WorldWideScience

Sample records for acceptable test-retest reliability

  1. Test-retest reliability of cognitive EEG

    Science.gov (United States)

    McEvoy, L. K.; Smith, M. E.; Gevins, A.

    2000-01-01

    OBJECTIVE: Task-related EEG is sensitive to changes in cognitive state produced by increased task difficulty and by transient impairment. If task-related EEG has high test-retest reliability, it could be used as part of a clinical test to assess changes in cognitive function. The aim of this study was to determine the reliability of the EEG recorded during the performance of a working memory (WM) task and a psychomotor vigilance task (PVT). METHODS: EEG was recorded while subjects rested quietly and while they performed the tasks. Within session (test-retest interval of approximately 1 h) and between session (test-retest interval of approximately 7 days) reliability was calculated for four EEG components: frontal midline theta at Fz, posterior theta at Pz, and slow and fast alpha at Pz. RESULTS: Task-related EEG was highly reliable within and between sessions (r0.9 for all components in WM task, and r0.8 for all components in the PVT). Resting EEG also showed high reliability, although the magnitude of the correlation was somewhat smaller than that of the task-related EEG (r0.7 for all 4 components). CONCLUSIONS: These results suggest that under appropriate conditions, task-related EEG has sufficient retest reliability for use in assessing clinical changes in cognitive status.

  2. The Comprehensive Snack Parenting Questionnaire (CSPQ: Development and Test-Retest Reliability

    Directory of Open Access Journals (Sweden)

    Dorus W. M. Gevers

    2018-04-01

    Full Text Available The narrow focus of existing food parenting instruments led us to develop a food parenting practices instrument measuring the full range of food practices constructs with a focus on snacking behavior. We present the development of the questionnaire and our research on the test-retest reliability. The developed Comprehensive Snack Parenting Questionnaire (CSPQ covers 21 constructs. Test-retest reliability was assessed by calculating intra class correlation coefficients and percentage agreement after two administrations of the CSPQ among a sample of 66 Dutch parents. Test-retest reliability analysis revealed acceptable intra class correlation coefficients (≥0.41 or agreement scores (≥0.60 for all items. These results, together with earlier work, suggest sufficient psychometric characteristics. The comprehensive, but brief CSPQ opens up chances for highly essential but unstudied research questions to understand and predict children’s snack intake. Example applications include studying the interactional nature of food parenting practices or interactions of food parenting with general parenting or child characteristics.

  3. Test-retest reliability of jump execution variables using mechanography: a comparison of jump protocols.

    Science.gov (United States)

    Fitzgerald, John S; Johnson, LuAnn; Tomkinson, Grant; Stein, Jesse; Roemmich, James N

    2018-05-01

    Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73-0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.

  4. Test-retest reliability of a balance testing protocol with external perturbations in young healthy adults.

    Science.gov (United States)

    Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy

    2017-10-01

    External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICCbalance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Test-retest reliability of the Work Ability Index questionnaire

    NARCIS (Netherlands)

    de Zwart, B. C. H.; Frings-Dresen, M. H. W.; Van Duivenbooden, J. C.

    2002-01-01

    The goal of the study was to assess the test-retest reliability of the Work Ability Index (WAI) questionnaire. Reliability was tested using a test-retest design with a 4 week interval between measurements. Valid data were collected among 97 elderly construction workers aged 40 years and older. We

  7. Test-retest reliability of infant event related potentials evoked by faces.

    Science.gov (United States)

    Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C

    2017-04-05

    Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Test-retest reliability of the multifocal photopic negative response.

    Science.gov (United States)

    Van Alstine, Anthony W; Viswanathan, Suresh

    2017-02-01

    To assess the test-retest reliability of the multifocal photopic negative response (mfPhNR) of normal human subjects. Multifocal electroretinograms were recorded from one eye of 61 healthy adult subjects on two separate days using a Visual Evoked Response Imaging System software version 4.3 (EDI, San Mateo, California). The visual stimulus delivered on a 75-Hz monitor consisted of seven equal-sized hexagons each subtending 12° of visual angle. The m-step exponent was 9, and the m-sequence was slowed to include at least 30 blank frames after each flash. Only the first slice of the first-order kernel was analyzed. The mfPhNR amplitude was measured at a fixed time in the trough from baseline (BT) as well as at the same fixed time in the trough from the preceding b-wave peak (PT). Additionally, we also analyzed BT normalized either to PT (BT/PT) or to the b-wave amplitude (BT/b-wave). The relative reliability of test-retest differences for each test location was estimated by the Wilcoxon matched-pair signed-rank test and intraclass correlation coefficients (ICC). Absolute test-retest reliability was estimated by Bland-Altman analysis. The test-retest amplitude differences for neither of the two measurement techniques were statistically significant as determined by Wilcoxon matched-pair signed-rank test. PT measurements showed greater ICC values than BT amplitude measurements for all test locations. For each measurement technique, the ICC value of the macular response was greater than that of the surrounding locations. The mean test-retest difference was close to zero for both techniques at each of the test locations, and while the coefficient of reliability (COR-1.96 times the standard deviation of the test-retest difference) was comparable for the two techniques at each test location when expressed in nanovolts, the %COR (COR normalized to the mean test and retest amplitudes) was superior for PT than BT measurements. The ICC and COR were comparable for the BT/PT and

  9. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    Science.gov (United States)

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  10. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    Science.gov (United States)

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  11. Reliability of Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory in a test-retest design.

    Science.gov (United States)

    Larson, Tomas; Kerekes, Nóra; Selinus, Eva Norén; Lichtenstein, Paul; Gumpert, Clara Hellner; Anckarsäter, Henrik; Nilsson, Thomas; Lundström, Sebastian

    2014-02-01

    The Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A-TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A-TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's kappa. A-TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A-TAC had intra- and inter-rater reliability intraclass correlation coefficients of > or = .60. Cohen's kappa indi- cated acceptable reliability. The current study provides statistical evidence that the A-TAC yields good test-retest reliability in a population-based cohort of children.

  12. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  13. Test-retest reliability and predictive validity of the Implicit Association Test in children.

    Science.gov (United States)

    Rae, James R; Olson, Kristina R

    2018-02-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many factors simultaneously (lag-time between testing administrations, domain, etc.), it is difficult to discern what factors may explain variability in existing test-retest reliability and predictive validity estimates. Across five studies (total N = 519; ages 6- to 11-years-old), we manipulated two factors that have varied in previous developmental research-lag-time and domain. An internal meta-analysis of these studies revealed that, across three different methods of analyzing the data, mean test-retest (rs of .48, .38, and .34) and predictive validity (rs of .46, .20, and .10) effect sizes were significantly greater than zero. While lag-time did not moderate the magnitude of test-retest coefficients, whether we observed domain differences in test-retest reliability and predictive validity estimates was contingent on other factors, such as how we scored the IAT or whether we included estimates from a unique sample (i.e., a sample containing gender typical and gender diverse children). Recommendations are made for developmental researchers that utilize the IAT in their research. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  14. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  15. Test re-test reliability and construct validity of the star-track test of manual dexterity

    DEFF Research Database (Denmark)

    Kildebro, Niels; Amirian, Ilda; Gögenur, Ismail

    2015-01-01

    Objectives. We wished to determine test re-test reliability and construct validity of the star-track test of manual dexterity. Design. Test re-test reliability was examined in a controlled study. Construct validity was tested in a blinded randomized crossover study. Setting. The study was performed...... at a university hospital in Denmark. Participants. A total of 11 subjects for test re-test and 20 subjects for the construct validity study were included. All subjects were healthy volunteers. Intervention. The test re-test trial had two measurements with 2 days pause in between. The interventions...... in the construct validity study included baseline measurement, intervention 1: fatigue, intervention 2: stress, and intervention 3: fatigue and stress. There was a 2 day pause between each intervention. Main outcome measure. An integrated measure of completion time and number of errors was used. Results. All...

  16. Test-Retest Reliability and Minimal Detectable Change of the D2 Test of Attention in Patients with Schizophrenia.

    Science.gov (United States)

    Lee, Posen; Lu, Wen-Shian; Liu, Chin-Hsuan; Lin, Hung-Yu; Hsieh, Ching-Lin

    2017-12-08

    The d2 Test of Attention (D2) is a commonly used measure of selective attention for patients with schizophrenia. However, its test-retest reliability and minimal detectable change (MDC) are unknown in patients with schizophrenia, limiting its utility in both clinical and research settings. The aim of the present study was to examine the test-retest reliability and MDC of the D2 in patients with schizophrenia. A rater administered the D2 on 108 patients with schizophrenia twice at a 1-month interval. Test-retest reliability was determined through the calculation of the intra-class correlation coefficient (ICC). We also carried out Bland-Altman analysis, which included a scatter plot of the differences between test and retest against their mean. Systematic biases were evaluated by use of a paired t-test. The ICCs for the D2 ranged from 0.78 to 0.94. The MDCs (MDC%) of the seven subscores were 102.3 (29.7), 19.4 (85.0), 7.2 (94.6), 21.0 (69.0), 104.0 (33.1), 105.0 (35.8), and 7.8 (47.8), which represented limited-to-acceptable random measurement error. Trends in the Bland-Altman plots of the omissions (E1), commissions (E2), and errors (E) were noted, presenting that the data had heteroscedasticity. According to the results, the D2 had good test-retest reliability, especially in the scores of TN, TN-E, and CP. For the further research, finding a way to improve the administration procedure to reduce random measurement error would be important for the E1, E2, E, and FR subscores. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  18. The test-retest reliability and criterion validity of a high-intensity, netball-specific circuit test: The Net-Test.

    Science.gov (United States)

    Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T

    2018-04-12

    To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (Test possessed low CV and significant (pTest possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  19. Test-retest and interrater reliability of the functional lower extremity evaluation.

    Science.gov (United States)

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  20. Test-retest reliability of the proposed DSM-5 eating disorder diagnostic criteria

    Science.gov (United States)

    Sysko, Robyn; Roberto, Christina A.; Barnes, Rachel D.; Grilo, Carlos M.; Attia, Evelyn; Walsh, B. Timothy

    2012-01-01

    The proposed DSM-5 classification scheme for eating disorders includes both major and minor changes to the existing DSM-IV diagnostic criteria. It is not known what effect these modifications will have on the ability to make reliable diagnoses. Two studies were conducted to evaluate the short-term test-retest reliability of the proposed DSM-5 eating disorder diagnoses: anorexia nervosa, bulimia nervosa, binge eating disorder, and feeding and eating conditions not elsewhere classified. Participants completed two independent telephone interviews with research assessors (n=70 Study 1; n=55 Study 2). Fair to substantial agreements (κ= 0.80 and 0.54) were observed across eating disorder diagnoses in Study 1 and Study 2, respectively. Acceptable rates of agreement were identified for the individual eating disorder diagnoses, including DSM-5 anorexia nervosa (κ’s of 0.81 to 0.97), bulimia nervosa (κ=0.84), binge eating disorder (κ’s of 0.75 and 0.61), and feeding and eating disorders not elsewhere classified (κ’s of 0.70 and 0.46). Further, improved short-term test-retest reliability was noted when using the DSM-5, in comparison to DSM-IV, criteria for binge eating disorder. Thus, these studies found that trained interviewers can reliably diagnose eating disorders using the proposed DSM-5 criteria; however, additional data from general practice settings and community samples are needed. PMID:22401974

  1. Acoustic stapedial reflexes in healthy neonates: normative data and test-retest reliability.

    Science.gov (United States)

    Kei, Joseph

    2012-01-01

    The acoustic stapedial reflex (ASR) test provides useful information about the function of the auditory system. While it is frequently used with adults and children in a clinical setting, its use with young infants is limited. Presently, there are few data for neonates and inadequate research into the test-retest reliability of the ASR test. This study aimed to establish normative data and evaluate the test-retest reliability of the ASR test in healthy neonates. A cross-sectional experimental design was used to establish ASR normative data and assess the test-retest reliability of ASR thresholds obtained from healthy neonates. Sixty-eight full-term neonates with mean chronological age of 2.5 days (SD = 1.8 day), who passed the automated auditory brainstem response, transient evoked otoacoustic emission, and high frequency (1 kHz) tympanometry (HFT) tests. One randomly selected ear from each neonate was tested using TEOAE (transient evoked otoacoustic emission), HFT, and ASR tests using a 1 kHz probe tone. ASR thresholds were elicited by presenting pure tones of 0.5, 2, and 4 kHz and broadband noise (BBN) separately to the test ear in an ipsilateral stimulation mode. The ASR procedure was repeated to acquire retest data within the same testing session. Descriptive statistics, χ2, and analysis of variance with repeated measures tests were used to analyze ASR data. All neonates exhibited ASR when stimulated by tonal stimuli or BBN. The mean ASRTs (acoustic stapedial reflex thresholds) for the 0.5, 2, and 4 kHz tones were 81.6 ± 7.9, 71.3 ± 7.9, and 65.4 ± 8.7 dB HL, respectively. The mean ASRT for the BBN was estimated to be smaller than 57.2 dB HL, given the limitation of the equipment. The 95th percentiles of the ASRT were 95, 85, 80, and 75 dB HL for the 0.5, 2, and 4 kHz and BBN, respectively. The test-retest reliability of the ASR test for all stimuli was high, with no significant difference in mean ASRTs across the test and retest conditions. Test-retest

  2. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Test-retest reliability for aerodynamic measures of voice.

    Science.gov (United States)

    Awan, Shaheen N; Novaleski, Carolyn K; Yingling, Julie R

    2013-11-01

    The purpose of this study was to investigate the intrasubject reliability of aerodynamic characteristics of the voice within typical/normal speakers across testing sessions using the Phonatory Aerodynamic System (PAS 6600; KayPENTAX, Montvale, NJ). Participants were 60 healthy young adults (30 males and 30 females) between the ages 18 and 31 years with perceptually typical voice. Participants were tested using the PAS 6600 (Phonatory Aerodynamic System) on two separate days with approximately 1 week between each session at approximately the same time of day. Four PAS protocols were conducted (vital capacity, maximum sustained phonation, comfortable sustained phonation, and voicing efficiency) and measures of expiratory volume, maximum phonation time, mean expiratory airflow (during vowel production) and target airflow (obtained via syllable repetition), peak air pressure, aerodynamic power, aerodynamic resistance, and aerodynamic efficiency were obtained during each testing session. Associated acoustic measures of vocal intensity and frequency were also collected. All phonations were elicited at comfortable pitch and loudness. All aerodynamic and associated variables evaluated in this study showed useable test-retest reliability (ie, intraclass correlation coefficients [ICCs] ≥ 0.60). A high degree of mean test-retest reliability was found across all subjects for aerodynamic and associated acoustic measurements of vital capacity, maximum sustained phonation, glottal resistance, and vocal intensity (all with ICCs > 0.75). Although strong ICCs were observed for measures of glottal power and mean expiratory airflow in males, weaker overall results for these measures (ICC range: 0.60-0.67) were observed in females subjects and sizable coefficients of variation were observed for measures of power, resistance, and efficiency in both men and women. Differences in degree of reliability from measure to measure were revealed in greater detail using methods such as ICCs and

  4. Test-Retest Reliability of a Survey to Measure Transport-Related Physical Activity in Adults

    Science.gov (United States)

    Badland, Hannah; Schofield, Grant

    2006-01-01

    The present research details test-retest reliability of a newly developed, telephone-administered TPA survey for adults. This instrument examines barriers, perceptions, and current travel behaviors to place of work/study and local convenience shops. Demonstrated test-retest reliability of the Active Friendly Environments-Transport-Related Physical…

  5. Test-Retest Reliability and Predictive Validity of the Implicit Association Test in Children

    Science.gov (United States)

    Rae, James R.; Olson, Kristina R.

    2018-01-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many…

  6. Test-Retest Reliability of Computerized, Everyday Memory Measures and Traditional Memory Tests.

    Science.gov (United States)

    Youngjohn, James R.; And Others

    Test-retest reliabilities and practice effect magnitudes were considered for nine computer-simulated tasks of everyday cognition and five traditional neuropsychological tests. The nine simulated everyday memory tests were from the Memory Assessment Clinic battery as follows: (1) simple reaction time while driving; (2) divided attention (driving…

  7. Test-retest reliability of trunk accelerometric gait analysis

    DEFF Research Database (Denmark)

    Henriksen, Marius; Lund, Hans; Moe-Nilssen, R

    2004-01-01

    The purpose of this study was to determine the test-retest reliability of a trunk accelerometric gait analysis in healthy subjects. Accelerations were measured during walking using a triaxial accelerometer mounted on the lumbar spine of the subjects. Six men and 14 women (mean age 35.2; range 18...... a definite potential in clinical gait analysis....

  8. Long term test-retest reliability of Oswestry Disability Index in male office workers.

    Science.gov (United States)

    Irmak, Rafet; Baltaci, Gul; Ergun, Nevin

    2015-01-01

    The Oswestry Disability Index (ODI) is one of the most common condition specific outcome measures used in the management of spinal disorders. But there is insufficient study on healthy populations and long term test-retest reliability. This is important because healthy populations are often used for control groups in low back pain interventions, and knowing the reliability of the controls affects the interpretation of the findings of these studies. The purpose of this study is to determine the long term test-retest reliability of ODI in office workers. Participants who have no chronic low back pain history were included in study. Subjects were assessed by the Turkish-ODI 2.0 (e-forms) on 1st, 2nd, 4th, 8th, 15th, 30th days to determine the stability of ODI scores over time. The study began with 58 (12 female, 46 male) participants. 36 (3 female, 33 male) participated for the full 30 days. Kolmogorov-Smirnov and Friedman tests were used. Test-retest reliability was evaluated by using nonparametric statistics. All tests were done by using SPSS-11. There was no statistically significant difference among the median scores of each day. (χ= 6.482, p >  0.05). The difference between median score of the days with 1st day was neither statistically nor clinically significant. ODI has long term test re-test reliability in healthy subjects over a 1 month time interval.

  9. Construct Validity and Test-Retest Reliability of the Climbing Stairs Questionnaire in Lower-Limb Amputees

    NARCIS (Netherlands)

    de Laat, Fred A.; Rommers, Gerardus M.; Geertzen, Jan H.; Roorda, Leo D.

    de Laat FA, Rommers GM, Geertzen JH, Roorda LD. Construct validity and test-retest reliability of the Climbing Stairs Questionnaire in lower-limb amputees. Arch Phys Med Rehabil 2010;91:1396-401. Objective: To investigate the construct validity and test-retest reliability of the Climbing Stairs

  10. Test-Retest Reliability of the Salutogenic Wellness Promotion Scale (SWPS)

    Science.gov (United States)

    Anderson, L. M.; Moore, J. B.; Hayden, B. M.; Becker, C. M.

    2014-01-01

    Objective: This study examined the temporal stability (i.e. test-retest reliability) of the Salutogenic Wellness Promotion Scale (SWPS) using intraclass correlation coefficients (ICC). Current intraclass results were also compared to previously published interclass correlations to support the use of the intraclass method for test-retest…

  11. Test-retest reliability of the Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale.

    Science.gov (United States)

    Gustafsson, Margareta; Blomberg, Karin; Holmefur, Marie

    2015-07-01

    The Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale evaluates the student nurses' perception of the learning environment and supervision within the clinical placement. It has never been tested in a replication study. The aim of the present study was to evaluate the test-retest reliability of the CLES + T scale. The CLES + T scale was administered twice to a group of 42 student nurses, with a one-week interval. Test-retest reliability was determined by calculations of Intraclass Correlation Coefficients (ICCs) and weighted Kappa coefficients. Standard Error of Measurements (SEM) and Smallest Detectable Difference (SDD) determined the precision of individual scores. Bland-Altman plots were created for analyses of systematic differences between the test occasions. The results of the study showed that the stability over time was good to excellent (ICC 0.88-0.96) in the sub-dimensions "Supervisory relationship", "Pedagogical atmosphere on the ward" and "Role of the nurse teacher". Measurements of "Premises of nursing on the ward" and "Leadership style of the manager" had lower but still acceptable stability (ICC 0.70-0.75). No systematic differences occurred between the test occasions. This study supports the usefulness of the CLES + T scale as a reliable measure of the student nurses' perception of the learning environment within the clinical placement at a hospital. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  13. Test-retest reliability of the Military Pre-training Questionnaire.

    Science.gov (United States)

    Robinson, M; Stokes, K; Bilzon, J; Standage, M; Brown, P; Thompson, D

    2010-09-01

    Musculoskeletal injuries are a significant cause of morbidity during military training. A brief, inexpensive and user-friendly tool that demonstrates reliability and validity is warranted to effectively monitor the relationship between multiple predictor variables and injury incidence in military populations. To examine the test-retest reliability of the Military Pre-training Questionnaire (MPQ), designed specifically to assess risk factors for injury among military trainees across five domains (physical activity, injury history, diet, alcohol and smoking). Analyses were based on a convenience sample of 58 male British Army trainees. Kappa (kappa), weighted kappa (kappa(w)) and intraclass correlation coefficients (ICC) were used to evaluate the 2-week test-retest reliability of the MPQ. For index measures constituting the assessment of a given construct, internal consistency was assessed by Cronbach's alpha (alpha) coefficients. Reliability of individual items ranged from poor to almost perfect (kappa range = 0.45-0.86; kappa(w) range = 0.11-0.91; ICC range = 0.34-0.86) with most items demonstrating moderate reliability. Overall scores related to physical activity, diet, alcohol and smoking constructs were reliable between both administrations (ICC = 0.63-0.85). Support for the internal consistency of the incorporated alcohol (alpha = 0.78) and cigarette (alpha = 0.75) scales was also provided. The MPQ is a reliable self-report instrument for assessing multiple injury-related risk factors during initial military training. Further assessment of the psychometric properties of the MPQ (e.g. different types of validity) with military populations/samples will support its interpretation and use in future surveillance and epidemiological studies.

  14. Test-retest reliability and validity of the Sniffin' TOM odor memory test.

    Science.gov (United States)

    Croy, Ilona; Zehner, Cora; Larsson, Maria; Zucco, Gesualdo M; Hummel, Thomas

    2015-03-01

    Few attempts have been made to develop an olfactory test that captures episodic retention of olfactory information. Assessment of episodic odor memory is of particular interest in aging and in the cognitively impaired as both episodic memory deficits and olfactory loss have been targeted as reliable hallmarks of cognitive decline and impending dementia. Here, 96 healthy participants (18-92 years) and an additional 19 older people with mild cognitive impairment were tested (73-82 years). Participants were presented with 8 common odors with intentional encoding instructions that were followed by a yes-no recognition test. After recognition completion, participants were asked to identify all odors by means of free or cued identification. A retest of the odor memory test (Sniffin' TOM = test of odor memory) took place 17 days later. The results revealed satisfactory test-retest reliability (0.70) of odor recognition memory. Both recognition and identification performance were negatively affected by age and more pronounced among the cognitively impaired. In conclusion, the present work presents a reliable, valid, and simple test of episodic odor recognition memory that may be used in clinical groups where both episodic memory deficits and olfactory loss are prevalent preclinically such as Alzheimer's disease. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Test-retest reliability of the Danish Adult Reading Test in patients with comorbid psychosis and cannabis-use disorder

    DEFF Research Database (Denmark)

    Hjorthøj, Carsten Rygaard; Vesterager, Lone; Nordentoft, Merete

    2013-01-01

    Background: The New Adult Reading Test is a common instrument for assessing pre-morbid IQ for patients with, for instance, schizophrenia. However, test-retest reliability has not been established for patients dually diagnosed with psychosis and substance use disorder. Furthermore, test......-retest reliability of the Danish adaptation has never been established in any population. Aims: To determine the test-retest reliability of the Danish Adult Reading Test (DART) (adapted from the National Adult Reading Test, NART) for patients dually diagnosed with psychosis and cannabis-use disorder. Methods......: This was a secondary analysis of the CapOpus randomized trial. As part of the trial, 103 patients were randomized, and completed the DART up to three times. Pearson's r and pairwise t-tests were calculated. Results: DART score was independent of randomization, cannabis-use frequency and psychopathology. Scores...

  16. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep.

    Science.gov (United States)

    Wang, Jiahui; Han, Junwei; Nguyen, Vinh T; Guo, Lei; Guo, Christine C

    2017-01-01

    Resting state functional magnetic resonance imaging (rs-fMRI) provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV) derived from simultaneous electrocardiogram (ECG) recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  17. Laterality judgments in people with low back pain--A cross-sectional observational and test-retest reliability study.

    Science.gov (United States)

    Linder, Martin; Michaelson, Peter; Röijezon, Ulrik

    2016-02-01

    Disruption of cortical representation, or body schema, has been indicated as a factor in the persistence and recurrence of low back pain (LBP). This has been observed through impaired laterality judgment ability and it has been suggested that this ability is affected in a spatial rather than anatomical manner. We compared laterality judgment performance of foot and trunk movements between people with LBP with or without leg pain and healthy controls, and investigated associations between test performance and pain. We also assessed the test-retest reliability of the Recognise Online™ software when used in a clinical and a home setting. Cross-sectional observational and test-retest study. Thirty individuals with LBP and 30 healthy controls performed judgment tests of foot and trunk laterality once supervised in a clinic and twice at home. No statistically significant group differences were found. LBP intensity was negatively related to trunk laterality accuracy (p = 0.019). Intraclass correlation values ranged from 0.51 to 0.91. Reaction time improved significantly between test occasions while accuracy did not. Laterality judgments were not impaired in subjects with LBP compared to controls. Further research may clarify the relationship between pain mechanisms in LBP and laterality judgment ability. Reliability values were mostly acceptable, with wide and low confidence intervals, suggesting test-retest reliability for Recognise Online™ could be questioned in this trial. A significant learning effect was observed which should be considered in clinical and research application of the test. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. A reliability generalization meta-analysis of coefficient alpha and test-retest coefficient for the aging males' symptoms (AMS) scale.

    Science.gov (United States)

    Lee, Chin-Pang; Chiu, Yu-Wen; Chu, Chun-Lin; Chen, Yu; Jiang, Kun-Hao; Chen, Jiun-Liang; Chen, Ching-Yen

    2016-12-01

    The aging males' symptoms (AMS) scale is an instrument used to determine the health-related quality of life in adult and elderly men. The purpose of this study was to synthesize internal consistency (Cronbach's alpha) and test-retest reliability for the AMS scale and its three subscales. Of the 123 studies reviewed, 12 provided alpha coefficients which were then used in the meta-analyses of internal consistency. Seven of the 12 included studies provided test-retest coefficients, and these were used in the meta-analyses of test-retest reliability. The AMS scale had excellent internal consistency [α = 0.89 (95% CI 0.88-0.90)]; the mean alpha estimates across the AMS subscales ranged from 0.79 to 0.82. The AMS scale also had good test-retest reliability [r = 0.85 (95% CI 0.82-0.88]; the test-retest reliability coefficients of the AMS subscales ranged from 0.76 to 0.83. There was significant heterogeneity among the included studies. The AMS scale and the three subscales had fairly good internal consistency and test-retest reliability. Future psychometric studies of the AMS scale should report important characteristics of the participants, details of item scores, and test-retest reliability.

  19. Test - retest reliability of two instruments for measuring public attitudes towards persons with mental illness

    Directory of Open Access Journals (Sweden)

    Leufstadius Christel

    2011-01-01

    Full Text Available Abstract Background Research has identified stigmatization as a major threat to successful treatment of individuals with mental illness. As a consequence several anti-stigma campaigns have been carried out. The results have been discouraging and the field suffers from lack of evidence about interventions that work. There are few reports on psychometric data for instruments used to assess stigma, which thus complicates research efforts. The aim of the present study was to investigate test-retest reliability of the Swedish versions of the questionnaires: FABI and "Changing Minds" and to examine the internal consistency of the two instruments. Method Two instruments, fear and behavioural intentions (FABI and "Changing Minds", used in earlier studies on public attitudes towards persons with mental illness were translated into Swedish and completed by 51 nursing students on two occasions, with an interval of three weeks. Test-retest reliability was calculated by using weighted kappa coefficient and internal consistency using the Cronbach's alpha coefficient. Results Both instruments attain at best moderate test-retest reliability. For the Changing Minds questionnaire almost one fifth (17.9% of the items present poor test-retest reliability and the alpha coefficient for the subscales ranges between 0.19 - 0.46. All of the items in the FABI reach a fair or a moderate agreement between the test and retest, and the questionnaire displays a high internal consistency, alpha 0.80. Conclusions There is a need for development of psychometrically tested instruments within this field of research.

  20. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep

    Directory of Open Access Journals (Sweden)

    Jiahui Wang

    2017-05-01

    Full Text Available Resting state functional magnetic resonance imaging (rs-fMRI provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV derived from simultaneous electrocardiogram (ECG recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  1. Evaluating test-retest reliability in patient-reported outcome measures for older people: A systematic review.

    Science.gov (United States)

    Park, Myung Sook; Kang, Kyung Ja; Jang, Sun Joo; Lee, Joo Yun; Chang, Sun Ju

    2018-03-01

    This study aimed to evaluate the components of test-retest reliability including time interval, sample size, and statistical methods used in patient-reported outcome measures in older people and to provide suggestions on the methodology for calculating test-retest reliability for patient-reported outcomes in older people. This was a systematic literature review. MEDLINE, Embase, CINAHL, and PsycINFO were searched from January 1, 2000 to August 10, 2017 by an information specialist. This systematic review was guided by both the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist and the guideline for systematic review published by the National Evidence-based Healthcare Collaborating Agency in Korea. The methodological quality was assessed by the Consensus-based Standards for the selection of health Measurement Instruments checklist box B. Ninety-five out of 12,641 studies were selected for the analysis. The median time interval for test-retest reliability was 14days, and the ratio of sample size for test-retest reliability to the number of items in each measure ranged from 1:1 to 1:4. The most frequently used statistical methods for continuous scores was intraclass correlation coefficients (ICCs). Among the 63 studies that used ICCs, 21 studies presented models for ICC calculations and 30 studies reported 95% confidence intervals of the ICCs. Additional analyses using 17 studies that reported a strong ICC (>0.09) showed that the mean time interval was 12.88days and the mean ratio of the number of items to sample size was 1:5.37. When researchers plan to assess the test-retest reliability of patient-reported outcome measures for older people, they need to consider an adequate time interval of approximately 13days and the sample size of about 5 times the number of items. Particularly, statistical methods should not only be selected based on the types of scores of the patient-reported outcome measures, but should also be described clearly in

  2. Re-test reliability of gustatory testing and introduction of the sensitive Taste-Drop-Test

    DEFF Research Database (Denmark)

    Fjaeldstad, A; Niklassen, A; Fernandes, H

    2018-01-01

    . Testing gustatory function can be important for diagnostics and assessment of treatment effects. However, the gustatory tests applied are required to be both sensitive and reliable.In this study, we investigate the re-test validity of popular Taste Strips gustatory test for gustatory screening....... Furthermore, we introduce a new sensitive Taste-Drop-Test, which was found to be superior for detecting a more accurate measure of tastant sensitivity....

  3. A Test-Retest Reliability Study of the Whiplash Disability Questionnaire in Patients With Acute Whiplash-Associated Disorders

    DEFF Research Database (Denmark)

    Stupar, Maja; Côté, Pierre; Beaton, Dorcas E

    2015-01-01

    OBJECTIVE: The purpose of this study was to determine the test-retest reliability and the Minimal Detectable Change (MDC) of the Whiplash Disability Questionnaire (WDQ) in individuals with acute whiplash-associated disorders (WADs). METHODS: We performed a test-retest reliability study. We includ...

  4. Test-retest reliability and minimal detectable change of two simplified 3-point balance measures in patients with stroke.

    Science.gov (United States)

    Chen, Yi-Miau; Huang, Yi-Jing; Huang, Chien-Yu; Lin, Gong-Hong; Liaw, Lih-Jiun; Lee, Shih-Chieh; Hsieh, Ching-Lin

    2017-10-01

    The 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) were simplified from the BBS and PASS to overcome the complex scoring systems. The BBS-3P and PASS-3P were more feasible in busy clinical practice and showed similarly sound validity and responsiveness to the original measures. However, the reliability of the BBS-3P and PASS-3P is unknown limiting their utility and the interpretability of scores. We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BBS-3P and PASS-3P in patients with stroke. Cross-sectional study. The rehabilitation departments of a medical center and a community hospital. A total of 51 chronic stroke patients (64.7% male). Both balance measures were administered twice 7 days apart. The test-retest reliability of both the BBS-3P and PASS-3P were examined by intraclass correlation coefficients (ICC). The MDC and its percentage over the total score (MDC%) of each measure was calculated for examining the random measurement errors. The ICC values of the BBS-3P and PASS-3P were 0.99 and 0.97, respectively. The MDC% (MDC) of the BBS-3P and PASS-3P were 9.1% (5.1 points) and 8.4% (3.0 points), respectively, indicating that both measures had small and acceptable random measurement errors. Our results showed that both the BBS-3P and the PASS-3P had good test-retest reliability, with small and acceptable random measurement error. These two simplified 3-level balance measures can provide reliable results over time. Our findings support the repeated administration of the BBS-3P and PASS-3P to monitor the balance of patients with stroke. The MDC values can help clinicians and researchers interpret the change scores more precisely.

  5. Test-retest reliability and responsiveness of the Barthel Index-based Supplementary Scales in patients with stroke.

    Science.gov (United States)

    Lee, Ya-Chen; Yu, Wan-Hui; Hsueh, I-Ping; Chen, Sheng-Shiung; Hsieh, Ching-Lin

    2017-10-01

    A lack of evidence on the test-retest reliability and responsiveness limits the utility of the BI-based Supplementary Scales (BI-SS) in both clinical and research settings. To examine the test-retest reliability and responsiveness of the BI-based Supplementary Scales (BI-SS) in patients with stroke. A repeated-assessments design (1 week apart) was used to examine the test-retest reliability of the BI-SS. For the responsiveness study, the participants were assessed with the BI-SS and BI (treated as an external criterion) at admission to and discharge from rehabilitation wards. Seven outpatient rehabilitation units and one inpatient rehabilitation unit. Outpatients with chronic stroke. Eighty-four outpatients with chronic stroke participated in the test-retest reliability study. Fifty-seven inpatients completed baseline and follow-up assessments in the responsiveness study. For the test-retest reliability study, the values of the intra-class correlation coefficient and the overall percentage of minimal detectable change for the Ability Scale and Self-perceived Difficulty Scale were 0.97, 12.8%, and 0.78, 35.8%, respectively. For the responsiveness study, the standardized effect size and standardized response mean (representing internal responsiveness) of the Ability Scale and Self-perceived Difficulty Scale were 1.17 and 1.56, and 0.78 and 0.89, respectively. Regarding external responsiveness, the change in score of the Ability Scale had significant and moderate association with that of the BI (r=0.61, Ptest-retest reliability and sufficient responsiveness for patients with stroke. However, the Self-perceived Difficulty Scale of the BI-SS has substantial random measurement error and insufficient external responsiveness, which may affect its utility in clinical settings. The findings of this study provide empirical evidence of psychometric properties of the BI-SS for assessing ability and self-perceived difficulty of ADL in patients with stroke.

  6. Test-retest reliability and comparability of paper and computer questionnaires for the Finnish version of the Tampa Scale of Kinesiophobia.

    Science.gov (United States)

    Koho, P; Aho, S; Kautiainen, H; Pohjolainen, T; Hurri, H

    2014-12-01

    To estimate the internal consistency, test-retest reliability and comparability of paper and computer versions of the Finnish version of the Tampa Scale of Kinesiophobia (TSK-FIN) among patients with chronic pain. In addition, patients' personal experiences of completing both versions of the TSK-FIN and preferences between these two methods of data collection were studied. Test-retest reliability study. Paper and computer versions of the TSK-FIN were completed twice on two consecutive days. The sample comprised 94 consecutive patients with chronic musculoskeletal pain participating in a pain management or individual rehabilitation programme. The group rehabilitation design consisted of physical and functional exercises, evaluation of the social situation, psychological assessment of pain-related stress factors, and personal pain management training in order to regain overall function and mitigate the inconvenience of pain and fear-avoidance behaviour. The mean TSK-FIN score was 37.1 [standard deviation (SD) 8.1] for the computer version and 35.3 (SD 7.9) for the paper version. The mean difference between the two versions was 1.9 (95% confidence interval 0.8 to 2.9). Test-retest reliability was 0.89 for the paper version and 0.88 for the computer version. Internal consistency was considered to be good for both versions. The intraclass correlation coefficient for comparability was 0.77 (95% confidence interval 0.66 to 0.85), indicating substantial reliability between the two methods. Both versions of the TSK-FIN demonstrated substantial intertest reliability, good test-retest reliability, good internal consistency and acceptable limits of agreement, suggesting their suitability for clinical use. However, subjects tended to score higher when using the computer version. As such, in an ideal situation, data should be collected in a similar manner throughout the course of rehabilitation or clinical research. Copyright © 2014 Chartered Society of Physiotherapy. Published

  7. Evaluating the test-retest reliability of symptom indices associated with the ImPACT post-concussion symptom scale (PCSS).

    Science.gov (United States)

    Merritt, Victoria C; Bradson, Megan L; Meyer, Jessica E; Arnett, Peter A

    2018-05-01

    The Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is a commonly used tool in sports concussion assessment. While test-retest reliabilities have been established for the ImPACT cognitive composites, few studies have evaluated the psychometric properties of the ImPACT's Post-Concussion Symptom Scale (PCSS). The purpose of this study was to establish the test-retest reliability of symptom indices associated with the PCSS. Participants included 38 undergraduate students (50.0% male) who underwent neuropsychological testing as part of their participation in their psychology department's research subject pool. The majority of the participants were Caucasian (94.7%) and had no history of concussion (73.7%). All participants completed the ImPACT at two time points, approximately 6 weeks apart. The PCSS was the main outcome measure, and eight symptom indices were calculated (a total symptom score, three symptom summary indices, and four symptom clusters). Pearson correlations (r) and intraclass correlation coefficients (ICCs) were computed as measures of test-retest reliability. Overall, reliabilities ranged from low to high (r = .44 to .80; ICC = .44 to .77). The cognitive symptom cluster exhibited the highest test-retest reliability (r = .80, ICC = .77), followed by the positive symptom total (PST) index, an indicator of the total number of symptoms endorsed (r = .71, ICC = .69). In contrast, the commonly used total symptom score showed lower test-retest reliability (r = .67, ICC = .62). Paired-samples t tests revealed no significant differences between test and retest for any of the symptom variables (all p > .01). Finally, reliable change indices (RCI) were computed to determine whether differences observed between test and retest represented clinically significant change. RCI values were provided for each symptom index at the 80%, 90%, and 95% confidence intervals. These results suggest that evaluating additional symptom

  8. Test-Retest Reliability of Diffusion Tensor Imaging in Huntington's Disease.

    Science.gov (United States)

    Cole, James H; Farmer, Ruth E; Rees, Elin M; Johnson, Hans J; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z

    2014-03-21

    Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the intraclass correlation coefficient (ICC), was assessed using region-of-interest (ROI)-based white matter atlas and voxelwise approaches on repeat scan data from 22 participants (10 early HD, 12 controls). T1 data was used to generate further ROIs for analysis in a reduced sample of 18 participants. The results suggest that fractional anisotropy (FA) and other diffusivity metrics are generally highly reliable, with ICCs indicating considerably lower within-subject compared to between-subject variability in both HD patients and controls. Where ICC was low, particularly for the diffusivity measures in the caudate and putamen, this was partly influenced by outliers. The analysis suggests that the specific DTI methods used here are appropriate for cross-sectional research in HD, and give confidence that they can also be applied longitudinally, although this requires further investigation. An important caveat for DTI studies is that test-retest reliability may not be evenly distributed throughout the brain whereby highly anisotropic white matter regions tended to show lower relative within-subject variability than other white or grey matter regions.

  9. Test-retest reliability of the eating disorder examination-questionnaire (EDE-Q) in a college sample

    OpenAIRE

    Rose, Jennifer S; Vaewsorn, Adin; Rosselli-Navarra, Francine; Wilson, G Terence; Weissman, Ruth Striegel

    2013-01-01

    Background The Eating Disorder Examination-Questionnaire (EDE-Q), a widely used self-report instrument, is often used for measuring change in eating disorder symptoms over the course of treatment. However, limited data exist about test-retest reliability, particularly for men. The current study evaluated EDE-Q 7-day test-retest reliability in male (n = 47) and female (n = 44) undergraduate students together and separately by gender. Results Internal consistency was consistently higher for wom...

  10. Test-Retest Reliability of the Preschool Age Psychiatric Assessment (PAPA)

    Science.gov (United States)

    Egger, Helen Link; Erkanli, Alaattin; Keeler, Gordon; Potts, Edward; Walter, Barbara Keith; Angold, Adrian

    2006-01-01

    Objective: To examine the test-retest reliability of a new interviewer-based psychiatric diagnostic measure (the Preschool Age Psychiatric Assessment) for use with parents of preschoolers 2 to 5 years old. Method: A total of 1,073 parents of children attending a large pediatric clinic completed the Child Behavior Checklist 1 1/2-5. For 18 months,…

  11. Development, test-retest reliability, and construct validity of the resistance training skills battery.

    Science.gov (United States)

    Lubans, David R; Smith, Jordan J; Harries, Simon K; Barnett, Lisa M; Faigenbaum, Avery D

    2014-05-01

    The aim of this study was to describe the development and assess test-retest reliability and construct validity of the Resistance Training Skills Battery (RTSB) for adolescents. The RTSB provides an assessment of resistance training skill competency and includes 6 exercises (i.e., body weight squat, push-up, lunge, suspended row, standing overhead press, and front support with chest touches). Scoring for each skill is based on the number of performance criteria successfully demonstrated. An overall resistance training skill quotient (RTSQ) is created by adding participants' scores for the 6 skills. Participants (44 boys and 19 girls, mean age = 14.5 ± 1.2 years) completed the RTSB on 2 occasions separated by 7 days. Participants also completed the following fitness tests, which were used to create a muscular fitness score (MFS): handgrip strength, timed push-up, and standing long jump tests. Intraclass correlation (ICC), paired samples t-tests, and typical error were used to assess test-retest reliability. To assess construct validity, gender and RTSQ were entered into a regression model predicting MFS. The rank order repeatability of the RTSQ was high (ICC = 0.88). The model explained 39% of the variance in MFS (p ≤ 0.001) and RTSQ (r = 0.40, p ≤ 0.001) was a significant predictor. This study has demonstrated the construct validity and test-retest reliability of the RTSB in a sample of adolescents. The RTSB can reliably rank participants in regards to their resistance training competency and has the necessary sensitivity to detect small changes in resistance training skill proficiency.

  12. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease

    NARCIS (Netherlands)

    Strouwen, C.; Molenaar, E.A.; Keus, S.H.; Munks, L.; Bloem, B.R.; Nieuwboer, A.

    2016-01-01

    BACKGROUND: Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains

  13. Test-retest reliability of computer-based video analysis of general movements in healthy term-born infants.

    Science.gov (United States)

    Valle, Susanne Collier; Støen, Ragnhild; Sæther, Rannei; Jensenius, Alexander Refsum; Adde, Lars

    2015-10-01

    A computer-based video analysis has recently been presented for quantitative assessment of general movements (GMs). This method's test-retest reliability, however, has not yet been evaluated. The aim of the current study was to evaluate the test-retest reliability of computer-based video analysis of GMs, and to explore the association between computer-based video analysis and the temporal organization of fidgety movements (FMs). Test-retest reliability study. 75 healthy, term-born infants were recorded twice the same day during the FMs period using a standardized video set-up. The computer-based movement variables "quantity of motion mean" (Qmean), "quantity of motion standard deviation" (QSD) and "centroid of motion standard deviation" (CSD) were analyzed, reflecting the amount of motion and the variability of the spatial center of motion of the infant, respectively. In addition, the association between the variable CSD and the temporal organization of FMs was explored. Intraclass correlation coefficients (ICC 1.1 and ICC 3.1) were calculated to assess test-retest reliability. The ICC values for the variables CSD, Qmean and QSD were 0.80, 0.80 and 0.86 for ICC (1.1), respectively; and 0.80, 0.86 and 0.90 for ICC (3.1), respectively. There were significantly lower CSD values in the recordings with continual FMs compared to the recordings with intermittent FMs (ptest-retest reliability of computer-based video analysis of GMs, and a significant association between our computer-based video analysis and the temporal organization of FMs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Resting-state test-retest reliability of a priori defined canonical networks over different preprocessing steps.

    Science.gov (United States)

    Varikuti, Deepthi P; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T; Eickhoff, Simon B

    2017-04-01

    Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that gray matter masking improved the reliability of connectivity estimates, whereas denoising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources.

  15. Resting-state test-retest reliability of a priori defined canonical networks over different preprocessing steps

    Science.gov (United States)

    Varikuti, Deepthi P.; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T.; Eickhoff, Simon B.

    2016-01-01

    Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that grey matter masking improved the reliability of connectivity estimates, whereas de-noising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources. PMID:27550015

  16. Test-retest and between-site reliability in a multicenter fMRI study.

    Science.gov (United States)

    Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G

    2008-08-01

    In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.

  17. Influences on the Test-Retest Reliability of Functional Connectivity MRI and its Relationship with Behavioral Utility.

    Science.gov (United States)

    Noble, Stephanie; Spann, Marisa N; Tokoglu, Fuyuze; Shen, Xilin; Constable, R Todd; Scheinost, Dustin

    2017-11-01

    Best practices are currently being developed for the acquisition and processing of resting-state magnetic resonance imaging data used to estimate brain functional organization-or "functional connectivity." Standards have been proposed based on test-retest reliability, but open questions remain. These include how amount of data per subject influences whole-brain reliability, the influence of increasing runs versus sessions, the spatial distribution of reliability, the reliability of multivariate methods, and, crucially, how reliability maps onto prediction of behavior. We collected a dataset of 12 extensively sampled individuals (144 min data each across 2 identically configured scanners) to assess test-retest reliability of whole-brain connectivity within the generalizability theory framework. We used Human Connectome Project data to replicate these analyses and relate reliability to behavioral prediction. Overall, the historical 5-min scan produced poor reliability averaged across connections. Increasing the number of sessions was more beneficial than increasing runs. Reliability was lowest for subcortical connections and highest for within-network cortical connections. Multivariate reliability was greater than univariate. Finally, reliability could not be used to improve prediction; these findings are among the first to underscore this distinction for functional connectivity. A comprehensive understanding of test-retest reliability, including its limitations, supports the development of best practices in the field. © The Author 2017. Published by Oxford University Press.

  18. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    Science.gov (United States)

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e

  19. Test-Retest Reliability of Rating of Perceived Exertion and Agreement With 1-Repetition Maximum in Adults.

    Science.gov (United States)

    Bove, Allyn M; Lynch, Andrew D; DePaul, Samantha M; Terhorst, Lauren; Irrgang, James J; Fitzgerald, G Kelley

    2016-09-01

    Study Design Clinical measurement. Background It has been suggested that rating of perceived exertion (RPE) may be a useful alternative to 1-repetition maximum (1RM) to determine proper resistance exercise dosage. However, the test-retest reliability of RPE for resistance exercise has not been determined. Additionally, prior research regarding the relationship between 1RM and RPE is conflicting. Objectives The purpose of this study was to (1) determine test-retest reliability of RPE related to resistance exercise and (2) assess agreement between percentages of 1RM and RPE during quadriceps resistance exercise. Methods A sample of participants with and without knee pathology completed a series of knee extension exercises and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale, then repeated the procedure 1 to 2 weeks later for test-retest reliability. To determine agreement between RPE and 1RM, participants completed knee extension exercises at various percentages of their 1RM (10% to 130% of predicted 1RM) and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale. Percent agreement was calculated between the 1RM and RPE at each resistance interval. Results The intraclass correlation coefficient indicated excellent test-retest reliability of RPE for quadriceps resistance exercises (intraclass correlation coefficient = 0.895; 95% confidence interval: 0.866, 0.918). Overall percent agreement between RPE and 1RM was 60%, but agreement was poor within the ranges that would typically be used for training (50% 1RM for muscle endurance, 70% 1RM and greater for strength). Conclusion Test-retest reliability of perceived exertion during quadriceps resistance exercise was excellent. However, agreement between the RPE and 1RM was poor, especially in common training zones for knee extensor strengthening. J Orthop Sports Phys Ther 2016;46(9):768-774. Epub 5 Aug 2016. doi:10.2519/jospt.2016.6498.

  20. Test-retest, inter-assessor and intra-assessor reliability of the modified Touwen examination

    NARCIS (Netherlands)

    Peters, Lieke H. J.; Maathuis, Karel G. B.; Kouw, Eva; Hamming, Marjolein; Hadders-Algra, Mijna

    Interest in the Touwen examination (1979) for the assessment of minor neurological dysfunction (MND) is growing. However, information on psychometric properties of this assessment is scarce. Therefore the present study aimed at assessing the test's test-retest, inter- and intra-assessor reliability.

  1. The Physical Activity Scale for Individuals with Physical Disabilities: test-retest reliability and comparison with an accelerometer.

    Science.gov (United States)

    van der Ploeg, Hidde P; Streppel, Kitty R M; van der Beek, Allard J; van der Woude, Luc H V; Vollenbroek-Hutten, Miriam; van Mechelen, Willem

    2007-01-01

    The objective was to determine the test-retest reliability and criterion validity of the Physical Activity Scale for Individuals with Physical Disabilities (PASIPD). Forty-five non-wheelchair dependent subjects were recruited from three Dutch rehabilitation centers. Subjects' diagnoses were: stroke, spinal cord injury, whiplash, and neurological-, orthopedic- or back disorders. The PASIPD is a 7-d recall physical activity questionnaire that was completed twice, 1 wk apart. During this week, physical activity was also measured with an Actigraph accelerometer. The test-retest reliability Spearman correlation of the PASIPD was 0.77. The criterion validity Spearman correlation was 0.30 when compared to the accelerometer. The PASIPD had test-retest reliability and criterion validity that is comparable to well established self-report physical activity questionnaires from the general population.

  2. Stability of person ability measures in people with acquired brain injury in the use of everyday technology: the test-retest reliability of the Management of Everyday Technology Assessment (META).

    Science.gov (United States)

    Malinowsky, Camilla; Kassberg, Ann-Charlotte; Larsson-Lund, Maria; Kottorp, Anders

    2016-01-01

    To evaluate the test-retest reliability of the Management of Everyday Technology Assessment (META) in a sample of people with acquired brain injury (ABI). The META was administered twice within a two-week period to 25 people with ABI. A Rasch measurement model was used to convert the META ordinal raw scores into equal-interval linear measures of each participant's ability to manage everyday technology (ET). Test-retest reliability of the stability of the person ability measures in the META was examined by a standardized difference Z-test and an intra-class correlations analysis (ICC 1). The results showed that the paired person ability measures generated from the META were stable over the test-retest period for 22 of the 25 subjects. The ICC 1 correlation was 0.63, which indicates good overall reliability. The META demonstrated acceptable test-retest reliability in a sample of people with ABI. The results illustrate the importance of using sufficiently challenging ETs (relative to a person's abilities) to generate stable META measurements over time. Implications for Rehabilitation The findings add evidence regarding the test-retest reliability of the person ability measures generated from the observation assessment META in a sample of people with ABI. The META might support professionals in the evaluation of interventions that are designed to improve clients' performance of activities including the ability to manage ET.

  3. Test-retest reliability and smallest detectable change of the Bristol Impact of Hypermobility (BIoH) questionnaire.

    Science.gov (United States)

    Palmer, S; Manns, S; Cramp, F; Lewis, R; Clark, E M

    2017-12-01

    The Bristol Impact of Hypermobility (BIoH) questionnaire is a patient-reported outcome measure developed in conjunction with adults with Joint Hypermobility Syndrome (JHS). It has demonstrated strong concurrent validity with the Short Form-36 (SF-36) physical component score but other psychometric properties have yet to be established. This study aimed to determine its test-retest reliability and smallest detectable change (SDC). A test-retest reliability study. Participants were recruited from the Hypermobility Syndromes Association, a patient organisation in the United Kingdom. Recruitment packs were sent to 1080 adults who had given permission to be contacted about research. BIoH and SF-36 questionnaires were administered at baseline and repeated two weeks later. An 11-point global rating of change scale (-5 to +5) was also administered at two weeks. Test-retest analysis and calculation of the SDC was conducted on 'stable' patients (defined as global rating of change -1 to +1). 462 responses were received. 233 patients reported a 'stable' condition and were included in analysis (95% women; mean (SD) age 44.5 (13.9) years; BIoH score 223.6 (54.0)). The BIoH questionnaire demonstrated excellent test-retest reliability (ICC 0.923, 95% CI 0.900-0.940). The SDC was 42 points (equivalent to 19% of the mean baseline score). The SF-36 physical and mental component scores demonstrated poorer test-retest reliability and larger SDCs (as a proportion of the mean baseline scores). The results provide further evidence of the potential of the BIoH questionnaire to underpin research and clinical practice for people with JHS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Test-retest reliability of the driving habits questionnaire in older self-driving adults.

    Science.gov (United States)

    Song, Chiang-Soon; Chun, Byung-Yoon; Chung, Hyun-Sook

    2015-11-01

    [Purpose] The purpose of this study was to investigate the test-retest reliability of the Driving Habits Questionnaire in community-dwelling older self-drivers. [Subjects and Methods] Seventy-four participants were recruited by convenience sampling from local rehabilitation centers. This was a cross-sectional study design that used two clinical measures: the Driving Habits Questionnaire and Mini-mental State Examination. To examine the test-retest reliability of the Driving Habits Questionnaire, the clinical tool was measured twice, five days apart. [Results] The Driving Habits Questionnaire showed good reliability for older community-dwelling self-drivers. The Cronbach's alpha coefficients for the four domains of dependence (0.572), difficulty (0.871), crashes and citations (0.689), and driving space (0.961) of the Driving Habits Questionnaire indicated good or high internal consistency. Driving difficulty correlated significantly with self-reported crashes and citations and driving space. [Conclusion] The results of this study suggest that the Driving Habits Questionnaire is a reliable measure of self-reported interview-based driving behavior in the community-dwelling elderly.

  5. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    Science.gov (United States)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  6. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  7. Test-retest reliability of Eurofit Physical Fitness items for children with visual impairments

    NARCIS (Netherlands)

    Houwen, Suzanne; Visscher, Chris; Hartman, Esther; Lemmink, Koen A. P. M.

    The purpose of this study was to examine the test-retest reliability of physical fitness items from the European Test of Physical Fitness (Eurofit) for children with visual impairments. A sample of 21 children, ages 6-12 years, that were recruited from a special school for children with visual

  8. Test-retest reliability of selected items of Health Behaviour in School-aged Children (HBSC survey questionnaire in Beijing, China

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2010-08-01

    Full Text Available Abstract Background Children's health and health behaviour are essential for their development and it is important to obtain abundant and accurate information to understand young people's health and health behaviour. The Health Behaviour in School-aged Children (HBSC study is among the first large-scale international surveys on adolescent health through self-report questionnaires. So far, more than 40 countries in Europe and North America have been involved in the HBSC study. The purpose of this study is to assess the test-retest reliability of selected items in the Chinese version of the HBSC survey questionnaire in a sample of adolescents in Beijing, China. Methods A sample of 95 male and female students aged 11 or 15 years old participated in a test and retest with a three weeks interval. Student Identity numbers of respondents were utilized to permit matching of test-retest questionnaires. 23 items concerning physical activity, sedentary behaviour, sleep and substance use were evaluated by using the percentage of response shifts and the single measure Intraclass Correlation Coefficients (ICC with 95% confidence interval (CI for all respondents and stratified by gender and age. Items on substance use were only evaluated for school children aged 15 years old. Results The percentage of no response shift between test and retest varied from 32% for the item on computer use at weekends to 92% for the three items on smoking. Of all the 23 items evaluated, 6 items (26% showed a moderate reliability, 12 items (52% displayed a substantial reliability and 4 items (17% indicated almost perfect reliability. No gender and age group difference of the test-retest reliability was found except for a few items on sedentary behaviour. Conclusions The overall findings of this study suggest that most selected indicators in the HBSC survey questionnaire have satisfactory test-retest reliability for the students in Beijing. Further test-retest studies in a large

  9. Adaptation, test-retest reliability, and construct validity of the Physical Activity Neighborhood Environment Scale in Nigeria (PANES-N).

    Science.gov (United States)

    Oyeyemi, Adewale L; Sallis, James F; Oyeyemi, Adetoyeje Y; Amin, Mariam M; De Bourdeaudhuij, Ilse; Deforche, Benedicte

    2013-11-01

    This study adapted the Physical Activity Neighborhood Environment Scale (PANES) to the Nigerian context and assessed the test-retest reliability and construct validity of the Nigerian version (PANESN). A multidisciplinary panel of experts adapted the original PANES to reflect the built and social environment of Nigeria. The adapted PANES was subjected to cognitive testing and test retest reliability in a diverse sample of Nigerian adults (N = 132) from different neighborhood types. Intraclass Correlation Coefficients (ICC) was used to assess test-retest reliability, and construct validity was investigated with Analysis of Covariance for differences in environmental attributes between neighborhoods. Four of the 17 items on the original PANES were significantly modified, 3 were removed and 2 new items were incorporated into the final version of adapted PANES-N. Test-retest reliability was substantial to almost perfect (ICC = 0.62-1.00) for all items on the PANES-N, and residents of neighborhoods in the inner city reported higher residential density, land use mix and safety, but lower pedestrian facilities and aesthetics than did residents of government reserved area/new layout neighborhoods. The PANES-N appears promising for assessing environmental perceptions related to physical activity in Nigeria, but further testing is required to assess its applicability across Africa.

  10. Test-retest reliability of the 40 Hz EEG auditory steady-state response.

    Directory of Open Access Journals (Sweden)

    Kristina L McFadden

    Full Text Available Auditory evoked steady-state responses are increasingly being used as a marker of brain function and dysfunction in various neuropsychiatric disorders, but research investigating the test-retest reliability of this response is lacking. The purpose of this study was to assess the consistency of the auditory steady-state response (ASSR across sessions. Furthermore, the current study aimed to investigate how the reliability of the ASSR is impacted by stimulus parameters and analysis method employed. The consistency of this response across two sessions spaced approximately 1 week apart was measured in nineteen healthy adults using electroencephalography (EEG. The ASSR was entrained by both 40 Hz amplitude-modulated white noise and click train stimuli. Correlations between sessions were assessed with two separate analytical techniques: a channel-level analysis across the whole-head array and b signal-space projection from auditory dipoles. Overall, the ASSR was significantly correlated between sessions 1 and 2 (p<0.05, multiple comparison corrected, suggesting adequate test-retest reliability of this response. The current study also suggests that measures of inter-trial phase coherence may be more reliable between sessions than measures of evoked power. Results were similar between the two analysis methods, but reliability varied depending on the presented stimulus, with click train stimuli producing more consistent responses than white noise stimuli.

  11. Test-retest reliability of the Battery for the Assessment of Auditory Sensorimotor and Timing Abilities (BAASTA).

    Science.gov (United States)

    Bégel, Valentin; Verga, Laura; Benoit, Charles-Etienne; Kotz, Sonja A; Bella, Simone Dalla

    2018-04-27

    Perceptual and sensorimotor timing skills can be comprehensively assessed with the Battery for the Assessment of Auditory Sensorimotor and Timing Abilities (BAASTA). The battery has been used for testing rhythmic skills in healthy adults and patient populations (e.g., with Parkinson disease), showing sensitivity to timing and rhythm deficits. Here we assessed the test-retest reliability of the BAASTA in 20 healthy adults. Participants were tested twice with the BAASTA, implemented on a tablet interface, with a 2-week interval. They completed 4 perceptual tasks, namely, duration discrimination, anisochrony detection with tones and music, and the Beat Alignment Test (BAT). Moreover, they completed motor tasks via finger tapping, including unpaced and paced tapping with tones and music, synchronization-continuation, and adaptive tapping to a sequence with a tempo change. Despite high variability among individuals, the results showed stable test-retest reliability in most tasks. A slight but significant improvement from test to retest was found in tapping with music, which may reflect a learning effect. In general, the BAASTA was found a reliable tool for evaluating timing and rhythm skills. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  12. Questionnaire for measuring organisational attributes in dental-care practices: psychometric properties and test-retest reliability.

    Science.gov (United States)

    Goetz, Katja; Hasse, Philipp; Szecsenyi, Joachim; Campbell, Stephen M

    2016-04-01

    The consideration of organisational aspects, such as shared goals and clear communication, within the health care team is important to ensure good quality care. In primary health care, the instrument Survey of Organizational Attributes for Primary Care (SOAPC) is available to measure organisational attributes of care. However, there is no instrument available for dental care. The aim of the present study was to investigate psychometric properties and test-retest reliability of the version of SOAPC adapted for dental care, namely the Survey of Organizational Attributes in Dental Care (SOADC). The SOADC consists of 21 items in the following four subscales: communication; decision making; stress/chaos; and history of change. Convergent construct validity was measured using the job satisfaction scale. A total of 287 dental-care practices were asked to participate in the validation study. Psychometric properties and test-retest reliability were observed. A total of 43 dental-care practices responded to the survey. At baseline, 178 dental-care staff completed the questionnaire, and 4 weeks later 138 did so. Internal consistency, measured by Cronbach's alpha, was 0.718 or higher in the subscales. The test-retest reliability for each subscale and the overall SOADC score demonstrated good correlations over the 4-week test-retest interval, except for 'history of change'. A strong correlation with the aggregated job-satisfaction scale showed high convergent construct validity of SOADC. The consideration of organisational aspects from the perspective of dental-care teams is important for providing good quality of care. The SOADC is a reliable instrument with good psychometric properties and is suitable for the evaluation of organisational attributes in dental-care practices. © 2015 FDI World Dental Federation.

  13. The test-retest reliability of the latent construct of executive function depends on whether tasks are represented as formative or reflective indicators.

    Science.gov (United States)

    Willoughby, Michael T; Kuhn, Laura J; Blair, Clancy B; Samek, Anya; List, John A

    2017-10-01

    This study investigates the test-retest reliability of a battery of executive function (EF) tasks with a specific interest in testing whether the method that is used to create a battery-wide score would result in differences in the apparent test-retest reliability of children's performance. A total of 188 4-year-olds completed a battery of computerized EF tasks twice across a period of approximately two weeks. Two different approaches were used to create a score that indexed children's overall performance on the battery-i.e., (1) the mean score of all completed tasks and (2) a factor score estimate which used confirmatory factor analysis (CFA). Pearson and intra-class correlations were used to investigate the test-retest reliability of individual EF tasks, as well as an overall battery score. Consistent with previous studies, the test-retest reliability of individual tasks was modest (rs ≈ .60). The test-retest reliability of the overall battery scores differed depending on the scoring approach (r mean  = .72; r factor_ score  = .99). It is concluded that the children's performance on individual EF tasks exhibit modest levels of test-retest reliability. This underscores the importance of administering multiple tasks and aggregating performance across these tasks in order to improve precision of measurement. However, the specific strategy that is used has a large impact on the apparent test-retest reliability of the overall score. These results replicate our earlier findings and provide additional cautionary evidence against the routine use of factor analytic approaches for representing individual performance across a battery of EF tasks.

  14. Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department.

    Science.gov (United States)

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques S

    2016-01-01

    Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years ( M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r -values) between 0.5 and 0.8 across adjacent

  15. Test-retest reliability and stability of N400 effects in a word-pair semantic priming paradigm.

    Science.gov (United States)

    Kiang, Michael; Patriciu, Iulia; Roy, Carolyn; Christensen, Bruce K; Zipursky, Robert B

    2013-04-01

    Elicited by any meaningful stimulus, the N400 event-related potential (ERP) component is reduced when the stimulus is related to a preceding one. This N400 semantic priming effect has been used to probe abnormal semantic relationship processing in clinical disorders, and suggested as a possible biomarker for treatment studies. Validating N400 semantic priming effects as a clinical biomarker requires characterizing their test-retest reliability. We assessed test-retest reliability of N400 semantic priming in 16 healthy adults who viewed the same related and unrelated prime-target word pairs in two sessions one week apart. As expected, N400 amplitudes were smaller for related versus unrelated targets across sessions. N400 priming effects (amplitude differences between unrelated and related targets) were highly correlated across sessions (r=0.85, Pmotivational changes. Use of N400 priming effects in treatment studies should account for possible magnitude decreases with repeat testing. Further research is needed to delineate N400 priming effects' test-retest reliability and stability in different age and clinical groups, and with different stimulus types. Copyright © 2012 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  16. Development of an Agility Test for Badminton Players and Assessment of Its Validity and Test-Retest Reliability.

    Science.gov (United States)

    Loureiro, Luiz de França Bahia; de Freitas, Paulo Barbosa

    2016-04-01

    Badminton requires open and fast actions toward the shuttlecock, but there is no specific agility test for badminton players with specific movements. To develop an agility test that simultaneously assesses perception and motor capacity and examine the test's concurrent and construct validity and its test-retest reliability. The Badcamp agility test consists of running as fast as possible to 6 targets placed on the corners and middle points of a rectangular area (5.6 × 4.2 m) from the start position located in the center of it, following visual stimuli presented in a luminous panel. The authors recruited 43 badminton players (17-32 y old) to evaluate concurrent (with shuttle-run agility test--SRAT) and construct validity and test-retest reliability. Results revealed that Badcamp presents concurrent and construct validity, as its performance is strongly related to SRAT (ρ = 0.83, P < .001), with performance of experts being better than nonexpert players (P < .01). In addition, Badcamp is reliable, as no difference (P = .07) and a high intraclass correlation (ICC = .93) were found in the performance of the players on 2 different occasions. The findings indicate that Badcamp is an effective, valid, and reliable tool to measure agility, allowing coaches and athletic trainers to evaluate players' athletic condition and training effectiveness and possibly detect talented individuals in this sport.

  17. Test-retest reliability of the isernhagen work systems functional capacity evaluation in healthy adults

    NARCIS (Netherlands)

    Reneman, MF; Brouwer, S; Meinema, A; Dijkstra, PU; Geertzen, JHB; Groothoff, JW

    2004-01-01

    Aim of this study was to investigate test-retest reliability of the Isernhagen Work System Functional Capacity Evaluation (IWS FCE) in healthy subjects. The IWS FCE consists of 28 tests that reflect work-related activities such as lifting, carrying, bending, etc. A convenience sample of 26 healthy

  18. The Test-Retest Reliability of New Generation Power Indices of Wingate All-Out Test

    Directory of Open Access Journals (Sweden)

    Ozgur Ozkaya

    2018-04-01

    Full Text Available Although reliability correlations of traditional power indices of the Wingate test have been well documented, no study has analyzed new generation power indices based on milliseconds obtained from a Peak Bike. The purpose of this study was to investigate the retest reliability of new generation power indices. Thirty-two well-trained male athletes who were specialized in basketball, football, tennis, or track and field volunteered to take part in the study (age: 24.3 ± 2.2 years; body mass: 77 ± 8.3 kg; height: 180.3 ± 6.3 cm. Participants performed two Wingate all-out sessions on two separate days. Intra-class correlation coefficient (ICC, standard error measurement (SEM, smallest real differences (SRD and coefficient of variation (CV scores were analyzed based on the test and retest data. Reliability results of traditional power indices calculated based on 5-s means such as peak power, average power, power drop, and fatigue index ratio were similar with the previous findings in literature (ICC ≥ 0.94; CV ≤ 2.8%; SEM ≤ 12.28; SRD% ≤ 7.7%. New generation power indices such as peak power, average power, lowest power, power drop, fatigue index, power decline, maximum speed as rpm, and amount of total energy expenditure demonstrated high reliability (ICC ≥ 0.94; CV ≤ 4.3%; SEM ≤ 10.36; SRD% ≤ 8.8%. Time to peak power, time at maximum speed, and power at maximum speed showed a moderate level of reliability (ICC ≥ 0.73; CV ≤ 8.9%; SEM ≤ 63.01; SRD% ≤ 22.4%. The results of this study indicate that reliability correlations and SRD% of new generation power and fatigue-related indices are similar with traditional 5-s means. However, new time-related indices are very sensitive and moderately reliable.

