally, the ability of anesthesiologists to measure this distance was compared to a radiologist, who specializes in spine imaging. Results. There was a strong association between CT measurement and loss of resistance depth (P35 changed this relationship (P=0.007. The ability of anesthesiologists to make CT measurements was similar to a gold standard radiologist (all individual ICCs>0.9. Conclusions. Overall, this study supports the examination of a recent CT scan to aid in the placement of a thoracic epidural catheter. Making use of these scans may lead to faster epidural placements, fewer accidental dural punctures, and better epidural blockade.

  8. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  9. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  10. The Nelaton Catheter Guard for Safe and Effective Placement of Subdural Drain for Two-Burr-Hole Trephination in Chronic Subdural Hematoma: A Technical Note.

    Science.gov (United States)

    Fichtner, Jens; Beck, Jürgen; Raabe, A; Stieglitz, Lennart Henning

    2015-09-01

    For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain. Georg Thieme Verlag KG Stuttgart · New York.

  11. Superselective intra-arterial infusion via the superficial temporal artery and occipital artery for gingival carcinoma of the mandible. Simultaneous catheter placement to the maxillary artery and facial artery

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Mitsudo, Kenji; Fukui, Takafumi

    2009-01-01

    Superselective intra-arterial infusion via the superficial temporal artery (STA) has become useful for oral cancer. Approaching via the occipital artery (OA) enables superselective intra-arterial infusion when catheter placement via the STA is impossible. Therefore, simultaneous catheter placement via the STA and OA is possible. We report a surgical method of simultaneous catheter placement via the STA and OA to achieve retrograde superselective intra-arterial infusion for gingival carcinoma of the mandible. Preoperatively, three-dimensional computed tomography angiography was performed to identify the route of the external carotid artery and branches such as the STA, OA, maxillary artery, and facial artery (FA). Thirteen patients with mandibular gingival cancer underwent catheter placement via the STA and OA under local anesthesia. Catheter placement via the STA and OA was superselectively successful in all the patients. The mean operating time was 150.8 min. Catheter placed to the FA via the OA was dislocated during the treatment in one patient, and so the catheter was replaced. This method is useful to enable superselective intra-arterial chemotherapy to the whole gingival carcinoma of the mandible from the start of treatment compared with approaching via the STA. (author)

  12. Laparoscopic Placement of Peritoneal Dialysis Catheters in CAPD Patients: Complications and Survival

    Directory of Open Access Journals (Sweden)

    A Roueentan

    2008-06-01

    Full Text Available Background: Laparoscopic techniques for the placement of peritoneal dialysis catheters are becoming increasingly popular. Recently, with the improvements in laparoscopic surgery, various methods for the insertion of peritoneal dialysis catheters have been reported, indicating that the laparoscopic insertion is preferred over the open and percutaneous techniques. The aim of this study was to introduce and assess a simplified laparoscopic method for the insertion of peritoneal dialysis catheters in continuous ambulatory peritoneal dialysis (CAPD patients.Methods: We enrolled 79 consecutive end-stage renal patients (46 men and 33 women with a mean age of 50 years (range: 19-83 years in this study. During the surgery, a 5-mm trocar was placed in the left upper quadrant for the optics and another 5-mm trocar was placed to the left of the umbilicus. Using the second trocar, a tunnel was formed 2 cm left of the umbilical plane for the insertion of a Tenckhoff catheter. Under direct vision, the catheter was advanced into the abdomen. The catheter was tested for patency. Catheters of all subjects were capped for two weeks before dialysis initiation.Results: The mean duration of the operation was 15 minutes. Ten patients died during the follow-up period, all due to other medical problems, and six patients underwent renal transplantation; however, no deaths or complications were observed during surgery. Early onset complications were seen in 12 patients (15.1%. The most frequent late-onset medical and mechanical complications were peritonitis (6.3% and hernia (3.7%. During a follow-up period of four years, removal of the catheter was required in two patients as a result of peritonitis.Conclusion: We obtained a low complication rate and a high catheter survival rate with this laparoscopic insertion of the Tenckhoff catheter. We believe future experience will encourage the use of this safe, simple and quick procedure.

  13. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  14. Real-Time 3-Dimensional Ultrasound-Assisted Infraclavicular Brachial Plexus Catheter Placement: Implications of a New Technology

    Directory of Open Access Journals (Sweden)

    Steven R. Clendenen

    2010-01-01

    Full Text Available Background. There are a variety of techniques for targeting placement of an infraclavicular blockade; these include eliciting paresthesias, nerve stimulation, and 2-dimensional (2D ultrasound (US guidance. Current 2D US allows direct visualization of a “flat” image of the advancing needle and neurovascular structures but without the ability to extensively analyze multidimensional data and allow for real-time manipulation. Three-dimensional (3D ultrasonography has gained popularity and usefulness in many clinical specialties such as obstetrics and cardiology. We describe some of the potential clinical applications of 3D US in regional anesthesia. Methods. This case represents an infraclavicular catheter placement facilitated by 3D US, which demonstrates 360-degree spatial relationships of the entire anatomic region. Results. The block needle, peripheral nerve catheter, and local anesthetic diffusion were observed in multiple planes of view without manipulation of the US probe. Conclusion. Advantages of 3D US may include the ability to confirm correct needle and catheter placement prior to the injection of local anesthetic. The spread of local anesthetic along the length of the nerve can be easily observed while manipulating the 3D images in real-time by simply rotating the trackball on the US machine to provide additional information that cannot be identified with 2D US alone.

  15. Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

    International Nuclear Information System (INIS)

    Fujita, Takeshi; Tanabe, Masahiro; Yamatogi, Shigenari; Shimizu, Kensaku; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57–93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 ± 13 (SD) min (range 24–78). The average follow-up time interval was 103 days (range 7–812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

  16. Decreasing dialysis catheter rates by creating a multidisciplinary dialysis access program.

    Science.gov (United States)

    Rosenberry, Patricia M; Niederhaus, Silke V; Schweitzer, Eugene J; Leeser, David B

    2018-03-01

    Centers for Medicare and Medicaid Services have determined that chronic dialysis units should have 45%. A multidisciplinary program was established with goals of decreasing catheter rates in order to decrease central line-associated bloodstream infections, decrease mortality associated with central line-associated bloodstream infection, decrease hospital days, and provide savings to the healthcare system. We collected the catheter rates within three dialysis centers served over a 5-year period. Using published data surrounding the incidence and related costs of central line-associated bloodstream infection and mortality per catheter day, the number of central line-associated bloodstream infection events, the costs, and the related mortality could be determined prior to and after the initiation of the dialysis access program. An organized dialysis access program resulted in a 82% decrease in the number of central venous catheter days which lead to a concurrent reduction in central line-associated bloodstream infection and deaths. As a result of creating an access program, central venous catheter rates decreased from an average rate of 45% to 8%. The cost savings related to the program was calculated to be over US$5 million. The decrease in the number of mortalities is estimated to be between 13 and 27 patients. We conclude that a formalized access program decreases catheter rates, central line-associated bloodstream infection, and the resultant hospitalizations, mortality, and costs. Areas with high hemodialysis catheter rates should develop access programs to better serve their patient population.

  17. Serious Gaming to Improve the Safety of Central Venous Catheter Placement

    Directory of Open Access Journals (Sweden)

    Daniel Katz

    2013-06-01

    Full Text Available Approximately 5 million central venous catheters (CVCs are placed by physicians annually in the United States, with a complication rate of 15%.1 Guidelines and recommendations are continually being established and updated regarding CVC placement.2 While much has been done regarding training the technical skills of CVC placement using part-task trainers (i.e., mannequins, successfully finding and cannulating a central vein is but one part of the process. In fact, many steps designed to prevent untoward complications involve non-technical skills which are perhaps more important in training practitioners to safely place CVCs. First in aviation and now in healthcare, practitioners are being trained in realistic and highly interactive simulated environments so they can learn not just technical skills , but the key management and non-technical steps which make their task safer.3 One modality being used to improve performance is video gaming simulation, or "serious gaming." Gaming as a learning tool is being increasingly utilized in health care fields and can lead to better skill-based outcomes.4 As such, we have developed a game based around the placement of CVCs that will be used as a new teaching modality in a pilot program for instructing residents in safe CVC placement.

  18. Principles of subcutaneous port placement.

    Science.gov (United States)

    Gonda, Shaun J; Li, Ruizong

    2011-12-01

    The introduction of totally implantable subcutaneous devices in the early 1980s provided patients with secure, reliable venous access and also gave them the ability to move more freely and have a more normal lifestyle with these devices in place. The most common totally implantable device used today is the subcutaneous port. These ports consist of an injection port connected to a catheter. Ports provide a number of advantages compared with other venous catheters; the most important is the reduced risk of infection. These devices have significantly lower rates of infection than nontunneled and tunneled catheters. Additional advantages include less frequent irrigation and minimal home care, and they are less prone to environmental or cutaneous contamination when not being accessed. This article will focus on the placement of these ports. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  20. Malfunctioning and infected tunneled infusion catheters: over-the-wire catheter exchange versus catheter removal and replacement.

    Science.gov (United States)

    Guttmann, David M; Trerotola, Scott O; Clark, Timothy W; Dagli, Mandeep; Shlansky-Goldberg, Richard D; Itkin, Maxim; Soulen, Michael C; Mondschein, Jeffrey I; Stavropoulos, S William

    2011-05-01

    To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P = .049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P = .73). Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be

  1. Intraventricular catheter placement by electromagnetic navigation safely applied in a paediatric major head injury patient.

    Science.gov (United States)

    Aufdenblatten, Christoph Alexander; Altermatt, Stefan

    2008-09-01

    In the management of severe head injuries, the use of intraventricular catheters for intracranial pressure (ICP) monitoring and the option of cerebrospinal fluid drainage is gold standard. In children and adolescents, the insertion of a cannula in a compressed ventricle in case of elevated intracranial pressure is difficult; therefore, a pressure sensor is placed more often intraparenchymal as an alternative option. In cases of persistent elevated ICP despite maximal brain pressure management, the use of an intraventricular monitoring device with the possibility of cerebrospinal fluid drainage is favourable. We present the method of intracranial catheter placement by means of an electromagnetic navigation technique.

  2. Epidemiology of peritonitis following maintenance peritoneal dialysis catheter placement during infancy: a report of the SCOPE collaborative.

    Science.gov (United States)

    Zaritsky, Joshua Jacob; Hanevold, Coral; Quigley, Raymond; Richardson, Troy; Wong, Cynthia; Ehrlich, Jennifer; Lawlor, John; Rodean, Jonathan; Neu, Alicia; Warady, Bradley A

    2018-04-01

    Maintenance peritoneal dialysis (PD) is the dialysis modality of choice for infants and young children. However, there are limited outcome data for those who undergo PD catheter insertion and initiate maintenance PD within the first year of life. Using data from the Children's Hospital Association's Standardizing Care to Improve Outcomes in Pediatric End Stage Renal Disease (ESRD) Collaborative (SCOPE), we examined peritonitis rates and patient survival in 156 infants from 29 North American pediatric dialysis centers who had a chronic PD catheter placed prior to their first birthday. In-hospital and overall annualized rates of peritonitis were 1.73 and 0.76 episodes per patient-year, respectively. Polycystic kidney disease was the most frequent renal diagnosis and pulmonary hypoplasia the most common co-morbidity in infants with peritonitis. Multivariable regression models demonstrated that nephrectomy at or prior to PD catheter placement and G-tube insertion after catheter placement were associated with a nearly sixfold and nearly threefold increased risk of peritonitis, respectively. Infants with peritonitis had longer initial hospital stays and lower overall survival (86.3 vs. 95.6%, respectively; P high and several risk factors associated with the development of peritonitis were identified. Given that peritonitis was associated with a longer duration of initial hospitalization and increased mortality, increased attention to the potentially modifiable risk factors for infection is needed.

  3. Initial placement and secondary displacement of a new suture-method catheter for sciatic nerve block in healthy volunteers

    DEFF Research Database (Denmark)

    Lyngeraa, T S; Rothe, C; Steen-Hansen, C

    2017-01-01

    electromyography and cold sensation. After return of motor and sensory function, volunteers performed standardised physical exercises; injection of the same study medication was repeated in the same leg and followed by motor and sensory assessments. Fifteen of 16 (94%; 95%CI 72-99%) initial catheter placements...... displacement was 5 mm. Catheters with secondary block failure were displaced between 6 and 10 mm. One catheter was displaced 1.8 mm that resulted in a decrease in maximum voluntary isometric contraction of less than 20%. After repeat test injection, 14 of the 16 volunteers had loss of cold sensation. Neither...

  4. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    Science.gov (United States)

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  5. Repeated peritoneal catheter blockage caused by neurocysticercosis following ventriculoperitoneal shunt placement for hydrocephalus

    Directory of Open Access Journals (Sweden)

    Zhi Hua Li

    2018-01-01

    Full Text Available Cerebral cysticercosis is common, but the possibility for repeated occurrence of peritoneal catheter blockage caused by neurocysticercosis (NCC after two revisions following ventriculoperitoneal shunt placement for hydrocephalus is unusual. Herein, we describe one rare case in which peritoneal catheter revision was performed two times unsuccessfully. Endoscopic cysternostomy rather than peritoneal catheter adjustment was performed successfully, and histopathological examination of excised cystic samples confirmed NCC in our hospital. The present case highlights the need for awareness of NCC as a possible etiology of hydrocephalus, especially in developing countries. Uncommon findings in both lateral ventricles following low-field magnetic resonance imaging scans as well as the rarity of this infection involved in unusual location play important roles in misdiagnosis and incorrect treatment for hydrocephalus; thus, endoscopic cysternostomy, rather than multiple shunt adjustment of the peritoneal end, is recommended in the selected patient. To the best of our knowledge, this is the first report describing the misdiagnosis and inappropriate treatment of hydrocephalus caused by cerebral cysticercosis in China.

  6. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  7. A Case of Unrecognized Intrathoracic Placement of a Subclavian Central Venous Catheter in a Patient with Large Traumatic Hemothorax

    Directory of Open Access Journals (Sweden)

    Dina Wallin

    2015-01-01

    Full Text Available Traditional recommendations suggest placement of a subclavian central venous catheter (CVC ipsilateral to a known pneumothorax to minimize risk of bilateral pneumothorax. We present the case of a 65-year-old male with a right hemopneumothorax who was found to have intrathoracic placement of his right subclavian CVC at thoracotomy despite successful aspiration of blood and transduction of central venous pressure (CVP. We thus recommend extreme caution with the interpretation of CVC placement by blood aspiration and CVP measurement alone in patients with large volume ipsilateral hemothorax.

  8. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    Science.gov (United States)

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  9. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    Science.gov (United States)

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  10. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    Energy Technology Data Exchange (ETDEWEB)

    Walser, Eric M., E-mail: walser.eric@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2012-08-15

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

  11. Randomized Controlled Trial Comparing Open Versus Laparoscopic Placement of a Peritoneal Dialysis Catheter and Outcomes: The CAPD I Trial.

    Science.gov (United States)

    van Laanen, Jorinde H H; Cornelis, Tom; Mees, Barend M; Litjens, Elisabeth J; van Loon, Magda M; Tordoir, Jan H M; Peppelenbosch, Arnoud G

    2018-01-01

    To determine the best operation technique, open versus laparoscopic, for insertion of a peritoneal dialysis (PD) catheter with regard to clinical success. Clinical success was defined as an adequate function of the catheter 2 - 4 weeks after insertion. All patients with end-stage renal disease who were suitable for PD and gave informed consent were randomized for either open surgery or laparoscopic surgery. A previous laparotomy was not considered an exclusion criterion. Laparoscopic placement had the advantage of pre-peritoneal tunneling, the possibility for adhesiolysis, and placement of the catheter under direct vision. Catheter fixation techniques, omentopexy, or other adjunct procedures were not performed. Other measured parameters were in-hospital morbidity and mortality and post-operative infections. Between 2010 and 2016, 95 patients were randomized to this study protocol. After exclusion of 5 patients for various reasons, 44 patients received an open procedure and 46 patients a laparoscopic procedure. Gender, age, body mass index (BMI), hypertension, current hemodialysis, severe heart failure, and previous an abdominal operation were not significantly different between the groups. However, in the open surgery group, fewer patients had a previous median laparotomy compared with the laparoscopic group (6 vs 16 patients; p = 0.027). There was no statistically significant difference in mean operation time (36 ± 24 vs 38 ± 15 minutes) and hospital stay (2.1 ± 2.7 vs 3.1 ± 7.3 days) between the groups. In the open surgery group 77% of the patients had an adequate functioning catheter 2 - 4 weeks after insertion compared with 70% of patients in the laparoscopic group ( p = not significant [NS]). In the open surgery group there was 1 post-operative death (2%) compared with none in the laparoscopic group ( p = NS). The morbidity in both groups was low and not significantly different. In the open surgery group, 2 patients had an exit-site infection and 1 patient

  12. [Fistulae or catheter for elderly who start hemodialysis without permanent vascular access?].

    Science.gov (United States)

    García Cortés, Ma J; Viedma, G; Sánchez Perales, M C; Borrego, F J; Borrego, J; Pérez del Barrio, P; Gil Cunquero, J M; Liébana, A; Pérez Bañasco, V

    2005-01-01

    Autologous access is the best vascular access for dialysis also in older patients and it should be mature when patient needs hemodialysis. It is not always possible. Surgeon availability and demographic characteristics of patients (age, diabetes, vascular disease...) are factors that determine primary vascular access. To analyse outcome and vascular access complications in elderly who start hemodialysis without vascular access. All patients older than 75 years who initiated hemodialysis without vascular access between January 2000 and June 2002 were included, They were divided en two groups depending on primary vascular access. GI: arterio-venous fistulae. GIIl: Tunnelled cuffed catheter. Epidemiological and analytical data, vascular access complications related, as well as patient and first permanent vascular access survival from their inclusion in dialysis up to December 2002 were analysed and compared in both groups. 32 patients were studied. GI: n = 17 (4 men) and GIIl: n =1 5 (8 men), age: 79.9 +/- 3.8 and 81.7 +/- 4 years respectively (ns). There were no differences in sex and comorbidity (diabetes, ischemic heart disease, peripheral vascular disease and hypertension). It took GI 3 months to get a permanent vascular access suitable for using, while it took GIIl 1.3 months (p catheters was higher in GI (3.35 vs 1.87 p central venous thrombosis happen in GI (I: 25 CVT/100 patients-year) vs 30% in GIIl (I = 14.4/100 patients-year) (ns). No significant differences neither in bleeding (66.7% vs 33.3%) nor ischemia (75% vs 25%) were found. Dialysis dose (Kt/V) as well as anaemia degree were similar in both groups. Permanent vascular access survival after 2 years was 45.8% in GI and 24% in GII (ns). Patient survival was similar in GI and GII (72% vs 51% ns). Elderly who start hemodialysis without vascular access took longer to get a suitable permanent vascular access when arterio-venous fistulae is placed than with a tunnelled cuffed hemodialysis catheter. As a

  13. Development and Implementation of an Ultrasound-Guided Peripheral Intravenous Catheter Program for Emergency Nurses.

    Science.gov (United States)

    Edwards, Courtney; Jones, Jodi

    2018-01-01

    Emergency medical care often necessitates placement of peripheral intravenous (PIV) catheters. When traditional methods for obtaining PIV access are not successful, ultrasound guidance is a rescue technique for peripheral vascular placement that improves the quality of patient care. The aim of this training program was to develop a process where emergency nurses would be competent to perform ultrasound guided PIV to improve the quality of patient care delivered while reducing throughput time. Administrative program development required creating a nursing practice statement, procedure guideline, operational plan, and competency validation. A training program comprising both didactic and hands-on training was developed and provided by emergency medicine physicians with formal ultrasound fellowship training. In determining whether the training program was adequate in preparing the student to place an ultrasound-guided PIV, 92.9% of students "agreed" or "strongly agreed." In having confidence in their ability to obtain an ultrasound guided PIV catheter placement, 35.7% of respondents "agreed" and 64.3% "strongly agreed." In finding it difficult to be successful in achieving ultrasound guided PIV catheter placement, 71.4% of students "strongly disagreed" and 14.3% "disagreed." All students (100%) felt it was a feasible task to train nurses to successfully place ultrasound-guided PIV catheters and 71.4% of students strongly support continuing to provide this training program and competency validation. Establishment of an effective didactic and hands-on training program resulted in emergency department nurses becoming competent in placement of ultrasound guided PIV catheters to provide optimal patient care. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  14. Interventional radiology in the provision and maintenance of long-term central venous access

    International Nuclear Information System (INIS)

    Lyon, S.M.; Given, M.; Marshall, N.L.

    2008-01-01

    Establishing and maintaining venous access forms an increasing proportion of the workload in interventional radiology. Several patient groups require medium-term to long-term venous catheters for a variety of purposes, including chemotherapy, long-term antimicrobials, parenteral nutrition, short-term access for haemodialysis or exhausted haemodialysis. Often, these catheters are required for treatment and frequent blood testing, which can quickly exhaust the peripheral veins. Venous access devices include implantable catheters (ports), tunnelled catheters and peripherally inserted central catheters, which have different functions, advantages and limitations. Imaging-guided placement is the preferred method of insertion in many institutions because of higher success rates and radiologists are well suited to address catheter complications.

  15. Comparison of two indwelling central venous access catheters in dogs undergoing fractionated radiotherapy

    International Nuclear Information System (INIS)

    Evans, K.L.; Smeak, D.D.; Couto, C.G.; Hammer, A.S.; Gaynor, J.S.

    1994-01-01

    Twenty dogs with neoplasms requiring multiple radiation treatments received either percutaneous vascular access catheters (PVACs; Cook, Bloomington, IN) or subcutaneous vascular access ports (SVAPs; Vascular-Access-Ports, Norfolk Medical Products, Inc., Skokie, IL); 10 dogs were entered in each group. All catheters were implanted and removed aseptically and the catheter tips were cultured during implant removal. Complications with PVACs included mild incisional swelling and redness and accidental severance or rupture of the catheter. Complications with SVAPs included incisional or port swelling, bruising or redness, hematoma formation, and pain. Ports in 4 of these dogs could not be used for 1 to 3 days after surgery because of swelling and pain. Surgical wound complications, when pooled for comparison, occurred significantly more frequently with the SVAPs (P = .023). Wound complications associated with both catheters were self-limiting and resolved within 7 days. Bacterial cultures were positive in two PVACs and four SVAP tips, however, none of these dogs had clinical signs of infection or sepsis. Although both types of indwelling catheters were functional in a clinical setting, PVACs were preferred to SVAPs for dogs undergoing radiation therapy because of decreased time for implantation and fewer overall complications

  16. Incidence of catheter-related complications in patients with central venous or hemodialysis catheters: a health care claims database analysis.

    Science.gov (United States)

    Napalkov, Pavel; Felici, Diana M; Chu, Laura K; Jacobs, Joan R; Begelman, Susan M

    2013-10-16

    Central venous catheter (CVC) and hemodialysis (HD) catheter usage are associated with complications that occur during catheter insertion, dwell period, and removal. This study aims to identify and describe the incidence rates of catheter-related complications in a large patient population in a United States-based health care claims database after CVC or HD catheter placement. Patients in the i3 InVision DataMart® health care claims database with at least 1 CVC or HD catheter insertion claim were categorized into CVC or HD cohorts using diagnostic and procedural codes from the US Renal Data System, American College of Surgeons, and American Medical Association's Physician Performance Measures. Catheter-related complications were identified using published diagnostic and procedural codes. Incidence rates (IRs)/1000 catheter-days were calculated for complications including catheter-related bloodstream infections (CRBSIs), thrombosis, embolism, intracranial hemorrhage (ICH), major bleeding (MB), and mechanical catheter-related complications (MCRCs). Thirty percent of the CVC cohort and 54% of the HD cohort had catheter placements lasting <90 days. Catheter-related complications occurred most often during the first 90 days of catheter placement. IRs were highest for CRBSIs in both cohorts (4.0 [95% CI, 3.7-4.3] and 5.1 [95% CI, 4.7-5.6], respectively). Other IRs in CVC and HD cohorts, respectively, were thrombosis, 1.3 and 0.8; MCRCs, 0.6 and 0.7; embolism, 0.4 and 0.5; MB, 0.1 and 0.3; and ICH, 0.1 in both cohorts. Patients with cancer at baseline had significantly higher IRs for CRBSIs and thrombosis than non-cancer patients. CVC or HD catheter-related complications were most frequently seen in patients 16 years or younger. The risk of catheter-related complications is highest during the first 90 days of catheter placement in patients with CVCs and HD catheters and in younger patients (≤16 years of age) with HD catheters. Data provided in this study can be applied

  17. Intramuscular ketamine to facilitate pediatric central vascular access.

    Science.gov (United States)

    Denmark, T Kent; Hargrove, Jenny R; Brown, Lance

    2004-07-01

    Obtaining prompt vascular access in young children presenting to the emergency department (ED) is frequently both necessary and technically challenging. The objective of our study was to describe our experience using intramuscular (IM) ketamine to facilitate the placement of central venous catheters in children presenting to our ED needing vascular access in a timely fashion. We performed a retrospective medical record review of all pediatric patients central venous catheter facilitated by the use of IM ketamine. Eleven children met our inclusion criteria. Most of the children were young and medically complicated. The children ranged in age from 6 months to 8 years. The only complication identified was vomiting experienced by an 8-year-old boy. Emergency physicians successfully obtained central venous access in all subjects in the case series. The use of IM ketamine to facilitate the placement of central venous catheters in children who do not have peripheral venous access appears to be helpful. Emergency physicians may find it useful to be familiar with this use of IM ketamine.

  18. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: a study protocol

    Directory of Open Access Journals (Sweden)

    Hagen Sander M

    2011-12-01

    Full Text Available Abstract Background Peritoneal dialysis (PD is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as in- and outflow obstruction, peritonitis, exit-site infections, leakage and migration, can lead to catheter removal and loss of peritoneal access. Currently, different surgical techniques are in practice for PD-catheter placement. The type of insertion technique used may greatly influence the occurrence of complications. In the literature, up to 35% catheter failure has been described when using the open technique and only 13% for the laparoscopic technique. However, a well-designed randomized controlled trial is lacking. Methods/Design The LOCI-trial is a multi-center randomized controlled, single-blind trial (pilot. The study compares the laparoscopic with the open technique for PD catheter insertion. The primary objective is to determine the optimum placement technique in order to minimize the incidence of catheter malfunction at 6 weeks postoperatively. Secondary objectives are to determine the best approach to optimize catheter function and to study the quality of life at 6 months postoperatively comparing the two operative techniques. Discussion This study will generate evidence on any benefits of laparoscopic versus open PD catheter insertion. Trial registration Dutch Trial Register NTR2878

  19. Hemodialysis Access Usage Patterns in the Incident Dialysis Year and Associated Catheter-Related Complications

    Science.gov (United States)

    Xue, Hui; Ix, Joachim H.; Wang, Weiling; Brunelli, Steven M.; Lazarus, Michael; Hakim, Raymond; Lacson, Eduardo

    2012-01-01

    Background Hemodialysis(HD) access is considered a critical and actionable determinant of morbidity, with a growing literature suggesting that initial HD access type is an important marker of long term outcomes. Accordingly, we examined HD access during the incident dialysis period, focusing on infection risk and successful fistula creation over the first dialysis year. Study Design Longitudinal cohort Setting & Participants All United States adults admitted to Fresenius Medical Care North America facilities within 15 days of first maintenance dialysis session between January 1 and December 31, 2007. Predictor Vascular access type at HD initiation Outcomes Vascular access type at 90 days and at the end of the first year on HD, bloodstream infection within the first year by access type, and catheter complication rate. Results Amongst the 25,003 incident dialysis patients studied, 19,622(78.5%) initiated dialysis with a catheter, 4,151(16.6%) with a fistula, and 1,230(4.9%) with a graft. At 90 days, 14,105(69.7%) had a catheter, 4432(21.9%) patients had a fistula, and 1705(8.4%) had a graft. Functioning fistulas and grafts at dialysis initiation had first year failure rates of 10% and 15%, respectively. Grafts were seldom replaced by fistulas (3%), while 7,064 (47.6%) of all patients who initiated with a catheter alone still had only a catheter at 1 year. Overall, 3,327 (13.3%) patients had at least one positive blood culture during follow-up, with the risk being similar between fistula and graft groups, but approximately 3-fold higher in patients with a catheter (p<0.001 for either comparison). Nearly one in three catheters (32.5%) will require TPA use by median time of 41 days, with 59% requiring more than one TPA administration. Limitations Potential underestimation of bacteremia because follow-up blood culture results did not include samples sent to local laboratories. Conclusions Among a large and representative population of incident US dialysis patients

  20. Ablation of lumbar sympathetic ganglia by absolute ethanol injection and paravertebral catheter placement under CT guidance: evaluation of the efficacy

    International Nuclear Information System (INIS)

    Xu Hua; Xiong Yuanchang; Shao Chengwei; Zuo Changjing; Sheng Jing; Tian Jianming

    2009-01-01

    Objective: To evaluate the ablation of lumbar sympathetic ganglia by using single injection of absolute ethanol and retaining a paravertebral catheter under CT guidance for the treatment of lower extremity ischemia. Methods: Single absolute ethanol injection of L2 sympathetic ganglia was done in 25 cases (group B), single absolute ethanol injection of L2 sympathetic ganglia together with placement of a paravertebral catheter at L3 was carried out in 23 cases (group BT). All the procedures were performed under CT guidance. Three days after the procedure, the pain severity of the lower limbs was evaluated based on VAS method. If the patient in group BT still had a VAS score ≥4 on the third day, 3 ml of 1% lidocaine was infected via the retained catheter in the prone position. If VAS score became ≤3 at 5 min after the injection, additional 5 ml of ethanol was given through the catheter. The pain severity was evaluated again one week later. VAS score, analgesic dose and temperature of lower limbs were recorded. Results: One week after the procedure the excellent rate and effective rate for group B were 32% and 80% respectively, while for group BT were 60.9% and 95.7% respectively, with a significant difference between two groups (P<0.01). Conclusion: For the ablation of lumbar sympathetic ganglia the combination of single absolute ethanol injection with paravertebral catheter placement under CT guidance is superior to the single absolute ethanol injection. This technique is more individual with better results and is more likely to be accepted by the patients. (authors)

  1. C-arm Cone Beam Computed Tomographic Needle Path Overlay for Fluoroscopic-Guided Placement of Translumbar Central Venous Catheters

    International Nuclear Information System (INIS)

    Tam, Alda; Mohamed, Ashraf; Pfister, Marcus; Rohm, Esther; Wallace, Michael J.

    2009-01-01

    C-arm cone beam computed tomography is an advanced 3D imaging technology that is currently available on state-of-the-art flat-panel-based angiography systems. The overlay of cross-sectional imaging information can now be integrated with real-time fluoroscopy. This overlay technology was used to guide the placement of three percutaneous translumbar inferior vena cava catheters.

  2. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    Science.gov (United States)

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (pPhlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  3. Radiologic placement of implantable chest ports in pediatric patients under sedation

    International Nuclear Information System (INIS)

    Shin, Tae Beom

    2003-01-01

    To evaluate the safety and efficacy of the radiologic placement of implantable chest ports under intravenous sedation in pediatric patients with malignancy. Between October 2001 and June 2002, 20 chest ports were placed in 19 pediatric patients [13 boys and six girls aged 1-11 (mean, 4.7) years] for the purpose of long-term chemotherapy. In three patients, tunneled central venous catheters had been removed because of catheter extration, infection, and tearing. Under intravenous sedation, the right internal jugular vein was used for access in 19 cases, and the left internal jugular vein in one. Venipucture was performed using a micropuncture needle with real-time ultrasound guidance. A port chamber was created at the infraclavicular fossa, and to prevent catheter kinking, a smooth-angled tunnel was created between the venipuncture site and the subcutaneous pocket. The catheter tip was positioned under fluoroscopy at the junction of the superior vena cava and right atrium. We observed technical success, complications arouse during and after the procedure, and duration of catheter use. Implantation of the port system was successful in all cases, though slight hematoma, treated with manual compression, occurred at a chamber pocket in one case. In addition, the port system was removed from one patient because of wound infection leading to dehiscence and catheter malpositiong. A new port system was implanted through the left internal jugular vein. The median period during which catheter use was followed up was 118 (range, 18-274) days. For long-term chemotherapy in pediatric patients with malignancy, radiologic placement of an implantable chest port under intravenous sedation shows a high technical success rate, with few complications. This method may thus be used instead of surgical port placement

  4. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  5. Effective flow performances and dialysis doses delivered with permanent catheters: a 24-month comparative study of permanent catheters versus arterio-venous vascular accesses.

    Science.gov (United States)

    Canaud, Bernard; Leray-Moragues, Hélène; Kerkeni, Nadia; Bosc, Jean-Yves; Martin, Katja

    2002-07-01

    Permanent venous catheters have emerged as a long-term vascular access option for renal replacement therapy in end-stage renal disease patients. The design and venous location of catheter devices bear intrinsic flow limitations that may negatively affect the adequacy of dialysis and the patient outcome. There is limited data comparing the long-term dialysis adequacy delivered with permanent catheters vs arterio-venous vascular accesses (AVA). To explore this problem, we conducted a prospective 24-month trial comparing the flow performances and dialysis dose (Kt/Vdp) deliveries of both access options in a group of 42 haemodialysis patients during two study phases. During the first 12 months the patients completed a treatment period by means of permanent dual silicone catheters (DualKT). Then they were transferred to an AVA (40 native arterio-venous fistulas and two PTFE grafts) and monitored for an additional 12-month period. Assessments of flow adequacy and dialysis quantification were performed monthly. Dialysis adequacy was achieved in all cases. No patient had to be transferred prematurely to the AVA because of catheter failure. Three catheters had to be replaced due to bacteraemia in three patients. The mean effective blood flow rates achieved were 316+/-3.5 ml/min and 340+/-3.3 ml/min with DualKT and AVA, respectively, for a pre-set machine blood flow of 348+/-2.2 ml/min. Recirculation rates evaluated with the 'slow blood flow' method were 8.6+/-0.6 and 12.1+/-0.8% for DualKT and AVA using mean values of the solute markers urea and creatinine. Due to the possibility of a comparison veno-venous vs arterio-venous blood circulation, a corrected arterio-venous access recirculation could be derived from the difference between the two, which was around 3%. The blood flow resistance of the DualKT was slightly higher than with AVA as indicated by venous pressure differences. Kt/Vdp delivered was 1.37+/-0.02 and 1.45+/-0.02 with DualKT and AVA access respectively. The

  6. Spinal canal extension of hyperalimentation catheter without neurologic sequela

    International Nuclear Information System (INIS)

    Glasier, M.; Arkansas Children's Hospital, Little Rock; Hassell, D.R.

    1989-01-01

    An attempt at placement of a left femoral vein hyperalimentation catheter resulted in entrance of the catheter into the spinal canal. Catheter location was documented by injections of nonionic contrast material into the catheter without neurologic sequellae. (orig.)

  7. Hollow mandrin facilitates external ventricular drainage placement.

    Science.gov (United States)

    Heese, O; Regelsberger, J; Kehler, U; Westphal, M

    2005-07-01

    Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening

  8. Innovative Approaches to Neuraxial Blockade in Children: The Introduction of Epidural Nerve Root Stimulation and Ultrasound Guidance for Epidural Catheter Placement

    Directory of Open Access Journals (Sweden)

    Ban CH Tsui

    2006-01-01

    Full Text Available Continuous epidural blockade remains the cornerstone of pediatric regional anesthesia. However, the risk of catastrophic trauma to the spinal cord when inserting direct thoracic and high lumbar epidural needles in anesthetized or heavily sedated pediatric patients is a concern. To reduce this risk, research has focused on low lumbar or caudal blocks (ie, avoiding the spinal cord and threading catheters from distal puncture sites in a cephalad direction. However, with conventional epidural techniques, including loss-of-resistance for localization of the needle, optimal catheter tip placement is difficult to assess because considerable distances are required during threading. Novel approaches include electrical epidural stimulation for physiological confirmation and segmental localization of epidural catheters, and ultrasound guidance for assessing related neuroanatomy and real-time observation of the needle puncture and, potentially, catheter advancement. The present article provides a brief and focused review of these two advances, and outlines recent clinical experiences relevant to pediatric epidural anesthesia.

  9. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    Science.gov (United States)

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access

  10. Missed signs of autonomic dysreflexia in a tetraplegic patient after incorrect placement of urethral Foley catheter: a case report.

    Science.gov (United States)

    Vaidyanathan, Subramanian; Soni, Bakul M; Oo, Tun; Hughes, Peter L; Singh, Gurpreet

    2014-01-01

    Autonomic dysreflexia is poorly recognised outside of spinal cord injury centres, and may result in adverse outcomes including mortality from delayed diagnosis and treatment. We present a spinal cord injury patient, who developed autonomic dysreflexia following incorrect placement of urethral Foley catheter. Health professionals failed to recognise signs and symptoms of autonomic dysreflexia as well as its significance in this tetraplegic patient. A tetraplegic patient started sweating profusely following insertion of a Foley catheter per urethra. The catheter was draining urine; there was no bypassing, no bleeding per urethra, and no haematuria. Patient's wife, who had been looking after her tetraplegic husband for more than forty years, told the health professionals that the catheter might have been placed incorrectly but her concerns were ignored. Ultrasound scan of urinary tract revealed no urinary calculi, no hydronephrosis. The balloon of Foley catheter was not seen in urinary bladder but this finding was not recognised by radiologist and spinal cord physician. Patient continued to sweat profusely; therefore, CT of pelvis was performed, but there was a delay of ten days. CT revealed the balloon of Foley catheter in the over-stretched prostate-membranous urethra; the tip of catheter was not located within the urinary bladder but was lying distal to bladder neck. Flexible cystoscopy was performed and Foley catheter was inserted into the bladder over a guide wire. The intensity of sweating decreased; noxious stimuli arising from traumatised urethra might take a long while to settle. Inserting a catheter in a tetraplegic patient should be carried out by a senior health professional, who is familiar with spasm of bladder neck which occurs frequently in tetraplegic patients. Facilities for urgent CT scan should be available to check the position of Foley catheter in spinal cord injury patients when a patient manifests signs and symptoms of autonomic dysreflexia

  11. Umbilical venous catheters placement evaluation on frontal radiogram: application of a simplified flow-chart for radiology residents.

    Science.gov (United States)

    Salerno, Sergio; Tudisca, Chiara; Murmura, Elena; Matranga, Domenica; La Tona, Giuseppe; Lo Re, Giuseppe; Lo Casto, Antonio

    2017-05-01

    Umbilical Venous Catheter (UVC) are commonly used in neonatal period; they can be not correctly positioned and could be associated with complications. The purpose of this article is to suggest a flow-chart to evaluate the placement of UVC, testing it in young radiologists-in-training. We developed a simple flow-chart to asses, steps by step, UVC placement considering its course and tip location (ideally placed in the atriocaval junction). We tested the flow-chart impact asking to 20 residents to evaluate the placement of 10 UVC before and after they familiarized with the flow-chart and the anatomical findings of a newborn. The agreement among the 20 students was evaluated too. The number of correct characterizations was different due to the administration of the flow-chart. One hundred and six correct UVC assessments at the beginning switched to 196 after the administration of the flow-chart (p = 0.0001). The observed agreement among the twenty radiology residents was statistically significant, both before (kappa = 0.41, p < 0.001) and after (kappa = 0.37, p < 0.001) the flow-chart administration. The developed flow-chart demonstrated to be useful in increasing residents performance in UVC placement assessment.

  12. Bilhemia: a fatal complication following percutaneous placement of a transhepatic inferior vena cava catheter in a child

    International Nuclear Information System (INIS)

    Sierre, Sergio; Lipsich, Jose; Questa, Horacio

    2007-01-01

    A transhepatic central venous catheter was implanted in a 2-year-old child with a history of multiple venous access procedures and superior and inferior vena cava thrombosis. After 2 weeks, inadvertent dislodgement of the catheter was complicated by a biloma. The biloma was percutaneously drained, but a biliary-venous fistula led to a rapidly progressive and fatal bilhemia. We report this case as an infrequent complication of transhepatic catheterization. (orig.)

  13. Outcome of tunneled infusion catheters inserted via the right internal jugular vein

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Do, Young Soo; Choo, Sung Wook; Yoo, Wi Kang; Choo, In Wook; Kim, Jae Hyung

    2003-01-01

    To assess the outcome of tunneled central venous catheter placement via the right internal jugular vein. Between June 2001 and May 2002, 670 consecutive Hickman catheters were placed in 654 patients via the right internal jugular vein. The procedural complications arising and follow-up data obtained from May to July 2002 were evaluated. The technical success rate for catheter placement was 99.9% (669/670). Procedural complications were limited to eight cases (1.2%), including three pneumothoraces, one early migration of the catheter, one clinically unimportant air embolism, one catheter injury, one catheter kinking and one primary malpositioning in the azygos vein. Catheter dwelling time ranged from 1 to 407 (mean 107.1) days. During the follow-up period, 416 catheter were removed for various reasons: treatment had ended (n=334), patients declined treatment or their drug regimen was changed (n=16), late complications arose (n=53), or other circumstances intervened (n=13). Late complications included 44 cases of catheter-related infection (6.6%), five of catheter migration (0.7%), two of catheter occlusion (0.3%), one of thrombophlebitis (0.15%), and one of catheter-related right atrial thrombosis (0.15%). Only one instance of symptomatic venous thrombosis or stenosis was noted, namely the one case of thrombophlebitis. Because the incidence of subsequent symptomatic venous thrombosis or stenosis is lower, the preferred route for tunneled central venous catheter placement is the right internal jugular vein

  14. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    International Nuclear Information System (INIS)

    Too, Chow Wei; Sayani, Raza; Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva; Teo, Terence K.

    2016-01-01

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  15. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    Energy Technology Data Exchange (ETDEWEB)

    Too, Chow Wei, E-mail: toochowwei@gmail.com [Singapore General Hospital (Singapore); Sayani, Raza [Aga Khan University Hospital (Pakistan); Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva [Singapore General Hospital (Singapore); Teo, Terence K. [Mount Elizabeth Novena Hospital (Singapore)

    2016-08-15

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  16. Placement of empty catheters for an HDR-emulating LDR prostate brachytherapy technique: comparison to standard intraoperative planning.

    Science.gov (United States)

    Niedermayr, Thomas R; Nguyen, Paul L; Murciano-Goroff, Yonina R; Kovtun, Konstantin A; Neubauer Sugar, Emily; Cail, Daniel W; O'Farrell, Desmond A; Hansen, Jorgen L; Cormack, Robert A; Buzurovic, Ivan; Wolfsberger, Luciant T; O'Leary, Michael P; Steele, Graeme S; Devlin, Philip M; Orio, Peter F

    2014-01-01

    We sought to determine whether placing empty catheters within the prostate and then inverse planning iodine-125 seed locations within those catheters (High Dose Rate-Emulating Low Dose Rate Prostate Brachytherapy [HELP] technique) would improve concordance between planned and achieved dosimetry compared with a standard intraoperative technique. We examined 30 consecutive low dose rate prostate cases performed by standard intraoperative technique of planning followed by needle placement/seed deposition and compared them to 30 consecutive low dose rate prostate cases performed by the HELP technique. The primary endpoint was concordance between planned percentage of the clinical target volume that receives at least 100% of the prescribed dose/dose that covers 90% of the volume of the clinical target volume (V100/D90) and the actual V100/D90 achieved at Postoperative Day 1. The HELP technique had superior concordance between the planned target dosimetry and what was actually achieved at Day 1 and Day 30. Specifically, target D90 at Day 1 was on average 33.7 Gy less than planned for the standard intraoperative technique but was only 10.5 Gy less than planned for the HELP technique (p 0.05). Placing empty needles first and optimizing the plan to the known positions of the needles resulted in improved concordance between the planned and the achieved dosimetry to the target, possibly because of elimination of errors in needle placement. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Emergency Department Catheter-Associated Urinary Tract Infection Prevention: Multisite Qualitative Study of Perceived Risks and Implemented Strategies.

    Science.gov (United States)

    Carter, Eileen J; Pallin, Daniel J; Mandel, Leslie; Sinnette, Corine; Schuur, Jeremiah D

    2016-02-01

    Existing knowledge of emergency department (ED) catheter-associated urinary tract infection (CAUTI) prevention is limited. We aimed to describe the motivations, perceived risks for CAUTI acquisition, and strategies used to address CAUTI risk among EDs that had existing CAUTI prevention programs. In this qualitative comparative case study, we enrolled early-adopting EDs, that is, those using criteria for urinary catheter placement and tracking the frequency of catheters placed in the ED. At 6 diverse facilities, we conducted 52 semistructured interviews and 9 focus groups with hospital and ED participants. All ED CAUTI programs originated from a hospitalwide focus on CAUTI prevention. Staff were motivated to address CAUTI because they believed program compliance improved patient care. ED CAUTI prevention was perceived to differ from CAUTI prevention in the inpatient setting. To identify areas of ED CAUTI prevention focus, programs examined ED workflow and identified 4 CAUTI risks: (1) inappropriate reasons for urinary catheter placement; (2) physicians' limited involvement in placement decisions; (3) patterns of urinary catheter overuse; and (4) poor insertion technique. Programs redesigned workflow to address risks by (1) requiring staff to specify the medical reason for catheter at the point of order entry and placement; (2) making physicians responsible for determining catheter use; (3) using catheter alternatives to address patterns of overuse; and (4) modifying urinary catheter insertion practices to ensure proper placement. Early-adopting EDs redesigned workflow to minimize catheter use and ensure proper insertion technique. Assessment of ED workflow is necessary to identify and modify local practices that may increase CAUTI risk.

