WorldWideScience

Sample records for acceleration dsa operators

  1. DSA in digital replantations

    International Nuclear Information System (INIS)

    Wang Liuhong; Chao Ming; Jiang Dingyao; Zhang Guangqiang; Wu Jianjun; Chen Xianyi; Li Bin; Sun Jihong

    2008-01-01

    Objective: To assess revascularization and vessel anastomosis in digital replantations with DSA. Methods: Twelve cases of digital replantations underwent digital subtract angiography during 2 to 4 days after fingers reattachment. The vessel anastomosis, hemodynamics, stenosis and discontinuation were investigated. The unobstructed and smooth anastomosis was suggested as early stage survival of the reattached fingers, the spasm and stenosis of the reattached vessels were considered as mild vascular crisis, and the discontinuation of hemodynamics were indicated as severe vascular crisis. Results: The total 27 vessels were clearly displayed on DSA. Of these vessels, 23 vessels were unobstructed and smooth, all digits were survived. Diagnosis coincidence of early stage survival was 100% (23/23). Two vessels were obstructed, which were testified having thrombus by operation research. The other 2 vessels were spasm, the digits were also survived ultimately by expectant treatment. All 4 abnormal vessel anatomosis were found by DSA. Conclusion: DSA is important modality in assessing revascularization and blood circulation for digital replantations, guiding in dealing with the vascular crisis, and in predicting early stage survival of the reattached digits. (authors)

  2. The DSA findings and interventional therapy of hepatic alveolar echinococcus

    International Nuclear Information System (INIS)

    Ren Weixin; Xiao Xiangsheng; Chen Peng; Ma Jun

    2004-01-01

    Objective: To analyse the DSA findings of hepatic alveolar echinococcus (HAE) and evaluate the feasibility of the interventional therapy. Methods: Eight patients with HAE were all examined by DSA, CT and lab test. Three of them were performed the transcatheter arterial embolization by iodized oil. All of them were confirmed by surgical operation and followed-up for three months. Results: The DSA findings of HAE included hepatic arterial curling and enlargement with hypertrophied circled encircling as typical 'handed ball'. Eight cases presented the ring stain during the capillary stage. After embolization, the retention of iodized oil was revealed by DSA in 3 cases. CT three months later showed fine iodized oil retention and the enlarged necrosis. Ischemic necrosis around the lesion and the cut margins were clearly seen in operation biopsy. Conclusions: HAE possesses special DSA findings and interventional therapy is a new therapeutic method of choice. (authors)

  3. 'Table step-shift DSA' for peripheral angiography

    International Nuclear Information System (INIS)

    Kojima, Kanji; Seo, Hiroyuki; Kawase, Yoshirou; Hino, Ichirou; Satou, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Tamai, Toyosato; Tanabe, Masatada

    1987-01-01

    We developed a new technique of digital subtraction angiography (DSA) for peripheral angiography, which make it possible to obtain DSA images of two contiguous positions with a single injection of contrast material. It is made by the combination with DSA system (Toshiba Digiformer X-03A) and the angio-table with step-shift function (Toshiba CAT-FX), which is widely used in the conventional angiography for pelvis and lower extrimities. When DSA image of the first position is sufficiently demonstrated, the table is semi-automatically translated to the second position by the switching of the operator, observing TV-monitor. The images are stored into the digital image disc. DSA image of the second position can be given by the remasking method. We examined 40 times ''table step-shift DSA'' on 18 patients, which consist of 19 IVDSA with central injection and 21 IADSA for abdomen and lower leg. In 90 % and 72.5 % of images the procedure was diagnostic for the 1st and 2nd position respectively. The causes of nondiagnostic image were mostly from the prolonged blood flow and its difference in both sides. With this technique we could reduce the contrast material load and the time consumption of the examination. (author)

  4. The study of the value of applying the special functions of DSA during uterine artery embolization

    International Nuclear Information System (INIS)

    Wang Ting; Zhao Zhenhua; Lv Weigong

    2007-01-01

    Objective: To study the value of applying the special functions of DSA during uterine artery embolization. Methods: 122 cases were performed uterine artery embolization, including 67 cases with traditional operation and 55 cases with applying the special functions of DSA: rotary DSA angiography, the best work position and road map technology. We recorded the correlative operative indices to compare and analyse the mean exposure time, the mean operative time, the mean dosage of contrast medium, the probability of vasospasm and injury of blood vessel during operation. Results: The mean exposure time, mean operative time and the mean dosage of contrast medium were reduced with the special functions of DSA during uterine artery embolization. There is significant difference between traditional operation and the operation applying the special functions of DSA (P<0.01). Conclusion: Applying the special functions of DSA during uterine artery embolization can reduce the operative time, operative risk and economic burden. (authors)

  5. Diffusive Shock Acceleration and Turbulent Reconnection

    Science.gov (United States)

    Garrel, Christian; Vlahos, Loukas; Isliker, Heinz; Pisokas, Theophilos

    2018-05-01

    Diffusive Shock Acceleration (DSA) cannot efficiently accelerate particles without the presence of self-consistently generated or pre-existing strong turbulence (δB/B ˜ 1) in the vicinity of the shock. The problem we address in this article is: if large amplitude magnetic disturbances are present upstream and downstream of a shock then Turbulent Reconnection (TR) will set in and will participate not only in the elastic scattering of particles but also in their heating and acceleration. We demonstrate that large amplitude magnetic disturbances and Unstable Current Sheets (UCS), spontaneously formed in the strong turbulence in the vicinity of a shock, can accelerate particles as efficiently as DSA in large scale systems and on long time scales. We start our analysis with "elastic" scatterers upstream and downstream and estimate the energy distribution of particles escaping from the shock, recovering the well known results from the DSA theory. Next we analyze the additional interaction of the particles with active scatterers (magnetic disturbances and UCS) upstream and downstream of the shock. We show that the asymptotic energy distribution of the particles accelerated by DSA/TR has very similar characteristics with the one due to DSA alone, but the synergy of DSA with TR is much more efficient: The acceleration time is an order of magnitude shorter and the maximum energy reached two orders of magnitude higher. We claim that DSA is the dominant acceleration mechanism in a short period before TR is established, and then strong turbulence will dominate the heating and acceleration of the particles. In other words, the shock serves as the mechanism to set up a strongly turbulent environment, in which the acceleration mechanism will ultimately be the synergy of DSA and TR.

  6. Diffusion-synthetic acceleration methods for discrete-ordinates problems

    International Nuclear Information System (INIS)

    Larsen, E.W.

    1984-01-01

    The diffusion-synthetic acceleration (DSA) method is an iterative procedure for obtaining numerical solutions of discrete-ordinates problems. The DSA method is operationally more complicated than the standard source-iteration (SI) method, but if encoded properly it converges much more rapidly, especially for problems with diffusion-like regions. In this article we describe the basic ideas behind the DSA method and give a (roughly chronological) review of its long development. We conclude with a discussion which covers additional topics, including some remaining open problems an the status of current efforts aimed at solving these problems

  7. Diffusion-synthetic acceleration methods for the discrete-ordinates equations

    International Nuclear Information System (INIS)

    Larsen, E.W.

    1983-01-01

    The diffusion-synthetic acceleration (DSA) method is an iterative procedure for obtaining numerical solutions of discrete-ordinates problems. The DSA method is operationally more complicated than the standard source-iteration (SI) method, but if encoded properly it converges much more rapidly, especially for problems with diffusion-like regions. In this article we describe the basic ideas beind the DSA method and give a (roughly chronological) review of its long development. We conclude with a discussion which covers additional topics, including some remaining open problems and the status of current efforts aimed at solving these problems

  8. DSA for Secured Optical Communication

    International Nuclear Information System (INIS)

    Shojaei, A.A.; Amiri, I.S.

    2011-01-01

    Novel system of dark soliton array (DSA) for secured communication is proposed. The DSA are obtained by using a series micro ring resonators where the input wavelengths of λ 1 = 1516 nm, λ 2 = 1518 nm and λ 3 =1520 nm propagate inside the system and finally will be multiplexed. For security applications, the DSA can be tuned and amplified. The use of DSA for high capacity can be realized by using proposed secured system. (author)

  9. DSA diagnosis and interventional management of postoperative bleeding

    International Nuclear Information System (INIS)

    Li Yuwei; Zhang Fuqiang; Li Yunhui; Yuan Liang; Si Guangyan; Liu Lili

    2009-01-01

    Objective: To discuss the clinical application of DSA and interventional management in diagnosing and treating the bleeding after surgery. Methods: The clinical data and the interventional management of 14 patients with DSA-proved postoperative bleeding, encountered during the period of Aug. 2005-Jan. 2008, were retrospectively analyzed. The surgeries included subtotal gastrectomy (n=4), pancreatoduodenectomy (n=3), cesarean section (n=2), nephrolithotomy (n=3), heminephrectomy (n=1), internal hemorrhoidectomy (n=1). Results: Seventeen arterial bleeding sites were demonstrated, including gastroduodenal (n=2), left gastric (n=4), phrenic (n=1), short gastric (n=1), superior mesenteric (n=2), renal (n=4), uterine (n=2) and internal pudendal (n=1) artery. The diagnosis was confirmed with DSA in all 14 patients, of which embolization was successfully carried out in 13 in one session (92.8%). The remaining one case had to be operated again to stop the bleeding because of the failure of the superselective catheterization. No serious complications, such as organ necrosis or visceral dysfunction, occurred. Conclusion: As a safe, minimally-invasive and effective technique, DSA and interventional management are very helpful in diagnosing and treating the bleeding after surgery. (authors)

  10. Digital subtaction angiography (DSA) in renal-related conditions

    International Nuclear Information System (INIS)

    Kim, Dae Ho; Jeong, Seong Wook; Bae, Kwang Soo; Chung, Moo Chan; Kim, Ki Jeong

    1986-01-01

    DSA (Digital Subtraction Angiography) is a valuable diagnostic imaging method in many clinical fields, including renal-related conditions. Sixty four renal DSA examination were performed in 59 patients with renal-related diseases from Jan. 1984 to Dec. 1985. Summary of These were as follows: 1. Intraarterial(IA)-DSA is performed in 6 cases, intravenous(IV)-DSA in 58 cases. In 58 Examinations of IV-DSA, diagnostic image quality is obtained in 51 cases (88%). 2. In investigations of a possible renovascular etiology of hypertension, IV-DSA is a simple, safe, sensitive and accurate method. On screening for evaluation of renovascular hypertension, RSP should be replaced with IV-DSA, because IV-DSA is more sensitive and accurate and can detect not only anatomic change of renal artery but also functional hemodynamic change. 3. IV-DSA is valuable in diseases with morphologic changes of vessels. In characterization of a known renal mass, and evaluation of hematuria, suspected aneurysm and renal trauma, IV-DSA is very useful diagnostic imaging modality. 4. In evaluation of potential renal donors, IV-DSA is an accurate and safe method with 82.4% of accuracy. IV-DSA also is useful in follow-up of allograft recipients. 5. In investigation of diabetic nephropathy, glomerulonephritis, pyelonephritis, IV-DSA is little helpful. 6. The advantages of DSA are well known, particularly post-procedure process using computer program is helpful for obtaining information's of hemodynamic change or time-suquence-curve of density etc. More technical improvement with this modality is required for improvement of the image quality and resolution. And more accumulation of clinical experience is required in order to increase the diagnostic accuracy.

  11. Digital subtaction angiography (DSA) in renal-related conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Jeong, Seong Wook; Bae, Kwang Soo; Chung, Moo Chan; Kim, Ki Jeong [Soon Chun Hyang University College of Medicine, Asan (Korea, Republic of)

    1986-10-15

    DSA (Digital Subtraction Angiography) is a valuable diagnostic imaging method in many clinical fields, including renal-related conditions. Sixty four renal DSA examination were performed in 59 patients with renal-related diseases from Jan. 1984 to Dec. 1985. Summary of These were as follows: 1. Intraarterial(IA)-DSA is performed in 6 cases, intravenous(IV)-DSA in 58 cases. In 58 Examinations of IV-DSA, diagnostic image quality is obtained in 51 cases (88%). 2. In investigations of a possible renovascular etiology of hypertension, IV-DSA is a simple, safe, sensitive and accurate method. On screening for evaluation of renovascular hypertension, RSP should be replaced with IV-DSA, because IV-DSA is more sensitive and accurate and can detect not only anatomic change of renal artery but also functional hemodynamic change. 3. IV-DSA is valuable in diseases with morphologic changes of vessels. In characterization of a known renal mass, and evaluation of hematuria, suspected aneurysm and renal trauma, IV-DSA is very useful diagnostic imaging modality. 4. In evaluation of potential renal donors, IV-DSA is an accurate and safe method with 82.4% of accuracy. IV-DSA also is useful in follow-up of allograft recipients. 5. In investigation of diabetic nephropathy, glomerulonephritis, pyelonephritis, IV-DSA is little helpful. 6. The advantages of DSA are well known, particularly post-procedure process using computer program is helpful for obtaining information's of hemodynamic change or time-suquence-curve of density etc. More technical improvement with this modality is required for improvement of the image quality and resolution. And more accumulation of clinical experience is required in order to increase the diagnostic accuracy.

  12. Adjusting the displaced tip of peripherally inserted central catheter under DSA guidance

    International Nuclear Information System (INIS)

    Mao Yanjun; Dong Huijuan; Zhang Lingjuan; Li Hongmei; Xu Lianqin

    2009-01-01

    Objective: To explore a new method to adjust the displaced tip of peripherally inserted central catheter (PICC) under DSA guidance. Methods: Under DSA guidance, the displaced tip of PICC was repositioned to the ideal junction area of superior vena cava with right atrium with proper manipulation. Results: Under DSA guidance, the displaced tip of PICC was successfully corrected in 13 cases. The mean operative time was 15.53 minutes, which was markedly shorter than that needed by blind adjusting beside the bed. Conclusion: The displacement of PICC tip is a common occurrence, which is hard to be avoided. Under DSA guidance, the adjusting manipulation of the displaced PICC tip is safe and time-saving with high successful rate. It is worth popularizing this technique in clinical practice. (authors)

  13. The comparison of aneurysmal necks measured on three dimensional reconstruction images of rotational DSA and those of traditional DSA

    International Nuclear Information System (INIS)

    Wu Chunhong; Chen Zuoquan; Gu Binxian; Zhang Guiyun

    2006-01-01

    Objective: To evaluate the value of three dimensional reconstruction images of rotational DSA on measuring aneurysmal necks and make a comparison with traditional DSA so as to provide more abundant and accurate information for the embolization of aneurysm. Methods: A comparison was made between the measurement of aneurismal necks from 14 cases with traditional DSA examination and a measurement made on three dimensional reconstruction images of the same patients. Results: There was a difference shown in the measurement of the aneurysmal necks between three dimensional reconstruction images of rotational DSA and those of traditional DSA, outcoming with more angles and data on three dimensional reconstruction images. Conclusions: There are more angles of aneurysmal neck can be shown on rotational 3D DSA especially for the demonstration of the largest aneurysmal neck with a directional value for the intervention. (authors)

  14. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  15. Just in Time DSA-The Hanford Nuclear Safety Basis Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Olinger, S. J.; Buhl, A. R.

    2002-02-26

    The U.S. Department of Energy, Richland Operations Office (RL) is responsible for 30 hazard category 2 and 3 nuclear facilities that are operated by its prime contractors, Fluor Hanford Incorporated (FHI), Bechtel Hanford, Incorporated (BHI) and Pacific Northwest National Laboratory (PNNL). The publication of Title 10, Code of Federal Regulations, Part 830, Subpart B, Safety Basis Requirements (the Rule) in January 2001 imposed the requirement that the Documented Safety Analyses (DSA) for these facilities be reviewed against the requirements of the Rule. Those DSA that do not meet the requirements must either be upgraded to satisfy the Rule, or an exemption must be obtained. RL and its prime contractors have developed a Nuclear Safety Strategy that provides a comprehensive approach for supporting RL's efforts to meet its long term objectives for hazard category 2 and 3 facilities while also meeting the requirements of the Rule. This approach will result in a reduction of the total number of safety basis documents that must be developed and maintained to support the remaining mission and closure of the Hanford Site and ensure that the documentation that must be developed will support: compliance with the Rule; a ''Just-In-Time'' approach to development of Rule-compliant safety bases supported by temporary exemptions; and consolidation of safety basis documents that support multiple facilities with a common mission (e.g. decontamination, decommissioning and demolition [DD&D], waste management, surveillance and maintenance). This strategy provides a clear path to transition the safety bases for the various Hanford facilities from support of operation and stabilization missions through DD&D to accelerate closure. This ''Just-In-Time'' Strategy can also be tailored for other DOE Sites, creating the potential for large cost savings and schedule reductions throughout the DOE complex.

  16. Just in Time DSA-The Hanford Nuclear Safety Basis Strategy

    International Nuclear Information System (INIS)

    Olinger, S. J.; Buhl, A. R.

    2002-01-01

    The U.S. Department of Energy, Richland Operations Office (RL) is responsible for 30 hazard category 2 and 3 nuclear facilities that are operated by its prime contractors, Fluor Hanford Incorporated (FHI), Bechtel Hanford, Incorporated (BHI) and Pacific Northwest National Laboratory (PNNL). The publication of Title 10, Code of Federal Regulations, Part 830, Subpart B, Safety Basis Requirements (the Rule) in January 2001 imposed the requirement that the Documented Safety Analyses (DSA) for these facilities be reviewed against the requirements of the Rule. Those DSA that do not meet the requirements must either be upgraded to satisfy the Rule, or an exemption must be obtained. RL and its prime contractors have developed a Nuclear Safety Strategy that provides a comprehensive approach for supporting RL's efforts to meet its long term objectives for hazard category 2 and 3 facilities while also meeting the requirements of the Rule. This approach will result in a reduction of the total number of safety basis documents that must be developed and maintained to support the remaining mission and closure of the Hanford Site and ensure that the documentation that must be developed will support: compliance with the Rule; a ''Just-In-Time'' approach to development of Rule-compliant safety bases supported by temporary exemptions; and consolidation of safety basis documents that support multiple facilities with a common mission (e.g. decontamination, decommissioning and demolition [DD and D], waste management, surveillance and maintenance). This strategy provides a clear path to transition the safety bases for the various Hanford facilities from support of operation and stabilization missions through DD and D to accelerate closure. This ''Just-In-Time'' Strategy can also be tailored for other DOE Sites, creating the potential for large cost savings and schedule reductions throughout the DOE complex

  17. Clinical usefulness of stereoscopic DSA

    International Nuclear Information System (INIS)

    Bussaka, Hiromasa; Takahashi, Mutsumasa; Miyawaki, Masayuki; Korogi, Yukinori; Yamashita, Yasuyuki; Izunaga, Hiroshi; Nakashima, Koki; Yoshizumi, Kazuhiro

    1988-01-01

    Digital subtraction angiography (DSA) is widely used as a screening examination for vascular diseases, but it has several disadvantages, one of which is overlapping of the vessels. To overcome this disadvantage, stereoscopic technique is applied to our DSA equipment. Stereoscopic DSA is obtained by alternate exposures from twin focal spots of an x-ray tube without additional contrast medium or radiation exposures. Stereoscopic intravenous DSA was performed 223 times, and was useful in 157 times (70.4 %) for the identification and stereoscopic observation of the abdominal and pelvic vessels. Thirty-seven intra-arterial DSAs were performed stereoscopically for cranial, abdominal and pelvic angiograms, and effective studies were obtained in 30 DSAs (81.1 %) with demonstration of tumor stains and displacement of the vessels. It is necessary to use adequate compensation filters for the good stereoscopic DSAs, especially for the cervical and thoracic DSAs. (author)

  18. DSA patterning options for logics and memory applications

    Science.gov (United States)

    Liu, Chi-Chun; Franke, Elliott; Mignot, Yann; LeFevre, Scott; Sieg, Stuart; Chi, Cheng; Meli, Luciana; Parnell, Doni; Schmidt, Kristin; Sanchez, Martha; Singh, Lovejeet; Furukawa, Tsuyoshi; Seshadri, Indira; De Silva, Ekmini Anuja; Tsai, Hsinyu; Lai, Kafai; Truong, Hoa; Farrell, Richard; Bruce, Robert; Somervell, Mark; Sanders, Daniel; Felix, Nelson; Arnold, John; Hetzer, David; Ko, Akiteru; Metz, Andrew; Colburn, Matthew; Corliss, Daniel

    2017-03-01

    The progress of three potential DSA applications, i.e. fin formation, via shrink, and pillars, were reviewed in this paper. For fin application, in addition to pattern quality, other important considerations such as customization and design flexibility were discussed. An electrical viachain study verified the DSA rectification effect on CD distribution by showing a tighter current distribution compared to that derived from the guiding pattern direct transfer without using DSA. Finally, a structural demonstration of pillar formation highlights the importance of pattern transfer in retaining both the CD and local CDU improvement from DSA. The learning from these three case studies can provide perspectives that may not have been considered thoroughly in the past. By including more important elements during DSA process development, the DSA maturity can be further advanced and move DSA closer to HVM adoption.

  19. Carbon dioxide hepatic arterial DSA and CT angiography in swine model

    International Nuclear Information System (INIS)

    Tan Huaqiao; Hu Hongjie; Huang Wenxin; Zhang Shizheng; Dong Yonghua; Zhou Dachun

    2005-01-01

    Objective: To evaluate the imaging findings of carbon dioxide hepatic arterial DSA and CT angiography in normal swine. Methods: In general anaesthesia, hepatic arterial DSA was performed with 10 ml iodinated contrast medium (5 ml/s, 10 ml) in 5 normal swine, and then repeated hepatic arterial CO 2 -DSA was performed with a total of 30-50 ml CO 2 injected by manually operated syringe at the velocity of 5-8 ml/s, followed by CO 2 -CT angiography. All the swine were sacrificed after the procedure, the selective hepatic segments were removed, and pathological examination was carried out. The radiological features of hepatic arterial DSA with iodinated contrast medium and CO 2 and CT angiography with CO 2 were analyzed. The ability of showing the arterio-venous shunt was compared. Results: Hepatic arterio-portal shunt was found in the advanced arterial phase of CO 2 -DSA in three of five swine, which was furthermore demonstrated by CO 2 -CT angiography, but iodinated contrast medium DSA showed no arterio-portal shunt in all swine. The gaseous CO 2 in portal vein was absorbed within 1-3 minutes. No CO 2 shunted into the hepatic vein during CO 2 -DSA and CO 2 -CTA. Histology didn't reveal any abnormal changes caused by CO 2 shunt in the swine liver. Conclusion: (1) Hepatic arterial CO 2 -DSA and CO 2 -CTA can reveal arterio-portal shunt that isn't seen with iodinated contrast medium, the gaseous CO 2 in portal vein was absorbed within 1-3 minutes. (2) The gaseous CO 2 can't shunt into hepatic vein when the hepatic artery is perfused with CO 2 in normal swine. (authors)

  20. Efficacy of balloon temporary occlusion and intraoperative DSA in surgically difficult aneurysm

    International Nuclear Information System (INIS)

    Ezura, Masayuki; Mizoi, Kazuo; Yoshimoto, Takashi; Takahashi, Akira.

    1993-01-01

    A digital subtraction angiographic (DSA) apparatus has been installed in one of our operating rooms since April 1987. We performed intraoperative DSA in 42 aneurysmal surgeries in 38 patients and balloon temporary occlusion in 33 surgeries. The aneurysm was on an internal carotid artery in 26 cases and on the vertebro-basilar system in 16. A heparin-coated catheter (Anthron, Toray, Tokyo), 6 french in diameter, was inserted transfemorally and was put in a parent artery under general anesthesia. A balloon was temporarily inflated to determine inflation volume. The balloon catheter was soon deflated and was drawn back into the introducing catheter to avoid developing microembolus. The patients were not systemically heparinized but the introducing catheters were slowly flushed with heparinized saline during operation. Then a craniotomy was carried out. Next DSA was performed when temporary occlusion or confirmation of clipping was necessary. In cases of balloon temporary occlusion, the operating field was not obstructed as it is when a temporary clip is used, despite adequate flow reduction of the parent artery. After DSA for confirmation of clipping adjustment of it was performed in 12 cases out of 42. No complications occurred due to use of an introducing or a balloon catheter. We conclude that combined intravascular and neurosurgical approach, particularly for the large aneurysms with the difficulty of proximal control, can be a useful method of treatment. (author)

  1. Electron Acceleration in Supernovae and Millimeter Perspectives

    Directory of Open Access Journals (Sweden)

    Keiichi Maeda

    2014-12-01

    Full Text Available Supernovae launch a strong shock wave by the interaction of the expanding ejecta and surrounding circumstellar matter (CSM. At the shock, electrons are accelerated to relativistic speed, creating observed synchrotron emissions in radio wavelengths. In this paper, I suggest that SNe (i.e., < 1 year since the explosion provide a unique site to study the electron acceleration mechanism. I argue that the eciency of the acceleration at the young SN shock is much lower than conventionally assumed, and that the electrons emitting in the cm wavelengths are not fully in the Diffusive Shock Acceleration (DSA regime. Thus radio emissions from young SNe record information on the yet-unresolved 'injection' mechanism. I also present perspectives of millimeter (mm observations of SNe - this will provide opportunities to uniquely determine the shock physics and the acceleration efficiency, to test the non-linear DSA mechanism and provide a characteristic electron energy scale with which the DSA start dominating the electron acceleration.

  2. Evaluation of DSA test phantoms commercially available in the UK

    International Nuclear Information System (INIS)

    Cowen, A.R.; Coleman, N.J.; HArtley, P.J.

    1985-01-01

    Several digital subtraction angiography systems have been installed in the United Kingdom. Many others will no doubt be installed over the next few years. Given the high cost and technical complexity of DSA systems it is natural that the purchasers of such equipment should be concerned that their machine has been adjusted correctly prior to clinical acceptance and continues to operate satisfactorily thereafter. In response to these concerns several companies in the U.K. are now selling DSA test phantoms. All DSA phantoms which are currently commercially available are manufactured in the U.S.A. Im order to assess the effectiveness of these phantoms the DHSS has initiated the assessment project described here. The findings are tabulated . Performance is indicated by a star rating system, based on the opinions of two X-ray engineers and one medical physicist. (author)

  3. Synthetic acceleration methods for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.; Larsen, E.W.

    1992-01-01

    The diffusion synthetic acceleration (DSA) algorithm effectively accelerates the iterative solution of transport problems with isotropic or mildly anisotropic scattering. However, DSA loses its effectiveness for transport problems that have strongly anisotropic scattering. Two generalizations of DSA are proposed, which, for highly anisotropic scattering problems, converge at least an order of magnitude (clock time) faster than the DSA method. These two methods are developed, the results of Fourier analysis that theoretically predict their efficiency are described, and numerical results that verify the theoretical predictions are presented. (author). 10 refs., 7 figs., 5 tabs

  4. Synthetic acceleration methods for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.; Larsen, E.W.

    1991-01-01

    This paper reports on the diffusion synthetic acceleration (DSA) algorithm that effectively accelerates the iterative solution of transport problems with isotropic or mildly anisotropic scattering. However, DSA loses its effectiveness for transport problems that have strongly anisotropic scattering. Two generalizations of DSA are proposed, which, for highly anisotropic scattering problems, converge at least an order of magnitude (clock time) faster than the DSA method. These two methods are developed, the results of Fourier analyses that theoretically predict their efficiency are described, and numerical results that verify the theoretical predictions are presented

  5. Incorporating DSA in multipatterning semiconductor manufacturing technologies

    Science.gov (United States)

    Badr, Yasmine; Torres, J. A.; Ma, Yuansheng; Mitra, Joydeep; Gupta, Puneet

    2015-03-01

    Multi-patterning (MP) is the process of record for many sub-10nm process technologies. The drive to higher densities has required the use of double and triple patterning for several layers; but this increases the cost of the new processes especially for low volume products in which the mask set is a large percentage of the total cost. For that reason there has been a strong incentive to develop technologies like Directed Self Assembly (DSA), EUV or E-beam direct write to reduce the total number of masks needed in a new technology node. Because of the nature of the technology, DSA cylinder graphoepitaxy only allows single-size holes in a single patterning approach. However, by integrating DSA and MP into a hybrid DSA-MP process, it is possible to come up with decomposition approaches that increase the design flexibility, allowing different size holes or bar structures by independently changing the process for every patterning step. A simple approach to integrate multi-patterning with DSA is to perform DSA grouping and MP decomposition in sequence whether it is: grouping-then-decomposition or decomposition-then-grouping; and each of the two sequences has its pros and cons. However, this paper describes why these intuitive approaches do not produce results of acceptable quality from the point of view of design compliance and we highlight the need for custom DSA-aware MP algorithms.

  6. Study of DSA-guided percutaneous puncture location of foramen oval

    International Nuclear Information System (INIS)

    Zhao Xiaojun; He Jiawei; Bai Guanghui; Shi Jianjing; Xu Chongyong; Zhan Gonghao

    2008-01-01

    Objective: To study the technique of digital substraction angiography (DSA)-guided percutaneous puncture location of foramen oval. Methods: 39 cases of trigeminal neuralgia were included in the study from Feb. 2004 to Oct. 2006. The patients were punctured by the amending anterior position. The f0ramen oval was displayed by moving the tube tilted 20-28 degree to the caudal and 16-23 degree to the healthy side. The direction and depth of the needles was determined on the lateral view. Then, radio-frequency thermocoagulation therapy was performed. Results: The needles were located in oval foramen in all the patients. Pain disappeared in 36 cases, alleviated in other cases, and no serious complication occurred during therapy. Conclusions: Oval foramen locations by DSA can improve the successful rate of operation. The foramen oval can be clearly displayed by DSA-guided in amending position, with comfortable position for patients. (authors)

  7. N7 logic via patterning using templated DSA: implementation aspects

    Science.gov (United States)

    Bekaert, J.; Doise, J.; Gronheid, R.; Ryckaert, J.; Vandenberghe, G.; Fenger, G.; Her, Y. J.; Cao, Y.

    2015-07-01

    In recent years, major advancements have been made in the directed self-assembly (DSA) of block copolymers (BCP). Insertion of DSA for IC fabrication is seriously considered for the 7 nm node. At this node the DSA technology could alleviate costs for multiple patterning and limit the number of masks that would be required per layer. At imec, multiple approaches for inserting DSA into the 7 nm node are considered. One of the most straightforward approaches for implementation would be for via patterning through templated DSA; a grapho-epitaxy flow using cylindrical phase BCP material resulting in contact hole multiplication within a litho-defined pre-pattern. To be implemented for 7 nm node via patterning, not only the appropriate process flow needs to be available, but also DSA-aware mask decomposition is required. In this paper, several aspects of the imec approach for implementing templated DSA will be discussed, including experimental demonstration of density effect mitigation, DSA hole pattern transfer and double DSA patterning, creation of a compact DSA model. Using an actual 7 nm node logic layout, we derive DSA-friendly design rules in a logical way from a lithographer's view point. A concrete assessment is provided on how DSA-friendly design could potentially reduce the number of Via masks for a place-and-routed N7 logic pattern.

  8. Improvement of DSA, reduction of acquisition images and suppression of halation

    International Nuclear Information System (INIS)

    Yamada, Kinichi; Kaga, Yuji; Eguchi, Yoichi; Kinai, Shigeo; Asahina, Hiroshi; Fujita, Hitoshi; Ogura, Ichiro; Yasuhara, Hiroshi.

    1991-01-01

    Recently, digital subtraction angiography (DSA) is seeing widespread use. Especially, intraarterial DSA (IA-DSA) makes good use of interventional radiology. However, we know that the skin dose for DSA is so much larger than general angiography, and halations often appearing on DSA images. In this report, we show two improvements of DSA. First, the skin dose for DSA is successfully decreased to one-sixth compared with the late DSA of cerebral artery by a reduction in acquisition images. Secondly, we are doing well in suppressing halation by exchanging the control point of automatic exposure control (AEC) from one-half to one-fourth. (author)

  9. Three-dimensional image reconstruction from stereo DSA

    International Nuclear Information System (INIS)

    Sakamoto, Kiyoshi; Kotoura, Noriko; Umehara, Takayoshi; Yamada, Eiji; Inaba, Tomohiro; Itou, Hiroshi

    1999-01-01

    The technique of interventional radiology has spread rapidly in recent years, and three-dimensional information from blood vessel images is being sought to enhance examinations. Stereo digital subtraction angiography (DSA) and rotational DSA were developed for that purpose. However, it is difficult with stereo DSA to observe the image pair during examination and to obtain positional information on blood vessels. Further, the exposure dose is increased in rotational DSA when many mask images need to be collected, and the patient is required to hold his or her breath for a long duration. We therefore devised a technique to construct three-dimensional blood vessel images by employing geometrical information extracted from stereo DSA images using the right and left images. We used a judgment method based on the correlation coefficient, although we had to extract an equal blood vessel from the right and left images to determine the three-dimensional coordinates of the blood vessel. The reconstructed three-dimensional blood vessels were projected from various angles, again by using a virtual focus, and new images were created. These image groups were displayed as rotational images by the animation display function incorporated in the DSA device. This system can observe blood vessel images of the same phase at a free angle, although the image quality is inferior to that of rotational DSA. In addition, because collection of the mask images is reduced, exposure dose can be decreased. Further, the system offers enhanced safety because no mechanical movement of the imaging system is involved. (author)

  10. The clinical value of the special functions of DSA in interventional embolization for uterine fibroids

    International Nuclear Information System (INIS)

    He Yushen; Lu Dong; Lv Weifu; Zhang Jingsong

    2009-01-01

    Objective: To evaluate the special functions of DSA in interventional embolization therapy for uterine fibroids. Methods: The special functions of DSA, including 3D-DSA, the optimal working position and road-mapping technique, were utilized in performing interventional embolization therapy for uterine fibroids in twenty-six cases (experimental group). Routine DSA angiography was employed in twenty cases(control group). The volume of contrast media used, the time of completing the interventional procedure and the total fluoroscopic time in two groups were compared and the results were analyzed. Results: The difference in the volume of contrast agent used and in the total fluoroscopic time between two groups was statistically significant (P 0.05). Conclusion: In treating uterine fibroids with interventional embolization, the use of the special functions of DSA can reduce the manipulation time and lower the operation risk. Moreover, the technique of visible 3D reconstruction image is of great significance in guiding the procedure. (authors)

  11. Prediction of tumor-brain adhesion in intracranial meningiomas by MR imaging and DSA

    International Nuclear Information System (INIS)

    Takeguchi, Takashi; Miki, Hitoshi; Shimizu, Teruhiko; Kikuchi, Keiichi; Mochizuki, Teruhito; Ohue, Shiro; Ohnishi, Takanori

    2003-01-01

    The purpose of this study was to evaluate the usefulness of MRI (magnetic resonance imaging) and DSA (digital subtraction angiography) by using preoperative MRI and DSA findings in the examination of meningiomas before excision. In particular, we focused on their usefulness in predicting tumor-brain adhesion during surgery. The subjects were 36 patients with intracranial meningioma who underwent tumor excision at which time neurosurgeons examined the tumor-brain adhesion. Two neurosurgeons evaluated the degree of tumor-brain adhesion from operation records and videotapes recorded during surgery. Two neuroradiologists retrospectively evaluated the preoperative MRI findings including tumor diameter, signal intensity of the tumor parenchyma obtained with T 2 -weighted imaging (T 2 WI), characteristics of the tumor-brain interface, and degree of peritumoral brain edema. The vascular supply was also evaluated from the preoperative DSA findings. The relationship between these MRI and DSA findings and the degree of tumor-brain adhesion during surgery as classified by the neurosurgeons was statistically analyzed. The degree of peritumoral brain edema and the shapes and characteristics of the tumor-brain interface, including the findings of FLAIR (fluid-attenuated inversion recovery) imaging and vascular supply observed by DSA, were significantly correlated with tumor-brain adhesion. In particular, the shapes and characteristics of the tumor-brain interface as observed by T 1 -weighted imaging (T 1 WI), T2WI, and FLAIR, respectively, as well as the vascular supply observed by DSA, were closely correlated with the degree of tumor-brain adhesion encountered during surgery. According to these results, we developed a method of predicting tumor-brain adhesion that considers the shape of the tumor-brain interface revealed by MRI and the vascular supply revealed by DSA. We retrospectively examined the findings of MRI and DSA performed before excision of meningioma and clarified

  12. S2 synthetic acceleration scheme for the one-dimensional S/sub n/ equations

    International Nuclear Information System (INIS)

    Lorence, L.J. Jr.; Larsen, E.W.; Morel, J.E.

    1986-01-01

    The authors have developed an S 2 synthetic acceleration method for the one-dimensional S/sub n/ equations with linear-discontinuous (LD) spatial differencing, and implemented it in a new version of the ONETRAN code. As in the diffusion-synthetic acceleration (DSA) of Morel, both the zeroth and first moments of the scattering source are accelerated. This is done by using the S 2 equations with Gauss quadrature rather than the diffusion equation as the low-order operator in the synthetic acceleration scheme

  13. Synthetic acceleration methods for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.

    1989-01-01

    One of the iterative methods which is used to solve the discretized transport equation is called the Source Iteration Method (SI). The SI method converges very slowly for problems with optically thick regions and scattering ratios (σ s /σ t ) near unity. The Diffusion-Synthetic Acceleration method (DSA) is one of the methods which has been devised to improve the convergence rate of the SI method. The DSA method is a good tool to accelerate the SI method, if the particle which is being dealt with is a neutron. This is because the scattering process for neutrons is not severely anisotropic. However, if the particle is a charged particle (electron), DSA becomes ineffective as an acceleration device because here the scattering process is severely anisotropic. To improve the DSA algorithm for electron transport, the author approaches the problem in two different ways in this thesis. He develops the first approach by accelerating more angular moments (φ 0 , φ 1 , φ 2 , φ 3 ,...) than is done in DSA; he calls this approach the Modified P N Synthetic Acceleration (MPSA) method. In the second approach he modifies the definition of the transport sweep, using the physics of the scattering; he calls this approach the Modified Diffusion Synthetic Acceleration (MDSA) method. In general, he has developed, analyzed, and implemented the MPSA and MDSA methods in this thesis and has shown that for a high order quadrature set and mesh widths about 1.0 cm, they are each about 34 times faster (clock time) than the DSA method. Also, he has found that the MDSA spectral radius decreases as the mesh size increases. This makes the MDSA method a better choice for large spatial meshes

  14. Hepatic VX2 tumor after portal vein occlusion in rabbits: evaluation with DSA

    International Nuclear Information System (INIS)

    Qi Yueyong; Zou Liguang; Dai Shuhua; Zhang Qichuan; Chen Lin; Huang Xiaobing; Huan Guangqiang

    2006-01-01

    Objective: To study the value of DSA for hepatic vascular anatomy, and to evaluate the efficacy of portal vein occlusion in rabbits with hepatic VX2 tumor. Methods: Twenty New Zealand white rabbits were randomly divided into two groups with 10 in each group, including test group A and positive control group B of ham operation. For the test group A, portal branch ligation (PBL) was performed for the left external branch after 3 weeks of the tumor implantation to the left external lobe. Two weeks later, the DSA of hepatic artery and portal vein were performed in all of the rabbits. Results: The total displaying effectiveness of the branches of hepatic artery by DSA was better than that by vascular perfusion. There was hypovascular blood supply to hepatic artery implantation of the tumor in the test group A, comparing with that of the group B. Conclusion: DSA can clearly display special details of the hepatic vascular anatomy in rabbits, and play an important role in post-procedural evaluation of the portal vein occlusion in rabbits. (authors)

  15. Dynamic study of DSA by video-densitometry

    International Nuclear Information System (INIS)

    Imamura, Keiko; Tsukamoto, Hiroshi; Ashida, Hiroshi; Ishikawa, Tohru; Fujii, Masamichi; Uji, Teruyuki

    1985-01-01

    A system was developed for the dynamic study of DSA by video-densitometric technique. As subtraction images are stored to VTR in our DSA examinations, a frame counter was designed to select images on VTR at an arbitrary interval. ROI setting and video-densitometry were performed using a TV image processor and its host computer. Images were sampled at the rate of 3 frames per second, and clear time-density curves were obtained from brain DSA examinations. Although it takes about 30 minutes to analyse one examination, it is also possible to analyse previous data stored on VTR. For DSA systems having no additional digital storage unit, this method will be helpful. Reduction in image quality through VTR storage had no problem in video-densitometry. Phantom studies have been made concerning the temporal variation of the image brightness during the 20 second-exposure and also the effect of the subjects thickness on the contrast. Filtering for low-grade averaging is preferable for dynamic studies. (author)

  16. Development of simple DSA equipment and experience of its using

    International Nuclear Information System (INIS)

    Yoshino, Fumiki; Matsuo, Michimasa.

    1984-01-01

    We manufactured a cheap and portable simple DSA equipment, consisting of an ordinary X-ray system and a microcomputer which is the hardware exclusively used for real-time processing. As the result of the basic clinical examination by simple DSA equipment, we found it effective on the follow-up study of diseases such as the arteriosclerosis obliterans. We performed the intra-arterial DSA with a catheter which was small in the inside diameter, to reduce its aggression, and at the same time we are trying its application to the functional image. In the future, it will show us the possibility of the routine screening examination at an out-patients' department. Compared with DSA equipment sold in the market, our simple DSA equipment is good enough to make diagnostic images in spite of the limited capacity of TV system. Moreover, our DSA equipment is cheap and portable, and is very effective for the follow-up study of diseases such as the arteriosclerosis obliterans. So we can say that simple DSA equipment is of excellent clinical value. (author)

  17. Coarse mesh and one-cell block inversion based diffusion synthetic acceleration

    Science.gov (United States)

    Kim, Kang-Seog

    DSA (Diffusion Synthetic Acceleration) has been developed to accelerate the SN transport iteration. We have developed solution techniques for the diffusion equations of FLBLD (Fully Lumped Bilinear Discontinuous), SCB (Simple Comer Balance) and UCB (Upstream Corner Balance) modified 4-step DSA in x-y geometry. Our first multi-level method includes a block Gauss-Seidel iteration for the discontinuous diffusion equation, uses the continuous diffusion equation derived from the asymptotic analysis, and avoids void cell calculation. We implemented this multi-level procedure and performed model problem calculations. The results showed that the FLBLD, SCB and UCB modified 4-step DSA schemes with this multi-level technique are unconditionally stable and rapidly convergent. We suggested a simplified multi-level technique for FLBLD, SCB and UCB modified 4-step DSA. This new procedure does not include iterations on the diffusion calculation or the residual calculation. Fourier analysis results showed that this new procedure was as rapidly convergent as conventional modified 4-step DSA. We developed new DSA procedures coupled with 1-CI (Cell Block Inversion) transport which can be easily parallelized. We showed that 1-CI based DSA schemes preceded by SI (Source Iteration) are efficient and rapidly convergent for LD (Linear Discontinuous) and LLD (Lumped Linear Discontinuous) in slab geometry and for BLD (Bilinear Discontinuous) and FLBLD in x-y geometry. For 1-CI based DSA without SI in slab geometry, the results showed that this procedure is very efficient and effective for all cases. We also showed that 1-CI based DSA in x-y geometry was not effective for thin mesh spacings, but is effective and rapidly convergent for intermediate and thick mesh spacings. We demonstrated that the diffusion equation discretized on a coarse mesh could be employed to accelerate the transport equation. Our results showed that coarse mesh DSA is unconditionally stable and is as rapidly convergent

  18. Digital substraction angiography (DSA) in a universal radiodiagnostic room with a novel multi-pulse high-frequency generator

    International Nuclear Information System (INIS)

    Ellegast, H.H.; Kloss, R.; Mayr, H.; Ammann, E.; Kuehnel, W.; Siemens A.G., Erlangen

    1985-01-01

    Application of digital subtraction angiography in a universal radiodiagnostic room can be implemented rapidly and reliably. The number of examinations could be increased without negative effects to conventional operations in this room. At optimum radiation hygiene and high-degree operational safety, the multipulse high-frequency generator with its DSA parameter automatic system guarantees a reproducibly good image quality equalling that of a special DSA facility. In this way, the examination room constitutes an economic solution for small-sized hospitals without any special angiography room, too. (orig.) [de

  19. The operative cooperation and nursing in performing airway stent placement under DSA guidance for treating airway stenosis

    International Nuclear Information System (INIS)

    Yan Baojun; Wu Gang; Han Xinwei; Wang Nan; Shi Jin; Si Wenfeng; Wang Kai; Su Ning; Liu Jia; Hai Dandan

    2011-01-01

    Objective: To discuss the key points of the nursing care for effectively performing airway stent placement under DSA monitoring for airway stenosis. Methods: Corresponding nursing care measures were carried out for 118 patients with airway stenosis who were treated with airway stent placement. Results: The symptom of dyspnea was markedly relieved after stent implantation in all 118 patients with airway stenosis. Conclusion: To strengthen the preoperative psychological nursing and operative posture training, to make close postoperative watch on vital signs, to adopt some prevention measures for possible complications and to give necessary medical advises at the time of discharge are very helpful for patient's recovery after the surgery. (authors)

  20. Real-world experimentation of distributed DSA network algorithms

    DEFF Research Database (Denmark)

    Tonelli, Oscar; Berardinelli, Gilberto; Tavares, Fernando Menezes Leitão

    2013-01-01

    such as a dynamic propagation environment, human presence impact and terminals mobility. This chapter focuses on the practical aspects related to the real world-experimentation with distributed DSA network algorithms over a testbed network. Challenges and solutions are extensively discussed, from the testbed design......The problem of spectrum scarcity in uncoordinated and/or heterogeneous wireless networks is the key aspect driving the research in the field of flexible management of frequency resources. In particular, distributed dynamic spectrum access (DSA) algorithms enable an efficient sharing...... to the setup of experiments. A practical example of experimentation process with a DSA algorithm is also provided....

  1. Comparative evaluation of cerebral aneurysms with selective arterially enhanced CT and DSA

    International Nuclear Information System (INIS)

    Vanderschelden, P.; Flandroy, P.; Dondelinger, R.F.; Martin, D.; Lenelle, J.

    1998-01-01

    The purpose of our study was to compare selective arterially enhanced spiral computed tomographs (ACT) with digital subtraction angiographies (DSA) in the presurgical assessment of cerebral aneurysms. A total of 24 aneurysms in 18 patients were explored in a prospective study by ACT and DSA, using an interactive combined CT-angiography suite. Dimensions of the aneurysm, its relation to the parent vessel, and the aneurysmal index were defined on DSA and on surface-shaded display of 3D reformatted images obtained from ACT. Results were correlated with surgical findings. Three aneurysms suspected on DSA were not confirmed by ACT. One fusiform aneurysm suspected on DSA corresponded to a sacciform aneurysm on ACT. Surgical findings confirmed 20 sacciform aneurysms. The aneurysmal index could be measured in all 20 cases of sacciform aneurysms on ACT and could not be determined with confidence in 55 % of the cases on DSA. DSA and ACT gave identical results in 35 % of cases. In 10 %, the index measured by ACT was superior to that determined by DSA for aneurysms which had a diameter of less than 3 mm. In conclusion, the combination of DSA and ACT improved the results of DSA alone. ACT is a reliable method to measure the aneurysmal index in aneurysms with a diameter superior to 3 mm. (orig.)

  2. The generalized PN synthetic acceleration method for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.

    1997-01-01

    The diffusion synthetic acceleration (DSA) method has been known to be an effective tool for accelerating the iterative solution of transport equations with isotropic or mildly anisotropic scattering. However, the DSA method is not effective for transport equations that have strongly anisotropic scattering. A generalization of the modified DSA (MDSA) method is proposed that converges (clock time) faster than the MDSA method. This method is developed, the results of a Fourier analysis that theoretically predicts its efficiency are described, and numerical results that verify the theoretical prediction are presented

  3. [Design and development of the DSA digital subtraction workstation].

    Science.gov (United States)

    Peng, Wen-Xian; Peng, Tian-Zhou; Xia, Shun-Ren; Jin, Guang-Bo

    2008-05-01

    According to the patient examination criterion and the demands of all related departments, the DSA digital subtraction workstation has been successfully designed and is introduced in this paper by analyzing the characteristic of video source of DSA which was manufactured by GE Company and has no DICOM standard interface. The workstation includes images-capturing gateway and post-processing software. With the developed workstation, all images from this early DSA equipment are transformed into DICOM format and then are shared in different machines.

  4. Preoperative imaging in 78 living kidney donors using CE-MRA and DSA; Donor-Evaluation vor Lebendnierenspende: Vergleich von CE-MRA und DSA an 78 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Lemke, U.; Taupitz, M.; Hamm, B.; Kroencke, T.J. [Inst. fuer Radiologie, Charite - Universitaetsmedizin Berlin (Germany); Kluener, C. [Inst. fuer Radiologie und Neuroradiologie, Evangelisches Krankenhaus Oldenburg (Germany); Giessing, M.; Schoenberger, B. [Urologische Klinik und Poliklinik, Charite - Universitaetsmedizin Berlin (Germany)

    2008-01-15

    Purpose: to evaluate contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and digital subtraction angiography (DSA) in comparison with the intraoperative findings in living kidney donors. Materials and methods: a total of 156 kidneys in 78 potential kidney donors were prospectively examined using CE-MRA (0.2 mmol Gd/kg, voxel size 1.3 x 0.8 x 2.0) and DSA. Two experienced radiologists assessed the images in consensus regarding the renal vascular anatomy and variants. The results for the 67 candidates accepted for donation were compared to the intraoperative findings. In the other kidneys not accepted for donor nephrectomy, MRA and DSA were compared with each other. Results: nineteen arterial variants were identified intraoperatively, of which 11 (58%) were also detected by preoperative CE-MRA and 10 (53%) by preoperative DSA. Of the 10 venous variants found intraoperatively, CE-MRA detected 8 (80%) and DSA 3 (30%). The agreement (kappa test) between MRI and DSA for all 156 evaluated kidneys was 0.7 for arterial variants (McNemar p = 0.12) and 0.3 for venous variants (McNemar p = 0.01). The preoperative choice of kidney (right or left) made on the basis of the renal vascular anatomy seen on CE-MRA and DSA differed in 22% of the 78 potential donors (McNemar P = 0.3). (orig.)

  5. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Operations of the SuperHILAC, the Bevatron/Bevalac, and the 184-inch Synchrocyclotron during the period from October 1977 to September 1978 are discussed. These include ion source development, accelerator facilities, the Heavy Ion Spectrometer System, and Bevelac biomedical operations

  6. DSA diagnosis and embolization therapy of gastrointestinal hemorrhage

    International Nuclear Information System (INIS)

    Zhou Ruming; Qiu Shuibo; Liu Minhua; Yang Huijun; Zhuang Shaoyu

    2006-01-01

    Objective: To evaluate the effect of digital subtraction angiography and transcatheter embolization for gastrointestinal hemorrhage. Methods: Twenty patients with gastrointestinal hemorrhage received celiac arteries, superior mesenteric arteries and inferior mesenteric arteries angiography. Superselective angiography were performed when the arteries were suspicious by clinic or angiogrraphy. Ten patients with definite diagnosis and manifestation of hemorrhagic arteries by angiography were embolized after superselective catheterization with gelfoam particles, gelfoam particles and coils, polyvinyl alcohol particles. Results: The positive signs were observed in 13 cases. The DSA features including contrast medium accumulation in the gastrointestinal tract outside vascular, aneurysm, tumorous vascularization and staining, artery affect and local vasospasm. The bleedings were stopped immediately in 8 patients. No rebleeding and intestinal ischaemia or necrosis were observed in 30 days. One patient died in the second day after embolization from multiple organ failure. Rebleeding occurred 3 days after embolization in another patient, and was recovered after surgical operation. Conclusion: DSA is more effective for the diagnosis of gastrointestinal vascular malformation and tumors complicating acute bleeding. Transcatheter embolization is effective and safe to control the hemorrhage. (authors)

  7. Intra-arterial DSA of the mesenterico-spleno-portal vessels

    Energy Technology Data Exchange (ETDEWEB)

    Busch, H P; Hoevels, J; Prager, P; Strauss, L

    1985-01-01

    The article examines the application of i.a. DSA for the visualization of mesenterico-spleno-portal veins. Indications are portal hypertension and resectability assessment in pancreas tumours. Compared with conventional angiography, i.a. DSA yields a better demonstration of the splanchnic veins in about 50% of the cases. Advantages of i.a. DSA involve good-quality vessel visualization along with a reduction of examination time and cost. Its disadvantages are low-grade local resolution and strong dependence of picture quality on the patients' cooperation.

  8. In vitro and clinical evaluation of DSA in acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Rees, C.R.; Palmaz, J.C.; Alvarado, R.; Tyrrel, R.; Ciaravino, V.; Register, T.; Reuter, S.R.

    1987-01-01

    In an in vitro model of gastrointestinal (GI) bleeding, digital subtraction angiography (DSA) was found to be more accurate, more sensitive, and equally specific in the detection of extravasation compared to conventional screen-film angiography /sub chi//sup 2/, P < .05), DSA was used in the diagnosis and/or therapeutic management of 35 patients with GI bleeding (in the upper tract in 30, in the lower tract in five). When DSA results were negative (13 cases), results of conventional angiography were also negative. Upper GI bleeding episodes could be managed solely with DSA, which shortened examination times by 20% - 35%. The usefulness of DSA in lower GI bleeding was limited in the authors' series by a 9-inch image intensifier and misregistration caused by bowel motion

  9. Pre-transplant soluble CD30 in combination with total DSA but not pre-transplant C1q-DSA predicts antibody-mediated graft loss in presensitized high-risk kidney transplant recipients.

    Science.gov (United States)

    Schaefer, S M; Süsal, C; Opelz, G; Döhler, B; Becker, L E; Klein, K; Sickmüller, S; Waldherr, R; Macher-Goeppinger, S; Schemmer, P; Beimler, J; Zeier, M; Morath, C

    2016-02-01

    Presensitized kidney transplant recipients are at high-risk for early antibody-mediated rejection. We studied the impact of pre- and post-transplant donor-specific human leukocyte antigen (HLA) antibodies (DSA) and T-cell-activation on the occurrence of antibody-mediated rejection episodes (AMR) and graft loss (AMR-GL) in a unique cohort of 80 desensitized high-risk kidney transplant recipients. Patients with pre-transplant DSA demonstrated more AMR episodes than patients without DSA, but did not show a significantly increased rate of AMR-GL. The rates of AMR and AMR-GL were not significantly increased in patients with complement split product (C1q)-binding pre-transplant DSA. Pre-transplant C1q-DSA became undetectable post-transplant in 11 of 13 (85%) patients; 2 (18%) of these 11 patients showed AMR but no AMR-GL. In contrast, the post-transplant presence of C1q-DSA was associated with significantly higher rates of AMR (86 vs 33 vs 0%; P transplant DSA without C1q-binding or the absence of DSA. Patients with both pre-transplant DSA and evidence of pre-transplant T-cell-activation as indicated by soluble CD30-positivity showed a significantly increased risk for AMR-GL [HR = 11.1, 95% confidence interval (CI) = 1.68-73.4; log-rank P = 0.013]. In these high-risk patients, AMR-GL was associated with total DSA in combination with T-cell-activation pre-transplant, and de novo or persistent C1q-binding DSA post-transplant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Comparative analysis of CT and DSA in traumatic splenic salvage

    International Nuclear Information System (INIS)

    Liu Tie; Mao Xinfeng; Pan Feng

    2005-01-01

    Objective: To explore the better diagnostic method for acute splenic artery injury through comparative analysis of CT and DSA. Methods: Fifty-seven patients with acute splenic injury were examined by CT and DSA, treated with splenic arterial embolization and then undertook follow up. Results: CT examination possessed higher sensitivity and accuracy than DSA in demonstrating splenic parenchymal laceration, intrasplenic hematoma, subcapsular hematoma, rupture of splenic capsule and combined injury of intra-abdominal organs, especially in localizing splenic laceration. And there was a high significant difference statistically between the two kinds of examination (χ 2 =10.71, P 2 =12.57, P<0.005). Conclusions: CT and DSA are complementary in the diagnosis of splenic injury. After CT confirmation of splenic injury and the patient vital signs being stable, DSA should be referred to as soon as possible for further detail information as well as for possible interventional embolization and reduction of surgical complications. (authors)

  11. The generalized PN synthetic acceleration method for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.

    1998-01-01

    The diffusion synthetic acceleration (DSA) method has been known to be an effective tool for accelerating the iterative solution of transport equations with isotopic or mildly anisotropic scattering. However, the DSA method is not effective for transport equations that have strongly anisotropic scattering. A generalization of the modified DSA (MDSA) methods is proposed. This method converges (Clock time) faster than the MDSA method. It is developed, the results of a Fourier analysis that theoretically predicts its efficiency are described, and numerical results that verify the theoretical prediction are presented. (author). 9 refs., 2 tabs., 5 figs

  12. Accelerator operation management using objects

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, H.; Timossi, C.; Valdez, M.

    1995-04-01

    Conflicts over control of shared devices or resources in an accelerator control system, and problems that can occur due to applications performing conflicting operations, are usually resolved by accelerator operators. For these conflicts to be detected by the control system, a model of accelerator operation must be available to the system. The authors present a design for an operation management system addressing the issues of operations management using the language of Object-Oriented Design (OOD). A possible implementation using commercially available software tools is also presented.

  13. Accelerator operation management using objects

    International Nuclear Information System (INIS)

    Nishimura, H.; Timossi, C.; Valdez, M.

    1995-01-01

    Conflicts over control of shared devices or resources in an accelerator control system, and problems that can occur due to applications performing conflicting operations, are usually resolved by accelerator operators. For these conflicts to be detected by the control system, a model of accelerator operation must be available to the system. The authors present a design for an operation management system addressing the issues of operations management using the language of Object-Oriented Design (OOD). A possible implementation using commercially available software tools is also presented

  14. Fundamental study of DSA images using gadolinium contrast agent

    International Nuclear Information System (INIS)

    Nagashima, Hiroyuki; Shiraishi, Akihisa; Igarashi, Hitoshi; Sakamoto, Hajime; Sano, Yoshitomo

    2002-01-01

    Most contrast agents used in digital subtraction angiography (DSA) are non-ionic iodinated contrast agents, which can cause severe side effects in patients with contraindications for iodine or allergic reactions to iodine. Therefore, DSA examinations using carbon dioxide gas or examinations done by magnetic resonance imaging (MRI) and ultrasound (US) were carried out in these patients. However, none of these examinations provided mages as clear as those of DSA with an iodinated contrast agent. We experienced DSA examination using a gadolinium contrast agent in a patient contraindicated for iodine. The patient had undergone MRI examination with a gadolinium contrast agent previously without side effects. The characteristics of gadolinium and the iodinated contrast agent were compared, and the DSA images obtained clinically using these media were also evaluated. The signal-to-noise (SN) ratio of the gadolinium contrast agent was the highest at tube voltages of 70 to 80 kilovolts and improved slightly when the image intensifier (I.I.) entrance dose was greater than 300 μR (77.4 nC/kg). The dilution ratios of five iodinated contrast agents showed the same S/N value as the undiluted gadolinium contrast agent. Clinically, the images obtained showed a slight decrease in contrast but provided the data necessary to make a diagnosis and made it possible to obtain interventional radiology (IVR) without any side effects. DSA examinations using a gadolinium contrast agent have some benefit with low risk and are thought to be useful for patients contraindicated for iodine. (author)

  15. Peripheral occlusive vascular disease: Diagnostic performance of MRA and DSA

    International Nuclear Information System (INIS)

    Krug, B.; Kugel, H.; Harnischmacher, U.; Heindel, W.; Altenburg, A.; Fischbach, R.; Schmidt, R.

    1995-01-01

    In 59 patients with arterial flow disturbances 2-D inflow sequence of the abdominal and lower leg arteries were prospectively obtained on a 1.5 T MR-imager and were compared with additional DSA examinations. Supplementary Phase Contraste RSE ('Rapid Sequential Excitation') sequences were carried out in 29 patients. MRA and DSA angiograms were evaluated in random order by 4 readers using a questionnaire. The assessment of image quality were evaluated by variance analysis. Diagnostic performance of MRA and DSA was assessed by comparison of the readers' diagnostic assessments with reference diagnoses established by a radiologist and a vascular surgeon with full knowledge of all data concerning a patient. Image quality of inflow MRA was considered inferior to i.a. DSA (p [de

  16. Coregistration of three dimensional DSA and MR angiography in neuronavigation for neurosurgery

    International Nuclear Information System (INIS)

    Tang Weijun; Jin Yi; Li Ke; Feng Xiaoyuan; Hong Yong

    2007-01-01

    Objective: To assess the accuracy of neuronavigation of 3D DSA and to evaluate the feasibility of 3D DSA neuronavigational neurosurgery through the coregistration of 3D DSA and MRI(A). Methods: A Peg-Board Phantom was used in our study. The phantom consisted of 32 rods which were used for target localization; the height and the location of the rods were in normal distribution. For 3D DSA (Infinix NS/VC, Toshiba), the raw data was reconstructed to 3D images on the DSA workstation, and transferred to a online PC workstation where it was converted to standard 2D DICOM image data using WFU DICOM T oolkit software. For MRI (A), the phantom was scanned with FSPGR sequence on the MRI scanner (GE Signa VH/i 3.0 T), and the DICOM images were also transferred to the online PC workstation. Using the software 3D Slicer registration was performed on the PC workstation by using the location and shape of the rods in the phantom. The localization error of the rods was measured in image space as the Euclidean distance between targets defined in image space and those detected in the physical space. Paired t test was used to evaluate the difference between the accuracy of neuronaviagtion of 3D DSA and that of MRI(A). Results: Through the coregistration of the rods in the phantom from different modality, all the images were better coregistrated. The mean localization error was (0.38 ± 0.24)mm (3D DSA) and (0.31 ± 0.12)mm[MRI(A)]. There was no significant statistical difference between the accuracy of neuronavigation of 3D DSA and MRI(A) (t=-0.601, P=0.55). Conclusion: 3D DSA images can be used in the neuronavigation system through the coregistration of 3D DSA and MRI(A). (authors)

  17. Chronic thromboembolic pulmonary hypertension: diagnostic impact of multislice-CT and selective pulmonary-DSA

    International Nuclear Information System (INIS)

    Pitton, M.B.; Kemmerich, G.; Herber, S.; Schweden, F.; Thelen, M.; Mayer, E.