  19. Test–Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study

    Directory of Open Access Journals (Sweden)

    Clare E. Palmer

    2018-01-01

    Full Text Available Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington’s disease (HD and Parkinson’s disease (PD across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test–retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test–retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test–retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT from the combined-Simon-Stop-Signal task showed moderate test–retest reliability, however, the combined SSRT interference effect showed poor test–retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  20. Interrater and Test-Retest Reliability and Minimal Detectable Change of the Balance Evaluation Systems Test (BESTest) and Subsystems With Community-Dwelling Older Adults.

    Science.gov (United States)

    Wang-Hsu, Elizabeth; Smith, Susan S

    2017-01-10

    Falls are a common cause of injuries and hospital admissions in older adults. Balance limitation is a potentially modifiable factor contributing to falls. The Balance Evaluation Systems Test (BESTest), a clinical balance measure, categorizes balance into 6 underlying subsystems. Each of the subsystems is scored individually and summed to obtain a total score. The reliability of the BESTest and its individual subsystems has been reported in patients with various neurological disorders and cancer survivors. However, the reliability and minimal detectable change (MDC) of the BESTest with community-dwelling older adults have not been reported. The purposes of our study were to (1) determine the interrater and test-retest reliability of the BESTest total and subsystem scores; and (2) estimate the MDC of the BESTest and its individual subsystem scores with community-dwelling older adults. We used a prospective cohort methodological design. Community-dwelling older adults (N = 70; aged 70-94 years; mean = 85.0 [5.5] years) were recruited from a senior independent living community. Trained testers (N = 3) administered the BESTest. All participants were tested with the BESTest by the same tester initially and then retested 7 to 14 days later. With 32 of the participants, a second tester concurrently scored the retest for interrater reliability. Testers were blinded to each other's scores. Intraclass correlation coefficients [ICC(2,1)] were used to determine the interrater and test-retest reliability. Test-retest reliability was also analyzed using method error and the associated coefficients of variation (CVME). MDC was calculated using standard error of measurement. Interrater reliability (N = 32) of the BESTest total score was ICC(2, 1) = 0.97 (95% confidence interval [CI], 0.94-0.99). The ICCs for the individual subsystem scores ranged from 0.85 to 0.94. Test-retest reliability (N = 70) of the BESTest total score was ICC(2,1) = 0.93 (95% CI, 0.89-0.96). ICCs for the

  1. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  2. Test-retest reliability of trunk motor variability measured by large-array surface electromyography.

    Science.gov (United States)

    Abboud, Jacques; Nougarou, François; Loranger, Michel; Descarreaux, Martin

    2015-01-01

    The objective of this study was to evaluate the test-retest reliability of the trunk muscle activity distribution in asymptomatic participants during muscle fatigue using large-array surface electromyography (EMG). Trunk muscle activity distribution was evaluated twice, with 3 to 4 days between them, in 27 asymptomatic volunteers using large-array surface EMG. Motor variability, assessed with 2 different variables (the centroid coordinates of the root mean square map and the dispersion variable), was evaluated during a low back muscle fatigue task. Test-retest reliability of muscle activity distribution was obtained using Pearson correlation coefficients. A shift in the distribution of EMG amplitude toward the lateral-caudal region of the lumbar erector spinae induced by muscle fatigue was observed. Moderate to very strong correlations were found between both sessions in the last 3 phases of the fatigue task for both motor variability variables, whereas weak to moderate correlations were found in the first phases of the fatigue task only for the dispersion variable. These findings show that, in asymptomatic participants, patterns of EMG activity are less reliable in initial stages of muscle fatigue, whereas later stages are characterized by highly reliable patterns of EMG activity. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  3. Test-Retest Reliability and Practice Effects of the Stability Evaluation Test.

    Science.gov (United States)

    Williams, Richelle M; Corvo, Matthew A; Lam, Kenneth C; Williams, Travis A; Gilmer, Lesley K; McLeod, Tamara C Valovich

    2017-01-17

    Postural control plays an essential role in concussion evaluation. The Stability Evaluation Test (SET) aims to objectively analyze postural control by measuring sway velocity on the NeuroCom's VSR portable force platform (Natus, San Carlos, CA). To assess the test-retest reliability and practice effects of the SET protocol. Cohort. Research Laboratory. Fifty healthy adults (males=20, females=30, age=25.30±3.60 years, height=166.60±12.80 cm, mass=68.80±13.90 kg). All participants completed four trials of the SET. Each trial consisted of six 20-second balance tests with eyes closed, under the following conditions: double-leg firm (DFi), single-leg firm (SFi), tandem firm (TFi), double-leg foam (DFo), single-leg foam (SFo), and tandem foam (TFo). Each trial was separated by a 5-minute seated rest period. The dependent variable was sway velocity (deg/sec), with lower values indicating better balance. Sway velocity was recorded for each of the six conditions as well as a composite score for each trial. Test-retest reliability was analyzed across four trials with Intraclass Correlation Coefficients. Practice effects analyzed with repeated measures analysis of variance, followed by Tukey post-hoc comparisons for any significant main effects (preliability values were good to excellent: DFi (ICC=0.88;95%CI:0.81,0.92), SFi (ICC=0.75;95%CI:0.61,0.85), TFi (ICC=0.84;95%CI:0.75,0.90), DFo (ICC=0.83;95%CI:0.74,0.90), SFo (ICC=0.82;95%CI:0.72,0.89), TFo (ICC=0.81;95%CI:0.69,0.88), and composite score (ICC=0.93;95%CI:0.88,0.95). Significant practice effects (preliability for the assessment of postural control in healthy adults. Due to the practice effects noted, a familiarization session is recommended (i.e., all 6 conditions) prior to recording the data. Future studies should evaluate injured patients to determine meaningful change scores during various injuries.

  4. Test-Retest Reliability of Self-Reported Sexual Health Measures among US Hispanic Adolescents

    Science.gov (United States)

    Jerman, Petra; Berglas, Nancy F.; Rohrbach, Louise A.; Constantine, Norman A.

    2016-01-01

    Objective: Although Hispanic adolescents in the USA are often the focus of sexual health interventions, their response to survey measures has rarely been assessed within evaluation studies. This study documents the test-retest reliability of a wide range of self-reported sexual health values, attitudes, knowledge and behaviours among Hispanic…

  5. Test-retest reliability of the 20-sec Wingate test to assess anaerobic power in children with cerebral palsy

    NARCIS (Netherlands)

    Dallmeijer, A.J.; Scholtes, V.A.B.; Brehm, M.A.; Becher, J.G.

    2013-01-01

    OBJECTIVE: The aim of this study was to determine the test-retest reliability of the 20-sec Wingate anaerobic test in children with cerebral palsy. DESIGN: Participants were 22 ambulant children with cerebral palsy, with Gross Motor Function Classification System levels I (limitations in advanced

  6. Test-Retest Reliability of the 20-sec Wingate Test to Assess Anaerobic Power in Children with Cerebral Palsy

    NARCIS (Netherlands)

    Dallmeijer, Annet J.; Scholtes, Vanessa A. B.; Brehm, Merel-Anne; Becher, Jules G.

    2013-01-01

    Objective: The aim of this study was to determine the test-retest reliability of the 20-sec Wingate anaerobic test in children with cerebral palsy. Design: Participants were 22 ambulant children with cerebral palsy, with Gross Motor Function Classification System levels I (limitations in advanced

  7. Test-retest reliability and practice effects of the Wechsler Memory Scale-III.

    Science.gov (United States)

    Lo, Ada H Y; Humphreys, Michael; Byrne, Gerard J; Pachana, Nancy A

    2012-09-01

    Although serial administration of cognitive tests is increasingly common, there is a paucity of research on test-retest reliabilities and practice effects, both of which are important for evaluating changes in functioning. Reliability is generally conceptualized as involving short-lasting changes in performance. However, when repeated testing occurs over a period of years, there will be some longer lasting effects. The implications of these longer lasting effects and practice effects on reliability were examined in the context of repeated administrations of the Wechsler Memory Scale-III in 339 community-dwelling women aged 40-79 years over 2 to 7 years. The results showed that Logical Memory and Verbal Paired Associates subtests were consistently the most reliable subtests across the age cohorts. The magnitude of practice effects varied as a function of subtests and age. The largest practice effects were found in the youngest age cohort, especially on the Faces, Logical Memory, and Verbal Paired Associates subtests. ©2012 The British Psychological Society.

  8. Maximal cardiorespiratory fitness testing in individuals with chronic stroke with cognitive impairment: practice test effects and test-retest reliability.

    Science.gov (United States)

    Olivier, Charles; Doré, Jean; Blanchet, Sophie; Brooks, Dina; Richards, Carol L; Martel, Guy; Robitaille, Nancy-Michelle; Maltais, Désirée B

    2013-11-01

    To evaluate, for individuals with chronic stroke with cognitive impairment, (1) the effects of a practice test on peak cardiorespiratory fitness test results; (2) cardiorespiratory fitness test-retest reliability; and (3) the relationship between individual practice test effects and cognitive impairment. Cross-sectional. Rehabilitation center. A convenience sample of 21 persons (men [n=12] and women [n=9]; age range, 48-81y; 44.9±36.2mo poststroke) with cognitive impairments who had sufficient lower limb function to perform the test. Not applicable. Peak oxygen consumption (Vo(2)peak, ml·kg(-1)·min(-1)). Test-retest reliability of Vo(2)peak was excellent (intraclass correlation coefficient model 2,1 [ICC2,1]=.94; 95% confidence interval [CI], .86-.98). A paired t test showed that there was no significant difference for the group for Vo(2)peak obtained from 2 symptom-limited cardiorespiratory fitness tests performed 1 week apart on a semirecumbent cycle ergometer (test 2-test 1 difference, -.32ml·kg(-1)·min(-1); 95% CI, -.69 to 1.33ml·kg(-1)·min(-1); P=.512). Individual test-retest differences in Vo(2)peak were, however, positively related to general cognitive function as measured by the Mini-Mental State Examination (ρ=.485; Preliably measured in this group without a practice test. General cognitive function, however, may influence the effect of a practice test in that those with lower general cognitive function appear to respond differently to a practice test than those with higher cognitive function. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. We need more replication research - A case for test-retest reliability.

    Science.gov (United States)

    Leppink, Jimmie; Pérez-Fuster, Patricia

    2017-06-01

    Following debates in psychology on the importance of replication research, we have also started to see pleas for a more prominent role for replication research in medical education. To enable replication research, it is of paramount importance to carefully study the reliability of the instruments we use. Cronbach's alpha has been the most widely used estimator of reliability in the field of medical education, notably as some kind of quality label of test or questionnaire scores based on multiple items or of the reliability of assessment across exam stations. However, as this narrative review outlines, Cronbach's alpha or alternative reliability statistics may complement but not replace psychometric methods such as factor analysis. Moreover, multiple-item measurements should be preferred above single-item measurements, and when using single-item measurements, coefficients as Cronbach's alpha should not be interpreted as indicators of the reliability of a single item when that item is administered after fundamentally different activities, such as learning tasks that differ in content. Finally, if we want to follow up on recent pleas for more replication research, we have to start studying the test-retest reliability of the instruments we use.

  10. Intensity response function of the photopic negative response (PhNR): effect of age and test-retest reliability.

    Science.gov (United States)

    Joshi, Nabin R; Ly, Emma; Viswanathan, Suresh

    2017-08-01

    To assess the effect of age and test-retest reliability of the intensity response function of the full-field photopic negative response (PhNR) in normal healthy human subjects. Full-field electroretinograms (ERGs) were recorded from one eye of 45 subjects, and 39 of these subjects were tested on two separate days with a Diagnosys Espion System (Lowell, MA, USA). The visual stimuli consisted of brief (test-retest reliability was assessed with the Wilcoxon signed-rank test and Bland-Altman analysis. Holm's correction was applied to account for multiple comparisons. V max of BT was significantly smaller than that of PT and b-wave, and the V max of PT and b-wave was not significantly different from each other. The slope parameter n was smallest for BT and the largest for b-wave and the difference between the slopes of all three measures were statistically significant. Small differences observed in the mean values of K for the different measures did not reach statistical significance. The Wilcoxon signed-rank test indicated no significant differences between the two test visits for any of the Naka-Rushton parameters for the three ERG measures, and the Bland-Altman plots indicated that the mean difference between test and retest measurements of the different fit parameters was close to zero and within 6% of the average of the test and retest values of the respective parameters for all three ERG measurements, indicating minimal bias. While the coefficient of reliability (COR, defined as 1.96 times the standard deviation of the test and retest difference) of each fit parameter was more or less comparable across the three ERG measurements, the %COR (COR normalized to the mean test and retest measures) was generally larger for BT compared to both PT and b-wave for each fit parameter. The Naka-Rushton fit parameters did not show statistically significant changes with age for any of the ERG measures when corrections were applied for multiple comparisons. However, the V max of

  11. Test-Retest Reliability of Handgrip Strength as an Outcome Measure in Patients With Symptoms of Shoulder Impingement Syndrome.

    Science.gov (United States)

    Savva, Christos; Mougiaris, Paraskevas; Xadjimichael, Christoforos; Karagiannis, Christos; Efstathiou, Michalis

    The purpose of this study was to investigate the degree of test-retest reliability of grip strength measurement using a hand dynamometer in patients with shoulder impingement syndrome. A total of 19 patients (10 women and 9 men; mean ± standard deviation age, 33.2 ± 12.9 years; range 18-59 years) with shoulder impingement syndrome were measured using a hand dynamometer by the same data collector in 2 different testing sessions with a 7-day interval. During each session, patients were encouraged to exert 3 maximal isometric contractions on the affected hand and the mean value of the 3 efforts (measured in kilogram-force [Kgf]) was used for data analysis. The intraclass correlation coefficient (ICC 2,1 ) as well as the standard error of measurement (SEM) and Bland-Altman plot were used to estimate the degree of test-retest reliability and the measurement error, respectively. Grip strength data analysis revealed an ICC 2,1 score of 0.94, which, based on the Shrout classification, is considered as excellent test-retest reliability of grip strength measurement. The small values of SEMs reported in both sessions (SEM 1 , 2.55 Kgf; SEM 2 , 2.39 Kgf) and the small width of the 95% limits of agreement in the Bland-Altman plot (ranging from -7.39 Kgf to 7.03 Kgf) reflected the measurement precision and the narrow variation of the differences during the 2 testing sessions. Results from this study identified excellent test-retest reliability of grip strength measurement in shoulder impingement syndrome, indicating its potential use as an outcome measure in clinical practice. Copyright © 2018. Published by Elsevier Inc.

  12. Temporal Stability of Strength-Based Assessments: Test-Retest Reliability of Student and Teacher Reports

    Science.gov (United States)

    Romer, Natalie; Merrell, Kenneth W.

    2013-01-01

    This study focused on evaluating the temporal stability of self-reported and teacher-reported perceptions of students' social and emotional skills and assets. We used a test-retest reliability procedure over repeated administrations of the child, adolescent, and teacher versions of the "Social-Emotional Assets and Resilience Scales".…

  13. Test-retest reliability of stride time variability while dual tasking in healthy and demented adults with frontotemporal degeneration

    Directory of Open Access Journals (Sweden)

    Herrmann Francois R

    2011-07-01

    Full Text Available Abstract Background Although test-retest reliability of mean values of spatio-temporal gait parameters has been assessed for reliability while walking alone (i.e., single tasking, little is known about the test-retest reliability of stride time variability (STV while performing an attention demanding-task (i.e., dual tasking. The objective of this study was to examine immediate test-retest reliability of STV while single and dual tasking in cognitively healthy older individuals (CHI and in demented patients with frontotemporal degeneration (FTD. Methods Based on a cross-sectional design, 69 community-dwelling CHI (mean age 75.5 ± 4.3; 43.5% women and 14 demented patients with FTD (mean age 65.7 ± 9.8 years; 6.7% women walked alone (without performing an additional task; i.e., single tasking and while counting backward (CB aloud starting from 50 (i.e., dual tasking. Each subject completed two trials for all the testing conditions. The mean value and the coefficient of variation (CoV of stride time while walking alone and while CB at self-selected walking speed were measured using GAITRite® and SMTEC® footswitch systems. Results ICC of mean value in CHI under both walking conditions were higher than ICC of demented patients with FTD and indicated perfect reliability (ICC > 0.80. Reliability of mean value was better while single tasking than dual tasking in CHI (ICC = 0.96 under single-task and ICC = 0.86 under dual-task, whereas it was the opposite in demented patients (ICC = 0.65 under single-task and ICC = 0.81 under dual-task. ICC of CoV was slight to poor whatever the group of participants and the walking condition (ICC Conclusions The immediate test-retest reliability of the mean value of stride time in single and dual tasking was good in older CHI as well as in demented patients with FTD. In contrast, the variability of stride time was low in both groups of participants.

  14. Establishing survey validity and reliability for American Indians through "think aloud" and test-retest methods.

    Science.gov (United States)

    Hauge, Cindy Horst; Jacobs-Knight, Jacque; Jensen, Jamie L; Burgess, Katherine M; Puumala, Susan E; Wilton, Georgiana; Hanson, Jessica D

    2015-06-01

    The purpose of this study was to use a mixed-methods approach to determine the validity and reliability of measurements used within an alcohol-exposed pregnancy prevention program for American Indian women. To develop validity, content experts provided input into the survey measures, and a "think aloud" methodology was conducted with 23 American Indian women. After revising the measurements based on this input, a test-retest was conducted with 79 American Indian women who were randomized to complete either the original measurements or the new, modified measurements. The test-retest revealed that some of the questions performed better for the modified version, whereas others appeared to be more reliable for the original version. The mixed-methods approach was a useful methodology for gathering feedback on survey measurements from American Indian participants and in indicating specific survey questions that needed to be modified for this population. © The Author(s) 2015.

  15. Feasibility and test-retest reliability of measuring lower‑limb strength in young children with cerebral palsy.

    Science.gov (United States)

    Van Vulpen, L F; De Groot, S; Becher, J G; De Wolf, G S; Dallmeijer, A J

    2013-12-01

    Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions) of measuring lower-limb strength with handheld dynamometry (HHD) and dynamic ankle plantar flexor strength with the standing heel-rise (SH) test in 3-10 year aged children with CP. Test-retest design. Rehabilitation centre, special needs school for children with disabilities, and university medical centre. Knee extensor, hip abductor and calf muscle strength was assessed in 20 ambulatory children with spastic CP (3-5 years [N.=10] and 6-10 years [N.=10]) on two test occasions. Intraclass correlation coefficients (ICC) and Smallest Detectable Differences (SDD) were calculated to determine the optimal test design for detecting changes in strength. All isometric strength tests had acceptable SDDs (9-30%), when taking the mean values of 2-3 test occasions (separate days) and 2-3 repetitions. The one-leg SH test had large SDDs (40-128% for younger group, 23-48% for older group). Isometric strength (improvements) can only be measured reliably with HHD in young children with CP when the average values over at least 2 test occasions are taken. Reliability of the SH test is not sufficient for measuring individual changes in dynamic muscle strength in the younger children. Results of this study can be used to determine the optimal number of test occasions and repetitions for reliable HHD measurements depending on expected changes, muscle group and age in 3-10 year old children with CP.

  16. Test-retest reliability and construct validity of the ENERGY-child questionnaire on energy balance-related behaviours and their potential determinants: the ENERGY-project

    Directory of Open Access Journals (Sweden)

    Singh Amika S

    2011-12-01

    Full Text Available Abstract Background Insight in children's energy balance-related behaviours (EBRBs and their determinants is important to inform obesity prevention research. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. Objective To examine the test-retest reliability and construct validity of the child questionnaire used in the ENERGY-project, measuring EBRBs and their potential determinants among 10-12 year old children. Methods We collected data among 10-12 year old children (n = 730 in the test-retest reliability study; n = 96 in the construct validity study in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent face-to-face interview was assessed using ICC and percentage agreement. Results Of the 150 questionnaire items, 115 (77% showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Test-retest reliability was moderate for 34 items (23% and poor for one item. Construct validity appeared to be good to excellent for 70 (47% of the 150 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 80 items, construct validity was moderate for 39 (26% and poor for 41 items (27%. Conclusions Our results demonstrate that the ENERGY-child questionnaire, assessing EBRBs of the child as well as personal, family, and school-environmental determinants related to these EBRBs, has good test-retest reliability and moderate to good construct validity for the large majority of items.

  17. Test-retest reliability and construct validity of the ENERGY-child questionnaire on energy balance-related behaviours and their potential determinants: the ENERGY-project

    Science.gov (United States)

    2011-01-01

    Background Insight in children's energy balance-related behaviours (EBRBs) and their determinants is important to inform obesity prevention research. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. Objective To examine the test-retest reliability and construct validity of the child questionnaire used in the ENERGY-project, measuring EBRBs and their potential determinants among 10-12 year old children. Methods We collected data among 10-12 year old children (n = 730 in the test-retest reliability study; n = 96 in the construct validity study) in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC) and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent face-to-face interview was assessed using ICC and percentage agreement. Results Of the 150 questionnaire items, 115 (77%) showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Test-retest reliability was moderate for 34 items (23%) and poor for one item. Construct validity appeared to be good to excellent for 70 (47%) of the 150 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 80 items, construct validity was moderate for 39 (26%) and poor for 41 items (27%). Conclusions Our results demonstrate that the ENERGY-child questionnaire, assessing EBRBs of the child as well as personal, family, and school-environmental determinants related to these EBRBs, has good test-retest reliability and moderate to good construct validity for the large majority of items. PMID:22152048

  18. Test-retest reliability of barbell velocity during the free-weight bench-press exercise.

    Science.gov (United States)

    Stock, Matt S; Beck, Travis W; DeFreitas, Jason M; Dillon, Michael A

    2011-01-01

    The purpose of this study was to calculate test-retest reliability statistics for peak barbell velocity during the free-weight bench-press exercise for loads corresponding to 10-90% of the 1-repetition maximum (1RM). Twenty-one healthy, resistance-trained men (mean ± SD age = 23.5 ± 2.7 years; body mass = 90.5 ± 14.6 kg; 1RM bench press = 125.4 ± 18.4 kg) volunteered for this study. A minimum of 48 hours after a maximal strength testing and familiarization session, the subjects performed single repetitions of the free-weight bench-press exercise at each tenth percentile (10-90%) of the 1RM on 2 separate occasions. For each repetition, the subjects were instructed to press the barbell as rapidly as possible, and peak barbell velocity was measured with a Tendo Weightlifting Analyzer. The test-retest intraclass correlation coefficients (model 2,1) and corresponding standard errors of measurement (expressed as percentages of the mean barbell velocity values) were 0.717 (4.2%), 0.572 (5.0%), 0.805 (3.1%), 0.669 (4.7%), 0.790 (4.6%), 0.785 (4.8%), 0.811 (5.8%), 0.714 (10.3%), and 0.594 (12.6%) for the weights corresponding to 10-90% 1RM. There were no mean differences between the barbell velocity values from trials 1 and 2. These results indicated moderate to high test-retest reliability for barbell velocity from 10 to 70% 1RM but decreased consistency at 80 and 90% 1RM. When examining barbell velocity during the free-weight bench-press exercise, greater measurement error must be overcome at 80 and 90% 1RM to be confident that an observed change is meaningful.

  19. Test-retest reliability at the item level and total score level of the Norwegian version of the Spinal Cord Injury Falls Concern Scale (SCI-FCS).

    Science.gov (United States)

    Roaldsen, Kirsti Skavberg; Måøy, Åsa Blad; Jørgensen, Vivien; Stanghelle, Johan Kvalvik

    2016-05-01

    Translation of the Spinal Cord Injury Falls Concern Scale (SCI-FCS), and investigation of test-retest reliability on item-level and total-score-level. Translation, adaptation and test-retest study. A specialized rehabilitation setting in Norway. Fifty-four wheelchair users with a spinal cord injury. The median age of the cohort was 49 years, and the median number of years after injury was 13. Interventions/measurements: The SCI-FCS was translated and back-translated according to guidelines. Individuals answered the SCI-FCS twice over the course of one week. We investigated item-level test-retest reliability using Svensson's rank-based statistical method for disagreement analysis of paired ordinal data. For relative reliability, we analyzed the total-score-level test-retest reliability with intraclass correlation coefficients (ICC2.1), the standard error of measurement (SEM), and the smallest detectable change (SDC) for absolute reliability/measurement-error assessment and Cronbach's alpha for internal consistency. All items showed satisfactory percentage agreement (≥69%) between test and retest. There were small but non-negligible systematic disagreements among three items; we recovered an 11-13% higher chance for a lower second score. There was no disagreement due to random variance. The test-retest agreement (ICC2.1) was excellent (0.83). The SEM was 2.6 (12%), and the SDC was 7.1 (32%). The Cronbach's alpha was high (0.88). The Norwegian SCI-FCS is highly reliable for wheelchair users with chronic spinal cord injuries.

  20. Establishing the Test-Retest Reliability & Concurrent Validity for the Repeat Ice Skating Test (RIST) in Adolescent Male Ice Hockey Players

    Science.gov (United States)

    Power, Allan; Faught, Brent E.; Przysucha, Eryk; McPherson, Moira; Montelpare, William

    2012-01-01

    In this study the authors examine the test-retest reliability and concurrent validity of the Repeat Ice Skating Test (RIST). This was an on-ice field anaerobic test that measured average peak power and was validated with 3 anaerobic lab tests: (a) vertical jump, (b) the Margaria-Kalamen stair test, and (c) the Wingate Anaerobic Test. The…

  1. Test-retest reliability of Brazilian version of Memorial Symptom Assessment Scale for assessing symptoms in cancer patients.

    Science.gov (United States)

    Menezes, Josiane Roberta de; Luvisaro, Bianca Maria Oliveira; Rodrigues, Claudia Fernandes; Muzi, Camila Drumond; Guimarães, Raphael Mendonça

    2017-01-01

    To assess the test-retest reliability of the Memorial Symptom Assessment Scale translated and culturally adapted into Brazilian Portuguese. The scale was applied in an interview format for 190 patients with various cancers type hospitalized in clinical and surgical sectors of the Instituto Nacional de Câncer José de Alencar Gomes da Silva and reapplied in 58 patients. Data from the test-retest were double typed into a Microsoft Excel spreadsheet and analyzed by the weighted Kappa. The reliability of the scale was satisfactory in test-retest. The weighted Kappa values obtained for each scale item had to be adequate, the largest item was 0.96 and the lowest was 0.69. The Kappa subscale was also evaluated and values were 0.84 for high frequency physic symptoms, 0.81 for low frequency physical symptoms, 0.81 for psychological symptoms, and 0.78 for Global Distress Index. High level of reliability estimated suggests that the process of measurement of Memorial Symptom Assessment Scale aspects was adequate. Avaliar a confiabilidade teste-reteste da versão traduzida e adaptada culturalmente para o português do Brasil do Memorial Symptom Assessment Scale. A escala foi aplicada em forma de entrevista em 190 pacientes com diversos tipos de câncer internados nos setores clínicos e cirúrgicos do Instituto Nacional de Câncer José de Alencar Gomes da Silva e reaplicada em 58 pacientes. Os dados dos testes-retestes foram inseridos num banco de dados por dupla digitação independente em Excel e analisados pelo Kappa ponderado. A confiabilidade da escala mostrou-se satisfatória nos testes-retestes. Os valores do Kappa ponderado obtidos para cada item da escala apresentaram-se adequados, sendo o maior item de 0,96 e o menor de 0,69. Também se avaliou o Kappa das subescalas, sendo de 0,84 para sintomas físicos de alta frequência, de 0,81 para sintomas físicos de baixa frequência, de 0,81 também para sintomas psicológicos, e de 0,78 para Índice Geral de Sofrimento

  2. Test-retest Agreement and Reliability of Quantitative Sensory Testing 1 Year After Breast Cancer Surgery

    DEFF Research Database (Denmark)

    Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner

    2015-01-01

    .5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. DISCUSSION: The QST protocol reliability allows for group......OBJECTIVES: Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine...... persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim...

  3. Test-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table.

    Science.gov (United States)

    Saengsuwan, Jittima; Berger, Lucia; Schuster-Amft, Corina; Nef, Tobias; Hunt, Kenneth J

    2016-09-06

    Exercise testing devices for evaluating cardiopulmonary fitness in patients with severe disability after stroke are lacking, but we have adapted a robotics-assisted tilt table (RATT) for cardiopulmonary exercise testing (CPET). Using the RATT in a sample of patients after stroke, this study aimed to investigate test-retest reliability and repeatability of CPET and to prospectively investigate changes in cardiopulmonary outcomes over a period of four weeks. Stroke patients with all degrees of disability underwent 3 separate CPET sessions: 2 tests at baseline (TB1 and TB2) and 1 test at follow up (TF). TB1 and TB2 were at least 24 h apart. TB2 and TF were 4 weeks apart. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and a real-time visual feedback system was used to guide the patients' exercise work rate during CPET. Test-retest reliability and repeatability of CPET variables were analysed using paired t-tests, the intraclass correlation coefficient (ICC), the coefficient of variation (CoV), and Bland and Altman limits of agreement. Changes in cardiopulmonary fitness during four weeks were analysed using paired t-tests. Seventeen sub-acute and chronic stroke patients (age 62.7 ± 10.4 years [mean ± SD]; 8 females) completed the test sessions. The median time post stroke was 350 days. There were 4 severely disabled, 1 moderately disabled and 12 mildly disabled patients. For test-retest, there were no statistically significant differences between TB1 and TB2 for most CPET variables. Peak oxygen uptake, peak heart rate, peak work rate and oxygen uptake at the ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) showed good to excellent test-retest reliability (ICC 0.65-0.94). For all CPET variables, CoV was 4.1-14.5 %. The mean difference was close to zero in most of the CPET variables. There were no significant changes in most cardiopulmonary performance parameters during the 4-week period

  4. TEST-RETEST RELIABILITY OF THE CLOSED KINETIC CHAIN UPPER EXTREMITY STABILITY TEST (CKCUEST) IN ADOLESCENTS: RELIABILITY OF CKCUEST IN ADOLESCENTS.

    Science.gov (United States)

    de Oliveira, Valéria M A; Pitangui, Ana C R; Nascimento, Vinícius Y S; da Silva, Hítalo A; Dos Passos, Muana H P; de Araújo, Rodrigo C

    2017-02-01

    The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clinimetric values for this test. Test-retest reliability. Twenty-five healthy adolescents of both sexes were evaluated. The subjects performed two CKCUEST with an interval of one week between the tests. An intraclass correlation coefficient (ICC 3,3 ) two-way mixed model with a 95% interval of confidence was utilized to determine intersession reliability. A Bland-Altman graph was plotted to analyze the agreement between assessments. The presence of systematic error was evaluated by a one-sample t test. The difference between the evaluation and reevaluation was observed using a paired-sample t test. The level of significance was set at 0.05. Standard error of measurements and minimum detectable changes were calculated. The intersession reliability of the average touches score, normalized score, and power score were 0.68, 0.68 and 0.87, the standard error of measurement were 2.17, 1.35 and 6.49, and the minimal detectable change was 6.01, 3.74 and 17.98, respectively. The presence of systematic error (p test with moderate to excellent reliability when used with adolescents. The CKCUEST is a measurement with moderate to excellent reliability for adolescents. 2b.

  5. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  6. Reliability of the Swedish version of the Exercise Self-Efficacy Scale (S-ESES): a test-retest study in adults with neurological disease.

    Science.gov (United States)

    Ahlström, Isabell; Hellström, Karin; Emtner, Margareta; Anens, Elisabeth

    2015-03-01

    To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency. Test-retest study. A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot-Marie-Tooth disease. The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated. The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2). The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.

  7. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease.

    Science.gov (United States)

    Strouwen, Carolien; Molenaar, Esther A L M; Keus, Samyra H J; Münks, Liesbeth; Bloem, Bastiaan R; Nieuwboer, Alice

    2016-08-01

    Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains largely unknown. The purpose of this study was to assess the reliability of DT outcome measures in patients with PD. A repeated-measures design was used. Patients with PD ("on" medication, Mini-Mental State Examination score ≥24) performed 2 cognitive tasks (ie, backward digit span task and auditory Stroop task) and 1 functional task (ie, mobile phone task) in combination with walking. Tasks were assessed at 2 time points (same hour) with an interval of 6 weeks. Test-retest reliability was assessed for gait while performing each secondary task (DT gait) for both cognitive tasks while walking (DT cognitive) and for the functional task while walking (DT functional). Sixty-two patients with PD (age=39-89 years, Hoehn and Yahr stages II-III) were included in the study. Intraclass correlation coefficients (ICCs) showed excellent reliability for DT gait measures, ranging between .86 and .95 when combined with the digit span task, between .86 and .95 when combined with the auditory Stroop task, and between .72 and .90 when combined with the mobile phone task. The standard error of measurements for DT gait speed varied between 0.06 and 0.08 m/s, leading to minimal detectable changes between 0.16 and 0.22 m/s. With regard to DT cognitive measures, reaction times showed good-to-excellent reliability (digit span task: ICC=.75; auditory Stroop task: ICC=.82). The results cannot be generalized to patients with advanced disease or to other DT measures. In people with PD, DT measures proved to be reliable for use in clinical studies and look promising for use in clinical practice to assess improvements after DT training. Large effects, however, are needed to obtain meaningful effect sizes.

  8. Response process and test-retest reliability of the Context Assessment for Community Health tool in Vietnam.

    Science.gov (United States)

    Duc, Duong M; Bergström, Anna; Eriksson, Leif; Selling, Katarina; Thi Thu Ha, Bui; Wallin, Lars

    2016-01-01

    The recently developed Context Assessment for Community Health (COACH) tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources, community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment) through 49 items. The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test-retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC) and percent agreement) and dimensions (ICC and Bland-Altman plots). In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test-retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5-0.7), demonstrating that the instrument has an acceptable level of stability. This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify some items and to further review items with low ICC.

  9. Test-retest reliability and construct validity of the Helplessness, Hopelessness, and Haplessness Scale in patients with anxiety disorders.

    Science.gov (United States)

    Vatan, Sevginar; Ertaş, Sedar; Lester, David

    2011-04-01

    In a sample of 100 Turkish psychiatric patients with diagnoses of anxiety disorders, Lester's Helplessness, Hopelessness, and Haplessness inventory had moderate estimates of internal consistency, test-retest reliability, and construct validity.

  10. The Physical Activity Scale for Individuals with Physical Disabilities : test-retest reliability and comparison with an accelerometer

    NARCIS (Netherlands)

    van der Ploeg, Hidde P; Streppel, Kitty R M; van der Beek, Allard J; van der Woude, Luc H V; Vollenbroek-Hutten, Miriam; van Mechelen, Willem; van der Woude, Lucas

    BACKGROUND: The objective was to determine the test-retest reliability and criterion validity of the Physical Activity Scale for Individuals with Physical Disabilities (PASIPD). METHODS: Forty-five non-wheelchair dependent subjects were recruited from three Dutch rehabilitation centers. Subjects'

  11. Test-retest reliability of the Middlesex Assessment of Mental State (MEAMS): a preliminary investigation in people with probable dementia.

    Science.gov (United States)

    Powell, T; Brooker, D J; Papadopolous, A

    1993-05-01

    Relative and absolute test-retest reliability of the MEAMS was examined in 12 subjects with probable dementia and 12 matched controls. Relative reliability was good. Measures of absolute reliability showed scores changing by up to 3 points over an interval of a week. A version effect was found to be in evidence.

  12. Test-retest reliability of an interactive voice response (IVR) version of the EORTC QLQ-C30

    NARCIS (Netherlands)

    Lundy, J.J.; Coons, S.J.; Aaronson, N.K.

    2015-01-01

    Objective: The objective of this study was to assess the test-retest reliability of an interactive voice response (IVR) version of the European Organisation for Research and Treatment of Cancer (EORTC) QLQ-C30. Methods: A convenience sample of outpatient cancer clinic patients (n = 127) was asked to

  13. Construct Validity and Test-Retest Reliability of the Walking Questionnaire in People With a Lower Limb Amputation

    NARCIS (Netherlands)

    de Laat, Fred A.; Rommers, Gerardus M.; Geertzen, Jan H.; Roorda, Leo D.

    Objective: To investigate the construct validity and test-retest reliability of the Walking Questionnaire, a patient-reported measure of activity limitations in walking in people with a lower limb amputation. Design: Cross-sectional study. Setting: Outpatient department of a rehabilitation center.

  14. Test Re-Test Reliability of Four Versions of the 3-Cone Test in Non-Athletic Men

    Directory of Open Access Journals (Sweden)

    Jason G. Langley, Robert D. Chetlin

    2017-03-01

    Full Text Available Until recently, measurement and evaluation in sport science, especially agility testing, has not always included key elements of proper test construction. Often tests are published without reporting reliability and validity analysis for a specific population. The purpose of the present study was to examine the test re-test reliability of four versions of the 3-Cone Test (3CT, and provide guidance on proper test construction for testing agility in athletic populations. Forty male students enrolled in classes in the Department of Physical Education at a mid-Atlantic university participated. On each of test day participants performed 10 trials. In random order, they performed three trials to the right (3CTR, standard test, three to the left (3CTL, and two modified trials (3CTAR and 3CTAL, which included a reactive component in which a visual cue was given to indicate direction. Intra-class correlation coefficients (ICC indicated a moderate to high reliability for the four tests, 3CTR 0.79 (0.64-0.88, 95%CI, 3CTL 0.73 (0.55-0.85, 3CTAR 0.85(0.74-0.92, and 3CTAL 0.79 (0.64-0.88. Small standard error of the measurement (SEM was found; range 0.09 to 0.10. Pearson correlations between tests were high (0.82-0.92 on day one as well as day two (0.72-0.85. These results indicate each version of the 3-Cone Test is reliable; however, further tests are needed with specific athletic populations. Only the 3CTAR and 3CTAL are tests of agility due to the inclusion of a reactive component. Future studies examining agility testing and training should incorporate technological elements, including automated timing systems and motion capture analysis. Such instrumentation will allow for optimal design of tests that simulate sport-specific game conditions.

  15. Test-retest reliability and predictors of unreliable reporting for a sexual behavior questionnaire for U.S. men.

    Science.gov (United States)

    Nyitray, Alan G; Harris, Robin B; Abalos, Andrew T; Nielson, Carrie M; Papenfuss, Mary; Giuliano, Anna R

    2010-12-01

    Accurate knowledge about human sexual behaviors is important for increasing our understanding of human sexuality; however, there have been few studies assessing the reliability of sexual behavior questionnaires designed for community samples of adult men. A test-retest reliability study was conducted on a questionnaire completed by 334 men who had been recruited in Tucson, Arizona. Reliability coefficients and refusal rates were calculated for 39 non-sexual and sexual behavior questionnaire items. Predictors of unreliable reporting for lifetime number of female sexual partners were also assessed. Refusal rates were generally low, with slightly higher refusal rates for questions related to immigration, income, the frequency of sexual intercourse with women, lifetime number of female sexual partners, and the lifetime number of male anal sex partners. Kappa and intraclass correlation coefficients were substantial or almost perfect for all non-sexual and sexual behavior items. Reliability dropped somewhat, but was still substantial, for items that asked about household income and the men's knowledge of their sexual partners' health, including abnormal Pap tests and prior sexually transmitted diseases (STD). Age and lifetime number of female sexual partners were independent predictors of unreliable reporting while years of education was inversely associated with unreliable reporting. These findings among a community sample of adult men are consistent with other test-retest reliability studies with populations of women and adolescents.

  16. Confiabilidade teste-reteste de aspectos da rede social no Estudo Pró-Saúde Test-retest reliability of measures of social network in the "Pró-Saúde" Study

    Directory of Open Access Journals (Sweden)

    Rosane Harter Griep

    2003-06-01

    Full Text Available OBJETIVO: Avaliar os níveis de confiabilidade teste-reteste de informações relativas à rede social no Estudo Pró-saúde. MÉTODOS: Foi estimada a confiabilidade pelo estudo teste-reteste por meio de questionário multidimensional aplicado a uma coorte de trabalhadores de uma universidade. O mesmo questionário foi preenchido duas vezes por 192 funcionários não efetivos da universidade, com duas semanas de intervalo entre as aplicações. A concordância foi estimada pela estatística Kappa (variáveis categóricas, estatística Kappa ponderado e modelos log-lineares (variáveis ordinais, e coeficiente de correlação intraclasse (variáveis discretas. RESULTADOS: As medidas de concordância situaram-se acima de 0,70 para a maioria das variáveis. Estratificando-se as informações segundo gênero, idade e escolaridade, observou-se que a confiabilidade não apresentou padrão consistente de variabilidade. A aplicação de modelos log-lineares indicou que, para as variáveis ordinais do estudo, o modelo de melhor ajuste foi o de "concordância diagonal mais associação linear por linear". CONCLUSÕES: Os altos níveis de confiabilidade estimados permitem concluir que o processo de aferição dos itens sobre rede social foi adequado para as características investigadas. Estudos de validação em andamento complementarão a avaliação da qualidade dessas informações.OBJECTIVE: To evaluate test-retest reliability of social network-related information of the" Pró-Saúde" study. METHODS: A test-retest reliability study was conducted using a multidimensional questionnaire applied to a cohort of university employees. The same questionnaire was filled out twice by 192 non-permanent employees with two weeks apart. Agreement was estimated using kappa statistics (categorical variables, weighted kappa statistics, log-linear models (ordinal variables, and intraclass correlation coefficient (discrete variables. RESULTS: Estimates of reliability

  17. Test-retest reliability of an fMRI paradigm for studies of cardiovascular reactivity.

    Science.gov (United States)

    Sheu, Lei K; Jennings, J Richard; Gianaros, Peter J

    2012-07-01

    We examined the reliability of measures of fMRI, subjective, and cardiovascular reactions to standardized versions of a Stroop color-word task and a multisource interference task. A sample of 14 men and 12 women (30-49 years old) completed the tasks on two occasions, separated by a median of 88 days. The reliability of fMRI BOLD signal changes in brain areas engaged by the tasks was moderate, and aggregating fMRI BOLD signal changes across the tasks improved test-retest reliability metrics. These metrics included voxel-wise intraclass correlation coefficients (ICCs) and overlap ratio statistics. Task-aggregated ratings of subjective arousal, valence, and control, as well as cardiovascular reactions evoked by the tasks showed ICCs of 0.57 to 0.87 (ps reliability. These findings support using these tasks as a battery for fMRI studies of cardiovascular reactivity. Copyright © 2012 Society for Psychophysiological Research.

  18. Rorschach e pedofilia: a fidedignidade no teste-reteste = Rorschach and pedophilia: a reliability at test-retest

    Directory of Open Access Journals (Sweden)

    Scortegagna, Silvana Alba

    2013-01-01

    Full Text Available Esse estudo buscou investigar as características de personalidade de um indivíduo pedófilo, e evidenciar a fidedignidade do Rorschach no teste-reteste. O participante, com 38 anos de idade, masculino, respondeu a entrevista e ao método de Rorschach, em duas etapas. Os principais achados revelam: a uma tendência à fragmentação na percepção de si e dos outros; b autoimagem negativa e desfavorável em relação ao corpo e suas funções; c problemas nas relações interpessoais, falhas na capacidade de empatia; d déficit no ajustamento perceptivo da realidade; e vulnerabilidade a pressões subjetivas e impulsividade. Esses resultados mantiveram-se estáveis comparando-se as duas aplicações, permitindo ampliar a compreensão dos elementos psicológicos envolvidos na pedofilia, que se mantem, e apoiam a fidedignidade do Rorschach no teste-reteste

  19. Inter-Rater and Test-Retest (Between-Sessions) Reliability of the 4-Skills Scan for Dutch Elementary School Children

    Science.gov (United States)

    van Kernebeek, Willem G.; de Schipper, Antoine W.; Savelsbergh, Geert J. P.; Toussaint, Huub M.

    2018-01-01

    In The Netherlands, the 4-Skills Scan is an instrument for physical education teachers to assess gross motor skills of elementary school children. Little is known about its reliability. Therefore, in this study the test-retest and inter-rater reliability was determined. Respectively, 624 and 557 Dutch 6- to 12-year-old children were analyzed for…

  20. Test-retest reliability of the diagnosis of schizoaffective disorder in childhood and adolescence - A systematic review and meta-analysis.

    Science.gov (United States)

    Salamon, Sarah; Santelmann, Hanno; Franklin, Jeremy; Baethge, Christopher

    2018-04-01

    Reliability of schizoaffective disorder (SAD) diagnoses is low in adults but unclear in children and adolescents (CAD). We estimate the test-retest reliability of SAD and its key differential diagnoses (schizophrenia, bipolar disorder, and unipolar depression). Systematic literature search of Medline, Embase, and PsycInfo for studies on test-retest reliability of SAD, in CAD. Cohen's kappa was extracted from studies. We performed meta-analysis for kappa, including subgroup and sensitivity analysis (PROSPERO protocol: CRD42013006713). Out of > 4000 records screened, seven studies were included. We estimated kappa values of 0.27 [95%-CI: 0.07 0.47] for SAD, 0.56 [0.29; 0.83] for schizophrenia, 0.64 [0.55; 0.74] for bipolar disorder, and 0.66 [0.52; 0.81] for unipolar depression. In 5/7 studies kappa of SAD was lower than that of schizophrenia; similar trends emerged for bipolar disorder (4/5) and unipolar depression (2/3). Estimates of positive agreement of SAD diagnoses supported these results. The number of studies and patients included is low. The point-estimate of the test-retest reliability of schizoaffective disorder is only fair, and lower than that of its main differential diagnoses. All kappa values under study were lower in children and adolescents samples than those reported for adults. Clinically, schizoaffective disorder should be diagnosed in strict adherence to the operationalized criteria and ought to be re-evaluated regularly. Should larger studies confirm the insufficient reliability of schizoaffective disorder in children and adolescents, the clinical value of the diagnosis is highly doubtful. Copyright © 2017. Published by Elsevier B.V.

  1. Test-retest reliability of a questionnaire to assess physical environmental factors pertaining to physical activity

    Directory of Open Access Journals (Sweden)

    McGinn Aileen P

    2005-06-01

    Full Text Available Abstract Background Despite the documented benefits of physical activity, many adults do not obtain the recommended amounts. Barriers to physical activity occur at multiple levels, including at the individual, interpersonal, and environmental levels. Only until more recently has there been a concerted focus on how the physical environment might affect physical activity behavior. With this new area of study, self-report measures should be psychometrically tested before use in research studies. Therefore the objective of this study was to document the test-retest reliability of a questionnaire designed to assess physical environmental factors that might be associated with physical activity in a diverse adult population. Methods Test and retest surveys were conducted over the telephone with 106 African American and White women and men living in either Forsyth County, North Carolina or Jackson, Mississippi. Reliability of self-reported environmental factors across four domains (e.g., access to facilities and destinations, functionality and safety, aesthetics, natural environment was determined using intraclass correlation coefficients (ICC overall and separately by gender and race. Results Generally items displayed moderate and sometimes substantial reliability (ICC between 0.4 to 0.8, with a few differences by gender or race, across each of the domains. Conclusion This study provides some psychometric evidence for the use of many of these questions in studies examining the effect of self-reported physical environmental measures on physical activity behaviors, among African American and White women and men.

  2. Work-related measures of physical and behavioral health function: Test-retest reliability.

    Science.gov (United States)

    Marino, Molly Elizabeth; Meterko, Mark; Marfeo, Elizabeth E; McDonough, Christine M; Jette, Alan M; Ni, Pengsheng; Bogusz, Kara; Rasch, Elizabeth K; Brandt, Diane E; Chan, Leighton

    2015-10-01

    The Work Disability Functional Assessment Battery (WD-FAB), developed for potential use by the US Social Security Administration to assess work-related function, currently consists of five multi-item scales assessing physical function and four multi-item scales assessing behavioral health function; the WD-FAB scales are administered as Computerized Adaptive Tests (CATs). The goal of this study was to evaluate the test-retest reliability of the WD-FAB Physical Function and Behavioral Health CATs. We administered the WD-FAB scales twice, 7-10 days apart, to a sample of 376 working age adults and 316 adults with work-disability. Intraclass correlation coefficients were calculated to measure the consistency of the scores between the two administrations. Standard error of measurement (SEM) and minimal detectable change (MDC90) were also calculated to measure the scales precision and sensitivity. For the Physical Function CAT scales, the ICCs ranged from 0.76 to 0.89 in the working age adult sample, and 0.77-0.86 in the sample of adults with work-disability. ICCs for the Behavioral Health CAT scales ranged from 0.66 to 0.70 in the working age adult sample, and 0.77-0.80 in the adults with work-disability. The SEM ranged from 3.25 to 4.55 for the Physical Function scales and 5.27-6.97 for the Behavioral Health function scales. For all scales in both samples, the MDC90 ranged from 7.58 to 16.27. Both the Physical Function and Behavioral Health CATs of the WD-FAB demonstrated good test-retest reliability in adults with work-disability and general adult samples, a critical requirement for assessing work related functioning in disability applicants and in other contexts. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  4. Test-retest reliability of behavioral measures of impulsive choice, impulsive action, and inattention.

    Science.gov (United States)

    Weafer, Jessica; Baggott, Matthew J; de Wit, Harriet

    2013-12-01

    Behavioral measures of impulsivity are widely used in substance abuse research, yet relatively little attention has been devoted to establishing their psychometric properties, especially their reliability over repeated administration. The current study examined the test-retest reliability of a battery of standardized behavioral impulsivity tasks, including measures of impulsive choice (i.e., delay discounting, probability discounting, and the Balloon Analogue Risk Task), impulsive action (i.e., the stop signal task, the go/no-go task, and commission errors on the continuous performance task), and inattention (i.e., attention lapses on a simple reaction time task and omission errors on the continuous performance task). Healthy adults (n = 128) performed the battery on two separate occasions. Reliability estimates for the individual tasks ranged from moderate to high, with Pearson correlations within the specific impulsivity domains as follows: impulsive choice (r range: .76-.89, ps reliable measures and thus can be confidently used to assess various facets of impulsivity as intermediate phenotypes for drug abuse.

  5. Test-retest reliability and construct validity of the DOiT (Dutch Obesity Intervention in Teenagers) questionnaire: measuring energy balance-related behaviours in Dutch adolescents.

    Science.gov (United States)

    Janssen, Evelien H C; Singh, Amika S; van Nassau, Femke; Brug, Johannes; van Mechelen, Willem; Chinapaw, Mai J M

    2014-02-01

    Adequate assessment of energy balance-related behaviours in adolescents is essential to develop and evaluate effective obesity prevention programmes. The present study examined the test-retest reliability and construct validity of a questionnaire assessing energy balance-related behaviours in adolescents during the evaluation of the DOiT (Dutch Obesity Intervention in Teenagers) intervention. To assess test-retest reliability, adolescents filled in the questionnaire twice (n 111). To assess construct validity, the results from the first test were compared with data collected in a personal cognitive interview (n 20, independent from the reliability study). For both reliability and validity, intraclass correlation coefficients for continuous data or Cohen's kappa coefficients for categorical data were calculated as well as percentage agreement. Data were collected during school time from February to May 2010. Study participants were Dutch adolescents aged 12-14 years attending pre-vocational secondary schools. In more than three-quarters of the ninety-five questionnaire items the test-retest reliability appeared to be good to excellent. Moderate reliability was found for all other twenty-one items. Fifty-one items (of ninety-five items) showed good to excellent construct validity. Construct validity appeared moderate in twenty-three items and poor in twenty-one items. Most items with poor construct validity concerned consumption of sugar-containing beverages and high-energy snacks/sweets. Our study showed good test-retest reliability and largely moderate to good construct validity for the majority of items of the DOiT questionnaire. Items with poor construct validity (most of them found for items concerning energy intake-related behaviours) should be revised and tested again to improve the questionnaire for future use.

  6. Test-retest reliability and task order effects of emotional cognitive tests in healthy subjects.

    Science.gov (United States)

    Adams, Thomas; Pounder, Zoe; Preston, Sally; Hanson, Andy; Gallagher, Peter; Harmer, Catherine J; McAllister-Williams, R Hamish

    2016-11-01

    Little is known of the retest reliability of emotional cognitive tasks or the impact of using different tasks employing similar emotional stimuli within a battery. We investigated this in healthy subjects. We found improved overall performance in an emotional attentional blink task (EABT) with repeat testing at one hour and one week compared to baseline, but the impact of an emotional stimulus on performance was unchanged. Similarly, performance on a facial expression recognition task (FERT) was better one week after a baseline test, though the relative effect of specific emotions was unaltered. There was no effect of repeat testing on an emotional word categorising, recall and recognition task. We found no difference in performance in the FERT and EABT irrespective of task order. We concluded that it is possible to use emotional cognitive tasks in longitudinal studies and combine tasks using emotional facial stimuli in a single battery.

  7. The eye-complaint questionnaire in a visual display unit work environment: Internal consistency and test-retest reliability

    NARCIS (Netherlands)

    Steenstra, Ivan A.; Sluiter, Judith K.; Frings-Dresen, Monique H. W.

    2009-01-01

    The internal consistency and test-retest reliability of a 10-item eye-complaint questionnaire (ECQ) were examined within a sample of office workers. Repeated within-subjects measures were performed within a single day and over intervals of 1 and 7 d. Questionnaires were completed by 96 workers (70%

  8. Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG Test in Patients with Parkinson's Disease.

    Directory of Open Access Journals (Sweden)

    Rob C van Lummel

    Full Text Available The "Timed Up and Go" (TUG is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson's Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG], the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information.The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson's Disease.Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability.Nineteen ICC values (15% were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49% were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24% were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12% were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2% were < 0.30 indicating very poor reliability.In conclusion, in patients with Parkinson's disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements

  9. Test-Retest Reliability of the Parent Behavior Importance Questionnaire-Revised and the Parent Behavior Frequency Questionnaire-Revised

    Science.gov (United States)

    Mowder, Barbara A.; Shamah, Renee

    2011-01-01

    This study evaluated the test-retest reliability of two parenting measures: the Parent Behavior Importance Questionnaire-Revised (PBIQ-R) and Parent Behavior Frequency Questionnaire-Revised (PBFQ-R). These self-report parenting behavior assessment measures may be utilized as pre- and post-parent education program measures, with parents as well as…

  10. Test-retest reliability of Antonovsky's 13-item sense of coherence scale in patients with hand-related disorders

    DEFF Research Database (Denmark)

    Hansen, Alice Ørts; Kristensen, Hanne Kaae; Cederlund, Ragnhild

    2017-01-01

    to be a powerful tool to measure the ICF component personal factors, which could have an impact on patients' rehabilitation outcomes. Implications for rehabilitation Antonovsky's SOC-13 scale showed test-retest reliability for patients with hand-related disorders. The SOC-13 scale could be a suitable tool to help...... measure personal factors....

  11. The reliability of WorkWell Systems Functional Capacity Evaluation: a systematic review

    Science.gov (United States)

    2014-01-01

    Background Functional capacity evaluation (FCE) determines a person’s ability to perform work-related tasks and is a major component of the rehabilitation process. The WorkWell Systems (WWS) FCE (formerly known as Isernhagen Work Systems FCE) is currently the most commonly used FCE tool in German rehabilitation centres. Our systematic review investigated the inter-rater, intra-rater and test-retest reliability of the WWS FCE. Methods We performed a systematic literature search of studies on the reliability of the WWS FCE and extracted item-specific measures of inter-rater, intra-rater and test-retest reliability from the identified studies. Intraclass correlation coefficients ≥ 0.75, percentages of agreement ≥ 80%, and kappa coefficients ≥ 0.60 were categorised as acceptable, otherwise they were considered non-acceptable. The extracted values were summarised for the five performance categories of the WWS FCE, and the results were classified as either consistent or inconsistent. Results From 11 identified studies, 150 item-specific reliability measures were extracted. 89% of the extracted inter-rater reliability measures, all of the intra-rater reliability measures and 96% of the test-retest reliability measures of the weight handling and strength tests had an acceptable level of reliability, compared to only 67% of the test-retest reliability measures of the posture/mobility tests and 56% of the test-retest reliability measures of the locomotion tests. Both of the extracted test-retest reliability measures of the balance test were acceptable. Conclusions Weight handling and strength tests were found to have consistently acceptable reliability. Further research is needed to explore the reliability of the other tests as inconsistent findings or a lack of data prevented definitive conclusions. PMID:24674029

  12. Test-retest reliability of Physical Activity Neighborhood Environment Scale among urban men and women in Nanjing, China.

    Science.gov (United States)

    Zhao, L; Wang, Z; Qin, Z; Leslie, E; He, J; Xiong, Y; Xu, F

    2018-03-01

    The identification of physical-activity-friendly built environment (BE) constructs is highly useful for physical activity promotion and maintenance. The Physical Activity Neighborhood Environment Scale (PANES) was developed for assessing BE correlates. However, PANES reliability has not been investigated among adults in China. A cross-sectional study. With multistage sampling approaches, 1568 urban adults (aged 35-74 years) were recruited for the initial survey on all 17 items of PANES Chinese version (PANES-CHN), with the survey repeated 7 days later for each participant. Intraclass correlation coefficient (ICC) was used to assess the test-retest reliability of PANES-CHN for each item. Totally, 1551 participants completed both surveys (follow-up rate = 98.9%). Among participants (mean age: 54.7 ± 11.1 years), 47.8% were men, 22.1% were elders, and 22.7% had ≥13 years of education. Overall, the PANES-CHN demonstrated at least substantial reliability with ICCs ranging from 0.66 to 0.95 (core items), from 0.75 to 0.95 (recommended items), and from 0.78 to 0.87 (optional items). Similar outcomes were observed when data were analyzed by gender or age groups. The PANES-CHN has excellent test-retest reliability and thus has valuable utility for assessing urban BE attributes among Chinese adults. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  13. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    Science.gov (United States)

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  14. Inter-rater and test-retest reliability of quality assessments by novice student raters using the Jadad and Newcastle-Ottawa Scales.

    Science.gov (United States)

    Oremus, Mark; Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C

    2012-01-01

    Quality assessment of included studies is an important component of systematic reviews. The authors investigated inter-rater and test-retest reliability for quality assessments conducted by inexperienced student raters. Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle-Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13-20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. McMaster Integrative Neuroscience Discovery and Study Program. 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test-retest reliability using ICC(2,1). Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI -0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were -0.14 (95% CI -0.28 to 0.00) to 0.39 (95% CI -0.02 to 0.81) for the NOS cohort and -0.20 (95% CI -0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case-control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test-retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were -0.19 (95% CI -0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case-control, the ICC(2,1)s were 0.46 (95% CI -0.13 to 0.92) and 0.83 (95% CI 0.48 to 0.95). Inter-rater reliability was generally poor

  15. Interrater and test-retest reliability and validity of the Norwegian version of the BESTest and mini-BESTest in people with increased risk of falling.

    Science.gov (United States)

    Hamre, Charlotta; Botolfsen, Pernille; Tangen, Gro Gujord; Helbostad, Jorunn L

    2017-04-20

    The Balance Evaluation Systems Test (BESTest) was developed to assess underlying systems for balance control in order to be able to individually tailor rehabilitation interventions to people with balance disorders. A short form, the Mini-BESTest, was developed as a screening test. The study aimed to assess interrater and test-retest reliability of the Norwegian version of the BESTest and the Mini-BESTest in community-dwelling people with increased risk of falling and to assess concurrent validity with the Fall Efficacy Scale-International (FES-I), and it was an observational study with a cross-sectional design. Forty-two persons with increased risk of falling (elderly over 65 years of age, persons with a history of stroke or Multiple Sclerosis) were assessed twice by two raters. Relative reliability was analysed with Intraclass Correlation Coefficient (ICC), and absolute reliability with standard error of measurement (SEM) and smallest detectable change (SDC). Concurrent validity was assessed against the FES-I using Spearman's rho. The BESTest showed very good interrater reliability (ICC = 0.98, SEM = 1.79, SDC 95  = 5.0) and test-retest reliability (rater A/rater B = ICC = 0.89/0.89, SEM = 3.9/4.3, SDC 95  = 10.8/11.8). The Mini-BESTest also showed very good interrater reliability (ICC = 0.95, SEM = 1.19, SDC 95  = 3.3) and test-retest reliability (rater A/rater B = ICC = 0.85/0.84, SEM = 1.8/1.9, SDC 95  = 4.9/5.2). The correlations were moderate between the FES-I and both the BESTest and the Mini-BESTest (Spearman's rho -0.51 and-0.50, p test-retest reliability when assessed in a heterogeneous sample of people with increased risk of falling. The concurrent validity measured against the FES-I showed moderate correlation. The results are comparable with earlier studies and indicate that the Norwegian versions can be used in daily clinic and in research.

  16. Test-retest reliability and factor structures of organizational citizenship behavior for Hong Kong workers.

    Science.gov (United States)

    Lam, S S

    2001-02-01

    In 1990 Podsakoff, MacKenzie, Moorman, and Fetter developed a scale to measure the five dimensions of organizational citizenship behavior. Test-retest data over 15 weeks are reported for this scale for a sample of 82 female and 32 male Chinese tellers (ages 18 to 54 years) from a large international bank in Hong Kong. Stability was .83, and there was no significant change between Times 1 and 2. Analysis indicated the five-factor structure and showed it to be a reliable measure when used with a nonwestern sample.

  17. Test-Retest Reliability of fMRI During Nonverbal Semantic Decisions in Moderate-Severe Nonfluent Aphasia Patients

    Directory of Open Access Journals (Sweden)

    Jacquie Kurland

    2004-01-01

    Full Text Available Cortical reorganization in poststroke aphasia is not well understood. Few studies have investigated neural mechanisms underlying language recovery in severe aphasia patients, who are typically viewed as having a poor prognosis for language recovery. Although test-retest reliability is routinely demonstrated during collection of language data in single-subject aphasia research, this is rarely examined in fMRI studies investigating the underlying neural mechanisms in aphasia recovery.

  18. The test-retest reliability of anatomical co-ordinate axes definition for the quantification of lower extremity kinematics during running.

    Science.gov (United States)

    Sinclair, Jonathan; Taylor, Paul John; Greenhalgh, Andrew; Edmundson, Christopher James; Brooks, Darrell; Hobbs, Sarah Jane

    2012-12-01

    Three-dimensional (3-D) kinematic analyses are used widely in both sport and clinical examinations. However, this procedure depends on reliable palpation of anatomical landmarks and mal-positioning of markers between sessions may result in improperly defined segment co-ordinate system axes which will produce in-consistent joint rotations. This had led some to question the efficacy of this technique. The aim of the current investigation was to assess the reliability of the anatomical frame definition when quantifying 3-D kinematics of the lower extremities during running. Ten participants completed five successful running trials at 4.0 m·s(-1) ± 5%. 3-D angular joint kinematics parameters from the hip, knee and ankle were collected using an eight camera motion analysis system. Two static calibration trials were captured. The first (test) was conducted prior to the running trials following which anatomical landmarks were removed. The second was obtained following completion of the running trials where anatomical landmarks were re-positioned (retest). Paired samples t-tests were used to compare 3-D kinematic parameters quantified using the two static trials, and intraclass correlations were employed to examine the similarities between the sagittal, coronal and transverse plane waveforms. The results indicate that no significant (p>0.05) differences were found between test and retest 3-D kinematic parameters and strong (R(2)≥0.87) correlations were observed between test and retest waveforms. Based on the results obtained from this investigation, it appears that the anatomical co-ordinate axes of the lower extremities can be defined reliably thus confirming the efficacy of studies using this technique.

  19. Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players.

    Science.gov (United States)

    Kea, J; Kramer, J; Forwell, L; Birmingham, T

    2001-08-01

    Single group, test-retest. To determine: (1) hip abduction and adduction torques during concentric and eccentric muscle actions, (2) medial and lateral one-leg hop distances, (3) the test-retest reliability of these measurements, and (4) the relationship between isokinetic measures of hip muscle strength and hop distances in elite ice hockey players. The skating motion used in ice hockey requires strong contractions of the hip and knee musculature. However, baseline scores for hip strength and hop distances, their test-retest reliability, and measures of the extent to which these tests are related for this population are not available. The dominant leg of 27 men (mean age 20 +/- 3 yrs) was tested on 2 occasions. Hip abduction and adduction movements were completed at 60 degrees.s(-1) angular velocity, with the subject lying on the non-test side and the test leg moving vertically in the subject's coronal plane. One-leg hops requiring jumping from and landing on the same leg without losing balance were completed in the medial and lateral directions. Hip adduction torques were significantly greater than abduction torques during both concentric and eccentric muscle actions, while no significant difference was observed between medial and lateral hop distances. Although hop test scores produced excellent ICCs (> 0.75) when determined using scores on 1 occasion, torques needed to be averaged over 2 test occasions to reach this level. Correlations between the strength and hop tests ranged from slight to low (r = -0.26 to 0.27) and were characterized by wide 95% confidence intervals (-0.54 to 0.61). Isokinetic tests of hip abduction and adduction did not provide a strong indication of performance during sideways hop tests. Although isokinetic tests can provide a measure of muscular strength under specific test conditions, they should not be relied upon as a primary indicator of functional abilities or readiness to return to activity.

  20. Test-retest reliability of speech-evoked auditory brainstem response in healthy children at a low sensation level.

    Science.gov (United States)

    Zakaria, Mohd Normani; Jalaei, Bahram

    2017-11-01

    Auditory brainstem responses evoked by complex stimuli such as speech syllables have been studied in normal subjects and subjects with compromised auditory functions. The stability of speech-evoked auditory brainstem response (speech-ABR) when tested over time has been reported but the literature is limited. The present study was carried out to determine the test-retest reliability of speech-ABR in healthy children at a low sensation level. Seventeen healthy children (6 boys, 11 girls) aged from 5 to 9 years (mean = 6.8 ± 3.3 years) were tested in two sessions separated by a 3-month period. The stimulus used was a 40-ms syllable /da/ presented at 30 dB sensation level. As revealed by pair t-test and intra-class correlation (ICC) analyses, peak latencies, peak amplitudes and composite onset measures of speech-ABR were found to be highly replicable. Compared to other parameters, higher ICC values were noted for peak latencies of speech-ABR. The present study was the first to report the test-retest reliability of speech-ABR recorded at low stimulation levels in healthy children. Due to its good stability, it can be used as an objective indicator for assessing the effectiveness of auditory rehabilitation in hearing-impaired children in future studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The interrater and test-retest reliability of the Home Falls and Accidents Screening Tool (HOME FAST) in Malaysia: Using raters with a range of professional backgrounds.

    Science.gov (United States)

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy

    2017-06-01

    Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context. A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur. Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters. The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls. © 2017 John Wiley & Sons, Ltd.