  18. Access technique and its problems in parenteral nutrition - Guidelines on Parenteral Nutrition, Chapter 9.

    Science.gov (United States)

    Jauch, K W; Schregel, W; Stanga, Z; Bischoff, S C; Brass, P; Hartl, W; Muehlebach, S; Pscheidl, E; Thul, P; Volk, O

    2009-11-18

    Catheter type, access technique, and the catheter position should be selected considering to the anticipated duration of PN aiming at the lowest complication risks (infectious and non-infectious). Long-term (>7-10 days) parenteral nutrition (PN) requires central venous access whereas for PN 3 weeks subcutaneous tunnelled catheters or port systems are appropriate. CVC (central venous catheter) should be flushed with isotonic NaCl solution before and after PN application and during CVC occlusions. Strict indications are required for central venous access placement and the catheter should be removed as soon as possible if not required any more. Blood samples should not to be taken from the CVC. If catheter infection is suspected, peripheral blood-culture samples and culture samples from each catheter lumen should be taken simultaneously. Removal of the CVC should be carried out immediately if there are pronounced signs of local infection at the insertion site and/or clinical suspicion of catheter-induced sepsis. In case PN is indicated for a short period (max. 7-10 days), a peripheral venous access can be used if no hyperosmolar solutions (>800 mosm/L) or solutions with a high titration acidity or alkalinity are used. A peripheral venous catheter (PVC) can remain in situ for as long as it is clinically required unless there are signs of inflammation at the insertion site.

  19. Over-the-catheter precut to gain access to the biliary duct during ERCP rendezvous.

    Science.gov (United States)

    Manes, Gianpiero; Baratti, Cinzia; Ardizzone, Sandro; Ferla, Fabio; Spiropoulos, Jean; Corsi, Fabio; Foschi, Diego; Trabucchi, Emilio; Bianchi Porro, Gabriele

    2008-10-01

    Endoscopic retrograde cholangiopancreatography (ERCP) rendezvous during laparoscopic cholecystectomy is an efficient and safe method to treat cholecystocholedocholithiasis. Advancing a guidewire through the cystic duct into the duodenum and withdrawing it in the accessory channel of duodenoscope may be, however, laborious. Moreover, rendezvous performed in the typical manner needs the use of several costly accessories. We herein describe a simpler and cheaper method to gain access to the biliary duct at rendezvous. Twenty-four consecutive patients undergoing ERCP rendezvous during laparoscopic cholecystectomy were considered. A catheter was introduced in the cystic duct and advanced into the duodenum. Access to the bile duct was than achieved by means of a precut sphincterotomy performed over the catheter emerging from the papilla. Cannulation was successful in all but two patients, in whom ERCP was performed in the conventional manner. The only complication was a case of mild post-sphincterotomy bleeding. In comparison with the typical rendezvous technique our procedure allowed savings of about 250, since its performance only requires a catheter and a knife sphincterotome. Over-the-catheter precut during ERCP rendezvous is a feasible and safe method which avoids the need for the manipulation of several accessories and guidewires, and thus results in money and time savings.

  20. Radiologic placement of hemodialysis central venous catheters: a practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Schemmer, D.; Sadler, D.J.; Gray, R.R.; Saliken, J.C.; So, C.B. [Foothills Hospital, Dept. of Diagnostic Imaging, Calgary, Alberta (Canada)

    2001-04-01

    Typical indications for central venous catheters (CVCs) are hemodialysis (HD), apheresis, total parenteral nutrition, analgesia, chemotherapy, long-term antibiotic therapy and cases of difficult or absent peripheral venous access. One of the largest medical services requesting CVC insertion is nephrology for HD patients. Demographics dictate that the demand for CVCs will continue to grow over the next few decades, placing striking demands on interventional radiology departments. In our centre, interventional radiologists now place nearly all percutaneously inserted HD CVCs. Radiologists provide rapid access to CVC services with significantly fewer complications than CVCs placed by other clinicians. With the demand for CVC management increasing and available operating room time decreasing, many clinicians now refer CVC insertions to radiologists. As well, clinicians who ordinarily place their own lines often refer high-risk patients, such as those who are obese or uncooperative and those with burns or coagulopathy. Our experience, derived from over 7000 CVC insertions, manipulations and removals, has allowed us to continually progress and improve our techniques, many of which are summarized here. (author)

  1. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    International Nuclear Information System (INIS)

    Desai, Shamit S.; Konanur, Meghana; Foltz, Gretchen; Malaisrie, S. Chris; Resnick, Scott

    2016-01-01

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared and externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period

  2. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Shamit S., E-mail: shamit.desai@northwestern.edu [Northwestern Memorial Hospital, Department of Radiology (United States); Konanur, Meghana [Northwestern University Feinberg School of Medicine (United States); Foltz, Gretchen [Mallinckrodt Institute of Radiology at Washington University, Interventional Radiology (United States); Malaisrie, S. Chris [Northwestern Memorial Hospital, Department of Cardiothoracic Surgery (United States); Resnick, Scott, E-mail: sresnick@northwestern.edu [Northwestern University Feinberg School of Medicine, Department of Radiology, Interventional Radiology, Northwestern Memorial Hospital (United States)

    2016-03-15

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared and externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.

  3. Renal access in PNL under sonographic guidance: Do we really need to insert an open end ureteral catheter in dilated renal systems? A prospective randomized study.

    Science.gov (United States)

    Eryildirim, Bilal; Tuncer, Murat; Camur, Emre; Ustun, Fatih; Tarhan, Fatih; Sarica, Kemal

    2017-10-03

    To evaluate the true necessity of open end ureteral catheter insertion in patients with moderate to severe pelvicalyceal system dilation treated with percutaneous nephrolithotomy (PNL) under sonographic guidance. 50 cases treated with PNL under sonographic guidance in prone position for solitary obstructing renal stones were evaluated. Patients were randomly divided into two groups; Group 1: Patients in whom a open end ureteral catheter was inserted prior to the procedure; Group 2: Patients receiving no catheter before PNL. In addition to the duration of the procedure as a whole and also all relevant stages as well, radiation exposure time, hospitalization period, mean nephrostomy tube duration, mean drop in Hb levels and all intra and postoperative complications have been evaluated. Mean size of the stones was 308.5 ± 133.2 mm2. Mean total duration of the PNL procedure in cases with open end ureteral catheter was significantly longer than the other cases (p < 0.001). Evaluation of the outcomes of the PNL procedures revealed no statistically significant difference between two groups regarding the stone-free rates (86% vs 84%). Additionally, there was no significant difference with respect to the duration of nephrostomy tube, hospitalization period and secondary procedures needed, complication rates as well as the post-operative Hb drop levels in both groups (p = 0.6830). Our results indicate that the placement of an open end ureteral catheter prior to a PNL procedure performed under sonographic access may not be indicated in selected cases presenting with solitary obstructing renal pelvic and/or calyceal stones.

  4. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    Energy Technology Data Exchange (ETDEWEB)

    Kotsikoris, Ioannis, E-mail: gkotsikoris@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Zygomalas, Apollon, E-mail: azygomalas@upatras.gr [Department of General Surgery, University Hospital of Patras (Greece); Papas, Theofanis, E-mail: pfanis@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Maras, Dimitris, E-mail: dimmaras@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Pavlidis, Polyvios, E-mail: polpavlidis@yahoo.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Andrikopoulou, Maria, E-mail: madric@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Tsanis, Antonis, E-mail: atsanis@gmail.com [Department of Interventional Radiology, “Erythros Stauros” General Hospital (Greece); Alivizatos, Vasileios, E-mail: valiviz@hol.gr [Department of General Surgery and Artificial Nutrition Unit, “Agios Andreas” General Hospital of Patras (Greece); Bessias, Nikolaos, E-mail: bessias@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece)

    2012-09-15

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates.

  5. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    International Nuclear Information System (INIS)

    Kotsikoris, Ioannis; Zygomalas, Apollon; Papas, Theofanis; Maras, Dimitris; Pavlidis, Polyvios; Andrikopoulou, Maria; Tsanis, Antonis; Alivizatos, Vasileios; Bessias, Nikolaos

    2012-01-01

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates

  6. Access technique and its problems in parenteral nutrition – Guidelines on Parenteral Nutrition, Chapter 9

    Directory of Open Access Journals (Sweden)

    Bischoff, S. C.

    2009-11-01

    Full Text Available Catheter type, access technique, and the catheter position should be selected considering to the anticipated duration of PN aiming at the lowest complication risks (infectious and non-infectious. Long-term (>7–10 days parenteral nutrition (PN requires central venous access whereas for PN 3 weeks subcutaneous tunnelled catheters or port systems are appropriate. CVC (central venous catheter should be flushed with isotonic NaCl solution before and after PN application and during CVC occlusions. Strict indications are required for central venous access placement and the catheter should be removed as soon as possible if not required any more. Blood samples should not to be taken from the CVC. If catheter infection is suspected, peripheral blood-culture samples and culture samples from each catheter lumen should be taken simultaneously. Removal of the CVC should be carried out immediately if there are pronounced signs of local infection at the insertion site and/or clinical suspicion of catheter-induced sepsis. In case PN is indicated for a short period (max. 7–10 days, a peripheral venous access can be used if no hyperosmolar solutions (>800 mosm/L or solutions with a high titration acidity or alkalinity are used. A peripheral venous catheter (PVC can remain in situ for as long as it is clinically required unless there are signs of inflammation at the insertion site.

  7. Cerebral microdialysis methodology--evaluation of 20 kDa and 100 kDa catheters.

    Science.gov (United States)

    Hutchinson, P J; O'Connell, M T; Nortje, J; Smith, P; Al-Rawi, P G; Gupta, A K; Menon, D K; Pickard, J D

    2005-08-01

    Microdialysis monitoring of cerebral metabolism is now performed in several neuro-intensive care units. Conventional microdialysis utilizes CMA70 catheters with 20 kDa molecular weight cut-off membranes enabling the measurement of small molecules such as glucose, lactate, pyruvate and glutamate. The CMA71 100 kDa molecular weight cut-off microdialysis catheter has recently been introduced to allow detection of larger molecules such as cytokines. The objective of this study was to perform in vitro and in vivo testing of the CMA71 microdialysis catheter, comparing its performance with the CMA70. In vitro comparison studies of three of each catheter using reference analyte solutions, demonstrated equivalent recovery for glucose, lactate, pyruvate and glutamate (range 94-97% for CMA70 and 88-103% for CMA71). In vivo comparison involved intracranial placement of paired CMA70 and CMA71 catheters (through the same cranial access device) in six patients with severe traumatic brain injury. Both catheters were perfused with CNS Perfusion Fluid without dextran at 0.3 microl min-1 with hourly sampling and bedside analysis on a CMA600 microdialysis analyser. The two catheters yielded equivalent results for glucose, lactate, pyruvate, glutamate and lactate/pyruvate ratio. CMA71 microdialysis catheters can, therefore, be used for routine clinical monitoring of extracellular substances, as well as for their intended research role of larger molecular weight protein sampling.

  8. Vena cava filter placement via the antecubital access: a report of 6 cases

    International Nuclear Information System (INIS)

    Yu Bo; Shi Weihao; He Qing; Wang Tieping; Wang Wei

    2008-01-01

    Objective: To study the methods and skill of vena cava filter placement via the antecubital access. Methods: Six patients with DVT (4 males and 2 females, mean age of 62) underwent vena cava filter placement via the antecubital access in Huashan Hospital from Oct. 2004 to May. 2006. The right basilic vein was punctured with the use of micropuncture technique. SNF(Simon nitinol filter, Bard)was inserted through its carrier into the 90-cm-long sheath. The filter was then deployed with a standard fashion in the IVC, 5 cm inferior to the renal vein. Results: The filter was once placed successfully in all six patients within average time of 25 min without complications, but with good healing, exclusion of bleeding and no phlebitis. The position of filter was accurate without deviation and no occurrence of pulmonary embolism. Conclusions: vena cava filter placement via antecubital access is easy, minimal invasive, no need of lying in bed postoperatively. It is beneficial for DVT patients as an alternative for the contra-indication to femoral venous access. (authors)

  9. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    by ultrasound dilution was determined within three days of the procedure. The methods were compared using regression analysis and tested for systematic bias. Results: Failure to position the thermodilutional catheter correctly was observed in 8 out of 46 (17%) pre-intervention measurements. Post-intervention......Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...

  10. Intracorporeal knotting of a femoral nerve catheter

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2015-01-01

    Full Text Available Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

  11. Risk factors for peritoneal dialysis catheter failure in children ...

    African Journals Online (AJOL)

    Background Peritoneal dialysis catheter (PDC) failure still remains a common clinical problem in pediatric patients despite advancements in catheter placement and dialysis techniques. Our aim was to determine the risk factors that may lead to PDC failure, especially those factors that could be potentially modified to ...

  12. Venous access: options, approaches and issues

    International Nuclear Information System (INIS)

    Asch, M.R.

    2001-01-01

    Venous access is an essential part of medical practice. It is needed to obtain blood samples to make the diagnosis and to administer fluids or medicines as part of treatment. Although relatively new in the history of medicine, the placement and maintenance of the various venous access devices now occupies a significant portion of many vascular and interventional radiology practices. Thus, it is important to have a thorough understanding of these devices and their uses. The first long-term venous access devices were used in 1973. These were placed via a surgical cut-down on the subclavian vein. In 1982, the first subcutaneous implantable ports were described. These procedures were initially performed by surgeons, but over the last 5-10 years, both the insertion and management of these devices has shifted to interventional radiologists. Peripherally inserted central catheter (PICC) lines have almost completely supplanted the use of standard central lines (Fig. 1). A number of factors have facilitated this - namely, ready and less expensive room access, outpatient procedure and radiologists' accessibility and familiarity with image-guidance procedures and catheters and guide wires. (author)

  13. Ultrasound Pulsed-Wave Doppler Detects an Intrathecal Location of an Epidural Catheter Tip: A Case Report.

    Science.gov (United States)

    Elsharkawy, Hesham; Saasouh, Wael; Patel, Bimal; Babazade, Rovnat

    2018-04-01

    Currently, no gold standard method exists for localization of an epidural catheter after placement. The technique described in this report uses pulsed-wave Doppler (PWD) ultrasound to identify intrathecal location of an epidural catheter. A thoracic epidural catheter was inserted after multiple trials with inconclusive aspiration and test dose. Ultrasound PWD confirmed no flow in the epidural space and positive flow in the intrathecal space. A fluid aspirate was positive for glucose, reconfirming intrathecal placement. PWD is a potential tool that can be used to locate the tip of an epidural catheter.

  14. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  15. A Study of Use of “PORT” Catheter in Patients with Cancer: A Single-Center Experience

    Directory of Open Access Journals (Sweden)

    Irappa Madabhavi

    2017-02-01

    Full Text Available Background: Effective and reliable venous access is one of the cornerstones of modern medical therapy in oncology. Materials and methods: This is a prospective observational study, which collected data of patients who require “PORT” catheter insertion for any cancer, at a tertiary care oncology hospital in Ahmadabad, Gujarat, India, during a 2-year period. Aims and objectives: The main objective of this study was to study the various complications and outcomes related to “PORT” catheters. Results: “PORT” catheter was inserted in 100 patients and was most commonly used in solid malignancies (n = 86, 86%, followed by hematologic malignancies (n = 14, 14%. Among the solid malignancies, breast cancer (38, 38% was the most common underlying disease, whereas among the hematologic malignancies, acute lymphoblastic leukemia (6, 6% was the most common underlying disease for “PORT” catheter insertion. Chemotherapy was started on the first day of “PORT” catheter in 74% of patients in the “PORT” study group. The various complications developed in the “PORT” study group in the descending order are as follows: 4 patients (4% developed early infection (⩽30 days after “PORT” placement, 4 (4% late infection (⩾30 days after “PORT” placement, 4 (4% bloodstream infection, 2 (2% local skin infection at the “PORT” insertion site, 2 (2% dislodgment of the “PORT” catheter, 2 (2% fracture of the “PORT” catheter, and 1 recurrent pleural effusion. One patient (1% developed thrombosis as the complication of “PORT” catheter insertion. Conclusions: The most disturbing aspect of treatment for a patient with cancer is multiple painful venipunctures made for administration of cytotoxic agents, antibiotics, blood products, and nutritional supplements. The focus of this prospective observational research is to study the various underlying diseases for which “PORT” catheter is needed in different solid and hematologic

  16. [Peripheral intravenous catheter-related phlebitis].

    Science.gov (United States)

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  17. Excellence, Equity, and Access: Educators' Perceptions of Students in Open Access Advanced Placement Courses

    Science.gov (United States)

    King, Justyna Plichta

    2010-01-01

    This dissertation examines educators' perceptions regarding open access Advanced Placement (AP) program courses and their impact on non-traditional AP students in one suburban school district. The data were collected during the 2009-2010 school year through a 15-item Likert scale (and one open-ended item) survey which was disseminated during…

  18. Impact of Multislice CT Angiography on Planning of Radiological Catheter Placement for Hepatic Arterial Infusion Chemotherapy

    International Nuclear Information System (INIS)

    Sone, Miyuki; Kato, Kenichi; Hirose, Atsuo; Nakasato, Tatsuhiko; Tomabechi, Makiko; Ehara, Shigeru; Hanari, Takao

    2008-01-01

    The objective of this study was to assess prospectively the role of multislice CT angiography (MSCTA) on planning of radiological catheter placement for hepatic arterial infusion chemotherapy (HAIC). Forty-six patients with malignant liver tumors planned for HAIC were included. In each patient, both MSCTA and intra-arterial digital subtraction angiography (DSA) were performed, except one patient who did not undergo DSA. Comparison of MSCTA and DSA images was performed for the remaining 45 patients. Detectability of anatomical variants of the hepatic artery, course of the celiac trunk, visualization scores of arterial branches and interobserver agreement, presence of arterial stenosis, and technical outcome were evaluated. Anatomical variations of the hepatic artery were detected in 19 of 45 patients (42%) on both modalities. The course of the celiac trunk was different in 12 patients. The visualization scores of celiac arterial branches on MSCTA/DSA were 3.0 ± 0/2.9 ± 0.2 in the celiac trunk, 3.0 ± 0/2.9 ± 0.3 in the common hepatic artery, 2.9 ± 0.2/2.9 ± 0.3 in the proper hepatic artery, 2.9 ± 0.3/2.9 ± 0.4 in the right hepatic artery, 2.8 ± 0.4/2.9 ± 0.4 in the left hepatic artery, 2.9 ± 0.2/2.9 ± 0.3 in the gastroduodenal artery, 2.1 ± 0.8/2.2 ± 0.9 in the right gastric artery, and 2.7 ± 0.8/2.6 ± 0.8 in the left gastric artery. No statistically significant differences exist between the two modalities. Interobserver agreement for MSCTA was equivalent to that for DSA. Two patients showed stenosis of the celiac trunk on both modalities. Based on these imaging findings, technical success was accomplished in all patients. In conclusion, MSCTA is accurate in assessing arterial anatomy and abnormalities. MSCTA can provide adequate information for planning of radiological catheter placement for HAIC

  19. It all unraveled from there: case report of a central venous catheter guidewire unraveling.

    Science.gov (United States)

    Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc

    2014-12-01

    Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Role of regional anesthesia for placement of peritoneal dialysis catheter under ultrasound guidance: Our experience with 52 end-stage renal disease patients

    Directory of Open Access Journals (Sweden)

    Smaranjit Chatterjee

    2015-01-01

    Full Text Available Aim: The number of patients with end-stage renal disease (ESRD has shown a consistent rise in India in recent years. Continuous ambulatory peritoneal dialysis (CAPD remains one of the safe and effective forms of treatment. In this study, we have tried to assess the effectiveness of field block technique for analgesia during catheter placement surgery until 24 h postoperatively, also, if it can obviate the need for general anesthesia in these high-risk patients. Materials and Methods: We studied 52 ESRD patients from 2010 to 2012 who were posted for CAPD catheterization in the Department of Urology, Care Hospital, Hyderabad, India. Under ultrasound guidance, "unilateral posterior" and "unilateral subcostal" transversus abdominis plane block anesthesia were given for the placement of CAPD catheter. Patient′s intra-operative pain and post-operative pain were recorded with visual analog scores (VAS and analyzed. Results: All patients in our study belonged to American Society of Anesthesiologists category 2 or 3 with multiple co-morbidities. 41 out of 52 patients required no supplemental analgesia during the procedure; 8 patients needed additional infiltration of local anesthetic during skin incisions. Three patients required supplemental analgesia and were considered as failure. A VAS of two was noted in 30 patients and 1 in 19 Patients. No Patient had significant pain 24 h post operatively. No local complication was noted in any patient. Conclusion: CAPD Catheterization under regional field block remains safe and effective options for ESRD patients.

  1. Peritoneal catheter fixation combined with straight upward tunnel and low implant position to prevent catheter malfunction.

    Science.gov (United States)

    Zhang, Qingyan; Jiang, Chunming; Zhu, Wei; Sun, Cheng; Xia, Yangyang; Tang, Tianfeng; Wan, Cheng; Shao, Qiuyuan; Liu, Jing; Jin, Bo; Zhang, Miao

    2018-03-01

    Catheter malfunction is the main reason for early peritoneal dialysis (PD) technique failure. This study aimed to evaluate the effect of a new surgery technique with catheter fixation to the lower abdominal wall combined with straight upward tunnel and low implant position in reducing catheter malfunction. Patients with end stage renal disease who received PD in our centre from January 2013 to December 2015 were involved in this study. They were randomly divided into three groups according to surgical technique: traditional open surgery group, modified open surgery group and modified open surgery with catheter fixation group. All patients were followed up for six months after surgery. Catheter- related complications were analyzed. A total of 152 patients were involved. Among them, 49 received traditional open surgery (TOS group), 49 received modified open surgery (MOS group), and 54 received modified open surgery with catheter fixation (MOS-F group). During follow-up, no patients (0%) in MOS-F group developed catheter malfunction which was significantly lower than that of the TOS group (0 vs 16.33%, P = 0.002). Although not statistically significant, the incidence of catheter malfunction was lower in MOS-F group than that in MOS group (0 vs 4.08%, P = 0.134). No significant difference was observed in the episodes of infection, bleeding, leakage, inflow or outflow pain, hernia and delayed wound healing among the three groups (all P > 0.05). Catheter fixation combined with straight upward tunnel and low implant position can effectively prevent catheter malfunction in PD catheter placement. © 2016 Asian Pacific Society of Nephrology.

  2. J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system

    International Nuclear Information System (INIS)

    Hama, Yukihiro; Kusano, Shoichi; Makita, Kohzoh

    2004-01-01

    The aim of this study was to verify the feasibility of using a J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system (RPCS). Twenty-five patients with various hepatic malignancies underwent percutaneous implantation of an RPCS through the left subclavian artery for regional chemotherapy. To successfully puncture the left subclavian artery, a J-tipped guidewire was used as a target with fluoroscopic guidance. Technical success and complication rates, and numbers of puncture failures, were retrospectively analyzed. Implantation of the RPCS was successful in all patients. Eight (32%) patients had minor complications and no patient had major complications. The number of puncture failures per patient was 0 to 1 (mean=0.32). The J-tipped guidewire is a safe and appropriate target for puncture of the subclavian artery in the placement of an RPCS. (orig.)

  3. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    Caridi, James G.; Hawkins, Irvin F.; Akins, E. William; Young, Ronald S.

    1997-01-01

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  4. Placing of tunneled central venous catheters prior to induction chemotherapy in children with acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Frydenberg, Morten

    2010-01-01

    BACKGROUND: Tunneled central venous catheters (CVCs) are inevitable in children with acute lymphoid leukemia (ALL). The aim of this study was to evaluate the risk of CVC-related complications in children with ALL in relation to timing of catheter placement and type of catheter. PROCEDURE: All...

  5. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    International Nuclear Information System (INIS)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T.; Akhan, Okan

    2011-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  6. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T. [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey); Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey)

    2011-11-15

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  7. A comparative study of two techniques (electrocardiogram- and landmark-guided for correct depth of the central venous catheter placement in paediatric patients undergoing elective cardiovascular surgery

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar Barnwal

    2016-01-01

    Full Text Available Background and Aims: The complications of central venous catheterisation can be minimized by ensuring catheter tip placement just above the superior vena cava-right atrium junction. We aimed to compare two methods, using an electrocardiogram (ECG or landmark as guides, for assessing correct depth of central venous catheter (CVC placement. Methods: In a prospective randomised study of sixty patients of <12 years of age, thirty patients each were allotted randomly to two groups (ECG and landmark. After induction, central venous catheterisation was performed by either of the two techniques and position of CVC tip was compared in post-operative chest X-ray with respect to carina. Unpaired t-test was used for quantitative data and Chi-square test was used for qualitative data. Results: In ECG group, positions of CVC tip were above carina in 12, at carina in 9 and below carina in 9 patients. In landmark group, the positions of CVC tips were above carina in 10, at carina in 4 and below carina in 16 patients. Mean distance of CVC tip in ECG group was 0.34 ± 0.23 cm and 0.66 ± 0.35 cm in landmark group (P = 0.0001. Complications occurred in one patient in ECG group and in nine patients in landmark group (P = 0.0056. Conclusion: Overall, landmark-guided technique was comparable with ECG technique. ECG-guided technique was more precise for CVC tip placement closer to carina. The incidence of complications was more in the landmark group.

  8. Placement of a Port Catheter Through Collateral Veins in a Patient with Central Venous Occlusion

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Streitparth, Florian; Gebauer, Bernhard; Benter, Thomas

    2010-01-01

    Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition when required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.

  9. [Delayed (tension) pneumothorax after placement of a central venous catheter].

    Science.gov (United States)

    Tan, E C; van der Vliet, J A

    1999-09-11

    Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.

  10. Endoscopic Ultrasound-Guided Perirectal Abscess Drainage without Drainage Catheter: A Case Series

    Directory of Open Access Journals (Sweden)

    Eun Kwang Choi

    2017-05-01

    Full Text Available A perirectal abscess is a relatively common disease entity that occurs as a postsurgical complication or as a result of various medical conditions. Endoscopic ultrasound (EUS-guided drainage was recently described as a promising alternative treatment. Previous reports have recommended placement of a drainage catheter through the anus for irrigation, which is inconvenient to the patient and carries a risk of accidental dislodgement. We report four cases of perirectal abscess that were successfully treated with only one or two 7 F double pigtail plastic stent placements and without a drainage catheter for irrigation.

  11. Intravenous catheter training system: computer-based education versus traditional learning methods.

    Science.gov (United States)

    Engum, Scott A; Jeffries, Pamela; Fisher, Lisa

    2003-07-01

    Virtual reality simulators allow trainees to practice techniques without consequences, reduce potential risk associated with training, minimize animal use, and help to develop standards and optimize procedures. Current intravenous (IV) catheter placement training methods utilize plastic arms, however, the lack of variability can diminish the educational stimulus for the student. This study compares the effectiveness of an interactive, multimedia, virtual reality computer IV catheter simulator with a traditional laboratory experience of teaching IV venipuncture skills to both nursing and medical students. A randomized, pretest-posttest experimental design was employed. A total of 163 participants, 70 baccalaureate nursing students and 93 third-year medical students beginning their fundamental skills training were recruited. The students ranged in age from 20 to 55 years (mean 25). Fifty-eight percent were female and 68% percent perceived themselves as having average computer skills (25% declaring excellence). The methods of IV catheter education compared included a traditional method of instruction involving a scripted self-study module which involved a 10-minute videotape, instructor demonstration, and hands-on-experience using plastic mannequin arms. The second method involved an interactive multimedia, commercially made computer catheter simulator program utilizing virtual reality (CathSim). The pretest scores were similar between the computer and the traditional laboratory group. There was a significant improvement in cognitive gains, student satisfaction, and documentation of the procedure with the traditional laboratory group compared with the computer catheter simulator group. Both groups were similar in their ability to demonstrate the skill correctly. CONCLUSIONS; This evaluation and assessment was an initial effort to assess new teaching methodologies related to intravenous catheter placement and their effects on student learning outcomes and behaviors

  12. Positioning of nasobiliary tube using magnet-loaded catheters.

    Science.gov (United States)

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko; White, Robert I.

    2008-01-01

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  14. Preliminary Results of Emergency Computed Tomography-Guided Ventricular Drain Placement-Precision for the Most Difficult Cases.

    Science.gov (United States)

    Nowacki, Andreas; Wagner, Franca; Söll, Nicole; Hakim, Arsany; Beck, Jürgen; Raabe, Andreas; Z'Graggen, Werner J

    2018-04-05

    External ventricular drainage (EVD) catheter placement is one of the most commonly performed neurosurgical procedures. The study's objective was to compare a computed tomography (CT) bolt scan-guided approach for the placement of EVDs with conventional landmark-based insertion. In this retrospective case-control study, we analyzed patients undergoing bolt-kit EVD catheter placement, either CT-guided or landmark-based, between 2013 and 2016. The CT bolt scan-guided approach was based on a dose-reduced CT scan after bolt fixation with immediate image reconstruction along the axis of the bolt to evaluate the putative insertion axis. If needed, angulation of the bolt was corrected and the procedure repeated before the catheter was inserted. Primary endpoint was the accuracy of insertion. Secondary endpoints were the overall number of attempts, duration of intervention, complication rates, and cumulative radiation dose. In total, 34 patients were included in the final analysis. In the group undergoing CT-guided placement, the average ventricle width was significantly smaller (P = 0.04) and average midline shift significantly more pronounced (P = 0.01). CT-guided placement resulted in correct positioning of the catheter in the ipsilateral frontal horn in all 100% of the cases compared with landmark-guided insertion (63%; P = 0.01). Application of the CT-guided approach increased the number of total CT scans (3.6 ± 1.9) and the overall radiation dose (3.34 ± 1.61 mSv) compared with the freehand insertion group (1.84 ± 2.0 mSv and 1.55 ± 1.66 mSv). No differences were found for the other secondary outcome parameters. CT-guided bolt-kit EVD catheter placement is feasible and accurate in the most difficult cases. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Impact of quality management monitoring and intervention on central venous catheter dysfunction in the outpatient chemotherapy infusion setting.

    Science.gov (United States)

    Bansal, Anu; Binkert, Christoph A; Robinson, Malcolm K; Shulman, Lawrence N; Pellerin, Linda; Davison, Brian

    2008-08-01

    To assess the utility of maintaining and analyzing a quality-management database while investigating a subjectively perceived increase in the incidence of tunneled catheter and port dysfunction in a cohort of oncology outpatients. All 152 patients undergoing lytic therapy (2-4 mg alteplase) of a malfunctioning indwelling central venous catheter (CVC) from January through June 2004 at a single cancer center in the United States were included in a quality-management database. Patients were categorized by time to device failure and the initial method of catheter placement (surgery vs interventional radiology). Data were analyzed after 3 months, and areas of possible improvement were identified and acted upon. Three months of follow-up data were then collected and similarly analyzed. In a 6-month period, 152 patients treated for catheter malfunction received a total of 276 doses of lytic therapy. A 3-month interim analysis revealed a disproportionately high rate (34%) of early catheter malfunction (ECM; <30 days from placement). Postplacement radiographs demonstrated suboptimal catheter positioning in 67% of these patients, all of whom had surgical catheter placement. There was a 50% absolute decrease in the number of patients presenting with catheter malfunction in the period from April through June (P < .001). Evaluation of postplacement radiographs in these patients demonstrated a 50% decrease in the incidence of suboptimal positioning (P < .05). Suboptimal positioning was likely responsible for some, but not all, cases of ECM. Maintenance of a quality-management database is a relatively simple intervention that can have a clear and important impact on the quality and cost of patient care.

  16. Complications after percutaneous placement of totally implantable venous access ports in the forearm

    International Nuclear Information System (INIS)

    Goltz, J.P.; Petritsch, B.; Thurner, A.; Hahn, D.; Kickuth, R.

    2012-01-01

    This article focuses on radiological imaging of complications after interventional percutaneous insertion of totally implantable venous access ports (TIVAPs) which were placed in the forearm. Thus far most reviews have dealt with pectorally-placed TIVAPs. Compared with the pectoral approach, implantation in the forearm has been associated with certain complications owing to a longer route of the port catheter within a smaller vein, and owing to the route across the elbow joint, resulting in higher rates of catheter-associated thrombosis and possible mechanical complications. The purpose of this review is to describe the complications after implantation of TIVAPs in the forearm, and to make radiologists familiar with the key findings of the complications during radiological imaging, including colour-coded and compression Duplex ultrasound, computed tomography, and digital subtraction venography.

  17. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  18. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    Science.gov (United States)

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  19. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  20. A clever technique for placement of a urinary catheter over a wire

    Directory of Open Access Journals (Sweden)

    Joel E Abbott

    2015-01-01

    Conclusion: Placing urinary catheters over a wire is standard practice for urologists, however, use of this technique gives the freedom of performing wire-guided catheterization in more situations than a council-tip allows. This technique facilitates successful transurethral catheterization over wire in the setting of DUC for all catheter types and styles aiding in urologic management of patients at a cost benefit to the health care system.

  1. Ultrasound-Guided Peripheral Intravenous Access in the Emergency Department: Patient-Centered Survey

    Directory of Open Access Journals (Sweden)

    Keith Boniface

    2011-05-01

    Full Text Available Introduction: To assess characteristics, satisfaction, and disposition of emergency department (ED patients who successfully received ultrasound (US-guided peripheral intravenous (IV access. Methods: This is a prospective observational study among ED patients who successfully received US-guided peripheral IV access by ED technicians. Nineteen ED technicians were taught to use US guidance to obtain IV access. Training sessions consisted of didactic instruction and hands-on practice. The US guidance for IV access was limited to patients with difficult access. After successfully receiving an US-guided peripheral IV, patients were approached by research assistants who administered a 10-question survey. Disposition information was collected after the conclusion of the ED visit by accessing patients’ electronic medical record. Results: In total, 146 surveys were completed in patients successfully receiving US-guided IVs. Patients reported an average satisfaction with the procedure of 9.2 of 10. Forty-two percent of patients had a body mass index (BMI of greater than 30, and 17.8% had a BMI of more than 35. Sixty-two percent reported a history of central venous catheter placement. This patient population averaged 3 ED visits per year in the past year. Fifty-three percent of the patients were admitted. Conclusion: Patients requiring US-guided IVs in our ED are discharged home at the conclusion of their ED visit about half of the time. These patients reported high rates of both difficult IV access and central venous catheter placement in the past. Patient satisfaction with US-guided IVs was very high. These data support the continued use of US-guided peripheral IVs in this patient population. [West J Emerg Med. 2011;12(4:475–477.

  2. Life-threatening urethral hemorrhage after placement of a Foley catheter in a patient with uroseptic disseminated intravascular coagulation due to chronic urinary retention induced by untreated benign prostatic hyperplasia.

    Science.gov (United States)

    Ikegami, Yukihiro; Yoshida, Keisuke; Imaizumi, Tsuyoshi; Isosu, Tsuyoshi; Kurosawa, Shin; Murakawa, Masahiro

    2016-10-01

    A 77-year-old man with severe septic disseminated intravascular coagulation following urinary infection was transported to our hospital. He had developed urinary retention induced by untreated prostatic hyperplasia. Immediate drainage with a Foley catheter was successfully carried out, but the hematuria progressed to life-threatening hemorrhage. Complete hemostasis was impossible by surgical treatment because the tissue around the prostatic urethra was very fragile and hemorrhagic. Organized treatments (continuous hemodiafiltration combined with polymyxin-B immobilized fiber column hemoperfusion and systemic treatment with antibiotics and coagulation factors) were commenced soon after the operation. The patient eventually recovered from the septic disseminated intravascular coagulation. This case report illustrates the risk of placement of Foley catheters in patients with severe septic disseminated intravascular coagulation.

  3. Tricuspid valve endocarditis following central venous cannulation: The increasing problem of catheter related infection

    Directory of Open Access Journals (Sweden)

    Suresh Babu Kale

    2013-01-01

    Full Text Available A central venous catheter (CVC is inserted for measurement of haemodynamic variables, delivery of nutritional supplements and drugs and access for haemodialysis and haemofiltration. Catheterization and maintenance are common practices and there is more to the technique than routine placement as evident when a procedure-related complication occurs. More than 15% of the patients who receive CVC placement have some complications and infectious endocarditis involving the tricuspid valve is a rare and serious complication with high morbidity and mortality. Overenthusiastic and deep insertion of the guide wire and forceful injection through the CVC may lead to injury of the tricuspid valve and predispose to bacterial deposition and endocarditis. We report a case of tricuspid valve endocarditis, probably secondary to injury of the anterior tricuspid leaflet by the guide wire or the CVC that required open heart surgery with vegetectomy and repair of the tricuspid valve.

  4. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    Science.gov (United States)

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  5. CATHETER DURATION AND THE RISK OF SEPSIS IN PREMATURE BABIES WITH UMBILICAL VEIN CATHETERS

    Directory of Open Access Journals (Sweden)

    Hartojo Hartojo

    2012-01-01

    Full Text Available Umbilical catheters are frequently required in the management of severely ill premature babies. The risk of complications may increase with duration of UVC use. Objective: To determine whether the risk of central line-associated bloodstream infections (CLA-BSIs and sepsis remained constant over the duration of umbilical vein catheters (UVCs in high-risk premature neonates. Methods:retrospective analysis. The data were collected from the medical record of high risk premature neonates who had a UVC placed in neonatal care unit of Husada Utama Hospital between April 1st 2008 to April 30th 2011 with purposive sampling. Catheter duration was observed before and after 14 days on placement. Blood and UVC culture was performed to establish the risk of CLA-BSIs and sepsis. Chi-square and logistic regression analysis were performed in the laboratorium data. Result: A total 44 high risk premature babies with UVCs were enrolled (sepsis group: n = 23 and non sepsis group: n = 21. Baseline demographics were similar between the groups. 15 babies in sepsis group have UVCs duration > 14 days, and 8 babies have UVCs 14 days show blood culture performance in 11 babies with positive evidence, UVCs culture performance is negative in 18 babies (p = 0.456. Burkholderia cepacia and Klebsiella pneumonia mostly appeared in blood culture performance. 25% of UVC culture performance shows Pseudomonas aeroginosa. Conclusions: The catheter duration have no significant difference in risk of sepsis in premature babies with Umbilical Vein Catheters.

  6. Urethral catheterization facilitates preradiation fiducial marker placement in postprostatectomy patients.

    Science.gov (United States)

    Williams, Christopher; Costa, Joseph; Mandia, Stephen; Henderson, Randal; Marino, Robert; Mendenhall, Nancy

    2012-05-01

    Surgical absence of the prostate can make placement of fiducial markers difficult, because anatomic landmarks are distorted and there is a paucity of substantial tissue to hold fast the markers. We describe a method for improving the accuracy of fiducial marker placement for the purpose of salvage or adjuvant external beam radiation therapy for prostate cancer in patients who have undergone radical prostatectomy. To assist with identification of the urethrovesical junction and to facilitate placement of the markers, a Foley catheter was placed and the balloon was inflated. Gentle traction on the catheter seated the balloon at the bladder neck to echographically define the anatomy of the urethrovesical junction. Next, a rectal ultrasound probe was inserted into the rectum, allowing visualization of the region of the urethrovesical junction. Fiducial markers were then placed bilaterally in the detrusor muscle at the bladder neck or in the periurethral tissue using the applicator needle. The treating radiation oncologist verified that marker placement was suitable for assisting with radiation therapy in all cases. Preradiation pelvic imaging verified that markers were not in the bladder or urethral lumen, and there were no patient complaints of voiding out the markers with urination.

  7. The Impact of Tunneled Catheters for Ascites and Peritoneal Carcinomatosis on Patient Rehospitalizations

    International Nuclear Information System (INIS)

    Qu, Chuanxing; Xing, Minzhi; Ghodadra, Anish; McCluskey, Kevin M.; Santos, Ernesto; Kim, Hyun S.

    2016-01-01

    PurposeThe aim of the study is to assess patient outcomes, complications, impact on rehospitalizations, and healthcare costs in patients with malignant ascites treated with tunneled catheters.Materials and MethodsA total of 84 patients with malignant ascites (mean age, 60 years) were treated with tunneled catheters. Patients with peritoneal carcinomatosis and malignant ascites treated with tunneled drain catheter placement over a 3-year period were studied. Overall survival from the time of ascites and catheter placement were stratified by primary cancer and analyzed using the Kaplan–Meier method. Complications were graded by the Common Terminology Criteria for Adverse Events v3.0 (CTCAE). The differences between pre- and post-catheter admissions, hospitalizations, and Emergency Department (ED) visits, as well as related inpatient expenses were compared using paired t tests.ResultsThere were no significant differences in gender, age, or race between different primary cancer subgroups. One patient (1 %) developed bleeding (CTCAE-2). Four patients (5 %) developed local cellulitis (CTCAE-2). Three patients (4 %) had prolonged hospital stay (between 7 and 10 days) to manage ascites-related complications such as abdominal distention, discomfort, or pain. Comparison between pre- and post-catheter hospitalizations showed significantly lower admissions (−1.4/month, p < 0.001), hospital stays (−4.2/month, p = 0.003), and ED visits (−0.9/month, p = 0.002). The pre- and post-catheter treatment health care cost was estimated using MS-DRG IPPS payment system and it demonstrated significant cost savings from decreased inpatient admissions in post-treatment period (−$9535/month, p < 0.001).ConclusionsTunneled catheter treatment of malignant ascites is safe, feasible, well tolerated, and cost effective. Tunneled catheter treatment may play an important role in improving patients’ quality of life and outcomes while controlling health care expenditures.

  8. The Impact of Tunneled Catheters for Ascites and Peritoneal Carcinomatosis on Patient Rehospitalizations

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Chuanxing [University of Pittsburgh School of Medicine, Division of Interventional Radiology, Department of Radiology (United States); Xing, Minzhi [Yale University School of Medicine, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, Yale Cancer Center (United States); Ghodadra, Anish; McCluskey, Kevin M.; Santos, Ernesto; Kim, Hyun S., E-mail: kevin.kim@yale.edu [University of Pittsburgh School of Medicine, Division of Interventional Radiology, Department of Radiology (United States)

    2016-05-15

    PurposeThe aim of the study is to assess patient outcomes, complications, impact on rehospitalizations, and healthcare costs in patients with malignant ascites treated with tunneled catheters.Materials and MethodsA total of 84 patients with malignant ascites (mean age, 60 years) were treated with tunneled catheters. Patients with peritoneal carcinomatosis and malignant ascites treated with tunneled drain catheter placement over a 3-year period were studied. Overall survival from the time of ascites and catheter placement were stratified by primary cancer and analyzed using the Kaplan–Meier method. Complications were graded by the Common Terminology Criteria for Adverse Events v3.0 (CTCAE). The differences between pre- and post-catheter admissions, hospitalizations, and Emergency Department (ED) visits, as well as related inpatient expenses were compared using paired t tests.ResultsThere were no significant differences in gender, age, or race between different primary cancer subgroups. One patient (1 %) developed bleeding (CTCAE-2). Four patients (5 %) developed local cellulitis (CTCAE-2). Three patients (4 %) had prolonged hospital stay (between 7 and 10 days) to manage ascites-related complications such as abdominal distention, discomfort, or pain. Comparison between pre- and post-catheter hospitalizations showed significantly lower admissions (−1.4/month, p < 0.001), hospital stays (−4.2/month, p = 0.003), and ED visits (−0.9/month, p = 0.002). The pre- and post-catheter treatment health care cost was estimated using MS-DRG IPPS payment system and it demonstrated significant cost savings from decreased inpatient admissions in post-treatment period (−$9535/month, p < 0.001).ConclusionsTunneled catheter treatment of malignant ascites is safe, feasible, well tolerated, and cost effective. Tunneled catheter treatment may play an important role in improving patients’ quality of life and outcomes while controlling health care expenditures.

  9. Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog.

    Science.gov (United States)

    Garcia-Pereira, Fernando L; Sanders, Robert; Shih, Andre C; Sonea, Ioana M; Hauptman, Joseph G

    2013-09-01

    To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. Prospective, experiment. Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia. © 2013 Association of Veterinary

  10. Total parenteral alimentation via indwelling umbilical catheters in the newborn period.

    Science.gov (United States)

    Hall, R T; Rhodes, P G

    1976-01-01

    Total parenteral alimentation (TPA) was delivered to 80 infants via indwelling umbilical artery and to 9 via indwelling umbilical venous catheters. The primary indication for catheter placement and maintenance was monitoring of arterial blood gases (umbilical venous catheter tip in left atrium) in a group of sick neonates requiring increased inspired oxygen or assisted ventilation. Results were compared with those from 23 infants who had tunnelled jugular catheters for a variety of chronic medical and surgical problems preventing gastric or intestinal feeding. A mean weight gain was achieved in both groups. Mortality and morbidity rates were similar in both groups. The most common complications were infection and thrombotic phenomena. Metabolic complications were few. It is concluded that infusing TPA solutions via indwelling umbilical catheters presents no greater risk than infusion via tunnelled jugular catheters, and provides a method for supplying adequate caloric intake for growth during the acute stage of illness. PMID:827978

  11. Choice of Hemodialysis Access in Older Adults: A Cost-Effectiveness Analysis.

    Science.gov (United States)

    Hall, Rasheeda K; Myers, Evan R; Rosas, Sylvia E; O'Hare, Ann M; Colón-Emeric, Cathleen S

    2017-06-07

    Although arteriovenous fistulas have been found to be the most cost-effective form of hemodialysis access, the relative benefits of placing an arteriovenous fistula versus an arteriovenous graft seem to be least certain for older adults and when placed preemptively. However, older adults' life expectancy is heterogeneous, and most patients do not undergo permanent access creation until after dialysis initiation. We evaluated cost-effectiveness of arteriovenous fistula placement after dialysis initiation in older adults as a function of age and life expectancy. Using a hypothetical cohort of patients on incident hemodialysis with central venous catheters, we constructed Markov models of three treatment options: ( 1 ) arteriovenous fistula placement, ( 2 ) arteriovenous graft placement, or ( 3 ) continued catheter use. Costs, utilities, and transitional probabilities were derived from existing literature. Probabilistic sensitivity analyses were performed by age group (65-69, 70-74, 75-79, 80-84, and 85-89 years old) and quartile of life expectancy. Costs, quality-adjusted life-months, and incremental cost-effectiveness ratios were evaluated for up to 5 years. The arteriovenous fistula option was cost effective compared with continued catheter use for all age and life expectancy groups, except for 85-89 year olds in the lowest life expectancy quartile. The arteriovenous fistula option was more cost effective than the arteriovenous graft option for all quartiles of life expectancy among the 65- to 69-year-old age group. For older age groups, differences in cost-effectiveness between the strategies were attenuated, and the arteriovenous fistula option tended to only be cost effective in patients with life expectancy >2 years. For groups for which the arteriovenous fistula option was not cost saving, the cost to gain one quality-adjusted life-month ranged from $2294 to $14,042. Among older adults, the cost-effectiveness of an arteriovenous fistula placed within the first

  12. Catheter ablation of epicardial ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Takumi Yamada, MD, PhD

    2014-08-01

    Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their

  13. [The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)].