    2002-01-01

    Purpose: To evaluate the diagnostic impact of multislice-CT and selective pulmonary DSA in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: 994 vessel segments of 14 consecutive patients with CTEPH were investigated with multislice-CT (slice thickness 3 mm, collimation 2.5 mm, reconstruction intervall 2 mm) and selective pulmonary DSA posterior-anterior, 45 oblique, and lateral projection. Analysis was performed by 2 investigators independently for CT and DSA. Diagnostic criteria were occlusions and non-occlusive changes like webs and bands, irregularities of the vessel wall, diameter reduction and thromboembolic depositions at different levels from central pulmonary arteries to subsegmental arteries. Reference diagnosis was made by synopsis of CT and DSA by consensus. Results: Concerning patency CT and DSA showed concordant findings overall in 88.9%, 92.9% for segmental arteries and 85.4% for subsegmental arteries. Concerning any thromboembolic changes, multislice-CT was significantly inferior to selective DSA (concordance 67.0% overall, 70.4% for segments and 63.6% for subsegments). Non-occlusive changes of the vessels were significantly underdiagnosed by CT (concordance of CT versus DSA: 23.1%). Conclusion: Multislice-CT and selective pulmonary DSA are equivalent for diagnosis of vessel occlusions at the level of segmental and subsegmental arteries. However, for visualisation of the non-occlusive thromboembolic changes of the vessel wall selective pulmonary DSA is still superior compared to multislice-CT. Multislice-CT and selective pulmonary DSA are complementary tools for diagnosis and treatment planning of chronic thromboembolic pulmonary hypertension (CTEPH). (orig.) [de

  18. Value of infusion-DSA (Digital Subtraction Angiography) in diagnosis of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kwon, Jeong Mi; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duk

    1991-01-01

    In order to evaluate diagnostic effectiveness of the infusion-study, the authors prospectively evaluated hepatic digital subtraction angiography of bolus and infusion studies in 71 patients with hepatocellular carcinoma. In contrast to Bolus-DSA, which involves a 2 second injection of 10cc of contrast medium, the Infusion-DSA uses a protracted (10sec) injection, a lower injection rate, and larger total dose of contrast medium (20cc). The information yield of arterial and capillary phases of Infusion-DSA was compared with that of Bolus-DSA and graded as 'improved(+)', 'equivalent( ± )', or 'poor(-)'. Also, the contribution of Infusion-DSA to the diagnosis was classified into one of five in a graded system. In 29 hepatocellular patients, the Infusion-DSA was helpful in detecting daughter nodules, fibrous capsule and arteriovenous shunt. Infusion-DSA is a useful complementary technique in the diagnosis of hepatocellular carcinoma and was also helpful in determining the selection of the therapeutic modality of hepatocellular carcinoma

  19. The analysis of cerebro-vascular circulation time using digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Han, D. G.; Kim, D. H.; Lee, H. K.; Kwon, K. H.; Kim, K. J.

    1986-01-01

    We analyzed the cerebral arterio-venous circulation time of 141 cases of cranial DSA in 136 patients, for the assessment of cerebral circulatory dynamics. IV-DSA was 111 cases, IA-DSA 30 cases. The results were as follows: 1. There was no significant difference in arterio-venous circulation time between IA-DSA and IV-DSA, if the disease pattern was not considered (P > 0.1). 2. Prolongation of arterio-venous circulation time was noted in the cases of cerebral (cerebellar) hemorrhage, subarachnoid hemorrhage, intracranial hematoma, brain abscess, acute stage of cerebra-vascular occlusive disease, acute stage of postoperative follow up, and acute stage of cerebral contusion (p > 0.05). 3. Compared the chronic stage of cerebra-vascular occlusive disease, postoperative follow up, and cerebral contusion with acute stage, significant decrement of arterio-venous circulation time was resulted (p > 0.05). 4. DSA was a useful modality for the assessment of circulatory dynamics, including measurement of arterio-venous circulation time.

  20. Evaluation of the cerebral vasculature by intrarterial DSA - with emphasis on in vivo resolution

    International Nuclear Information System (INIS)

    Takahashi, M.; Bussaka, H.; Nakagawa, N.

    1984-01-01

    Comparative study was performed between IA DSA and stereoscopic magnification angiography in relation to small vessel resolution, image quality of the vessels and image quality of various pathologic lesions. The vessels of various diameters accurately measured by stereoscopic magnification angiography, were localized on IA DSA and their resolution was carefully assessed. The vessels more than 1 mm in diameter were equally visualized on IA DSA and conventional angiography. The vessels between 1 mm and 0.5 mm showed fair resolution on IA DSA, whereas IA DSA did not resolve the vessels smaller than 0.5 mm in diameter to good advantage. In addition, image quality of the vessels on IA DSA was compared with the conventional methods. Cerebral gyrus, venous sinuses, and intracerebral veins are often shown better on DSA. The small vessels such as lenticulostriate, small cortical, thalamoperforate and meningohypophyseal arteries were not defined on DSA. Equal or better image quality was obtained in more than 85% of cases with pathologic lesions. Examinations were performed faster with lower cost and lower complication rate. Information provided by DSA was often sufficient for managements of patients. Combined use of DSA and conventional angiography will improve diagnostic accuracy and decrease the complication rate. (orig.)

  1. The possible critical role of T-cell help in DSA-mediated graft loss.

    Science.gov (United States)

    Süsal, Caner; Slavcev, Antonij; Pham, Lien; Zeier, Martin; Morath, Christian

    2018-06-01

    In this review, we discuss a possible central role of T-cell help in severe forms of graft damage mediated by donor-specific HLA antibodies (DSA). Some kidney transplant recipients with pretransplant DSA show a high graft failure rate, whereas in other patients DSA do not harm the transplanted kidney and in most cases, disappear shortly after transplantation. Analyzing 80 desensitized highly immunized kidney transplant recipients and another multicenter cohort of 385 patients with pretransplant HLA antibodies, we reported recently that an ongoing T-cell help from an activated immune system, as measured by an increased level of soluble CD30 in serum, might be necessary for the DSA to exert a deleterious effect. Patients positive for both pretransplant DSA and sCD30 appear to require special measures, such as the elimination of DSA from the circulation, potent immunosuppression, good HLA-matching, and intense post-transplant monitoring, whereas exclusion of DSA-positive patients from transplantation in the absence of high sCD30 may not be justified in all cases, even if the pretransplant DSA are strong and complement-activating. © 2018 Steunstichting ESOT.

  2. The DSA appearance and its clinical significance in renovascular hypertension

    International Nuclear Information System (INIS)

    Su Guoqiang; Zhu Yaoqing; Gao Chongjing

    2000-01-01

    Objective: To discuss the DSA appearance of renovascular hypertension and the feasible necessity of dilatation of stenotic renal artery. Methods: DSA data of bilateral renal arteries of 21 patients, with suspected renovascular hypertension were analyzed. Results: Among those 21 patients, 11 did have stenoses in renal artery or its branches. Balloon dilatation were performed successfully in 6 patients. The successful rate was 54.55%. Conclusions: DSA is the preferable method for the diagnosis of renovascular hypertension, and offers reliable clinical data for interventional therapy

  3. Incidence and Factors Associated with De Novo DSA After BK Viremia in Renal Transplant Recipients.

    Science.gov (United States)

    Patel, Samir J; Kuten, Samantha A; Knight, Richard J; Graviss, Edward A; Nguyen, Duc; Gaber, A Osama

    2016-01-01

    BK polyomavirus infection and de novo donor-human leukocyte antigen (HLA) specific antibodies (dnDSA) are two well-known and distinct complications occurring after kidney transplantation. Recent literature suggests an association between the two events. This study aims to examine the relationship between BK viremia (BKV) and dnDSA and to identify potential risk factors for dnDSA following BKV in kidney transplant recipients. A retrospective review of 1019 recipients from Houston Methodist Hospital was conducted. All patients underwent routine screening for BKV and dnDSA. Median follow-up was 44 months. BKV was detected in 186 (18%) patients at a median of 107 (82-205) days post-transplant. dnDSA occurred in 283 (28%) patients at a median of 272 (62-575) days post-transplant. Of the 69 dnDSA-positive/BKV-positive patients, dnDSA detection occurred after BKV onset in 46 patients. Thus, 46 (28%) previously DSA-negative patients later became dnDSA-positive following BKV, not significantly different from the rate seen in BKV-negative patients (26%; p=0.5). Median time to DSA detection following BKV onset was 232 days (interquartile range, 119-460) post-BKV detection. Multivariate analysis revealed a greater number of HLA mismatches and viral clearance as risk factors for development of dnDSA following BKV, whereas delayed graft function was associated with a lower risk of dnDSA. In conclusion, despite being considered a result of over-immunosuppression, BKV can still be followed by dnDSA in a substantial proportion of patients. Monitoring for dnDSA in patients being managed for BKV may be warranted. Copyright© 2017 by the Terasaki Research Institute.

  4. Workshop on Accelerator Operation (WAO 2001)

    International Nuclear Information System (INIS)

    Bailey, R.

    2001-01-01

    The 3rd Workshop on Accelerator Operation (WAO 2001) followed earlier workshops in 1996 and 1998. Most topics relevant for the efficient and effective operation of accelerators were covered. These included the tools and utilities necessary in the control rooms; the organization of accelerator operation (process monitoring, shift work, stress); the monitoring of beam quality; safety issues and standards; and questions particularly relevant for superconducting accelerators, in particular cryogenics. (author)

  5. The protection of radioactive nuclide and nursing management in DSA room

    International Nuclear Information System (INIS)

    Zhang Guimin

    2009-01-01

    Objective: To discuss the protection of radioactive nuclide and nursing management in DSA room. Methods: The clinical state of the protection of radioactive 131 I nuclide and nursing management in DSA room was retrospectively summarized. Results: The standard management for the protection of radioactive nuclide in DSA room was established. The main management schemas included the management of personnel, the management of professional skills and, specialty, the management of radioactive drugs and abandoned odds and ends, preoperative health education, etc. Conclusion: The standard management can ensure that the patients get a good radionuclide therapy in DSA room, and, at the same time, the working environment can be effectively protected and the professional nursing staff can be well trained. (authors)

  6. Clinical application of digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Morimoto, Tadashi; Kaku, Suiei; Morikawa, Eiji

    1984-01-01

    Intra-arterial digital subtraction angiography (IA-DSA) by the direct puncture of the carotid artery was described with special reference to its techniques, and cases were presented. This method was safe and painless and could be performed repeatedly. Cerebral angiographic images obtained by this method were either superior or fully compatible to the conventional cerebral angiography. It is therefore of great diagnostic value and can replace the conventional method. Furthermore, since the pretreatment is unnecessary and the time required is short, IA-DSA can be used as an adjuvant method for emergency diagnosis. (Namekawa, K)

  7. Accelerator Operators and Software Development

    International Nuclear Information System (INIS)

    April Miller; Michele Joyce

    2001-01-01

    At Thomas Jefferson National Accelerator Facility, accelerator operators perform tasks in their areas of specialization in addition to their machine operations duties. One crucial area in which operators contribute is software development. Operators with programming skills are uniquely qualified to develop certain controls applications because of their expertise in the day-to-day operation of the accelerator. Jefferson Lab is one of the few laboratories that utilizes the skills and knowledge of operators to create software that enhances machine operations. Through the programs written; by operators, Jefferson Lab has improved machine efficiency and beam availability. Because many of these applications involve automation of procedures and need graphical user interfaces, the scripting language Tcl and the Tk toolkit have been adopted. In addition to automation, some operator-developed applications are used for information distribution. For this purpose, several standard web development tools such as perl, VBScript, and ASP are used. Examples of applications written by operators include injector steering, spin angle changes, system status reports, magnet cycling routines, and quantum efficiency measurements. This paper summarizes how the unique knowledge of accelerator operators has contributed to the success of the Jefferson Lab control system. *This work was supported by the U.S. DOE contract No. DE-AC05-84-ER40150

  8. Indications for intravenous and intraarterial digital subtraction angiography (DSA) in the diagnosis of cerebrovascular insufficiency

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Friedmann, G.

    1985-01-01

    For screening of arteriosclerotic lesions of the carotid bifurcation duplex scanning (B-mode imaging plus doppler flow analysis) is the method of first choice, because it is really noninvasive and offers the same results as intravenous DSA (IV DSA). IV DSA should not be performed as a screening procedure unless ultrasound examinations are not available or are inadequate. Except for patients with isolated unilateral stenosis of the internal carotid artery near the bifurcation confirmed with both duplex scanning and IV DSA, arteriography is required for therapy planning. Aortic arch angiogram, selective extra- and intracranial carotid arteriography and - if necessary - vertebral and subclavian arteriography can be performed with intraarterial DSA (IA DSA). The application of DSA to catheter arteriography will help to reduce further the potential risk of adverse reactions related to high intravasal contrast does specially in the cerebral circulation, but will not turn arteriography into a risk-free procedure. Postoperative examinations of the carotid bifurcation can be performed with ultrasound as well as with IV DSA. Extracranial bypasses are best demonstrated with IV DSA. Extraintracranial bypasses can be demonstrated only with IA DSA. (orig.)

  9. Preoperative imaging in 78 living kidney donors using CE-MRA and DSA

    International Nuclear Information System (INIS)

    Lemke, U.; Taupitz, M.; Hamm, B.; Kroencke, T.J.; Kluener, C.; Giessing, M.; Schoenberger, B.

    2008-01-01

    Purpose: to evaluate contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and digital subtraction angiography (DSA) in comparison with the intraoperative findings in living kidney donors. Materials and methods: a total of 156 kidneys in 78 potential kidney donors were prospectively examined using CE-MRA (0.2 mmol Gd/kg, voxel size 1.3 x 0.8 x 2.0) and DSA. Two experienced radiologists assessed the images in consensus regarding the renal vascular anatomy and variants. The results for the 67 candidates accepted for donation were compared to the intraoperative findings. In the other kidneys not accepted for donor nephrectomy, MRA and DSA were compared with each other. Results: nineteen arterial variants were identified intraoperatively, of which 11 (58%) were also detected by preoperative CE-MRA and 10 (53%) by preoperative DSA. Of the 10 venous variants found intraoperatively, CE-MRA detected 8 (80%) and DSA 3 (30%). The agreement (kappa test) between MRI and DSA for all 156 evaluated kidneys was 0.7 for arterial variants (McNemar p = 0.12) and 0.3 for venous variants (McNemar p = 0.01). The preoperative choice of kidney (right or left) made on the basis of the renal vascular anatomy seen on CE-MRA and DSA differed in 22% of the 78 potential donors (McNemar P = 0.3). (orig.)

  10. Accelerator operation in 1995-1996

    International Nuclear Information System (INIS)

    Loyer, F.

    1998-01-01

    This report presents the operation of the GANIL accelerator between 1995 and 1996. A table is given in which the time distribution of the accelerator operation in the two years is indicated as: beam availability, time devoted to nuclear and non-nuclear physics research, radioactive ion separator operation, industrial irradiation, machine studies and maintenance. A statistics of the accelerated elements and their energy (MeV/u) shows an increase in the number of beam types and new beams from 18 and 9, respectively, in 1995 to 19 and 11 respectively in 1996. The report mentions also the safety incident of June 9, 1995, the failures in operation in 1995-1996 and events connected to SISSI, UGS-R and THI operations

  11. On the use of diffusion synthetic acceleration in parallel 3D neutral particle transport calculations

    International Nuclear Information System (INIS)

    Brown, P.; Chang, B.

    1998-01-01

    The linear Boltzmann transport equation (BTE) is an integro-differential equation arising in deterministic models of neutral and charged particle transport. In slab (one-dimensional Cartesian) geometry and certain higher-dimensional cases, Diffusion Synthetic Acceleration (DSA) is known to be an effective algorithm for the iterative solution of the discretized BTE. Fourier and asymptotic analyses have been applied to various idealizations (e.g., problems on infinite domains with constant coefficients) to obtain sharp bounds on the convergence rate of DSA in such cases. While DSA has been shown to be a highly effective acceleration (or preconditioning) technique in one-dimensional problems, it has been observed to be less effective in higher dimensions. This is due in part to the expense of solving the related diffusion linear system. We investigate here the effectiveness of a parallel semicoarsening multigrid (SMG) solution approach to DSA preconditioning in several three dimensional problems. In particular, we consider the algorithmic and implementation scalability of a parallel SMG-DSA preconditioner on several types of test problems

  12. Application of the DSA preconditioned GMRES formalism to the method of characteristics - First results

    International Nuclear Information System (INIS)

    Le Tellier, R.; Hebert, A.

    2004-01-01

    The method of characteristics is well known for its slow convergence; consequently, as it is often done for SN methods, the Generalized Minimal Residual approach (GMRES) has been investigated for its practical implementation and its high reliability. GMRES is one of the most effective Krylov iterative methods to solve large linear systems. Moreover, the system has been 'left preconditioned' with the Algebraic Collapsing Acceleration (ACA) a variant of the Diffusion Synthetic Acceleration (DSA) based on I. Suslov's former works. This paper presents the first numerical results of these methods in 2D geometries with material discontinuities. Indeed, previous investigations have shown a degraded effectiveness of Diffusion Synthetic Accelerations with this kind of geometries. Results are presented for 9 x 9 Cartesian assemblies in terms of the speed of convergence of the inner iterations (fixed source) of the method of characteristics. It shows a significant improvement on the convergence rate. (authors)

  13. The availability of DSA used continuous intraarterial infusion tubes founded various malignancy

    International Nuclear Information System (INIS)

    Minakuchi, Kazuo; Kobayashi, Nobuyuki; Yamada, Tetsuya

    1987-01-01

    DSA was employed using continuous intraarterial infusion tubes for various malignancies (73 cases) which were examined a total of 135 times. In head and neck malignancy (50 cases), the general position of the infusion tube had been determined beforehand by dye infusion, but DSA from the tube showed that the tubes in 24 cases (48 %) were located in the wrong position, especially in tongue cancer (21 cases) where many tubes were discovered to be in an erroreous position (71 %) such as the common carotid artery. We were unable to determine the effect of chemotherapy and radiation using DSA only. In 9 cases of breast cancer for which fixation of the tube was not attempted under X-ray fluoroscopy, 7 (78 %) showed an unusual tube position such as the intraaortic arch. In 5 cases of abdominal malignancy, only the tube position for sigmoid colon cancer was unusual. We were able to observe the effect of chemotherapy by DSA in 2 cases. For DSA in one out of 3 hepatomas using a Port-A-Cath, we observed that infusion of anticancer drug with degradable starch microspheres caused a reduction in tumor size. However, in the two remaining cases, we were unable to observe any effect of infusion of these drugs by DSA for various mechanical reasons. DSA from an infusion tube revealed not only the location of the tube accurately and promptly, but also the effect of chemotherapy. (author)

  14. The clinical application of inferior vena caval CO2-DSA

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; Li Guozhao; Fang Wen; He Shicheng; Deng Tang

    2007-01-01

    Objective: To explore the feasibility and safety of inferior vena caval CO 2 -DSA and evaluate the results of inferior vena cavography using CO 2 -DSA or iodinated contrast media. Methods: 25 patients diagnosed as deep venous thrombosis of lower limb were prepared to conceive the implantation of inferior vena caval filter. The inferior vena cava and right renal vein CO 2 -DSA and iodinated contrast media DSA were carried out through jugular or femoral vein approach in all patients. Results: The inferior vena caval angiography with CO 2 -DSA or iodinated contrast media were carried out successfully in all patients. The quality of the inferior vena caval angiogram showed: with CO 2 as contrast media, 14 cases obtained excellent images and 11 cases had good images; with iodinated contrast media the images of 18 cases were excellent and 7 cases were good. No thrombus and variation of inferior vena cava were found by the two kinds of angiography. The diameter of inferior vena cava showed: (20.01 ± 0.83) mm with CO 2 contrast media and (20.15 ± 0.92) mm with iodinated contrast media, (P=0.006); having statistical significance between them. The safety of angiography with CO 2 presented only 1 case with transient slight decrease of O 2 saturation. No abnormal changes were found in blood pressure, heart rate and so on. Conclusions: Inferior vena caval CO 2 -DSA is feasible and safe, with statistical significance in the measurement of inferior vena caval diameter comparing with iodinated contrast material but with no influence on the implantation of filter. (authors)

  15. INJECTION TO RAPID DIFFUSIVE SHOCK ACCELERATION AT PERPENDICULAR SHOCKS IN PARTIALLY IONIZED PLASMAS

    Energy Technology Data Exchange (ETDEWEB)

    Ohira, Yutaka, E-mail: ohira@phys.aoyama.ac.jp [Department of Physics and Mathematics, Aoyama Gakuin University, 5-10-1 Fuchinobe, Sagamihara 252-5258 (Japan)

    2016-08-10

    We present a three-dimensional hybrid simulation of a collisionless perpendicular shock in a partially ionized plasma for the first time. In this simulation, the shock velocity and upstream ionization fraction are v {sub sh} ≈ 1333 km s{sup −1} and f {sub i} ∼ 0.5, which are typical values for isolated young supernova remnants (SNRs) in the interstellar medium. We confirm previous two-dimensional simulation results showing that downstream hydrogen atoms leak into the upstream region and are accelerated by the pickup process in the upstream region, and large magnetic field fluctuations are generated both in the upstream and downstream regions. In addition, we find that the magnetic field fluctuations have three-dimensional structures and the leaking hydrogen atoms are injected into the diffusive shock acceleration (DSA) at the perpendicular shock after the pickup process. The observed DSA can be interpreted as shock drift acceleration with scattering. In this simulation, particles are accelerated to v ∼ 100 v {sub sh} ∼ 0.3 c within ∼100 gyroperiods. The acceleration timescale is faster than that of DSA in parallel shocks. Our simulation results suggest that SNRs can accelerate cosmic rays to 10{sup 15.5} eV (the knee) during the Sedov phase.

  16. Correlation between the clinical presentation and DSA of intracranial aneurysms

    International Nuclear Information System (INIS)

    Fang Chun; Hua Jia; Chen Kemin; Yin Yan; Ge Xin; Ying Yiping

    2001-01-01

    Objective: To evaluate the correlation between the clinical presentation and cerebral angiographic features of intracranial aneurysms. Methods: The authors retrospectively analyzed the relationship between the size, location and shape of 48 patient's cerebral aneurysms and their clinical presentations. Results: Clinical symptoms of cerebral aneurysms were related with their size, location and shape. Aneurysms in different location or at same location may cause similar symptoms or different symptoms. Rotation DSA is a useful examination supplemented to conventional DSA. Conclusions: The relationship between the location and the presentation of intracranial aneurysms is not specific. Rotation DSA plays important role in showing the characteristics of the cerebral aneurysms

  17. Dsa examination and diagnosis of arteriovenous shunts in hepatic cavernous hemangiomas of adults

    International Nuclear Information System (INIS)

    Ouyang Yong; Ouyang Xuehui; Gu Subin; Zhou Qunhui

    2000-01-01

    Objective: To correct the misunderstanding that arteriovenous shunts (AVS) are rarely found in adult cavernous hemangiomas of the liver (CHL) and to increase its diagnosis rate by DSA. Methods: DSA examination and DSA images of thirty adults with definitely diagnostic CHL and without evidence of other hepatic diseases and hepatic injury were analyzed retrospectively. X-ray films of 21 cases with AVS taken immediately after transcatheter arterial embolization using lipiodol (L-TAE) were compared with the corresponding DSA images to check up those AVS opacified in DSA by observing sediment and distribution of iodized oil injected. Results: Definite diagnosis of AVS by DSA were obtained in 22 cases of this series (73%). All the AVS were located in the peritumoral parenchyma and appeared as parallel track sign, and early opacification of small draining veins, etc. during arterial phase of DSA. X-ray films taken immediately after L-TAE in 21 of 22 cases with AVS showed that few portal radicles or draining veins were refilled by iodized oil through incompletely occluded shunts in 11 cases, and no any vein was refilled by iodized oil resulted from complete occlusion of the present AVS in 10. No definite AVS was found in the other 8 cases of this series, and in 6 of them improper imaging factors of DSA were used. Conclusion: This study serves to emphasize that AVS is not a diagnosis of hepatic malignancy, but is frequently seen in the commonly benign CHL of adults. Proper imaging factors of DSA and superior images can be helpful to opacify small AVS of CHL. The formation of AVS in CHL may be closely related to the pathological changes of peritumoral parenchyma, however, its mechanism must be further studied

  18. Complications of intravenous DSA: Results in 500 patients

    International Nuclear Information System (INIS)

    Gross-Fengels, W.; Neufang, K.F.R.; Beyer, D.; Steinbrich, W.

    1987-01-01

    500 patients were studied respectively for complications of intravenous digital subtraction angiography (IV-DSA) performed with non-ionic contrast media, using a central venous injection technique. In 21 patients (4,2%) during or shortly after the procedure 23 systemic, 1 neurologic, and 7 local complications occurred. In addition, 1 patient developed acute renal failure 26 hours after the IV-DSA, whereas 4 patients later showed on thromboses of the catheterised vein. No permanent neurologic or systemic complications and severe allergic reactions were seen. (orig.) [de

  19. Measurements of image characteristics of DSA installations

    International Nuclear Information System (INIS)

    Busch, H.P.; Strauss, L.G.; Freimarck, R.D.

    1984-01-01

    Measurements for quantifying the image characteristics were carried out on three DSA installations (DVI 1 - Philips, Angiotron - Siemens and DF 3000 - General Eletric). Contrast resolution was measured with a vessel phantom (General Electric) and spatial resolution with a lead grid. A further parameter was the dose entering the image intensifier. The Angiotron was used with an intensifier with 53 cm. diameter and the DF 3000 with temporal subtraction of the video images and the subtraction of dual energy images (hybrid technique). These measurements can be carried out quickly and easily and are a step towards standardisation of measurements of image characteristics of DSA installations. (orig.) [de

  20. Tandem accelerator operation and improvements

    International Nuclear Information System (INIS)

    Yang Bingfan; Zhang Canzhe; Qin Jiuchang; Hu Yueming; Zhang Guilian; Jiang Yongliang; Hou Deyi; Yang Weimin; Yang Zhiren; Su Shengyong; Kan Chaoxin; Liu Dezhong; Wang Liyong; Bao Yiwen; You Qubo; Yang Tao; Zhang Yan; Zhou Lipeng; Chai Shiqin; Wang Meiyan

    1998-01-01

    The scheduled operation of HI-13 tandem accelerator for various experiments was performed well in 1996 and 1997. The machine running time was 4600 h and 4182 h while the beam time was 3845 h and 3712 h in 1996 and 1997, respectively. The operation of HI-13 tandem accelerator is pretty well. The beam distribution with terminal voltage and the distribution of beam time with ion species are shown out. The development of accelerating tubes for HI-13 tandem is in progress

  1. Visceral angiography with intra-arterial DSA and a programmed 100 mm technique

    International Nuclear Information System (INIS)

    Triller, J.; Ackermann, B.; Jung, H.

    1988-01-01

    One hundred and seventy specially selected visceral angiograms were carried out of 96 patients using I-A DSA and 100 mm technique. 85.2% of the I-A DSA and 91.7% of the 100 mm images were of good quality. I-A DSA produced comparable or better quality than the 100 mm technique in 66% during the arterial phase, in 79% during the paranchymatous phase and in 70% during the venous phase. The 100 mm technique produced better quality in a third of the cases during the arterial phase and in a quarter of the cases during the parenchymal and venous phases. The indications for the 100 mm technique are failure of I-A DSA or the need for high spatial resolution. (orig.) [de

  2. Acceleration of Solar Energetic Particles at a Fast Traveling Shock in Non-uniform Coronal Conditions

    Science.gov (United States)

    Le Roux, J. A.; Arthur, A. D.

    2017-09-01

    Time-dependent solar energetic particle (SEP) acceleration is investigated at a fast, nearly parallel spherical traveling shock in the strongly non-uniform corona by solving the standard focused transport equation for SEPs and transport equations for parallel propagating Alfvén waves that form a set of coupled equations. This enables the modeling of self-excitation of Alfvén waves in the inertial range by SEPs ahead of the shock and its role in enhancing the efficiency of the diffusive shock acceleration (DSA) of SEPs in a self-regulatory fashion. Preliminary results suggest that, because of the highly non-uniform coronal conditions that the shock encounters, both DSA and wave excitation are highly time-dependent processes. Thus, DSA spectra of SEPs strongly deviate from the simple power-law prediction of standard steady-state DSA theory and initially strong wave excitation weakens rapidly. Consequently, the ability of DSA to produce high energy SEPs in the corona of ∼1 GeV, as observed in the strongest gradual SEP events, appears to be strongly curtailed at a fast nearly parallel shock, but further research is needed before final conclusions can be drawn.

  3. Nuclear lifetime measurements with the DSA coincidence method in inverse reactions

    International Nuclear Information System (INIS)

    Hermans, J.A.J.

    1977-01-01

    This thesis describes lifetime measurements with the DSA coincidence method in inverse reactions. Bombardment of 2 H and 3 H targets with heavy ions of energies up to 50 MeV produces nuclei recoiling at initial velocities of v(0) approximately equal to 0.05 c. Heavy-ion beams of 11 B, 12 C, 14 N, 16 O, 18 O, 19 F, 27 A1, 28 Si, 30 Si, 31 P, 32 S, 35 Cl and 37 Cl are at present available from the Utrecht 6 MV EN tandem accelerator. The recoil nuclei are slowed down in Mg, Al, Cu, Ag or Au and the γ-ray Doppler pattern is observed with a large Ge(Li) detector in coincidence with protons

  4. Operation of the tandem-linac accelerator

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The tandem-linac accelerator system is operated as a source of energetic heavy-ion projectiles for research in several areas of nuclear physics and occasionally in other areas of science. The accelerator system consists of a 9-MV tandem electrostatic accelerator and a superconducting-linac energy booster that can provide an additional 20 MV of acceleration. A figure shows the layout of this system, which will be operated in its present form until September 1985, when it will be incorporated into the larger ATLAS system. In both the present and future forms the accelerator is designed to provide the exceptional beam quality and overall versatility required for precision nuclear-structure research

  5. Internal carotid artery stenosis or occlusion: study of collateral circulation pathways on DSA and MRA

    International Nuclear Information System (INIS)

    Zhao Yunhui; Ma Zhubin; Xu Yikai

    2004-01-01

    Objectives: To evaluate the collateral pathways of internal carotid artery (ICA) stenosis or occlusion on digital subtraction angiography (DSA) and magnetic resonance angiography (MRA), and to compare these two methods in the study for collateral pathways. Methods: Seventy-four patients with ICA stenosis or occlusion were included as the study group. Sixty persons with normal findings on DSA or MRA each served as the control group. DSA, MRA, MRI, CT findings, and clinicall materials were analyzed in the two groups. Results: Stenosis or occlusion over ICA bifurcation was showed clearly in all patients on DSA or MRA. On DSA, the presence rate of ipsilateral posterior communicating artery (PCoA) in the study group (82.5%) was lower significantly than that of the control group (94.2%) (P=0.025). On MRA (3D-TOF), the rate in the study group (59.3%) was higher significantly than that of the controls (30.0%) (P=0.000). On DSA and MRA, the diameter of ipsilateral PCoA in the study group was larger than that of the control group (P=0.000). On DSA, the presence rate of OPhA in the study group was significantly different from that of the control group, and its diameter was larger than that of the control group (P=0.003). On MRA, its presence rate was lower than that of the control group. The presence rate of anterior communicating artery (ACoA) in the study group showed no statistical difference between DSA and MRA. In the study group, the presence rate of PCoA on DSA was significantly higher than that on MRA (P 0.05). The diameters of the three arteries showed no significant differences between DSA and MRA (P>0.05). Conclusion: DSA is highly valuable for the evaluation of collateral pathways of ICA stenosis or occlusion, and it is necessary for preoperative examination. MRA is a non-invasive angiographic method and can evaluate collateral circulation in both morphology and function, and can be the preferred method for the disease. (authors)

  6. Operational experience of the ATLAS accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Den Hartog, P K; Bogaty, J M; Bollinger, L M; Clifft, B E; Craig, S L; Harden, R E; Markovich, P; Munson, F H; Nixon, J M; Pardo, R C; Phillips, D R; Shepard, K W; Tilbrook, I R; Zinkmann, G P [Argonne National Lab., IL (USA). Physics Div.

    1990-02-01

    The ATLAS accelerator consists of a HVEC model FN tandem accelerator injecting into a linac of independently-phased niobium superconducting resonators. The accelerator provides beams with masses 6 {le} A {le} 127 and with energies ranging up to 20 MeV/A for the lightest ions and 4 MeV/A for the heaviest ions. Portions of the linac have been in operation since 1978 and, over the last decade, more than 35000 h of operating experience have been accumulated. The long-term stability of niobium resonators, and their feasibility for use in heavy-ion accelerators is now well established. (orig.).

  7. Continuity of Accelerator Operations during an Extended Pandemic

    International Nuclear Information System (INIS)

    Noel Okay

    2010-01-01

    The Operations group for the Continuous Electron Accelerator Facility in Newport News Virginia has developed a Continuity of Operations plan for pandemic conditions when high absenteeism may impact accelerator control room operations. Protocols to address both the potential spread of illnesses in the control room environment as well as maintaining minimum staffing requirements for contiguous accelerator operation will be presented. During acute pandemic conditions local government restrictions may prevent continued operations but during extended periods of high absenteeism accelerator operations can continue when some added precautionary measures and staffing adjustments are made in the way business is done.

  8. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This section is concerned with the operation of both the tandem-linac system and the Dynamitron, two accelerators that are used for entirely different research. Developmental activities associated with the tandem and the Dynamitron are also treated here, but developmental activities associated with the superconducting linac are covered separately because this work is a program of technology development in its own right

  9. Just in Time DSA the Hanford Nuclear Safety Basis Strategy

    Energy Technology Data Exchange (ETDEWEB)

    JACKSON, M.W.

    2002-06-01

    The U.S. Department of Energy, Richland Operations Office (RL) is responsible for 30 hazard category 2 and 3 nuclear facilities that are operated by its prime contractors, Fluor Hanford, Incorporated (FHI), Bechtel Hanford, Incorporated (BHI) and Pacific Northwest National Laboratory (PNNL). The publication of Title 10, Code of Federal Regulations, Part 830, Subpart B, Safely Basis Requirements (the Rule) in January 2001 requires that the Documented Safety Analyses (DSA) for these facilities be reviewed against the requirements of the Rule. Those DSAs that do not meet the requirements must either be upgraded to satisfy the Rule, or an exemption must be obtained. RL and its prime contractors have developed a Nuclear Safety Strategy that provides a comprehensive approach for supporting RL's efforts to meet its long-term objectives for hazard category 2 and 3 facilities while also meeting the requirements of the Rule. This approach will result in a reduction of the total number of safety basis documents that must be developed and maintained to support the remaining mission and closure of the Hanford Site and ensure that the documentation that must be developed will support: Compliance with the Rule; A ''Just-In-Time'' approach to development of Rule-compliant safety bases supported by temporary exemptions; and Consolidation of safety basis documents that support multiple facilities with a common mission (e.g. decontamination, decommissioning and demolition [DD&D], waste management, surveillance and maintenance). This strategy provides a clear path to transition the safety bases for the various Hanford facilities from support of operation and stabilization missions through DD&D to accelerate closure. This ''Just-In-Time'' Strategy can also be tailored for other DOE Sites, creating the potential for large cost savings and schedule reductions throughout the DOE complex.

  10. Just in Time DSA the Hanford Nuclear Safety Basis Strategy

    International Nuclear Information System (INIS)

    JACKSON, M.W.

    2002-01-01

    The U.S. Department of Energy, Richland Operations Office (RL) is responsible for 30 hazard category 2 and 3 nuclear facilities that are operated by its prime contractors, Fluor Hanford, Incorporated (FHI), Bechtel Hanford, Incorporated (BHI) and Pacific Northwest National Laboratory (PNNL). The publication of Title 10, Code of Federal Regulations, Part 830, Subpart B, Safely Basis Requirements (the Rule) in January 2001 requires that the Documented Safety Analyses (DSA) for these facilities be reviewed against the requirements of the Rule. Those DSAs that do not meet the requirements must either be upgraded to satisfy the Rule, or an exemption must be obtained. RL and its prime contractors have developed a Nuclear Safety Strategy that provides a comprehensive approach for supporting RL's efforts to meet its long-term objectives for hazard category 2 and 3 facilities while also meeting the requirements of the Rule. This approach will result in a reduction of the total number of safety basis documents that must be developed and maintained to support the remaining mission and closure of the Hanford Site and ensure that the documentation that must be developed will support: Compliance with the Rule; A ''Just-In-Time'' approach to development of Rule-compliant safety bases supported by temporary exemptions; and Consolidation of safety basis documents that support multiple facilities with a common mission (e.g. decontamination, decommissioning and demolition [DD and D], waste management, surveillance and maintenance). This strategy provides a clear path to transition the safety bases for the various Hanford facilities from support of operation and stabilization missions through DD and D to accelerate closure. This ''Just-In-Time'' Strategy can also be tailored for other DOE Sites, creating the potential for large cost savings and schedule reductions throughout the DOE complex

  11. Intra-arterial digital subtraction angiography (IA-DSA) with carbon dioxide

    International Nuclear Information System (INIS)

    Takeda, Toshiaki; Ido, Kunio; Yuasa, Yuji

    1988-01-01

    Intra-Arterial Digital Subtraction Angiography (IA-DSA) with Carbon Dioxide (CO 2 ) was performed on 41 patients mainly with liver or renal diseases, and its angiographic manifestation was compared with that of conventional angiography. Although the image quality of the arterial or capillary phase was inferior to that of conventional angiography with iodinated contrast media, the detectablity of arterio-venous shunting was excellent. In fact, DSA with CO 2 revealed the presence of A-V (A-P) shunt in 26 patients (26/41:63.4 % HCC, 13/15:86.7% metastatic liver tumor, 2/3:66.7 % RCC, 1/5:20 %). On the other hand, conventional angiography was able to show in only 5 cases. DSA with CO 2 will become an effective method for detecting minute arterio-venous shunting which can not be demonstrated with conventional angiography. (author)

  12. IV-DSA of vertigo patients

    International Nuclear Information System (INIS)

    Watanabe, Hiromi; Ito, Masatoshi; Takita, Kimio; Matsuzawa, Taiju.

    1988-01-01

    With IV-DSA(Intra-Venous Digital Subtraction Angiography), we examined the relations between vertigo or dizziness and asymmetries of cervical vertebral arteries. In this time, as the asymmetries we chose next three; hemi-stenosis, hemi-occulusion and hemi-strong tortuosity. In the appearance of the asymmetries, there was no differance between those who complain vertigo or dizziness and others. (author)

  13. Operational experience of the ATLAS accelerator

    International Nuclear Information System (INIS)

    Den Hartog, P.K.; Bogaty, J.M.; Bollinger, L.M.

    1989-01-01

    The ATLAS accelerator consists of a HVEC model FN tandem accelerator injecting into a linac of independently-phased niobium superconducting resonators. The accelerator provides beams with masses from 6≤A≤127 and with energies ranging up to 20 MeV/A for the lightest ions and 4 MeV/A for the heaviest ions. Portions of the linac have been in operation since 1978 and, over the last decade, more than 35,000 hours of operating experience have been accumulated. The long-term stability of niobium resonators, and their feasibility for use in heavy-ion accelerators is now well established. 11 refs., 3 figs., 1 tab

  14. DSA volumetric 3D reconstructions of intracranial aneurysms: A pictorial essay

    Science.gov (United States)

    Cieściński, Jakub; Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-01-01

    Summary A gold standard of cerebral vessel imaging remains the digital subtraction angiography (DSA) performed in three projections. However, in specific clinical cases, many additional projections are required, or a complete visualization of a lesion may even be impossible with 2D angiography. Three-dimensional (3D) reconstructions of rotational angiography were reported to improve the performance of DSA significantly. In this pictorial essay, specific applications of this technique are presented in the management of intracranial aneurysms, including: preoperative aneurysm evaluation, intraoperative imaging, and follow-up. Volumetric reconstructions of 3D DSA are a valuable tool for cerebral vessels imaging. They play a vital role in the assessment of intracranial aneurysms, especially in evaluation of the aneurysm neck and the aneurysm recanalization. PMID:22844309

  15. A grey diffusion acceleration method for time-dependent radiative transfer calculations: analysis and application

    International Nuclear Information System (INIS)

    Nowak, P.F.

    1993-01-01

    A grey diffusion acceleration method is presented and is shown by Fourier analysis and test calculations to be effective in accelerating radiative transfer calculations. The spectral radius is bounded by 0.9 for the continuous equations, but is significantly smaller for the discretized equations, especially in the optically thick regimes characteristic to radiation transport problems. The GDA method is more efficient than the multigroup DSA method because its slightly higher iteration count is more than offset by the much lower cost per iteration. A wide range of test calculations confirm the efficiency of GDA compared to multifrequency DSA. (orig.)

  16. IV DSA in the diagnosis and follow-up of dissection of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickx, P.; Luska, G.; Laas, J.; Haverich, A.

    1986-05-01

    Intravenous DSA was performed in 53 patients with suspected dissection of the thoracic aorta and in 13 patients following surgery for aortic dissection. In 36 patients, the suspected diagnosis could be excluded definitely and, in 14 cases out of 17, a dissection was correctly diagnosed. All 11 type B dissections were correctly diagnosed. Of six type A dissections, only three were adequately demonstrated by IV DSA. In type B dissections, IV DSA is reliable, but in type A dissection with massive aortic insufficiency or pericardial tamponade the findings are not reliable. In all 13 patients who had surgery for dissection, IV DSA proved suitable for showing the anastomosis and progress of the disease.

  17. Advantages and limitation of intra-arterial digital subtraction angiography (i.a. DSA)

    International Nuclear Information System (INIS)

    Beduhn, D.

    1986-01-01

    Among 3000 digital subtraction angiographies which have been performed in our institute, 850 patients have been examined intraarterially. The advantage of i.a. DSA is due to the excellent demonstration of vessels in survey angiograms by small amounts of contrast medium (10-20 ml in the aorta), without risk of selective catheterisation into the neck vessels, the saving of expensive film series, the short duration of vessel examinations and the small complication rate. i.a. DSA can be carried out on outpatients also, using the 4/5 F-catheter, which saves hospital charges. Impressive examples show the advantages of i.a. DSA. (orig.) [de

  18. A hybrid data acquisition system for magnetic measurements of accelerator magnets

    International Nuclear Information System (INIS)

    Wang, X.; Hafalia, R.; Joseph, J.; Lizarazo, J.; Martchevsky, M.; Sabbi, G.L.

    2011-01-01

    A hybrid data acquisition system was developed for magnetic measurement of superconducting accelerator magnets at LBNL. It consists of a National Instruments dynamic signal acquisition (DSA) card and two Metrolab fast digital integrator (FDI) cards. The DSA card records the induced voltage signals from the rotating probe while the FDI cards records the flux increment integrated over a certain angular step. This allows the comparison of the measurements performed with two cards. In this note, the setup and test of the system is summarized. With a probe rotating at a speed of 0.5 Hz, the multipole coefficients of two magnets were measured with the hybrid system. The coefficients from the DSA and FDI cards agree with each other, indicating that the numerical integration of the raw voltage acquired by the DSA card is comparable to the performance of the FDI card in the current measurement setup.

  19. The operational procedure of an electron beam accelerator

    International Nuclear Information System (INIS)

    Lee, Byung Cheol; Choi, Hwa Lim; Yang, Ki Ho; Han, Young Hwan; Kim, Sung Chan

    2008-12-01

    The KAERI(Korea Atomic Energy of Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV, has provided irradiation services to users in industries, universities, and institute in various fields. This manual is for the operation of an electron beam which is established in KAERI, and describes elementary operation procedures of electron beam between 0.3 Mev and 10 MeV. KAERI Electron Accelerator facility(Daejeon, Korea) consists of two irradiators: one is a low-energy electron beam irradiator operated by normal conducting RF accelerator, the other is medium-energy irradiator operated by superconducting RF accelerator. We explain the check points of prior to operation, operation procedure of this facility and the essential parts of electron beam accelerator

  20. The operational procedure of an electron beam accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Cheol; Choi, Hwa Lim; Yang, Ki Ho; Han, Young Hwan; Kim, Sung Chan

    2008-12-15

    The KAERI(Korea Atomic Energy of Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV, has provided irradiation services to users in industries, universities, and institute in various fields. This manual is for the operation of an electron beam which is established in KAERI, and describes elementary operation procedures of electron beam between 0.3 Mev and 10 MeV. KAERI Electron Accelerator facility(Daejeon, Korea) consists of two irradiators: one is a low-energy electron beam irradiator operated by normal conducting RF accelerator, the other is medium-energy irradiator operated by superconducting RF accelerator. We explain the check points of prior to operation, operation procedure of this facility and the essential parts of electron beam accelerator.

  1. Diagnostic value of digital subtraction angiography (DSA) using TOSHIBA DIGIFORMER X in the cerebrospinal vascular diseases

    International Nuclear Information System (INIS)

    Ishikawa, Tatsuya; Nakagawa, Yoku; Sawamura, Yutaka; Kobayashi, Nobuaki; Nagashima, Masafumi; Kitaoka, Ken-ichi; Kitagawa, Michio; Itoh, Terufumi; Ohsato, Takao.

    1987-01-01

    Using TOSHIBA Digiformer X, digital subtraction angiography (DSA) was performed in 286 patients, in whom 229 patients of cerebro-spinal vascular disease was included. The authors emphasize the usefulness of DSA in cerebro-spinal vascular disease in relation to conventional angiography. DSA taken by single small dose injection of contrast medium into the ascending aorta clearly demonstrates not only aortic arch and thoracic major vessels, but also cervical vessels and all intracranial vessels. Therefore, we could rapidly understand gross dynamics of the circulation and obtain useful informations prior to catheterization to the selective artery. This advantage of DSA was particularly useful for occlusive vascular diseases. Gradual injection of small dose of contrast medium obviously reduced recoiling of the catheter tip, which enabled the selective angiography with setting of the tip of the catheter at the entrance of cervical major vessels without its sufficient inserion into the selective vessels. This advantage is particularly beneficial for the patients with severe arteriosclerosis who was found to be difficult for selective catheterization. In our experience, demonstration of a presence of aneurysm by DSA was possible in almost all cases of subarachnoid hemorrhage, although spatial resolution of DSA is said to be inferior to the conventional angiography. Real time display of DSA decreased the time required for examination and enabled repeated angiography. This advantage of DSA is especially useful for the patients with spinal arterio-venous malformation and thoracic outlet syndrome. (author)

  2. Clinical application of DSA and evaluation of its methods

    International Nuclear Information System (INIS)

    Ouyang, Yong; Ma, Heping; Gu, Shubing; Zhou, Qunhui; Zhang, Shulan; Liu, Pengzni; Zhang, Junyi.

    1990-01-01

    A total of 160 patients of two hospitals received 192 DSA examinations with different contrast administrations, and techniques of performing DSA were analyzed, compared, and evaluated with reference to the literature. It was concluded that (1) the peripheral injection of contrast material for IVDSA via cannula is simpler than that via a short catheter, but the incidences of contrast extravasation in both cases are higher than with central injection. (2) Both the lower part of the superior vena cava and the right atrial cavity are safe sites for central injection. With central injection for IVDSA, the arterial iodine concentration is approximately double that of peripheral injection, and consistent high quality examinations of the intracranial vessels may be obtained. However, neither peripheral nor central injections can visualize the small vessels clearly. (3) IVDSA may be substituted for conventional angiography only in examinations of the aorta and its main branches. (4) IADSA is becoming a superior angiographic technique and its clinical application is increasing. In addition, means of avoiding contrast extravasation during IVDSA and the main points of selecting the optimal technique for DSA are described in this paper. (author)

  3. Krylov Iterative Methods and the Degraded Effectiveness of Diffusion Synthetic Acceleration for Multidimensional SN Calculations in Problems with Material Discontinuities

    International Nuclear Information System (INIS)

    Warsa, James S.; Wareing, Todd A.; Morel, Jim E.

    2004-01-01

    A loss in the effectiveness of diffusion synthetic acceleration (DSA) schemes has been observed with certain S N discretizations on two-dimensional Cartesian grids in the presence of material discontinuities. We will present more evidence supporting the conjecture that DSA effectiveness will degrade for multidimensional problems with discontinuous total cross sections, regardless of the particular physical configuration or spatial discretization. Fourier analysis and numerical experiments help us identify a set of representative problems for which established DSA schemes are ineffective, focusing on diffusive problems for which DSA is most needed. We consider a lumped, linear discontinuous spatial discretization of the S N transport equation on three-dimensional, unstructured tetrahedral meshes and look at a fully consistent and a 'partially consistent' DSA method for this discretization. The effectiveness of both methods is shown to degrade significantly. A Fourier analysis of the fully consistent DSA scheme in the limit of decreasing cell optical thickness supports the view that the DSA itself is failing when material discontinuities are present in a problem. We show that a Krylov iterative method, preconditioned with DSA, is an effective remedy that can be used to efficiently compute solutions for this class of problems. We show that as a preconditioner to the Krylov method, a partially consistent DSA method is more than adequate. In fact, it is preferable to a fully consistent method because the partially consistent method is based on a continuous finite element discretization of the diffusion equation that can be solved relatively easily. The Krylov method can be implemented in terms of the original S N source iteration coding with only slight modification. Results from numerical experiments show that replacing source iteration with a preconditioned Krylov method can efficiently solve problems that are virtually intractable with accelerated source iteration

  4. The Advanced Composition Explorer Shock Database and Application to Particle Acceleration Theory

    Science.gov (United States)

    Parker, L. Neergaard; Zank, G. P.

    2015-01-01

    The theory of particle acceleration via diffusive shock acceleration (DSA) has been studied in depth by Gosling et al. (1981), van Nes et al. (1984), Mason (2000), Desai et al. (2003), Zank et al. (2006), among many others. Recently, Parker and Zank (2012, 2014) and Parker et al. (2014) using the Advanced Composition Explorer (ACE) shock database at 1 AU explored two questions: does the upstream distribution alone have enough particles to account for the accelerated downstream distribution and can the slope of the downstream accelerated spectrum be explained using DSA? As was shown in this research, diffusive shock acceleration can account for a large population of the shocks. However, Parker and Zank (2012, 2014) and Parker et al. (2014) used a subset of the larger ACE database. Recently, work has successfully been completed that allows for the entire ACE database to be considered in a larger statistical analysis. We explain DSA as it applies to single and multiple shocks and the shock criteria used in this statistical analysis. We calculate the expected injection energy via diffusive shock acceleration given upstream parameters defined from the ACE Solar Wind Electron, Proton, and Alpha Monitor (SWEPAM) data to construct the theoretical upstream distribution. We show the comparison of shock strength derived from diffusive shock acceleration theory to observations in the 50 keV to 5 MeV range from an instrument on ACE. Parameters such as shock velocity, shock obliquity, particle number, and time between shocks are considered. This study is further divided into single and multiple shock categories, with an additional emphasis on forward-forward multiple shock pairs. Finally with regard to forward-forward shock pairs, results comparing injection energies of the first shock, second shock, and second shock with previous energetic population will be given.

  5. CO2-DSA in lower extremity veins: a clinical application

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; Liu Zhensheng; Li Guozhao; Ding Huijuan; Shen Zhiping; He Shicheng; Deng Gang; Fang Wen

    2005-01-01

    Objective: To explore the feasibility and usefulness of carbon dioxide digital subtraction angiography (CO 2 -DSA) in deep veins of lower extremity via the dorsal is pedis vein. Methods: CO 2 -DSA in lower extremity veins was performed in 15 patients (15 limbs affected, male 9, female 6) by injection of CO 2 via the dorsal is pedis vein. Among them, 8 patients were suspected with deep venous thrombosis (DVT), 6 patients with saphena magna dilation, and 1 patient with a follow-up after thrombolysis due to DVT. Results: Excellent image was obtained in 12 cases, which showed branches of the venous system clearly, as well as the details of DVT. Good image was obtained in 2 cases. Technical failure was encountered in one patient due to inaccessible puncture veins. Mild discomfort (transient pain at the percutaneous site) during the procedure was demonstrated in 11 patients. There was no severe side effects or complications in this series. Conclusion: CO 2 -DSA in lower extremity veins is feasible and safe, the preliminary result is satisfactory. (authors)

  6. Status report on the accelerators operation

    International Nuclear Information System (INIS)

    Biri, S.; Kormany, Z.; Berzi, I.; Racz, R.

    2011-01-01

    During 2011 our particle accelerators operated as scheduled, safely and without major or long breakdowns. The utilization rates of the accelerators were similar to the preceding year. The cyclotron delivered 1735 hours and the 40- years old 5 MeV Van de Graaff generator supplied more than 1900 hours. The 1 MeV Van de Graaff accelerator was also operated for several short basic physics experiments last year (84 hours) with requests for much more beamtime in 2012. The plasma and beam-on-target time at the ECR ion source was less than in previous years (322 hours) due to several time consuming technical developments in this laboratory. The isotope separator, as ion beam accelerator was utilized only for a few hours in 2011, since the research and development in this lab focused on other fields. Nevertheless it is continuously available for research requiring special deposition techniques and for isotope tracing studies. After judging and accepting the importance and quality of our accelerators and staff the title 'Strategic Research Infrastructure' was addressed to the Accelerator Center by the Hungarian authorities. In order to get access to the accelerators a new system was introduced. The beamtime (within the frames of the capacities) is available for everyone with equal chance if an acceptable scientific program is provided together with the request. The users have to contact our Program Advisory Committee (PAC). Since last year the requests - both from external or local users - must be delivered by filling out and e-sending on on-line form available in the homepage of the institute. In the next sub-chapters the 2011 operation and development details at the cyclotron, VdG-5 and ECR accelerators are summarized. Cyclotron operation. The operation of the cyclotron in 2011 was concentrated to the usual 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 2603 hours; the time used for systematic

  7. DSA findings and bronchial arterial embolization of bronchiectasis with massive hemoptysis

    International Nuclear Information System (INIS)

    Xu Guobin; Liu Junfang; Hu Jinxiang; Long Qingyun

    2008-01-01

    Objective: To explore DSA findings curative measures and effects of bronchial arterial embolization (BAE)of bronchiectasis with massive hemoptysis. Methods: 35 patients with massive hemoptysis due to bronchiectasis were performed selective bronchial arterial DSA and BAE referring to image data of chest plain film and CT. Embolic materials were polyvinyl alcohol (PVA)and/or gelatinum sponge particles. Curative effects were followed-up for 3 months to 3 years. Results: (1)DSA revealed bronchial artery as being the only abnormal vessel accounted for 74.3%, bronchial artry combined with nonbronchial systemic artery as 22.9% and only non-bronchial artery involved 2.9%. Abnormal vessel number was 1-5 (mean 1.8) per case; Direct and indirect bleeding sign was displayed as 25.7% and 100% respectively. (2)Curative and embolization effects were shown as 61 target vessels of 34 patients being embolized and total effective rate reaching 85.3%; of which 16 cases were adopted super-selective technique, 1 case was failure of stopping bleeding for two times within 3 days, 4 cases recurred within 3 months and 2 cases recurred over 3 months; with recurrent rate of 20.6%, but no serious complications such as spinal cord injury. Conclusions: DSA examination and selective BAE of bronchiectasis with massive hemoptysis could provide high positive angiographic features and reliable curative effect. (authors)

  8. Benign Prostatic Hyperplasia: Cone-Beam CT in Conjunction with DSA for Identifying Prostatic Arterial Anatomy.

    Science.gov (United States)

    Wang, Mao Qiang; Duan, Feng; Yuan, Kai; Zhang, Guo Dong; Yan, Jieyu; Wang, Yan

    2017-01-01

    Purpose To describe findings in prostatic arteries (PAs) at digital subtraction angiography (DSA) and cone-beam computed tomography (CT) that allow identification of benign prostatic hyperplasia and to determine the value added with the use of cone-beam CT. Materials and Methods This retrospective single-institution study was approved by the institutional review board, and the requirement for written informed consent was waived. From February 2009 to December 2014, a total of 148 patients (mean age ± standard deviation, 70.5 years ± 14.5) underwent DSA of the internal iliac arteries and cone-beam CT with a flat-detector angiographic system before they underwent prostate artery embolization. Both the DSA and cone-beam CT images were evaluated by two interventional radiologists to determine the number of independent PAs and their origins and anastomoses with adjacent arteries. The exact McNemar test was used to compare the detection rate of the PAs and the anastomoses with DSA and with cone-beam CT. Results The PA anatomy was evaluated successfully by means of cone-beam CT in conjunction with DSA in all patients. Of the 296 pelvic sides, 274 (92.6%) had only one PA. The most frequent PA origin was the common gluteal-pudendal trunk with the superior vesicular artery in 118 (37.1%), followed by the anterior division of the internal iliac artery in 99 (31.1%), and the internal pudendal artery in 77 (24.2%) pelvic sides. In 67 (22.6%) pelvic sides, anastomoses to adjacent arteries were documented. The numbers of PA origins and anastomoses, respectively, that could be identified were significantly higher with cone-beam CT (301 of 318 [94.7%] and 65 of 67 [97.0%]) than with DSA (237 [74.5%] and 39 [58.2%], P < .05). Cone-beam CT provided essential information that was not available with DSA in 90 of 148 (60.8%) patients. Conclusion Cone-beam CT is a useful adjunctive technique to DSA for identification of the PA anatomy and provides information to help treatment planning

  9. Trial lectures for accelerator operators in SPring-8

    International Nuclear Information System (INIS)

    Ohshima, T.

    2004-01-01

    In case of the SPring-8, accelerator operators are working in three shifts of eight hours. They are making the scheduled beam injection to the storage ring, routine measurements of beam parameters such as the COD, the betatron tunes, the bunch current of stored beam and so on. They are keeping watch on operational state every time. In case of something wrong, they will take measures to meet the situation. Newcomer of operator works with an experienced one to learn sequence of the beam injection, how to operate Graphical User Interface and (GUI) so on. In addition, we organise preliminary lectures on accelerator for operators. Topics done in the lectures are RF system, vacuum system, magnet system, monitors, beam diagnostics, accelerator and beamline control system etc. The contents of the lecture can be seen through web browser again and again. It is useful for operators to understand the SPring-8 facility and details of their work because some of them are not familiar with the accelerator field before being an operator of SPring-8. (author)

  10. Operation of the accelerator

    International Nuclear Information System (INIS)

    GANIL Team

    1992-01-01

    The operation of the GANIL accelerator during 1991 and the first half of 1992 is reported. Results obtained with new beams, metallic beams and the first tests with the new injector system using an ECR source installed on a 100 kV platform are also given. Statistics of operation and beam characteristics are presented. The computer control system is also discussed. (K.A.) 7 refs.; 3 figs.; 8 tabs

  11. Survey of DSA-certified digital repositories : Report on the findings in a survey of all DSA-certified digital repositories on investments in and benefits of acquiring the Data Seal of Approval (DSA)

    NARCIS (Netherlands)

    Waterman, Kees-Jan; Sierman, Barbara

    2016-01-01

    The Data Seal of Approval (DSA) has been in use as a certification instrument for trustworthy digital repositories (TDRs) since 2010. By March 2016 some 50 repositories had applied successfully for the seal. Whereas some organizations and repositories have published about their own experiences in

  12. Value of digital angiography as a substitute for film angiography in comparison with DSA

    International Nuclear Information System (INIS)

    Langer, M.; Mitsch, E.; Zwicker, C.; Scholz, A.; Felix, R.; Langer, R.