  2. Internal consistency, reliability, and temporal stability of the Oxford Happiness Questionnaire short-form: Test-retest data over two weeks

    OpenAIRE

    MCGUCKIN, CONOR

    2006-01-01

    PUBLISHED The Oxford Happiness Questionnaire short-form is a recently developed eight-item measure of happiness. This study evaluated the internal consistency reliability and test-retest reliability of the Oxford Happiness Questionnaire short-form among 55 Northern Irish undergraduate university students who completed the measure on two occasions separated by two weeks. Internal consistency of the measure on both occasions was satisfactory at both Time 1 (alpha = .62) and Time 2 (alpha = ....

  3. Which is the most useful patient-reported outcome in femoroacetabular impingement? Test-retest reliability of six questionnaires.

    Science.gov (United States)

    Hinman, Rana S; Dobson, Fiona; Takla, Amir; O'Donnell, John; Bennell, Kim L

    2014-03-01

    The most reliable patient-reported outcomes (PROs) for people with femoroacetabular impingement (FAI) is unknown because there have been no direct comparisons of questionnaires. Thus, the aim was to evaluate the test-retest reliability of six existing PROs in a single cohort of young active people with hip/groin pain consistent with a clinical diagnosis of FAI. Young adults with clinical FAI completed six PRO questionnaires on two occasions, 1-2 weeks apart. The PROs were modified Harris Hip Score, Hip dysfunction and Osteoarthritis Score, Hip Outcome Score, Non-Arthritic Hip Score, International Hip Outcome Tool, Copenhagen Hip and Groin Outcome Score. 30 young adults (mean age 24 years, SD 4 years, range 18-30 years; 15 men) with stable symptoms participated. Intraclass correlation coefficient(3,1) values ranged from 0.73 to 0.93 (95% CI 0.38 to 0.98) indicating that most questionnaires reached minimal reliability benchmarks. Measurement error at the individual level was quite large for most questionnaires (minimal detectable change (MDC95) 12.4-35.6, 95% CI 8.7 to 54.0). In contrast, measurement error at the group level was quite small for most questionnaires (MDC95 2.2-7.3, 95% CI 1.6 to 11). The majority of the questionnaires were reliable and precise enough for use at the group level. Samples of only 23-30 individuals were required to achieve acceptable measurement variation at the group level. Further direct comparisons of these questionnaires are required to assess other measurement properties such as validity, responsiveness and meaningful change in young people with FAI.

  4. TEST-RETEST RELIABILITY OF HAND GRIP STRENGTH MEASUREMENT USING A JAMAR HAND DYNAMOMETER IN PATIENTS WITH ACUTE AND CHRONIC CERVICAL RADICULOPATHY

    Directory of Open Access Journals (Sweden)

    Ejazi G

    2017-12-01

    Full Text Available Background: To evaluate the test-retest reliability of Jamar hand held dynamometer for measuring handgrip strength (HGS in patients with acute and chronic cervical radiculopathy and to find out the difference in measurement of the handgrip strength between acute and chronic cervical radiculopathy. Methods: A prospective, observational and non-experimental, the comparative study design was used. A sample of 72 subjects (37 women and 35 men suffering from cervical radiculopathy were divided into two groups i.e., Group A(acute and Group B(chronic, handgrip strength was measured using Jamar hand held dynamometer on two occasions by the same rater with an interval of 7-days. Data collection was based on standard guidelines of American Society of Hand Therapists. Three gripping trials (measured in Kg with patient’s arm in standardized arm position were recorded. The data was analyzed from the mean score obtained from the sample. Result: One-way Analysis of Variance(ANOVA was used to evaluate test-retest reliability and Tukey-Kramer Multiple Comparison Test used to find the difference between handgrip strength among acute and chronic Cervical radiculopathy cases. Greater P-value (>0.05 in both testing session, as well as 95% of the confidence interval, shows the reliability of the instrument and lesser p-value (0.05 in female subjects shows no significant difference in handgrip strength between the two groups. Conclusion: Excellent test-retest reliability for hand grip strength measurement was measured in patients with acute and chronic cervical radiculopathy shows that the equipment could be used as an assessment tool for this patient and significant difference exists among male handgrip strength between acute and chronic cervical radiculopathy cases whereas no difference exists among female handgrip strength between acute and chronic cervical radiculopathy cases.

  5. Test-retest reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression--a systematic review and meta-analysis.

    Science.gov (United States)

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2015-11-01

    Schizoaffective disorder is a frequent diagnosis, and its reliability is subject to ongoing discussion. We compared the diagnostic reliability of schizoaffective disorder with its main differential diagnoses. We systematically searched Medline, Embase, and PsycInfo for all studies on the test-retest reliability of the diagnosis of schizoaffective disorder as compared with schizophrenia, bipolar disorder, and unipolar depression. We used meta-analytic methods to describe and compare Cohen's kappa as well as positive and negative agreement. In addition, multiple pre-specified and post hoc subgroup and sensitivity analyses were carried out. Out of 4,415 studies screened, 49 studies were included. Test-retest reliability of schizoaffective disorder was consistently lower than that of schizophrenia (in 39 out of 42 studies), bipolar disorder (27/33), and unipolar depression (29/35). The mean difference in kappa between schizoaffective disorder and the other diagnoses was approximately 0.2, and mean Cohen's kappa for schizoaffective disorder was 0.50 (95% confidence interval: 0.40-0.59). While findings were unequivocal and homogeneous for schizoaffective disorder's diagnostic reliability relative to its three main differential diagnoses (dichotomous: smaller versus larger), heterogeneity was substantial for continuous measures, even after subgroup and sensitivity analyses. In clinical practice and research, schizoaffective disorder's comparatively low diagnostic reliability should lead to increased efforts to correctly diagnose the disorder. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. The Unsupported Upper Limb Exercise Test in People Without Disabilities: Assessing the Within-Day Test-Retest Reliability and the Effects of Age and Gender.

    Science.gov (United States)

    Oliveira, Ana; Cruz, Joana; Jácome, Cristina; Marques, Alda

    2018-01-01

    Purpose: To estimate the within-day test-retest reliability and standard error of measurement (SEM) of the unsupported upper limb exercise test (UULEX) in adults without disabilities and to determine the effects of age and gender on performance of the UULEX. Method: A cross-sectional study was conducted with 100 adults without disabilities (44 men, mean age 44.2 [SD 26] y; 56 women, mean age 38.1 [SD 24.1] y). Participants performed three UULEX tests to establish within-day reliability, measured using an intra-class correlation coefficient (ICC) model 2 (two-way random effects) with a single rater (ICC[2,1]) and SEM. The effects of age and gender were examined using two-factor mixed-design analysis of variance (ANOVA) and one-way repeated-measures ANOVA. For analysis purposes, four sub-groups were created: younger adults, older adults, men, and women. Results: Excellent within-day reliability and a small SEM were found in the four sub-groups (younger adults: ICC[2,1]=0.88; 95% CI: 0.82, 0.92; SEM∼40 s; older adults: ICC[2,1]=0.82; 95% CI: 0.72, 0.90; SEM∼50 s; men: ICC[2,1]=0.93; 95% CI: 0.88, 0.96; SEM∼30 s; women: ICC[2,1]=0.85; 95% CI: 0.78, 0.91; SEM∼45 s). Younger adults took, on average, 308.24 seconds longer than older adults to perform the test; older adults performed significantly better on the third test ( p 0.05). Conclusion: The within-day test-retest reliability and SEM values of the UULEX may be used to define the magnitude of the error obtained with repeated measures. One UULEX test seems to be adequate for younger adults to achieve reliable results, whereas three tests seem to be needed for older adults.

  7. Reliability of two social cognition tests: The combined stories test and the social knowledge test.

    Science.gov (United States)

    Thibaudeau, Élisabeth; Cellard, Caroline; Legendre, Maxime; Villeneuve, Karèle; Achim, Amélie M

    2018-04-01

    Deficits in social cognition are common in psychiatric disorders. Validated social cognition measures with good psychometric properties are necessary to assess and target social cognitive deficits. Two recent social cognition tests, the Combined Stories Test (COST) and the Social Knowledge Test (SKT), respectively assess theory of mind and social knowledge. Previous studies have shown good psychometric properties for these tests, but the test-retest reliability has never been documented. The aim of this study was to evaluate the test-retest reliability and the inter-rater reliability of the COST and the SKT. The COST and the SKT were administered twice to a group of forty-two healthy adults, with a delay of approximately four weeks between the assessments. Excellent test-retest reliability was observed for the COST, and a good test-retest reliability was observed for the SKT. There was no evidence of practice effect. Furthermore, an excellent inter-rater reliability was observed for both tests. This study shows a good reliability of the COST and the SKT that adds to the good validity previously reported for these two tests. These good psychometrics properties thus support that the COST and the SKT are adequate measures for the assessment of social cognition. Copyright © 2018. Published by Elsevier B.V.

  8. The Dichotic Digits difference Test (DDdT): Development, Normative Data, and Test-Retest Reliability Studies Part 1.

    Science.gov (United States)

    Cameron, Sharon; Glyde, Helen; Dillon, Harvey; Whitfield, Jessica; Seymour, John

    2016-06-01

    The dichotic digits test is one of the most widely used assessment tools for central auditory processing disorder. However, questions remain concerning the impact of cognitive factors on test results. To develop the Dichotic Digits difference Test (DDdT), an assessment tool that could differentiate children with cognitive deficits from children with genuine dichotic deficits based on differential test results. The DDdT consists of four subtests: dichotic free recall (FR), dichotic directed left ear (DLE), dichotic directed right ear (DRE), and diotic. Scores for six conditions are calculated (FR left ear [LE], FR right ear [RE], and FR total, as well as DLE, DRE, and diotic). Scores for four difference measures are also calculated: dichotic advantage, right-ear advantage (REA) FR, REA directed, and attention advantage. Experiment 1 involved development of the DDdT, including error rate analysis. Experiment 2 involved collection of normative and test-retest reliability data. Twenty adults (aged 25 yr 10 mo to 50 yr 7 mo, mean 36 yr 4 mo) took part in the development study; 62 normal-hearing, typically developing, primary-school children (aged 7 yr 1 mo to 11 yr 11 mo, mean 9 yr 4 mo) and 10 adults (aged 25 yr 0 mo to 51 yr 6 mo, mean 34 yr 10 mo) took part in the normative and test-retest reliability study. In Experiment 1, error rate analysis was conducted on the 36 digit-pair combinations of the DDdT. Normative data collected in Experiment 2 were arcsine transformed to achieve a distribution that was closer to a normal distribution and z-scores calculated. Pearson product-moment correlations were used to determine the strength of relationships between DDdT conditions. The development study revealed no significant differences in the adult population between test and retest on any DDdT condition. Error rates on 36 digit pairs ranged from 1.5% to 16.7%. The most and the least error-prone digits were removed before commencement of the normative data study, leaving 25

  9. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Segal, Neil A. [University of Kansas Medical Center, Department of Rehabilitation Medicine, 3901 Rainbow Boulevard, Mailstop 1046, Kansas City, KS (United States); The University of Iowa, Iowa City, IA (United States); Bergin, John; Kern, Andrew; Findlay, Christian [The University of Iowa, Iowa City, IA (United States); Anderson, Donald D. [The University of Iowa, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States)

    2017-02-15

    To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging. This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m{sup 2}; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20 fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW <10 mm. The summary measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility. The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds. The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA. (orig.)

  10. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner

    International Nuclear Information System (INIS)

    Segal, Neil A.; Bergin, John; Kern, Andrew; Findlay, Christian; Anderson, Donald D.

    2017-01-01

    To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging. This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m 2 ; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20 fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW <10 mm. The summary measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility. The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds. The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA. (orig.)

  11. Internal Consistency, Retest Reliability, and their Implications For Personality Scale Validity

    Science.gov (United States)

    McCrae, Robert R.; Kurtz, John E.; Yamagata, Shinji; Terracciano, Antonio

    2010-01-01

    We examined data (N = 34,108) on the differential reliability and validity of facet scales from the NEO Inventories. We evaluated the extent to which (a) psychometric properties of facet scales are generalizable across ages, cultures, and methods of measurement; and (b) validity criteria are associated with different forms of reliability. Composite estimates of facet scale stability, heritability, and cross-observer validity were broadly generalizable. Two estimates of retest reliability were independent predictors of the three validity criteria; none of three estimates of internal consistency was. Available evidence suggests the same pattern of results for other personality inventories. Internal consistency of scales can be useful as a check on data quality, but appears to be of limited utility for evaluating the potential validity of developed scales, and it should not be used as a substitute for retest reliability. Further research on the nature and determinants of retest reliability is needed. PMID:20435807

  12. Test-retest reliability and construct validity of the ENERGY-parent questionnaire on parenting practices, energy balance-related behaviours and their potential behavioural determinants: the ENERGY-project

    Directory of Open Access Journals (Sweden)

    Singh Amika S

    2012-08-01

    Full Text Available Abstract Background Insight in parental energy balance-related behaviours, their determinants and parenting practices are important to inform childhood obesity prevention. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. The objective of the current study was to examine the test-retest reliability and construct validity of the parent questionnaire used in the ENERGY-project, assessing parental energy balance-related behaviours, their determinants, and parenting practices among parents of 10–12 year old children. Findings We collected data among parents (n = 316 in the test-retest reliability study; n = 109 in the construct validity study of 10–12 year-old children in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent interview was assessed using ICC and percentage agreement. All but one item showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Construct validity appeared to be good to excellent for 92 out of 121 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 29 items, construct validity was moderate for 24 and poor for 5 items. Conclusions The reliability and construct validity of the items of the ENERGY-parent questionnaire on multiple energy balance-related behaviours, their potential determinants, and parenting practices appears to be good. Based on the results of the validity study, we strongly recommend adapting parts of the ENERGY-parent questionnaire if used in future research.

  13. Test-retest and interobserver reliability of quantitative sensory testing according to the protocol of the German Research Network on Neuropathic Pain (DFNS): a multi-centre study.

    Science.gov (United States)

    Geber, Christian; Klein, Thomas; Azad, Shahnaz; Birklein, Frank; Gierthmühlen, Janne; Huge, Volker; Lauchart, Meike; Nitzsche, Dorothee; Stengel, Maike; Valet, Michael; Baron, Ralf; Maier, Christoph; Tölle, Thomas; Treede, Rolf-Detlef

    2011-03-01

    Quantitative sensory testing (QST) is an instrument to assess positive and negative sensory signs, helping to identify mechanisms underlying pathologic pain conditions. In this study, we evaluated the test-retest reliability (TR-R) and the interobserver reliability (IO-R) of QST in patients with sensory disturbances of different etiologies. In 4 centres, 60 patients (37 male and 23 female, 56.4±1.9years) with lesions or diseases of the somatosensory system were included. QST comprised 13 parameters including detection and pain thresholds for thermal and mechanical stimuli. QST was performed in the clinically most affected test area and a less or unaffected control area in a morning and an afternoon session on 2 consecutive days by examiner pairs (4 QSTs/patient). For both, TR-R and IO-R, there were high correlations (r=0.80-0.93) at the affected test area, except for wind-up ratio (TR-R: r=0.67; IO-R: r=0.56) and paradoxical heat sensations (TR-R: r=0.35; IO-R: r=0.44). Mean IO-R (r=0.83, 31% unexplained variance) was slightly lower than TR-R (r=0.86, 26% unexplained variance, Ptest area (TR-R: r=0.86; IO-R: r=0.83) than in the control area (TR-R: r=0.79; IO-R: r=0.71, each Preliability of QST. We conclude that standardized QST performed by trained examiners is a valuable diagnostic instrument with good test-retest and interobserver reliability within 2days. With standardized training, observer bias is much lower than random variance. Quantitative sensory testing performed by trained examiners is a valuable diagnostic instrument with good interobserver and test-retest reliability for use in patients with sensory disturbances of different etiologies to help identify mechanisms of neuropathic and non-neuropathic pain. Copyright © 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  14. Quantitative and Qualitative Responses to Topical Cold in Healthy Caucasians Show Variance between Individuals but High Test-Retest Reliability.

    Directory of Open Access Journals (Sweden)

    Penny Moss

    Full Text Available Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot. Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%. Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56 years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%. Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add

  15. Quantitative and Qualitative Responses to Topical Cold in Healthy Caucasians Show Variance between Individuals but High Test-Retest Reliability.

    Science.gov (United States)

    Moss, Penny; Whitnell, Jasmine; Wright, Anthony

    2016-01-01

    Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot). Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%). Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56) years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%). Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add validity and

  16. Impact of Alzheimer's Disease on Caregiver Questionnaire: internal consistency, convergent validity, and test-retest reliability of a new measure for assessing caregiver burden.

    Science.gov (United States)

    Cole, Jason C; Ito, Diane; Chen, Yaozhu J; Cheng, Rebecca; Bolognese, Jennifer; Li-McLeod, Josephine

    2014-09-04

    There is a lack of validated instruments to measure the level of burden of Alzheimer's disease (AD) on caregivers. The Impact of Alzheimer's Disease on Caregiver Questionnaire (IADCQ) is a 12-item instrument with a seven-day recall period that measures AD caregiver's burden across emotional, physical, social, financial, sleep, and time aspects. Primary objectives of this study were to evaluate psychometric properties of IADCQ administered on the Web and to determine most appropriate scoring algorithm. A national sample of 200 unpaid AD caregivers participated in this study by completing the Web-based version of IADCQ and Short Form-12 Health Survey Version 2 (SF-12v2™). The SF-12v2 was used to measure convergent validity of IADCQ scores and to provide an understanding of the overall health-related quality of life of sampled AD caregivers. The IADCQ survey was also completed four weeks later by a randomly selected subgroup of 50 participants to assess test-retest reliability. Confirmatory factor analysis (CFA) was implemented to test the dimensionality of the IADCQ items. Classical item-level and scale-level psychometric analyses were conducted to estimate psychometric characteristics of the instrument. Test-retest reliability was performed to evaluate the instrument's stability and consistency over time. Virtually none (2%) of the respondents had either floor or ceiling effects, indicating the IADCQ covers an ideal range of burden. A single-factor model obtained appropriate goodness of fit and provided evidence that a simple sum score of the 12 items of IADCQ can be used to measure AD caregiver's burden. Scales-level reliability was supported with a coefficient alpha of 0.93 and an intra-class correlation coefficient (for test-retest reliability) of 0.68 (95% CI: 0.50-0.80). Low-moderate negative correlations were observed between the IADCQ and scales of the SF-12v2. The study findings suggest the IADCQ has appropriate psychometric characteristics as a

  17. Test-retest reliability and agreement of the Satisfaction with the Assistive Technology Services (SATS) instrument in two Nordic countries.

    Science.gov (United States)

    Sund, Terje; Iwarsson, Susanne; Anttila, Heidi; Helle, Tina; Brandt, Ase

    2014-07-01

    The purpose of this study was to investigate test-retest reliability, agreement, internal consistency, and floor- and ceiling effects of the Danish and Finnish versions of the Satisfaction with the Assistive Technology Services (SATS) instrument among adult users of powered wheelchairs (PWCs) or powered scooters (scooters). Test-retest design, two telephone interviews 7-18 days apart of 40 informants, with mean age of 67.5 (SD 13.09) years in the Danish; and 54 informants with mean age of 55.6 (SD 12.09) years in the Finnish sample. The intra-class correlation coefficient varied between 0.57 and 0.93 for items in the Danish and between 0.41 and 0.93 in the Finnish sample. The percentage agreement varied between 54.2 and 79.5 for items in the Danish and between 69.2 and 81.1 in the Finnish sample, while the Cronbach's alpha values varied between 0.87 and 0.96 in the two samples. A ceiling effect was found in all items of both samples. This study indicates that the SATS may be reliably administered for telephone interviews among adult PWC and scooter users, and give information about aspects of the service delivery process for quality development improvement purposes. Further psychometric testing of the SATS is required.

  18. Test-Retest Reliability of Measurements of Hand-Grip Strength Obtained by Dynamometry from Older Adults: A Systematic Review of Research in the PubMed Database.

    Science.gov (United States)

    Bohannon, R W

    2017-01-01

    A systematic review was performed to summarize literature describing the test-retest reliability of grip strength measures obtained from older adults. Relevant literature was identified via a PubMed search. Seventeen articles were deemed appropriate based on inclusion and exclusion criteria. The relative test-retest reliability of grip strength measures obtained by dynamometry was good to excellent (intra-class correlation coefficients > 0.80) in all but 3 studies, which involved older adults with severe dementia. Absolute reliability, as indicated by summary statistics such as the minimum detectable change (95%), was more variable. As a percentage, that change ranged from 14.5% to 98.5%. Consequently, clinicians can be confident in the relative reliability of grip strength measures obtained from at risk older adults. However, relatively large percentage changes in grip strength may be necessary to conclude with confidence that a real change has occurred over time in some populations.

  19. Multilevel Factor Structure, Concurrent Validity, and Test-Retest Reliability of the High School Teacher Version of the Authoritative School Climate Survey

    Science.gov (United States)

    Huang, Francis L.; Cornell, Dewey G.

    2016-01-01

    Although school climate has long been recognized as an important factor in the school improvement process, there are few psychometrically supported measures based on teacher perspectives. The current study replicated and extended the factor structure, concurrent validity, and test-retest reliability of the teacher version of the Authoritative…

  20. Investigating univariate temporal patterns for intrinsic connectivity networks based on complexity and low-frequency oscillation: a test-retest reliability study.

    Science.gov (United States)

    Wang, X; Jiao, Y; Tang, T; Wang, H; Lu, Z

    2013-12-19

    Intrinsic connectivity networks (ICNs) are composed of spatial components and time courses. The spatial components of ICNs were discovered with moderate-to-high reliability. So far as we know, few studies focused on the reliability of the temporal patterns for ICNs based their individual time courses. The goals of this study were twofold: to investigate the test-retest reliability of temporal patterns for ICNs, and to analyze these informative univariate metrics. Additionally, a correlation analysis was performed to enhance interpretability. Our study included three datasets: (a) short- and long-term scans, (b) multi-band echo-planar imaging (mEPI), and (c) eyes open or closed. Using dual regression, we obtained the time courses of ICNs for each subject. To produce temporal patterns for ICNs, we applied two categories of univariate metrics: network-wise complexity and network-wise low-frequency oscillation. Furthermore, we validated the test-retest reliability for each metric. The network-wise temporal patterns for most ICNs (especially for default mode network, DMN) exhibited moderate-to-high reliability and reproducibility under different scan conditions. Network-wise complexity for DMN exhibited fair reliability (ICC<0.5) based on eyes-closed sessions. Specially, our results supported that mEPI could be a useful method with high reliability and reproducibility. In addition, these temporal patterns were with physiological meanings, and certain temporal patterns were correlated to the node strength of the corresponding ICN. Overall, network-wise temporal patterns of ICNs were reliable and informative and could be complementary to spatial patterns of ICNs for further study. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  1. Short-interval test-retest interrater reliability of the Dutch version of the structured clinical interview for DSM-IV personality disorders (SCID-II)

    NARCIS (Netherlands)

    Weertman, A; ArntZ, A; Dreessen, L; van Velzen, C; Vertommen, S

    2003-01-01

    This study examined the short-interval test-retest reliability of the Structured Clinical Interview (SCID-II: First, Spitzer, Gibbon, & Williams, 1995) for DSM-IV personality disorders (PDs). The SCID-II was administered to 69 in- and outpatients on two occasions separated by 1 to 6 weeks. The

  2. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  3. Research Review: Test-retest reliability of standardized diagnostic interviews to assess child and adolescent psychiatric disorders: a systematic review and meta-analysis.

    Science.gov (United States)

    Duncan, Laura; Comeau, Jinette; Wang, Li; Vitoroulis, Irene; Boyle, Michael H; Bennett, Kathryn

    2018-02-19

    A better understanding of factors contributing to the observed variability in estimates of test-retest reliability in published studies on standardized diagnostic interviews (SDI) is needed. The objectives of this systematic review and meta-analysis were to estimate the pooled test-retest reliability for parent and youth assessments of seven common disorders, and to examine sources of between-study heterogeneity in reliability. Following a systematic review of the literature, multilevel random effects meta-analyses were used to analyse 202 reliability estimates (Cohen's kappa = ҡ) from 31 eligible studies and 5,369 assessments of 3,344 children and youth. Pooled reliability was moderate at ҡ = .58 (CI 95% 0.53-0.63) and between-study heterogeneity was substantial (Q = 2,063 (df = 201), p reliability varied across informants for specific types of psychiatric disorder (ҡ = .53-.69 for parent vs. ҡ = .39-.68 for youth) with estimates significantly higher for parents on attention deficit hyperactivity disorder, oppositional defiant disorder and the broad groupings of externalizing and any disorder. Reliability was also significantly higher in studies with indicators of poor or fair study methodology quality (sample size reliability of SDIs and the usefulness of these tools in both clinical and research contexts. Potential remedies include the introduction of standardized study and reporting requirements for reliability studies, and exploration of other approaches to assessing and classifying child and adolescent psychiatric disorder. © 2018 Association for Child and Adolescent Mental Health.

  4. Test-Retest Reliability and Minimal Detectable Change of Randomized Dichotic Digits in Learning-Disabled Children: Implications for Dichotic Listening Training.

    Science.gov (United States)

    Mahdavi, Mohammad Ebrahim; Pourbakht, Akram; Parand, Akram; Jalaie, Shohreh

    2018-03-01

    Evaluation of dichotic listening to digits is a common part of many studies for diagnosis and managing auditory processing disorders in children. Previous researchers have verified test-retest relative reliability of dichotic digits results in normal children and adults. However, detecting intervention-related changes in the ear scores after dichotic listening training requires information regarding trial-to-trial typical variation of individual ear scores that is estimated using indices of absolute reliability. Previous studies have not addressed absolute reliability of dichotic listening results. To compare the results of the Persian randomized dichotic digits test (PRDDT) and its relative and absolute indices of reliability between typical achieving (TA) and learning-disabled (LD) children. A repeated measures observational study. Fifteen LD children were recruited from a previously performed study with age range of 7-12 yr. The control group consisted of 15 TA schoolchildren with age range of 8-11 yr. The Persian randomized dichotic digits test was administered on the children under free recall condition in two test sessions 7-12 days apart. We compared the average of the ear scores and ear advantage between TA and LD children. Relative indices of reliability included Pearson's correlation and intraclass correlation (ICC 2,1 ) coefficients and absolute reliability was evaluated by calculation of standard error of measurement (SEM) and minimal detectable change (MDC) using the raw ear scores. The Pearson correlation coefficient indicated that in both groups of children the ear scores of test and retest sessions were strongly and positively (greater than +0.8) correlated. The ear scores showed excellent ICC coefficient of consistency (0.78-0.82) and fair to excellent ICC coefficient of absolute agreement (0.62-0.74) in TA children and excellent ICC coefficients of consistency and absolute agreement in LD children (0.76-0.87). SEM and SEM% of the ear scores in TA

  5. The Adaptation of Acceptance of Couple Violence Scale into Turkish: Validity and Reliability Studies

    Directory of Open Access Journals (Sweden)

    Özcan SEZER

    2008-01-01

    Full Text Available This study investigates the validity and reliability of the Turkish adaptation ofAcceptance of Couple Violence Scale (ACVS. The data of research has been attainedfrom 474 (M =243, F=231 high school students who were attending 1st, 2nd and 3thclass and coming from middle socio-economic levels in Malatya. Acceptance of CoupleViolence Scale has 11 items, Likert type and 4 point response format. The constructvalidity of ACVS was conducted by using exploratory factor analysis and varimaxrotation. Single independent factor with the eigenvalue over 1.00 has been found. Thisfactor explained 44% of total variance. To test concurrent validity, correlations betweenscores on ACVS and Aggressiveness Questionnaire were calculated. There was asignificant relationship between scores on the two scales (r= .61. Cronbach alphacoefficient of the scale was found “.87”; test-retest correlation coefficient was “r=.80”.Item-total correlation co-efficiencies vary between “.52” and “.71”. Findings show thatACVS can be used with acceptable level of validity and reliability for high schoolstudents.

  6. Assessment of test-retest reliability and internal consistency of the Wisconsin Gait Scale in hemiparetic post-stroke patients

    Directory of Open Access Journals (Sweden)

    Guzik Agnieszka

    2016-09-01

    Full Text Available Introduction: A proper assessment of gait pattern is a significant aspect in planning the process of teaching gait in hemiparetic post-stroke patients. The Wisconsin Gait Scale (WGS is an observational tool for assessing post-stroke patients’ gait. The aim of the study was to assess test-retest reliability and internal consistency of the WGS and examine correlations between gait assessment made with the WGS and gait speed, Brunnström scale, Ashworth’s scale and the Barthel Index.

  7. The Parsing Syllable Envelopes Test for Assessment of Amplitude Modulation Discrimination Skills in Children: Development, Normative Data, and Test-Retest Reliability Studies.

    Science.gov (United States)

    Cameron, Sharon; Chong-White, Nicky; Mealings, Kiri; Beechey, Tim; Dillon, Harvey; Young, Taegan

    2018-02-01

    Intensity peaks and valleys in the acoustic signal are salient cues to syllable structure, which is accepted to be a crucial early step in phonological processing. As such, the ability to detect low-rate (envelope) modulations in signal amplitude is essential to parse an incoming speech signal into smaller phonological units. The Parsing Syllable Envelopes (ParSE) test was developed to quantify the ability of children to recognize syllable boundaries using an amplitude modulation detection paradigm. The envelope of a 750-msec steady-state /a/ vowel is modulated into two or three pseudo-syllables using notches with modulation depths varying between 0% and 100% along an 11-step continuum. In an adaptive three-alternative forced-choice procedure, the participant identified whether one, two, or three pseudo-syllables were heard. Development of the ParSE stimuli and test protocols, and collection of normative and test-retest reliability data. Eleven adults (aged 23 yr 10 mo to 50 yr 9 mo, mean 32 yr 10 mo) and 134 typically developing, primary-school children (aged 6 yr 0 mo to 12 yr 4 mo, mean 9 yr 3 mo). There were 73 males and 72 females. Data were collected using a touchscreen computer. Psychometric functions (PFs) were automatically fit to individual data by the ParSE software. Performance was related to the modulation depth at which syllables can be detected with 88% accuracy (referred to as the upper boundary of the uncertainty region [UBUR]). A shallower PF slope reflected a greater level of uncertainty. Age effects were determined based on raw scores. z Scores were calculated to account for the effect of age on performance. Outliers, and individual data for which the confidence interval of the UBUR exceeded a maximum allowable value, were removed. Nonparametric tests were used as the data were skewed toward negative performance. Across participants, the performance criterion (UBUR) was met with a median modulation depth of 42%. The effect of age on the UBUR was

  8. Test-retest reliability of the assessment of postural stability in typically developing children and in hearing impaired children.

    Science.gov (United States)

    De Kegel, A; Dhooge, I; Cambier, D; Baetens, T; Palmans, T; Van Waelvelde, H

    2011-04-01

    The purpose of this study was to establish test-retest reliability of centre of pressure (COP) measurements obtained by an AccuGait portable forceplate (ACG), mean COG sway velocity measured by a Basic Balance Master (BBM) and clinical balance tests in children with and without balance difficulties. 49 typically developing children and 23 hearing impaired children, with a higher risk for stability problems, between 6 and 12 years of age participated. Each child performed the modified Clinical Test of Sensory Interaction on Balance (mCTSIB), Unilateral Stance (US) and Tandem Stance on ACG, mCTSIB and US on BBM and clinical balance tests: one-leg standing, balance beam walking and one-leg hopping. All subjects completed 2 test sessions on 2 different days in the same week assessed by the same examiner. Among COP measurements obtained by the ACG, mean sway velocity was the most reliable parameter with all ICCs higher than 0.72. The standard deviation (SD) of sway velocity, sway area, SD of anterior-posterior and SD of medio-lateral COP data showed moderate to excellent reliability with ICCs between 0.55 and 0.96 but some caution must be taken into account in some conditions. BBM is less reliable but clinical balance tests are as reliable as ACG. Hearing impaired children exhibited better relative reliability (ICC) and comparable absolute reliability (SEM) for most balance parameters compared to typically developing children. Reliable information regarding postural stability of typically developing children and hearing impaired children may be obtained utilizing COP measurements generated by an AccuGait system and clinical balance tests. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Brain GABA Detection in vivo with the J-editing 1H MRS Technique: A Comprehensive Methodological Evaluation of Sensitivity Enhancement, Macromolecule Contamination and Test-Retest Reliability

    Science.gov (United States)

    Shungu, Dikoma C.; Mao, Xiangling; Gonzales, Robyn; Soones, Tacara N.; Dyke, Jonathan P.; van der Veen, Jan Willem; Kegeles, Lawrence S.

    2016-01-01

    Abnormalities in brain γ-aminobutyric acid (GABA) have been implicated in various neuropsychiatric and neurological disorders. However, in vivo GABA detection by proton magnetic resonance spectroscopy (1H MRS) presents significant challenges arising from low brain concentration, overlap by much stronger resonances, and contamination by mobile macromolecule (MM) signals. This study addresses these impediments to reliable brain GABA detection with the J-editing difference technique on a 3T MR system in healthy human subjects by (a) assessing the sensitivity gains attainable with an 8-channel phased-array head coil, (b) determining the magnitude and anatomic variation of the contamination of GABA by MM, and (c) estimating the test-retest reliability of measuring GABA with this method. Sensitivity gains and test-retest reliability were examined in the dorsolateral prefrontal cortex (DLPFC), while MM levels were compared across three cortical regions: the DLPFC, the medial prefrontal cortex (MPFC) and the occipital cortex (OCC). A 3-fold higher GABA detection sensitivity was attained with the 8-channel head coil compared to the standard single-channel head coil in DLPFC. Despite significant anatomic variation in GABA+MM and MM across the three brain regions (p GABA+MM was relatively stable across the three voxels, ranging from 41% to 49%, a non-significant regional variation (p = 0.58). The test-retest reliability of GABA measurement, expressed either as ratios to voxel tissue water (W) or total creatine, was found to be very high for both the single-channel coil and the 8-channel phased-array coil. For the 8-channel coil, for example, Pearson’s correlation coefficient of test vs. retest for GABA/W was 0.98 (R2 = 0.96, p = 0.0007), the percent coefficient of variation (CV) was 1.25%, and the intraclass correlation coefficient (ICC) was 0.98. Similar reliability was also found for the co-edited resonance of combined glutamate and glutamine (Glx) for both coils. PMID

  10. Test-retest reliabilty of exercise-induced hypoalgesia after aerobic exercise

    DEFF Research Database (Denmark)

    Vaegter, Henrik Bjarke; Dørge, Daniel Bandholtz; Schmidt, Kristian Sonne

    2018-01-01

    Objective: Exercise increases pressure pain thresholds (PPTs) in exercising and nonexercising muscles, known as exercise-induced hypoalgesia (EIH). No studies have investigated the test-retest reliability of change in PPTs after aerobic exercise. Primary objectives were to compare the effect...

  11. A Test-Retest Reliability Study of the Whiplash Disability Questionnaire in Patients With Acute Whiplash-Associated Disorders.

    Science.gov (United States)

    Stupar, Maja; Côté, Pierre; Beaton, Dorcas E; Boyle, Eleanor; Cassidy, J David

    2015-01-01

    The purpose of this study was to determine the test-retest reliability and the Minimal Detectable Change (MDC) of the Whiplash Disability Questionnaire (WDQ) in individuals with acute whiplash-associated disorders (WADs). We performed a test-retest reliability study. We included insurance claimants from Ontario who were at least 18 years of age, within 21 days of their motor vehicle collision and diagnosed as having acute WAD grades I to III. The WDQ, a 13-item questionnaire scored from 0 (no disability) to 130 (complete disability), was administered to all participants at baseline and by telephone 3 days later. We computed the intraclass correlation coefficient (model 2,1) and the MDC with 95% confidence intervals (CIs; MDC95). The mean (SD) age of the 66 participants was 41.6 (12.7) years and 71.2% were female. Twenty-nine percent had WAD I and 71.2% had WAD II. Time since injury ranged from 0 to 19 days. The mean (SD) baseline WDQ score was 49.3 (28.8) and 46.5 (29.8) 3 days later. The intraclass correlation coefficient for the WDQ total score was 0.89 (95% CI, 0.85-0.92) in the entire sample and 0.83 (95% CI, 0.69-0.93) for the 15 participants reporting no change in neck pain. The MDC95 of the WDQ was 21.4 (SD = 14.9) for participants reporting no change. The WDQ was reliable in individuals with acute WAD. There is 95% confidence that a change of approximately one-sixth of the total score is beyond the daily variation of a stable condition. This level of measurement error must be taken into consideration when interpreting change in WDQ scores. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  12. Automatically generated acceptance test: A software reliability experiment

    Science.gov (United States)

    Protzel, Peter W.

    1988-01-01

    This study presents results of a software reliability experiment investigating the feasibility of a new error detection method. The method can be used as an acceptance test and is solely based on empirical data about the behavior of internal states of a program. The experimental design uses the existing environment of a multi-version experiment previously conducted at the NASA Langley Research Center, in which the launch interceptor problem is used as a model. This allows the controlled experimental investigation of versions with well-known single and multiple faults, and the availability of an oracle permits the determination of the error detection performance of the test. Fault interaction phenomena are observed that have an amplifying effect on the number of error occurrences. Preliminary results indicate that all faults examined so far are detected by the acceptance test. This shows promise for further investigations, and for the employment of this test method on other applications.

  13. Using personality item characteristics to predict single-item reliability, retest reliability, and self-other agreement

    NARCIS (Netherlands)

    de Vries, Reinout Everhard; Realo, Anu; Allik, Jüri

    2016-01-01

    The use of reliability estimates is increasingly scrutinized as scholars become more aware that test–retest stability and self–other agreement provide a better approximation of the theoretical and practical usefulness of an instrument than its internal reliability. In this study, we investigate item

  14. Demonstration of the test-retest reliability and sensitivity of the Lower Limb Functional Index-10 as a measure of functional recovery post burn injury: a cross-sectional repeated measures study design.

    Science.gov (United States)

    Ryland, Margaret E; Grisbrook, Tiffany L; Wood, Fiona M; Phillips, Michael; Edgar, Dale W

    2016-01-01

    Lower limb burns can significantly delay recovery of function. Measuring lower limb functional outcomes is challenging in the unique burn patient population and necessitates the use of reliable and valid tools. The aims of this study were to examine the test-retest reliability, sensitivity, and internal consistency of Sections 1 and 3 of the Lower Limb Functional Index-10 (LLFI-10) questionnaire for measuring functional ability in patients with lower limb burns over time. Twenty-nine adult patients who had sustained a lower limb burn injury in the previous 12 months completed the test-retest procedure of the study. In addition, the minimal detectable change (MDC) was calculated for Section 1 and 3 of the LLFI-10. Section 1 is focused on the activity limitations experienced by patients with a lower limb disorder whereas Section 3 involves patients indicating their current percentage of pre-injury duties. Section 1 of the LLFI-10 demonstrated excellent test-retest reliability (intra-class correlation coefficient (ICC) 0.98, 95 % CI 0.96-0.99) whilst Section 3 demonstrated high test-retest reliability (ICC 0.88, 95 % CI 0.79-0.94). MDC scores for Sections 1 and 3 were 1.27 points and 30.22 %, respectively. Internal consistency was demonstrated with a significant negative association (r s  = -0.83) between Sections 1 and 3 of the LLFI-10 (p reliable for measuring functional ability in patients who have sustained lower limb burns in the previous 12 months, and furthermore, Section 1 is sensitive to changes in patient function over time.

  15. The Perceived Efficacy and Goal Setting System (PEGS), part II: evaluation of test-retest reliability and differences between child and parental reports in the Swedish version.

    Science.gov (United States)

    Vroland-Nordstrand, Kristina; Krumlinde-Sundholm, Lena

    2012-11-01

    to evaluate the test-retest reliability of children's perceptions of their own competence in performing daily tasks and of their choice of goals for intervention using the Swedish version of the perceived efficacy and goal setting system (PEGS). A second aim was to evaluate agreement between children's and parents' perceptions of the child's competence and choices of intervention goals. Forty-four children with disabilities and their parents completed the Swedish version of the PEGS. Thirty-six of the children completed a retest session allocated into one of two groups: (A) for evaluation of perceived competence and (B) for evaluation of choice of goals. Cohen's kappa, weighted kappa and absolute agreement were calculated. Test-retest reliability for children's perceived competence showed good agreement for the dichotomized scale of competent/non-competent performance; however, using the four-point scale the agreement varied. The children's own goals were relatively stable over time; 78% had an absolute agreement ranging from 50% to 100%. There was poor agreement between the children's and their parents' ratings. Goals identified by the children differed from those identified by their parents, with 48% of the children having no goals identical to those chosen by their parents. These results indicate that the Swedish version of the PEGS produces reliable outcomes comparable to the original version.

  16. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  17. Test-retest reliability of evoked BOLD signals from a cognitive-emotive fMRI test battery.

    Science.gov (United States)

    Plichta, Michael M; Schwarz, Adam J; Grimm, Oliver; Morgen, Katrin; Mier, Daniela; Haddad, Leila; Gerdes, Antje B M; Sauer, Carina; Tost, Heike; Esslinger, Christine; Colman, Peter; Wilson, Frederick; Kirsch, Peter; Meyer-Lindenberg, Andreas

    2012-04-15

    Even more than in cognitive research applications, moving fMRI to the clinic and the drug development process requires the generation of stable and reliable signal changes. The performance characteristics of the fMRI paradigm constrain experimental power and may require different study designs (e.g., crossover vs. parallel groups), yet fMRI reliability characteristics can be strongly dependent on the nature of the fMRI task. The present study investigated both within-subject and group-level reliability of a combined three-task fMRI battery targeting three systems of wide applicability in clinical and cognitive neuroscience: an emotional (face matching), a motivational (monetary reward anticipation) and a cognitive (n-back working memory) task. A group of 25 young, healthy volunteers were scanned twice on a 3T MRI scanner with a mean test-retest interval of 14.6 days. FMRI reliability was quantified using the intraclass correlation coefficient (ICC) applied at three different levels ranging from a global to a localized and fine spatial scale: (1) reliability of group-level activation maps over the whole brain and within targeted regions of interest (ROIs); (2) within-subject reliability of ROI-mean amplitudes and (3) within-subject reliability of individual voxels in the target ROIs. Results showed robust evoked activation of all three tasks in their respective target regions (emotional task=amygdala; motivational task=ventral striatum; cognitive task=right dorsolateral prefrontal cortex and parietal cortices) with high effect sizes (ES) of ROI-mean summary values (ES=1.11-1.44 for the faces task, 0.96-1.43 for the reward task, 0.83-2.58 for the n-back task). Reliability of group level activation was excellent for all three tasks with ICCs of 0.89-0.98 at the whole brain level and 0.66-0.97 within target ROIs. Within-subject reliability of ROI-mean amplitudes across sessions was fair to good for the reward task (ICCs=0.56-0.62) and, dependent on the particular ROI

  18. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Marianna S.; Newman, David; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Leinhard, Olof Dahlqvist [Linkoeping University, Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences, Linkoeping (Sweden); Karlsson, Anette; Borga, Magnus [Linkoeping University, Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping University, Department of Biomedical Engineering, Linkoeping (Sweden); Rosander, Johannes [Advanced MR Analytics AB, Linkoeping (Sweden); Toms, Andoni P. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Radiology Academy, Cotman Centre, Norwich, Norfolk (United Kingdom)

    2014-09-15

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19.32 L (SD9.1) and 19.28 L (SD9.12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1.0, 95 % level of agreement -0.32-0.2 L). ICC for all automated test-retest muscle volumes were almost perfect (0.99-1.0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1.68 L (2SD0.6) compared to automated 1.64 L (2SD 0.6), left lower leg: manual 1.69 L (2SD 0.64) compared to automated 1.63 L (SD0.61), correlation coefficients for automated and manual segmentation were 0.94-0.96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. (orig.)

  19. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system

    International Nuclear Information System (INIS)

    Thomas, Marianna S.; Newman, David; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N.; Leinhard, Olof Dahlqvist; Karlsson, Anette; Borga, Magnus; Rosander, Johannes; Toms, Andoni P.

    2014-01-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19.32 L (SD9.1) and 19.28 L (SD9.12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1.0, 95 % level of agreement -0.32-0.2 L). ICC for all automated test-retest muscle volumes were almost perfect (0.99-1.0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1.68 L (2SD0.6) compared to automated 1.64 L (2SD 0.6), left lower leg: manual 1.69 L (2SD 0.64) compared to automated 1.63 L (SD0.61), correlation coefficients for automated and manual segmentation were 0.94-0.96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. (orig.)

  20. Test-retest reliability of knee extensor rate of velocity and power development in older adults using the isotonic mode on a Biodex System 3 dynamometer.

    Science.gov (United States)

    Van Driessche, Stijn; Van Roie, Evelien; Vanwanseele, Benedicte; Delecluse, Christophe

    2018-01-01

    Isotonic testing and measures of rapid power production are emerging as functionally relevant test methods for detection of muscle aging. Our objective was to assess reliability of rapid velocity and power measures in older adults using the isotonic mode of an isokinetic dynamometer. Sixty-three participants (aged 65 to 82 years) underwent a test-retest protocol with one week time interval. Isotonic knee extension tests were performed at four different loads: 0%, 25%, 50% and 75% of maximal isometric strength. Peak velocity (pV) and power (pP) were determined as the highest values of the velocity and power curve. Rate of velocity (RVD) and power development (RPD) were calculated as the linear slopes of the velocity- and power-time curve. Relative and absolute measures of test-retest reliability were analyzed using intraclass correlation coefficients (ICC), standard error of measurement (SEM) and Bland-Altman analyses. Overall, reliability was high for pV, pP, RVD and RPD at 0%, 25% and 50% load (ICC: .85 - .98, SEM: 3% - 10%). A trend for increased reliability at lower loads seemed apparent. The tests at 75% load led to range of motion failure and should be avoided. In addition, results demonstrated that caution is advised when interpreting early phase results (first 50ms). To conclude, our results support the use of the isotonic mode of an isokinetic dynamometer for testing rapid power and velocity characteristics in older adults, which is of high clinical relevance given that these muscle characteristics are emerging as the primary outcomes for preventive and rehabilitative interventions in aging research.

  1. An Examination of Test-Retest, Alternate Form Reliability, and Generalizability Theory Study of the easyCBM Reading Assessments: Grade 5. Technical Report #1220

    Science.gov (United States)

    Lai, Cheng-Fei; Park, Bitnara Jasmine; Anderson, Daniel; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    This technical report is one in a series of five describing the reliability (test/retest and alternate form) and G-Theory/D-Study research on the easyCBM reading measures, grades 1-5. Data were gathered in the spring of 2011 from a convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest.…

  2. An Examination of Test-Retest, Alternate Form Reliability, and Generalizability Theory Study of the easyCBM Reading Assessments: Grade 2. Technical Report #1217

    Science.gov (United States)

    Anderson, Daniel; Lai, Cheg-Fei; Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    This technical report is one in a series of five describing the reliability (test/retest an alternate form) and G-Theory/D-Study on the easyCBM reading measures, grades 1-5. Data were gathered in the spring of 2011 from the convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest. Due to…

  3. An Examination of Test-Retest, Alternate Form Reliability, and Generalizability Theory Study of the easyCBM Reading Assessments: Grade 1. Technical Report #1216

    Science.gov (United States)

    Anderson, Daniel; Park, Jasmine, Bitnara; Lai, Cheng-Fei; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    This technical report is one in a series of five describing the reliability (test/retest/and alternate form) and G-Theory/D-Study research on the easy CBM reading measures, grades 1-5. Data were gathered in the spring 2011 from a convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest. Due…

  4. Development, content validity and test-retest reliability of the Lifelong Physical Activity Skills Battery in adolescents.

    Science.gov (United States)

    Hulteen, Ryan M; Barnett, Lisa M; Morgan, Philip J; Robinson, Leah E; Barton, Christian J; Wrotniak, Brian H; Lubans, David R

    2018-03-28

    Numerous skill batteries assess fundamental motor skill (e.g., kick, hop) competence. Few skill batteries examine lifelong physical activity skill competence (e.g., resistance training). This study aimed to develop and assess the content validity, test-retest and inter-rater reliability of the "Lifelong Physical Activity Skills Battery". Development of the skill battery occurred in three stages: i) systematic reviews of lifelong physical activity participation rates and existing motor skill assessment tools, ii) practitioner consultation and iii) research expert consultation. The final battery included eight skills: grapevine, golf swing, jog, push-up, squat, tennis forehand, upward dog and warrior I. Adolescents (28 boys, 29 girls; M = 15.8 years, SD = 0.4 years) completed the Lifelong Physical Activity Skills Battery on two occasions two weeks apart. The skill battery was highly reliable (ICC = 0.84, 95% CI = 0.72-0.90) with individual skill reliability scores ranging from moderate (warrior I; ICC = 0.56) to high (tennis forehand; ICC = 0.82). Typical error (4.0; 95% CI 3.4-5.0) and proportional bias (r = -0.21, p = .323) were low. This study has provided preliminary evidence for the content validity and reliability of the Lifelong Physical Activity Skills Battery in an adolescent population.

  5. Morpho-Functional 1H-MRI of the Lung in COPD: Short-Term Test-Retest Reliability.

    Directory of Open Access Journals (Sweden)

    Bertram J Jobst

    Full Text Available Non-invasive end-points for interventional trials and tailored treatment regimes in chronic obstructive pulmonary disease (COPD for monitoring regionally different manifestations of lung disease instead of global assessment of lung function with spirometry would be valuable. Proton nuclear magnetic resonance imaging (1H-MRI allows for a radiation-free assessment of regional structure and function. The aim of this study was to evaluate the short-term reproducibility of a comprehensive morpho-functional lung MRI protocol in COPD.20 prospectively enrolled COPD patients (GOLD I-IV underwent 1H-MRI of the lung at 1.5T on two consecutive days, including sequences for morphology, 4D contrast-enhanced perfusion, and respiratory mechanics. Image quality and COPD-related morphological and functional changes were evaluated in consensus by three chest radiologists using a dedicated MRI-based visual scoring system. Test-retest reliability was calculated per each individual lung lobe for the extent of large airway (bronchiectasis, wall thickening, mucus plugging and small airway abnormalities (tree in bud, peripheral bronchiectasis, mucus plugging, consolidations, nodules, parenchymal defects and perfusion defects. The presence of tracheal narrowing, dystelectasis, pleural effusion, pulmonary trunk ectasia, right ventricular enlargement and, finally, motion patterns of diaphragma and chest wall were addressed.Median global scores [10(Q1:8.00;Q3:16.00 vs.11(Q1:6.00;Q3:15.00] as well as category subscores were similar between both timepoints, and kappa statistics indicated "almost perfect" global agreement (ĸ = 0.86, 95%CI = 0.81-0.91. Most subscores showed at least "substantial" agreement of MRI1 and MRI2 (ĸ = 0.64-1.00, whereas the agreement for the diagnosis of dystelectasis/effusion (ĸ = 0.42, 95%CI = 0.00-0.93 was "moderate" and of tracheal abnormalities (ĸ = 0.21, 95%CI = 0.00-0.75 "fair". Most MRI acquisitions showed at least diagnostic quality at

  6. Reliability of provocative tests of motion sickness susceptibility

    Science.gov (United States)

    Calkins, D. S.; Reschke, M. F.; Kennedy, R. S.; Dunlop, W. P.

    1987-01-01

    Test-retest reliability values were derived from motion sickness susceptibility scores obtained from two successive exposures to each of three tests: (1) Coriolis sickness sensitivity test; (2) staircase velocity movement test; and (3) parabolic flight static chair test. The reliability of the three tests ranged from 0.70 to 0.88. Normalizing values from predictors with skewed distributions improved the reliability.

  7. Retest effects in working memory capacity tests: A meta-analysis.

    Science.gov (United States)

    Scharfen, Jana; Jansen, Katrin; Holling, Heinz

    2018-06-15

    The repeated administration of working memory capacity tests is common in clinical and research settings. For cognitive ability tests and different neuropsychological tests, meta-analyses have shown that they are prone to retest effects, which have to be accounted for when interpreting retest scores. Using a multilevel approach, this meta-analysis aims at showing the reproducibility of retest effects in working memory capacity tests for up to seven test administrations, and examines the impact of the length of the test-retest interval, test modality, equivalence of test forms and participant age on the size of retest effects. Furthermore, it is assessed whether the size of retest effects depends on the test paradigm. An extensive literature search revealed 234 effect sizes from 95 samples and 68 studies, in which healthy participants between 12 and 70 years repeatedly performed a working memory capacity test. Results yield a weighted average of g = 0.28 for retest effects from the first to the second test administration, and a significant increase in effect sizes was observed up to the fourth test administration. The length of the test-retest interval and publication year were found to moderate the size of retest effects. Retest effects differed between the paradigms of working memory capacity tests. These findings call for the development and use of appropriate experimental or statistical methods to address retest effects in working memory capacity tests.

  8. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    Science.gov (United States)

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  9. Test-retest reliability of the novel 5-HT1B receptor PET radioligand [11C]P943

    International Nuclear Information System (INIS)

    Saricicek, Aybala; Chen, Jason; Ruf, Barbara; Planeta, Beata; Labaree, David; Gallezot, Jean-Dominique; Huang, Yiyun; Subramanyam, Kalyani; Maloney, Kathleen; Matuskey, David; Deserno, Lorenz; Neumeister, Alexander; Krystal, John H.; Carson, Richard E.; Bhagwagar, Zubin

    2015-01-01

    [ 11 C]P943 is a novel, highly selective 5-HT 1B PET radioligand. The aim of this study was to determine the test-retest reliability of [ 11 C]P943 using two different modeling methods and to perform a power analysis with each quantification technique. Seven healthy volunteers underwent two PET scans on the same day. Regions of interest (ROIs) were the amygdala, hippocampus, pallidum, putamen, insula, frontal, anterior cingulate, parietal, temporal and occipital cortices, and cerebellum. Two multilinear radioligand quantification techniques were used to estimate binding potential: MA1, using arterial input function data, and the second version of the multilinear reference tissue model analysis (MRTM2), using the cerebellum as the reference region. Between-scan percent variability and intraclass correlation coefficients (ICC) were used to assess test-retest reliability. We also performed power analyses to determine the method that would allow the least number of subjects using within-subject or between-subject study designs. A voxel-wise ICC analysis for MRTM2 BP ND was performed for the whole brain and all the ROIs studied. Mean percent variability between two scans across regions ranged between 0.4 % and 12.4 % for MA1 BP ND , 0.5 % and 11.5 % for MA1 BP P , 16.7 % and 28.3 % for MA1 BP F , and between 0.2 % and 5.4 % for MRTM2 BP ND . The power analyses showed a greater number of subjects were required using MA1 BP F compared with other outcome measures for both within-subject and between-subject study designs. ICC values were the highest using MRTM2 BP ND and the lowest with MA1 BP F in ten ROIs. Small regions and regions with low binding had lower ICC values than large regions and regions with high binding. Reliable measures of 5-HT 1B receptor binding can be obtained using the novel PET radioligand [ 11 C]P943. Quantification of 5-HT 1B receptor binding with MRTM2 BP ND and with MA1 BP P provided the least variability and optimal power for within-subject and

  10. Validity, Reliability, and Sensitivity of a Volleyball Intermittent Endurance Test.

    Science.gov (United States)

    Rodríguez-Marroyo, Jose A; Medina-Carrillo, Javier; García-López, Juan; Morante, Juan C; Villa, José G; Foster, Carl

    2017-03-01

    To analyze the concurrent and construct validity of a volleyball intermittent endurance test (VIET). The VIET's test-retest reliability and sensitivity to assess seasonal changes was also studied. During the preseason, 71 volleyball players of different competitive levels took part in this study. All performed the VIET and a graded treadmill test with gas-exchange measurement (GXT). Thirty-one of the players performed an additional VIET to analyze the test-retest reliability. To test the VIET's sensitivity, 28 players repeated the VIET and GXT at the end of their season. Significant (P volleyball players.

  11. Temporal stability of the Francis Scale of Attitude toward Christianity short-form: test-retest data over one week.

    Science.gov (United States)

    Lewis, Christopher Alan; Cruise, Sharon Mary; McGuckin, Conor

    2005-04-01

    This study evaluated the test-retest reliability of the Francis Scale of Attitude toward Christianity short-form. 39 Northern Irish undergraduate students completed the measure on two occasions separated by one week. Stability across the two administrations was high, r = .92, and there was no significant change between Time 1(M = 25.2, SD = 5.4) and Time 2 (M = 25.7, SD = 6.2). These data support the short-term test-retest reliability of the Francis Scale of Attitude toward Christianity short-form.

  12. Test-retest reliability, smallest real difference and concurrent validity of six different balance tests on young people with mild to moderate intellectual disability.

    Science.gov (United States)

    Blomqvist, Sven; Wester, Anita; Sundelin, Gunnevi; Rehn, Börje

    2012-12-01

    Some studies have reported that people with intellectual disability may have reduced balance ability compared with the population in general. However, none of these studies involved adolescents, and the reliability and validity of balance tests in this population are not known. The purpose of this study was to examine the reliability of six different balance tests and to investigate their concurrent validity. Test-retest reliability assessment. All subjects were recruited from a special school for people with intellectual disability in Bollnäs, Sweden. Eighty-nine adolescents (35 females and 54 males) with mild to moderate intellectual disability with a mean age of 18 years (range 16 to 20 years). All subjects followed the same test protocol on two occasions within an 11-day period. Balance test performances. Intraclass correlation coefficients greater than 0.80 were achieved for four of the balance tests: Extended Timed Up and Go Test, Modified Functional Reach Test, One-leg Stance Test and Force Platform Test. The smallest real differences ranged from 12% to 40%; less than 20% is considered to be low. Concurrent validity among these balance tests varied between no and low correlation. The results indicate that these tests could be used to evaluate changes in balance ability over time in people with mild to moderate intellectual disability. The low concurrent validity illustrates the importance of knowing more about the influence of various sensory subsystems that are significant for balance among adolescents with intellectual disability. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  13. Test-Retest Reliability, Convergent Validity, and Internal Consistency of the Persian Version of Fullerton Advanced Balance Scale in Iranian Community-Dwelling Older Adults

    OpenAIRE

    Azar Sabet; Akram Azad; Ghorban Taghizadeh

    2016-01-01

    Objectives: This study was performed to evaluate convergent validity, test-retest reliability and internal consistency of the Persian translation of the Fullerton advanced balance (FAB) for use in Iranian community- dwelling older adults and improve the quality of their functional balance assessment. Methods & Materials: The original scale was translated with forward-backward protocol. In the next step, using convenience sampling and inclusion criteria, 88 functionally indep...

  14. Test-retest Reliability and Agreement of the Satisfaction with the Assistive Technology Services (SATS) Instrument in Two Nordic Countries

    DEFF Research Database (Denmark)

    Sund, Terje; Anttila, Heidi; Iwarsson, Susanne

    2014-01-01

    Purpose: The purpose of this study was to investigate test–retest reliability, agreement, internal consistency, and floor- and ceiling effects of the Danish and Finnish versions of the Satisfaction with the Assistive Technology Services (SATS) instrument among adult users of powered wheelchairs (...

  15. Reliabilities of mental rotation tasks: limits to the assessment of individual differences.

    Science.gov (United States)

    Hirschfeld, Gerrit; Thielsch, Meinald T; Zernikow, Boris

    2013-01-01

    Mental rotation tasks with objects and body parts as targets are widely used in cognitive neuropsychology. Even though these tasks are well established to study between-groups differences, the reliability on an individual level is largely unknown. We present a systematic study on the internal consistency and test-retest reliability of individual differences in mental rotation tasks comparing different target types and orders of presentations. In total n = 99 participants (n = 63 for the retest) completed the mental rotation tasks with hands, feet, faces, and cars as targets. Different target types were presented in either randomly mixed blocks or blocks of homogeneous targets. Across all target types, the consistency (split-half reliability) and stability (test-retest reliabilities) were good or acceptable both for intercepts and slopes. At the level of individual targets, only intercepts showed acceptable reliabilities. Blocked presentations resulted in significantly faster and numerically more consistent and stable responses. Mental rotation tasks-especially in blocked variants-can be used to reliably assess individual differences in global processing speed. However, the assessment of the theoretically important slope parameter for individual targets requires further adaptations to mental rotation tests.

  16. Test-retest reliability and agreement of the SPI-Questionnaire to detect symptoms of digital ischemia in elite volleyball players.

    Science.gov (United States)

    van de Pol, Daan; Zacharian, Tigran; Maas, Mario; Kuijer, P Paul F M

    2017-06-01

    The Shoulder posterior circumflex humeral artery Pathology and digital Ischemia - questionnaire (SPI-Q) has been developed to enable periodic surveillance of elite volleyball players, who are at risk for digital ischemia. Prior to implementation, assessing reliability is mandatory. Therefore, the test-retest reliability and agreement of the SPI-Q were evaluated among the population at risk. A questionnaire survey was performed with a 2-week interval among 65 elite male volleyball players assessing symptoms of cold, pale and blue digits in the dominant hand during or after practice or competition using a 4-point Likert scale (never, sometimes, often and always). Kappa (κ) and percentage of agreement (POA) were calculated for individual symptoms, and to distinguish symptomatic and asymptomatic players. For the individual symptoms, κ ranged from "poor" (0.25) to "good" (0.63), and POA ranged from "moderate" (78%) to "good" (97%). To classify symptomatic players, the SPI-Q showed "good" reliability (κ = 0.83; 95%CI 0.69-0.97) and "good" agreement (POA = 92%). The current study has proven the SPI-Q to be reliable for detecting elite male indoor volleyball players with symptoms of digital ischemia.

  17. An Examination of Test-Retest, Alternate Form Reliability, and Generalizability Theory Study of the easyCBM Passage Reading Fluency Assessments: Grade 4. Technical Report #1219

    Science.gov (United States)

    Park, Bitnara Jasmine; Anderson, Daniel; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    This technical report is one in a series of five describing the reliability (test/retest and alternate form) and G-Theory/D-Study research on the easyCBM reading measures, grades 1-5. Data were gathered in the spring of 2011 from a convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest.…

  18. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    Science.gov (United States)

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (preliability was (ICC3,3) = 0.953 (pvalidity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  19. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system.

    Science.gov (United States)

    Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P

    2014-09-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.

  20. Influences on and Limitations of Classical Test Theory Reliability Estimates.

    Science.gov (United States)

    Arnold, Margery E.

    It is incorrect to say "the test is reliable" because reliability is a function not only of the test itself, but of many factors. The present paper explains how different factors affect classical reliability estimates such as test-retest, interrater, internal consistency, and equivalent forms coefficients. Furthermore, the limits of classical test…

  1. Reliability of the Handgrip Strength Test in Elderly Subjects With Parkinson Disease.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Buraschi, Riccardo; Martinelli, Marco; Bissolotti, Luciano; Negrini, Stefano

    2016-03-01

    The handgrip strength test is widely used by clinicians; however, little has been investigated about its reliability when used in subjects with Parkinson disease (PD). The purpose of this study was to investigate the test-retest reliability of the handgrip strength test for subjects with PD. The PD group consisted of 15 patients, and the control group consisted of 15 healthy subjects. Each patient performed 3 pain-free maximal isometric contractions on each hand on 2 occasions, 1 week apart. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and 95% limits of agreement (LOA) were calculated. The 2-way analysis of variance (ANOVA) was conducted to determine the differences between sides and groups. Test-retest reliability of measurements of grip strength was excellent for dominant (ICC = 0.97; P = .001) and non-dominant (ICC = 0.98; P = .001) hand of participant with PD and (ICC = 0.99; P = .001) and (ICC = 0.99; P = .001) respectively, of healthy group. The Jamar hand dynamometer had fair to excellent test-retest reliability to test grip strength in participants with PD.

  2. [The reliability of a questionnaire regarding Colombian children's physical activity].

    Science.gov (United States)

    Herazo-Beltrán, Aliz Y; Domínguez-Anaya, Regina

    2012-10-01

    Reporting the Physical Activity Questionnaire for school children's (PAQ-C) test-retest reliability and internal consistency. This was a descriptive study of 100 school-aged children aged 9 to 11 years old attending a school in Cartagena, Colombia. The sample was randomly selected. The PAQ-C was given twice, one week apart, after the informed consent forms had been signing by the children's parents and school officials. Cronbach's alpha coefficient of reliability was used for assessing internal consistency and an intra-class correlation coefficient for test-retest reliability SPSS (version 17.0) was used for statistical analysis. The questionnaire scored 0.73 internal consistencies during the first measurement and 0.78 on the second; intra-class correlation coefficient was 0.60. There were differences between boys and girls regarding both measurements. The PAQ-C had acceptable internal consistency and test-retest reliability, thereby making it useful for measuring children's self-reported physical activity and a valuable tool for population studies in Colombia.

  3. Evaluation of the Relative Validity and Test-Retest Reliability of a 15-Item Beverage Intake Questionnaire in Children and Adolescents.

    Science.gov (United States)

    Hill, Catelyn E; MacDougall, Carly R; Riebl, Shaun K; Savla, Jyoti; Hedrick, Valisa E; Davy, Brenda M

    2017-11-01

    Added sugar intake, in the form of sugar-sweetened beverages (SSBs), may contribute to weight gain and obesity development in children and adolescents. A valid and reliable brief beverage intake assessment tool for children and adolescents could facilitate research in this area. The purpose of this investigation was to evaluate the relative validity and test-retest reliability of a 15-item beverage intake questionnaire (BEVQ) for assessing usual beverage intake in children and adolescents. This cross-sectional investigation included four study visits within a 2- to 3-week time period. Participants (333 enrolled; 98% completion rate) were children aged 6 to 11 years and adolescents aged 12 to18 years recruited from the New River Valley, VA, region from January 2014 to September 2015. Study visits included assessment of height/weight, health history, and four 24-hour dietary recalls (24HRs). The BEVQ was completed at two visits (BEVQ 1, BEVQ 2). To evaluate relative validity, BEVQ 1 was compared with habitual beverage intake determined by the averaged 24HR. To evaluate test-retest reliability, BEVQ 1 was compared with BEVQ 2. Analyses included descriptive statistics, independent sample t tests, χ 2 tests, one-way analysis of variance, paired sample t tests, and correlational analyses. In the full sample, self-reported water and total SSB intake were not different between BEVQ 1 and 24HR (mean differences 0±1 fl oz and 0±1 fl oz, respectively; both P values >0.05). Reported intake across all beverage categories was significantly correlated between BEVQ 1 and BEVQ 2 (Pbeverages was not different (all P values >0.05) between BEVQ 1 and 24HR (mean differences: whole milk=3±4 kcal, reduced-fat milk=9±5 kcal, and fat-free milk=7±6 kcal, which is 7±15 total beverage kilocalories). In adolescents (n=200), water and SSB kilocalories were not different (both P values >0.05) between BEVQ 1 and 24HR (mean differences: -1±1 fl oz and 12±9 kcal, respectively). A 15

  4. Internal consistency, test-retest reliability and measurement error of the self-report version of the social skills rating system in a sample of Australian adolescents.