    Science.gov (United States)

    Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro

    2014-01-01

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.

  14. CT guided transthoracic catheter drainage of intrapulmonary abscess.

    Science.gov (United States)

    Yunus, Mahira

    2009-10-01

    To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.

  15. Risk of extravasation after power injection of contrast media via the proximal port of multilumen central venous catheters. Case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Schummer, C.; Sakr, Y.; Reinhart, K. [Jena Univ. (Germany). Klinik fuer Anaestesiologie und Intensivtherapie; Steenbeck, J. [Jena Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Gugel, M. [Zentralklinik Bad Berka (Germany). Klinik fuer Anaesthesiologie und Intensivtherapie; Schummer, W. [SRH Zentralklinikum Suhl (Germany). Dept. of Anaesthesiology and Intensive Care Medicine

    2010-01-15

    Multilumen central venous catheters (CVCs) are not commonly used for power injection. However, in critically ill patients, CVCs - most of which do not have FDA approval for power injection - may be the only available venous access. The pitfalls of multilumen CVCs are illustrated by a case report of a patient in whom extravasation of intravenously administered contrast medium occurred after power injection in a triple-lumen CVC using the lumen with the port furthest from the catheter tip. The underlying mechanisms for the displacement of the initially correctly placed right subclavian CVC could include elevation of both arms of the obese patient or the power injection itself. The distances between port openings and catheter tips of various commercially available multilumen CVCs are assessed. We examine the possible caveats of ECG-guided CVC placement for optimal tip position, discuss technical difficulties related to power injection via CVCs, and review commonly used drugs that may cause extravasation injury. Knowledge of the distances between CVC port openings and the catheter tip are essential for safe intravasal administration of fluids. (orig.)

  16. Risk of extravasation after power injection of contrast media via the proximal port of multilumen central venous catheters. Case report and review of the literature

    International Nuclear Information System (INIS)

    Schummer, C.; Sakr, Y.; Reinhart, K.; Steenbeck, J.; Gugel, M.; Schummer, W.

    2010-01-01

    Multilumen central venous catheters (CVCs) are not commonly used for power injection. However, in critically ill patients, CVCs - most of which do not have FDA approval for power injection - may be the only available venous access. The pitfalls of multilumen CVCs are illustrated by a case report of a patient in whom extravasation of intravenously administered contrast medium occurred after power injection in a triple-lumen CVC using the lumen with the port furthest from the catheter tip. The underlying mechanisms for the displacement of the initially correctly placed right subclavian CVC could include elevation of both arms of the obese patient or the power injection itself. The distances between port openings and catheter tips of various commercially available multilumen CVCs are assessed. We examine the possible caveats of ECG-guided CVC placement for optimal tip position, discuss technical difficulties related to power injection via CVCs, and review commonly used drugs that may cause extravasation injury. Knowledge of the distances between CVC port openings and the catheter tip are essential for safe intravasal administration of fluids. (orig.)

  17. Suprapubic catheter care

    Science.gov (United States)

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  18. Transhepatic venous catheters for hemodialysis

    Directory of Open Access Journals (Sweden)

    Mohamed El Gharib

    2014-06-01

    Conclusion: Based on our findings, transhepatic hemodialysis catheters have proven to achieve good long-term functionality. A high level of maintenance is required to preserve patency, although this approach provides remarkably durable access for patients who have otherwise exhausted access options.

  19. Intra-operative placement of catheters for interstitial microwave-induced hyperthermia and iridium brachytherapy

    International Nuclear Information System (INIS)

    Coughlin, C.T.; Wong, T.Z.; Strohbehn, J.W.; Colacchio, T.A.; Belch, R.Z.; Sutton, J.E. Jr.; Douple, E.B.

    1984-01-01

    The authors have previously described a system for delivery of microwave-induced hyperthermia utilizing flexible coaxial cables that are modified to serve as microwave antennas. These small (--1.6mm o.d.) antennas ae introduced into 2mm o.d. nylon catheters implanted in the tumor. This system has been further modified for use in the treatment of surgically unresectible abdominal, pelvic, and head and neck tumors. The modifications are described that were used to treat two pelvic, one upper abdominal, and one base of tongue tumor. The nylon catheters are implanted during surgery. After a short recovery period, the microwave antennas are inserted and the tumor region is heated for --1hr. The antennas are removed, iridium-192 seeds are placed in the catheters, 2800 - 5000 rad (CGy) doses are delivered, followed by a 1hr hyperthermia treatment. The temperature distributions and future applications are discussed

  20. Is the Routine Check Nephrostogram Following Percutaneous Antegrade Ureteric Stent Placement Necessary?

    International Nuclear Information System (INIS)

    Soh, Keng Chuan; Tay, Kiang Hiong; Tan, Bien Soo; MM Htoo, Austin; HG Lo, Richard; Lin, Shueh En

    2008-01-01

    Our aim was to review our experience with percutaneous antegrade ureteric stent (PAUS) placement and to determine if the routinely conducted check nephrostogram on the day following ureteric stent placement was necessary. Retrospective review of patients who had undergone PAUS placement between January 2004 and December 2005 was performed. There were 83 subjects (36 males, 47 females), with a mean age of 59.9 years (range, 22-94 years). Average follow-up duration was 7.1 months (range, 1-24 months). The most common indications for PAUS placement were ureteric obstruction due to metastatic disease (n = 56) and urinary calculi (n = 34). Technical success was 93.2% (96/103 attempts), with no major immediate procedure-related complications or mortalities. The Bard 7Fr Urosoft DJ Stent was used in more than 95% of the cases. Eighty-one of 89 (91.0%) check nephrostograms demonstrated a patent ureteric stent with resultant safety catheter removal. Three check nephrostograms revealed distal stent migration requiring repositioning by a goose-snare, while five others showed stent occlusion necessitating permanent external drainage by nephrostomy drainage catheter reinsertion. Following PAUS placement, the serum creatinine level improved or stabilized in 82% of patients. The serum creatinine outcome difference between the groups with benign and malignant indications for PAUS placement was not statistically significant (p = 0.145) but resolution of hydronephrosis was significantly better (p = 0.008) in patients with benign indications. Percutaneous antegrade ureteric stent placement is a safe and effective means of relief for ureteric obstruction. The check nephrostogram following ureteric stent placement was unnecessary in the majority of patients

  1. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    Science.gov (United States)

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  2. Frequency of puncture holes in peritoneal dialysis catheters related to the beta cap adapter.

    Science.gov (United States)

    Ohashi, Yasushi; Kansal, Sheru; Schreiber, Martin

    2012-01-01

    Between November 2009 and September 2011, 12 patients (6 women, 6 men) undergoing continuous peritoneal dialysis (PD) or automated PD developed puncture-like holes in the PD catheter near the interface of the adapter with the superior aspect of the Silastic PD catheter The adapter is used to connect the PD catheter to the PD transfer set. Over the course of 23 months, the 12 patients presented to the PD unit with 19 separate instances of catheter holes, for an event rate of 0.23 holes per patient-year Data including socio-demographic information, PD modality, need for antibiotic treatment, event recurrence, infectious complications, and time from catheter placement were collected from patients whose catheters did and did not develop holes. We observed no differences between patients whose catheters developed holes and those whose catheters did not. The location of the individual holes suggested a relationship between the adapter and the catheter holes. The holes, which led to increased patient morbidity and costs, may be related to structural changes made in 2006 to the adapter.

  3. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  4. Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

    Science.gov (United States)

    Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel H; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G

    2015-08-01

    Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. © 2015 American Heart Association, Inc.

  5. Radiographic assessment of venous catheter position in children: Value of the lateral view

    International Nuclear Information System (INIS)

    Stark, D.D.; Brasch, R.C.; Gooding, C.A.

    1984-01-01

    Frontal chest radiographs can be misleading in the evaluation of central venous catheter placement. Lateral chest radiographs were obtained, in addition to the standard frontal radiographs, in 25 young children. In five (20%) of the children, the catheters were found to be malpositioned, and the frontal radiograph showed evidence of the abnormality in all five. The lateral radiographs also showed evidence of the abnormality in all five children; however, in three of the five, the lateral radiographs provided additional, more specific, diagnostic information. The lateral chest radiographs also demonstrated satisfactory catheter positioning in three other children in whom the frontal radiographs suggested abnormal positioning. Accurate assessment of catheter position was possible in all patients using both frontal and lateral chest radiographs. Injection of contrast material was not necessary to locate malpositioned catheters. Lateral radiographs are recommended whenever an abnormal catheter position is suspected clinically or from findings on the routine frontal radiograph. (orig.)

  6. The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Park, Sang Woo; Hwang, Dae Yong; Seong, Moo Kyung; Joh, Hee Kyung; Yoon, So Young; Cho, Yo Han; Choe, Won Hyeok [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-02-15

    We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4: mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon

  7. The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

    International Nuclear Information System (INIS)

    Chang, Il Soo; Park, Sang Woo; Hwang, Dae Yong; Seong, Moo Kyung; Joh, Hee Kyung; Yoon, So Young; Cho, Yo Han; Choe, Won Hyeok

    2011-01-01

    We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4: mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon

  8. [Catheter fracture and pulmonary embolization of the distal fragment: a rare complication of the totally implantable venous access port].

    Science.gov (United States)

    Rebahi, H; El Adib, A G; Mouaffak, Y; El Hattaoui, M; Chaara, A; Sadek, H; Khouchani, M; Mahmal, L; Younous, S

    2015-01-01

    Totally implantable venous access port plays a crucial role in the treatment of patients in oncology. However, its use can result sporadically in catheter fracture with catheter tip embolization into pulmonary arteries. We report this unusual but potentially serious complication in four patients. In these patients, the port had been inserted percutaneously into the subclavian vein using the infra-clavicular approach. This side effect occurred late in three patients. In all patients, the catheter fracture was asymptomatic or pauci-symptomatic and was caused by the pinch-off syndrome. The retrieval of the embolized fragments was successfully performed by transcatheter procedure in the cardiac catheterisation laboratory. We reviewed the literature and the newest guidelines and recommendations to detail the clinico-radiological features, the possible causes of this complication and discussed means to recognize, manage and prevent it. Copyright © 2013 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  9. A Simplified Technique of Percutaneous Hepatic Artery Port-Catheter Insertion for the Treatment of Advanced Hepatocellular Carcinoma with Portal Vein Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Ah Hyun; Lee, Do Yun; Lee, Kwang Hun; Won, Jong Yun [Yonsei University College of Medicine, Severance Hospital, Seoul (Korea, Republic of); Kim, Kyung Ah [Inje University Ilsan Paik Hospital, Ilsan (Korea, Republic of)

    2010-12-15

    We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis

  10. Deep venous thrombosis in the lower extremity: catheter-directed thrombolysis

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Kim, En A; Park, Ki Han; Yoon, Kwon Ha; So, Byung Jun; Juhng, Seon Kwan; Won, Jin Jong [School of Medicine, Wonkwang University, Iksan (Korea, Republic of)

    2000-09-01

    To evaluate the efficacy of catheter-directed thrombolysis in treating symptomatic deep venous thrombosis (DVT) in lower limbs. Twenty-six consecutive patients (16 male and 10 female; mean age, 55 years) with lower extremity DVT underwent thrombolytic therapy. The duration of symptoms was 1-90 (mean, 17) days: 20 days or less in 16 cases (acute DVT) and less than 20 days in ten (chronic DVT). Catheter-directed infusions of urokinase were administered via ipsilateral popliteal veins, and angioplasty or stent placement was performed after the thrombolytic procedure. Oral medication of warfarin continued for six months, and for the evaluation of venous patency, follow-up ultrasonography was performed. The total dose of infused urokinase was 1,750,000-10,000,000 (mean 4,84,000) IU, and the total procedural time was 25-115 (mean, 64) hours. Lysis was complete in 16 cases (62%, all acute DVT), partial in five (19%, chronic DVT), and failed in five (19%, chronic DVT). Eight patients with venous stenosis and two with occlusion were treated by means of angioplasty (n=3D4) or Wallstent placement (n=3D6). Minor bleeding occurred in six cases and major complications in two (one of pulmonary embolism, and one of multiorgan failure). Catheter-directed thrombolysis with urokinase is effective for the treatment of DVT in lower limbs. (author)

  11. Deep venous thrombosis in the lower extremity: catheter-directed thrombolysis

    International Nuclear Information System (INIS)

    Roh, Byung Suk; Kim, En A; Park, Ki Han; Yoon, Kwon Ha; So, Byung Jun; Juhng, Seon Kwan; Won, Jin Jong

    2000-01-01

    To evaluate the efficacy of catheter-directed thrombolysis in treating symptomatic deep venous thrombosis (DVT) in lower limbs. Twenty-six consecutive patients (16 male and 10 female; mean age, 55 years) with lower extremity DVT underwent thrombolytic therapy. The duration of symptoms was 1-90 (mean, 17) days: 20 days or less in 16 cases (acute DVT) and less than 20 days in ten (chronic DVT). Catheter-directed infusions of urokinase were administered via ipsilateral popliteal veins, and angioplasty or stent placement was performed after the thrombolytic procedure. Oral medication of warfarin continued for six months, and for the evaluation of venous patency, follow-up ultrasonography was performed. The total dose of infused urokinase was 1,750,000-10,000,000 (mean 4,84,000) IU, and the total procedural time was 25-115 (mean, 64) hours. Lysis was complete in 16 cases (62%, all acute DVT), partial in five (19%, chronic DVT), and failed in five (19%, chronic DVT). Eight patients with venous stenosis and two with occlusion were treated by means of angioplasty (n=3D4) or Wallstent placement (n=3D6). Minor bleeding occurred in six cases and major complications in two (one of pulmonary embolism, and one of multiorgan failure). Catheter-directed thrombolysis with urokinase is effective for the treatment of DVT in lower limbs. (author)

  12. Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments

    Directory of Open Access Journals (Sweden)

    Rolf Bambauer

    2012-01-01

    Full Text Available Background. Catheter-related infections, thrombosis, and stenosis are among the most frequent complications associated with catheters, which are inserted in vessels. Surface treatment processes of the outer surface, such as ion-beam-assisted deposition, can be used to mitigate such complications. Methods. This retrospective study (1992–2007 evaluated silver-coated (54 patients and noncoated (105 patients implanted large-bore catheters used for extracorporeal detoxification. The catheters were inserted into the internal jugular or subclavian veins. After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays. They also were examined using scanning electron microscope. Results. The silver coated catheters showed a tendency towards longer in situ time. The microbiologic examinations of the catheter tips were in both catheter types high positive, but not significant. Conclusion. The silver-coated catheters showed no significantly reduction in infection rate by evaluation of all collected data in this retrospective study. There was no association between both catheters in significantly reducing savings in treatment costs and in reducing patient discomfort. Other new developed catheter materials such as the microdomain-structured inner and outer surface are considered more biocompatible because they mimic the structure of natural biological surface.

  13. Utilization of a biomedical device (VeinViewer® ) to assist with peripheral intravenous catheter (PIV) insertion for pediatric nurses.

    Science.gov (United States)

    McNeely, Heidi L; Ream, Theresa L; Thrasher, Jodi M; Dziadkowiec, Oliwier; Callahan, Tiffany J

    2018-04-01

    Vascular access in pediatric patients can be challenging even with the currently available technological resources. This nurse-driven research study explored time, cost, and resources for intravenous access to determine if a biomedical device, VeinViewer ® Vision, would facilitate improvements in pediatric access. In addition, this study looked at nurse perceptions of skills and confidence around intravenous insertion and if the use of the VeinViewer ® impacted these perceptions. Literature examining pediatric intravenous access success rates compared with nurse perceived skills and confidence is lacking. Nonblinded randomized control trial of pediatric nurses working in an acute care hospital setting. A preliminary needs assessment solicited feedback from nurses regarding their practice, perceived skills, and confidence with placing peripheral intravenous catheters (PIVs). Due to the results of the preliminary needs assessment, a research study was designed and 40 nurses were recruited to participate. The nurses were randomized into either a VeinViewer ® or standard practice group. Nurse participants placed intravenous catheters on hospitalized pediatric patients using established procedures while tracking data for the study. Needs assessment showed a majority of nurses felt a biomedical device would be helpful in building their intravenous insertion skills and their confidence. The study results did not demonstrate any clinically significant differences between VeinViewer ® use and standard practice for intravenous catheter insertion in pediatric patients for success of placement, number of attempts, or overall cost. In addition, no difference was noted between nurses in either group on perceived skills or confidence with insertion of PIVs. The ongoing need for resources focused on building nurse skills and confidence for PIV insertion was highlighted and organizations should continue to direct efforts toward developing skills and competency for staff that

  14. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  15. Ultrasound guided transrectal catheter drainage of pelvic collections.

    Science.gov (United States)

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  16. Benefits of postpyloric enteral access placement by a nutrition support dietitian.

    Science.gov (United States)

    Jimenez, L Lee; Ramage, James E

    2004-10-01

    Although enteral nutrition is considered the preferred strategy for nutrition support, it is often precluded by nasogastric feeding intolerance or the inability to place feeding access into the postpyloric position. In an effort to improve enteral nutrition (EN) outcomes at our institution, the nutrition support dietitian (NSD) began placing postpyloric feeding tubes (PPFT) in intensive care unit patients. Intensive care unit patients who received blind, bedside PPFT placements by the NSD (n = 18) were compared with a concurrent age- and diagnosis-matched control group that received standard nutritional care without NSD intervention (n = 18). Interruption of EN infusion, appropriateness of parenteral nutrition (PN) prescription (based on American Society of Parenteral and Enteral Nutrition guidelines), and incidence of ventilator-associated pneumonia (VAP), as defined by the American College of Chest Physicians practice guidelines, were determined in each group. The NSD was successful in positioning the PPFT at or distal to the third portion of the duodenum in 83% of attempts. The PPFT group demonstrated no interruption of enteral feeding compared with 56% in the control group (p VAP in the PPFT group (6% vs 28%, p = .07). Of the PN initiations in the control group, 88% were deemed to be potentially avoidable; 6 of 8 PNs were initiated because of gastric residuals. Enteral nutrition facilitated by NSD placement of postpyloric feeding access is associated with improved tube feeding tolerance and reduced PN use. Further studies are needed to evaluate a possible effect of postpyloric feeding on the incidence of VAP.

  17. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  18. Efficacy of Prophylactic Antibiotics at Peritoneal Catheter Insertion on Early Peritonitis: Data from the Catheter Section of the French Language Peritoneal Dialysis Registry.

    Science.gov (United States)

    Lanot, Antoine; Lobbedez, Thierry; Bechade, Clémence; Verger, Christian; Fabre, Emmanuel; Dratwa, Max; Vernier, Isabelle

    2016-01-01

    International guidelines recommend the use of a prophylactic antibiotic before the peritoneal dialysis (PD) catheter can be inserted. The main objective of this study was to assess whether this practice is associated with a lower risk of early peritonitis and to estimate the magnitude of the centre effect. A retrospective, multi-centric study was conducted, in which data from the French Language Peritoneal Dialysis Registry was analysed. Patients were separated into 2 groups based on whether or not prophylactic antibiotics were used prior to catheter placement. Out of the 2,014 patients who had a PD catheter placed between February 1, 2012 and December 31, 2014, 1,105 were given a prophylactic antibiotic. In a classical logit model, the use of prophylactic antibiotics was found to protect the individual against the risk of early peritonitis (OR 0.67, 95% CI 0.49-0.92). However, this association lost significance in a mixed logistic regression model with centre as a random effect: OR 0.73 (95% CI 0.48-1.09). Covariates associated with the risk of developing early peritonitis were age over 65: OR 0.73 (95% CI 0.39-0.85), body mass index over 35 kg/m2: OR 1.99 (95% CI 1.13-3.47), transfer to PD due to graft failure: OR 2.24 (95% CI 1.22-4.11), assisted PD: OR 1.96 (95% CI 1.31-2.93), and the use of the Moncrief technique: OR 3.07 (95% CI 1.85-5.11). There is a beneficial effect of prophylactic antibiotic used prior to peritoneal catheter placement, on the occurence of early peritonitis. However, the beneficial effect could be masked by a centre effect. © 2016 S. Karger AG, Basel.

  19. Ultrasound-guided antegrade access during laparoscopic pyeloplasty in infants less than one year of age: A point of technique

    Directory of Open Access Journals (Sweden)

    Arvind Ganpule

    2012-01-01

    Full Text Available Background: Access to urethras and ureters of infants may be hazardous and injurious through an endoscopic route. Placement and removal of stents in infants requires anaesthesia and access through these small caliber urethras. We describe our technique of placing antegrade splint during a laparoscopic pyeloplasty in these infants. Materials and Methods: An ultrasound-guided percutaneous renal access is obtained. Telescopic metal two part needle is passed into the kidney over a guide wire. A second guide wire is passed through the telescopic metal two part needle. The tract is dilated with 14 Fr screw dilator. Over one guide wire, a 5 Fr ureteric catheter is passed and coiled in the renal pelvis. Over the other wire, a 14 Fr malecot catheter is placed as nephrostomy. Laparoscopic pyeloplasty is then done. During pyelotomy, the ureteric catheter is pulled and advanced through the ureter before the pyeloplasty is completed. The ureteric catheter thus acts as a splint across the anastomosis. Ureteric catheter is removed on the 3 rd post operative day and nephrostomy is clamped. Nephrostomy is removed on 4 th post operative day if child is asymptomatic. The modified technique was successfully done in five patients aged less than one year old. All patients tolerated the procedure well. Post operative period was uneventful in all. Conclusion: Ultrasound-guided ante grade nephroureteral ureteral splint for infant laparoscopic pyeloplasty is safe. It avoids the need for urethral instrumentation for insertion and removal of stents in these small patients.

  20. Real-Time Ultrasound-Guided Catheter Navigation for Approaching Deep-Seated Brain Lesions: Role of Intraoperative Neurosonography with and without Fusion with Magnetic Resonance Imaging.

    Science.gov (United States)

    Manjila, Sunil; Karhade, Aditya; Phi, Ji Hoon; Scott, R Michael; Smith, Edward R

    2017-01-01

    Brain shift during the exposure of cranial lesions may reduce the accuracy of frameless stereotaxy. We describe a rapid, safe, and effective method to approach deep-seated brain lesions using real-time intraoperative ultrasound placement of a catheter to mark the dissection trajectory to the lesion. With Institutional Review Board approval, we retrospectively reviewed the radiographic, pathologic, and intraoperative data of 11 pediatric patients who underwent excision of 12 lesions by means of this technique. Full data sets were available for 12 lesions in 11 patients. Ten lesions were tumors and 2 were cavernous malformations. Lesion locations included the thalamus (n = 4), trigone (n = 3), mesial temporal lobe (n = 3), and deep white matter (n = 2). Catheter placement was successful in all patients, and the median time required for the procedure was 3 min (range 2-5 min). There were no complications related to catheter placement. The median diameter of surgical corridors on postresection magnetic resonance imaging was 6.6 mm (range 3.0-12.1 mm). Use of real-time ultrasound guidance to place a catheter to aid in the dissection to reach a deep-seated brain lesion provides advantages complementary to existing techniques, such as frameless stereotaxy. The catheter insertion technique described here provides a quick, accurate, and safe method for reaching deep-seated lesions. © 2017 S. Karger AG, Basel.

  1. Development of Decision-Making Automated System for Optimal Placement of Physical Access Control System’s Elements

    Science.gov (United States)

    Danilova, Olga; Semenova, Zinaida

    2018-04-01

    The objective of this study is a detailed analysis of physical protection systems development for information resources. The optimization theory and decision-making mathematical apparatus is used to formulate correctly and create an algorithm of selection procedure for security systems optimal configuration considering the location of the secured object’s access point and zones. The result of this study is a software implementation scheme of decision-making system for optimal placement of the physical access control system’s elements.

  2. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  3. Large-volume paracentesis with indwelling peritoneal catheter and albumin infusion: a community hospital study

    Directory of Open Access Journals (Sweden)

    Daniel K. Martin

    2016-10-01

    Full Text Available Background: The management of ascites can be problematic. This is especially true in patients with diuretic refractory ascites who develop a tense abdomen. This often results in hypotension and decreased venous return with resulting renal failure. In this paper, we further examine the risks and benefits of utilizing an indwelling peritoneal catheter to remove large-volume ascites over a 72-h period while maintaining intravascular volume and preventing renal failure. Methods: We retrospectively reviewed charts and identified 36 consecutive patients undergoing continuous large-volume paracentesis with an indwelling peritoneal catheter. At the time of drain placement, no patients had signs or laboratory parameters suggestive of spontaneous bacterial peritonitis. The patients underwent ascitic fluid removal through an indwelling peritoneal catheter and were supported with scheduled albumin throughout the duration. The catheter was used to remove up to 3 L every 8 h for a maximum of 72 h. Regular laboratory and ascitic fluid testing was performed. All patients had a clinical follow-up within 3 months after the drain placement. Results: An average of 16.5 L was removed over the 72-h time frame of indwelling peritoneal catheter maintenance. The albumin infusion utilized correlated to 12 mg/L removed. The average creatinine trend improved in a statistically significant manner from 1.37 on the day of admission to 1.21 on the day of drain removal. No patients developed renal failure during the hospital course. There were no documented episodes of neutrocytic ascites or bacterial peritonitis throughout the study review. Conclusion: Large-volume peritoneal drainage with an indwelling peritoneal catheter is safe and effective for patients with tense ascites. Concomitant albumin infusion allows for maintenance of renal function, and no increase in infectious complications was noted.

  4. Suicide by severing the arterio-venous subclavian dialysis catheter.

    Science.gov (United States)

    Edirisinghe, P A S; Busuttil, A

    2006-02-01

    Haemodialysis access is an essential requirement for haemodialysis treatment in end-stage renal disease. The common forms are arteriovenous fistula (AVF) and arteriovenous grafts in ante-cubital fossa, forearm and upper thigh. Sometimes temporary or immediate access is created via a subclavian catheter or internal jugular catheter. This report is on a 79-year-old man who was suffering from chronic renal failure with a non-functional peripheral AVF; he was being dialysed through a permanent subclavian catheter and he became depressed due to continuing deterioration of his health. He used the easily accessible haemodialysis site as the method of suicide by cutting the tube that connected with the main vessel in his chest and bled to death. This highlights the requirement to assess carefully the patient's mental state in those on chronic haemodialysis, even though very few similar fatal cases have been previously reported.

  5. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  6. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    Energy Technology Data Exchange (ETDEWEB)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K [Medical University of South Carolina, Charleston, SC (United States)

    2016-06-15

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  7. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    International Nuclear Information System (INIS)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K

    2016-01-01

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  8. Two years experience with tunneled dialysis catheters in patients requiring haemodialysis

    International Nuclear Information System (INIS)

    Raheem, A.; Rana, A. I.; Ramzan, M.; Shah, R. A.; Mehmood, S. N.; Naseem, S.

    2014-01-01

    Objective: To look for survival rate and major reasons behind the failure of tunnelled dialysis catheters in patients on haemodialysis. Methods: The retrospective study was conducted at the Department of Interventional Radiology, Shifa International Hospital, Islamabad, and comprised records of 100 consecutive subjects from a list of patients in whom tunnelled cuffed catheters were placed from February 2009 to January 2011 and were followed up for two years. Data was collected on a proforma from the hospital database and medical records of patients. SPSS 19 was used for statistical analysis. Results: Of the total 122 catheters placed in 100 patients, 49(40.16%) were lost to follow-up. Of the remaining 73(59.83%) catheters, 38(52%) had achieved their desired function, while 35(48%) failed to achieve the target duration. Among the reasons of catheter failure, infection was the commonest at 13(37.14%) with infection rate of 0.24 per 1000 catheter days. According to Kaplan Meier analysis, catheter survival rates at 60, 90 and 180 days were 89%, 77% and 64% respectively. Mean effective duration of catheter was 129+-117 days. Conclusion: Tunnelled dialysis catheters can be safely used as vascular access till the maturation of fistula and may be an alternative to Arterio-Venous Fistula or graft for long-term vascular access if indicated. (author)

  9. Frequency of nursing care of vascular access in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Iman Taghizade Firoozjayi

    2016-03-01

    Full Text Available Background: Hemodialysis is a critical treatment method, which depends on the vascular access route. Lack of care for the vascular access route could diminish its efficiency in a short time. Regarding this, the present study aimed to evaluate the frequency of nursing care for vascular access route in the hemodialysis patients. Methods: This cross-sectional study was conducted on 20 nurses and 120 hemodialysis patients, who referred to the Hemodialysis Department of Shahid Beheshti Hospital, Babol, Iran, in 2015. The method of nursing care for vascular access route was evaluated using a researcher-made checklist. The data analysis was performed using the descriptive statistics in the SPSS version 16. Results: In total, 14 cases of nursing care were evaluated, in 100% of which all the caring steps, including wearing gloves and a mask, early bolus injections of heparin, washing the catheter tubing, frequent monitoring of blood pressure, rinsing the catheter tubing, returning the blood to the body after hemodialysis, and sterile covering of the puncture site, were observed. However, some of the other techniques, such as the care related to appropriate pump speed when starting the dialysis machine (81.66%, observance of the needle distance from fistula (75.83%, appropriate placement of catheter (75%, pressing the injection site (54.17%, blood pressure monitoring at the end of dialysis (50%, and change of the needle site between two sessions (27.5%, were not adhered to by the nurses. Conclusion: According to the results of this study, some of the nursing care steps, which are necessary in the beginning and end of the hemodialysis, were not accurately followed by the nurses. It is recommended that constant training courses be held for the nurses in this regard.

  10. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Schellhammer, Frank; Esch, Jan Schulte am; Hammerschlag, Sascha; Knoefel, Wolfram Trudo; Fuerst, Guenter

    2008-01-01

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  11. Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

    International Nuclear Information System (INIS)

    Hashimoto, Aya; Tanaka, Toshihiro; Sho, Masayuki; Nishiofuku, Hideyuki; Masada, Tetsuya; Sato, Takeshi; Marugami, Nagaaki; Anai, Hiroshi; Sakaguchi, Hiroshi; Kanno, Masatoshi; Tamamoto, Tetsuro; Hasegawa, Masatoshi; Nakajima, Yoshiyuki; Kichikawa, Kimihiko

    2016-01-01

    PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

  12. Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Aya; Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp [Nara Medical University, Department of Radiology (Japan); Sho, Masayuki [Nara Medical University, Department of Surgery (Japan); Nishiofuku, Hideyuki; Masada, Tetsuya; Sato, Takeshi; Marugami, Nagaaki [Nara Medical University, Department of Radiology (Japan); Anai, Hiroshi [Nara City Hospital, Department of Radiology (Japan); Sakaguchi, Hiroshi [Nara Prefectural Western Medical Center, Department of Radiology (Japan); Kanno, Masatoshi [Nara Medical University, Oncology Center (Japan); Tamamoto, Tetsuro; Hasegawa, Masatoshi [Nara Medical University, Department of Radiation Oncology (Japan); Nakajima, Yoshiyuki [Nara Medical University, Department of Surgery (Japan); Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2016-06-15

    PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

  13. Central Venous Access

    International Nuclear Information System (INIS)

    Ganeshan, Arul; Warakaulle, Dinuke R.; Uberoi, Raman

    2007-01-01

    Central venous access plays an important role in the management of an ever-increasing population of patients ranging from those that are critically ill to patients with difficult clinical access. Interventional radiologists are key in delivering this service and should be familiar with the wide range of techniques and catheters now available to them. A comprehensive description of these catheters with regard to indications, technical aspects of catheterization, success rates, and associated early and late complications, as well as a review of various published guidelines on central venous catheter insertion are given in this article

  14. Use of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement

    International Nuclear Information System (INIS)

    Bae, Jae-Ik; Shin, Ji Hoon; Song, Ho-Young; Yoon, Chang Jin; Nam, Deok Ho; Choi, Won-Chan; Lim, Jin-Oh

    2005-01-01

    Our purpose was to assess the safety and usefulness of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement. Two types of guiding sheath were made from straight polytetrafluoroethylene tubes. Type A was 80 cm in length, 4 mm in outer diameter and 3 mm in inner diameter. Type B was 70 cm in length, 6 mm in outer diameter and 5 mm in inner diameter. The type A sheath was used in 18 patients in whom a catheter-guide wire combination failed to pass through a stricture. The type B sheath was used in 22 patients in whom a stent delivery system failed to pass through the stricture due to loop formation within the gastric lumen. The overall success rate for guiding a catheter-guide wire through a stricture after using the type A sheath was 89%. The overall success rate for passing a stent delivery system through a stricture after using the type B sheath was 100%. All procedures were tolerated by the patients without any significant complications. The guiding sheaths were safe and useful in peroral fluoroscopic gastroduodenal stent placement. (orig.)

  15. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein.

    Science.gov (United States)

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-10-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.

  16. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein

    OpenAIRE

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-01-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common caro...

  17. WE-G-17A-05: Real-Time Catheter Localization Using An Active MR Tracker for Interstitial Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, W; Damato, A; Viswanathan, A; Cormack, R [Dana Farber Cancer Institute / Brigham and Women' s Hospital, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Penzkofer, T; Schmidt, E [Brigham and Women' s Hospital, Boston, MA (United States); Pan, L; Gilson, W [Siemens Corporation, Corporate Technology, Baltimore, MD (United States); Seethamraju, R [Siemens Healthcare, Boston, MA (United States)

    2014-06-15

    Purpose: To develop a novel active MR-tracking system which can provide accurate and rapid localization of brachytherapy catheters, and assess its reliability and spatial accuracy in comparison to standard catheter digitization using MR images. Methods: An active MR tracker for brachytherapy was constructed by adding three printed-circuit micro-coils to the shaft of a commercial metallic stylet. A gel phantom with an embedded framework was built, into which fifteen 14-Gauge catheters were placed, following either with parallel or crossed paths. The tracker was inserted sequentially into each catheter, with MR-tracking running continuously. Tracking was also performed during the tracker's removal from each catheter. Catheter trajectories measured from the insertion and the removal procedures using the same micro-coil were compared, as well as trajectories obtained using different micro-coils. A 3D high-resolution MR image dataset of the phantom was acquired and imported into a treatment planning system (TPS) for catheter digitization. A comparison between MR-tracked positions and positions digitized from MR images by TPS was performed. Results: The MR tracking shows good consistency for varying catheter paths and for all micro-coils (mean difference ∼1.1 mm). The average distance between the MR-tracking trajectory and catheter digitization from the MR images was 1.1 mm. Ambiguity in catheter assignment from images due to crossed paths was resolved by active tracking. When tracking was interleaved with imaging, real-time images were continuously acquired at the instantaneous tip positions and displayed on an external workstation. Conclusion: The active MR tracker may be used to provide an independent measurement of catheter location in the MR environment, potentially eliminating the need for subsequent CT. It may also be used to control realtime imaging of catheter placement. This will enable MR-based brachytherapy planning of interstitial implants without

  18. WE-G-17A-05: Real-Time Catheter Localization Using An Active MR Tracker for Interstitial Brachytherapy

    International Nuclear Information System (INIS)

    Wang, W; Damato, A; Viswanathan, A; Cormack, R; Penzkofer, T; Schmidt, E; Pan, L; Gilson, W; Seethamraju, R

    2014-01-01

    Purpose: To develop a novel active MR-tracking system which can provide accurate and rapid localization of brachytherapy catheters, and assess its reliability and spatial accuracy in comparison to standard catheter digitization using MR images. Methods: An active MR tracker for brachytherapy was constructed by adding three printed-circuit micro-coils to the shaft of a commercial metallic stylet. A gel phantom with an embedded framework was built, into which fifteen 14-Gauge catheters were placed, following either with parallel or crossed paths. The tracker was inserted sequentially into each catheter, with MR-tracking running continuously. Tracking was also performed during the tracker's removal from each catheter. Catheter trajectories measured from the insertion and the removal procedures using the same micro-coil were compared, as well as trajectories obtained using different micro-coils. A 3D high-resolution MR image dataset of the phantom was acquired and imported into a treatment planning system (TPS) for catheter digitization. A comparison between MR-tracked positions and positions digitized from MR images by TPS was performed. Results: The MR tracking shows good consistency for varying catheter paths and for all micro-coils (mean difference ∼1.1 mm). The average distance between the MR-tracking trajectory and catheter digitization from the MR images was 1.1 mm. Ambiguity in catheter assignment from images due to crossed paths was resolved by active tracking. When tracking was interleaved with imaging, real-time images were continuously acquired at the instantaneous tip positions and displayed on an external workstation. Conclusion: The active MR tracker may be used to provide an independent measurement of catheter location in the MR environment, potentially eliminating the need for subsequent CT. It may also be used to control realtime imaging of catheter placement. This will enable MR-based brachytherapy planning of interstitial implants without

  19. Randomised Controlled Trial to determine the appropriate time to initiate peritoneal dialysis after insertion of catheter to minimise complications (Timely PD study

    Directory of Open Access Journals (Sweden)

    Fassett Robert G

    2010-06-01

    Full Text Available Abstract Background The most appropriate time to initiate dialysis after surgical insertion of Tenckhoff catheters is not clear in the literature. There is the possibility of peritoneal dialysis (PD complications such as leakage and infection if dialysis is started too soon after insertion. However, much morbidity and expense could be saved by reducing dependency on haemodialysis (HD by earlier initiation of PD post catheter insertion. Previous studies are observational and mostly compare immediate with delayed use. The primary objective is to determine the safest and shortest time interval between surgical placement of a Tenckhoff catheter and starting PD. Methods/Design This is a randomised controlled trial of patients who will start PD after insertion of Tenckhoff catheter at Royal Brisbane and Women's Hospital (RBWH or Rockhampton Base Hospital (RBH who meet the inclusion criteria. Patients will be stratified by site and diabetic status. The patients will be randomised to one of three treatment groups. Group 1 will start PD one week after Tenckhoff catheter insertion, group 2 at two weeks and group 3 at four weeks. Nurses and physicians will be blinded to the randomised allocation. The primary end point is the complication rate (leaks and infection after initiation of PD. Discussion The study will determine the most appropriate time to initiate PD after placement of a Tenckhoff catheter. Trial Registration ACTRN12610000076077

  20. Simulation training for pediatric residents on central venous catheter placement: a pilot study.

    Science.gov (United States)

    Thomas, Scott M; Burch, Wesley; Kuehnle, Sarah E; Flood, Robert G; Scalzo, Anthony J; Gerard, James M

    2013-11-01

    To assess the effect of simulation training on pediatric residents' acquisition and retention of central venous catheter insertion skills. A secondary objective was to assess the effect of simulation training on self-confidence to perform the procedure. Prospective observational pilot study. Single university clinical simulation center. Pediatric residents, postgraduate years 1-3. Residents participated in a 60- to 90-minute ultrasound-guided central venous catheter simulation training session. Video recordings of residents performing simulated femoral central venous catheter insertions were made before (baseline), after, and at 3-month following training. Three blinded expert raters independently scored the performances using a 24-item checklist and 100-mm global rating scale. At each time point, residents rated their confidence to perform the procedure on a 100-mm scale. Twenty-six residents completed the study. Compared with baseline, immediately following training, median checklist score (54.2% [interquartile range, 40.8-68.8%] vs 83.3% [interquartile range, 70.0-91.7%]), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 79.5 mm [interquartile range, 16.3-91.7 mm]), success rate (38.5% vs 80.8%), and self-confidence (8.0 mm [interquartile range, 3.8-19.0 mm] vs 52.0 mm [interquartile range, 43.5-66.5 mm]) all improved (p interquartile range, 40.8-68.8%] vs 54.2% [interquartile range, 45.8-80.4%], p = 0.47), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 35.5 mm [interquartile range, 5.3-77.0], p = 0.62), and success rate (38.5% vs 65.4%, p = 0.35) were similar at 3-month follow-up. Self-confidence, however, remained above baseline at 3-month follow-up (8.0 mm [interquartile range, 3.8-19.0 mm] vs 61.0 mm [interquartile range, 31.5-71.8 mm], p < 0.01). Simulation training improved pediatric residents' central venous catheter insertion procedural skills. Decay in skills was found at 3-month follow-up. This suggests that

  1. Impact of Lesion Placement on Efficacy and Safety of Catheter-Based Radiofrequency Renal Denervation.

    Science.gov (United States)

    Mahfoud, Felix; Tunev, Stefan; Ewen, Sebastian; Cremers, Bodo; Ruwart, Jennifer; Schulz-Jander, Daniel; Linz, Dominik; Davies, Justin; Kandzari, David E; Whitbourn, Robert; Böhm, Michael; Melder, Robert J

    2015-10-20

    Insufficient procedural efficacy has been proposed to explain nonresponse to renal denervation (RDN). The aim of this study was to examine the impact of different patterns of lesion placements on the efficacy and consistency of catheter-based radiofrequency RDN in pigs. The impact of increasing number of lesions versus location of RDN was investigated in a porcine model (Group 1; n = 51). The effect of treating the main artery, the branches, and the 2 combined was compared in Group 2 (n = 48). The durability of response and safety of combined treatment of the main artery plus branches was examined in Group 3 (n = 16). Renal norepinephrine (NE) tissue content and renal cortical axon density were assessed. Increasing the number of RF lesions (4, 8, and 12) in the main renal artery was not sufficient to yield a clear dose-response relationship on NE content and axon density. In contrast, targeted treatment of the renal artery branches or distal segment of the main renal artery resulted in markedly less variability of response and significantly greater reduction of both NE and axon density than conventional treatment of only the main renal artery. Combination treatment (main artery plus branches) produced the greatest change in renal NE and axon density with the least heterogeneity. The changes were durable through 28 days post-treatment. These data provide the rationale for investigation of an optimized approach for RDN in future clinical studies. This may have profound implications for the clinical application of RDN, as this approach may not only achieve greater reductions in sympathetic activity but also reduce treatment effect variability. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Risk Factors Related to Peripherally Inserted Central Venous Catheter Nonselective Removal in Neonates

    Directory of Open Access Journals (Sweden)

    Xiaohe Yu

    2018-01-01

    Full Text Available We aimed to investigate the incidence and risk factors associated with nonselective removal of peripherally inserted central venous catheter (PICC in neonates. In this prospective cohort study, neonates who underwent PICC placement at neonatal intensive care units (NICUs in China from October 2012 to November 2015 were included. The patient demographics, catheter characteristics, catheter duration, PICC insertion site, indication for PICC insertion, infuscate composition, PICC tip location, and catheter complications were recorded in a computerized database. Risk factors for nonselective removal were analyzed. A total of 497 PICCs were placed in 496 neonates. Nonselective removal occurred in 9.3% of PICCs during 10,540 catheter-days (4.6 nonselective removals per 1,000 catheter-days. These included occlusion (3%, infection (1.4%, leakage (2.0%, phlebitis (0.6%, displacement (1%, pleural effusion(0.6%, and breaks (0.6%. Noncentral tip position was independently associated with an increased risk of nonselective removal (odds ratio 2.621; 95% confidence interval, 1.258-5.461 after adjusting for gestational age, sex, birth weight, and PICC dwell time. No significant differences in the rate of complications occurred between silastic and polyurethane PICC or different insertion sites. Noncentral PICC tip position was the only independent risk factor for nonselective removal of PICC.

  3. Effect of electromagnetic navigated ventriculoperitoneal shunt placement on failure rates.

    Science.gov (United States)

    Jung, Nayoung; Kim, Dongwon

    2013-03-01

    To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.

  4. Delayed vocal fold paralysis after continuous interscalene level brachial plexus block with catheter placement: a case report.

    Science.gov (United States)

    Gollapalli, Lakshman; McKelvey, George; Wang, Hong

    2014-08-01

    We report an incident of delayed onset of true vocal fold paralysis with continuous interscalene brachial plexus block. A 51 year old woman underwent left shoulder manipulation and lysis of adhesions with fluoroscopy and general anesthesia. An interscalene brachial plexus block was performed and a catheter with a continuous infusion pump was placed for postoperative pain control. Following hospital discharge, approximately 8 hours after the initial catheter bolus the patient developed hoarseness, dysphagia, and dyspnea, secondary to left vocal fold palsy. The patient was admitted for observation and the catheter was discontinued with no intubation required. By the next morning, the patient's dysphagia and dyspnea had resolved and her hoarseness improved. Copyright © 2014. Published by Elsevier Inc.

  5. A new device for the prevention of pulmonary embolism in critically ill patients: Results of the European Angel Catheter Registry.

    Science.gov (United States)

    Taccone, Fabio S; Bunker, Nicholas; Waldmann, Carl; De Backer, Daniel; Brohi, Karim; Jones, Robert G; Vincent, Jean-Louis

    2015-09-01

    Pulmonary embolism (PE) is a potentially life-threatening complication of critical illness. In trauma and neurosurgical patients with contraindications to anticoagulation, inferior vena cava (IVC) filters have been used to prevent PE, but their associated long-term complication rates and difficulties associated with filter removal have limited their use. The Angel catheter is a temporary device, which combined an IVC filter with a triple-lumen central venous catheter (IVC filter-catheter) and is intended for bedside placement and removal when no longer indicated. This study presents data from a European Registry of 60 critically ill patients in whom the IVC filter-catheter was used to prevent PE. The patients were all at high risk of PE development or recurrence and had contraindications to anticoagulation. The primary end points of this study were to evaluate the safety (in particular, the presence of infectious or thrombotic events) and effectiveness (the numbers of PEs and averted PEs) of the IVC filter-catheter. The main diagnosis before catheter insertion was major trauma in 33 patients (55%), intracerebral hemorrhage or stroke in 9 (15%), a venous thromboembolic event in 9 (15%), and active bleeding in 6 (10%). The IVC filter-catheter was placed as prophylaxis in 51 patients (85%) and as treatment in the 9 patients (15%) with venous thromboembolic event. The devices were inserted at the bedside without fluoroscopic guidance in 54 patients (90%) and within a median of 4 days after hospital admission. They were left in place for a mean of 6 days (4-8 days). One patient developed a PE, without hemodynamic compromise; two PEs were averted. No serious adverse events were reported. Early bedside placement of an IVC filter-catheter is possible, and our results suggest that this is a safe, effective alternative to short-term PE prophylaxis for high-risk patients with contraindications to anticoagulation. Therapeutic study, level V.

  6. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  7. Reducing catheter-associated urinary tract infections: a quality-improvement initiative.