    1988-01-01

    The authors performed a prospective study to evaluate whether digital angiography (DA) can provide diagnostic image quality to reduce the need for film studies. The study is based on more than 100 arterial DSA examinations that were intra- and interindividually compared with the DA studies of the same arteries. It was demonstrated that DA with the same quantity of contrast medium as DSA is diagnostic in 80% of cases for abdominal, pelvic, and femoral arteries and in 85% for brachial arteries but in only 56% for carotid arteries if an aortic arch injection is performed. For all examinations, image quality with DSA was excellent in 86%, good in 9%, and diagnostic in 5%, with DA, it was excellent in 5%, good in 49%, diagnostic in 22%, and bad in 24% (90% of these were supraaortic studies). The results of this study indicate that it is worth trying a DA study when DSA is nondiagnostic because of artifacts, if a selective intraarterial contrast medium injection can be performed

  13. The internal carotid artery stenosis or occlusion. The evaluation for the posterior communicating artery on DSA and MRA

    International Nuclear Information System (INIS)

    Zhao Yunhui; Gao Xinjiang; Ma Zhubin; Xu Yikai

    2003-01-01

    Objective: To study the changes of the posterior communicating artery in patients with internal carotid artery (ICA) severe stenosis or occlusion on digital subtract angiography (DSA) and magnetic resonance angiography (MRA). Methods: DSA or MRA findings were analyzed in 74 patients with ICA stenosis or occlusion and in 120 persons selected in the control group, who were unremarkable on cerebral DSA or MRA. Results: On DSA, the presence rate of ipsilateral posterior communicating artery (PCoA) between the study group and the control group had no significant difference; on MRA the rate in the study group was significantly higher than the control group (P 0.05). In the study group, the presence rate of PCoA on DSA was significantly higher than that on MRA (P 0.05). The presence rate of PCoA shown no significant difference between the cases with unilateral ICA involved and cases with bilateral ICA involved. Conclusion: The posterior communicating artery is very important to the patients with the internal carotid artery stenosis or occlusion. Its dilatation on DSA and MRA or appearance on MRA shows its compensation. DSA is valuable in the evaluation of the posterior communicating artery. MRA is a noninvasive and functional imaging method for evaluation the posterior communicating artery

  14. Electrochemical treatment of tannery wastewater using DSA electrodes

    International Nuclear Information System (INIS)

    Costa, Carla Regina; Botta, Clarice M.R.; Espindola, Evaldo L.G.; Olivi, Paulo

    2008-01-01

    In this work we studied the electrochemical treatment of a tannery wastewater using dimensionally stable anodes (DSA) containing tin, iridium, ruthenium, and titanium. The electrodes were prepared by thermal decomposition of the polymeric precursors. The electrolyses were performed under galvanostatic conditions, at room temperature. Effects of the oxide composition, current density, and effluent conductivity were investigated, and the current efficiency was calculated as a function of the time for the performed electrolyses. Results showed that all the studied electrodes led to a decrease in the content of both total phenolic compounds and total organic carbon (TOC), as well as lower absorbance in the UV-vis region. Toxicity tests using Daphnia similis demonstrated that the electrochemical treatment reduced the wastewater toxicity. The use of DSA type electrodes in the electrochemical treatment of tannery wastewater proved to be useful since it can promote a decrease in total phenolic compounds, TOC, absorbance, and toxicity

  15. Electrochemical treatment of tannery wastewater using DSA electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Carla Regina [Departamento de Quimica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, CEP 14049-901 Ribeirao Preto, SP (Brazil); Botta, Clarice M.R.; Espindola, Evaldo L.G. [Nucleo de Estudos em Ecossistemas Aquaticos, Centro de Recursos Hidricos e Ecologia Aplicada, Escola de Engenharia de Sao Carlos, Universidade de Sao Paulo, CP 292, CEP 13560-970 Sao Carlos, SP (Brazil); Olivi, Paulo [Departamento de Quimica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, CEP 14049-901 Ribeirao Preto, SP (Brazil)], E-mail: olivip@ffclrp.usp.br

    2008-05-01

    In this work we studied the electrochemical treatment of a tannery wastewater using dimensionally stable anodes (DSA) containing tin, iridium, ruthenium, and titanium. The electrodes were prepared by thermal decomposition of the polymeric precursors. The electrolyses were performed under galvanostatic conditions, at room temperature. Effects of the oxide composition, current density, and effluent conductivity were investigated, and the current efficiency was calculated as a function of the time for the performed electrolyses. Results showed that all the studied electrodes led to a decrease in the content of both total phenolic compounds and total organic carbon (TOC), as well as lower absorbance in the UV-vis region. Toxicity tests using Daphnia similis demonstrated that the electrochemical treatment reduced the wastewater toxicity. The use of DSA type electrodes in the electrochemical treatment of tannery wastewater proved to be useful since it can promote a decrease in total phenolic compounds, TOC, absorbance, and toxicity.

  16. Operating Characteristics of the low energy accelerator

    International Nuclear Information System (INIS)

    Abd El-Baki, M.M.; Abd El-Rahman, M.M.

    2000-01-01

    The main purpose of this work is to describe the construction and operation of low energy accelerator with energy in the range from (zero to 100 KeV.). This accelerator includes an ion source of the cold cathode penning type (with pierce geometry for ion beam extraction), an accelerating tube (with 8 electrodes) and faraday cup for measuring ion current. A vacuum system which gives vacuum of the order 3.0 x 10 8 torr is used. A palladium tube is used to supply the source with pure hydrogen atoms. It was possible to operate this accelerator with an energy 50 KeV. at minimum hydrogen pressure. 6.3 x 10 6 torr. The total resistance applied between the accelerating electrodes R T = 31.5 M OMEGA. These data includes the influence of the pressure in the accelerating tube, the magnetic field of the ion source, the extraction potential and the accelerating potential on the collector ion current. It was possible to accelerate protons with an energy 50 KeV with current about 100 MU A at pressure 6.3 x 10 6 Torr, the source magnetic field + 1100 gauss (I B = 2A), the current = 0.4 A and the extraction potential = 10 K. V

  17. Digital Subtraction Angiography (DSA) "Road Map": An Angiographic Tool

    Science.gov (United States)

    Turski, P. A.; Stieghorst, M. F.; Strother, C. M.; Crummy, A. B.; Lieberman, R. P.; Mistretta, C. A.

    1982-12-01

    Continuous Digital subtraction combined with intraarterial injections of contrast medium permits the display of arterial structures during real time fluoroscopy. This DSA "road map" facilitates selective catheterization and has proved useful in interventional procedures.

  18. A comparative study of pulmonary hypoperfusion secondary to cancerous invasion of central pulmonary artery in lung cancer with CT and DSA

    International Nuclear Information System (INIS)

    Guo Dajing; Miao Jingtao; Lu Wusheng; Bai Hongli

    2003-01-01

    Objective: To study CT features of pulmonary hypoperfusion in lung cancer with cancerous invasion of central pulmonary artery (CICPA) and the diagnostic value of CT. Methods: The pre-operative pulmonary DSA and contrast-enhanced spiral CT (including HRCT) findings in 20 cases of lung cancer with CICPA were carried out prospectively and comparatively. On DSA and CT, the distribution and quantitative variation of subpleural terminal pulmonary arterioles (pulmonary vessel signs), the filling degree of lung capillary, the post-contrast density changes of lung parenchyma, and the fluctuations of the time-density curve (pulmonary parenchymal signs) were blindly observed. The CT and DSA findings and their consistence were analyzed statistically. The diagnostic values of CT in secondary pulmonary hypoperfusion in lung cancer with CICPA were evaluated. Results: There were 30 lobar arteries with cancerous invasion among the 20 cases and 90% (27/30) of them presented pulmonary hypoperfusion on DSA. For diagnosing pulmonary hypoperfusion, CT had a sensitivity of 78%(21/27), a specificity of 100% (3/3), and an accuracy of 80%(24/30). There were no statistical correlation between pulmonary hypoperfusion and the degree of central pulmonary artery (CPA) stenosis (r s =0.40, P=0.073). Pulmonary vessel signs on CT had a good consistence with that on DSA (Kappa=0.69, P<0.001), while that of pulmonary parenchymal signs was lower (Kappa=0.37, P=0.011). Conclusion: Pulmonary hypoperfusion is one of the common findings in lung cancer with CICPA. CT is of great value in qualitative diagnosis on it, while for quantitative diagnosis, its value is limited to a certain degree

  19. [2011 Shanghai customer satisfaction report of DSA/X-ray equipment's after-service].

    Science.gov (United States)

    Li, Bin; Qian, Jianguo; Cao, Shaoping; Zheng, Yunxin; Xu, Zitian; Wang, Lijun

    2012-11-01

    To improve the manufacturer's medical equipment after-sale service, the fifth Shanghai zone customer satisfaction survey was launched by the end of 2011. The DSA/X-ray equipment was setup as an independent category for the first time. From the survey we can show that the DSA/X-ray equipment's CSI is higher than last year, the customer satisfaction scores of preventive maintenance and service contract are lower than others, and CSI of local brand is lower than imported brand.

  20. INTERSTELLAR PICKUP ION ACCELERATION IN THE TURBULENT MAGNETIC FIELD AT THE SOLAR WIND TERMINATION SHOCK USING A FOCUSED TRANSPORT APPROACH

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Junye; Roux, Jakobus A. le; Arthur, Aaron D. [Department of Space Science, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2016-08-01

    We study the physics of locally born interstellar pickup proton acceleration at the nearly perpendicular solar wind termination shock (SWTS) in the presence of a random magnetic field spiral angle using a focused transport model. Guided by Voyager 2 observations, the spiral angle is modeled with a q -Gaussian distribution. The spiral angle fluctuations, which are used to generate the perpendicular diffusion of pickup protons across the SWTS, play a key role in enabling efficient injection and rapid diffusive shock acceleration (DSA) when these particles follow field lines. Our simulations suggest that variation of both the shape ( q -value) and the standard deviation ( σ -value) of the q -Gaussian distribution significantly affect the injection speed, pitch-angle anisotropy, radial distribution, and the efficiency of the DSA of pickup protons at the SWTS. For example, increasing q and especially reducing σ enhances the DSA rate.

  1. A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks.

    Science.gov (United States)

    Drury, Nicholas; Ramotowski, Robert; Moini, Mehdi

    2018-05-23

    Ambient ionization mass spectrometry is gaining momentum in forensic science laboratories because of its high speed of analysis, minimal sample preparation, and information-rich results. One such application of ambient ionization methodology includes the analysis of writing inks from questioned documents where colorants of interest may not be soluble in common solvents, rendering thin layer chromatography (TLC) and separation-mass spectrometry methods such as LC/MS (-MS) impractical. Ambient ionization mass spectrometry uses a variety of ionization techniques such as penning ionization in Direct Analysis in Real Time (DART), and atmospheric pressure chemical ionization in Direct Sample Analysis (DSA), and electrospray ionization in Desorption Electrospray Ionization (DESI). In this manuscript, two of the commonly used ambient ionization techniques are compared: Perkin Elmer DSA-MS and IonSense DART in conjunction with a JEOL AccuTOF MS. Both technologies were equally successful in analyzing writing inks and produced similar spectra. DSA-MS produced less background signal likely because of its closed source configuration; however, the open source configuration of DART-MS provided more flexibility for sample positioning for optimum sensitivity and thereby allowing smaller piece of paper containing writing ink to be analyzed. Under these conditions, the minimum sample required for DART-MS was 1mm strokes of ink on paper, whereas DSA-MS required a minimum of 3mm. Moreover, both techniques showed comparable repeatability. Evaluation of the analytical figures of merit, including sensitivity, linear dynamic range, and repeatability, for DSA-MS and DART-MS analysis is provided. To the forensic context of the technique, DART-MS was applied to the analysis of United States Secret Service ink samples directly on a sampling mesh, and the results were compared with DSA-MS of the same inks on paper. Unlike analysis using separation mass spectrometry, which requires sample

  2. Status Report on the accelerators operation

    International Nuclear Information System (INIS)

    Biri, S.; Kormany, Z.; Berzi, I.; Racz, R.; Perduk, Z.; Vajda, I.

    2012-01-01

    In 2012 our particle accelerators operated as scheduled, safely and without major or long breakdowns. The utilization rates of the accelerators slightly increased in comparing to the preceding year (see Fig. 1). The cyclotron delivered 1900 hours and the 40-years old 5 MeV Van de Graaff generator supplied more than 2400 hours. The 1 MeV Van de Graaff accelerator was also operated for short basic physics experiments (160 hours). The plasma and beam on-target time at the ECR ion source was similar to the preceding years (410 hours). The isotope separator, as ion beam accelerator was utilized only for a few hours in 2012, since the research and development in this lab focused on other fields. Nevertheless it is continuously available for research requiring special deposition techniques and for isotope tracing studies. We developed the first version of an on-line accelerator status display software. Through our homepage anybody from anywhere can now check the current state of the cyclotron, VdG-5 and ECRIS accelerators. While in 2010 the cyclotron celebrated the 25 th anniversary of its regular starting-up, in 2012 two of our other accelerators had also anniversary. The ECR Ion Source project started 20 years ago, in 1992. To celebrate it, a scientific symposium was hold in September. In the symposium - beyond the high number of audience - the leaders of the Hungarian Academy of Sciences, the University of Debrecen and the City of Debrecen attended, as well. The local and national press reported about the event in many form. A short summary of the symposium is in our homepage (in Hungarian). We had the 40 th anniversary of the regular use of the 5 MeV Van de Graaff accelerator. Having obtained the final approval of the project the 'Electrostatic Accelerator Department' was organized in the Institute in July 1967 with the tasks to perform the planning and construction of the laboratory, to make all the preparations necessary for the intensive scientific use of the

  3. REMOTE OPERATIONS IN A GLOBAL ACCELERATOR NETWORK

    International Nuclear Information System (INIS)

    PEGGS, S.; SATOGATA, T.; AGARWAL, D.; RICE, D.

    2003-01-01

    The INTRODUCTION to this paper summarizes the history of the Global Accelerator Network (GAN) concept and the recent workshops that discussed the relationship between GAN and Remote Operations. The REMOTE OPERATIONS SCENARIOS section brings out the organizational philosophy embodied in GAN-like and to non-GAN-like scenarios. The set of major TOPICS RAISED AT THE WORKSHOPS are only partially resolved. COLLABORATION TOOLS are described and discussed, followed by examples of REMOTE ACCELERATOR CONTROL PROJECTS around the world

  4. Remote operations in a global accelerator network

    International Nuclear Information System (INIS)

    Peggs, Steve; Satogata, Todd; Agarwal, Deborah; Rice, David

    2003-01-01

    The INTRODUCTION to this paper summarizes the history of the Global Accelerator Network (GAN) concept and the recent workshops that discussed the relationship between GAN and Remote Operations. The REMOTE OPERATIONS SCENARIOS section brings out the organizational philosophy embodied in GAN-like and to non-GAN-like scenarios. The set of major TOPICS RAISED AT THE WORKSHOPS are only partially resolved. COLLABORATION TOOLS are described and discussed, followed by examples of REMOTE ACCELERATOR CONTROL PROJECTS around the world

  5. REMOTE OPERATIONS IN A GLOBAL ACCELERATOR NETWORK.

    Energy Technology Data Exchange (ETDEWEB)

    PEGGS,S.; SATOGATA,T.; AGARWAL,D.; RICE,D.

    2003-05-12

    The INTRODUCTION to this paper summarizes the history of the Global Accelerator Network (GAN) concept and the recent workshops that discussed the relationship between GAN and Remote Operations. The REMOTE OPERATIONS SCENARIOS section brings out the organizational philosophy embodied in GAN-like and to non-GAN-like scenarios. The set of major TOPICS RAISED AT THE WORKSHOPS are only partially resolved. COLLABORATION TOOLS are described and discussed, followed by examples of REMOTE ACCELERATOR CONTROL PROJECTS around the world.

  6. Operating experience with the Fermilab 500-GeV accelerator

    International Nuclear Information System (INIS)

    Urban, G.S.; Gannon, J.C.

    1977-01-01

    The Fermilab accelerator has been operating for more than four years. It has been improved so that it is now capable of operating at an energy of 500 GeV and an intensity in excess of 2.0 x 10 13 protons per pulse. The accelerator is manned on a 24 hour a day basis by an operating team of five persons. This is possible in part, because almost all of the hardware systems have status monitoring and control through an advanced computer control system. A discussion is given of the operation of the accelerator with emphasis on person to machine interface, operator training techniques used at Fermilab, and the keeping of records and reliability information

  7. Discontinuous diffusion synthetic acceleration for Sn transport on 2D arbitrary polygonal meshes

    International Nuclear Information System (INIS)

    Turcksin, Bruno; Ragusa, Jean C.

    2014-01-01

    In this paper, a Diffusion Synthetic Acceleration (DSA) technique applied to the S n radiation transport equation is developed using Piece-Wise Linear Discontinuous (PWLD) finite elements on arbitrary polygonal grids. The discretization of the DSA equations employs an Interior Penalty technique, as is classically done for the stabilization of the diffusion equation using discontinuous finite element approximations. The penalty method yields a system of linear equations that is Symmetric Positive Definite (SPD). Thus, solution techniques such as Preconditioned Conjugate Gradient (PCG) can be effectively employed. Algebraic MultiGrid (AMG) and Symmetric Gauss–Seidel (SGS) are employed as conjugate gradient preconditioners for the DSA system. AMG is shown to be significantly more efficient than SGS. Fourier analyses are carried out and we show that this discontinuous finite element DSA scheme is always stable and effective at reducing the spectral radius for iterative transport solves, even for grids with high-aspect ratio cells. Numerical results are presented for different grid types: quadrilateral, hexagonal, and polygonal grids as well as grids with local mesh adaptivity

  8. The electron test accelerator safety in design and operation

    International Nuclear Information System (INIS)

    McKeown, J.

    1980-06-01

    The Electron Test Accelerator is being designed as an experiment in accelerator physics and technology. With an electron beam power of up to 200 kW the operation of the accelerator presents a severe radiation hazard as well as rf and electrical hazards. The design of the safety system provides fail-safe protection while permitting flexibility in the mode of operation and minimizing administrative controls. (auth)

  9. On the importance of effective convergence velocity of synthetic acceleration methods in neutron transport

    International Nuclear Information System (INIS)

    Coppa, G.G.M.; Ravetto, P.; Colombo, V.

    1996-01-01

    The present work concerns some aspects of the optimization of the synthesis acceleration techniques in neutron transport. The importance of non-asymptotic convergence velocity as a theoretical means to characterize and optimize acceleration methods is discussed in detail for isotropic as well as highly anisotropic scattering cases; this shows the innacuracy of results based only on the usual asyptotic analysis. A detailed study of convergence velocity behaviour for space discretized schemes and multidimensional problems is also presented. Finally, various kinds of theoretical-evaluated convergence velocities are reported to study the effective behaviour of some modifications of the classic DSA technique recently proposed to face its loss of effectiveness and optimize performances when dealing with highly anisotropic scattering; comparisons with results of already assessed DSA modification techniques are reported for various scattering cross-section configurations. (Author)

  10. Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Ewen, K.

    1986-01-01

    The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.)

  11. 3D DSA findings of uterine artery and its optimal projection position

    International Nuclear Information System (INIS)

    Lu Weifu; Zhang Aiwu; Zhou Chunze; Lu Dong; Xiao Jingkun; Wang Weiyu; Zhang Xingming; Zhang Zhengfeng; Hou Changlong

    2011-01-01

    Objective: to observe the origin site, anatomic features of uterine artery with 3D DSA and to discuss the optimal projection position in order to improve the success rate of super-selective catheterization of uterine artery. Methods: Prospective pelvic angiography was performed in 42 adult females (a total of 84 uterine arteries). 3D DSA was carried out with 206 ° rotation. 3D reconstruction of the obtained images was performed and the angiographic manifestations of the uterine artery were analyzed. The optimal projection position for the displaying of uterine artery was discussed. The quality of images obtained with the projection angle of 15 °-25 °, 25 °-35 ° and 35 °-45 ° was determined and the results were compared with each other. Results: The orifices of all 84 uterine arteries could be well demonstrated on 3D DSA images. The uterine artery was originated from the anterior trunk of internal iliac artery (n=58, 69%), from main stem of internal iliac artery (n=16, 19.1%), from internal pudenda artery (n=8, 9.5%) and from inferior gluteal artery (n=2, 2.4%). The best projection position to show the opening and route of the uterine artery was contralateral oblique view of 25-35 degrees (P<0.05). Conclusion: 3D DSA can clearly display the anatomy of the uterine artery, which is very helpful for the management of super-selective catheterization of uterine artery. The optimal projection position for uterine artery is contralateral oblique view of 25-35 degrees. (authors)

  12. The placement of naso-jejunal feeding tube under DSA guidance: its technology and skills

    International Nuclear Information System (INIS)

    Song Laichang; Wang Wenhui; Li Fenqiang; Su Dongjun; Li Bo

    2009-01-01

    Objective: To retrospectively analyze and summarize the manipulation and skills of the placement of naso-jejunal feeding tube under DSA guidance. Methods: After performing the spraying anesthesia of nasopharynx, the naso-jejunal feeding tube, with the help of guide wire and under DSA guidance, was placed into the proximal jejunum by passing it through the nose, pharynx, esophagus, stomach, pylorus and duodenum in order. The procedure was employed in 441 cases. Results: The mean time for performing the procedure was within five minutes. The procedure was successfully accomplished in all 441 cases and no complications occurred in this series. Conclusion: Under DSA guidance the placement of naso- jejunal feeding tube can be safely and quickly carried out with high successful rate and less sufferings to patient. It is worth popularizing this technique in clinical practice. (authors)

  13. Development of wide area environment accelerator operation and diagnostics method

    Science.gov (United States)

    Uchiyama, Akito; Furukawa, Kazuro

    2015-08-01

    Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs), the use of standard protocols such as the hypertext transfer protocol (HTTP) is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN) faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  14. Development of wide area environment accelerator operation and diagnostics method

    Directory of Open Access Journals (Sweden)

    Akito Uchiyama

    2015-08-01

    Full Text Available Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs, the use of standard protocols such as the hypertext transfer protocol (HTTP is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  15. Operational experience with compressed geometry acceleration tubes in the Oak Ridge 25URC tandem accelerator

    International Nuclear Information System (INIS)

    Jones, C.M.; Haynes, D.L.; Juras, R.C.; Meigs, M.J.; Ziegler, N.F.

    1989-01-01

    Installation of compressed geometry acceleration tubes and other associated modifications have increased the effective voltage capability of the Oak Ridge 25URC tandem accelerator by about 3 MV. Since mid-September 1988, the accelerator has been operated routinely at terminal potentials up to 24 MV and occasionally near 25 MV. In 3500 hours of full-column operation, including 1100 hours at potentials about 22 MV, no significant spark-included damage was observed. Some considerations related to further improvements in voltage performance are discussed. 7 refs., 5 figs

  16. Transport synthetic acceleration scheme for multi-dimensional neutron transport problems

    Energy Technology Data Exchange (ETDEWEB)

    Modak, R S; Kumar, Vinod; Menon, S V.G. [Theoretical Physics Div., Bhabha Atomic Research Centre, Mumbai (India); Gupta, Anurag [Reactor Physics Design Div., Bhabha Atomic Research Centre, Mumbai (India)

    2005-09-15

    The numerical solution of linear multi-energy-group neutron transport equation is required in several analyses in nuclear reactor physics and allied areas. Computer codes based on the discrete ordinates (Sn) method are commonly used for this purpose. These codes solve external source problem and K-eigenvalue problem. The overall solution technique involves solution of source problem in each energy group as intermediate procedures. Such a single-group source problem is solved by the so-called Source Iteration (SI) method. As is well-known, the SI-method converges very slowly for optically thick and highly scattering regions, leading to large CPU times. Over last three decades, many schemes have been tried to accelerate the SI; the most prominent being the Diffusion Synthetic Acceleration (DSA) scheme. The DSA scheme, however, often fails and is also rather difficult to implement. In view of this, in 1997, Ramone and others have developed a new acceleration scheme called Transport Synthetic Acceleration (TSA) which is much more robust and easy to implement. This scheme has been recently incorporated in 2-D and 3-D in-house codes at BARC. This report presents studies on the utility of TSA scheme for fairly general test problems involving many energy groups and anisotropic scattering. The scheme is found to be useful for problems in Cartesian as well as Cylindrical geometry. (author)

  17. Transport synthetic acceleration scheme for multi-dimensional neutron transport problems

    International Nuclear Information System (INIS)

    Modak, R.S.; Vinod Kumar; Menon, S.V.G.; Gupta, Anurag

    2005-09-01

    The numerical solution of linear multi-energy-group neutron transport equation is required in several analyses in nuclear reactor physics and allied areas. Computer codes based on the discrete ordinates (Sn) method are commonly used for this purpose. These codes solve external source problem and K-eigenvalue problem. The overall solution technique involves solution of source problem in each energy group as intermediate procedures. Such a single-group source problem is solved by the so-called Source Iteration (SI) method. As is well-known, the SI-method converges very slowly for optically thick and highly scattering regions, leading to large CPU times. Over last three decades, many schemes have been tried to accelerate the SI; the most prominent being the Diffusion Synthetic Acceleration (DSA) scheme. The DSA scheme, however, often fails and is also rather difficult to implement. In view of this, in 1997, Ramone and others have developed a new acceleration scheme called Transport Synthetic Acceleration (TSA) which is much more robust and easy to implement. This scheme has been recently incorporated in 2-D and 3-D in-house codes at BARC. This report presents studies on the utility of TSA scheme for fairly general test problems involving many energy groups and anisotropic scattering. The scheme is found to be useful for problems in Cartesian as well as Cylindrical geometry. (author)

  18. Application of DSA and ultrasonic blood rheography (Doppler) to benign paroxysmal positional vertigo

    International Nuclear Information System (INIS)

    Fujita, Nobuya; Wada, Yoshiro; Suzumura, Shigeo; Matsunaga, Takashi

    1990-01-01

    Fourteen cases of benign paroxysmal positional vertigo (BPPV) were studied with cervical circulation using DSA and Doppler. DSA study showed 7 abnormal cases out of 10 cases of BPPV. The abnormal findings included 5 cases of stenosis and 5 cases of coiling and kinking in cervical vertebral arteries. Doppler study showed that vertebral a. and also carotid a. had low volume and high laterality of cervical blood circulation in parameter of flow and velocity. These findings suggest the cervical circulation disorder was one of background factors in pathogenesis of BPPV. (author)

  19. Application of DSA and ultrasonic blood rheography (Doppler) to benign paroxysmal positional vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Nobuya; Wada, Yoshiro; Suzumura, Shigeo; Matsunaga, Takashi (Nara Medical Univ., Kashihara (Japan))

    1990-03-01

    Fourteen cases of benign paroxysmal positional vertigo (BPPV) were studied with cervical circulation using DSA and Doppler. DSA study showed 7 abnormal cases out of 10 cases of BPPV. The abnormal findings included 5 cases of stenosis and 5 cases of coiling and kinking in cervical vertebral arteries. Doppler study showed that vertebral a. and also carotid a. had low volume and high laterality of cervical blood circulation in parameter of flow and velocity. These findings suggest the cervical circulation disorder was one of background factors in pathogenesis of BPPV. (author).

  20. SLAC accelerator operations report: 1995--1997

    International Nuclear Information System (INIS)

    Erickson, R.; Allen, C.W.; Anderson, S.; Linebarger, W.; Stanek, M.

    1997-05-01

    Operational statistics for the linear accelerator programs at SLAC are presented, including run-time records for SLC and the fixed-target programs. Also included are summaries of reliability and maintenance-related statistics

  1. Standard Operating Procedure for Accelerated Corrosion Testing at ARL

    Science.gov (United States)

    2017-11-01

    ARL-TN-0855 ● NOV 2017 US Army Research Laboratory Standard Operating Procedure for Accelerated Corrosion Testing at ARL by... Corrosion Testing at ARL by Thomas A Considine Weapons and Materials Research Directorate, ARL Approved for public...November 2017 2. REPORT TYPE Technical Note 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Standard Operating Procedure for Accelerated

  2. Cosmic Ray Acceleration by a Versatile Family of Galactic Wind Termination Shocks

    Energy Technology Data Exchange (ETDEWEB)

    Bustard, Chad; Zweibel, Ellen G. [Physics Department, University of Wisconsin–Madison, 1150 University Avenue, Madison, WI 53706 (United States); Cotter, Cory, E-mail: bustard@wisc.edu [Department of Astronomy, University of Wisconsin–Madison, 2535 Sterling Hall, 475 N. Charter Street, Madison, WI 53706 (United States)

    2017-01-20

    There are two distinct breaks in the cosmic ray (CR) spectrum: the so-called “knee” around 3 × 10{sup 15} eV and the so-called “ankle” around 10{sup 18} eV. Diffusive shock acceleration (DSA) at supernova remnant (SNR) shock fronts is thought to accelerate galactic CRs to energies below the knee, while an extragalactic origin is presumed for CRs with energies beyond the ankle. CRs with energies between 3 × 10{sup 15} and 10{sup 18} eV, which we dub the “shin,” have an unknown origin. It has been proposed that DSA at galactic wind termination shocks, rather than at SNR shocks, may accelerate CRs to these energies. This paper uses the galactic wind model of Bustard et al. to analyze whether galactic wind termination shocks may accelerate CRs to shin energies within a reasonable acceleration time and whether such CRs can subsequently diffuse back to the Galaxy. We argue for acceleration times on the order of 100 Myr rather than a few billion years, as assumed in some previous works, and we discuss prospects for magnetic field amplification at the shock front. Ultimately, we generously assume that the magnetic field is amplified to equipartition. This formalism allows us to obtain analytic formulae, applicable to any wind model, for CR acceleration. Even with generous assumptions, we find that very high wind velocities are required to set up the necessary conditions for acceleration beyond 10{sup 17} eV. We also estimate the luminosities of CRs accelerated by outflow termination shocks, including estimates for the Milky Way wind.

  3. The Study of Expert System Utilization for the Accelerator Operation

    International Nuclear Information System (INIS)

    Budi-Santosa; Slamet-Santosa; Subari-Santosa

    2000-01-01

    The utilization of expert system in the accelerator laboratory has been studied. The study covers the utilization of expert system in the setting up experiment (tuning parameter), controlling system, safety or warning system. The results study shows, that using the expert system in the accelerator would be easy to operate the accelerator for user and operator. Increasing the skill of expert system could be updated without logical mechanism modification. (author)

  4. Gadolinium-DTPA (Magnevist) as a contrast medium for arterial DSA

    International Nuclear Information System (INIS)

    Schild, H.H.; Weber, W.; Boeck, E.; Mildenberger, P.; Strunk, H.; Dueber, C.; Grebe, P.; Schadmand-Fischer, S.; Thelen, M.

    1994-01-01

    16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2 -0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even large volumes rapidly injected (up to 20 ml/s of the commercially available solution) were well tolerated. DSA with intra-arterial Gd-DTPA seems to be a suitable alternative for vascular imaging if iodine-containing contrast materials are contraindicated. (orig.) [de

  5. Accelerated recovery after cardiac operations.

    Science.gov (United States)

    Kaplan, Mehmet; Kut, Mustafa Sinan; Yurtseven, Nurgul; Cimen, Serdar; Demirtas, Mahmut Murat

    2002-01-01

    The accelerated-recovery approach, involving early extubation, early mobility, decreased duration of intensive care unit stay, and decreased duration of hospitalization has recently become a controversial issue in cardiac surgery. We investigated timing of extubation, length of intensive care unit stay, and duration of hospitalization in 225 consecutive cardiac surgery patients. Of the 225 patients, 139 were male and 86 were female; average age was 49.73 +/- 16.95 years. Coronary artery bypass grafting was performed in 127 patients; 65 patients underwent aortic and/or mitral or pulmonary valvular operations; 5 patients underwent valvular plus coronary artery operations; and in 28 patients surgical interventions for congenital anomalies were carried out. The accelerated-recovery approach could be applied in 169 of the 225 cases (75.11%). Accelerated-recovery patients were extubated after an average of 3.97 +/- 1.59 hours, and the average duration of stay in the intensive care unit was 20.93 +/- 2.44 hours for these patients. Patients were discharged if they met all of the following criteria: hemodynamic stability, cooperativeness, ability to initiate walking exercises within wards, lack of pathology in laboratory investigations, and psychological readiness for discharge. Mean duration of hospitalization for accelerated-recovery patients was 4.24 +/- 0.75 days. Two patients (1.18%) who were extubated within the first 6 hours required reintubation. Four patients (2.36%) who were sent to the wards returned to intensive care unit due to various reasons and 6 (3.55%) of the discharged patients were rehospitalized. Approaches for decreasing duration of intubation, intensive care unit stay and hospitalization may be applied in elective and uncomplicated cardiac surgical interventions with short duration of aortic cross-clamping and cardiopulmonary bypass, without risking patients. Frequencies of reintubation, return to intensive care unit, and rehospitalization are quite

  6. Selective transcervical tubal recanalisation using DSA

    International Nuclear Information System (INIS)

    Kelekis, D.; Fezoulidis, I.; Petsas, T.; Tsapalira, A.; Kelekis, N.

    1991-01-01

    The results of selective transcervical tubal recanalisation by means of a catheter in 20 patients with tubal occlusions are reported and discussed. The advantages of tubal recanalisation under DSA are stressed. In 18 (90%) of the 20 patients treated, it was possible to recanalise at least one tube. Nine of these 18 women (50%) became pregnant during the period of observation, averaging 12 months. Selective transcervical recanalisation of obstructive tubes is a rapid, reliable, cheap and hardly invasive treatment of sterility, when compared with laparoscopy or laparotomy. In the majority of patients it makes surgery unnecessary. (orig.) [de

  7. Indications for intra-arterial digital subtraction angiography (DSA) in vascular disease

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Friedmann, G.; Peters, P.E.; Moedder, U.

    1983-01-01

    Digital subtraction angiography (DSA), using a direct arterial route, diminishes the risk of the examination by reducing the contrast dose by about 75%, making the examination more rapid and making it less likely that catheters will have to be changed. At the same time superimposition is avoided, one of the advantages of selective catheterisation. In view of the low contrast dose, it is possible to carry out several examinations at one time and to use additional projections for intracranial and peripheral disease, thereby improving the diagnostic value of the examination. For certain problems, intra-arterial DSA is already able to replace conventional angiography. The small field size and poor spatial resolution still make conventional angiography necessary as the basic form of investigation in most other circumstances. (orig.) [de

  8. Comparison of CO2 DSA and conventional angiography using non-ionic contrast media in lower extremity angiography

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Park, Sung Jae; Koh, Seok Wan; Seo, Jeong Jin; Kang, Heoung Keun; Chung, Hyon De

    1994-01-01

    The purpose of this study is to compare CO 2 DSA and nonionic contrast media angiography in respect to the quality of the opacification of collaterals and incidence of side-effects in peripheral occlusive arterial disease. Sixteen patients who were suspected to have peripheral occlusive arterial disease were performed angiography with nonionic contrast media and CO 2 at the same location with the same catheter. The causes of the lesions were atherosclerosis(n=7) and Buerger's disease(n=9). CO 2 DSA was compared with nonionic contrast media angiography in respect to the quality of image in the diagnosis of the lesions, opacifications of collaterals and side-effects. In atherosclerosis; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 6 patients and was poor in 1 patient; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 5 patients and was poor in 2 patients. In Buerger's disease; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 2 patients and was poor in 7 patients; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 1 patient and was poor in 8 patients. Leg pain was the only side-effect after CO 2 injection occurring in 4 out of 16 patients. CO 2 could be used as safe contrast media in patient with risk factors for nonionic contrast media and for diagnosis of the atherosclerosis in lower extremity. For the procedures such as vascular intervention requiring large amount of contrast media CO 2 could effectively replace nonionic contrast media

  9. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  10. A theoretical perspective on particle acceleration by interplanetary shocks and the Solar Energetic Particle problem

    Energy Technology Data Exchange (ETDEWEB)

    Verkhoglyadova, Olga P. [Center for Space Plasma and Aeronomic Research, University of Alabama in Huntsville, Huntsville, AL35899 (United States); Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA91109 (United States); Zank, Gary P.; Li, Gang [Department of Space Science, UAH, Huntsville, AL35899 (United States); Center for Space Plasma and Aeronomic Research, University of Alabama in Huntsville, Huntsville, AL35899 (United States)

    2015-02-12

    Understanding the physics of Solar Energetic Particle (SEP) events is of importance to the general question of particle energization throughout the cosmos as well as playing a role in the technologically critical impact of space weather on society. The largest, and often most damaging, events are the so-called gradual SEP events, generally associated with shock waves driven by coronal mass ejections (CMEs). We review the current state of knowledge about particle acceleration at evolving interplanetary shocks with application to SEP events that occur in the inner heliosphere. Starting with a brief outline of recent theoretical progress in the field, we focus on current observational evidence that challenges conventional models of SEP events, including complex particle energy spectra, the blurring of the distinction between gradual and impulsive events, and the difference inherent in particle acceleration at quasi-parallel and quasi-perpendicular shocks. We also review the important problem of the seed particle population and its injection into particle acceleration at a shock. We begin by discussing the properties and characteristics of non-relativistic interplanetary shocks, from their formation close to the Sun to subsequent evolution through the inner heliosphere. The association of gradual SEP events with shocks is discussed. Several approaches to the energization of particles have been proposed, including shock drift acceleration, diffusive shock acceleration (DSA), acceleration by large-scale compression regions, acceleration by random velocity fluctuations (sometimes known as the “pump mechanism”), and others. We review these various mechanisms briefly and focus on the DSA mechanism. Much of our emphasis will be on our current understanding of the parallel and perpendicular diffusion coefficients for energetic particles and models of plasma turbulence in the vicinity of the shock. Because of its importance both to the DSA mechanism itself and to the

  11. Operation of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program

  12. Mesa redonda: Argentina en proyectos globales de investigaciones espaciales y astronómicas. Uso científico de la Antena de Espacio Profundo DSA 3

    Science.gov (United States)

    Colazo, M.

    2016-08-01

    Argentine has 10 percent of the operative time available for the DSA 3 Antenna of the European Space Agency, installed in Malargüe, Mendoza. Here we present the history of the project and the current activities for the scientific use of the antenna.

  13. C-w operation of a 2-MeV RFQ accelerator

    International Nuclear Information System (INIS)

    Cornelius, W.D.

    1986-01-01

    We have achieved reliable cw operation of the Fusion Materials Irradiation Test (FMIT) radio-frequency quadrupole (RFQ) accelerator and have accelerated 40 mA of H 2 + beam to an energy of 2 MeV. The technical considerations for future cw accelerator designs, based on our experience in achieving cw operation, will be presented. Also to be discussed are measurements of beam emittance, matching into the RFQ, and beam transmission through the accelerator. These measurements will be compared with results of theoretical simulations of the device. The diagnostics instrumentation developed for characterizing intense cw beams also will be discussed, as well as the performance of those devices

  14. Operation of the Brookhaven national laboratory accelerator test facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; Van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program. (Author) 5 refs., 4 figs., tab

  15. Cw operation of the FMIT RFQ accelerator

    International Nuclear Information System (INIS)

    Cornelius, W.D.

    1985-01-01

    Recently, we have achieved reliable cw operation of the Fusion Materials Irradiation Test (FMIT) radio-frequency quadrupole (RFQ) accelerator. In addition to the operational experiences in achieving this status, some of the modifications of the vacuum system, cooling system, and rf structure are discussed. Preliminary beam-characterization results are presented. 10 refs., 8 figs

  16. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw [Nicolaus Copernicus University, Department of Radiology and Diagnostic Imaging, Collegium Medicum, Bydgoszcz (Poland); Beuth, Wojciech [University of Humanities and Economics in Wloclawek, Faculty of Health Sciences, Wloclawek (Poland)

    2012-12-15

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 {+-} 19.0 mm{sup 3} in TOF-MRA to 30.5 {+-} 44.6 mm{sup 3} in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization. (orig.)

  17. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA

    International Nuclear Information System (INIS)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw; Beuth, Wojciech

    2012-01-01

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 ± 19.0 mm 3 in TOF-MRA to 30.5 ± 44.6 mm 3 in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization. (orig.)

  18. Experimental research on local renal injury of dog with microwave ablation guided by DSA

    International Nuclear Information System (INIS)

    Lin Jianping; Xian Zhengyuan; Shi Rongshu; Zhang Gaofeng; Li Xianlang

    2008-01-01

    Objective: To explore the efficiency, complications and probability of preserving part renal function by local renal microwave ablation. Methods: The fresh pig renal pelvis full filled with 30% diatrizoate meglumine and the dogs kidney taken arterial pyelography were both ablated with microwave. Dogs were divided into three groups: measuring temperature after ablation group, single point ablation both on the two kidneys group and double points ablation on unilateral kidney group. In measuring temperature after ablation group, DSA and pathology were performed immediately after ablation. In the other groups, DSA with blood and urine samplings were taken for routine tests including renal function right after the ablation and 10 days later. Results: Experiment in vitro showed conspicuous renal pelvic contraction and convolution. The group under power rate of 70, 3 min produced urine leak easily. Preliminary test in vivo with DSA showed the disappearance of local kidney blood supply. The residual renal function was related to areas of necrosis. Acute stage pathology revealed acute renal cortex medulla and pelvic cells injury. DSA of chronic stage showed no change in size of the area of ablation. The blood supply of necrotic areas was not restored. The residual kidney possessed the excretion contrast medium with no urine leaks. Upper pole of right kidney adhered with adjacent tissue, together with thickened covering. Pathology revealed fibrous proliferation around the coagulative necrosis. Conclusion: Microwave ablation can inactivate the local renal tissue, and, effectively preserve the big blood vessels and function of residual kidney. No urine leaks occurred in chronic stage but easily to produce adhesions with adjacent tissue. (authors)

  19. Quasi-steady accelerator operation on the ZAP flow Z-pinch

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, M. C., E-mail: mchugs@uw.edu; Shumlak, U., E-mail: mchugs@uw.edu; Golingo, R. P., E-mail: mchugs@uw.edu; Nelson, B. A., E-mail: mchugs@uw.edu; Ross, M. P., E-mail: mchugs@uw.edu [Aerospace and Energetics Research Program, University of Washington, Seattle, WA 98195 (United States)

    2014-12-15

    The ZaP Flow Z-Pinch Experiment utilizes sheared flows to stabilize an otherwise unstable equilibrium. The sheared flows are maintained by streaming high velocity plasma parallel to the pinch. Previous operations of the machine show depletion of the accelerator’s neutral gas supply late in the pulse leading to pinch instability. The current distribution in the accelerator exhibits characteristic modes during this operation, which is corroborated by interferometric signals. The decrease in density precipitates a loss of plasma quiescence in the pinch, which occurs on a timescale related to the flow velocity from the plasma source. To abate the depletion, the geometry of the accelerator is altered to increase the neutral gas supply. The design creates a standing deflagration front in the accelerator that persists for the pulse duration. The new operating mode is characterized by the same diagnostics as the previous mode. The lessons learned in the accelerator operations have been applied to the design of a new experiment, ZaP-HD. This work was supported by grants from the Department of Energy and the National Nuclear Security Administration.

  20. Primer on theory and operation of linear accelerators in radiation therapy

    International Nuclear Information System (INIS)

    Karzmark, C.J.; Morton, R.J.

    1981-12-01

    This primer is part of an educational package that also includes a series of 3 videotapes entitled Theory and Operation of Linear Accelerators in Radiation Therapy, Parts I, II, and III. This publication provides an overview of the components of the linear accelerator and how they function and interrelate. The auxiliary systems necessary to maintain the operation of the linear accelerator are also described

  1. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with diabetes mellitus and comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Roehrl, Boris; Kunz, Rainer Peter; Oberholzer, Katja; Pitton, Michael Bernhard; Dueber, Christoph; Kreitner, Karl-Friedrich; Neufang, Achim

    2009-01-01

    To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P < 0.001, kappa = 0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa = 0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot. (orig.)

  2. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with diabetes mellitus and comparison with selective intraarterial DSA

    Energy Technology Data Exchange (ETDEWEB)

    Roehrl, Boris; Kunz, Rainer Peter; Oberholzer, Katja; Pitton, Michael Bernhard; Dueber, Christoph; Kreitner, Karl-Friedrich [Johannes Gutenberg University Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Neufang, Achim [Johannes Gutenberg University Mainz, Department of Cardiothoracic and Vascular Surgery, Mainz (Germany)

    2009-12-15

    To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P < 0.001, kappa = 0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa = 0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot. (orig.)

  3. Assessment of chronic thromboembolic pulmonary hypertension by three-dimensional contrast-enhanced MR angiography - comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Ley, S.; Kauczor, H.U.; Kalden, P.; Pitton, M.B.; Thelen, M.; Mayer, E.; Laub, G.

    2000-01-01

    Purpose: This study compares contrast-enhanced 3D-MR angiography (MRA) of the pulmonary arteries with selective intraarterial DSA in patients with chronic thromboembolic pulmonary hypertension. Materials and methods: 20 patients preoperatively underwent a contrast-enhanced 3D-MRA of the pulmonary arteries at 1.5 T using the phased-array body coil. For MRA, we used a 3D-Flash-sequence after bolus timing. 2 radiologists analyzed the acquired image material in consensus with respect to the detection of central thromboembolic material and the visualization of the pulmonary arterial tree. Finally, the MR angiograms were compared with selective DSA images using surgical findings as the definitive standard. Results: MRA demonstrated central thromboembolic material, vessel cut-offs and abnormal proximal-to-distal tapering in all patients. Compared to DSA, MRA depicted the pulmonary vessels up to the segmental level in all cases, it was inferior to DSA in delineation of the subsegmental arteries (sensitivity 87%, specificity 100%). The central beginning of the thromboembolic occlusions seen at MRA corresponded to the beginning of the deobliteration procedure during pulmonary thromboendarterectomy in every case. (orig.) [de

  4. The DSA diagnosis, artery embolization combined with low dose of vasopressin infusion treatment for lower digestive tract hemorrhage

    International Nuclear Information System (INIS)

    Huang Guoxin; Dou Yongchong; Zhang Yanfang; Shen Xinying; Xu Jianmin

    2005-01-01

    Objective: To evaluate the clinical value of digital subtraction angiography (DSA) diagnosis and interventional treatment for lower digestive tract hemorrhage of unknown reasons. Methods: DSA was performed in 32 patients with unknown etiologic lower digestive tract hemorrhage. The locations and causes of hemorrhage were determined by angiography according to the demonstration of contrast medium extravasation, abnormal vasculature and tumor staining. Superselective arterial embolization was performed with retaining catheter of low dose vasopressin infusion for 12 hours of hemostasis. Results: Seventy-five percent of the lesions were identified by DSA with 2 cases of intestinal typhoid, 1 intestinal tuberculosis, 14 cases of vascular malformation and 7 cases of tumor. Hemostasis was succeeded in 20 of 24 patients. The rate of success was 83.3%. Conclusions: DSA and interventional therapy are of great value in diagnosing and treating patients with lower digestive tract hemorrhage of unknown reasons and even those undergone unsuccessful conservative treatment. Low dose vasopressin infusion through retained catheter is safe and efficient after superselective arterial embolization. (authors)

  5. Comparison of hepatic MDCT, MRI, and DSA to explant pathology for the detection and treatment planning of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Lauren M. Ladd

    2016-12-01

    Full Text Available Background/Aims The diagnosis and treatment plan for hepatocellular carcinoma (HCC can be made from radiologic imaging. However, lesion detection may vary depending on the imaging modality. This study aims to evaluate the sensitivities of hepatic multidetector computed tomography (MDCT, magnetic resonance imaging (MRI, and digital subtraction angiography (DSA in the detection of HCC and the consequent management impact on potential liver transplant patients. Methods One hundred and sixteen HCC lesions were analyzed in 41 patients who received an orthotopic liver transplant (OLT. All of the patients underwent pretransplantation hepatic DSA, MDCT, and/or MRI. The imaging results were independently reviewed retrospectively in a blinded fashion by two interventional and two abdominal radiologists. The liver explant pathology was used as the gold standard for assessing each imaging modality. Results The sensitivity for overall HCC detection was higher for cross-sectional imaging using MRI (51.5%, 95% confidence interval [CI]=36.2-58.4% and MDCT (49.8%, 95% CI=43.7-55.9% than for DSA (41.7%, 95% CI=36.2-47.3% (P=0.05. The difference in false-positive rate was not statistically significant between MRI (22%, MDCT (29%, and DSA (29% (P=0.67. The sensitivity was significantly higher for detecting right lobe lesions than left lobe lesions for all modalities (MRI: 56.1% vs. 43.1%, MDCT: 55.0% vs. 42.0%, and DSA: 46.9% vs. 33.9%; all P<0.01. The sensitivities of the three imaging modalities were also higher for lesions ≥2 cm vs. <2 cm (MRI: 73.4% vs. 32.7%, MDCT: 66.9% vs. 33.8%, and DSA: 62.2% vs. 24.1%; all P<0.01. The interobserver correlation was rated as very good to excellent. Conclusion The sensitivity for detecting HCC is higher for MRI and MDCT than for DSA, and so cross-sectional imaging modalities should be used to evaluate OLT candidacy.

  6. Studies on blood supply of liver metastasis with DSA, CT and portal vein perfusion CT during superior mesenteric arterial portography

    International Nuclear Information System (INIS)

    Li Zhigang; Shi Gaofeng; Huang Jingxiang; Li Shunzong; Liang Guoqing; Wang Hongguang; Han Pengyin; Wang Qi; Gu Tieshu

    2008-01-01

    Objective: To probe the blood supply of liver metastasis by celiac artery, proper hepatic artery DSA, portal vein perfusion CT during superior mesenteric arterial portography (PCTAP). Methods: One hundred patients with liver metastases were examined prospectively by plain CT scan, multiphase enhanced CT scan, celiac arteriography and proper hepatic arteriography. Of them, 56 patients were examined by PCTAP. All primary lesions were confirmed by operation and (or) pathology examination. In order to investigate the blood supply of metastasis lesions, the software of Photoshop was used to obtain the time-attenuation curves (TDC) of tumor center, tumor edge, portal vein and normal liver parenchyma adjacent to the tumor to calculate liver perfusion for DSA image analysis, while a deconvolution model from CT perfusion software was designed for the dual blood supply. Results: DSA findings: TDC of proper hepatic arteriography showed: the mean peak concentration (K value) in tumor centers was (67 ± 12)%, and it was (76 ± 15)% for peritumor tissue, (51 ± 10)% in normal liver parenchyma. TDC of celiac arteriogaphy showed that the contrast concentration of tumor centers and tumor edge increased fast in early stage, then maintained a slight upward plateau, in the meanwhile, the contrast concentration of normal liver parenchyma kept increasing slowly. PCTAP findings: tumors exhibited no enhancement during 30 s continued scans. Conclusion: The blood supply of liver metastasis mainly comes from hepatic artery, but barely from portal vein. (authors)

  7. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-12-01

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 ± 19.0 mm(3) in TOF-MRA to 30.5 ± 44.6 mm(3) in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization.

  8. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  9. SLAC accelerator operations report: 1992-1995

    International Nuclear Information System (INIS)

    Erickson, R.; Allen, C.W.; Inman, T.K.; Linebarger, W.; Stanek, M.

    1995-05-01

    Operational statistics for the linear accelerator programs at SLAC are presented, including run-time records for the SLC, FFTB, and fixed target programs. Also included are summaries of reliability and maintenance-related statistics and a discussion of the analysis tools used to study error messages generated by the control system

  10. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2002-05-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination.

  11. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    International Nuclear Information System (INIS)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun

    2002-01-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination

  12. Operational status of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.C.; Fischer, A.S.; Gallardo, J.; Jialin, Xie; Kirk, H.G.; Malone, R.G.; Parsa, Z.; Palmer, R.B.; Rao, T.; Rogers, J.; Sheehan, J.; Tsang, T.Y.F.; Ulc, S.; van Steenbergen, A.; Woodle, M.; Zhang, R.S.; Bigio, I.; Kurnit, N.; Shimada, T.; McDonald, K.T.; Russel, D.P.; Jiang, Z.Y.; Pellegrini, C.; Wang, X.J.

    1990-01-01

    Initial design parameters and early operational results of a 50 MeV high brightness electron linear accelerator are described. The system utilizes a radio frequency electron gun operating at a frequency of 2.856 GHz and a nominal output energy of 4.5 MeV followed by two, 2π/3 mode, disc loaded, traveling wave accelerating sections. The gun cathode is photo excited with short (6 psec) laser pulses giving design peak currents of a few hundred amperes. The system will be utilized to carry out infra-red FEL studies and investigation of new high gradient accelerating structures

  13. [Affine transformation-based automatic registration for peripheral digital subtraction angiography (DSA)].

    Science.gov (United States)

    Kong, Gang; Dai, Dao-Qing; Zou, Lu-Min

    2008-07-01

    In order to remove the artifacts of peripheral digital subtraction angiography (DSA), an affine transformation-based automatic image registration algorithm is introduced here. The whole process is described as follows: First, rectangle feature templates are constructed with their centers of the extracted Harris corners in the mask, and motion vectors of the central feature points are estimated using template matching technology with the similarity measure of maximum histogram energy. And then the optimal parameters of the affine transformation are calculated with the matrix singular value decomposition (SVD) method. Finally, bilinear intensity interpolation is taken to the mask according to the specific affine transformation. More than 30 peripheral DSA registrations are performed with the presented algorithm, and as the result, moving artifacts of the images are removed with sub-pixel precision, and the time consumption is less enough to satisfy the clinical requirements. Experimental results show the efficiency and robustness of the algorithm.

  14. Accelerator/Experiment operations - FY 2006

    Energy Technology Data Exchange (ETDEWEB)

    Brice, S.; Conrad, J.; Denisov, D.; Ginther, G.; Holmes, S.; James, C.; Lee, W.; Louis, W.; Moore, C.; Plunkett, R.; Raja, R.; /Fermilab

    2006-10-01

    This Technical Memorandum (TM) summarizes the Fermilab accelerator and experiment operations for FY 2006. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the FY 2006 Run II at the Tevatron Collider, the MiniBooNE experiments running in the Booster Neutrino Beam in neutrino and antineutrino modes, MINOS using the Main Injector Neutrino Beam (NuMI), and SY 120 activities.

  15. Intravenous spiral CT angiography for assessment before orthotopic liver transplantation: Comparison between tomography, MIP, 3-dimensional surface imaging and intraarterial DSA

    International Nuclear Information System (INIS)

    Hidajat, N.; Vogl, T.J.; Moeller, M.; Bechstein, W.O.; Felix, R.

    1996-01-01

    Purpose: To analyse the efficacy of intravenous spiral CT angiography (SCTA) for the evaluation before orthotopic liver transplantation (oLT) compared with DSA. Methods: Spiral CT was performed on 31 potential recipients of a liver graft in order to examine hepatic vessels, coeliac axis, splenic artery and superior mesenteric artery. The arterial vessels were reconstructed in 'Maximum Intensity Projection (MIP)' and 'Shaded Surface Display (SSD)'-technique. The axial images, MIP and SSD were compared in 25 patients with DSA with regard to the visualisation of the vascular anatomy, detectability of stenosis and vascular diameters. Results: The type of arterial liver supply could be determined via SCTA in all patients. Stenosis of the coeliac axis was seen in ten patients on the DSA, MIP and SSD and in eight patients on the axial images. Occlusion of the hepatic artery was clearly visualised in two patients on the DSA, axial images and MIP and in one patient on the SSD. There was no false positive diagnosis with SCTA. SSD was seen as the best technique to visualise the vessels without overshadowing. There were no significant differences between the diamters measured from the axial images, MIP and SSD images in transversal direction and the DSA images (p>0.05). Conclusion: SCTA is a greatly promising method for the imaging of vessels supplying the liver before oLT, and may convey more diagnostic information than DSA. (orig.) [de

  16. WDS/DSA Certification - International collaboration for a trustworthy research data infrastructure

    Science.gov (United States)

    Mokrane, Mustapha; Hugo, Wim; Harrison, Sandy

    2016-04-01

    , German Institute for Standardization (DIN) standard 31644, Trustworthy Repositories Audit and Certification (TRAC) criteria and the International Organization for Standardization (ISO) standard 16363. In addition, the Data Seal of Approval (DSA) and WDS have set up core certification mechanisms for trusted digital repositories in 2009, which are increasingly recognized as de facto standards. While DSA emerged in Europe in the Humanities and Social Sciences, WDS started as an international initiative with historical roots in the Earth and Space Sciences. Their catalogues of requirements and review procedures are based on the same principles of openness, transparency. A unique feature of the DSA and WDS certification is that it strikes a balance between simplicity, robustness and the effort required to complete. A successful international cross-project collaboration was initiated between WDS and DSA under the umbrella of the Research Data Alliance (RDA), an international initiative started in 2013 to promote data interoperability which provided a useful and neutral forum. A joint working group was established in early 2014 to reconcile and simplify the array of certification options and improve and stimulate core certification for scientific data services. The outputs of this collaboration are a Catalogue of Common Requirements (https://goo.gl/LJZqDo) and a Catalogue of Common Procedures (https://goo.gl/vNR0q1) which will be implemented jointly by WDS and DSA.

  17. Operational experience with the Daresbury accelerator tube

    International Nuclear Information System (INIS)

    Aitken, T.W.; Eastham, D.A.; Joy, T.; Leese, J.M.; Tait, N.R.S.; Thorn, R.

    1986-01-01

    Operational experience with the Daresbury MKI accelerator tube is reviewed with particular attention to conditioning and high voltage performance. The effects of surges and transients on the tube are described and lines of future development are discussed. (orig.)

  18. The application of artificial intelligent techniques to accelerator operations at McMaster University

    Science.gov (United States)

    Poehlman, W. F. S.; Garland, Wm. J.; Stark, J. W.

    1993-06-01

    In an era of downsizing and a limited pool of skilled accelerator personnel from which to draw replacements for an aging workforce, the impetus to integrate intelligent computer automation into the accelerator operator's repertoire is strong. However, successful deployment of an "Operator's Companion" is not trivial. Both graphical and human factors need to be recognized as critical areas that require extra care when formulating the Companion. They include interactive graphical user's interface that mimics, for the operator, familiar accelerator controls; knowledge of acquisition phases during development must acknowledge the expert's mental model of machine operation; and automated operations must be seen as improvements to the operator's environment rather than threats of ultimate replacement. Experiences with the PACES Accelerator Operator Companion developed at two sites over the past three years are related and graphical examples are given. The scale of the work involves multi-computer control of various start-up/shutdown and tuning procedures for Model FN and KN Van de Graaff accelerators. The response from licensing agencies has been encouraging.

  19. The application of artificial intelligent techniques to accelerator operations at McMaster University

    International Nuclear Information System (INIS)

    Poehlman, W.F.S.; Garland, W.J.; Stark, J.W.

    1993-01-01

    In an era of downsizing and a limited pool of skilled accelerator personnel from which to draw replacements for an aging workforce, the impetus to integrate intelligent computer automation into the accelerator operator's repertoire is strong. However, successful deployment of an 'Operator's Companion' is not trivial. Both graphical and human factors need to be recognized as critical areas that require extra care when formulating the Companion. They include interactive graphical user's interface that mimics, for the operator, familiar accelerator controls; knowledge of acquisition phases during development must acknowledge the expert's mental model of machine operation; and automated operations must be seen as improvements to the operator's environment rather than threats of ultimate replacement. Experiences with the PACES Accelerator Operator Companion developed at two sites over the past three years are related and graphical examples are given. The scale of the work involves multi-computer control of various start-up/shutdown and tuning procedures for Model FN and KN Van de Graaff accelerators. The response from licensing agencies has been encouraging. (orig.)

  20. Digital subtraction angiography (DSA) for acute pulmonary emboli

    International Nuclear Information System (INIS)

    Witte, H.; Grabbe, E.; Buecheler, E.

    1983-01-01

    The results of 49 DSAs (in 29 patients) are presented; these were performed for the diagnosis or follow-up of pulmonary emboli. The direct or indirect signs of pulmonary emboli, known to occur during conventional pulmonary angiography, were used as diagnostic criteria. In 47 examinations it was possible to make or to exclude the diagnosis unequivocally. The advantages of DSA make it desirable to use this method as the first form of examination in the diagnosis of acute, but not immediately life-threatening, pulmonary emboli. (orig.) [de

  1. Accelerating and benchmarking operating system functions in a “soft” system

    Directory of Open Access Journals (Sweden)

    Péter Molnár

    2015-06-01

    Full Text Available The todays computing technology provokes serious debates whether the operating system functions are implemented in the best possible way. The suggestions range from accelerating only certain functions through providing complete real-time operating systems as coprocessors to using simultaneously hardware and software implemented threads in the operating system. The performance gain in such systems depends on many factors, so its quantification is not a simple task at all. In addition to the subtleties of operating systems, the hardware accelerators in modern processors may considerably affect the results of such measurements. The reconfigurable systems offer a platform, where even end users can carry out reliable and accurate measurements. The paper presents a hardware acceleration idea for speeding up a simple OS service, its verification setup and the measurement results.

  2. Particle acceleration and reconnection in the solar wind

    Energy Technology Data Exchange (ETDEWEB)

    Zank, G. P.; Hunana, P.; Mostafavi, P.; Le Roux, J. A.; Webb, G. M. [Center for Space Plasma and Aeronomic Research (CSPAR), University of Alabama, Huntsville, AL 35805 (United States); Department of Space Science, University of Alabama, Huntsville, AL 35899 (United States); Khabarova, O. [Heliophysical Laboratory, IZMIRAN, Troitsk, Moscow 142190 (Russian Federation); Cummings, A. C.; Stone, E. C. [California Institute of Technology, Mail Code 290-17, Pasadena, CA 91125 (United States); Decker, R. B. [Johns Hopkins University/Applied Physics Lab., Laurel, MD 20723-6099 (United States)

    2016-03-25

    An emerging paradigm for the dissipation of magnetic turbulence in the supersonic solar wind is via localized quasi-2D small-scale magnetic island reconnection processes. An advection-diffusion transport equation for a nearly isotropic particle distribution describes particle transport and energization in a region of interacting magnetic islands [1; 2]. The dominant charged particle energization processes are 1) the electric field induced by quasi-2D magnetic island merging, and 2) magnetic island contraction. The acceleration of charged particles in a “sea of magnetic islands” in a super-Alfvénic flow, and the energization of particles by combined diffusive shock acceleration (DSA) and downstream magnetic island reconnection processes are discussed.

  3. GAMMA-RAY EMISSION OF ACCELERATED PARTICLES ESCAPING A SUPERNOVA REMNANT IN A MOLECULAR CLOUD

    International Nuclear Information System (INIS)

    Ellison, Donald C.; Bykov, Andrei M.