    Directory of Open Access Journals (Sweden)

    Sharmila Vaz

    Full Text Available The social skills rating system (SSRS is used to assess social skills and competence in children and adolescents. While its characteristics based on United States samples (US are published, corresponding Australian figures are unavailable. Using a 4-week retest design, we examined the internal consistency, retest reliability and measurement error (ME of the SSRS secondary student form (SSF in a sample of Year 7 students (N = 187, from five randomly selected public schools in Perth, western Australia. Internal consistency (IC of the total scale and most subscale scores (except empathy on the frequency rating scale was adequate to permit independent use. On the importance rating scale, most IC estimates for girls fell below the benchmark. Test-retest estimates of the total scale and subscales were insufficient to permit reliable use. ME of the total scale score (frequency rating for boys was equivalent to the US estimate, while that for girls was lower than the US error. ME of the total scale score (importance rating was larger than the error using the frequency rating scale. The study finding supports the idea of using multiple informants (e.g. teacher and parent reports, not just student as recommended in the manual. Future research needs to substantiate the clinical meaningfulness of the MEs calculated in this study by corroborating them against the respective Minimum Clinically Important Difference (MCID.

  5. Internal consistency, test-retest reliability and measurement error of the self-report version of the social skills rating system in a sample of Australian adolescents.

    Science.gov (United States)

    Vaz, Sharmila; Parsons, Richard; Passmore, Anne Elizabeth; Andreou, Pantelis; Falkmer, Torbjörn

    2013-01-01

    The social skills rating system (SSRS) is used to assess social skills and competence in children and adolescents. While its characteristics based on United States samples (US) are published, corresponding Australian figures are unavailable. Using a 4-week retest design, we examined the internal consistency, retest reliability and measurement error (ME) of the SSRS secondary student form (SSF) in a sample of Year 7 students (N = 187), from five randomly selected public schools in Perth, western Australia. Internal consistency (IC) of the total scale and most subscale scores (except empathy) on the frequency rating scale was adequate to permit independent use. On the importance rating scale, most IC estimates for girls fell below the benchmark. Test-retest estimates of the total scale and subscales were insufficient to permit reliable use. ME of the total scale score (frequency rating) for boys was equivalent to the US estimate, while that for girls was lower than the US error. ME of the total scale score (importance rating) was larger than the error using the frequency rating scale. The study finding supports the idea of using multiple informants (e.g. teacher and parent reports), not just student as recommended in the manual. Future research needs to substantiate the clinical meaningfulness of the MEs calculated in this study by corroborating them against the respective Minimum Clinically Important Difference (MCID).

  6. Construct validity, test-retest reliability and internal consistency of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) in patients with carpal tunnel syndrome.

    Science.gov (United States)

    Buntragulpoontawee, Montana; Phutrit, Suphatha; Tongprasert, Siam; Wongpakaran, Tinakon; Khunachiva, Jeeranan

    2018-03-27

    This study evaluated additional psychometric properties of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) which included, test-retest reliability, construct validity, internal consistency of in patients with carpal tunnel syndrome. As for determining construct validity, the Thai EuroQOL questionnaire (EQ-5D-5L) was also administered in order to examine convergent and divergent validity. Fifty patients completed both questionnaires. The DASH-TH showed excellent test-retest reliability (intraclass correlation coefficient = 0.811) and internal consistency (Cronbach's alpha = 0.911). The exploratory factor analysis yielded a six-factor solution while the confirmatory factor analysis denoted that the hypothesized model adequately fit the data with a comparative fit index of 0.967 and a Tucker-Lewis index of 0.964. The related subscales between the DASH-TH and the Thai EQ-5D-5L were significantly correlated, indicating the DASH-TH's convergent and discriminant validity. The DASH-TH demonstrated good reliability, internal consistency construct validity, and multidimensionality, in assessing the upper extremity function in carpal tunnel syndrome patients.

  7. Test-retest reliability of the novel 5-HT{sub 1B} receptor PET radioligand [{sup 11}C]P943

    Energy Technology Data Exchange (ETDEWEB)

    Saricicek, Aybala [Yale University, Department of Psychiatry, New Haven, CT (United States); Connecticut Mental Health Center, Abraham Ribicoff Research Facilities, New Haven, CT (United States); Izmir Katip Celebi University, Department of Psychiatry, Izmir (Turkey); Chen, Jason; Ruf, Barbara [Yale University, Department of Psychiatry, New Haven, CT (United States); Planeta, Beata; Labaree, David; Gallezot, Jean-Dominique; Huang, Yiyun [Yale University, PET Center, Department of Diagnostic Radiology, New Haven, CT (United States); Subramanyam, Kalyani; Maloney, Kathleen [Yale University, Department of Psychiatry, New Haven, CT (United States); Connecticut Mental Health Center, Abraham Ribicoff Research Facilities, New Haven, CT (United States); Matuskey, David [Yale University, Department of Psychiatry, New Haven, CT (United States); Connecticut Mental Health Center, Abraham Ribicoff Research Facilities, New Haven, CT (United States); Yale University, PET Center, Department of Diagnostic Radiology, New Haven, CT (United States); Deserno, Lorenz [Charite - Universitaetsmedizin Berlin, Department of Psychiatry and Psychotherapy, Campus Charite Mitte, Berlin (Germany); Max-Planck-Institute for Human Cognitive and Brain Sciences, Leipzig, Berlin (Germany); Neumeister, Alexander [Yale University, Department of Psychiatry, New Haven, CT (United States); Mount Sinai School of Medicine, Department of Psychiatry, New York, NY (United States); VA Connecticut Healthcare System, Clinical Neuroscience Division, VA National Center for PTSD, West Haven, CT (United States); Krystal, John H. [Yale University, Department of Psychiatry, New Haven, CT (United States); Connecticut Mental Health Center, Abraham Ribicoff Research Facilities, New Haven, CT (United States); VA Connecticut Healthcare System, Clinical Neuroscience Division, VA National Center for PTSD, West Haven, CT (United States); Carson, Richard E. [Connecticut Mental Health Center, Abraham Ribicoff Research Facilities, New Haven, CT (United States); Bhagwagar, Zubin [Yale University, Department of Psychiatry, New Haven, CT (United States); Connecticut Mental Health Center, Abraham Ribicoff Research Facilities, New Haven, CT (United States); Bristol-Myers Squibb, Wallingford, CT (United States)

    2014-11-27

    [{sup 11}C]P943 is a novel, highly selective 5-HT{sub 1B} PET radioligand. The aim of this study was to determine the test-retest reliability of [{sup 11}C]P943 using two different modeling methods and to perform a power analysis with each quantification technique. Seven healthy volunteers underwent two PET scans on the same day. Regions of interest (ROIs) were the amygdala, hippocampus, pallidum, putamen, insula, frontal, anterior cingulate, parietal, temporal and occipital cortices, and cerebellum. Two multilinear radioligand quantification techniques were used to estimate binding potential: MA1, using arterial input function data, and the second version of the multilinear reference tissue model analysis (MRTM2), using the cerebellum as the reference region. Between-scan percent variability and intraclass correlation coefficients (ICC) were used to assess test-retest reliability. We also performed power analyses to determine the method that would allow the least number of subjects using within-subject or between-subject study designs. A voxel-wise ICC analysis for MRTM2 BP{sub ND} was performed for the whole brain and all the ROIs studied. Mean percent variability between two scans across regions ranged between 0.4 % and 12.4 % for MA1 BP{sub ND}, 0.5 % and 11.5 % for MA1 BP{sub P}, 16.7 % and 28.3 % for MA1 BP{sub F}, and between 0.2 % and 5.4 % for MRTM2 BP{sub ND}. The power analyses showed a greater number of subjects were required using MA1 BP{sub F} compared with other outcome measures for both within-subject and between-subject study designs. ICC values were the highest using MRTM2 BP{sub ND} and the lowest with MA1 BP{sub F} in ten ROIs. Small regions and regions with low binding had lower ICC values than large regions and regions with high binding. Reliable measures of 5-HT{sub 1B} receptor binding can be obtained using the novel PET radioligand [{sup 11}C]P943. Quantification of 5-HT{sub 1B} receptor binding with MRTM2 BP{sub ND} and with MA1 BP{sub P

  8. Translation, reliability, and clinical utility of the Melbourne Assessment 2.

    Science.gov (United States)

    Gerber, Corinna N; Plebani, Anael; Labruyère, Rob

    2017-10-12

    The aims were to (i) provide a German translation of the Melbourne Assessment 2 (MA2), a quantitative test to measure unilateral upper limb function in children with neurological disabilities and (ii) to evaluate its reliability and aspects of clinical utility. After its translation into German and approval of the back translation by the original authors, the MA2 was performed and videotaped twice with 30 children with neuromotor disorders. For each participant, two raters scored the video of the first test for inter-rater reliability. To determine test-retest reliability, one rater additionally scored the video of the second test while the other rater repeated the scoring of the first video to evaluate intra-rater reliability. Time needed for rater training, test administration, and scoring was recorded. The four subscale scores showed excellent intra-, inter-rater, and test-retest reliability with intraclass correlation coefficients of 0.90-1.00 (95%-confidence intervals 0.78-1.00). Score items revealed substantial to almost perfect intra-rater reliability (weighted kappa k w  = 0.66-1.00) for the more affected side. Score item inter-rater and test-retest reliability of the same extremity were, with one exception, moderate to almost perfect (k w  = 0.42-0.97; k w  = 0.40-0.89). Furthermore, the MA2 was feasible and acceptable for patients and clinicians. The MA2 showed excellent subscale and moderate to almost perfect score item reliability. Implications for Rehabilitation There is a lack of high-quality studies about psychometric properties of upper limb measurement tools in the neuropediatric population. The Melbourne Assessment 2 is a promising tool for reliable measurement of unilateral upper limb movement quality in the neuropediatric population. The Melbourne Assessment 2 is acceptable and practicable to therapists and patients for routine use in clinical care.

  9. An Examination of Test-Retest, Alternate Form Reliability, and Generalizability Theory Study of the easyCBM Word and Passage Reading Fluency Assessments: Grade 3. Technical Report #1218

    Science.gov (United States)

    Park, Bitnara Jasmine; Anderson, Daniel; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    This technical report is one in a series of five describing the reliability (test/retest and alternate form) and G-Theory/D-Study research on the easyCBM reading measures, grades 1-5. Data were gathered in the spring of 2011 from a convenience sample of students nested within classrooms at a medium-sized school district in the Pacific Northwest.…

  10. Intra and Inter-Rater Reliability of Screening for Movement Impairments: Movement Control Tests from The Foundation Matrix

    Science.gov (United States)

    Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.

    2015-01-01

    Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where

  11. Assessment of lower urinary tract symptoms in women by a self-administered questionnaire: test-retest reliability

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen; Sejr, T; Able, I

    1996-01-01

    A self-administered questionnaire assessing female lower urinary tract symptoms and their impact on quality of life is described and validated, on 56 females in six participating departments. The patients answered two identical questionnaires on separate occasions before treatment. Test-retest re...

  12. Test-retest reliability of spatial and temporal gait parameters in children with cerebral palsy as measured by an electronic walkway.

    Science.gov (United States)

    Sorsdahl, Anne Brit; Moe-Nilssen, Rolf; Strand, Liv Inger

    2008-01-01

    The purpose of this study was to examine test-retest reliability of seven selected temporal and spatial gait parameters and asymmetry measures in children with cerebral palsy. Seventeen children with CP between 3 and 13 years of age walked at three different speeds across an electronic walkway of 5.2m. The tests were repeated after approximately 25 min. The scores were normalized to a walking speed of 1.1m/s to avoid the confounding effect of gait speed on speed dependent gait parameters. Intraclass correlation coefficients (ICC(1,1) and ICC(3,1)) with 95% confidence intervals, within-subject standard deviation (S(w)) and smallest detectable difference (SDD) were calculated. The relative reliability of cadence, step length, stride length and single stance time was high to excellent (ICC(1,1) between 0.73 and 0.95), while it was poor for step width (ICC(1,1)=0.27 and 0.35). The relative reliability for two calculated asymmetry measures were high for the step length index (ICC(1,1)=0.82) and moderate for the single stance time index (ICC(1,1)=0.49). The absolute reliability values for all gait parameters are reported. Five of seven gait parameters measured by an electronic walkway and normalized to a common walking speed, appear to be highly repeatable in a short-term time span in children with CP who were able to walk without assistive walking devices, provided sufficient cognitive function.

  13. Test-retest reliability of the KINARM end-point robot for assessment of sensory, motor and neurocognitive function in young adult athletes.

    Directory of Open Access Journals (Sweden)

    Cameron S Mang

    Full Text Available Current assessment tools for sport-related concussion are limited by a reliance on subjective interpretation and patient symptom reporting. Robotic assessments may provide more objective and precise measures of neurological function than traditional clinical tests.To determine the reliability of assessments of sensory, motor and cognitive function conducted with the KINARM end-point robotic device in young adult elite athletes.Sixty-four randomly selected healthy, young adult elite athletes participated. Twenty-five individuals (25 M, mean age±SD, 20.2±2.1 years participated in a within-season study, where three assessments were conducted within a single season (assessments labeled by session: S1, S2, S3. An additional 39 individuals (28M; 22.8±6.0 years participated in a year-to-year study, where annual pre-season assessments were conducted for three consecutive seasons (assessments labeled by year: Y1, Y2, Y3. Forty-four parameters from five robotic tasks (Visually Guided Reaching, Position Matching, Object Hit, Object Hit and Avoid, and Trail Making B and overall Task Scores describing performance on each task were quantified.Test-retest reliability was determined by intra-class correlation coefficients (ICCs between the first and second, and second and third assessments. In the within-season study, ICCs were ≥0.50 for 68% of parameters between S1 and S2, 80% of parameters between S2 and S3, and for three of the five Task Scores both between S1 and S2, and S2 and S3. In the year-to-year study, ICCs were ≥0.50 for 64% of parameters between Y1 and Y2, 82% of parameters between Y2 and Y3, and for four of the five Task Scores both between Y1 and Y2, and Y2 and Y3.Overall, the results suggest moderate-to-good test-retest reliability for the majority of parameters measured by the KINARM robot in healthy young adult elite athletes. Future work will consider the potential use of this information for clinical assessment of concussion

  14. Reliability of the Timed Up and Go test and Ten-Metre Timed Walk Test in Pregnant Women with Pelvic Girdle Pain.

    Science.gov (United States)

    Evensen, Natalie M; Kvåle, Alice; Braekken, Ingeborg H

    2015-09-01

    There is a lack of functional objective tests available to measure functional status in women with pelvic girdle pain (PGP). The purpose of this study was to establish test-retest and intertester reliability of the Timed Up and Go (TUG) test and Ten-metre Timed Walk Test (10mTWT) in pregnant women with PGP. A convenience sample of women was recruited over a 4-month period and tested on two occasions, 1 week apart to determine test-retest reliability. Intertester reliability was established between two assessors at the first testing session. Subjects were instructed to undertake the TUG and 10mTWT at maximum speed. One practise trial and two timed trials for each walking test was undertaken on Day 1 and one practise trial and one timed trial on Day 2. Seventeen women with PGP aged 31.1 years (SD [standard deviation] = 2.3) and 28.7 weeks pregnant (SD = 7.4) completed gait testing. Test-retest reliability using the intraclass correlation coefficient (ICC) was excellent for the TUG (0.88) and good for the 10mTWT (0.74). Intertester reliability was determined in the first 13 participants with excellent ICC values being found for both walking tests (TUG: 0.95; 10mTWT: 0.94). This study demonstrated that the TUG and 10mTWT undertaken at fast pace are reliable, objective functional tests in pregnant women with PGP. While both tests are suitable for use in the clinical and research settings, we would recommend the TUG given the findings of higher test-retest reliability and as this test requires less space and time to set up and score. Future studies in a larger sample size are warranted to confirm the results of this study. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Validation and Test-Retest Reliability of New Thermographic Technique Called Thermovision Technique of Dry Needling for Gluteus Minimus Trigger Points in Sciatica Subjects and TrPs-Negative Healthy Volunteers

    Science.gov (United States)

    Rychlik, Michał; Samborski, Włodzimierz

    2015-01-01

    The aim of this study was to assess the validity and test-retest reliability of Thermovision Technique of Dry Needling (TTDN) for the gluteus minimus muscle. TTDN is a new thermography approach used to support trigger points (TrPs) diagnostic criteria by presence of short-term vasomotor reactions occurring in the area where TrPs refer pain. Method. Thirty chronic sciatica patients (n=15 TrP-positive and n=15 TrPs-negative) and 15 healthy volunteers were evaluated by TTDN three times during two consecutive days based on TrPs of the gluteus minimus muscle confirmed additionally by referred pain presence. TTDN employs average temperature (T avr), maximum temperature (T max), low/high isothermal-area, and autonomic referred pain phenomenon (AURP) that reflects vasodilatation/vasoconstriction. Validity and test-retest reliability were assessed concurrently. Results. Two components of TTDN validity and reliability, T avr and AURP, had almost perfect agreement according to κ (e.g., thigh: 0.880 and 0.938; calf: 0.902 and 0.956, resp.). The sensitivity for T avr, T max, AURP, and high isothermal-area was 100% for everyone, but specificity of 100% was for T avr and AURP only. Conclusion. TTDN is a valid and reliable method for T avr and AURP measurement to support TrPs diagnostic criteria for the gluteus minimus muscle when digitally evoked referred pain pattern is present. PMID:26137486

  16. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, ptest-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Relative and absolute test-retest reliabilities of pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Srimurugan Pratheep, Neeraja; Madeleine, Pascal; Arendt-Nielsen, Lars

    2018-04-25

    Pressure pain threshold (PPT) and PPT maps are commonly used to quantify and visualize mechanical pain sensitivity. Although PPT's have frequently been reported from patients with knee osteoarthritis (KOA), the absolute and relative reliability of PPT assessments remain to be determined. Thus, the purpose of this study was to evaluate the test-retest relative and absolute reliability of PPT in KOA. For that purpose, intra- and interclass correlation coefficient (ICC) as well as the standard error of measurement (SEM) and the minimal detectable change (MDC) values within eight anatomical locations covering the most painful knee of KOA patients was measured. Twenty KOA patients participated in two sessions with a period of 2 weeks±3 days apart. PPT's were assessed over eight anatomical locations covering the knee and two remote locations over tibialis anterior and brachioradialis. The patients rated their maximum pain intensity during the past 24 h and prior to the recordings on a visual analog scale (VAS), and completed The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and PainDetect surveys. The ICC, SEM and MDC between the sessions were assessed. The ICC for the individual variability was expressed with coefficient of variance (CV). Bland-Altman plots were used to assess potential bias in the dataset. The ICC ranged from 0.85 to 0.96 for all the anatomical locations which is considered "almost perfect". CV was lowest in session 1 and ranged from 44.2 to 57.6%. SEM for comparison ranged between 34 and 71 kPa and MDC ranged between 93 and 197 kPa with a mean PPT ranged from 273.5 to 367.7 kPa in session 1 and 268.1-331.3 kPa in session 2. The analysis of Bland-Altman plot showed no systematic bias. PPT maps showed that the patients had lower thresholds in session 2, but no significant difference was observed for the comparison between the sessions for PPT or VAS. No correlations were seen between PainDetect and PPT and PainDetect and WOMAC

  18. A Test-Retest Analysis of the Vanderbilt Assessment for Leadership in Education in the USA

    Science.gov (United States)

    Minor, Elizabeth Covay; Porter, Andrew C.; Murphy, Joseph; Goldring, Ellen; Elliott, Stephen N.

    2017-01-01

    The Vanderbilt Assessment for Leadership in Education (VAL-ED) is a 360-degree learning-centered behaviors principal evaluation tool that includes ratings from the principal, supervisors, and teachers. The current study assesses the test-retest reliability of the VAL-ED for a sample of seven school districts as part of multiple validity and…

  19. Test-retest reliability of fMRI-based graph theoretical properties during working memory, emotion processing, and resting state.

    Science.gov (United States)

    Cao, Hengyi; Plichta, Michael M; Schäfer, Axel; Haddad, Leila; Grimm, Oliver; Schneider, Michael; Esslinger, Christine; Kirsch, Peter; Meyer-Lindenberg, Andreas; Tost, Heike

    2014-01-01

    The investigation of the brain connectome with functional magnetic resonance imaging (fMRI) and graph theory analyses has recently gained much popularity, but little is known about the robustness of these properties, in particular those derived from active fMRI tasks. Here, we studied the test-retest reliability of brain graphs calculated from 26 healthy participants with three established fMRI experiments (n-back working memory, emotional face-matching, resting state) and two parcellation schemes for node definition (AAL atlas, functional atlas proposed by Power et al.). We compared the intra-class correlation coefficients (ICCs) of five different data processing strategies and demonstrated a superior reliability of task-regression methods with condition-specific regressors. The between-task comparison revealed significantly higher ICCs for resting state relative to the active tasks, and a superiority of the n-back task relative to the face-matching task for global and local network properties. While the mean ICCs were typically lower for the active tasks, overall fair to good reliabilities were detected for global and local connectivity properties, and for the n-back task with both atlases, smallworldness. For all three tasks and atlases, low mean ICCs were seen for the local network properties. However, node-specific good reliabilities were detected for node degree in regions known to be critical for the challenged functions (resting-state: default-mode network nodes, n-back: fronto-parietal nodes, face-matching: limbic nodes). Between-atlas comparison demonstrated significantly higher reliabilities for the functional parcellations for global and local network properties. Our findings can inform the choice of processing strategies, brain atlases and outcome properties for fMRI studies using active tasks, graph theory methods, and within-subject designs, in particular future pharmaco-fMRI studies. © 2013 Elsevier Inc. All rights reserved.

  20. Test–Retest Reliability of Self-Reported Sexual Behavior History in Urbanized Nigerian Women

    Directory of Open Access Journals (Sweden)

    Eileen O. Dareng

    2017-07-01

    Full Text Available BackgroundStudies assessing risk of sexual behavior and disease are often plagued by questions about the reliability of self-reported sexual behavior. In this study, we evaluated the reliability of self-reported sexual history among urbanized women in a prospective study of cervical HPV infections in Nigeria.MethodsWe examined test–retest reliability of sexual practices using questionnaires administered at study entry and at follow-up visits. We used the root mean squared approach to calculate within-person coefficient of variation (CVw and calculated the intra-class correlation coefficient (ICC using two way, mixed effects models for continuous variables and (κ^ statistics for discrete variables. To evaluate the potential predictors of reliability, we used linear regression and log binomial regression models for the continuous and categorical variables, respectively.ResultsWe found that self-reported sexual history was generally reliable, with overall ICC ranging from 0.7 to 0.9; however, the reliability varied by nature of sexual behavior evaluated. Frequency reports of non-vaginal sex (agreement = 63.9%, 95% CI: 47.5–77.6% were more reliable than those of vaginal sex (agreement = 59.1%, 95% CI: 55.2–62.8%. Reports of time-invariant behaviors were also more reliable than frequency reports. The CVw for age at sexual debut was 10.7 (95% CI: 10.6–10.7 compared with the CVw for lifetime number of vaginal sex partners, which was 35.2 (95% CI: 35.1–35.3. The test–retest interval was an important predictor of reliability of responses, with longer intervals resulting in increased inconsistency (average change in unreliability for each 1 month increase = 0.04, 95% CI = 0.07–0.38, p = 0.005.ConclusionOur findings suggest that overall, the self-reported sexual history among urbanized Nigeran women is reliable.

  1. A review of culturally adapted versions of the Oswestry Disability Index: the adaptation process, construct validity, test-retest reliability and internal consistency.

    Science.gov (United States)

    Sheahan, Peter J; Nelson-Wong, Erika J; Fischer, Steven L

    2015-01-01

    The Oswestry Disability Index (ODI) is a self-report-based outcome measure used to quantify the extent of disability related to low back pain (LBP), a substantial contributor to workplace absenteeism. The ODI tool has been adapted for use by patients in several non-English speaking nations. It is unclear, however, if these adapted versions of the ODI are as credible as the original ODI developed for English-speaking nations. The objective of this study was to conduct a review of the literature to identify culturally adapted versions of the ODI and to report on the adaptation process, construct validity, test-retest reliability and internal consistency of these ODIs. Following a pragmatic review process, data were extracted from each study with regard to these four outcomes. While most studies applied adaptation processes in accordance with best-practice guidelines, there were some deviations. However, all studies reported high-quality psychometric properties: group mean construct validity was 0.734 ± 0.094 (indicated via a correlation coefficient), test-retest reliability was 0.937 ± 0.032 (indicated via an intraclass correlation coefficient) and internal consistency was 0.876 ± 0.047 (indicated via Cronbach's alpha). Researchers can be confident when using any of these culturally adapted ODIs, or when comparing and contrasting results between cultures where these versions were employed. Implications for Rehabilitation Low back pain is the second leading cause of disability in the world, behind only cancer. The Oswestry Disability Index (ODI) has been developed as a self-report outcome measure of low back pain for administration to patients. An understanding of the various cross-cultural adaptations of the ODI is important for more concerted multi-national research efforts. This review examines 16 cross-cultural adaptations of the ODI and should inform the work of health care and rehabilitation professionals.

  2. Escala Razões para Fumar Modificada: tradução e adaptação cultural para o português para uso no Brasil e avaliação da confiabilidade teste-reteste Modified Reasons for Smoking Scale: translation to Portuguese, cross-cultural adaptation for use in Brazil and evaluation of test-retest reliability

    Directory of Open Access Journals (Sweden)

    Elisa Sebba Tosta de Souza

    2009-07-01

    Full Text Available OBJETIVO: Traduzir, fazer a adaptação cultural e testar a confiabilidade teste-reteste de uma versão em língua portuguesa da Escala Razões Para Fumar Modificada (ERPFM para uso no Brasil. MÉTODOS: Uma versão em língua inglesa da ERPFM foi traduzida por médicos brasileiros com profundo conhecimento sobre a língua inglesa. Uma versão de consenso foi obtida por grupo multidisciplinar composto por dois pneumologistas, um psiquiatra e um psicólogo. Essa versão foi traduzida de volta ao inglês por um tradutor americano. A avaliação da adaptação cultural da versão final foi efetuada em uma amostra de 20 fumantes saudáveis. A avaliação da confiabilidade teste-reteste foi feita pela aplicação da versão traduzida da escala em 54 fumantes saudáveis em duas ocasiões separadas por 15 dias. RESULTADOS: Essa versão traduzida da ERPFM exibiu excelente identidade cultural, sendo bem compreendida por 95% dos fumantes. Os graus de concordância das respostas em duas ocasiões distintas foram quase perfeito para duas questões, substancial para dez questões, moderado para oito questões e discreto para uma questão. Os valores dos coeficientes de correlação intraclasse dos fatores motivacionais em duas ocasiões, empregando-se modelos teóricos previamente publicados, foram superiores a 0,7 em seis dos sete domínios. CONCLUSÕES: A presente versão da ERPFM exibe identidade cultural e confiabilidade teste-reteste satisfatórias, podendo ser de utilidade no tratamento e na avaliação de tabagistas em nosso meio.OBJECTIVE: To translate the Modified Reasons for Smoking Scale (MRSS to Portuguese, to submit it to cross-cultural adaptation for use in Brazil and to evaluate the test-retest reliability of the translated version. METHODS: An English-language version of the MRSS was translated to Portuguese by Brazilian doctors who have thorough knowledge of the English language. A consensus version was produced by a multidisciplinary group

  3. Intra- and inter-rater reliability of the Sollerman hand function test in patients with chronic stroke

    DEFF Research Database (Denmark)

    Brogårdh, Christina; Persson, Ann L; Sjölund, Bengt H

    2007-01-01

    PURPOSE: To examine whether the Sollerman hand function test is reliable in a test-retest situation in patients with chronic stroke. METHOD: Three independent examiners observed each patient at three experimental sessions; two days in week 1 (short-term test-retest) and one day in week 4 (long...... test seems to be a reliable test in patients with chronic stroke, but we recommend that the same examiner evaluates a patient's hand function pre- and post-treatment.......-term test-retest). A total of 24 patients with chronic stroke (mean age; 59.7 years, mean time since stroke onset 29.6 months) participated. The examiners simultaneously assessed the patients' ability to perform 20 subtests. Both ordinal data (generalized kappa) and total sum scores (Spearman's rank...

  4. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue.

    Science.gov (United States)

    Troester, Jordan C; Jasmin, Jason G; Duffield, Rob

    2018-06-01

    The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test - re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  5. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue

    Directory of Open Access Journals (Sweden)

    Jordan C. Troester, Jason G. Jasmin, Rob Duffield

    2018-06-01

    Full Text Available The present study examined the inter-trial (within test and inter-test (between test reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA. Twenty-four players undertook testre-test measures on two occasions (7 days apart on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13% for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13% was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%. Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%. Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%. Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  6. Test–retest reliability of Antonovsky’s 13-item sense of coherence scale in patients with handrelated disorders

    DEFF Research Database (Denmark)

    Hansen, Alice Ørts; Kristensen, Hanne Kaae; Cederlund, Ragnhild

    2016-01-01

    Purpose: To report on the distribution and test-retest reliability of Antonovsky’s 13-item Sense of Coherence (SOC-13) Scale in patients with hand-related disorders (HRD). Links between the SOC-13 score and factors such as age, number of days between date of injury and start of rehabilitation, ge...... to be a powerful tool to measure the ICF component personal factors, which could have an impact on patients’ rehabilitation outcomes....

  7. Reliability of cognitive tests of ELSA-Brasil, the brazilian longitudinal study of adult health

    Science.gov (United States)

    Batista, Juliana Alves; Giatti, Luana; Barreto, Sandhi Maria; Galery, Ana Roscoe Papini; Passos, Valéria Maria de Azeredo

    2013-01-01

    Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. OBJECTIVES We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. METHODS The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age) from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years). The Intraclass Correlation Coefficient (ICC) was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. RESULTS We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56), Word Recall (0.50), Word Recognition (0.35), Phonemic Verbal Fluency Test (VFT, 0.61), Semantic VFT (0.53) and Trail B (0.91). The Bland-Altman plot showed better correlation of executive function (VFT and Trail B) than of memory tests. CONCLUSIONS Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable. PMID:29213860

  8. Reliability of Cognitive Tests of ELSA-Brasil, the Brazilian Longitudinal Study of Adult Health

    Directory of Open Access Journals (Sweden)

    Juliana Alves Batista

    Full Text Available ABSTRACT Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. Objectives: We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. Methods: The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years. The Intraclass Correlation Coefficient (ICC was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. Results: We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56, Word Recall (0.50, Word Recognition (0.35, Phonemic Verbal Fluency Test (VFT, 0.61, Semantic VFT (0.53 and Trail B (0.91. The Bland-Altman plot showed better correlation of executive function (VFT and Trail B than of memory tests. Conclusions: Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable.

  9. Can local staff reliably assess their own programs? A confirmatory test-retest study of Lot Quality Assurance Sampling data collectors in Uganda.

    Science.gov (United States)

    Beckworth, Colin A; Anguyo, Robert; Kyakulaga, Francis Cranmer; Lwanga, Stephen K; Valadez, Joseph J

    2016-08-17

    Data collection techniques that routinely provide health system information at the local level are in demand and needed. LQAS is intended for use by local health teams to collect data at the district and sub-district levels. Our question is whether local health staff produce biased results as they are responsible for implementing the programs they also assess. This test-retest study replicates on a larger scale an earlier LQAS reliability assessment in Uganda. We conducted in two districts an LQAS survey using 15 local health staff as data collectors. A week later, the data collectors swapped districts, where they acted as disinterested non-local data collectors, repeating the LQAS survey with the same respondents. We analysed the resulting two data sets for agreement using Cohens' Kappa. The average Kappa score for the knowledge indicators was k = 0.43 (SD = 0.16) and for practice indicators k = 0.63 (SD = 0.17). These scores show moderate agreement for knowledge indicators and substantial agreement for practice indicators. Analyses confirm that respondents were more knowledgeable on retest; no evidence of bias was found for practice indicators. The findings of this study are remarkably similar to those produced in the first reliability study. There is no evidence that using local healthcare staff to collect LQAS data biases data collection in an LQAS study. The bias observed in the knowledge indicators was most likely due to a 'practice effect', whereby respondents increased their knowledge as a result of completing the first survey; no corresponding effect was seen in the practice indicators.

  10. Reliability, construct and discriminative validity of clinical testing in subjects with and without chronic neck pain

    DEFF Research Database (Denmark)

    Jørgensen, René; Ris Hansen, Inge; Falla, Deborah

    2014-01-01

    -retest reliability in people with and without chronic neck pain. Moreover, construct and between-group discriminative validity of the tests were examined. METHODS: Twenty-one participants with chronic neck pain and 21 asymptomatic participants were included. Intra- and inter-reliability were evaluated for the Cranio-Cervical...... Flexion Test (CCFT), Range of Movement (ROM), Joint Position Error (JPE), Gaze Stability (GS), Smooth Pursuit Neck Torsion Test (SPNTT), and neuromuscular control of the Deep Cervical Extensors (DCE). Test-retest reliability was assessed for Postural Control (SWAY) and Pressure Pain Threshold (PPT) over......BACKGROUND: The reliability of clinical tests for the cervical spine has not been adequately evaluated. Six cervical clinical tests, which are low cost and easy to perform in clinical settings, were tested for intra- and inter-examiner reliability, and two performance tests were assessed for test...

  11. Test-retest reliability of diffusion tensor imaging of the liver at 3.0 T.

    Science.gov (United States)

    Girometti, Rossano; Maieron, Marta; Lissandrello, Giovanni; Bazzocchi, Massimo; Zuiani, Chiara

    2015-06-01

    This study was done to evaluate test-retest reliability of liver diffusion tensor imaging (LDTI). Ten healthy volunteers (median age 23 years) underwent two LDTI scans on a 3.0 T magnet during two imaging sessions separated by 2 weeks (session-1/-2, respectively). Fifteen gradient directions and b values of 0-1,000 s/mm(2) were used. Two radiologists in consensus assessed liver apparent diffusion coefficient (ADC) and fraction of anisotropy (FA) values on ADC and FA maps at four reference levels, namely: right upper level (RUL), right lower level (RLL), left upper level (LUL) and left lower level (LLL). We then assessed (a) whether ADC and FA values overlapped when measured on different levels within the same imaging session or between different imaging sessions; (b) the degree of variability on an intra-session and inter-session basis, respectively, using the coefficient of variation (CV). In sessions 1 and 2, the ADC/FA values were significantly larger in the left liver lobe (LUL/LLL) compared to right liver lobe (RUL/RLL) (p < 0.05/6). Intra-session CVs were 9.51 % (session 1) and 9.73 % (session 2) for ADC, and 12.93 % (session 1) and 11.82 % (session 2) for FA, respectively. When comparing RUL, RLL, LUL and LLL on an inter-session basis, CVs were 6.52, 8.20, 6.52 and 11.06 % for ADC, and 15.42, 15.80, 15.42 and 6.80 % for FA, respectively. LDTI provides consistent and repeatable measurements. However, since larger left lobe ADC/FA values can be attributed to artefacts, right lobe values should be considered the most reliable measurements of water diffusivity within the liver.

  12. Test-retest reliability of the Food Allergy Quality of Life Questionnaires (FAQLQ) for children, adolescents and adults

    NARCIS (Netherlands)

    van der Velde, Jantina L.; Flokstra-de Blok, Bertine M. J.; Vlieg - Boerstra, Berber J.; Oude Elberink, Joanne N. G.; Schouten, Jan P.; DunnGalvin, Audrey; Hourihane, Jonathan O'B; Duiverman, Eric J.; Dubois, Anthony E. J.

    The self-administered Food Allergy Quality of Life Questionnaire-Child Form (FAQLQ-CF), -Teenager Form (FAQLQ-TF) and -Adult Form (FAQLQ-AF) were recently developed within EuroPrevall, a multi-centred study of food allergy in Europe. The primary aim of this study was to evaluate the test-retest

  13. Test-retest reliability of the Food Allergy Quality of Life Questionnaires (FAQLQ) for children, adolescents and adults

    NARCIS (Netherlands)

    van der Velde, Jantina L.; Flokstra-de Blok, Bertine M. J.; Vlieg-Boerstra, Berber J.; Oude Elberink, Joanne N. G.; Schouten, Jan P.; DunnGalvin, Audrey; Hourihane, Jonathan O.'B.; Duiverman, Eric J.; Dubois, Anthony E. J.

    2009-01-01

    The self-administered Food Allergy Quality of Life Questionnaire-Child Form (FAQLQ-CF), -Teenager Form (FAQLQ-TF) and -Adult Form (FAQLQ-AF) were recently developed within EuroPrevall, a multi-centred study of food allergy in Europe. The primary aim of this study was to evaluate the test-retest

  14. The Phoneme Identification Test for Assessment of Spectral and Temporal Discrimination Skills in Children: Development, Normative Data, and Test-Retest Reliability Studies.

    Science.gov (United States)

    Cameron, Sharon; Chong-White, Nicky; Mealings, Kiri; Beechey, Tim; Dillon, Harvey; Young, Taegan

    2018-02-01

    Previous research suggests that a proportion of children experiencing reading and listening difficulties may have an underlying primary deficit in the way that the central auditory nervous system analyses the perceptually important, rapidly varying, formant frequency components of speech. The Phoneme Identification Test (PIT) was developed to investigate the ability of children to use spectro-temporal cues to perceptually categorize speech sounds based on their rapidly changing formant frequencies. The PIT uses an adaptive two-alternative forced-choice procedure whereby the participant identifies a synthesized consonant-vowel (CV) (/ba/ or /da/) syllable. CV syllables differed only in the second formant (F2) frequency along an 11-step continuum (between 0% and 100%-representing an ideal /ba/ and /da/, respectively). The CV syllables were presented in either quiet (PIT Q) or noise at a 0 dB signal-to-noise ratio (PIT N). Development of the PIT stimuli and test protocols, and collection of normative and test-retest reliability data. Twelve adults (aged 23 yr 10 mo to 50 yr 9 mo, mean 32 yr 5 mo) and 137 typically developing, primary-school children (aged 6 yr 0 mo to 12 yr 4 mo, mean 9 yr 3 mo). There were 73 males and 76 females. Data were collected using a touchscreen computer. Psychometric functions were automatically fit to individual data by the PIT software. Performance was determined by the width of the continuum for which responses were neither clearly /ba/ nor /da/ (referred to as the uncertainty region [UR]). A shallower psychometric function slope reflected greater uncertainty. Age effects were determined based on raw scores. Z scores were calculated to account for the effect of age on performance. Outliers, and individual data for which the confidence interval of the UR exceeded a maximum allowable value, were removed. Nonparametric tests were used as the data were skewed toward negative performance. Across participants, the median value of the F2 range

  15. Adaptation and testing of psychosocial assessment instruments for cross-cultural use: an example from the Thailand Burma border.

    Science.gov (United States)

    Haroz, Emily E; Bass, Judith K; Lee, Catherine; Murray, Laura K; Robinson, Courtland; Bolton, Paul

    2014-01-01

    The purpose of this study was to develop valid and reliable instruments to assess priority psychosocial problems and functioning among adult survivors of systematic violence from Burma living in Thailand. The process involved four steps: 1) instrument drafting and piloting; 2) reliability and validity testing; 3) instrument revision; and 4) retesting revised instrument. A total of N = 158 interviews were completed. Overall subscales showed good internal consistency (0.73-0.92) and satisfactory combined test-retest/inter rater reliability (0.63-0.84). Criterion validity, was not demonstrated for any scale. The alcohol and functioning scales underperformed and were revised (step 3) and retested (step 4). Upon retesting, the function scale showed good internal consistency reliability (0.91-0.92), and the alcohol scale showed acceptable internal consistency (0.79) and strong test-retest/inter-rater reliability (0.86-0.89). This paper describes the importance and process of adaptation and testing, illustrated by the experiences and results for selected instruments in this population.

  16. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  17. Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire

    Science.gov (United States)

    Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra

    2018-05-29

    Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Methodological and cross sectional study. A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain.

  18. Attentional and visual demands for sprint performance in non-fatigued and fatigued conditions: reliability of a repeated sprint test

    Directory of Open Access Journals (Sweden)

    Diercks Ron L

    2010-05-01

    Full Text Available Abstract Background Physical performance measures are widely used to assess physical function, providing information about physiological and biomechanical aspects of motor performance. However they do not provide insight into the attentional and visual demands for motor performance. A figure-of-eight sprint test was therefore developed to measure the attentional and visual demands for repeated-sprint performance. The aims of the study were: 1 to assess test-retest reliability of the figure-of-eight sprint test, and 2 to study the attentional and visual demands for sprint performance in a non-fatigued and fatigued condition. Methods Twenty-seven healthy athletes were included in the study. To determine test-retest reliability, a subgroup of 19 athletes performed the figure-of-eight sprint test twice. The figure-of-eight sprint test consisted of nine 30-second sprints. The sprint test consisted of three test parts: sprinting without any restriction, with an attention-demanding task, and with restricted vision. Increases in sprint times with the attention-demanding task or restricted vision are reflective of the attentional and visual demands for sprinting. Intraclass correlation coefficients (ICCs and mean difference between test and retest with 95% confidence limits (CL were used to assess test-retest reliability. Repeated-measures ANOVA were used for comparisons between the sprint times and fatigue measurements of the test parts in both a non-fatigued and fatigued condition. Results The figure-of-eight sprint test showed good test-retest reliability, with ICCs ranging from 0.75 to 0.94 (95% CL: 0.40-0.98. Zero lay within the 95% CL of the mean differences, indicating that no bias existed between sprint performance at test and retest. Sprint times during the test parts with attention-demanding task (P = 0.01 and restricted vision (P Conclusions High ICCs and the absence of systematic variation indicate good test-retest reliability of the figure

  19. Validity and Reliability of the 8-Item Work Limitations Questionnaire.

    Science.gov (United States)

    Walker, Timothy J; Tullar, Jessica M; Diamond, Pamela M; Kohl, Harold W; Amick, Benjamin C

    2017-12-01

    Purpose To evaluate factorial validity, scale reliability, test-retest reliability, convergent validity, and discriminant validity of the 8-item Work Limitations Questionnaire (WLQ) among employees from a public university system. Methods A secondary analysis using de-identified data from employees who completed an annual Health Assessment between the years 2009-2015 tested research aims. Confirmatory factor analysis (CFA) (n = 10,165) tested the latent structure of the 8-item WLQ. Scale reliability was determined using a CFA-based approach while test-retest reliability was determined using the intraclass correlation coefficient. Convergent/discriminant validity was tested by evaluating relations between the 8-item WLQ with health/performance variables for convergent validity (health-related work performance, number of chronic conditions, and general health) and demographic variables for discriminant validity (gender and institution type). Results A 1-factor model with three correlated residuals demonstrated excellent model fit (CFI = 0.99, TLI = 0.99, RMSEA = 0.03, and SRMR = 0.01). The scale reliability was acceptable (0.69, 95% CI 0.68-0.70) and the test-retest reliability was very good (ICC = 0.78). Low-to-moderate associations were observed between the 8-item WLQ and the health/performance variables while weak associations were observed between the demographic variables. Conclusions The 8-item WLQ demonstrated sufficient reliability and validity among employees from a public university system. Results suggest the 8-item WLQ is a usable alternative for studies when the more comprehensive 25-item WLQ is not available.

  20. Improving QST Reliability – More Raters, Tests or Occasions? A Multivariate Generalizability Study

    DEFF Research Database (Denmark)

    O'Neill, Søren; O'Neill, Lotte

    2015-01-01

    The reliability of quantitative sensory testing (QST) is affected by the error attributable to both test occasion and rater (examiner) as well as interactions between them. Most reliability studies only account for one source of error. The present study employed a fully-crossed, multivariate...... threshold, intensity, tolerance and modulation with mechanical, thermal and chemical stimuli. The classical test-retest and inter-rater reliability (0.19... procedures. Reliability was improved more by repeated testing on separate occasions opposed to repeated testing by different raters....

  1. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

    Directory of Open Access Journals (Sweden)

    Nussbaumer Silvio

    2010-08-01

    Full Text Available Abstract Background The aims of this study were to evaluate the construct validity (known group, concurrent validity (criterion based and test-retest (intra-rater reliability of manual goniometers to measure passive hip range of motion (ROM in femoroacetabular impingement patients and healthy controls. Methods Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study. Results The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P P Conclusions The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.

  2. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing.

    Science.gov (United States)

    DiFilippo, Kristen Nicole; Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-10-27

    The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps' educational quality and technical functionality. Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no

  3. Willing and able: a closer look at pain Willingness and Activity Engagement on the Chronic Pain Acceptance Questionnaire (CPAQ-8).

    Science.gov (United States)

    Fish, Rosemary A; Hogan, Michael J; Morrison, Todd G; Stewart, Ian; McGuire, Brian E

    2013-03-01

    An 8-item version of the Chronic Pain Acceptance Questionnaire (CPAQ-8) has recently been proposed and validated. The aims of this study were to further investigate the reliability and validity of the CPAQ-8 in a new sample. Questionnaires were completed by 550 people with chronic pain (478 online survey, 72 paper survey). A demographic and pain history questionnaire was administered along with the CPAQ-8 and measures of pain self-efficacy, pain catastrophizing, psychological flexibility in pain, anxiety, and mood. In addition, 105 respondents completed the CPAQ-8 within 6 weeks to provide test-retest reliability data. The 2-factor structure of the CPAQ-8 (Activity Engagement [AE] and Pain Willingness [PW]) was confirmed and had reasonable-to-good scale score reliability and test-retest reliability. Pain acceptance as measured by the CPAQ-8 was associated with less depression, anxiety, pain interference, fear of reinjury, pain catastrophizing, and psychological inflexibility in pain, and higher levels of satisfaction with life, pain self-efficacy, and general acceptance. Furthermore, pain acceptance fully mediated the relationship between reported pain severity and emotional distress (anxiety and depression) and partially mediated the relationship between pain severity and pain interference in a structural equation model. The test-retest reliability after 4 to 6 weeks ranged from .68 for PW to .86 for AE; the overall score correlation was .81. We conclude that the CPAQ-8 is a reliable and valid measure of pain acceptance and that the 2 subscales of the measure each make an individual contribution to the prediction of adjustment in people with chronic pain. The present study provides further evidence for the reliability and validity of the CPAQ-8. Support was found for the 2 related subscales, PW and AE, which appear to work in synergy to influence levels of pain interference and emotional distress in people living with chronic pain. Copyright © 2013 American

  4. Workplace-based assessment of communication skills: A pilot project addressing feasibility, acceptance and reliability

    Science.gov (United States)

    Weyers, Simone; Jemi, Iman; Karger, André; Raski, Bianca; Rotthoff, Thomas; Pentzek, Michael; Mortsiefer, Achim

    2016-01-01

    Background: Imparting communication skills has been given great importance in medical curricula. In addition to standardized assessments, students should communicate with real patients in actual clinical situations during workplace-based assessments and receive structured feedback on their performance. The aim of this project was to pilot a formative testing method for workplace-based assessment. Our investigation centered in particular on whether or not physicians view the method as feasible and how high acceptance is among students. In addition, we assessed the reliability of the method. Method: As part of the project, 16 students held two consultations each with chronically ill patients at the medical practice where they were completing GP training. These consultations were video-recorded. The trained mentoring physician rated the student’s performance and provided feedback immediately following the consultations using the Berlin Global Rating scale (BGR). Two impartial, trained raters also evaluated the videos using BGR. For qualitative and quantitative analysis, information on how physicians and students viewed feasibility and their levels of acceptance was collected in written form in a partially standardized manner. To test for reliability, the test-retest reliability was calculated for both of the overall evaluations given by each rater. The inter-rater reliability was determined for the three evaluations of each individual consultation. Results: The formative assessment method was rated positively by both physicians and students. It is relatively easy to integrate into daily routines. Its significant value lies in the personal, structured and recurring feedback. The two overall scores for each patient consultation given by the two impartial raters correlate moderately. The degree of uniformity among the three raters in respect to the individual consultations is low. Discussion: Within the scope of this pilot project, only a small sample of physicians and

  5. Workplace-based assessment of communication skills: A pilot project addressing feasibility, acceptance and reliability

    Directory of Open Access Journals (Sweden)

    Weyers, Simone

    2016-11-01

    Full Text Available Background: Imparting communication skills has been given great importance in medical curricula. In addition to standardized assessments, students should communicate with real patients in actual clinical situations during workplace-based assessments and receive structured feedback on their performance. The aim of this project was to pilot a formative testing method for workplace-based assessment. Our investigation centered in particular on whether or not physicians view the method as feasible and how high acceptance is among students. In addition, we assessed the reliability of the method.Method: As part of the project, 16 students held two consultations each with chronically ill patients at the medical practice where they were completing GP training. These consultations were video-recorded. The trained mentoring physician rated the student’s performance and provided feedback immediately following the consultations using the Berlin Global Rating scale (BGR. Two impartial, trained raters also evaluated the videos using BGR. For qualitative and quantitative analysis, information on how physicians and students viewed feasibility and their levels of acceptance was collected in written form in a partially standardized manner. To test for reliability, the test-retest reliability was calculated for both of the overall evaluations given by each rater. The inter-rater reliability was determined for the three evaluations of each individual consultation.Results: The formative assessment method was rated positively by both physicians and students. It is relatively easy to integrate into daily routines. Its significant value lies in the personal, structured and recurring feedback. The two overall scores for each patient consultation given by the two impartial raters correlate moderately. The degree of uniformity among the three raters in respect to the individual consultations is low.Discussion: Within the scope of this pilot project, only a small sample

  6. Workplace-based assessment of communication skills: A pilot project addressing feasibility, acceptance and reliability.

    Science.gov (United States)

    Weyers, Simone; Jemi, Iman; Karger, André; Raski, Bianca; Rotthoff, Thomas; Pentzek, Michael; Mortsiefer, Achim

    2016-01-01

    Background: Imparting communication skills has been given great importance in medical curricula. In addition to standardized assessments, students should communicate with real patients in actual clinical situations during workplace-based assessments and receive structured feedback on their performance. The aim of this project was to pilot a formative testing method for workplace-based assessment. Our investigation centered in particular on whether or not physicians view the method as feasible and how high acceptance is among students. In addition, we assessed the reliability of the method. Method: As part of the project, 16 students held two consultations each with chronically ill patients at the medical practice where they were completing GP training. These consultations were video-recorded. The trained mentoring physician rated the student's performance and provided feedback immediately following the consultations using the Berlin Global Rating scale (BGR). Two impartial, trained raters also evaluated the videos using BGR. For qualitative and quantitative analysis, information on how physicians and students viewed feasibility and their levels of acceptance was collected in written form in a partially standardized manner. To test for reliability, the test-retest reliability was calculated for both of the overall evaluations given by each rater. The inter-rater reliability was determined for the three evaluations of each individual consultation. Results: The formative assessment method was rated positively by both physicians and students. It is relatively easy to integrate into daily routines. Its significant value lies in the personal, structured and recurring feedback. The two overall scores for each patient consultation given by the two impartial raters correlate moderately. The degree of uniformity among the three raters in respect to the individual consultations is low. Discussion: Within the scope of this pilot project, only a small sample of physicians and

  7. Reliability and validity of the rey visual design learning test in primary school children

    NARCIS (Netherlands)

    Wilhelm, P.

    2004-01-01

    The Rey Visual Design Learning Test (Rey, 1964, in Spreen & Strauss, 1991) assesses immediate memory span, new learning and recognition for non-verbal material. Three studies are presented that focused on the reliability and validity of the RVDLT in primary school children. Test-retest reliability

  8. Response process and test–retest reliability of the Context Assessment for Community Health tool in Vietnam

    Directory of Open Access Journals (Sweden)

    Duong M. Duc

    2016-06-01

    Full Text Available Background: The recently developed Context Assessment for Community Health (COACH tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources , community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment through 49 items. Objective: The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. Designs: To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test–retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC and percent agreement and dimensions (ICC and Bland–Altman plots. Results: In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test–retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5–0.7, demonstrating that the instrument has an acceptable level of stability. Conclusions: This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify

  9. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review.

    Science.gov (United States)

    Ratter, Julia; Radlinger, Lorenz; Lucas, Cees

    2014-09-01

    Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. Copyright © 2014. Published by Elsevier B.V.

  10. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  11. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    Science.gov (United States)

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  12. Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire

    Directory of Open Access Journals (Sweden)

    Hazel Ekin Akmaz

    2018-05-01

    Full Text Available Background: Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. Aims: To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Study Design: Methodological and cross sectional study. Methods: A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. Results: The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. Conclusion: The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance

  13. Test-retest reliability of {sup 11}C-ORM-13070 in PET imaging of α{sub 2C}-adrenoceptors in vivo in the human brain

    Energy Technology Data Exchange (ETDEWEB)

    Lehto, Jussi; Peltonen, Juha M.; Volanen, Iina; Scheinin, Mika [University of Turku, Clinical Research Services Turku CRST, Turku (Finland); TYKSLAB, Unit of Clinical Pharmacology, Turku (Finland); Virta, Jere R. [University of Turku and Turku University Hospital, Turku PET Centre, Turku (Finland); Turku University Hospital, Division of Clinical Neurosciences, Turku (Finland); Oikonen, Vesa; Roivainen, Anne; Luoto, Pauliina; Arponen, Eveliina; Helin, Semi; Virtanen, Kirsi [University of Turku and Turku University Hospital, Turku PET Centre, Turku (Finland); Hietamaeki, Johanna; Holopainen, Aila; Rouru, Juha; Sallinen, Jukka [Orion Pharma, Turku (Finland); Kailajaervi, Marita [Turku Imanet, GE Healthcare, Turku (Finland); Rinne, Juha O. [University of Turku and Turku University Hospital, Turku PET Centre, Turku (Finland); Turku University Hospital, Division of Clinical Neurosciences, Turku (Finland); University of Turku, Clinical Research Services Turku CRST, Turku (Finland)

    2015-01-15

    α{sub 2C}-Adrenoceptors share inhibitory presynaptic functions with the more abundant α{sub 2A}-adrenoceptor subtype, but they also have widespread postsynaptic modulatory functions in the brain. Research on the noradrenergic system of the human brain has been hampered by the lack of suitable PET tracers targeted to the α{sub 2}-adrenoceptor subtypes. PET imaging with the specific α{sub 2C}-adrenoceptor antagonist tracer [{sup 11}C]ORM-13070 was performed twice in six healthy male subjects to investigate the test-retest reliability of tracer binding. The bound/free ratio of tracer uptake relative to nonspecific uptake into the cerebellum during the time interval of 5 - 30 min was most prominent in the dorsal striatum: 0.77 in the putamen and 0.58 in the caudate nucleus. Absolute test-retest variability in bound/free ratios of tracer ranged from 4.3 % in the putamen to 29 % in the hippocampus. Variability was also <10 % in the caudate nucleus and thalamus. Intraclass correlation coefficients (ICC) ranged from 0.50 in the hippocampus to 0.89 in the thalamus (ICC >0.70 was also reached in the caudate nucleus, putamen, lateral frontal cortex and parietal cortex). The pattern of [{sup 11}C]ORM-13070 binding, as determined by PET, was in good agreement with receptor density results previously derived from post-mortem autoradiography. PET data analysis results obtained with a compartmental model fit, the simplified reference tissue model and a graphical reference tissue analysis method were convergent with the tissue ratio method. The results of this study support the use of [{sup 11}C]ORM-13070 PET in the quantitative assessment of α{sub 2C}-adrenoceptors in the human brain in vivo. Reliable assessment of specific tracer binding in the dorsal striatum is possible with the help of reference tissue ratios. (orig.)

  14. Assessing the test-retest repeatability of the Vietnamese version of the National Eye Institute 25-item Visual Function Questionnaire among bilateral cataract patients for a Vietnamese population.

    Science.gov (United States)

    To, Kien Gia; Meuleners, Lynn; Chen, Huei-Yang; Lee, Andy; Do, Dung Van; Duong, Dat Van; Phi, Tien Duy; Tran, Hoang Huy; Nguyen, Nguyen Do

    2014-06-01

    To determine the test-retest repeatability of the National Eye Institute 25-item Visual Function Questionnaire (NEI VFQ-25) for use with older Vietnamese adults with bilateral cataract. The questionnaire was translated into Vietnamese and back-translated into English by two independent translators. Patients with bilateral cataract aged 50 and older completed the questionnaire on two separate occasions, one to two weeks after first administration of the questionnaire. Test-retest repeatability was assessed using the Cronbach's α and intraclass correlation coefficients. The average age of participants was 67 ± 8 years and most participants were female (73%). Internal consistency was acceptable with the α coefficient above 0.7 for all subscales and intraclass correlation coefficients were 0.6 or greater in all subscales. The Vietnamese NEI VFQ-25 is reliable for use in studies assessing vision-related quality of life in older adults with bilateral cataract in Vietnam. We propose some modifications to the NEI-VFQ questions to reflect activities of older people in Vietnam. © 2013 ACOTA.

  15. Validity and test–retest reliability of the Persian version of the Montgomery–Asberg Depression Rating Scale

    Science.gov (United States)

    Ahmadpanah, Mohammad; Sheikhbabaei, Meisam; Haghighi, Mohammad; Roham, Fatemeh; Jahangard, Leila; Akhondi, Amineh; Sadeghi Bahmani, Dena; Bajoghli, Hafez; Holsboer-Trachsler, Edith; Brand, Serge

    2016-01-01

    Background and aims The Montgomery–Asberg Depression Rating Scale (MADRS) is an expert’s rating tool to assess the severity and symptoms of depression. The aim of the present two studies was to validate the Persian version of the MADRS and determine its test–retest reliability in patients diagnosed with major depressive disorders (MDD). Methods In study 1, the translated MADRS and the Hamilton Depression Rating Scale (HDRS) were applied to 210 patients diagnosed with MDD and 100 healthy adults. In study 2, 200 patients diagnosed with MDD were assessed with the MADRS in face-to-face interviews. Thereafter, 100 patients were assessed 3–14 days later, again via face-to-face-interviews, while the other 100 patients were assessed 3–14 days later via a telephone interview. Results Study 1: The MADRS and HDRS scores between patients with MDD and healthy controls differed significantly. Agreement between scoring of the MADRS and HDRS was high (r=0.95). Study 2: The intraclass correlation coefficient (test–retest reliability) was r=0.944 for the face-to-face interviews, and r=0.959 for the telephone interviews. Conclusion The present data suggest that the Persian MADRS has high validity and excellent test–retest reliability over a time interval of 3–14 days, irrespective of whether the second assessment was carried out face-to-face or via a telephone interview. PMID:27022265

  16. Development and Validation of the Persian Version of the Acceptable Noise Level (ANL Test in Normal Children Aged 5-8 Years

    Directory of Open Access Journals (Sweden)

    Abdollah Moossavi

    2016-06-01

    Full Text Available Background: The goal of the present study was to develop and validate the Persian version of the Acceptable Noise Level (ANL test in normal, Persianspeaking children aged 5-8 years. Methods: This tool-making and non-experimental research was conducted in two stages. In the first stage the proper story was selected and recorded after evaluation of its content validity. In the second stage this test material was administered to a total 181 normal children (97 girls and 84 boys randomly chosen from the population of preschool and primary school children of Tehran (District 5, aged 5-8 years in four age groups to evaluate the reliability of test in order to develop the Persian version of the ANL test and assess its changes during the growth. Lawshe’s method and Cronbach’s alpha coefficient were used to assess the content validity and reliability of the test, respectively. Mann– Whitney U test was used to examine gender differences, and Kruskal-Wallis test was to examine age differences. Results: Test-retest correlation of 0.74 indicated acceptable reliability of the test. Significant differences were found between most of different age groups for the ANL mean scores (P0.05. Conclusion: The study results indicated good validity and reliability of the Persian version of the ANL test in children. Therefore this test can be useful in designing classrooms suitable for 5-8 year-old children of both genders.

  17. Statistical Considerations in Choosing a Test Reliability Coefficient. ACT Research Report Series, 2012 (10)

    Science.gov (United States)

    Woodruff, David; Wu, Yi-Fang

    2012-01-01

    The purpose of this paper is to illustrate alpha's robustness and usefulness, using actual and simulated educational test data. The sampling properties of alpha are compared with the sampling properties of several other reliability coefficients: Guttman's lambda[subscript 2], lambda[subscript 4], and lambda[subscript 6]; test-retest reliability;…

  18. Static and Dynamic Handgrip Strength Endurance: Test-Retest Reproducibility.

    Science.gov (United States)

    Gerodimos, Vassilis; Karatrantou, Konstantina; Psychou, Dimitra; Vasilopoulou, Theodora; Zafeiridis, Andreas

    2017-03-01

    This study investigated the reliability of static and dynamic handgrip strength endurance using different protocols and indicators for the assessment of strength endurance. Forty young, healthy men and women (age, 18-22 years) performed 2 handgrip strength endurance protocols: a static protocol (sustained submaximal contraction at 50% of maximal voluntary contraction) and a dynamic one (8, 10, and 12 maximal repetitions). The participants executed each protocol twice to assess the test-retest reproducibility. Total work and total time were used as indicators of strength endurance in the static protocol; the strength recorded at each maximal repetition, the percentage change, and fatigue index were used as indicators of strength endurance in the dynamic protocol. The static protocol showed high reliability irrespective of sex and hand for total time and work. The 12-repetition dynamic protocol exhibited moderate-high reliability for repeated maximal repetitions and percentage change; the 8- and 10-repetition protocols demonstrated lower reliability irrespective of sex and hand. The fatigue index was not a reliable indicator for the assessment of dynamic handgrip endurance. Static handgrip endurance can be measured reliably using the total time and total work as indicators of strength endurance. For the evaluation of dynamic handgrip endurance, the 12-repetition protocol is recommended, using the repeated maximal repetitions and percentage change as indicators of strength endurance. Practitioners should consider the static (50% maximal voluntary contraction) and dynamic (12 repeated maximal repetitions) protocols as reliable for the assessment of handgrip strength endurance. The evaluation of static endurance in conjunction with dynamic endurance would provide more complete information about hand function. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. An alternative to the balance error scoring system: using a low-cost balance board to improve the validity/reliability of sports-related concussion balance testing.

    Science.gov (United States)

    Chang, Jasper O; Levy, Susan S; Seay, Seth W; Goble, Daniel J

    2014-05-01

    Recent guidelines advocate sports medicine professionals to use balance tests to assess sensorimotor status in the management of concussions. The present study sought to determine whether a low-cost balance board could provide a valid, reliable, and objective means of performing this balance testing. Criterion validity testing relative to a gold standard and 7 day test-retest reliability. University biomechanics laboratory. Thirty healthy young adults. Balance ability was assessed on 2 days separated by 1 week using (1) a gold standard measure (ie, scientific grade force plate), (2) a low-cost Nintendo Wii Balance Board (WBB), and (3) the Balance Error Scoring System (BESS). Validity of the WBB center of pressure path length and BESS scores were determined relative to the force plate data. Test-retest reliability was established based on intraclass correlation coefficients. Composite scores for the WBB had excellent validity (r = 0.99) and test-retest reliability (R = 0.88). Both the validity (r = 0.10-0.52) and test-retest reliability (r = 0.61-0.78) were lower for the BESS. These findings demonstrate that a low-cost balance board can provide improved balance testing accuracy/reliability compared with the BESS. This approach provides a potentially more valid/reliable, yet affordable, means of assessing sports-related concussion compared with current methods.

  20. Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people

    Directory of Open Access Journals (Sweden)

    Boneth M

    2012-05-01

    Full Text Available Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3, on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95% respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.

  1. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults.

    Science.gov (United States)

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (pisometric strength provided reliable test-retest measures in healthy older adults. Ib.

  2. The Ostomy Adjustment Scale: translation into Norwegian language with validation and reliability testing.

    Science.gov (United States)

    Indrebø, Kirsten Lerum; Andersen, John Roger; Natvig, Gerd Karin

    2014-01-01

    The purpose of this study was to adapt the Ostomy Adjustment Scale to a Norwegian version and to assess its construct validity and 2 components of its reliability (internal consistency and test-retest reliability). One hundred fifty-eight of 217 patients (73%) with a colostomy, ileostomy, or urostomy participated in the study. Slightly more than half (56%) were men. Their mean age was 64 years (range, 26-91 years). All respondents had undergone ostomy surgery at least 3 months before participation in the study. The Ostomy Adjustment Scale was translated into Norwegian according to standard procedures for forward and backward translation. The questionnaire was sent to the participants via regular post. The Cronbach alpha and test-retest were computed to assess reliability. Construct validity was evaluated via correlations between each item and score sums; correlations were used to analyze relationships between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, the Hospital Anxiety & Depression Scale, and the General Self-Efficacy Scale. The Cronbach alpha was 0.93, and test-retest reliability r was 0.69. The average correlation quotient item to sum score was 0.49 (range, 0.31-0.73). Results showed moderate negative correlations between the Ostomy Adjustment Scale and the Hospital Anxiety and Depression Scale (-0.37 and -0.40), and moderate positive correlations between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, and the General Self-Efficacy Scale (0.30-0.45) with the exception of the pain domain in the Short Form 36 (0.28). Regression analysis showed linear associations between the Ostomy Adjustment Scale and sociodemographic and clinical variables with the exception of education. The Norwegian language version of the Ostomy Adjustment Scale was found to possess construct validity, along with internal consistency and test-retest reliability. The instrument is

  3. Acceptability, reliability, and validity of the Stroke and Aphasia Quality of Life Scale-39 (SAQOL-39) across languages: a systematic review.

    Science.gov (United States)

    Ahmadi, Akram; Tohidast, Seyed Abolfazl; Mansuri, Banafshe; Kamali, Mohammad; Krishnan, Gopee

    2017-09-01

    This systematic review aimed to explore the acceptability, reliability, and validity of the Stroke and Aphasia Quality of Life-39 (SAQOL-39) scale across languages. We employed a systematic search of the online databases including MEDLINE (Pubmed), Science direct, Web of science, Psychinfo, Scopus, ProQuest, Google Scholar, and Cochrane library published between 2003 and 2016. We used PRISMA guidelines for conducting and reporting this review. Subsequently, screening of the titles and abstracts, extraction of data as well as the appraisal of the quality of relevant studies were carried out. The initial search returned 8185 studies. Subsequent screening and study selection processes narrowed them to 20, needing detailed review. Forward-backward translation scheme was the preferred method for translation of the SAQOL-39 from English to other languages. Mainly, the socio-cultural and linguistic adaptations were performed in the translated versions. Most versions of the SAQOL-39 showed high test-retest reliability and internal consistency. However, several psychometric properties including the validity and responsiveness were seldom reported in these versions. The SAQOL-39 scale showed high acceptability, and reliability across the languages reviewed in this study. Future translations may additionally focus on reporting the validity and responsiveness of the instrument.

