WorldWideScience

Sample records for accelerating sequential programs

  1. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  2. Sequential accelerated tests: Improving the correlation of accelerated tests to module performance in the field

    Science.gov (United States)

    Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John

    2016-09-01

    DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.

  3. A Bayesian Optimal Design for Sequential Accelerated Degradation Testing

    Directory of Open Access Journals (Sweden)

    Xiaoyang Li

    2017-07-01

    Full Text Available When optimizing an accelerated degradation testing (ADT plan, the initial values of unknown model parameters must be pre-specified. However, it is usually difficult to obtain the exact values, since many uncertainties are embedded in these parameters. Bayesian ADT optimal design was presented to address this problem by using prior distributions to capture these uncertainties. Nevertheless, when the difference between a prior distribution and actual situation is large, the existing Bayesian optimal design might cause some over-testing or under-testing issues. For example, the implemented ADT following the optimal ADT plan consumes too much testing resources or few accelerated degradation data are obtained during the ADT. To overcome these obstacles, a Bayesian sequential step-down-stress ADT design is proposed in this article. During the sequential ADT, the test under the highest stress level is firstly conducted based on the initial prior information to quickly generate degradation data. Then, the data collected under higher stress levels are employed to construct the prior distributions for the test design under lower stress levels by using the Bayesian inference. In the process of optimization, the inverse Gaussian (IG process is assumed to describe the degradation paths, and the Bayesian D-optimality is selected as the optimal objective. A case study on an electrical connector’s ADT plan is provided to illustrate the application of the proposed Bayesian sequential ADT design method. Compared with the results from a typical static Bayesian ADT plan, the proposed design could guarantee more stable and precise estimations of different reliability measures.

  4. A Trust-region-based Sequential Quadratic Programming Algorithm

    DEFF Research Database (Denmark)

    Henriksen, Lars Christian; Poulsen, Niels Kjølstad

    This technical note documents the trust-region-based sequential quadratic programming algorithm used in other works by the authors. The algorithm seeks to minimize a convex nonlinear cost function subject to linear inequalty constraints and nonlinear equality constraints.......This technical note documents the trust-region-based sequential quadratic programming algorithm used in other works by the authors. The algorithm seeks to minimize a convex nonlinear cost function subject to linear inequalty constraints and nonlinear equality constraints....

  5. S.M.P. SEQUENTIAL MATHEMATICS PROGRAM.

    Science.gov (United States)

    CICIARELLI, V; LEONARD, JOSEPH

    A SEQUENTIAL MATHEMATICS PROGRAM BEGINNING WITH THE BASIC FUNDAMENTALS ON THE FOURTH GRADE LEVEL IS PRESENTED. INCLUDED ARE AN UNDERSTANDING OF OUR NUMBER SYSTEM, AND THE BASIC OPERATIONS OF WORKING WITH WHOLE NUMBERS--ADDITION, SUBTRACTION, MULTIPLICATION, AND DIVISION. COMMON FRACTIONS ARE TAUGHT IN THE FIFTH, SIXTH, AND SEVENTH GRADES. A…

  6. Micro-computer based control system and its software for carrying out the sequential acceleration on SMCAMS

    International Nuclear Information System (INIS)

    Li Deming

    2001-01-01

    Micro-computer based control system and its software for carrying out the sequential acceleration on SMCAMS is described. Also, the establishment of the 14 C particle measuring device and the improvement of the original power supply system are described

  7. From sequential to parallel programming with patterns

    CERN Document Server

    CERN. Geneva

    2018-01-01

    To increase in both performance and efficiency, our programming models need to adapt to better exploit modern processors. The classic idioms and patterns for programming such as loops, branches or recursion are the pillars of almost every code and are well known among all programmers. These patterns all have in common that they are sequential in nature. Embracing parallel programming patterns, which allow us to program for multi- and many-core hardware in a natural way, greatly simplifies the task of designing a program that scales and performs on modern hardware, independently of the used programming language, and in a generic way.

  8. STABILIZED SEQUENTIAL QUADRATIC PROGRAMMING: A SURVEY

    Directory of Open Access Journals (Sweden)

    Damián Fernández

    2014-12-01

    Full Text Available We review the motivation for, the current state-of-the-art in convergence results, and some open questions concerning the stabilized version of the sequential quadratic programming algorithm for constrained optimization. We also discuss the tools required for its local convergence analysis, globalization challenges, and extentions of the method to the more general variational problems.

  9. Intimately coupling of photolysis accelerates nitrobenzene biodegradation, but sequential coupling slows biodegradation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Lihui [Department of Environmental Science and Engineering, College of Life and Environmental Science, Shanghai Normal University, Shanghai 200234 (China); Zhang, Yongming, E-mail: zhym@shnu.edu.cn [Department of Environmental Science and Engineering, College of Life and Environmental Science, Shanghai Normal University, Shanghai 200234 (China); Bai, Qi; Yan, Ning; Xu, Hua [Department of Environmental Science and Engineering, College of Life and Environmental Science, Shanghai Normal University, Shanghai 200234 (China); Rittmann, Bruce E. [Swette Center for Environmental Biotechnology, Biodesign Institute, Arizona State University, Tempe, AZ 85287-5701 (United States)