    2011-01-01

    We present a model of gamma-ray emission from core-collapse supernovae (SNe) originating from the explosions of massive young stars. The fast forward shock of the supernova remnant (SNR) can accelerate particles by diffusive shock acceleration (DSA) in a cavern blown by a strong, pre-SN stellar wind. As a fundamental part of nonlinear DSA, some fraction of the accelerated particles escape the shock and interact with a surrounding massive dense shell producing hard photon emission. To calculate this emission, we have developed a new Monte Carlo technique for propagating the cosmic rays (CRs) produced by the forward shock of the SNR, into the dense, external material. This technique is incorporated in a hydrodynamic model of an evolving SNR which includes the nonlinear feedback of CRs on the SNR evolution, the production of escaping CRs along with those that remain trapped within the remnant, and the broadband emission of radiation from trapped and escaping CRs. While our combined CR-hydro-escape model is quite general and applies to both core collapse and thermonuclear SNe, the parameters we choose for our discussion here are more typical of SNRs from very massive stars whose emission spectra differ somewhat from those produced by lower mass progenitors directly interacting with a molecular cloud.

  4. The periodically pulsed mode of operation of magnet systems in particle accelerators

    International Nuclear Information System (INIS)

    Stange, G.

    1980-01-01

    Since in many applications in particle accelerator technology the beam duty factor, defined by the ratio of beam pulse length to the pulse to pulse period, is very small- typically in the order of 10 - 3 to 10 - 9 - it is interesting to operate the beam optical magnetic system in the periodically pulsed mode as well. Thus, by reducing the average Ohmic losses, it is possible to save energy and material. The pulsed mode of operation of magnet systems is especially adapted to those of linear accelerators and their beam transport systems, since linear accelerators are exclusively operated in this mode. But it is equally suitable for transport systems between cyclic accelerators and large storage rings as they are under development at present. (orig./WL) [de

  5. Carotid DSA based CFD simulation in assessing the patient with asymptomatic carotid stenosis: a preliminary study.

    Science.gov (United States)

    Zhang, Dong; Xu, Pengcheng; Qiao, Hongyu; Liu, Xin; Luo, Liangping; Huang, Wenhua; Zhang, Heye; Shi, Changzheng

    2018-03-12

    Cerebrovascular events are frequently associated with hemodynamic disturbance caused by internal carotid artery (ICA) stenosis. It is challenging to determine the ischemia-related carotid stenosis during the intervention only using digital subtracted angiography (DSA). Inspired by the performance of well-established FFRct technique in hemodynamic assessment of significant coronary stenosis, we introduced a pressure-based carotid arterial functional assessment (CAFA) index generated from computational fluid dynamic (CFD) simulation in DSA data, and investigated its feasibility in the assessment of hemodynamic disturbance preliminarily using pressure-wired measurement and arterial spin labeling (ASL) MRI as references. The cerebral multi-delay multi-parametric ASL-MRI and carotid DSA including trans-stenotic pressure-wired measurement were implemented on a 65-year-old man with asymptomatic unilateral (left) ICA stenosis. A CFD simulation using simplified boundary condition was performed in DSA data to calculate the CAFA index. The cerebral blood flow (CBF) and arterial transit time (ATT) of ICA territories were acquired. CFD simulation showed good correlation (r = 0.839, P = 0.001) with slight systematic overestimation (mean difference - 0.007, standard deviation 0.017) compared with pressure-wired measurement. No significant difference was observed between them (P = 0.09). Though the narrowing degree of in the involved ICA was about 70%, the simulated and measured CAFA (0.942/0.937) revealed a functionally nonsignificant stenosis which was also verified by a compensatory final CBF (fronto-temporal/fronto-parietal region: 51.58/45.62 ml/100 g/min) and slightly prolonged ATT (1.23/1.4 s) in the involved territories, together with a normal left-right percentage difference (2.1-8.85%). The DSA based CFD simulation showed good consistence with invasive approach and could be used as a cost-saving and efficient way to study the relationship between

  6. DSA analysis of the normal and variant hepatic arterial anatomy

    International Nuclear Information System (INIS)

    Lv Penghua; Wang Jie; Shi Haibing; Feng Yaoliang; Chen Huizhu; Chen Yuqin

    2005-01-01

    Objective: To observe and analyze the normal and variant hepatic arterial anatomy by DSA. Methods: One thousand and two hundreds patients with routine celiac and/or selective hepatic arteriography from November 1994 to March 2003 were retrospectively analyzed, some of them were further simultaneously undergone superior mesenteric arteriography, left gastric arteriography or inferior phrenic arteriography etc. Results: 873 (72.8%) patients had the standard hepatic arterial anatomy. 156(13.0%) patients had variant left hepatic arteries (LHAs), 120(10.0%) with variant right hepatic arteries (RHAs) and 21 (1.8%) of a variant anatomy involving both LHA and RHA. The common hepatic artery (CHA) of 1170 (97.5%) patients originated from the celiac artery. 92.0% proper hepatic artery (PHA) was the direct extension of CHA. The RHA was mainly (89.8%) derived from the PHA. There was some variation of the middle hepatic artery (MHA) with more than 62.2% arising from the LHA. The LHA was derived from the PHA (44.6%) or the RHA(30.2%) or other arteries (25.2%). Conclusions: The knowledge of normal and variant anatomy of hepatic vasculature by DSA may be very helpful for intervention therapy and hepatosurgery. (authors)

  7. Improvement in performance and operational experience of 14 UD Pelletron accelerator facility, BARC-TIFR

    International Nuclear Information System (INIS)

    Bhagwat, P.V.

    2002-01-01

    14 UD Pelletron accelerator facility at Mumbai has been operational since 1989. The project MEHIA (Medium Energy Heavy Ion Accelerator) started in 1982 and was formally inaugurated on 30th December 1988. Since then the accelerator has been working round the clock. Improvement in accelerator performance and operational experience are described. (author)

  8. Operation regimes of a dielectric laser accelerator

    Science.gov (United States)

    Hanuka, Adi; Schächter, Levi

    2018-04-01

    We investigate three operation regimes in dielectric laser driven accelerators: maximum efficiency, maximum charge, and maximum loaded gradient. We demonstrate, using a self-consistent approach, that loaded gradients of the order of 1 to 6 [GV/m], efficiencies of 20% to 80%, and electrons flux of 1014 [el/s] are feasible, without significant concerns regarding damage threshold fluence. The latter imposes that the total charge per squared wavelength is constant (a total of 106 per μm2). We conceive this configuration as a zero-order design that should be considered for the road map of future accelerators.

  9. Experiences from the LNPP-P and DSA review. Lessons learned from RBMK safety studies

    International Nuclear Information System (INIS)

    Mankamo, T.; Marttila, J.; Reponen, H.

    2000-09-01

    RBMK is the Russian acronym for 'Channelized Large Power Reactor'. The Soviet-designed RBMK plants deviate substantially from typical Western BWR or PWR plants. The safety of the RBMK plants has raised severe concerns since the major accident at Chernobyl Unit 4 in 1986. In addition, a fire destroyed the turbine hall of Chernobyl Unit 2 in 1991 resulting in a near-accident: the reactor cooling could only be maintained through improvised measures. Another well-known fire event is the control cable room fire at Ignalina Unit 2 in 1989, which led to a partial loss of the main control room functions. After the collapse of Soviet Union several multilateral safety programs were started to evaluate and improve the safety of the RBMK plants. A Probabilistic and Deterministic Safety Assessment (P and DSA) of the Leningrad Nuclear Power Plant (LNPP) Unit 2 was started in 1996. Phase 2 of the project was completed in January 1999. A Peer Review was performed by Russian and Western experts. This report describes the insights from the RBMK risk studies, especially from the LNPP P and DSA with emphasis on the deeper understanding of the risk-important design factors and identification of possible ways to increase safety. LNPP P and DSA has meant a significant progress in this respect. Despite of its certain limitations P and DSA Phase 2 could point out short-term measures, which substantially reduced the risk of identified weaknesses, mostly related to the reliability of the emergency feedwater function and its support systems. The findings of LNPP P and DSA and the review recommendations emphasise the extensions needed to the analysis scope. The spreading and other influences of fires and floods between connected spaces should be analysed because of incomplete separation and protection in these regards in the 16st generation RBMK plants. High priority should be given to the analysis of external hazards, which were found important at the Loviisa NPP on the Northern side of the

  10. Experiences from the LNPP-P and DSA review. Lessons learned from RBMK safety studies

    Energy Technology Data Exchange (ETDEWEB)

    Mankamo, T. [Avaplan Oy (Finland); Marttila, J.; Reponen, H. [Radiation and Nuclear Safety Authority, Helsinki (Finland)

    2000-09-01

    RBMK is the Russian acronym for 'Channelized Large Power Reactor'. The Soviet-designed RBMK plants deviate substantially from typical Western BWR or PWR plants. The safety of the RBMK plants has raised severe concerns since the major accident at Chernobyl Unit 4 in 1986. In addition, a fire destroyed the turbine hall of Chernobyl Unit 2 in 1991 resulting in a near-accident: the reactor cooling could only be maintained through improvised measures. Another well-known fire event is the control cable room fire at Ignalina Unit 2 in 1989, which led to a partial loss of the main control room functions. After the collapse of Soviet Union several multilateral safety programs were started to evaluate and improve the safety of the RBMK plants. A Probabilistic and Deterministic Safety Assessment (P and DSA) of the Leningrad Nuclear Power Plant (LNPP) Unit 2 was started in 1996. Phase 2 of the project was completed in January 1999. A Peer Review was performed by Russian and Western experts. This report describes the insights from the RBMK risk studies, especially from the LNPP P and DSA with emphasis on the deeper understanding of the risk-important design factors and identification of possible ways to increase safety. LNPP P and DSA has meant a significant progress in this respect. Despite of its certain limitations P and DSA Phase 2 could point out short-term measures, which substantially reduced the risk of identified weaknesses, mostly related to the reliability of the emergency feedwater function and its support systems. The findings of LNPP P and DSA and the review recommendations emphasise the extensions needed to the analysis scope. The spreading and other influences of fires and floods between connected spaces should be analysed because of incomplete separation and protection in these regards in the 16st generation RBMK plants. High priority should be given to the analysis of external hazards, which were found important at the Loviisa NPP on the Northern

  11. DSA study of the effect of vasopressin on the small-bowel circulation before and after embolization

    International Nuclear Information System (INIS)

    Li Xueqin; Wang Qiaoxi; Guo Yuxin; Yang Xinhong; Hu Hongyao

    2001-01-01

    Objective: To study the effect of vasopressin (VS) on the small-bowel circulation and the safety of embolotherapy for the small intestinal hemorrhage by DSA. Methods: Ten dogs were divided into three groups. Vasa recta were ligated 30 min after VS infusion ended in group A (n = 4), and 2h after VS infusion ended in group B (n = 4), they were ligated without VS infusion in control group (n = 2). DSA were performed before and after VS infusion, before and after the ligation. The tested parts of intestine were resected to make the pathologic examination a week late. Results: All branches of mesenteric arteries contracted and the contrast developed light in the intestinal wall after VS infusion. Branches contraction recovered but the contrast developed still slight in the intestinal wall about 30 min after infusion ended. All manifestation of DSA recovered to normal 2h after infusion ended. In all groups, the blood vessel net can be seen but is fewer and scattered in the area of ligation. The collocate presented soon after the ligation. The pathologic examination proved that there was only mind mucosal ischemia in all groups. Conclusion: The repressive effect of VS to the circulation of intestine weakened and then disappeared rapidly after the infusion ended. VS infusion had no significant effect on the safety of embolotherapy for small intestinal bleeding when the infusion has been finished for more than 2hr. DSA can demonstrated the circulation state of the intestine before and after embolization

  12. Operation of the APEX photoinjector accelerator at 40 MeV

    International Nuclear Information System (INIS)

    Feldman, D.W.; Bender, S.C.; Byrd, D.A.; Carlsten, B.E.; Early, J.W.; Feldman, R.B.; Goldstein, J.C.; Martineau, R.L.; O'Shea, P.G.; Pitcher, E.J.; Schmitt, M.J.; Stein, W.E.; Wilke, M.D.; Zaugg, T.J.

    1992-01-01

    We have successfully operated the photoinjector and rf linear accelerator for the Los Alamos APEX free electron laser (FEL) at design energy, average macropulse current, and emittance. The accelerator, which operates at 1.3 GHz, consists of a 6 MeV photoinjector and three standing-wave structures with a total beam energy of 40 MeV. This paper presents performance characteristics of the APEX system. The results show that this technology is capable of providing reliable, high-peak current, ultra-high brightness electron beams

  13. Operation and maintenance manual of the accelerator installed in the facility of radiation standards

    International Nuclear Information System (INIS)

    Fujii, Katsutoshi; Kawasaki, Katsuya; Kowatari, Munehiko; Tanimura, Yoshihiko; Kajimoto, Yoichi; Shimizu, Shigeru

    2006-08-01

    4MV Van de Graff accelerator was installed in the Facility of Radiation Standards (FRS) in June 2000, and monoenergetic neutron calibration fields and high energy γ-ray calibration fields have been developed. The calibration fields are provided for R and D on dosimetry, and for the calibration and type-test of radiation protection instruments. This article describes the operational procedure, the maintenance work and the operation of the related apparatuses of the accelerator. This article focuses on the sufficient safety and radiation control for the operators, the maintenance performance of the accelerator, and on the prevention of the malfunction due to the mistakes of the operators. This article targets the unexperienced engineers in charge of operation and maintenance of the accelerator. (author)

  14. Accelerator/Experiment Operations - FY 2015

    Energy Technology Data Exchange (ETDEWEB)

    Czarapata, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); et al.

    2015-10-01

    This Technical Memorandum summarizes the Fermilab accelerator and experiment operations for FY 2015. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the FY 2015 NOvA, MINOS+ and MINERvA experiments using the Main Injector Neutrino Beam (NuMI), the activities in the SciBooNE Hall using the Booster Neutrino Beam (BNB), and the SeaQuest experiment and Meson Test Beam (MTest) activities in the 120 GeV external Switchyard beam (SY120).

  15. Intravenous digital subtraction angiography of the lower limbs combined with field movement (2-field DSA)

    International Nuclear Information System (INIS)

    Fritschy, P.; Terrier, F.

    1988-01-01

    We evaluated a bolus-chase technique designed to reduce the volume of contrast material and to shorten examination time during intravenous digital subtraction angiography (IV-DSA) of the lower limbs. With this technique, after a single injection of contrast material, two contiguous fields can be sequentially imaged (two-field DAS) using a step translated X-ray tube. 67 patients with peripheral vascular disease were studied. All examinations provided diagnostic information, so that in no instance additional intra-arterial injections were required. With the two-field DSA only 3.49 injections were needed in the average for five fields examined in each patient, resulting in a 30% reduction of contrast agent used. (orig.) [de

  16. The application of DSA bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus

    International Nuclear Information System (INIS)

    Ren Chongyang; Di Zhenhai; Mao Xuequn; Zou Rong; Zhang Jian; Wang Meirong; Li Quan

    2010-01-01

    Objective: To retrospectively evaluate the digital subtraction angiography (DSA) bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus. Methods: From January 2004 to March 2010, DSA was performed in forty-five diabetes patients with suspicious vascular diseases of lower extremities. Among them, 24 cases (31 lower limbs)were examined with DSA bolus chase technology and the remaining 21 cases (21 lower limbs)were examined with traditional segmentational technique. The contrast dosage used in angiography, the total exposure time, the examination time and the imaging value for making diagnosis were analyzed and compared between two techniques. Results: For DSA bolus chase technology group, the contrast dosage used in angiography, the total exposure time and the examination time were 25.26 ml, 13.23 s and 37.26 min, respectively,with an average exposure of 101.65 pictures. For traditional segmentational technique group, the contrast dosage used in angiography, the total exposure time and the examination time were 130.00 ml, 52.38 s and 50.48 min, respectively, with an average exposure of 118.33 pictures. The percentage of high quality images in bolus chase technology group and in traditional segmentational technique group were 90.3% and 90.5%, respectively. All the images could meet the requirements for making a reliable diagnosis. Conclusion: Digital subtraction angiography by using bolus-chase technology can well demonstrate the vascular pathology of lower extremities caused by diabetes mellitus, obtain sufficient imaging information necessary for making a reliable diagnosis. DSA bolus chase technology is superior to traditional segmentational technique in shortening procedure time, reducing contrast medium dosage and decreasing radiation dose. (authors)

  17. The operation of accelerators as entrusted business and our company's future plans concerning this tie-up

    International Nuclear Information System (INIS)

    Satoh, Y.; Tanaka, M.

    2004-01-01

    Research Institutes have entrusted the operation of large-scale accelerators to private enterprise in Japan. Research Institutes expect private enterprise to operate and maintain accelerators in a stable condition. With the use of highly advanced accelerators and the diversification of the research to which they are applied, operators of accelerators have come to be considered as supporters of research and are expected to understand the associated highly advanced technologies. In this paper, we are going to consider the present operation of accelerators and discuss our company's future plans concerning this business tie-up. (author)

  18. Two-phase summation imaging using transvenous DSA in subclavian steal syndrome

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1984-01-01

    A simple method is reported to obtain a two-phase summation image in subclavian steal syndrome using digital subtraction angiography (DSA) via selection of a mask during the early arterial phase and the contrast image during delayed retrograde filling of the ipsilateral vertebral artery and the postocclusive subclavian artery. The summation image results by employing replay of the stored image information. (orig.) [de

  19. Radiation transport code with adaptive Mesh Refinement: acceleration techniques and applications

    International Nuclear Information System (INIS)

    Velarde, Pedro; Garcia-Fernaandez, Carlos; Portillo, David; Barbas, Alfonso

    2011-01-01

    We present a study of acceleration techniques for solving Sn radiation transport equations with Adaptive Mesh Refinement (AMR). Both DSA and TSA are considered, taking into account the influence of the interaction between different levels of the mesh structure and the order of approximation in angle. A Hybrid method is proposed in order to obtain better convergence rate and lower computer times. Some examples are presented relevant to ICF and X ray secondary sources. (author)

  20. Imaging of left ventricular wall motion via venous DSA

    International Nuclear Information System (INIS)

    Witte, G.; Roediger, W.; Buecheler, E.; Hamburg Univ.

    1986-01-01

    Until now, angiographical and nuclear medicine examination techniques for imaging left ventricular wall motion have been presenting with difficulties endemic to the methods themselves. For the first time in cardiological diagnostics, digital subtraction angiography (DSA) makes it possible to perform a fairly non-invasive examination with good spatial and temporal resolution. Functional analytic evaluation, however, still demands time-consuming, complicated post-processing. In this article we introduce a method that uses an additive window technique for the immediate generation of wall motion images. (orig.) [de

  1. Safety in design and operation of low energy particle accelerators

    International Nuclear Information System (INIS)

    Badawy, I.

    1991-01-01

    This paper studies the safety in design and operation of low energy accelerators which produce beams of accelerated charged particles and radiations. As radiation sources, the accelerators are widely used in scientific research, industry, food and medical applications. The risks to human and environment are considered. The safety in accelerators is discussed-particularly-the shielding against ionizing radiations, overexposure to RF radiation fire hazards and power failures. Also the paper studies the emergency response at incidents. Emergency procedures are recommended for each type of emergency. Reporting to the competent Authority is also recommended to be prepared for each incident. The basic principles of regulatory control, licensing and inspections for accelerator facilities are discussed. The relation with the competent authority is pointed out. 4 fig

  2. Research on Utilizing a Multivariate Feedback Algorithm to Maintain Stable Operation of Variable Energy Electron Accelerators

    International Nuclear Information System (INIS)

    Van Ausdeln, L.A.; Cordes, G.A.; Haskell, K.J.; Jones, J.L.

    2002-01-01

    Measurements performed utilizing particle accelerators rely on the stability and reproducibility of the accelerator operation, most notably for beam flux (beam current) and beam energy. This can be vital when the measurements rely on previous calibrations performed to establish a standard on which to base the end result of the measurement. The authors have designed a monitoring and control virtual instrument (VI) based on National Instruments LabVIEW TM which calls external modeling code that is written in a standard programming language. The LabVIEWTM virtual instrument allows the user to monitor multiple accelerator parameters while permitting user control of the most important four of these parameters which determine machine operation. The external modeling code, the Advanced Data Validation and Verification System (ADVVS), incorporates as a kernel the Universal Process Model (UPM) software from Triant Technologies, Inc. The kernel executes the accelerator modeling function based on previously acquired history data of the relevant parameters for accelerator operation for conditions of interest. This history data is stored as a reference set prior to subsequent operation. During accelerator operation, 11 accelerator parameters are input to ADVVS from the LabVIEW TM virtual instrument. The ADVVS uses the reference files to predict the eleven parameter values that would normally be expected for optimal accelerator operation. The set of 11 model values is the nearest model state. This multivariate modeling approach presented two principal advantages: 1. The ADVVS allowed rapid detection of anomalous accelerator behavior variant from normal accelerator behavior recorded in the reference set of the kernel. 2. The ADVVS presented a methodology to incrementally tune the accelerator back to optimal operation, thus maintaining highly stable and reproducible operation. In the future, this methodology may also be utilized to tune the accelerator initially or move

  3. The operational experience with 15 UD Pelletron tandem accelerator and its status

    International Nuclear Information System (INIS)

    Joshi, R.; Singh, J.; Singh, P.

    2015-01-01

    IUAC, New Delhi is equipped with many accelerators of different energy ranges. The 15 UD Pelletron tandem accelerator, the first ion accelerator installed, is a heavy ion accelerator and can accelerate almost all the injected negative ions. It has been operational since 1990 and is being used efficiently in different areas of research. The up time of this accelerator has always been better than 95% while the beam on target time has improved from ∼35% in earlier years to more than 60%. In these years, immense efforts have been put in for its operational improvements and better ion beam energies as well as currents. Recently a proper diagnosis was performed to improve its terminal voltage. Regular maintenance of its charging system, accelerating columns and regular unit wise conditioning have improved overall terminal voltage. The conditioning voltage of 15.5 MV was recently achieved and beam tests were performed at 15.1 MV. This has overall improved the performance of accelerator and the stable beam was delivered to user at the maximum terminal potential of 13.9 MV. The 15 UD Pelletron accelerator is also being used regularly as an injector for LINAC. Recently, few problems were encountered, in 15 UD Pelletron, during a routine LINAC operation. Those problems caused lots of beam instability and consequently beam, after boosting the energy from LINAC, was unstable. Proper investigations were carried out and necessary steps were performed in ion source and 15 UD Pelletron accelerator to overcome these problems. Thereafter, stable beam was delivered to user, using LINAC, continuously for around three months. All the efforts done to improve the performance of 15 UD Pelletron as well as to achieve stable beam from LINAC will be discussed. (author)

  4. A DATA-DRIVEN ANALYTIC MODEL FOR PROTON ACCELERATION BY LARGE-SCALE SOLAR CORONAL SHOCKS

    Energy Technology Data Exchange (ETDEWEB)

    Kozarev, Kamen A. [Smithsonian Astrophysical Observatory (United States); Schwadron, Nathan A. [Institute for the Study of Earth, Oceans, and Space, University of New Hampshire (United States)

    2016-11-10

    We have recently studied the development of an eruptive filament-driven, large-scale off-limb coronal bright front (OCBF) in the low solar corona, using remote observations from the Solar Dynamics Observatory ’s Advanced Imaging Assembly EUV telescopes. In that study, we obtained high-temporal resolution estimates of the OCBF parameters regulating the efficiency of charged particle acceleration within the theoretical framework of diffusive shock acceleration (DSA). These parameters include the time-dependent front size, speed, and strength, as well as the upstream coronal magnetic field orientations with respect to the front’s surface normal direction. Here we present an analytical particle acceleration model, specifically developed to incorporate the coronal shock/compressive front properties described above, derived from remote observations. We verify the model’s performance through a grid of idealized case runs using input parameters typical for large-scale coronal shocks, and demonstrate that the results approach the expected DSA steady-state behavior. We then apply the model to the event of 2011 May 11 using the OCBF time-dependent parameters derived by Kozarev et al. We find that the compressive front likely produced energetic particles as low as 1.3 solar radii in the corona. Comparing the modeled and observed fluences near Earth, we also find that the bulk of the acceleration during this event must have occurred above 1.5 solar radii. With this study we have taken a first step in using direct observations of shocks and compressions in the innermost corona to predict the onsets and intensities of solar energetic particle events.

  5. Analytic study of 1D diffusive relativistic shock acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Keshet, Uri, E-mail: ukeshet@bgu.ac.il [Physics Department, Ben-Gurion University of the Negev, POB 653, Be' er-Sheva 84105 (Israel)

    2017-10-01

    Diffusive shock acceleration (DSA) by relativistic shocks is thought to generate the dN / dE ∝ E{sup −p} spectra of charged particles in various astronomical relativistic flows. We show that for test particles in one dimension (1D), p {sup −1}=1−ln[γ{sub d}(1+β{sub d})]/ln[γ{sub u}(1+β{sub u})], where β{sub u}(β{sub d}) is the upstream (downstream) normalized velocity, and γ is the respective Lorentz factor. This analytically captures the main properties of relativistic DSA in higher dimensions, with no assumptions on the diffusion mechanism. Unlike 2D and 3D, here the spectrum is sensitive to the equation of state even in the ultra-relativistic limit, and (for a J(üttner-Synge equation of state) noticeably hardens with increasing 1<γ{sub u}<57, before logarithmically converging back to p (γ{sub u→∞})=2. The 1D spectrum is sensitive to drifts, but only in the downstream, and not in the ultra-relativistic limit.

  6. The dose-area product in DSA

    International Nuclear Information System (INIS)

    Gfirtner, H.

    1995-01-01

    In DSA, the dose-area product shows a very good correlation with the maximum incidence dose. It may therefore serve as a reliable basis for the assessment of radiation doses to patients. The dose-area product is also a useful tool for the detection pf peak shifts in the radiation curves for certain investigations. In view of the considerable scatter of the values for the dose-area product these must, however, be subjected to an additional statistical analysis. Provided that this rule is observed, the dose-area product will considerably gain in importance for the monitoring of radiation exposures of patients. A very noteworthy learning effect could be achieved, if it would be made mandatory for those statistical analyses to be carried out not only on an investigation-specific but also an investigator-specific basis. The latter is particularly true of teaching hospitals. (orig./VHE) [de

  7. Robotic digital subtraction angiography systems within the hybrid operating room.

    Science.gov (United States)

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  8. Operational optimization of large-scale SRF accelerators

    International Nuclear Information System (INIS)

    J. R. Delayen; L. R. Doolittle; C. E. Reece

    1999-01-01

    Unlike other types of accelerator subsystems, because of the flexibility in setting the gradient in each cavity, an SRF linac has many operational degrees of freedom. The overall linac has an operational envelope (beam voltage and current) that depends on acceptable reliability, cryogenic capacity, and RF power budget. For economic and end-user physics reasons, one typically wants to run as close to the edge of the operational envelope as possible. With about 160 cavities in each of the CEBAF linacs. The authors have been forced to treat this problem in a very general way, and satisfy other non-fundamental needs as energy lock and rapid recovery from failures. They present a description of the relevant diverse constraints and the solution developed for CEBAF

  9. The specification and the operation characteristics of the low energy accelerator in JAERI-TRCRE

    International Nuclear Information System (INIS)

    Haruyama, Yasuyuki; Yotsumoto, Keiichi; Okamoto, Jiro

    1993-06-01

    The low energy accelerator system of JAERI TRCRE is of a non scanned type electron accelerator, manufactured by NISSIN HIGH VOLTAGE Co., LTD. The system consists of an oil filled d.c.high voltage generator, semicylindrical acceleration chamber in which a linear cathode is supported coaxially, and the products handling conveyor. The high voltage generator and the acceleration chamber are connected by a flexible cable. A batch irradiation can be carried out using the conveyor in inert gases. The output of the accelerator is 300 kV, 100 mA and the beam width is 60 cm. The specification, the operation procedure, and the operation characteristics of the system are described. (author)

  10. Database automation of accelerator operation

    International Nuclear Information System (INIS)

    Casstevens, B.J.; Ludemann, C.A.

    1982-01-01

    The Oak Ridge Isochronous Cyclotron (ORIC) is a variable energy, multiparticle accelerator that produces beams of energetic heavy ions which are used as probes to study the structure of the atomic nucleus. To accelerate and transmit a particular ion at a specified energy to an experimenter's apparatus, the electrical currents in up to 82 magnetic field producing coils must be established to accuracies of from 0.1 to 0.001 percent. Mechanical elements must also be positioned by means of motors or pneumatic drives. A mathematical model of this complex system provides a good approximation of operating parameters required to produce an ion beam. However, manual tuning of the system must be performed to optimize the beam quality. The database system was implemented as an on-line query and retrieval system running at a priority lower than the cyclotron real-time software. It was designed for matching beams recorded in the database with beams specified for experiments. The database is relational and permits searching on ranges of any subset of the eleven beam categorizing attributes. A beam file selected from the database is transmitted to the cyclotron general control software which handles the automatic slewing of power supply currents and motor positions to the file values, thereby replicating the desired parameters

  11. Radiological safety aspects of the operation of electron linear accelerators

    International Nuclear Information System (INIS)

    Swanson, W.P.

    1979-01-01

    This manual is intended as a guide for the planning and implementation of radiation protection programmes for all types of electron linear accelerators. Material is provided for guidance in the planning and installation stages, as well as for the implementation of radiation protection for continuing operations. Because of their rapidly growing importance, the problems of installation and radiation safety of standard medical and industrial accelerators are discussed in separate sections. Special discussions are devoted to the radiation protection problems unique to electron accelerators: thick-target bremsstrahlung, the electromagnetic cascade, the estimation of secondary-radiation yields from thick targets, and instrumental corrections for accelerator duty factor. In addition, an extensive review of neutron production is given which includes new calculations of neutron production in various materials. A recalculation of activation in a variety of materials has been done for this manual, and specific gamma-ray constants have been recalculated for a number of nuclides to take into account the contribution of K X-rays. The subjects of air and water activation, as well as toxic gas production in air have been specially reviewed. Betatrons and electron microtrons operating at the same energy produce essentially the same kind of secondary radiation as electron linacs and the material given in this manual is directly applicable to them

  12. Accelerator/Experiment Operations - FY 2016

    International Nuclear Information System (INIS)

    Blake, A.; Convery, M.; Geer, S.; Geesaman, D.; Harris, D.; Johnson, D.; Lang, K.; McFarland, K.; Messier, M.; Moore, C. D.; Newhart, D.; Reimer, P. E.; Plunkett, R.; Rominsky, M.; Sanchez, M.; Schmidt, J. J.; Shanahan, P.; Tate, C.; Thomas, J.; Donatella Torretta, Donatella Torretta; Matthew Wetstein, Matthew Wetstein

    2016-01-01

    This Technical Memorandum summarizes the Fermilab accelerator and experiment operations for FY 2016. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the FY 2016 NOvA, MINOS+ and MINERvA experiments using the Main Injector Neutrino Beam (NuMI), the MicroBooNE experiment and the activities in the SciBooNE Hall using the Booster Neutrino Beam (BNB), and the SeaQuest experiment, LArIAT experiment and Meson Test Beam activities in the 120 GeV external switchyard beam (SY120). Each section was prepared by the relevant authors, and was then edited for inclusion in this summary.

  13. Accelerator/Experiment Operations - FY 2016

    Energy Technology Data Exchange (ETDEWEB)

    Blake, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Convery, M. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Geer, S. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Geesaman, D. [Argonne National Lab. (ANL), Argonne, IL (United States); Harris, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Johnson, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Lang, K. [Argonne National Lab. (ANL), Argonne, IL (United States); McFarland, K. [Argonne National Lab. (ANL), Argonne, IL (United States); Messier, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Moore, C. D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Newhart, D. [Fermilab; Reimer, P. E. [Argonne; Plunkett, R. [Fermilab; Rominsky, M. [Fermilab; Sanchez, M. [Iowa State U.; Schmidt, J. J. [Fermilab; Shanahan, P. [Fermilab; Tate, C. [Fermilab; Thomas, J. [University Coll. London; Donatella Torretta, Donatella Torretta [Fermilab; Matthew Wetstein, Matthew Wetstein [Iowa State University

    2016-10-01

    This Technical Memorandum summarizes the Fermilab accelerator and experiment operations for FY 2016. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the FY 2016 NOvA, MINOS+ and MINERvA experiments using the Main Injector Neutrino Beam (NuMI), the MicroBooNE experiment and the activities in the SciBooNE Hall using the Booster Neutrino Beam (BNB), and the SeaQuest experiment, LArIAT experiment and Meson Test Beam activities in the 120 GeV external switchyard beam (SY120). Each section was prepared by the relevant authors, and was then edited for inclusion in this summary.

  14. Database automation of accelerator operation

    International Nuclear Information System (INIS)

    Casstevens, B.J.; Ludemann, C.A.

    1983-01-01

    Database management techniques are applied to automating the setup of operating parameters of a heavy-ion accelerator used in nuclear physics experiments. Data files consist of ion-beam attributes, the interconnection assignments of the numerous power supplies and magnetic elements that steer the ions' path through the system, the data values that represent the electrical currents supplied by the power supplies, as well as the positions of motors and status of mechanical actuators. The database is relational and permits searching on ranges of any subset of the ion-beam attributes. A file selected from the database is used by the control software to replicate the ion beam conditions by adjusting the physical elements in a continuous manner

  15. Operation and reactivity measurements of an accelerator driven subcritical TRIGA reactor

    Science.gov (United States)

    O'Kelly, David Sean

    Experiments were performed at the Nuclear Engineering Teaching Laboratory (NETL) in 2005 and 2006 in which a 20 MeV linear electron accelerator operating as a photoneutron source was coupled to the TRIGA (Training, Research, Isotope production, General Atomics) Mark II research reactor at the University of Texas at Austin (UT) to simulate the operation and characteristics of a full-scale accelerator driven subcritical system (ADSS). The experimental program provided a relatively low-cost substitute for the higher power and complexity of internationally proposed systems utilizing proton accelerators and spallation neutron sources for an advanced ADSS that may be used for the burning of high-level radioactive waste. Various instrumentation methods that permitted ADSS neutron flux monitoring in high gamma radiation fields were successfully explored and the data was used to evaluate the Stochastic Pulsed Feynman method for reactivity monitoring.

  16. Optimization of TW accelerating structures for SLED type modes of operation

    International Nuclear Information System (INIS)

    Le Duff, J.

    1984-02-01

    The SLED method was invented at SLAC in order to produce more electron (and positron) energy from the existing klystrons. The LEP injector LINAC, also now is supposed to operate in the SLED-2 mode. At DESY similar developments have been undertaken too, to improve the linac performances. However in all cases the accelerating sections were not initially optimized for such a mode of operation, and in most cases the designers ended with long accelerating sections making a more efficient use of the klystron power, with rectangular pulses, sometimes at the expense of a longer linac. The present study deals with new approaches for designing linacs, and in particular compact linacs, considering from the beginning a pulse compression scheme, where the main feature consists of having an exponential pulse shape instead of rectangular. Moreover a detailed comparison is made between constant impedance and constant gradient travelling wave (TW) accelerating structures. As a matter of fact the constant impedance structure when optimized looks sligthy better than the second one. In addition short structures appear to be more efficient for a given number of RF sources. Consequently linear accelerators can be made more simple and less expensive, and if one allows for higher tolerable accelerating gradients they can be made even compact

  17. New scheme for the design and operation of proton--proton storage accelerators

    International Nuclear Information System (INIS)

    Claus, J.; Herrera, J.; Humphrey, J.; Marx, M.; Month, M.

    1977-01-01

    A new system is presented for storage accelerating rings which allows many options for operation. During injection, acceleration, and collision, the beams are maintained in the form of azimuthally long bunches. Current is built up in a low-energy, small circumference accumulator ring. Injection into the storage accelerators is carried out with the bunches phased so that they do not collide. The rf buckets can be matched to the incoming long bunches with only a small dilution. Operation of the storage rings consists of: (1) accelerating the formed bunches to any desired energy; and (2) bringing the bunches into collision by relative phasing of the rf in the two rings. This system provides considerable simplification in the design and operation of high energy p-p facilities. For example, it reduces the beam stacking time, relaxes the impedance tolerances relating to longitudinal stability, reduces the aperture utilization, and avoids radiation background problems associated with beam manipulations. A prototype design is considered, using as a basis the parameters of the ISABELLE facility. Performance characteristics and operational procedures are presented. The many advantages related to the machine and experimental aspects are discussed. In particular, cycling the energy during collisions is an interesting option. Lastly, the significance of extending such a facility to higher energy p-p collisions is outlined

  18. Reliability Considerations for the Operation of Large Accelerator User Facilities

    CERN Document Server

    Willeke, F.J.

    2016-01-01

    The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. The article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.

  19. DSA-guided embolization in establishing different canine spinal cord ischemia models and relevant diffusion-weighted imaging study

    International Nuclear Information System (INIS)

    Zhang Jingsong; Sun Lijun; Huan Yi; He Hongde; Zhang Xuexin; Zhao Haitao; Zhang Jing; Zhang Xijing

    2006-01-01

    Objective: To evaluate DSA-guided embolization in establishing different spinal cord ischemia models of canine and relevant diffusion-weighted imaging (DWI) application. Methods: Nine canines were randomly divided into three groups with different matching of lipiodol and diatrizoate meglumine which were injected into bilateral intercostal arteries at 9-11 level guided by DSA monitor. Then observe the changes of motor function and pathologic findings, especially perform routine MRI and DWI by a 1.5 T MR system. Results: Except one case, 8 embolization models were established successfully. Among three groups, slight-group got slight injury and muscle power was about 3-5 grade and range of injury was about two vertebra distance; medium-group presented obvious paraplegia and muscle power was 0-1 grade and range of injury was between 3-4 vertebra distance; severe-group showed greater severity and larger range of injury. All lesions presented high signals at routine MRI and DWI. Conclusion: Using different matching of lipiodol and diatrizoate meglumine can establish different spinal cord ischemia models of canine by DSA- guided embolization and DWI can be performed successfully by 1.5 T MR system, which may be a good method for advanced study of spinal cord ischemia. (authors)

  20. From US NAVY Mate to Division Leader for Operations - Requirements, Development and Career Paths of LANL/LANSCE Accelerator Operators

    International Nuclear Information System (INIS)

    Spickermann, Thomas

    2012-01-01

    There are opportunities for advancement within the team. Operators advance by: (1) Becoming fully qualified - following the LANSCE Accelerator Operator Training Manual, Operator trainees go through 5 levels of qualification, from Radiation Security System to Experimental Area Operator. Must obtain Knowledge and Performance checkouts by an OSS or AOSS, and an End-of-Card checkout by the team leader or RSS engineer (level I). Program was inspired by US NAVY qualification program for nuclear reactor operators. Time to complete: 2-2.5 years. (2) Fully qualified operators are eligible to apply for vacant (OSS)/AOSS positions; and (3) Alternatively, experienced operators can sign up for the voluntary Senior Operator Qualification Program. They must demonstrate in-depth knowledge of all areas of the accelerator complex. Time to complete is 2-3 years (Minimum 4 years from fully qualified). Eligible for promotion to level between qualified operator and AOSS.

  1. Choosing order of operations to accelerate strip structure analysis in parameter range

    Science.gov (United States)

    Kuksenko, S. P.; Akhunov, R. R.; Gazizov, T. R.

    2018-05-01

    The paper considers the issue of using iteration methods in solving the sequence of linear algebraic systems obtained in quasistatic analysis of strip structures with the method of moments. Using the analysis of 4 strip structures, the authors have proved that additional acceleration (up to 2.21 times) of the iterative process can be obtained during the process of solving linear systems repeatedly by means of choosing a proper order of operations and a preconditioner. The obtained results can be used to accelerate the process of computer-aided design of various strip structures. The choice of the order of operations to accelerate the process is quite simple, universal and could be used not only for strip structure analysis but also for a wide range of computational problems.

  2. Carbon dioxide DSA: An alternative to nonionic contrast material

    International Nuclear Information System (INIS)

    Hawkins, I.F.; Siragusa, R.; Mietling, S.; Storm, B.; Hawkins, M.; Hirko, R.; Colella, J.

    1987-01-01

    Over the past 6 years the authors have used CO/sub 2/ with DSA as a contrast agent in over 400 cases for arteriography, venography, portography, and opacification of the biliary and urinary tree. The compressibility of the CO/sub 2/ made consistent delivery difficult. Two injectors were designed which reliably delivered the exact amount of the inexpensive CO/sub 2/ which is required. This improved vascular opacification, collateral filling, and tumor AV shunting without any complications or discomfort. Selective renal artery injections were performed in over 20 patients with renal failure without any increase in creatinine. The authors' experience with animals, patients, and the new injectors are illustrated

  3. Follow-up of intracranial aneurysms treated by a WEB flow disrupter: a comparative study of DSA and contrast-enhanced MR angiography.

    Science.gov (United States)

    Mine, Benjamin; Tancredi, Illario; Aljishi, Ali; Alghamdi, Faisal; Beltran, Margarita; Herchuelz, Maxime; Lubicz, Boris

    2016-06-01

    To compare contrast-enhanced MR angiography (CE-MRA) and DSA for the follow-up of intracranial aneurysms (IAs) treated with the Woven EndoBridge embolization system DL (WEB DL; Sequent Medical, Aliso Viejo, California, USA). We retrospectively identified all patients treated with a WEB DL between November 2010 and February 2013 in 2 hospitals. The IA occlusion was graded on follow-up CE-MRA and DSA by 4 independent readers and by 2 readers reaching a consensus, respectively. Interobserver agreement for MRA and intertechnique agreement was evaluated by calculating linear weighted κ. Fifteen patients with 16 IAs were included. Mean delay between MRA and DSA was 2 months (range 0-16 months). Interobserver agreement for MRA was substantial to almost perfect (κ=0.686-0.921; mean κ=0.809). Intertechnique agreement was moderate to substantial (κ=0.579-0.724; mean κ=0.669). Only three out of five inadequately occluded IAs were detected by MRA. CE-MRA is a useful tool for the follow-up of IAs treated with a WEB DL. However, early follow-up with DSA remains mandatory to detect inadequately occluded IAs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. SEE induced in SRAM operating in a superconducting electron linear accelerator environment

    Science.gov (United States)

    Makowski, D.; Mukherjee, Bhaskar; Grecki, M.; Simrock, Stefan

    2005-02-01

    Strong fields of bremsstrahlung photons and photoneutrons are produced during the operation of high-energy electron linacs. Therefore, a mixed gamma and neutron radiation field dominates the accelerators environment. The gamma radiation induced Total Ionizing Dose (TID) effect manifests the long-term deterioration of the electronic devices operating in accelerator environment. On the other hand, the neutron radiation is responsible for Single Event Effects (SEE) and may cause a temporal loss of functionality of electronic systems. This phenomenon is known as Single Event Upset (SEU). The neutron dose (KERMA) was used to scale the neutron induced SEU in the SRAM chips. Hence, in order to estimate the neutron KERMA conversion factor for Silicon (Si), dedicated calibration experiments using an Americium-Beryllium (241Am/Be) neutron standard source was carried out. Single Event Upset (SEU) influences the short-term operation of SRAM compared to the gamma induced TID effect. We are at present investigating the feasibility of an SRAM based real-time beam-loss monitor for high-energy accelerators utilizing the SEU caused by fast neutrons. This paper highlights the effects of gamma and neutron radiations on Static Random Access Memory (SRAM), placed at selected locations near the Superconducting Linear Accelerator driving the Vacuum UV Free Electron Laser (VUVFEL) of DESY.

  5. Operational status of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Chou, T.S.; Los Alamos National Lab., NM; Princeton Univ., NJ

    1989-01-01

    Design and operation of a 50 MeV Electron Linear Accelerator utilizing a low emittance (γ var epsilon = 5 to 10 mm-mrad) radio frequency gun operating at an output energy of 5 MeV and a charge of 1 nC is described. Design calculations and early radio frequency measurements and operational experience with the electron gun utilizing a dummy copper cathode in place of the proposed photocathode emitter are given. 6 refs., 9 figs., 1 tab

  6. Operational health physics at the Los Alamos meson physics proton accelerator

    International Nuclear Information System (INIS)

    Engelke, M.J.

    1975-01-01

    The operational health physics practices and procedures at the Clinton P. Anderson Los Alamos Meson Physics Facility (LAMPF), a medium energy, high intensity proton accelerator are reviewed. The operational philosophy used for the control of personnel exposures and radioactive materials is discussed. A particular operation involving the removal of a radioactive beam stop reading in excess of 1000 R/h is described

  7. Optimized operation of dielectric laser accelerators: Single bunch

    Directory of Open Access Journals (Sweden)

    Adi Hanuka

    2018-05-01

    Full Text Available We introduce a general approach to determine the optimal charge, efficiency and gradient for laser driven accelerators in a self-consistent way. We propose a way to enhance the operational gradient of dielectric laser accelerators by leverage of beam-loading effect. While the latter may be detrimental from the perspective of the effective gradient experienced by the particles, it can be beneficial as the effective field experienced by the accelerating structure, is weaker. As a result, the constraint imposed by the damage threshold fluence is accordingly weakened and our self-consistent approach predicts permissible gradients of ∼10  GV/m, one order of magnitude higher than previously reported experimental results—with unbunched pulse of electrons. Our approach leads to maximum efficiency to occur for higher gradients as compared with a scenario in which the beam-loading effect on the material is ignored. In any case, maximum gradient does not occur for the same conditions that maximum efficiency does—a trade-off set of parameters is suggested.

  8. Diagnosis of renal artery stenosis : spiral CTA vs. IA-DSA

    International Nuclear Information System (INIS)

    Kim, Tae Sung; Chung, Jin Wook; Park, Jae Hyung; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung

    1996-01-01

    To evaluate the accuracy of spiral CT angiography(CTA) in the demonstration of accessory or multiple renal arteries and renal artery stenosis. We prospectively performed CTA in 50 patients (24 males and 26 females) between nine and 77 years old (mean 39.3) in whom renovascular hypertension was suspected (n=32), or who were potential renal donors (n=18). Within two days of CTA, intraarterial digital subtraction angiography(IA-DSA) was performed. Both spiral CTA and IA-DSA images were blindly compared by two radiologists with respect to the number of accessory renal arteries and the location and severity of renal artery stenosis. The severity of renal arterial stenosis was graded with a five-point scale (grades 0-4). CTA demonstrated 26 of total 27 accessory renal arteries (detection rate=96.5%). For the diagnosis of grade 2-4 stenosis (≥50% stenosis) (n=40 of a total of 127 renal arteries), the sensitivity, specificity, and accuracy of CTA were 90%, 96.5%, and 94.5%, respectively. For the detection of grade 3-4 stenoses (≥75% stenosis) (n=33), the sensitivity, specificity, and accuracy of CTA were 87.9%, 98.9%, and 96.1%, respectively. For the detection of grade 3-4 stenoses in the main renal artery (n=27), the sensitivity, specificity, and accuracy of CTA were 96.3%, 100%, and 99.0%, respectively. Spiral CTA is a reliable and accurate screening modality for the evaluation of renal artery in patients suspected to be suffering from renovascular hypertension, or who are potential renal donors

  9. Hemodynamic study of cervical carotid arteries using DSA

    International Nuclear Information System (INIS)

    Kumashiro, Masayuki; Araki, Osamu; Matsunaga, Morio; Shigeyasu, Makio

    1986-01-01

    Although intravenous digital subtraction angiography (IVDSA) has been widely utilized as a means of morphological examination for the detection of intracranial or extracranial vascular lesions, it has thus for contributed little to quantitative assessment in hemodynamics. In the present study, a fundamental analysis of the hemodynamics on the cervical carotid artery was performed with a relative perfusion efficiency (Rath et al., 1979). This was not related to the measurement of time, such as the mean transit time, but was based on Sapirstein's principle. After the intravenous administration of the contrast material, dynamic DSA was performed using our equipment, Shimadzu DAR-100. After setting the region of interest in common carotid arteries on DSA images by means of a microdensitometer (Sakura PDS-15) combined with a computer (NEC ACOS-460), time-density curves were obtained on both sides. Thereafter, the RPE was calculated as a ratio of two integrals from the zero time to the earlier peak time of the time-density curves with respect to the time. The flow model with the hydro-dynamic system was used to detect the relationship between the RPEs and the ratios of the actual flows in the system. The results of this experiment showed a high correlation between the RPEs and the flows (r = 0.85, p < 0.001). In normal subjects (n = 28), the mean of the RPEs was 1.07 ± 0.27 (S.D.). The RPEs showed significantly lower values in the 5 patients with severe stenosis of the internal carotid artery (0.76 ± 0.15, p < 0.02), as well as even more significantly lower values in the 9 patients with a complete occlusion of the internal carotid artery (0.64 ± 0.19, p < 0.001). The RPE measurement with IVDSA has been shown to be useful for recognizing the cervical hemodynamic changes in patients with occlusive cervicovascular disease. (author)

  10. Successive approximation algorithm for cancellation of artifacts in DSA images

    International Nuclear Information System (INIS)

    Funakami, Raiko; Hiroshima, Kyoichi; Nishino, Junji

    2000-01-01

    In this paper, we propose an algorithm for cancellation of artifacts in DSA images. We have already proposed an automatic registration method based on the detection of local movements. When motion of the object is large, it is difficult to estimate the exact movement, and the cancellation of artifacts may therefore fail. The algorithm we propose here is based on a simple rigid model. We present the results of applying the proposed method to a series of experimental X-ray images, as well as the results of applying the algorithm as preprocessing for a registration method based on local movement. (author)

  11. Radiological safety aspects of the operation of proton accelerators

    International Nuclear Information System (INIS)

    Thomas, R.H.; Stevenson, G.R.

    1988-01-01

    Particle accelerators are finding increased application in both the fundamental and applied sciences and in industry around the world. Positive ion accelerators are being applied in a host of fields, including radiation damage studies, induced activation and dating measurements, radiography, radiotherapy and fusion research. Because these devices can be potent sources of neutrons, it is important that information concerning their safe operation be widely available. This report is conceived as a source book providing authoritative guidance in radioprotection from an important category of radiation sources. It thus supplements other manuals of the IAEA related to the planning and implementation of radiation protection programmes. Refs, figs and tabs

  12. Superconducting linac at Inter-University Accelerator Centre: Operational challenges and solutions

    Directory of Open Access Journals (Sweden)

    S. Ghosh

    2009-04-01

    Full Text Available A superconducting linear accelerator based on niobium quarter wave resonators has recently become operational to boost the energy of the heavy ion beams available from the existing 15 UD (unit doubled Pelletron accelerator. The niobium resonators typically performed at an accelerating field of 3–6  MV/m at 6 watts of input power in the test cryostat. When they were tested in the linac cryostat, the accelerating fields were drastically reduced and a number of other problems were also encountered. At present, all the problems have been diagnosed and solved. Many design modifications, e.g., in power coupler, mechanical tuner, helium cooling system, etc. were incorporated to solve the problems. A novel method of vibration damping was also implemented to reduce the effect of microphonics on the resonators. Finally, the accelerated beam through linac was delivered to conduct experiments.

  13. Environmental-technical aspects of the operation of the accelerator at NIKHEF-K

    International Nuclear Information System (INIS)

    Post, J.C.

    1982-12-01

    This report discusses those technical aspects of the operation of the Medium Energy Accelerator at NIKHEF-K which affect the environment. The accelerator produces an electron beam with a maximum capacity of 300 kW and, as by-products, intense gamma and neutron radiations. These radiations can contaminate components of the accelerator and the direct surroundings. The electron beam can also generate ozone in the air. The accelerator produces a small quantity of radioactive waste itself and research in the chemistry department also leads to the production of radioactive waste. These wastes are stored temporarily and transported for treatment/storage elsewhere in Holland once a year. (Auth.)

  14. The effect of the signal-to-noise ratio and window width on image information in intravenous DSA of various vascular regions

    International Nuclear Information System (INIS)

    Arlart, I.P.; Ertel, R.; Siemens A.G., Erlangen

    1986-01-01

    The diagnostic quality of DSA images depends on numerous factors related to the apparatus and the technique of examination. An improvement in image can be brought about by correct choice of the mask and injected frames, by subsequent correct manipulation of the images and by the choice of the signal-to-noise ratio and window width. In the present study, the effect of these factors was demonstrated on image quality of venous DSA studies in various vascular regions. Practical advice is given for the examination of particular regions and for various diagnostic problems. (orig.)

  15. Clean Slate Environmental Remediation DSA for 10 CFR 830 Compliance

    International Nuclear Information System (INIS)

    James L. Traynor, Stephen L. Nicolosi, Michael L. Space, Louis F. Restrepo

    2006-01-01

    Clean Slate Sites II and III are scheduled for environmental remediation (ER) to remove elevated levels of radionuclides in soil. These sites are contaminated with legacy remains of non-nuclear yield nuclear weapons experiments at the Nevada Test Site, that involved high explosive, fissile, and related materials. The sites may also hold unexploded ordnance (UXO) from military training activities in the area over the intervening years. Regulation 10 CFR 830 (Ref. 1) identifies DOE-STD-1120-98 (Ref. 2) and 29 CFR 1910.120 (Ref. 3) as the safe harbor methodologies for performing these remediation operations. Of these methodologies, DOE-STD-1120-98 has been superseded by DOE-STD-1120-2005 (Ref. 4). The project adopted DOE-STD-1120-2005, which includes an approach for ER projects, in combination with 29 CFR 1910.120, as the basis documents for preparing the documented safety analysis (DSA). To securely implement the safe harbor methodologies, we applied DOE-STD-1027-92 (Ref. 5) and DOE-STD-3009-94 (Ref. 6), as needed, to develop a robust hazard classification and hazards analysis that addresses non-standard hazards such as radionuclides and UXO. The hazard analyses provided the basis for identifying Technical Safety Requirements (TSR) level controls. The DOE-STD-1186-2004 (Ref. 7) methodology showed that some controls warranted elevation to Specific Administrative Control (SAC) status. In addition to the Evaluation Guideline (EG) of DOE-STD-3009-94, we also applied the DOE G 420.1 (Ref. 8) annual, radiological dose, siting criterion to define a controlled area around the operation to protect the maximally exposed offsite individual (MOI)

  16. Brain arteriovenous malformation diagnosis: value of time-resolved contrast-enhanced MR angiography at 3.0T compared to DSA

    International Nuclear Information System (INIS)

    Machet, A.; Kadziolka, K.; Robin, G.; Lanoix, O.; Pierot, L.; Portefaix, C.

    2012-01-01

    This study was conducted in order to evaluate the value of time-resolved contrast-enhanced magnetic resonance angiography (TR-CE-MRA) with a 3.0-T magnetic field compared to digital subtraction angiography (DSA) as the reference standard for the diagnosis of brain arteriovenous malformation (bAVM). Nineteen patients with 19 angiographically confirmed untreated bAVM were investigated with both DSA and TR-CE-MRA for the initial diagnosis. Examinations were compared by two independent readers. Interobserver agreement and intermodality agreement with respect to nidus size, arterial feeders, and venous drainage were determined using the K statistic test. Also, the quality of the TR-CE-MRA images was evaluated. Seventeen of the 19 bAVM (89.5%) detected with DSA were diagnosed with TR-CE-MRA. Interobserver agreement for TR-CE-MRA was good for nidus size, venous drainage, and arterial feeders (K = 0.75, 95% CI 0.50-1.00; K = 0.77, 95% CI 0.54-1.00; and K = 0.80, 95% CI 0.59-1.00 respectively). Intermodality agreement was good for nidus size and venous drainage (K = 0.75, 95% CI 0.49-1.00 and K = 0.77, 95% CI 0.54-1.00, respectively) and moderate for arterial feeders (K = 0.44, 95% CI 0.17-0.70). TR-CE-MRA at 3.0 T has a good sensitivity for bAVM detection and good agreement with DSA for determining nidus size and the type of venous drainage, suggesting that TR-CE-MRA is potentially a reliable tool for the diagnosis and assessment of bAVMs. However, it still suffers from low spatial resolution and vessel superposition, making differentiation of the arterial feeders of the nidus difficult at times. (orig.)

  17. Operating experience with a new accelerator control system based upon microprocessors

    Energy Technology Data Exchange (ETDEWEB)

    Magyary, S.; Lancaster, H.; Selph, F.; Fahmie, M.; Timossi, C.; Glatz, J.; Ritchie, A.; Hinkson, J.; Benjegerdes, R.; Brodzik, D.

    1981-03-01

    This paper describes the design and operating experience with a high performance control system tailored to the requirements of the SuperHILAC accelerator. A large number (20) of the latest 16-bit microcomputer boards are used in a parallel-distributed manner to get a high system bandwidth. Because of the high bandwidth, software costs and complexity are significantly reduced. The system by its very nature and design is easily upgraded and repaired. Dynamically assigned and labeled knobs, together with touch-panels, allow a flexible and efficient operator interface. An X-Y vector graphics system provides for display and labeling of real-time signals as well as general plotting functions. This control system allows attachment of a powerful auxiliary computer for scientific processing with access to accelerator parameters.

  18. Introduction to the principles of Digital Subtraction Angiography (DSA)

    Energy Technology Data Exchange (ETDEWEB)

    Kaplanis, P [Medical Physics Department, Nicosia General Hospital, Nicosia (Cyprus)

    1998-12-31

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author). 5 refs, 3 figs.

  19. Introduction to the principles of Digital Subtraction Angiography (DSA)

    International Nuclear Information System (INIS)

    Kaplanis, P.

    1997-01-01

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author)

  20. Operation of medical accelerator PATRO at Hyogo Ion Beam Medical Center

    International Nuclear Information System (INIS)

    Itano, A.; Akagi, T.; Higashi, A.; Fukushima, S.; Fujita, A.; Honda, Y.; Isa, H.; Nishikigouri, K.

    2004-01-01

    PATRO (Particle Accelerator for Therapy, Radiology and Oncology) is a medical accelerator facility for hadrontherapy of cancer at Hyogo Ion Beam Medical Center (HIBMC). Beam particles are proton (230 MeV) and carbon (320 MeV/u). After the beam commissioning and the tuning of irradiation system in 2000, we performed the clinical trials with proton and carbon beams from May 2001 until July 2002. We operated the accelerator for about 11,000 hours since the beginning of the beam tuning until the end of the clinical trials and for about 5,000 hours during the clinical trials. No serious troubles happened during the clinical trials. The stability and the reproducibility of the beams were well proved. (author)

  1. Operational experience from a large EPICS-based accelerator facility

    International Nuclear Information System (INIS)

    Ciarlette, D.J.; Gerig, R.

    1995-01-01

    The Advanced Photon Source (APS) at Argonne National Laboratory is a third-generation x-ray light source which uses the Experimental Physics and Industrial Control System (EPICS) to operate its linear accelerator, positron accumulator ring, booster synchrotron, and storage ring equipment. EPICS has been used at the APS since the beginning of installation and commissioning. Currently, EPICS controls approximately 100 VME crates containing over 100,000 process variables. With this complexity, the APS has had to review some of the methods originally employed and make changes as necessary. In addition, due to commissioning and operational needs, higher-level operator software needed to be created. EPICS has been flexible enough to allow this

  2. Thermal stabilities and optimal operating parameters for the Oak Ridge Spallation Neutron Source superconducting linear accelerator

    International Nuclear Information System (INIS)

    Kim, Sang-Ho; Campisi, Isidoro E.

    2007-01-01

    The baseline Spallation Neutron Source (SNS) accelerator will provide a 1 GeV, 1.4 MW proton beam to a mercury target for the production of neutrons. The main acceleration for the H- beam is provided by 81 superconducting cavities installed in 23 cryomodules operating at 805 MHz. The design of the superconducting linac includes a 2.1 K, 2.5 kW cryogenic plant to maintain the cavities below the helium lambda point for efficient operation at high accelerating gradients. In this paper operating conditions are analyzed rather than the design ones, which still guarantees a high gradient operation without any temperature constraint. From the analysis it appears that the SNS superconducting linac can be operated at temperatures higher than 2.1 K, a fact resulting from both the pulsed nature of the superconducting cavities, the specific configuration of the existing cryogenic plant and the operating frequency. General conditions are also given regarding the operation of pulsed superconducting cavities resonating at different frequencies

  3. Effects of Alfvénic Drift on Diffusive Shock Acceleration at Weak Cluster Shocks

    Science.gov (United States)

    Kang, Hyesung; Ryu, Dongsu

    2018-03-01

    Non-detection of γ-ray emission from galaxy clusters has challenged diffusive shock acceleration (DSA) of cosmic-ray (CR) protons at weak collisionless shocks that are expected to form in the intracluster medium. As an effort to address this problem, we here explore possible roles of Alfvén waves self-excited via resonant streaming instability during the CR acceleration at parallel shocks. The mean drift of Alfvén waves may either increase or decrease the scattering center compression ratio, depending on the postshock cross-helicity, leading to either flatter or steeper CR spectra. We first examine such effects at planar shocks, based on the transport of Alfvén waves in the small amplitude limit. For the shock parameters relevant to cluster shocks, Alfvénic drift flattens the CR spectrum slightly, resulting in a small increase of the CR acceleration efficiency, η. We then consider two additional, physically motivated cases: (1) postshock waves are isotropized via MHD and plasma processes across the shock transition, and (2) postshock waves contain only forward waves propagating along with the flow due to a possible gradient of CR pressure behind the shock. In these cases, Alfvénic drift could reduce η by as much as a factor of five for weak cluster shocks. For the canonical parameters adopted here, we suggest η ∼ 10‑4–10‑2 for shocks with sonic Mach number M s ≈ 2–3. The possible reduction of η may help ease the tension between non-detection of γ-rays from galaxy clusters and DSA predictions.

  4. Integrating knowledge-based systems into operations at the McMaster University FN tandem accelerator laboratory

    International Nuclear Information System (INIS)

    Poehlman, W.F.S.; Stark, J.W.