  4. Stability of FDG-PET Radiomics features - An integrated analysis of test-retest and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Leijenaar, Ralph T. H.; Carvalho, Sara; Rios Velazquez, Emmanuel [Dept. of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht Univ. Medical Center, Maastricht (Netherlands)] [and others

    2013-10-15

    Purpose: Besides basic measurements as maximum standardized uptake value (SUV){sub max} or SUV{sub mean} derived from 18F-FDG positron emission tomography (PET) scans, more advanced quantitative imaging features (i.e. 'Radiomics' features) are increasingly investigated for treatment monitoring, outcome prediction, or as potential biomarkers. With these prospected applications of Radiomics features, it is a requisite that they provide robust and reliable measurements. The aim of our study was therefore to perform an integrated stability analysis of a large number of PET-derived features in non-small cell lung carcinoma (NSCLC), based on both a test-retest and an inter-observer setup. Methods: Eleven NSCLC patients were included in the test-retest cohort. Patients underwent repeated PET imaging within a one day interval, before any treatment was delivered. Lesions were delineated by applying a threshold of 50 % of the maximum uptake value within the tumor. Twenty-three NSCLC patients were included in the inter-observer cohort. Patients underwent a diagnostic whole body PET-computed tomography (CT). Lesions were manually delineated based on fused PET-CT, using a standardized clinical delineation protocol. Delineation was performed independently by five observers, blinded to each other. Fifteen first order statistics, 39 descriptors of intensity volume histograms, eight geometric features and 44 textural features were extracted. For every feature, test-retest and inter-observer stability was assessed with the intra-class correlation coefficient (ICC) and the coefficient of variability, normalized to mean and range. Similarity between test-retest and inter-observer stability rankings of features was assessed with Spear man's rank correlation coefficient. Results: Results showed that the majority of assessed features had both a high test-retest (71%) and inter-observer (91%) stability in terms of their ICC. Overall, features more stable in repeated PET

  5. Test-retest reliability of pure-tone thresholds from 0.5 to 16 kHz using Sennheiser HDA 200 and Etymotic Research ER-2 earphones.

    Science.gov (United States)

    Schmuziger, Nicolas; Probst, Rudolf; Smurzynski, Jacek

    2004-04-01

    The purposes of the study were: (1) To evaluate the intrasession test-retest reliability of pure-tone thresholds measured in the 0.5-16 kHz frequency range for a group of otologically healthy subjects using Sennheiser HDA 200 circumaural and Etymotic Research ER-2 insert earphones and (2) to compare the data with existing criteria of significant threshold shifts related to ototoxicity and noise-induced hearing loss. Auditory thresholds in the frequency range from 0.5 to 6 kHz and in the extended high-frequency range from 8 to 16 kHz were measured in one ear of 138 otologically healthy subjects (77 women, 61 men; mean age, 24.4 yr; range, 12-51 yr) using HDA 200 and ER-2 earphones. For each subject, measurements of thresholds were obtained twice for both transducers during the same test session. For analysis, the extended high-frequency range from 8 to 16 kHz was subdivided into 8 to 12.5 and 14 to 16 kHz ranges. Data for each frequency and frequency range were analyzed separately. There were no significant differences in repeatability for the two transducer types for all frequency ranges. The intrasession variability increased slightly, but significantly, as frequency increased with the greatest amount of variability in the 14 to 16 kHz range. Analyzing each individual frequency, variability was increased particularly at 16 kHz. At each individual frequency and for both transducer types, intrasession test-retest repeatability from 0.5 to 6 kHz and 8 to 16 kHz was within 10 dB for >99% and >94% of measurements, respectively. The results indicated a false-positive rate of HDA 200. Repeatability was similar for both transducer types. Intrasession test-retest repeatability from 0.5 to 12.5 kHz at each individual frequency including the frequency range susceptible to noise-induced hearing loss was excellent for both transducers. Repeatability was slightly, but significantly poorer in the frequency range from 14 to 16 kHz compared with the frequency ranges from 0.5 to 6

  6. WRAP low level waste (LLW) glovebox acceptance test report

    International Nuclear Information System (INIS)

    Leist, K.J.

    1998-01-01

    In June 28, 1997, the Low Level Waste (LLW) glovebox was tested using glovebox acceptance test procedure 13031A-85. The primary focus of the glovebox acceptance test was to examine control system interlocks, display menus, alarms, and operator messages. Limited mechanical testing involving the drum ports, hoists, drum lifter, compacted drum lifter, drum tipper, transfer car, conveyors, lidder/delidder device and the supercompactor were also conducted. As of November 24, 1997, 2 of the 131 test exceptions that affect the LLW glovebox remain open. These items will be tracked and closed via the WRAP Master Test Exception Database. As part of Test Exception resolution/closure the responsible individual closing the Test Exception performs a retest of the affected item(s) to ensure the identified deficiency is corrected, and, or to test items not previously available to support testing. Test Exceptions are provided as appendices to this report

  7. W-026, transuranic waste (TRU) glovebox acceptance test report

    International Nuclear Information System (INIS)

    Leist, K.J.

    1998-01-01

    On July 18, 1997, the Transuranic (TRU) glovebox was tested using glovebox acceptance test procedure 13021A-86. The primary focus of the glovebox acceptance test was to examine control system interlocks, display menus, alarms, and operator messages. Limited mechanical testing involving the drum ports, hoists, drum lifter, compacted drum lifter, drum tipper, transfer car, conveyors, sorting table, lidder/delidder device and the TRU empty drum compactor were also conducted. As of February 25, 1998, 10 of the 102 test exceptions that affect the TRU glovebox remain open. These items will be tracked and closed via the WRAP Master Test Exception Database. As part of Test Exception resolution/closure the responsible individual closing the Test Exception performs a retest of the affected item(s) to ensure the identified deficiency is corrected, and, or to test items not previously available to support testing. Test exceptions are provided as appendices to this report

  8. WRAP low level waste (LLW) glovebox acceptance test report

    Energy Technology Data Exchange (ETDEWEB)

    Leist, K.J.

    1998-02-17

    In June 28, 1997, the Low Level Waste (LLW) glovebox was tested using glovebox acceptance test procedure 13031A-85. The primary focus of the glovebox acceptance test was to examine control system interlocks, display menus, alarms, and operator messages. Limited mechanical testing involving the drum ports, hoists, drum lifter, compacted drum lifter, drum tipper, transfer car, conveyors, lidder/delidder device and the supercompactor were also conducted. As of November 24, 1997, 2 of the 131 test exceptions that affect the LLW glovebox remain open. These items will be tracked and closed via the WRAP Master Test Exception Database. As part of Test Exception resolution/closure the responsible individual closing the Test Exception performs a retest of the affected item(s) to ensure the identified deficiency is corrected, and, or to test items not previously available to support testing. Test Exceptions are provided as appendices to this report.

  9. Feasibility and Reliability of Physical Fitness Tests in Older Adults with Intellectual Disability: A Pilot Study

    Science.gov (United States)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2012-01-01

    Background: Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods: Feasibility and test-retest reliability of a physical fitness test battery (Box and Block Test, Response Time Test, walking…

  10. Impact on participation and autonomy: test of validity and reliability for older persons

    Directory of Open Access Journals (Sweden)

    Isabelle Ottenvall Hammar

    2014-10-01

    Full Text Available In research and healthcare it is important to measure older persons’ self-determination in order to improve their possibilities to decide for themselves in daily life. The questionnaire Impact on Participation and Autonomy (IPA assesses self-determination, but is not constructed for older persons. The aim of this study was to examine the validity and reliability of the IPA-S questionnaire for persons aged 70 years and older. The study was performed in two steps; first a validity test of the Swedish version of the questionnaire, IPA-S, followed by a reliability test-retest of an adjusted version. The validity was tested with focus groups and individual interviews on persons aged 77-88 years, and the reliability on persons aged 70-99 years. The validity test result showed that IPA-S is valid for older persons but it was too extensive and the phrasing of the items needed adjustments. The reliability test-retest on the adjusted questionnaire, IPA-Older persons (IPA-O, showed that 15 of 22 items had high agreement. IPA-O can be used to measure older persons’ self-determination in their care and rehabilitation.

  11. Feasibility and reliability of physical fitness tests in older adults with intellectual disability : A pilot study

    NARCIS (Netherlands)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    Background Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods Feasibility and test-retest reliability of a physical fitness test battery

  12. Test-retest reliability of prefrontal transcranial Direct Current Stimulation (tDCS) effects on functional MRI connectivity in healthy subjects.

    Science.gov (United States)

    Wörsching, Jana; Padberg, Frank; Helbich, Konstantin; Hasan, Alkomiet; Koch, Lena; Goerigk, Stephan; Stoecklein, Sophia; Ertl-Wagner, Birgit; Keeser, Daniel

    2017-07-15

    Transcranial Direct Current Stimulation (tDCS) of the prefrontal cortex (PFC) can be used for probing functional brain connectivity and meets general interest as novel therapeutic intervention in psychiatric and neurological disorders. Along with a more extensive use, it is important to understand the interplay between neural systems and stimulation protocols requiring basic methodological work. Here, we examined the test-retest (TRT) characteristics of tDCS-induced modulations in resting-state functional-connectivity MRI (RS fcMRI). Twenty healthy subjects received 20minutes of either active or sham tDCS of the dorsolateral PFC (2mA, anode over F3 and cathode over F4, international 10-20 system), preceded and ensued by a RS fcMRI (10minutes each). All subject underwent three tDCS sessions with one-week intervals in between. Effects of tDCS on RS fcMRI were determined at an individual as well as at a group level using both ROI-based and independent-component analyses (ICA). To evaluate the TRT reliability of individual active-tDCS and sham effects on RS fcMRI, voxel-wise intra-class correlation coefficients (ICC) of post-tDCS maps between testing sessions were calculated. For both approaches, results revealed low reliability of RS fcMRI after active tDCS (ICC (2,1) = -0.09 - 0.16). Reliability of RS fcMRI (baselines only) was low to moderate for ROI-derived (ICC (2,1) = 0.13 - 0.50) and low for ICA-derived connectivity (ICC (2,1) = 0.19 - 0.34). Thus, for ROI-based analyses, the distribution of voxel-wise ICC was shifted to lower TRT reliability after active, but not after sham tDCS, for which the distribution was similar to baseline. The intra-individual variation observed here resembles variability of tDCS effects in motor regions and may be one reason why in this study robust tDCS effects at a group level were missing. The data can be used for appropriately designing large scale studies investigating methodological issues such as sources of variability and

  13. Test-retest reliability and validity of a web-based food-frequency questionnaire for adolescents aged 13-14 to be used in the Norwegian Mother and Child Cohort Study (MoBa).

    Science.gov (United States)

    Overby, Nina Cecilie; Johannesen, Elisabeth; Jensen, Grete; Skjaevesland, Anne-Kirsti; Haugen, Margaretha

    2014-01-01

    The assessment of food intake is challenging and prone to errors; it is therefore important to consider the reliability and validity of the assessment methods. The aim of this study was to analyze the reproducibility and validity of a developed food-frequency questionnaire (FFQ) for use among adolescents. In total, 58 students (aged 13-14) from four different schools in the southern part of Norway participated in the reproducibility study of filling out the FFQ 4 weeks apart. In addition, 93 students participated in the relative validity study where the FFQ was compared to 2×24-hour dietary recalls, while 92 students participated in the absolute validity study where the intakes of fatty acids and vitamin D from the FFQ were compared to fatty acids and 25-hydroxy-vitamin D3 in whole blood. The median Spearman correlation coefficient for all nutrients in the test-retest reliability study was 0.57. The median Spearman correlation for all nutrients in the relative validity study was 0.26, while the correlations coefficients were low in the absolute validity study with n-3 fatty acid coefficients ranging from 0.05 to 0.25, and absent for vitamin D (r=0.000). The test-retest reproducibility was considered good, the relative validity was considered poor to good, and the absolute validity was considered poor. However, the results are comparable to other studies among adolescents.

  14. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    Science.gov (United States)

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. A within-sample investigation of test–retest reliability in choice experiment surveys with real economic incentives

    DEFF Research Database (Denmark)

    Mørkbak, Morten Raun; Olsen, Søren Bøye

    2015-01-01

    In this paper, we investigate the level of agreement between respondents' choices in identical choice sets in a test-retest choice experiment for a market good with real economic incentives, thus investigating whether the incentivised CE method can be reliable and stable over time. Besides...... comparing choices, we also test for differences in preferences and error variance when a sample of respondents is given the exact same questionnaire twice, with a time lag of 2 weeks in between. Finally, we examine potential reasons and covariates explaining the level of agreement in choices across the 2...... weeks. Across four different tests, we find very good agreement between the two choice experiments - both with respect to overall choices and with respect to preferences. Furthermore, error variances do not differ significantly between the two surveys. The results also show that the larger the utility...

  16. Test–Retest Reliability and Concurrent Validity of an fMRI-Compatible Pneumatic Vibrator to Stimulate Muscle Proprioceptors.

    Science.gov (United States)

    Goossens, Nina; Janssens, Lotte; Pijnenburg, Madelon; Caeyenberghs, Karen; Van Rompuy, Charlotte; Meugens, Paul; Sunaert, Stefan; Brumagne, Simon

    Processing proprioceptive information in the brain is essential for optimal postural control and can be studied with proprioceptive stimulation, provided by muscle vibration, during functional magnetic resonance imaging (fMRI). Classic electromagnetic muscle vibrators, however, cannot be used in the high-strength magnetic field of the fMRI scanner. Pneumatic vibrators offer an fMRI-compatible alternative. However, whether these devices produce reliable and valid proprioceptive stimuli has not been investigated, although this is essential for these devices to be used in longitudinal research. Test–retest reliability and concurrent validity of the postural response to muscle vibration, provided by custom-made fMRI-compatible pneumatic vibrators, were assessed in a repeated-measures design. Mean center of pressure (CoP) displacements during, respectively, ankle muscle and back muscle vibration (45–60 Hz, 0.5 mm) provided by an electromagnetic and a pneumatic vibrator were measured in ten young healthy subjects. The test was repeated on the same day and again within one week. Intraclass correlation coefficients (ICC) were calculated to assess (a) intra- and interday reliability of the postural responses to, respectively, pneumatic and electromagnetic vibration, and (b) concurrent validity of the response to pneumatic compared to electromagnetic vibration. Test–retest reliability of mean CoP displacements during pneumatic vibration was good to excellent (ICCs = 0.64–0.90) and resembled that of responses to electromagnetic vibration (ICCs = 0.64–0.94). Concurrent validity of the postural effect of pneumatic vibration was good to excellent (ICCs = 0.63–0.95). In conclusion, the proposed fMRI-compatible pneumatic vibrator can be used with confidence to stimulate muscle spindles during fMRI to study central processing of proprioception.

  17. The Test-Retest Reliability OfTthe Onset Of Core And Vasti Eectromyographic Activity While Ascending And Descending Stairs In Healthy Controls Aand patellofemoral Pain Patients

    Directory of Open Access Journals (Sweden)

    Mohammad-Ali Sanjari

    2011-02-01

    Full Text Available Backgroundentity.It is hypothesized to result from abnormal patellar tracking caused by altered motorcontrol. Deficit in neuromotor control of the core may be a remote contributing factor to thedevelopment of PFP. Application of reliable EMG measures would be helpful to handle thistheory. Therefore, the purpose of this study was to determine the test-retest reliability of thecore and vasti EMG onsets, while ascending/descending stairs.: Patellofemoral pain (PFP is a common affliction and complex clinicalMethodsand Core EMG onsets during stair stepping were assessed two times a day. Intraclass correlationcoefficients (ICCs and standard errors of measurement (SEMs were calculated.: Ten males with PFP and ten healthy controls participated in this study. VastiResultsonsets of control cases (ICC 3,1 ≥ 0.70 except Quadratus Lumborum (QL which showeda moderate reliability (ICC for ascending=0.59 and for descending = 0.61. In controls,Vasti in both tasks showed the highest absolute reliability. During ascending, highreliability (ICC ≥ 0.70 in PFP group was demonstrated for all EMG onsets except Gluteusmaximus (GMAX and QL which showed a moderate reliability (ICC = 0.69 and 0.63 respectively.In this group while descending stairs, all EMG onsets showed high relativereliability (ICC ≥ 0.70. Moderate to high absolute reliability was obtained for onset timeswhile ascending/descending stairs in PFP group.: During both ascending/descending, high reliability was found for all EMGConclusionreliability.: Most EMG onsets during stair scending/descending had moderate to high

  18. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan

    Directory of Open Access Journals (Sweden)

    Moore AL

    2018-02-01

    Full Text Available Amy Lawson Moore, Terissa M Miller Gibson Institute of Cognitive Research, Colorado Springs, CO, USA Purpose: The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills.Methods: This study included 2,737 participants aged 5–85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test–retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement.Results: Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test–retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93.Conclusion: The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan. Keywords: testing, cognitive skills, memory, processing speed, visual processing, auditory processing

  19. Test-retest repeatability of strength capacity, aerobic power and pericranial tenderness of neck and shoulder muscles in children - relevant for tension-type headache

    Directory of Open Access Journals (Sweden)

    Tornøe B

    2013-08-01

    -Altman Plots; and by quantifying the variability. Results: The results showed an acceptable test-retest repeatability of isometric maximal voluntary contraction (ICC 0.90-0.97. The force steadiness measurements revealed a trend of systematic changes in the direction of neck flexion and need further examination in both healthy and ill children. The rate of force development, Total Tenderness Score, and prediction of VO2 max showed repeatability, with ICC 0.80-0.87. Conclusion: The measurements of strength capacity, aerobic power, and tenderness provide acceptable repeatability, suitable for research in children. Keywords: muscle strength, intratester reliability, cardiovascular fitness

  20. Rationale and design of REACT: a randomised controlled trial assessing the effectiveness of home-collection to increase chlamydia retesting and detect repeat positive tests.

    Science.gov (United States)

    Smith, Kirsty S; Hocking, Jane S; Chen, Marcus; Fairley, Christopher K; McNulty, Anna; Read, Phillip; Bradshaw, Catriona S; Tabrizi, Sepehr N; Wand, Handan; Saville, Marion; Rawlinson, William; Garland, Suzanne M; Donovan, Basil; Kaldor, John M; Guy, Rebecca

    2014-04-24

    Repeat infection with Chlamydia trachomatis is common and increases the risk of sequelae in women and HIV seroconversion in men who have sex with men (MSM). Despite guidelines recommending chlamydia retesting three months after treatment, retesting rates are low. We are conducting the first randomised controlled trial to assess the effectiveness of home collection combined with short message service (SMS) reminders on chlamydia retesting and reinfection rates in three risk groups. The REACT (retest after Chlamydia trachomatis) trial involves 600 patients diagnosed with chlamydia: 200 MSM, 200 women and 200 heterosexual men recruited from two Australian sexual health clinics where SMS reminders for retesting are routine practice. Participants will be randomised to the home group (3-month SMS reminder and home-collection) or the clinic group (3-month SMS reminder to return to the clinic). Participants in the home group will be given the choice of attending the clinic if they prefer. The mailed home-collection kit includes a self-collected vaginal swab (women), UriSWAB (Copan) for urine collection (heterosexual men), and UriSWAB plus rectal swab (MSM). The primary outcome is the retest rate at 1-4 months after a chlamydia diagnosis, and the secondary outcomes are: the repeat positive test rate; the reinfection rate; the acceptability of home testing with SMS reminders; and the cost effectiveness of home testing. Sexual behaviour data collected via an online survey at 4-5 months, and genotyping of repeat infections, will be used to discriminate reinfections from treatment failures. The trial will be conducted over two years. An intention to treat analysis will be conducted. This study will provide evidence about the effectiveness of home-collection combined with SMS reminders on chlamydia retesting, repeat infection and reinfection rates in three risk groups. The trial will determine client acceptability and cost effectiveness of this strategy. Australian and New

  1. Reliability and acceptability of the Multiple Sclerosis Quality of Life-29 questionnaire in an English-speaking cohort.

    Science.gov (United States)

    Baker, Georgina; Nair, Krishnan Padmakumari Sivaraman; Baster, Kathleen; Rosato, Rosalba; Solari, Alessandra

    2018-05-01

    Multiple Sclerosis Quality-of-Life Questionnaire-54 (MSQoL-54) is a disease-specific instrument for assessing health-related quality of life (HRQoL). Due to the number of items, the time taken to complete it is long. A shorter 29-item version, Multiple Sclerosis Quality-of-Life Questionnaire-29 (MSQoL-29) is yet to be evaluated in English. To assess reliability and acceptability of English version of MSQoL-29. Among 100 participants with MS who first completed both MSQoL-54 and MSQoL-29, 91 completed MSQoL-29 after 4-8 weeks. We looked for internal consistency (Cronbach's alpha), acceptability, reliability (intraclass correlation coefficients (ICCs)) and agreement (Bland-Altman plots). ICCs were strongly positive between MSQoL-54 and MSQoL-29 (Physical Health Composite (PHC) -ICC = 0.914, confidence interval (CI) = 0.872-0.942; Mental Health Composite (MHC) - ICC = 0.875, CI = 0.814-0.916) and between the two MSQoL-29 (PHC - ICC = 0.970, CI = 0.955-0.980; MHC - ICC = 0.937, CI = 0.904-0.958). On Bland-Altman plots, the MSQoL-29 scores of 95% of participants during two visits were within the limits of agreement (LOAs). Time taken to complete MSQoL-29 was 7.2 ± 2.9 minutes and MSQoL-54 was 19.79 ± 5.4 minutes ( p = 0.0001). MSQoL-29 has good test-retest reliability in English-speaking population and was quicker to complete.

  2. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  3. Psychometric Properties of the Chinese Version of the Acceptance of Chronic Health Conditions (Stoma) Scale for Patients With Stoma.

    Science.gov (United States)

    Lim, Siew Hoon; He, Hong-Gu; Chan, Sally Wai Chi

    Formation of a stoma is a common outcome in surgical treatment of colorectal cancer. A higher acceptance of stoma was shown to improve quality of life of patients. No instrument in Chinese is available that can be used to measure the acceptance of stoma among patients with colorectal cancer. The aims of this study were to translate and test the psychometric properties of Chinese version of Acceptance of Chronic Health Conditions (ACHC) (Stoma) scale. A sample of 100 Chinese-speaking patients with stoma was recruited from a public tertiary care hospital in Singapore. The scale was translated into Chinese and reviewed by an expert panel for semantic equivalence and content validity testing. Convergent validity was established by exploring correlations between scores of the Chinese version of the ACHC (Stoma) scale and those of the 5-level version of European Quality of Life Questionnaire-5 Dimensions. Reliability was assessed by internal consistency and test-retest reliability. The newly translated scale had high content validity (content validity index = 94%) and acceptable internal consistency (Cronbach's α = .846). The test-retest reliability was satisfactory with an intraclass coefficient of 0.997. A positive correlation was found between both scores on ACHC (Stoma) scale and EQ-5D utility score (r = 0.63, P Stoma) scale demonstrated satisfactory content validity, good convergent validity, and adequate internal consistency and stability. This scale can be used as a convenient screening tool in clinical settings to assess the level of acceptance in Chinese-speaking patients with stoma.

  4. Assessing intraindividual variability in sustained attention: reliability, relation to speed and accuracy, and practice effects

    Directory of Open Access Journals (Sweden)

    HAGEN C. FLEHMIG

    2007-06-01

    Full Text Available We investigated the psychometric properties of competing measures of sustained attention. 179 subjects were assessed twice within seven day's time with a test designed to measure sustained attention, or concentration, respectively. In addition to traditional performance indices [i.e., speed (MRT and accuracy (E%], we evaluated two intraindividual response time (RT variability measures: standard deviation (SDRT and coefficient of variation (CVRT. For the overall test, both indices were reliable. SDRT showed good to acceptable retest reliability for all subtests. For CVRT, retest reliability coefficients ranged from very good to not satisfactory. While the reversed-word recognition test proved highly reliable, the mental calculation test and the arrows test were not sufficiently reliable. CVRT was only slightly correlated but SDRT was highly correlated with MRT. In contrast to substantial practice gains for MRT, SDRT and E%, only CVRT proved to be stable. In conclusion, CVRT appears to be a potential index for assessing performance variability: it is reliable for the overall test, only moderately correlated with speed, and virtually not affected by practice. However, before applying CVRT in practical assessment settings, additional research is required to elucidate the impact of task-specific factors on the reliability of this performance measure.

  5. Development of a Tablet-based symbol digit modalities test for reliably assessing information processing speed in patients with stroke.

    Science.gov (United States)

    Tung, Li-Chen; Yu, Wan-Hui; Lin, Gong-Hong; Yu, Tzu-Ying; Wu, Chien-Te; Tsai, Chia-Yin; Chou, Willy; Chen, Mei-Hsiang; Hsieh, Ching-Lin

    2016-09-01

    To develop a Tablet-based Symbol Digit Modalities Test (T-SDMT) and to examine the test-retest reliability and concurrent validity of the T-SDMT in patients with stroke. The study had two phases. In the first phase, six experts, nine college students and five outpatients participated in the development and testing of the T-SDMT. In the second phase, 52 outpatients were evaluated twice (2 weeks apart) with the T-SDMT and SDMT to examine the test-retest reliability and concurrent validity of the T-SDMT. The T-SDMT was developed via expert input and college student/patient feedback. Regarding test-retest reliability, the practise effects of the T-SDMT and SDMT were both trivial (d=0.12) but significant (p≦0.015). The improvement in the T-SDMT (4.7%) was smaller than that in the SDMT (5.6%). The minimal detectable changes (MDC%) of the T-SDMT and SDMT were 6.7 (22.8%) and 10.3 (32.8%), respectively. The T-SDMT and SDMT were highly correlated with each other at the two time points (Pearson's r=0.90-0.91). The T-SDMT demonstrated good concurrent validity with the SDMT. Because the T-SDMT had a smaller practise effect and less random measurement error (superior test-retest reliability), it is recommended over the SDMT for assessing information processing speed in patients with stroke. Implications for Rehabilitation The Symbol Digit Modalities Test (SDMT), a common measure of information processing speed, showed a substantial practise effect and considerable random measurement error in patients with stroke. The Tablet-based SDMT (T-SDMT) has been developed to reduce the practise effect and random measurement error of the SDMT in patients with stroke. The T-SDMT had smaller practise effect and random measurement error than the SDMT, which can provide more reliable assessments of information processing speed.

  6. Cross-Cultural Translation, Adaptation and Reliability of the Danish M. D. Andeson Dysphagia Inventory (MDADI) in Patients with Head and Neck Cancer.

    Science.gov (United States)

    Hajdú, Sara Fredslund; Plaschke, Christina Caroline; Johansen, Christoffer; Dalton, Susanne Oksbjerg; Wessel, Irene

    2017-08-01

    The objectives were to translate and culturally adapt the M.D. Anderson Dysphagia Inventory (MDADI) into Danish and subsequently test the reliability of the Danish version. The MDADI was translated into Danish and cross culturally adapted through cognitive interviews. The final version was test-retest evaluated in a group of head and neck cancer (HNC) patients who responded to the questionnaire twice with a mean of eight days apart. Interclass correlation coefficient, Cronbach's alpha, floor and ceiling effects, standard error of measurement and minimal detectable change were investigated. Fourteen patients were interviewed on the comprehensibility of the Danish MDADI, and all found the questionnaire meaningful, easy to understand, non-offensive and to include relevant aspects of dysphagia related to HNC. Sixty-four patients were included in the test-retest study. Especially, one item in the emotional scale (E7) appeared to be often misinterpreted, and ceiling effects were found in all four subdomains (global, emotional, functional and physical). The four subdomains and the composite score showed acceptable test-retest reliability and internal consistency in a Danish population of HNC patients. The Danish MDADI is reliable in terms of internal consistency and test-retest reproducibility and can be used in assessing the health-related quality of life in head and neck cancer patients with dysphagia.

  7. Psychometric Properties of the Persian Version of the Social Anxiety - Acceptance and Action Questionnaire.

    Science.gov (United States)

    Soltani, Esmail; Bahrainian, Seyed Abdolmajid; Masjedi Arani, Abbas; Farhoudian, Ali; Gachkar, Latif

    2016-06-01

    Social anxiety disorder is often related to specific impairment or distress in different areas of life, including occupational, social and family settings. The purpose of the present study was to examine the psychometric properties of the persian version of the social anxiety-acceptance and action questionnaire (SA-AAQ) in university students. In this descriptive cross-sectional study, 324 students from Shahid Beheshti University of Medical Sciences participated via the cluster sampling method during year 2015. Factor analysis by the principle component analysis method, internal consistency analysis, and convergent and divergent validity were conducted to examine the validity of the SA-AAQ. To calculate the reliability of the SA-AAQ, Cronbach's alpha and test-retest reliability were used. The results from factor analysis by principle component analysis method yielded three factors that were named acceptance, action and non-judging of experience. The three-factor solution explained 51.82% of the variance. Evidence for the internal consistency of SA-AAQ was obtained via calculating correlations between SA-AAQ and its subscales. Support for convergent and discriminant validity of the SA-AAQ via its correlations with the acceptance and action questionnaire - II, social interaction anxiety scale, cognitive fusion questionnaire, believability of anxious feelings and thoughts questionnaire, valued living questionnaire and WHOQOL- BREF was obtained. The reliability of the SA-AAQ via calculating Cronbach's alpha and test-retest coefficients yielded values of 0.84 and 0.84, respectively. The Iranian version of the SA-AAQ has acceptable levels of psychometric properties in university students. The SA-AAQ is a valid and reliable measure to be utilized in research investigations and therapeutic interventions.

  8. Reliability of Maximal Strength Testing in Novice Weightlifters

    Science.gov (United States)

    Loehr, James A.; Lee, Stuart M. C.; Feiveson, Alan H.; Ploutz-Snyder, Lori L.

    2009-01-01

    The one repetition maximum (1RM) is a criterion measure of muscle strength. However, the reliability of 1RM testing in novice subjects has received little attention. Understanding this information is crucial to accurately interpret changes in muscle strength. To evaluate the test-retest reliability of a squat (SQ), heel raise (HR), and deadlift (DL) 1RM in novice subjects. Twenty healthy males (31 plus or minus 5 y, 179.1 plus or minus 6.1 cm, 81.4 plus or minus 10.6 kg) with no weight training experience in the previous six months participated in four 1RM testing sessions, with each session separated by 5-7 days. SQ and HR 1RM were conducted using a smith machine; DL 1RM was assessed using free weights. Session 1 was considered a familiarization and was not included in the statistical analyses. Repeated measures analysis of variance with Tukey fs post-hoc tests were used to detect between-session differences in 1RM (p.0.05). Test-retest reliability was evaluated by intraclass correlation coefficients (ICC). During Session 2, the SQ and DL 1RM (SQ: 90.2 }4.3, DL: 75.9 }3.3 kg) were less than Session 3 (SQ: 95.3 }4.1, DL: 81.5 plus or minus 3.5 kg) and Session 4 (SQ: 96.6 }4.0, DL: 82.4 }3.9 kg), but there were no differences between Session 3 and Session 4. HR 1RM measured during Session 2 (150.1 }3.7 kg) and Session 3 (152.5 }3.9 kg) were not different from one another, but both were less than Session 4 (157.5 }3.8 kg). The reliability (ICC) of 1RM measures for Sessions 2-4 were 0.88, 0.83, and 0.87, for SQ, HR, and DL, respectively. When considering only Sessions 3 and 4, the reliability was 0.93, 0.91, and 0.86 for SQ, HR, and DL, respectively. One familiarization session and 2 test sessions (for SQ and DL) were required to obtain excellent reliability (ICC greater than or equal to 0.90) in 1RM values with novice subjects. We were unable to attain this level of reliability following 3 HR testing sessions therefore additional sessions may be required to obtain an

  9. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  10. Reliability of intra-oral quantitative sensory testing (QST) in patients with atypical odontalgia and healthy controls - a multicentre study.

    Science.gov (United States)

    Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M

    2015-02-01

    The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.

  11. Measuring older adults' sedentary time: reliability, validity, and responsiveness.

    Science.gov (United States)

    Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville

    2011-11-01

    With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is

  12. Sensitivity, reliability and the effects of diurnal variation on a test battery of field usable upper limb fatigue measures.

    Science.gov (United States)

    Yung, Marcus; Wells, Richard P

    2017-07-01

    Fatigue has been linked to deficits in production quality and productivity and, if of long duration, work-related musculoskeletal disorders. It may thus be a useful risk indicator and design and evaluation tool. However, there is limited information on the test-retest reliability, the sensitivity and the effects of diurnal fluctuation on field usable fatigue measures. This study reports on an evaluation of 11 measurement tools and their 14 parameters. Eight measures were found to have test-retest ICC values greater than 0.8. Four measures were particularly responsive during an intermittent fatiguing condition. However, two responsive measures demonstrated rhythmic behaviour, with significant time effects from 08:00 to mid-afternoon and early evening. Action tremor, muscle mechanomyography and perceived fatigue were found to be most reliable and most responsive; but additional analytical considerations might be required when interpreting daylong responses of MMG and action tremor. Practitioner Summary: This paper presents findings from test-retest and daylong reliability and responsiveness evaluations of 11 fatigue measures. This paper suggests that action tremor, muscle mechanomyography and perceived fatigue were most reliable and most responsive. However, mechanomyography and action tremor may be susceptible to diurnal changes.

  13. The Persian version of phonological test of diagnostic evaluation articulation and phonology for Persian speaking children and investigating its validity and reliability

    Directory of Open Access Journals (Sweden)

    Talieh Zarifian

    2014-10-01

    Full Text Available Background and Aim: Speech and language pathologists (SLP often refer to phonological data as part of their assessment protocols in evaluating the communication skills of children. The aim of this study was to develop the Persian version of the phonological test in evaluating and diagnosing communication skills in Persian speaking children and to evaluate its validity and reliability.Methods: The Persian phonological test (PPT was conducted on 387 monolingual Persian speaking boys and girls (3-6 years of age who were selected from 12 nurseries in the northwest region of Tehran. Content validity ratio (CVR and content validity index (CVI were assessed by speechtherapists and linguists. Correlation between speech and language pathologists experts' opinions and Persian phonological test results in children with and without phonological disorders was evaluated to investigate the Persian phonological test validity. In addition, the Persian phonological test test-retest reliability was investigated.Results: Both content validity ratio and content validity index were found to be acceptable (CVR≥94.71 and CVI=97.35. The PPT validity was confirmed by finding a good correlation between s peech and language pathologists experts' opinions and Persian phonological test results ( r Kappa =0.73 and r Spearman =0.76. The percent of agreement between transcription and analyzing error patterns in test-retest (ranging from 86.27%-100% and score-rescore (ranging from 94.28%-100% showed that Persian phonological test had a very high reliability.Conclusion: The results of this study show that the Persian phonological test seems to be a suitable tool in evaluating phonological skills of Persian speaking children in clinical settings and research projects.

  14. Test–retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects

    International Nuclear Information System (INIS)

    Cutajar, Marica; Clayden, Jonathan D.; Clark, Christopher A.; Gordon, Isky

    2011-01-01

    Purpose: This study assessed test–retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Materials and methods: Seven healthy volunteers (age range, 19–31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR = 730 ms, TE = 73 ms and 2 b-values (0 and 400 s mm −2 ). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Results: Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Conclusion: Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable.

  15. Reliability of 4-meter and 10-meter walk tests after lower extremity surgery.

    Science.gov (United States)

    Unver, Bayram; Baris, Refik Hilmi; Yuksel, Ertugrul; Cekmece, Senol; Kalkan, Serpil; Karatosun, Vasfi

    2017-12-01

    To investigate the test-retest reliability of the 4-meter walk test (4 MWT) and 10-meter walk test (10 MWT) in patients undergoing lower extremity surgery during inpatient rehabilitation. In all, 102 patients with total hip arthroplasty (THA), total knee arthroplasty (TKA), lower extremity fracture (LEF) and soft tissue operation were recruited. Patients performed two 4 MWT and two 10 MWT trials on the same day. The same researcher performed all the measurements to avoid inter-rater variability. The 4 MWT and 10 MWT were shown to have excellent test-retest reliability. The ICCs for the 4 MWT and 10 MWT were found as 0.94 and 0.95, respectively. The SEMs for the 4 MWT and 10 MWT were 2.0 and 5.5 seconds, respectively. The smallest real difference at the 95% confidence level (SRD95) was 5.5 seconds for the 4 MWT and 12.2 seconds for 10 MWT and SRD95 percentage was 31.2 for the 4 MWT and 28.5 for the 10 MWT. Both the 4 MWT and the 10 MWT have excellent reliability in patients undergoing lower extremity surgery such as TKA, THA, LEF and soft tissue operation during inpatient rehabilitation. Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status, represent a real clinical change in rehabilitation process. Implications for Rehabilitation The 4 MWT and the 10 MWT are simple methods and were also shown to be reliable measurement methods in many patient groups. This study illustrates that the test-retest reliability of the 4 MWT and 10 MWT are excellent in patients undergoing lower extremity surgery during inpatient rehabilitation (ICC: 0.94 for 4 MWT, ICC: 0.95 for 10 MWT). Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status represent a real clinical change in rehabilitation process.

  16. Evidence of Reliability and Validity for a Children’s Auditory Continuous Performance Test

    Directory of Open Access Journals (Sweden)

    Michael J. Lasee

    2013-11-01

    Full Text Available Continuous Performance Tests (CPTs are commonly utilized clinical measures of attention and response inhibition. While there have been many studies of CPTs that utilize a visual format, there is considerably less research employing auditory CPTs. The current study provides initial reliability and validity evidence for the Auditory Vigilance Screening Measure (AVSM, a newly developed CPT. Participants included 105 five- to nine-year-old children selected from two rural Midwestern school districts. Reliability data for the AVSM was collected through retesting of 42 participants. Validity was evaluated through correlation of AVSM scales with subscales from the ADHD Rating Scale–IV. Test–retest reliability coefficients ranged from .62 to .74 for AVSM subscales. A significant (r = .31 correlation was obtained between the AVSM Impulsivity Scale and teacher ratings of inattention. Limitations and implications for future study are discussed.

  17. Retesting with the TRUE Test in a population-based twin cohort with hand eczema

    DEFF Research Database (Denmark)

    Lerbaek, Anne; Kyvik, Kirsten Ohm; Menné, Torkil

    2007-01-01

    Population-based studies on contact allergy with retesting of individuals are infrequently performed. Variable degrees of persistence are reported when individuals with contact allergy are retested with years in between. The patch test results of 270 individuals tested in 2005-2006 are presented ...

  18. Bayesian methodology for reliability model acceptance

    International Nuclear Information System (INIS)

    Zhang Ruoxue; Mahadevan, Sankaran

    2003-01-01

    This paper develops a methodology to assess the reliability computation model validity using the concept of Bayesian hypothesis testing, by comparing the model prediction and experimental observation, when there is only one computational model available to evaluate system behavior. Time-independent and time-dependent problems are investigated, with consideration of both cases: with and without statistical uncertainty in the model. The case of time-independent failure probability prediction with no statistical uncertainty is a straightforward application of Bayesian hypothesis testing. However, for the life prediction (time-dependent reliability) problem, a new methodology is developed in this paper to make the same Bayesian hypothesis testing concept applicable. With the existence of statistical uncertainty in the model, in addition to the application of a predictor estimator of the Bayes factor, the uncertainty in the Bayes factor is explicitly quantified through treating it as a random variable and calculating the probability that it exceeds a specified value. The developed method provides a rational criterion to decision-makers for the acceptance or rejection of the computational model

  19. Developing an acceptability assessment of preventive dental treatments.

    Science.gov (United States)

    Hyde, Susan; Gansky, Stuart A; Gonzalez-Vargas, Maria J; Husting, Sheila R; Cheng, Nancy F; Millstein, Susan G; Adams, Sally H

    2009-01-01

    Early childhood caries (ECC) is very prevalent among young Hispanic children. ECC is amenable to a variety of preventive procedures, yet many Hispanic families underutilize dental services. Acceptability research may assist in health care planning and resource allocation by identifying patient preferences among efficacious treatments with the goal of improving their utilization. The purposes of this study were (a) to develop a culturally competent acceptability assessment instrument, directed toward the caregivers of young Hispanic children, for five preventive dental treatments for ECC and (b) to test the instrument's reliability and validity. An instrument of five standard treatments known to prevent ECC was developed, translated, reviewed by focus groups, and pilot tested, then tested for reliability The instrument included illustrated cards, brief video clips, and samples of the treatments and was culturally appropriate for low-income Hispanic caregivers. In addition to determining the acceptability of the five treatments individually, the treatments were also presented as paired comparisons. Focus groups and debriefing interviews following the pilot tests established that the instrument has good face validity. The illustrated cards, product samples, and video demonstrations of the five treatments resulted in an instrument possessing good content validity. The instrument has good to excellent test-retest reliability, with identical time 1-time 2 responses for each of the five treatments 92 percent of the time (range 87 to 97 percent), and the same treatment of the paired comparisons preferred 75 percent of the time (range 61 to 90 percent). The acceptability instrument described is reliable and valid and may be useful in program planning efforts to identify and increase the utilization of preferred ECC preventive treatments for target populations.

  20. Reliability of the Cooking Task in adults with acquired brain injury.

    Science.gov (United States)

    Poncet, Frédérique; Swaine, Bonnie; Taillefer, Chantal; Lamoureux, Julie; Pradat-Diehl, Pascale; Chevignard, Mathilde

    2015-01-01

    Acquired brain injury (ABI) often leads to deficits in executive functioning (EF) responsible for severe and long-standing disabilities in daily life activities. The Cooking Task is an ecological and valid test of EF involving multi-tasking in a real environment. Given its complex scoring system, it is important to establish the tool's reliability. The objective of the study was to examine the reliability of the Cooking Task (internal consistency, inter-rater and test-retest reliability). A total of 160 patients with ABI (113 men, mean age 37 years, SD = 14.3) were tested using the Cooking Task. For test-retest reliability, patients were assessed by the same rater on two occasions (mean interval 11 days) while two raters independently and simultaneously observed and scored patients' performances to estimate inter-rater reliability. Internal consistency was high for the global scale (Cronbach α = .74). Inter-rater reliability (n = 66) for total errors was also high (ICC = .93), however the test-retest reliability (n = 11) was poor (ICC = .36). In general the Cooking Task appears to be a reliable tool. The low test-retest results were expected given the importance of EF in the performance of novel tasks.

  1. Intertester reliability of the talk test in a cardiac rehabilitation population

    DEFF Research Database (Denmark)

    Petersen, Annemette Krintel; Maribo, Thomas; Hjortdal, Vibeke Elisabeth

    2013-01-01

    PURPOSE: The validity of the Talk Test (TT) is well documented, but the reliability of the test is not clear. The aim of this study was to assess the absolute and relative intertester reliability of the TT in cardiac patients. METHODS: Cardiac patients (n = 64) who had completed an exercise...... randomized to tests. Workload in watts at the first negative stage of the TT was registered as the test result. Patients and physiotherapists were blinded to test results of the first test. Absolute reliability of the TT was assessed with Bland-Altman plot, standard error of measurement, and minimal...... detectable change. Relative reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS: Mean difference in peak workload between test and retest was 0.8 W (95% CI: -4.8 to 3.3). Limit of agreement was estimated to be +31/-32 W. Standard error of measurement was 11 W (95% CI: 10...

  2. Test your memory-Turkish version (TYM-TR): reliability and validity study of a cognitive screening test.

    Science.gov (United States)

    Maviş, Ilknur; Özbabalik Adapinar, Belgin Demet; Yenilmez, Çinar; Aydin, Ayşe; Olgun, Engin; Bal, Cengiz

    2015-01-01

    The test your memory (TYM) is reported to be a sensitive cognitive function assessment scale for people with dementia. The aim of the present study was to investigate the reliability and validity of an adapted Turkish version of the TYM (TYM-TR) among Turkish dementia patients. The TYM-TR was given to 59 patients with dementia aged 60+ and 336 normal controls aged 23-75+. The diagnostic utility of the TYM-TR was compared with that of the mini-mental state examination (MMSE) to validate it. The internal consistency of the TYM-TR was a = 0.85. The test-retest reliability was 0.97 (P reliability and validity to distinguish dementia in the Turkish population.

  3. Validity and test–retest reliability of the Persian version of the Montgomery–Asberg Depression Rating Scale

    Directory of Open Access Journals (Sweden)

    Ahmadpanah M

    2016-03-01

    Full Text Available Mohammad Ahmadpanah,1 Meisam Sheikhbabaei,1 Mohammad Haghighi,1 Fatemeh Roham,1 Leila Jahangard,1 Amineh Akhondi,2 Dena Sadeghi Bahmani,3 Hafez Bajoghli,4 Edith Holsboer-Trachsler,3 Serge Brand3,5 1Behavioral Disorders and Substances Abuse Research Center, Hamadan University of Medical Sciences, Hamadan, Iran; 2Hamadan Educational Organization, Ministry of Education, Hamadan, Iran; 3Center for Affective, Stress, and Sleep Disorders, Psychiatric Clinics of the University of Basel, Basel, Switzerland; 4Iranian National Center for Addiction Studies (INCAS, Tehran University of Medical Sciences, Tehran, Iran; 5Department of Sport, Exercise and Health Science, Sport Science Section, University of Basel, Basel, Switzerland Background and aims: The Montgomery–Asberg Depression Rating Scale (MADRS is an expert’s rating tool to assess the severity and symptoms of depression. The aim of the present two studies was to validate the Persian version of the MADRS and determine its test–retest reliability in patients diagnosed with major depressive disorders (MDD. Methods: In study 1, the translated MADRS and the Hamilton Depression Rating Scale (HDRS were applied to 210 patients diagnosed with MDD and 100 healthy adults. In study 2,200 patients diagnosed with MDD were assessed with the MADRS in face-to-face interviews. Thereafter, 100 patients were assessed 3–14 days later, again via face-to-face-interviews, while the other 100 patients were assessed 3–14 days later via a telephone interview. Results: Study 1: The MADRS and HDRS scores between patients with MDD and healthy controls differed significantly. Agreement between scoring of the MADRS and HDRS was high (r=0.95. Study 2: The intraclass correlation coefficient (test–retest reliability was r=0.944 for the face-to-face interviews, and r=0.959 for the telephone interviews. Conclusion: The present data suggest that the Persian MADRS has high validity and excellent test–retest reliability over

  4. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review

    NARCIS (Netherlands)

    Ratter, Julia; Radlinger, Lorenz; Lucas, Cees

    2014-01-01

    Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue

  5. Good validity and reliability of the forgotten joint score in evaluating the outcome of total knee arthroplasty

    DEFF Research Database (Denmark)

    Thomsen, Morten G; Latifi, Roshan; Kallemose, Thomas

    2016-01-01

    . We investigated the validity and reliability of the FJS. Patients and methods - A Danish version of the FJS questionnaire was created according to internationally accepted standards. 360 participants who underwent primary TKA were invited to participate in the study. Of these, 315 were included...... in a validity study and 150 in a reliability study. Correlation between the Oxford knee score (OKS) and the FJS was examined and test-retest evaluation was performed. A ceiling effect was defined as participants reaching a score within 15% of the maximum achievable score. Results - The validity study revealed...... of the FJS (ICC? 0.79). We found a high level of internal consistency (Cronbach's? = 0.96). The ceiling effect for the FJS was 16%, as compared to 37% for the OKS. Interpretation - The FJS showed good construct validity and test-retest reliability. It had a lower ceiling effect than the OKS. The FJS appears...

  6. Test-retest reliability and sensitivity of the 20-meter walk test among patients with knee osteoarthritis.

    Science.gov (United States)

    Motyl, Jillian M; Driban, Jeffrey B; McAdams, Erica; Price, Lori Lyn; McAlindon, Timothy E

    2013-05-10

    The 20-meter walk test is a physical function measure commonly used in clinical research studies and rehabilitation clinics to measure gait speed and monitor changes in patients' physical function over time. Unfortunately, the reliability and sensitivity of this walk test are not well defined and, therefore, limit our ability to evaluate real changes in gait speed not attributable to normal variability. The aim of this study was to assess the test-restest reliability and sensitivity of the 20-meter walk test, at a self-selected pace, among patients with mild to moderate knee osteoarthritis (OA) and to suggest a standardized protocol for future test administration. This was a measurement reliability study. Fifteen consecutive people enrolled in a randomized-controlled trial of intra-articular corticosteroid injections for knee OA participated in this study. All participants completed 4 trials on 2 separate days, 7 to 21 days apart (8 trials total). Each day was divided into 2 sessions, which each involved 2 walking trials. We compared walk times between trials with Wilcoxon signed-rank tests. Similar analyses compared average walk times between sessions. To confirm these analyses, we also calculated Spearman correlation coefficients to assess the relationship between sessions. Finally, smallest detectable differences (SDD) were calculated to estimate the sensitivity of the 20-meter walk test. Wilcoxon signed-rank tests between trials within the same session demonstrated that trials in session 1 were significantly different and in the subsequent 3 sessions, the median differences between trials were not significantly different. Therefore, the first session of each day was considered a practice session, and the SDD between the second session of each day were calculated. SDD was -1.59 seconds (walking slower) and 0.15 seconds (walking faster). Practice trials and a standardized protocol should be used in administration of the 20-meter walk test. Changes in walk time

  7. Development and reliability testing of a self-report instrument to measure the office layout as a correlate of occupational sitting

    Directory of Open Access Journals (Sweden)

    Duncan Mitch J

    2013-02-01

    Full Text Available Abstract Background Spatial configurations of office environments assessed by Space Syntax methodologies are related to employee movement patterns. These methods require analysis of floors plans which are not readily available in large population-based studies or otherwise unavailable. Therefore a self-report instrument to assess spatial configurations of office environments using four scales was developed. Methods The scales are: local connectivity (16 items, overall connectivity (11 items, visibility of co-workers (10 items, and proximity of co-workers (5 items. A panel cohort (N = 1154 completed an online survey, only data from individuals employed in office-based occupations (n = 307 were used to assess scale measurement properties. To assess test-retest reliability a separate sample of 37 office-based workers completed the survey on two occasions 7.7 (±3.2 days apart. Redundant scale items were eliminated using factor analysis; Chronbach’s α was used to evaluate internal consistency and test re-test reliability (retest-ICC. ANOVA was employed to examine differences between office types (Private, Shared, Open as a measure of construct validity. Generalized Linear Models were used to examine relationships between spatial configuration scales and the duration of and frequency of breaks in occupational sitting. Results The number of items on all scales were reduced, Chronbach’s α and ICCs indicated good scale internal consistency and test re-test reliability: local connectivity (5 items; α = 0.70; retest-ICC = 0.84, overall connectivity (6 items; α = 0.86; retest-ICC = 0.87, visibility of co-workers (4 items; α = 0.78; retest-ICC = 0.86, and proximity of co-workers (3 items; α = 0.85; retest-ICC = 0.70. Significant (p ≤ 0.001 differences, in theoretically expected directions, were observed for all scales between office types, except overall connectivity. Significant associations were

  8. A reliability analysis of the revised competitiveness index.

    Science.gov (United States)

    Harris, Paul B; Houston, John M

    2010-06-01

    This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.

  9. Dynamic control of the lumbopelvic complex; lack of reliability of established test procedures

    DEFF Research Database (Denmark)

    Henriksen, Marius; Lund, Hans; Bliddal, Henning

    2007-01-01

    used in order to account for learning effects. Intraclass correlation coefficients were low for the sitting (0.54) and supported standing positions (0.36). In the standing position, a significant difference between test and retest was observed (P = 0.003) and further reliability analysis was therefore...

  10. Reliability of a science admission test (HAM-Nat) at Hamburg medical school.

    Science.gov (United States)

    Hissbach, Johanna; Klusmann, Dietrich; Hampe, Wolfgang

    2011-01-01

    The University Hospital in Hamburg (UKE) started to develop a test of knowledge in natural sciences for admission to medical school in 2005 (Hamburger Auswahlverfahren für Medizinische Studiengänge, Naturwissenschaftsteil, HAM-Nat). This study is a step towards establishing the HAM-Nat. We are investigating parallel forms reliability, the effect of a crash course in chemistry on test results, and correlations of HAM-Nat test results with a test of scientific reasoning (similar to a subtest of the "Test for Medical Studies", TMS). 316 first-year students participated in the study in 2007. They completed different versions of the HAM-Nat test which consisted of items that had already been used (HN2006) and new items (HN2007). Four weeks later half of the participants were tested on the HN2007 version of the HAM-Nat again, while the other half completed the test of scientific reasoning. Within this four week interval students were offered a five day chemistry course. Parallel forms reliability for four different test versions ranged from r(tt)=.53 to r(tt)=.67. The retest reliabilities of the HN2007 halves were r(tt)=.54 and r(tt )=.61. Correlations of the two HAM-Nat versions with the test of scientific reasoning were r=.34 und r=.21. The crash course in chemistry had no effect on HAM-Nat scores. The results suggest that further versions of the test of natural sciences will not easily conform to the standards of internal consistency, parallel-forms reliability and retest reliability. Much care has to be taken in order to assemble items which could be used interchangeably for the construction of new test versions. The test of scientific reasoning and the HAM-Nat are tapping different constructs. Participation in a chemistry course did not improve students' achievement, probably because the content of the course was not coordinated with the test and many students lacked of motivation to do well in the second test.

  11. Is the conditioned pain modulation paradigm reliable? A test-retest assessment using the nociceptive withdrawal reflex.

    Directory of Open Access Journals (Sweden)

    José A Biurrun Manresa

    Full Text Available The aim of this study was to determine the reliability of the conditioned pain modulation (CPM paradigm assessed by an objective electrophysiological method, the nociceptive withdrawal reflex (NWR, and psychophysical measures, using hypothetical sample sizes for future studies as analytical goals. Thirty-four healthy volunteers participated in two identical experimental sessions, separated by 1 to 3 weeks. In each session, the cold pressor test (CPT was used to induce CPM, and the NWR thresholds, electrical pain detection thresholds and pain intensity ratings after suprathreshold electrical stimulation were assessed before and during CPT. CPM was consistently detected by all methods, and the electrophysiological measures did not introduce additional variation to the assessment. In particular, 99% of the trials resulted in higher NWR thresholds during CPT, with an average increase of 3.4 mA (p<0.001. Similarly, 96% of the trials resulted in higher electrical pain detection thresholds during CPT, with an average increase of 2.2 mA (p<0.001. Pain intensity ratings after suprathreshold electrical stimulation were reduced during CPT in 84% of the trials, displaying an average decrease of 1.5 points in a numeric rating scale (p<0.001. Under these experimental conditions, CPM reliability was acceptable for all assessment methods in terms of sample sizes for potential experiments. The presented results are encouraging with regards to the use of the CPM as an assessment tool in experimental and clinical pain. Trial registration: Clinical Trials.gov NCT01636440.

  12. CERN Technical training 2008 - Learning for the LHC: Special Workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrates that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the electro...

  13. CERN Technical training 2008 - Learning for the LHC: Special Workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrate that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of the utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the elec...

  14. CERN Technical training 2008 - Learning for the LHC: Special workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrate that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of the utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the elec...

  15. Inter-rater and test–retest reliability of quality assessments by novice student raters using the Jadad and Newcastle–Ottawa Scales

    Science.gov (United States)

    Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C

    2012-01-01

    Introduction Quality assessment of included studies is an important component of systematic reviews. Objective The authors investigated inter-rater and test–retest reliability for quality assessments conducted by inexperienced student raters. Design Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle–Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13–20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. Setting McMaster Integrative Neuroscience Discovery and Study Program. Participants 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. Main outcome measures The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test–retest reliability using ICC(2,1). Results Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI −0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were −0.14 (95% CI −0.28 to 0.00) to 0.39 (95% CI −0.02 to 0.81) for the NOS cohort and −0.20 (95% CI −0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case–control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test–retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were −0.19 (95% CI −0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case–control, the ICC(2

  16. Smallest detectable change and test-retest reliability of a self-reported outcome measure: Results of the Center for Epidemiologic Studies Depression Scale, General Self-Efficacy Scale, and 12-item General Health Questionnaire.

    Science.gov (United States)

    Ohno, Shotaro; Takahashi, Kana; Inoue, Aimi; Takada, Koki; Ishihara, Yoshiaki; Tanigawa, Masaru; Hirao, Kazuki

    2017-12-01

    This study aims to examine the smallest detectable change (SDC) and test-retest reliability of the Center for Epidemiologic Studies Depression Scale (CES-D), General Self-Efficacy Scale (GSES), and 12-item General Health Questionnaire (GHQ-12). We tested 154 young adults at baseline and 2 weeks later. We calculated the intra-class correlation coefficients (ICCs) for test-retest reliability with a two-way random effects model for agreement. We then calculated the standard error of measurement (SEM) for agreement using the ICC formula. The SEM for agreement was used to calculate SDC values at the individual level (SDC ind ) and group level (SDC group ). The study participants included 137 young adults. The ICCs for all self-reported outcome measurement scales exceeded 0.70. The SEM of CES-D was 3.64, leading to an SDC ind of 10.10 points and SDC group of 0.86 points. The SEM of GSES was 1.56, leading to an SDC ind of 4.33 points and SDC group of 0.37 points. The SEM of GHQ-12 with bimodal scoring was 1.47, leading to an SDC ind of 4.06 points and SDC group of 0.35 points. The SEM of GHQ-12 with Likert scoring was 2.44, leading to an SDC ind of 6.76 points and SDC group of 0.58 points. To confirm that the change was not a result of measurement error, a score of self-reported outcome measurement scales would need to change by an amount greater than these SDC values. This has important implications for clinicians and epidemiologists when assessing outcomes. © 2017 John Wiley & Sons, Ltd.

  17. Reliability and validity of television food advertising questionnaire in Malaysia.

    Science.gov (United States)

    Zalma, Abdul Razak; Safiah, Md Yusof; Ajau, Danis; Khairil Anuar, Md Isa

    2015-09-01

    Interventions to counter the influence of television food advertising amongst children are important. Thus, reliable and valid instrument to assess its effect is needed. The objective of this study was to determine the reliability and validity of such a questionnaire. The questionnaire was administered twice on 32 primary schoolchildren aged 10-11 years in Selangor, Malaysia. The interval between the first and second administration was 2 weeks. Test-retest method was used to examine the reliability of the questionnaire. Intra-rater reliability was determined by kappa coefficient and internal consistency by Cronbach's alpha coefficient. Construct validity was evaluated using factor analysis. The test-retest correlation showed moderate-to-high reliability for all scores (r = 0.40*, p = 0.02 to r = 0.95**, p = 0.00), with one exception, consumption of fast foods (r = 0.24, p = 0.20). Kappa coefficient showed acceptable-to-strong intra-rater reliability (K = 0.40-0.92), except for two items under knowledge on television food advertising (K = 0.26 and K = 0.21) and one item under preference for healthier foods (K = 0.33). Cronbach's alpha coefficient indicated acceptable internal consistency for all scores (0.45-0.60). After deleting two items under Consumption of Commonly Advertised Food, the items showed moderate-to-high loading (0.52, 0.84, 0.42 and 0.42) with the Scree plot showing that there was only one factor. The Kaiser-Meyer-Olkin was 0.60, showing that the sample was adequate for factor analysis. The questionnaire on television food advertising is reliable and valid to assess the effect of media literacy education on television food advertising on schoolchildren. © The Author (2013). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Test--retest variability of Randot stereoacuity measures gathered in an unselected sample of UK primary school children.

    Science.gov (United States)

    Adler, Paul; Scally, Andrew J; Barrett, Brendan T

    2012-05-01

    To determine the test-retest reliability of the Randot stereoacuity test when used as part of vision screening in schools. Randot stereoacuity (graded-circles) and logMAR visual acuity measures were gathered in an unselected sample of 139 children (aged 4-12, mean 8.1±2.1 years) in two schools. Randot testing was repeated on two occasions (average interval between successive tests 8 days, range: 1-21 days). Three Randot scores were obtained in 97.8% of children. Randot stereoacuity improved by an average of one plate (ie, one test level) on repeat testing but was little changed when tested on the third occasion. Within-subject variability was up to three test levels on repeat testing. When stereoacuity was categorised as 'fine', 'intermediate' or 'coarse', the greatest variability was found among younger children who exhibited 'intermediate' or 'coarse'/nil stereopsis on initial testing. Whereas 90.8% of children with 'fine' stereopsis (≤50 arc-seconds) on the first test exhibited 'fine' stereopsis on both subsequent tests, only ∼16% of children with 'intermediate' (>50 but ≤140 arc-seconds) or 'coarse'/nil (≥200 arc-seconds) stereoacuity on initial testing exhibited stable test results on repeat testing. Children exhibiting abnormal stereoacuity on initial testing are very likely to exhibit a normal result when retested. The value of a single, abnormal Randot graded-circles stereoacuity measure from school screening is therefore questionable.

  19. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review

    Directory of Open Access Journals (Sweden)

    Julia Ratter

    2014-09-01

    [Ratter J, Radlinger L, Lucas C (2014 Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review. Journal of Physiotherapy 60: 144–150

  20. Development of a Saudi Food Frequency Questionnaire and testing its reliability and validity.

    Science.gov (United States)

    Gosadi, Ibrahim M; Alatar, Abdullah A; Otayf, Mojahed M; AlJahani, Dhaherah M; Ghabbani, Hisham M; AlRajban, Waleed A; Alrsheed, Abdullah M; Al-Nasser, Khalid A

    2017-06-01

    To create a food frequency questionnaire specifically designed to capture the dietary habits of Saudis and test its validity and reliability. Methods: This investigation is a longitudinal, test-retest study conducted in King Saud University, Riyadh, Kingdom of Saudi Arabia between December 2015 and March 2016. A list of 140 food items was included in the questionnaire where a closed-ended and open-ended approach was used. Regarding past   year food frequency consumption and 24 hours dietary recall, body weight and height were collected. Internal consistency, test-retest reliability, completeness of the food list, and criterion validity were assessed. Results: One-hundred and thirty eight participants were interviewed to complete the 24 hours dietary recall and the constructed questionnaire. Approximately 85% of the food items reported in the dietary recall were covered in the food frequency questionnaire. The association of body mass index with meats (regression coefficients: 2.28) and dairy products consumption frequency was statistically significant (regression coefficients: 2.31). A high overall reproducibility rate of the questionnaire was detected (Pearsons' correlation coefficient: 0.78 p less than 0.001).  Conclusion: The developed questionnaire has a high reliability and reasonable validity, and suitable for use in nutritional epidemiological investigations in Saudi Arabia.

  1. Test-retest reliability of myofascial trigger point detection in hip and thigh areas.

    Science.gov (United States)

    Rozenfeld, E; Finestone, A S; Moran, U; Damri, E; Kalichman, L

    2017-10-01

    Myofascial trigger points (MTrP's) are a primary source of pain in patients with musculoskeletal disorders. Nevertheless, they are frequently underdiagnosed. Reliable MTrP palpation is the necessary for their diagnosis and treatment. The few studies that have looked for intra-tester reliability of MTrPs detection in upper body, provide preliminary evidence that MTrP palpation is reliable. Reliability tests for MTrP palpation on the lower limb have not yet been performed. To evaluate inter- and intra-tester reliability of MTrP recognition in hip and thigh muscles. Reliability study. 21 patients (15 males and 6 females, mean age 21.1 years) referred to the physical therapy clinic, 10 with knee or hip pain and 11 with pain in an upper limb, low back, shin or ankle. Two experienced physical therapists performed the examinations, blinded to the subjects' identity, medical condition and results of the previous MTrP evaluation. Each subject was evaluated four times, twice by each examiner in a random order. Dichotomous findings included a palpable taut band, tenderness, referred pain, and relevance of referred pain to patient's complaint. Based on these, diagnosis of latent MTrP's or active MTrP's was established. The evaluation was performed on both legs and included a total of 16 locations in the following muscles: rectus femoris (proximal), vastus medialis (middle and distal), vastus lateralis (middle and distal) and gluteus medius (anterior, posterior and distal). Inter- and intra-tester reliability (Cohen's kappa (κ)) values for single sites ranged from -0.25 to 0.77. Median intra-tester reliability was 0.45 and 0.46 for latent and active MTrP's, and median inter-tester reliability was 0.51 and 0.64 for latent and active MTrPs, respectively. The examination of the distal vastus medialis was most reliable for latent and active MTrP's (intra-tester k = 0.27-0.77, inter-tester k = 0.77 and intra-tester k = 0.53-0.72, inter-tester k = 0.72, correspondingly

  2. Validation of the Spanish version of the Chronic Pain Acceptance Questionnaire (CPAQ for the assessment of acceptance in fibromyalgia

    Directory of Open Access Journals (Sweden)

    Luciano Juan V

    2010-04-01

    Full Text Available Abstract Background The aim of this study was to validate a Spanish version of the Chronic Pain Acceptance Questionnaire (CPAQ. Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. The Chronic Pain Acceptance Questionnaire (CPAQ is the questionnaire most often used to measure pain acceptance in chronic pain populations. Methods A total of 205 Spanish patients diagnosed with fibromyalgia syndrome who attended our pain clinic were asked to complete a battery of psychometric instruments: the Pain Visual Analogue Scale (PVAS for pain intensity, the Hospital Anxiety and Depression Scale (HADS, the Medical Outcome Study Short Form 36 (SF-36, the Pain Catastrophising Scale (PCS and the Fibromyalgia Impact Questionnaire (FIQ. Results Analysis of results showed that the Spanish CPAQ had good test-retest reliability (intraclass correlation coefficient 0.83 and internal consistency reliability (Cronbach's α: 0.83. The Spanish CPAQ score significantly correlated with pain intensity, anxiety, depression, pain catastrophising, health status and physical and psychosocial disability. The Scree plot and a Principal Components Factor analysis confirmed the same two-factor construct as the original English CPAQ. Conclusion The Spanish CPAQ is a reliable clinical assessment tool with valid construct validity for the acceptance measurement among a sample of Spanish fibromyalgia patients. This study will make it easier to assess pain acceptance in Spanish populations with fibromyalgia.

  3. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    Science.gov (United States)

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; pGERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  4. INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.

    Science.gov (United States)

    Riemann, Bryan L; Davis, Sarah E; Huet, Kevin; Davies, George J

    2016-02-01

    Based on the frequency pushing and pulling patterns are used in functional activities, there is a need to establish an objective method of quantifying the muscle performance characteristics associated with these motions, particularly during the later stages of rehabilitation as criteria for discharge. While isokinetic assessment offers an approach to quantifying muscle performance, little is known about closed kinetic chain (CKC) isokinetic testing of the upper extremity (UE). To determine the intersession reliability of isokinetic upper extremity measurement of pushing and pulling peak force and average power at slow (0.24 m/s), medium (0.43 m/s) and fast (0.61 m/s) velocities in healthy young adults. The secondary purpose was to compare pushing and pulling peak force (PF) and average power (AP) between the upper extremity limbs (dominant, non-dominant) across the three velocities. Twenty-four physically active men and women completed a test-retest (>96 hours) protocol in order to establish isokinetic UE CKC reliability of PF and AP during five maximal push and pull repetitions at three velocities. Both limb and speed orders were randomized between subjects. High test-retest relative reliability using intraclass correlation coefficients (ICC2, 1) were revealed for PF (.91-.97) and AP (.85-.95) across velocities, limbs and directions. PF typical error (% coefficient of variation) ranged from 6.1% to 11.3% while AP ranged from 9.9% to 26.7%. PF decreased significantly (p pushing were significantly greater than pulling at all velocities, however the push-pull differences in PF became less as velocity increased. There were no significant differences identified between the dominant and nondominant limbs. Isokinetically derived UE CKC push-pull PF and AP are reliable measures. The lack of limb differences in healthy normal participants suggests that clinicians can consider bilateral comparisons when interpreting test performance. The increase in pushing PF and

  5. Feasibility and Reliability of Two Different Walking Tests in People With Severe Intellectual and Sensory Disabilities

    NARCIS (Netherlands)

    Waninge, Aly; Evenhuis, I.E.; Van Wijck, R.; van der Schans, Cees

    2011-01-01

    Background  The purpose of this study is to describe feasibility and test–retest reliability of the six-minute walking distance test (6MWD) and an adapted shuttle run test (aSRT) in persons with severe intellectual and sensory (multiple) disabilities. Materials and Methods  Forty-seven persons with

  6. Reliability and convergent validity of the five-step test in people with chronic stroke.

    Science.gov (United States)

    Ng, Shamay S M; Tse, Mimi M Y; Tam, Eric W C; Lai, Cynthia Y Y

    2018-01-10

    (i) To estimate the intra-rater, inter-rater and test-retest reliabilities of the Five-Step Test (FST), as well as the minimum detectable change in FST completion times in people with stroke. (ii) To estimate the convergent validity of the FST with other measures of stroke-specific impairments. (iii) To identify the best cut-off times for distinguishing FST performance in people with stroke from that of healthy older adults. A cross-sectional study. University-based rehabilitation centre. Forty-eight people with stroke and 39 healthy controls. None. The FST, along with (for the stroke survivors only) scores on the Fugl-Meyer Lower Extremity Assessment (FMA-LE), the Berg Balance Scale (BBS), Limits of Stability (LOS) tests, and Activities-specific Balance Confidence (ABC) scale were tested. The FST showed excellent intra-rater (intra-class correlation coefficient; ICC = 0.866-0.905), inter-rater (ICC = 0.998), and test-retest (ICC = 0.838-0.842) reliabilities. A minimum detectable change of 9.16 s was found for the FST in people with stroke. The FST correlated significantly with the FMA-LE, BBS, and LOS results in the forward and sideways directions (r = -0.411 to -0.716, p people with stroke and healthy older adults. The FST is a reliable, easy-to-administer clinical test for assessing stroke survivors' ability to negotiate steps and stairs.