    Science.gov (United States)

    Davis, Katherine Finn; Colebaugh, Ann M; Eithun, Benjamin L; Klieger, Sarah B; Meredith, Dennis J; Plachter, Natalie; Sammons, Julia Shaklee; Thompson, Allison; Coffin, Susan E

    2014-09-01

    Catheter-associated urinary tract infections (CAUTIs) are among the most common health care-associated infections in the United States, yet little is known about the prevention and epidemiology of pediatric CAUTIs. An observational study was conducted to assess the impact of a CAUTI quality improvement prevention bundle that included institution-wide standardization of and training on urinary catheter insertion and maintenance practices, daily review of catheter necessity, and rapid review of all CAUTIs. Poisson regression was used to determine the impact of the bundle on CAUTI rates. A retrospective cohort study was performed to describe the epidemiology of incident pediatric CAUTIs at a tertiary care children's hospital over a 3-year period (June 2009 to June 2012). Implementation of the CAUTI prevention bundle was associated with a 50% reduction in the mean monthly CAUTI rate (95% confidence interval: -1.28 to -0.12; P = .02) from 5.41 to 2.49 per 1000 catheter-days. The median monthly catheter utilization ratio remained unchanged; ∼90% of patients had an indication for urinary catheterization. Forty-four patients experienced 57 CAUTIs over the study period. Most patients with CAUTIs were female (75%), received care in the pediatric or cardiac ICUs (70%), and had at least 1 complex chronic condition (98%). Nearly 90% of patients who developed a CAUTI had a recognized indication for initial catheter placement. CAUTI is a common pediatric health care-associated infection. Implementation of a prevention bundle can significantly reduce CAUTI rates in children. Copyright © 2014 by the American Academy of Pediatrics.

  8. Successful catheter directed thrombolysis of IVC and renal vein occlusive thrombus.

    LENUS (Irish Health Repository)

    McCarthy, E

    2011-11-01

    Thrombus formation is a recognised complication of IVC filter placement, however IVC and bilateral renal vein occlusion secondary to thrombus is much less common. We present a case of infrahepatic caval and bilateral renal vein occlusion secondary to thrombosis of a suprarenal IVC filter. With progressive clinical deterioration and failure of conservative medical management the patient underwent successful mechanical disruption and catheter directed thrombolysis.

  9. Comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system in image-guided central venous catheter placement in children weighing less than 10 kg

    Energy Technology Data Exchange (ETDEWEB)

    Miraglia, Roberto; Maruzzelli, Luigi; Cortis, Kelvin; Gerasia, Roberta; Maggio, Simona; Luca, Angelo [Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Piazza, Marcello [Department of Anesthesia, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Tuzzolino, Fabio [Department of Information Technology, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy)

    2014-09-10

    Ultrasound-guided central venous puncture and fluoroscopic guidance during central venous catheter (CVC) positioning optimizes technical success and lowers the complication rates in children, and is therefore considered standard practice. The purpose of this study was to compare the radiation exposure levels recorded during CVC placement in children weighing less than 10 kg in procedures performed using an image intensifier-based angiographic system (IIDS) to those performed in a flat-panel detector-based interventional suite (FPDS). A retrospective review of 96 image-guided CVC placements, between January 2008 and October 2013, in 49 children weighing less than 10 kg was performed. Mean age was 8.2 ± 4.4 months (range: 1-22 months). Mean weight was 7.1 ± 2.7 kg (range: 2.5-9.8 kg). The procedures were classified into two categories: non-tunneled and tunneled CVC placement. Thirty-five procedures were performed with the IIDS (21 non-tunneled CVC, 14 tunneled CVC); 61 procedures were performed with the FPDS (47 non-tunneled CVC, 14 tunneled CVC). For non-tunneled CVC, mean DAP was 113.5 ± 126.7 cGy cm{sup 2} with the IIDS and 15.9 ± 44.6 cGy . cm{sup 2} with the FPDS (P < 0.001). For tunneled CVC, mean DAP was 84.6 ± 81.2 cGy . cm{sup 2} with the IIDS and 37.1 ± 33.5 cGy cm{sup 2} with the FPDS (P = 0.02). The use of flat-panel angiographic equipment reduces radiation exposure in small children undergoing image-guided CVC placement. (orig.)

  10. Unsatisfactory hepatic perfusion after placement of the infusaid pump: Angiographic correlation

    International Nuclear Information System (INIS)

    Andrews, J.C.; Williams, D.M.; Cho, K.J.; Knol, J.A.; Wahl, R.L.; Ensminger, W.D.

    1988-01-01

    Complete perfusion limited to the liver is essential to the success of regional chemotherapy for hepatic malignancy. Thirty-three patients with unsatisfactory hepatic artery perfusion scintigrams after surgical placement of a pump and catheter system were evaluated with selective angiography (31 cases) or digital subtraction angiography (DSA) via the pump side port (six cases). The cause of the perfusion defect was hepatic artery thrombosis (14 cases), extrahepatic flow through collaterals (13 cases), misplaced catheter (three cases), short proper hepatic artery without adequate length for mixing (two cases), and undefined (one case). DSA findings were diagnostic in only two cases. Angiographic findings directed attempted correction in 22 of 33 cases

  11. Hemodialysis Reliable Outflow (HeRO) device in end-stage dialysis access: a decision analysis model.

    Science.gov (United States)

    Dageforde, Leigh Anne; Bream, Peter R; Moore, Derek E

    2012-09-01

    The Hemodialysis Reliable Outflow (HeRO) dialysis access device is a permanent tunneled dialysis graft connected to a central venous catheter and is used in patients with end-stage dialysis access (ESDA) issues secondary to central venous stenosis. The safety and effectiveness of the HeRO device has previously been proven, but no study thus far has compared the cost of its use with tunneled dialysis catheters (TDCs) and thigh grafts in patients with ESDA. A decision analytic model was developed to simulate outcomes for patients with ESDA undergoing placement of a HeRO dialysis access device, TDC, or thigh graft. Outcomes of interest were infection, thrombosis, and ischemic events. Baseline values, ranges, and costs were determined from a systematic review of the literature. Total costs were based on 1 year of post-procedure outcomes. Sensitivity analyses were conducted to test model strength. The HeRO dialysis access device is the least costly dialysis access with an average 1-year cost of $6521. The 1-year cost for a TDC was $8477. A thigh graft accounted for $9567 in a 1-year time period. The HeRO dialysis access device is the least costly method of ESDA. The primary determinants of cost in this model are infection in TDCs and leg ischemia necessitating amputation in thigh grafts. Further study is necessary to incorporate patient preference and quality of life into the model. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  13. Pain and efficacy of local anesthetics for central venous access

    Directory of Open Access Journals (Sweden)

    William C Culp Jr

    2008-11-01

    Full Text Available William C Culp Jr1, Mohammed Yousaf2, Benjamin Lowry1, Timothy C McCowan3, William C Culp21Division of Cardiothoracic Anesthesiology, Scott and White Hospital, The Texas A&M University College of Medicine, Temple, TX, USA; 2Division of Interventional Radiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA; 3Department of Radiology, University of Mississippi Medical Center, Jackson, MS, USAPurpose: To compare pain during injection and efficacy of analgesia of local anesthetics during central venous line placement.Methods: Sixty-two patients were studied in a randomized, double-blinded prospective fashion. Patients received 1% lidocaine (L, buffered 1% lidocaine (LB, or 2% chloroprocaine (CP injected around the internal jugular vein for procedural analgesia for central venous access. Patients reported pain via a standard linear visual analog scale, with 0 representing no pain and 10 being the worst pain imaginable.Results: Overall patient perception of pain was better with CP and L than LB with mean scores of CP 2.4, L 2.6, LB 4.2. Pain with injection mean scores were CP 2.1, L 2.5, LB 3.2. Pain with catheter placement scores were CP 2.5, L 1.7, LB 3.4. Operator assessment of overall pain values were CP 1.9, L 2.2, LB 3.4. LB consistently scored the worst, though compared with CP, this only reached statistical significance in overall patient pain and pain at catheter insertion compared with L.Conclusion: Though chloroprocaine scored better than lidocaine in 3 of 4 parameters, this trend did not achieve statistical significance. Adding sodium bicarbonate to lidocaine isn’t justified in routine practice, nor is routine replacement of lidocaine with chloroprocaine.Keywords: local anesthesia, analgesia, central venous access, lidocaine, chloroprocaine

  14. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    Science.gov (United States)

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  15. Evaluation of the fetal dose during prophylactic placement of internal iliac artery balloon occlusion catheters in placenta accreta

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Sik [Dept. of Radiology, Gachon University Gil hospital, Incheon (Korea, Republic of); Ahn, Sung Min [Dept. of Radiological Science, Gachon University, Incheon (Korea, Republic of)

    2016-09-15

    Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38∼8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49∼18.27 mGy.

  16. Urinary catheters

    Science.gov (United States)

    Catheter - urine; Foley catheter; Indwelling catheter; Suprapubic catheters ... stones Blood infections ( septicemia ) Blood in the urine (hematuria) Kidney damage (usually only with long-term, indwelling ...

  17. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  18. Percutaneous retrieval of centrally embolized fragments of central venous access devices or knotted Swan-Ganz catheters. Clinical report of 14 retrievals with detailed angiographic analysis and review of procedural aspects

    Directory of Open Access Journals (Sweden)

    Łukasz Kalińczuk

    2016-05-01

    Full Text Available Introduction: Totally implantable venous access systems (TIVAS, Swan-Ganz (SG and central venous catheters (CVC allow easy and repetitive entry to the central cardiovascular system. Fragments of them may be released inadvertently into the cardiovascular system during their insertion or as a result of mechanical complications encountered during long-term utilization. Aim : To present results of percutaneous retrieval of embolized fragments of central venous devices or knotted SG and review the procedural aspects with a series of detailed angiographies. Material and methods : Between January 2003 and December 2012 there were 14 (~0.025% successful retrievals in 13 patients (44 ±16 years, 15% females of embolized fragments of TIVAS (n = 10 or CVC (n = 1 or of dislodged guide-wires (n = 2 or knotted SG (n = 1. Results : Foreign bodies with the forward end located in the right ventricle (RV, as well as those found in the pulmonary artery (PA, often required repositioning with a pigtail catheter as compared to those catheter fragments which were located in the right atrium (RA and/or great vein and possessed an accessible free end allowing their direct ensnarement with the loop snare (57.0% (4/7 vs. 66.7% (2/3 vs. 0.0% (0/3; p = 0.074 respectively. Procedure duration was 2–3 times longer among catheters retrieved from the PA than among those with the forward edge located in the RV or RA (30 (18–68 vs. 13.5 (11–37 vs. 8 min (8–13; p = 0.054 respectively. The SG catheter knotted in the vena cava superior (VCS was encircled with the loop snare introduced transfemorally, subsequently cut at its skin entrance and then pulled down inside the 14 Fr vascular sheath. Conclusions : By using the pigtail catheter and the loop snare, it is feasible to retrieve centrally embolized fragments or knotted central venous access devices.

  19. A survey of the use of arterial catheters in anesthetized dogs and cats: 267 cases.

    Science.gov (United States)

    Trim, Cynthia M; Hofmeister, Erik H; Quandt, Jane E; Shepard, Molly K

    2017-01-01

    To describe the clinical practice of insertion of arterial catheters in anesthetized dogs and cats, to document complications of arterial catheterization, and to determine risk factors associated with the complications. Prospective clinical study and retrospective evaluation of medical records. University teaching hospital. Dogs (n = 251) and 13 cats anesthetized for clinical procedures with arterial catheters inserted for blood pressure monitoring. None. Details of the animal and catheter were collected at the time of anesthesia. On the following day, the catheter site was palpated and observed for abnormalities and the medical records of all animals were reviewed retrospectively for complications. Details of catheter placement were available for 216 catheters: 158 catheters in a dorsal pedal artery, 50 catheters in the median caudal (coccygeal) artery, 6 in the median artery, and 1 each in a cranial tibial and lingual artery. Blood pressure was obtained from 200 catheters, and 12 catheters failed before the end of anesthesia. Postoperative observational data obtained from 112 catheters described a palpable arterial pulse at 73 sites and no pulse at 21 sites. No risk factor for arterial occlusion was identified. No complications resulting from arterial catheterization were noted in the medical records. Arterial catheterization resulted in loss of a peripheral pulse postoperatively in 21/94 (22.3%) of animals examined, although no evidence of tissue ischemia was noted in the medical records of any of the patients in this study. These results suggest that insertion of a catheter in the dorsal pedal or coccygeal arteries was not associated with a high risk for complications. However, the course of arterial occlusion postoperatively warrants further investigation. © Veterinary Emergency and Critical Care Society 2016.

  20. Magnetic resonance imaging guided transatrial electrophysiological studies in swine using active catheter tracking - experience with 14 cases

    Energy Technology Data Exchange (ETDEWEB)

    Grothoff, Matthias; Gutberlet, Matthias [University of Leipzig - Heart Center, Department of Radiology, Leipzig (Germany); Hindricks, Gerhard; Sommer, Philipp; Hilbert, Sebastian [University of Leipzig - Heart Center, Department of Electrophysiology, Leipzig (Germany); Fleiter, Christian [Helios Klinikum Berlin-Buch, Department of Orthopaedic Surgery, Berlin (Germany); Schnackenburg, Bernhard [Philips Healthcare, Hamburg (Germany); Weiss, Steffen; Krueger, Sascha [Philips Innovative Technologies, Hamburg (Germany); Piorkowski, Christopher; Gaspar, Thomas [University of Dresden - Heart Center, Department of Electrophysiology, Dresden (Germany); Wedan, Steve; Lloyd, Thomas [Imricor Medical Systems, Burnsville, MN (United States)

    2017-05-15

    To evaluate the feasibility of performing comprehensive Cardiac Magnetic resonance (CMR) guided electrophysiological (EP) interventions in a porcine model encompassing left atrial access. After introduction of two femoral sheaths 14 swine (41 ± 3.6 kg) were transferred to a 1.5 T MR scanner. A three-dimensional whole-heart sequence was acquired followed by segmentation and the visualization of all heart chambers using an image-guidance platform. Two MR conditional catheters were inserted. The interventional protocol consisted of intubation of the coronary sinus, activation mapping, transseptal left atrial access (n = 4), generation of ablation lesions and eventually ablation of the atrioventricular (AV) node. For visualization of the catheter tip active tracking was used. Catheter positions were confirmed by passive real-time imaging. Total procedure time was 169 ± 51 minutes. The protocol could be completed in 12 swine. Two swine died from AV-ablation induced ventricular fibrillation. Catheters could be visualized and navigated under active tracking almost exclusively. The position of the catheter tips as visualized by active tracking could reliably be confirmed with passive catheter imaging. Comprehensive CMR-guided EP interventions including left atrial access are feasible in swine using active catheter tracking. (orig.)

  1. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

    Science.gov (United States)

    Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D

    2001-10-01

    The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

  2. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    Science.gov (United States)

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  3. Cardiac pacemaker dysfunction in children after thoracic drainage catheter manipulation.

    Science.gov (United States)

    Lobdell, K W; Walters, H L; Hudson, C; Hakimi, M

    1997-05-01

    Two children underwent placement of permanent, epicardial-lead, dual-chamber, unipolar pacemaker systems for complete heart block. Postoperatively, both patients demonstrated subcutaneous emphysema-in the area of their pulse generators-temporally related to thoracic catheter manipulation. Acutely, each situation was managed with manual compression of the pulse generator, ascertaining appropriate pacemaker sensing and pacing. Maintenance of compression with pressure dressings, vigilant observation/monitoring, and education of the care givers resulted in satisfactory pacemaker function without invasive intervention.

  4. [Catheter-associated bloodstream infections: implementation of a new consensus protocol].

    Science.gov (United States)

    Urrea Ayala, M; Rozas Quesada, L

    2009-07-01

    Catheter-associated bloodstream infection is highly prevalent and often associated with fatal complications. Some studies have shown that applying preventive interventions could help to reduce and control this type of infection. To determine whether a new consensus protocol for the manipulation and maintenance of central venous catheters would decrease catheter-associated bloodstream infections (CA-BSIs) in paediatric patients. To evaluate its compliance in intensive care units. Prospective study in the paediatric (PICU) and neonatal (NICU) intensive cares units, haematology, oncology and hospital wards in a Maternal and Paediatric reference Hospital in Barcelona. The study period is divided into two periods: before (first semester) and after the start of the new protocol (second semester) in 2007. The most important changes have been the insertion of the hermetic connection in the proximal and distal site (between the line and the syringe) of the central venous catheter (CVC), the labelling of the medication line and the CVC with the date of placement. A check-list to evaluate compliance was introduced in both intensive care units (paediatrics and neonatal) during the second study period. The rates of bloodstream infection per 1000 catheter-days were assessed. The rate of bloodstream infections per 1000 catheter-days before and after the start of the new protocol was 5.7 and 4.9 in PICU; 24.6 and 18.0 in NICU; 7.6 and 4.6 in haematology-oncology, and 11.9 and 10.3 in hospital wards. As regards compliance to the protocol, we found that proximal sealed connectors were used in more than 95% of the cases and up to 85% of the central venous catheter were labelled with the insertion date in both intensive care units. A consensus protocol for the use and maintenance of central venous catheters and healthcare worker training helped to control the rate of CA-BSIs. We reaffirm the importance of epidemiological surveillance as a measure for controlling nosocomial infections.

  5. Inpatient Peripherally Inserted Central Venous Catheter Complications: Should Peripherally Inserted Central Catheter Lines Be Placed in the Intensive Care Unit Setting?

    Science.gov (United States)

    Martyak, Michael; Kabir, Ishraq; Britt, Rebecca

    2017-08-01

    Peripherally inserted central venous catheters (PICCs) are now commonly used for central access in the intensive care unit (ICU) setting; however, there is a paucity of data evaluating the complication rates associated with these lines. We performed a retrospective review of all PICCs placed in the inpatient setting at our institution during a 1-year period from January 2013 to December 2013. These were divided into two groups: those placed at the bedside in the ICU and those placed by interventional radiology in non-ICU patients. Data regarding infectious and thrombotic complications were collected and evaluated. During the study period, 1209 PICC line placements met inclusion criteria and were evaluated; 1038 were placed by interventional radiology in non-ICU patients, and 171 were placed at the bedside in ICU patients. The combined thrombotic and central line associated blood stream infection rate was 6.17 per cent in the non-ICU group and 10.53 per cent in the ICU group (P = 0.035). The thrombotic complication rate was 5.88 per cent in the non-ICU group and 7.60 per cent in the ICU group (P = 0.38), whereas the central line associated blood stream infection rate was 0.29 per cent in the non-ICU group and 2.92 per cent in the ICU group (P = 0.002). This study seems to suggest that PICC lines placed at the bedside in the ICU setting are associated with higher complication rates, in particular infectious complications, than those placed by interventional radiology in non-ICU patients. The routine placement of PICC lines in the ICU settings needs to be reevaluated given these findings.

  6. Abduction of Arm Facilitates Correction of Kinked Peel-Away Sheath During Subclavian Central Line Placement.

    Science.gov (United States)

    Kim, Sunghoon

    2015-12-01

    A tunneled central line catheter placement using a subclavian vein approach can be complicated by an occurrence of peel-away sheath kink which prevents the advancement of the catheter through the sheath. The kink is created due to the angular junction of subclavian and brachiocephalic veins which meet at 90 degree angle. A technique is described which corrects the peel-away sheath kink by extending the subclavian/brachiocephalic vein angle to greater than 90 degrees by abducting the patient's arm. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  9. In the absence of a central venous catheter, risk of venous thromboembolism is low in critically injured children, adolescents, and young adults: evidence from the National Trauma Data Bank.

    Science.gov (United States)

    O'Brien, Sarah H; Candrilli, Sean D

    2011-05-01

    To describe the incidence and risk factors of venous thromboembolism in a large sample of critical care pediatric, adolescent, and young adult trauma patients. The National Trauma Data Bank-the largest and most complete aggregation of trauma registry data in the United States. Seven hundred eighty-four level I to level IV trauma centers. Patients ≤ 21 yrs of age who spent at least 1 day in a critical care unit during a trauma admission between 2001 and 2005. To characterize differences between patients with and without venous thromboembolism, we extracted variables regarding patient demographics, injury pattern and severity, procedures, total length of stay, and intensive care unit and ventilator days. Odds ratios for predictors of venous thromboembolism were estimated with a logistic regression model. Among the 135,032 critical care patients analyzed, venous thromboembolism was uncommon (6 per 1,000 discharges). Placement of a central venous catheter was a significant predictor of venous thromboembolism (odds ratio = 2.24; p central venous catheter were of even greater magnitude, particularly in adolescents and young adults. The risk of venous thromboembolism in critical care patients without a central venous catheter was central venous access.

  10. Persistent seroma after intraoperative placement of MammoSite for accelerated partial breast irradiation: Incidence, pathologic anatomy, and contributing factors

    International Nuclear Information System (INIS)

    Evans, Suzanne B.; Kaufman, Seth A.; Price, Lori Lyn; Cardarelli, Gene; Dipetrillo, Thomas A.; Wazer, David E.

    2006-01-01

    Purpose: To investigate the incidence of, and possible factors associated with, seroma formation after intraoperative placement of the MammoSite catheter for accelerated partial breast irradiation. Methods and Materials: This study evaluated 38 patients who had undergone intraoperative MammoSite catheter placement at lumpectomy or reexcision followed by accelerated partial breast irradiation with 34 Gy in 10 fractions. Data were collected regarding dosimetric parameters, including the volume of tissue enclosed by the 100%, 150%, and 200% isodose shells, dose homogeneity index, and maximal dose at the surface of the applicator. Clinical and treatment-related factors were analyzed, including patient age, patient weight, history of diabetes and smoking, use of reexcision, interval between surgery and radiotherapy, total duration of catheter placement, total excised specimen volume, and presence or absence of postprocedural infection. Seroma was verified by clinical examination, mammography, and/or ultrasonography. Persistent seroma was defined as seroma that was clinically detectable >6 months after radiotherapy completion. Results: After a median follow-up of 17 months, the overall rate of any detectable seroma was 76.3%. Persistent seroma (>6 months) occurred in 26 (68.4%) of 38 patients, of whom 46% experienced at least modest discomfort at some point during follow-up. Of these symptomatic patients, 3 required biopsy or complete cavity excision, revealing squamous metaplasia, foreign body giant cell reaction, fibroblasts, and active collagen deposition. Of the analyzed dosimetric, clinical, and treatment-related variables, only body weight correlated positively with the risk of seroma formation (p = 0.04). Postprocedural infection correlated significantly (p = 0.05) with a reduced risk of seroma formation. Seroma was associated with a suboptimal cosmetic outcome, because excellent scores were achieved in 61.5% of women with seroma compared with 83% without seroma

  11. Thoracic Nerve Root Entrapment by Intrathecal Catheter Coiling: Case Report and Review of the Literature.

    Science.gov (United States)

    Han, Jing L; Loriaux, Daniel B; Tybout, Caroline; Kinon, Merritt D; Rahimpour, Shervin; Runyon, Scott L; Hopkins, Thomas J; Boortz-Marx, Richard L; Lad, Shivanand P

    2016-03-01

    Intrathecal catheter placement has long-term therapeutic benefits in the management of chronic, intractable pain. Despite the diverse clinical applicability and rising prevalence of implantable drug delivery systems in pain medicine, the spectrum of complications associated with intrathecal catheterization remains largely understudied and underreported in the literature. To report a case of thoracic nerve root entrapment resulting from intrathecal catheter migration. Case report. Inpatient hospital service. A 60-year-old man status post implanted intrathecal (IT) catheter for intractable low back pain secondary to failed back surgery syndrome returned to the operating room for removal of IT pump trial catheter after experiencing relapse of preoperative pain and pump occlusion. Initial attempt at ambulatory removal of the catheter was aborted after the patient reported acute onset of lower extremity radiculopathic pain during the extraction. Noncontrast computed tomography (CT) subsequently revealed that the catheter had ascended and coiled around the T10 nerve root. The patient was taken back to the operating room for removal of the catheter under fluoroscopic guidance, with possible laminectomy for direct visualization. Removal was ultimately achieved with slow continuous tension, with complete resolution of the patient's new radicular symptoms. This report describes a single case report. This case demonstrates that any existing loops in the intrathecal catheter during initial implantation should be immediately re-addressed, as they can precipitate nerve root entrapment and irritation. Reduction of the loop or extrication of the catheter should be attempted under continuous fluoroscopic guidance to prevent further neurosurgical morbidity.

  12. Implementation of the updated 2015 Commission for Hospital Hygiene and Infection Prevention (KRINKO) recommendations "Prevention and control of catheter-associated urinary tract infections" in the hospitals in Frankfurt/Main, Germany.

    Science.gov (United States)

    Heudorf, Ursel; Grünewald, Miriam; Otto, Ulla

    2016-01-01

    The Commission for Hospital Hygiene and Infection Prevention (KRINKO) updated the recommendations for the prevention of catheter-associated urinary tract infections in 2015. This article will describe the implementation of these recommendations in Frankfurt's hospitals in autumn, 2015. In two non-ICU wards of each of Frankfurt's 17 hospitals, inspections were performed using a checklist based on the new KRINKO recommendations. In one large hospital, a total of 5 wards were inspected. The inspections covered the structure and process quality (operating instructions, training, indication, the placement and maintenance of catheters) and the demonstration of the preparation for insertion of a catheter using an empty bed and an imaginary patient, or insertion in a model. Operating instructions were available in all hospital wards; approximately half of the wards regularly performed training sessions. The indications were largely in line with the recommendations of the KRINKO. Alternatives to urinary tract catheters were available and were used more often than the urinary tract catheters themselves (15.9% vs. 13.5%). In accordance with the recommendations, catheters were placed without antibiotic prophylaxis or the instillation of antiseptic or antimicrobial substances or catheter flushing solutions. The demonstration of catheter placement was conscientiously performed. Need for improvement was seen in the daily documentation and the regular verification of continuing indication for a urinary catheter, as well as the omission of regular catheter change. Overall, the recommendations of the KRINKO on the prevention of catheter-associated urinary tract infections were adequately implemented. However, it cannot be ruled out that in situations with time pressure and staff shortage, the handling of urinary tract catheters may be of lower quality than that observed during the inspections, when catheter insertion was done by two nurses. Against this background, a sufficient

  13. [Complications associated to central venous catheters in hematology patients].

    Science.gov (United States)

    García-Gabás, Carmen; Castillo-Ayala, Ana; Hinojo-Marín, Begoña; Muriel-Abajo, M Ángeles; Gómez-Gutiérrez, Isabel; de Mena-Arenas, Ana M; Rodríguez-Gonzalo, Ana; Chao-Lozano, Cristina; García-Menéndez, Carmen; Madroñero-Agreda, M Antonia

    2015-01-01

    To discover the incidence of central venous catheters (tunnelled, subcutaneous and PICC) in patients with onco-hematological conditions, hospitalized in the Hematology or Transplantations of Hematopoietic Stem Cells Units, in two tertiary care hospitals. A cross-sectional, descriptive study form was developed in order to gather sociodemographic, clinical data as well as complications and follow-up of the care protocol. Each catheter was assigned a correlative identification number. Information was collected on 366 catheters: 185 in the University Hospital Ramón y Cajal (HURYC), 80 tunnelled, 40 subcutaneous venous access and 65 PICC, and 181 in the University Hospital Gregorio Marañón (HUGM), 101 tunnelled and 80 subcutaneous venous access. Major complications in the tunnellized were infections (13.7% in HURYC vs. 6.8% in HUGM - p<0.001) and occlusions (at least once in 3.8% vs. 21.8%). In subcutaneous venous access, infections were confirmed in 5% in HURYC vs. 1.2% in HUGM. There were occlusions at least once in 10% in HUGM and no other significant complications were detected. Regarding PICC, information was only collected in HURYC, where complications were phlebitis 10.8%, thrombosis 7.7%, confirmed or suspected infection 4.6%, occlusion at least once 7.7%. Differences between hospitals with regard to major complications, infection and occlusion may be related to different care protocol. We need to stress the high incidence of phlebitis and thrombosis in PICC catheters, compared with data of lower incidence of other papers. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  14. Post-General Anesthesia Ultrasound-Guided Venous Mapping Increases Autogenous Access Placement Rates.

    Science.gov (United States)

    Png, C Y Maximilian; Korayem, Adam; Finlay, David J

    2018-04-18

    between the groups in terms of outpatient vein mapping plans (P=0.10), however when comparing the PAUS plans to the outpatient vein mapping plans, there was again a significantly increased proportion of preferred access types in the PAUS group compared to the outpatient group (P<0.001). In the ordinal logit multivariate analysis, the only significant variable was the post-anesthesia ultrasound, which positively correlated with more favorable access configurations (coefficient=2.61, P<0.001). The bivariate logit regression for autogenous access maturation rates found no significant difference between the without-PAUS group and the PAUS group (P=0.13). Introducing a post-anesthesia ultrasound mapping to guide vein-finding significantly increases the quality and quantity of suitable veins found, subsequently leading to increased proportions preferred access placement (autogenous vs. prosthetic and forearm vs. upper extremity). Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Clinical study of the Erlanger silver catheter--data management and biometry.

    Science.gov (United States)

    Martus, P; Geis, C; Lugauer, S; Böswald, M; Guggenbichler, J P

    1999-01-01

    The clinical evaluation of venous catheters for catheter-induced infections must conform to a strict biometric methodology. The statistical planning of the study (target population, design, degree of blinding), data management (database design, definition of variables, coding), quality assurance (data inspection at several levels) and the biometric evaluation of the Erlanger silver catheter project are described. The three-step data flow included: 1) primary data from the hospital, 2) relational database, 3) files accessible for statistical evaluation. Two different statistical models were compared: analyzing the first catheter only of a patient in the analysis (independent data) and analyzing several catheters from the same patient (dependent data) by means of the generalized estimating equations (GEE) method. The main result of the study was based on the comparison of both statistical models.

  16. Urinary catheter - infants

    Science.gov (United States)

    Bladder catheter - infants; Foley catheter - infants; Urinary catheter - neonatal ... A urinary catheter is a small, soft tube placed in the bladder. This article addresses urinary catheters in babies. WHY IS ...

  17. Implementation of the updated 2015 Commission for Hospital Hygiene and Infection Prevention (KRINKO recommendations “Prevention and control of catheter-associated urinary tract infections” in the hospitals in Frankfurt/Main, Germany

    Directory of Open Access Journals (Sweden)

    Heudorf, Ursel

    2016-06-01

    Full Text Available Aim: The Commission for Hospital Hygiene and Infection Prevention (KRINKO updated the recommendations for the prevention of catheter-associated urinary tract infections in 2015. This article will describe the implementation of these recommendations in Frankfurt’s hospitals in autumn, 2015.Material and methods: In two non-ICU wards of each of Frankfurt’s , inspections were performed using a checklist based on the new KRINKO recommendations. In one large hospital, a total of were inspected. The inspections covered the structure and process quality (operating instructions, training, indication, the placement and maintenance of catheters and the demonstration of the preparation for insertion of a catheter using an empty bed and an imaginary patient, or insertion in a model.Results: Operating instructions were available in all hospital wards; approximately half of the wards regularly performed training sessions. The indications were largely in line with the recommendations of the KRINKO. Alternatives to urinary tract catheters were available and were used more often than the urinary tract catheters themselves (15.9% vs. 13.5%. In accordance with the recommendations, catheters were placed without antibiotic prophylaxis or the instillation of antiseptic or antimicrobial substances or catheter flushing solutions. The demonstration of catheter placement was conscientiously performed. Need for improvement was seen in the daily documentation and the regular verification of continuing indication for a urinary catheter, as well as the omission of regular catheter change.Conclusion: Overall, the recommendations of the KRINKO on the prevention of catheter-associated urinary tract infections were adequately implemented. However, it cannot be ruled out that in situations with time pressure and staff shortage, the handling of urinary tract catheters may be of lower quality than that observed during the inspections, when catheter insertion was done by two

  18. The Initial Vascular Access Type Contributes to Inflammation in Incident Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Mala Sachdeva

    2012-01-01

    Full Text Available Background. The contribution of the hemodialysis (HD vascular access type to inflammation is unclear. Methods. We conducted a prospective observational study in an incident HD population. C-reactive protein (CRP, interleukin-6 (IL-6, and interferon-γ-induced protein (IP-10 were measured before and at 6-time points after access placement for 1 year. Results. Sixty-four incident HD patients were included (tunneled catheter (TC, =40, arteriovenous fistula (AVF, =14, and arteriovenous graft (AVG, =10. A mixed effects model was performed to adjust for age, sex, race, coronary artery disease, diabetes mellitus, infections, access thrombosis, initiation of HD, and days after access surgery. In comparison to AVFs, the presence of a TC was associated with significantly higher levels of CRP (=0.03, IL-6 (=0.07, and IP-10 (=0.03. The presence of an AVG was associated with increases in CRP (=0.01 and IP-10 (=0.07. Conclusions. Patients who initiate HD with a TC or an AVG have a heightened state of inflammation, which may contribute to the excess 90-day mortality after HD initiation.

  19. Peripheral Insertion of a Central Venous Access Device Under Fluoroscopic Guidance Using a Peripherally Accessed System (PAS) Port in the Forearm

    International Nuclear Information System (INIS)

    Hata, Yasuhiro; Morita, Sojiro; Morita, Yoshitaka; Awatani, Toshihide; Takasaki, Motohiro; Horimi, Tadashi; Ozawa, Zen

    1998-01-01

    Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm. Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route. Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred. Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis

  20. Does interscalene catheter placement with stimulating catheters improve postoperative pain or functional outcome after shoulder surgery? A prospective, randomized and double-blinded trial

    NARCIS (Netherlands)

    Stevens, Markus F.; Werdehausen, Robert; Golla, Elisabeth; Braun, Sebastian; Hermanns, Henning; Ilg, Ansgar; Willers, Reinhardt; Lipfert, Peter

    2007-01-01

    BACKGROUND: In this prospective, randomized, double-blind trial we investigated the use of stimulating catheters in patients during and after shoulder surgery; functional improvement being the primary outcome measurement. METHODS: After eliciting an adequate muscular twitch at

  1. Variables decreasing tip movement of peripherally inserted central catheters in pediatric patients.

    Science.gov (United States)

    Gnannt, Ralph; Connolly, Bairbre L; Parra, Dimitri A; Amaral, Joao; Moineddin, Rahim; Thakor, Avnesh S

    2016-10-01

    The position of the tip of a peripherally inserted central catheter (PICC) is crucial; malposition can lead to malfunction of the line or life-threatening events (e.g., arrhythmias, perforation). To determine what factors other than arm position and accessed vein might influence the tip position of a PICC. Inclusion criteria were upper limb PICC placement, body weight central tip movement in rib units. We included 112 children who received a PICC (42 girls/70 boys, mean age 31±13 months, mean weight 6.5±4.9 kg). The overall range of central tip movement was -1 to +4 rib units (mean +0.8±0.7 rib units). Silicone PICCs moved significantly less than polyurethane PICCs (Pcentral tip movement of a PICC (P>0.05). Silicone PICCs and PICCs inserted into the cephalic vein move less than PICCs made of polyurethane and PICCs inserted into the brachial and basilic veins. These findings might assist operators in deciding which PICC to place in children in a given clinical context.

  2. A new Subcutaneously Anchored Device for Securing External Cerebrospinal Fluid Catheters: our Preliminary Experience.

    Science.gov (United States)

    Frassanito, Paolo; Massimi, Luca; Tamburrini, Gianpiero; Pittiruti, Mauro; Doglietto, Francesco; Nucci, Carlotta Ginevra; Caldarelli, Massimo

    2016-09-01

    Accidental dislocation or removal is a well-known complication of external cerebrospinal fluid (CSF) drainage in daily clinical practice. At present, no data about the incidence of such complications are available in the scientific literature. SecurAcath (Interrad Medical, Plymouth, Minnesota, USA) is a subcutaneously anchored device recently adopted for securement of central venous catheters, known to be highly effective (and cost-effective) in reducing the risk of catheter dislodgement and/or accidental removal. We report our preliminary experience with the use of SecurAcath to secure CSF drainage, either ventricular or spinal, to the skin. SecurAcath was used in 29 consecutive patients (age range: 3 weeks-16 years, median age 6.3 years). In particular, the device was used for 25 ventricular catheters (a patient received 2 catheters in the same procedure for bilateral brain abscess) and 5 spinal drainages. Period in place ranged from 1-4 weeks (median 22 days). No complication related to the use of the device was observed, in particular there was no case of dislocation or accidental removal of the catheter. The removal procedure was extremely easy. The device has proven its utility also in 3 cases requiring an adjustment of the length of the catheter. In our experience, SecurAcath is a safe and effective device to secure CSF external catheters to the skin, with several relevant advantages: its placement and maintenance are easy; it may stay in place for the entire duration of the catheter; it allows a more complete antisepsis of the exit site, thus reducing local skin complications; it eliminates the risk of suture-related needlestick injuries. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Combined ultrasound and fluoroscopy guided port catheter implantation-High success and low complication rate

    International Nuclear Information System (INIS)

    Gebauer, Bernhard; El-Sheik, Michael; Vogt, Michael; Wagner, Hans-Joachim

    2009-01-01

    Purpose: To evaluate peri-procedural, early and late complications as well as patients' acceptance of combined ultrasound and fluoroscopy guided radiological port catheter implantation. Materials and methods: In a retrospective analysis, all consecutive radiological port catheter implantations (n = 299) between August 2002 and December 2004 were analyzed. All implantations were performed in an angio suite under analgosedation and antibiotic prophylaxis. Port insertion was guided by ultrasonographic puncture of the jugular (n = 298) or subclavian (n = 1) vein and fluoroscopic guidance of catheter placement. All data of the port implantation had been prospectively entered into a database for interventional radiological procedures. To assess long-term results, patients, relatives or primary physicians were interviewed by telephone; additional data were generated from the hospital information system. Patients and/or the relatives were asked about their satisfaction with the port implantion procedure and long-term results. Results: The technical success rate was 99% (298/299). There were no major complications according to the grading system of SIR. A total of 23 (0.33 per 1000 catheter days) complications (early (n = 4), late (n = 19)) were recorded in the follow-period of a total of 72,727 indwelling catheter days. Infectious complications accounted for 0.15, thrombotic for 0.07 and migration for 0.04 complications per 1000 catheter days. Most complications were successfully treated by interventional measures. Twelve port catheters had to be explanted due to complications, mainly because of infection (n = 9). Patients' and relatives' satisfaction with the port catheter system was very high, even if complications occurred. Conclusion: Combined ultrasound and fluoroscopy guided port catheter implantation is a very safe and reliable procedure with low peri-procedural, early and late complication rate. The intervention achieves very high acceptance by the patients and

  4. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  5. Managing malignant pleural effusion with an indwelling pleural catheter: factors associated with spontaneous pleurodesis.

    Science.gov (United States)

    Wong, W M; Tam, T Cc; Wong, M Ky; Lui, M Ms; Ip, M Sm; Lam, D Cl

    2016-08-01

    Malignant pleural effusion can be recurrent despite active anti-cancer treatment. Significant malignant pleural effusion leads to debilitating dyspnoea and worsening quality of life in patients with advanced cancer. An indwelling pleural catheter offers a novel means to manage recurrent malignant pleural effusion and may remove the need for repeated thoracocentesis. Spontaneous pleurodesis is another unique advantage of indwelling pleural catheter placement but the factors associated with its occurrence are not clearly established. The aims of this study were to explore the safety of an indwelling pleural catheter in the management of symptomatic recurrent malignant pleural effusion, and to identify the factors associated with spontaneous pleurodesis. This case series with internal comparisons was conducted in the Division of Respiratory Medicine, Department of Medicine, Queen Mary Hospital, Hong Kong. All patients who underwent insertion of an indwelling pleural catheter from the initiation of such service from January 2010 to December 2014 were included for data analysis. Patients were monitored until December 2014, with the last catheter inserted in July 2014. Between 2010 and 2014, a total of 23 indwelling pleural catheters were inserted in 22 consecutive patients with malignant pleural effusion, including 15 (65.2%) cases with malignant pleural effusion as a result of metastatic lung cancer. Ten (43.5%) cases achieved minimal output according to defined criteria, in five of whom the pleural catheter was removed without subsequent re-accumulation of effusion (ie spontaneous pleurodesis). Factors associated with minimal output were the absence of trapped lung (P=0.036), shorter time from first appearance of malignant pleural effusion to catheter insertion (P=0.017), and longer time from catheter insertion till patient's death or end of study (P=0.007). An indwelling pleural catheter provides a safe means to manage symptomatic malignant pleural effusion

  6. Central Venous Catheter-related Fungemia Caused by Rhodotorula glutinis.

    Science.gov (United States)

    Miglietta, Fabio; Letizia Faneschi, Maria; Braione, Adele; Palumbo, Claudio; Rizzo, Adriana; Lobreglio, Giambattista; Pizzolante, Maria

    2015-01-01

    Bloodstream infection due to Rhodotorula glutinis is extremely rare and mostly associated with underlying immunosuppression or cancer. Vascular access devices provide the necessary surfaces for biofilm formation and are currently responsible for a significant percentage of human infections. In this work, we describe a rare case of central venous catheter-related Rhodotorula glutinis fungemia in a female patient with acute myelogenous leukemia in remission. The timely removal of central venous catheter was an essential element for overcoming this CVC-related Rhodotorula fungemia.

  7. Exchanging Catheters Over a Single Transseptal Sheath During Left Atrial Ablation is Associated with a Higher Risk for Silent Cerebral Events

    Directory of Open Access Journals (Sweden)

    Thomas Deneke, MD

    2014-09-01

    Conclusions: Exchanging catheters over a single transseptal access to perform left atrial ablation is associated with a significantly higher incidence of SCE compared to an ablation technique using different transseptal accesses for therapeutic and diagnostic catheters.

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  11. Transurethral Bougie-guided Placement of Suprapubic Catheter Over Guide Wire Monorail in Females: A Novel Technique.

    Science.gov (United States)

    Dalela, Divakar; Gupta, Piyush; Dalela, Disha; Srinivas, A K; Bhaskar, Ved; Govil, Tuhina; Goel, Apul; Sankhwar, Satya Narayan

    2016-08-01

    To assess the safety and effectiveness of a novel transurethral bougie-guided monorail technique for suprapubic catheterization in females with vesicovaginal fistula. Patients undergoing transvaginal vesicovaginal fistula repair from February 2013 to December 2013 were selected. Suprapubic catheter was placed using this technique and assessment was done in terms of time taken, intraprocedural dislodgement or entanglement of catheter during the procedure, bleeding from the anterior abdominal wall or urethra, or any other intraoperative difficulty. All patients were catheterized smoothly without any intraoperative difficulty, with a mean time of 6 minutes. We describe a new technique of performing suprapubic cystostomy in patients, especially where the bladder cannot be distended. It is safe and easy to perform. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  13. Clinical evaluation of the use of an intracardiac electrocardiogram to guide the tip positioning of peripherally inserted central catheters.

    Science.gov (United States)

    Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang

    2016-06-01

    The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.

  14. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  15. Does the Implantation Technique for Totally Implantable Venous Access Ports (TIVAPs) Influence Long-Term Outcome?

    Science.gov (United States)

    Biacchi, Daniele; Sammartino, Paolo; Sibio, Simone; Accarpio, Fabio; Cardi, Maurizio; Sapienza, Paolo; De Cesare, Alessandro; Atta, Joseph Maher Fouad; Impagnatiello, Alessio; Di Giorgio, Angelo

    2016-02-01

    Totally implantable venous access ports (TIVAP) are eventually explanted for various reasons, related or unrelated to the implantation technique used. Having more information on long-term explantation would help improve placement techniques. From a series of 1572 cancer patients who had TIVAPs implanted in our center with the cutdown technique or Seldinger technique, we studied the 542 patients who returned to us to have their TIVAP explanted after 70 days or more. As outcome measures we distinguished between TIVAPs explanted for long-term complications (infection, catheter-, reservoir-, and patient-related complications) and TIVAPs no longer needed. Univariate and multivariate analyses were run to investigate the reasons for explantation and their possible correlation with implantation techniques. The most common reason for explantation was infection (47.6 %), followed by catheter-related (20.8 %), patient-related (14.7 %), and reservoir-related complications (4.7 %). In the remaining 12.2 % of cases, the TIVAP was explanted complication free after the planned treatments ended. Infection correlated closely with longer TIVAP use. Univariate and multivariate analyses identified the Seldinger technique as a major risk factor for venous thrombosis and catheter dislocation. The need for long-term TIVAP explantation in about one-third of cancer patients is related to the implantation techniques used.

  16. Predictors of nonfunctional arteriovenous access at hemodialysis initiation and timing of access creation: A registry-based study.

    Directory of Open Access Journals (Sweden)

    Natalia Alencar de Pinho

    Full Text Available Determinants of nonfunctional arteriovenous (AV access, including timing of AV access creation, have not been sufficiently described. We studied 29 945 patients who had predialysis AV access placement and were included in the French REIN registry from 2005 through 2013. AV access was considered nonfunctional when dialysis began with a catheter. We estimated crude and adjusted odds ratio (OR with 95% confidence intervals (CI of nonfunctional versus functional AV access associated with case-mix, facility characteristics, and timing of AV access creation. Analyses were stratified by dialysis start condition (planned or as an emergency and comorbidity profile. Overall, 18% patients had nonfunctional AV access at hemodialysis initiation. In the group with planned dialysis start, female gender (OR 1.43, 95% CI 1.32-1.56, diabetes (OR 1.28, 95% CI 1.15-1.44, and a higher number of cardiovascular comorbidities (OR 1.27, 95% CI 1.09-1.49, and 1.31, 1.05-1.64, for 3 and >3 cardiovascular comorbidities versus none, respectively were independent predictors of nonfunctional AV access. A higher percentage of AV access creation at the region level was associated with a lower rate of nonfunctional AV access (OR 0.98, 95% CI 0.98-0.99 per 1% increase. The odds of nonfunctional AV access decreased as time from creation to hemodialysis initiation increased up to 3 months in nondiabetic patients with fewer than 2 cardiovascular comorbidities and 6 months in patients with diabetes or 2 or more such comorbidities. In conclusion, both patient characteristics and clinical practices may play a role in successful AV access use at hemodialysis initiation. Adjusting the timing of AV access creation to patients' comorbidity profiles may improve functional AV access rates.