    1989-01-01

    The introduction of computer-based expertise in accelerator operations has resulted in the development of an Accelerator Operators' Companion which incorporates a knowledge-based front-end that is tuned to user operational expertise. The front-end also provides connections to traditional software packages such as database and spreadsheet programs. During work on the back-end, that is, real-time expert system control development, the knowledge engineering phase has revealed the importance of modifying expert procedures when a multitasking environment is involved

  5. Choice of initial operating parameters for high average current linear accelerators

    International Nuclear Information System (INIS)

    Batchelor, K.

    1976-01-01

    Recent emphasis on alternative energy sources together with the need for intense neutron sources for testing of materials for CTR has resulted in renewed interest in high current (approximately 100 mA) c.w. proton and deuteron linear accelerators. In desinging an accelerator for such high currents, it is evident that beam losses in the machine must be minimized, which implies well matched beams, and that adequate acceptance under severe space charge conditions must be met. An investigation is presented of the input parameters to an Alvarez type drift-tube accelerator resulting from such factors. The analysis indicates that an accelerator operating at a frequency of 50 MHz is capable of accepting deuteron currents of about 0.4 amperes and proton currents of about 1.2 amperes. These values depend critically on the assumed values of beam emittance and on the ability to properly ''match'' this to the linac acceptance

  6. Assessment and treatment planning of lateral intracranial dural arteriovenous fistulas in 3 T MRI and DSA: A detailed analysis under consideration of time-resolved imaging of contrast kinetics (TRICKS) and ce-MRA sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ertl, L.; Brueckmann, H.; Patzig, M.; Brem, C.; Forbrig, R.; Fesl, G. [Ludwig-Maximilians-University, Grosshadern Campus, Department of Neuroradiology, Institute of Clinical Radiology, Munich (Germany); Kunz, M. [Ludwig-Maximilians-University, Grosshadern Campus, Department of Neurosurgery, Munich (Germany)

    2016-12-15

    The current gold standard in the assessment of lateral intracranial dural arteriovenous fistulas (LDAVF) is digital subtraction angiography (DSA). However, magnetic resonance imaging (MRI) is a non-invasive emerging tool for the evaluation of such lesions. The aim of our study was to compare the DSA to our 3 T MR-imaging protocol including a highly spatial resolved (ce-MRA) and a temporal resolved (''time-resolved imaging of contrast kinetics'', TRICKS) contrast-enhanced MR angiography to evaluate if solely DSA can remain the gold-standard imaging modality for the treatment planning of LDAVF. We retrospectively reviewed matched pairs of DSA and 3 T MRI examinations of 24 patients with LDAVF (03/2008-04/2014) by the same list of relevant criteria for an endovascular LDAVF treatment planning. In particular, we determined intermodality agreement for the Cognard classification, the identifeication of arterial feeders, and the detailed assessment of each venous drainage pattern. Intermodality agreement for the Cognard classification was excellent (k = 1.0). Whereas MRI failed in identifying small arterial feeders, it was superior to the DSA in the assessment of the sinus and the venous drainage pattern. The combination of MRI and DSA is the new gold standard in LDAVF treatment planning. (orig.)

  7. Electrochemical oxidation of bio-refractory dye in a simulated textile industry effluent using DSA electrodes in a filter-press type FM01-LC reactor.

    Science.gov (United States)

    Rodríguez, Francisca A; Mateo, María N; Aceves, Juan M; Rivero, Eligio P; González, Ignacio

    2013-01-01

    This work presents a study on degradation of indigo carmine dye in a filter-press type FM01-LC reactor using Sb2O5-doped Ti/IrO2-SnO2 dimensionally stable anode (DSA) electrodes. Micro- and macroelectrolysis studies were carried out using solutions of 0.8 mM indigo carmine in 0.05 M NaCl, which resemble blue denim laundry industrial wastewater. Microelectrolysis results show the behaviour of DSA electrodes in comparison with the behaviour of boron-doped diamond (BDD) electrodes. In general, dye degradation reactions are carried out indirectly through active chlorine generated on DSA, whereas in the case of BDD electrodes more oxidizing species are formed, mainly OH radicals, on the electrode surface. The well-characterized geometry, flow pattern and mass transport of the FM01-LC reactor used in macroelectrolysis experiments allowed the evaluation of the effect of hydrodynamic conditions on the chlorine-mediated degradation rate. Four values of Reynolds number (Re) (93, 371, 464 and 557) at four current densities (50, 100, 150 and 200 A/m2) were tested. The results show that the degradation rate is independent of Re at low current density (50 A/m2) but becomes dependent on the Re at high current density (200 A/m2). This behaviour shows the central role of mass transport and the reactor parameters and design. The low energy consumption (2.02 and 9.04 kWh/m3 for complete discolouration and chemical oxygen demand elimination at 50 A/m2, respectively) and the low cost of DSA electrodes compared to BDD make DSA electrodes promising for practical application in treating industrial textile effluents. In the present study, chlorinated organic compounds were not detected.

  8. Construction, commissioning and operational experience of the Advanced Photon Source (APS) linear accelerator

    International Nuclear Information System (INIS)

    White, M.; Arnold, N.; Berg, W.

    1996-01-01

    The Advanced Photon Source linear accelerator system consists of a 200 MeV, 2856 MHz S-Band electron linac and a 2-radiation-thick tungsten target followed by a 450 MeV positron linac. The linac system has operated 24 hours per day for the past year to support accelerator commissioning and beam studies and to provide beam for the user experimental program. It achieves the design goal for positron current of 8 mA and produces electron energies up to 650 MeV without the target in place. The linac is described and its operation and performance are discussed

  9. Construction, commissioning and operational experience of the Advanced Photon Source (APS) linear accelerator

    International Nuclear Information System (INIS)

    White, M.; Arnold, N.; Berg, W.; Cours, A.; Fuja, R.; Grelick, A. E.; Sereno, N.; Wesolowski, W.; Ko, K.; Qian, Y.L.; Russell, T.

    1996-01-01

    The Advanced Photon Source linear accelerator system consists of a 200-MeV, 2856-MHz S-band electron linac and a 2-radiation-thick tungsten target followed by a 450-MeV positron linac. The linac system has operated 24 hours per day for the past year to support accelerator commissioning and beam studies and to provide beam for the user experimental program. It achieves the design goal for positron current of 8 mA and produces electron energies up to 650 MeV without the target in place. The linac is described and its operation and performance are discussed. (author)

  10. Change in operating parameters of the Continuous Electron Beam Accelerator Facility and Free Electron Laser, Thomas Jefferson National Accelerator Facility, Newport News, Virginia

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-01

    In this environmental assessment (EA), the US Department of Energy (DOE) reports the results of an analysis of the potential environmental impacts from a proposed change in operating parameters of the Continuous Electron Beam Accelerator Facility (CEBAF), and operation of the Free Electron Laser (FEL) facility beyond the initial demonstration period. With this proposal, DOE intends to increase CEBAF operating range from its current operating maximum beam energy of 4.0 GeV [giga-(billion) electron volts] to 8.0 GeV at a beam power of no greater than 1,000 kW [1 megawatt (MW)], its maximum attainable level, based on current technology and knowledge, without significant, costly equipment modifications. DOE has prepared an EA for this action to determine the potential for adverse impacts from operation of CEBAF and the FEL at the proposed levels. Changing the operating parameters of CEBAF would require no new major construction and minor modifications to the accelerator, its support systems, the FEL, and onsite utility systems. Modifications and performance improvements would be made to (1) the accelerator housed in the underground tunnels, (2) its support systems located in the above ground service buildings, and (3) the water and equipment cooling systems both in the tunnel and at the ground surface. All work would be performed on previously disturbed land and in, on, or adjacent to existing buildings, structures, and equipment. With the proposed action, the recently constructed FEL facility at the Jefferson Lab would operate in concert with CEBAF beyond its demonstration period and up to its maximum effective electron beam power level of 210 kW. In this EA, DOE evaluates the impacts of the no-action alternative and the proposed action alternative. Alternatives considered, but dismissed from further evaluation, were the use of another accelerator facility and the use of another technology.

  11. Change in operating parameters of the Continuous Electron Beam Accelerator Facility and Free Electron Laser, Thomas Jefferson National Accelerator Facility, Newport News, Virginia

    International Nuclear Information System (INIS)

    1997-10-01

    In this environmental assessment (EA), the US Department of Energy (DOE) reports the results of an analysis of the potential environmental impacts from a proposed change in operating parameters of the Continuous Electron Beam Accelerator Facility (CEBAF), and operation of the Free Electron Laser (FEL) facility beyond the initial demonstration period. With this proposal, DOE intends to increase CEBAF operating range from its current operating maximum beam energy of 4.0 GeV [giga-(billion) electron volts] to 8.0 GeV at a beam power of no greater than 1,000 kW [1 megawatt (MW)], its maximum attainable level, based on current technology and knowledge, without significant, costly equipment modifications. DOE has prepared an EA for this action to determine the potential for adverse impacts from operation of CEBAF and the FEL at the proposed levels. Changing the operating parameters of CEBAF would require no new major construction and minor modifications to the accelerator, its support systems, the FEL, and onsite utility systems. Modifications and performance improvements would be made to (1) the accelerator housed in the underground tunnels, (2) its support systems located in the above ground service buildings, and (3) the water and equipment cooling systems both in the tunnel and at the ground surface. All work would be performed on previously disturbed land and in, on, or adjacent to existing buildings, structures, and equipment. With the proposed action, the recently constructed FEL facility at the Jefferson Lab would operate in concert with CEBAF beyond its demonstration period and up to its maximum effective electron beam power level of 210 kW. In this EA, DOE evaluates the impacts of the no-action alternative and the proposed action alternative. Alternatives considered, but dismissed from further evaluation, were the use of another accelerator facility and the use of another technology

  12. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2007. Operation, utilization and technical development of JRR-3, JRR-4, NSRR and tandem accelerator

    International Nuclear Information System (INIS)

    Miyazaki, Osamu; Awa, Yasuaki; Isaka, Koji; Kutsukake, Kenichi; Komeda, Masao; Shibata, Ko; Hiyama, Kazuhisa; Suzuki, Mayu; Sone, Takuya; Ohuchi, Tomoaki; Terakado, Yuichi; Sataka, Masao

    2009-06-01

    The Department of Research Reactors and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3(Japan Research Reactor-3), JRR-4(Japan Research Reactor-4), NSRR(Nuclear Safety Research Reactor) and Tandem Accelerator. This annual report describes a summary of activities of services and technical developments carried out in the period between April 1, 2007 and March 31, 2008. The activities were categorized into five service/development fields: (1) Operation and maintenance of research reactors and tandem accelerator. (2) Utilization of research reactors and tandem accelerator. (3) Upgrading of utilization techniques of research reactors and tandem accelerator. (4) Safety administration for research reactors and tandem accelerator. (5) International cooperation. Also contained are lists of publications, meetings, granted permissions on lows and regulations concerning atomic energy, commendation, plans and outcomes in service and technical developments and so on. (author)

  13. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2010. Operation, utilization and technical development of JRR-3, JRR-4, NSRR and Tandem Accelerator

    International Nuclear Information System (INIS)

    Ishii, Tetsuro; Nakamura, Kiyoshi; Kawamata, Satoshi; Yamada, Yusuke; Kawashima, Kazuhiro; Asozu, Takuhiro; Nakamura, Takemi; Arai, Masaji; Yoshinari, Shuji; Sataka, Masao

    2012-03-01

    The Department of Research Reactors and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3(Japan Research Reactor No.3), JRR-4(Japan Research Reactor No.4), NSRR(Nuclear Safety Research Reactor) and Tandem Accelerator. This annual report describes a summary of activities of services and technical developments carried out in the period between April 1, 2010 and March 31, 2011. The activities were categorized into five service/development fields: (1) Operation and maintenance of research reactors and tandem accelerator, (2) Utilization of research reactors and tandem accelerator, (3) Upgrading of utilization techniques of research reactors and tandem accelerator, (4) Safety administration for research reactors and tandem accelerator, (5) International cooperation. Also contained are lists of publications, meetings, granted permissions on lows and regulations concerning atomic energy, commendation, outcomes in service and technical developments and so on. (author)

  14. Automated tracking of the vascular tree on DSA images

    International Nuclear Information System (INIS)

    Alperin, N.; Hoffmann, K.R.; Doi, K.

    1990-01-01

    Determination of the vascular tree structure is important for reconstruction of three-dimensional vascular tree from biplane images, for assessment of the significance of a lesion, and for planning treatment for arteriovenous malformation. To automate these analyses, the authors of this paper are developing a method to determine the vascular tree structure from digital subtraction angiography (DSA) images. The authors have previously described a vessel tracking method, based on the double-square-box technique. To improve the tracking accuracy, they have developed and integrated with the previous method a connectivity test and guided-sector-search technique. The connectivity test, based on region growing techniques, eliminates tracking across nonvessel regions. The guided sector-search method incorporates information from a larger are of the image to guide the search for the next tracking point

  15. How accelerator operations does business at Jefferson Lab

    International Nuclear Information System (INIS)

    Green, David W. Jr.

    2004-01-01

    The accelerator is staffed 24 hours a day by the MCC Operations Group. Shift rotations are for seven days on shift, followed by seven days off shift, of which three days are spent on off-shift activities. Personnel spend 70% of their time on shift and 30% off shift. The off-shift time is utilized for meetings, training and individual projects. Individual projects can consist of hardware or software development, training, documentation development or other areas of interest, depending on the individual. (author)

  16. Evaluation of the carotid and vertebral arteries: comparison of 3D SCTA and IA-DSA-work in progress

    International Nuclear Information System (INIS)

    Seemann, M.D.; Minx, C.; Heuck, A.; Reiser, M.F.; Englmeier, K.H.; Schuhmann, D.R.G.; Fuerst, H.

    1999-01-01

    Objective: The purpose of this study was to develop a method for three-dimensional (3D) visualization of the whole vascular system of the carotid and vertebral arteries using spiral computed tomographic angiography (SCTA), that allows accurate, qualitative and quantitative evaluation, of anatomical abnormalities, including detection of additional lesions, and estimation of degree of stenosis. Materials and methods: Fifteen patients with anatomical and pathological abnormalities of the arterial vascular system detected by color-coded duplex ultrasound were studied using intraarterial digital subtraction angiography (IA-DSA) with aortic arch injection, and SCTA. The carotid and vertebral arteries were segmented using an interactive threshold interval density volume-growing method and visualized with a color-coded shaded-surface display (SSD) rendering method. The adjacent bone structures were visualized using a transparent volume rendering method. Results: In all cases, the entire volume of the vascular system of the carotid and vertebral arteries could be visualized on SCTA, and the anatomical and pathological abnormalities on 3D SCTA correlated well with that seen on IA-DSA. Conclusion: Results of 3D SCTA had a high degree of correlation with results of IA-DSA in the evaluation of the vascular system of the carotid and vertebral arteries. The 3D SCTA with a subsecond spiral CT scanner is useful for the visualization of anatomical and pathological abnormalities in the circulation in the carotid and vertebral arteries and offer a promising minimally invasive alternative compared with other diagnostic procedures. (orig.) (orig.)

  17. GANIL, Technical report on operating accelerators, 1995-1996

    International Nuclear Information System (INIS)

    Bex, M.

    1998-01-01

    This report covers the years 1995-1996 and presents the GANIL accelerator operation, the machine studies, the technical developments, the safety problems, the SISSI system and the THI project. The technical developments refer to: production of multicharged metallic ions by the association of an excimer laser and an ECR source; production of multicharged metallic ions with an ECR source by the sputtering method; detection of beam losses and safety system for these losses; rotating spiraled wire; renovation or RF systems; renovation of power supplies and NMR system; upgrade of GANIL control system cluster; adaptation of the GANIL control system to the SPIRAL project and control system for NMR probe measurements. Annexes giving the experiments performed in nuclear physics and in fast ion physics are given as well as a list of the beams accelerated together with their characteristics (charged state, frequency, final energy, intensity on target). Also added is a list of publications

  18. Control system user interface for accelerator commissioning and operation

    International Nuclear Information System (INIS)

    Dobrott, D.; Keeley, D.; Kolte, G.; Mikic, Z.; Lee, M.; Corbett, J.; Howry, S.; King, A.

    1991-01-01

    An Interactive Accelerator Interface Module (AIM) has been developed in a workstation environment for the purposes of assisting in the commissioning and operation of any storage ring/collider system. The function of AIM is to integrate modeling and simulation codes into accelerator and beamline control systems for the purpose of rapid on-line data analysis and error-correction, resulting in significant time-saving. A system dependent module provides for the translation of specific control system data files to appropriate input format for application programs within AIM. Interactive screen graphics, including system function diagrams, menus, beamline element status and update information are standard in AIM. AIM is currently connected to the Stanford Linear Collider (SLC) control system, but is easily transportable to other facilities. This paper describes the development of AIM and its applications on SLC

  19. Rapid application development by KEKB accelerator operators using EPICS/Python

    International Nuclear Information System (INIS)

    Tanaka, M.; Satoh, Y.; Kitabayashi, T.

    2004-01-01

    In the KEKB accelerator facility, the control system is constructed based on the framework of EPICS. By using EPICS/Python API, which is originated from KEK, we can develop an EPICS channel access application based on simple Python technology with only a few knowledge of EPICS channel access protocols. The operator's new tuning ideas are quickly implemented to the control system. In this paper, we introduce the EPICS/Python API and report the effectiveness of rapid application development by the KEKB operators using the API. (author)

  20. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2011. Operation, utilization and technical development of JRR-3, JRR-4, NSRR and tandem accelerator

    International Nuclear Information System (INIS)

    Ishii, Tetsuro; Nakamura, Kiyoshi; Kawamata, Satoshi; Ishikuro, Yasuhiro; Kawashima, Kazuhito; Kabumoto, Hiroshi; Nakamura, Takemi; Tamura, Itaru; Kawasaki, Sayuri; Sataka, Masao

    2013-03-01

    The Department of Research Reactors and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3(Japan Research Reactor No.3), JRR-4(Japan Research Reactor No.4), NSRR(Nuclear Safety Research Reactor) and Tandem Accelerator. This annual report describes a summary of activities of services and technical developments carried out in the period between April 1, 2011 and March 31, 2012. The activities were categorized into six service/development fields: (1) Recovery from the Great East Japan Earthquake, (2) Operation and maintenance of research reactors and tandem accelerator, (3) Utilization of research reactors and tandem accelerator, (4) Upgrading of utilization techniques of research reactors and tandem accelerator, (5) Safety administration for research reactors and tandem accelerator, (6) International cooperation. Also contained are lists of publications, meetings, granted permissions on lows and regulations concerning atomic energy, number of staff members dispatched to Fukushima for the technical assistance, commendation, outcomes in service and technical developments and so on. (author)

  1. Concepts and techniques: Active electronics and computers in safety-critical accelerator operation

    International Nuclear Information System (INIS)

    Frankel, R.S.

    1995-01-01

    The Relativistic Heavy Ion Collider (RHIC) under construction at Brookhaven National Laboratory, requires an extensive Access Control System to protect personnel from Radiation, Oxygen Deficiency and Electrical hazards. In addition, the complicated nature of operation of the Collider as part of a complex of other Accelerators necessitates the use of active electronic measurement circuitry to ensure compliance with established Operational Safety Limits. Solutions were devised which permit the use of modern computer and interconnections technology for Safety-Critical applications, while preserving and enhancing, tried and proven protection methods. In addition a set of Guidelines, regarding required performance for Accelerator Safety Systems and a Handbook of design criteria and rules were developed to assist future system designers and to provide a framework for internal review and regulation

  2. Concepts and techniques: Active electronics and computers in safety-critical accelerator operation

    Energy Technology Data Exchange (ETDEWEB)

    Frankel, R.S.

    1995-12-31

    The Relativistic Heavy Ion Collider (RHIC) under construction at Brookhaven National Laboratory, requires an extensive Access Control System to protect personnel from Radiation, Oxygen Deficiency and Electrical hazards. In addition, the complicated nature of operation of the Collider as part of a complex of other Accelerators necessitates the use of active electronic measurement circuitry to ensure compliance with established Operational Safety Limits. Solutions were devised which permit the use of modern computer and interconnections technology for Safety-Critical applications, while preserving and enhancing, tried and proven protection methods. In addition a set of Guidelines, regarding required performance for Accelerator Safety Systems and a Handbook of design criteria and rules were developed to assist future system designers and to provide a framework for internal review and regulation.

  3. Clinical effectiveness of DSA-guided foam sclerotherapy for varicose veins of lower limbs

    International Nuclear Information System (INIS)

    Fu Jianhua; He Xu; Chen Guoping; Gu Jianping; Wang Yafei

    2011-01-01

    Objective: To investigate the clinical effect of DSA-guided foam sclerotherapy for varicose veins of lower limbs. Methods: A total of 25 diseased limbs in 20 patients with varicose veins were treated with foam sclerotherapy. The patients were followed up for six months. Sodium morrhuate, used as the sclerosant, was foamed with air by using Tessari's method, with liquid-gas ratio of 1 : 4. The clinical effectiveness was estimated by CEAP, clinical signs and symptoms. Results: A total of 25 limbs in 20 patients with varicose veins were successfully treated with foam sclerotherapy. The technical success rate was 100%. No serious complications such as pulmonary embolism occurred. Phlebitis was observed in two cases at 2 days 4 days after foam sclerotherapy respectively which was relieved after anti-inflammatory medication for 3 days. At the time of discharge, excellent result was seen in 12 (48%) limbs, good effect in 13 (52%) limbs. The total effective rate was 100%. Six months after the treatment, excellent effect was obtained in 15 (60%) limbs and good effect was seen in 10 (40%) limbs. The total effective rate was 100%. Conclusion: DSA-guided foam sclerotherapy is a safe, effective and micro-invasive treatment for varicose veins of lower limbs with high technical success rate, although the long-term clinical effect needs to be further evaluated. (authors)

  4. Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA

    International Nuclear Information System (INIS)

    Ramgren, Birgitta; Siemund, Roger; Cronqvist, Mats; Undren, Per; Holtaas, Stig; Nilsson, Ola G.; Larsson, Elna-Marie

    2008-01-01

    The purpose of this prospective study was to compare 3T and 1.5T magnetic resonance angiography (MRA) with digital subtraction angiography (DSA) for the follow-up of endovascular treated intracranial aneurysms to assess the grade of occlusion. Thirty-seven patients with 41 aneurysms who had undergone endovascular treatment with detachable coils were included. MRA was performed on the same day using an eight-channel sensitivity encoding head-coil with 3D axial inflow technique. At 3T, a contrast-enhanced transverse 3D fast gradient echo acquisition was also performed. Most patients underwent DSA the following day. MRA scans and DSA were classified first independently by two neuroradiologists and an interventional neuroradiologist. Secondly, a consensus was done. Source images, maximum intensity projection, multiplanar reconstruction and volume rendering reconstructions were used for MRA evaluations. A modification of the Raymond classification, previously used for DSA evaluation of recanalization, was used. Statistical comparison of the consensus showed that 3T MRA with 3D axial inflow technique had better agreement with DSA (κ = 0.43) than 1.5T MRA(κ = 0.21) and contrast-enhanced MRA (CE-MRA) at 3T (κ = 0.17). The susceptibility artefacts from the coil mesh were significally smaller at 3T (p = 0.002-0.007) than at 1.5T. 3T MRA, using a sensitivity encoding head-coil, showed better agreement with DSA than 1.5T and CE-MRA at 3T for evaluation of aneurysms treated with endovascular coiling. (orig.)

  5. Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

    Science.gov (United States)

    Xiao, Zebin; Zheng, Yingyan; Li, Jian; Chen, Dehua; Liu, Fang; Cao, Dairong

    2017-12-01

    To explore the value of four-dimensional CT angiography (4D-CTA) in the preoperative evaluation of juvenile nasopharyngeal angiofibromas (JNAs) using 320-row volume CT. 4D-CTA and DSA data of 18 patients with histopathologically proven JNAs were retrospectively reviewed. The location, extent, feeding vessels and stage of JNAs were assessed by two radiologists independently and blindly. The agreements between both reviewers and between 4D-CTA and surgical findings for assessing the above indicators were analysed, respectively. The radiation dose and the number of feeding arteries between 4D-CTA and digital subtraction angiography (DSA) were also compared. 4D-CTA showed high diagnostic consistency with surgical pathology for JNAs with consistent rates of 96.2 and 100% in both reviewers, respectively. The effective dose of 4D-CTA was significantly less than that of DSA (p 0.05). 4D-CTA can provide a reliable preoperative diagnosis and assessment of JNAs, which is useful for determining the surgical strategy and management of this condition.

  6. TU-H-BRA-06: Characterization of a Linear Accelerator Operating in a Compact MRIGuided Radiation Therapy System

    International Nuclear Information System (INIS)

    Green, O; Mutic, S; Li, H; Low, D; Chmielewski, T; Fought, G; Hernandez, M; Kawrakow, I; Sharma, A; Shvartsman, S; Dempsey, J

    2016-01-01

    Purpose: To describe the performance of a linear accelerator operating in a compact MRI-guided radiation therapy system. Methods: A commercial linear accelerator was placed in an MRI unit that is employed in a commercial MR-based image guided radiation therapy (IGRT) system. The linear accelerator components were placed within magnetic field-reducing hardware that provided magnetic fields of less than 40 G for the magnetron, gun driver, and port circulator, with 1 G for the linear accelerator. The system did not employ a flattening filter. The test linear accelerator was an industrial 4 MV model that was employed to test the ability to run an accelerator in the MR environment. An MR-compatible diode detector array was used to measure the beam profiles with the accelerator outside and inside the MR field and with the gradient coils on and off to examine if there was any effect on the delivered dose distribution. The beam profiles and time characteristics of the beam were measured. Results: The beam profiles exhibited characteristic unflattened Bremsstrahlung features with less than ±1.5% differences in the profile magnitude when the system was outside and inside the magnet and less than 1% differences with the gradient coils on and off. The central axis dose rate fluctuated by less than 1% over a 30 second period when outside and inside the MRI. Conclusion: A linaccompatible MR design has been shown to be effective in not perturbing the operation of a commercial linear accelerator. While the accelerator used in the tests was 4MV, there is nothing fundamentally different with the operation of a 6MV unit, implying that the design will enable operation of the proposed clinical unit. Research funding provided by ViewRay, Inc.

  7. TU-H-BRA-06: Characterization of a Linear Accelerator Operating in a Compact MRIGuided Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Green, O; Mutic, S; Li, H [Washington University School of Medicine, St. Louis, MO (United States); Low, D [University of California, Los Angeles, CA (United States); Chmielewski, T; Fought, G; Hernandez, M; Kawrakow, I; Sharma, A; Shvartsman, S; Dempsey, J [ViewRay, Inc., Oakwood Village, OH (United States)

    2016-06-15

    Purpose: To describe the performance of a linear accelerator operating in a compact MRI-guided radiation therapy system. Methods: A commercial linear accelerator was placed in an MRI unit that is employed in a commercial MR-based image guided radiation therapy (IGRT) system. The linear accelerator components were placed within magnetic field-reducing hardware that provided magnetic fields of less than 40 G for the magnetron, gun driver, and port circulator, with 1 G for the linear accelerator. The system did not employ a flattening filter. The test linear accelerator was an industrial 4 MV model that was employed to test the ability to run an accelerator in the MR environment. An MR-compatible diode detector array was used to measure the beam profiles with the accelerator outside and inside the MR field and with the gradient coils on and off to examine if there was any effect on the delivered dose distribution. The beam profiles and time characteristics of the beam were measured. Results: The beam profiles exhibited characteristic unflattened Bremsstrahlung features with less than ±1.5% differences in the profile magnitude when the system was outside and inside the magnet and less than 1% differences with the gradient coils on and off. The central axis dose rate fluctuated by less than 1% over a 30 second period when outside and inside the MRI. Conclusion: A linaccompatible MR design has been shown to be effective in not perturbing the operation of a commercial linear accelerator. While the accelerator used in the tests was 4MV, there is nothing fundamentally different with the operation of a 6MV unit, implying that the design will enable operation of the proposed clinical unit. Research funding provided by ViewRay, Inc.

  8. DSA lifetime measurements in 21Ne at high recoil velocity

    International Nuclear Information System (INIS)

    Grawe, H.; Heidinger, F.; Kaendler, K.

    1977-01-01

    States in 21 Ne up to 5 MeV excitation energy have been populated using the inverted reaction 2 H( 20 Ne,pγ). The Doppler shift attenuation (DSA) analysis of the pγ coincidence spectra taken in a Ge(Li) detector at 45 0 and 135 0 and an annular silicon surface barrier detector near 0 0 yielded the lifetimes of 8 states in 21 Ne. Due to the large recoil of vi/c approximately equal to 4% three new lifetimes were determined for the short lived levels at 2.80, 4.68 and 4.73 MeV, namely 10 +- 4 fs, 16 +- 4 fs and 10 +- 4 fs, respectively. The results are compared with rotational and shell model calculations. (orig.) [de

  9. The investigation of the design of hybrid operating room

    International Nuclear Information System (INIS)

    Jiang Weihao; Li Jun

    2011-01-01

    Objective: To investigate the design of the interventional operating room that can meet the needs of modern DSA operation, and the overall arrangement of the hybrid operating room should be reasonable, practical and perspective. Methods: The experience and understanding obtained from the designing and planning of the new Building of Radiology and Surgery in authors' hospital were summarized. In order to meet the requirements of aseptic surgical practices and a full-featured hybrid operating room the following factors should be carefully and synthetically taken into account: the room size, the functional sub-areas, the operational procedures, the aseptic specification, etc. Results: The sufficient verification and scientific design were the important link for building a hybrid operating room. It could provide the surgeons and interventional physicians with more alternative operating methods and it could represent the development trend of medical technology. Conclusion: When planning and designing a new DSA operating room, various factors related to the interventional procedures, such as the room size, the functional sub-areas, the operational procedures and the aseptic specification, should be carefully and synthetically taken into account. The standard of aseptic procedure must be strictly complied with and the various functional sub-areas need to be rationally distributed. The design of hybrid operating room, which joins the functions of both open surgery and interventional management together, should be scientific, practical and perspective. (authors)

  10. Determination of acceleration for belt conveyor speed control in transient operation

    NARCIS (Netherlands)

    He, D.; Pang, Y.; Lodewijks, G.

    2016-01-01

    Speed control has been found a feasible mean to reduce the energy consumption of belt conveyors. However, the current research has not taken the determination of the acceleration in transient operation into account sufficiently. With respect to the belt tension rating, demanded safety factor and the

  11. Accelerator Service

    International Nuclear Information System (INIS)

    Champelovier, Y.; Ferrari, M.; Gardon, A.; Hadinger, G.; Martin, J.; Plantier, A.

    1998-01-01

    Since the cessation of the operation of hydrogen cluster accelerator in July 1996, four electrostatic accelerators were in operation and used by the peri-nuclear teams working in multidisciplinary collaborations. These are the 4 MV Van de Graaff accelerator, 2,5 MV Van de Graaff accelerator, 400 kV ion implanter as well as the 120 kV isotope separator

  12. Conception, construction, and taking into operation of a pre-accelerator system at ELSA

    International Nuclear Information System (INIS)

    Klarner, Fabian

    2011-01-01

    In order to enhance the operating capabilities of the Bonn University Accelerator Facility ELSA by a single pulse mode, a new injector was designed, built up and successfully commissioned. In addition, the new injector was designed to provide an unpolarized electron beam with increased current to the external hadron physics experiments. For this purpose, the injector will produce an 1-3 microseconds long pulse of 900 mA beam current or a single electron bunch with 1.5 A pulse current. For single bunch operation, a 1.5 ns long pulse is produced by a thermal electron source, then compressed and pre-accelerated by a subsequent resonator and a four-cell travelling wave buncher. After acceleration of the electrons in the main linac, the natural broadening of the energy distribution in the particle ensemble due to the acceleration process will be reduced by an energy compressor system. By the succeeding optical elements in the transfer beamline, the beam is guided to the synchrotron, taking into account the requirements for injection into the synchrotron including its acceptance. Finally, the first beam of the new LINAC1 section was successfully used to irradiate ammonia for preparation as polarized target material for the COMPASS experiment and to irradiate detector components of the DEPFET project. (orig.)

  13. New technologies for acceleration and vibration measurements inside operating nuclear power reactors

    International Nuclear Information System (INIS)

    Runkel, J.; Stegemann, D.; Fiedler, J.; Heidemann, P.; Blaser, R.; Schmid, F.; Trobitz, M.; Hirsch, L.; Thoma, K.

    2000-01-01

    A miniature bi-axial in-core accelerometer has been inserted temporarily inside the travelling in-core probe (TIP) systems of operating 1300 MW el boiling water reactors (BWR) during full power operation. In-core acceleration measurements can be performed in any position of the TIP system. This provides new features of control technologies to preserve the integrity of reactor internals. The radial and axial position where fretting or impacting of instrumentation string tubes or other structures might occur can be localised inside the reactor pressure vessel. The efficiency and long-term performance of subsequent improvements of the mechanical or operating conditions can be controlled with high local resolution and sensitivity. Low frequency vibrations of the instrumentation tubes were measured inside the core. Neutron-mechanical scale factors were determined from neutron noise, measured by the standard in-core neutron instrumentation and from displacements of the TIP tubes, calculated by integration of the measured in-core acceleration signals. The scale factors contribute to qualitative and quantitative monitoring of BWR internals' vibrations only by the use of neutron signals. (authors)

  14. Optimal space-energy splitting in MCNP with the DSA

    International Nuclear Information System (INIS)

    Dubi, A.; Gurvitz, N.

    1990-01-01

    The Direct Statistical Approach (DSA) particle transport theory is based on the possibility of obtaining exact explicit expressions for the dependence of the second moment and calculation time on the splitting parameters. This allows the automatic optimization of the splitting parameters by ''learning'' the bulk parameters from which the problem dependent coefficients of the quality function (second moment time) are constructed. The above procedure was exploited to implement an automatic optimization of the splitting parameters in the Monte Carlo Neutron Photon (MCNP) code. This was done in a number of steps. In the first instance, only spatial surface splitting was considered. In this step, the major obstacle has been the truncation of an infinite series of ''products'' of ''surface path's'' leading from the source to the detector. Encouraging results from the first phase led to the inclusion of full space/energy phase space splitting. (author)

  15. How to Commission, Operate and Maintain a Large Future Accelerator Complex From Far Remote Sites

    International Nuclear Information System (INIS)

    Phinney, Nan

    2001-01-01

    A study on future large accelerators [1] has considered a facility, which is designed, built and operated by a worldwide collaboration of equal partner institutions, and which is remote from most of these institutions. The full range of operation was considered including commissioning, machine development, maintenance, trouble shooting and repair. Experience from existing accelerators confirms that most of these activities are already performed remotely. The large high-energy physics experiments and astronomy projects, already involve international collaborations of distant institutions. Based on this experience, the prospects for a machine operated remotely from far sites are encouraging. Experts from each laboratory would remain at their home institution but continue to participate in the operation of the machine after construction. Experts are required to be on site only during initial commissioning and for particularly difficult problems. Repairs require an on-site non-expert maintenance crew. Most of the interventions can be made without an expert and many of the rest resolved with remote assistance. There appears to be no technical obstacle to controlling an accelerator from a distance. The major challenge is to solve the complex management and communication problems

  16. How to Commission, Operate and Maintain a Large Future Accelerator Complex From Far Remote Sites

    Energy Technology Data Exchange (ETDEWEB)

    Phinney, Nan

    2001-12-07

    A study on future large accelerators [1] has considered a facility, which is designed, built and operated by a worldwide collaboration of equal partner institutions, and which is remote from most of these institutions. The full range of operation was considered including commissioning, machine development, maintenance, troubleshooting and repair. Experience from existing accelerators confirms that most of these activities are already performed 'remotely'. The large high-energy physics experiments and astronomy projects, already involve international collaborations of distant institutions. Based on this experience, the prospects for a machine operated remotely from far sites are encouraging. Experts from each laboratory would remain at their home institution but continue to participate in the operation of the machine after construction. Experts are required to be on site only during initial commissioning and for particularly difficult problems. Repairs require an on-site non-expert maintenance crew. Most of the interventions can be made without an expert and many of the rest resolved with remote assistance. There appears to be no technical obstacle to controlling an accelerator from a distance. The major challenge is to solve the complex management and communication problems.

  17. Operations and maintenance manual for the linear accelerator (sled)

    Science.gov (United States)

    1981-01-01

    The Linear Accelerator, a sliding chair which is pulled along a stationary platform in a horizontal axis is described. The driving force is a motor controlled by a velocity loop amplifier, and the mechanical link to the chair is a steel cable. The chair is moved in forward and reverse directions as indicated by the direction of motor rotation. The system operation is described with emphasis on the electronic control and monitoring functions. Line-by-line schematics and wire lists are included.

  18. Development of an automated system for the operation of an electron beam accelerator

    International Nuclear Information System (INIS)

    Somessari, Samir L.; Moura, João A.; Calvo, Wilson Ap. Parejo

    2017-01-01

    Electron beam accelerators are used in many applications, such as basic physical research, chemistry, medicine, molecular biology, microelectronics, agriculture and industry, among others. The majority of the accelerators have electrons from a hot tungsten filament and their energy is increased as it passes through an electric field in the vacuum chamber. For industrial purposes, the most common model is Dynamitrons®. At IPEN-CNEN/SP, there is an electron beam accelerator Dynamitron® Type (Manufactured by RDI- Radiation Dynamics Inc., 1978) model DC1500/25/4. The technology applied was available in the 60's and 70's, but, nowadays is obsolete. Moreover, there are not original spare parts for this equipment any longer. The aim of this work is to develop a nationalized automated operation system for the accelerator, to replace the old equipment. (author)

  19. Development of an automated system for the operation of an electron beam accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir L.; Moura, João A.; Calvo, Wilson Ap. Parejo, E-mail: somessar@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Electron beam accelerators are used in many applications, such as basic physical research, chemistry, medicine, molecular biology, microelectronics, agriculture and industry, among others. The majority of the accelerators have electrons from a hot tungsten filament and their energy is increased as it passes through an electric field in the vacuum chamber. For industrial purposes, the most common model is Dynamitrons®. At IPEN-CNEN/SP, there is an electron beam accelerator Dynamitron® Type (Manufactured by RDI- Radiation Dynamics Inc., 1978) model DC1500/25/4. The technology applied was available in the 60's and 70's, but, nowadays is obsolete. Moreover, there are not original spare parts for this equipment any longer. The aim of this work is to develop a nationalized automated operation system for the accelerator, to replace the old equipment. (author)

  20. The value of MR angiography in the diagnosis of deep vein thrombosis of the lower limbs: comparative study with DSA

    International Nuclear Information System (INIS)

    Feng Min; Wang Shuzhi; Gu Jianping; Sun Jun; Mao Cunnan; Lu Lingquan; Yin Xindao

    2007-01-01

    Objective: To assess the clinical values of MR angiography (MRA) in the detection of deep vein thrombosis of the lower limbs. Methods: Two-dimensional time of flight (2D TOF) MRA was performed in thirty patients who were suspected of having deep vein thrombosis in the lower limbs. The findings of MRA were compared to that of digital subtraction angiography (DSA). Results: twenty-five cases showed deep vein thrombosis in the lower limbs, the MRA findings included venous filling defect (14 cases), occlusions and interruptions of veins (8 cases), venous recanalizations (3 cases), collateral veins (25 cases). Taking the results of DSA as a golden standard, MRA detected all of the affected cases with only one case as the false positive. Conclusion: 2D TOF MRA is a method of choice in the diagnosis of deep vein thrombosis of the lower limbs. (authors)

  1. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  2. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  3. Intravenous DSA as a screening method for cerebral aneurysms

    International Nuclear Information System (INIS)

    Fukaya, Hiroyuki; Sunami, Kaneo; Hoshi, Seiichiro; Komiya, Hirokazu; Saeki, Naokatsu.

    1990-01-01

    Intravenous DSA (IVDSA) was evaluated as a screening method for cerebral aneurysms. It was performed 390 times in 372 cases. Clinically useful images were obtained in 94.1% in all examinations. Nineteen aneurysms were visualized in cerebral angiography among 21 cases with SAH or 3rd nerve palsy, whereas in IVDSA 15 aneurysms were noted. Aneurysms not visualized in IVDSA were all 4 mm or less in size. Therefore, aneurysms, more than 4 mm in size, which have higher risks for rupture, were detectable in IVDSA. Based on these findings, IVDSA is considered to be clinically useful in screening for aneurysms. In all 372 cases, 33 aneurysms were suspected in IVDSA findings, whereas in cerebral angiography 21 of them turned to be aneurysms. Such 12 false positive cases were distributed mainly at anterior communicating and middle cerebral arteries. Improvement of image resolution, avoidance of vessel overlapping and proper selection of screened cases should be investigated for further development of this screening method. (author)

  4. American National Standards Institute ANSI N 43.1 Radiological Safety in the Design and Operation of Particle Accelerators

    International Nuclear Information System (INIS)

    Scott Walker, L.; Liu, J.

    2004-01-01

    The ANSI N43 committee established a writing committee to re-write the ANSI N43.1 accelerator safety standard in 1994. James Liu and Scott Walker were appointed as co-chairman. Compared to the old standard, the new standard is aimed to have a broader application, up-to-date requirements, and recommendations for best practices. The new standard uses a hazard based graded approach to address radiation safety programs for accelerators with various energies, beam currents and applications (excluding medical accelerators which are covered by another standard). Thus, the standard fulfills the goal of the committee to prepare a standard with unlimited application to industrial and research accelerators. The standard is largely complete with chapters as follows: 1) Scope. 2) Definitions. 3) Radiation Safety Program (facility safety program, radiation safety planning, organizational considerations, safety assessment, review and performance evaluation). 4) Radiation Safety System (prompt radiation, safety system features, reliability and fail-safety, tamper resistance, quality control, configuration control, adventitious production of radiation, and induced radioactivity). 5) Personnel Access Control System (including graded approach, postings, barriers, beam inhibiting devices and interlocks). 6) Radiation Control System, (passive shielding, and active systems). 7) Accelerator Operation (including readiness reviews, maintenance and testing, bypasses and deviation from procedure, operating practices, emergencies). 8) Operational Health Physics, and 9) Training. The document also has appendices regarding how to determine the Safety and Operations Envelope, Guidance for Computer Based Access Control Systems, and Radiation Measurements at Accelerators. (Author)

  5. DARMSTADT: Superconducting electron accelerator in operation

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    In December, the S-DALINAC superconducting radiofrequency electron accelerator at the Nuclear Physics Institute of Darmstadt's Technische Hochschule was completed. This pioneer continuous-wave (c.w.) machine passed a major milestone several years ago when it accelerated its first low energy electron beam

  6. Shock Acceleration of Electrons and Synchrotron Emission from the Dynamical Ejecta of Neutron Star Mergers

    Science.gov (United States)

    Lee, Shiu-Hang; Maeda, Keiichi; Kawanaka, Norita

    2018-05-01

    Neutron star mergers (NSMs) eject energetic subrelativistic dynamical ejecta into circumbinary media. Analogous to supernovae and supernova remnants, the NSM dynamical ejecta are expected to produce nonthermal emission by electrons accelerated at a shock wave. In this paper, we present the expected radio and X-ray signals by this mechanism, taking into account nonlinear diffusive shock acceleration (DSA) and magnetic field amplification. We suggest that the NSM is unique as a DSA site, where the seed relativistic electrons are abundantly provided by the decays of r-process elements. The signal is predicted to peak at a few 100–1000 days after the merger, determined by the balance between the decrease of the number of seed electrons and the increase of the dissipated kinetic energy, due to the shock expansion. While the resulting flux can ideally reach the maximum flux expected from near-equipartition, the available kinetic energy dissipation rate of the NSM ejecta limits the detectability of such a signal. It is likely that the radio and X-ray emission are overwhelmed by other mechanisms (e.g., an off-axis jet) for an observer placed in a jet direction (i.e., for GW170817). However, for an off-axis observer, to be discovered once a number of NSMs are identified, the dynamical ejecta component is predicted to dominate the nonthermal emission. While the detection of this signal is challenging even with near-future facilities, this potentially provides a robust probe of the creation of r-process elements in NSMs.

  7. Van-de-Graaf accelerator operation with laser source of highly-charged heavy ions

    International Nuclear Information System (INIS)

    Barabash, L.S.; Golubev, A.A.; Koshkarev, S.G.; Krechet, K.I.; Sharkov, B.Y.; Shumshurov, A.V.

    1988-01-01

    Multicharged ions (Z = +1 divided-by +10) of practically any elements of the periodical table have been generated by the laser source based on a simple in operation and fabrication laser. One of the features of the laser source is that the energy needed for plasma heating is transported to the target from a great distance. In this case the target can be placed under high voltage or in a magnetic field. These advantages of the laser source are particularly important for its application in the Van-de-Graaf accelerator, where absence of resonance units allows to accelerate ions with any charge-to-mass ratio. The goal of this paper consists in designing a laser source of highly- charged heavy ions in the Van-de-Graaf accelerator and in measuring charge spectra of the accelerated ion beam. The peculiarities of this accelerator are taken into account in the discussion of the source scheme. Such peculiarities include potential up to 5 MV on the high-voltage conductor, where the ion source is placed, and high up to 15 atm gas environment pressure

  8. Operation of LIA-30 linear induction accelerator in the mode of generation of two bremsstrahlung pulses

    Energy Technology Data Exchange (ETDEWEB)

    Bossamykin, V S; Gerasimov, A I; Gordeev, V S; Grishin, A V; Gritsina, V P; Tarasov, A D; Fedotkin, A S; Lazarev, S A; Averchenkov, A Ya [All-Russian Scientific Research Institute of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    The operating mode was studied of the LIA-30 linear induction accelerator ({approx} 40 MeV, {approx} 100 kA, {approx} 30 ns) with the generation of two bremsstrahlung pulses separated by a specified time interval from 0 to 5 {mu}s. In the accelerating channel an additional tube cathode was installed, and a synchronization system for two accelerating module groups triggering the formation and acceleration, at different initial times, of two annular electron beams with different outer diameters was changed. The energy limit of each beam electron acceleration can be controlled, and the energy sum limit is {<=} 540 MeV. (author). 2 tabs., 2 figs.

  9. Comparison between fast contrast-enhanced MR angiography and DSA in diagnosing spinal cord vascular malformations

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Fang Chun; Wang Jue; Xiao Yunfeng

    2007-01-01

    Objective: To evaluate the diagnostic and clinical value of fast contrast-enhanced MR angiography (CE-MRA) with elliptic centric phase-encoding in spinal cord vascular malformations. Methods Fast three-dimensional contrast-enhanced MR angiography with elliptic centric phase-encoding and superconducting 1.5T system was applied prospectively in twenty-five consecutive patients with clinically suspected of spinal cord vascular malformations. All cases were performed with selective spinal digital subtraction angiography, including 18 cases treated by surgery and 2 of them with embolization before surgery, MR angiography follow up were undertaken in ten patients after surgery. Comparing fast contrast-enhanced MR angiography with DSA in diagnosing spinal cord vascular malformations included the origin of feeding artery, the feeding artery, the fistula or the nidus, the draining vein, and the vessel image quality based on the gold standard of selective spinal digital subtraction angiography. Results: Surgically proven diseases included spinal arteriovenous malformations(3 cases), spinal cord perimedullary arteriovenous fistulas (5 cases), spinal dural arteriovenous fistulas (8 cases), paravertebral arteriovenous fistulas (1 case), and spontaneous spinal epidural hematomas (2 eases). Comparing with DSA, the accuracy of MR angiography in diagnosing spinal cord vascular malformations; and detecting the origin of the feeding artery, the feeding artery, the shunt or the nidus and the draining vein were 93.8%, 92%, 96.2%, 100% and 100%, respectively. Overall the degree vascular enhencement were judged to be similar(P>0.05), but the vessel continuity of MRA was inferior to DSA (P<0.05). However, 9 cases of MRA showed no abnormal vascular malformation coinciding with those of surgery. Posttreatment MR angiography did not depict any abnormal vessels again. Conclusions: Fast three-dimensional contrast-enhanced MR angiography with elliptic centric phase-encoding may provide

  10. Characterization of the radiation environment at the UNLV accelerator facility during operation of the Varian M6 linac

    International Nuclear Information System (INIS)

    Hodges, M.; Barzilov, A.; Chen, Y.; Lowe, D.

    2016-01-01

    The bremsstrahlung photon flux from the UNLV particle accelerator (Varian M6 model) was determined using MCNP5 code for 3 MeV and 6 MeV incident electrons. Human biological equivalent dose rates due to accelerator operation were evaluated using the photon flux with the flux-to-dose conversion factors. Dose rates were computed for the accelerator facility for M6 linac use under different operating conditions. The results showed that the use of collimators and linac internal shielding significantly reduced the dose rates throughout the facility. It was shown that the walls of the facility, in addition to the earthen berm enveloping the building, provide equivalent shielding to reduce dose rates outside to below the 2 mrem/h limit. - Highlights: • A 3/6 MeV electron accelerator equipped with a high energy x-ray target was studied. • Monte Carlo modeling of photon flux was carried out for three accelerator configurations. • Human biological equivalent doses were evaluated within the accelerator facility building.

  11. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2012. Operation, utilization and technical development of JRR-3, JRR-4, NSRR, Tandem Accelerator and RI Production Facility

    International Nuclear Information System (INIS)

    Murayama, Yoji; Ishii, Tetsuro; Nakamura, Kiyoshi; Uno, Yuki; Ishikuro, Yasuhiro; Kawashima, Kazuhito; Ishizaki, Nobuhiro; Matsumura, Taichi; Nagahori, Kazuhisa; Odauchi, Shouji; Maruo, Takeshi

    2014-03-01

    The Department of Research Reactor and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3(Japan Research Reactor No.3), JRR-4(Japan Research Reactor No.4), NSRR(Nuclear Safety Research Reactor), Tandem Accelerator and RI Production Facility. This annual report describes a summary of activities of services and technical developments carried out in the period between April 1, 2012 and March 31, 2013. The activities were categorized into five service/development fields: (1) Operation and maintenance of research reactors and tandem accelerator, (2) Utilization of research reactors and tandem accelerator, (3) Upgrading of utilization techniques of research reactors and tandem accelerator, (4) Safety administration for department of research reactor and tandem accelerator, (5) International cooperation. Also contained are lists of publications, meetings, granted permissions on laws and regulations concerning atomic energy, number of staff members dispatched to Fukushima for the technical assistance, outcomes in service and technical developments and so on. (author)

  12. Acceleration Modes and Transitions in Pulsed Plasma Accelerators

    Science.gov (United States)

    Polzin, Kurt A.; Greve, Christine M.

    2018-01-01

    Pulsed plasma accelerators typically operate by storing energy in a capacitor bank and then discharging this energy through a gas, ionizing and accelerating it through the Lorentz body force. Two plasma accelerator types employing this general scheme have typically been studied: the gas-fed pulsed plasma thruster and the quasi-steady magnetoplasmadynamic (MPD) accelerator. The gas-fed pulsed plasma accelerator is generally represented as a completely transient device discharging in approximately 1-10 microseconds. When the capacitor bank is discharged through the gas, a current sheet forms at the breech of the thruster and propagates forward under a j (current density) by B (magnetic field) body force, entraining propellant it encounters. This process is sometimes referred to as detonation-mode acceleration because the current sheet representation approximates that of a strong shock propagating through the gas. Acceleration of the initial current sheet ceases when either the current sheet reaches the end of the device and is ejected or when the current in the circuit reverses, striking a new current sheet at the breech and depriving the initial sheet of additional acceleration. In the quasi-steady MPD accelerator, the pulse is lengthened to approximately 1 millisecond or longer and maintained at an approximately constant level during discharge. The time over which the transient phenomena experienced during startup typically occur is short relative to the overall discharge time, which is now long enough for the plasma to assume a relatively steady-state configuration. The ionized gas flows through a stationary current channel in a manner that is sometimes referred to as the deflagration-mode of operation. The plasma experiences electromagnetic acceleration as it flows through the current channel towards the exit of the device. A device that had a short pulse length but appeared to operate in a plasma acceleration regime different from the gas-fed pulsed plasma

  13. Gadopentate dimeglumine enhanced MR angiography (MRA) for staging AAA: a correlation with DSA and CT

    International Nuclear Information System (INIS)

    Arlart, I.P.; Gerlach, A.; Kolb, M.; Erpenbach, S.; Wuerstlin, S.

    1997-01-01

    Purpose: To evaluate a contrast-enhanced (CE) MRA sequence for staging AAA. Methods: In 24 patients (male=20, female=4, age=44-81 y) with known AAA the abdominal aorta and its branches including the iliac arteries were imaged, using a 3D GRE-FISP sequence (1.5 T, T R /T E /FA=25/6/35, slab=100-140 mm, 32 part., FOV=440-450 mm, matrix=256x256) during an i.v. infusion of 40 ml of gadopentate dimeglumine. In addition, representative axial single slices (2D breathhold FLASH-sequence: T R /T E /FA=82/5/30) were acquired following contrast application. MR-results were correlated with i.a. DSA and CT studies. Results: With CE-MRA, AAA (n=24) and iliac aneurysms (n=17) could be evaluated in all cases (sens.=100%, spec.=100%) including luminal patency and mural thrombus. 50/54 renal arteries could be identified, 4/6 accessory renal arteries (sens=66,6%, spec.=100%), 8/9 renal artery stenoses>50% (sens.=88.8%, spec.=89.3%), 1/1 renal artery occlusion and 7/8 iliac artery stenoses>50% (sens.=87.5%, spec.=97.5%) were depicted correctly. Proximal portion of sup. mes. art. could be detected and evaluated in 21/24 cases. Quantitative determination of therapeutically relevant vascular paramters using MRA was comparable to DSA and CT. (orig./AJ) [de

  14. Operational status of the uranium beam upgrade of the ATLAS accelerator

    International Nuclear Information System (INIS)

    Pardo, R.C.; Bollinger, L.M.; Nolen, J.A.

    1993-01-01

    The Positive-Ion Injector (PII) for ATLAS is complete. First beams from the new injector have been accelerated and used for experiments at ATLAS. The PH consists of an ECR ion source on a 350-kV platform and a low-velocity superconducting linac. The first acceleration of uranium for the experimental program has demonstrated the design goals of the project have been met. Since the summer of 1992, the new injecter has been used for the research program approximately 50% of the time. Longitudinal beam quality from the new injector has been measured to be significantly better than comparable beams from the tandem injecter. Changes to the mix of resonators in the main ATLAS accelerator to match better the velocity profile for heavy beams such as uranium are nearly complete and uranium energies up to 6.45 MeV per nucleon have been achieved. The operating experience of the new ATLAS facility will be discussed with emphasis on the measured beam quality as well as achieved beam energies and currents

  15. Non-LTE radiative transfer with lambda-acceleration - Convergence properties using exact full and diagonal lambda-operators

    Science.gov (United States)

    Macfarlane, J. J.

    1992-01-01

    We investigate the convergence properties of Lambda-acceleration methods for non-LTE radiative transfer problems in planar and spherical geometry. Matrix elements of the 'exact' A-operator are used to accelerate convergence to a solution in which both the radiative transfer and atomic rate equations are simultaneously satisfied. Convergence properties of two-level and multilevel atomic systems are investigated for methods using: (1) the complete Lambda-operator, and (2) the diagonal of the Lambda-operator. We find that the convergence properties for the method utilizing the complete Lambda-operator are significantly better than those of the diagonal Lambda-operator method, often reducing the number of iterations needed for convergence by a factor of between two and seven. However, the overall computational time required for large scale calculations - that is, those with many atomic levels and spatial zones - is typically a factor of a few larger for the complete Lambda-operator method, suggesting that the approach should be best applied to problems in which convergence is especially difficult.

  16. Operational Characteristics of an Accelerator Driven Fissile Solution System

    International Nuclear Information System (INIS)

    Kimpland, Robert Herbert

    2016-01-01

    Operational characteristics represent the set of responses that a nuclear system exhibits during normal operation. Operators rely on this behavior to assess the status of the system and to predict the consequences of off-normal events. These characteristics largely refer to the relationship between power and system operating conditions. The static and dynamic behavior of a chain-reacting system, operating at sufficient power, is primarily governed by reactivity effects. The science of reactor physics has identified and evaluated a number of such effects, including Doppler broadening and shifts in the thermal neutron spectrum. Often these reactivity effects are quantified in the form of feedback coefficients that serve as coupling coefficients relating the neutron population and the physical mechanisms that drive reactivity effects, such as fissile material temperature and density changes. The operational characteristics of such nuclear systems usually manifest themselves when perturbations between system power (neutron population) and system operating conditions arise. Successful operation of such systems requires the establishment of steady equilibrium conditions. However, prior to obtaining the desired equilibrium (steady-state) conditions, an approach from zero-power (startup) must occur. This operational regime may possess certain limiting system conditions that must be maintained to achieve effective startup. Once steady-state is achieved, a key characteristic of this operational regime is the level of stability that the system possesses. Finally, a third operational regime, shutdown, may also possess limiting conditions of operation that must be maintained. This report documents the operational characteristics of a ''generic'' Accelerator Driven Fissile Solution (ADFS) system during the various operational regimes of startup, steady-state operation, and shutdown. Typical time-dependent behavior for each operational regime will be illustrated, and key system

  17. Results from the S-DALINAC: one year of operational experience from a superconducting electron accelerator

    International Nuclear Information System (INIS)

    Graef, H.D.; Horn, J.; Hummel, K.D.; Luettge, C.; Richter, A.; Riedorf, T.; Ruehl, K.; Schardt, P.; Spamer, E.; Stiller, A.; Thomas, F.; Titze, O.; Toepper, J.; Weise, H.; Winkler, T.

    1992-01-01

    Since August 1991 the superconducting cw-electron accelerator S-DALINAC at Darmstadt has produced single and multi pass beam which is used for different experiments. At energies below 10 MeV investigations of channeling radiation production and nuclear resonance fluorescence experiments are performed. Single pass operation yielding beam energies up to 40 MeV has been used for tests of the Free Electron Laser (FEL) beamline and for the investigation of spontaneous emission from the undulator. Two and three pass operation at higher energies produces beam for electron scattering experiments,(e,e') and (e,e'x), as well as for the production of channeling radiation. True cw operation allows for energies up to 84 MeV limited by the capacity of the He refrigerator. At higher energies the duty factor has to be reduced and pulse length is on the order of seconds. The successful operation of the entire accelerator was the result of several developments: six accelerating cavities fabricated from RRR = 280 niobium raised the average field gradient to 6 MV/m; the control systems for gun, rf, cavity tuners, and the beam transport system including beam diagnostics have been integrated into a reliable remote control of the S-DALINAC; and computer controlled path length adjustments for the two recirculating beamlines were installed for optimization of the reinjection phase. (Author) fig., tab., 10 refs

  18. An improved cellular automata model for train operation simulation with dynamic acceleration

    Science.gov (United States)

    Li, Wen-Jun; Nie, Lei

    2018-03-01

    Urban rail transit plays an important role in the urban public traffic because of its advantages of fast speed, large transport capacity, high safety, reliability and low pollution. This study proposes an improved cellular automaton (CA) model by considering the dynamic characteristic of the train acceleration to analyze the energy consumption and train running time. Constructing an effective model for calculating energy consumption to aid train operation improvement is the basis for studying and analyzing energy-saving measures for urban rail transit system operation.

  19. 2014 Joint International Accelerator School: Beam Loss and Accelerator Protection

    CERN Document Server

    JAS - Joint US-CERN-Japan-Russia Accelerator School

    2016-01-01

    Many particle accelerators operate with very high beam power and very high energy stored in particle beams as well as in magnet systems. In the future, the beam power in high intensity accelerators will further increase. The protection of the accelerator equipment from the consequences of uncontrolled release of the energy is essential. This was the motivation for organizing a first school on beam losses and accelerator protection (in general referred to as machine protection). During the school the methods and technologies to identify, mitigate, monitor and manage the technical risks associated with the operation of accelerators with high-power beams or subsystems with large stored energy were presented. At the completion of the school the participants should have been able to understand the physical phenomena that can damage machine subsystems or interrupt operations and to analyze an accelerator facility to produce a register of technical risks and the corresponding risk mitigation and management strategie...

  20. Process hazards analysis (PrHA) program, bridging accident analyses and operational safety

    International Nuclear Information System (INIS)

    Richardson, J.A.; McKernan, S.A.; Vigil, M.J.