  7. Computer adaptive test performance in children with and without disabilities: prospective field study of the PEDI-CAT

    NARCIS (Netherlands)

    Dumas, H.M.; Fragala-Pinkham, M.A.; Haley, S.M.; Ni, P.; Coster, W.; Kramer, J.M.; Kao, Y.C.; Moed, R.; Ludlow, L.H.

    2012-01-01

    PURPOSE: To examine the discriminant validity, test-retest reliability, administration time and acceptability of the pediatric evaluation of disability inventory computer adaptive test (PEDI-CAT). METHODS: A sample of 102 parents of children 3 through 20 years of age with (n = 50) and without (n =

  8. Validity and reliability of a modified english version of the physical activity questionnaire for adolescents.

    Science.gov (United States)

    Aggio, Daniel; Fairclough, Stuart; Knowles, Zoe; Graves, Lee

    2016-01-01

    Adaptation of physical activity self-report questionnaires is sometimes required to reflect the activity behaviours of diverse populations. The processes used to modify self-report questionnaires though are typically underreported. This two-phased study used a formative approach to investigate the validity and reliability of the Physical Activity Questionnaire for Adolescents (PAQ-A) in English youth. Phase one examined test content and response process validity and subsequently informed a modified version of the PAQ-A. Phase two assessed the validity and reliability of the modified PAQ-A. In phase one, focus groups (n = 5) were conducted with adolescents (n = 20) to investigate test content and response processes of the original PAQ-A. Based on evidence gathered in phase one, a modified version of the questionnaire was administered to participants (n = 169, 14.5 ± 1.7 years) in phase two. Internal consistency and test-retest reliability were assessed using Cronbach's alpha and intra-class correlations, respectively. Spearman correlations were used to assess associations between modified PAQ-A scores and accelerometer-derived physical activity, self-reported fitness and physical activity self-efficacy. Phase one revealed that the original PAQ-A was unrepresentative for English youth and that item comprehension varied. Contextual and population/cultural-specific modifications were made to the PAQ-A for use in the subsequent phase. In phase two, modified PAQ-A scores had acceptable internal consistency (α = 0.72) and test-retest reliability (ICC = 0.78). Modified PAQ-A scores were significantly associated with objectively assessed moderate-to-vigorous physical activity (r = 0.39), total physical activity (r = 0.42), self-reported fitness (r = 0.35), and physical activity self-efficacy (r = 0.32) (p ≤ 0.01). The modified PAQ-A had acceptable internal consistency and test-retest reliability. Modified PAQ-A scores

  9. Harmony in Life Scale - Turkish version: Studies of validity and reliability

    Directory of Open Access Journals (Sweden)

    Seydi Ahmet Satici

    2017-11-01

    Full Text Available Abstract This article presents the adaptation and psychometric evaluation of the Turkish version of Harmony in Life Scale (Turkish-HiL. The present paper investigates (study 1; N 1 = 253 confirmatory factor analysis, measurement invariance; (study 2; N 2 = 231 concurrent validity; (study 3; N 3 = 260 convergent and known-group validities; (study 4; N t − t = 50 test-retest, Cronbach alpha, and composite reliabilities of the Turkish-HiL. In study 1, based on a confirmatory factor analysis, results confirmed that unidimensional-factor structure. The results suggested that the model demonstrated a configural and metric invariance across the gender groups. In study 2, Turkish-HiL significantly correlated with measures of satisfaction with life, subjective happiness, positive affect, and negative affect. In study 3, Turkish-HiL was predicted positively by flourishing, conversely, negatively predicted by depression, anxiety, and stress. Finally, in study 4, alpha, composite and test-retest reliabilities are acceptable. Overall, the scale presented here may prove useful for satisfactorily assessing, in Turkish, the harmony in life of the university students.

  10. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M. H.; Hoozemans, Marco J. M.; Berger, Monique A. M.; van der Slikke, Rienk M. A.; van der Woude, Lucas H. V.; Veeger, Dirkjan (H. E. J)

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  11. Reliability and concurrent validity of a motor skill competence test among 4- to 12-year old children

    NARCIS (Netherlands)

    Hoeboer, Joris; Krijger-Hombergen, Michiel; Savelsbergh, Geert; De Vries, Sanne

    2017-01-01

    The purpose of this study was to examine the test-retest reliability, internal consistency and concurrent validity of the Athletic Skills Track (AST). During a regular PE lesson, 930 4- to 12-year old children (448 girls, 482 boys) completed two motor skill competence tests: (1) the

  12. The Screening Test for Emotional Problems--Teacher-Report Version (Step-T): Studies of Reliability and Validity

    Science.gov (United States)

    Erford, Bradley T.; Butler, Caitlin; Peacock, Elizabeth

    2015-01-01

    The Screening Test for Emotional Problems-Teacher Version (STEP-T) was designed to identify students aged 7-17 years with wide-ranging emotional disturbances. Coefficients alpha and test-retest reliability were adequate for all subscales except Anxiety. The hypothesized five-factor model fit the data very well and external aspects of validity were…

  13. Validity and reliability of the Portuguese-Brazilian version of the Quality of Life in Epilepsy Inventory-89.

    Science.gov (United States)

    Azevedo, Auro Mauro; Alonso, Neide Barreira; Vidal-Dourado, Marcos; Noffs, Maria Helena da Silva; Pascalicchio, Tatiana Frascarelli; Caboclo, Luís Otávio Sales Ferreira; Ciconelli, Rozana Mesquita; Sakamoto, Américo Ceiki; Yacubian, Elza Márcia Targas

    2009-03-01

    The purpose of this article was to report the translation of the Quality of Life in Epilepsy Inventory-89 (QOLIE-89) into a Portuguese-Brazilian version and evaluate its reliability and validity. This study involved 105 outpatients: 54 patients with refractory temporal lobe epilepsy (TLE) with mesial temporal sclerosis (MTS) and 51 with juvenile myoclonic epilepsy (JME). Reliability and test-retest reliability were assessed. Relationships between QOLIE-89 domains and other questionnaires (Nottingham Health Profile, Beck Depression Inventory, Adverse Event Profile, Neuropsychological Evaluation), and external measures such as demographic and clinical variables were analyzed to examine construct validity. Internal consistency (Cronbach's alpha=0.73-0.92) and test-retest reliability (intraclass correlation coefficient=0.60-0.84) for individual domains were acceptable. For construct validity, we verified high correlations between the QOLIE-89 and the Nottingham Health Profile, Beck Depression Inventory, Adverse Event Profile, and Neuropsychological Evaluation. For clinical characteristics, the patients with juvenile myoclonic epilepsy had better quality-of-life scores on 11 of 17 QOLIE-89 subscales compared with patients with temporal lobe epilepsy (P<0.05). These results support the reliability and validity of the Portuguese-Brazilian translation of QOLIE-89.

  14. Intra-session test-retest reliability of magnitude and structure of center of pressure from the Nintendo Wii Balance Board™ for a visually impaired and normally sighted population.

    Science.gov (United States)

    Jeter, Pamela E; Wang, Jiangxia; Gu, Jialiang; Barry, Michael P; Roach, Crystal; Corson, Marilyn; Yang, Lindsay; Dagnelie, Gislin

    2015-02-01

    Individuals with visual impairment (VI) have irreparable damage to one of the input streams contributing to postural stability. Here, we evaluated the intra-session test-retest reliability of the Wii Balance Board (WBB) for measuring Center of Pressure (COP) magnitude and structure, i.e. approximate entropy (ApEn) in fourteen legally blind participants and 21 participants with corrected-to-normal vision. Participants completed a validated balance protocol which included four sensory conditions: double-leg standing on a firm surface with eyes open (EO-firm); a firm surface with eyes closed (EC-firm); a foam surface with EO (EO-foam); and a foam surface with EC (EC-foam). Participants performed the full balance protocol twice during the session, separated by a period of 15min, to determine the intraclass correlation coefficient (ICC). Absolute reliability was determined by the standard error of measurement (SEM). The minimal difference (MD) was estimated to determine clinical significance for future studies. COP measures were derived from data sent by the WBB to a laptop via Bluetooth. COP scores increased with the difficulty of sensory condition indicating WBB sensitivity (all pbalance impairment among VI persons. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. MIDAS and HIT-6 French translation: reliability and correlation between tests.

    Science.gov (United States)

    Magnoux, E; Freeman, M A; Zlotnik, G

    2008-01-01

    The aim was to evaluate the test-retest reliability of the French translation of the Migraine Disability Assessment (MIDAS) and Headache Impact Test (HIT)-6 questionnaires as applied to episodic and chronic headaches and to assess the correlation between these two questionnaires. The MIDAS and HIT-6 questionnaires, which assess the degree of migraine-related functional disability, are widely used in headache treatment clinics. The French translation has not been checked for test-retest reliability. MIDAS involves recall, over the previous 3 months, of the number of days with functional disability with regard to work and to home and social life. HIT-6 involves a more subjective and general assessment of headache-related disability over the previous 4 weeks. We expect that there may be greater impact recall bias for chronic headaches than for episodic headaches and considered it important to be able to determine if the reliability of these questionnaires is equally good for these two patient populations. Given that both questionnaires have the same objective, that of assessing headache impact, it was thought useful to determine if their results might show a correlation and if they could thus be used interchangeably. The study was approved by an external ethics committee. The subjects were patients who regularly visit the Clinique de la Migraine de Montréal, which specializes in the treatment of headaches. The MIDAS and HIT-6 questionnaires were completed by the patients during their regular visit. Twelve days later, the same questionnaires were mailed with a prepaid return envelope. Sixty-five patients were required in both the episodic and chronic headache groups, assuming an 80% questionnaire return rate. One hundred and eighty-five patients were enrolled, and 143 completed the study, 75 with episodic headaches and 68 with chronic headaches. The questionnaire return rate was 78.9%. On average, questionnaires were completed a second time 21 days after the first

  16. The Acceptance of Students with Physical Disabilities by Their Peers in Inclusive and Non-Inclusive Schools in Tehran

    Directory of Open Access Journals (Sweden)

    Narges Adib-Sereshki

    2005-07-01

    Full Text Available Objective: The present research determines the level of peer acceptance of students with physical disabilities in inclusive and non-inclusive schools. A number of studies which have sought to identify the influential factors in the success of inclusive education, have pointed out the acceptance of special need student by his/her regular peers to be a significant variable. Materials & Methods: This is a descriptive investigation. The instrument utilized was the Acceptance Scale (Voelts, 1980. The upper elementary level version that we were used consists of 34 items, two are general friendship items, two are veridicalite items, and the remaining items are acceptance items.Three response options are provided for each item,I agree, I disagree, and maybe. For such reliability, a Spearman-Brown corrected split-half reliability index of +.82 was reported, as well as an alpha coefficient of +.77. A testretest stability coefficient of .68 was obtained by retesting a sample of 101 children on two occasions separated by three weeks. In Iran, with test retest on 72 students we got Reliability coefficient of .83. The sample includes 179 student boys and girls in grades three to five who had classmates with physical disability in their elementary schools in Tehran. This sample was randomly selected from each of the five different regions in the city of Tehran. In addition, for the purpose of comparison, a sample of fifty-five students in similar grades was studied in regular schools. The effect of gender and type of school (inclusive vs. non-inclusive on students’ acceptance of a peer with physical disability all were assessed. Results: Results indicated that acceptance level is similar in boys and in girls in inclusive schools. The girl and boy students in inclusive schools demonstrated a significantly higher level of peer acceptance than their pupils in non-inclusive schools. This difference was much more noticeable in boy students. The lowest level

  17. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review

    OpenAIRE

    Julia Ratter; Lorenz Radlinger; Cees Lucas

    2014-01-01

    Question: Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Design: Systematic review of studies of the psychometric properties of exercise tests. Participants: People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Intervention: Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were ...

  18. Scale for positive aspects of caregiving experience: development, reliability, and factor structure.

    Science.gov (United States)

    Kate, N; Grover, S; Kulhara, P; Nehra, R

    2012-06-01

    OBJECTIVE. To develop an instrument (Scale for Positive Aspects of Caregiving Experience [SPACE]) that evaluates positive caregiving experience and assess its psychometric properties. METHODS. Available scales which assess some aspects of positive caregiving experience were reviewed and a 50-item questionnaire with a 5-point rating was constructed. In all, 203 primary caregivers of patients with severe mental disorders were asked to complete the questionnaire. Internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity were evaluated. Principal component factor analysis was run to assess the factorial validity of the scale. RESULTS. The scale developed as part of the study was found to have good internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity. Principal component factor analysis yielded a 4-factor structure, which also had good test-retest reliability and cross-language reliability. There was a strong correlation between the 4 factors obtained. CONCLUSION. The SPACE developed as part of this study has good psychometric properties.

  19. Reliability and feasibility of the six minute walk test in subjects with myotonic dystrophy.

    Science.gov (United States)

    Kierkegaard, Marie; Tollbäck, Anna

    2007-12-01

    The objective was to describe test-retest reliability and feasibility of the six minute walk test in adult subjects with myotonic dystrophy type 1. Twelve subjects (28-68 years, mean 44) performed three six minute walk tests on two occasions, one week apart. Relative reliability was high (ICC(2.1)=0.99) and absolute reliability values were low (standard error of measurement 12 m, repeatability 33 m). Feasibility was investigated in a sample of 64 subjects (19-70 years, mean 43). Fifty-two subjects were able to perform two tests on the same day. Subjects with severe proximal weakness had difficulties performing repeated tests. A practice trial followed by a second test on the same day can be recommended for most subjects, and the best test should be used for evaluations. In conclusion, even though the study sample was small, the present study indicates that the six minute walk test is reliable and feasible in subjects with myotonic dystrophy type 1.

  20. A reliable and valid questionnaire was developed to measure computer vision syndrome at the workplace.

    Science.gov (United States)

    Seguí, María del Mar; Cabrero-García, Julio; Crespo, Ana; Verdú, José; Ronda, Elena

    2015-06-01

    To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Test-retest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen's kappa (κ). The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good test-retest repeatability both for the scores obtained [ICC = 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (κ = 0.612; 95% CI: 0.384, 0.839). The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. 7 CFR 201.55 - Retests.

    Science.gov (United States)

    2010-01-01

    ... Germination Tests in the Administration of the Act § 201.55 Retests. Retests shall be made as follows: (a) When the range of 100-seed replicates of a given test exceeds the maximum tolerated range in the table... replicates of a given test, rounding off the result to the nearest whole number. The germination is found in...

  2. The reliability of eyetracking to assess attentional bias to threatening words in healthy individuals.

    Science.gov (United States)

    Skinner, Ian W; Hübscher, Markus; Moseley, G Lorimer; Lee, Hopin; Wand, Benedict M; Traeger, Adrian C; Gustin, Sylvia M; McAuley, James H

    2017-08-15

    Eyetracking is commonly used to investigate attentional bias. Although some studies have investigated the internal consistency of eyetracking, data are scarce on the test-retest reliability and agreement of eyetracking to investigate attentional bias. This study reports the test-retest reliability, measurement error, and internal consistency of 12 commonly used outcome measures thought to reflect the different components of attentional bias: overall attention, early attention, and late attention. Healthy participants completed a preferential-looking eyetracking task that involved the presentation of threatening (sensory words, general threat words, and affective words) and nonthreatening words. We used intraclass correlation coefficients (ICCs) to measure test-retest reliability (ICC > .70 indicates adequate reliability). The ICCs(2, 1) ranged from -.31 to .71. Reliability varied according to the outcome measure and threat word category. Sensory words had a lower mean ICC (.08) than either affective words (.32) or general threat words (.29). A longer exposure time was associated with higher test-retest reliability. All of the outcome measures, except second-run dwell time, demonstrated low measurement error ( .93). Recommendations are discussed for improving the reliability of eyetracking tasks in future research.

  3. Reliability and construct validity of Yo-Yo tests in untrained and soccer-trained school-girls aged 9-16

    DEFF Research Database (Denmark)

    Póvoas, Susana C A; Castagna, Carlo; Soares, José Manuel da Costa

    2016-01-01

    Purpose: The reliability and construct validity of three age-adapted-intensity Yo-Yo tests were evaluated in untrained (n=67) vs. soccer-trained (n=65) 9-16-year-old school-girls. Methods: Tests were performed 7 days apart for reliability (9-11-year-old: Yo-Yo intermittent recovery level 1 children...... during test and retest. Conclusion: The Yo-Yo tests are reliable for determining intermittent-exercise capacity and %HRpeak for soccer players and untrained 9-16-year-old girls. They also possess construct validity with better performances for soccer players compared to untrained age-matched girls...

  4. Comparative test-retest reliability of metabolite values assessed with magnetic resonance spectroscopy of the brain. The LCModel versus the manufacturer software.

    Science.gov (United States)

    Fayed, Nicolas; Modrego, Pedro J; Medrano, Jaime

    2009-06-01

    Reproducibility is an essential strength of any diagnostic technique for cross-sectional and longitudinal works. To determine in vivo short-term comparatively, the test-retest reliability of magnetic resonance spectroscopy (MRS) of the brain was compared using the manufacturer's software package and the widely used linear combination of model (LCModel) technique. Single-voxel H-MRS was performed in a series of patients with different pathologies on a 1.5 T clinical scanner. Four areas of the brain were explored with the point resolved spectroscopy technique acquisition mode; the echo time was 35 milliseconds and the repetition time was 2000 milliseconds. We enrolled 15 patients for every area, and the intra-individual variations of metabolites were studied in two consecutive scans without removing the patient from the scanner. Curve fitting and analysis of metabolites were made with the software of GE and the LCModel. Spectra non-fulfilling the minimum criteria of quality in relation to linewidths and signal/noise ratio were rejected. The intraclass correlation coefficients for the N-acetylaspartate/creatine (NAA/Cr) ratios were 0.93, 0.89, 0.9 and 0.8 for the posterior cingulate gyrus, occipital, prefrontal and temporal regions, respectively, with the GE software. For the LCModel, the coefficients were 0.9, 0.89, 0.87 and 0.84, respectively. For the absolute value of NAA, the GE software was also slightly more reproducible than LCModel. However, for the choline/Cr and myo-inositol/Cr ratios, the LCModel was more reliable than the GE software. The variability we have seen hovers around the percentages observed in previous reports (around 10% for the NAA/Cr ratios). We did not find that the LCModel software is superior to the software of the manufacturer. Reproducibility of metabolite values relies more on the observance of the quality parameters than on the software used.

  5. Translation and Adaptation of Knee Injury and Osteoarthritis Outcome Score (KOOS in to Persian and Testing Persian Version Reliability Among Iranians with Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Solaleh Saraei-Pour

    2007-04-01

    Full Text Available Objective: To achieve a reliable tool for measuring health related quality of life among Iranians with knee osteoarthritis, by translating and culturally adapting the Knee injury and Osteoarthritis Outcome Score(KOOS to Persian and testing the reliability and internal consistency of the Iranian version. Materials & Methods: It was a non experimental methodology study. KOOS was translated and adapted culturally to Persian language and culture in three phases with respect to IQOLA project. For examining test-retest reliability Iranians version of KOOS was corresponded twice with in at least two days or at most one week interval, by 30 Iranian people with knee OA whom were referred to Municipality and 110 physiotherapy clinics of Tehran with PT order by physicians. It was a non experimental methodological research and we used sample of convenience and non probability design for sampling. Psychometric evaluation: the collected data from the questionnaires was rated and analyzed with SPSS software from the aspects of test-retest reliability, absolute reliability, subscale and item internal consistency. Results: Internal consistency which was calculated by Cronbach '&alpha was high for all the subscales (at least 0.76, except for "symptom" subscale which was moderate, and showed that items of each subscale measured the same construct. Item internal consistency after correction for overlap, was higher than optimal value (0.4, except for the items of" symptom" subscale , which demonstrated good item internal consistency. SEM and ICC which were used for evaluating the absolute and test-retest reliability in respect showed that all the subscales had good test-retest reliability (0.7 and the absolute reliability was also very good in such away that the highest calculated SEM for Persian version was 7.44 which was less than Minimal Perceptible Clinical Improvement (MPCI that is estimated 8 to 10 for the KOOS questionnaire. Conclusion: With the Persian

  6. Reliability and minimal detectable change of a modified passive neck flexion test in patients with chronic nonspecific neck pain and asymptomatic subjects.

    Science.gov (United States)

    López-de-Uralde-Villanueva, Ibai; Acuyo-Osorio, Mario; Prieto-Aldana, María; La Touche, Roy

    2017-04-01

    The Passive Neck Flexion Test (PNFT) can diagnose meningitis and potential spinal disorders. Little evidence is available concerning the use of a modified version of the PNFT (mPNFT) in patients with chronic nonspecific neck pain (CNSNP). To assess the reliability of the mPNFT in subjects with and without CNSNP. The secondary objective was to assess the differences in the symptoms provoked by the mPNFT between these two populations. We used repeated measures concordance design for the main objective and cross-sectional design for the secondary objective. A total of 30 asymptomatic subjects and 34 patients with CNSNP were recruited. The following measures were recorded: the range of motion at the onset of symptoms (OS-mPNFT), the range of motion at the submaximal pain (SP-mPNFT), and evoked pain intensity on the mPNFT (VAS-mPNFT). Good to excellent reliability was observed for OS-mPNFT and SP-mPNFT in the asymptomatic group (intra-examiner reliability: 0.95-0.97; inter-examiner reliability: 0.86-0.90; intra-examiner test-retest reliability: 0.84-0.87). In the CNSNP group, a good to excellent reliability was obtained for the OS-mPNFT (intra-examiner reliability: 0.89-0.96; inter-examiner reliability: 0.83-0.86; intra-examiner test-retest reliability: 0.83-0.85) and the SP-PNFT (intra-examiner reliability: 0.94-0.98; inter-examiner reliability: 0.80-0.82; intra-examiner test-retest reliability: 0.88-0.91). The CNSNP group showed statistically significant differences in OS-mPNFT (t = 4.92; P reliable tool regardless of the examiner and the time factor. Patients with CNSNP have a decrease range of motion and more pain than asymptomatic subjects in the mPNFT. This exceeds the minimal detectable changes for OS-mPNFT and VAS-mPNFT. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. The reliability and validity of a sexual functioning questionnaire.

    Science.gov (United States)

    Corty, E W; Althof, S E; Kurit, D M

    1996-01-01

    The present study assessed the reliability and validity of a measure of sexual functioning, the CMSH-SFQ, for male patients and their partners. The CMSH-SFQ measures erectile and orgasmic functioning, sexual drive, frequency of sexual behavior, and sexual satisfaction. Test-retest reliability was assessed with 19 males and 19 females for the baseline CMSH-SFQ. Criterion validity was measured by comparing the answers of 25 male patients to those of their partners at baseline and follow-up. The majority of items had acceptable levels of reliability and validity. The CMSH-SFQ provides a reliable and valid device that can be used to measure global sexual functioning in men and their partners and may be used to evaluate the efficacy of treatments for sexual dysfunctions. Limitations and suggestions for use of the CMSH-SFQ are addressed.

  8. A Computer-Based Sustained Visual Attention Test for Pre-School Children: Design, Development and Psychometric Properties

    Directory of Open Access Journals (Sweden)

    Roohollah Zahedian Nasb

    2016-06-01

    Full Text Available Background: Sustained visual attention is a prerequisite for learning and memory. The early evaluation of attention in childhood is essential for their school and career success in the future. The aim of this study was to design, development and investigation of psychometric properties (content, face and convergent validity and test-retest and internal consistency reliability of the computer - based sustained visual attention test (SuVAT for healthy preschool children aged 4-6 with their special needs. Methods: This study was carried out in two stages: in the first stage computerbased SuVAT in two versions original and parallel were developed. Then the test-retest and internal consistency reliability using intra-class correlation and Cronbach’s alpha coefficients respectively were examined; Face validity was calculated through ideas gathering from 10 preschool children and content validity evaluated using CVI and CVR method and convergent validity of SuVAT with CPT was assessed using Pearson correlation. Results: The developed test showed a good content and faces validity, and also had excellent test-retest reliability. In addition, the assessment of internal consistency indicated the high internal consistency of the test (Cronbach’s alpha=0.869. SuVAT and CPT test demonstrated a positive correlation upon the convergent validity testing. Conclusion: SuVAT with good reliability and validity could be used as an acceptable sustained attention assessment in preschool children.

  9. Validity and Reliability of Curl-Up Test on Assessing the Core Endurance for Kindergarten Children in Hong Kong

    OpenAIRE

    Lai, CY; Lee, KY; Lams, MHS; Wu, CF; Peake, R; Flint, SW; Li, WHC; Ho, E

    2017-01-01

    Objective: The purpose of this study was to examine the test-retest reliability and the criterion validity of a curlup\\ud test (CUT) as a measure of core stability, core endurance and dynamic stability in kindergarten children. CUT\\ud performance was also compared to half hold lying test (HHLT) and walking time on course (WTC) among without\\ud obstacle, with low obstacle and high obstacle measures of core stability, core endurance and dynamic stability.\\ud Methods: To estimate reliability, 33...

  10. Test-retest paradigm of the forced swimming test in female mice is not valid for predicting antidepressant-like activity: participation of acetylcholine and sigma-1 receptors.

    Science.gov (United States)

    Su, Jing; Hato-Yamada, Noriko; Araki, Hiroaki; Yoshimura, Hiroyuki

    2013-01-01

    The forced swimming test (FST) in mice is widely used to predict the antidepressant activity of a drug, but information describing the immobility of female mice is limited. We investigated whether a prior swimming experience affects the immobility duration in a second FST in female mice and whether the test-retest paradigm is a valid screening tool for antidepressants. Female ICR mice were exposed to the FST using two experimental paradigms: a single FST and a double FST in which mice had experienced FST once 24 h prior to the second trail. The initial FST experience reliably prolonged immobility duration in the second FST. The antidepressants imipramine and paroxetine significantly reduced immobility duration in the single FST, but not in the double FST. Scopolamine and the sigma-1 (σ1) antagonist NE-100 administered before the second trial significantly prevented the prolongation of immobility. Neither a 5-HT1A nor a 5-HT2A receptor agonist affected immobility duration. We suggest that the test-retest paradigm in female mice is not adequate for predicting antidepressant-like activity of a drug; the prolongation of immobility in the double FST is modulated through acetylcholine and σ1 receptors.

  11. Development of a Saudi Food Frequency Questionnaire and testing its reliability and validity

    OpenAIRE

    Gosadi, Ibrahim M.; Alatar, Abdullah A.; Otayf, Mojahed M.; AlJahani, Dhaherah M.; Ghabbani, Hisham M.; AlRajban, Waleed A.; Alrsheed, Abdullah M.; Al-Nasser, Khalid A.

    2017-01-01

    Objectives: To create a food frequency questionnaire specifically designed to capture the dietary habits of Saudis and test its validity and reliability. Methods: This investigation is a longitudinal, test-retest study conducted in King Saud University, Riyadh, Kingdom of Saudi Arabia between December 2015 and March 2016. A list of 140 food items was included in the questionnaire where a closed-ended and open-ended approach was used. Regarding past year food frequency consumption and 24 hours...

  12. Comprehension of Written Grammar Test: Reliability and Known-Groups Validity Study With Hearing and Deaf and Hard-of-Hearing Students.

    Science.gov (United States)

    Cannon, Joanna E; Hubley, Anita M; Millhoff, Courtney; Mazlouman, Shahla

    2016-01-01

    The aim of the current study was to gather validation evidence for the Comprehension of Written Grammar (CWG; Easterbrooks, 2010) receptive test of 26 grammatical structures of English print for use with children who are deaf and hard of hearing (DHH). Reliability and validity data were collected for 98 participants (49 DHH and 49 hearing) in Grades 2-6. The objectives were to: (a) examine 4-week test-retest reliability data; and (b) provide evidence of known-groups validity by examining expected differences between the groups on the CWG vocabulary pretest and main test, as well as selected structures. Results indicated excellent test-retest reliability estimates for CWG test scores. DHH participants performed statistically significantly lower on the CWG vocabulary pretest and main test than the hearing participants. Significantly lower performance by DHH participants on most expected grammatical structures (e.g., basic sentence patterns, auxiliary "be" singular/plural forms, tense, comparatives, and complementation) also provided known groups evidence. Overall, the findings of this study showed strong evidence of the reliability of scores and known group-based validity of inferences made from the CWG. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Reliability of a questionnaire on substance use among adolescent students, Brazil.

    Science.gov (United States)

    Machado Neto, Adelmo de Souza; Andrade, Tarcisio Matos; Fernandes, Gilênio Borges; Zacharias, Helder Paulo; Carvalho, Fernando Martins; Machado, Ana Paula Souza; Dias, Ana Carmen Costa; Garcia, Ana Carolina Rocha; Santana, Lauro Reis; Rolin, Carlos Eduardo; Sampaio, Cyntia; Ghiraldi, Gisele; Bastos, Francisco Inácio

    2010-10-01

    To analyze reliability of a self-applied questionnaire on substance use and misuse among adolescent students. Two cross-sectional studies were carried out for the instrument test-retest. The sample comprised male and female students aged 1119 years from public and private schools (elementary, middle, and high school students) in the city of Salvador, Northeastern Brazil, in 2006. A total of 591 questionnaires were applied in the test and 467 in the retest. Descriptive statistics, the Kappa index, Cronbach's alpha and intraclass correlation were estimated. The prevalence of substance use/misuse was similar in both test and retest. Sociodemographic variables showed a "moderate" to "almost perfect" agreement for the Kappa index, and a "satisfactory" (>0.75) consistency for Cronbach's alpha and intraclass correlation. The age which psychoactive substances (tobacco, alcohol, and cannabis) were first used and chronological age were similar in both studies. Test-retest reliability was found to be a good indicator of students' age of initiation and their patterns of substance use. The questionnaire reliability was found to be satisfactory in the population studied.

  14. Feasibility and test-retest reliability of measuring lower-limb strength in young children with cerebral palsy

    NARCIS (Netherlands)

    Van Vulpen, L. F.; de Groot, Sonja; Becher, J. G.; De Wolf, G. S.; Dallmeijer, A. J.

    2013-01-01

    BACKGROUND: Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. AIM: To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions)

  15. Feasibility and test-retest reliability of measuring lower‑limb strength in young children with cerebral palsy

    NARCIS (Netherlands)

    van Vulpen, L. F.; de Groot, S.; Becher, J. G.; de Wolf, G. S.; Dallmeijer, A. J.

    2013-01-01

    Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions) of measuring

  16. Technical note: Intraobserver, interobserver, and test-retest reliabilities of an assessment of vaginal discharge from cows with and without acute puerperal metritis.

    Science.gov (United States)

    Sannmann, I; Heuwieser, W

    2015-08-01

    Acute puerperal metritis (APM) in dairy cows is a common disease occurring in the first 10 d after calving. According to a widely accepted definition, the diagnosis is primarily based on body temperature and sensorial assessment of vaginal discharge. The scope of this study was to evaluate the reliability for color, smell, and viscosity of vaginal discharge from healthy cows and cows with APM. Fifteen investigators evaluated 6 vaginal discharge samples 10 times. Subsequently, the investigators rated the health status of the cows and the diagnostic value of color, smell, and viscosity. In a final questionnaire, the investigators estimated their ability to diagnose APM correctly and the influence of experience. Reliability was tested using Cohen's kappa (κ). Our study revealed slight to moderate reliabilities concerning the assessment of vaginal discharge. Overall interobserver reliability for color, smell, and viscosity was κ=0.15, 0.27, and 0.44, respectively. Overall intraobserver reliability for color, smell, and viscosity was κ=0.35, 0.39, and 0.6, respectively. By means of a questionnaire, overall personal expertise to detect cows suffering from APM correctly as such was estimated to be 59%, whereas the diagnostic value of a combination of color, smell, and viscosity to detect cows with APM correctly was estimated to be 91.1% perfect. We found a discrepancy between reliability and the personal perception of diagnostic value. Our study shows that the sensorial assessment of color, smell, and viscosity of vaginal discharge in cows postpartum is subjective. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Reliability and normative data for the comprehensive assessment of prospective memory (CAPM).

    Science.gov (United States)

    Chau, Lien T; Lee, Jessica B; Fleming, Jennifer; Roche, Nadine; Shum, David

    2007-12-01

    The Comprehensive Assessment of Prospective Memory (CAPM) is a questionnaire designed to evaluate frequency of prospective memory (PM) failures in people with brain injury. The aims of this study were to investigate the psychometric properties of the CAPM, including test-retest reliability and internal consistency, and to establish normative data by comparing CAPM scores between groups on the basis of sex, age, and education. Data were collected on 95 people aged 15-60 years living in the community, with no history of brain injury, using the CAPM. The results showed that the test-retest reliability and internal consistency for the CAPM were within acceptable ranges, indicating that the CAPM provides a stable and homogenous measure of an individual's self-report of PM failures. Normative data are presented in two age groups based on the significant difference found between the age groups 15-30 years and 31-60 years. These established norms can be used to describe perceived or observed behaviours indicative of PM failure in patients with brain injury by comparing CAPM ratings from significant others with the norms. The CAPM questionnaire provides researchers or clinicians with a stable and reliable assessment option that specifically focuses on PM for individuals with brain injury.

  18. Validity and reliability of a Nigerian-Yoruba version of the stroke-specific quality of life scale 2.0.

    Science.gov (United States)

    Odetunde, Marufat Oluyemisi; Akinpelu, Aderonke Omobonike; Odole, Adesola Christiana

    2017-10-19

    Psychometric evidence is necessary to establish scientific integrity and clinical usefulness of translations and cultural adaptations of the Stroke-Specific Quality of Life (SS-QoL) scale. However, the limited evidence on psychometrics of Yoruba version of SS-QoL 2.0 (SS-QoL(Y)) is a significant shortcoming. This study assessed the test-retest reliability, internal consistency, convergent, divergent, discriminant and known-group validity of the SS-QoL(Y). Yoruba version of the WHOQoL-BREF was used to test the convergent and divergent validity of the SS-QoL(Y) among 100 consenting stroke survivors. The WHOQoL-BREF and SS-QoL(Y) was administered randomly in order to eliminate bias. The test-retest reliability of the SS-QoL(Y) was carried out among 68 of the respondents within an interval of 7 days. All respondents were purposively recruited from selected secondary and tertiary health facilities in South-west Nigeria. Data were analysed using descriptive statistics of mean and standard deviation, and inferential statistics of Spearman correlation, Cronbach's alpha, Intra-class Correlation Coefficient (ICC), Independent t-test and One-way ANOVA. Alpha level was set at p validity of SS-QoL(Y) showed that items' r value ranged from 0.711 to 0.920 with their hypothesized domains. The scale demonstrated moderate to strong test-retest reliability with Intra-class correlation coefficient (ICC) for the domains and overall scores (r = 0.47 to 0.81) and moderate to high internal consistency (Cronbach's alpha =0.61 to 0.82) for domains scores. These correlations were also significant for the domains and overall scores (p validity, test-retest reliability and internal consistency of the Yoruba version of the Stroke Specific Quality of Life 2.0 are adequate while the convergent and divergent validity are low but acceptable. The SS-QoL(Y) is recommended for assessing health-related quality of life among Yoruba stroke survivors.

  19. Learning effect and test-retest variability of pulsar perimetry.

    Science.gov (United States)

    Salvetat, Maria Letizia; Zeppieri, Marco; Parisi, Lucia; Johnson, Chris A; Sampaolesi, Roberto; Brusini, Paolo

    2013-03-01

    To assess Pulsar Perimetry learning effect and test-retest variability (TRV) in normal (NORM), ocular hypertension (OHT), glaucomatous optic neuropathy (GON), and primary open-angle glaucoma (POAG) eyes. This multicenter prospective study included 43 NORM, 38 OHT, 33 GON, and 36 POAG patients. All patients underwent standard automated perimetry and Pulsar Contrast Perimetry using white stimuli modulated in phase and counterphase at 30 Hz (CP-T30W test). The learning effect and TRV for Pulsar Perimetry were assessed for 3 consecutive visual fields (VFs). The learning effect were evaluated by comparing results from the first session with the other 2. TRV was assessed by calculating the mean of the differences (in absolute value) between retests for each combination of single tests. TRV was calculated for Mean Sensitivity, Mean Defect, and single Mean Sensitivity for each 66 test locations. Influence of age, VF eccentricity, and loss severity on TRV were assessed using linear regression analysis and analysis of variance. The learning effect was not significant in any group (analysis of variance, P>0.05). TRV for Mean Sensitivity and Mean Defect was significantly lower in NORM and OHT (0.6 ± 0.5 spatial resolution contrast units) than in GON and POAG (0.9 ± 0.5 and 1.0 ± 0.8 spatial resolution contrast units, respectively) (Kruskal-Wallis test, P=0.04); however, the differences in NORM among age groups was not significant (Kruskal-Wallis test, P>0.05). Slight significant differences were found for the single Mean Sensitivity TRV among single locations (Duncan test, PPulsar Perimetry CP-T30W test did not show significant learning effect in patients with standard automated perimetry experience. TRV for global indices was generally low, and was not related to patient age; it was only slightly affected by VF defect eccentricity, and significantly influenced by VF loss severity.

  20. A Turkish version of myocardial infarction dimensional assessment scale (TR-MIDAS): reliability-validity assesment.

    Science.gov (United States)

    Uysal, Hilal; Ozcan, Şeyda

    2011-06-01

    Many new measuring devices have been developed so that broader psychometric measurements in the coronary artery disease, disease-specific health status measurements, and identification of the broader quality of life can be performed in the recent years. The study was intended to determine whether, and to what extent, MIDAS is a valid and reliable measurement to the patients suffering from myocardial infarction for the first time in Turkey. The research was conducted with the patients hospitalized and treated with myocardial infarction in the cardiology departments of 2 hospitals in Istanbul, Turkey, between 2007 and 2008. Psychometric evaluations of TR-MIDAS were used for validity studies; language validity, content validity, construct validity were examined. For reliability studies; the tool's internal consistency reliability, Cronbach's alpha reliability coefficient, and test-retest reliability were completed. The instrument's content validity index was determined to be "0.95". Principal component analysis revealed six factors with an eigenvalue >1.5. Cronbach's alpha was found to be 0.89 for total scale which was an acceptable value. The total's test-retest reliability was 0.51 (p<0.01). Data obtained at the end of the study supports that Turkish Myocardial Infarction Dimensional Assessment Scale is a valid and reliable instrument as a disease-specific scale to assess the patients' quality of life suffering from myocardial infarction in Turkey. Copyright © 2010 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  1. Test-Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease.

    Science.gov (United States)

    Palkovits, Stefan; Hirnschall, Nino; Georgiev, Stefan; Leisser, Christoph; Findl, Oliver

    2018-02-01

    To evaluate the test-retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test-retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] -1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR -1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. The microperimeter MP3 shows an adequate test-retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies.

  2. Intersession reliability of self-selected and narrow stance balance testing in older adults.

    Science.gov (United States)

    Riemann, Bryan L; Piersol, Kelsey

    2017-10-01

    Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.

  3. Test-retest reliability of joint position and kinesthetic sense in the elbow of healthy subjects

    DEFF Research Database (Denmark)

    Juul-Kristensen, B.; Lund, Hans Aage; Hansen, K.

    2008-01-01

    Proprioception is an important effect measure in neuromuscular function training in physiotherapy. Reliability studies of methods for measuring proprioception are few on joint position sense (JPS) and threshold to detection of a passive movement (TDPM) on the elbow. The aim was to study test-rete...

  4. Short message service reminder intervention doubles sexually transmitted infection/HIV re-testing rates among men who have sex with men.

    Science.gov (United States)

    Bourne, C; Knight, V; Guy, R; Wand, H; Lu, H; McNulty, A

    2011-04-01

    To evaluate the impact of a short message service (SMS) reminder system on HIV/sexually transmitted infection (STI) re-testing rates among men who have sex with men (MSM). The SMS reminder programme started in late 2008 at a large Australian sexual health clinic. SMS reminders were recommended 3-6 monthly for MSM considered high-risk based on self-reported sexual behaviour. The evaluation compared HIV negative MSM who had a HIV/STI test between 1 January and 31 August 2010 and received a SMS reminder (SMS group) with those tested in the same time period (comparison group) and pre-SMS period (pre-SMS group, 1 January 2008 and 31 August 2008) who did not receive the SMS. HIV/STI re-testing rates were measured within 9 months for each group. Baseline characteristics were compared between study groups and multivariate logistic regression used to assess the association between SMS and re-testing and control for any imbalances in the study groups. There were 714 HIV negative MSM in the SMS group, 1084 in the comparison group and 1753 in the pre-SMS group. In the SMS group, 64% were re-tested within 9 months compared to 30% in the comparison group (preminders increased HIV/STI re-testing among HIV negative MSM. SMS offers a cheap, efficient system to increase HIV/STI re-testing in a busy clinical setting.

  5. Reliability of the Client-Centeredness of Goal Setting (C-COGS) Scale in Acquired Brain Injury Rehabilitation.

    Science.gov (United States)

    Doig, Emmah; Prescott, Sarah; Fleming, Jennifer; Cornwell, Petrea; Kuipers, Pim

    2016-01-01

    To examine the internal reliability and test-retest reliability of the Client-Centeredness of Goal Setting (C-COGS) scale. The C-COGS scale was administered to 42 participants with acquired brain injury after completion of multidisciplinary goal planning. Internal reliability of scale items was examined using item-partial total correlations and Cronbach's α coefficient. The scale was readministered within a 1-mo period to a subsample of 12 participants to examine test-retest reliability by calculating exact and close percentage agreement for each item. After examination of item-partial total correlations, test items were revised. The revised items demonstrated stronger internal consistency than the original items. Preliminary evaluation of test-retest reliability was fair, with an average exact percent agreement across all test items of 67%. Findings support the preliminary reliability of the C-COGS scale as a tool to evaluate and promote client-centered goal planning in brain injury rehabilitation. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  6. Validity and reliability of the single-trial line drill test of anaerobic power in basketball players.

    Science.gov (United States)

    Fatouros, I G; Laparidis, K; Kambas, A; Chatzinikolaou, A; Techlikidou, E; Katrabasas, I; Douroudos, I; Leontsini, D; Berberidou, F; Draganidis, D; Christoforidis, C; Tsoukas, D; Kelis, S; Taxildaris, K

    2011-03-01

    This study evaluated the validity, reliability, and sensitivity of the single-trial line drill test (SLDT) for anaerobic power assessment. Twenty-four volunteers were assigned to either a control (C, N.=12) or an experimental (BP, N.=12 basketball players) group. SLDT's (time-to-complete) concurrent validity was evaluated against the Wingate testing (WAnT: mean [MP] and peak power [PP]) and a 30-sec vertical jump testing test (VJT: mean height and MP). Blood lactate concentration was measured at rest and immediately post-test. SLDT's reliability [test-retest intraclass correlation coefficients (ICC), coefficient of variation (CV), Bland-Altman plots] and sensitivity were determined (one-way ANOVA). Kendall's tau correlation analysis revealed correlations (Pbasketball players.

  7. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  8. A Review and Comparison of the Reliabilities of the MMPI-2, MCMI-III, and PAI Presented in Their Respective Test Manuals

    Science.gov (United States)

    Wise, Edward A.; Streiner, David L.; Walfish, Steven

    2010-01-01

    This article provides a review of the literature to determine the most frequently used personality tests. Based on this review, internal consistency and test-retest reliability coefficients from the test manuals for the Minnesota Multiphasic Personality Inventory-2 (MMPI-2), Millon Clinical Multiaxial Inventory-III (MCMI-III), and Personality…

  9. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  10. The "Reading the Mind in the Eyes" Test: Investigation of Psychometric Properties and Test-Retest Reliability of the Persian Version

    Science.gov (United States)

    Khorashad, Behzad S.; Baron-Cohen, Simon; Roshan, Ghasem M.; Kazemian, Mojtaba; Khazai, Ladan; Aghili, Zahra; Talaei, Ali; Afkhamizadeh, Mozhgan

    2015-01-01

    The psychometric properties of the Persian "Reading the Mind in the Eyes" test were investigated, so were the predictions from the Empathizing-Systemizing theory of psychological sex differences. Adults aged 16-69 years old (N = 545, female = 51.7%) completed the test online. The analysis of items showed them to be generally acceptable.…

  11. [11C]Harmine Binding to Brain Monoamine Oxidase A: Test-Retest Properties and Noninvasive Quantification.

    Science.gov (United States)

    Zanderigo, Francesca; D'Agostino, Alexandra E; Joshi, Nandita; Schain, Martin; Kumar, Dileep; Parsey, Ramin V; DeLorenzo, Christine; Mann, J John

    2018-02-08

    Inhibition of the isoform A of monoamine oxidase (MAO-A), a mitochondrial enzyme catalyzing deamination of monoamine neurotransmitters, is useful in treatment of depression and anxiety disorders. [ 11 C]harmine, a MAO-A PET radioligand, has been used to study mood disorders and antidepressant treatment. However, [ 11 C]harmine binding test-retest characteristics have to date only been partially investigated. Furthermore, since MAO-A is ubiquitously expressed, no reference region is available, thus requiring arterial blood sampling during PET scanning. Here, we investigate [ 11 C]harmine binding measurements test-retest properties; assess effects of using a minimally invasive input function estimation on binding quantification and repeatability; and explore binding potentials estimation using a reference region-free approach. Quantification of [ 11 C]harmine distribution volume (V T ) via kinetic models and graphical analyses was compared based on absolute test-retest percent difference (TRPD), intraclass correlation coefficient (ICC), and identifiability. The optimal procedure was also used with a simultaneously estimated input function in place of the measured curve. Lastly, an approach for binding potentials quantification in absence of a reference region was evaluated. [ 11 C]harmine V T estimates quantified using arterial blood and kinetic modeling showed average absolute TRPD values of 7.7 to 15.6 %, and ICC values between 0.56 and 0.86, across brain regions. Using simultaneous estimation (SIME) of input function resulted in V T estimates close to those obtained using arterial input function (r = 0.951, slope = 1.073, intercept = - 1.037), with numerically but not statistically higher test-retest difference (range 16.6 to 22.0 %), but with overall poor ICC values, between 0.30 and 0.57. Prospective studies using [ 11 C]harmine are possible given its test-retest repeatability when binding is quantified using arterial blood. Results with SIME of

  12. Reliability of short form-36 in an Internet- and a pen-and-paper version

    DEFF Research Database (Denmark)

    Basnov, Maja; Kongsved, Sissel Marie; Bech, Per

    2009-01-01

    Use of Internet versions of questionnaires may have several advantages in clinical and epidemiological research, but we know little about if Internet versions differ with respect to validity and reliability. We aimed to compare Internet- and pen-and-paper versions of short form-36 (SF-36......) with respect to test-retest reliability and internal consistency. Women referred to mammography (n = 782) were randomised to receive either a paper version with a prepaid return envelope or a guideline on how to fill in the Internet version. A subgroup was asked to answer the questionnaire once again...... in the alternative version. Test-retest reliability was assessed by the intra-class correlation coefficient. Internal consistency was calculated as Cronbach's alpha. The between-version test-retest reliability for the eight subscales were between 0.63 and 0.92. Cronbach's alpha for the two versions were all between...

  13. Chinese version of the Constant-Murley questionnaire for shoulder pain and disability: a reliability and validation study.

    Science.gov (United States)

    Yao, Min; Yang, Long; Cao, Zuo-Yuan; Cheng, Shao-Dan; Tian, Shuang-Lin; Sun, Yue-Li; Wang, Jing; Xu, Bao-Ping; Hu, Xiao-Chun; Wang, Yong-Jun; Zhang, Ying; Cui, Xue-Jun

    2017-09-18

    Shoulder pain is a common musculoskeletal disorder in Chinese population, which affects more than 1,3 billion individuals. To the best of our knowledge, there has been no available Chinese-language version of measurements of shoulder pain and disability so far. Moreover, the Constant-Murley score (CMS) questionnaire is a universally recognized patient-reported questionnaire for clinical practice and research. The present study was designed to evaluate a Chinese translational version of CMS and subsequently assess its reliability and validity. The Chinese translational version of CMS was formulated by means of forward-backward translation. Meanwhile, a final review was carried out by an expert committee, followed by conducting a test of the pre-final version. Therefore, the reliability and validity of the Chinese translational version of CMS could be assessed using the internal consistency, construct validity, factor analysis, reliability and floor and ceiling effects. Specifically, the reliability was assessed by testing the internal consistency (Cronbach's α) and test-retest reliability (intraclass coefficient correlation [ICC]), while the construct validity was evaluated via comparison between the Chinese translational version of CMS with visual analog scale (VAS) score and the 36-Item Short Form Health Survey (SF-36, Spearman correlation). The questionnaire was verified to be acceptable after distribution among 120 subjects with unilateral shoulder pain. Factor analysis had revealed a two-factor and 10-item solution. Moreover, the assessment results indicated that the Chinese translational version of CMS questionnaire harbored good internal consistency (Cronbach's α = 0.739) and test-retest reliability (ICC = 0.827). In addition, the Chinese translational version of CMS was moderately correlated with VAS score (r = 0.497) and SF-36 (r = 0.135). No obvious floor and ceiling effects were observed in the Chinese translational version of CMS questionnaire

  14. Reliability, Validity, and Sensitivity of a Novel Smartphone-Based Eccentric Hamstring Strength Test in Professional Football Players.

    Science.gov (United States)

    Lee, Justin W Y; Cai, Ming-Jing; Yung, Patrick S H; Chan, Kai-Ming

    2018-05-01

    To evaluate the test-retest reliability, sensitivity, and concurrent validity of a smartphone-based method for assessing eccentric hamstring strength among male professional football players. A total of 25 healthy male professional football players performed the Chinese University of Hong Kong (CUHK) Nordic break-point test, hamstring fatigue protocol, and isokinetic hamstring strength test. The CUHK Nordic break-point test is based on a Nordic hamstring exercise. The Nordic break-point angle was defined as the maximum point where the participant could no longer support the weight of his body against gravity. The criterion for the sensitivity test was the presprinting and postsprinting difference of the Nordic break-point angle with a hamstring fatigue protocol. The hamstring fatigue protocol consists of 12 repetitions of the 30-m sprint with 30-s recoveries between sprints. Hamstring peak torque of the isokinetic hamstring strength test was used as the criterion for validity. A high test-retest reliability (intraclass correlation coefficient = .94; 95% confidence interval, .82-.98) was found in the Nordic break-point angle measurements. The Nordic break-point angle significantly correlated with isokinetic hamstring peak torques at eccentric action of 30°/s (r = .88, r 2  = .77, P hamstring strength measures among male professional football players.

  15. The reliability and validity of the Danish Draft Board Cognitive Ability Test: Børge Prien's Prøve.

    Science.gov (United States)

    Teasdale, Thomas W; Hartmann, Peter V W; Pedersen, Christoffer H; Bertelsen, Mette

    2011-04-01

    The Danish Draft Board has used the same test for assessing general cognitive ability, the Børge Prien's Prøve (BPP), for over 50 years during which time all men on reaching the age of 18 become liable for conscription. Data from the test has, over the decades, been used in numerous and wide-ranging research studies. Nonetheless, owing to the special circumstances of its administration, some psychometric properties, which are generally assessed for psychological tests, have not previously been investigated for the BPP. First, since the test is only used at the assessment phase, retesting with the BPP occurs only rarely and under exceptional circumstances. Therefore, its Test-Retest reliability has hitherto not been documented. Second, questions have often been raised as to whether the validity of the BPP is undermined by either a lack of motivation and under-performing among some of the men taking the test, being, as they are, compelled to do so, and/or by gradual obsolescence of the test over the decades of its use. We here present findings from three new studies to show that (a) the BPP has a satisfactory Test-Retest reliability, r=0.77, (b) BPP test scores are not positively associated with expressed attitude to being called upon to serve conscription and (c) the correlation between the BPP and a measure of educational level has remained stable (at about 0.5) through the last two decades. Taken together these three findings further support the continuing value of the BPP in research relating to cognitive ability. © 2010 The Authors. Scandinavian Journal of Psychology © 2010 The Scandinavian Psychological Associations.

  16. Test-retest reliability of [{sup 11}C]AZ10419369 binding to 5-HT{sub 1B} receptors in human brain

    Energy Technology Data Exchange (ETDEWEB)

    Nord, Magdalena; Finnema, Sjoerd J.; Schain, Martin; Halldin, Christer; Farde, Lars [Karolinska Institutet, Center for Psychiatric Research, R5:00, Karolinska University Hospital, Department of Clinical Neuroscience, Stockholm (Sweden)

    2014-02-15

    [{sup 11}C]AZ10419369 is a recently developed 5-HT{sub 1B} receptor radioligand that is sensitive to changes in endogenous serotonin concentrations in the primate brain. Thus, [{sup 11}C] AZ10419369 may serve as a useful tool in clinical studies of the pathophysiology and pharmacological treatment of diseases related to the serotonin system, such as depression and anxiety disorders. The aim of this study was to evaluate the test-retest reliability of [{sup 11}C]AZ10419369. Eight men were examined with PET and [{sup 11}C] AZ10419369 twice on the same day. The binding potentials (BP{sub ND}) of [{sup 11}C]AZ10419369 in selected serotonergic projection areas and in the raphe nuclei (RN) were determined using the simplified reference tissue model, and for comparison also using a wavelet-aided parametric imaging approach. The BP{sub ND} values obtained from the first and second PET scans were compared by means of descriptive statistics, difference, absolute variability and intraclass correlation coefficient. Similar BP{sub ND} values were obtained with the two methods. The absolute mean differences in BP{sub ND} between PET 1 and PET 2 were less than 3 % in all serotonergic projection regions. Absolute variabilities were low in cortical regions (5 - 7 %), low to moderate (7 - 14 %) in subcortical regions, but higher (20 %) in the RN. The BP{sub ND} of [{sup 11}C]AZ10419369 is highly reproducible in cortical regions and satisfactory in subcortical projection areas. The variability in the RN is higher. Thus larger sample sizes or larger divergences are required to assess a potential difference between subjects or between experimental conditions in this region. (orig.)

  17. Dual conception of risk in the Iowa Gambling Task: Effects of sleep deprivation and test-retest gap

    Directory of Open Access Journals (Sweden)

    Varsha eSingh

    2013-09-01

    Full Text Available Risk in the Iowa Gambling Task (IGT is often understood in terms of intertemporal choices, i.e., preference for immediate outcomes in favor of delayed outcomes is considered risky. According to behavioral economics, decision makers refrain from choosing the short-sighted immediate gain because, over time (10 trials, the immediate gains result in a net loss. Instead decision makers are expected to maximize their gains by choosing options that, over time (10 trials, result in net gain. However, task choices are sometimes made on the basis of the frequency of reward and punishment such that infrequent punishments are favored over frequent punishments. The presence of these two attributes (intertemporality and frequency may correspond to the emotion-cognition dichotomy and reflect a dual conception of risk. Decision making on the basis of the two attributes was tested under two conditions: test-retest gap and sleep deprivation. An interaction between these two was expected to attenuate the difference between the two attributes (n=40 male. Analysis of the effects of IGT attribute type (intertemporal vs. frequency, sleep deprivation (sleep deprivation vs. no sleep deprivation, and test-retest gap (short vs. long showed a significant effect of IGT attribute type thus confirming the difference between the two attributes. Sleep deprivation had no effect on the attributes, but test-retest gap and the three-way interaction between attribute type, test-retest gap, and sleep deprivation were significant. Post-hoc tests showed sleep deprivation and short test-retest gap to attenuate the difference between the two attributes. As expected intertemporal decision making benefited from repeated task exposure. The findings add to understanding of the emotion-cognition dichotomy and show a time-dependent effect of a universally experienced constraint (sleep deprivation.

  18. Investigation of risk factors of psychological acceptance and burnout syndrome among nurses in China.

    Science.gov (United States)

    Yao, Yongcheng; Yao, Wu; Wang, Wei; Li, Hong; Lan, Yajia

    2013-10-01

    The objectives of this study were to determine reliability of Chinese version of Acceptance and Action Questionnaire-II (AAQ-II), the relationship between psychological acceptance (PA), and burnout syndrome and their risk factors among nurses in China. The reliability of AAQ-II in Chinese was evaluated first by testing on 111 doctors and 108 nurses in China. On the number of 845 nurses selected from nine city hospitals by using stratified cluster sampling method, the Maslach Burnout Inventory-General Survey was administered to establish the presence of burnout, and the AAQ-II was used to measure their PA. Results showed that the AAQ-II in Chinese had a good test-retest reliability. PA was statistically significantly negatively correlated to the three dimensionalities of burnout among nurses in China. Male and female nurses had a significant difference in PA. Risk factors for burnout were age (25-44 years), marital status (married), gender (male), hospital department (emergency) and position (primary title) as well as PA. The findings provide insights into the risk factors of burnout in Chinese nurses and may have clinical implications in preventing burnout in Chinese nurses. © 2013 Wiley Publishing Asia Pty Ltd.

  19. Test-retest reliability and longitudinal analysis of automated hippocampal subregion volumes in healthy ageing and Alzheimer's disease populations.

    Science.gov (United States)

    Worker, Amanda; Dima, Danai; Combes, Anna; Crum, William R; Streffer, Johannes; Einstein, Steven; Mehta, Mitul A; Barker, Gareth J; C R Williams, Steve; O'daly, Owen

    2018-04-01

    The hippocampal formation is a complex brain structure that is important in cognitive processes such as memory, mood, reward processing and other executive functions. Histological and neuroimaging studies have implicated the hippocampal region in neuropsychiatric disorders as well as in neurodegenerative diseases. This highly plastic limbic region is made up of several subregions that are believed to have different functional roles. Therefore, there is a growing interest in imaging the subregions of the hippocampal formation rather than modelling the hippocampus as a homogenous structure, driving the development of new automated analysis tools. Consequently, there is a pressing need to understand the stability of the measures derived from these new techniques. In this study, an automated hippocampal subregion segmentation pipeline, released as a developmental version of Freesurfer (v6.0), was applied to T1-weighted magnetic resonance imaging (MRI) scans of 22 healthy older participants, scanned on 3 separate occasions and a separate longitudinal dataset of 40 Alzheimer's disease (AD) patients. Test-retest reliability of hippocampal subregion volumes was assessed using the intra-class correlation coefficient (ICC), percentage volume difference and percentage volume overlap (Dice). Sensitivity of the regional estimates to longitudinal change was estimated using linear mixed effects (LME) modelling. The results show that out of the 24 hippocampal subregions, 20 had ICC scores of 0.9 or higher in both samples; these regions include the molecular layer, granule cell layer of the dentate gyrus, CA1, CA3 and the subiculum (ICC > 0.9), whilst the hippocampal fissure and fimbria had lower ICC scores (0.73-0.88). Furthermore, LME analysis of the independent AD dataset demonstrated sensitivity to group and individual differences in the rate of volume change over time in several hippocampal subregions (CA1, molecular layer, CA3, hippocampal tail, fissure and presubiculum

  20. Calf-raise senior: a new test for assessment of plantar flexor muscle strength in older adults: protocol, validity, and reliability.

    Science.gov (United States)

    André, Helô-Isa; Carnide, Filomena; Borja, Edgar; Ramalho, Fátima; Santos-Rocha, Rita; Veloso, António P

    2016-01-01

    This study aimed to develop a new field test protocol with a standardized measurement of strength and power in plantar flexor muscles targeted to functionally independent older adults, the calf-raise senior (CRS) test, and also evaluate its reliability and validity. Forty-one subjects aged 65 years and older of both sexes participated in five different cross-sectional studies: 1) pilot (n=12); 2) inter- and intrarater agreement (n=12); 3) construct (n=41); 4) criterion validity (n=33); and 5) test-retest reliability (n=41). Different motion parameters were compared in order to define a specifically designed protocol for seniors. Two raters evaluated each participant twice, and the results of the same individual were compared between raters and participants to assess the interrater and intrarater agreement. The validity and reliability studies involved three testing sessions that lasted 2 weeks, including a battery of functional fitness tests, CRS test in two occasions, accelerometry, and strength assessments in an isokinetic dynamometer. The CRS test presented an excellent test-retest reliability (intraclass correlation coefficient [ICC] =0.90, standard error of measurement =2.0) and interrater reliability (ICC =0.93-0.96), as well as a good intrarater agreement (ICC =0.79-0.84). Participants with better results in the CRS test were younger and presented higher levels of physical activity and functional fitness. A significant association between test results and all strength parameters (isometric, r =0.87, r 2 =0.75; isokinetic, r =0.86, r 2 =0.74; and rate of force development, r =0.77, r 2 =0.59) was shown. This study was successful in demonstrating that the CRS test can meet the scientific criteria of validity and reliability. The test can be a good indicator of ankle strength in older adults and proved to discriminate significantly between individuals with improved functionality and levels of physical activity.

  1. The Modified Reasons for Smoking Scale: factorial structure, validity and reliability in pregnant smokers.

    Science.gov (United States)

    De Wilde, Katrien Sophie; Tency, Inge; Boudrez, Hedwig; Temmerman, Marleen; Maes, Lea; Clays, Els

    2016-06-01

    Smoking during pregnancy can cause several maternal and neonatal health risks, yet a considerable number of pregnant women continue to smoke. The objectives of this study were to test the factorial structure, validity and reliability of the Dutch version of the Modified Reasons for Smoking Scale (MRSS) in a sample of smoking pregnant women and to understand reasons for continued smoking during pregnancy. A longitudinal design was performed. Data of 97 pregnant smokers were collected during prenatal consultation. Structural equation modelling was performed to assess the construct validity of the MRSS: an exploratory factor analysis was conducted, followed by a confirmatory factor analysis.Test-retest reliability (addiction, pleasure, habit and social function. Results for internal consistency and test-retest reliability were good to acceptable. There were significant associations of nicotine dependence with tension reduction and addiction and of daily consumption with addiction and habit. Validity and reliability of the MRSS were shown in a sample of pregnant smokers. Tension reduction was the most important reason for continued smoking, followed by pleasure and addiction. Although the score for nicotine dependence was low, addiction was an important reason for continued smoking during pregnancy; therefore, nicotine replacement therapy could be considered. Half of the respondents experienced depressive symptoms. Hence, it is important to identify those women who need more specialized care, which can include not only smoking cessation counselling but also treatment for depression. © 2016 John Wiley & Sons, Ltd.

  2. Reliability and validity of migraine disability assessment questionnaire-Thai version (Thai-MIDAS).

    Science.gov (United States)

    Seethong, Piman; Nimmannit, Akarin; Chaisewikul, Rungsan; Prayoonwiwat, Naraporn; Chotinaiwattarakul, Wattanachai

    2013-02-01

    To assess the validity and test-retest reliability of a Thai translation of the Migraine Disability Assessment (MIDAS) Questionnaire in Thai patients with migraine. Migraineurs from the Headache Clinic in Siriraj Hospital were recruited and asked to complete a 13-weeks diary and answered the Thai-MIDAS at once. Some participants were asked to provide the 2nd Thai-MIDAS in the next 2 weeks for test-retest reliability. Ninety-three patients had completed the 13-weeks diaries. Age range was 18-58 years with mean 37.69 +/- 9.60 years. All 5 items and the total score of Thai-MIDAS were moderately correlated with data from 13-weeks diary (Spearman's correlation coefficient = 0.32-0.62). The test-retest reliability of the total score of Thai-MIDAS in 30 patients demonstrated a highly reliable degree of intraclass correlation (ICC = 0.76, 95% CI 0.49-0.88). The present study reveals that the Thai-MIDAS has satisfactory validity and reliability in comparison with the original English MIDAS version.

  3. Hypertension Knowledge-Level Scale (HK-LS): A Study on Development, Validity and Reliability

    OpenAIRE

    Erkoc, Sultan Baliz; Isikli, Burhanettin; Metintas, Selma; Kalyoncu, Cemalettin

    2012-01-01

    This study was conducted to develop a scale to measure knowledge about hypertension among Turkish adults. The Hypertension Knowledge-Level Scale (HK-LS) was generated based on content, face, and construct validity, internal consistency, test re-test reliability, and discriminative validity procedures. The final scale had 22 items with six sub-dimensions. The scale was applied to 457 individuals aged ≥18 years, and 414 of them were re-evaluated for test-retest reliability. The six sub-dimensio...

  4. Measurement of acute nonspecific low back pain perception in primary care physical therapy: reliability and validity of the brief illness perception questionnaire.