  17. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    Science.gov (United States)

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  18. Hickman catheter embolism in a child during stem cell transplantation

    International Nuclear Information System (INIS)

    Ahmed, P.; Khan, B.; Ullah, K.; Ahmed, W.; Hussain, I.; Khan, A.A.; Anwar, M.

    2003-01-01

    The majority of stem cell recipients rely on indwelling central venous catheters situated in superior vena cava or right atrium. Semi-permanent tunneled silicone rubber Hickman catheters are widely used to provide durable central venous access for patients undergoing stem cell transplantation. A case of 5 years old child with diagnosis of severe aplastic anemia is reported. The patient received peripheral blood stem cells (PBSC) and had successful engraftment with complete hematological recovery. He had Hickman catheter embolism in the pulmonary circulation following unsuccessful attempt to remove the line. The catherter was successfully removed by midsternostomy operation. The child is normal with sustained remission on day +218 post stem cell transplant. (author)

  19. Use of wound soaker catheters for the administration of local anesthetic for post-operative analgesia: 56 cases.

    Science.gov (United States)

    Abelson, Amanda L; McCobb, Emily C; Shaw, Scott; Armitage-Chan, Elizabeth; Wetmore, Lois A; Karas, Alicia Z; Blaze, Cheryl

    2009-11-01

    To describe the administration of local anesthetic through wound soaker catheters for post-operative veterinary patients and to characterize complications. Retrospective study of hospital records. Records of patients in which a wound soaker catheter was placed post-operatively between November 1, 2004 and July 1, 2006 at a veterinary teaching hospital. Records in which a limb amputation was performed between January 1, 2002 and August 1, 2007 and in which a wound soaker catheter was not placed were reviewed for historic control. A total of 56 cases were identified in which a wound soaker catheter was placed post-operatively including 52 dogs, 2 cats, and 2 goats. Twenty canine cases were identified in which limb amputation was performed and no wound soaker catheter was placed. The majority of surgical procedures for which a wound soaker catheter was placed included thoracic limb amputation (46.4%) and pelvic limb amputation (35.7%). Wound soaker catheters remained in place for an average of 1.6 +/- 0.5 days. Feline and caprine patients received intermittent bupivacaine boluses every 6 hours. Canine patients received continuous lidocaine infusions. Complications included disconnection of the catheter from the infusion (7.7%), one seroma, and one suspected lidocaine neurotoxicity. Incisional infections were noted in 3/56 (5.3%) limb amputations with wound soaker catheters placed which was not higher than the incisional infection rate found in the historic control cases 3/20 (15%). Use of the wound soaker catheter was a viable means of providing local analgesia in post-operative veterinary patients. Studies are needed to evaluate efficacy of pain management, and to further investigate techniques for catheter placement and maintenance which may help to optimize the analgesia achieved using this technique.

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... lessen your anxiety during the procedure. The area of the groin or arm where the catheter will be inserted is shaved, ... contrast material is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is ...

  1. Vascular access for home haemodialysis.

    Science.gov (United States)

    Al Shakarchi, Julien; Day, C; Inston, N

    2018-03-01

    Home haemodialysis has been advocated due to improved quality of life. However, there are very little data on the optimum vascular access for it. A retrospective cohort study was carried on all patients who initiated home haemodialysis between 2011 and 2016 at a large university hospital. Access-related hospital admissions and interventions were used as primary outcome measures. Our cohort consisted of 74 patients. On initiation of home haemodialysis, 62 individuals were using an arteriovenous fistula as vascular access, while the remaining were on a tunnelled dialysis catheter. Of the 12 patients who started on a tunnelled dialysis catheter, 5 were subsequently converted to either an arteriovenous fistula ( n = 4) or an arteriovenous graft ( n = 1). During the period of home haemodialysis use, four arteriovenous fistula failed or thrombosed with patients continuing on home haemodialysis using an arteriovenous graft ( n = 3) or a tunnelled dialysis catheter ( n = 1). To maintain uninterrupted home haemodialysis, interventional rates were 0.32 per arteriovenous fistula/arteriovenous graft access-year and 0.4 per tunnelled dialysis catheter access-year. Hospital admission rates for patients on home haemodialysis were 0.33 per patient-year. Our study has shown that home haemodialysis can be safely and independently performed at home within a closely managed home haemodialysis programme. The authors also advocate the use of arteriovenous fistulas for this cohort of patients due to both low complication and intervention rates.

  2. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  3. Catheter Related Blood Stream Infections In Patients Of The Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Ana Carolina Coimbra de Castro

    2017-07-01

    Full Text Available Objective: To identify the prevalence of bloodstream infection associated with the Catheter related Blood stream infections in patients of the Intensive Care Unit, and the characteristics of its use and handling. Methods: Descriptive and transversal study with a sample of 88 participants. Data were collected through the observational method and the records in the medical records. The absolute and relative frequencies were used for data analysis. Results: 73.86% of the patients had central venous access in the subclavian vein, 100% used double lumen Catheter related Blood stream infections, 0.5% chlorhexidine solution for skin antisepsis, dressing coverage is performed mostly with Sterile gauze and tape, with a daily exchange. The rate of infection related to the use of the Catheter related Blood stream infections was (6.81%. The most infused pharmacological drugs were antimicrobials (69.32%. Conclusion: The study showed that care with central venous accesses is performed according to recommendations for prevention of bloodstream infection related to the use of these devices. The infection rate is close to the standards found in the literature. Key words: Central Venous Catheterization. Hospital Infection. Intensive care unit. Risk factors. Catheter-Related Infection..

  4. Radiological management of patients with urinary obstruction following urinary diversion procedures: technical factors, complications, long-term management and outcome. Experience with 378 procedures.

    LENUS (Irish Health Repository)

    Maher, M M

    2012-02-03

    We aimed to assess management by interventional radiology techniques of patients with urinary diversion procedures (UD) complicated by urinary obstruction (UO). A 12-year electronic database of interventional cases was searched for urinary access in patients with UD. Patients\\' records were assessed for aetiology of obstruction, indication for procedure, types of interventional radiology, complications and outcome. Management issues included frequency of visits for catheter care, type of catheter placement and technical problems associated with catheter maintenance. Three hundred and seventy eight procedures were carried out in 25 patients (mean age 70 years; Male : Female ratio 13:12). Indications for UD were malignancy (n = 22) and neuropathic bladder (n = 3). UD included ileal conduits (n = 17), cutaneous ureterostomy (n = 3 (2 patients)) and sigmoid colon urinary conduit (n = 6). In most patients, catheters were placed antegradely through nephrostomy tract, but subsequent access was through the UD. Twenty of 25 patients had unilateral stents where as 5 had bilateral stents (8-10- Fr pigtail catheters (20-45 cm in length)). The mean number of procedures including catheter changes was 15 +\\/- 4 per patient and 331 of 378 procedures (87 %) were carried out as outpatients. Since catheter placement, 11 patients required hospital admission on 22 occasions for catheter-related complications. Ureteric strictures in patients with UD can be successfully managed by interventional radiology.

  5. Report of the unannounced monitoring assessment at University Hospital Limerick

    LENUS (Irish Health Repository)

    Maher, M M

    2012-02-03

    We aimed to assess management by interventional radiology techniques of patients with urinary diversion procedures (UD) complicated by urinary obstruction (UO). A 12-year electronic database of interventional cases was searched for urinary access in patients with UD. Patients\\' records were assessed for aetiology of obstruction, indication for procedure, types of interventional radiology, complications and outcome. Management issues included frequency of visits for catheter care, type of catheter placement and technical problems associated with catheter maintenance. Three hundred and seventy eight procedures were carried out in 25 patients (mean age 70 years; Male : Female ratio 13:12). Indications for UD were malignancy (n = 22) and neuropathic bladder (n = 3). UD included ileal conduits (n = 17), cutaneous ureterostomy (n = 3 (2 patients)) and sigmoid colon urinary conduit (n = 6). In most patients, catheters were placed antegradely through nephrostomy tract, but subsequent access was through the UD. Twenty of 25 patients had unilateral stents where as 5 had bilateral stents (8-10- Fr pigtail catheters (20-45 cm in length)). The mean number of procedures including catheter changes was 15 +\\/- 4 per patient and 331 of 378 procedures (87 %) were carried out as outpatients. Since catheter placement, 11 patients required hospital admission on 22 occasions for catheter-related complications. Ureteric strictures in patients with UD can be successfully managed by interventional radiology.

  6. Training of nurses on Foley catheter insertion in intensive care unit patients: limits and possibilities

    Directory of Open Access Journals (Sweden)

    Magno Conceição Merces

    2013-04-01

    Full Text Available Backgound and Objectives: Nursing has an important role in urinary tract infection prevention and control. Urinary catheters insertion represents the local topography with the highest rate of hospital infection. Foley catheter placement is performed solely by the nurse and requires aseptic techniques during its performance, thus preventing risks to the patients. The study aimed to evaluate the training of nurses on Foley catheter insertion and point out limits and possibilities of this practice in patients at the Intensive Care Unit (ICU of Hospital Geral do Interior da Bahia (HGIB. Methods: This was a qualitative, exploratory and descriptive study. Data collection was carried out through semi-structured interviews. After data analysis, two categories were evaluated, namely: the training of nurses on Foley catheter insertion in ICU patients and the limits and possibilities of Foley catheter insertion practice by nurses in ICU patients. Bardin analysis was used for data analysis. Results: The study shows that the nurse’s practice on Foley catheter insertion in ICU patients is based on the use of aseptic techniques for urinary tract infection prevention, theoretical and practical knowledge on Foley catheter insertion in ICU patients, knowledge on urinary tract infections and associations with catheter insertion, whereas the limits and possibilities of Foley catheter insertion practice by nurses are understood through measures to minimize the risk of hospital infection caused by long-term catheter use in the ICU. Nurses point out that the risks of hospital infection are inherent to long-term catheter use. This is an important fact, as the knowledge or its absence may constitute a limit or possibility for Foley catheter insertion practice by the nurse in ICU patients. Conclusion: Nurses must seek the systematization of knowledge, which warrants support for the team, as well as information, safety and prompt care, allowing the reduction of urinary

  7. Closure Using a Surgical Closure Device of Inadvertent Subclavian Artery Punctures During Central Venous Catheter Placement

    International Nuclear Information System (INIS)

    Berlet, Matthew H.; Steffen, Diana; Shaughness, George; Hanner, James

    2001-01-01

    Severe complications can and do occur when central venous catheters are inadvertently placed into subclavian arteries. Two cases are discussed that describe how these inadvertent arterial punctures can be closed using the Perclose device (Abbott Laboratories, Redwood City, CA, USA)

  8. Tunneled dialysis catheter exchange with fibrin sheath disruption is not associated with increased rate of bacteremia.

    Science.gov (United States)

    Valliant, Amanda M; Chaudhry, Muhammad K; Yevzlin, Alexander S; Astor, Brad; Chan, Micah R

    2015-01-01

    Tunneled dialysis catheters are the most common form of vascular access among incident dialysis patients in the United States. Fibrin sheath formation is a frequent cause of late catheter dysfunction requiring an exchange procedure with balloon disruption of the fibrin sheath. It is unknown whether fibrin sheath disruption is associated with increased incidence of bacteremia or catheter failure. We reviewed all tunneled dialysis catheter exchange procedures at the University of Wisconsin between January 2008 and December 2011. The primary outcome was incidence of bacteremia, defined as positive blood cultures within 2 weeks of the procedure. Catheter failure, requiring intervention or replacement, was examined as a secondary outcome. Baseline characteristics examined included diabetic status, gender, race and age. A total of 163 procedures were reviewed; 67 (41.1%) had fibrin sheath disruption and 96 did not. Bacteremia occurred in 4.5% (3/67) of those with and 3.1% (3/97) of those without fibrin sheath disruption (p=0.65). Fibrin sheath disruption was not significantly associated with the risk of catheter failure (adjusted hazard ratio [aHR]=1.34; 95% confidence interval [CI]: 0.87-2.10; p=0.18). Diabetes was associated with greater risk of catheter failure (aHR=1.88; 95% CI: 1.19-2.95; p=0.006), whereas higher age was associated with a lower risk of catheter failure (aHR per 10 years=0.83; 95% CI: 0.72-0.96; p=0.01). This study demonstrates that there is no significant increase in bacteremia and subsequent catheter dysfunction rates after fibrin sheath disruption compared to simple over the wire exchange. These results are encouraging given the large numbers of patients utilizing tunneled catheters for initial hemodialysis access and the known rates of fibrin sheath formation leading to catheter failure.

  9. Placement of a Retrievable Guenther Tulip Filter in the Superior Vena Cava for Upper Extremity Deep Venous Thrombosis

    International Nuclear Information System (INIS)

    Nadkarni, Sanjay; Macdonald, Sumaira; Cleveland, Trevor J.; Gaines, Peter A.

    2002-01-01

    A retrievable Guenther Tulip caval filter(William Cook, Europe) was successfully placed and retrieved in the superior vena cava for upper extremity deep venous thrombosis in a 56-year-old woman. Bilateral subclavian and internal jugular venous thromboses thought secondary to placement of multiple central venous catheters were present. There have been reports of the use of permanent Greenfield filters and a single case report of a temporary filter in the superior vena cava. As far as we are aware this is the first reported placement and successful retrieval of a filter in these circumstances

  10. Does Guidewire Exchange Influence Infection Rate Related to Catheters Used for Vascular Access in Children on Chronic Hemodialysis?

    Science.gov (United States)

    Rus, Rina R; Battelino, Nina; Ponikvar, Rafael; Premru, Vladimir; Novljan, Gregor

    2017-02-01

    A central venous catheter (CVC) can either be inserted "de novo" or placed by guidewire exchange (GWE). From September 1998 to September 2015, 32 children (19 boys, 13 girls) were hemodialyzed in our unit by using a CVC. The mean age at CVC insertion was 12.6 ± 0.5 years. A total of 121 uncuffed catheters were placed, either "de novo" or by GWE in 64 (52.9%) and 57 (47.1%) cases, respectively. The most frequent cause for line revision was catheter dysfunction in 40/121 (33.1%) patients. The overall incidence of bacteremia was 1.5/1000 catheter-days. The incidence in newly inserted and GWE catheters was 1.4 and 1.7/1000 catheter-days, respectively. The difference did not reach statistical significance (P = 0.939). The infection rate correlated with patient age, and was higher in younger children (P = 0.006). GWE is an effective option of line revision, and did not influence the infection rate in our study. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  11. PEG Tube Placement

    Directory of Open Access Journals (Sweden)

    Saptarshi Biswas

    2014-01-01

    Full Text Available Percutaneous endoscopic gastrostomy (PEG has been used for providing enteral access to patients who require long-term enteral nutrition for years. Although generally considered safe, PEG tube placement can be associated with many immediate and delayed complications. Buried bumper syndrome (BBS is one of the uncommon and late complications of percutaneous endoscopic gastrostomy (PEG placement. It occurs when the internal bumper of the PEG tube erodes into the gastric wall and lodges itself between the gastric wall and skin. This can lead to a variety of additional complications such as wound infection, peritonitis, and necrotizing fasciitis. We present here a case of buried bumper syndrome which caused extensive necrosis of the anterior abdominal wall.

  12. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis, MD, FESC, FACC, FHRS

    2018-01-01

    Full Text Available Background: Cardiac resynchronization therapy (CRT device implantation is hampered by difficult placement of the left ventricular (LV lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. Methods: The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63, cardiomyopathy (n=72, or other disease (n=3, and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P (n=33 and cardioverter defibrillators (CRT-D (n=105. Results: Using the electrophysiology catheter, the CS could be engaged in 134 (97.1% patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2 or conventional (n=1 systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2 or removed because of local dissection (n=1. Thus, finally, a CRT system was successfully established in 131 (94.9% patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months, clinical improvement was reported by 108 (82.4% patients. Conclusion: Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation. Keywords: heart failure, cardiac resynchronization therapy, implantable cardioverter defibrillator, coronary sinus, left ventricular lead

  13. GuideLiner™ as guide catheter extension for the unreachable mammary bypass graft.

    Science.gov (United States)

    Vishnevsky, Alec; Savage, Michael P; Fischman, David L

    2018-03-09

    Percutaneous coronary intervention (PCI) of mammary artery bypass grafts through a trans-radial (TR) approach can present unique challenges, including coaxial vessel engagement of the guiding catheter, adequate visualization of the target lesion, sufficient backup support for equipment delivery, and the ability to reach very distal lesions. The GuideLiner catheter, a rapid exchange monorail mother-in-daughter system, facilitates successful interventions in such challenging anatomy. We present a case of a patient undergoing PCI of a right internal mammary artery (RIMA) graft via TR access in whom the graft could not be engaged with any guiding catheter. Using a balloon tracking technique over a guidewire, a GuideLiner was placed as an extension of the guiding catheter and facilitated TR-PCI by overcoming technical challenges associated with difficult anatomy. © 2018 Wiley Periodicals, Inc.

  14. Bronchial lumen is the safer route for an airway exchange catheter in double-lumen tube replacement: preventable complication in airway management for thoracic surgery.

    Science.gov (United States)

    Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming

    2017-10-01

    There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.

  15. Ultrasound-Guided Interscalene Catheter Complicated by Persistent Phrenic Nerve Palsy

    Directory of Open Access Journals (Sweden)

    Andrew T. Koogler

    2018-01-01

    Full Text Available A 76-year-old male presented for reverse total shoulder arthroplasty (TSA in the beach chair position. A preoperative interscalene nerve catheter was placed under direct ultrasound-guidance utilizing a posterior in-plane approach. On POD 2, the catheter was removed. Three weeks postoperatively, the patient reported worsening dyspnea with a subsequent chest X-ray demonstrating an elevated right hemidiaphragm. Pulmonary function testing revealed worsening deficit from presurgical values consistent with phrenic nerve palsy. The patient decided to continue conservative management and declined further invasive testing or treatment. He was followed for one year postoperatively with moderate improvement of his exertional dyspnea over that period of time. The close proximity of the phrenic nerve to the brachial plexus in combination with its frequent anatomical variation can lead to unintentional mechanical trauma, intraneural injection, or chemical injury during performance of ISB. The only previously identified risk factor for PPNP is cervical degenerative disc disease. Although PPNP has been reported following TSA in the beach chair position without the presence of a nerve block, it is typically presumed as a complication of the interscalene block. Previously published case reports and case series of PPNP complicating ISBs all describe nerve blocks performed with either paresthesia technique or localization with nerve stimulation. We report a case of a patient experiencing PPNP following an ultrasound-guided placement of an interscalene nerve catheter.

  16. Indwelling catheter care

    Science.gov (United States)

    Foley catheter ... You will need to make sure your indwelling catheter is working properly. You will also need to ... not get an infection or skin irritation. Make catheter and skin care part of your daily routine. ...

  17. Peripheral intravenous and central catheter algorithm: a proactive quality initiative.

    Science.gov (United States)

    Wilder, Kerry A; Kuehn, Susan C; Moore, James E

    2014-12-01

    Peripheral intravenous (PIV) infiltrations causing tissue damage is a global issue surrounded by situations that make vascular access decisions difficult. The purpose of this quality improvement project was to develop an algorithm and assess its effectiveness in reducing PIV infiltrations in neonates. The targeted subjects were all infants in our neonatal intensive care unit (NICU) with a PIV catheter. We completed a retrospective chart review of the electronic medical record to collect 4th quarter 2012 baseline data. Following adoption of the algorithm, we also performed a daily manual count of all PIV catheters in the 1st and 2nd quarters 2013. Daily PIV days were defined as follows: 1 patient with a PIV catheter equals 1 PIV day. An infant with 2 PIV catheters in place was counted as 2 PIV days. Our rate of infiltration or tissue damage was determined by counting the number of events and dividing by the number of PIV days. The rate of infiltration or tissue damage was reported as the number of events per 100 PIV days. The number of infiltrations and PIV catheters was collected from the electronic medical record and also verified manually by daily assessment after adoption of the algorithm. To reduce the rate of PIV infiltrations leading to grade 4 infiltration and tissue damage by at least 30% in the NICU population. Incidence of PIV infiltrations/100 catheter days. The baseline rate for total infiltrations increased slightly from 5.4 to 5.68/100 PIV days (P = .397) for the NICU. We attributed this increase to heightened awareness and better reporting. Grade 4 infiltrations decreased from 2.8 to 0.83/100 PIV catheter days (P = .00021) after the algorithm was implemented. Tissue damage also decreased from 0.68 to 0.3/100 PIV days (P = .11). Statistical analysis used the Fisher exact test and reported as statistically significant at P < .05. Our findings suggest that utilization of our standardized decision pathway was instrumental in providing guidance for

  18. Empyema and Effusion: Outcome of Image-Guided Small-Bore Catheter Drainage

    International Nuclear Information System (INIS)

    Keeling, A. N.; Leong, S.; Logan, P. M.; Lee, M. J.

    2008-01-01

    Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema

  19. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement.

    Science.gov (United States)

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.

  20. Ureteral catheters for colorectal surgery: Influence on operative times and complication outcomes: An observational study

    Directory of Open Access Journals (Sweden)

    Julio T. Chong

    2018-03-01

    Full Text Available Purpose: Placement of pre-operative ureteral catheters for colorectal surgery can aid in the identification of ureteral injuries. This study investigates whether simultaneous ureteral catheterization with surgery skin preparation can minimize operating room times without increasing post-operative complications. Materials and Methods: Patients undergoing simultaneous colorectal surgery skin preparation and placement of pre-operative ureteral catheters (n=21 were compared to those who underwent these events sequentially (n=28. Operative time-points of anesthesia ready (AR, surgery procedure start (PS, dorsal lithotomy and catheter insertion (CI times were compared to assess for differences between groups. Complications were compared between groups. Results: There were no differences in age, gender, body mass index (BMI, American Society of Anesthesiologists (ASA, comorbidities, current procedure terminology (CPT or International Classification of Diseases, 9th revision (ICD-9 codes between groups. Simultaneous catheterization saved 11.82 minutes of operative time between CI to PS (p=0.005, t-test. There was a significant difference in mean time between CI to PS (11.82 minutes, p=0.008 between simultaneous and sequential ureteral catheterization groups in a linear regression multivariate analysis controlling for age, BMI, CPT and ICD-9 codes. There were 4 complications in the simultaneous (19% and 3 in the sequential group (11% (p=0.68. Conclusions: Ureteral catheterization and colorectal surgery skin preparation in a simultaneous fashion decreases the time between CI and PS without significant increase in complications. Mean time saved with simultaneous ureteral catheterization was 11.82 minutes per case. Simultaneous ureteral catheterization may be an option in colorectal surgery and may result in cost savings without additional complications.

  1. Technique to Avoid Hemodialysis Catheter in Patients with Failing Aneurysmal Arteriovenous Fistula by Creating a Concomitant New Arteriovenous Fistula.

    Science.gov (United States)

    Lara, Kelly A; Chua, Rochelle Anne; Vo, Trung D

    2018-05-01

    Autogenous arteriovenous fistula (AVF) is the primary recommended access for hemodialysis. Long-term use will not uncommonly result in AVF aneurysmal degeneration. Aneurysm-associated complications encompass pain, skin ulceration, infection, thrombosis, cannulation difficulties, and life-threatening bleeding. Various methods to repair aneurysmal AVFs have been described. However, there may be circumstances when this is not possible and require insertion of a temporary hemodialysis catheter (HDC) until a new arteriovenous access is created. We describe a case series of creating a new simultaneous AVF while continuing to use the primary failing aneurysmal AVF to avoid placement of an HDC. Once the new AVF becomes operational, the primary aneurysmal AVF can be abandoned. Six patients underwent simultaneous new AVF creation, 4 ipsilateral, and 2 contralateral. None of the patients developed symptomatic steal syndrome or congestive heart failure. Five of 6 patients had successful usage of the new AVF, and subsequently underwent ligation and excision of the aneurysmal AVF, thus avoiding a temporary HDC. Close monitoring for skin compromise and bleeding in the aneurysmal AVF is recommended while the new AVF matures. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Clinical nursing of pelvic neoplasm treated with infusion chemotherapy by using an anti-reflux arterial port-catheter system

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan

    2011-01-01

    Objective: To discuss the clinical nursing care for patients with pelvic neoplasm who were treated with infusion chemotherapy by using an anti-reflux arterial port-catheter system. Methods: After the implantation of an anti-reflux arterial port-catheter system was successfully completed, intra-arterial infusion chemotherapy was carried out in 17 patients with pelvic neoplasm and the infusion chemotherapy was repeated for several times. The pre-procedural clinical nursing care was well done and the technique of proper placement was well grasped. The side effects of chemotherapy drugs and complications were dealt with in time. Medical orientation at discharge time included the protection methods for port-catheter system. Results: Seventeen patients received infusion chemotherapy successfully several times (ranged from 3 to 8 times) with a scheduled regular interval time. No severe complications occurred. No catheter leakage nor obvious irritation and compression symptoms of local skin developed during infusion period. Of the 17 patients, 6 had a complete response, 9 achieved a partial response, while the remaining 2 failed to respond. Conclusion: In accordance with characteristics of infusion chemotherapy by using an anti-reflux arterial port-catheter system, the reasonable and effective nursing care is important to guarantee the achievement of a successful performance and a satisfactory therapeutic result. (authors)

  3. Randomized clinical trial of pigtail catheter versus chest tube in injured patients with uncomplicated traumatic pneumothorax.

    Science.gov (United States)

    Kulvatunyou, N; Erickson, L; Vijayasekaran, A; Gries, L; Joseph, B; Friese, R F; O'Keeffe, T; Tang, A L; Wynne, J L; Rhee, P

    2014-01-01

    Small pigtail catheters appear to work as well as the traditional large-bore chest tubes in patients with traumatic pneumothorax, but it is not known whether the smaller pigtail catheters are associated with less tube-site pain. This study was conducted to compare tube-site pain following pigtail catheter or chest tube insertion in patients with uncomplicated traumatic pneumothorax. This prospective randomized trial compared 14-Fr pigtail catheters and 28-Fr chest tubes in patients with traumatic pneumothorax presenting to a level I trauma centre from July 2010 to February 2012. Patients who required emergency tube placement, those who refused and those who could not respond to pain assessment were excluded. Primary outcomes were tube-site pain, as assessed by a numerical rating scale, and total pain medication use. Secondary outcomes included the success rate of pneumothorax resolution and insertion-related complications. Forty patients were enrolled. Baseline characteristics of 20 patients in the pigtail catheter group were similar to those of 20 patients in the chest tube group. No patient had a flail chest or haemothorax. Pain scores related to chest wall trauma were similar in the two groups. Patients with a pigtail catheter had significantly lower mean(s.d.) tube-site pain scores than those with a chest tube, at baseline after tube insertion (3.2(0.6) versus 7.7(0.6); P pneumothorax, use of a 14-Fr pigtail catheter is associated with reduced pain at the site of insertion, with no other clinically important differences noted compared with chest tubes. NCT01537289 (http://clinicaltrials.gov). © 2013 BJS Society Ltd. Published by John Wiley & Sons Ltd.

  4. Retrograde or antegrade double-pigtail stent placement for malignant ureteric obstruction?

    International Nuclear Information System (INIS)

    Uthappa, M.C.; Cowan, N.C.

    2005-01-01

    AIM: To determine the optimum approach for double-pigtail stent placement in malignant ureteric obstruction. PATIENTS AND METHODS: Retrograde stent placement was attempted in a consecutive series of patients presenting with malignant ureteric obstruction. If retrograde stent placement was unsuccessful, percutaneous nephrostomy was performed immediately followed by elective antegrade stent placement. Identical digital C-arm fluoroscopy for image-guidance and conditions for anaesthesia and analgesia were employed for both retrograde and antegrade procedures. Identical 8 Fr (20-26 cm) double-pigtail hydrophilic coated stents were used for each approach. RESULTS: Retrograde placement was attempted in 50 ureters in 30 patients {19 male, 11 female, average age 61.4 yr (range 29-90 yr)} over a 24-month period. The success rate for retrograde ureteric stent placement was 50% (n=25/50). Technical failures were due to failure to identify the ureteric orifice (n=22), failure to cross the stricture (n=1), failure to pass the stent (n=1) and failure to pass a 4 Fr catheter (n=1). Antegrade placement was attempted in 25 ureters with a success rate of 96% (n=24/25). Failure in the one case was due to inability to cross an upper third stricture secondary to pyeloureteritis cystica. CONCLUSION: It is suggested that retrograde route should be the initial approach if imaging shows no involvement of ureteric orifice (UO), when nephrostomy is technically very difficult or in cases of solitary kidney. The antegrade route is preferred if imaging shows tumour occlusion of the UO or if there is a tight stricture very close to the uretero-vesical junction (UVJ) making purchase within the ureter difficult for crossing the stricture

  5. Umbilical venous catheter malposition and errors in interpretation in newborns with Bochdalek hernia

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Patricia T.; Taylor, George A. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2015-07-15

    Neonates with congenital diaphragmatic hernia (CDH) often require placement of lines and tubes for supportive therapy. The resulting altered anatomy can result in diagnostic errors when interpreting the location of support lines and tubes such as UVCs (umbilical venous catheters). The purpose of this study was to evaluate the effect of CDH on UVC position and to evaluate the accuracy at which radiologists describe the position on chest radiographs. During a 5-year period, 406 chest radiographs performed within 7 days of birth in infants with congenital diaphragmatic hernia were identified and reviewed for the following data: presence of UVC, location of catheter tip (cavoatrial junction, intracardiac, intrahepatic or umbilical vein), and location of CDH (right or left). The radiologic report of the UVC tip location for each case was then reviewed individually to determine the adequacy of interpretation. Inadequate reports were classified as incorrect (the wrong location of the catheter tip was reported), no mention (the location of the catheter tip was in a suboptimal location but not mentioned), and not specified (the precise location of the catheter tip was not clearly stated in the report when the tip was in a suboptimal location). A total of 60 infants were identified as having CDH (56 on the left, 4 on the right). The most common location for an incorrectly placed UVC was the contralateral chest, accounting for 26.7% (16/60) of the infants, followed by an abdominal intrahepatic location (16.7%) and the umbilical vein (8.3%). Thirty percent (120/406) of the chest radiograph reports were found to be inadequate regarding the interpretation of the location of the catheter tip. The majority of the inadequate reports (48/406, 11.8%) did not specify when the catheter tip was in a suboptimal location. In 37 reports (9.1%), the location of the catheter tip was reported incorrectly, and no mention of the catheter location was made in 35 reports (8.6%). The location of

  6. Umbilical venous catheter malposition and errors in interpretation in newborns with Bochdalek hernia

    International Nuclear Information System (INIS)

    Chang, Patricia T.; Taylor, George A.

    2015-01-01

    Neonates with congenital diaphragmatic hernia (CDH) often require placement of lines and tubes for supportive therapy. The resulting altered anatomy can result in diagnostic errors when interpreting the location of support lines and tubes such as UVCs (umbilical venous catheters). The purpose of this study was to evaluate the effect of CDH on UVC position and to evaluate the accuracy at which radiologists describe the position on chest radiographs. During a 5-year period, 406 chest radiographs performed within 7 days of birth in infants with congenital diaphragmatic hernia were identified and reviewed for the following data: presence of UVC, location of catheter tip (cavoatrial junction, intracardiac, intrahepatic or umbilical vein), and location of CDH (right or left). The radiologic report of the UVC tip location for each case was then reviewed individually to determine the adequacy of interpretation. Inadequate reports were classified as incorrect (the wrong location of the catheter tip was reported), no mention (the location of the catheter tip was in a suboptimal location but not mentioned), and not specified (the precise location of the catheter tip was not clearly stated in the report when the tip was in a suboptimal location). A total of 60 infants were identified as having CDH (56 on the left, 4 on the right). The most common location for an incorrectly placed UVC was the contralateral chest, accounting for 26.7% (16/60) of the infants, followed by an abdominal intrahepatic location (16.7%) and the umbilical vein (8.3%). Thirty percent (120/406) of the chest radiograph reports were found to be inadequate regarding the interpretation of the location of the catheter tip. The majority of the inadequate reports (48/406, 11.8%) did not specify when the catheter tip was in a suboptimal location. In 37 reports (9.1%), the location of the catheter tip was reported incorrectly, and no mention of the catheter location was made in 35 reports (8.6%). The location of

  7. [Pain control by continuous infusion of morphine using subarachnoid catheter access to the port--a report of a home death case].

    Science.gov (United States)

    Kawagoe, Koh; Matsuura, Shinobu

    2008-12-01

    This is a case of a 50s male with cecal cancer suffering from severe pain caused by osteolytic metastasis to the lumbar vertebra, right iliac bone, and the head of the right femur. The pain was palliated by continuous infusion of morphine using a subarachnoid catheter that had access to the subcutaneous "Port". The maximum dose of morphine used a day was 384 mg, which corresponded to 57,600 mg/day of oral morphine. Sixty eight days after the start of home hospice care, the patient died at home because of diffuse peritonitis caused by intestinal rupture.

  8. Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart.

    Science.gov (United States)

    Kesner, Samuel B; Howe, Robert D

    2011-01-01

    Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system.

  9. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  10. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-12-01

    Full Text Available Introduction: The PICC (peripherally inserted central catheter is a long flexible catheter which is inserted through a peripheral vein, progresses through a needle introducer until the final portion of the vena cava, acquiring characteristics of a central catheter. Objective: To point out the main theoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses to perform the PICC. Methodology: Systematic review of articles, which were found by searching the database scientific journals and bibliographies area. Results: The success of integration depends on the patient assessment and choice of venous access where the catheter will be positioned, and its tip should be in the middle third of the superior vena cava, or the middle third of the inferior vena cava. In neonates, which are used more frequently, proper positioning of the catheter is through nursing care in making the dressing, and the first 24 hours it should be compressive. Ideally, the PICC remains in the vein for periods longer than seven days or until the end of treatment, thus decreasing invasive procedures. Conclusion: According to the Federal Board of Nursing (COFEN, it is lawful for the insertion of PICC nurses, provided it has undergone professional training.

  11. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  12. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  13. Pediatric central venous access devices: nursing interventions

    Directory of Open Access Journals (Sweden)

    Duffy EA

    2017-05-01

    Full Text Available Elizabeth A Duffy, Kathryn N Nelson Department of Health Behavior and Biological Sciences, The University of Michigan School of Nursing, Ann Arbor, MI, USA Abstract: A central venous catheter (CVC is an indwelling catheter that provides permanent or temporary stable venous access for both acute and chronically ill pediatric patients. These catheters provide stable venous access that can be used for a variety of medical purposes including drawing blood, hemodynamic monitoring, infusion of intravenous medications, infusion of intravenous fluids, chemotherapy, blood products, and parenteral nutrition. Each day, nurses access and care for CVCs in infants, children, and adolescents; the precision of this care can prevent life-threatening complications. The purpose of this review and the case study is to highlight the importance and components of evidence-based nursing practice in pediatric CVC care. A historical perspective of CVC care is provided in conjunction with current national initiatives to improve patient outcomes for children with CVCs. Infection prevention, clinical practice guidelines, quality improvement, and evidence-based care bundles are discussed. Keywords: pediatric nursing, central venous catheters, central line-associated bloodstream infection, care bundles, pediatric case study 

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... incision in the skin. Once the catheter is guided to the area being examined, a contrast material ... inserted into an artery. The catheter is then guided through the arteries to the area to be ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... catheter , is inserted into an artery through a small incision in the skin. Once the catheter is ... the tube and images are captured using a small dose of ionizing radiation ( x-rays ). top of ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... or other procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the ... days. Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  4. Catheter-related bloodstream infection.

    Science.gov (United States)

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  7. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  8. Incidence of thrombosis in children with tunneled central venous access devices versus peripherally inserted central catheters (PICCs).

    Science.gov (United States)

    Kanin, Maralee; Young, Guy

    2013-11-01

    The recent proliferation of deep vein thrombosis in children has been attributed to the increased use of central venous catheters, specifically tunneled lines and peripherally inserted central catheters. A formal comparison of the incidence rate for deep vein thrombosis between tunneled lines and peripherally inserted central catheters has not been undertaken. Children inclusion. Data were extracted from the hospital discharge database which includes data on all procedures and up to 20 diagnoses per admission. Diagnoses and procedures were identified by International Classification of Disease, Ninth Revision coding. Patients were excluded if they received more than one central line. Data collected included type of central line, deep vein thrombosis event, and underlying medical illnesses classified according to chronic complex conditions. Over the seven year study period there was an overall rate of 73 deep vein thromboses per 10,000 hospital discharges. Of the 6915 eligible subjects, 181 had a deep vein thrombosis for an overall incidence rate of 2.6%. There were 152 thrombi (2.6%) in subjects with peripherally inserted central catheters and 29 thrombi (3.1%) in subjects with tunneled lines [OR=.83 (0.55, 1.29), p=0.38]. Despite the relative ease and simplicity of use of peripherally inserted central catheters leading to a substantial rise in their use, this study demonstrates that such lines pose a substantial risk for venous thrombosis and no difference in incidence was detected between such lines and tunneled lines. © 2013.

  9. Conversion from temporary to tunneled catheters by nephrologists: report of a single-center experience

    Directory of Open Access Journals (Sweden)

    Silva BC

    2016-04-01

    Full Text Available Bruno C Silva, Camila E Rodrigues, Regina CRM Abdulkader, Rosilene M Elias Nephrology Division, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil Background: Nephrologists have increasingly participated in the conversion from temporary catheters (TC to tunneled-cuffed catheters (TCCs for hemodialysis. Objective: To prospectively analyze the outcomes associated with TCC placement by nephrologists with expertise in such procedure, in different time periods at the same center. The impact of vancomycin or cefazolin as prophylactic antibiotics on the infection outcomes was also tested. Patients and methods: Hemodialysis patients who presented to such procedure were divided into two cohorts: A (from 2004 to 2008 and B (from 2013 to 2015. Time from TC to TCC conversion, prophylactic antibiotics, and reasons for TCC removal were evaluated. Results: One hundred and thirty patients were included in cohort A and 228 in cohort B. Sex, age, and follow-up time were similar between cohorts. Median time from TC to TCC conversion was longer in cohort A than in cohort B (14 [3; 30] vs 4 [1; 8] days, respectively; P<0.0001. Infection leading to catheter removal occurred in 26.4% vs 18.9% of procedures in cohorts A and B, respectively, and infection rate was 0.93 vs 0.73 infections per 1,000 catheter-days, respectively (P=0.092. Infection within 30 days from the procedure occurred in 1.4% of overall cohort. No differences were observed when comparing vancomycin and cefazolin as prophylactic antibiotics on 90-day infection-free TCC survival in a Kaplan–Meier model (log-rank = 0.188. TCC removal for low blood flow occurred in 8.9% of procedures. Conclusion: Conversion of TC to TCC by nephrologists had overall infection, catheter patency, and complications similar to data reported in the literature. Vancomycin was not superior to cefazolin as a prophylactic antibiotic. Keywords: renal dialysis, tunneled catheters, interventional nephrology

  10. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    International Nuclear Information System (INIS)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-01-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  11. Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.

    Science.gov (United States)

    Ferreira, Janita; Camargos, Paulo Augusto Moreira; Clemente, Wanessa Trindade; Romanelli, Roberta Maia de Castro

    2018-01-01

    Neonatal sepsis is the most frequent health care-associated infection in neonatal units. This study aimed to analyze articles on the clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of intravascular catheter-related bloodstream infection (CRBSI) in neonates. A systematic search was performed for studies published from 1987-2017, without language restriction. Observational studies carried out in neonates with CRBSI diagnosed using catheter-drawn blood samples or catheter tip cultures were included. A total of 412 articles were identified in the databases and 10 articles were included. The 7 studies that evaluated central venous catheter tip cultures and cultures of catheter fragments presented sensitivities ranging from 58.5%-100% and specificities ranging from 60%-95.7%. Three studies that evaluated catheter-drawn blood cultures, paired with peripheral blood cultures, reported sensitivity and specificity of 94% and 71% when evaluated for the differential time to positivity. When quantitative evaluation was performed, the sensitivity and specificity were 80% and 99.4%. Most of the studies analyzed cultures from the central venous catheter tip and catheter fragments for the diagnosis of CRBSI in neonatal populations. The results of this review suggest that the analysis of the catheter-drawn blood samples and catheter tip cultures, paired with peripheral blood cultures, are efficient methods for the diagnosis of CRBSI in neonates. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Ultrasound Thrombolysis in Hemodialysis Access: In Vitro Investigation

    International Nuclear Information System (INIS)

    Wildberger, Joachim Ernst; Schmitz-Rode, Thomas; Haage, Patrick; Pfeffer, Joachim; Ruebben, Alexander; Guenther, Rolf W.

    2001-01-01

    Purpose: To evaluate the effectiveness of ultrasound thrombolysis in occluded hemodialysis access shunts using an in vitro model.Methods: Thrombosed hemodialysis accesses were simulated by clotted bovine blood in a flow model (silicone tubing; inner diameters 4, 6, and 9 mm). After retrograde and antegrade sheath placement (7 Fr), mechanical thrombolysis was performed using an ultrasound probe (Acolysis, Angiosonics, Morrisville, NC, USA). The tip of the device measured 2.2 mm in diameter. During sonication, the catheter was moved slowly back and forth using an over-the-wire system. Thirty complete occlusions [tubing diameters 4 mm (n = 12), 6 mm (n = 12), 9 mm (n = 6)] were treated. Initial thrombus weights were 3.5 (± 0.76) g, 7.7 (± 1.74) g, and 19.4 (± 2.27) g for the three diameters. Maximum sonication time was 15 min for each probe.Results: With this device, we were able to restore a continuous lumen in all 12 occluded 4∼mm silicone tubes. No wall-adherent thrombi remained after sonication for 3.5-9.6 min. In hemodialysis access models with diameters of 6 mm, thrombus fragments persisted in 25% (3/12 accesses). These were located in the medial portion of the access loop and near to the puncture sites. However, flow was re-established after 5.0-13.0 min of treatment in all settings. Mechanical dissolution of thrombus material failed in five of six access models with diameters of 9 mm, even though ultrasound energy was applied for the maximum of 15 min.Conclusion: In a clotted hemodialysis shunt model, successful ultrasound thrombolysis was limited to small access diameters and small amounts of thrombus

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is removed and the incision site is closed by applying pressure on the area for approximately 10 to 20 ...

  14. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  15. Percutaneous pigtail catheter in the treatment of pneumothorax in major burns: the best alternative? Case report and review of literature.

    Science.gov (United States)

    Sebastian, Raul; Ghanem, Omar; Diroma, Frank; Milner, Stephen M; Gerold, Kevin B; Price, Leigh A

    2015-05-01

    Multiple factors place burn patients at a high risk of pneumothorax development. Currently, no specific recommendations for the management of pneumothorax in large total body surface area (TBSA) burn patients exist. We present a case of a major burn patient who developed pneumothorax after central line insertion. After the traditional large bore (24 Fr) chest tube failed to resolve the pneumothorax, the pneumothorax was ultimately managed by a percutaneous placed pigtail catheter thoracostomy placement and resulted in its complete resolution. We will review the current recommendations of pneumothorax treatment and will highlight on the use of pigtail catheters in pneumothorax management in burn patients. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  16. Vascular access choice in incident hemodialysis patients: a decision analysis.

    Science.gov (United States)

    Drew, David A; Lok, Charmaine E; Cohen, Joshua T; Wagner, Martin; Tangri, Navdeep; Weiner, Daniel E

    2015-01-01

    Hemodialysis vascular access recommendations promote arteriovenous (AV) fistulas first; however, it may not be the best approach for all hemodialysis patients, because likelihood of successful fistula placement, procedure-related and subsequent costs, and patient survival modify the optimal access choice. We performed a decision analysis evaluating AV fistula, AV graft, and central venous catheter (CVC) strategies for patients initiating hemodialysis with a CVC, a scenario occurring in over 70% of United States dialysis patients. A decision tree model was constructed to reflect progression from hemodialysis initiation. Patients were classified into one of three vascular access choices: maintain CVC, attempt fistula, or attempt graft. We explicitly modeled probabilities of primary and secondary patency for each access type, with success modified by age, sex, and diabetes. Access-specific mortality was incorporated using preexisting cohort data, including terms for age, sex, and diabetes. Costs were ascertained from the 2010 USRDS report and Medicare for procedure costs. An AV fistula attempt strategy was found to be superior to AV grafts and CVCs in regard to mortality and cost for the majority of patient characteristic combinations, especially younger men without diabetes. Women with diabetes and elderly men with diabetes had similar outcomes, regardless of access type. Overall, the advantages of an AV fistula attempt strategy lessened considerably among older patients, particularly women with diabetes, reflecting the effect of lower AV fistula success rates and lower life expectancy. These results suggest that vascular access-related outcomes may be optimized by considering individual patient characteristics. Copyright © 2015 by the American Society of Nephrology.

  17. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    Science.gov (United States)

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  18. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  19. Surgical insertion of central venous catheters in low-birth-weight ...

    African Journals Online (AJOL)

    Aim: Neonatal central vascular access (CVA) represents a daily practice in neonatal intensive care unit. Low birth weight (LBW) neonates pose a challenge to anesthetists who try the landmark technique to cannulate central veins. We reported our experience of open surgical cutdown (OSC) to insert catheters through right ...

  20. Fluoroscopically guided tunneled trans-caudal epidural catheter technique for opioid-free neonatal epidural analgesia.

    Science.gov (United States)

    Franklin, Andrew D; Hughes, Elisabeth M

    2016-06-01

    Epidural analgesia confers significant perioperative advantages to neonates undergoing surgical procedures but may be very technically challenging to place using a standard interlaminar loss-of-resistance to saline technique given the shallow depth of the epidural space. Thoracic epidural catheters placed via the caudal route may reduce the risk of direct neural injury from needle placement, but often pose higher risks of infection and/or improper positioning if placed without radiographic guidance. We present a detailed method of placing a fluoroscopically guided, tunneled transcaudal epidural catheter, which may reduce both of these risks. The accuracy and precision of this technique often provides adequate analgesia to allow for opioid-free epidural infusions as well as significant reductions in systemic opioids through the perioperative period. Opioid-free analgesia using a regional anesthetic technique allows for earlier extubation and reduced perioperative sedation, which may have a less deleterious neurocognitive effect on the developing brain of the neonate.

  1. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  2. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  3. Endovascular brain intervention and mapping in a dog experimental model using magnetically-guided micro-catheter technology.