    2003-01-01

    Recently the Final Safety Analysis Report (FSAR) for the Plutonium Facility at Los Alamos National Laboratory, Technical Area 55 (TA-55) was revised and submitted to the US. Department of Energy (DOE). As a part of this effort, over seventy Process Hazards Analyses (PrHAs) were written and/or revised over the six years prior to the FSAR revision. TA-55 is a research, development, and production nuclear facility that primarily supports US. defense and space programs. Nuclear fuels and material research; material recovery, refining and analyses; and the casting, machining and fabrication of plutonium components are some of the activities conducted at TA-35. These operations involve a wide variety of industrial, chemical and nuclear hazards. Operational personnel along with safety analysts work as a team to prepare the PrHA. PrHAs describe the process; identi fy the hazards; and analyze hazards including determining hazard scenarios, their likelihood, and consequences. In addition, the interaction of the process to facility systems, structures and operational specific protective features are part of the PrHA. This information is rolled-up to determine bounding accidents and mitigating systems and structures. Further detailed accident analysis is performed for the bounding accidents and included in the FSAR. The FSAR is part of the Documented Safety Analysis (DSA) that defines the safety envelope for all facility operations in order to protect the worker, the public, and the environment. The DSA is in compliance with the US. Code of Federal Regulations, 10 CFR 830, Nuclear Safety Management and is approved by DOE. The DSA sets forth the bounding conditions necessary for the safe operation for the facility and is essentially a 'license to operate.' Safely of day-to-day operations is based on Hazard Control Plans (HCPs). Hazards are initially identified in the PrI-IA for the specific operation and act as input to the HCP. Specific protective features important to worker

  1. New screening system for unruptured cerebral aneurysms; Combination of an expert system and DSA examination

    Energy Technology Data Exchange (ETDEWEB)

    Samejima, Hirotsugu; Ushikubo, Yukio; Mizokami, Toru [Toho Univ., Tokyo (Japan). School of Medicine; and others

    1990-08-01

    We have designed a screening system to diagnose unruptured aneurysms, including the use of digital subtraction angiography (DSA). We surveyed 115 patients who had undergone clipping procedures after subarachnoid hemorrhage (SAH) and questioned them with regard to the subjective symptoms. Sixty-eight of 92 patients who returned the questionnaire reported, prior to rupture, headache,eye pain, and neck pain most frequently, and also impairment of extraocular movements, ptosis, visual field defects, and motor and sensory disturbances. Nineteen (47.5%) of 40 patients who had complete pain relief after surgery complained of headache from 1 week to 1 month before SAH. In addition, nine patients (22.5%) complained of headache for several years, and were also pain-free after surgery. For the indication of DSA, we employed an expert system based on fuzzy set theory. Seven groups of parameters are: Group 1, a basic questionnaire concerning age, sex, and past and family histories; Group 2, 15 warning signs selected on the basis of retrospective study; and Groups 3-7, detailed questions concerning each sign. Scoring weights assigned to each condition based on the results of the retrospective study, and threshold values were determined by several neurosurgeons. The certainty factors for intermediate hypotheses were calculated from these weights and threshold values and summed up, from which the conclusion was obtained. Twelve new cases of unruptured cerebral aneurysm were diagnosed using this screening system. This system may improve the ability to diagnose cerebral aneurysms before rupture. (author).

  2. Approach to assurance of reliability of linear accelerator operation observations

    International Nuclear Information System (INIS)

    Bakov, S.M.; Borovikov, A.A.; Kavkun, S.L.

    1994-01-01

    The system approach to solving the task of assuring reliability of observations over the linear accelerator operation is proposed. The basic principles of this method consist in application of dependences between the facility parameters, decrease in the number of the system apparatus channels for data acquisition without replacement of failed channel by reserve one. The signal commutation unit, the introduction whereof into the data acquisition system essentially increases the reliability of the measurement system on the account of active reserve, is considered detail. 8 refs. 6 figs

  3. Statistical analysis of operating efficiency and failures of a medical linear accelerator for ten years

    International Nuclear Information System (INIS)

    Ju, Sang Gyu; Huh, Seung Jae; Han, Young Yih

    2005-01-01

    To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2100C over a ten year period were retrospectively analyzed. The failures were classified according to the involved functional subunits, with each class rated into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for 20% of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and 83% of the expected values, respectively. The operating efficiency was maintained at 95% or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. More rigorous equipment maintenance is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the quality of patient treatment

  4. Operation Manual of the high voltage generator of the Pelletron electron accelerator

    International Nuclear Information System (INIS)

    Hernandez M, V.; Lopez V, H.; Alba P, U.

    1988-04-01

    The first version of a manual to operate the generator of high voltage generator of the Pelletron electron accelerator built in the ININ is presented. Since this generator has several components and/or elements, the one manual present has the purpose that the armed one or maintenance of anyone on its parts, is carried out in an orderly and efficient way. (Author)

  5. TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Balasubramoniam, A; Bednarek, D; Rudin, S; Ionita, C [Toshiba Stroke and Vascular Research Centre, SUNY at Buffalo (United States)

    2016-06-15

    Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  6. TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

    International Nuclear Information System (INIS)

    Balasubramoniam, A; Bednarek, D; Rudin, S; Ionita, C

    2016-01-01

    Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  7. Workshop of the JAEA-Tokai Tandem Accelerator. Memorial of 100,000-hour operation

    International Nuclear Information System (INIS)

    Ishii, Tetsuro; Osa, Akihiko

    2009-04-01

    Workshop of the JAEA-Tokai tandem accelerator has been held every two years. As a memorial of 100,000-hour operation of the tandem accelerator, we have organized the workshop focusing on the activity at this facility. This workshop covers developments and experiments carried out so far, together with experiments in progress and proposals in future. As previous series of workshops, we offered an opportunity to have active discussion among scientists in different fields including accelerator, nuclear physics, nuclear chemistry, radiation effects, atomic physics and so on, aiming at extending facility and research interactively. As a memorial lecture, we invited Dr. Akira Tonomura of fellow of Hitachi, Ltd, a distinctive scientist for development of electron holography. He delivered a lecture titled 'Structure of magnetic flux observed by electron beam'. He once used the tandem accelerator to induce columnar defects in high-temperature superconductor and studied vortices trapped along the defects. Prof. Shigeru Kubono of University of Tokyo, a chairman of program advisory committee of the tandem accelerator, encouraged us through a talk of 'Expectations for the JAEA-Tokai tandem accelerator'. This workshop was held at Advanced Science Research Center Building in Nuclear Science Research Institute on January 6th and 7th in 2009, having 24 oral presentations and 48 posters, and successfully carried out with as many as 120 participants and a lot of science discussions. This review is the collection of slides of oral presentations. The colored slides can be also found in the home page of the tandem accelerator facility (http://rrsys.tokai-sc.jaea.go.jp/rrsys/html/tandem/index.html). (author)

  8. Characterization of the radiation environment at the UNLV accelerator facility during operation of the Varian M6 linac

    Science.gov (United States)

    Hodges, M.; Barzilov, A.; Chen, Y.; Lowe, D.

    2016-10-01

    The bremsstrahlung photon flux from the UNLV particle accelerator (Varian M6 model) was determined using MCNP5 code for 3 MeV and 6 MeV incident electrons. Human biological equivalent dose rates due to accelerator operation were evaluated using the photon flux with the flux-to-dose conversion factors. Dose rates were computed for the accelerator facility for M6 linac use under different operating conditions. The results showed that the use of collimators and linac internal shielding significantly reduced the dose rates throughout the facility. It was shown that the walls of the facility, in addition to the earthen berm enveloping the building, provide equivalent shielding to reduce dose rates outside to below the 2 mrem/h limit.

  9. Study of Operating Parameters for Accelerated Anode Degradation in SOFCs

    DEFF Research Database (Denmark)

    Ploner, Alexandra; Hagen, Anke; Hauch, Anne

    2017-01-01

    Solid oxide fuel cell (SOFC) applications require lifetimes of several years on the system level. A big challenge is to demonstrate such exceptionally long lifetimes in ongoing R&D projects. Accelerated or compressed testing are alternative methods to obtain this. Activities in this area have been...... carried out without arriving at a generally accepted methodology. This is mainly due to the complexity of degradation mechanisms on the single SOFC components as function of operating parameters. In this study, we present a detailed analysis of approx. 180 durability tests regarding degradation of single...... SOFC components as function of operating conditions. Electrochemical impedance data were collected on the fresh and long-term tested SOFCs and used to de-convolute the individual losses of single SOFC cell components – electrolyte, cathode and anode. The main findings include a time-dependent effect...

  10. Fourier mode analysis of slab-geometry transport iterations in spatially periodic media

    International Nuclear Information System (INIS)

    Larsen, E W; Zika, M R

    1999-01-01

    We describe a Fourier analysis of the diffusion-synthetic acceleration (DSA) and transport-synthetic acceleration (TSA) iteration schemes for a spatially periodic, but otherwise arbitrarily heterogeneous, medium. Both DSA and TSA converge more slowly in a heterogeneous medium than in a homogeneous medium composed of the volume-averaged scattering ratio. In the limit of a homogeneous medium, our heterogeneous analysis contains eigenvalues of multiplicity two at ''resonant'' wave numbers. In the presence of material heterogeneities, error modes corresponding to these resonant wave numbers are ''excited'' more than other error modes. For DSA and TSA, the iteration spectral radius may occur at these resonant wave numbers, in which case the material heterogeneities most strongly affect iterative performance

  11. Acute Antibody-Mediated Rejection in Presence of MICA-DSA and Successful Renal Re-Transplant with Negative-MICA Virtual Crossmatch.

    Directory of Open Access Journals (Sweden)

    Yingzi Ming

    Full Text Available The presence of donor-specific alloantibodies (DSAs against the MICA antigen results in high risk for antibody-mediated rejection (AMR of a transplanted kidney, especially in patients receiving a re-transplant. We describe the incidence of acute C4d+ AMR in a patient who had received a first kidney transplant with a zero HLA antigen mismatch. Retrospective analysis of post-transplant T and B cell crossmatches were negative, but a high level of MICA alloantibody was detected in sera collected both before and after transplant. The DSA against the first allograft mismatched MICA*018 was in the recipient. Flow cytometry and cytotoxicity tests with five samples of freshly isolated human umbilical vein endothelial cells demonstrated the alloantibody nature of patient's MICA-DSA. Prior to the second transplant, a MICA virtual crossmatch and T and B cell crossmatches were used to identify a suitable donor. The patient received a second kidney transplant, and allograft was functioning well at one-year follow-up. Our study indicates that MICA virtual crossmatch is important in selection of a kidney donor if the recipient has been sensitized with MICA antigens.

  12. Transport methods: general. 3. An Additive Angular-Dependent Re-balance Acceleration Method for Neutron Transport Equations

    International Nuclear Information System (INIS)

    Cho, Nam Zin; Park, Chang Je

    2001-01-01

    An additive angular-dependent re-balance (AADR) factor acceleration method is described to accelerate the source iteration of discrete ordinates transport calculation. The formulation of the AADR method follows that of the angular-dependent re-balance (ADR) method in that the re-balance factor is defined only on the cell interface and in that the low-order equation is derived by integrating the transport equation (high-order equation) over angular subspaces. But, the re-balance factor is applied additively. While the AADR method is similar to the boundary projection acceleration and the alpha-weighted linear acceleration, it is more general and does have distinct features. The method is easily extendible to DP N and low-order S N re-balancing, and it does not require consistent discretizations between the high- and low-order equations as in diffusion synthetic acceleration. We find by Fourier analysis and numerical results that the AADR method with a chosen form of weighting functions is unconditionally stable and very effective. There also exists an optimal weighting parameter that leads to the smallest spectral radius. The AADR acceleration method described in this paper is simple to implement, unconditionally stable, and very effective. It uses a physically based weighting function with an optimal parameter, leading to the best spectral radius of ρ<0.1865, compared to ρ<0.2247 of DSA. The application of the AADR acceleration method with the LMB scheme on a test problem shows encouraging results

  13. Study of the properties of the operation of an end-type plasma accelerator initiated by electric foil detonation

    International Nuclear Information System (INIS)

    Gol'dberg, M.M.; Vikaruk, A.Ya.; Sokolov, S.V.; Suminov, I.V.

    1986-01-01

    The results of experimental study of an end-type high-current pulsed plasma accelerator initiated by electric foil detonation are presented. The development stages of the process and formation of the flow pinch are examined during accelerator operation. Analytic functions are obtained which determine the origination conditions of the pinch-effect

  14. Imaging anatomy of dorsal pancreatic artery in patients with diabetes: a comparative study between CTA and DSA

    International Nuclear Information System (INIS)

    Lin Yuning; Li Hui; Yang Xizhang; Chen Ziqian; Tan Jianming; Zhong Qun; Yang Li; Wu Zhixian; Li Huimin; Huang Yisheng

    2011-01-01

    Objective: To investigate the clinical value of 64-section CT angiography (CTA) in detecting the origin of dorsal pancreatic artery (DPA). Methods: Ninety-seven consecutive patients with diabetes received transcatheter infusion of autologous bone marrow-derived stem cell transplantation into DPA. Abdominal CTA was performed in 42 patients before angiography. Celiac trunk, splenic, common hepatic and superior mesenteric arteries were reconstructed in order to locate the origin and traveling course of DPA. A routine angiography of both celiac and superior mesenteric arteries was performed for the demonstration of DPA. Further angiography of splenic and gastroduodenal arteries was carried out if necessary. Taking DSA images as the reference standard, the sensitivity, specificity and accuracy of CTA for DPA detection were calculated. Results: DPA was the main supply artery of pancreas in 85.7% patients (36/42). CTA demonstrated the origin of DPA in 35 cases, although one of which was confirmed to be misjudged (false positive). In seven cases CTA could not demonstrate DPA, and DSA proved that 2 of them was misjudged (false negative). The sensitivity,specificity and accuracy of CTA for DPA detection were 94.4%, 83.3% and 92.9%, respectively. Conclusion: 64-section CTA can accurately detect the origin of main supply artery of pancreas, which is of great value in guiding the interventional procedure for pancreatic diseases. (authors)

  15. Acceleration of 14C beams in electrostatic accelerators

    International Nuclear Information System (INIS)

    Rowton, L.J.; Tesmer, J.R.

    1981-01-01

    Operational problems in the production and acceleration of 14 C beams for nuclear structure research in Los Alamos National Laboratory's Van de Graaff accelerators are discussed. Methods for the control of contamination in ion sources, accelerators and personnel are described. Sputter source target fabrication techniques and the relative beam production efficiencies of various types of bound particulate carbon sputter source targets are presented

  16. Solution of the within-group multidimensional discrete ordinates transport equations on massively parallel architectures

    Science.gov (United States)

    Zerr, Robert Joseph

    2011-12-01

    The integral transport matrix method (ITMM) has been used as the kernel of new parallel solution methods for the discrete ordinates approximation of the within-group neutron transport equation. The ITMM abandons the repetitive mesh sweeps of the traditional source iterations (SI) scheme in favor of constructing stored operators that account for the direct coupling factors among all the cells and between the cells and boundary surfaces. The main goals of this work were to develop the algorithms that construct these operators and employ them in the solution process, determine the most suitable way to parallelize the entire procedure, and evaluate the behavior and performance of the developed methods for increasing number of processes. This project compares the effectiveness of the ITMM with the SI scheme parallelized with the Koch-Baker-Alcouffe (KBA) method. The primary parallel solution method involves a decomposition of the domain into smaller spatial sub-domains, each with their own transport matrices, and coupled together via interface boundary angular fluxes. Each sub-domain has its own set of ITMM operators and represents an independent transport problem. Multiple iterative parallel solution methods have investigated, including parallel block Jacobi (PBJ), parallel red/black Gauss-Seidel (PGS), and parallel GMRES (PGMRES). The fastest observed parallel solution method, PGS, was used in a weak scaling comparison with the PARTISN code. Compared to the state-of-the-art SI-KBA with diffusion synthetic acceleration (DSA), this new method without acceleration/preconditioning is not competitive for any problem parameters considered. The best comparisons occur for problems that are difficult for SI DSA, namely highly scattering and optically thick. SI DSA execution time curves are generally steeper than the PGS ones. However, until further testing is performed it cannot be concluded that SI DSA does not outperform the ITMM with PGS even on several thousand or tens of

  17. Quantum Chemical Calculations Using Accelerators: Migrating Matrix Operations to the NVIDIA Kepler GPU and the Intel Xeon Phi.

    Science.gov (United States)

    Leang, Sarom S; Rendell, Alistair P; Gordon, Mark S

    2014-03-11

    Increasingly, modern computer systems comprise a multicore general-purpose processor augmented with a number of special purpose devices or accelerators connected via an external interface such as a PCI bus. The NVIDIA Kepler Graphical Processing Unit (GPU) and the Intel Phi are two examples of such accelerators. Accelerators offer peak performances that can be well above those of the host processor. How to exploit this heterogeneous environment for legacy application codes is not, however, straightforward. This paper considers how matrix operations in typical quantum chemical calculations can be migrated to the GPU and Phi systems. Double precision general matrix multiply operations are endemic in electronic structure calculations, especially methods that include electron correlation, such as density functional theory, second order perturbation theory, and coupled cluster theory. The use of approaches that automatically determine whether to use the host or an accelerator, based on problem size, is explored, with computations that are occurring on the accelerator and/or the host. For data-transfers over PCI-e, the GPU provides the best overall performance for data sizes up to 4096 MB with consistent upload and download rates between 5-5.6 GB/s and 5.4-6.3 GB/s, respectively. The GPU outperforms the Phi for both square and nonsquare matrix multiplications.

  18. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2014. Operation, Utilization and Technical Development of JRR-3, JRR-4, NSRR, Tandem Accelerator and RI Production Facility

    International Nuclear Information System (INIS)

    Osa, Akihiko; Imahashi, Masaki; Hirane, Nobuhiko; Motome, Yuiko; Tayama, Hidekazu; Tamura, Itaru; Harada, Yuko; Sakata, Mami; Kadokura, Masakazu; Takita, Chiharu

    2017-02-01

    The Department of Research Reactor and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3 (Japan Research Reactor No.3), JRR-4 (Japan Research Reactor No.4), NSRR (Nuclear Safety Research Reactor), Tandem Accelerator and RI Production Facility. This annual report describes the activities of our department in fiscal year of 2014. We carried out the operation and maintenance, utilization, upgrading of utilization techniques, safety administration, and international cooperation. Also contained are lists of publications, meetings, granted permissions on laws and regulations concerning atomic energy, outcomes in service and technical developments and so on. (author)

  19. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2013. Operation, Utilization and Technical Development of JRR-3, JRR-4, NSRR, Tandem Accelerator and RI Production Facility

    International Nuclear Information System (INIS)

    Kashima, Yoichi; Murayama, Yoji; Nakamura, Kiyoshi; Uno, Yuki; Hirane, Nobuhiko; Ohuchi, Hitoshi; Ishizaki, Nobuhiro; Matsumura, Taichi; Nagahori, Kazuhisa; Harada, Yuko; Kadokura, Masakazu; Machi, Sumire; Takita, Chiharu

    2015-02-01

    The Department of Research Reactor and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3(Japan Research Reactor No.3), JRR-4(Japan Research Reactor No.4), NSRR(Nuclear Safety Research Reactor), Tandem Accelerator and RI Production Facility. This annual report describes the activities of our department in fiscal year of 2013. We carried out the operation and maintenance, utilization, upgrading of utilization techniques, safety administration and international cooperation. Also contained are lists of publications, meetings, granted permissions on laws and regulations concerning atomic energy, outcomes in service and technical developments and so on. (author)

  20. Collective field accelerator

    International Nuclear Information System (INIS)

    Luce, J.S.

    1978-01-01

    A collective field accelerator which operates with a vacuum diode and utilizes a grooved cathode and a dielectric anode that operates with a relativistic electron beam with a ν/γ of approx. 1, and a plurality of dielectric lenses having an axial magnetic field thereabout to focus the collectively accelerated electrons and ions which are ejected from the anode. The anode and lenses operate as unoptimized r-f cavities which modulate and focus the beam

  1. Charged particle accelerator

    International Nuclear Information System (INIS)

    Arakawa, Kazuo.

    1969-01-01

    An accelerator is disclosed having a device which permits the electrodes of an accelerator tube to be readily conditioned in an uncomplicated manner before commencing operation. In particle accelerators, it is necessary to condition the accelerator electrodes before a stable high voltage can be applied. Large current accelerators of the cockcroft-walton type require a complicated manual operation which entails applying to the electrodes a low voltage which is gradually increased to induce a vacuum discharge and then terminated. When the discharge attains an extremely low level, the voltage is again impressed and again raised to a high value in low current type accelerators, a high voltage power supply charges the electrodes once to induce discharge followed by reapplying the voltage when the vacuum discharge reaches a low level, according to which high voltage is automatically applied. This procedure, however, requires that the high voltage power supply be provided with a large internal resistance to limit the current to within several milliamps. The present invention connects a high voltage power supply and an accelerator tube through a discharge current limiting resistor wired in parallel with a switch. Initially, the switch is opened enabling the power supply to impress a voltage limited to a prescribed value by a suitably chosen resistor. Conditioning is effected by allowing the voltage between electrodes to increase and is followed by closing the switch through which high voltage is applied directly to the accelerator for operation. (K.J. Owens)

  2. CONFERENCE: Computers and accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-01-15

    In September of last year a Conference on 'Computers in Accelerator Design and Operation' was held in West Berlin attracting some 160 specialists including many from outside Europe. It was a Europhysics Conference, organized by the Hahn-Meitner Institute with Roman Zelazny as Conference Chairman, postponed from an earlier intended venue in Warsaw. The aim was to bring together specialists in the fields of accelerator design, computer control and accelerator operation.

  3. Overview of ten-year operation of the superconducting linear accelerator at the Spallation Neutron Source

    Science.gov (United States)

    Kim, S.-H.; Afanador, R.; Barnhart, D. L.; Crofford, M.; Degraff, B. D.; Doleans, M.; Galambos, J.; Gold, S. W.; Howell, M. P.; Mammosser, J.; McMahan, C. J.; Neustadt, T. S.; Peters, C.; Saunders, J. W.; Strong, W. H.; Vandygriff, D. J.; Vandygriff, D. M.

    2017-04-01

    The Spallation Neutron Source (SNS) has acquired extensive operational experience of a pulsed proton superconducting linear accelerator (SCL) as a user facility. Numerous lessons have been learned in its first 10 years operation to achieve a stable and reliable operation of the SCL. In this paper, an overview of the SNS SCL design, qualification of superconducting radio frequency (SRF) cavities and ancillary subsystems, an overview of the SNS cryogenic system, the SCL operation including SCL output energy history and downtime statistics, performance stability of the SRF cavities, efforts for SRF cavity performance recovery and improvement at the SNS, and maintenance activities for cryomodules are introduced.

  4. Overview of ten-year operation of the superconducting linear accelerator at the Spallation Neutron Source

    International Nuclear Information System (INIS)

    Kim, Sang-Ho; Afanador, Ralph; Barnhart, Debra L.; Crofford, Mark T.; Degraff, Brian D.

    2017-01-01

    The Spallation Neutron Source (SNS) has acquired extensive operational experience of a pulsed proton superconducting linear accelerator (SCL) as a user facility. Numerous lessons have been learned in its first 10 years operation to achieve a stable and reliable operation of the SCL. In this paper, an overview of the SNS SCL design, qualification of superconducting radio frequency (SRF) cavities and ancillary subsystems, an overview of the SNS cryogenic system, the SCL operation including SCL output energy history and downtime statistics, performance stability of the SRF cavities, efforts for SRF cavity performance recovery and improvement at the SNS, and maintenance activities for cryomodules are introduced.

  5. Angular Multigrid Preconditioner for Krylov-Based Solution Techniques Applied to the Sn Equations with Highly Forward-Peaked Scattering

    Science.gov (United States)

    Turcksin, Bruno; Ragusa, Jean C.; Morel, Jim E.

    2012-01-01

    It is well known that the diffusion synthetic acceleration (DSA) methods for the Sn equations become ineffective in the Fokker-Planck forward-peaked scattering limit. In response to this deficiency, Morel and Manteuffel (1991) developed an angular multigrid method for the 1-D Sn equations. This method is very effective, costing roughly twice as much as DSA per source iteration, and yielding a maximum spectral radius of approximately 0.6 in the Fokker-Planck limit. Pautz, Adams, and Morel (PAM) (1999) later generalized the angular multigrid to 2-D, but it was found that the method was unstable with sufficiently forward-peaked mappings between the angular grids. The method was stabilized via a filtering technique based on diffusion operators, but this filtering also degraded the effectiveness of the overall scheme. The spectral radius was not bounded away from unity in the Fokker-Planck limit, although the method remained more effective than DSA. The purpose of this article is to recast the multidimensional PAM angular multigrid method without the filtering as an Sn preconditioner and use it in conjunction with the Generalized Minimal RESidual (GMRES) Krylov method. The approach ensures stability and our computational results demonstrate that it is also significantly more efficient than an analogous DSA-preconditioned Krylov method.

  6. Modern operator's consoles for accelerator control at Fermilab

    International Nuclear Information System (INIS)

    Lucas, P.; Cahill, K.; Peters, R.; Smedinghoff, J.

    1991-01-01

    Since the construction of the Tevatron the Fermilab accelerator complex has been controlled from operator's consoles based on PDP-11 computers and interaction with display hardware via Camac. In addition the Linac has been controllable from microprocessor-based local consoles. The new generation of console devices is based on VAXstation computers, networked by Ethernet and Token Ring, and utilizing the X-windows protocol. Under X the physical display (server) can be driven by any network node, and need not be part of the console computer (client). This allows great flexibility in configuring display devices - with X-terminals, Unix workstations, and Macintoshes all having been utilized. Over half of the 800 application programs on the system have been demonstrated to work properly in the new environment. The modern version of a Linac local console runs in a Macintosh. These are networked via Token Ring to Linac local control stations. They provide color graphics and a hard copy capability which was previously lacking

  7. Predicting induced radioactivity for the accelerator operations at the Taiwan Photon Source.

    Science.gov (United States)

    Sheu, R J; Jiang, S H

    2010-12-01

    This study investigates the characteristics of induced radioactivity due to the operations of a 3-GeV electron accelerator at the Taiwan Photon Source (TPS). According to the beam loss analysis, the authors set two representative irradiation conditions for the activation analysis. The FLUKA Monte Carlo code has been used to predict the isotope inventories, residual activities, and remanent dose rates as a function of time. The calculation model itself is simple but conservative for the evaluation of induced radioactivity in a light source facility. This study highlights the importance of beam loss scenarios and demonstrates the great advantage of using FLUKA in comparing the predicted radioactivity with corresponding regulatory limits. The calculated results lead to the conclusion that, due to fairly low electron consumption, the radioactivity induced in the accelerator components and surrounding concrete walls of the TPS is rather moderate and manageable, while the possible activation of air and cooling water in the tunnel and their environmental releases are negligible.

  8. The safe, economical operation of a slightly subcritical reactor and transmutor with a small proton accelerator

    International Nuclear Information System (INIS)

    Takahashi, Hiroshi

    1994-01-01

    I suggest that an accelerator can be used to increase the safety and neutron economy of a power reactor and a transmutor of long-lived radioactive wastes, such as minor actinides and fission products, by providing neutrons for its subcritical operation. Instead of the large subcriticality k=0.9-0.95 which we originally proposed for such transmutor, we propose to use a slightly subcritical reactor, such as k=0.99, which will avoid many of the technical difficulties that are associated with large subcriticality, such as localized power peaking, radiation damage due to injection of medium-energy protons, the high current accelerator, and the requirement for a long beam-expansion section. We analyze the power drop that occurred in Phenix reactor, and show that the operating this reactor in subcritical conditions improves safety. (author). 13 refs., 5 figs

  9. The safe, economical operation of a slightly subcritical reactor and transmutor with a small proton accelerator

    International Nuclear Information System (INIS)

    Takahashi, Hiroshi.

    1994-01-01

    This report describes methods in which an accelerator can be used to increase the safety and neutron economy of a power reactor and transmutor of long-lived radioactive wastes, such as minor actinides and fission products, by providing neutrons for its subcritical operation. Instead of the rather large subcriticality of k=0.9--0.95 which we originally proposed for such a transmutor, we propose to use a slightly subcritical reactor, such as k=0.99, which will avoid many of the technical difficulties that are associated with large subcriticality, such as localized power peaking, radiation damage due to the injection of medium-energy protons, the high current accelerator, and the requirement for a long beam-expansion section. We analyzed the power drop that occurred in Phoenix reactor, and show that the operating this reactor in subcritical condition improves its safety

  10. Radiation protection of the operation of accelerator facilities. On high energy proton and electron accelerators

    International Nuclear Information System (INIS)

    Kondo, Kenjiro

    1997-01-01

    Problems in the radiation protection raised by accelerated particles with energy higher than several hundreds MeV in strong accelerator facilities were discussed in comparison with those with lower energy in middle- and small-scale facilities. The characteristics in the protection in such strong accelerator facilities are derived from the qualitative changes in the interaction between the high energy particles and materials and from quantitative one due to the beam strength. In the former which is dependent on the emitting mechanism of the radiation, neutron with broad energy spectrum and muon are important in the protection, and in the latter, levels of radiation and radioactivity which are proportional to the beam strength are important. The author described details of the interaction between high energy particles and materials: leading to the conclusion that in the electron accelerator facilities, shielding against high energy-blemsstrahlung radiation and -neutron is important and in the proton acceleration, shielding against neutron is important. The characteristics of the radiation field in the strong accelerator facilities: among neutron, ionized particles and electromagnetic wave, neutron is most important in shielding since it has small cross sections relative to other two. Considerations for neutron are necessary in the management of exposure. Multiplicity of radionuclides produced: which is a result of nuclear spallation reaction due to high energy particles, especially to proton. Radioactivation of the accelerator equipment is a serious problem. Other problems: the interlock systems, radiation protection for experimenters and maintenance of the equipment by remote systems. (K.H.). 11 refs

  11. Phenol removal from wastewaters by electrochemical oxidation using boron doped diamond (BDD) and Ti/Ti{sub 0.7}Ru{sub 0.3}O{sub 2} DSA Registered-Sign electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Britto-Costa, P.H.; Ruotolo, L.A.M., E-mail: pluis@ufscar.br [Universidade Federal de Sao Carlos (UFSCAR), SP (Brazil). Dept. de Engenharia Quimica

    2012-10-15

    Industrial wastewater containing non-biodegradable organic pollutants consists of highly toxic effluents whose treatment is necessary due to environmental and economical restrictions. In order to treat these effluents, an electrochemical process using a dimensionally stable anode (DSA Registered-Sign ) and boron-doped diamond (BDD) electrode was studied. The performance of these electrodes for COD removal from aqueous phenol solution was evaluated in the absence and presence of different chloride concentrations. The results showed that DSA Registered-Sign could be successfully used to remove COD when high chloride concentration (3035 mg L{sup -1}Cl{sup -}) and mild current density are employed (50 mA cm{sup -2}). On the other hand, the presence of chloride did not have the same significant effect on the COD depletion rate using BDD; however, under mild conditions (50 mA cm{sup -2}, 0.190 m s{sup -1}), the addition of 607 mg L{sup -1} Cl{sup -} improved the COD removal by approximately 52% after 8 hours of electrolysis. The effect of current density (i) and flow velocity (v) were also studied, and it was verified that they have an important role on the process performance, especially when DSA Registered-Sign is used. (author)

  12. Operation of the graded-β electron test accelerator

    International Nuclear Information System (INIS)

    Fraser, J.S.; McKeown, J.; McMichael, G.E.; Diamond, W.T.

    1976-01-01

    The Electron Test Accelerator has been built to model the behaviour of the high energy portion of a proton linear accelerator which would be suitable for breeding fissile material. The test accelerator and its control systems have been tested at 100% duty factor producing a beam of electrons at 1.5 MeV and currents up to 20 mA where the incident rf power is shared equally between the structure dissipation and the beam loading. The structure has performed satisfactorily in all respects at dissipation power densities up to 5 kW/cell where the mean energy gradient was 1.1 MeV/m. Experiments have been done on the beam loading effects in the coupling of the transmission line to the cavity, the amplitude depression in and phase tilt along the structure, and the phase lag of the structure field. The phase acceptance, the variation of transmission with buncher-accelerator phase shift and the beam energy spread are in qualitative agreement with beam dynamics calculations. (author)

  13. Q-Learning and p-persistent CSMA based rendezvous protocol for cognitive radio networks operating with shared spectrum activity

    Science.gov (United States)

    Watson, Clifton L.; Biswas, Subir

    2014-06-01

    With an increasing demand for spectrum, dynamic spectrum access (DSA) has been proposed as viable means for providing the flexibility and greater access to spectrum necessary to meet this demand. Within the DSA concept, unlicensed secondary users temporarily "borrow" or access licensed spectrum, while respecting the licensed primary user's rights to that spectrum. As key enablers for DSA, cognitive radios (CRs) are based on software-defined radios which allow them to sense, learn, and adapt to the spectrum environment. These radios can operate independently and rapidly switch channels. Thus, the initial setup and maintenance of cognitive radio networks are dependent upon the ability of CR nodes to find each other, in a process known as rendezvous, and create a link on a common channel for the exchange of data and control information. In this paper, we propose a novel rendezvous protocol, known as QLP, which is based on Q-learning and the p-persistent CSMA protocol. With the QLP protocol, CR nodes learn which channels are best for rendezvous and thus adapt their behavior to visit those channels more frequently. We demonstrate through simulation that the QLP protocol provides a rendevous capability for DSA environments with different dynamics of PU activity, while attempting to achieve the following performance goals: (1) minimize the average time-to-rendezvous, (2) maximize system throughput, (3) minimize primary user interference, and (4) minimize collisions among CR nodes.

  14. Theory of factors limiting high gradient operation of warm accelerating structures

    Energy Technology Data Exchange (ETDEWEB)

    Nusinovich, Gregory S. [University of Maryland; Antonsen, Thomas M. [University of Maryland; Kishek, Rami [University of Maryland

    2014-07-25

    This final report summarizes the research performed during the time period from 8/1/2010 to 7/31/2013. It consists of two parts describing our studies in two directions: (a) analysis of factors limiting operation of dielectric-loaded accelerating (DLA) structures where the main problem is the occurrence of multipactor on dielectric surfaces, and (b) studies of effects associated with either RF magnetic or RF electric fields which may cause the RF breakdown in high-gradient metallic accelerating structures. In the studies of DLA structures, at least, two accomplishments should be mentioned: the development of a 3D non-stationary, self-consistent code describing the multipactor phenomena and yielding very good agreement with some experimental data obtained in joint ANL/NRL experiments. In the metallic structures, such phenomena as the heating and melting of micro-particles (metallic dust) by RF electric and magnetic fields in single-shot and rep-rate regimes is analyzed. Also, such processes in micro-protrusions on the structure surfaces as heating and melting due to the field emitted current and the Nottingham effect are thoroughly investigated with the account for space charge of emitted current on the field emission from the tip.

  15. Criteria for choice and use of contrast media in intra-arterial D.S.A

    International Nuclear Information System (INIS)

    Dalla-Palma, L.; Stacul, F.; Pozzi-Mucelli, R.

    1985-01-01

    The authors investigated the optimal characteristics of contrast media for use in intra-arterial DSA. 209 injections in 108 patients were evaluated, most of them in the abdominal and peripheral regions. In order to decrease contrast media osmolarity and obtain an adequate mixing with blood, contrast media with low iodine concentration were injected using the same volumes and flow rates of conventional arteriography. Good results were obtained with ionic contrast media, 100 and 150 mgI/ml. depending on the area investigated. The low concentrations allowed the use of ionic agents with an osmolarity very close to that of the non ionic contrast media: the pain has been eliminated and the heat sensation reduced. Furthermore the comparison with the cost of nonionic agents shows a great saving. (orig.)

  16. FERMILAB ACCELERATOR R&D PROGRAM TOWARDS INTENSITY FRONTIER ACCELERATORS : STATUS AND PROGRESS

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, Vladimir [Fermilab

    2016-11-15

    The 2014 P5 report indicated the accelerator-based neutrino and rare decay physics research as a centrepiece of the US domestic HEP program at Fermilab. Operation, upgrade and development of the accelerators for the near- term and longer-term particle physics program at the Intensity Frontier face formidable challenges. Here we discuss key elements of the accelerator physics and technology R&D program toward future multi-MW proton accelerators and present its status and progress. INTENSITY FRONTIER ACCELERATORS

  17. Accelerator development

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Because the use of accelerated heavy ions would provide many opportunities for new and important studies in nuclear physics and nuclear chemistry, as well as other disciplines, both the Chemistry and Physics Divisions are supporting the development of a heavy-ion accelerator. The design of greatest current interest includes a tandem accelerator with a terminal voltage of approximately 25 MV injecting into a linear accelerator with rf superconducting resonators. This combined accelerator facility would be capable of accelerating ions of masses ranging over the entire periodic table to an energy corresponding to approximately 10 MeV/nucleon. This approach, as compared to other concepts, has the advantages of lower construction costs, lower operating power, 100 percent duty factor, and high beam quality (good energy resolution, good timing resolution, small beam size, and small beam divergence). The included sections describe the concept of the proposed heavy-ion accelerator, and the development program aiming at: (1) investigation of the individual questions concerning the superconducting accelerating resonators; (2) construction and testing of prototype accelerator systems; and (3) search for economical solutions to engineering problems. (U.S.)

  18. The Effects of a Dynamic Spectrum Access Overlay in LTE-Advanced Networks

    Energy Technology Data Exchange (ETDEWEB)

    Juan D. Deaton; Ryan E. lrwin; Luiz A. DaSilva

    2011-05-01

    As early as 2014, wireless network operators spectral capacity will be overwhelmed by a data tsunami brought on by new devices and applications. To augment spectral capacity, operators could deploy a Dynamic Spectrum Access (DSA) overlay. In the light of the many planned Long Term Evolution (LTE) network deployments, the affects of a DSA overlay have not been fully considered into the existing LTE standards. Coalescing many different aspects of DSA, this paper develops the Spectrum Accountability (SA) framework. The SA framework defines specific network element functionality, protocol interfaces, and signaling flow diagrams for LTE to support service requests and enforce rights of responsibilities of primary and secondary users, respectively. We also include a network simulation to quantify the benefits of using DSA channels to augment capacity. Based on our simulation we show that, network operators can benefit up to %40 increase in operating capacity when sharing DSA bands to augment spectral capacity. With our framework, this paper could serve as an guide in developing future LTE network standards that include DSA.

  19. Improved plasma accelerator

    Science.gov (United States)

    Cheng, D. Y.

    1971-01-01

    Converging, coaxial accelerator electrode configuration operates in vacuum as plasma gun. Plasma forms by periodic injections of high pressure gas that is ionized by electrical discharges. Deflagration mode of discharge provides acceleration, and converging contours of plasma gun provide focusing.

  20. Particle size of radioactive aerosols generated during machine operation in high-energy proton accelerators

    International Nuclear Information System (INIS)

    Oki, Yuichi; Kanda, Yukio; Kondo, Kenjiro; Endo, Akira

    2000-01-01

    In high-energy accelerators, non-radioactive aerosols are abundantly generated due to high radiation doses during machine operation. Under such a condition, radioactive atoms, which are produced through various nuclear reactions in the air of accelerator tunnels, form radioactive aerosols. These aerosols might be inhaled by workers who enter the tunnel just after the beam stop. Their particle size is very important information for estimation of internal exposure doses. In this work, focusing on typical radionuclides such as 7 Be and 24 Na, their particle size distributions are studied. An aluminum chamber was placed in the EP2 beam line of the 12-GeV proton synchrotron at High Energy Accelerator Research Organization (KEK). Aerosol-free air was introduced to the chamber, and aerosols formed in the chamber were sampled during machine operation. A screen-type diffusion battery was employed in the aerosol-size analysis. Assuming that the aerosols have log-normal size distributions, their size distributions were obtained from the radioactivity concentrations at the entrance and exit of the diffusion battery. Radioactivity of the aerosols was measured with Ge detector system, and concentrations of non-radioactive aerosols were obtained using condensation particle counter (CPC). The aerosol size (radius) for 7 Be and 24 Na was found to be 0.01-0.04 μm, and was always larger than that for non-radioactive aerosols. The concentration of non-radioactive aerosols was found to be 10 6 - 10 7 particles/cm 3 . The size for radioactive aerosols was much smaller than ordinary atmospheric aerosols. Internal doses due to inhalation of the radioactive aerosols were estimated, based on the respiratory tract model of ICRP Pub. 66. (author)

  1. Construction and operation of a support facilities (Building 729) for operation/testing of a prototype accelerator/storage ring (XLS) and machine shop for the National Synchrotron Light Source at Brookhaven National Laboratory, Upton, New York

    International Nuclear Information System (INIS)

    1992-06-01

    Proposed action is to construct at BNL a 5,600-ft 2 support building, install and operate a prototypic 200 MeV accelerator and a prototypic 700 MeV storage ring within, and to construct and operate a 15 kV substation to power the building. The accelerator and storage ring would comprise the x-ray lithography source or XLS

  2. CEBAF Accelerator Achievements

    International Nuclear Information System (INIS)

    Chao, Y C; Drury, M; Hovater, C; Hutton, A; Krafft, G A; Poelker, M; Reece, C; Tiefenback, M

    2011-01-01

    In the past decade, nuclear physics users of Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) have benefited from accelerator physics advances and machine improvements. As of early 2011, CEBAF operates routinely at 6 GeV, with a 12 GeV upgrade underway. This article reports highlights of CEBAF's scientific and technological evolution in the areas of cryomodule refurbishment, RF control, polarized source development, beam transport for parity experiments, magnets and hysteresis handling, beam breakup, and helium refrigerator operational optimization.

  3. Accelerating the commercialization on new technologies. [free market operation of federal alternate energy sources programs

    Science.gov (United States)

    Kuehn, T. J.; Nawrocki, P. M.

    1978-01-01

    It is suggested that federal programs for hastening the adoption of alternative energy sources must operate within the free market structure. Five phases of the free market commercialization process are described. Federal role possibilities include information dissemination and funding to stimulate private sector activities within these five phases, and federally sponsored procedures for accelerating commercialization of solar thermal small power systems are considered.

  4. Electron accelerator

    International Nuclear Information System (INIS)

    Abramyan.

    1981-01-01

    The USSR produces an electron accelerator family of a simple design powered straight from the mains. The specifications are given of accelerators ELITA-400, ELITA-3, ELT-2, TEUS-3 and RIUS-5 with maximum electron energies of 0.3 to 5 MeV, a mean power of 10 to 70 kW operating in both the pulsed and the continuous (TEUS-3) modes. Pulsed accelerators ELITA-400 and ELITA-3 and RIUS-5 in which TESLA resonance transformers are used are characterized by their compact size. (Ha)

  5. Interacting with accelerators

    International Nuclear Information System (INIS)

    Dasgupta, S.

    1994-01-01

    Accelerators are research machines which produce energetic particle beam for use as projectiles to effect nuclear reactions. These machines along with their services and facilities may occupy very large areas. The man-machine interface of accelerators has evolved with technological changes in the computer industry and may be partitioned into three phases. The present paper traces the evolution of man-machine interface from the earliest accelerators to the present computerized systems incorporated in modern accelerators. It also discusses the advantages of incorporating expert system technology for assisting operators. (author). 8 ref

  6. North-American MP Tandem accelerators

    International Nuclear Information System (INIS)

    Wegner, H.E.; Thieberger, P.

    1977-01-01

    There are six North-American MP Tandem accelerators: Yale; Minnesota; Chalk River; Rochester; and two at Brookhaven. The current status and operating characteristics of these six tandem accelerators are discussed. Upgrade and special improvements of the different machines is reviewed and new developments since the last Electrostatic Conference are discussed in detail. The overall operating characteristics of the different machines during the last year of operation are compared

  7. Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom

    Energy Technology Data Exchange (ETDEWEB)

    King, Deirdre M.; Fagan, Andrew J.; Moran, Carmel M.; Browne, Jacinta E. [Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Dublin 8 (Ireland); Centre for Advanced Medical Imaging (CAMI), St James' s Hospital, Dublin 8 (Ireland); Department of Medical Physics, University of Edinburgh, Edinburgh EH16 4TJ (United Kingdom); Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Dublin 8 (Ireland)

    2011-02-15

    Purpose: A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in patients suffering from RAS are currently ill-defined, with the result that no one imaging modality has emerged as a gold standard technique for screening for this disease. Methods: The phantoms, which contained a range of stenosis values (0%, 30%, 50%, 70%, and 85%), were designed for use with ultrasound, magnetic resonance imaging, x-ray computed tomography, and x-ray digital subtraction angiography. The construction materials used were optimized with respect to their ultrasonic speed of sound and attenuation coefficient, MR relaxometry (T{sub 1},T{sub 2}) properties, and Hounsfield number/x-ray attenuation coefficient, with a design capable of tolerating high-pressure pulsatile flow. Fiducial targets, incorporated into the phantoms to allow for registration of images among modalities, were chosen to minimize geometric distortions. Results: High quality distortion-free images of the phantoms with good contrast between vessel lumen, fiducial markers, and background tissue to visualize all stenoses were obtained with each modality. Quantitative assessments of the grade of stenosis revealed significant discrepancies between modalities, with each underestimating the stenosis severity for the higher-stenosed phantoms (70% and 85%) by up to 14%, with the greatest discrepancy attributable to DSA. Conclusions: The design and construction of a range of anatomically realistic renal artery phantoms containing varying degrees of stenosis is described. Images obtained using the main four diagnostic techniques used to detect RAS were free from artifacts and exhibited adequate contrast

  8. Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom

    International Nuclear Information System (INIS)

    King, Deirdre M.; Fagan, Andrew J.; Moran, Carmel M.; Browne, Jacinta E.

    2011-01-01

    Purpose: A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in patients suffering from RAS are currently ill-defined, with the result that no one imaging modality has emerged as a gold standard technique for screening for this disease. Methods: The phantoms, which contained a range of stenosis values (0%, 30%, 50%, 70%, and 85%), were designed for use with ultrasound, magnetic resonance imaging, x-ray computed tomography, and x-ray digital subtraction angiography. The construction materials used were optimized with respect to their ultrasonic speed of sound and attenuation coefficient, MR relaxometry (T 1 ,T 2 ) properties, and Hounsfield number/x-ray attenuation coefficient, with a design capable of tolerating high-pressure pulsatile flow. Fiducial targets, incorporated into the phantoms to allow for registration of images among modalities, were chosen to minimize geometric distortions. Results: High quality distortion-free images of the phantoms with good contrast between vessel lumen, fiducial markers, and background tissue to visualize all stenoses were obtained with each modality. Quantitative assessments of the grade of stenosis revealed significant discrepancies between modalities, with each underestimating the stenosis severity for the higher-stenosed phantoms (70% and 85%) by up to 14%, with the greatest discrepancy attributable to DSA. Conclusions: The design and construction of a range of anatomically realistic renal artery phantoms containing varying degrees of stenosis is described. Images obtained using the main four diagnostic techniques used to detect RAS were free from artifacts and exhibited adequate contrast to allow

  9. Optimization of accelerator control

    International Nuclear Information System (INIS)

    Vasiljev, N.D.; Mozin, I.V.; Shelekhov, V.A.; Efremov, D.V.

    1992-01-01

    Expensive exploitation of charged particle accelerators is inevitably concerned with requirements of effectively obtaining of the best characteristics of accelerated beams for physical experiments. One of these characteristics is intensity. Increase of intensity is hindered by a number of effects, concerned with the influence of the volume charge field on a particle motion dynamics in accelerator's chamber. However, ultimate intensity, determined by a volume charge, is almost not achieved for the most of the operating accelerators. This fact is caused by losses of particles during injection, at the initial stage of acceleration and during extraction. These losses are caused by deviations the optimal from real characteristics of the accelerating and magnetic system. This is due to a number of circumstances, including technological tolerances on structural elements of systems, influence of measuring and auxiliary equipment and beam consumers' installations, placed in the closed proximity to magnets, and instability in operation of technological systems of accelerator. Control task consists in compensation of deviations of characteristics of magnetic and electric fields by optimal selection of control actions. As for technical means, automatization of modern accelerators allows to solve optimal control problems in real time. Therefore, the report is devoted to optimal control methods and experimental results. (J.P.N.)

  10. A Novel Algorithm for Solving the Multidimensional Neutron Transport Equation on Massively Parallel Architectures

    Energy Technology Data Exchange (ETDEWEB)

    Azmy, Yousry

    2014-06-10

    We employ the Integral Transport Matrix Method (ITMM) as the kernel of new parallel solution methods for the discrete ordinates approximation of the within-group neutron transport equation. The ITMM abandons the repetitive mesh sweeps of the traditional source iterations (SI) scheme in favor of constructing stored operators that account for the direct coupling factors among all the cells' fluxes and between the cells' and boundary surfaces' fluxes. The main goals of this work are to develop the algorithms that construct these operators and employ them in the solution process, determine the most suitable way to parallelize the entire procedure, and evaluate the behavior and parallel performance of the developed methods with increasing number of processes, P. The fastest observed parallel solution method, Parallel Gauss-Seidel (PGS), was used in a weak scaling comparison with the PARTISN transport code, which uses the source iteration (SI) scheme parallelized with the Koch-baker-Alcouffe (KBA) method. Compared to the state-of-the-art SI-KBA with diffusion synthetic acceleration (DSA), this new method- even without acceleration/preconditioning-is completitive for optically thick problems as P is increased to the tens of thousands range. For the most optically thick cells tested, PGS reduced execution time by an approximate factor of three for problems with more than 130 million computational cells on P = 32,768. Moreover, the SI-DSA execution times's trend rises generally more steeply with increasing P than the PGS trend. Furthermore, the PGS method outperforms SI for the periodic heterogeneous layers (PHL) configuration problems. The PGS method outperforms SI and SI-DSA on as few as P = 16 for PHL problems and reduces execution time by a factor of ten or more for all problems considered with more than 2 million computational cells on P = 4.096.

  11. Development of new S-band RF window for stable high-power operation in linear accelerator RF system

    Science.gov (United States)

    Joo, Youngdo; Lee, Byung-Joon; Kim, Seung-Hwan; Kong, Hyung-Sup; Hwang, Woonha; Roh, Sungjoo; Ryu, Jiwan

    2017-09-01

    For stable high-power operation, a new RF window is developed in the S-band linear accelerator (Linac) RF systems of the Pohang Light Source-II (PLS-II) and the Pohang Accelerator Laboratory X-ray Free-Electron Laser (PAL-XFEL). The new RF window is designed to mitigate the strength of the electric field at the ceramic disk and also at the waveguide-cavity coupling structure of the conventional RF window. By replacing the pill-box type cavity in the conventional RF window with an overmoded cavity, the electric field component perpendicular to the ceramic disk that caused most of the multipacting breakdowns in the ceramic disk was reduced by an order of magnitude. The reduced electric field at the ceramic disk eliminated the Ti-N coating process on the ceramic surface in the fabrication procedure of the new RF window, preventing the incomplete coating from spoiling the RF transmission and lowering the fabrication cost. The overmoded cavity was coupled with input and output waveguides through dual side-wall coupling irises to reduce the electric field strength at the waveguide-cavity coupling structure and the possibility of mode competitions in the overmoded cavity. A prototype of the new RF window was fabricated and fully tested with the Klystron peak input power, pulse duration and pulse repetition rate of 75 MW, 4.5 μs and 10 Hz, respectively, at the high-power test stand. The first mass-produced new RF window installed in the PLS-II Linac is running in normal operation mode. No fault is reported to date. Plans are being made to install the new RF window to all S-band accelerator RF modules of the PLS-II and PAL-XFEL Linacs. This new RF window may be applied to the output windows of S-band power sources like Klystron as wells as the waveguide windows of accelerator facilities which operate in S-band.

  12. Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography.

    Science.gov (United States)

    Huang, Xingfu; Chen, Yanjia; Huang, Zheng; He, Liwei; Liu, Shenrong; Deng, Xiaojiang; Wang, Yongsheng; Li, Rucheng; Xu, Dingli; Peng, Jian

    2018-06-01

    Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19-76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff-Parkinson-White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99-177) minutes, the reconstruction time was 6.5 ± 2.9 (3-14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6-20) minutes, and the mapping time was 11.7 ± 8.3 (3-36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.

  13. Nonthermal Radiation from Supernova Remnant Shocks

    Directory of Open Access Journals (Sweden)

    Hyesung Kang

    2013-09-01

    Full Text Available Most of high energy cosmic rays (CRs are thought to be produced by diffusive shock acceleration (DSA at supernova remnants (SNRs within the Galaxy. Fortunately, nonthermal emissions from CR protons and electrons can provide direct observational evidence for such a model and place strong constraints on the complex nonlinear plasma processes in DSA theory. In this study we calculate the energy spectra of CR protons and electrons in Type Ia SNRs, using time-dependent DSA simulations that incorporate phenomenological models for some wave-particle interactions. We demonstrate that the timedependent evolution of the self-amplified magnetic fields, Alfvénic drift, and escape of the highest energy particles affect the energy spectra of accelerated protons and electrons, and so resulting nonthermal radiation spectrum. Especially, the spectral cutoffs in X-ray and γ-ray emission spectra are regulated by the evolution of the highest energy particles, which are injected at the early phase of SNRs. Thus detailed understandings of nonlinear wave-particle interactions and time-dependent DSA simulations of SNRs are crucial in testing the SNR hypothesis for the origin of Galactic cosmic rays.

  14. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    International Nuclear Information System (INIS)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.)

  15. AI systems approach in particle accelerators

    International Nuclear Information System (INIS)

    Kataria, S.K.; Bhagwat, P.V.; Kori, S.A.

    1992-01-01

    The large particle accelerators machines like pelletron accelerator at Tata Institute of Fundamental Research (T.I.F.R) have several levels of controls with operators responsible for overall global control decisions and closed loop feedback controllers for relatively small subsystems of the machines. As the accelerator machines are becoming more complicated and the requirements more stringent, there is a need to provide the operators with an artificial intelligence (AI) system to aid in the tuning the machine and in failure diagnosis. There are few major areas in the pelletron operation, which can be done more efficiently using AI systems approach so that useful beam is available for much more time: 1) Accelerator Conditioning, 2) Accelerator Tuning, and 3) Maintaining the Tune beams. The feasibility study for using expert system for above areas and also for safety evaluation of the various subsystems is carried out. (author). 10 refs., 4 figs

  16. IFMIF accelerators design

    International Nuclear Information System (INIS)

    Mosnier, A.; Ratzinger, U.

    2008-01-01

    The IFMIF requirement for 250 mA current of deuteron beams at a nominal energy of 40 MeV is met by means of two identical continuous wave (CW) 175 MHz linear accelerators running in parallel, each delivering a 125 mA, 40 MeV deuteron beam to the common target. This approach allows to stay within the current capability of present RF linac technology while providing operational redundancy in case of failure of one of the linacs. Each linac comprises a sequence of acceleration and beam transport/matching stages. The ion source generates a 140 mA deuteron beam at 100 keV. A low energy beam transport (LEBT) transfers the deuteron beam from the source to a radio frequency quadrupole (RFQ) cavity. The RFQ bunches and accelerates the 125 mA beam to 5 MeV. The RFQ output beam is injected through a matching section into a drift-tube-linac (DTL) where it is accelerated to the final energy of 40 MeV. In the reference design, the final acceleration stage is a conventional Alvarez-type DTL with post-couplers operating at room temperature. Operation of both the RFQ and the DTL at the same relatively low frequency is essential for accelerating the high current deuteron beam with low beam loss. The primary concern of the IFMIF linacs is the minimization of beam losses, which could limit their availability and maintainability due to excessive activation of the linac and irradiation of the environment. A careful beam dynamics design is therefore needed from the source to the target to avoid the formation of particle halo that could finally be lost in the linac or transfer lines. A superconducting solution for the high energy portion of the linac using, for example, CH-structure or coaxial-type resonators, could offer some advantages, in particular the reduction of operational costs. Careful beam dynamics simulations and comparison tests with beam during the EVEDA phase are however necessary in order to fully assess the technical feasibility of such alternative solutions

  17. Development of a subway operation incident delay model using accelerated failure time approaches.

    Science.gov (United States)

    Weng, Jinxian; Zheng, Yang; Yan, Xuedong; Meng, Qiang

    2014-12-01

    This study aims to develop a subway operational incident delay model using the parametric accelerated time failure (AFT) approach. Six parametric AFT models including the log-logistic, lognormal and Weibull models, with fixed and random parameters are built based on the Hong Kong subway operation incident data from 2005 to 2012, respectively. In addition, the Weibull model with gamma heterogeneity is also considered to compare the model performance. The goodness-of-fit test results show that the log-logistic AFT model with random parameters is most suitable for estimating the subway incident delay. First, the results show that a longer subway operation incident delay is highly correlated with the following factors: power cable failure, signal cable failure, turnout communication disruption and crashes involving a casualty. Vehicle failure makes the least impact on the increment of subway operation incident delay. According to these results, several possible measures, such as the use of short-distance and wireless communication technology (e.g., Wifi and Zigbee) are suggested to shorten the delay caused by subway operation incidents. Finally, the temporal transferability test results show that the developed log-logistic AFT model with random parameters is stable over time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Los Alamos neutral particle transport codes: New and enhanced capabilities

    International Nuclear Information System (INIS)

    Alcouffe, R.E.; Baker, R.S.; Brinkley, F.W.; Clark, B.A.; Koch, K.R.; Marr, D.R.

    1992-01-01

    We present new developments in Los Alamos discrete-ordinates transport codes and introduce THREEDANT, the latest in the series of Los Alamos discrete ordinates transport codes. THREEDANT solves the multigroup, neutral-particle transport equation in X-Y-Z and R-Θ-Z geometries. THREEDANT uses computationally efficient algorithms: Diffusion Synthetic Acceleration (DSA) is used to accelerate the convergence of transport iterations, the DSA solution is accelerated using the multigrid technique. THREEDANT runs on a wide range of computers, from scientific workstations to CRAY supercomputers. The algorithms are highly vectorized on CRAY computers. Recently, the THREEDANT transport algorithm was implemented on the massively parallel CM-2 computer, with performance that is comparable to a single-processor CRAY-YMP We present the results of THREEDANT analysis of test problems

  19. Particle-accelerator decommissioning

    International Nuclear Information System (INIS)

    Opelka, J.H.; Mundis, R.L.; Marmer, G.J.; Peterson, J.M.; Siskind, B.; Kikta, M.J.

    1979-12-01

    Generic considerations involved in decommissioning particle accelerators are examined. There are presently several hundred accelerators operating in the United States that can produce material containing nonnegligible residual radioactivity. Residual radioactivity after final shutdown is generally short-lived induced activity and is localized in hot spots around the beam line. The decommissioning options addressed are mothballing, entombment, dismantlement with interim storage, and dismantlement with disposal. The recycle of components or entire accelerators following dismantlement is a definite possibility and has occurred in the past. Accelerator components can be recycled either immediately at accelerator shutdown or following a period of storage, depending on the nature of induced activation. Considerations of cost, radioactive waste, and radiological health are presented for four prototypic accelerators. Prototypes considered range from small accelerators having minimal amounts of radioactive mmaterial to a very large accelerator having massive components containing nonnegligible amounts of induced activation. Archival information on past decommissionings is presented, and recommendations concerning regulations and accelerator design that will aid in the decommissioning of an accelerator are given

  20. Accelerators for atomic energy research

    International Nuclear Information System (INIS)

    Shibata, Tokushi

    1999-01-01

    The research and educational activities accomplished using accelerators for atomic energy research were studied. The studied items are research subjects, facility operation, the number of master theses and doctor theses on atomic energy research using accelerators and the future role of accelerators in atomic energy research. The strategy for promotion of the accelerator facility for atomic energy research is discussed. (author)

  1. Effectiveness of operation tools developed by KEKB operators

    International Nuclear Information System (INIS)

    Sugino, K.; Satoh, Y.; Kitabayashi, T.

    2004-01-01

    The main tasks of KEKB (High Energy Accelerator Research Organization B-physics) operators are beam tuning and injection, operation logging, monitoring of accelerator conditions and safety management. New beam tuning methods are frequently applied to KEKB in order to accomplish high luminosity. In such a situation, various operation tools have been developed by the operators to realize efficient operation. In this paper, we describe effectiveness of tools developed by the operators. (author)

  2. Status report of pelletron accelerator and ECR based heavy ion accelerator programme

    International Nuclear Information System (INIS)

    Gupta, A.K.

    2015-01-01

    The BARC-TIFR Pelletron Accelerator is completing twenty seven years of round-the-clock operation, serving diverse users from institutions within and outside DAE. Over the years, various developmental activities and application oriented programs have been initiated at Pelletron Accelerator Facility, resulting into enhanced utilization of the accelerator. We have also been pursuing an ECR based heavy ion accelerator programme under XII th Plan, consisting of an 18 GHz superconducting ECR (Electron Cyclotron Resonance) ion source and a room temperature RFQ (Radio Frequency Quadrupole) followed by low and high beta superconducting niobium resonator cavities. This talk will provide the current status of Pelletron Accelerator and the progress made towards the ECR based heavy ion accelerator program at BARC. (author)

  3. Large tandem accelerators

    International Nuclear Information System (INIS)

    Jones, C.M.

    1976-01-01

    The increasing importance of energetic heavy ion beams in the study of atomic physics, nuclear physics, and materials science has partially or wholly motivated the construction of a new generation of tandem accelerators designed to operate at maximum terminal potentials in the range 14 to 30 MV. In addition, a number of older tandem accelerators are now being significantly upgraded to improve their heavy ion performance. Both of these developments have reemphasized the importance of negative heavy ion sources. The new large tandem accelerators are described, and the requirements placed on negative heavy ion source technology by these and other tandem accelerators used for the acceleration of heavy ions are discussed. First, a brief description is given of the large tandem accelerators which have been completed recently, are under construction, or are funded for construction, second, the motivation for construction of these accelerators is discussed, and last, criteria for negative ion sources for use with these accelerators are presented

  4. Possible role of rf melted microparticles on the operation of high-gradient accelerating structures

    Directory of Open Access Journals (Sweden)

    G. S. Nusinovich

    2009-10-01

    Full Text Available High-gradient accelerating structures should operate reliably for a long time. Therefore studies of various processes which may lead to disruption of such an operation are so important. In the present paper, the dissipation of rf electromagnetic energy in metallic microparticles is analyzed accounting for the temperature dependence of the skin depth. Such particles may appear in structures, for example, due to mechanical fracture of irises in strong rf electric fields. It is shown that such microparticles with dimensions on the order of the skin depth, being immersed in the region of strong rf magnetic field, can absorb enough energy in long-pulse operation to be melted. Then, the melted clumps can impinge on the surface of a structure and create nonuniformities leading to field enhancement and corresponding emission of dark current. Results are given for several geometries and materials of microparticles.