    Science.gov (United States)

    Hallegraeff, Joannes M; van der Schans, Cees P; Krijnen, Wim P; de Greef, Mathieu H G

    2013-02-01

    The eight-item Brief Illness Perception Questionnaire is used as a screening instrument in physical therapy to assess mental defeat in patients with acute low back pain, besides patient perception might determine the course and risk for chronic low back pain. However, the psychometric properties of the Brief Illness Perception Questionnaire in common musculoskeletal disorders like acute low back pain have not been adequately studied. Patients' perceptions vary across different populations and affect coping styles. Thus, our aim was to determine the internal consistency, test-retest reliability and validity of the Dutch language version of the Brief Illness Perception Questionnaire in acute non-specific low back pain patients in primary care physical therapy. A non-experimental cross-sectional study with two measurements was performed. Eighty-four acute low back pain patients, in multidisciplinary health care center in Dutch primary care with a sample mean (SD) age of 42 (12) years, participated in the study. Internal consistency (Cronbach's α) and test-retest procedures (Intraclass Correlation Coefficients and limits of agreement) were evaluated at a one-week interval. The concurrent validity of the Brief Illness Perception Questionnaire was examined by using the Mental Health Component of the Short Form 36 Health Survey. The Cronbach's α for internal consistency was 0.73 (95% CI, 0.67 - 0.83); and the Intraclass Correlation Coefficient test-retest reliability was acceptable: 0.72 (95% CI, 0.53 - 0.82), however, the limits of agreement were large. The Intraclass Correlation Coefficient measuring concurrent validity 0.65 (95% CI, 0.46 - 0.80). The Dutch version of the Brief Illness Perception Questionnaire is an appropriate instrument for measuring patients' perceptions in acute low back pain patients, showing acceptable internal consistency and reliability. Concurrent validity is adequate, however, the instrument may be unsuitable for detecting changes in low

  5. Dual conception of risk in the Iowa Gambling Task: effects of sleep deprivation and test-retest gap.

    Science.gov (United States)

    Singh, Varsha

    2013-01-01

    Risk in the Iowa Gambling Task (IGT) is often understood in terms of intertemporal choices, i.e., preference for immediate outcomes in favor of delayed outcomes is considered risky decision making. According to behavioral economics, healthy decision makers are expected to refrain from choosing the short-sighted immediate gain because, over time (10 trials of the IGT), the immediate gains result in a long term loss (net loss). Instead decision makers are expected to maximize their gains by choosing options that, over time (10 trials), result in delayed or long term gains (net gain). However, task choices are sometimes made on the basis of the frequency of reward and punishment such that frequent rewards/infrequent punishments are favored over infrequent rewards/frequent punishments. The presence of these two attributes (intertemporality and frequency of reward) in IGT decision making may correspond to the emotion-cognition dichotomy and reflect a dual conception of risk. Decision making on the basis of the two attributes was tested under two conditions: delay in retest and sleep deprivation. An interaction between sleep deprivation and time delay was expected to attenuate the difference between the two attributes. Participants were 40 male university students. Analysis of the effects of IGT attribute type (intertemporal vs. frequency of reinforcement), sleep deprivation (sleep deprivation vs. no sleep deprivation), and test-retest gap (short vs. long delay) showed a significant within-subjects effect of IGT attribute type thus confirming the difference between the two attributes. Sleep deprivation had no effect on the attributes, but test-retest gap and the three-way interaction between attribute type, test-retest gap, and sleep deprivation were significantly different. Post-hoc tests revealed that sleep deprivation and short test-retest gap attenuated the difference between the two attributes. Furthermore, the results showed an expected trend of increase in

  6. Reliability and Validity of a New Method for Isometric Back Extensor Strength Evaluation Using A Hand-Held Dynamometer.

    Science.gov (United States)

    Park, Hee-Won; Baek, Sora; Kim, Hong Young; Park, Jung-Gyoo; Kang, Eun Kyoung

    2017-10-01

    To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65-0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was -63.1 N and the upper 95% LoA was 61.1 N. This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity.

  7. Validity and reliability of the novel thyroid-specific quality of life questionnaire, ThyPRO

    DEFF Research Database (Denmark)

    Watt, Torquil; Hegedüs, Laszlo; Groenvold, Mogens

    2010-01-01

    Background Appropriate scale validity and internal consistency reliability have recently been documented for the new thyroid-specific quality of life (QoL) patient-reported outcome (PRO) measure for benign thyroid disorders, the ThyPRO. However, before clinical use, clinical validity and test......-retest reliability should be evaluated. Aim To investigate clinical ('known-groups') validity and test-retest reliability of the Danish version of the ThyPRO. Methods For each of the 13 ThyPRO scales, we defined groups expected to have high versus low scores ('known-groups'). The clinical validity (known......-groups validity) was evaluated by whether the ThyPRO scales could detect expected differences in a cross-sectional study of 907 thyroid patients. Test-retest reliability was evaluated by intra-class correlations of two responses to the ThyPRO 2 weeks apart in a subsample of 87 stable patients. Results On all 13...

  8. Validity and reliability of a pictorial instrument for assessing perceived motor competence in Portuguese children.

    Science.gov (United States)

    Lopes, V P; Barnett, L M; Saraiva, L; Gonçalves, C; Bowe, S J; Abbott, G; Rodrigues, L P

    2016-09-01

    It is important to assess young children's perceived Fundamental Movement Skill (FMS) competence in order to examine the role of perceived FMS competence in motivation toward physical activity. Children's perceptions of motor competence may vary according to the culture/country of origin; therefore, it is also important to measure perceptions in different cultural contexts. The purpose was to assess the face validity, internal consistency, test-retest reliability and construct validity of the 12 FMS items in the Pictorial Scale for Perceived Movement Skill Competence for Young Children (PMSC) in a Portuguese sample. Two hundred one Portuguese children (girls, n = 112), 5 to 10 years of age (7.6 ± 1.4), participated. All children completed the PMSC once. Ordinal alpha assessed internal consistency. A random subsamples (n = 47) were reassessed one week later to determine test-retest reliability with Bland-Altman method. Children were asked questions after the second administration to determine face validity. Construct validity was assessed on the whole sample with a Bayesian Structural Equation Modelling (BSEM) approach. The hypothesized theoretical model used the 12 items and two hypothesized factors: object control and locomotor skills. The majority of children correctly identified the skills and could understand most of the pictures. Test-retest reliability analysis was good, with an agreement ration between 0.99 and 1.02. Ordinal alpha values ranged from acceptable (object control 0.73, locomotor 0.68) to good (all FMS 0.81). The hypothesized BSEM model had an adequate fit. The PMSC can be used to investigate perceptions of children's FMS competence. This instrument can also be satisfactorily used among Portuguese children. © 2016 John Wiley & Sons Ltd.

  9. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    Science.gov (United States)

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability. (c) 2015 APA, all rights reserved).

  10. The Vocal Cord Dysfunction Questionnaire: Validity and Reliability of the Persian Version.

    Science.gov (United States)

    Ghaemi, Hamide; Khoddami, Seyyedeh Maryam; Soleymani, Zahra; Zandieh, Fariborz; Jalaie, Shohreh; Ahanchian, Hamid; Khadivi, Ehsan

    2017-12-25

    The aim of this study was to develop, validate, and assess the reliability of the Persian version of Vocal Cord Dysfunction Questionnaire (VCDQ P ). The study design was cross-sectional or cultural survey. Forty-four patients with vocal fold dysfunction (VFD) and 40 healthy volunteers were recruited for the study. To assess the content validity, the prefinal questions were given to 15 experts to comment on its essential. Ten patients with VFD rated the importance of VCDQ P in detecting face validity. Eighteen of the patients with VFD completed the VCDQ 1 week later for test-retest reliability. To detect absolute reliability, standard error of measurement and smallest detected change were calculated. Concurrent validity was assessed by completing the Persian Chronic Obstructive Pulmonary Disease (COPD) Assessment Test (CAT) by 34 patients with VFD. Discriminant validity was measured from 34 participants. The VCDQ was further validated by administering the questionnaire to 40 healthy volunteers. Validation of the VCDQ as a treatment outcome tool was conducted in 18 patients with VFD using pre- and posttreatment scores. The internal consistency was confirmed (Cronbach α = 0.78). The test-retest reliability was excellent (intraclass correlation coefficient = 0.97). The standard error of measurement and smallest detected change values were acceptable (0.39 and 1.08, respectively). There was a significant correlation between the VCDQ P and the CAT total scores (P validity was significantly different. The VCDQ scores in patients with VFD before and after treatment was significantly different (P valid and reliable self-administered questionnaire in Persian-speaking population. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  11. Reliability, standard error, and minimum detectable change of clinical pressure pain threshold testing in people with and without acute neck pain.

    Science.gov (United States)

    Walton, David M; Macdermid, Joy C; Nielson, Warren; Teasell, Robert W; Chiasson, Marco; Brown, Lauren

    2011-09-01

    Clinical measurement. To evaluate the intrarater, interrater, and test-retest reliability of an accessible digital algometer, and to determine the minimum detectable change in normal healthy individuals and a clinical population with neck pain. Pressure pain threshold testing may be a valuable assessment and prognostic indicator for people with neck pain. To date, most of this research has been completed using algometers that are too resource intensive for routine clinical use. Novice raters (physiotherapy students or clinical physiotherapists) were trained to perform algometry testing over 2 clinically relevant sites: the angle of the upper trapezius and the belly of the tibialis anterior. A convenience sample of normal healthy individuals and a clinical sample of people with neck pain were tested by 2 different raters (all participants) and on 2 different days (healthy participants only). Intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable change were calculated. A total of 60 healthy volunteers and 40 people with neck pain were recruited. Intrarater reliability was almost perfect (ICC = 0.94-0.97), interrater reliability was substantial to near perfect (ICC = 0.79-0.90), and test-retest reliability was substantial (ICC = 0.76-0.79). Smaller change was detectable in the trapezius compared to the tibialis anterior. This study provides evidence that novice raters can perform digital algometry with adequate reliability for research and clinical use in people with and without neck pain.

  12. Reliability and validity of a smartphone pulse rate application for the assessment of resting and elevated pulse rate.

    Science.gov (United States)

    Mitchell, Katy; Graff, Megan; Hedt, Corbin; Simmons, James

    2016-08-01

    Purpose/hypothesis: This study was designed to investigate the test-retest reliability, concurrent validity, and the standard error of measurement (SEm) of a pulse rate assessment application (Azumio®'s Instant Heart Rate) on both Android® and iOS® (iphone operating system) smartphones as compared to a FT7 Polar® Heart Rate monitor. Number of subjects: 111. Resting (sitting) pulse rate was assessed twice and then the participants were asked to complete a 1-min standing step test and then immediately re-assessed. The smartphone assessors were blinded to their measurements. Test-retest reliability (intraclass correlation coefficient [ICC 2,1] and 95% confidence interval) for the three tools at rest (time 1/time 2): iOS® (0.76 [0.67-0.83]); Polar® (0.84 [0.78-0.89]); and Android® (0.82 [0.75-0.88]). Concurrent validity at rest time 2 (ICC 2,1) with the Polar® device: IOS® (0.92 [0.88-0.94]) and Android® (0.95 [0.92-0.96]). Concurrent validity post-exercise (time 3) (ICC) with the Polar® device: iOS® (0.90 [0.86-0.93]) and Android® (0.94 [0.91-0.96]). The SEm values for the three devices at rest: iOS® (5.77 beats per minute [BPM]), Polar® (4.56 BPM) and Android® (4.96 BPM). The Android®, iOS®, and Polar® devices showed acceptable test-retest reliability at rest and post-exercise. Both the smartphone platforms demonstrated concurrent validity with the Polar® at rest and post-exercise. The Azumio® Instant Heart Rate application when used by either platform appears to be a reliable and valid tool to assess pulse rate in healthy individuals.

  13. Reliability, validity, and responsiveness of the Persian version of Shoulder Activity Scale in a group of patients with shoulder disorders.

    Science.gov (United States)

    Negahban, Hossein; Mohtasebi, Elham; Goharpey, Shahin

    2015-01-01

    The aim of this methodological study was to cross-culturally translate the Shoulder Activity Scale (SAS) into the Persian and determine its clinimetric properties including reliability, validity, and responsiveness in patients with shoulder disorders. Persian version of the SAS was obtained after standard forward-backward translation. Three questionnaires were completed by the respondents: SAS, shoulder pain and disability index (SPADI), and Short-Form 36 Health Survey (SF-36). The patients completed the SAS, 1 week after the first visit to evaluate the test-retest reliability. Construct validity was evaluated by examining the associations between the scores on the SAS and the scores obtained from the SPADI, SF-36, and age of the patients. To assess responsiveness, data were collected in the first visit and then again after 4 weeks physiotherapy intervention. Test-retest reliability and internal consistency were assessed using Intra-class Correlation Coefficient (ICC) and Cronbach's alpha, respectively. To evaluate construct validity, Spearman's rank correlation was used. The ability of the SAS to detect changes was evaluated by the receiver-operating characteristics method. No problem or language difficulties were reported during translation process. Test-retest reliability of the SAS was excellent with an ICC of 0.98. Also, the marginal Cronbach's alpha level of 0.64 was obtained. The correlation between the SAS and the SPADI was low, proving divergent validity, whereas the correlations between the SAS and the SF-36/age were moderate proving convergent validity. A marginally acceptable responsiveness was achieved for the Persian SAS. The study provides some evidences to support the test-retest reliability, internal consistency, construct validity, and responsiveness of the Persian version of the SAS in patients with shoulder disorders. Therefore, it seems that this instrument is a useful measure of shoulder activity level in research setting and clinical practice

  14. Test-Retest Reliability of Standard and Emotional Stroop Tasks: An Investigation of Color-Word and Picture-Word Versions

    Science.gov (United States)

    Strauss, Gregory P.; Allen, Daniel N.; Jorgensen, Melinda L.; Cramer, Stacey L.

    2005-01-01

    Previous studies have examined the reliability of scores derived from various Stroop tasks. However, few studies have compared reliability of more recently developed Stroop variants such as emotional Stroop tasks to standard versions of the Stroop. The current study developed four different single-stimulus Stroop tasks and compared test-retest…

  15. Measuring reliable change in cognition using the Edinburgh Cognitive and Behavioural ALS Screen (ECAS).

    Science.gov (United States)

    Crockford, Christopher; Newton, Judith; Lonergan, Katie; Madden, Caoifa; Mays, Iain; O'Sullivan, Meabhdh; Costello, Emmet; Pinto-Grau, Marta; Vajda, Alice; Heverin, Mark; Pender, Niall; Al-Chalabi, Ammar; Hardiman, Orla; Abrahams, Sharon

    2018-02-01

    Cognitive impairment affects approximately 50% of people with amyotrophic lateral sclerosis (ALS). Research has indicated that impairment may worsen with disease progression. The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) was designed to measure neuropsychological functioning in ALS, with its alternate forms (ECAS-A, B, and C) allowing for serial assessment over time. The aim of the present study was to establish reliable change scores for the alternate forms of the ECAS, and to explore practice effects and test-retest reliability of the ECAS's alternate forms. Eighty healthy participants were recruited, with 57 completing two and 51 completing three assessments. Participants were administered alternate versions of the ECAS serially (A-B-C) at four-month intervals. Intra-class correlation analysis was employed to explore test-retest reliability, while analysis of variance was used to examine the presence of practice effects. Reliable change indices (RCI) and regression-based methods were utilized to establish change scores for the ECAS alternate forms. Test-retest reliability was excellent for ALS Specific, ALS Non-Specific, and ECAS Total scores of the combined ECAS A, B, and C (all > .90). No significant practice effects were observed over the three testing sessions. RCI and regression-based methods produced similar change scores. The alternate forms of the ECAS possess excellent test-retest reliability in a healthy control sample, with no significant practice effects. The use of conservative RCI scores is recommended. Therefore, a change of ≥8, ≥4, and ≥9 for ALS Specific, ALS Non-Specific, and ECAS Total score is required for reliable change.

  16. Reliability of a computer software angle tool for measuring spine and pelvic flexibility during the sit-and-reach test.

    Science.gov (United States)

    Mier, Constance M; Shapiro, Belinda S

    2013-02-01

    The purpose of this study was to determine the reliability of a computer software angle tool that measures thoracic (T), lumbar (L), and pelvic (P) angles as a means of evaluating spine and pelvic flexibility during the sit-and-reach (SR) test. Thirty adults performed the SR twice on separate days. The SR test was captured on video and later analyzed for T, L, and P angles using the computer software angle tool. During the test, 3 markers were placed over T1, T12, and L5 vertebrae to identify T, L, and P angles. Intraclass correlation coefficient (ICC) indicated a very high internal consistency (between trials) for T, L, and P angles (0.95-0.99); thus, the average of trials was used for test-retest (between days) reliability. Mean (±SD) values did not differ between days for T (51.0 ± 14.3 vs. 52.3 ± 16.2°), L (23.9 ± 7.1 vs. 23.0 ± 6.9°), or P (98.4 ± 15.6 vs. 98.3 ± 14.7°) angles. Test-retest reliability (ICC) was high for T (0.96) and P (0.97) angles and moderate for L angle (0.84). Both intrarater and interrater reliabilities were high for T (0.95, 0.94) and P (0.97, 0.97) angles and moderate for L angle (0.87, 0.82). Thus, the computer software angle tool is a highly objective method for assessing spine and pelvic flexibility during a video-captured SR test.

  17. Sense of competence in dementia care staff (SCIDS) scale: development, reliability, and validity.

    Science.gov (United States)

    Schepers, Astrid Kristine; Orrell, Martin; Shanahan, Niamh; Spector, Aimee

    2012-07-01

    Sense of competence in dementia care staff (SCIDS) may be associated with more positive attitudes to dementia among care staff and better outcomes for those being cared for. There is a need for a reliable and valid measure of sense of competence specific to dementia care staff. This study describes the development and evaluation of a measure to assess "sense of competence" in dementia care staff and reports on its psychometric properties. The systematic measure development process involved care staff and experts. For item selection and assessment of psychometric properties, a pilot study (N = 37) and a large-scale study (N = 211) with a test-retest reliability (N = 58) sub-study were undertaken. The final measure consists of 17 items across four subscales with acceptable to good internal consistency and moderate to substantial test-retest reliability. As predicted, the measure was positively associated with work experience, job satisfaction, and person-centered approaches to dementia care, giving a first indication for its validity. The SCIDS scale provides a useful and user-friendly means of measuring sense of competence in care staff. It has been developed using a robust process and has adequate psychometric properties. Further exploration of the construct and the scale's validity is warranted. It may be useful to assess the impact of training and perceived abilities and skills in dementia care.

  18. Validity and Reliability of Persian Version of Onyx Social Capital Scale in Elderly People

    Directory of Open Access Journals (Sweden)

    Reza Eftekharian

    2016-04-01

    Conclusion: The Persian version of the questionnaire for this population has acceptable levels of face validity based on clarity, simplicity, and understandability of the questions, answers, and explanations of the Persian version of the social capital questionnaire. This version of the questionnaire also had acceptable levels in terms of suitability of the translation of the questionnaire, its suitability for Iranian community, its understandability, and suitability for needs assessment, discriminate validity (the internal consistency of the Persian version of questionnaire, test-retest reliability (absolute, and relative, and internal consistency. Therefore, this instrument is suitable for evaluating the level of social capital among the Iranian elderly people.

  19. Reliability and normative values of the foot line test: a technique to assess foot posture

    DEFF Research Database (Denmark)

    Brushøj, C; Larsen, Klaus; Nielsen, MB

    2007-01-01

    STUDY DESIGN: Test-retest reliability. OBJECTIVE: To examine the reliability and report normative values of a novel test, the foot line test (FLT), to describe foot morphology. BACKGROUND: Numerous foot examinations are performed each day, but most existing examination techniques have considerable...... limitations regarding reliability and validity. METHODS: One hundred thirty subjects with mean foot size 44 (41-50 European size) participated. Two examiners, blinded to each other's measurements, measured the right foot of the subjects twice and the left foot once. The position of the most medial aspect...... of the navicular in the mediolateral direction was projected vertically onto a piece of paper placed under the subject's foot, and compared to the position of the forefoot and hindfoot to obtain the FLT value. RESULTS: FLT values ranged from -8 to 14 mm, with a mean (+/-SD) of 3.7 +/- 3.4 mm. The intratester...

  20. What to Do With "Moderate" Reliability and Validity Coefficients?

    NARCIS (Netherlands)

    Post, Marcel W

    Clinimetric studies may use criteria for test-retest reliability and convergent validity such that correlation coefficients as low as .40 are supportive of reliability and validity. It can be argued that moderate (.40-.60) correlations should not be interpreted in this way and that reliability

  1. Validity and Reliability Study of the Korean Tinetti Mobility Test for Parkinson's Disease.

    Science.gov (United States)

    Park, Jinse; Koh, Seong-Beom; Kim, Hee Jin; Oh, Eungseok; Kim, Joong-Seok; Yun, Ji Young; Kwon, Do-Young; Kim, Younsoo; Kim, Ji Seon; Kwon, Kyum-Yil; Park, Jeong-Ho; Youn, Jinyoung; Jang, Wooyoung

    2018-01-01

    Postural instability and gait disturbance are the cardinal symptoms associated with falling among patients with Parkinson's disease (PD). The Tinetti mobility test (TMT) is a well-established measurement tool used to predict falls among elderly people. However, the TMT has not been established or widely used among PD patients in Korea. The purpose of this study was to evaluate the reliability and validity of the Korean version of the TMT for PD patients. Twenty-four patients diagnosed with PD were enrolled in this study. For the interrater reliability test, thirteen clinicians scored the TMT after watching a video clip. We also used the test-retest method to determine intrarater reliability. For concurrent validation, the unified Parkinson's disease rating scale, Hoehn and Yahr staging, Berg Balance Scale, Timed-Up and Go test, 10-m walk test, and gait analysis by three-dimensional motion capture were also used. We analyzed receiver operating characteristic curve to predict falling. The interrater reliability and intrarater reliability of the Korean Tinetti balance scale were 0.97 and 0.98, respectively. The interrater reliability and intra-rater reliability of the Korean Tinetti gait scale were 0.94 and 0.96, respectively. The Korean TMT scores were significantly correlated with the other clinical scales and three-dimensional motion capture. The cutoff values for predicting falling were 14 points (balance subscale) and 10 points (gait subscale). We found that the Korean version of the TMT showed excellent validity and reliability for gait and balance and had high sensitivity and specificity for predicting falls among patients with PD.

  2. Test of cure, retesting and extragenital testing practices for Chlamydia trachomatis and Neisseria gonorrhoeae among general practitioners in different socioeconomic status areas: A retrospective cohort study, 2011-2016

    Science.gov (United States)

    van Liere, Geneviève A. F. S.; Cals, Jochen W. L.; Dukers-Muijrers, Nicole H. T. M.

    2018-01-01

    Background For Chlamydia trachomatis (CT), a test of cure (TOC) within 3–5 weeks is not recommended. International guidelines differ in advising a Neisseria gonorrhoeae (NG) TOC. Retesting CT and NG positives within 3–12 months is recommended in international guidelines. We assessed TOC and retesting practices including extragenital testing in general practitioner (GP) practices located in different socioeconomic status (SES) areas to inform and optimize local test practices. Methods Laboratory data of 48 Dutch GP practices between January 2011 and July 2016 were used. Based on a patient’s first positive CT or NG test, the proportion of TOC (TOC and 24% had a retest at the GP practice. GP practices in low SES areas were more likely to perform a CT TOC (OR:1.8;95%CI:1.1–3.1). Younger patients (TOC (OR:1.6;95%CI:1.0–2.4). For CT (n = 622), 2.4% had a TOC and 6.1% had a retest at another STI care provider. For NG (n = 73), 25% had a TOC and 15% had a retest at the GP practice. For NG (n = 73), 2.7% had a TOC and 12.3% had a retest at another STI care provider. In only 0.3% of the consultations patients were tested on extragenital sites. Conclusion Almost 20% of the patients returned for a CT TOC, especially at GP practices in low SES areas. For NG, 1 out of 4 patients returned for a TOC. Retesting rates were low for both CT (24%) and NG (15%), (re)infections including extragenital infections may be missed. Efforts are required to focus TOC and increase retesting practices of GPs in order to improve CT/NG control. PMID:29538469

  3. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Reliability of instruments in a cooperative, multisite study: employment intervention demonstration program.

    Science.gov (United States)

    Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T

    2001-09-01

    Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.

  5. Reliability and validity of psychosocial and environmental correlates measures of physical activity and screen-based behaviors among Chinese children in Hong Kong

    Directory of Open Access Journals (Sweden)

    Salmon Jo

    2011-03-01

    Full Text Available Abstract Background Insufficient participation in physical activity and excessive screen time have been observed among Chinese children. The role of social and environmental factors in shaping physical activity and sedentary behaviors among Chinese children is under-investigated. The purpose of the present study was to assess the reliability and validity of a questionnaire to measure child- and parent-reported psychosocial and environmental correlates of physical activity and screen-based behaviors among Chinese children in Hong Kong. Methods A total of 303 schoolchildren aged 9-14 years and their parents volunteered to participate in this study and 160 of them completed the questionnaire twice within an interval of 10 days. Intraclass correlation coefficients (ICCs, kappa statistics, and percent agreement were performed to evaluate test-retest reliability of the continuous and categorical variables, respectively. Exploratory factor analyses (EFAs were conducted to assess convergent validity of the emergent scales. Cronbach's alpha and ICCs were performed to assess internal and test-retest reliability of the emergent scales. Criterion validity was assessed by correlating psychosocial and environmental measures with self-reported physical activity and screen-based behaviors, measured by a validated questionnaire. Results Reliability statistics for both child- and parent-reported continuous variables showed acceptable consistency for all of the ICC values greater than 0.70. Kappa statistics showed fair to perfect test-retest reliability for the categorical items. Adequate internal consistency and test-retest reliability were observed in most of the emergent scales. Criterion validity assessed by correlating psychosocial and environmental measures with child-reported physical activity found associations with physical activity in the self-efficacy scale (r = 0.25, P r = 0.25, P r = 0.14, P r = -0.22, P r = 0.12, P = 0.053. Conclusions The findings

  6. Test-Retest Reliability of an Experienced Global Trigger Tool Review Team

    DEFF Research Database (Denmark)

    Bjørn, Brian; Anhøj, Jacob; Østergaard, Mette

    2018-01-01

    and review 2 and between period 1 and period 2. The increase was solely in category E, minor temporary harm. CONCLUSIONS: The very experienced GTT team could not reproduce harm rates found in earlier reviews. We conclude that GTT in its present form is not a reliable measure of harm rate over time....

  7. Preliminary psychometric properties of the Acceptance and Action Questionnaire-II: a revised measure of psychological inflexibility and experiential avoidance.

    Science.gov (United States)

    Bond, Frank W; Hayes, Steven C; Baer, Ruth A; Carpenter, Kenneth M; Guenole, Nigel; Orcutt, Holly K; Waltz, Tom; Zettle, Robert D

    2011-12-01

    The present research describes the development and psychometric evaluation of a second version of the Acceptance and Action Questionnaire (AAQ-II), which assesses the construct referred to as, variously, acceptance, experiential avoidance, and psychological inflexibility. Results from 2,816 participants across six samples indicate the satisfactory structure, reliability, and validity of this measure. For example, the mean alpha coefficient is .84 (.78-.88), and the 3- and 12-month test-retest reliability is .81 and .79, respectively. Results indicate that AAQ-II scores concurrently, longitudinally, and incrementally predict a range of outcomes, from mental health to work absence rates, that are consistent with its underlying theory. The AAQ-II also demonstrates appropriate discriminant validity. The AAQ-II appears to measure the same concept as the AAQ-I (r=.97) but with better psychometric consistency. Copyright © 2011. Published by Elsevier Ltd.

  8. Reliability and validity of Yo-Yo tests in 9- to 16-year-old football players and matched non-sports active schoolboys

    DEFF Research Database (Denmark)

    Póvoas, Susana C A; Castagna, Carlo; Soares, José M C

    2016-01-01

    The purpose of this study was to examine the test-retest reliability and construct validity of three age-adapted Yo-Yo intermittent tests in football players aged 9-16 years (n = 70) and in age-matched non-sports active boys (n = 72). Within 7 days, each participant performed two repetitions...... performances and HRpeak are reliable for 9- to 16-year-old footballers and non-sports active boys. Additionally, performances of the three Yo-Yo tests were seemingly better for football-trained than for non-sports active boys, providing evidence of construct validity....

  9. The validity and reliability of the Moroccan version of the Revised Fibromyalgia Impact Questionnaire.

    Science.gov (United States)

    Srifi, Najlaa; Bahiri, Rachid; Rostom, Samira; Bendeddouche, Imad; Lazrek, Noufissa; Hajjaj-Hassouni, Najia

    2013-01-01

    The Revised Fibromyalgia Impact Questionnaire (FIQ-R) is an updated version of the FIQ attempts to address the limitations of the Fibromyalgia Impact Questionnaire (FIQ). As there is no Moroccan version of the FIQ-R available, we aimed to investigate the validity and reliability of a Moroccan translation of the FIQR in Moroccan fibromyalgia (FM) patients. After translating the FIQR into Moroccan, it was administered to 80 patients with FM. All of the patients filled out the questionnaire together with Arabic version of short form-36 (SF-36). The tender-point count was calculated from tender points identified by thumb palpation. Three days later, FM patients filled out the Moroccan FIQR at their second visit. The test-retest reliability of the Moroccan FIQR questions ranged from 0.72 to 0.87. The test and retest reliability of total FIQR score was 0.84. Cronbach's alpha was 0.91 for FIQR visit 1 (the first assessment) and 0.92 for FIQR visit 2 (the second assessment), indicating acceptable levels of internal consistency for both assessments. Significant correlations for construct validity were obtained between the Moroccan FIQ-R total and domain scores and the subscales of the SF-36 (FIQR total versus SF-36 physical component score and mental component score were r = -0.69, P FIQ-R showed adequate reliability and validity. This instrument can be used in the clinical evaluation of Moroccan and Arabic-speaking patients with FM.

  10. Development, reliability and validity of the psychosocial adaptation scale for Parkinson's disease in Chinese population.

    Science.gov (United States)

    Zhang, Tingting; Yin, Anchun; Sun, Xiaohong; Liu, Qigui; Song, Guirong; Li, Lianhong

    2015-01-01

    To develop psychosocial adaptation scale for Parkinson's disease (PD) in Chinese population and evaluate its reliability and validity. The items were designed by literature review, expert consultation and semi-structured interview. The methods of corrected item-total correlation, discrimination analysis and exploratory factor analysis were used for items selection. 427 valid scales from PD patients were collected in the study to test the reliability and validity. The scale incorporated six dimensions: anxiety, self-esteem, attitude, self-acceptance, self-efficacy and social support, a total of 32 items. The scale possessed good internal consistency. The test-retest correlation coefficient was 0.99 and average content validation rate was 0.97. The Hoehn and Yahr stage were correlated with total score of the scale. The psychosocial adaptation scale in this study showed good reliability and validity, it can be used as a reliable and valid instrument to evaluate the psychosocial adaptation of PD objectively and effectively.

  11. Processes and Procedures for Estimating Score Reliability and Precision

    Science.gov (United States)

    Bardhoshi, Gerta; Erford, Bradley T.

    2017-01-01

    Precision is a key facet of test development, with score reliability determined primarily according to the types of error one wants to approximate and demonstrate. This article identifies and discusses several primary forms of reliability estimation: internal consistency (i.e., split-half, KR-20, a), test-retest, alternate forms, interscorer, and…

  12. Reliability and validity of a nutrition and physical activity environmental self-assessment for child care

    Directory of Open Access Journals (Sweden)

    Ammerman Alice S

    2007-07-01

    Full Text Available Abstract Background Few assessment instruments have examined the nutrition and physical activity environments in child care, and none are self-administered. Given the emerging focus on child care settings as a target for intervention, a valid and reliable measure of the nutrition and physical activity environment is needed. Methods To measure inter-rater reliability, 59 child care center directors and 109 staff completed the self-assessment concurrently, but independently. Three weeks later, a repeat self-assessment was completed by a sub-sample of 38 directors to assess test-retest reliability. To assess criterion validity, a researcher-administered environmental assessment was conducted at 69 centers and was compared to a self-assessment completed by the director. A weighted kappa test statistic and percent agreement were calculated to assess agreement for each question on the self-assessment. Results For inter-rater reliability, kappa statistics ranged from 0.20 to 1.00 across all questions. Test-retest reliability of the self-assessment yielded kappa statistics that ranged from 0.07 to 1.00. The inter-quartile kappa statistic ranges for inter-rater and test-retest reliability were 0.45 to 0.63 and 0.27 to 0.45, respectively. When percent agreement was calculated, questions ranged from 52.6% to 100% for inter-rater reliability and 34.3% to 100% for test-retest reliability. Kappa statistics for validity ranged from -0.01 to 0.79, with an inter-quartile range of 0.08 to 0.34. Percent agreement for validity ranged from 12.9% to 93.7%. Conclusion This study provides estimates of criterion validity, inter-rater reliability and test-retest reliability for an environmental nutrition and physical activity self-assessment instrument for child care. Results indicate that the self-assessment is a stable and reasonably accurate instrument for use with child care interventions. We therefore recommend the Nutrition and Physical Activity Self-Assessment for

  13. Reliability and Validity of the Temperament and Character Inventory

    Directory of Open Access Journals (Sweden)

    Mahboubeh Dadfar

    2010-10-01

    Full Text Available Objective: The Temperament and Character Inventory (TCI was developed to assess temperament including Novelty Seeking (NS, Harm Avoidance (HA, Reward Dependence (RD, Persistence (PS, and Character including Self-Directedness (SD, Cooperativeness (CO and Self Transcendence (ST dimensions of Cloninger's biopsychosocial model of personality in adults. The purpose of this study was to evaluate the reliability and validity of this inventory. Materials & Methods: In this validity test and standardization study, after translation of TCI into Farsi and back translation, the final form was prepared and administered to 220 students who were selected via simple sampling. Cronbach's alpha procedure and test-retest method was used to assess the reliability, and factor analysis of promax rotation was utilized to determine the validity of the inventory. Correlation of interscales and age with scales of TCI was calculated by Pearson correlation. A comparison of TCI scores between sex and also cross-cultural was down using independent t-test. Results: The alpha cofficients for the inventory ranged from 0.44 for the Persistence scale to 0.81 for the ST scale with a median 0f 0.68. The overall alpha cofficients for the whole inventory was 0.74. The Pearson correlation cofficient for the test-retest on 31 students after two months ranged from 0.53 for Novelty Seeking and Persistence to 0.82 for Harm Avoidance scales and from 0.24 for disorderliness vs regimentation (NS4 to 0.86 for fear of uncertainty vs self-confidene (HA2 subscales. The factor analysis showed six factors. Significant correlations were obtained between scales of Self–Directedness with Harm Avoidance (0.57, Self–Directedness with Cooperativeness (0.46. Conclusion: The current study confirms that Persian version of the Temperament and Character Inventory has satisfactory psychometric properties and acceptable reliability and validity for the use students of university population.

  14. Identification of conductive hearing loss using air conduction tests alone: reliability and validity of an automatic test battery.

    Science.gov (United States)

    Convery, Elizabeth; Keidser, Gitte; Seeto, Mark; Freeston, Katrina; Zhou, Dan; Dillon, Harvey

    2014-01-01

    The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary according to hearing loss type. A secondary objective was to evaluate the reliability and validity of a novel automatic audiometry algorithm to assess its suitability for inclusion in the test battery. Participants underwent a series of hearing assessments that were conducted in a randomized order: manual pure-tone air conduction audiometry and bone conduction audiometry; automatic pure-tone air conduction audiometry; and an automatic tone-in-noise detection task. The automatic tests were each administered twice. The ability of the automatic test battery to: (a) predict the presence of an air-bone gap (ABG); and (b) accurately measure AC hearing thresholds was assessed against the results of manual audiometry. Test-retest conditions were compared to determine the reliability of each component of the automatic test battery. Data were collected on 120 ears from normal-hearing and conductive, sensorineural, and mixed hearing-loss subgroups. Performance differences between different types of hearing loss were observed. Ears with a conductive component (conductive and mixed ears) tended to have normal signal to noise ratios (SNR) despite impaired thresholds in quiet, while ears without a conductive component (normal and sensorineural ears) demonstrated, on average, an increasing relationship between their thresholds in quiet and their achieved SNR. Using the relationship between these two measures among ears with no conductive component as a benchmark, the likelihood that an ear has a conductive component can be estimated based on the deviation from this benchmark. The sensitivity and

  15. Content validity and reliability of test of gross motor development in Chilean children

    Directory of Open Access Journals (Sweden)

    Marcelo Cano-Cappellacci

    2015-01-01

    Full Text Available ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2 for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.

  16. Evidence of Reliability for Persian Version of the “Cumberland Ankle Instability Tool (CAIT” in Iranian Athletes with lateral Ankle Sprain

    Directory of Open Access Journals (Sweden)

    Mitra Haji-Maghsoudi

    2016-01-01

    Full Text Available Objectives: The purpose of the present study was to evaluate the reliability of persian version of the “Cumberland Ankle Instability Tool (CAIT” in Iranian athletes with lateral ankle sprain. Matterials & Methods: The present study is a methodological and non-experimental study. After forward and backward translation of CAIT, 46 athletes were selected with convenient nonprobably sampling from Physical Education Faculty of Tehran university and Taekwondo Club. Questionnaire was given to participants who experienced at least one lateral ankle sprain based on doctor’s diagnosis. In the second phase (one week later the questionnaire was distributed among the participants again to test the reliability of the measured between the two tests. After collecting the data, the test-retest reliability of  Persian version of the questionnaire was evaluated by calculating the intraclass correlation coefficient, standard error of measurement, smallest detectable change and Cronbach’s alpha coefficients were calculated to assess the internal consistency of the questionnaire’s items. Results Cronbach’s alpha was 0.64, which is close to acceptable level of internal consistency (0.7-0.95. Factor analysis showed that questionnaires’ items can be classified  in 4 categories with maximum of 72% variance cover. The test-retest correlation coefficient ICC for the total score of CAIT was 0.95 (P>100.0, indicating excellent reproducibility of the Persian version of the questionnaire. The standard error of measurement (SEM was 1 and the smallest acceptable change (SDC was 2.76 with 95% confidence. Conclusion: The results show that the Persian version of the CAIT can be used in athletes with functional ankle instability as a reliable tool to detect instability and assess changes caused by therapeutic interventions.

  17. Reliability of tonosafe disposable tonometer prisms: clinical implications from the Veterans Affairs Boston Healthcare System Quality Assurance Study.

    Science.gov (United States)

    Thomas, V; Daly, M K; Cakiner-Egilmez, T; Baker, E

    2011-05-01

    Given the Veterans Affairs Boston Healthcare System's recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting. Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test-retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements. The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3-34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=-1.05 was significantly different from the hypothesized value. The Tonosafe test-retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability. The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings.

  18. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  19. The Vocal Tract Discomfort Scale: Validity and Reliability of the Persian Version in the Assessment of Patients With Muscle Tension Dysphonia.

    Science.gov (United States)

    Torabi, Hadi; Khoddami, Seyyedeh Maryam; Ansari, Noureddin Nakhostin; Dabirmoghaddam, Payman

    2016-11-01

    To cross-culturally adapt of Persian Vocal Tract Discomfort (VTDp) scale and evaluate its validity and reliability in the assessment of patients with muscle tension dysphonia (MTD). A cross-sectional and prospective cohort design was used to psychometrically test the VTDp. The VTD scale was cross-culturally adapted into Persian language following standard forward-backward translations. The VTDp scale was administrated to 100 patients with MTD (54 men and 46 women; mean age: 38.05 ± 10.02 years) and 50 healthy volunteers (26 men and 24 women; mean age: 36.50 ± 12.27 years). Forty-five patients with MTD completed the VTDp 7 days later for test-retest reliability. Patients also completed the Persian Voice Handicap Index (VHIp) to assess construct validity. The results of discriminative validity demonstrated that the VTDp was able to discriminate between patients with MTD and healthy participants. The internal consistency was confirmed with Cronbach α .77 and 0.73 for VTDp frequency and severity subscales, respectively. The test-retest reliability was excellent with an intraclass correlation coefficient (ICC agreement ) of 0.93 for the frequency subscale and 0.91 for the severity subscale. Construct validity of the VTDp was shown with significant correlations between the VTDp frequency and severity subscales and the VHIp total scores (0.36 and 0.37, respectively). The standard error of measurement and smallest detectable change values for VTDp frequency (2.11 and 5.85, respectively) and severity (2.25 and 6.23, respectively) were acceptable. The Bland-Altman analysis for assessing the agreement between test and retest measurements showed no systematic bias. The VTDp is a valid and reliable self-administered scale to measure patient's vocal tract sensations in Persian-speaking population. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  20. Development, construct validity and test–retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, AMH; Hoozemans, MJM; Berger, MAM; van der Slikke, R.M.A.; van der Woude, LHV; Veeger, H.E.J.

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation

  1. Development, construct validity and test–retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M H; Hoozemans, Marco J M; Berger, Monique A M; van der Slikke, Rienk M A; van der Woude, Lucas H V; Veeger, Dirkjan (H E J)

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  2. Development, reliability and validity of the psychosocial adaptation scale for Parkinson’s disease in Chinese population

    Science.gov (United States)

    Zhang, Tingting; Yin, Anchun; Sun, Xiaohong; Liu, Qigui; Song, Guirong; Li, Lianhong

    2015-01-01

    Objective: To develop psychosocial adaptation scale for Parkinson’s disease (PD) in Chinese population and evaluate its reliability and validity. Methods: The items were designed by literature review, expert consultation and semi-structured interview. The methods of corrected item-total correlation, discrimination analysis and exploratory factor analysis were used for items selection. 427 valid scales from PD patients were collected in the study to test the reliability and validity. Results: The scale incorporated six dimensions: anxiety, self-esteem, attitude, self-acceptance, self-efficacy and social support, a total of 32 items. The scale possessed good internal consistency. The test-retest correlation coefficient was 0.99 and average content validation rate was 0.97. The Hoehn and Yahr stage were correlated with total score of the scale. Conclusions: The psychosocial adaptation scale in this study showed good reliability and validity, it can be used as a reliable and valid instrument to evaluate the psychosocial adaptation of PD objectively and effectively. PMID:26770638

  3. Reliability and Validity of Colored Progressive Matrices for 4-6 Age Children

    Directory of Open Access Journals (Sweden)

    Ahmet Bildiren

    2017-06-01

    Full Text Available In this research, it was aimed to test the reliability and validity of Colored Progressive Matrices for children between the ages of 4 to 6 from 15 schools. The sample of the study consisted of 640 kindergarten children. Test-retest and parallel form were used for reliability analyses. For the validity analysis, the relations between the Colored Progressive Matrices Test and Bender Gestalt Visual Motor Sensitivity Test, WISC-R and TONI-3 tests were examined. The results showed that there was a significant relation between the test-retest results and the parallel forms in all the age groups. Validity analyses showed strong correlations between the Colored Progressive Matrices and all the other measures.

  4. NDE reliability gains from combining eddy-current and ultrasonic testing

    International Nuclear Information System (INIS)

    Horn, D.; Mayo, W.R.

    1999-01-01

    We investigate statistical methods for combining the results of two complementary inspection techniques, eddy-current and ultrasonic testing. The reliability of rejection/acceptance decisions based on combined information is compared with that based on each inspection technique individually. The measured reliability increases with the amount of information incorporated in the decision. (author)

  5. Developing Reliable Life Support for Mars

    Science.gov (United States)

    Jones, Harry W.

    2017-01-01

    A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and

  6. Development of Physical Activity-Related Parenting Practices Scales for Urban Chinese Parents of Preschoolers: Confirmatory Factor Analysis and Reliability.

    Science.gov (United States)

    Suen, Yi-Nam; Cerin, Ester; Barnett, Anthony; Huang, Wendy Y J; Mellecker, Robin R

    2017-09-01

    Valid instruments of parenting practices related to children's physical activity (PA) are essential to understand how parents affect preschoolers' PA. This study developed and validated a questionnaire of PA-related parenting practices for Chinese-speaking parents of preschoolers in Hong Kong. Parents (n = 394) completed a questionnaire developed using findings from formative qualitative research and literature searches. Test-retest reliability was determined on a subsample (n = 61). Factorial validity was assessed using confirmatory factor analysis. Subscale internal consistency was determined. The scale of parenting practices encouraging PA comprised 2 latent factors: Modeling, structure and participatory engagement in PA (23 items), and Provision of appropriate places for child's PA (4 items). The scale of parenting practices discouraging PA scale encompassed 4 latent factors: Safety concern/overprotection (6 items), Psychological/behavioral control (5 items), Promoting inactivity (4 items), and Promoting screen time (2 items). Test-retest reliabilities were moderate to excellent (0.58 to 0.82), and internal subscale reliabilities were acceptable (0.63 to 0.89). We developed a theory-based questionnaire for assessing PA-related parenting practices among Chinese-speaking parents of Hong Kong preschoolers. While some items were context and culture specific, many were similar to those previously found in other populations, indicating a degree of construct generalizability across cultures.

  7. The Locomotor Capabilities Index; validity and reliability of the Swedish version in adults with lower limb amputation

    Directory of Open Access Journals (Sweden)

    Andersson Ingemar H

    2009-05-01

    Full Text Available Abstract Background The Locomotor Capabilities Index (LCI is a validated measure of lower-limb amputees' ability to perform activities with prosthesis. We have developed the LCI Swedish version and evaluated its validity and reliability. Methods Cross-cultural adaptation to Swedish included forward/backward translations and field testing. The Swedish LCI was then administered to 144 amputees (55 women, mean age 74 (40–93 years, attending post-rehabilitation prosthetic training. Construct validity was assessed by examining the relationship between the LCI and Timed "Up-and-Go" (TUG test and between the LCI and EQ-5D health utility index in 2 subgroups of 40 and 20 amputees, respectively. Discriminative validity was assessed by comparing scores in different age groups and in unilateral and bilateral amputees. Test-retest reliability (1–2 weeks was evaluated in 20 amputees (14 unilateral. Results The Swedish LCI showed good construct convergent validity, with high correlation with the TUG (r = -0.75 and the EQ-5D (r = 0.84, and discriminative validity, with significantly worse mean scores for older than younger and for bilateral than unilateral amputees (p Conclusion The Swedish version of the LCI demonstrated good validity and internal consistency in adult amputees. Test-retest reliability in a small subsample appears to be acceptable. The high ceiling effect of the LCI may imply that it would be most useful in assessing amputees with low to moderate functional abilities.

  8. The Danish Prostatic Symptom Score (DAN-PSS-1) questionnaire is reliable in stroke patients

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Jensen, Rigmor; Klarskov, Peter

    2006-01-01

    . The questionnaire consists of 12 questions related to lower urinary tract symptoms (LUTS). The participants were asked to state the frequency and severity of their symptoms (symptom score) and its impact on their daily life (bother score). Seventy-one stroke patients were included and 59 (83%) answered...... the questionnaire twice. The reliability test was done in two aspects: (a) detecting the frequency of each symptom and its bother factor, the scores were reduced to a two-category scale (=0, >0) and simple kappa statistics was used; (b) detecting the severity of each symptom and its bother factor, the total scale...... (kappa(w) = 0.48) to good (kappa(w) = 0.68). CONCLUSIONS: The DAN-PSS-1 questionnaire had acceptable test-retest reliability and may be suitable for measuring the frequency and severity of LUTS and its bother factor in stroke patients....

  9. [Reliability of the PRISCUS-PAQ. Questionnaire to assess physical activity of persons aged 70 years and older].

    Science.gov (United States)

    Trampisch, U; Platen, P; Burghaus, I; Moschny, A; Wilm, S; Thiem, U; Hinrichs, T

    2010-12-01

    A questionnaire (Q) to measure physical activity (PA) of persons ≥70 years for epidemiological research is lacking. The aim was to develop the PRISCUS-PAQ and test the reliability in community-dwelling people (≥70 years). Validated PA questionnaires were translated and adapted to design the PRISCUS-PAQ. Its test-retest reliability for 91 randomly selected people (36% men) aged 70-98 (76±5) years ranged from 0.47 (walking) to 0.82 (riding a bicycle). The overall activity score was 0.59 as determined by the intraclass correlation coefficient (ICC). Recording of general activities, e.g., housework (ICC=0.59), was in general less reliable than athletic activities, e.g., gymnastics (ICC=0.76). The PRISCUS-PAQ, which is a short instrument with acceptable reliability to collect the physical activity of the elderly in a telephone interview, will be used to collect data in a large cohort of older people in the German research consortium PRISCUS.

  10. Adaptation and Assessment of Reliability and Validity of the Greek Version of the Ohkuma Questionnaire for Dysphagia Screening

    Science.gov (United States)

    Papadopoulou, Soultana L.; Exarchakos, Georgios; Christodoulou, Dimitrios; Theodorou, Stavroula; Beris, Alexandre; Ploumis, Avraam

    2016-01-01

    Introduction The Ohkuma questionnaire is a validated screening tool originally used to detect dysphagia among patients hospitalized in Japanese nursing facilities. Objective The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the Ohkuma questionnaire. Methods Following the steps for cross-cultural adaptation, we delivered the validated Ohkuma questionnaire to 70 patients (53 men, 17 women) who were either suffering from dysphagia or not. All of them completed the questionnaire a second time within a month. For all of them, we performed a bedside and VFSS study of dysphagia and asked participants to undergo a second VFSS screening, with the exception of nine individuals. Statistical analysis included measurement of internal consistency with Cronbach's α coefficient, reliability with Cohen's Kappa, Pearson's correlation coefficient and construct validity with categorical components, and One-Way Anova test. Results According to Cronbach's α coefficient (0.976) for total score, there was high internal consistency for the Ohkuma Dysphagia questionnaire. Test-retest reliability (Cohen's Kappa) ranged from 0.586 to 1.00, exhibiting acceptable stability. We also estimated the Pearson's correlation coefficient for the test-retest total score, which reached high levels (0.952; p = 0.000). The One-Way Anova test in the two measurement times showed statistically significant correlation in both measurements (p = 0.02 and p = 0.016). Conclusion The adapted Greek version of the questionnaire is valid and reliable and can be used for the screening of dysphagia in the Greek-speaking patients. PMID:28050209

  11. Reliability, validity and sensitivity to change of neurogenic bowel dysfunction score in patients with spinal cord injury

    DEFF Research Database (Denmark)

    Erdem, D.; Hava, D.; Keskinoglu, P.

    2017-01-01

    cord injury (SCI). The reliability of NBD score was assessed by test-retest reliability and internal consistency. Cronbach's alpha coefficient was calculated to determine internal consistency. The construct validity was evaluated by exploring correlations between the NBD score and SF-36 scales, patient...... assessment of impact of NBD on quality of life (QoL) and the physician global assessment (PGA). The Global Rating of Change (GRC) scale was used to assess the change of NBD to investigate the sensitivity of the score to change. Results: Cronbach's alpha coefficient was 0.547. In test-retest reliability...

  12. Cross-cultural adaptation, content validation, and reliability of the Nigerian Composite Lifestyle CVD Risk Factors Questionnaire for adolescents among Yoruba rural adolescents in Nigeria.

    Science.gov (United States)

    Odunaiya, Nse A; Louw, Quinette A; Grimmer, Karen

    2017-06-01

    Assessment of lifestyle risk factors must be culturally- and contextually relevant and available in local languages. This paper reports on a study which aimed to cross culturally adapt a composite lifestyle cardiovascular disease (CVD) risk factors questionnaire into an African language (Yoruba) and testing some of its psychometric properties such as content validity and test retest reliability in comparison to the original English version. This study utilized a cross sectional design. Translation of the English version of the questionnaire into Yoruba was undertaken using the guideline by Beaton et al. The translated instrument was presented to 21 rural adolescents to assess comprehensibility and clarity using a sample of convenience. A test retest reliability was conducted among 150 rural adolescents using a purposive sampling. Data was analyzed using intraclass correlation (ICC ) model 3, Cohen kappa statistics and prevalence rates. ICC ranged between 0.4-0.8. The Yoruba version was completed 15-20 minutes and was reported to be culturally appropriate and acceptable for rural Nigerian adolescents. The Yoruba translation of the Nigerian composite lifestyle risk factors questionnaire performs at least as well as the original English version in terms of content validity and reliability. It took a shorter time to complete therefore may be more relevant to rural adolescents.

  13. Graph Theoretical Analysis of Functional Brain Networks: Test-Retest Evaluation on Short- and Long-Term Resting-State Functional MRI Data

    Science.gov (United States)

    Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong

    2011-01-01

    Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285

  14. Reliability of perceived neighbourhood conditions and the effects of measurement error on self-rated health across urban and rural neighbourhoods.

    Science.gov (United States)

    Pruitt, Sandi L; Jeffe, Donna B; Yan, Yan; Schootman, Mario

    2012-04-01

    Limited psychometric research has examined the reliability of self-reported measures of neighbourhood conditions, the effect of measurement error on associations between neighbourhood conditions and health, and potential differences in the reliabilities between neighbourhood strata (urban vs rural and low vs high poverty). We assessed overall and stratified reliability of self-reported perceived neighbourhood conditions using five scales (social and physical disorder, social control, social cohesion, fear) and four single items (multidimensional neighbouring). We also assessed measurement error-corrected associations of these conditions with self-rated health. Using random-digit dialling, 367 women without breast cancer (matched controls from a larger study) were interviewed twice, 2-3 weeks apart. Test-retest (intraclass correlation coefficients (ICC)/weighted κ) and internal consistency reliability (Cronbach's α) were assessed. Differences in reliability across neighbourhood strata were tested using bootstrap methods. Regression calibration corrected estimates for measurement error. All measures demonstrated satisfactory internal consistency (α ≥ 0.70) and either moderate (ICC/κ=0.41-0.60) or substantial (ICC/κ=0.61-0.80) test-retest reliability in the full sample. Internal consistency did not differ by neighbourhood strata. Test-retest reliability was significantly lower among rural (vs urban) residents for two scales (social control, physical disorder) and two multidimensional neighbouring items; test-retest reliability was higher for physical disorder and lower for one multidimensional neighbouring item among the high (vs low) poverty strata. After measurement error correction, the magnitude of associations between neighbourhood conditions and self-rated health were larger, particularly in the rural population. Research is needed to develop and test reliable measures of perceived neighbourhood conditions relevant to the health of rural populations.

  15. Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed.

    Science.gov (United States)

    Fokkema, Tryntsje; Kooiman, Thea J M; Krijnen, Wim P; VAN DER Schans, Cees P; DE Groot, Martijn

    2017-04-01

    To examine the test-retest reliability and validity of ten activity trackers for step counting at three different walking speeds. Thirty-one healthy participants walked twice on a treadmill for 30 min while wearing 10 activity trackers (Polar Loop, Garmin Vivosmart, Fitbit Charge HR, Apple Watch Sport, Pebble Smartwatch, Samsung Gear S, Misfit Flash, Jawbone Up Move, Flyfit, and Moves). Participants walked three walking speeds for 10 min each; slow (3.2 km·h), average (4.8 km·h), and vigorous (6.4 km·h). To measure test-retest reliability, intraclass correlations (ICC) were determined between the first and second treadmill test. Validity was determined by comparing the trackers with the gold standard (hand counting), using mean differences, mean absolute percentage errors, and ICC. Statistical differences were calculated by paired-sample t tests, Wilcoxon signed-rank tests, and by constructing Bland-Altman plots. Test-retest reliability varied with ICC ranging from -0.02 to 0.97. Validity varied between trackers and different walking speeds with mean differences between the gold standard and activity trackers ranging from 0.0 to 26.4%. Most trackers showed relatively low ICC and broad limits of agreement of the Bland-Altman plots at the different speeds. For the slow walking speed, the Garmin Vivosmart and Fitbit Charge HR showed the most accurate results. The Garmin Vivosmart and Apple Watch Sport demonstrated the best accuracy at an average walking speed. For vigorous walking, the Apple Watch Sport, Pebble Smartwatch, and Samsung Gear S exhibited the most accurate results. Test-retest reliability and validity of activity trackers depends on walking speed. In general, consumer activity trackers perform better at an average and vigorous walking speed than at a slower walking speed.

  16. Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarthritis.

    Science.gov (United States)

    Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip

    2018-06-01

    The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Lower limb spasticity assessment using an inertial sensor: a reliability study

    International Nuclear Information System (INIS)

    Sterpi, I; Colombo, R; Caroli, A; Meazza, E; Maggioni, G; Pistarini, C

    2013-01-01

    Spasticity is a common motor impairment in patients with neurological disorders that can prevent functional recovery after rehabilitation. In the clinical setting, its assessment is carried out using standardized clinical scales. The aim of this study was to verify the applicability of inertial sensors for an objective measurement of quadriceps spasticity and evaluate its test–retest and inter-rater reliability during the implementation of the Wartenberg pendulum test. Ten healthy subjects and 11 patients in vegetative state with severe brain damage were enrolled in this study. Subjects were evaluated three times on three consecutive days. The test–retest reliability of measurement was assessed in the first two days. The third day was devoted to inter-rater reliability assessment. In addition, the lower limb muscle tone was bilaterally evaluated at the knee joint by the modified Ashworth scale. The factorial ANOVA analysis showed that the implemented method allowed us to discriminate between healthy and pathological conditions. The fairly low SEM and high ICC values obtained for the pendulum parameters indicated a good test–retest and inter-rater reliability of measurement. This study shows that an inertial sensor can be reliably used to characterize leg kinematics during the Wartenberg pendulum test and provide quantitative evaluation of quadriceps spasticity. (paper)

  18. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    Science.gov (United States)

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  19. A study of the reliability of the Nociception Coma Scale.

    Science.gov (United States)

    Riganello, F; Cortese, M D; Arcuri, F; Candelieri, A; Guglielmino, F; Dolce, G; Sannita, W G; Schnakers, C

    2015-04-01

    In this study, we investigated the reliability of the Nociception Coma Scale which has recently been developed to assess nociception in non-communicative, severely brain-injured patients. Prospective cross-sequential study. Semi-intensive care unit and long-term brain injury care. Forty-four patients diagnosed as being in a vegetative state (n=26) or in a minimally conscious state (n=18). Patients were assessed by two experts (rater A and rater B) on two consecutive weeks to measure inter-rater agreement and test-retest reliability. Total scores and subscores of the Nociception Coma Scale. We performed a total of 176 assessments. The inter-rater agreement was moderate for the total scores (k = 0.57) and fair to substantial for the subscores (0.33 ≤ k ≤ 0.62) on week 2. The test-retest reliability was substantial for the total scores (k = 0.66) and moderate to almost perfect for the subscores (0.53 ≤ k ≤ 0.96) for rater A. The inter-rater agreement was weaker on week 1, whereas the test-retest reliability was lower for the least experienced rater (rater B). This study provides further evidence of the psychometric qualities of the Nociception Coma Scale. Future studies should assess the impact of practical experience and background on administration and scoring of the scale. © The Author(s) 2014.

  20. Reliability of sonographic assessment of tendinopathy in tennis elbow.

    Science.gov (United States)

    Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim

    2012-01-01

    To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.

  1. Test-retest reproducibility of dopamine D{sub 2/3} receptor binding in human brain measured by PET with [{sup 11}C]MNPA and [{sup 11}C]raclopride

    Energy Technology Data Exchange (ETDEWEB)

    Kodaka, Fumitoshi [National Institute of Radiological Sciences, Molecular Neuroimaging Program, Molecular Imaging Center, Chiba (Japan); Jikei University School of Medicine, Department of Psychiatry, Tokyo (Japan); Ito, Hiroshi [National Institute of Radiological Sciences, Molecular Neuroimaging Program, Molecular Imaging Center, Chiba (Japan); National Institute of Radiological Sciences, Biophysics Program, Molecular Imaging Center, Chiba (Japan); Kimura, Yasuyuki; Fujie, Saori; Takano, Harumasa; Fujiwara, Hironobu; Sasaki, Takeshi; Suhara, Tetsuya [National Institute of Radiological Sciences, Molecular Neuroimaging Program, Molecular Imaging Center, Chiba (Japan); Nakayama, Kazuhiko [Jikei University School of Medicine, Department of Psychiatry, Tokyo (Japan); Halldin, Christer; Farde, Lars [Karolinska Institutet, Department of Clinical Neuroscience, Stockholm (Sweden)

    2013-04-15

    Dopamine D{sub 2/3} receptors (D{sub 2/3}Rs) have two affinity states for endogenous dopamine, referred to as high-affinity state (D{sub 2/3} {sup HIGH}), which has a high affinity for endogenous dopamine, and low-affinity state (D{sub 2/3} {sup LOW}). The density of D{sub 2/3} {sup HIGH} can be measured with (R)-2-{sup 11}CH{sub 3}O-N-n-propylnorapomorphine ([{sup 11}C]MNPA), while total density of D{sub 2/3} {sup HIGH} and D{sub 2/3} {sup LOW} (D{sub 2/3}Rs) can be measured with [{sup 11}C]raclopride using positron emission tomography (PET). Thus, the ratio of the binding potential (BP) of [{sup 11}C]MNPA to that of [{sup 11}C]raclopride ([{sup 11}C]MNPA/[{sup 11}C]raclopride) may reflect the proportion of the density of D{sub 2/3} {sup HIGH} to that of D{sub 2/3}Rs. In the caudate and putamen, [{sup 11}C]MNPA/[{sup 11}C]raclopride reflects the proportion of the density of D{sub 2} {sup HIGH} to that of D{sub 2}Rs. To evaluate the reliability of the PET paradigm with [{sup 11}C]MNPA and [{sup 11}C]raclopride, we investigated the test-retest reproducibility of non-displaceable BP (BP{sub ND}) measured with [{sup 11}C]MNPA and of [{sup 11}C]MNPA/[{sup 11}C]raclopride in healthy humans. Eleven healthy male volunteers underwent two sets of PET studies on separate days that each included [{sup 11}C]MNPA and [{sup 11}C]raclopride scans. BP{sub ND} values in the caudate and putamen were calculated. Test-retest reproducibility of BP{sub ND} of [{sup 11}C]MNPA and [{sup 11}C]MNPA/[{sup 11}C]raclopride was assessed by intra-subject variability (absolute variability) and test-retest reliability (intraclass correlation coefficient: ICC). The absolute variability of [{sup 11}C]MNPA BP{sub ND} was 5.30 {+-} 3.96 % and 12.3 {+-} 7.95 % and the ICC values of [{sup 11}C]MNPA BP{sub ND} were 0.72 and 0.82 in the caudate and putamen, respectively. The absolute variability of [{sup 11}C]MNPA/[{sup 11}C]raclopride was 6.11 {+-} 3.68 % and 11.60 {+-} 5.70 % and the ICC values of [{sup

  2. Examination of the reliability and validity of the Mindful Eating Questionnaire in pregnant women.

    Science.gov (United States)

    Apolzan, John W; Myers, Candice A; Cowley, Amanda D; Brady, Heather; Hsia, Daniel S; Stewart, Tiffany M; Redman, Leanne M; Martin, Corby K

    2016-05-01

    Mindfulness is theorized to affect the eating behavior and weight of pregnant women, yet no measure has been validated during pregnancy. This study qualitatively and quantitatively evaluated the reliability and validity of the Mindful Eating Questionnaire (MEQ) in overweight and obese pregnant women. Participants completed focus groups and cognitive interviews. The MEQ was administered twice to measure test-retest reliability. The Eating Inventory (EI) and Mindful Attention Awareness Scale (MAAS) were administered to assess convergent validity, and the Neighborhood Environment Walkability Scale (NEWS) assessed discriminant validity. Participants were 20 ± 8 weeks gestation (mean ± SD), 30 ± 2 years old, and 55% were obese. The MEQ total score had good test-retest reliability (r = .85). The total score internal consistency reliability was poor (Cronbach's α = .56). The external cues subscale (ECS) was not internally consistent (α = .31). Other subscales ranged from α = .59-.68. When the ECS was excluded, the MEQ total score internal consistency was acceptable (α = .62). Convergent validity was supported by the MEQ total score (with and without ECS) correlating significantly with the MAAS and the EI disinhibition and hunger subscales. Discriminant validity of the MEQ was supported by the MEQ and NEWS total scores and subscales not being significantly correlated. The quantitative results were supported by the qualitative context and content analysis. With the exception of the ECS, the MEQ's reliability and validity was supported in pregnant women, and most of the subscales were more robust in pregnant women than in the original sample of healthy adults. The MEQ's use with overweight and obese pregnant women is supported. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Cross-cultural validation and psychometric testing of the Norwegian version of the TeamSTEPPS® teamwork perceptions questionnaire.

    Science.gov (United States)

    Ballangrud, Randi; Husebø, Sissel Eikeland; Hall-Lord, Marie Louise

    2017-12-02

    Teamwork is an integrated part of today's specialized and complex healthcare and essential to patient safety, and is considered as a core competency to improve twenty-first century healthcare. Teamwork measurements and evaluations show promising results to promote good team performance, and are recommended for identifying areas for improvement. The validated TeamSTEPPS® Teamwork Perception Questionnaire (T-TPQ) was found suitable for cross-cultural validation and testing in a Norwegian context. T-TPQ is a self-report survey that examines five dimensions of perception of teamwork within healthcare settings. The aim of the study was to translate and cross-validate the T-TPQ into Norwegian, and test the questionnaire for psychometric properties among healthcare personnel. The T-TPQ was translated and adapted to a Norwegian context according to a model of a back-translation process. A total of 247 healthcare personnel representing different professionals and hospital settings responded to the questionnaire. A confirmatory factor analysis was carried out to test the factor structure. Cronbach's alpha was used to establish internal consistency, and an Intraclass Correlation Coefficient was used to assess the test - retest reliability. A confirmatory factor analysis showed an acceptable fitting model (χ 2 (df) 969.46 (546), p teamwork dimension clearly represents that specific construct. The Cronbach's alpha demonstrated acceptable values on the five subscales (0.786-0.844), and test-retest showed a reliability parameter, with Intraclass Correlation Coefficient scores from 0.672 to 0.852. The Norwegian version of T-TPQ was considered to be acceptable regarding the validity and reliability for measuring Norwegian individual healthcare personnel's perception of group level teamwork within their unit. However, it needs to be further tested, preferably in a larger sample and in different clinical settings.

  4. Clinimetric quality of the fire fighting simulation test as part of the Dutch fire fighters Workers' Health Surveillance

    Directory of Open Access Journals (Sweden)

    Sluiter Judith K

    2010-02-01

    Full Text Available Abstract Background Clinimetric data for the fire fighting simulation test (FFST, a new test proposed for the Workers' Health Surveillance (WHS of Dutch fire fighters, were evaluated. Methods Twenty-one fire fighters took the FFST three times with one and three weeks between testing. Clinimetric quality was determined by means of reliability, agreement and validity. For reliability and agreement, the intraclass correlation coefficient (ICC, and standard error of measurement (SEM, were analysed. For construct validity, the tests from 45 fire fighters were correlated with their own and their supervisors' rated work ability. Results The ICCs were 0.56 and 0.79 at the one-week and three-week test-retest periods, respectively. Testing times ranged from 9 to 17 minutes; the SEMs were 70 s at the one-week and 40 s at the three-week test-retest periods. The construct validity was moderate (-0.47 ≤ r ≤ -0.33; p Conclusions The FFST was reliable with acceptable agreement after three weeks. Construct validity was moderate. We recommend using FFST as a part of the WHS for Dutch fire fighters. It is advised that fire fighters should perform the FFST once as a trial before judging their performance in testing time during the second performance.

  5. Reliability and validity of the Physical Activity Scale for the Elderly (PASE in patients with hip osteoarthritis

    Directory of Open Access Journals (Sweden)

    Svege Ida

    2012-02-01

    Full Text Available Abstract Background Physical activity (PA is beneficial in reducing pain and improving function in lower limb osteoarthritis (OA, and is recommended as a first line treatment. Self-administered questionnaires are used to assess PA, but knowledge about reliability and validity of these PA questionnaires are limited, in particular for patients with OA. The purpose of this study was to evaluate the reliability and validity of the Physical Activity Scale for the Elderly (PASE in patients with hip OA. Methods Forty patients with hip OA (20 men and 20 women, mean age 61.3 ± 10 years were included. For test-retest reliability PASE was administered twice with a mean time between tests of 9 ± 4 days. Intraclass correlation coefficient (ICC, standard error of measurement (SEM and minimal detectable change (MDC were calculated for the total score and for the particular items assessing different PA intensity levels. In addition a Bland-Altman analysis for the total PASE score was performed. Construct validity was evaluated by comparing the PASE results with the Actigraph GT1M accelerometer and the International Physical Activity Questionnaire (IPAQ, using the Spearman rank correlation coefficient. Results ICC for the total PASE score was 0.78, with relatively large error of measurement; SEM = 31 and MDC = 87. ICC for the intensity items was 0.20 for moderate PA intensity, 0.46 for light PA intensity and to 0.68 for vigorous PA intensity. The Spearman rank correlation coefficient between the Actigraph GT1M total counts per minute and the total PASE score was 0.30 (p = 0.089, and ranging from 0.20-0.38 for the different PA intensity categories. The Spearman rank correlation between IPAQ and PASE was 0.61 (p = 0.001 for the total scores. Conclusions In patients with hip OA the test-retest reliability of the total PASE score was moderate, with acceptable ICC, but with large measurement errors. The construct validity of the PASE was poor when compared to the

  6. Can health workers reliably assess their own work? A test-retest study of bias among data collectors conducting a Lot Quality Assurance Sampling survey in Uganda.