    Science.gov (United States)

    Kara, Tomas; Leinveber, Pavel; Vlasin, Michal; Jurak, Pavel; Novak, Miroslav; Novak, Zdenek; Chrastina, Jan; Czechowicz, Krzysztof; Belehrad, Milos; Asirvatham, Samuel J

    2014-06-01

    Despite the substantial progress that has been achieved in interventional cardiology and cardiac electrophysiology, endovascular intervention for the diagnosis and treatment of central nervous system (CNS) disorders such as stroke, epilepsy and CNS malignancy is still limited, particularly due to highly tortuous nature of the cerebral arterial and venous system. Existing interventional devices and techniques enable only limited and complicated access especially into intra-cerebral vessels. The aim of this study was to develop a micro-catheter magnetically-guided technology specifically designed for endovascular intervention and mapping in deep CNS vascular structures. Mapping of electrical brain activity was performed via the venous system on an animal dog model with the support of the NIOBE II system. A novel micro-catheter specially designed for endovascular interventions in the CNS, with the support of the NIOBE II technology, was able to reach safely deep intra-cerebral venous structures and map the electrical activity there. Such structures are not currently accessible using standard catheters. This is the first study demonstrating successful use of a new micro-catheter in combination with NIOBE II technology for endovascular intervention in the brain.

  4. Novel Method for Exchange of Impella Circulatory Assist Catheter: The "Trojan Horse" Technique.

    Science.gov (United States)

    Phillips, Colin T; Tamez, Hector; Tu, Thomas M; Yeh, Robert W; Pinto, Duane S

    2017-07-01

    Patients with an indwelling Impella may require escalation of hemodynamic support or exchange to another circulatory assistance platform. As such, preservation of vascular access is preferable in cases where anticoagulation cannot be discontinued or to facilitate exchange to an alternative catheter or closure device. Challenges exist in avoiding bleeding and loss of wire access in these situations. We describe a single-access "Trojan Horse" technique that minimizes bleeding while maintaining arterial access for rapid exchange of this percutaneous ventricular assist device.

  5. Advanced Placement Academy: Case Study of a Program within a School

    Science.gov (United States)

    Swanson, Julie Dingle; Nagy, Steven

    2014-01-01

    The focus of this study was the first year of implementation of the Advanced Placement Academy (APA), a program within a high school providing honors and Advanced Placement coursework for high-ability African American students with previously limited access to rigorous courses. The qualitative investigation explores practical solutions from…

  6. Comparison of three types of central venous catheters in patients with malignant tumor receiving chemotherapy

    Directory of Open Access Journals (Sweden)

    Fang S

    2017-07-01

    Full Text Available Shirong Fang,1 Jinhong Yang,2 Lei Song,3 Yan Jiang,1 Yuxiu Liu4 1Department of Anesthesiology, 2Department of Oncology, Weifang People’s Hospital, Weifang, 3Intensive Care Unit, The Affiliated Hospital of Qingdao University, Qingdao, 4Nursing College, Weifang Medical University, Weifang, People’s Republic of China Background: Central venous catheters (CVCs have been an effective access for chemotherapy instead of peripherally intravenous catheters. There were limited studies on the choices and effects of different types of CVCs for chemotherapy. The aim of this study was to compare the complications, cost, and patients’ quality of life and satisfaction of three commonly used CVCs for chemotherapy, such as implanted venous port, peripherally inserted central catheters (PICCs, and external non-tunneled central venous catheters (NTCs.Methods: A double-center prospective cohort study was carried out from March 2014 to December 2016. Catheterization situation, complications, catheter maintenance, cost, and patients’ quality of life and satisfaction were recorded, investigated, and analyzed. Forty-five ports, 60 PICCs and 40 NTCs were included. All the CVCs were followed up to catheter removal.Results: There was no statistical difference in catheterization success rates between port and PICC. NTC had less success rate by one puncture compared with port. Ports had fewer complications compared with PICCs and NTCs. The complication rates of ports, PICCs and NTCs were 2.2%, 40%, and 27.5%, respectively. If the chemotherapy process was <12 months, NTCs cost least, and the cost of port was much higher than PICC and NTC. When the duration time was longer than 12 months, the cost of port had no difference with the cost of PICC. Quality of life and patients’ satisfaction of port group were significantly higher than the other two groups. Conclusion: Although port catheterization costs more and needs professional medical staff and strict operational

  7. The efficacy of noble metal alloy urinary catheters in reducing catheter-associated urinary tract infection

    Directory of Open Access Journals (Sweden)

    Alanood Ahmed Aljohi

    2016-01-01

    Results: A 90% relative risk reduction in the rate of CAUTI was observed with the noble metal alloy catheter compared to the standard catheter (10 vs. 1 cases, P = 0.006. When considering both catheter-associated asymptomatic bacteriuria and CAUTI, the relative risk reduction was 83% (12 vs. 2 cases, P = 0.005. In addition to CAUTI, the risk of acquiring secondary bacteremia was lower (100% for the patients using noble metal alloy catheters (3 cases in the standard group vs. 0 case in the noble metal alloy catheter group, P = 0.24. No adverse events related to any of the used catheters were recorded. Conclusion: Results from this study revealed that noble metal alloy catheters are safe to use and significantly reduce CAUTI rate in ICU patients after 3 days of use.

  8. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  9. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  10. Cost analysis of the Hemodialysis Reliable Outflow (HeRO) Graft compared to the tunneled dialysis catheter.

    Science.gov (United States)

    Al Shakarchi, Julien; Inston, Nicholas; Jones, Robert G; Maclaine, Grant; Hollinworth, David

    2016-04-01

    In end-stage renal disease patients with central venous obstruction, who have limited vascular access options, the Hemodialysis Reliable Outflow (HeRO) Graft is a new alternative with a lower incidence of complications and longer effective device life compared to tunneled dialysis catheters (TDCs). We undertook an economic analysis of introducing the HeRO Graft in the UK. A 1-year cost-consequence decision analytic model was developed comparing management with the HeRO Graft to TDCs from the perspective of the National Health Service in England. The model comprises four 3-month cycles during which the vascular access option either remains functional for hemodialysis or fails, patients can experience access-related infection and device thrombosis, and they can also accrue associated costs. Clinical input data were sourced from published studies and unit cost data from National Health Service 2014-15 Reference Costs. In the base case, a 100-patient cohort managed with the HeRO Graft experienced 6 fewer failed devices, 53 fewer access-related infections, and 67 fewer device thromboses compared to patients managed with TDCs. Although the initial device and placement costs for the HeRO Graft are greater than those for TDCs, savings from the lower incidence of device complications and longer effective device patency reduces these costs. Overall net annual costs are £2600 for each HeRO Graft-managed patient compared to TDC-managed patients. If the National Health Service were to reimburse hemodialysis at a uniform rate regardless of the type of vascular access, net 1-year savings of £1200 per patient are estimated for individuals managed with the HeRO Graft. The base case results showed a marginal net positive cost associated with vascular access with the HeRO Graft compared with TDCs for the incremental clinical benefit of reductions in patency failures, device-related thrombosis, and access-related infection events in a patient population with limited options for

  11. The safety and feasibility of guidezilla catheter in complex coronary interventions and an observational study.

    Science.gov (United States)

    Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo

    2017-10-01

    The monorail Guidezilla guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others.The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications.The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access.In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery.

  12. Do pulmonary artery catheters cause or increase tricuspid or pulmonic valvular regurgitation?

    Science.gov (United States)

    Sherman, S V; Wall, M H; Kennedy, D J; Brooker, R F; Butterworth, J

    2001-05-01

    There are few quantitative data on the extent or mechanism of pulmonary artery catheter (PAC)-induced valvular dysfunction. We hypothesized that PACs cause or worsen tricuspid and pulmonic valvular regurgitation, and tested this hypothesis by using transesophageal echocardiography. In 54 anesthetized adult patients, we measured color Doppler jet areas of tricuspid regurgitation (TR) in two planes (midesophageal [ME] 4-chamber and right ventricular inflow-outflow views) and pulmonic insufficiency (PI) in one plane (ME aortic valve long-axis view), both before and after we advanced a PAC into the pulmonary artery. Regurgitant jet areas and hemodynamic measurements were compared by using paired t-test. There were no significant changes in blood pressure or heart rate after passage of the PAC. After PAC placement, the mean PI jet area was not significantly increased. The mean TR jet area increased significantly in the right ventricular inflow-outflow view (+0.37 +/- 0.11 cm(2)) (P = 0.0014), but did not increase at the ME 4-chamber view. Seventeen percent of patients had an increase in TR jet area > or =1 cm(2); 8% of patients had an increase in PI jet area >/=1 cm(2). In patients without pulmonic or tricuspid valvular pathology, placement of a pulmonary artery catheter (PAC) worsened tricuspid regurgitation, which is consistently visualized in the right ventricular inflow-outflow view, and often not seen in the midesophageal 4-chamber view. This is consistent with malcoaptation of the anterior and posterior leaflets. PAC-induced pulmonic insufficiency was rarely detected in the midesophageal aortic valve long-axis view. We conclude that a PAC is very unlikely to be the sole cause of severe tricuspid regurgitation or pulmonic insufficiency.

  13. Perfusion index and plethysmographic variability index in patients with interscalene nerve catheters.

    Science.gov (United States)

    Sebastiani, Anne; Philippi, Larissa; Boehme, Stefan; Closhen, Dorothea; Schmidtmann, Irene; Scherhag, Anton; Markstaller, Klaus; Engelhard, Kristin; Pestel, Gunther

    2012-12-01

    Interscalene nerve blocks provide adequate analgesia, but there are no objective criteria for early assessment of correct catheter placement. In the present study, pulse oximetry technology was used to evaluate changes in the perfusion index (PI) in both blocked and unblocked arms, and changes in the plethysmographic variability index (PVI) were evaluated once mechanical ventilation was instituted. The PI and PVI values were assessed using a Radical-7™ finger pulse oximetry device (Masimo Corp., Irvine, CA, USA) in both arms of 30 orthopedic patients who received an interscalene catheter at least 25 min before induction of general anesthesia. Data were evaluated at baseline, on application of local anesthetics; five, ten, and 15 min after onset of interscalene nerve blocks; after induction of general anesthesia; before and after a 500 mL colloid fluid challenge; and five minutes thereafter. In the 25 patients with successful blocks, the difference between the PI values in the blocked arm and the PI values in the contralateral arm increased within five minutes of the application of the local anesthetics (P < 0.05) and increased progressively until 15 min. After induction of general anesthesia, the PI increased in the unblocked arm while it remained relatively constant in the blocked arm, thus reducing the difference in the PI. A fluid challenge resulted in a decrease in PVI values in both arms. The perfusion index increases after successful interscalene nerve blockade and may be used as an indicator for successful block placement in awake patients. The PVI values before and after a fluid challenge can be useful to detect changes in preload, and this can be performed in both blocked and unblocked arms.

  14. Application of an ultrasound-guided low-approach insertion technique in three types of totally implantable access port

    Directory of Open Access Journals (Sweden)

    Hung-Wei Cheng

    2014-05-01

    Conclusion: Our study highlights a revised technique for placement of TIAP systems of differing types of material or size. Not only was the curvature of the device catheter smooth, but patients were satisfied with the cosmetic appearance.

  15. Catheters, wires, tubes and drains on postoperative radiographs of pediatric cardiac patients: the whys and wherefores

    Energy Technology Data Exchange (ETDEWEB)

    Teele, Sarah A.; Thiagarajan, Ravi R. [Children' s Hospital Boston, Department of Cardiology, Boston, MA (United States); Harvard Medical School, Department of Pediatrics, Boston, MA (United States); Emani, Sitaram M. [Children' s Hospital Boston, Department of Cardiac Surgery, Boston, MA (United States); Harvard Medical School, Department of Surgery, Boston, MA (United States); Teele, Rita L. [Harvard Medical School, Department of Radiology, Boston, MA (United States); Starship Children' s Hospital, Department of Radiology, Grafton (New Zealand)

    2008-10-15

    Surgical treatment of congenital heart disease has advanced dramatically since the first intracardiac repairs in the mid-20th century. Previously inoperable lesions have become the focus of routine surgery and patients are managed successfully in intensive care units around the world. As a result, increasing numbers of postoperative images are processed by departments of radiology in children's hospitals. It is important that the radiologist accurately documents and describes the catheters, wires, tubes and drains that are present on the chest radiograph. This article reviews the reasons for the placement and positioning of perioperative equipment in children who have surgical repair of atrial septal defect, ventricular septal defect or transposition of the great arteries. Also included are a brief synopsis of each cardiac anomaly, the surgical procedure for its correction, and an in-depth discussion of the postoperative chest radiograph including illustrations of catheters, wires, tubes and drains. (orig.)

  16. Catheters, wires, tubes and drains on postoperative radiographs of pediatric cardiac patients: the whys and wherefores

    International Nuclear Information System (INIS)

    Teele, Sarah A.; Thiagarajan, Ravi R.; Emani, Sitaram M.; Teele, Rita L.

    2008-01-01

    Surgical treatment of congenital heart disease has advanced dramatically since the first intracardiac repairs in the mid-20th century. Previously inoperable lesions have become the focus of routine surgery and patients are managed successfully in intensive care units around the world. As a result, increasing numbers of postoperative images are processed by departments of radiology in children's hospitals. It is important that the radiologist accurately documents and describes the catheters, wires, tubes and drains that are present on the chest radiograph. This article reviews the reasons for the placement and positioning of perioperative equipment in children who have surgical repair of atrial septal defect, ventricular septal defect or transposition of the great arteries. Also included are a brief synopsis of each cardiac anomaly, the surgical procedure for its correction, and an in-depth discussion of the postoperative chest radiograph including illustrations of catheters, wires, tubes and drains. (orig.)

  17. Virtual 5-French intra-aortic pumping using a Glidesheath Slender and 6-French intra-aortic balloon catheter

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: a-takahashi@wine.ocn.ne.jp; Taniguchi, Norimasa; Mizuguchi, Yukio; Yamada, Takeshi; Nakajima, Shunsuke; Hashimoto, Sho; Hata, Tetsuya

    2015-07-15

    Objectives: The aim of this study was to evaluate the feasibility and safety of the 6-Fr Glidesheath Slender, which has equivalent outer size to the conventional 5-Fr sheath, for use with the 6-Fr intra-aortic balloon pump (IABP) catheter. Methods: Between May 2014 and March 2015, 24 patients with acute coronary syndrome underwent percutaneous coronary intervention using a 6-Fr IABP catheter through a 6-Fr Glidesheath Slender for support. The adverse events, including access site complications, kinking of the sheath during the procedure, and any evidence of balloon pump failure, were retrospectively investigated. Results: Insertion of the IABP catheter through either the femoral or brachial artery was successful in all patients. The mean support time was 32.4 ± 22.0 h. No major hemorrhagic event or severe limb ischemia was observed. Kinking of the shaft occurred during insertion in one patient; however, the subsequent balloon pumping was well maintained and did not require exchange of the sheath or IABP catheter. No kind of IABP failure was observed. Conclusion: Although this sheath was originally designed to allow radial access, our results suggest that the use of the Glidesheath Slender is feasible for insertion of the 6-Fr IABP catheter through the brachial and femoral arteries, and may reduce vascular complications in patients who undergo percutaneous coronary intervention.

  18. Tunnelled haemodialysis catheter and haemodialysis outcomes: a retrospective cohort study in Zagreb, Croatia.

    Science.gov (United States)

    Pašara, Vedran; Maksimović, Bojana; Gunjača, Mihaela; Mihovilović, Karlo; Lončar, Andrea; Kudumija, Boris; Žabić, Igor; Knotek, Mladen

    2016-05-17

    Studies have reported that the tunnelled dialysis catheter (TDC) is associated with inferior haemodialysis (HD) patient survival, in comparison with arteriovenous fistula (AVF). Since many cofactors may also affect survival of HD patients, it is unclear whether the greater risk for survival arises from TDC per se, or from associated conditions. Therefore, the aim of this study was to determine, in a multivariate analysis, the long-term outcome of HD patients, with respect to vascular access (VA). Retrospective cohort study. This retrospective cohort study included all 156 patients with a TDC admitted at University Hospital Merkur, from 2010 to 2012. The control group consisted of 97 patients dialysed via AVF. The groups were matched according to dialysis unit and time of VA placement. The site of choice for the placement of the TDC was the right jugular vein. Kaplan-Meier analysis with log-rank test was used to assess patient survival. Multivariate Cox regression analysis was used to determine independent variables associated with patient survival. Patient survival with respect to VA. The cumulative 1-year survival of patients who were dialysed exclusively via TDC was 86.4% and of those who were dialysed exclusively via AVF, survival was 97.1% (p=0.002). In multivariate Cox regression analysis, male sex and older age were independently negatively associated with the survival of HD patients, while shorter HD vintage before the creation of the observed VA, hypertensive renal disease and glomerulonephritis were positively associated with survival. TDC was an independent risk factor for survival of HD patients (HR 23.0, 95% CI 6.2 to 85.3). TDC may be an independent negative risk factor for HD patient survival. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Prevention and control of catheter-associated urinary tract infections - implementation of the recommendations of the Commission for Hospital Hygiene and Infection Prevention (KRINKO) in nursing homes for the elderly in Frankfurt am Main, Germany.

    Science.gov (United States)

    Heudorf, Ursel; Gasteyer, Stefanie; Müller, Maria; Samoiski, Yvonne; Serra, Nicole; Westphal, Tim

    2016-01-01

    Urinary tract infections range among the most frequent infections not only in hospital patients but also in residents of long-term care facilities for the elderly. Urinary catheters are the greatest risk factor for urinary tract infections. In the guidance paper on the "prevention of infections in nursing homes" (2005) as well as in the updated recommendations for the "prevention and control of catheter-associated urinary tract infections" (2015), the Commission for Hospital Hygiene and Infection Prevention (KRINKO) has recommended adequate preventive measures. In 2015, the implementation of these KRINKO recommendations was investigated. All of Frankfurt's 40 nursing homes were evaluated using a checklist based on the KRINKO recommendations. The evaluation included assessing the availability of operating instructions, appropriate indications for the placement of catheters etc. Age, sex and duration of catheterization, as well as current and previous infections within the past 6 months were documented for every resident with a catheter. In 35 (87.5%) of the nursing homes, operating instructions for the handling of urinary tract catheters were available. The decision as to whether a catheter is indicated is made by physicians, while its placement is often delegated to the nursing service. Typically, silicon catheters are used. In three-quarters of the nursing homes, regular intervals of 4-6 weeks for changing catheters were reported. On the respective survey day, 7.3% of the residents were catheterized. On the survey day, 3.6% (4.2%) and in the previous 6 months a total of 28% (28.9%) of the residents had a urinary tract infection (prevalence of antibiotic therapy in parentheses). Ciprofloxacin was used most often followed by cefuroxime and cotrimoxazole. In the current evaluation, fewer nursing home residents were catheterized than in previous years and the rate of urinary tract infections was low. This indicates an increasingly cautious and apparently appropriate

  20. When one port does not return blood: two case reports of rare causes for misplaced central venous catheters

    Directory of Open Access Journals (Sweden)

    Sandra Pereira

    2016-01-01

    Full Text Available We present two cases of misplaced central venous catheters having in common the absence of free blood return from one lumen immediately after placement. The former is a case of right hydrothorax associated with central venous catheterization with the catheter tip in intra-pleural location. In this case the distal port was never patent. In the latter case there was an increased aspiration pressure through the middle port due to a catheter looping.The absence of free flow on aspiration from one lumen of a central catheter should not be undervalued. In these circumstances the catheter should not be used and needs to be removed. Resumo: Apresentamos dois casos de mau posicionamento de cateter venoso central. Têm em comum a ausência do retorno sanguíneo livre em um dos lúmens imediatamente após a colocação. O primeiro é um caso de hidrotórax direito associado ao cateterismo venoso central, com a ponta do cateter em localização intrapleural. Nesse caso, a porta distal nunca esteve patente. No segundo caso houve um aumento da pressão de aspiração através da porta medial por causa da formação de alça no cateter.A ausência de fluxo livre na aspiração de um lúmen do cateter central não deve ser subestimada. Nessas circunstâncias, o cateter não deve ser usado e deve ser removido. Keywords: Central venous catheter, Hydrothorax, Looping, Malposition, Palavras-chave: Cateter venoso central, Hidrotórax, Alça, Mau posicionamento

  1. Acesso vascular para hemodiálise com cateter temporário de duplo lúmen em cães com insuficiência renal aguda Hemodialysis vascular access with temporary double-lumen catheter in dogs with acute renal failure

    Directory of Open Access Journals (Sweden)

    Alessandra Melchert

    2008-08-01

    Full Text Available A hemodiálise é uma modalidade terapêutica que pode sustentar a vida do paciente com insuficiência renal aguda (IRA, enquanto este recupera a função renal. Para sua realização, é necessário estabelecer circulação extracorpórea, para que seja realizada a filtração do sangue, impondo a necessidade de um acesso vascular viável e eficiente. O objetivo deste estudo foi avaliar a eficiência e as complicações do acesso vascular para hemodiálise (HD, com cateter temporário de duplo lúmen inserido na veia jugular externa. Foram estudados 10 cães com IRA induzida por gentamicina, submetidos a sessões diárias de HD, com duração de uma hora, até a recuperação da função renal ou óbito. Foram realizadas 104 sessões de HD nos animais estudados, observando-se necessidade de troca do cateter em sete sessões (6,7%, devido à obstrução do lúmen do cateter em seis sessões (5,8% ou por saída acidental do mesmo em uma sessão (1,0%. Não se observou migração do cateter, infecção, hemorragia ou hematoma no local de entrada do cateter na pele, obtendo-se fluxo sanguíneo patente em 90,4% das sessões. Concluiu-se que o acesso vascular na veia jugular externa com cateter temporário de duplo-lúmen mostrou-se viável, com ocorrência de poucas complicações, sendo, portanto, indicado como forma de acesso para a circulação extracorpórea para HD em cães com IRA.Hemodialysis is a therapeutic procedure that can sustain the patient's life in acute renal failure (ARF, during the renal function recover. To perform hemodialysis (HD, an extracorporeal circulation is established to blood filtration, imposing the need of a viable and efficient vascular access. The aim of this study was to evaluate the effectiveness and complications of the HD vascular access with temporary double-lumen catheter inserted into the external jugular vein. Ten mongrel dogs with ARF, induced by gentamicin administration, were submitted to daily

  2. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    Science.gov (United States)

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  3. [A clinical observation of percutaneous balloon dilation and maintenance percutaneous transhepatic cholangial catheter drainage for treatment of 21 patients with benign biliary strictures and difficult endoscopy].

    Science.gov (United States)

    Pan, Jie; Shi, Hai-feng; Li, Xiao-guang; Zhang, Xiao-bo; Liu, Wei; Jin, Zheng-yu; Hong, Tao; Yang, Ai-ming; Yang, Ning

    2012-06-01

    To investigate the value of percutaneous balloon dilation and percutaneous transhepatic cholangial drainage (PTCD) catheter maintenance in the treatment of benign biliary strictures. The clinical data of 21 patients with benign biliary strictures at Peking Union Medical College Hospital from June 2005 to June 2011 were retrospectively studied, in which 12 patients in severe stricture (stenosis > 70%) were treated with percutaneous balloon dilation and PTCD catheter placed across the stricture, while another 9 patients in median stricture (stenosis stenosis was seen in 2 patients. A severe complication with biliary artery branch rupture and massive hemobilia was seen in 1 patient during balloon dilation. Of the 9 patients only treated with 1 - 12 months (median: 6 months) of PTCD catheter placement, 7 patients had the catheter successfully removed. In the follow-up of 5 - 18 months (median: 8 months), patency of bile duct was preserved in 5 of 7 patients, and recurrent stenosis was seen in 2 patients. No severe complication occurred. When endoscopy therapy is failed or the patient can't undergo endoscopy therapy, the percutaneous balloon dilation and PTCD catheter maintenance method is an effective alternative therapeutic approach in the treatment of benign biliary strictures. The moderate benign biliary stricture may be effectively treated only by the PTCD catheter maintenance method.

  4. Understanding the information and resource needs of UK health and social care placement students.

    Science.gov (United States)

    Callaghan, Lynne; Doherty, Alan; Lea, Susan J; Webster, Daniel

    2008-12-01

    Students on health and social care degree programmes spend 50% of their time on practice placements. Because of the diversity of settings and the need to evidence their work, it is vital to understand the information and resource needs of placement students. The aim of this investigation was to understand the needs of placement students in terms of accessing resources whilst they are in the field in order to inform a guide to meet these needs. Focus groups were conducted with students on midwifery, social work and post-registration health professions degree programmes on three different sites across the region. Data were analysed using Thematic Content Analysis. Three themes emerged from the data: inequality, user education needs and students' solutions and strategies. It is essential to speak to placement students in order to understand their needs in terms of accessing and using library resources. The timing and content of information skills training is key to meeting student needs while on placement.

  5. Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients

    International Nuclear Information System (INIS)

    Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.; Siegel, Randall L.; Biswal, Rajiv; Gribbin, Christopher E.; Tokarz, Robert

    2000-01-01

    Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. A combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant

  6. Anticoagulants for the prevention and treatment of catheter-related thrombosis in adults and children on parenteral nutrition: a systematic review and critical appraisal

    NARCIS (Netherlands)

    Barco, Stefano; Atema, Jasper J.; Coppens, Michiel; Serlie, Mireille J.; Middeldorp, Saskia

    2017-01-01

    Patients on parenteral nutrition require a central venous access and are at risk of catheter-related thrombosis, pulmonary embolism, and vena cava syndrome. Parenteral nutrition guidelines suggest anticoagulation for the primary prevention of catheter-related thrombosis during long-term parenteral

  7. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    Science.gov (United States)

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  8. Pelvic drainage during removal of dialysis catheter decreases the risk of subsequent intra-abdominal complications in refractory peritoneal dialysis-related peritonitis.

    Science.gov (United States)

    Hsu, Chih-Yang; Huang, Wei-Chieh; Huang, Chun-Kai; Huang, Chien-Wei; Chou, Nan-Hua; Lee, Po-Tsang; Fang, Hua-Chang; Chou, Kang-Ju; Chen, Chien-Liang

    2015-11-01

    Some patients with refractory peritoneal dialysis-related peritonitis continue to develop intra-abdominal complications despite removal of the peritoneal catheter. Repeated percutaneous drainage or open laparotomy is often required, and mortality is not uncommon. The benefits of pelvic drainage placement during catheter removal in decreasing these complications and interventions remain unproven. Forty-six patients with refractory peritonitis who underwent removal of a Tenckhoff catheter between 1991 and 2013 were reviewed retrospectively. Twelve patients had pelvic drainage using closed active suction devices during catheter removal (drainage group). The remaining 34 patients underwent catheter removal without drainage (non-drainage group). The outcomes measured were the development of intra-abdominal complications and the requirement for repeated percutaneous drainage or open laparotomy within 90 days after the catheter removal. Baseline characteristics were similar with the exception of a higher median number of previous peritonitis episodes in the drainage group compared with the non-drainage group (2 vs 0, P = 0.02). During the follow-up period, intra-abdominal complications occurred in 15 (44%) of 34 patients in the non-drainage group, compared with one (8%) of 12 patients in the drainage group (P = 0.03). Twelve (35%) patients in the non-drainage group required repeated percutaneous drainage or open laparotomy for management, compared with zero (0%) patients in the drainage group (P = 0.02). Drain tubes were removed at a median of 6 days (inter-quartile range: 5-10) without complications. In the management of refractory peritonitis, pelvic drainage during removal of dialysis catheter decreases the risk of subsequent intra-abdominal complications and invasive interventions. © 2015 Asian Pacific Society of Nephrology.

  9. Epidural Catheter Breakage In-Situ

    Directory of Open Access Journals (Sweden)

    Geetanjali S Verma

    2014-09-01

    Full Text Available A 45yr old woman diagnosed with dysfunctional uterine bleeding and incisional hernia was planned for total abdominal hysterectomy with bilateral salpingo-oophorectomy and mesh repair under combined spinal and epidural anaesthesia. Using VYGON® epidural catheter with its recommended introducer, the catheter was inserted but it snapped off at 11cm mark while positioning the catheter. After radiological confirmation, the neurosurgeon removed the catheter under general anaesthesia, which was followed by the scheduled surgery.

  10. Embracing Errors in Simulation-Based Training: The Effect of Error Training on Retention and Transfer of Central Venous Catheter Skills.

    Science.gov (United States)

    Gardner, Aimee K; Abdelfattah, Kareem; Wiersch, John; Ahmed, Rami A; Willis, Ross E

    2015-01-01

    Error management training is an approach that encourages exposure to errors during initial skill acquisition so that learners can be equipped with important error identification, management, and metacognitive skills. The purpose of this study was to determine how an error-focused training program affected performance, retention, and transfer of central venous catheter (CVC) placement skills when compared with traditional training methodologies. Surgical interns (N = 30) participated in a 1-hour session featuring an instructional video and practice performing internal jugular (IJ) and subclavian (SC) CVC placement with guided instruction. All interns underwent baseline knowledge and skill assessment for IJ and SC (pretest) CVC placement; watched a "correct-only" (CO) or "correct + error" (CE) instructional video; practiced for 30 minutes; and were posttested on knowledge and IJ and SC CVC placement. Skill retention and transfer (femoral CVC placement) were assessed 30 days later. All skills tests (pretest, posttest, and transfer) were videorecorded and deidentified for evaluation by a single blinded instructor using a validated 17-item checklist. Both the groups exhibited significant improvements (p error-based activities and discussions into training programs can be beneficial for skill retention and transfer. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  11. Safety of peritoneal and pleural drain placement in pediatric stem cell transplant recipients with severe veno-occlusive disease.

    Science.gov (United States)

    Madenci, Arin L; Stetson, Alyssa; Weldon, Christopher B; Lehmann, Leslie E

    2016-08-01

    Hepatic VOD (veno-occlusive disease) is a serious complication of HSCT (hematopoietic stem cell transplantation) and has historically been associated with high mortality. This obstruction to hepatic flow often results in fluid collections in the peritoneal and pleural cavities. Catheter placement to drain ascites or pleural fluid may reduce intra-abdominal hypertension and/or improve respiratory parameters. The safety of these interventions among critically ill, immunocompromised children is unknown. Among 32 HSCT recipients (2000-2012) with severe VOD, we assessed the primary outcome of procedural complication from peritoneal drain placement. Twenty-four (75%) patients underwent peritoneal drain placement. No patient sustained visceral perforation or hemorrhage with drain placement. Overall mortality was 47% (n = 15). The procedure was not associated with increased overall mortality (p > 0.99). Eight (25%) peritoneal drains required replacement for malfunction. Of 24 patients with peritoneal drains, one (4%) patient had a positive culture from ascitic fluid. Eight (25%) patients underwent pleural drain placement. No pleural drain-related procedural complication or infection occurred. Four (50%) of the eight patients with pleural drains had de-escalation in oxygen requirement at drain removal, compared to time of placement. In this study, peritoneal and pleural drains were safe interventions for children with severe VOD. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

    International Nuclear Information System (INIS)

    Breault, Stéphane; Glauser, Frédéric; Babaker, Malik; Doenz, Francesco; Qanadli, Salah Dine

    2015-01-01

    PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement

  13. Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Breault, Stéphane, E-mail: stephane.breault@chuv.ch [Lausanne University Hospital, Diagnostic and Interventional Radiology Department (Switzerland); Glauser, Frédéric, E-mail: frederic.glauser@chuv.ch [Lausanne University Hospital, Angiology and Diagnostic and Interventional Radiology Departments (Switzerland); Babaker, Malik, E-mail: malik.babaker@chuv.ch; Doenz, Francesco, E-mail: francesco.doenz@chuv.ch; Qanadli, Salah Dine, E-mail: salah.qanadli@chuv.ch [Lausanne University Hospital, Diagnostic and Interventional Radiology Department (Switzerland)

    2015-06-15

    PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

  14. Radiation dose associated with CT-guided drain placement for pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G. [University of North Carolina at Chapel Hill, Department of Radiology, UNC Health Care, Chapel Hill, NC (United States); Taylor, J.B. [University of North Carolina at Chapel Hill, Environment, Health and Safety, Chapel Hill, NC (United States)

    2017-05-15

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  15. Radiation dose associated with CT-guided drain placement for pediatric patients

    International Nuclear Information System (INIS)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G.; Taylor, J.B.

    2017-01-01

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  16. Word catheter and marsupialisation in women with a cyst or abscess of the Bartholin gland (WoMan-trial): a randomised clinical trial.

    Science.gov (United States)

    Kroese, J A; van der Velde, M; Morssink, L P; Zafarmand, M H; Geomini, P; van Kesteren, Pjm; Radder, C M; van der Voet, L F; Roovers, Jpwr; Graziosi, Gcm; van Baal, W M; van Bavel, J; Catshoek, R; Klinkert, E R; Huirne, Jaf; Clark, T J; Mol, Bwj; Reesink-Peters, N

    2017-01-01

    To compare recurrence of a cyst or abscess of the Bartholin gland after surgical treatment using a Word catheter or marsupialisation. Multicentre, open-label, randomised controlled trial. Eighteen hospitals in the Netherlands and one hospital in England. Women with a symptomatic cyst or abscess of the Bartholin gland. Women were randomised to treatment with Word catheter or marsupialisation. The primary outcome was recurrence of the cyst or abscess within 1 year of treatment. The secondary outcomes included pain during and after treatment (measured on a 10-point scale), use of analgesics, and time from diagnosis to treatment. Analysis was by intention-to-treat. To assess whether marsupialisation would reduce the recurrence rate by 5% (from 20 to 15%) we needed to include 160 women (alpha error 0.05, beta error 0.2). One hundred and sixty-one women were randomly allocated to treatment by Word catheter (n = 82) or marsupialisation (n = 79) between August 2010 and May 2014. Baseline characteristics were comparable. Recurrence occurred in 10 women (12%) allocated to Word catheter versus eight women (10%) allocated to marsupialisation: relative risk (RR) 1.1, 95% confidence interval (CI) 0.64-1.91; P = 0.70. Pain scores after treatment were also comparable. In the first 24 hours after treatment, 33% used analgesics in the Word catheter group versus 74% in the marsupialisation group (P < 0.001). Time from diagnosis to treatment was 1 hour for placement of Word catheter versus 4 hours for marsupialisation (P = 0.001). In women with an abscess or cyst of the Bartholin gland, treatment with Word catheter and marsupialisation results in comparable recurrence rates. Comparable recurrence rates for treatment of Bartholinic abscess/cyst with Word catheter and marsupialisation. © 2016 Royal College of Obstetricians and Gynaecologists.

  17. Hepatic venous outflow obstruction after living donor liver transplantation managed with ectopic placement of a foley catheter: A case report

    Directory of Open Access Journals (Sweden)

    Mohamed Abdel Wahab

    2015-01-01

    Conclusion: We report the use of foley catheter to temporary fix the graft and correct the HVOO. It is a simple and safe way, and could be easily monitored and removed under Doppler US without any complications.

  18. Multiple versus single lumen umbilical venous catheters for newborn infants.

    Science.gov (United States)

    Kabra, N S; Kumar, M; Shah, S S

    2005-07-20

    Multiple lumen umbilical venous catheters (ML-UVCs) instead of single lumen UVCs (SL-UVCs) may decrease the need for additional venous lines. Although it seems self-evident that ML-UVCs would reduce the need of additional venous lines, the rates of associated complications might be different. To compare the effectiveness and the safety of ML-UVCs versus SL-UVCs in terms of need of additional vascular access, rates of complications, morbidity and mortality in newborn infants. Randomized and quasi-randomized trials were identified by searching the MEDLINE (1966 - February 2005), EMBASE (1980- February 2005), CINAHL (1982 - February 2005), the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 4, 2004) and Science Direct (subject area: medicine, journal and abstract database; 1967 to February 2005). Literature search also included a manual search of the abstracts of scientific meetings published in Pediatric Research (1990-2004). Additional citations were sought using references in articles retrieved from searches. Subject experts were contacted to identify the unpublished and ongoing studies. Randomized and quasi-randomized controlled clinical trials comparing safety and efficacy of multiple versus single lumen umbilical venous catheter in neonates (both term and preterm) who were in need of umbilical venous catheter insertion for vascular access in first four weeks of life. Each review author performed data extraction independently and differences were resolved by discussion. The following outcomes were determined: total number of additional peripheral intravenous lines per baby in first week and first four weeks of life, total number of additional percutaneously and surgically placed central venous lines per baby in first four weeks of life, and other safety and efficacy measures. The treatment effect estimators used were RR, RD, and WMD when appropriate along with their 95% CI. If RD was statistically significant, then number

  19. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Relative incidence of phlebitis associated with peripheral intravenous catheters in the lower versus upper extremities.

    Science.gov (United States)

    Benaya, A; Schwartz, Y; Kory, R; Yinnon, A M; Ben-Chetrit, E

    2015-05-01

    Peripheral venous access in elderly, hospitalized patients is often challenging. The usual alternative is insertion of a central venous catheter, with associated risk for complications. The purpose of this investigation was to determine the relative incidence of phlebitis secondary to lower as compared to upper extremity intravenous catheters (IVCs) and associated risk factors. A non-randomized, observational, cohort-controlled study was carried out. Consecutive patients receiving a lower extremity IVC were enrolled and compared with patients receiving an upper extremity IVC. Patients were followed from insertion until removal of the IVC. The major endpoint was phlebitis. The incidence of phlebitis secondary to upper extremity IVCs was 3/50 (6 %) compared to 5/53 (9.4 %) in lower extremity IVCs (χ(2) Yates = 0.08, p = 0.776). Age, gender, obesity, diabetes mellitus, site (arm versus leg, left versus right), and size of needle were not found to be risk factors for phlebitis according to univariate analysis. None of the patients developed bloodstream infection. In elderly patients with poor venous access, lower extremity IVCs are a reasonable and low-risk alternative to central venous catheters.

  1. Features and selection of vascular access devices.

    Science.gov (United States)

    Sansivero, Gail Egan

    2010-05-01

    To review venous anatomy and physiology, discuss assessment parameters before vascular access device (VAD) placement, and review VAD options. Journal articles, personal experience. A number of VAD options are available in clinical practice. Access planning should include comprehensive assessment, with attention to patient participation in the planning and selection process. Careful consideration should be given to long-term access needs and preservation of access sites. Oncology nurses are uniquely suited to perform a key role in VAD planning and placement. With knowledge of infusion therapy, anatomy and physiology, device options, and community resources, nurses can be key leaders in preserving vascular access and improving the safety and comfort of infusion therapy. Copyright 2010 Elsevier Inc. All rights reserved.

  2. Percutaneous transcholecystic approach for an experiment of biliary stent placement: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Medical School of Gachon, Inchon (Korea, Republic of); Song, Ho Young; Lim, Jin Oh; Ko, Gi Young; Sung, Kyu Bo; Kim, Tae Hyung; Lee, Ho Jung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-06-01

    To determine, in an experimental study of biliary stent placement, the usefulness and safety of the percutaneous transcholecystic approach and the patency of a newly designed biliary stent. A stent made of 0.15-mm-thick nitinol wire, and 10 mm in diameter and 2 cm in length, was loaded in an introducer with an 8-F outer diameter. The gallbladders of seven mongrel dogs were punctured with a 16-G angiocath needle under sonographic guidance, and cholangiography was performed. After anchoring the anterior wall of the gallbladder to the abdominal wall using a T-fastener, the gallbladder body was punctured again under fluoroscopic guidance. The cystic and common bile ducts were selected using a 0.035-inch guide wire and a cobra catheter, and the stent was placed in the common bile duct. Post-stenting cholangiography was undertaken, and an 8.5-F drainage tube was inserted in the gallbladder. Two dogs were followed-up and sacrificed at 2,4 and 8 weeks after stent placement, respectively, and the other expired 2 days after stent placement. Follow-up cholangiograms were obtained before aninmal was sacrified, and a pathologic examination was performed. Stent placement was technically successful in all cases. One dog expired 2 days after placement because of bile peritonitis due to migration of the drainage tube into the peritoneal cavity, but the other six remained healthy during the follow-up period. Cholangiography performed before the sacrifice of each dog showed that the stents were patent. Pathologic examination revealed the proliferation of granulation tissue at 2 weeks, and complete endothelialization over the stents by granulation tissue at 8 weeks. Percutaneous transcholecystic biliary stent placement appears to be safe, easy and useful. After placement, the stent was patent during the follow-period.

  3. Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Goossens, G. A.; Vaninbroukx, Johan; Jerôme, M.; Stas, M.

    2012-01-01

    Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 ± 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD’s tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

  4. Prevention and control of catheter-associated urinary tract infections – implementation of the recommendations of the Commission for Hospital Hygiene and Infection Prevention (KRINKO in nursing homes for the elderly in Frankfurt am Main, Germany

    Directory of Open Access Journals (Sweden)

    Heudorf, Ursel

    2016-06-01

    Full Text Available Introduction: Urinary tract infections range among the most frequent infections not only in hospital patients but also in residents of long-term care facilities for the elderly. Urinary catheters are the greatest risk factor for urinary tract infections. In the guidance paper on the “prevention of infections in nursing homes” (2005 as well as in the updated recommendations for the “prevention and control of catheter-associated urinary tract infections” (2015, the Commission for Hospital Hygiene and Infection Prevention (KRINKO has recommended adequate preventive measures. In 2015, the implementation of these KRINKO recommendations was investigated.Method: All of Frankfurt’s 40 nursing homes were evaluated using a checklist based on the KRINKO recommendations. The evaluation included assessing the availability of operating instructions, appropriate indications for the placement of catheters etc. Age, sex and duration of catheterization, as well as current and previous infections within the past 6 months were documented for every resident with a catheter.Results: In 35 (87.5% of the nursing homes, operating instructions for the handling of urinary tract catheters were available. The decision as to whether a catheter is indicated is made by physicians, while its placement is often delegated to the nursing service. Typically, silicon catheters are used. In three-quarters of the nursing homes, regular intervals of 4–6 weeks for changing catheters were reported. On the respective survey day, 7.3% of the residents were catheterized. On the survey day, 3.6% (4.2% and in the previous 6 months a total of 28% (28.9% of the residents had a urinary tract infection (prevalence of antibiotic therapy in parentheses. Ciprofloxacin was used most often followed by cefuroxime and cotrimoxazole.Discussion: In the current evaluation, fewer nursing home residents were catheterized than in previous years and the rate of urinary tract infections was low

  5. Factors influencing radiation therapy student clinical placement satisfaction

    Science.gov (United States)

    Bridge, Pete; Carmichael, Mary-Ann

    2014-01-01

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning. PMID:26229635

  6. Factors influencing radiation therapy student clinical placement satisfaction

    Energy Technology Data Exchange (ETDEWEB)

    Bridge, Pete; Carmichael, Mary-Ann [School of Clinical Sciences, Queensland University of Technology, Brisbane (Australia)

    2014-02-15

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning.

  7. Factors influencing radiation therapy student clinical placement satisfaction

    International Nuclear Information System (INIS)

    Bridge, Pete; Carmichael, Mary-Ann

    2014-01-01

    Introduction: Radiation therapy students at Queensland University of Technology (QUT) attend clinical placements at five different clinical departments with varying resources and support strategies. This study aimed to determine the relative availability and perceived importance of different factors affecting student support while on clinical placement. The purpose of the research was to inform development of future support mechanisms to enhance radiation therapy students’ experience on clinical placement. Methods: This study used anonymous Likert-style surveys to gather data from years 1 and 2 radiation therapy students from QUT and clinical educators from Queensland relating to availability and importance of support mechanisms during clinical placements in a semester. Results: The study findings demonstrated student satisfaction with clinical support and suggested that level of support on placement influenced student employment choices. Staff support was perceived as more important than physical resources; particularly access to a named mentor, a clinical educator and weekly formative feedback. Both students and educators highlighted the impact of time pressures. Conclusions: The support offered to radiation therapy students by clinical staff is more highly valued than physical resources or models of placement support. Protected time and acknowledgement of the importance of clinical education roles are both invaluable. Joint investment in mentor support by both universities and clinical departments is crucial for facilitation of effective clinical learning

  8. Effect of chlorhexidine/silver sulfadiazine-impregnated central venous catheters in an intensive care unit with a low blood stream infection rate after implementation of an educational program: a before-after trial.

    Science.gov (United States)

    Schuerer, Douglas J E; Zack, Jeanne E; Thomas, James; Borecki, Ingrid B; Sona, Carrie S; Schallom, Marilyn E; Venker, Melissa; Nemeth, Jennifer L; Ward, Myrna R; Verjan, Linda; Warren, David K; Fraser, Victoria J; Mazuski, John E; Boyle, Walter A; Buchman, Timothy G; Coopersmith, Craig M

    2007-08-01

    Current guidelines recommend using antiseptic- or antibiotic-impregnated central venous catheters (CVCs) if, following a comprehensive strategy to prevent catheter-related blood stream infection (CR-BSI), infection rates remain above institutional goals based on benchmark values. The purpose of this study was to determine if chlorhexidine/silver sulfadiazine-impregnated CVCs could decrease the CR-BSI rate in an intensive care unit (ICU) with a low baseline infection rate. Pre-intervention and post-intervention observational study in a 24-bed surgical/trauma/burn ICU from October, 2002 to August, 2005. All patients requiring CVC placement after March, 2004 had a chlorhexidine/silver sulfadiazine-impregnated catheter inserted (post-intervention period). Twenty-three CR-BSIs occurred in 6,960 catheter days (3.3 per 1,000 catheter days)during the 17-month control period. After introduction of chlorhexidine/silver sulfadiazine-impregnated catheters, 16 CR-BSIs occurred in 7,732 catheter days (2.1 per 1,000 catheter days; p = 0.16). The average length of time required for an infection to become established after catheterization was similar in the two groups (8.4 vs. 8.6 days; p = 0.85). Chlorhexidine/silver sulfadiazine-impregnated catheters did not result in a statistically significant change in the microbiological profile of CR-BSIs, nor did they increase the incidence of resistant organisms. Although chlorhexidine/silver sulfadiazine-impregnated catheters are useful in specific patient populations, they did not result in a statistically significant decrease in the CR-BSI rate in this study, beyond what was achieved with education alone.