  5. Development of Power System for Medium Energy Accelerator

    International Nuclear Information System (INIS)

    Kwon, Hyeok Jung; Kim, Dae Il; Kim, Han Sung; Seol, Kyung Tae; Jang, Ji Ho; Cho, Yong Sub; Hong, In Seok; Kim, Kyung Ryul

    2008-05-01

    The main goal of the studies are to develop a power supply system used for 100MeV proton accelerator and to operate 20MeV accelerator which has been installed in KAERI site. The 100MeV proton accelerator uses RF cavity to accelerate beams and need RF amplifier, klystron. To operate the klystron, a high power pulse power supply is required and the power supply system should have high quality because the reliability of the power supply has critical impact on the overall reliability of accelerator system. Therefore, high power pulse power system and related technology development are inevitable for 100MeV accelerator system development. 20MeV accelerator system has been developed and installed in KAERI site, which will be used as an injector for 100MeV accelerator and supply 20MeV beam to users. A study on the 20MeV accelerator characteristics should be performed to operate the machine efficiently. In addition, this machine can be used as a test bench for developing the 100MeV accelerator components. Therefore, not only the hardware so called 'high voltage power supply', but the related technology of the high quality high voltage power system and man power can be obtained from the results of this studies. The test results of the 20MeV accelerator can be utilized as a basis for efficient operation of 100MeV accelerator and these are the ultimate objective and necessities of the study

  6. Acceleration of radioactive ions

    International Nuclear Information System (INIS)

    Laxdal, R.E.

    2003-01-01

    There is an intense interest world-wide in the use of radioactive ion beams (RIBs) for experiment. In many existing or proposed facilities ions are produced or collected at source potential, ionized and re-accelerated. Within the past year three new ISOL based facilities have added dedicated post-accelerators to deliver accelerated RIBs to experiment. The paper gives an overview of RIB accelerators present and future, and explores the inherent features in the various acceleration methods with an emphasis on heavy ion linacs. The ISAC-I and ISAC-II post-accelerators are discussed as examples. Commissioning results and initial operating experience with ISAC-I will be presented

  7. Charged particle accelerators for practice

    International Nuclear Information System (INIS)

    Arzumanov, A.A.

    1988-01-01

    Characteristics of some accelerators operating in the world are given, capabilities of accelerator technique are demonstrated. Examples of wide application of accelerators in radiation-chemical technology as well as for defectoscopy of massive metal products and impurity ion implantation when producing semiconductor elements are presented. Works on nuclear filter production are characterized by high efficiency. Wide application of synchrotron radiation is described. Various accelerators can be applied during element analysis in geology, metallurgy, ecology. Application of accelerators ''in particular, cyclotrons for radioisotope production as well as in radiotherapy in medicine appears to be important. An isochronous cyclotron with controlled ion energy, at which applied works concerning a number of considered trends in the field of radiation physics and radiation physical metallurgy, element analysis, radiation resistance of electronic circuits and components are conducted, is in operation at the IYaPh of the Kazakh Academy of Sciences. Production of tallium-201 for cardiologic invstigations deserves a special attention. An electrostatic heavy ion accelerator which allows one to produce the beams of accelerated ions of elements from hydrogen to uranium is under commissioning

  8. Development of the accelerating system

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jiho; Kwon, H. J.; Kim, D. I.; Kim, H. S.; Ryu, J. Y.; Park, B. S.; Seol, K. T.; Yun, S. P.; Song, Y. G.; Cho, Y. S.

    2013-02-15

    One of the main purposes of the 'Development of the Accelerating System' is developing a 100-MeV proton linac which accelerate proton beams from 20 MeV to 100 MeV by using 7 DTL (drift tube linac) tanks. Two of them were finished in the 2-nd stage of the project. The remaining part was also successfully fabricated and installed at Gyeongju site of KAERI. The MEBT is an essential component to extract and supply 20-MeV proton beams to users, and to match proton beams to the next accelerating structure for 100-MeV acceleration. The development of the MEBT has successfully finished. The project also developed the digital LLRF (low level RF) system which control the accelerating field within 1% in magnitude and 1 degree in phase. This system has been successfully tested in the 20-MeV linac operation at Daejeon site of KAERI. The modified version of the digital LLRF system will be used in the 100-MeV linac operation. The project also developed the beam diagnostic system. They are the strip-line type beam position monitor (BPM), the beam current monitor (CT), the beam loss monitor (BLM), and the emittance measurement system. They are used to measure the characteristics of the 20-MeV proton beams. The project also developed the EPIC-based control system. It is used to monitor the status of the accelerator and components, and to remotely control accelerator components. It has been used and modified in the 20-MeV linac operation. The modified version of the LLRF, diagnostics and control systems will be used in 100-MeV linac operation.

  9. 2014 CERN Accelerator Schools: Beam Loss and Accelerator Protection

    CERN Multimedia

    2014-01-01

    The US-CERN-JAPAN-RUSSIA Joint International Accelerator School is organising a course on Beam Loss and Accelerator Protection to be held in Newport Beach, California, USA from 5-14 November, 2014.    This school is intended for physicists and engineers who are or may be engaged in the design, construction, and/or operation of accelerators with high power photon or particle beams and/or accelerator sub-systems with large stored energy. Application deadlines are 15 August and 4 September. Further information on this Joint School can be found at: http://cas.web.cern.ch/cas/JAS/Newport%20Beach%202014/NPBadvert.html http://indico.cern.ch/event/287647/ http://uspas.fnal.gov/programs/JAS/JAS14.shtml

  10. Nonlinear dynamics in particle accelerators

    CERN Document Server

    Dilão, Rui

    1996-01-01

    This book is an introductory course to accelerator physics at the level of graduate students. It has been written for a large audience which includes users of accelerator facilities, accelerator physicists and engineers, and undergraduates aiming to learn the basic principles of construction, operation and applications of accelerators.The new concepts of dynamical systems developed in the last twenty years give the theoretical setting to analyse the stability of particle beams in accelerator. In this book a common language to both accelerator physics and dynamical systems is integrated and dev

  11. Particle-beam accelerators for radiotherapy and radioisotopes

    International Nuclear Information System (INIS)

    Boyd, T.J.; Crandall, K.R.; Hamm, R.W.

    1981-01-01

    The philosophy used in developing the new PIGMI technology was that the parameters chosen for physics research machines are not necessarily the right ones for a dedicated therapy or radioisotope machine. In particular, the beam current and energy can be optimized, and the design should emphasize minimum size, simplicity and reliability of operation, and economy in capital and operating costs. A major part of achieving these goals lay in raising the operating frequency and voltage gradient of the accelerator, which shrinks the diameter and length of the components. Several other technical innovations resulted in major system improvements. One of these is a radically new type of accelerator structure named the radio-frequency quadrupole (RFQ) accelerator. This allowed us to eliminate the large, complicated ion source used in previous ion accelerators, and to achieve a very high quality accelerated beam. Also, by using advanced permanent magnet materials to make the focusing elements, the system becomes much simpler. Other improvements have been made in all of the accelerator components and in the methods for operating them. These will be described, and design and costing information examples given for several possible therapy and radioisotope production machines

  12. Application of local area networks to accelerator control systems at the Stanford Linear Accelerator

    International Nuclear Information System (INIS)

    Fox, J.D.; Linstadt, E.; Melen, R.

    1983-03-01

    The history and current status of SLAC's SDLC networks for distributed accelerator control systems are discussed. These local area networks have been used for instrumentation and control of the linear accelerator. Network topologies, protocols, physical links, and logical interconnections are discussed for specific applications in distributed data acquisition and control system, computer networks and accelerator operations

  13. SSC accelerator availability allocation

    International Nuclear Information System (INIS)

    Dixon, K.T.; Franciscovich, J.

    1991-03-01

    Superconducting Super Collider (SSC) operational availability is an area of major concern, judged by the Central Design Group to present such risk that use of modern engineering tools would be essential to program success. Experience has shown that as accelerator beam availability falls below about 80%, efficiency of physics experiments degrades rapidly due to inability to maintain adequate coincident accelerator and detector operation. For this reason, the SSC availability goal has been set at 80%, even though the Fermi National Accelerator Laboratory accelerator, with a fraction of the SSC's complexity, has only recently approached that level. This paper describes the allocation of the top-level goal to part-level reliability and maintainability requirements, and it gives the results of parameter sensitivity studies designed to help identify the best approach to achieve the needed system availability within funding and schedule constraints. 1 ref., 12 figs., 4 tabs

  14. Present status of tandem accelerator in Tsukuba University

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Toyoyuki; Oshima, Hiroyuki; Ishii, Satoshi [Tsukuba Univ., Ibaraki (Japan). Tandem Accelerator Center; and others

    1996-12-01

    The tandem accelerator in Tsukuba University, 12UD Peletron, has continued the operation for 21 years, and the total operation time became 61,822 hours as of the end of March, 1996. In this paper, the state of operation of the tandem accelerator in 1995 and the state of use classified by experimental fields are reported. As for the improvement of peripheral equipment, the renewal of the radiation monitoring system and the new installation of the going-in and out control system for radiation control zones were carried out. In fiscal year 1995, the operation time of the accelerator was 3,966 hours, and ion acceleration time was 3,427 hours or 86%. The renewal and improvement of the accelerator system that had been begun in fiscal year 1989 was completed. Also the operation at highest accelerating voltage 12 MV was carried out for 7 hours. In March, the operation was not done because of the periodic inspection. The state of use of two ion sources for joint utilization is shown, and 20 kinds of ions were used. The state of joint utilization, the troubles and repair, and the renewal and new installation are reported. The plan of installing 1 MV TANDETRON is explained. (K.I.)

  15. Accelerators for energy

    International Nuclear Information System (INIS)

    Inoue, Makoto

    2000-01-01

    A particle accelerator is a device to consume energy but not to produce it. Then, the titled accelerator seems to mean an accelerator for using devices related to nuclear energy. For an accelerator combined to nuclear fissionable fuel, neutron sources are D-T type, (gamma, n) reaction using electron beam type spallation type, and so forth. At viewpoints of powers of incident beam and formed neutron, a spallation type source using high energy proton is told to be effective but others have some advantages by investigation on easy operability, easy construction, combustion with target, energy and directivity of neutron, and so forth. Here were discussed on an accelerator for research on accelerator driven energy system by dividing its researching steps, and on kind, energy, beam intensity, and so forth of an accelerator suitable for it. And, space electric charge effect at beam propagation direction controlled by beam intensity of cyclotron was also commented. (G.K.)

  16. Overview of accelerators in medicine

    International Nuclear Information System (INIS)

    Lennox, A.J.

    1993-06-01

    Accelerators used for medicine include synchrotrons, cyclotrons, betatrons, microtrons, and electron, proton, and light ion linacs. Some accelerators which were formerly found only at physics laboratories are now being considered for use in hospital-based treatment and diagnostic facilities. This paper presents typical operating parameters for medical accelerators and gives specific examples of clinical applications for each type of accelerator, with emphasis on recent developments in the field

  17. The MR imaging and DSA features and embolization therapy of spinal dural arteriovenous fistulae

    International Nuclear Information System (INIS)

    Zhang Hua; Hu Jinqing; Lin Dong; Wu Daming; Wang Dengbin; Yang Yanmin; Cheng Kemin

    2005-01-01

    Objective: To investigate the MR imaging and DSA features together with endovascular embolization of spinal dural arteriovenous fistulae (SDAVF). Methods: Twelve patients with SDAVF underwent both MR imaging and angiography of spinal cord, 4 of them received endovascular embolization. The imaging findings of MRI and angiography in all patients were analyzed. Results: Among 12 cases with SDAVF, 11 cases showed diffuse long T 2 signal, 2 cases demonstrated inhomogeneous maculate enhancement in the spinal cord and 6 cases revealed abnormal vessels in the dorsal spaces of spinal cord on MRI. Angiography of spinal cord showed orifices of all fistulae, draining veins, the extent of lesions, amount of feeding vessels and the angiographic features in all the 12 cases. 4 cases with embolization treatment showed improvement clinically. Conclusions: Angiography of spinal cord is the main method and MRI provides important assistance for diagnosing SDAVF while endovascular embolization is an effective method for the treatment. (authors)

  18. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    Energy Technology Data Exchange (ETDEWEB)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.).

  19. Characterization of arterial stenosis using 3D imaging: comparison between three imaging techniques (MRA, spiral CTA and 3D DSA) and four display methods (MIP, SR, MPVR, VA) in a phantom study

    International Nuclear Information System (INIS)

    Bendib, K.; Poirier, C.; Croisille, P.; Roux, J.P.; Devel, D.; Amiel, M.

    1999-01-01

    Introduction: accurate assessment of arterial stenosis is a major public health issue for the diagnosis and treatment of cardiovascular diseases. The number of imaging techniques and types of software for display of imaging data is increasing. Few studies that compare these different techniques are available in the literature. Materials and methods: using phantoms to reproduce the main types of arterial stenosis, the authors compared three 3D acquisition techniques (MRA, CTA, and 3D DSA) and four types of display methods (MIP, SR, MPVR, and VA). The degree, the shape, and the location of different types of stenoses were analyzed by three experienced observers during two successive readings. Intra- and inter-observer reproducibility were assessed. The results of the various acquisition techniques and display methods also were compared to the digital reference data (CFAO) of the physical phantoms. Results: the degree of intra- and inter-observer reproducibility for the assessment of shape and location of the stenoses was good. Visual assessment of the degree of stenosis showed significant differences between two observers as well as in two readings by one observer. The 3D DSA was the most accurate technique for assessing the degree of stenosis. CTA provided better results than MRA. MPVR provided an accurate assessment of the degree of the stenosis. 3D DSA and CTA assessed stenosis form and localization adequately, with no significant difference; both methods appeared to be more accurate than MRA. SR provided the best information on the eccentric nature of the stenosis. The shape was very well assessed by VA and MPVR. Conclusions: even though 3D DSA is the most accurate acquisition technique for visualization, the combined use of SR and MPVR appears to be the best compromise to describe the morphology and degree of stenosis. Further improvements in automatic 3D image processing could offer a better understanding and increased possibilities for assessing arterial

  20. Impacts of Continuous Electron Beam Accelerator Facility operations on groundwater and surface water: Appendix 9

    International Nuclear Information System (INIS)

    Lee, D.W.

    1986-04-01

    The operation of the proposed Continuous Electron Beam Accelerator Facility (CEBAF) at Newport News, Virginia, is expected to result in the activation and subsequent contamination of water resources in the vicinity of the accelerator. Since the proposed site is located in the headwaters of the watershed supplying Big Bethel Reservoir, concern has been expressed about possible contamination of water resources used for consumption. Data characterizing the surface water and groundwater regime in the site area are limited. A preliminary geotechnical investigation of the site has been completed (LAW 1985). This investigation concluded that groundwater flow is generally towards the southeast at an estimated velocity of 2.5 m/y. This conclusion is based on groundwater and soil boring data and is very preliminary in nature. This analysis makes use of the data and conclusions developed during the preliminary geotechnical investigation to provide an upper-bound assessment of radioactive contamination from CEBAF operations. A site water balance was prepared to describe the behavior of the hydrologic environment that is in close agreement with the observed data. The transport of contamination in the groundwater regime is assessed using a one-dimensional model. The groundwater model includes the mechanisms of groundwater flow, groundwater recharge, radioactive decay, and groundwater activation. The model formulation results in a closed-form, exact, analytic solution of the concentration of contamination in the groundwater. The groundwater solution is used to provide a source term for a surface-water analysis. The surface-water and groundwater models are prepared for steady state conditions such that they represent conservative evaluations of CEBAF operations

  1. Cryogenics of the new superconducting accelerator Nuclotron. The first year under operation

    International Nuclear Information System (INIS)

    Baldin, A.M.; Agapov, N.N.; Belushkin, V.A.; D'yachkov, E.I.; Khodzhibagiyan, G.G.; Kovalenko, A.D.; Kuznetsov, G.L.; Matyushevskij, E.A.; Smirnov, A.A.; Sukhanova, A.K.

    1995-01-01

    The 6 GeV superconducting synchrotron was commissioned in March 1993 at the Laboratory of High Energies of the Joint Institute for Nuclear Research in Dubna. Four runs of the total duration about 1000 hours were provided from March 1993 to March 1994. The cooling of the accelerator magnetic system of 250 meters long was performed by two helium refrigerators with a capacity of 1.6 kw at 4.5 K each. The magnets were refrigerated by a two-phase helium flow. All 160 magnets are connected in parallel to the supply and return helium headers. The description and operational characteristics of the Nuclotron cryogenic system are presented. 7 refs., 5 figs., 1 tab

  2. Development of bipolar pulse accelerator for intense pulsed ion beam acceleration

    International Nuclear Information System (INIS)

    Fujioka, Y.; Mitsui, C.; Kitamura, I.; Takahashi, T.; Masugata, K.; Tanoue, H.; Arai, K.

    2003-01-01

    To improve the purity of an intense pulsed ion beams a new type of pulsed ion beam accelerator named 'bipolar pulse accelerator (BPA)' was proposed. In the accelerator purity of the beam is expected. To confirm the principle of the accelerator experimental system was developed. The system utilizes B y type magnetically insulated acceleration gap and operated with single polar negative pulse. A coaxial gas puff plasma gun placed in the grounded anode was used as an ion source, and source plasma (nitrogen) of current density approx. = 25 A/cm 2 , duration approx. = 1.5 μs was injected into the acceleration gap. The ions are successfully accelerated from the grounded anode to the drift tube by applying negative pulse of voltage 180 kV, duration 60 ns to the drift tube. Pulsed ion beam of current density approx. = 40 A/cm 2 , duration approx. 60 ns was obtained at 42 mm downstream from the anode surface. (author)

  3. SNEAP 80: symposium of Northeastern Accelerator personnel

    International Nuclear Information System (INIS)

    Billen, J.H.

    1980-01-01

    Reports of operations are presented for twenty-seven facilities, along with reports on accelerators in progress, ion sources, insulating gases, charging systems, stripping foils, accelerating tubes, and upgraded accelerator systems

  4. High intensity proton operation at the Brookhaven AGS accelerator complex

    International Nuclear Information System (INIS)

    Ahrens, L.A.; Blaskiewicz, M.; Bleser, E.; Brennan, J.M.; Gardner, C.; Glenn, J.W.; Onillon, E.; Reece, R.K.; Roser, T.; Soukas, A.

    1994-01-01

    With the completion of the AGS rf upgrade, and the implementation of a transition open-quotes jumpclose quotes, all of accelerator systems were in place in 1994 to allow acceleration of the proton intensity available from the AGS Booster injector to AGS extraction energy and delivery to the high energy users. Beam commissioning results with these new systems are presented. Progress in identifying and overcoming other obstacles to higher intensity are given. These include a careful exploration of the stopband strengths present on the AGS injection magnetic porch, and implementation of the AGS single bunch transverse dampers throughout the acceleration cycle

  5. The Accelerator Reliability Forum

    CERN Document Server

    Lüdeke, Andreas; Giachino, R

    2014-01-01

    A high reliability is a very important goal for most particle accelerators. The biennial Accelerator Reliability Workshop covers topics related to the design and operation of particle accelerators with a high reliability. In order to optimize the over-all reliability of an accelerator one needs to gather information on the reliability of many different subsystems. While a biennial workshop can serve as a platform for the exchange of such information, the authors aimed to provide a further channel to allow for a more timely communication: the Particle Accelerator Reliability Forum [1]. This contribution will describe the forum and advertise it’s usage in the community.

  6. Ion extraction capabilities of two-grid accelerator systems

    International Nuclear Information System (INIS)

    Rovang, D.C.; Wilbur, P.J.

    1984-02-01

    An experimental investigation into the ion extraction capabilities of two-grid accelerator systems common to electrostatic ion thrusters is described. This work resulted in a large body of experimental data which facilitates the selection of the accelerator system geometries and operating parameters necessary to maximize the extracted ion current. Results suggest that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 0.5 mm. Impingement-limited performance is shown to depend most strongly on grid separation distance, accelerator hole diameter ratio, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained at small grid separation ratios suggest a new grid operating condition where high beam current per hole levels are achieved at a specified net accelerating voltage. It is shown that this operating condition is realized at an optimum ratio of net-to-total accelerating voltage ratio which is typically quite high. The apparatus developed for this study is also shown to be well suited measuring the electron backstreaming and electrical breakdown characteristics of two-grid accelerator systems

  7. Accelerators for Medical Applications What is so Special?

    CERN Document Server

    Schippers, J.M.

    2016-01-01

    Specific requirements of accelerators for radiation therapy with protons or ions will be discussed. The focus will be on accelerator design, operational and formal aspects. We will discuss the special requirements to reach a high reliability for patient treatments as well as an accurate delivery of the dose at the correct position in the patient using modern techniques like pencil beam scanning. It will be shown that the requirements of the accelerated beam differ from those in a nuclear physics laboratory. The way of operating such a medical device requires not only operators, but also the possibility to have a safe machine operation by non accelerator specialists at different operating sites (treatment rooms). It will be shown that the organisation and role of the control/interlock system can be considered as being the most dedicated in a particle-therapy providing facility.

  8. SNEAP 80: symposium of Northeastern Accelerator personnel

    Energy Technology Data Exchange (ETDEWEB)

    Billen, J.H. (ed.)

    1980-01-01

    Reports of operations are presented for twenty-seven facilities, along with reports on accelerators in progress, ion sources, insulating gases, charging systems, stripping foils, accelerating tubes, and upgraded accelerator systems. (GHT)

  9. Industrial applications of electron beam accelerators

    International Nuclear Information System (INIS)

    Braid, W.G. Jr.

    1976-01-01

    The use of electron beam accelerators for crosslinking polyolefins for shrinking food packaging is discussed. Irradiation procedures, accelerator characteristics, and industrial operations are described

  10. Enhancement of Life Time of the Dimensionally Stable Anode for Copper Electroplating Applications

    Directory of Open Access Journals (Sweden)

    Son Seong Ho

    2017-06-01

    Full Text Available In order to enhance the long-term stability of DSA for copper electroplating process, in the present study, noble metal oxides with excellent electrochemical properties was used and optimum condition was determined the ratio of noble metal oxides, surface pre-treatment of titanium substrate and heat treatment. The effect of the surface pretreatment of titanium substrate and ratio of noble metal oxides were estimated by accelerated test at the highly current density conditions. The lifetime of DSA increase six-fold higher as the oxide thickness of Ta 7 : Ir 3 composition ratio. Under the optimal condition, surface pretreatment led to dramatic increase in the lifetime of DSA.

  11. ACCELERATORS: School prizes

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Dedicated to its goal of encouraging scientists and students to work in the field of particle accelerators, the US Particle Accelerator School (operating since 1981) has switched to a new format. Starting this year, it will offer in alternate years basic accelerator physics plus advanced subjects in both university and symposium styles over four weeks. Expanding the school from two to four weeks gives additional flexibility, and undergraduate participation should be encouraged by university credits being offered for particular courses. In the intervening years, the school will organize six-day topical courses

  12. Basis of medical accelerator. Synchrotron

    International Nuclear Information System (INIS)

    Kawachi, Kiyomitsu

    2014-01-01

    On the synchrotron as a medical accelerator, this paper introduces the basic principle, basic techniques and the like. The accelerator, when synchrotron is adopted as an ion beam radiotherapy system, is the composite accelerator composed of ion sources, injector, and synchrotron. This paper introduces the overall structure of synchrotron, and conceptually explains the basic behavior of high-frequency waves and magnetic field of synchrotron, as well as the deflection electromagnet of medical synchrotron and the operation pattern of high-frequency acceleration system. The types of synchrotron can be classified to the function combination type and function separation type, and this paper introduces the features of each type and various types of synchrotrons. It also explains beam dynamics important for ensuring the stability of beams, with a focus on the coordinate system, vertical movement, and lateral movement. In addition, it explains the incidence and outgoing of beams that are important for properly operating the accelerator, with a focus on their techniques. (A.O.)

  13. An automated computerized methodology for the segmentation of in vivo acquired DSA images: application in the New Zealand hindlimb ischemia model

    International Nuclear Information System (INIS)

    Kagadis, G C; Daskalakis, A; Spyridonos, P; Nikiforidis, G C; Diamantopoulos, A; Samaras, N; Katsanos, K; Karnabatidis, D; Siablis, D; Sourgiadaki, E; Cavouras, D

    2009-01-01

    In-vivo dynamic visualization and accurate quantification of vascular networks is a prerequisite of crucial importance in both therapeutic angiogenesis and tumor anti-angiogenesis studies. A user independent computerized tool was developed, for the automated segmentation and quantitative assessment of in-vivo acquired DSA images. Automatic vessel assessment was performed employing the concept of image structural tensor. Initially, vasculature was estimated according to the largest eigenvalue of the structural tensor. The resulted eigenvalue matrix was treated as gray-matrix from which the vessels were gradually segmented and then categorized in three main sub-groups; large, medium and small-size vessels. The histogram percentiles, corresponding to 85%, 65% and 47% of prime eigenvalue gray-matrix were optimally found to give the thresholds T1, T2 and T3 respectively, for extracting vessels of different size. The proposed methodology was tested on a series of DSA images in both normal rabbits (group A) and in rabbits with experimental induced chronic hindlimb ischemia (group B). As a result an automated computerized tool was developed to process images without any user intervention in either experimental or clinical studies. Specifically, a higher total vascular area and length were calculated in group B compared to group A (p=0.0242 and p=0.0322 respectively), which is in accordance to the fact that significantly more collateral arteries are developed during the physiological response to the stimuli of ischemia.

  14. Annual report of Department of Research Reactors and Tandem Accelerator, JFY2006. Operation, utilization and technical development of JRR-3, JRR-4, NSRR and Tandem Accelerator

    International Nuclear Information System (INIS)

    2007-12-01

    The Department of Research Reactors and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3 (Japan Research Reactor-3), JRR-4 (Japan Research Reactor-4) and NSRR (Nuclear Safety Research Reactor) and Tandem Accelerator. The following services and technical developments were achieved in Japanese Fiscal Year 2006: 1) JRR-3 was operated for 181 days in 7 cycles and JRR-4 for 149 days in 37 cycles to provide neutrons for research and development of in-house and outside users. 2) JRR-3 and JRR-4 were utilized through deliberate coordination as follows, a) Neutron irradiations of 628 materials, for neutron transmutation doping of silicon etc. b) Capsule irradiations of 3,067 samples, for neutron activation analyses etc. c) Neutron beam experiments of 6,338 cases x days. 3) Concerning to the 10 times increasing plan of cold neutron beams from JRR-3, a pressure resistant test model of the high-performance neutron moderator vessel which had been designed to increase cold neutrons twice as much as the present one was fabricated. Various developments for upgrading cold neutron guide tubes with super mirrors were in progress. 4) Boron neutron capture therapy was carried out 34 times using JRR-4. Improved neutron collimators were built to fit well to any irregular outline for cancer around the neck. 5) NSRR carried out 4 times of pulse irradiations of high burn-up MOX fuels and 9 times of un-irradiated fuels to contribute to fuel safety researches. 6) The Tandem Accelerator was operated for 201 days to contribute to the researches of nuclear physics and solid state physics with high energy heavy ions. The new utilization program of sharing beam times with outside users was performed by carrying out 45 days. The beam intensity increasing program with a high performance ion source, in place of the compact one which has been working in the high voltage terminal, has made great progress. (author)

  15. AXEL-2016: Introduction to Particle Accelerators

    CERN Multimedia

    2016-01-01

    AXEL-2016 is the latest in a yearly lecture series on particle accelerators given at CERN within the framework of the 2016 Technical Training Programme. As part of the BE department's Operation group’s shutdown lecture series, this general accelerator physics module has been offered since 2003 as a joint venture between the BE department and the Technical Training team and is open to the wider CERN community.    The lecturer is Rende Steerenberg, deputy leader of the Operation group and PS section leader. Programme: basic mathematics; transverse optics; lattice calculations; resonances; longitudinal motion; transfer lines, injection and ejection; longitudinal and transverse beam instabilities; colliders. A detailed programme is available on the AXEL-2016 webpage. Target audience: designed for technicians who are operating an accelerator or whose work is closely linked to accelerators, but also open to technicians, engineers and physicists interested i...

  16. Role of failure-mechanism identification in accelerated testing

    Science.gov (United States)

    Hu, J. M.; Barker, D.; Dasgupta, A.; Arora, A.

    1993-01-01

    Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.

  17. The electron accelerator Ridgetron

    International Nuclear Information System (INIS)

    Hayashizaki, N.; Hattori, T.; Odera, M.; Fujisawa, T.

    1999-01-01

    Many electron accelerators of DC or RF type have been widely used for electron beam irradiation (curing, crosslinking of polymers, sterilization of medical disposables, preservation of food, etc.). Regardless of the acceleration energy, the accelerators to be installed in industrial facilities, have to satisfy the requires of compact size, low power consumption and stable operation. The DC accelerator is realized very compact in the energy under 300 keV, however, it is large to prevent the discharge of an acceleration column in the energy over 300 keV. The RF electron accelerator Ridgetron has been developed to accelerate the continuous beam of the 0.5-10 MeV range in compact space. It is the first example as an electron accelerator incorporated a ridged RF cavity. A prototype system of final energy of 2.5 MeV has been studied to confirm the feasibility at present

  18. Electrochemical degradation of reactive dyes at different DSA compositions

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rodrigo G. da; Aquino Neto, Sydney; Andrade, Adalgisa R. de, E-mail: ardandra@ffclrp.usp.b [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filosofia Ciencias e Letras. Dept. de Quimica

    2011-07-01

    This paper investigates the electrochemical oxidation of the reactive dyes reactive blue 4 (RB-4) and reactive orange 16 (RO-16) on RuO{sub 2} dimensionally stable anode (DSA) electrodes. Electrolysis was achieved under galvanostatic control as a function of supporting electrolyte and electrode composition. The electrolyses, performed in either the presence or absence of NaCl, were able to promote efficient color removal; moreover, at low chloride concentration (0.01 mol L{sup -1}), total color removal was obtained after just 10 min of electrolysis, and a significant increase in total dye combustion was achieved for all the studied anodes in chloride medium (reaching ca. 80% - chemical oxygen demand - COD removal). No significant enhancement in dye color removal or mineralization was observed upon increasing chloride concentration. The influence of oxide composition on dye elimination seems to be significant in both media (with or without chloride), being Ti/Ru{sub 0.30}Ti{sub 0.70}O{sub 2}, the most active material for organic compound oxidation. The oxygen evolution reaction was shown to be a limiting reaction in both supporting electrolytes; i.e., NaCl and Na{sub 2}SO{sub 4}, and its competition with organic compound oxidation remained an obstacle. The adsorbable organo halogens formation study revealed that there is slight consumption of the undesirable species formed within the first minutes of the electrolysis, being Ti/(RuO{sub 2}){sub 0.70}(Ta{sub 2}O{sub 5}){sub 0.30} the most environmentally friendly composition. Both anode composition and chloride concentration affect the formation of these undesirable compounds. (author)

  19. Accelerators: radiation safety and regulatory compliance

    International Nuclear Information System (INIS)

    Bandyopadhyay, Tapas

    2013-01-01

    Growth of accelerators, both positive ions and electron, is very high in India. This may be because of the wide acceptance of these machines in the industrial purposes, medical uses, material science studies, upcoming ADSS facility and many other reasons. Most of cases for societal uses, accelerators have to be installed in the dense public domain. Accelerators for basic research and development purposes to be installed may in public domain or in isolated site. These accelerators are to be classified into different categories in terms of regulatory compliance. Radiation shield design, HVAC system required to be in place with design so that the dose and effluent discharge in the public domain is within a limit considering different pathways. INDUS I and II at Indore, K-130 and K500 machine at VECC, Pelletron at TIFR, IUAC, BARC, EBC at Mumbai are in operation. Apart from this accelerators, a series of medical accelerators in operation and yet to be operational which are generally producing PET isotopes for the diagnosis purposes. VECC is aiming to operate 30 MeV proton machine with about 500 μA beam current for the production of PET, SPECT isotopes for diagnosis purposes and also therapeutic use in near future. Detail requirement in terms of choice of sites, source term estimation for achieving optimum shield thickness, ventilation system, site layout and planning , radioactive effluent handling both gaseous and liquid, decommission aspects will be discussed. (author)

  20. Accelerators Beyond The Tevatron?

    Energy Technology Data Exchange (ETDEWEB)

    Lach, Joseph; /Fermilab

    2010-07-01

    Following the successful operation of the Fermilab superconducting accelerator three new higher energy accelerators were planned. They were the UNK in the Soviet Union, the LHC in Europe, and the SSC in the United States. All were expected to start producing physics about 1995. They did not. Why?

  1. A high-current racetrack induction accelerator

    International Nuclear Information System (INIS)

    Mondelli, A.; Roberson, C.W.

    1983-01-01

    In this paper, the energy and system scaling laws of the Racetrack Induction Accelerator are determined and its operating principles are discussed. This device is a cyclic accelerator that is capable of multi-kiloamp operation. Long pulse induction linac technology is used to obtain short acceleration times. The accelerator consists of a long-pulse linear induction module and a racetrack beam transport system. For detailed studies of the particle dynamics in a racetrack, a numerical model is required to integrate the fully-relativistic single-particle equations of motion in an externally applied magnetic field. The numerical model is a compromise between the need for a large rotational transform and the need for a reasonable volume within the separatrix

  2. Digital subtraction angiography in cardiac diseases

    International Nuclear Information System (INIS)

    Choi, Deuk Lin; Kim, Ki Jeong

    1986-01-01

    DSA was done in 133 examinations of 128 patients during 2 years consist of 9 examination of IV DSA and 124 examination of selective cardiac DSA after cardiac catheterization. Open heart surgery was performed in 90 patients and 12 patients showed discrepancy between pre-and post operative diagnosis, showing a total 86.7% of diagnostic accuracy with DSA. We experienced the significant reduction in dose of contrast media, 30-40% of dose of conventional cardiac angiography. It is concluded that DSA is useful in the evaluation of septal defects, valvular disease and other congenital heart disease. DSA is an accurate simple and safe method in evaluating of cardiac diseases.

  3. Exact measurement of vascular lumina in digital subtraction arteriography (DSA) during stent implantations and percutaneous transluminal angioplasty (PTA)

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, T [Dept. of Radiology, Univ. of Munich (Germany); Kueffer, G [Dept. of Radiology, Univ. of Munich (Germany); Hahn, D [Dept. of Radiology, Univ. of Munich (Germany)

    1992-06-01

    There are inherent difficulties in using high-resolution DSA in interventional radiology for measuring vascular luminal diameter since enlargement ratios are not constant. We present a system that permits accurate determination of vascular lumen diameters by means of a special angiographic catheter with predefined marking points. The accuracy of this measuring method was explored in tests using phantoms. In vivo practicability of the method was proved in PTA and stent implantations in 39 patients. This method with a maximum error of measurement of 5% appears to provide adequate safety in the choice of suitable dilating balloons and stents in interventional vascular procedures. In follow-up, it permits the accurate measurement of neo-intimal thickness. (orig.)

  4. High-performance control system for a heavy-ion medical accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lancaster, H.D.; Magyary, S.B.; Sah, R.C.

    1983-03-01

    A high performance control system is being designed as part of a heavy ion medical accelerator. The accelerator will be a synchrotron dedicated to clinical and other biomedical uses of heavy ions, and it will deliver fully stripped ions at energies up to 800 MeV/nucleon. A key element in the design of an accelerator which will operate in a hospital environment is to provide a high performance control system. This control system will provide accelerator modeling to facilitate changes in operating mode, provide automatic beam tuning to simplify accelerator operations, and provide diagnostics to enhance reliability. The control system being designed utilizes many microcomputers operating in parallel to collect and transmit data; complex numerical computations are performed by a powerful minicomputer. In order to provide the maximum operational flexibility, the Medical Accelerator control system will be capable of dealing with pulse-to-pulse changes in beam energy and ion species.

  5. High-performance control system for a heavy-ion medical accelerator

    International Nuclear Information System (INIS)

    Lancaster, H.D.; Magyary, S.B.; Sah, R.C.

    1983-03-01

    A high performance control system is being designed as part of a heavy ion medical accelerator. The accelerator will be a synchrotron dedicated to clinical and other biomedical uses of heavy ions, and it will deliver fully stripped ions at energies up to 800 MeV/nucleon. A key element in the design of an accelerator which will operate in a hospital environment is to provide a high performance control system. This control system will provide accelerator modeling to facilitate changes in operating mode, provide automatic beam tuning to simplify accelerator operations, and provide diagnostics to enhance reliability. The control system being designed utilizes many microcomputers operating in parallel to collect and transmit data; complex numerical computations are performed by a powerful minicomputer. In order to provide the maximum operational flexibility, the Medical Accelerator control system will be capable of dealing with pulse-to-pulse changes in beam energy and ion species

  6. The ATOMKI Accelerator Center

    International Nuclear Information System (INIS)

    Biri, S.; Kormany, Z.; Berzi, I.; Hunyadi, M.

    2009-01-01

    In 2009 a new division was established in our institute: the ATOMKI Accelerator Center (AAC). Before this time the facilities and staff of AAC belonged to other departments of the institute. The re-organization however, was necessary. It was understood that the translocation of all the accelerators into a centralized unit is advantageous in numerous fields. Here we just mention some of them. The submission of any instrumentation type proposal (EU or domestic) will be easier and has a higher chance to be supported. The organization and distribution of the beamtimes will be more equal and optimal. The usage of the maintenance and spare tools can became better and cheaper. The operating staff (cca. 20 person) can serve at more than one accelerator and the teams can help each other. The accelerator center actually became a fourth new basic unit of the institute besides the three traditional scientific divisions (see the Atomki homepage for the organization chart). The following six main facilities belong to the accelerator center: Cyclotron; VdG-5 accelerator; VdG-1 accelerator; ECR ion source; Isotope separator; Tandetron (under installation). In figure 1 the placements of these machines are shown in an artistic 3D map of the Atomki. The table 1 summarizes the main parameters of the accelerators. More detailed technical specification of the machines can be found in the new homepage of the center. In 2009 all the accelerators operated as scheduled, safely and without major breakdowns. After the experiences in the first months it can be concluded that the new center works well both for technical and human point of views. In the next sub-chapters the 2009 operation and development details of the individual accelerators are summarized. Cyclotron operation. The operation of the cyclotron in 2009 was concentrated to the usual 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 2009 hours; the time

  7. Modern accelerators in ancient Rome

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    For the first time, the achievements and hopes of the broad European accelerator community were brought together in a European Particle Accelerator Conference, held in Rome in June. Ranging from the vast machines at CERN to the small medical accelerators operating in thousands of hospitals, the programme underlined how modern civilization has benefited from the ability to handle charged particle beams

  8. Modern accelerators in ancient Rome

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1988-09-15

    For the first time, the achievements and hopes of the broad European accelerator community were brought together in a European Particle Accelerator Conference, held in Rome in June. Ranging from the vast machines at CERN to the small medical accelerators operating in thousands of hospitals, the programme underlined how modern civilization has benefited from the ability to handle charged particle beams.

  9. Large electrostatic accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.

    1984-01-01

    The increasing importance of energetic heavy ion beams in the study of atomic physics, nuclear physics, and materials science has partially or wholly motivated the construction of a new generation of large electrostatic accelerators designed to operate at terminal potentials of 20 MV or above. In this paper, the author briefly discusses the status of these new accelerators and also discusses several recent technological advances which may be expected to further improve their performance. The paper is divided into four parts: (1) a discussion of the motivation for the construction of large electrostatic accelerators, (2) a description and discussion of several large electrostatic accelerators which have been recently completed or are under construction, (3) a description of several recent innovations which may be expected to improve the performance of large electrostatic accelerators in the future, and (4) a description of an innovative new large electrostatic accelerator whose construction is scheduled to begin next year. Due to time and space constraints, discussion is restricted to consideration of only tandem accelerators.

  10. Large electrostatic accelerators

    International Nuclear Information System (INIS)

    Jones, C.M.

    1984-01-01

    The increasing importance of energetic heavy ion beams in the study of atomic physics, nuclear physics, and materials science has partially or wholly motivated the construction of a new generation of large electrostatic accelerators designed to operate at terminal potentials of 20 MV or above. In this paper, the author briefly discusses the status of these new accelerators and also discusses several recent technological advances which may be expected to further improve their performance. The paper is divided into four parts: (1) a discussion of the motivation for the construction of large electrostatic accelerators, (2) a description and discussion of several large electrostatic accelerators which have been recently completed or are under construction, (3) a description of several recent innovations which may be expected to improve the performance of large electrostatic accelerators in the future, and (4) a description of an innovative new large electrostatic accelerator whose construction is scheduled to begin next year. Due to time and space constraints, discussion is restricted to consideration of only tandem accelerators

  11. Operation Statistics of the CERN Accelerators Complex for 2003

    CERN Document Server

    CERN. Geneva; Baird, S A; Rey, A; Steerenberg, R; CERN. Geneva. AB Department

    2004-01-01

    This report gives an overview of the performance of the different Accelerators (Linacs, PS Booster, PS, AD and SPS) of the CERN Accelerator Complex for 2003. It includes scheduled activities, beam availabilities, beam intensities and an analysis of faults and breakdowns by system and by beam. MORE INFORATION by using the OP Statistics Tool: http://eLogbook.web.cern.ch/eLogbook/statistics.php and on the SPS HomePage: http://ab-div-op-sps.web.cern.ch/ab-div-op-sps/SPSss.html

  12. Future accelerators in Japan

    International Nuclear Information System (INIS)

    Toge, Nobu

    1993-01-01

    This paper presents a brief report on the present status of future accelerator projects at the National Laboratory for High Energy Physics (KEK), Japan. The KEK laboratory has been successfully operating the TRISTAN accelerator complex since 1986. It consists of a 2.5 GeV electron/positron linac, an 8 GeV Accumulation Ring (AR) and a 29 GeV Main Ring (MR). Concurrently with this operation, in response to recommendations by the Japanese High Energy Physics Committee, survey studies have been continued on new accelerator facilities at KEK. They have two major future projects, namely, the asymmetric e + e - B-factory based on TRISTAN (TRISTAN-II) and the Japan Linear Collider (JLC). The purpose of this paper is to outline those research activities and to present an update on their status

  13. Results from the RACE [Ring ACceleration Experiment] Compact Torus Acceleration Experiment

    International Nuclear Information System (INIS)

    Hammer, J.H.; Hartman, C.W.; Eddleman, J.L.; Kusse, B.

    1987-06-01

    RACE (Ring ACceleration Experiment) is a proof-of-principle experiment aimed at demonstrating acceleration of magnetically confined compact torus plasma rings to directed kinetic energies well in excess of their magnetic and thermal energies. In the course of the first year of operation the following have been observed: successful formation of rings in the RACE geometry; acceleration of rings with large forces, F/sub accelerate/ ∼F/sub equilibrium/ without apparent degradation of the ring structure; peak velocities of ≅2.5 x 10 8 cm/sec; acceleration efficiency of >30% at speeds of 1.5 x 10 8 cm/sec inferred from trajectory and capacitor bank data; kinetic to magnetic energy ratios ∼10 were observed. Experiments in the near future will be aimed at confirmation of the mass/energy measurements by calorimetry and direct density measurements

  14. Status of accelerator development at Fermilab

    International Nuclear Information System (INIS)

    Owen, C.W.

    1976-01-01

    The Fermilab accelerator is comprised of four major systems: the high-energy beam-extraction and switching system, the main accelerator (main ring), the booster, and the linear accelerator. The Fermilab accelerator produces accelerated beams for a vigorous international high-energy physics program. The basic design features and operation for high-energy physics have been described a number of times in the past. A report is given which, for the most part, discusses in detail only those features that are particularly significant in increasing the usefulness of the accelerator as a tool for high-energy physics

  15. Switching the JLab Accelerator Operations Environment from an HP-UX Unix-based to a PC/Linux-based environment

    International Nuclear Information System (INIS)

    Mcguckin, Theodore

    2008-01-01

    The Jefferson Lab Accelerator Controls Environment (ACE) was predominantly based on the HP-UX Unix platform from 1987 through the summer of 2004. During this period the Accelerator Machine Control Center (MCC) underwent a major renovation which included introducing Redhat Enterprise Linux machines, first as specialized process servers and then gradually as general login servers. As computer programs and scripts required to run the accelerator were modified, and inherent problems with the HP-UX platform compounded, more development tools became available for use with Linux and the MCC began to be converted over. In May 2008 the last HP-UX Unix login machine was removed from the MCC, leaving only a few Unix-based remote-login servers still available. This presentation will explore the process of converting an operational Control Room environment from the HP-UX to Linux platform as well as the many hurdles that had to be overcome throughout the transition period

  16. Illinois Accelerator Research Center

    Science.gov (United States)

    Kroc, Thomas K.; Cooper, Charlie A.

    The Illinois Accelerator Research Center (IARC) hosts a new accelerator development program at Fermi National Accelerator Laboratory. IARC provides access to Fermi's state-of-the-art facilities and technologies for research, development and industrialization of particle accelerator technology. In addition to facilitating access to available existing Fermi infrastructure, the IARC Campus has a dedicated 36,000 ft2 Heavy Assembly Building (HAB) with all the infrastructure needed to develop, commission and operate new accelerators. Connected to the HAB is a 47,000 ft2 Office, Technology and Engineering (OTE) building, paid for by the state, that has office, meeting, and light technical space. The OTE building, which contains the Accelerator Physics Center, and nearby Accelerator and Technical divisions provide IARC collaborators with unique access to world class expertise in a wide array of accelerator technologies. At IARC scientists and engineers from Fermilab and academia work side by side with industrial partners to develop breakthroughs in accelerator science and translate them into applications for the nation's health, wealth and security.

  17. The 12UD Pelletron accelerator at the University of Tsukuba

    International Nuclear Information System (INIS)

    Seki, S.; Furuno, K.; Ishihara, T.; Nagashima, Y.; Yamanouchi, M.; Aoki, T.; Mikumo, T.; Sanada, J.; Tsukuba Univ., Sakura, Ibaraki

    1981-01-01

    The 12 UD Pelletron installed at the Tandem Accelerator Center of the University of Tsukuba has been in operation for nearly four years. The installation of the accelerator is described and the operational experience with the accelerator and associate facilities are summarized. (orig.)

  18. Collaboration tools for the global accelerator network Workshop Report

    CERN Document Server

    Agarwal, D; Olson, J

    2002-01-01

    The concept of a ''Global Accelerator Network'' (GAN) has been put forward as a means for inter-regional collaboration in the operation of internationally constructed and operated frontier accelerator facilities. A workshop was held to allow representatives of the accelerator community and of the collaboratory development community to meet and discuss collaboration tools for the GAN environment. This workshop, called the Collaboration Tools for the Global Accelerator Network (GAN) Workshop, was held on August 26, 2002 at Lawrence Berkeley National Laboratory. The goal was to provide input about collaboration tools in general and to provide a strawman for the GAN collaborative tools environment. The participants at the workshop represented accelerator physicists, high-energy physicists, operations, technology tool developers, and social scientists that study scientific collaboration.

  19. Collaboration tools for the global accelerator network: Workshop Report

    International Nuclear Information System (INIS)

    Agarwal, Deborah; Olson, Gary; Olson, Judy

    2002-01-01

    The concept of a ''Global Accelerator Network'' (GAN) has been put forward as a means for inter-regional collaboration in the operation of internationally constructed and operated frontier accelerator facilities. A workshop was held to allow representatives of the accelerator community and of the collaboratory development community to meet and discuss collaboration tools for the GAN environment. This workshop, called the Collaboration Tools for the Global Accelerator Network (GAN) Workshop, was held on August 26, 2002 at Lawrence Berkeley National Laboratory. The goal was to provide input about collaboration tools in general and to provide a strawman for the GAN collaborative tools environment. The participants at the workshop represented accelerator physicists, high-energy physicists, operations, technology tool developers, and social scientists that study scientific collaboration

  20. Complex calculation and improvement of beam shaping and accelerating system of the ''Sokol'' small-size electrostatic accelerator

    International Nuclear Information System (INIS)

    Simonenko, A.V.; Pistryak, V.M.; Zats, A.V.; Levchenko, Yu.Z.; Kuz'menko, V.V.

    1987-01-01

    Features of charged particle accelerated beam shaping in the electrostatic part of the ''Sokol'' small-size accelerator are considered in complex taking into account the electrode real geometry. Effect of the extracting, accelerating electorde potential and accelerator total voltage on beam behaviour is investigated. A modified variation of the beam shaping system, allowing to decrease 2 times the required interval of accelerating electrode potential adjustment and to decrease the beam size in the starting acceleration region, is presented. It permits to simplify the construction and to improve accelerator operation. Comparison of experimental and calculational data on the beam in the improved accelerator variation is carried out. Effect of peripheral parts of accelerating tube electrodes on the beam is investigated

  1. Effects of traction on the blood circulation of femoral head: DSA study on a canine model

    International Nuclear Information System (INIS)

    Yang Xiujun; Xiao Jian; Ren Qile; Fu Shiping; Li Wei; Xiao Xiangsheng

    2010-01-01

    Objective: To study the influence of traction on the blood circulation of femur head and its evaluation by DSA. Methods: Using micro-catheter, transfemoral selective femoral circumflex arteriography in 22 healthy dogs was performed in unilateral hip before (Group A, n=22) and immediately (Group B, n=22), 30 (Group D, n=22), 60 (Group E, n=20), 90 (Group F, n=10), 120 (Group G, n= 10) minutes during 2 kg skin hip traction, and immediately after traction removal (Group H, I, J, L and O) , and 30 minutes after traction removal with 60, 90 and 120 minutes continuous traction (Group K, M and P) , and 60 minutes after traction removal with 90 and 120 minutes continuous traction (Group N and Q). DSA was also performed immediately during 4 kg weight traction before continuous traction in 12 hips (Group C). Blood circulation of the femoral head was evaluated mainly by observing its perfusion and time of circulation. Femur head perfusion was assessed as good scoring 3, poor scoring 2 and extremely poor scoring 1. Femur head circulation time was assessed as normal scoring 3, prolonged scoring 2 and remarkably prolonged scoring 1. Analysis of variance was employed for analysis of the angiographic findings between different groups. Results: Good femoral head perfusion in Group A to Q was 22, 0, 0, 0, 0, 0, 0, 22, 22, 1, 18, 0, 0, 8, 0, 0 and 1 hips respectively, poor one was 0, 22, 8, 22, 15, 4, 1, 0, 0, 15, 2, 4, 6, 2, 1, 3 and 8 hips, respectively, extremely poor one was 0, 0, 4, 0, 5, 6, 9, 0, 0, 4, 0, 6, 4, 0, 9, 7 and 1 hips, respectively; and normal femoral head blood circulation time was 22, 0, 0, 0, 0, 0, 0, 22, 22, 1, 18, 0, 0, 8, 0, 0 and 1 hips, respectively, prolonged one was 0, 22, 9, 22, 15, 4, 2, 0, 0, 15, 2, 5, 7, 2, 2, 4 and 8 hips, respectively, remarkably prolonged one was 0, 0, 3, 0, 5, 6, 8, 0, 0, 4, 0, 5, 3, 0, 8, 6 and 1 hips, respectively. F value of femoral head perfusion among group A and B,group B and C, group B, D, E, F and G, Group H, I, J, L and O

  2. Summary report on large HVEC accelerators

    International Nuclear Information System (INIS)

    Thieberger, P.

    1981-01-01

    The main features are described of the ten presently operating large HVEC tandem accelerators and of four additional HVEC accelerators which are in different stages of testing, construction or planning. Present performance characteristics are discussed as well as available information about long term reliability. Some recent improvements are mentioned and comparisons are drawn for acceleration tube gradients in various different configurations and accelerators. Finally, some possible future developments are indicated

  3. Conception, construction, and taking into operation of a pre-accelerator system at ELSA; Konzeption, Aufbau und Inbetriebnahme eines neuen Vorbeschleunigersystems an ELSA

    Energy Technology Data Exchange (ETDEWEB)

    Klarner, Fabian

    2011-11-25

    In order to enhance the operating capabilities of the Bonn University Accelerator Facility ELSA by a single pulse mode, a new injector was designed, built up and successfully commissioned. In addition, the new injector was designed to provide an unpolarized electron beam with increased current to the external hadron physics experiments. For this purpose, the injector will produce an 1-3 microseconds long pulse of 900 mA beam current or a single electron bunch with 1.5 A pulse current. For single bunch operation, a 1.5 ns long pulse is produced by a thermal electron source, then compressed and pre-accelerated by a subsequent resonator and a four-cell travelling wave buncher. After acceleration of the electrons in the main linac, the natural broadening of the energy distribution in the particle ensemble due to the acceleration process will be reduced by an energy compressor system. By the succeeding optical elements in the transfer beamline, the beam is guided to the synchrotron, taking into account the requirements for injection into the synchrotron including its acceptance. Finally, the first beam of the new LINAC1 section was successfully used to irradiate ammonia for preparation as polarized target material for the COMPASS experiment and to irradiate detector components of the DEPFET project. (orig.)

  4. Measurements of electron beam emittance in the Accelerator Test Facility damping ring operated in multibunch modes

    Directory of Open Access Journals (Sweden)

    Yosuke Honda

    2003-09-01

    Full Text Available We present the measurement results of electron beam emittance in the Accelerator Test Facility damping ring operated in multibunch modes. The measurements were carried out with an upgraded laser wire beam profile monitor. The monitor has now a vertical wire as well as a horizontal one and is able to make much faster measurements thanks to an increased effective laser power inside the cavity. The measured emittance shows no large bunch-to-bunch dependence in either the horizontal or vertical directions. The values of the vertical emittance are similar to those obtained in the single-bunch operation. The present results are an important step toward the realization of a high-energy linear collider.

  5. Optical klystron FELs based on tandem electrostatic accelerators

    International Nuclear Information System (INIS)

    Gover, A.; Friedman, A.

    1989-01-01

    The operation of tandem electrostatic accelerator FELs in an optical klystron configuration makes it possible to take advantage of the high quality (low emittance and low energy spread) of the electron beam in electrostatic accelerators. With evolving microwiggler technology, state-of-the-art moderate energy (6-14-MeV) tandem electrostatic accelerators may be used for the development of highly coherent tunable radiation sources in the entire IR region. The authors present the general design considerations and the predicted operating characteristics of such devices and refer in specifics to a design of a 10-1000-μm FEL based on the parameters of a 5-6-MeV high current tandem accelerator. The operating wavelength of FELs is determined by the Doppler shift formula

  6. Evaluation of angiographic delayed vasospasm due to ruptured aneurysm in comparison with cerebral circulation time measured by IA-DSA

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Yoshikazu; Shima, Takeshi; Nishida, Masahiro; Yamane, Kanji; Okita, Shinji; Hatayama, Takashi; Yoshida, Akira; Naoe, Yasutaka; Shiga, Naoko (Chugoku Rosai Hospital, Hiroshima (Japan))

    1994-05-01

    Delayed vasospasm due to ruptured aneurysm has been basically evaluated by angiographic changes in contrast to clinical features such as delayed ischemic neurological deficits (DIND). However, the discrepancies between angiographic and clinical findings have been pointed out. In this study, angiographic changes and cerebral circulation time in ruptured aneurysms were simultaneously investigated with IA-DSA. Thirty-two patients, who had ruptured aneurysms at the anterior circle of Willis and neck clippings at the acute stage, were investigated. Carotid angiogram was performed with IA-DSA on the 7-13th day after the attack. Angiographic changes were evaluated by Fischer's classification and circulation time was calculated in the following way. A time-density curve was obtained at the two ROI's: the C3-C4 portion and the rolandic vein. Circulation time was defined by the difference between the time showing peak optical density at the carotid and the venous portion. The control value of this circulation time obtained from 20 cases with non-rupture aneurysm and epilepsy was 3.4 sec (53 year old) on the average. X-ray CT scan examination was performed at the same time and clinical features were observed every day. Angiographically, 3 cases were free from vasospasm, 18 cases were found to present slight to moderate vasospasm, and 11 cases showed severe vasospasm. Circulation time in patients with no spasm was 3.6 seconds, in patients with slight to moderate vasospasm it was 4.3 seconds and in patients with severe vasospasm it was 6.8 seconds. Ten patients showing cerebral infarction on CT scans demonstrated significantly long circulation time, 7.0 seconds on the average. And all patients having severe vasospasm with circulation time more than 6 seconds presented DIND such as hemiparesis. (author).

  7. Molecular ion acceleration using tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Yuichi; Mizuhashi, Kiyoshi; Tajima, Satoshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1996-12-01

    In TIARA compound beam radiation system, cluster beams have been produced using 3 MV tandem accelerator (9SDH-2) to supply them to various radiation on injection experiments. Till now, productions of C{sub 2-8}, Si{sub 2-4} and O{sub 2} and their accelerations up to 6 MeV have been succeeded. This study aimed at production and acceleration of B{sub 2-4} and LiF. Anion clusters were produced using the conventional ion source of cesium sputter type. The proportions of atoms, molecules and clusters elicited from the ion source were varied depending on the material`s properties and the operating conditions of ion source such as sample temperature, sputter voltage and the shape of sample. The anion clusters were accelerated toward the high voltage terminal in the center of tandem accelerator, leading to cations through losing their electrons by the collision to N{sub 2} gas in a charge conversion cell at the terminal. Positively charged cluster ions could be obtained by modulating the pressure of N{sub 2} gas. Thus, B{sub 2} (64 nA), B{sub 3} (4.4 nA) and B{sub 4} (2.7 nA) have been produced and their maximum survival probabilities were higher than those of carbon or silicon clusters. In addition, the relationship between beam current and gas pressure was investigated for Bn (n = 2-4) and LiF. (M.N.)

  8. Accelerator Toolbox for MATLAB

    International Nuclear Information System (INIS)

    Terebilo, Andrei

    2001-01-01

    This paper introduces Accelerator Toolbox (AT)--a collection of tools to model particle accelerators and beam transport lines in the MATLAB environment. At SSRL, it has become the modeling code of choice for the ongoing design and future operation of the SPEAR 3 synchrotron light source. AT was designed to take advantage of power and simplicity of MATLAB--commercially developed environment for technical computing and visualization. Many examples in this paper illustrate the advantages of the AT approach and contrast it with existing accelerator code frameworks

  9. APT accelerator technology

    International Nuclear Information System (INIS)

    Schneider, J. David

    1996-01-01

    The proposed accelerator production of tritium (APT) project requires an accelerator that provides a cw proton beam of 100 m A at 1300 MeV. Since the majority of the technical risk of a high-current cw (continuous-wave, 100% DF) accelerator resides in the low-energy section, Los Alamos is building a 20 MeV duplicate of the accelerator front end to confirm design codes, beam performance, and demonstrate operational reliability. We report on design details of this low-energy demonstration accelerator (LEDA) and discuss the integrated design of the full accelerator for the APT plant. LEDA's proton injector is under test and has produced more than 130 mA at 75 keV. Fabrication is proceeding on a 6.7- MeV, 8-meter-long RFQ, and detailed design is underway on coupled-cavity drift-tube linac (CCDTL) structures. In addition, detailed design and technology experiments are underway on medium-beta superconducting cavities to assess the feasibility of replacing the conventional (room-temperature copper) high-energy linac with a linac made of niobium superconducting RF cavities. (author)

  10. Stabilization of ion source operation for the ''EG-2.5'' electrostatic accelerator

    International Nuclear Information System (INIS)

    Nikitin, V.A.; Yakushev, V.P.

    1980-01-01

    A system for stabilization of operating conditions of an electrostatic accelerator ion source is described. The system is the first stage of stabilizing the ion current on a target. The current of the beam escaping from a source is equal to the difference between the currents in the source anode and cathode circuits. In the anode circuit the current is stabilized by changing the HF-generator anode voltage, and the cathode current is stabilized by a special automatic device. This ensures the constancy of the current for a beam which escapes from the source and thus increases the stability of ion currents on a target. The range of current control in the source anode circuit constitutes 15-110 μA, current oscillations do not exceed 0.5% during two hours [ru

  11. KEK digital accelerator

    Directory of Open Access Journals (Sweden)

    T. Iwashita

    2011-07-01

    Full Text Available The High Energy Accelerator Research Organization KEK digital accelerator (KEK-DA is a renovation of the KEK 500 MeV booster proton synchrotron, which was shut down in 2006. The existing 40 MeV drift tube linac and rf cavities have been replaced by an electron cyclotron resonance (ECR ion source embedded in a 200 kV high-voltage terminal and induction acceleration cells, respectively. A DA is, in principle, capable of accelerating any species of ion in all possible charge states. The KEK-DA is characterized by specific accelerator components such as a permanent magnet X-band ECR ion source, a low-energy transport line, an electrostatic injection kicker, an extraction septum magnet operated in air, combined-function main magnets, and an induction acceleration system. The induction acceleration method, integrating modern pulse power technology and state-of-art digital control, is crucial for the rapid-cycle KEK-DA. The key issues of beam dynamics associated with low-energy injection of heavy ions are beam loss caused by electron capture and stripping as results of the interaction with residual gas molecules and the closed orbit distortion resulting from relatively high remanent fields in the bending magnets. Attractive applications of this accelerator in materials and biological sciences are discussed.

  12. Accelerators for research and applications

    International Nuclear Information System (INIS)

    Alonso, J.R.

    1990-06-01

    The newest particle accelerators are almost always built for extending the frontiers of research, at the cutting edge of science and technology. Once these machines are operating and these technologies mature, new applications are always found, many of which touch our lives in profound ways. The evolution of accelerator technologies will be discussed, with descriptions of accelerator types and characteristics. The wide range of applications of accelerators will be discussed, in fields such as nuclear science, medicine, astrophysics and space-sciences, power generation, airport security, materials processing and microcircuit fabrication. 13 figs

  13. Intense pulsed neutron source accelerator status

    International Nuclear Information System (INIS)

    Potts, C.W.; Brumwell, F.R.; Stipp, V.F.