    Science.gov (United States)

    Beckworth, Colin A; Davis, Rosemary H; Faragher, Brian; Valadez, Joseph J

    2015-03-01

    Lot Quality Assurance Sampling (LQAS) is a classification method that enables local health staff to assess health programmes for which they are responsible. While LQAS has been favourably reviewed by the World Bank and World Health Organization (WHO), questions remain about whether using local health staff as data collectors can lead to biased data. In this test-retest research, Pallisa Health District in Uganda is subdivided into four administrative units called supervision areas (SA). Data collectors from each SA conducted an LQAS survey. A week later, the data collectors were swapped to a different SA, outside their area of responsibility, to repeat the LQAS survey with the same respondents. The two data sets were analysed for agreement using Cohens' kappa coefficient and disagreements were analysed. Kappa values ranged from 0.19 to 0.97. On average, there was a moderate degree of agreement for knowledge indicators and a substantial level for practice indicators. Respondents were found to be systematically more knowledgeable on retest indicating bias favouring the retest, although no evidence of bias was found for practices indicators. In this initial study, using local health care providers to collect data did not bias data collection. The bias observed in the knowledge indicators is most likely due to the 'practice effect', whereby respondents increased their knowledge as a result of completing the first survey, as no corresponding effect was seen in the practices indicators. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2014; all rights reserved.

  7. The relative and absolute reliability of the Functional Independence and Difficulty Scale in community-dwelling frail elderly Japanese people using long-term care insurance services.

    Science.gov (United States)

    Saito, Takashi; Izawa, Kazuhiro P; Watanabe, Shuichiro

    2017-06-01

    The newly developed Functional Independence and Difficulty Scale is a tool for assessing the performance of basic activities of daily living in terms of both independence and difficulty. The reliability of this new scale has not been assessed. The aim of this study was to examine the relative reliability and absolute reliability of the newly developed scale in community-dwelling frail elderly people in Japan. Participants were 47 community-dwelling elderly subjects (22 for assessing test-retest reliability and 25 for assessing inter-rater reliability). As relative reliability indices, intra-class correlation coefficients were used. From an absolute reliability perspective, we conducted Bland-Altman analysis and calculated the limit of agreement or minimal detectable change to determine the acceptable range of error. Intra-class correlation coefficients for test-retest and inter-rater reliability were 0.90 (P reliability was -5.2 to 1.8, representing an increase of over six points for improvement and a decrease of over two points for decline of basic activities of daily living ability. The minimal detectable change for inter-rater reliability was 3.7, indicating that a three-point difference might be existed between difference raters. The results of this study demonstrated that the FIDS appeared to be a reliable instrument for use in Japanese community-dwelling frail elderly people. While further research using a large and more diverse sample of participants is needed, our findings support the use of FIDS in clinical practice or clinical research targeting frail elderly Japanese people.

  8. Validity and reliability of a brief self-reported questionnaire assessing fruit and vegetable consumption among pregnant women

    Directory of Open Access Journals (Sweden)

    Lydi-Anne Vézina-Im

    2016-09-01

    Full Text Available Abstract Background Short instruments measuring frequency of specific foods, such as fruit and vegetable (FV, are increasingly used in interventions. The objective of the study was to verify the validity and test-retest reliability of such an instrument among pregnant women. Methods Pregnant women from the region of Quebec City, Quebec, Canada, were recruited through e-mails sent to female students and employees of the local university from October 2014 to April 2015. To assess the validity of the fruit and vegetable questionnaire (FVQ developed by Godin et al. (Can J Public Health 99: 494-498, 2008, pregnant women were asked in a first mailing to complete the FVQ assessing FV intake over the past 7 days and a 3-day estimated food record. A subsample (n = 33 also gave a fasting blood sample and completed a validated semi-quantitative FFQ administered by a trained registered dietitian during a visit at the research center. FV intakes for all instruments were calculated in terms of servings of FV based on Canada’s Food Guide definition of a serving of fruit or vegetable. In order to assess its test-retest reliability, respondents were asked to complete the FVQ 14 days later in a second mailing. Results Forty-eight pregnant women from all three trimesters completed the questionnaires in the first mailing. FV intake assessed using the FVQ was correlated to FV consumption measured using the food record (r = 0.34, p = 0.0180 and the FFQ (r = 0.61, p = 0.0002. Results were similar when controlling for energy intake and the experience of nausea in the past month. Only β-cryptoxanthin was significantly correlated to FV intake assessed by the FFQ when adjusted for the presence of nausea (r = 0.35, p = 0.0471. Data on the test-retest reliability was available for 44 women and the intra-class coefficient for the FVQ was 0.72 at a mean 28-day interval. Conclusions The FVQ has acceptable validity and test-retest reliability

  9. Validity and reliability of a brief self-reported questionnaire assessing fruit and vegetable consumption among pregnant women.

    Science.gov (United States)

    Vézina-Im, Lydi-Anne; Godin, Gaston; Couillard, Charles; Perron, Julie; Lemieux, Simone; Robitaille, Julie

    2016-09-15

    Short instruments measuring frequency of specific foods, such as fruit and vegetable (FV), are increasingly used in interventions. The objective of the study was to verify the validity and test-retest reliability of such an instrument among pregnant women. Pregnant women from the region of Quebec City, Quebec, Canada, were recruited through e-mails sent to female students and employees of the local university from October 2014 to April 2015. To assess the validity of the fruit and vegetable questionnaire (FVQ) developed by Godin et al. (Can J Public Health 99: 494-498, 2008), pregnant women were asked in a first mailing to complete the FVQ assessing FV intake over the past 7 days and a 3-day estimated food record. A subsample (n = 33) also gave a fasting blood sample and completed a validated semi-quantitative FFQ administered by a trained registered dietitian during a visit at the research center. FV intakes for all instruments were calculated in terms of servings of FV based on Canada's Food Guide definition of a serving of fruit or vegetable. In order to assess its test-retest reliability, respondents were asked to complete the FVQ 14 days later in a second mailing. Forty-eight pregnant women from all three trimesters completed the questionnaires in the first mailing. FV intake assessed using the FVQ was correlated to FV consumption measured using the food record (r = 0.34, p = 0.0180) and the FFQ (r = 0.61, p = 0.0002). Results were similar when controlling for energy intake and the experience of nausea in the past month. Only β-cryptoxanthin was significantly correlated to FV intake assessed by the FFQ when adjusted for the presence of nausea (r = 0.35, p = 0.0471). Data on the test-retest reliability was available for 44 women and the intra-class coefficient for the FVQ was 0.72 at a mean 28-day interval. The FVQ has acceptable validity and test-retest reliability values, but seems to underestimate FV servings in pregnant women

  10. The validity and reliability of the Functional Strength Measurement (FSM) in children with intellectual disabilities.

    Science.gov (United States)

    Aertssen, W F M; Steenbergen, B; Smits-Engelsman, B C M

    2018-06-07

    There is lack of valid and reliable field-based tests for assessing functional strength in young children with mild intellectual disabilities (IDs). The aim of this study was to investigate the test-retest reliability and construct validity of the Functional Strength Measurement in children with ID (FSM-ID). Fifty-two children with mild ID (40 boys and 12 girls, mean age 8.48 years, SD = 1.48) were tested with the FSM. Test-retest reliability (n = 32) was examined by a two-way interclass correlation coefficient for agreement (ICC 2.1A). Standard error of measurement and smallest detectable change were calculated. Construct validity was determined by calculating correlations between the FSM-ID and handheld dynamometry (HHD) (convergent validity), FSM-ID, FSM-ID and subtest strength of the Bruininks-Oseretsky test of motor proficiency - second edition (BOT-2) (convergent validity) and the FSM-ID and balance subtest of the BOT-2 (discriminant validity). Test-retest reliability ICC ranged 0.89-0.98. Correlation between the items of the FSM-ID and HHD ranged 0.39-0.79 and between FSM-ID and BOT-2 (strength items) 0.41-0.80. Correlation between items of the FSM-ID and BOT-2 (balance items) ranged 0.41-0.70. The FSM-ID showed good test-retest reliability and good convergent validity with the HHD and BOT-2 subtest strength. The correlations assessing discriminant validity were higher than expected. Poor levels of postural control and core stability in children with mild IDs may be the underlying factor of those higher correlations. © 2018 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  11. Validity and Reliability of the Clock Drawing Test in Older People

    Directory of Open Access Journals (Sweden)

    Massoumeh Sadeghipour Roodsari

    2013-07-01

    Full Text Available Objectives: Early diagnosis of cognitive disorders in order to initiate new efficient treatments in time is an important task which cannot be fulfilled without proper cognitive screening tools. The Clock Drawing Test (CDT is a simple inexpensive cognitive screening tool which can be used in primary care settings delivering health services to older people. The aim of this study was to assess validity and reliability of the CDT in Iranian older population. Methods & Materials: In this study the CDT and Mini Mental State Examination (MMSE were concurrently performed on 74 literate participants aged 60 and over. Participants were recruited from the clients of Iran Alzheimer’s Association (dementia patients and non-demented clients, including other patients or care givers during a 5 month period. The CDT was performed by two trained raters using Shulman’s six points scoring method. Using SPSS version 20, reliability was assessed measuring kappa statistics as well as ICC. Concurrent validity between CDT and MMSE were statistically analyzed by spearman’s rank correlation coefficient. Results: Mean age of the participants was 72 years in a range of 60 to 90 years with equal numbers 0f male and female participants. Kappa statistics for test retest reliability was 0.554 (P<0.001. ICC for inter rater reliability was 0.964 (P<0.001. Spearman’s rank correlation coefficient for MMSE and CDT scores was 0.782, statistically significant at P<0.001. Conclusion: CDT is a valid and reliable test in literate older people that can be used as a cognitive screening tool in Iranian older population.

  12. RELIABILITY OF THE ONE REPETITION-MAXIMUM POWER CLEAN TEST IN ADOLESCENT ATHLETES

    Science.gov (United States)

    Faigenbaum, Avery D.; McFarland, James E.; Herman, Robert; Naclerio, Fernando; Ratamess, Nicholas A.; Kang, Jie; Myer, Gregory D.

    2013-01-01

    Although the power clean test is routinely used to assess strength and power performance in adult athletes, the reliability of this measure in younger populations has not been examined. Therefore, the purpose of this study was to determine the reliability of the one repetition maximum (1 RM) power clean in adolescent athletes. Thirty-six male athletes (age 15.9 ± 1.1 yrs, body mass 79.1 ± 20.3 kg, height 175.1 ±7.4 cm) who had more than 1 year of training experience with weightlifting exercises performed a 1 RM power clean on two nonconsecutive days in the afternoon following standardized procedures. All test procedures were supervised by a senior level weightlifting coach and consisted of a systematic progression in test load until the maximum resistance that could be lifted for one repetition using proper exercise technique was determined. Data were analyzed using an intraclass correlation coefficient (ICC [2,k]), Pearson correlation coefficient (r), repeated measures ANOVA, Bland-Altman plot, and typical error analyses. Analysis of the data revealed that the test measures were highly reliable demonstrating a test-retest ICC of 0.98 (95% CI = 0.96–0.99). Testing also demonstrated a strong relationship between 1 RM measures on trial 1 and trial 2 (r=0.98, pinjuries occurred during the study period and the testing protocol was well-tolerated by all subjects. These findings indicate that 1 RM power clean testing has a high degree of reproducibility in trained male adolescent athletes when standardized testing procedures are followed and qualified instruction is present. PMID:22233786

  13. Reliability of the Discounting Inventory: An extension into substance-use population

    Directory of Open Access Journals (Sweden)

    Malesza Marta

    2017-06-01

    Full Text Available Recent research introduced the Discounting Inventory that allows the measurement of individual differences in the delay, probabilistic, effort, and social discounting rates. The goal of this investigation was to determine several aspects of the reliability of the Discounting Inventory using the responses of 385 participants (200 non-smokers and 185 current-smokers. Two types of reliability are of interest. Internal consistency and test-retest stability. A secondary aim was to extend such reliability measures beyond the non-clinical participant. The current study aimed to measure the reliability of the DI in a nicotine-dependent individuals and non-nicotine-dependent individuals. It is concluded that the internal consistency of the DI is excellent, and that the test-retest reliability results suggest that items intended to measure three types of discounting were likely testing trait, rather than state, factors, regardless of whether “non-smokers” were included in, or excluded from, the analyses (probabilistic discounting scale scores being the exception. With these cautions in mind, however, the psychometric properties of the DI appear to be very good.

  14. Fiabilidad del test 6 minutos caminando en personas con secuelas de poliomielitis paralítica mediante test-retest de 12 semanas

    Directory of Open Access Journals (Sweden)

    Francisco Javier Domínguez-Muñoz

    2013-01-01

    Full Text Available El análisis de la fiabilidad del test de 6 minutos ca- minando en una población de personas con secuelas de poliomielitis paralítica mediante test-retest de 12 semanas no ha sido estudiado. Participaron personas con secuelas de poliomielitis paralítica (n = 18; 48,72 ± 7,69 años; 65,8 ± 11,6 kg. Se les realizó un test-retest de 12 semanas de la prueba de 6 minutos caminando que consistía en que los sujetos anduvieran la mayor distan- cia, sin llegar a la carrera, en un periodo de 6 minutos. La fiabilidad relativa de la prueba fue excelente (CCI = 0,99. En lo que se refiere a la fiabilidad absoluta se obtuvo un error estándar de medida (SEM del 1,7% y un mínimo cambio real (SRD de 4,7%. La fiabilidad del test de 6 minutos caminando usando el método Bland- Altman mostró que el error sistemático (diferencia de medias entre el test-retest fue 2,72 (bias. En conclu- sión, los resultados obtenidos en el test de 6 minutos ca- minando han sido muy fiables y afirmamos que la prue- ba de 6 minutos caminando podrá ser utilizada como prueba de evaluación en una población con secuelas de poliomielitis paralítica, con un intervalo de 12 semanas entre las dos mediciones, para comprobar los cambios que se han producido tras la aplicación de un programa de actividad física.

  15. Validity and reliability of the Bahasa Melayu version of the Migraine Disability Assessment questionnaire.

    Science.gov (United States)

    Shaik, Munvar Miya; Hassan, Norul Badriah; Tan, Huay Lin; Bhaskar, Shalini; Gan, Siew Hua

    2014-01-01

    The study was designed to determine the validity and reliability of the Bahasa Melayu version (MIDAS-M) of the Migraine Disability Assessment (MIDAS) questionnaire. Patients having migraine for more than six months attending the Neurology Clinic, Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia, were recruited. Standard forward and back translation procedures were used to translate and adapt the MIDAS questionnaire to produce the Bahasa Melayu version. The translated Malay version was tested for face and content validity. Validity and reliability testing were further conducted with 100 migraine patients (1st administration) followed by a retesting session 21 days later (2nd administration). A total of 100 patients between 15 and 60 years of age were recruited. The majority of the patients were single (66%) and students (46%). Cronbach's alpha values were 0.84 (1st administration) and 0.80 (2nd administration). The test-retest reliability for the total MIDAS score was 0.73, indicating that the MIDAS-M questionnaire is stable; for the five disability questions, the test-retest values ranged from 0.77 to 0.87. The MIDAS-M questionnaire is comparable with the original English version in terms of validity and reliability and may be used for the assessment of migraine in clinical settings.

  16. Reliability and Repetition Effect of the Center of Pressure and Kinematics Parameters That Characterize Trunk Postural Control During Unstable Sitting Test.

    Science.gov (United States)

    Barbado, David; Moreside, Janice; Vera-Garcia, Francisco J

    2017-03-01

    Although unstable seat methodology has been used to assess trunk postural control, the reliability of the variables that characterize it remains unclear. To analyze reliability and learning effect of center of pressure (COP) and kinematic parameters that characterize trunk postural control performance in unstable seating. The relationships between kinematic and COP parameters also were explored. Test-retest reliability design. Biomechanics laboratory setting. Twenty-three healthy male subjects. Participants volunteered to perform 3 sessions at 1-week intervals, each consisting of five 70-second balancing trials. A force platform and a motion capture system were used to measure COP and pelvis, thorax, and spine displacements. Reliability was assessed through standard error of measurement (SEM) and intraclass correlation coefficients (ICC 2,1 ) using 3 methods: (1) comparing the last trial score of each day; (2) comparing the best trial score of each day; and (3) calculating the average of the three last trial scores of each day. Standard deviation and mean velocity were calculated to assess balance performance. Although analyses of variance showed some differences in balance performance between days, these differences were not significant between days 2 and 3. Best result and average methods showed the greatest reliability. Mean velocity of the COP showed high reliability (0.71 reliability (0.37 reliability using the average method (0.62 reliability than kinematics ones. Specifically, mean velocity of COP showed the highest test-retest reliability, especially for the average and best methods. Although correlations between COP and mean joint angular velocity were high, the few relationships between COP and kinematic standard deviation suggest different postural behavior can lead to a similar balance performance during an unstable sitting protocol. III. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights

  17. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults.

    Science.gov (United States)

    Piper, Brian J; Mueller, Shane T; Geerken, Alexander R; Dixon, Kyle L; Kroliczak, Gregory; Olsen, Reid H J; Miller, Jeremy K

    2015-01-01

    Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18-22). Study II evaluated test-retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18-22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen's d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance.

  18. Dementia caregiver burden: reliability of the Brazilian version of the Zarit caregiver burden interview

    Directory of Open Access Journals (Sweden)

    Taub Anita

    2004-01-01

    Full Text Available The object of this article is to examine the reliability of the Brazilian version of the Zarit Caregiver Burden Interview (ZBI. The instrument is a 22-item scale assessing the extent to which caregivers view their responsibilities as having an adverse impact on their social life, health, emotional well-being, and finances. We assessed 50 primary informal caregivers of demented patients coming from 3 different health care centers, using the test-retest method. Analysis of the results showed an intraclass reliability coefficient of 0.88, while Cronbach's coefficient alpha was 0.77 for the test and 0.80 for the retest items. The Brazilian version of ZBI shows sufficient reliability, comparable to the original version.

  19. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults

    Directory of Open Access Journals (Sweden)

    Brian J. Piper

    2015-12-01

    Full Text Available Background. The Psychology Experiment Building Language (PEBL software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures.Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity, attention (Test of Attentional Vigilance and Time-Wall, working memory (Digit Span Forward, and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation in a normative sample (N = 189, ages 18–22. Study II evaluated test–retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18–22.Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen’s d = 0.89 and Mental Rotation (d = 0.31 tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86 and attention (Test of Attentional Vigilance response time r = .79, intermediate for memory (digit span r = .63 but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15. Significant practice effects were identified on several indices of executive function.Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net is a versatile research tool to study individual differences in neurocognitive performance.

  20. The reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a German general practice population sample.

    Science.gov (United States)

    Dybek, Inga; Bischof, Gallus; Grothues, Janina; Reinhardt, Susa; Meyer, Christian; Hapke, Ulfert; John, Ulrich; Broocks, Andreas; Hohagen, Fritz; Rumpf, Hans-Jürgen

    2006-05-01

    Our goal was to analyze the retest reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a primary-care setting and recommend a cut-off value for the different alcohol-related diagnoses. Participants recruited from general practices (GPs) in two northern German cities received the AUDIT, which was embedded in a health-risk questionnaire. In total, 10,803 screenings were conducted. The retest reliability was tested on a subsample of 99 patients, with an intertest interval of 30 days. Sensitivity and specificity at a number of different cut-off values were estimated for the sample of alcohol consumers (n=8237). For this study, 1109 screen-positive patients received a diagnostic interview. Individuals who scored less than five points in the AUDIT and also tested negative in a second alcohol-related screen were defined as "negative" (n=6003). This definition was supported by diagnostic interviews of 99 screen-negative patients from which no false negatives could be detected. As the gold standard for detection of an alcohol-use disorder (AUD), we used the Munich-Composite International Diagnostic Interview (MCIDI), which is based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria. On the item level, the reliability, measured by the intraclass correlation coefficient (ICC), ranged between .39 (Item 9) and .98 (Item 10). For the total score, the ICC was .95. For cut-off values of eight points and five points, 87.5% and 88.9%, respectively, of the AUDIT-positives, and 98.9% and 95.1%, respectively, of the AUDIT-negatives were identically identified at retest, with kappa = .86 and kappa = .81. At the cut-off value of five points, we determined good combinations of sensitivity and specificity for the following diagnoses: alcohol dependence (sensitivity and specificity of .97 and .88, respectively), AUD (.97 and .92), and AUD and/or at-risk consumption (.97 and .91). Embedded in a health-risk questionnaire in

  1. Development, initial content validation and reliability of Nigerian ...

    African Journals Online (AJOL)

    Prevention strategies are effective only when there are epidemiological data for the targeted populations. The collection of such .... Proquest, Sport discuss and Cochrane as these are ... 0.74, test retest reliability 0.70; Diet: internal consistency:.

  2. Reliability Correction for Functional Connectivity: Theory and Implementation

    Science.gov (United States)

    Mueller, Sophia; Wang, Danhong; Fox, Michael D.; Pan, Ruiqi; Lu, Jie; Li, Kuncheng; Sun, Wei; Buckner, Randy L.; Liu, Hesheng

    2016-01-01

    Network properties can be estimated using functional connectivity MRI (fcMRI). However, regional variation of the fMRI signal causes systematic biases in network estimates including correlation attenuation in regions of low measurement reliability. Here we computed the spatial distribution of fcMRI reliability using longitudinal fcMRI datasets and demonstrated how pre-estimated reliability maps can correct for correlation attenuation. As a test case of reliability-based attenuation correction we estimated properties of the default network, where reliability was significantly lower than average in the medial temporal lobe and higher in the posterior medial cortex, heterogeneity that impacts estimation of the network. Accounting for this bias using attenuation correction revealed that the medial temporal lobe’s contribution to the default network is typically underestimated. To render this approach useful to a greater number of datasets, we demonstrate that test-retest reliability maps derived from repeated runs within a single scanning session can be used as a surrogate for multi-session reliability mapping. Using data segments with different scan lengths between 1 and 30 min, we found that test-retest reliability of connectivity estimates increases with scan length while the spatial distribution of reliability is relatively stable even at short scan lengths. Finally, analyses of tertiary data revealed that reliability distribution is influenced by age, neuropsychiatric status and scanner type, suggesting that reliability correction may be especially important when studying between-group differences. Collectively, these results illustrate that reliability-based attenuation correction is an easily implemented strategy that mitigates certain features of fMRI signal nonuniformity. PMID:26493163

  3. Reliability of fitness tests using methods and time periods common in sport and occupational management.

    Science.gov (United States)

    Burnstein, Bryan D; Steele, Russell J; Shrier, Ian

    2011-01-01

    Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.

  4. Polish Adult Reading Test (PART) - construction of Polish test for estimating the level of premorbid intelligence in schizophrenia.

    Science.gov (United States)

    Karakuła-Juchnowicz, Hanna; Stecka, Mariola

    2017-08-29

    In view of unavailability in Poland of the standardized methods to measure PIQ, the aim of the work was to develop a Polish test to assess the premorbid level of intelligence - PART(Polish AdultReading Test) and to measureits psychometric properties, such as validity, reliability as well as standardization in the group of schizophrenia patients. The principles of PART construction were based on the idea of popular worldwide National Adult Reading Test by Hazel Nelson. The research comprised a group of 122 subjects (65 schizophrenia patients and 57 healthy people), aged 18-60 years, matched for age and gender. PART appears to be a method with high internal consistency and reliability measured by test-retest, inter-rater reliability, and the method with acceptable diagnostic and prognostic validity. The standardized procedures of PART have been investigated and described. Considering the psychometric values of PART and a short time of its performance, the test may be a useful diagnostic instrument in the assessment of premorbid level of intelligence in a group of schizophrenic patients.

  5. Development and psychometric testing of a trans-professional evidence-based practice profile questionnaire.

    Science.gov (United States)

    McEvoy, Maureen Patricia; Williams, Marie T; Olds, Timothy Stephen

    2010-01-01

    Previous survey tools operationalising knowledge, attitudes or beliefs about evidence-based practice (EBP) have shortcomings in content, psychometric properties and target audience. This study developed and psychometrically assessed a self-report trans-professional questionnaire to describe an EBP profile. Sixty-six items were collated from existing EBP questionnaires and administered to 526 academics and students from health and non-health backgrounds. Principal component factor analysis revealed the presence of five factors (Relevance, Terminology, Confidence, Practice and Sympathy). Following expert panel review and pilot testing, the 58-item final questionnaire was disseminated to 105 subjects on two occasions. Test-retest and internal reliability were quantified using intra-class correlation coefficients (ICCs) and Cronbach's alpha, convergent validity against a commonly used EBP questionnaire by Pearson's correlation coefficient and discriminative validity via analysis of variance (ANOVA) based on exposure to EBP training. The final questionnaire demonstrated acceptable internal consistency (Cronbach's alpha 0.96), test-retest reliability (ICCs range 0.77-0.94) and convergent validity (Practice 0.66, Confidence 0.80 and Sympathy 0.54). Three factors (Relevance, Terminology and Confidence) distinguished EBP exposure groups (ANOVA p profile (EBP(2)) questionnaire is a reliable instrument with the ability to discriminate for three factors, between respondents with differing EBP exposures.

  6. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    Directory of Open Access Journals (Sweden)

    Formiga MF

    2018-05-01

    Full Text Available Magno F Formiga,1,2 Kathryn E Roach,1 Isabel Vital,3 Gisel Urdaneta,3 Kira Balestrini,3 Rafael A Calderon-Candelario,3,4 Michael A Campos,3,4,* Lawrence P Cahalin1,* 1Department of Physical Therapy, University of Miami Miller School of Medicine, Coral Gables, FL, USA; 2CAPES Foundation, Ministry of Education of Brazil, Brasilia, Brazil; 3Pulmonary Section, Miami Veterans Administration Medical Center, Miami, FL, USA; 4Division of Pulmonary, Allergy, Critical Care and Sleep Medicine, University of Miami Miller School of Medicine, Miami, FL, USA *These authors contributed equally to this work Purpose: The Test of Incremental Respiratory Endurance (TIRE provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP over time. The integration of MIP over inspiratory duration (ID provides the sustained maximal inspiratory pressure (SMIP. Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods: Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results: All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP

  7. A Structured Clinical Interview for Kleptomania (SCI-K): preliminary validity and reliability testing.

    Science.gov (United States)

    Grant, Jon E; Kim, Suck Won; McCabe, James S

    2006-06-01

    Kleptomania presents difficulties in diagnosis for clinicians. This study aimed to develop and test a DSM-IV-based diagnostic instrument for kleptomania. To assess for current kleptomania the Structured Clinical Interview for Kleptomania (SCI-K) was administered to 112 consecutive subjects requesting psychiatric outpatient treatment for a variety of disorders. Reliability and validity were determined. Classification accuracy was examined using the longitudinal course of illness. The SCI-K demonstrated excellent test-retest (Phi coefficient = 0.956 (95% CI = 0.937, 0.970)) and inter-rater reliability (phi coefficient = 0.718 (95% CI = 0.506, 0.848)) in the diagnosis of kleptomania. Concurrent validity was observed with a self-report measure using DSM-IV kleptomania criteria (phi coefficient = 0.769 (95% CI = 0.653, 0.850)). Discriminant validity was observed with a measure of depression (point biserial coefficient = -0.020 (95% CI = -0.205, 0.166)). The SCI-K demonstrated both high sensitivity and specificity based on longitudinal assessment. The SCI-K demonstrated excellent reliability and validity in diagnosing kleptomania in subjects presenting with various psychiatric problems. These findings require replication in larger groups, including non-psychiatric populations, to examine their generalizability. Copyright (c) 2006 John Wiley & Sons, Ltd.

  8. Reliability and validity of the Dutch Recovery Stress Questionnaire for athletes

    NARCIS (Netherlands)

    Nederhof, Esther; Brink, Michel S.; Lemmink, Koen A. P. M.

    2008-01-01

    The purpose of the present study was to investigate the cross-cultural validity of the Recovery Stress Questionnaire for Athletes (RESTQ-sport) by analysing reliability and validity of a Dutch translation. Two studies were performed to assess test-retest reliability with a one week interval,

  9. Reliability and validity of the Incontinence Quiz-Turkish version.

    Science.gov (United States)

    Kara, Kerime C; Çıtak Karakaya, İlkim; Tunalı, Nur; Karakaya, Mehmet G

    2018-01-01

    The aim of this study was to investigate the reliability and validity of the Turkish version of the Incontinence Quiz, which was developed by Branch et al. (1994), to assess women's knowledge of and attitudes toward urinary incontinence. Comprehensibility of the Turkish version of the 14-item Incontinence Quiz, which was prepared following translation-back translation procedures, was tested on a pilot group of eight women, and its internal reliability, test-retest reliability and construct validity were assessed in 150 women who attended the gynecology clinics of three hospitals in İçel, Turkey. Physical and sociodemographic characteristics and presence of incontinence complaints were also recorded. Data were analyzed at the 0.05 alpha level, using SPSS version 22. The scale had good reliability and validity. The internal reliability coefficient (Cronbach α) was 0.80, test-retest correlation coefficients were 0.83-0.94; and with regard to construct validity, Kaiser-Meyer-Olkin coefficient was 0.76 and Barlett sphericity test was 562.777 (P = 0.000). Turkish version of the Incontinence Quiz had a four-factor structure, with Eigenvalues ranging from 1.17 to 4.08. The Incontinence Quiz-Turkish version is a highly comprehensible, reliable and valid scale, which may be used to assess Turkish-speaking women's knowledge of and attitudes toward urinary incontinence. © 2017 Japan Society of Obstetrics and Gynecology.

  10. Interna konzistencija i retest pouzdanost hrvatske inačice PAQ-C upitnika

    OpenAIRE

    Podnar, Hrvoje; Kunješić, Mateja; Radman, Ivan

    2017-01-01

    The aim of the study was to determine internal consistency and retest reliability of the Croatian version of PAQ-C on a sample of 6-10 years old children and to report physical activity levels of elementary school pupils. The same set of questions was administered to the pupils on two different occasions, three weeks apart. Both testing rounds for 8-10 years old pupils were conducted at school in the presence of an experienced researcher. In contrast, the 6-8 years old pupils took the questio...

  11. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    Science.gov (United States)

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the

  12. Reliability, Validity, and Minimal Detectable Change of Balance Evaluation Systems Test and Its Short Versions in Older Cancer Survivors: A Pilot Study.

    Science.gov (United States)

    Huang, Min H; Miller, Kara; Smith, Kristin; Fredrickson, Kayle; Shilling, Tracy

    2016-01-01

    Cancer is primarily a disease of older adults. About 77% of all cancers are diagnosed in persons aged 55 years and older. Cancer and its treatment can cause diverse sequelae impacting body systems underlying balance control. No study has examined the psychometric properties of balance assessment tools in older cancer survivors, presenting a significant challenge in the selection of outcome measures for clinicians treating this fast-growing population. This study aimed to determine the reliability, validity, and minimal detectable change (MDC) of the Balance Evaluation System Test (BESTest), Mini-Balance Evaluation Systems Test (Mini-BESTest), and Brief-Balance Evaluation Systems Test (Brief-BESTest) in community-dwelling older cancer survivors. This study was a cross-sectional design. Twenty breast and 8 prostate cancer survivors participated [age (SD) = 68.4 (8.13) years]. The BESTest and Activity-specific Balance Confidence (ABC) Scale were administered during the first session. Scores of Mini-BESTest and Brief-BESTest were extracted on the basis of the scores of BESTest. The BESTest was repeated within 1 to 2 weeks by the same rater to determine the test-retest reliability. For the analysis of the inter-rater reliability, 21 participants were randomly selected to be evaluated by 2 raters. A primary rater administered the test. The 2 raters independently and concurrently scored the performance of the participants. Each rater recorded the ratings separately on the scoring sheet. No discussion among the raters was allowed throughout the testing. Intraclass correlation coefficients (ICCs), standard error of measurement, minimal detectable change (MDC), and Bland-Altman plots were calculated. Concurrent validity of these balance tests with the ABC Scale was examined using the Spearman correlation. The BESTest, Mini-BESTest, and Brief-BESTest had high test-retest (ICC = 0.90-0.94) and interrater reliability (ICC = 0.86-0.96), small standard error of measurement (0

  13. Test-retest assessment of cortical activation induced by repetitive transcranial magnetic stimulation with brain atlas-guided optical topography

    Science.gov (United States)

    Tian, Fenghua; Kozel, F. Andrew; Yennu, Amarnath; Croarkin, Paul E.; McClintock, Shawn M.; Mapes, Kimberly S.; Husain, Mustafa M.; Liu, Hanli

    2012-11-01

    Repetitive transcranial magnetic stimulation (rTMS) is a technology that stimulates neurons with rapidly changing magnetic pulses with demonstrated therapeutic applications for various neuropsychiatric disorders. Functional near-infrared spectroscopy (fNIRS) is a suitable tool to assess rTMS-evoked brain responses without interference from the magnetic or electric fields generated by the TMS coil. We have previously reported a channel-wise study of combined rTMS/fNIRS on the motor and prefrontal cortices, showing a robust decrease of oxygenated hemoglobin concentration (Δ[HbO2]) at the sites of 1-Hz rTMS and the contralateral brain regions. However, the reliability of this putative clinical tool is unknown. In this study, we develop a rapid optical topography approach to spatially characterize the rTMS-evoked hemodynamic responses on a standard brain atlas. A hemispherical approximation of the brain is employed to convert the three-dimensional topography on the complex brain surface to a two-dimensional topography in the spherical coordinate system. The test-retest reliability of the combined rTMS/fNIRS is assessed using repeated measurements performed two to three days apart. The results demonstrate that the Δ[HbO2] amplitudes have moderate-to-high reliability at the group level; and the spatial patterns of the topographic images have high reproducibility in size and a moderate degree of overlap at the individual level.

  14. Reliability of the detailed assessment of speed of handwriting on Flemish children.

    Science.gov (United States)

    Simons, Johan; Probst, Michel

    2014-01-01

    This study evaluates the reliability of the Detailed Assessment of Speed of Handwriting (DASH) in a Dutch-speaking sample of children. The sample included 650 boys and 513 girls (age range = 9-16 years). Handwriting speed measurements were obtained using the DASH. Interrater agreement, test-retest reliability, and internal consistency were calculated; gender and age effects were analyzed. Interrater agreement shows excellent reliability with intraclass correlation coefficients of at least 0.94. Test-retest correlations ranged from r = 0.65 to r = 0.81. The internal consistency measures, calculated with Cronbach's alpha, were between 0.88 and 0.94. Both gender and age have a significant effect on handwriting speed, with F (7.1144) = 17.43 (P handwriting speed of Dutch-speaking children. There is a tendency of girls to write faster than boys.

  15. Reliability of self-rated tinnitus distress and association with psychological symptom patterns.

    Science.gov (United States)

    Hiller, W; Goebel, G; Rief, W

    1994-05-01

    Psychological complaints were investigated in two samples of 60 and 138 in-patients suffering from chronic tinnitus. We administered the Tinnitus Questionnaire (TQ), a 52-item self-rating scale which differentiates between dimensions of emotional and cognitive distress, intrusiveness, auditory perceptual difficulties, sleep disturbances and somatic complaints. The test-retest reliability was .94 for the TQ global score and between .86 and .93 for subscales. Three independent analyses were conducted to estimate the split-half reliability (internal consistency) which was only slightly lower than the test-retest values for scales with a relatively small number of items. Reliability was sufficient also on the level of single items. Low correlation between the TQ and the Hopkins Symptom Checklist (SCL-90-R) indicate a distinct quality of tinnitus-related and general psychological disturbances.

  16. Reliability and Validity of the Greek Migraine Disability Assessment (MIDAS) Questionnaire.

    Science.gov (United States)

    Oikonomidi, Theodora; Vikelis, Michail; Artemiadis, Artemios; Chrousos, George P; Darviri, Christina

    2018-03-01

    The Migraine Disability Assessment (MIDAS) Questionnaire is a reliable and valid instrument for migraine-related disability. Such a tool is needed to quantify migraine-related disability in the Greek population. This validation study aims to assess the test-retest reliability, internal consistency, item discriminant and convergent validity of the Greek translation of the MIDAS. Adults diagnosed with migraine completed the MIDAS Questionnaire on two occasions 3 weeks apart to assess reliability, and completed the RAND-36 to assess validity. Participants (n = 152) had a median MIDAS score of 24 and mostly severe disability (58% were grade IV). The test-retest reliability analysis (N = 59) revealed excellent reliability for the total score. Internal consistency was α = 0.71 for initial and α = 0.82 for retest completion. For item discriminant validity, the correlations between each question and the total score were significant, with high correlations for questions 2-5 (range 0.67 ≤ r ≤ 0.79; p MIDAS score tended to have better wellbeing. Psychometric properties are comparable with those of other published validation studies of the MIDAS and the original. Findings on question 1 show that missing work/school days may be closely related with increased affect issues. The Greek version of the MIDAS Questionnaire has good reliability and validity. This study allowed for cross-cultural comparability of research findings.

  17. Reliability and Validity of the Turkish Version of the Voice-Related Quality of Life Measure.

    Science.gov (United States)

    Tezcaner, Zahide Çiler; Aksoy, Songül

    2017-03-01

    This study aims to test the validity and reliability of the Turkish version of the Voice-Related Quality of Life (V-RQOL) questionnaire. This is a nonrandomized, prospective study with control group. The questionnaire was administered to 249 individuals-130 with vocal complaint and 119 without-with a mean age of 37.8 ± 12.3 years. The Turkish version of the Voice Handicap Index (VHI) and perceptual voice evaluation measures were also administered at 2-14 days for retest reliability. The instrument was submitted to validity and reliability evaluation. The V-RQOL measure showed a strong internal consistency and test-retest reliability; the Cronbach's alpha coefficient for the overall V-RQOL was 0.969, the physical functioning domain was 0.949, and the social-emotional domain was 0.940. In the test-retest reliability test, the overall V-RQOL was found to be 0.989. The construct validity of the V-RQOL was determined based on the strength and direction of its relation to the VHI and the perceptual voice evaluation measure. The higher the VHI level, the lower the physical functioning, social-emotional, and overall score levels of the V-RQOL (r = -0.927, r = -0.912, r = -0.944, respectively; P reliability and validity and may play a crucial role in evaluating Turkish-speaking patients with voice disorders. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  18. Reliability and validity of the adapted Resistance Training Skills Battery for Children.

    Science.gov (United States)

    Furzer, Bonnie J; Bebich-Philip, Marc D; Wright, Kemi E; Reid, Siobhan L; Thornton, Ashleigh L

    2017-12-29

    Resistance training (RT) is emerging as a training modality to improve motor function and facilitate physical activity participation in children across the motor proficiency spectrum. Although RT competency assessments have been established and validated among adolescent cohorts, the extent to which these methods are suitable for assessing children's RT skills is unknown. This project aimed to assess the psychometric properties of the adapted Resistance Training Skills Battery for Children (RTSBc), in children with varying motor proficiency. Repeated measures design with 40 participants (M age=8.2±1.7years) displaying varying levels of motor proficiency. Participants performed the adapted RTSBc on two occasions, receiving a score for their execution of each component, in addition to an overall RT skill quotient child (RTSQc). Cronbach's alpha, intra-class correlation (ICC), Bland-Altman analysis, and typical error were used to assess test-retest reliability. To examine construct validity, exploratory factor analysis was performed alongside computing correlations between participants' muscle strength, motor proficiency, age, lean muscle mass, and RTSQc. The RTSBc displayed an acceptable level of internal consistency (alpha=0.86) and test-retest reliability (ICC range=0.86-0.99). Exploratory factor analysis supported internal test structure, with all six RT skills loading strongly on a single factor (range 0.56-0.89). Analyses of structural validity revealed positive correlations for RTSQc in relation to motor proficiency (r=0.52, preliability of the RTSBc, providing preliminary evidence that the RTSBc is appropriate for use in the assessment of children's RT competency. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  19. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    Science.gov (United States)

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. Sonographic measurements of the achilles tendon, plantar fascia, and heel fat pad are reliable: A test-retest intra- and intertester study.

    Science.gov (United States)

    Johannsen, Finn; Jensen, Signe; Stallknecht, Sandra E; Olsen, Lars Otto; Magnusson, S Peter

    2016-10-01

    To determine intra- and interobserver reliability and precision of sonographic (US) scanning in measuring thickness of the Achilles tendon, plantar fascia, and heel fat pad in patients with heel pain. Seventeen consecutive patients referred with heel pain were included. Two evaluators blinded to the diagnosis performed independently US scanning of both feet without any dialogue with the patient. The examiner left the room, and the next examiner entered. All patients had two US scans performed by each examiner. Two months later, the US images were randomly presented to the evaluators for measurements. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC), 95% limits of agreement (LOA), and typical error (TE). LOA was calculated as a percentage of the mean thickness of each structure to obtain a unitless parameter. We found excellent intratester reliability (ICC 0.78-0.98) and good intertester reliability using one measurement (ICC 0.72-0.91) and excellent (ICC 0.85-0.95) when using average of two measurements. The intratester agreements were good with LOA: 9.5-23.4% and TE: 3.4-8.4%. The intertester agreements were acceptable using one measurement with LOA: 16.1-36.4%, and better using two measurements with LOA: 14.4-33.2%. US is a reliable technique of measurement in the daily clinic, and one single measurement is sufficient. In research, we recommend that the same observer performs the US measurements, if one single scanning is preferred; if more researchers are involved, the average measurement of two US scans is recommended. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:480-486, 2016. © 2016 Wiley Periodicals, Inc.

  1. Characteristics and international comparability of the Finnish matrix sentence test in cochlear implant recipients.

    Science.gov (United States)

    Dietz, Aarno; Buschermöhle, Michael; Sivonen, Ville; Willberg, Tytti; Aarnisalo, Antti A; Lenarz, Thomas; Kollmeier, Birger

    2015-01-01

    The first Finnish sentence-based speech test in noise--the Finnish matrix sentence test--was recently developed. The aim of this study was to determine the characteristics of the new test with respect to test-retest reliability, speech recognition curve, and international comparability in Finnish cochlear implant (CI) recipients. The speech reception thresholds (SRT) were measured by means of an adaptive test procedure and compared with the results of the traditional Finnish word test. Additional measurements for concurrent slope and SRT estimation were conducted to determine the speech recognition curve and to check the test-retest reliability. The measurements were performed on 78 Finnish CI recipients. In a subset of 25 patients, additional measurements for test-retest reliability and slope determination were performed. The mean SRT was -3.5 ± 1.7 dB SNR, with only a weak correlation with the Finnish word test. Test-retest reliability was within ± 1 dB and the mean slope of the speech recognition curve was 14.6 ± 3.6 %/dB. The rehabilitation results were similar to the results published for the German matrix test. The Finnish matrix test was found to be suitable and efficient in CI recipients with similar characteristics as the German matrix test.

  2. Evaluation of Factorial Validity and Reliability of a Food Behavior Checklist for Low-Income Filipinos.

    Science.gov (United States)

    Suzuki, Asuka; Choi, So Yung; Lim, Eunjung; Tauyan, Socorro; Banna, Jinan C

    To examine factorial validity, test-retest reliability, and internal consistency of a Tagalog-language food behavior checklist (FBC) for a low-income Filipino population. Participants (n = 160) completed the FBC on 2 occasions 3 weeks apart. Factor structure was examined using principal component analysis. For internal consistency, Cronbach α was calculated. For test-retest reliability, Spearman correlation or intraclass correlation coefficient (ICC) was calculated between scores at the 2 points. All but 1 item loaded on 6 factors: fruit and vegetable quantity, fruit and vegetable variety, fast food, sweetened beverage, healthy fat, and diet quality. Cronbach α was .75 for the total scale (range, .39-.76 for subscales). Spearman correlation was 0.78 (ICC, 0.79) for the total scale (range, 0.66-0.80 [ICC, 0.68-0.80] for subscales). The FBC demonstrated adequate factorial validity, test-retest reliability, and internal consistency. With additional testing, the FBC may be used to evaluate the US Department of Agriculture's nutrition education programs for Tagalog speakers. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  3. The Validity and Reliability of the Mobbing Scale (MS)

    Science.gov (United States)

    Yaman, Erkan

    2009-01-01

    The aim of this research is to develop the Mobbing Scale and examine its validity and reliability. The sample of the study consisted of 515 persons from Sakarya and Bursa. In this study, construct validity, internal consistency, test-retest reliability, and item analysis of the scale were examined. As a result of factor analysis for construct…

  4. Prediction of safety critical software operational reliability from test reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1999-01-01

    It has been a critical issue to predict the safety critical software reliability in nuclear engineering area. For many years, many researches have focused on the quantification of software reliability and there have been many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is however on the operational reliability rather than on the test reliability. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, from testing to operation, testing environment factors comprising the aging factor and the coverage factor are developed in this paper and used to predict the ultimate operational reliability with the failure data in testing phase. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results show that the proposed method can estimate the operational reliability accurately. (Author). 14 refs., 1 tab., 1 fig

  5. Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility.

    Science.gov (United States)

    Muyor, José M

    2017-09-01

    The aims of the current study were 1) to evaluate the validity of the WIMU ® system for measuring hamstring muscle extensibility in the passive straight leg raise (PSLR) test using an inclinometer for the criterion and 2) to determine the test-retest reliability of the WIMU ® system to measure hamstring muscle extensibility during the PSLR test. 55 subjects were evaluated on 2 separate occasions. Data from a Unilever inclinometer and WIMU ® system were collected simultaneously. Intraclass correlation coefficients (ICCs) for the validity were very high (0.983-1); a very low systematic bias (-0.21°--0.42°), random error (0.05°-0.04°) and standard error of the estimate (0.43°-0.34°) were observed (left-right leg, respectively) between the 2 devices (inclinometer and the WIMU ® system). The R 2 between the devices was 0.999 (p<0.001) in both the left and right legs. The test-retest reliability of the WIMU ® system was excellent, with ICCs ranging from 0.972-0.995, low coefficients of variation (0.01%), and a low standard error of the estimate (0.19-0.31°). The WIMU ® system showed strong concurrent validity and excellent test-retest reliability for the evaluation of hamstring muscle extensibility in the PSLR test. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Validity and Reliability of the Bahasa Melayu Version of the Migraine Disability Assessment Questionnaire

    Directory of Open Access Journals (Sweden)

    Munvar Miya Shaik

    2014-01-01

    Full Text Available Background. The study was designed to determine the validity and reliability of the Bahasa Melayu version (MIDAS-M of the Migraine Disability Assessment (MIDAS questionnaire. Methods. Patients having migraine for more than six months attending the Neurology Clinic, Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia, were recruited. Standard forward and back translation procedures were used to translate and adapt the MIDAS questionnaire to produce the Bahasa Melayu version. The translated Malay version was tested for face and content validity. Validity and reliability testing were further conducted with 100 migraine patients (1st administration followed by a retesting session 21 days later (2nd administration. Results. A total of 100 patients between 15 and 60 years of age were recruited. The majority of the patients were single (66% and students (46%. Cronbach’s alpha values were 0.84 (1st administration and 0.80 (2nd administration. The test-retest reliability for the total MIDAS score was 0.73, indicating that the MIDAS-M questionnaire is stable; for the five disability questions, the test-retest values ranged from 0.77 to 0.87. Conclusion. The MIDAS-M questionnaire is comparable with the original English version in terms of validity and reliability and may be used for the assessment of migraine in clinical settings.

  7. Cultural Adaptation of the Portuguese Version of the "Sniffin' Sticks" Smell Test: Reliability, Validity, and Normative Data.

    Science.gov (United States)

    Ribeiro, João Carlos; Simões, João; Silva, Filipe; Silva, Eduardo D; Hummel, Cornelia; Hummel, Thomas; Paiva, António

    2016-01-01

    The cross-cultural adaptation and validation of the Sniffin`Sticks test for the Portuguese population is described. Over 270 people participated in four experiments. In Experiment 1, 67 participants rated the familiarity of presented odors and seven descriptors of the original test were adapted to a Portuguese context. In Experiment 2, the Portuguese version of Sniffin`Sticks test was administered to 203 healthy participants. Older age, male gender and active smoking status were confirmed as confounding factors. The third experiment showed the validity of the Portuguese version of Sniffin`Sticks test in discriminating healthy controls from patients with olfactory dysfunction. In Experiment 4, the test-retest reliability for both the composite score (r71 = 0.86) and the identification test (r71 = 0.62) was established (pPortuguese version of Sniffin`Sticks test is provided, showing good validity and reliability and effectively distinguishing patients from healthy controls with high sensitivity and specificity. The Portuguese version of Sniffin`Sticks test identification test is a clinically suitable screening tool in routine outpatient Portuguese settings.

  8. Reliability and validity of the Spanish version of the Child Health and Illness Profile (CHIP Child-Edition, Parent Report Form (CHIP-CE/PRF

    Directory of Open Access Journals (Sweden)

    Tebé Cristian

    2010-08-01

    Full Text Available Abstract Background The objectives of the study were to assess the reliability, and the content, construct, and convergent validity of the Spanish version of the CHIP-CE/PRF, to analyze parent-child agreement, and compare the results with those of the original U.S. version. Methods Parents from a representative sample of children aged 6-12 years were selected from 9 primary schools in Barcelona. Test-retest reliability was assessed in a convenience subsample of parents from 2 schools. Parents completed the Spanish version of the CHIP-CE/PRF. The Achenbach Child Behavioural Checklist (CBCL was administered to a convenience subsample. Results The overall response rate was 67% (n = 871. There was no floor effect. A ceiling effect was found in 4 subdomains. Reliability was acceptable at the domain level (internal consistency = 0.68-0.86; test-retest intraclass correlation coefficients = 0.69-0.85. Younger girls had better scores on Satisfaction and Achievement than older girls. Comfort domain score was lower (worse in children with a probable mental health problem, with high effect size (ES = 1.45. The level of parent-child agreement was low (0.22-0.37. Conclusions The results of this study suggest that the parent version of the Spanish CHIP-CE has acceptable psychometric properties although further research is needed to check reliability at sub-domain level. The CHIP-CE parent report form provides a comprehensive, psychometrically sound measure of health for Spanish children 6 to 12 years old. It can be a complementary perspective to the self-reported measure or an alternative when the child is unable to complete the questionnaire. In general, the results are similar to the original U.S. version.

  9. Reliability and Validity of the Beijing Version of the Montreal Cognitive Assessment in the Evaluation of Cognitive Function of Adult Patients with OSAHS.

    Science.gov (United States)

    Chen, Xiong; Zhang, Rui; Xiao, Ying; Dong, Jiaqi; Niu, Xun; Kong, Weijia

    2015-01-01

    The patients with obstructive sleep apnea hypopnea syndrome (OSAHS) tend to develop cognitive deficits, which usually go unrecognized, and can affect their daily life. The Beijing version of the Montreal cognitive assessment (MoCA-BJ), a Chinese version of MoCA, has been used for the assessment of cognitive functions of OSAHS patients in clinical practice. So far, its reliability and validity have not been tested. This study examined the reliability and validity of MoCA-BJ in a cohort of adult OSAHS patients. 152 OSAHS patients, ranging from mild, moderate to severe, 49 primary snoring subjects and 40 normal controls were evaluated for cognitive functions by employing both MoCA-BJ and the Mini Mental State Examination (MMSE). Forty of them were re-tested by MoCA-BJ 14 days after the first test. Internal consistency, test-retest reliability, discriminate and concurrent validity of MoCA-BJ were analyzed. Internal consistency reliability by Cronbach's alpha was adequate (0.73). Intra-class correlation coefficient (ICC), an measure of test-retest reliability, was 0.87 (Preliable and stable. The MoCA-BJ was capable of detecting cognitive dysfunction by visuospatial and total MoCA-BJ score.

  10. The prone bridge test: Performance, validity, and reliability among older and younger adults.

    Science.gov (United States)

    Bohannon, Richard W; Steffl, Michal; Glenney, Susan S; Green, Michelle; Cashwell, Leah; Prajerova, Kveta; Bunn, Jennifer

    2018-04-01

    The prone bridge maneuver, or plank, has been viewed as a potential alternative to curl-ups for assessing trunk muscle performance. The purpose of this study was to assess prone bridge test performance, validity, and reliability among younger and older adults. Sixty younger (20-35 years old) and 60 older (60-79 years old) participants completed this study. Groups were evenly divided by sex. Participants completed surveys regarding physical activity and abdominal exercise participation. Height, weight, body mass index (BMI), and waist circumference were measured. On two occasions, 5-9 days apart, participants held a prone bridge until volitional exhaustion or until repeated technique failure. Validity was examined using data from the first session: convergent validity by calculating correlations between survey responses, anthropometrics, and prone bridge time, known groups validity by using an ANOVA comparing bridge times of younger and older adults and of men and women. Test-retest reliability was examined by using a paired t-test to compare prone bridge times for Session1 and Session 2. Furthermore, an intraclass correlation coefficient (ICC) was used to characterize relative reliability and minimal detectable change (MDC 95% ) was used to describe absolute reliability. The mean prone bridge time was 145.3 ± 71.5 s, and was positively correlated with physical activity participation (p ≤ 0.001) and negatively correlated with BMI and waist circumference (p ≤ 0.003). Younger participants had significantly longer plank times than older participants (p = 0.003). The ICC between testing sessions was 0.915. The prone bridge test is a valid and reliable measure for evaluating abdominal performance in both younger and older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. The Dutch language anterior cruciate ligament return to sport after injury scale (ACL-RSI) - validity and reliability.

    Science.gov (United States)

    Slagers, Anton J; Reininga, Inge H F; van den Akker-Scheek, Inge

    2017-02-01

    The ACL-Return to Sport after Injury scale (ACL-RSI) measures athletes' emotions, confidence in performance, and risk appraisal in relation to return to sport after ACL reconstruction. Aim of this study was to study the validity and reliability of the Dutch version of the ACL-RSI (ACL-RSI (NL)). Total 150 patients, who were 3-16 months postoperative, completed the ACL-RSI(NL) and 5 other questionnaires regarding psychological readiness to return to sports, knee-specific physical functioning, kinesiophobia, and health-specific locus of control. Construct validity of the ACL-RSI(NL) was determined with factor analysis and by exploring 10 hypotheses regarding correlations between ACL-RSI(NL) and the other questionnaires. For test-retest reliability, 107 patients (5-16 months postoperative) completed the ACL-RSI(NL) again 2 weeks after the first administration. Cronbach's alpha, Intraclass Correlation Coefficient (ICC), SEM, and SDC, were calculated. Bland-Altman analysis was conducted to assess bias between test and retest. Nine hypotheses (90%) were confirmed, indicating good construct validity. The ACL-RSI(NL) showed good internal consistency (Cronbach's alpha 0.94) and test-retest reliability (ICC 0.93). SEM was 5.5 and SDC was 15. A significant bias of 3.2 points between test and retest was found. Therefore, the ACL-RSI(NL) can be used to investigate psychological factors relevant to returning to sport after ACL reconstruction.

  12. Validation of the Stroke Specific Quality of Life Scale (SS-QOL): test of reliability and validity of the Danish version (SS-QOL-DK).

    Science.gov (United States)

    Muus, Ingrid; Williams, Linda S; Ringsberg, Karin C

    2007-07-01

    To test the reliability and validity of the Danish version of the Stroke Specific Quality of Life Scale version 2.0 (SS-QOL-DK), an instrument for evaluation of health-related quality of life. A correlational study. A stroke unit that provides acute care and rehabilitation for stroke patients in Frederiksborg County, Denmark. One hundred and fifty-two stroke survivors participated; 24 of these performed test-retest. Questionnaires were sent out and returned by mail. A subsequent telephone interview assessed functional level and missing items. Test-retest was measured using Spearman's r, internal consistency was estimated using Cronbach's alpha, and evaluation of floor and ceiling values in proportion of minimum and maximum scores. Construct validity was assessed by comparing patients' scores on the SS-QOL-DK with those obtained by other test methods: Beck's Depression Index, the General Health Survey Short Form 36 (SF-36), the Barthel Index and the National Institutes of Health Stroke Scale, evaluating shared variance using coefficient of determination, r2. Comparing groups with known scores assessed known-group validity. Convergent and discriminant validity were assessed. Test-retest of SS-QOL-DK showed excellent stability, Spearman's r = 0.65-0.99. Internal consistency for all domains showed Cronbach's alpha = 0.81-0.94. Missing items rate was 1.0%. Most SS-QOL-DK domains showed moderately shared variance with similar domains of other test methods, r2 = 0.03-0.62. Groups with known differences showed statistically significant difference in scores. Item-to-scale correlation coefficients of 0.37-0.88 supported convergent validity. SS-QOL-DK is a reliable and valid instrument for measuring self-reported health-related quality of life on group level among people with mild to moderate stroke.

  13. The Persian version of auditory word discrimination test (P-AWDT) for children: Development, validity, and reliability.

    Science.gov (United States)

    Hashemi, Nassim; Ghorbani, Ali; Soleymani, Zahra; Kamali, Mohmmad; Ahmadi, Zohreh Ziatabar; Mahmoudian, Saeid

    2018-07-01

    Auditory discrimination of speech sounds is an important perceptual ability and a precursor to the acquisition of language. Auditory information is at least partially necessary for the acquisition and organization of phonological rules. There are few standardized behavioral tests to evaluate phonemic distinctive features in children with or without speech and language disorders. The main objective of the present study was the development, validity, and reliability of the Persian version of auditory word discrimination test (P-AWDT) for 4-8-year-old children. A total of 120 typical children and 40 children with speech sound disorder (SSD) participated in the present study. The test comprised of 160 monosyllabic paired-words distributed in the Forms A-1 and the Form A-2 for the initial consonants (80 words) and the Forms B-1 and the Form B-2 for the final consonants (80 words). Moreover, the discrimination of vowels was randomly included in all forms. Content validity was calculated and 50 children repeated the test twice with two weeks of interval (test-retest reliability). Further analysis was also implemented including validity, intraclass correlation coefficient (ICC), Cronbach's alpha (internal consistency), age groups, and gender. The content validity index (CVI) and the test-retest reliability of the P-AWDT were achieved 63%-86% and 81%-96%, respectively. Moreover, the total Cronbach's alpha for the internal consistency was estimated relatively high (0.93). Comparison of the mean scores of the P-AWDT in the typical children and the children with SSD revealed a significant difference. The results revealed that the group with SSD had greater severity of deficit than the typical group in auditory word discrimination. In addition, the difference between the age groups was statistically significant, especially in 4-4.11-year-old children. The performance of the two gender groups was relatively same. The comparison of the P-AWDT scores between the typical children

  14. Reliability of the Phi angle to assess rotational alignment of the talar component in total ankle replacement.

    Science.gov (United States)

    Manzi, Luigi; Villafañe, Jorge Hugo; Indino, Cristian; Tamini, Jacopo; Berjano, Pedro; Usuelli, Federico Giuseppe

    2017-11-08

    The purpose of this study was to investigate the test-retest reliability of the Phi angle in patients undergoing total ankle replacement (TAR) for end stage ankle osteoarthritis (OA) to assess the rotational alignment of the talar component. Retrospective observational cross-sectional study of prospectively collected data. Post-operative anteroposterior radiographs of the foot of 170 patients who underwent TAR for the ankle OA were evaluated. Three physicians measured Phi on the 170 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), inter and intra-observer agreement were evaluated. Test-retest reliability of Phi angle measurement was excellent for patients with Hintegra TAR (ICC=0.995; pPhi angle measurement between patients with Hintegra vs. Zimmer implants (p>0.05). Measurement of Phi angle on weight-bearing dorsoplantar radiograph showed an excellent reliability among orthopaedic surgeons in determining the position of the talar component in the axial plane. Level II, cross sectional study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  15. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable...... with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91. Conclusions: The One Leg Stand Test can be used to test postural balance...

  16. The Validity and Reliability of Autism Behavior Checklist

    Directory of Open Access Journals (Sweden)

    Negin Yousefi

    2015-11-01

    Full Text Available  Objectives: The aim of this study was to evaluate the psychometric features of the Persian version of the Autism Behavior Checklist (ABC.  Method:The International Quality of Life Assessment (IQOLA approach was used to translate the English ABC into Persian. A total sample of 184 parents of children including 114 children with autism disorder (mean age =7.21, SD =1.65 and 70 typically developing children (mean age = 6.82, SD =1.75 completed the ABC. Internal consistency, test-retest reliability, concurrent and discriminant validity, and cut-off score were assessed. Results: The results of this study revealed that the Persian version of the ABC has an acceptable degree of internal consistency (.73. Test–retest comparisons using interclass correlation confirmed the instrument’s time stability (.83. The instrument’s concurrent validity with Gilliam Autism Rating Scale (GARS was verified; the correlation between total scores was .94. In the discriminant validity, the autism group had significantly higher scores compared to the normal group. Receiver Operating Characteristic (ROC analysis revealed that individuals with total scores below 25 are less likely to be in the autism group. Conclusion:The Persian version of the ABC can be used as an initial screening tool in clinical contexts.

  17. Temporal stability of preferences and willingness to pay for natural areas in choice experiments: A test-retest

    NARCIS (Netherlands)

    Schaafsma, M.; Brouwer, R.; Liekens, I.; de Nocker, L.

    2014-01-01

    The main objective of this paper is to test the temporal stability of stated preferences and willingness to pay (WTP) values from a Choice Experiment (CE) in a test-retest. The same group of participants was asked the same choice tasks in an internet-based CE, conducted twice with a time interval of

  18. Diurnal variation and reliability of the urine lactate concentration after maximal exercise.

    Science.gov (United States)

    Nikolaidis, Stefanos; Kosmidis, Ioannis; Sougioultzis, Michail; Kabasakalis, Athanasios; Mougios, Vassilis

    2018-01-01

    The postexercise urine lactate concentration is a novel valid exercise biomarker, which has exhibited satisfactory reliability in the morning hours under controlled water intake. The aim of the present study was to investigate the diurnal variation of the postexercise urine lactate concentration and its reliability in the afternoon hours. Thirty-two healthy children (11 boys and 21 girls) and 23 adults (13 men and 10 women) participated in the study. All participants performed two identical sessions of eight 25 m bouts of maximal freestyle swimming executed every 2 min with passive recovery in between. These sessions were performed in the morning and afternoon and were separated by 3-4 days. Adults performed an additional afternoon session that was also separated by 3-4 days. All swimmers drank 500 mL of water before and another 500 mL after each test. Capillary blood and urine samples were collected before and after each test for lactate determination. Urine creatinine, urine density and body water content were also measured. The intraclass correlation coefficient was used as a reliability index between the morning and afternoon tests, as well as between the afternoon test and retest. Swimming performance and body water content exhibited excellent reliability in both children and adults. The postexercise blood lactate concentration did not show diurnal variation, showing a good reliability between the morning and afternoon tests, as well as high reliability between the afternoon test and retest. The postexercise urine density and lactate concentration were affected by time of day. However, when lactate was normalized to creatinine, it exhibited excellent reliability in children and good-to-high reliability in adults. The postexercise urine lactate concentration showed high reliability between the afternoon test and retest, independent of creatinine normalization. The postexercise blood and urine lactate concentrations were significantly correlated in all

  19. Reliability and accuracy of a video analysis protocol to assess core ability.

    Science.gov (United States)

    McDonald, Dawn A; Delgadillo, James Q; Fredericson, Michael; McConnell, Jennifer; Hodgins, Melissa; Besier, Thor F

    2011-03-01

    To develop and test a method to measure core ability in healthy athletes with 2-dimensional video analysis software (SiliconCOACH). Specific objectives were to: (1) develop a standardized exercise battery with progressions of increasing difficulty to evaluate areas of core ability in elite athletes; (2) develop an objective and quantitative grading rubric with the use of video analysis software; (3) assess the test-retest reliability of the exercise battery; (4) assess the interrater and intrarater reliability of the video analysis system; and (5) assess the accuracy of the assessment. Test-retest repeatability and accuracy. Testing was conducted in the Stanford Human Performance Laboratory, Stanford University, Stanford, CA. Nine female gymnasts currently training with the Stanford Varsity Women's Gymnastics Team participated in testing. Participants completed a test battery composed of planks, side planks, and leg bridges of increasing difficulty. Subjects completed two 20-minute testing sessions within a 4- to 10-day period. Two-dimensional sagittal-plane video was captured simultaneously with 3-dimensional motion capture. The main outcome measures were pelvic displacement and time that elapsed until failure occurred, as measured with SiliconCOACH video analysis software. Test-retest and interrater and intrarater reliability of the video analysis measures was assessed. Accuracy as compared with 3-dimensional motion capture also was assessed. Levels reached during the side planks and leg bridges had an excellent test-retest correlation (r(2) = 0.84, r(2) = 0.95). Pelvis displacements measured by examiner 1 and examiner 2 had an excellent correlation (r(2) = 0.86, intraclass correlation coefficient = 0.92). Pelvis displacements measured by examiner 1 during independent grading sessions had an excellent correlation (r(2) = 0.92). Pelvis displacements from the plank and from a set of combined plank and side plank exercises both had an excellent correlation with 3

  20. Reliability and main findings of the FEES-Tensilon Test in patients with myasthenia gravis and dysphagia.

    Science.gov (United States)

    Im, Sun; Suntrup-Krueger, Sonja; Colbow, Sigrid; Sauer, Sonja; Claus, Inga; Meuth, Sven G; Dziewas, Rainer; Warnecke, Tobias

    2018-05-26

    Diagnosis of pharyngeal dysphagia caused by myasthenia gravis (MG) based on clinical examination alone is often challenging. Flexible endoscopic evaluation of swallowing (FEES) combined with Tensilon (edrophonium) application, referred to as the FEES-Tensilon Test, was developed to improve diagnostic accuracy and to detect the main symptoms of pharyngeal dysphagia in MG. Here we investigated inter- and intra-rater reliability of the FEES-Tensilon Test and analyzed the main endoscopic findings. Four experienced raters reviewed a total of 20 FEES-Tensilon-Test videos in randomized order. Residue severity was graded at 4 different pharyngeal spaces before and after Tensilon administration. All interpretations were performed twice per rater, 4 weeks apart (a total of 160 scorings). Intra-rater test-retest reliability and inter-rater reliability levels were calculated. The most frequent FEES findings in MG patients before Tensilon application were prominent residues of semi solids spread all over the hypopharynx in varying locations. The reliability level in the interpretation of the FEES-Tensilon test was excellent regardless of the raters' profession or years of experience with FEES. All 4 raters showed high inter- and intra- reliability levels in interpreting the FEES-Tensilon Test based on residue clearance (kappa=0.922, 0.981). Degree of residue normalization in the vallecular space after Tensilon application showed the highest inter- and intra-rater reliability level (kappa=0.863, 0.957) followed by the epiglottis (kappa=0.813, 0.946) and pyriform sinuses (kappa=0.836, 0.929). Interpretation of the FEES-Tensilon Test based on residue severity and degree of Tensilon clearance, especially in the vallecular space, is consistent and reliable. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.