  9. Image-Guided Transvesicular Drainage of Pelvic Fluid Collections: A Safe and Effective Alternative Approach.

    Science.gov (United States)

    Ayyagari, Raj R; Yeh, Cliff; Arici, Melih; Mojibian, Hamid; Reiner, Eric; Pollak, Jeffrey S

    2016-05-01

    To evaluate the safety and efficacy of percutaneous transvesicular drainage of pathologic pelvic fluid collections, a series of 15 patients who underwent 16 transvesicular drainage catheter placements was retrospectively reviewed. All patients had collections suspicious for infection that were posterior to the bladder or superior to the bladder behind loops of bowel, and were otherwise inaccessible. All 15 collections were percutaneously accessed via the bladder with standard drainage catheters. All collections resolved completely with no complications. Percutaneous transvesicular drainage was a safe and effective technique in this series, and can be considered when no direct percutaneous access routes are available. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  10. SURVIVAL OF CONTINUOUS AMBULATORY PERITONEAL DIALYSIS CATHETERS: AN EVALUATION OF SURGICAL AND NON-SURGICAL FACTORS (SINGLE CENTER STUDY

    Directory of Open Access Journals (Sweden)

    A. Keshvari

    2006-06-01

    Full Text Available Peritoneal dialysis is an established form of renal replacement therapy used in many patients with end-stage renal disease. The key to a successful chronic peritoneal dialysis is a permanent and safe access to the peritoneal cavity. This study was conducted in order to evaluate the catheter survival and its related factors in Imam Khomeini Hospital. A total of 80 catheters were inserted into 69 patients (52 men and 28 women with end-stage chronic renal failure during a period of 84 months. Retrospectively the correlation between catheter survival (overall and event free with demographic factors (sex and age, surgical factors (surgeons and surgical methods, nephrologic factors (the causes of peritoneal dialysis selection and the history of hemodialysis and peritonitis factors (the history and number of peritonitis has been evaluated. The mean age of the patients was 48.35 years (16 to 79 years. The overall survival of catheters or the probability of having a functioning catheter after one, two and three years was 53%, 41%, 22%, respectively. The event free survival of the catheter or the probability of having a functioning catheter without any problems after one year was 14%. It has been found out that among all factors in this study only history of hemodialysis had statistically significant effect on the overall survival of continuous ambulatory peritoneal dialysis catheter (P = 0.04. It seems that the overall survival of catheters is better when CAPD is started before any other attempts for hemodialysis.

  11. Placement and retrieval of a Guenther tulip filter in patients with a free floating thrombus in inferior vena cava

    International Nuclear Information System (INIS)

    Seong, Min Hyun; Kim, Young Hwan; Lee, Sang Kwon; Choi, Jin Soo; Kim, Mi Jeong; Koo, Ja Hyun; Kim, Hyoung Tae; Cho, Won Hyun; Seong, Nak Kwan

    2005-01-01

    We wanted to assess the technical feasibility and clinical efficacy of the placement and retrieval of a Guenther Tulip filter for the prevention of fatal pulmonary embolism during the management of patients with a free floating thrombus in their inferior vena ca va (IVC). Six patients having a free floating thrombus in their IVC (three patients with an isolated free floating thrombus in the IVC that resulted from immobilization due to traumatic liver injury or cerebral infarction, two patients with coexisting deep vein thrombosis in the left lower extremity that was caused by May-Thurner syndrome, and one patient with coexisting deep vein thrombosis in the right lower extremity that was due to nephrotic syndrome and immobilization after hip joint replacement) underwent placement and retrieval of a Guenther Tulip filter. The placement of the filter was performed through the right internal jugular vein to prevent the risk of detachment of the thrombus during the procedure. Retrieval of filter was performed after the free floating thrombus of the IVC had disappeared on follow-up CT because of anticoagulation therapy, aspiration thrombectomy or catheter directed Urokinase thrombolysis. The Guenther Tulip filter was successfully placed in the IVC in all six patients and it was retrieved after the management of the free floating thrombus. The mean duration of the placement of the filter was 11 days (range:7-25 days). Two patients underwent placement of an iliac vein stent for the management of May-Thurner syndrome. Detachment of the free floating thrombus in the IVC and the subsequent thrombus entrapment in the filter were documented during aspiration thrombectomy or Urokinase thrombolysis in four patients. Recurrent thrombus didn't occur during the follow-up period (range:3-20 months) in five of the six patients. In one patient, a recurrent thrombus due to the discontinuance of anticoagulation therapy was identified at the filter detachment site of the IVC on the follow

  12. Ultrasound-guided approach to the paravertebral space for catheter insertion in infants and children.

    Science.gov (United States)

    Boretsky, Karen; Visoiu, Mihaela; Bigeleisen, Paul

    2013-12-01

    Paravertebral perineural blocks are used to prevent pain in the thoracoabdominal dermatomes. Traditionally, a landmark-based technique is used in children, while ultrasound-guided (UG) techniques are being employed in adult patients. To describe an UG technique for placement of thoracic paravertebral nerve block (TPVNB) catheters in pediatric patients. Retrospective chart review of a series of 22 pediatric patients' ages 6 months to 17 years with weights from 6.25 kg to 135 kg using a transverse in-plane technique. Catheters were placed both bilateral and unilateral for a variety of thoracic and abdominal procedures. A linear ultrasound transducer was used in all cases with frequency of oscillation and transducer length chosen based on individual patient characteristics of age, weight, and BMI. The median pain scores at 12, 24, 36, and 48 h were 1.2 (interquartile range, 4.5), 0.84 (interquartile range 3.0), 1.6 (interquartile range 2.9), and 0.83 (interquartile range 1.74), respectively. The median dose of opioid expressed as morphine equivalents consumed during the first 24 h after surgery was 0.14 mg·kg(-1) (interquartile range, 0.78 mg·kg(-1) ) and from 24 to 48 h the median dose was 0.11 mg·kg(-1) (interquartile range 0.44 mg·kg(-1) ). No complications were noted, and catheters were left an average of 3 days with a range of 1-5 days with good pain relief. This technical description demonstrates the feasibility of placing PVNB catheters using a transverse in-line ultrasound-guided technique in a wide range of pediatric patients. © 2013 John Wiley & Sons Ltd.

  13. The role of MR angiography before transjugular placement of a portosystemic stent shunt (TIPS)

    International Nuclear Information System (INIS)

    Mueller, M.F.; Siewert, B.; Kim, D.; Edelman, R.R.; Stokes, K.R.; Finn, J.P.

    1994-01-01

    The authors employed magnetic resonance angiography (MRA) to guide catheter placement for transjugular intrahepatic portosystemic stent shunt (TIPS) procedures in 14 of 24 patients, and compared the results to the 10 patients who did not have prior panning based on MRA. Two-dimensional time-of-flight venography was performed during breath holding, and projection venograms were formatted in sagittal, coronal and axial planes. MRA defined venous anatomy sufficiently well to shorten the procedure and helped to minimize invasiveness. With MRA guidance, intrahepatic needle punctures were significantly fewer (without MRA guidance: mean 12.1; with MRA guidance: mean 3.5, p [de

  14. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  15. Intraperitoneally placed Foley catheter via verumontanum initially presenting as a bladder rupture.

    Science.gov (United States)

    Raheem, Omer A; Jeong, Young Beom

    2011-09-01

    Since urethral Foley catheterization is usually easy and safe, serious complications related to this procedure have been rarely reported. Herein, we describe a case of intraperitoneally placed urethral catheter via verumontanum presenting as intraperitoneal bladder perforation in a chronically debilitated elderly patient. A 82-yr-old male patient was admitted with symptoms of hematuria, lower abdominal pain after traumatic Foley catheterization. The retrograde cystography showed findings of intraperitoneal bladder perforation, but emergency laparotomy with intraoperative urethrocystoscopy revealed a tunnel-like false passage extending from the verumontanum into the rectovesical pouch between the posterior wall of the bladder and the anterior wall of the rectum with no bladder injury. The patient was treated with simple closure of the perforated rectovesical pouch and a placement of suprapubic cystostomy tube.

  16. Declotting a Thrombosed Brescia-Cimino Fistula by Manual Catheter-Directed Aspiration of the Thrombus

    International Nuclear Information System (INIS)

    Turmel-Rodrigues, Luc A

    2005-01-01

    Acute thrombosis of native fistulae for hemodialysis occurs more rarely than for prosthetic grafts. The vascular access should be reopened as soon as possible in order to resume regular dialysis and to avoid resorting to a temporary central line. Manual aspiration is one of the numerous methods described in this setting. Clinical examination is essential to rule out local infection, which is the only serious contraindication to percutaneous maneuvers. Two introducer-sheaths are placed in a criss-cross fashion in order to gain access to the venous outflow and to the anastomosis. Access to the venous outflow is performed first in order to check the proximal extent of the thrombosis. Heparin and antibiotics are injected systemically. A similar maneuver is then performed in the direction of the anastomosis. The aspiration phase is then initiated. A 7-9 Fr aspiration catheter is pushed through the 'venous' introducer. Manual aspiration is created through a 50 ml syringe while the catheter is progressively removed with back and forth movements. The catheter and the contents of the syringe are flushed through a gauze on the working table to evaluate the amount of thrombus which has been removed and the maneuver is repeated as often as necessary to remove all the thrombus. Once all the clots located downstream from the venous introducer have been removed, any unmasked underlying stenosis is NOT dilated at this stage since it provides protection against major embolism coming from the inflow. The aspiration catheter is then pushed through the 'arterial' introducer down to the anastomosis in order to aspirate the thrombus located between the tip of the introducer and the anastomosis. Dilatation of unmasked stenoses is finally performed using high-pressure balloons. The holes made by the two introducers are closed using a U-shaped suture with interposition of a short piece of plastic and the patient is sent back to the nephrologists for dialysis

  17. An ovine model of cerebral catheter venography for implantation of an endovascular neural interface.

    Science.gov (United States)

    Oxley, Thomas James; Opie, Nicholas Lachlan; Rind, Gil Simon; Liyanage, Kishan; John, Sam Emmanuel; Ronayne, Stephen; McDonald, Alan James; Dornom, Anthony; Lovell, Timothy John Haynes; Mitchell, Peter John; Bennett, Iwan; Bauquier, Sebastien; Warne, Leon Norris; Steward, Chris; Grayden, David Bruce; Desmond, Patricia; Davis, Stephen M; O'Brien, Terence John; May, Clive N

    2018-04-01

    OBJECTIVE Neural interface technology may enable the development of novel therapies to treat neurological conditions, including motor prostheses for spinal cord injury. Intracranial neural interfaces currently require a craniotomy to achieve implantation and may result in chronic tissue inflammation. Novel approaches are required that achieve less invasive implantation methods while maintaining high spatial resolution. An endovascular stent electrode array avoids direct brain trauma and is able to record electrocorticography in local cortical tissue from within the venous vasculature. The motor area in sheep runs in a parasagittal plane immediately adjacent to the superior sagittal sinus (SSS). The authors aimed to develop a sheep model of cerebral venography that would enable validation of an endovascular neural interface. METHODS Cerebral catheter venography was performed in 39 consecutive sheep. Contrast-enhanced MRI of the brain was performed on 13 animals. Multiple telescoping coaxial catheter systems were assessed to determine the largest wide-bore delivery catheter that could be delivered into the anterior SSS. Measurements of SSS diameter and distance from the motor area were taken. The location of the motor area was determined in relation to lateral and superior projections of digital subtraction venography images and confirmed on MRI. RESULTS The venous pathway from the common jugular vein (7.4 mm) to the anterior SSS (1.2 mm) was technically challenging to selectively catheterize. The SSS coursed immediately adjacent to the motor cortex (SSS. Attempted access with 5-Fr and 6-Fr delivery catheters was associated with longer procedure times and higher complication rates. A 4-Fr catheter (internal lumen diameter 1.1 mm) was successful in accessing the SSS in 100% of cases with no associated complications. Complications included procedure-related venous dissection in two major areas: the torcular herophili, and the anterior formation of the SSS. The

  18. Changing Behavior among Nurses to Track Indwelling Urinary Catheters in Hospitalized Patients

    Directory of Open Access Journals (Sweden)

    Bona Yoon

    2013-01-01

    Full Text Available Catheter-associated urinary tract infections (CAUTIs are preventable complications of hospitalization. An interdisciplinary team developed a curriculum to increase awareness of the presence of indwelling urinary catheters (IUCs in hospitalized patients, addressed practical, primarily nurse-controlled inpatient risk-reduction interventions, and promoted the use of the IUC labels (“tags”. Five thirty-minute educational sessions were cycled over three daily nursing shifts on two inpatient medical floors over a 1-year period; participants were surveyed (n=152 to elicit feedback and provide real-time insight on the learning objectives. Nurse self-reported IUC tagging was early and sustained; after the IUC tag was introduced, there was a significant increase in tagging reported by the end of the block of educational sessions (from 46.2% to 84.6%, P=0.001. Early engagement combined with a targeted educational initiative led to increased knowledge, changes in behavior, and renewed CAUTI awareness in hospitalized patients with IUCs. The processes employed in this small-scale project can be applied to broader, hospitalwide initiatives and to large-scale initiatives for healthcare interventions. As first-line providers with responsibility for the placement and daily maintenance of IUCs, nurses are ideally positioned to implement efforts addressing CAUTIs in the hospital setting.

  19. [Vascular access guidelines for hemodialysis].

    Science.gov (United States)

    Rodríguez Hernández, J A; González Parra, E; Julián Gutiérrez, J M; Segarra Medrano, A; Almirante, B; Martínez, M T; Arrieta, J; Fernández Rivera, C; Galera, A; Gallego Beuter, J; Górriz, J L; Herrero, J A; López Menchero, R; Ochando, A; Pérez Bañasco, V; Polo, J R; Pueyo, J; Ruiz, Camps I; Segura Iglesias, R

    2005-01-01

    Quality of vascular access (VA) has a remarkable influence in hemodialysis patients outcomes. Dysfunction of VA represents a capital cause of morbi-mortality of these patients as well an increase in economical. Spanish Society of Neprhology, aware of the problem, has decided to carry out a revision of the issue with the aim of providing help in comprehensión and treatment related with VA problems, and achieving an homogenization of practices in three mayor aspects: to increase arteriovenous fistula utilization as first vascular access, to increment vascular access monitoring practice and rationalise central catheters use. We present a consensus document elaborated by a multidisciplinar group composed by nephrologists, vascular surgeons, interventional radiologysts, infectious diseases specialists and nephrological nurses. Along six chapters that cover patient education, creation of VA, care, monitoring, complications and central catheters, we present the state of the art and propose guidelines for the best practice, according different evidence based degrees, with the intention to provide help at the professionals in order to make aproppiate decissions. Several quality standars are also included.

  20. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  1. Anesthetic and Airways Management of a Dog with Severe Tracheal Collapse during Intraluminal Stent Placement

    Directory of Open Access Journals (Sweden)

    M. Argano

    2013-01-01

    Full Text Available This case report describes the anesthetic and airways management of a dog affected by 4th degree tracheal collapse and undergoing endoscope-guided intraluminal stent placement. After premedication with acepromazine and butorphanol, general anesthesia was induced with propofol and maintained with intravenous propofol and butorphanol in constant rate infusion. During intraluminal stent placement, oxygen was supplemented by means of a simple and inexpensive handmade device, namely, a ureteral catheter inserted into the trachea and connected to an oxygen source, which allowed for the maintenance of airways’ patency and adequate patient’s oxygenation, without decreasing visibility in the surgical field or interfering with the procedure. The use of the technique described in the present paper was the main determinant of the successful anesthetic management and may be proposed for similar critical cases in which surgical manipulation of the tracheal lumen, which may potentially result in hypoxia by compromising airways patency, is required.

  2. Bacillus Cereus catheter related bloodstream infection in a patient in a patient with acute lymphblastic leukemia

    Directory of Open Access Journals (Sweden)

    Lütfiye Öksüz

    2012-01-01

    Full Text Available Bacillus cereus infection is rarely associated with actual infection and for this reason single positive blood culture is usually regarded as contamination . However it may cause a number of infections, such catheter-related blood stream infections. Significant catheter-related bloodstream infections (CRBSI caused by Bacillus spp. are mainly due to B.cereus and have been predominantly reported in immunocompromised hosts1 . Catheter removal is generally advised for management of infection. In this report, catheter-related bacteremia caused by B.cereus in a patient with acute lymphoblastıc leukemia (ALL in Istanbul Medical Faculty was presented.A 44-year old man presented with fatigue, weight loss, epistaxis and high fever. A double-lumen Hickman–catheter (Bard 12.0 Fr, Round Dual Lumen was inserted by surgical cut-down to access the right subclavian vein which would be necessary for allogeneic stem cell transplantation. Three weeks later the patient presented with high fever and headache. Bacillus spp. was isolated from the cathether while blood culture obtained from the peripheral vein remained negative. The bacterial identification was confirmed as B.cereus using VITEK identification system It has been reported Bacillus cereus septicemia may be fatal in immunocompromised hosts despite broad-spectrum appropriate treatment10. Catheter removal is essential for prevention of recurrent bacteremia. Long-term cathater salvage should be reserved for appropriate patient group.

  3. Totally implantable vascular access device (TIVAD) placement: a modified technique that takes post-procedure aesthetic aspects into account.

    Science.gov (United States)

    Liberale, Gabriel

    2017-04-01

    Major progress has been made in breast cancer reconstruction surgery. The standard technique for totally implanted vascular access device (TIVAD) implantation generally requires an incision for port insertion on the anterior part of the thorax that leaves a scar in the middle of the neckline in patients who have undergone mastectomy with complex breast reconstruction. The aim of this technical note is to report our revised surgical technique for TIVAD placement. In patients with breast cancer, we take a lateralized approach, performing an oblique incision on the lowest part of the deltopectoral groove. This allows us to introduce the port and to place it on the anterolateral part of the thorax, thus avoiding an unaesthetic scar on the anterior part of the thorax. Our modified technique for TIVAD implantation is described.

  4. Hemodialysis catheter insertion: is increased PO2 a sign of arterial cannulation? A case report.

    Science.gov (United States)

    Chirinos, Julio C; Neyra, Javier A; Patel, Jiten; Rodan, Aylin R

    2014-07-29

    Ultrasound-guided Central Venous Catheterization (CVC) for temporary vascular access, preferably using the right internal jugular vein, is widely accepted by nephrologists. However CVC is associated with numerous potential complications, including death. We describe the finding of a rare left-sided partial anomalous pulmonary vein connection during central venous catheterization for continuous renal replacement therapy (CRRT). Ultrasound-guided cannulation of a large bore temporary dual-lumen Quinton-Mahurkar catheter into the left internal jugular vein was performed for CRRT initiation in a 66 year old African-American with sepsis-related oliguric acute kidney injury. The post-procedure chest X-ray suggested inadvertent left carotid artery cannulation. Blood gases obtained from the catheter showed high partial pressure of oxygen (PO2) of 140 mmHg and low partial pressure of carbon dioxide (PCO2) of 22 mmHg, suggestive of arterial cannulation. However, the pressure-transduced wave forms appeared venous and Computed Tomography Angiography located the catheter in the left internal jugular vein, but demonstrated that the tip of the catheter was lying over a left pulmonary vein which was abnormally draining into the left brachiocephalic (innominate) vein rather than into the left atrium. Although several mechanical complications of dialysis catheters have been described, ours is one of the few cases of malposition into an anomalous pulmonary vein, and highlights a sequential approach to properly identify the catheter location in this uncommon clinical scenario.

  5. Comparative Analysis of the Paravertebral Analgesic Pump Catheter with the Epidural Catheter in Elderly Trauma Patients with Multiple Rib Fractures.

    Science.gov (United States)

    Shapiro, Brian S; Wasfie, Tarik; Chadwick, Mathew; Barber, Kimberly R; Yapchai, Raquel

    2017-04-01

    Presently, trauma guidelines recommend epidural analgesia as the optimal modality of pain relief from rib fractures. They are not ideally suited for elderly trauma patients and have disadvantages including bleeding risk. The paravertebral analgesic pump (PVP) eliminates such disadvantages and includes ease of placement in the trauma setting. This study compares pain control in patients treated by EPI versus PVP. This is a retrospective, historical cohort study comparing two methods of pain management in the trauma setting. Before 2010, patients who had epidural catheters (EPI) placed for pain control were compared with patients after 2010 in which the PVP was used. All patients had multiple rib fractures as diagnosed by CT scan. Analysis was adjusted for age, number of fractures, and comorbid conditions. Multiple linear regression analysis was conducted to compare average reported pain. A total of 110 patients, 31 PVP and 79 epidural catheters, were included in the study. Overall mean age was 65 years. The mean Injury Severity Score was 12.0 (EPI) and 11.1 (PVP). Mean number rib fractures was 4.29 (EPI) and 4.71 (PVP). PVP was associated with a 30 per cent greater decrease in pain than that seen with EPI (6.0-1.9 vs 6.4-3.4). After controlling for age, Injury Severity Score, and number of rib fractures, there were no differences in intensive care unit or total length of stay (P = 0.35) or in pain score (3.76 vs 3.56, P = 0.64). In conclusion, the PVP compares well with epidural analgesia in older trauma patients yet is safe, well tolerated, and easily inserted.

  6. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  7. Long-term facial artery catheter implantation for serial arterial blood sampling and invasive arterial blood pressure measurement in horses.

    Science.gov (United States)

    Dias, Deborah Penteado Martins; Teixeira, Luisa Gouvêa; Canola, Paulo Aléscio; Albernaz, Raquel Mincarelli; Marques, José Antônio; Neto, José Corrêa de Lacerda

    2012-06-01

    The purpose of this investigation was to evaluate surgical catheter implantation in the facial artery of horses and the long-term maintenance of such arteries using heparin and ascorbic acid as filling solution. Nine horses were implanted with a polyurethane catheter. The catheters were flushed with a heparin/ascorbic acid solution every 8h and remained patent for 25 days. Arterial blood samples were collected twice a day, and one exercise test that included serial blood samples and arterial pressure recordings was performed on a treadmill. Polyurethane catheters surgically implanted in the facial artery can be kept patent by filling with a heparin/ascorbic acid solution and provide convenient invasive arterial access in horses which is suitable for use for serial blood sampling and blood pressure recordings, even during exercise on treadmill. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. COST ANALYSIS OF PERIPHERALLY INSERTED CENTRAL CATHETER IN PEDIATRIC PATIENTS.

    Science.gov (United States)

    Dong, Zhaoxin; Connolly, Bairbre L; Ungar, Wendy J; Coyte, Peter C

    2018-01-01

    A peripherally inserted central catheter (PICC) is a useful option in providing secure venous access, which enables patients to be discharged earlier with the provision of home care. The objective was to identify the costs associated with having a PICC from a societal perspective, and to identify factors that are associated with total PICC costs. Data were obtained from a retrospective cohort of 469 hospitalized pediatric patients with PICCs inserted. Both direct and indirect costs were estimated from a societal perspective. Insertion costs, complication costs, nurse and physician assessment costs, inpatient ward costs, catheter removal costs, home care costs, travel costs, and the cost associated with productivity losses incurred by parents were included in this study. Based on catheter dwell time, the median total cost associated with a PICC per patient per day (including inpatient hospital costs) was $3,133.5 ($2,210.7-$9,627.0) in 2017 Canadian dollars ($1.00USD = $1.25CAD in 2017). The adjusted mean cost per patient per day was $2,648.2 ($2,402.4-$2,920.4). Excluding inpatient ward costs, the median total and adjusted costs per patient per day were $198.8 ($91.8-$2,475.8) and $362.7($341.0-$386.0), respectively. Younger age, occurrence of complications, more catheter dwell days, wards with more intensive care, and the absence of home care were significant factors associated with higher total PICC costs. This study has demonstrated the costs associated with PICCs. This information may be helpful for healthcare providers to understand PICC related cost in children and resource implications.

  9. Balloon-assisted coiling through a 5-French system

    International Nuclear Information System (INIS)

    White, J. Bradley; Layton, Kennith F.; Kallmes, David F.; Cloft, Harry J.

    2007-01-01

    We present a catheter technique that utilizes a 5F system for the purpose of balloon-assisted coiling in the setting of intracranial aneurysms. A standard 5F short sheath is placed in the common femoral artery, and a 5F diagnostic catheter is placed through the sheath and used for selective vessel angiography. When endovascular intervention is pursued, the diagnostic catheter is placed in the appropriate vessel and systemic heparinization is ensured. Over an exchange length wire, the 5F vertebral catheter and 5F short sheath are exchanged for a 5F Shuttle (Cook) sheath. We then routinely place a 10, 14 or 18 microcatheter over an appropriately gauged microguidewire into the aneurysm. As needed, balloon catheters are then placed across the neck of the aneurysm for remodeling purposes. During the course of the procedure, control angiography is performed through the Shuttle sheath. Following the placement of coils, the microcatheter and balloon catheter are removed and a final biplane image is obtained via the 5F Shuttle sheath. This technique has been employed in 15 patients who required balloon-assisted coiling of an intracranial aneurysm. There were no technical difficulties or arterial access site complications from the procedures. Catheter mobility and torque were not affected, nor was the quality of our imaging. We conclude that this small-diameter system provides ample ''room'' for catheter placement and interventional treatment while reducing the known risks of postprocedural complications. Angiographic images remain excellent and are comparable to those obtained by larger catheters. (orig.)

  10. Prevention of catheter-related blood stream infection.

    Science.gov (United States)

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  11. Transposition of cephalic vein to rescue hemodialysis access arteriovenous fistula and treat symptomatic central venous obstruction

    Directory of Open Access Journals (Sweden)

    Felipe Jose Skupien

    2014-03-01

    Full Text Available It is known that stenosis or central venous obstruction affects 20 to 50% of patients who undergo placement of catheters in central veins. For patients who are given hemodialysis via upper limbs, this problem causes debilitating symptoms and increases the risk of loss of hemodialysis access. We report an atypical case of treatment of a dialysis patient with multiple comorbidities, severe swelling and pain in the right upper limb (RUL, few alternative sites for hemodialysis vascular access, a functioning brachiobasilic fistula in the RUL and severe venous hypertension in the same limb, secondary to central vein occlusion of the internal jugular vein and right brachiocephalic trunk. The alternative surgical treatment chosen was to transpose the RUL cephalic vein, forming a venous necklace at the anterior cervical region, bypassing the site of venous occlusion. In order to achieve this, we dissected the cephalic vein in the right arm to its junction with the axillary vein, devalved the cephalic vein and anastomosed it to the contralateral external jugular vein, providing venous drainage to the RUL, alleviating symptoms of venous hypertension and preserving function of the brachiobasilic fistula.

  12. Subarachnoid and basal cistern navigation through the sacral hiatus with guide wire assistance.

    Science.gov (United States)

    Layer, Lauren; Riascos, Roy; Firouzbakht, Farhood; Amole, Adewumi; Von Ritschl, Rudiger; Dipatre, Pier; Cuellar, Hugo

    2011-07-01

    Intraspinal navigation with catheters and fiberscopes has shown feasible results for diagnosis and treatment of intraspinal and intracranial lesions. The most common approach, lumbar puncture, has allowed access to the spinal cord, however, coming with the difficulties of fiberscope damage and decreased torque for guidance. Our objective in this study is to allow an alternate access, the sacral hiatus, with guide wire assistance into the subarachnoid and intracranial structures, while easing the angle of entry and increasing torque. We advanced catheters with guide wire and fluoroscopy assistance into the sacral hiatus of three cadavers. After entry, the thecal sac was punctured and the catheter with guide wire was advanced rostrally until positioned in the basal cisterns of the brain. We confirmed catheter placement with contrast injection, autopsy, and dissection. In our study, the sacral hiatus was easily accessed, but resistance was found when attempting to puncture the thecal sac. The advancement of the catheter with guide wire assistance glided easily rostrally until some mild resistance was discovered at entry into the foramen magnum. With redirection, all catheters passed with ease into the basal cisterns. Positioning was confirmed with contrast injection with fluoroscopy evidence, autopsy, and dissection. There was no macroscopic or microscopic evidence of damage to the spinal roots, spinal cord, or cranial nerves. The sacral hiatus with guide wire assistance is an accessible conduit for uncomplicated entry into the subarachnoid and basal cistern space without damaging surrounding structures.

  13. Gaining Access.

    Science.gov (United States)

    Wand, Sean; Thermos, Adam C.

    1998-01-01

    Explains the issues to consider before a college decides to purchase a card-access system. The benefits of automation, questions involving implementation, the criteria for technology selection, what typical card technology involves, privacy concerns, and the placement of card readers are discussed. (GR)

  14. Endovascular Revascularization of Chronically Thrombosed Arteriovenous Fistulas and Grafts for Hemodialysis: A Retrospective Study in 15 Patients With 18 Access Sites

    International Nuclear Information System (INIS)

    Weng Meijui; Chen, Matt Chiung-Yu; Chi Wenche; Liu Yichun; Liang, Huei-Lung; Pan, Huay-Ben

    2011-01-01

    . Percutaneous resurrection of mummy vascular access sites for hemodialysis is technically feasible with high clinical success rates. In selected patients, resurrection of mummy access sites provides long-discarded access sites one more chance to be used for hemodialysis in an effort to preserve potential extremity sites for future access-site placement and to prevent long-term catheter indwelling.

  15. Preparing midwifery students for practice: The value of elective placements in enhancing midwifery practice.

    Science.gov (United States)

    Bradshaw, Carmel; Barry, Maebh; Noonan, Maria; Tighe, Sylvia Murphy; Atkinson, Sandra

    2018-04-01

    An elective placement where students are facilitated to access different models of midwifery care was included in the 18 month Higher Diploma Midwifery programme in 2008 in a university in Ireland. All students since then have had the opportunity to experience this placement which is advocated by the regulatory board for Nursing and Midwifery in Ireland (NMBI). This paper details the integration of an elective placement referred to as an 'observation week' into the 18 month midwifery programme. It includes a description of the organisation of the observation week, a summary of services accessed by midwifery students, student evaluation of their experience and mechanisms for feedback of these experiences to our partners in clinical practice. The benefits and the challenges of the observation week are considered with reference to the published literature. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

    International Nuclear Information System (INIS)

    Kröpil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Blondin, Dirk; Winter, Joachim; Scherer, Axel; Fürst, Günter

    2011-01-01

    We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 ± 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

  17. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    Science.gov (United States)

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  18. Greece reports prototype intervention with first peripherally inserted central catheter: case report and literature review.

    Science.gov (United States)

    Konstantinou, Evangelos A; Stafylarakis, Emmanuil; Kapritsou, Maria; Mitsos, Aristotelis P; Fotis, Theofanis G; Kiekkas, Panagiotis; Mariolis-Sapsakos, Theodoros; Argyras, Eriphyli; Nomikou, Irini Th; Dimitrakopoulos, Antonios

    2012-09-01

    Placement of peripherally inserted central catheters (PICCs), definitely offers a clear advantage over any other method regarding central venous catheterization. Its ultrasonographic orientation enhances significantly its accuracy, safety and efficacy, making this method extremely comfortable for the patient who can continue his or her therapy even in an outpatient basis. We present the first reported case of a PICCS insertion in Greece, which has been performed by a university-degree nurse. The aim of this review of literature was to present the evolution in nursing practice in Greece. A PICC was inserted in a 77-year-old male patient suffering from a recent chemical pneumonia with a history of Alzheimer's disease. A description of all the technical details of this insertion is reported, focusing on the pros and cons of the method and a thorough review of the history and advances in central venous catheterization throughout the years is also presented. PICCs provide long-term intravenous access and facilitate the delivery of extended antibiotic therapy, chemotherapy and total parenteral nutrition. We strongly believe that PICCs are the safest and most effective method of peripherally inserted central venous catheterization. Larger series are necessary to prove the above hypothesis, and they are under construction by our team. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.

  19. Repositioning and Leaving In Situ the Central Venous Catheter During Percutaneous Treatment of Associated Superior Vena Cava Syndrome: A Report of Eight Cases

    International Nuclear Information System (INIS)

    Stockx, Luc; Raat, Henricus; Donck, Jan; Wilms, Guy; Marchal, Guy

    1999-01-01

    Purpose: To describe a combined procedure of repositioning and leaving in situ a central venous catheter followed by immediate percutaneous treatment of associated superior vena cava syndrome (SVCS). Methods: Eight patients are presented who have central venous catheter-associated SVCS (n = 6 Hickman catheters, n = 2 Port-a-cath) caused by central vein stenosis (n = 4) or concomitant thrombosis (n = 4). With the use of a vascular snare introduced via the transcubital or transjugular approach, the tip of the central venous catheter could be engaged, and repositioned after deployment of a stent in the innominate or superior vena cava. Results: In all patients it was technically feasible to reposition the central venous catheter and treat the SVCS at the same time. In one patient flipping of the Hickman catheter in its original position provoked dislocation of the released Palmaz stent, which could be positioned in the right common iliac vein. Conclusion: Repositioning of a central venous catheter just before and after stent deployment in SVCS is technically feasible and a better alternative than preprocedural removal of the vascular access

  20. Preoperative optimization of multi-organ failure following acute myocardial infarction and ischemic mitral regurgitation by placement of a transthoracic intra-aortic balloon pump.

    Science.gov (United States)

    Umakanthan, Ramanan; Dubose, Robert; Byrne, John G; Ahmad, Rashid M

    2010-10-01

    The management of acute myocardial infarction with resultant acute ischemic mitral regurgitation and acute multi-organ failure can prove to be a very challenging scenario. The presence of concomitant vascular disease can only serve to further compromise the complexity of the situation. We demonstrate a new indication for the transthoracic intra-aortic balloon pump as a preoperative means of unloading the heart and improving clinical outcome in such high-risk patients with severe vascular disease. We present the case of a 75-year-old man with a history of severe vascular disease who was transferred emergently to Vanderbilt University Medical Center with an acute inferolateral wall myocardial infarction resulting in severe acute ischemic mitral regurgitation and acute multi-organ failure. He presented with shock liver (serum glutamic-oxaloacetic transaminase [SGOT] of 958), renal failure (creatinine of 3.0), and respiratory failure with a pH of 7.18. Emergent cardiac catheterization revealed 100% occlusion of the left circumflex artery as well as severe ileofemoral disease. The advanced nature of his ileofemoral disease was such that the arterial access catheter occluded the right femoral artery. The duration of time that the catheter was in the artery led to transient limb ischemia with an elevation of his creatine phosphokinase (CPK) to 10,809. Balloon angioplasty followed by stent placement was successfully performed, which restored flow to the coronary vessel. Given the grave nature of the patient's condition, we were very concerned that immediate operative intervention for his condition would entail prohibitively high risk. In fact, the Society of Thoracic Surgeons predicted risk adjusted mortality was calculated to be 56%. In order to minimize patient mortality and morbidity, it was critical to help restore perfusion and organ recovery. Therefore, we decided that the chances for this patient's survival would improve if his condition could be optimized by

  1. A review of an anaesthetic led vascular access list.

    Science.gov (United States)

    Galloway, S; Sharma, A; Ward, J; Bodenham, A R

    2005-08-01

    The demand for insertion of long-term central venous (Hickman type) catheters is thought to be increasing. Organisation is required to meet this demand in a safe and efficient manner. This report reviews the results from a dedicated, anaesthetic led vascular access list over the initial 61-month period. One thousand procedures were performed. Nine hundred and twenty catheters were inserted under local anaesthesia, with or without intravenous sedation and analgesia. Eighty catheters were removed. All procedures were performed during a dedicated once weekly, morning list. A total of 53% of all procedures were performed on a day-case basis, 43% on in-patients. Only 1.5% of patients required an unexpected overnight stay (usually medically unfit patients). There were 81 (9%) cancellations on the day of procedure due to neutropaenia, pneumonia or urinary tract infections. Ultrasound guidance was used initially selectively in 14%, latterly in 100% of procedures and fluoroscopy in all insertions to confirm or adjust catheter position. This service has been well received by patients and oncology services. In addition it provides an interesting area of practice for anaesthetists and an ideal environment for teaching more advanced aspects of central venous access. It may provide a template of service for other centres.

  2. Bacillus Cereus catheter related bloodstream infection in a patient in a patient with acute lymphblastic leukemia

    Directory of Open Access Journals (Sweden)

    Lütfiye Öksüz

    2012-01-01

    Full Text Available

    Bacillus cereus infection is rarely associated with actual infection and for this reason single positive blood culture is usually regarded as contamination . However it may cause a number of infections, such catheter-related blood stream infections. Significant catheter-related bloodstream infections (CRBSI caused by Bacillus spp. are mainly due to B.cereus and have been predominantly reported in immunocompromised hosts1 . Catheter removal is generally advised for management of infection. In this report, catheter-related bacteremia caused by B.cereus in a patient with acute lymphoblastıc leukemia (ALL in Istanbul Medical Faculty was presented.A 44-year old man presented with fatigue, weight loss, epistaxis and high fever. A double-lumen Hickman–catheter (Bard 12.0 Fr, Round Dual Lumen was inserted by surgical cut-down to access the right subclavian vein which would be necessary for allogeneic stem cell transplantation. Three weeks later the patient presented with high fever and headache. Bacillus spp. was isolated from the cathether while blood culture obtained from the peripheral vein remained negative. The bacterial identification was confirmed as B.cereus using VITEK identification system

    It has been reported Bacillus cereus septicemia may be fatal in immunocompromised hosts despite broad-spectrum appropriate treatment10. Catheter removal is essential for prevention of recurrent bacteremia. Long-term cathater salvage should be reserved for appropriate patient group.

  3. Pleurodesis Using Mistletoe Extract Delivered via a Spray Catheter during Semirigid Pleuroscopy for Managing Symptomatic Malignant Pleural Effusion.

    Science.gov (United States)

    Eom, Jung Seop; Ahn, Hyo Yeong; Mok, Jeong Ha; Lee, Geewon; Jo, Eun-Jung; Kim, Mi-Hyun; Lee, Kwangha; Kim, Ki Uk; Park, Hye-Kyung; Lee, Min Ki

    Talc poudrage during thoracoscopy is considered the standard procedure for patients with symptomatic malignant pleural effusion (MPE). Until now, no alternative technique other than talc poudrage for pleurodesis during medical thoracoscopy has been proposed. Liquid sclerosants, such as mistletoe extract, have been sprayed evenly into the pleural cavity during semirigid pleuroscopy for chemical pleurodesis. We conducted a retrospective study using the database of semirigid pleuroscopy to identify the usefulness of pleurodesis using a mistletoe extract delivered via a spray catheter during semirigid pleuroscopy for symptomatic MPE. All consecutive patients with symptomatic MPE who underwent semirigid pleuroscopy from October 2015 to September 2016 were registered. The responses were evaluated using chest X- ray or computed tomography 4 weeks after pleurodesis. The study included 43 patients who underwent pleurodesis with mistletoe extract via a spray catheter during semirigid pleuroscopy. Complete and partial responses were seen in 21 (49%) and 19 (44%) patients, respectively. The median duration of chest tube placement after pleurod-esis was 7 days (range 6-8 days) in the 40 patients with complete or partial responses. No cases of severe hemorrhage, empyema formation, respiratory failure, or procedure-related mortality were observed in the subjects at 4 weeks after semirigid pleuroscopy. Pleurodesis with mistletoe extract delivered via a spray catheter during semirigid pleuroscopy is a safe and effective procedure for managing symptomatic MPE. © 2017 S. Karger AG, Basel.

  4. Antibiotic resistance patterns of bacteria isolated from indwelling Foley catheters following tube cystostomy in goats with obstructive urolithiasis.

    Science.gov (United States)

    Chigerwe, Munashe; Mavangira, Vengai; Byrne, Barbara A; Angelos, John A

    2017-05-01

    Tube cystostomy is a surgical method used for managing obstructive urolithiasis and involves placement of a Foley catheter into the urinary bladder. We identified and evaluated the antibiotic resistance patterns of bacteria isolated from indwelling Foley catheters following tube cystostomy in goats with obstructive urolithiasis. Urine samples collected over a 10-y period from catheter tips at the time of removal were submitted for bacteriologic culture and antibiotic susceptibility testing. Resistance patterns to antibiotics, trends in the resistance patterns over the study period, and the probability of a bacterial isolate being resistant as a function of the identity of the isolate and antibiotic tested were determined. A total of 103 urine samples from 103 male goats with obstructive urolithiasis managed surgically with tube cystostomy were included in the study. Aerococcus (36.9%) and Enterococcus (30.1%) were isolated most frequently. The susceptibility patterns of all bacteria isolated did not change over the study period ( p > 0.05). Proportions of isolates resistant to 1, 2, and ≥3 antibiotics were 36.9%, 18.5%, and 23.3%, respectively. Thus, 41.8% of bacterial isolates were resistant to 2 or more antibiotics tested. The probability of Aerococcus spp., Escherichia coli, and Pseudomonas aeruginosa isolates to be resistant to ampicillin, ceftiofur, erythromycin, penicillin, or tetracycline ranged from 0.59 to 0.76.

  5. Validating the Use of AP® Exam Scores for College Course Placement. Research Report 2013-2

    Science.gov (United States)

    Patterson, Brian F.; Ewing, Maureen

    2013-01-01

    The Advanced Placement Program® (AP®) was created to provide access to rigorous, college-level curricula to motivated and prepared high school students. This study evaluated whether the AP Exam scores from the summative exams associated with 10 courses were valid for the placement of students into higher-level college courses in the subject area…

  6. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  7. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  8. Can children undergoing ophthalmologic examinations under anesthesia be safely anesthetized without using an IV line?

    Directory of Open Access Journals (Sweden)

    Vigoda M

    2011-04-01

    Full Text Available Michael M Vigoda, Azeema Latiff, Timothy G Murray, Jacqueline L Tutiven, Audina M Berrocal, Steven GayerBascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USAPurpose: To document that with proper patient and procedure selection, children undergoing general inhalational anesthesia for ophthalmologic exams (with or without photos, ultrasound, laser treatment, peri-ocular injection of chemotherapy, suture removal, and/or replacement of ocular prosthesis can be safely anesthetized without the use of an intravenous (IV line. Children are rarely anesthetized without IV access placement. We performed a retrospective study to determine our incidence of IV access placement during examinations under anesthesia (EUA and the incidence of adverse events that required intraoperative IV access placement.Methods: Data collected from our operating room (OR information system includes but is not limited to diagnosis, anesthesiologist, surgeon, and location of IV catheter (if applicable, patient’s date of birth, actual procedure, and anesthesia/procedure times. We reviewed the OR and anesthetic records of children (>1 month and <10 years who underwent EUAs between January 1, 2003 and May 31, 2009. We determined the percentage of children who were anesthetized without IV access placement, as well as the incidence of any adverse events that required IV access placement, intraoperatively.Results: We analyzed data from 3196 procedures performed during a 77-month period. Patients’ ages ranged from 1 month to 9 years. Overall, 92% of procedures were performed without IV access placement. Procedure duration ranged from 1–39 minutes. Reasons for IV access placement included parental preference for antinausea medication and/or attending preference for IV access placement. No child who underwent anesthesia without an IV line had an intraoperative adverse event requiring insertion of an IV line.Conclusion: Our data suggest that for

  9. 21 CFR 876.5030 - Continent ileostomy catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continent ileostomy catheter. 876.5030 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5030 Continent ileostomy catheter. (a) Identification. A continent ileostomy catheter is a flexible tubular device used as a form...

  10. FAQs about Catheter-Associated Urinary Tract Infection

    Science.gov (United States)

    ... do so. o Avoid disconnecting the catheter and drain tube. This helps to pre - vent germs from getting into the catheter tube. o The catheter is secured to the leg to prevent pulling on the ... regularly. The drainage spout should not touch any - thing while emptying ...

  11. The dangers of long-term catheter drainage.

    Science.gov (United States)

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  12. Keyword: Placement

    Science.gov (United States)

    Cassuto, Leonard

    2012-01-01

    The practical goal of graduate education is placement of graduates. But what does "placement" mean? Academics use the word without thinking much about it. "Placement" is a great keyword for the graduate-school enterprise. For one thing, its meaning certainly gives a purpose to graduate education. Furthermore, the word is a portal into the way of…

  13. Biological safety evaluation of the modified urinary catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczuk, Dorota, E-mail: dorota.kowalczuk@umlub.pl [Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin (Poland); Przekora, Agata; Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2015-04-01

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death.

  14. Transcatheter closure of a large patent ductus arteriosus using jugular access in an infant.

    Science.gov (United States)

    Fernandes, Precylia; Assaidi, Anass; Baruteau, Alban-Elouen; Fraisse, Alain

    2018-03-01

    Trans-catheter device closure of patent ductus arteriosus (PDA) via femoral route is the commonly used, safe and effective procedure. Trans-jugular approach has been successfully used in older children with interrupted inferior vena cava. We report a case of successful occlusion of PDA using Amplatzer duct occluder (ADO) via trans-jugular approach following difficulties encountered in gaining femoral venous access. A 6-month-old male infant, weighing 8 kg was admitted for percutaneous catheter closure of PDA. Echocardiogram showed a 4.5 mm duct and left heart dilatation. Femoral venous access was not possible; therefore, we decided to use a trans-jugular approach. The duct was occluded using 8/6 mm ADO. Successful closure of the duct was confirmed with an aortogram. Post procedure echocardiogram showed no residual shunt across the duct. We highlight that trans-catheter closure of PDA using jugular venous access is safe and effective even in infants.

  15. Zero-fluoroscopy cryothermal ablation of atrioventricular nodal re-entry tachycardia guided by endovascular and endocardial catheter visualization using intracardiac echocardiography (Ice&ICE Trial).

    Science.gov (United States)

    Luani, Blerim; Zrenner, Bernhard; Basho, Maksim; Genz, Conrad; Rauwolf, Thomas; Tanev, Ivan; Schmeisser, Alexander; Braun-Dullaeus, Rüdiger C

    2018-01-01

    Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions. © 2017 Wiley Periodicals, Inc.