    1983-01-01

    The Intense Pulsed Neutron Source (IPNS) facility has been in operation since November 1, 1981. From that date through August 1, 1983, the accelerator system was scheduled for 7191 hours of operation. During this period, 627 million pulses totaling about 1.1 x 10 21 protons were delivered to the spallation target. The accelerator has exceeded goals set in 1981 by averaging 8.65 μA over this two year period. This average beam current, while modest by the standards of proposed machines, makes the IPNS synchrotron (Rapid Cycling Synchrotron [RCS]) the highest intensity proton synchrotron in the world today. Detailed data on accelerator operation are presented. Weekly average currents of 12 μA have been achieved along with peaks of 13.9 μA. A great deal has been learned about the required operating constraints during high beam current operation. It should be possible to increase the average beam current during this next year to 12 μA while observing these restraints. Improvement plans have been formulated to increase the beam current to 16 μA over the next three years

  14. Accelerated aging tests on ENEA-ASE solar coating for receiver tube suitable to operate up to 550 °C

    Science.gov (United States)

    Antonaia, A.; D'Angelo, A.; Esposito, S.; Addonizio, M. L.; Castaldo, A.; Ferrara, M.; Guglielmo, A.; Maccari, A.

    2016-05-01

    A patented solar coating for evacuated receiver, based on innovative graded WN-AlN cermet layer, has been optically designed and optimized to operate at high temperature with high performance and high thermal stability. This solar coating, being designed to operate in solar field with molten salt as heat transfer fluid, has to be thermally stable up to the maximum temperature of 550 °C. With the aim of determining degradation behaviour and lifetime prediction of the solar coating, we chose to monitor the variation of the solar absorptance αs after each thermal annealing cycle carried out at accelerated temperatures under vacuum. This prediction method was coupled with a preliminary Differential Thermal Analysis (DTA) in order to give evidence for any chemical-physical coating modification in the temperature range of interest before performing accelerated aging tests. In the accelerated aging tests we assumed that the temperature dependence of the degradation processes could be described by Arrhenius behaviour and we hypothesized that a linear correlation occurs between optical parameter variation rate (specifically, Δαs/Δt) and degradation process rate. Starting from Δαs/Δt values evaluated at 650 and 690 °C, Arrhenius plot gave an activation energy of 325 kJ mol-1 for the degradation phenomenon, where the prediction on the coating degradation gave a solar absorptance decrease of only 1.65 % after 25 years at 550 °C. This very low αs decrease gave evidence for an excellent stability of our solar coating, also when employed at the maximum temperature (550 °C) of a solar field operating with molten salt as heat transfer fluid.

  15. Operational problems with radiation survey meters - The University and Accelerator perspectives

    International Nuclear Information System (INIS)

    McCall, R.C.

    1984-06-01

    This article describes problems encountered with commercial survey meters. The desired qualities of such instruments for use around accelerators are listed. Attempts to meet the accelerator monitoring needs by modifying commercial instruments and by in-house research and development are described

  16. ION INJECTION AT QUASI-PARALLEL SHOCKS SEEN BY THE CLUSTER SPACECRAFT

    International Nuclear Information System (INIS)

    Johlander, A.; Vaivads, A.; Khotyaintsev, Yu. V.; Retinò, A.; Dandouras, I.

    2016-01-01

    Collisionless shocks in space plasma are known to be capable of accelerating ions to very high energies through diffusive shock acceleration (DSA). This process requires an injection of suprathermal ions, but the mechanisms producing such a suprathermal ion seed population are still not fully understood. We study acceleration of solar wind ions resulting from reflection off short large-amplitude magnetic structures (SLAMSs) in the quasi-parallel bow shock of Earth using in situ data from the four Cluster spacecraft. Nearly specularly reflected solar wind ions are observed just upstream of a SLAMS. The reflected ions are undergoing shock drift acceleration (SDA) and obtain energies higher than the solar wind energy upstream of the SLAMS. Our test particle simulations show that solar wind ions with lower energy are more likely to be reflected off the SLAMS, while high-energy ions pass through the SLAMS, which is consistent with the observations. The process of SDA at SLAMSs can provide an effective way of accelerating solar wind ions to suprathermal energies. Therefore, this could be a mechanism of ion injection into DSA in astrophysical plasmas

  17. Installation of the Ion Accelerator for the Surface Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyeok-Jung; Kim, Han-Sung; Chung, Bo-Hyun; Ahn, Tae-Sung; Kim, Dae-Il; Kim, Cho-Rong; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this paper, an introduction to the accelerator, an installation status at KOMAC and the operation plan of the accelerator are discussed. A pelletron, which has been used over 25 years at KIGAM, is moved and installed at KOMAC in order to supply a qualified service to ion beam users. The system will be installed in September and component tests will be carried. The operation of the system starts in 2016 after it gets operation license from Nuclear Safety and Security Commission. Korea Multi-purpose Accelerator Complex (KOMAC) is operating several ion beam accelerators to provide various ion beams to users. Those are a 100 MeV proton linear accelerator, a 220 keV ion implanter for gaseous ion beams, a 150 keV metal ion implanter and a 20 keV high-current ion implanter. All of those are the machine for user service and it is important to qualify the results of the irradiation conditions for user service. For this reason, an electrostatic tandem accelerator, which has been operating over 25 years at Korea Institute of Geoscience and Mineral Resources (KIGAM), is moved to KOMAC in order to supply the qualified and quantified data on the irradiation species.

  18. VEDs for charged particle accelerators: Indian scenario

    International Nuclear Information System (INIS)

    Bhandari, R.K.

    2012-01-01

    In the initial times after their invention, the charged particle accelerators have, primarily, been used for fundamental studies on nuclei and atoms. From the first modern accelerator, the cathode ray tube, used by J.J. Thomson for the discovery of electron, very recently the gigantic 27 km circumference Large Hadron Collider (LHC) is operational in the search of Higg's boson and related physics issues. Particle accelerators have emerged as powerful microscopes for investigating the finest details of cells, genes, molecules, atoms, protons, neutrons, muons, electrons, quarks and, possibly, still undiscovered even more fundamental constituents of the universe, such as dark matter and dark energy. Several noble prize winning discoveries have been made using accelerators. Accelerators are now being used in a wide area of industrial and medical applications. They are used for the production of radioisotopes for medical imaging, cancer therapy, food sterilization, treatment of waste water, sterilization of medical equipment, material modification, mass spectroscopy, cargo scanning, fabrication of semiconductors etc. Ongoing effort towards the development of accelerators with megawatt beam power is showing hope for a cleaner source of nuclear energy and treatment of nuclear waste. Several tens of thousands of accelerators are presently operational in the world for basic research and applications. Development of new accelerators has several times been driven by new technologies and materials and sometimes they have driven the technological developments towards cutting edge. Some examples are ultra-high vacuum in large volumes, superfluid helium in cryogenics, cryocoolers, superconducting magnets and RF cavities, high power vacuum electronic devices, global control systems, superfast computing and communication networks, giant data storage/processing systems etc. India has been pursuing a fairly robust programme of accelerator development at various institutions. It

  19. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960's to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore's Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail

  20. Linear induction accelerators

    International Nuclear Information System (INIS)

    Briggs, R.J.

    1986-06-01

    The development of linear induction accelerators has been motivated by applications requiring high-pulsed currents of charged particles at voltages exceeding the capability of single-stage, diode-type accelerators and at currents too high for rf accelerators. In principle, one can accelerate charged particles to arbitrarily high voltages using a multi-stage induction machine, but the 50-MeV, 10-kA Advanced Test Accelerator (ATA) at LLNL is the highest voltage machine in existence at this time. The advent of magnetic pulse power systems makes sustained operation at high-repetition rates practical, and this capability for high-average power is very likely to open up many new applications of induction machines in the future. This paper surveys the US induction linac technology with primary emphasis on electron machines. A simplified description of how induction machines couple energy to the electron beam is given, to illustrate many of the general issues that bound the design space of induction linacs

  1. Heavy ion acceleration at the AGS

    International Nuclear Information System (INIS)

    Lee, Y.Y.

    1989-01-01

    The Brookhaven AGS is alternating gradient synchrotron, 807 meters in circumference, which was originally designed for only protons. Using the 15 MV Brookhaven Tandem Van de Graaff as an injector, the AGS started to accelerate heavy ions of mass lighter than sulfur. Because of the relatively poor vacuum (∼10 -8 Torr), the AGS is not able to accelerate heavier ions which could not be fully stripped of electrons at the Tandem energy. When the AGS Booster, which is under construction, is completed the operation will be extended to all species of heavy ions including gold and uranium. Because ultra-high vacuum (∼10 -11 Torr) is planned, the Booster can accelerate partially stripped elements. The operational experience, the parameters, and scheme of heavy ion acceleration will be presented in detail from injection to extraction, as well as future injection into the new Relativistic Heavy Ion Collider (RHIC). A future plan to improve intensity of the accelerator will also be presented. 5 figs., 4 tabs

  2. The continuous electron beam accelerator facility

    International Nuclear Information System (INIS)

    Grunder, H.A.

    1989-01-01

    Tunnel construction and accelerator component development, assembly, and testing are under way at the Continuous Electron Beam Accelerator Facility. CEBAF's 4-GeV, 200-μA superconducting recirculating accelerator will provide cw beam to simultaneous experiments in three end stations for studies of the nuclear many-body system, its quark substructure, and the strong and electroweak interactions governing this form of matter. Prototype accelerating cavities, assembled in cryostats and tested on site, continue to exceed performance specifications. An on-site liquid helium capability supports cryostat development and cavity testing. Major elements of the accelerator instrumentation and control hardware and software are in use in cryogenics, rf, and injector tests. Prototype rf systems have been operated and prototype klystrons have been ordered. The initial, 100-keV, room-temperature region of the 45-MeV injector is operational and meets specifications. CEBAF's end stations have been conceptually designed; experimental equipment conceptual designs will be completed in 1989. 2 refs., 5 figs., 2 tabs

  3. To the problem of software development for two-sided communication system between an operator and computers in the automatic control system of elementary particle accelerators

    International Nuclear Information System (INIS)

    Asyaev, Yu.V.; Burtsev, V.L.; Makarov, V.V.; Nikitin, V.D.; Solov'ev, G.N.

    1975-01-01

    Principles, composition and basic characteristics of the software for a system of operators communication with minicomputers within the automatic accelerator control system are described. It is indicated that the external language of communication proposed in the system should meet the requirements for a provision of dialogue between the operator and the minicomputer operating in the real-time mode with an accelerator. There is a set of standard procedures allowing the operator to interact with the system in a sufficiently complete and flexible manner. These standard procedures are provided in the external operator's language in the form of a set of the control statements. The basic programs of the software system for communication are MONITOR, INTERPRETER and DRIVER programs. The MONITOR program algorithm employs the following principles - service of the input/output requests in the system is made on the relative priority basis: the maximum priority is assigned to operator's requests, the requests of the dispatcher and application programs are at a lower priority level

  4. The Volterra's integral equation theory for accelerator single-freedom nonlinear components

    International Nuclear Information System (INIS)

    Wang Sheng; Xie Xi

    1996-01-01

    The Volterra's integral equation equivalent to the dynamic equation of accelerator single-freedom nonlinear components is given, starting from which the transport operator of accelerator single-freedom nonlinear components and its inverse transport operator are obtained. Therefore, another algorithm for the expert system of the beam transport operator of accelerator single-freedom nonlinear components is developed

  5. TIARA electrostatic accelerator facility

    International Nuclear Information System (INIS)

    Tajima, Satoshi; Takada, Isao; Mizuhashi, Kiyoshi; Uno, Sadanori; Ohkoshi, Kiyonori; Nakajima, Yoshinori; Saitoh, Yuichi; Ishii, Yasuyuki; Kamiya, Tomihiro

    1996-07-01

    In order to promote the Advanced Radiation Technology Project, Japan Atomic Energy Research Institute constructed TIARA facility composed of four ion accelerators at Takasaki Radiation Chemistry Research Establishment for the period from 1988 to 1993. A 3MV tandem accelerator and an AVF cycrotron were completed in 1991 as the first phase of the construction, and a 3MV single-ended accelerator and a 400kV ion implanter were completed in 1993 as the second phase. Three electrostatic accelerators, the tandem, the single-ended and the implanter, were installed in the Multiple-beam facility of TIARA and have been operated for various experiments with using single, dual and triple beams without any serious trouble. This report describes the constructive works, machine performances, control systems, safety systems and accessory equipments of the electrostatic accelerators. (author)

  6. Proceedings of CAS - CERN Accelerator School: Course on Superconductivity for Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, R [European Organization for Nuclear Research, Geneva (Switzerland)

    2014-07-01

    These proceedings collate lectures given at the twenty-seventh specialized course organised by the CERN Accelerator School (CAS). The course was held at the Ettore Majorana Foundation and Centre for Scientific Culture (EMFCSC) in Erice, Italy, from 24 April to 4 May 2013. Following recapitulation lectures on basic accelerator physics and superconductivity, the course covered topics related to the design, production and operation of superconducting RF systems and superconducting magnets for accelerators. The participants pursued one of six case studies in order to get ’hands-on’ experience of the issues connected with the design of superconducting systems. A series of topical seminars completed the programme.

  7. The Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.

    1992-01-01

    The Brookhaven National Laboratory Accelerator Test Facility comprises a 50 MeV traveling wave electron linear accelerator utilizing a high gradient, photo-excited, raidofrequency electron gun as an injector and an experimental area for study of new acceleration methods or advanced radiation sources using free electron lasers. Early operation of the linear accelerator system including calculated and measured beam parameters are presented together with the experimental program for accelerator physics and free electron laser studies

  8. properties of the SN - equivalent integral transport operator in slab geometry and the iterative acceleration of neutron transport methods

    International Nuclear Information System (INIS)

    Massimiliano, Rosa; Azmy, Y.Y.; Morel, J.E.

    2005-01-01

    The general expressions for the matrix elements of the discrete Sn-equivalent integral transport operator have been derived in slab geometry. Their asymptotic behavior has been investigated both for a homogeneous slab and for a heterogeneous slab characterized by a periodic material discontinuity wherein each optically thick cell is surrounded by two optically thin cells in a repeating pattern. In the case of a homogeneous slab, the asymptotic analysis conducted in a diffusive limit obtained as the thick limit of computational cell size for a highly scattering medium, has shown that the discretized integral transport operator is approximated by a sparse matrix characterized by a tri-diagonal diffusion-like coupling stencil. Also, the tri-diagonal matrix structure, characteristic of the diffusion coupling stencil, is approached at a fast exponential rate. In the case of periodically heterogeneous slab configurations, the asymptotic behavior investigated is that in which the cells' optical thicknesses are pushed apart, i.e. the thick is made thicker while the thin is made thinner at a prescribed rate. It has been shown that in this limit the discretized integral transport operator is approximated by a penta-diagonal structure. Notwithstanding, the discrete operator is amenable to algebraic transformations leading to a matrix representation still asymptotically approaching a tri-diagonal structure at a fast exponential rate. The existence of a low order tri-diagonal approximation to the full discrete integral transport operator in the case of a periodically heterogeneous slab might provide a basic understanding of the superior convergence properties of diffusion-based acceleration schemes observed in slab geometry, even in the presence of sharp material discontinuities. The obtained results also suggest that a sparse approximation to the S n -equivalent integral transport operator might itself be used as the low-order operator in an acceleration scheme for the

  9. Parametric study of emerging high power accelerator applications using Accelerator Systems Model (ASM)

    International Nuclear Information System (INIS)

    Berwald, D.H.; Mendelsohn, S.S.; Myers, T.J.; Paulson, C.C.; Peacock, M.A.; Piaszczyk, CM.; Rathke, J.W.; Piechowiak, E.M.

    1996-01-01

    Emerging applications for high power rf linacs include fusion materials testing, generation of intense spallation neutrons for neutron physics and materials studies, production of nuclear materials and destruction of nuclear waste. Each requires the selection of an optimal configuration and operating parameters for its accelerator, rf power system and other supporting subsystems. Because of the high cost associated with these facilities, economic considerations become paramount, dictating a full evaluation of the electrical and rf performance, system reliability/availability, and capital, operating, and life cycle costs. The Accelerator Systems Model (ASM), expanded and modified by Northrop Grumman during 1993-96, provides a unique capability for detailed layout and evaluation of a wide variety of normal and superconducting accelerator and rf power configurations. This paper will discuss the current capabilities of ASM, including the available models and data base, and types of trade studies that can be performed for the above applications. (author)

  10. Analysis and performance of adjacent-cell preconditioners for accelerating multidimensional transport calculations

    International Nuclear Information System (INIS)

    Azmy, Y.Y.

    1996-01-01

    The formal development of the Adjacent-cell Preconditioner (AP) and its implementation in the TORT code are briefly reviewed. Based on earlier experience with diffusion type acceleration, and excellent results in slab geometry the reciprocal averaging formula is used to mix the preconditioner elements across material and mesh discontinuities. Numerical testing of the method employing the Burre Suite of Test Problems (BSTeP), a collection of 144 cases covering a wide range in parameter space, using AP, Partial Current Rebalance (PCR), and TWODANT's Diffusion Synthetic Acceleration (DSA) is presented. While AP outperforms the other two methods for the majority of the cases included in BSTeP it consumes many more iterations than can be explained by spectral analysis of the homogeneous model problem in cases with sharp material discontinuity. In order to verify this undesirable behavior and explore potential remedies a model problem, the Periodic Horizontal Interface (PHI), is developed that permits discontinuity of nuclear properties and cell height across the interface. Fourier mode decomposition is applied to AP with the reciprocal averaging mixing formula for the PHI configuration and shown to possess a spectral radius that approaches unity as the material discontinuity gets larger. The question of whether an unconditionally stable AP exists for PHI is tackled and preliminary indications are negative. Novel preconditioners that have nontraditional cell-coupling schemes that remain stable in these regimes may have to be sought

  11. Plasma particle accelerators

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1988-01-01

    The Superconducting Supercollider (SSC) will require an 87-kilometer accelerator ring to boost particles to 40 TeV. The SSC's size is due in part to the fact that its operating principle is the same one that has dominated accelerator design for 50 years: it guides particles by means of magnetic fields and propels them by strong electric fields. If one were to build an equally powerful but smaller accelerator, one would need to increase the strength of the guiding and propelling fields. Actually, however, conventional technology may not be able to provide significant increases in field strength. There are two reasons. First, the forces from magnetic fields are becoming greater than the structural forces that hold a magnetic material together; the magnets that produce these fields would themselves be torn apart. Second, the energy from electric fields is reaching the energies that bind electrons to atoms; it would tear electrons from nuclei in the accelerator's support structures. It is the electric field problem that plasma accelerators can overcome. Plasma particle accelerators are based on the principle that particles can be accelerated by the electric fields generated within a plasma. Because the plasma has already been ionized, plasma particle accelerators are not susceptible to electron dissociation. They can in theory sustain accelerating fields thousands of times stronger that conventional technologies. So far two methods for creating plasma waves for accelerators have been proposed and tested: the wakefield and the beat wave. Although promising electric fields have been produced, more research is necessary to determine whether plasma particle accelerators can compete with the existing accelerators. 7 figs

  12. Accelerators in industrial electron beam processing

    International Nuclear Information System (INIS)

    Becker, R.C.

    1984-01-01

    High power electron beam accelerators are being used for a variety of industrial processes. Such machines can process a wide range of products at very high thruput rates and at very low unit processing costs. These industrial accelerators are now capable of producing up to 200 kW of electron beam power at 4.0 MV and 100 kW at 5.0 MV. At this writing, even larger units are contemplated. The reliability of these high power devices also makes it feasible to consider bremsstrahlung (x-ray) processing as well. In addition to the advance of accelerator technology, microprocessor control systems now provide the capability to coordinate all the operations of the irradiation facility, including the accelerator, the material handling system, the personnel safety system and various auxiliary services. Facility designs can be adapted to many different industrial processes, including use of the dual purpose electron/x-ray accelerator, to ensure satisfactory product treatment with good dose uniformity, high energy efficiency and operational safety and simplicity. In addition, equipment manufacturers like RDI are looking beyond their conventional DC accelerator technology; looking at high power 10-12 MeV linear accelerators with power levels up to 25 kW or more. These high power linear accelerators could be the ideal processing tool for many sterilization and food irradiation applications. (author)

  13. RF linear accelerators for medical and industrial applications

    CERN Document Server

    Hanna, Samy

    2012-01-01

    This unique resource offers you a clear overview of medical and industrial accelerators. Using minimal mathematics, this book focuses on offering thorough explanations of basic concepts surrounding the operation of accelerators. you find well illustrated discussions designed to help you use accelerator-based systems in a safer, more productive, and more reliable manner.This practical book details the manufacturing process for producing accelerators for medical and industrial applications. You become knowledgeable about the commonly encountered real-world manufacturing issues and potential sources of defects which help you avoid costly production problems. From principles of operation and the role of accelerators in cancer radiation therapy, to manufacturing techniques and future trends in accelerator design and applications, this easy-to-comprehend volume quickly brings you up-to-speed with the critical concepts you need to understand for your work in the field.

  14. Overview of SSC accelerator requirements

    International Nuclear Information System (INIS)

    Dugan, G.

    1992-03-01

    This paper will present a general overview of the requirements of the Superconducting Super Collider (SSC) accelerators. Each accelerator in the injector chain will be discussed separately, followed by a discussion of the collider itself. In conclusion, the top level requirements of the overall accelerator system will be presented. For each accelerator, the primary operating parameters will be presented in tabular form. A brief narrative discussion of the principal technical features of each machine will be given. Finally, the principal technical design challenges for the machine will be noted, together with the currently planned solution to these challenges

  15. Cavity digital control testing system by Simulink step operation method for TESLA linear accelerator and free electron laser

    Science.gov (United States)

    Czarski, Tomasz; Romaniuk, Ryszard S.; Pozniak, Krzysztof T.; Simrock, Stefan

    2004-07-01

    The cavity control system for the TESLA -- TeV-Energy Superconducting Linear Accelerator project is initially introduced in this paper. The FPGA -- Field Programmable Gate Array technology has been implemented for digital controller stabilizing cavity field gradient. The cavity SIMULINK model has been applied to test the hardware controller. The step operation method has been developed for testing the FPGA device coupled to the SIMULINK model of the analog real plant. The FPGA signal processing has been verified according to the required algorithm of the reference MATLAB controller. Some experimental results have been presented for different cavity operational conditions.

  16. Theory of factors limiting high gradient operation of warm accelerating structures

    Energy Technology Data Exchange (ETDEWEB)

    Nusinovich, Gregory S. [Univ. of Maryland, College Park, MD (United States)

    2014-07-22

    This report consists of two parts. In the first part we describe a study of the heating of microprotrusions on surfaces of accelerating structures. This ;process is believed to lead to breakdown in these structures. Our study revealed that for current accelerator parameters melting should not occur due to space charge limitations of the current emitted by a protrusion. The second part describes a novel concept to develop THz range sources based on harmonic cyclotron masers for driving future colliders. This work was stimulated by a recent request of SLAC to develop high power, high-efficiency sources of sub-THz radiation for future high-gradient accelerators.

  17. IFMIF accelerator conceptual design activities

    International Nuclear Information System (INIS)

    Jameson, R.A.; Lagniel, J.M.; Sugimoto, M.; Kein, H.; Piaszczyk, C.; Tiplyakov, V.

    1998-01-01

    A Conceptual Design Evaluation (CDE) for the International Fusion Materials Irradiation Facility (IFMIF) began in 1997 and will be completed in 1998, as an international program of the IEA involving the European Community, Japan, Russia and the United States. The IFMIF accelerator system, comprising two 125 mA, 40 MeV deuterium accelerators operating at 175 MHz, is a key element of the IFMIF facility. The objectives and accomplishments of the CDE accelerator studies are outlined

  18. Accelerators in the 1970s

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1980-01-15

    As usual, the advances in our understanding of the nature of matter firing the past decade have leaned heavily on the availability of high energy accelerators which have both revealed new phenomena and enabled theories to be exposed to experiment. There have been many advances in technique, many new approaches, many new ideas on accelerator applications and many splendid new machines brought into operation. We pick out three themes to characterize how accelerators have progressed in ten years.

  19. Dummy accelerating tube as a matching lens for 14UD Pelletron Accelerator, BARC-TIFR, Mumbai

    International Nuclear Information System (INIS)

    Surendran, P.; Nair, J.P.; Bhagwat, P.V.

    2003-01-01

    14UD Pelletron Accelerator Facility has been operational since 1989. The potential grading in the accelerator column and tube is achieved by corona points. At present column and tube corona points are replaced by resistance. The resistance per module in the column and tube are 36 GΩ and 33 GΩ respectively

  20. Choice of initial operating parameters for high average current linear accelerators

    International Nuclear Information System (INIS)

    Batchelor, K.

    1976-01-01

    In designing an accelerator for high currents it is evident that beam losses in the machine must be minimized, which implies well matched beams, and that adequate acceptance under severe space charge conditions must be met. This paper investigates the input parameters to an Alvarez type drift-tube accelerator resulting from such factors

  1. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1997-01-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at Lawrence Livermore National Laboratory (LLNL) from the early 1960s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400-ns pulses. The Advanced Test Accelerator (ATA) built at Livermore close-quote s Site 300 produced 10,000-Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and Lawrence Berkeley National Laboratory (LBNL). This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high-current, short-pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail. copyright 1997 American Institute of Physics

  2. Safety guidance and inspection program for particle accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Whey [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Lee, Hee Seock; Yeo, In Whan [Pohang Accelerator Laboratory, Pohang (Korea, Republic of)] (and others)

    2001-03-15

    The inspection program and the safety guidance were developed to enhance the radiation protection for the use of particle accelerators. First the classification of particle accelerators was conducted to develop the safety inspection protocol efficiently. The status of particle accelerators which were operated at the inside and outside of the country, and their safety programs were surveyed. The characteristics of radiation production was researched for each type of particle accelerators. Two research teams were launched for industrial and research accelerators and for medical accelerators, respectively. In each stages of a design, a fabrication, an installation, a commissioning, and normal operation of accelerators, those safety inspection protocols were developed. Because all protocols resulted from employing safety experts, doing the questionnaire, and direct facility surveys, it can be applicable to present safety problem directly. The detail improvement concepts were proposed to revise the domestic safety rule. This results might also be useful as a practical guidance for the radiation safety officer of an accelerator facility, and as the detail standard for the governmental inspection authorities.

  3. Resolving beam transport problems in electrostatic accelerators

    International Nuclear Information System (INIS)

    Larson, J.D.

    1977-01-01

    This paper reviews problem areas in beam transmission which are frequently encountered during the design, operation and upgrading of electrostatic accelerators. Examples are provided of analytic procedures that clarify accelerator ion optics and lead to more effective beam transport. Suggestions are made for evaluating accelerator design with the goal of improved performance

  4. Performance of the intense pulsed neutron source accelerator system

    International Nuclear Information System (INIS)

    Potts, C.; Brumwell, F.; Rauchas, A.; Stipp, V.; Volk, G.

    1983-01-01

    The Intense Pulsed Neutron Source (IPNS) facility has now been operating in a routine way for outside users since November 1, 1981. From that date through December of 1982, the accelerator system was scheduled for neutron science for 4500 hours. During this time the accelerator achieved its short-term goals by delivering about 380,000,000 pulses of beam totaling over 6 x 10 20 protons. The changes in equipment and operating practices that evolved during this period of intense running are described. The intensity related instability threshold was increased by a factor of two and the accelerator beam current has been ion source limited. Plans to increase the accelerator intensity are also described. Initial operating results with a new H - ion source are discussed

  5. Characteristics of particle beam acceleration on KUMS tandem electrostatic accelerator 5SDH-2

    OpenAIRE

    谷池, 晃; 古山, 雄一; 北村, 晃

    2006-01-01

    The KUMS tandem electrostatic accelerator, 5SDH-2, was installed in 1996. Ten years have passed since it installed and we obtain some data for accelerator operations. We report the particle beam characteristics such as relation between beam species and switcher magnet current, and dependence of ion charge fraction on stripper gas thickness. We also try to generate nitrogen ion beams, and low energy ion beams.

  6. Community Petascale Project for Accelerator Science and Simulation: Advancing Computational Science for Future Accelerators and Accelerator Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Spentzouris, P.; /Fermilab; Cary, J.; /Tech-X, Boulder; McInnes, L.C.; /Argonne; Mori, W.; /UCLA; Ng, C.; /SLAC; Ng, E.; Ryne, R.; /LBL, Berkeley

    2011-11-14

    for software development and applications accounts for the natural domain areas (beam dynamics, electromagnetics, and advanced acceleration), and all areas depend on the enabling technologies activities, such as solvers and component technology, to deliver the desired performance and integrated simulation environment. The ComPASS applications focus on computationally challenging problems important for design or performance optimization to all major HEP, NP, and BES accelerator facilities. With the cost and complexity of particle accelerators rising, the use of computation to optimize their designs and find improved operating regimes becomes essential, potentially leading to significant cost savings with modest investment.

  7. Analysis of fallopian tube recanalization in 37 cases with Foley catheter infusion under pressure through DSA

    International Nuclear Information System (INIS)

    Huang Qiuli; Song Kankan; Wu Anle; Shu Jing

    2000-01-01

    Objective: To investigate the safe, effective, simple and direct method in the re-canalization of fallopian tubal obstruction. Methods: Fallopian tubal obstructive infertility in 37 cases were re-canalized with Foley catheter under pressure infusion through DSA, including primary infertility in 17 cases and secondary infertility in 20 cases. The average infertility term was 4 years. Results: In the 37 cases, 18 cases were treated once, twice in 16 cases, and thrice in 3 cases. The oviduct recanalization rate was 95% (35/37) with one failure and another unsatisfactory. After several times of recanalization in 19 cases, the pelvic cavity adhesion were reduced in 15 cases (79%), no change in 3 cases (16%), and aggravated in one case (5%). Conclusions: This method is simple, cheap, safety, effective and low in X-ray exposure. The authors insist on the pelvic cavity adhesion is still the chief cause of infertility after recanalization and still need other kind of treatment

  8. AXEL–2014: Introduction to Particle Accelerators

    CERN Multimedia

    2014-01-01

    AXEL-2014 is a series of courses on particle accelerators, given at CERN within the framework of the 2014 Technical Training Program. As part of the BE Department’s Operation Group Shutdown Lecture series, the general accelerator physics module has been organised since 2003 as a joint venture between the BE Department and Technical Training, and is open to the wider CERN community.   The AXEL-2014 course series is designed for technicians who are operating an accelerator or whose work is closely linked to accelerators, but it is also open to technicians, engineers, and physicists interested in this field. The course does not require any prior knowledge of accelerators. However, some basic knowledge of trigonometry, matrices and differential equations, and some basic knowledge of magnetism would be an advantage. The series will be composed of 10 modules (Monday 24 March 2014 – Fri 28 March 2014, from 9 a.m. to 10:15 a.m. and from 10:45 a.m. to 12 noon), and will be given in En...

  9. Department of Accelerator Physics and Technology: Overview

    International Nuclear Information System (INIS)

    Pachan, M.

    1999-01-01

    Full text: As presented at the overview seminar held on December 98, the activities of the Department were shared among several directions of accelerator applications, as well as research and development works on new accelerator techniques and technologies. In the group of proton and ion accelerators, two main tasks were advanced. The first was a further step in the optimization of operational parameters of multicusp ion-source, prepared for axial injection system in C-30 cyclotron. Another one is the participation in important modifications of r.f. acceleration system in heavy-ion accelerator C-200 of Warsaw University. In the broad field of electron accelerators our main attention was directed at medical applications. Most important of them was the designing and construction of a full scale technological model of a high-gradient accelerating structure for low-energy radiotherapy unit CO-LINE 1000. Microwave measurements, and tuning were accomplished, and the technical documentation for construction of radiation unit completed. This work was supported by the State Committee for Scientific Research. Preparatory work was continued to undertake in the year 1999 the design of two new medical accelerators. First is a new generation radiotherapy unit, with 15 MeV electron beam and two selected energies of X-ray photons. This accelerator should in future replace the existing Neptun 10 MeV units. The work will be executed in the frame of the Project-Ordered commissioned by the State Committee for Scientific Research. The next type of accelerators in preparation is the mobile, self-shielded electron-beam unit for inter operative irradiation. The specification of parameters was completed and study of possible solutions advanced. The programme of medical accelerator development is critically dependent on the existence of a metrological and experimental basis. Therefore the building of a former proton linear accelerator was adopted to the new function as electron accelerators

  10. Channel-accelerating gap interaction and beam acceleration and transport experiments with the recirculating linear accelerator (RLA)

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Smith, D.L.; Poukey, J.W.; Wagner, J.S.; Bennett, L.F.; Olson, W.R.; Turman, B.N.; Prestwich, K.R.; Wells, J.; Struve, K.

    1992-01-01

    The lifetime of the Ion Focusing Regime (IFR) channel following the pulsing of the post-accelerating gaps is critical for open-ended low energy devices. It dictates the number of allowable beam recirculations through the gaps. In the case of a closed racetrack configuration, it is significant but not as critical, since the presence of the electron beam focuses the ions and lengthens the lifetime of the ion channel. The authors have experimentally established that pulsing an accelerating gap perturbs the IFR channel. However for the parameters studied, the lifetime is long enough to allow at least four beam recirculations in a spiral device. In addition transparent grids of cusp fields positioned upstream and downstream from the gaps prevent them from perturbing the IFR channel. Experiments were performed with and without injected electron beams. For the experiments investigating the IFR channel interaction with the accelerating gap, the injector was removed and the beam line was extended downstream and upstream from the accelerating cavity. Only the first straight section of the RLA with one accelerating cavity (ET-2) was utilized. The acceleration and transport experiments were performed utilizing two injectors: first the low energy 1.3-MV Isolated Blumlein (IB) injector and most recently the new 4-MV 20-kA injector. Beams of 6--20 kA current were produced and successfully transported and accelerated through the ET-2 post-accelerating gap. For both injectors an apertured non-immersed ion-focused foilless diode was selected among various options. It is the simplest and easiest to operate and can be adjusted to provide variable beam impedance loads to the injector. The transport efficiencies were 90% for the low energy injector and 100% for the new 4-MV injector. The beam Gaussian profile and radius (5 mm) remain the same through acceleration. Experimental results will be presented and compared with numerical simulations

  11. Clearance of materials from accelerator facilities

    Directory of Open Access Journals (Sweden)

    Rokni Sayed H.

    2017-01-01

    Full Text Available A new Technical Standard that supports the clearance of materials and equipment (personal property from U.S. Department of Energy (DOE accelerator facilities has been developed. The Standard focuses on personal property that has the potential to be radiologically impacted by accelerator operations. It addresses material clearance programs and protocols for off-site releases without restriction on use. Common metals with potential volumetric activation are of main interest with technical bases provided in Appendices of the Standard. The clearance protocols in the Standard include three elements: 1 clearance criteria, 2 process knowledge, and 3 measurement methods. This paper presents the technical aspects of the new Standard, discusses operational experience gained in clearance of materials and equipment from several accelerator facilities at SLAC and examples as to how this Standard can be applied to benefit the entirety of the DOE Accelerator Complex.

  12. Virtual accelerator concept, implementation and preliminary test

    International Nuclear Information System (INIS)

    Uriot, D.; Duperrier, R.

    2006-05-01

    A virtual accelerator is the coupling of a simulation code with the control system of a real machine. 3 operating modes are considered. First, the monitoring mode in which any action on the control system has an impact on both real and virtual machines. This mode allows a direct comparison between simulation results and the real behaviour of the accelerator. Secondly, the flight simulation mode, this mode allows the accelerator operators to simulate the effect of any change in the parameters of the control system before transferring them to the real machine. The main advantage of this mode is to allow the assessment of operating procedures before implementing them on the real machine. The third mode is the automatic steering mode in which the simulation code assumes the reins of the control system of the real machine. This mode allows the making of complex and time-consuming adjustment procedures in an automatic way. TraceWin is a simulation code dedicated to the behaviour of charged-particle beams in a linear accelerator. TraceWin is consistent with the EPICS technology on which the control system of most accelerators is based. A virtual accelerator composed of the SILHI injector combined to the TraceWin code via the EPICS environment has showed its efficiency in the automatic steering mode. (A.C.)

  13. Production of neutrons in particle accelerators: a PNRI safety concern

    International Nuclear Information System (INIS)

    Garcia, Corazon M.; Cayabo, Lynette B.; Artificio, Thelma P.; Melendez, Johnylen V.; Piquero, Myrna E.; Parami, Vangeline K.

    2002-09-01

    In the safety assessment made for the first cyclotron facility in the Philippines, that is the cyclotron in the P.E.T. (Positron Emission Tomography) center of the St. Luke's Medical Center, the concern on the production of neutrons associated with the operation of particle accelerators has been identified. This takes into consideration the principles in the operation of particle accelerators and the associated production of neutrons resulting from their operation, the hazards and risks in their operation. The Bureau of Health Devices and Technology (BHDT) of the Department of Health in the Philippines regulates and controls the presently existing six (6) linear accelerators distributed in different hospitals in the country, being classified as x-ray producing devices. From the results of this study, it is evident that the production of neutrons from the operation of accelerators, produces neutrons and that activation due to neutrons can form radioactive materials. The PNRI (Philippine Nuclear Research Institute) being mandated by law to regulate and control any equipment or devices producing or utilizing radioactive materials should take the proper steps to subject all accelerator facilities and devices in the Philippines such as linear accelerators under its regulatory control in the same manner as it did with the first cyclotron in the country. (Author)

  14. EPICS-QT based graphical user interface for accelerator control

    International Nuclear Information System (INIS)

    Basu, A.; Singh, S.K.; Rosily, Sherry; Bhagwat, P.V.

    2016-01-01

    Particle accelerators and many industrial complex systems, require a robust and efficient control for its proper operation to achieve required beam quality, safety of its sub component and all working personnel. This control is executed via a graphical user interface through which an operator interacts with the accelerator to achieve the desired state of the machine and its output. Experimental Physics and Industrial Control System (EPICS) is a widely used control system framework in the field of accelerator control. It acts as a middle layer between field devices and graphic user interface used by the operator. Field devices can also be made EPICS compliant by using EPICS based software in that. On the other hand Qt is a C++ framework which is widely used for creating very professional looking and user friendly graphical component. In Low Energy High Intensity Proton Accelerator (LEHIPA), which is the first stage of the three stage Accelerator Driven System (ADS) program taken by Bhabha Atomic Research Centre (BARC), it is decided that EPICS will be used for controlling the accelerator and Qt will be used for developing the various Graphic User Interface (GUI) for operation and diagnostics. This paper discuss the work carried out to achieve this goal in LEHIPA

  15. Resolving beam transport problems in electrostatic accelerators

    International Nuclear Information System (INIS)

    Larson, J.D.

    1977-01-01

    A review is given of problem areas in beam transmission which are frequently encountered during the design, operation and upgrading of electrostatic accelerators. Examples are provided of analytic procedures that clarify accelerator ion optics and lead to more effective beam transport. Suggestions are made for evaluating accelerator design with the goal of improved performance

  16. Radiation protection in large linear accelerators

    International Nuclear Information System (INIS)

    Oliva, Jose de Jesus Rivero

    2013-01-01

    The electron linear accelerators can be used in industrial applications that require powerful sources of ionizing radiation. They have the important characteristic of not representing a radiation hazard when the accelerators remain electrically disconnected. With the plant in operation, a high reliability defense in depth reduces the risk of radiological accidents to extremely small levels. It is practically impossible that a person could enter into the radiation bunker with the accelerators connected. Aceletron Irradiacao Industrial, located in Rio de Janeiro, offers services of irradiation by means of two powerful electron linear accelerators, with 15 kW power and 10 MeV electron energy. Despite the high level of existing radiation safety, a simplified risk study is underway to identify possible sequences of radiological accidents. The study is based on the combined application of the event and fault trees techniques. Preliminary results confirm that there is a very small risk of entering into the irradiation bunker with the accelerators in operation, but the risk of an operator entering into the bunker during a process interruption and remaining there without notice after the accelerators were restarted may be considerably larger. Based on these results the Company is considering alternatives to reduce the likelihood of human error of this type that could lead to a radiological accident. The paper describes the defense in depth of the irradiation process in Aceletron Irradiacao Industrial, as well as the models and preliminary results of the ongoing risk analysis, including the additional safety measures which are being evaluated. (author)

  17. The Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Hall, E.J.; Marino, S.A.

    1991-05-01

    The Radiological Research Accelerator Facility (RARAF) is based on 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) -- formerly the Radiological Research Laboratory (RRL) -- of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). As such, RARAF is available to all potential users on an equal basis, and scientists outside the CRR are encouraged to submit proposals for experiments at RARAF. The operation of the Van de Graaff is supported by the DOE, but the research projects themselves must be supported separately. Brief summaries of research experiments are included. Accelerator usage is summarized and development activities are discussed. 8 refs., 8 tabs

  18. CAS Accelerator Physics (RF for Accelerators) in Denmark

    CERN Multimedia

    Barbara Strasser

    2010-01-01

    The CERN Accelerator School (CAS) and Aarhus University jointly organised a specialised course on RF for Accelerators, at the Ebeltoft Strand Hotel, Denmark from 8 to 17 June 2010.   Caption The challenging programme focused on the introduction of the underlying theory, the study and the performance of the different components involved in RF systems, the RF gymnastics and RF measurements and diagnostics. This academic part was supplemented with three afternoons dedicated to practical hands-on exercises. The school was very successful, with 100 participants representing 25 nationalities. Feedback from the participants was extremely positive, praising the expertise and enthusiasm of the lecturers, as well as the high standard and excellent quality of their lectures. In addition to the academic programme, the participants were able to visit a small industrial exhibition organised by Aarhus University and take part in a one-day excursion consisting of a visit of the accelerators operated ...

  19. Optimization of negative ion accelerators

    International Nuclear Information System (INIS)

    Pamela, J.

    1991-01-01

    We have started to study negative ion extraction and acceleration systems in view of designing a 1 MeV D - accelerator. This study is being made with a two-Dimensional code that has been specifically developed in our laboratory and validated by comparison to three sets of experimental data. We believe that the criteria for negative ion accelerator design optimization should be: (i) to provide the best optics; (ii) to reduce the power load on the extraction grid; (iii) to allow operation with low electric fields in order to reduce the problem of breakdowns. We show some results of optics calculations performed for two systems that will be operational in the next months: the CEA-JAERI collaboration at Cadarache and the european DRAGON experiment at Culham. Extrapolations to higher energies of 500 to 1100 keV have also been conducted. All results indicate that the overall accelerator length, whatever be the number of gaps, is constrained by space charge effects (Child-Langmuir). We have combined this constraint with high-voltage hold-off empirical laws. As a result, it appears that accelerating 10 mA/cm 2 of D - at 1 MeV with good optics, as required for NET or ITER, is close to the expected limit of high-voltage hold-off

  20. Application of digital subtraction angiography in disease of large cardiac vessel

    Energy Technology Data Exchange (ETDEWEB)

    Arisawa, Jun; Sone, Shusuke; Morimoto, Shizuo; Ikezoe, Junpei; Higashibara, Tokuro; Hanayama, Masayuki

    1983-06-01

    Digital subtraction angiography (DSA) was performed in 31 cases of disease of large cardiac vessel. DSA was useful for the diagnosis of aortic aneurysm and malformation of large vessels, follow-up after A-C bypass operation and Blalock's shunt operation for tetralogy of Fallot and as an adjuvant modality in cardiac catheterization.

  1. Application of digital subtraction angiography in disease of large cardiac vessel

    International Nuclear Information System (INIS)

    Arisawa, Jun; Sone, Shusuke; Morimoto, Shizuo; Ikezoe, Junpei; Higashibara, Tokuro; Hanayama, Masayuki

    1983-01-01

    Digital subtraction angiography (DSA) was performed in 31 cases of disease of large cardiac vessel. DSA was useful for the diagnosis of aortic aneurysm and malformation of large vessels, follow-up after A-C bypass operation and Blalock's shunt operation for tetralogy of Fallot and as an adjuvant modality in cardiac catheterization. (Chiba, N.)

  2. Superconducting linear accelerator cryostat

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Elkonin, B.V.; Sokolowski, J.S.

    1984-01-01

    A large vertical cryostat for a superconducting linear accelerator using quarter wave resonators has been developed. The essential technical details, operational experience and performance are described. (author)

  3. Multi-beam linear accelerator EVT

    Energy Technology Data Exchange (ETDEWEB)

    Teryaev, Vladimir E., E-mail: vladimir_teryaev@mail.ru [Omega-P, Inc., New Haven, CT 06510 (United States); Kazakov, Sergey Yu. [Fermilab, Batavia, IL 60510 (United States); Hirshfield, Jay L. [Omega-P, Inc., New Haven, CT 06510 (United States); Yale University, New Haven, CT 06511 (United States)

    2016-09-01

    A novel electron multi-beam accelerator is presented. The accelerator, short-named EVT (Electron Voltage Transformer) belongs to the class of two-beam accelerators. It combines an RF generator and essentially an accelerator within the same vacuum envelope. Drive beam-lets and an accelerated beam are modulated in RF modulators and then bunches pass into an accelerating structure, comprising uncoupled with each other and inductive tuned cavities, where the energy transfer from the drive beams to the accelerated beam occurs. A phasing of bunches is solved by choice correspond distances between gaps of the adjacent cavities. Preliminary results of numerical simulations and the initial specification of EVT operating in S-band, with a 60 kV gun and generating a 2.7 A, 1.1 MV beam at its output is presented. A relatively high efficiency of 67% and high design average power suggest that EVT can find its use in industrial applications.

  4. Results of LIA-10M accelerator investigations

    CERN Document Server

    Gordeev, V S; Filippov, V O

    2001-01-01

    There are presented basic results of experiments on the LIA-10M accelerator since its putting into operation (1994) till today. There were investigated various modes of accelerator operation and its output characteristics depending on the parameters of injected electron beam,number of connected accelerator modules,time program of inductors switch-in etc. There was obtained a large scope of experimental data that are of interest for LIA-10M accelerator practical use and for the development of new facilities of this type. The investigations that have been performed recently make it possible to considerably (half as much again) increase the output dose parameters of the accelerator as compared to the level achieved before:maximal dose(Si) and dose rate on the output flange constitute 400 Gy and 2.5 centre dot 10 Gy/s, while at a 1 meter distance from the target they are equal to 7.5 Gy and 5 centre dot 10 sup 8 Gy/s, respectively.

  5. Radioprotection in the operation of accelerator and plasma units

    International Nuclear Information System (INIS)

    Ewen, K.

    1984-01-01

    Relatively great problems of radioprotection can be caused by accelerator units, above all in the field of science, because all kinds of ionizing radiation and radioactive substances can be produced in all stages of aggregation. Furthermore, activities with relatively long half-lifes are induced by high particle streams with energies beyond the thresholds of many nuclear reations, to that the conditions of a control zone, even of a prohibited zone exist at many points after having switched off the accelerator. Not all of these radioprotective problems can be solved by constructive or technical measures. A sufficient skill of the persons responsible for radioprotection is very important in this connection. Efficient radioprotective measures are only possible by a close cooperation between the radiation protection officer, the competent authority, and the expert. (orig.) [de

  6. An accelerated conjugate gradient algorithm to compute low-lying eigenvalues - a study for the Dirac operator in SU(2) lattice QCD

    International Nuclear Information System (INIS)

    Kalkreuter, T.; Simma, H.

    1995-07-01

    The low-lying eigenvalues of a (sparse) hermitian matrix can be computed with controlled numerical errors by a conjugate gradient (CG) method. This CG algorithm is accelerated by alternating it with exact diagonalizations in the subspace spanned by the numerically computed eigenvectors. We study this combined algorithm in case of the Dirac operator with (dynamical) Wilson fermions in four-dimensional SU(2) gauge fields. The algorithm is numerically very stable and can be parallelized in an efficient way. On lattices of sizes 4 4 - 16 4 an acceleration of the pure CG method by a factor of 4 - 8 is found. (orig.)

  7. Model-based accelerator controls: What, why and how

    International Nuclear Information System (INIS)

    Sidhu, S.S.

    1987-01-01

    Model-based control is defined as a gamut of techniques whose aim is to improve the reliability of an accelerator and enhance the capabilities of the operator, and therefore of the whole control system. The aim of model-based control is seen as gradually moving the function of model-reference from the operator to the computer. The role of the operator in accelerator control and the need for and application of model-based control are briefly summarized

  8. Accelerator Technology Division annual report, FY 1991

    International Nuclear Information System (INIS)

    1992-04-01

    This report discusses the following programs: The Ground Test Accelerator Program; APLE Free-Electron Laser Program; Accelerator Transmutation of Waste; JAERI, OMEGA Project, and Intense Neutron Source for Materials Testing; Advanced Free-Electron Laser Initiative; Superconducting Super Collider; The High-Power Microwave Program; Φ Factory Collaboration; Neutral Particle Beam Power System Highlights; Accelerator Physics and Special Projects; Magnetic Optics and Beam Diagnostics; Accelerator Design and Engineering; Radio-Frequency Technology; Free-Electron Laser Technology; Accelerator Controls and Automation; Very High-Power Microwave Sources and Effects; and GTA Installation, Commissioning, and Operations

  9. Multigrid methods for S/sub N/ problems

    International Nuclear Information System (INIS)

    Nowak, P.F.; Larsen, E.W.; Martin, W.R.

    1987-01-01

    It has long been known that the standard source iteration (SI) method for obtaining iterative solutions of S/sub N/ problems is very slowly converging in optically thick regions with low absorption. The rebalance and diffusion synthetic acceleration (DSA) methods are generalizations of SI that have been developed to accelerate convergence, but neither of these methods has been completely successful. In particular, the rebalance method tends to become unstable in problems where it is needed most (problems with high scattering ratios c = 1), while the DSA method, to be implemented in a stable fashion, requires the solution of a particular system of acceleration equations, and this has been done efficiently in two-dimensional geometries only for the diamond difference S/sub N/ equations. This paper discusses another extension of the SI method, namely, SI combined with the spatial multigrid algorithm (SIMG). This appears to be a viable way to accelerate many S/sub N/ problems in multidimensional geometries, provided the finest mesh consists of cells that are not optically thick

  10. Magazine for handling stripping foils in a particle accelerator

    International Nuclear Information System (INIS)

    Gorka, A.J. Jr.

    1975-01-01

    Thin foils for stripping a particle beam are stored in a magazine that is operable remotely to display an individual foil, release it when it is spent, and repeat this process. The magazine is operable in the high-vacuum, high-radiation environment in the interior of a particle accelerator, and it uses the magnetic field of the accelerator to operate the display and dropping mechanism. (U.S.)

  11. Important requirements for RF generators for Accelerator-Driven Transmutation Technologies (ADTT)

    International Nuclear Information System (INIS)

    Lynch, M.T.; Tallerico, P.J.; Lawrence, G.P.

    1994-01-01

    All Accelerator-Driven Transmutation applications require very large amounts of RF Power. For example, one version of a Plutonium burning system requires an 800-MeV, 80-mA, proton accelerator running at 100% duty factor. This accelerator requires approximately 110-MW of continuous RF power if one assumes only 10% reserve power for control of the accelerator fields. In fact, to minimize beam spill, the RF controls may need as much as 15 to 20% of reserve power. In addition, unlike an electron accelerator in which the beam is relativistic, a failed RF station can disturb the synchronism of the beam, possibly shutting down the entire accelerator. These issues and more lead to a set of requirements for the RF generators which are stringent, and in some cases, conflicting. In this paper, we will describe the issues and requirements, and outline a plan for RF generator development to meet the needs of the Accelerator-Driven Transmutation Technologies. The key issues which will be discussed include: operating efficiency, operating linearity, effect on the input power grid, bandwidth, gain, reliability, operating voltage, and operating current

  12. The Next Linear Collider Test Accelerator

    International Nuclear Information System (INIS)

    Ruth, R.D.; Adolphsen, C.; Bane, K.

    1993-04-01

    During the past several years, there has been tremendous progress the development of the RF system and accelerating structures for a Next Linear Collider (NLC). Developments include high-power klystrons, RF pulse compression systems and damped/detuned accelerator structures to reduce wakefields. In order to integrate these separate development efforts into an actual X-band accelerator capable of accelerating the electron beams necessary for an NLC, we are building an NLC Test Accelerator (NLCTA). The goal of the NLCTA is to bring together all elements of the entire accelerating system by constructing and reliably operating an engineered model of a high-gradient linac suitable for the NLC. The NLCTA will serve as a testbed as the design of the NLC evolves. In addition to testing the RF acceleration system, the NLCTA is designed to address many questions related to the dynamics of the beam during acceleration. In this paper, we will report oil the status of the design, component development, and construction of the NLC Test Accelerator

  13. Performance of resistance grading system at 14 UD Pelletron Accelerator Facility, BARC-TIFR, Mumbai

    International Nuclear Information System (INIS)

    Lal, Ram; Matkar, U.V.; Ekambaram, M.; Lokare, R.N.; Yadav, M.L.; Gore, J.A.; Kulkarni, S.G.; Gupta, A.K.; Bhagwat, P.V.; Kale, R.M.; Karande, J.N.; Kurup, M.B.

    2005-01-01

    The 14UD Pelletron Accelerator has been in operation for last sixteen years, progressively with increased efficiency. Since inception the accelerator was operating in slit control mode, however, with the installation of a TPS system, it is now possible to operate the accelerator in GVM mode even with ion beam of low intensities. Recently all the column and tube corona points were replaced by resistances. This has helped in low voltage operation of accelerator. In this paper we will discuss in detail the performance of new Terminal Potential Stabiliser system, particularly, our experience resistance grading, at the Pelletron Accelerator. (author)

  14. Economic feasibility study to Raise the operational capacity of the Electron Beam Accelerator at the National Centre for Radiation Research and Technology, atomic Energy Authority, Egypt

    International Nuclear Information System (INIS)

    El-Kolaly, M.; Hammad, A.; El-Gameel, E.A.

    2011-01-01

    The study aims to investigate the economic feasibility to raise the operational capacity of the accelerator at the National Center for Radiation Research and Technology, Atomic Energy Authority, Egypt, through proposal of additional processing of power cables as it have 4 thousand operating hours per year of total 6 thousand hours per year. The study involved three sections; the first section included the technical aspects and marketing, the second section was concerned with financial analysis, and the third section included the national return of the project. In the first part, the electronic and technical requirements of the accelerator were studied to raise the capacity of the accelerator and to identify the time trend of demand for services in marketing. The second section included the financial feasibility of the project which was carried out through two parts; the first part deal with the analysis of costs of the project including identifying of investment, spending, labor costs, operating expenses, the annual installment of the annual depreciation expense with the total annual costs and operating costs per hour and ton. The second part was carried out to evaluated business profitability of the project, preparation of the annual cash flow, calculation of the internal rate of return, payback period of capital, and the analysis of sensitivity of the project in terms of its ability to achieve profitable business in the event of increasing costs and decreasing revenue. The third section was carried out to raise the operational capacity of the accelerator at the Egyptian Atomic Energy Authority to generate added value for national income, and to study the social rate of return for the project and examine the project's ability to provide new employment opportunities. The study showed the possibility and the importance of the project implemented at the level of private investment and national security.

  15. Electrostatic accelerators fundamentals and applications

    CERN Document Server

    2005-01-01

    Electrostatic accelerators are an important and widespread subgroup within the broad spectrum of modern, large particle acceleration devices. They are specifically designed for applications that require high-quality ion beams in terms of energy stability and emittance at comparatively low energies (a few MeV). Their ability to accelerate virtually any kind of ion over a continuously tunable range of energies make them a highly versatile tool for investigations in many research fields including, but not limited to, atomic and nuclear spectroscopy, heavy ion reactions, accelerator mass spectroscopy as well as ion-beam analysis and modification. The book is divided into three parts. The first part concisely introduces the field of accelerator technology and techniques that emphasize their major modern applications. The second part treats the electrostatic accelerator per se: its construction and operational principles as well as its maintenance. The third part covers all relevant applications in which electrosta...

  16. Preliminary Determination of Activation Products for a Varian Truebeam Linear Accelerator.

    Science.gov (United States)

    Waller, Edward; Ram, Rohan; Steadman, Ian

    2017-09-01

    Medical linear accelerators used to treat various forms of cancers are operated at a number of different energies. A by-product of the high-energy photons produced by accelerators is activation of components within the machine itself and its surrounding bunker. The activation products pose radiological and regulatory challenges during the operation of the accelerator as well as when it is time for final decommissioning. The Varian TrueBeam is a new state-of-the-art linear accelerator now operating in the Canadian market. There is currently limited information on the production of its activation products and the resulting impacts on operation and decommissioning. In this paper, activation products in the Varian TrueBeam accelerator are experimentally determined by performing gamma spectroscopy using a portable high purity germanium detector. A total of 10 isotopes are identified for the conditions tested, which include Na, Al, Mn, Ni, Cu, Cu, Br, Sb, Sb, W. The half-lives of these isotopes range from 2.3 min to 60.2 d. These preliminary results indicate that a decommissioning case similar to other radiotherapy accelerators can be made.

  17. Multimodal imaging in the elastase-induced aneurysm model in rabbits: a comparative study using serial DSA, MRA and CTA

    International Nuclear Information System (INIS)

    Doerfler, A.; Becker, W.; Wanke, I.; Goericke, S.; Oezkan, N.; Forsting, M.

    2004-01-01

    Background and Purpose: The elastase-induced aneurysm model in rabbits has proved to be suitable for testing new endovascular occlusion devices. The purpose of this study was to evaluate different imaging modalities for the depiction of anatomy and size of elastase-induced aneurysms and for serial follow-up imaging. Materials and Methods: Elastase-induced aneurysms were created in eight Chinchilla bastard rabbits by endoluminal incubation of porcine elastase. Serial imaging was performed using intravenous DSA (IVDSA), contrast-enhanced MRA (CEMRA), and time-of-flight MRA (TOF) 14 days, 4 weeks and 3 months after aneurysm creation. Intraarterial DSA (IADSA) and CT angiography (CTA) were performed after 3 months. Aneurysm size and geometry (height H, width W, neck width N) were compared. Results: On IVDSA after two weeks mean aneurysm height was 6.2 mm (range 2.8-11.0 mm), mean aneurysm neck width was 2.7 mm (range 2.0-4.2 mm) and mean aneurysm neck width was 2.7 mm (range 2.0-4.2 mm). We did not observed any statistically significant change in aneurysm dimensions during follow-up at 4 weeks (CEMRA: H: 5.4, W: 2.4, N: 2.4; TOF: H: 5.7, W: 2.4, N: 2.7) and 3 months (CEMRA: H: 5.8, W: 2.6, N: 2.6; TOF: H: 6.9, W: 2.8, N: 3.0). Aneurysm dimensions could be best seen on IADSA (H: 6.2, W: 3.0, N: 2.7) with good correlation to CTA (r=0.94; H: 6.1, W: 2.8, N: 2.6), CE-MRA (r=0.92), and TOF (r=0.97). TOF was superior to CEMRA in delineating the aneurysm wall. Conclusions: Serial imaging using MRA, CTA or intravenous and intraarterial angiography is feasible in the elastase-induced aneurysm model. Contrast-enhanced MRA, TOF-MRA and CTA showed good correlation to IADSA and are all suitable for non-invasive pretherapeutic measurement of aneurysm size. (orig.) [de

  18. Accelerator Technology Division progress report, FY 1993

    International Nuclear Information System (INIS)

    Schriber, S.O.; Hardekopf, R.A.; Heighway, E.A.

    1993-01-01

    This report discusses the following topics: A Next-Generation Spallation-Neutron Source; Accelerator Performance Demonstration Facility; APEX Free-Electron Laser Project; The Ground Test Accelerator (GTA) Program; Intense Neutron Source for Materials Testing; Linac Physics and Special Projects; Magnetic Optics and Beam Diagnostics; Radio-Frequency Technology; Accelerator Controls and Automation; Very High-Power Microwave Sources and Effects; and GTA Installation, Commissioning, and Operation

  19. Physics design of an accelerator for an accelerator-driven subcritical system

    Directory of Open Access Journals (Sweden)

    Zhihui Li

    2013-08-01

    Full Text Available An accelerator-driven subcritical system (ADS program was launched in China in 2011, which aims to design and build an ADS demonstration facility with the capability of more than 1000 MW thermal power in multiple phases lasting about 20 years. The driver linac is defined to be 1.5 GeV in energy, 10 mA in current and in cw operation mode. To meet the extremely high reliability and availability, the linac is designed with much installed margin and fault tolerance, including hot-spare injectors and local compensation method for key element failures. The accelerator complex consists of two parallel 10-MeV injectors, a joint medium-energy beam transport line, a main linac, and a high-energy beam transport line. The superconducting acceleration structures are employed except for the radio frequency quadrupole accelerators (RFQs which are at room temperature. The general design considerations and the beam dynamics design of the driver linac complex are presented here.

  20. Simultaneous Modeling of Gradual SEP Events at the Earth and the Mars

    Science.gov (United States)

    Hu, J.; Li, G.

    2017-12-01

    Solar Energetic Particles (SEP) event is the number one space hazard for spacecraft instruments and astronauts' safety. Recent studies have shown that both longitudinal and radial extent of SEP events can be very significant. In this work, we use the improved Particle Acceleration and Transport in the Heliosphere (iPATH) model to simulate gradual SEP events that have impacts upon both the Earth and the Mars. We follow the propagation of a 2D CME-driven shock. Particles are accelerated at the shock via the diffusive shock acceleration (DSA) mechanism. Transport of the escaped particles to the Earth and the Mars is then followed using a backward stochastic differential equation method. Perpendicular diffusion is considered in both the DSA and the transport process. Model results such as time intensity profile and energetic particle spectrum at the two locations are compared to understand the spatial extent of an SEP event. Observational data at the Earth and the Mars are also studied to validate the model.