  16. Clinical predictors of port infections within the first 30 days of placement.

    Science.gov (United States)

    Bamba, Ravinder; Lorenz, Jonathan M; Lale, Allison J; Funaki, Brian S; Zangan, Steven M

    2014-03-01

    To identify risk factors for port infections within 30 days of placement. A retrospective chart review of port placements from 2002-2009 was conducted. Patients who had port removals secondary to infection within the first 30 days of placement were included. This group of patients was compared with a control group of patients with ports with no evidence of infection. For every one patient with a port infection, two control subjects were chosen of the same gender and new port placement during the same month as the corresponding patient with an infected port. From 2002-2009, 4,404 ports were placed. Of the 4,404 patients, 33 (0.7%) were found to have a port infection within 30 days of placement. Compared with the control group, the early infection group had a higher prevalence of leukopenia (21.2% vs 6.1%, P = .039) and thrombocytopenia (33% vs 12%, P = .0158). There was also a higher prevalence of an inpatient hospital stay during port placement and high international normalized ratio in the early infection group. Low preoperative white blood cell and platelet counts were risk factors for early infection. Abnormal coagulation profiles and inpatient access of ports after placement could be additional risk factors. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  17. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    Directory of Open Access Journals (Sweden)

    Janete de Souza Urbanetto

    Full Text Available ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC and following their removal - (post-infusion phlebitis in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective.

  18. Navigation of guidewires and catheters in the body during intervention procedures : A review of computer-based models

    NARCIS (Netherlands)

    Sharei Amarghan, H.; Alderliesten, Tanja; van den Dobbelsteen, J.J.; Dankelman, J.

    2018-01-01

    Guidewires and catheters are used during minimally invasive interventional procedures to traverse in vascular system and access the desired position. Computer models are increasingly being used to predict the behavior of these instruments. This information can be used to choose the right

  19. Evaluation of the Necessity of Port Fixation in Central Venous Port Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Su; Kim, Hyung Pil [Inje University Pusan Paik Hospital, Busan (Korea, Republic of); Bae, Jae Ik; Won, Je Hwan [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2010-06-15

    The technical success and complications were especially focused on and evaluated the need for fixation of a port under fluoroscopic guidance placement of the totally implantable central venous access ports for long term central venous access. Two hundred eighty nine consecutive patients (170 men, 119 women, mean age: 52-year-old) who underwent venous port implantation for the administration of chemotherapy were followed over a 1-month period. The procedures were performed in the angiographic suite by an interventional radiologist and all access was through the right jugular vein, except for the patients who had undergone a right mastectomy. The procedures were performed in the following order: 1) venous puncture, 2) making a pocket, 3) catheter tunneling, 4) port insertion, 5) catheter sizing, and 6) insertion. A port which was connected to the tunneled catheter was inserted into the minimally sized subcutaneous pocket with the aid of a small retractor. A follow-up was performed with medical records and chest radiographs. The follow-up period for evaluating the venous port ranged from 59 to 329 days (mean: 175 days) The procedures performed to gain right jugular vein access were successful without difficulty in all cases. The 18 patients that underwent procedures to gain left jugular vein access encountered some difficulty upon insertion of a catheter into the SVC due to encountering the tortuous left brachiocephalic vein. No complications occurred during and immediately after the procedure. In one case the port chamber rotated within the subcutaneous pocket; however, no catheter migration or malfunction occurred. If port insertion was followed by catheter insertion, the port chamber can be tightly implanted in the minimally sized pocket. This would avoid the need for fixation of the catheter to the port chamber leading into the pocket

  20. Time-dependent analysis of incidence, risk factors and clinical significance of pneumothorax after percutaneous lung biopsy.

    Science.gov (United States)

    Lim, Woo Hyeon; Park, Chang Min; Yoon, Soon Ho; Lim, Hyun-Ju; Hwang, Eui Jin; Lee, Jong Hyuk; Goo, Jin Mo

    2018-03-01

    To evaluate the time-dependent incidence, risk factors and clinical significance of percutaneous lung biopsy (PLB)-related pneumothorax. From January 2012-November 2015, 3,251 patients underwent 3,354 cone-beam CT-guided PLBs for lung lesions. Cox, logistic and linear regression analyses were performed to identify time-dependent risk factors of PLB-related pneumothorax, risk factors of drainage catheter insertion and those of prolonged catheter placement, respectively. Pneumothorax occurred in 915/3,354 PLBs (27.3 %), with 230/915 (25.1 %) occurring during follow-ups. Risk factors for earlier occurrence of PLB-related pneumothorax include emphysema (HR=1.624), smaller target (HR=0.922), deeper location (HR=1.175) and longer puncture time (HR=1.036), while haemoptysis (HR=0.503) showed a protective effect against earlier development of pneumothorax. Seventy-five cases (8.2 %) underwent chest catheter placement. Mean duration of catheter placement was 3.2±2.0 days. Emphysema (odds ratio [OR]=2.400) and longer puncture time (OR=1.053) were assessed as significant risk factors for catheter insertion, and older age (parameter estimate=1.014) was a predictive factor for prolonged catheter placement. PLB-related pneumothorax occurred in 27.3 %, of which 25.1 % developed during follow-ups. Smaller target size, emphysema, deeply-located lesions were significant risk factors of PLB-related pneumothorax. Emphysema and older age were related to drainage catheter insertion and prolonged catheter placement, respectively. • One-fourth of percutaneous lung biopsy (PLB)-related pneumothorax occurs during follow-up. • Smaller, deeply-located target and emphysema lead to early occurrence of pneumothorax. • Emphysema is related to drainage catheter insertion for PLB-related pneumothorax. • Older age may lead to prolonged catheter placement for PLB-related pneumothorax. • Tailored management can be possible with time-dependent information of PLB-related pneumothorax.

  1. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  2. Obstruction of peritoneal dialysis catheter is associated with catheter type and independent of omentectomy: A comparative data analysis from a transplant surgical and a pediatric surgical department.

    Science.gov (United States)

    Radtke, Josephine; Schild, Raphael; Reismann, Marc; Ridwelski, Robert-Richard; Kempf, Caroline; Nashan, Bjoern; Rothe, Karin; Koch, Martina

    2018-04-01

    Peritoneal dialysis (PD) catheter occlusion is a common complication with up to 36% of catheter obstructions described in the literature. We present a comparison of complications and outcome after implantation of PD catheters in a transplant surgical and a pediatric surgical department. We retrospectively analyzed 154 PD catheters, which were implanted during 2009-2015 by transplant surgeons (TS, University Medical Center Hamburg-Eppendorf, Germany, n=85 catheters) and pediatric surgeons (PS, Charité University Medicine Berlin, Germany, n=69 catheters) in 122 children (median (range) age 3.0 (0.01-17.1) years) for acute (n=65) or chronic (n=89) renal failure. All catheters were one-cuffed or double-cuffed curled catheters, except that straight catheters were implanted into smaller children (n=19) by TS in Hamburg. Patient characteristics and operation technique did not differ between the departments. Peritonitis was the most common complication (33 catheters, 21.4%). Leakage (n=18 catheters, 11.7%) occurred more often in children weighing <10kg (p<0.001). The incidence of obstruction and dysfunction was significantly higher in catheters used in PS than catheters used in TS (30.4% vs. 11.8%, p=0.004). Omentectomy did not reduce the incidence of catheter obstruction (p=1.0). Perforation at the catheter tips was larger and appeared to be rougher in catheters used in PS than the catheters in TS. The type of catheter and presumably the type of perforation at the catheter tip may influence the incidence of peritoneal dialysis catheter obstruction. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Prevalence and Risk Factors of Central Venous Stenosis among Prevalent Hemodialysis Patients, a Single Center Experience.

    Science.gov (United States)

    Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra

    2014-01-01

    Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.

  4. Suprapubic cystostomy using optical urethrotome in female patients.

    Science.gov (United States)

    Sawant, Ajit Somaji; Patwardhan, Sujata K; Attar, Mohammad Ismail; Varma, Radheshyam; Bansal, Ujjwal

    2009-08-01

    In many female patients for lower urinary tract reconstructive procedures, a suprapubic cystostomy along with perurethral catheter is required for urinary diversion. We describe a new and simple method of intraoperative suprapubic catheter placement using optical urethrotome wherein distension of bladder is not required. A total of 26 patients underwent suprapubic catheter placement intraoperatively with the aid of Sachse' optical urethrotome and its outer sheath from January 2005 to May 2008. A 16F Foley catheter could be successfully placed suprapubically in all patients with this method. There were no complications like injury to intraabdominal viscera, retropubic hematoma, hematuria, or catheter dislodgement. We describe a new method of intraoperative suprapubic catheter placement in female patients that is minimally invasive, technically safe, simple, and effective, and does not require bladder distension.

  5. Something has shifted: Nursing students' global perspective following international clinical placements.

    Science.gov (United States)

    Gower, Shelley; Duggan, Ravani; Dantas, Jaya A R; Boldy, Duncan

    2017-10-01

    To examine understandings of global health issues among nursing students following participation in an international clinical placement during their pre-registration university education. Universities use international clinical placements, especially in developing countries, to develop cultural awareness in students; however, little is known about the longer term influences on students' understandings of global nursing. A retrospective cross-sectional design was used, using an exploratory, descriptive qualitative approach. Individual semi-structured interviews were conducted in 2014 with a purposive sample of 25 pre-registration nursing students from four Western Australian universities who undertook clinical placements across five countries. Data were analysed using inductive thematic analysis. Findings highlight that students developed new understandings around health systems including fragility of resource access, differences in clinical practice and variances in nursing roles between settings. Students also experienced challenges but were able to appreciate alternative world viewpoints. International clinical placements can develop greater awareness and help students form realistic strategies for using their nursing skills globally. Pre-placement training in cultural awareness and health system realities, along with strong supervisory support, is critical to success. © 2017 John Wiley & Sons Ltd.

  6. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    Science.gov (United States)

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  7. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...... cardiologists towards catheter ablation for AF, using a nationwide survey. METHODS AND RESULTS: We developed a purpose-designed questionnaire to evaluate attitudes towards catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between...... attitudes towards ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of 7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases...

  8. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  9. Detection of electrophysiology catheters in noisy fluoroscopy images.

    Science.gov (United States)

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  10. Role of echocardiography for catheter-based management of valvular heart disease.

    Science.gov (United States)

    Shiota, Takahiro

    2017-01-01

    Catheter-based treatment of valvular heart disease, such as transvalvular aortic valve replacement (TAVR) or mitral clip procedure, has been increasingly accepted as a treatment choice for the past several years. Such new treatment options have been changing the management of patients with valvular heart disease drastically while socio-economic factors regarding their application need to be taken into consideration. The use of echocardiography, including transesophageal echocardiography (TEE), for such catheter-based treatments is essential for the success of the procedures. Severe hypotension after TAVR is a life-threatening emergency. Rapid assessment and diagnosis in the catheterization or hybrid laboratory is essential for safety and a positive outcome. Possible diagnoses in this critical situation would include severe left ventricular dysfunction due to coronary obstruction, cardiac tamponade, aortic rupture, acute severe aortic and/or mitral valve regurgitation, and hypovolemia due to bleeding. Although new types of TAVR valves reduce para-valvular aortic regurgitation (AR) significantly, it is still important to judge the severity of para-valvular AR correctly in the laboratory. As for mitral clip procedure, TEE is vital for guiding and monitoring the entire process. Accurate identification of the location and the geometry of the regurgitant orifice is necessary for proper placement of the clip. Real-time 3D TEE provides helpful en face view of the mitral valve and clip together to this end. Residual mitral regurgitation (MR) after the first clip is not uncommon. Quick and precise imaging of the residual MR (location and severity) with TEE is extremely important for the interventionist to place the second clip and possibly third clip properly. After the completion of the clip procedure, mitral valve stenosis and also iatrogenic atrial septal defect need to be checked by TEE. Echocardiography, especially TEE, is also vital for the success of other newer trans-catheter

  11. Beware: The femoral haemodialysis catheter – a surgeon’s perspective

    Directory of Open Access Journals (Sweden)

    Tinus du Toit

    2017-06-01

    Full Text Available The ability to identify and address factors that threaten the optimal utilisation of donor organs is quintessential in obtaining satisfactory transplant outcomes. We share our concerns regarding the prolonged use of femoral haemodialysis catheters and its potential to jeopardise successful renal transplantation. Despite a paucity of literature on the topic, we review relevant aspects related to this pernicious form of vascular access and clarify its limited role in the modern haemodialysis unit, particularly in patients who are still considered for transplantation.

  12. Use of the 4F Roesch Inferior Mesenteric Catheter in Embolization Procedures in the Pelvis: A Review of 300 Cases

    International Nuclear Information System (INIS)

    Kroencke, Thomas J.; Kluner, Claudia; Hamm, Bernd; Gauruder-Burmester, Annett

    2007-01-01

    The aim of this study is to evaluate the use of a 4F Roesch inferior mesenteric (RIM) catheter for pelvic embolization procedures. Between October 2000 and January 2006, 364 patients (357 female, 7 male; age: 23-67 years) underwent embolization of various pathologies [uterine fibroids (n = 324), pure adenomyosis of the uterus (n = 19), postpartum hemorrhage (n =1), traumatic or postoperative hemorrhage (n = 9), bleeding related to cervical cancer (n =7), AV malformation of the uterus (n = 2) and high-flow priapism (n = 2)] at a single institution. In all cases, bilateral catheterization was primarily attempted with the use of a 4F hook-shaped braided endhole catheter (Roesch-Inferior-Mesenteric, RIM-Catheter, Cordis, Miami, FL). Frequency of initial failure to catheterize the vascular territory of interest and carry out the embolization were recorded and the types of difficulty encountered were noted. Catherization of the main stem of the vessel territory of interest with the use of a unilateral femoral approach and the 4F RIM catherer was successful in 334/364 (91.8%) the embolization cases. Bilateral catheterization of the internal iliac arteries using a single common femoral artery access and the 4F RIM catheter was achieved in 322/364 (88.5%) patients. In 12/364 (3.3%) patients, a contralateral puncture was performed and the same 4F catheter was used. In 28/364 (7.7%) cases the 4F RIM catheter was exchanged for a catheter with a cobra-shaped or sidewinder configuration. The 4F RIM catheter is a simple and valuable alternative to catheters and techniques commonly employed for pelvic artery embolization

  13. Systematic review and meta-analysis: reminder systems to reduce catheter-associated urinary tract infections and urinary catheter use in hospitalized patients.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Macy, Michelle; Saint, Sanjay

    2010-09-01

    Prolonged catheterization is the primary risk factor for catheter-associated urinary tract infection (CAUTI). Reminder systems are interventions used to prompt the removal of unnecessary urinary catheters. To summarize the effect of urinary catheter reminder systems on the rate of CAUTI, urinary catheter use, and the need for recatheterization, we performed a systematic review and meta-analysis. Studies were identified in MEDLINE, the Cochrane Library, Biosis, the Web of Science, EMBASE, and CINAHL through August 2008. Only interventional studies that used reminders to physicians or nurses that a urinary catheter was in use or stop orders to prompt catheter removal in hospitalized adults were included. A total of 6679 citations were identified; 118 articles were reviewed, and 14 articles met the selection criteria. The rate of CAUTI (episodes per 1000 catheter-days) was reduced by 52% (P SMD) in the duration of catheterization was -1.11 overall (P = 070), including a statistically significant decrease in studies that used a stop order (SMD, -0.30; P = .001) but not in those that used a reminder (SMD, -1.54; P = .071). Recatheterization rates were similar in control and intervention groups. Urinary catheter reminders and stop orders appear to reduce the rate of CAUTI and should be strongly considered to enhance the safety of hospitalized patients.

  14. Advanced Placement Environmental Science and the Curriculum and Community Enterprise for Restoration Science (CCERS) Project in the New York City High School

    Science.gov (United States)

    Birney, Lauren; McNamara, Denise

    2018-01-01

    This paper explores the issue of social justice through the lens of equitable access to Advanced Placement courses in the City of New York High Schools, with focus on Advanced Placement Environmental Science. A critical component of the Advanced Placement Environmental Science course is the incorporation of environmental fieldwork. The National…

  15. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner catheter to deliver stents for anomalous right coronary artery

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    2015-10-01

    Full Text Available Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  16. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... a catheter, x-ray imaging guidance and an injection of contrast material to examine blood vessels in ... technologies and, in most cases, a contrast material injection is needed to produce pictures of blood vessels ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... the American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available ... will regain their normal function within five to seven days. Rarely, the catheter punctures the artery, causing ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... Once the catheter is guided to the area being examined, a contrast material is injected through the ... You should inform your physician of any medications being taken and if there are any allergies, especially ...

  12. [The unnecessary application of central venous catheterization in surgical patients].

    Science.gov (United States)

    Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko

    2018-04-06

    Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on

  13. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    Science.gov (United States)

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  14. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  15. Radiologically-placed venous ports in children under venous anesthesia

    International Nuclear Information System (INIS)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak

    2015-01-01

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  16. Radiologically-placed venous ports in children under venous anesthesia

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak [Pusan National University School of Medicine, Yangsan (Korea, Republic of)

    2015-02-15

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  17. Iatrogenic Bowel Injury at Exchange of Supra-Pubic Catheter

    LENUS (Irish Health Repository)

    Foran, AT

    2018-04-01

    Suprapubic catheter insertion and exchange is a common urological procedure, but it is not without risks and complications. While bowel perforation is a recognised complication at suprapubic catheter insertion, it is not commonly reported at suprapubic catheter exchange. We report our experience of recognition, diagnosis and subsequent successful management of the most important complication related to suprapubic catheters.

  18. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  19. The bowed catheter sign: a risk for pericardial tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Richard [Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2008-03-15

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  20. The bowed catheter sign: a risk for pericardial tamponade

    International Nuclear Information System (INIS)

    Towbin, Richard

    2008-01-01

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  1. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    Science.gov (United States)

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  2. Catheter Associated Urinary Tract Infection Prevention bundle

    Directory of Open Access Journals (Sweden)

    O. Zarkotou

    2017-01-01

    Full Text Available Catheter-associated urinary tract infections (CAUTI are among the most common healthcare-associated infections, and potentially lead to significant morbidity and mortality. Multifaceted infection control strategies implemented as bundles can prevent nosocomial infections associated with invasive devices such as CAUTIs. The components of the CAUTI bundle proposed herein, include appropriate indications for catheterization and recommendations for the procedures of catheter insertion and catheter maintenance and care. Avoiding unnecessary urinary catheter use is the most effective measure for their prevention. To minimize the risk of CAUTI, urinary catheters should be placed only when a clinical valid indication is documented and they should be removed as soon as possible; alternatives to catheterization should also be considered. Aseptic insertion technique, maintenance of closed drainage system and strict adherence to hand hygiene are essential for preventing CAUTI. The successful implementation of the bundle requires education and training for all healthcare professionals and evaluation of surveillance data.

  3. Virtual-Reality Simulator System for Double Interventional Cardiac Catheterization Using Fractional-Order Vascular Access Tracker and Haptic Force Producer

    Directory of Open Access Journals (Sweden)

    Guan-Chun Chen

    2015-01-01

    Full Text Available This study proposes virtual-reality (VR simulator system for double interventional cardiac catheterization (ICC using fractional-order vascular access tracker and haptic force producer. An endoscope or a catheter for diagnosis and surgery of cardiovascular disease has been commonly used in minimally invasive surgery. It needs specific skills and experiences for young surgeons or postgraduate year (PGY students to operate a Berman catheter and a pigtail catheter in the inside of the human body and requires avoiding damaging vessels. To improve the training in inserting catheters, a double-catheter mechanism is designed for the ICC procedures. A fractional-order vascular access tracker is used to trace the senior surgeons’ consoled trajectories and transmit the frictional feedback and visual feedback during the insertion of catheters. Based on the clinical feeling through the aortic arch, vein into the ventricle, or tortuous blood vessels, haptic force producer is used to mock the elasticity of the vessel wall using voice coil motors (VCMs. The VR establishment with surgeons’ consoled vessel trajectories and hand feeling is achieved, and the experimental results show the effectiveness for the double ICC procedures.

  4. Central Venous Occlusion in the Hemodialysis Patient.

    Science.gov (United States)

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  6. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.

    Science.gov (United States)

    Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa

    2017-09-14

    To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.

  7. Can femoral dialysis catheter insertion cause a life threatening complication?

    Directory of Open Access Journals (Sweden)

    Nurkay Katrancıoğlu

    2014-09-01

    Full Text Available Venous catheter (VC insertion may be necessary for the patients with renal failure facing vascular access problem. Femoral VCs are commonly used for their lower complication rates especially in emergency clinics. The incidence of bleeding associated with VC is reported 0.5-1.6%, however, life threatening hemorrhage and complications requiring surgical intervention are very rare. In this manuscript, we aimed to present a case with hemolytic uremic syndrome complicated with retroperitoneal hematoma after femoral VC insertion. J Clin Exp Invest 2014; 5 (3: 472-474

  8. Cerebrospinal Fluid Leak at Percutaneous Exit of Ventricular Catheter as a Crucial Risk Factor for External Ventricular Drainage-Related Infection in Adult Neurosurgical Patients.

    Science.gov (United States)

    Park, Jaechan; Choi, Yeon-Ju; Ohk, Boram; Chang, Hyun-Ha

    2018-01-01

    The placement of a ventricular catheter for temporary cerebrospinal fluid (CSF) diversion is associated with a considerable risk of CSF infection. The authors investigated the effect of a CSF leak on CSF-related infection and the predisposing factors for a CSF leak. Fifty-two patients who underwent external ventricular drainage (EVD) for acute hydrocephalus associated with a subarachnoid hemorrhage or intraventricular hemorrhage (IVH) were enrolled in this prospective study. A CSF leak-detection paper (small sterilized filter paper) was applied at the percutaneous catheter exit site to check for any bloody CSF leak. In addition, radiologic and clinical data were collected. Four of the 52 patients (7.7%) developed an EVD-related CSF infection from organisms including Staphylococcus epidermidis (n = 3) and Staphylococcus hominis (n = 1). A prolonged CSF leak >1 day was detected in 9 patients (17.3%) and revealed as a significant risk factor for CSF infection with a 44.4% positive predictive value. Moreover, an IVH >10 mL was found in 11 patients (21.2%) and revealed as a significant predisposing factor for a CSF leak at the percutaneous catheter exit. A prolonged CSF leak for >1 day at the percutaneous catheter exit site is a crucial risk factor for EVD-related CSF infection and an IVH >10 mL is a predisposing factor for a CSF leak. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Urethral catheters: can we reduce use?

    NARCIS (Netherlands)

    Broek, P.J. van den; Wille, J.C.; Benthem, B.H.B. van; Perenboom, R.J.M.; Akker-van Marle, M.E. van den; Nielen, A.M.A.

    2011-01-01

    Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. The efficacy of an intervention programme to improve adherence to

  10. Bacterial Biofilms and Catheters: A Key to Understanding Bacterial Strategies in Catheter-Associated Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    J Curtis Nickel

    1992-01-01

    Full Text Available Despite major technological improvements in catheter drainage systems, the indwelling Foley catheter remains the most common cause of nosocomial infection in medical practice. By approaching this common complicated urinary tract infection from the perspective of the biofilm strategy bacteria appear to use to overcome obstacles to produce bacteriuria, one appreciates a new understanding of these infections. An adherent biofilm of bacteria in their secretory products ascends the luminal and external surface of the catheter and drainage system from a contaminated drainage spigot or urethral meatus into the bladder. If the intraluminal route of bacterial ascent is delayed by strict sterile closed drainage or addition of internal modifications to the system, the extraluminal or urethral route assumes greater importance in the development of bacteriuria, but takes significantly longer. Bacterial growth within these thick coherent biofilms confers a large measure of relative resistance to antibiotics even though the individual bacterium remains sensitive, thus accounting for the failure of antibiotic therapy. With disruption of the protective mucous layer of the bladder by mechanical irritation, the bacteria colonizing the catheter can adhere to the bladder’s mucosal surface and cause infection. An appreciation of the role of bacterial biofilms in these infections should suggest future directions for research that may ultimately reduce the risk of catheter-associated infection.

  11. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    Science.gov (United States)

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  12. Performance and safety of femoral central venous catheters in pediatric autologous peripheral blood stem cell collection.

    Science.gov (United States)

    Cooling, Laura; Hoffmann, Sandra; Webb, Dawn; Yamada, Chisa; Davenport, Robertson; Choi, Sung Won

    2017-12-01

    Autologous peripheral blood hematopoietic progenitor cell collection (A-HPCC) in children typically requires placement of a central venous catheter (CVC) for venous access. There is scant published data regarding the performance and safety of femoral CVCs in pediatric A-HPCC. Seven-year, retrospective study of A-HPCC in pediatric patients collected between 2009 and January 2017. Inclusion criteria were an age ≤ 21 years and A-HPCC using a femoral CVC for venous access. Femoral CVC performance was examined by CD34 collection rate, inlet rate, collection efficiency (MNC-FE, CD34-FE), bleeding, flow-related adverse events (AE), CVC removal, and product sterility testing. Statistical analysis and graphing were performed with commercial software. A total of 75/119 (63%) pediatric patients (median age 3 years) met study criteria. Only 16% of children required a CVC for ≥ 3 days. The CD34 collect rate and CD34-FE was stable over time whereas MNC-FE decreased after day 4 in 80% of patients. CD34-FE and MNC-FE showed inter- and intra-patient variability over time and appeared sensitive to plerixafor administration. Femoral CVC showed fewer flow-related AE compared to thoracic CVC, especially in pediatric patients (6.7% vs. 37%, P = 0.0005; OR = 0.12 (95%CI: 0.03-0.45). CVC removal was uneventful in 73/75 (97%) patients with hemostasis achieved after 20-30 min of pressure. In a 10-year period, there were no instances of product contamination associated with femoral CVC colonization. Femoral CVC are safe and effective for A-HPCC in young pediatric patients. Femoral CVC performance was maintained over several days with few flow-related alarms when compared to thoracic CVCs. © 2017 Wiley Periodicals, Inc.

  13. Types of urethral catheter for reducing symptomatic urinary tract infections in hospitalised adults requiring short-term catheterisation: multicentre randomised controlled trial and economic evaluation of antimicrobial- and antiseptic-impregnated urethral catheters (the CATHETER trial).

    Science.gov (United States)

    Pickard, R; Lam, T; Maclennan, G; Starr, K; Kilonzo, M; McPherson, G; Gillies, K; McDonald, A; Walton, K; Buckley, B; Glazener, C; Boachie, C; Burr, J; Norrie, J; Vale, L; Grant, A; N'dow, J

    2012-11-01

    Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital and incurs significant costs for health-care providers such as the UK NHS. Many preventative strategies and measures have been introduced to minimise CAUTI risk, including the use of antimicrobial catheters. However, there is considerable uncertainty regarding their usefulness in terms of reducing symptomatic CAUTI, and whether or not they are cost-effective. Do antimicrobial catheters reduce the rate of symptomatic urinary tract infection (UTI) during short-term hospital use and is their use cost-effective for the UK NHS? A pragmatic multicentre UK randomised controlled trial comparing three catheters as they would be used in the UK NHS: antimicrobial-impregnated (nitrofurazone) and antiseptic-coated (silver alloy) catheters with the standard polytetrafluoroethylene (PTFE)-coated catheters. Economic evaluation used a decision model populated with data from the trial. Sensitivity analysis was used to explore uncertainty. Relevant clinical departments in 24 NHS hospitals throughout the UK. Adults requiring temporary urethral catheterisation for a period of between 1 and 14 days as part of their care, predominantly as a result of elective surgery. Eligible participants were randomised 1 : 1 : 1 to one of three types of urethral catheter in order to make the following pragmatic comparisons: nitrofurazone-impregnated silicone catheter compared with standard PTFE-coated latex catheter; and silver alloy-coated hydrogel latex catheter compared with standard PTFE-coated latex catheter. The primary outcome for clinical effectiveness was the incidence of UTI at any time up to 6 weeks post randomisation. This was defined as any symptom reported during catheterisation, up to 3 days or 1 or 2 weeks post catheter removal or 6 weeks post randomisation combined with a prescription of antibiotics, at any of these times, for presumed symptomatic UTI. The primary economic

  14. Counterbalancing clinical supervision and independent practice: case studies in learning thoracic epidural catheter insertion.

    Science.gov (United States)

    Johnson, T

    2010-12-01

    Thoracic epidural catheter placement is an example of a demanding and high-risk clinical skill that junior anaesthetists need to learn by experience and under the supervision of consultants. This learning is known to present challenges that require further study. Ten consultant and 10 trainee anaesthetists in a teaching hospital were interviewed about teaching and learning this skill in the operating theatre, and a phenomenological analysis of their experience was performed. Trainee participation was limited by time pressure, lack of familiarity with consultants, and consultants' own need for clinical experience. There was a particular tension between safe and effective consultant practice and permitting trainees' independence. Three distinct stages of participation and assistance were identified from reports of ideal practice: early (part-task or basic procedure, consultant always present giving instruction and feedback), middle (independent practice with straightforward cases without further instruction), and late (skill extension and transfer). Learning assistance provided by consultants varied, but it was often not matched to the trainees' stages of learning. Negotiation of participation and assistance was recognized as being useful, but it did not happen routinely. There are many obstacles to trainees' participation in thoracic epidural catheter insertion, and learning assistance is not matched to need. A more explicit understanding of stages of learning is required to benefit the learning of this and other advanced clinical skills.

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... key areas of the body for abnormalities such as aneurysms and disease such as atherosclerosis (plaque). The use of a catheter makes ... including the: brain neck heart chest abdomen (such as the kidneys and liver) pelvis legs and feet ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  17. Management of Non- Deflating Foley Suprapubic Catheters - A ...

    African Journals Online (AJOL)

    The procedure described uses a 10 ml syringe and needle passed through the lumen of the catheter to puncture the inner surface of the catheter balloon and thus deflate it. Because the catheter balloon does not burst in this procedure there is no risk of balloon fragmentation or subsequent stone formation. The technique is ...

  18. Urethral catheters: can we reduce use?

    Directory of Open Access Journals (Sweden)

    van den Akker-van Marle M Elske

    2011-05-01

    Full Text Available Abstract Background Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. Methods The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. Results Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13 and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13, decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96, but increased significantly in intensive care (IC and coronary care (CC units (OR 1.48; 95% CI 1.01 - 2.17. The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16 and neurology (ratio 0.97; 95% CI 0.80 - 1.18 and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96 and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90. The percentage of correct indications on the day of inclusion increased from 50 to 67% (p Conclusion Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or

  19. An Evaluation of Complications in Ultrasound-Guided Central Venous Catheter Insertion in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Engin OZAKIN

    2014-06-01

    Full Text Available SUMMARY: Objectives: In emergency departments, emergency physicians frequently have to perform central venous access. In cases where peripheral venous access is not possible, central venous access is required for dialysis, fulfillment of urgent fluid need, or central venous pressure measurement. This study was carried out to evaluate the emergence of complications in the process of and in the 15 days following the insertion of central venous catheter under ultrasound guidance in the emergency department. Methods: For this study, patients who presented to the emergency department over a period of eight months with an urgent need for central catheter were examined prospectively. Age, gender, and accompanying diseases of patients as well as the type, time, duration, and indication of the venous access were recorded. Furthermore, the amount of experience of the physician was taken into consideration. Results: In the emergency department, physicians performed ultrasound-guided central venous catheter insertion for 74 patients (40 men and 34 women. For access, internal jugular vein was used in 65 (87.8% patients, and femoral vein was used in 9 (12.2% patients. The reason for access was urgent dialysis need in 55 (74.3%, CVP measurement in 3 (4.1%, fluid support due to severe hypovolemia in 6 (8.1%, and difficulty of peripheral venous access in 10 (13.5% patients. None of the patients developed complications in the process of or after the insertion. Patients did not have infections related to the catheter in 15 days following the insertion. Conclusions: Central venous access is frequently required in emergency departments. The risk of complication is little if any in ultrasonographyguided access carried out under appropriate conditions. ÖZET: Amaç: Acil servislerde acil tıp hekimlerince santral damar yolu işlemi sık uygulanır. Periferik damar yolu açılamadığı hallerde, diyaliz, acil sıvı ihtiyacı veya santral venöz basınç

  20. 21 CFR 880.5200 - Intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  1. Intra-Arterial Hepatic Chemotherapy: A Comparison of Percutaneous Versus Surgical Implantation of Port-Catheters

    International Nuclear Information System (INIS)

    Deschamps, F.; Elias, D.; Goere, D.; Malka, D.; Ducreux, M.; Boige, V.; Auperin, A.; Baere, T. de

    2011-01-01

    Purpose: To compare retrospectively the safety and efficacy of percutaneous and surgical implantations of port-catheters for intra-arterial hepatic chemotherapy (IAHC). Materials and Methods: Between January 2004 and December 2008, 126 consecutive patients (mean age 58 years) suffering from liver colorectal metastases were referred for intra-arterial hepatic chemotherapy (IAHC). Port-catheters were percutaneously implanted (P) through femoral access with the patient under conscious sedation when no other surgery was planned or were surgically implanted (S) when laparotomy was performed for another purpose. We report the implantation success rate, primary functionality, functionality after revision, and complications of IAHC. Results: The success rates of implantation were 97% (n = 65 of 67) for P and 98% (n = 58 of 59) for S. One hundred eleven patients received IAHC in our institution (n = 56P and n = 55S). Primary functionality was the same for P and S (4.80 vs. 4.82 courses), but functionality after revision was significantly higher for P (9.18 vs. 5.95 courses, p = 0.004) than for S. Forty-five complications occurred during 516 courses for P and 28 complications occurred during 331 courses for S. The rates of discontinuation of IAHC linked to complications of the port-catheters were 21% (n = 12 of 56) for P and 34% (n = 19 of 55) for S. Conclusion: Overall, significantly better functionality and similar complication rates occurred after P versus S port-catheters.

  2. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-04-01

    Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, pSMD) in catheterisation duration (days) was -1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD -0.37; pSMD, -1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits.

  3. Health professional students' rural placement satisfaction and rural practice intentions: A national cross-sectional survey.

    Science.gov (United States)

    Smith, Tony; Sutton, Keith; Pit, Sabrina; Muyambi, Kuda; Terry, Daniel; Farthing, Annie; Courtney, Claire; Cross, Merylin

    2018-02-01

    The aim of this study was to profile students undertaking placements at University Departments of Rural Health (UDRHs) and investigate factors affecting students' satisfaction and intention to enter rural practice. Cross-sectional survey comprising 21 core questions used by all UDRHs. Eleven UDRHs across Australia that support students' placements in regional, rural and remote locations. Medical, nursing and allied health students who participated in UDRH placements between July 2014 and November 2015 and completed the questionnaire. Key dependent variables were placement satisfaction and rural practice intention. Descriptive variables were age, gender, Aboriginal or Torres Strait Islander (ATSI) background, location of placement, healthcare discipline, year of study and type and length of placement. A total of 3328 students responded. The sample was predominantly female (79%), the mean age was 26.0 years and 1.8% identified as ATSI. Most placements (69%) were >2 but ≤12 weeks, 80% were in Modified Monash 3, 4 or 5 geographical locations. Public hospitals and community health made up 63% of placements. Students satisfied with their placement had 2.33 higher odds of rural practice intention. Those satisfied with Indigenous cultural training, workplace supervision, access to education resources and accommodation had higher odds of overall satisfaction and post-placement rural practice intention. The majority of students were highly satisfied with their placement and the support provided by rural clinicians and the UDRHs. UDRHs are well placed to provide health professional students with highly satisfactory placements that foster rural practice intention. © 2017 National Rural Health Alliance Inc.

  4. Local Intravascular Drug Delivery: In Vitro Comparison of Three Catheter Systems

    International Nuclear Information System (INIS)

    Alfke, Heiko; Wagner, Hans-Joachim; Calmer, Christian; Klose, Klaus Jochen

    1998-01-01

    Purpose: The aim of this in vitro study was to compare different catheter systems for local drug delivery with respect to the penetration depth of a biotin marker solution delivered into the vessel wall. Methods: Post-mortem carotid arteries from pigs were locally infused with a biotin solution using three different catheter systems. With all catheters (microporous balloon catheter, hydrogel-coated balloon catheter, and spiral balloon catheter) we used the same pressure of 405 kPa (4 atm) and infusion times of 60, 90, and 300 sec. After infusion the arteries were histologically prepared and stained using a biotin-specific method. With a light microscope an observer, blinded to the catheter type, scored the amount of biotin within the vessel wall, measured as staining intensity, and the penetration depth of the biotin. Results: Delivery with the hydrogel-coated balloon catheter was limited to the intima and the innermost parts of the media. The spiral balloon and microporous balloon catheter showed both a deeper penetration and a larger amount of delivered biotin compared with the hydrogel catheter, with a slightly deeper penetration using the microporous catheter. The penetration depth showed a correlation with infusion time for the spiral balloon and microporous catheters, but not for the hydrogel-coated catheter. Conclusion: Different catheter designs lead to different patterns of local drug delivery. The differences in penetration depth and amount of the substance delivered to the vessel wall should be known and might be useful for targeting specific areas within the vessel wall

  5. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67......) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC...

  6. Miniaturization of catheter systems for angiography

    International Nuclear Information System (INIS)

    Hawkins, I.F. Jr.; Akins, E.W.

    1988-01-01

    The authors discuss the use of small catheters and needles in angiography and interventional procedures to improve the quality of the procedures and increase the success rate and safety. This philosophy was initially poorly received, both by operators and by industry; however, more recently microtechniques have become more acceptable primarily because of the changing economic climate requiring procedures with shorter or no hospitalization time. Since 1970, the authors have performed well over 10,000 angiographic procedures using 5 French catheters, or smaller. During the last 12 years, they have used almost exclusively 4 French catheters, primarily with standard filming techniques which have resulted in no thrombosed arteries, or significant hematoma formation

  7. Cryoballoon Catheter Ablation in Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Cevher Ozcan

    2011-01-01

    Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.

  8. [Prevention of catheter-related infection: usefulness and cost-effectiveness of antiseptic catheters in children].

    Science.gov (United States)

    Lenz, Ana M; Vassallo, Juan C; Moreno, Guillermo E; Althabe, María; Gómez, Silvia; Magliola, Ricardo; Casimir, Lidia; Bologna, Rosa; Barretta, Jorge; Ruffa, Pablo

    2010-06-01

    To evaluate the cost-effectiveness of the antiseptic-impregnated catheter compared with conventional catheters in preventing catheter- related blood stream infections (CR-BSI). Cost-effectiveness analysis; clinical trial, experimental, randomized, controlled, prospective, open label. Patients and methods. A 172 patient cohort, under 1-year-old or less than 10 kg, postoperative cardiovascular children with central venous catheters (CVC) admitted to Cardiac Intensive Care Unit (UCI 35) at Hospital Nacional de Pediatría "Prof. Dr. Juan P. Garrahan", since September 2005 to December 2007. Demographic and CVC data were retrieved to compare: age, gender, weight, diagnosis, surgery, CVC days, costs and complications. Intervention. CVC Arrow, double-lumen, > 48 h of duration; intervention group: antiseptic-impregnated CVC vs. control group: CVC without antiseptics (conventional). The incidence of CR-IE (CR-Infected Events: colonization, local infection and/or CRBSI; combined end point) was 27% for antiseptic- impregnated CVC vs. 31% for conventional catheters (p= 0.6) with similar accumulated incidence of CR- BSI: 2.8 vs. 3.3 per 1000 dayscatheter. We found no differences between groups, except in weight: median 4.0 kg (r 2-17) vs. 4.7 kg (r 2-9) p= 0.0002 and age, median 2 months (r 1- 48) vs. 5 months (r 1- 24) p= 0.0019 in antiseptic-impregnated CVC group. These differences, though statistically significant were clinically non relevant. Median cost per patient during intensive care stay in the conventional CVC group was $3.417 (359-9.453) and in the antiseptic-impregnated-CVC group was $4.962 (239-24.532), p= 0.10. The use of antiseptic-impregnated CVC compared with conventional CVC did not decrease CR-BSI in this population. The cost per patients was higher in the antiseptic impregnated CVC group. These results do not support the routine use of this type of CVC in our population.

  9. Human factors related to time-dependent infection control measures: "Scrub the hub" for venous catheters and feeding tubes.

    Science.gov (United States)

    Caspari, Lindsay; Epstein, Elizabeth; Blackman, Amy; Jin, Li; Kaufman, David A

    2017-06-01

    The use of catheter hub decontamination protocols is a common practice to reduce central line-associated bloodstream infections. However, few data exist on the most effective disinfection procedure prior to hub access accounting for human factors and time-dependent practices in real time in the clinical setting. An observational design with a multimodal intervention was used in this study in a neonatal intensive care unit. Direct observations on nurse compliance of scrub times with decontamination when accessing of venous catheter and feeding tube hubs were conducted during 3 phases: (1) baseline period prior to any interventions; (2) during an educational intervention phase; and (3) during a timer intervention period when using a timing device, either an actual timer or music button. Overall, both education and the timing device interventions increased the mean scrub time ± SD of venous catheter hubs. Mean baseline scrub times of 10 ± 5 seconds were lower compared with 23 ± 12 seconds after educational intervention (P music button use (P observed with scrub times of feeding tubes. Time-based infection control measures, such as scrubbing the hub, must be implemented with aids that qualify specific times to account for human factors, to ensure adherence to time-dependent measures aimed at decreasing nosocomial infections. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  11. Change in Vascular Access and Hospitalization Risk in Long-Term Hemodialysis Patients

    Science.gov (United States)

    Wang, Weiling; Lazarus, J. Michael; Hakim, Raymond M.

    2010-01-01

    Background and objectives: Conversion from central venous catheters to a graft or a fistula is associated with lower mortality risk in long-term hemodialysis (HD) patients; however, a similar association with hospitalization risk remains to be elucidated. Design, setting, participants, & measurements: We conducted a prospective observational study all maintenance in-center HD patients who were treated in Fresenius Medical Care, North America legacy facilities; were alive on January 1, 2007; and had baseline laboratory data from December 2006. Access conversion (particularly from a catheter to a fistula or a graft) during the 4-month period from January 1 through April 30, 2007, was linked using Cox models to hospitalization risk during the succeeding 1-year follow-up period (until April 30, 2008). Results: The cohort (N = 79,545) on January 1, 2007 had 43% fistulas, 29% catheters, and 27% grafts. By April 30, 2007, 70,852 patients were still on HD, and among 19,792 catheters initially, only 10.3% (2045 patients) converted to either a graft or a fistula. With catheters as reference, patients who converted to grafts/fistulas had similar adjusted hazard ratios (0.69) as patients on fistulas (0.71), while patients with fistulas/grafts who converted to catheters did worse (1.22), all P < 0.0001. Conclusions: Catheters remain associated with the greatest hospitalization risk. Conversion from a catheter to either graft or fistula had significantly lower hospitalization risk relative to keeping the catheter. Prospective studies are needed to determine whether programs that reduce catheters will decrease hospitalization risk in HD patients. PMID:20884778

  12. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  13. Where does the pulmonary artery catheter float: Transesophageal echocardiography evaluation

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2015-01-01

    Full Text Available Background: Pulmonary artery (PA catheter provides a variety of cardiac and hemodynamic parameters. In majority of the patients, the catheter tends to float in the right pulmonary artery (RPA than the left pulmonary artery (LPA. We evaluated the location of PA catheter with the help of transesophageal echocardiography (TEE to know the incidence of its localization. Three views were utilized for this purpose; midesophageal ascending aorta (AA short-axis view, modified mid esophageal aortic valve long-axis view, and modified bicaval view. Methods: We enrolled 135 patients undergoing elective cardiac surgery where both the PA catheter and TEE were to be used; for this prospective observational study. PA catheter was visualized by TEE in the above mentioned views and the degree of clarity of visualization by three views was also noted. Position of the PA catheter was further confirmed by a postoperative chest radiograph. Results: One patient was excluded from the data analysis. PA catheter was visualized in RPA in 129 patients (96% and in LPA in 4 patients (3%. In 1 patient, the catheter was visualized in main PA in the chest radiograph. The midesophageal AA short-axis, modified aortic valve long-axis, and modified bicaval view provided good visualization in 51.45%, 57.4%, and 62.3% patients respectively. Taken together, PA catheter visualization was good in 128 (95.5% patients. Conclusion: We conclude that the PA catheter has a high probability of entering the RPA as compared to LPA (96% vs. 3% and TEE provides good visualization of the catheter in RPA.

  14. Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients

    International Nuclear Information System (INIS)

    Goltz, Jan P.; Scholl, Anne; Ritter, Christian O.; Wittenberg, Guenther; Hahn, Dietbert; Kickuth, Ralph

    2010-01-01

    The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days were analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.

  15. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    Science.gov (United States)

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  16. Magnetic catheter manipulation in the interventional MR imaging environment.

    Science.gov (United States)

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  17. Maintenance of peripheral venous access and its impact on the development of phlebitis: a survey of 186 catheters in a general surgery department in Portugal.

    Science.gov (United States)

    do Rego Furtado, Luís Carlos

    2011-01-01

    This article reports the results of a clinical audit conducted to assess the minimum requirements for safe maintenance of peripheral intravenous catheters. The audit also determined the incidence of phlebitis and attempted to establish a causal relationship between some of the variables used to assess a catheter's maintenance status and the development of phlebitis.

  18. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  19. The importance of effective catheter securement.

    Science.gov (United States)

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  20. Efficacy of a one-catheter concept for transradial coronary angiography.

    Directory of Open Access Journals (Sweden)

    Christoph Langer

    Full Text Available Transradial coronary angiography (TRC can be performed with a one-catheter approach for the right and left coronary ostium (R/LCO. We investigated the performance of a special diagnostic catheter widely used for the one-catheter-approach, the Tiger (Tiger II, TerumoTM.In a dual center registry we analyzed 1412 TRC-procedures exclusively performed by experienced TRC-operators. We compared the performance of the Tiger with Judkins catheters by retrospectively judging ostial catheter stability during contrast injection, and by measuring contrast use, fluoroscopy time (FT and complication rate.Poor or failed ostial engagement was found in 40.5% in the Tiger group, compared to 46.6% with the use of Judkins catheters (p<0.183. Ostial instability of the Tiger was found more often during engagement of the LCO than the RCO (34.4% vs. 10.8%, p<0.001, whereas it was similar in the LCO and RCO for Judkins catheters (27.4% vs. 26.7%, p = 0.840. TRC-procedures performed with Tiger catheters were associated with less contrast volume (63.48 ± 29.83mL vs. 82.51 ± 56.58mL, p<0.004 and shorter FT than with Judkins catheters. (198.27 ± 194.8sec vs. 326.85 ± 329.70sec. Forearm hematomas occurred less often with the Tiger (1.2% vs. 6.6%, p< 0.02.The Tiger employed as a single catheter in TRC is an effective tool to achieve lower contrast volume and fluoroscopy time at a low complication rate. Unstable engagement affects predominantly the left coronary artery, but its overall frequency is similar for both, the Tiger and Judkins catheters.