    2015-04-28

    Highlights: • Intimately coupled UV photolysis accelerated nitrobenzene biodegradation. • NB biodegradation was slowed by accumulation of nitrophenol. • Oxalic acid was a key product of UV photolysis. • Oxalic acid accelerated biodegradation of nitrobenzene and nitrophenol by a co-substrate effect. • Intimate coupling of UV and biodegradation accentuated the benefits of oxalic acid. - Abstract: Photo(cata)lysis coupled with biodegradation is superior to photo(cata)lysis or biodegradation alone for removal of recalcitrant organic compounds. The two steps can be carried out sequentially or simultaneously via intimate coupling. We studied nitrobenzene (NB) removal and mineralization to evaluate why intimate coupling of photolysis with biodegradation was superior to sequential coupling. Employing an internal circulation baffled biofilm reactor, we compared direct biodegradation (B), biodegradation after photolysis (P + B), simultaneous photolysis and biodegradation (P&B), and biodegradation with nitrophenol (NP) and oxalic acid (OA) added individually and simultaneously (B + NP, B + OA, and B + NP + OA); NP and OA were NB’s main UV-photolysis products. Compared with B, the biodegradation rate P + B was lower by 13–29%, but intimately coupling (P&B) had a removal rate that was 10–13% higher; mineralization showed similar trends. B + OA gave results similar to P&B, B + NP gave results similar to P + B, and B + OA + NP gave results between P + B and P&B, depending on the amount of OA and NP added. The photolysis product OA accelerated NB biodegradation through a co-substrate effect, but NP was inhibitory. Although decreasing the UV photolysis time could minimize the inhibition impact of NP in P + B, P&B gave the fastest removal of NB by accentuating the co-substrate effect of OA.

  10. Intimately coupling of photolysis accelerates nitrobenzene biodegradation, but sequential coupling slows biodegradation

    International Nuclear Information System (INIS)

    Yang, Lihui; Zhang, Yongming; Bai, Qi; Yan, Ning; Xu, Hua; Rittmann, Bruce E.

    2015-01-01

    Highlights: • Intimately coupled UV photolysis accelerated nitrobenzene biodegradation. • NB biodegradation was slowed by accumulation of nitrophenol. • Oxalic acid was a key product of UV photolysis. • Oxalic acid accelerated biodegradation of nitrobenzene and nitrophenol by a co-substrate effect. • Intimate coupling of UV and biodegradation accentuated the benefits of oxalic acid. - Abstract: Photo(cata)lysis coupled with biodegradation is superior to photo(cata)lysis or biodegradation alone for removal of recalcitrant organic compounds. The two steps can be carried out sequentially or simultaneously via intimate coupling. We studied nitrobenzene (NB) removal and mineralization to evaluate why intimate coupling of photolysis with biodegradation was superior to sequential coupling. Employing an internal circulation baffled biofilm reactor, we compared direct biodegradation (B), biodegradation after photolysis (P + B), simultaneous photolysis and biodegradation (P&B), and biodegradation with nitrophenol (NP) and oxalic acid (OA) added individually and simultaneously (B + NP, B + OA, and B + NP + OA); NP and OA were NB’s main UV-photolysis products. Compared with B, the biodegradation rate P + B was lower by 13–29%, but intimately coupling (P&B) had a removal rate that was 10–13% higher; mineralization showed similar trends. B + OA gave results similar to P&B, B + NP gave results similar to P + B, and B + OA + NP gave results between P + B and P&B, depending on the amount of OA and NP added. The photolysis product OA accelerated NB biodegradation through a co-substrate effect, but NP was inhibitory. Although decreasing the UV photolysis time could minimize the inhibition impact of NP in P + B, P&B gave the fastest removal of NB by accentuating the co-substrate effect of OA

  11. High intensity proton accelerator program

    International Nuclear Information System (INIS)

    Kaneko, Yoshihiko; Mizumoto, Motoharu; Nishida, Takahiko

    1991-06-01

    Industrial applications of proton accelerators to the incineration of the long-lived nuclides contained in the spent fuels have long been investigated. Department of Reactor Engineering of Japan Atomic Energy Research Institute (JAERI) has formulated the Accelerator Program through the investigations on the required performances of the accelerator and its development strategies and also the research plan using the accelerator. Outline of the Program is described in the present report. The target of the Program is the construction of the Engineering Test Accelerators (ETA) of the type of a linear accelerator with the energy 1.5 GeV and the proton current ∼10 mA. It is decided that the construction of the Basic Technology Accelerator (BTA) is necessary as an intermediate step, aiming at obtaining the required technical basis and human resources. The Basic Technology Accelerator with the energy of 10 MeV and with the current of ∼10 mA is composed of the ion source, RFQ and DTL, of which system forms the mock-up of the injector of ETA. Development of the high-β structure which constitutes the main acceleration part of ETA is also scheduled. This report covers the basic parameters of the Basic Technology Accelerator (BTA), development steps of the element and system technologies of the high current accelerators and rough sketch of ETA which can be prospected at present. (J.P.N.)

  12. Simultaneous versus Sequential Accelerated Corneal Collagen Cross-Linking and Wave Front Guided PRK for Treatment of Keratoconus: Objective and Subjective Evaluation.

    Science.gov (United States)

    Abou Samra, Waleed Ali; El Emam, Dalia Sabry; Farag, Rania Kamel; Abouelkheir, Hossam Youssef

    2016-01-01

    Aim . To compare objective and subjective outcome after simultaneous wave front guided (WFG) PRK and accelerated corneal cross-linking (CXL) in patients with progressive keratoconus versus sequential WFG PRK 6 months after CXL. Methods . 62 eyes with progressive keratoconus were divided into two groups; the first including 30 eyes underwent simultaneous WFG PRK with accelerated CXL. The second including 32 eyes underwent subsequent WFG PRK performed 6 months later after accelerated CXL. Visual, refractive, topographic, and aberrometric data were determined preoperatively and during 1-year follow-up period and the results compared in between the 2 studied groups. Results . All evaluated visual, refractive, and aberrometric parameters demonstrated highly significant improvement in both studied groups (all P PRK and accelerated CXL is an effective and safe option to improve the vision in mild to moderate keratoconus. In one-year follow-up, there is no statistically significant difference between the simultaneous and sequential procedure.

  13. FERMILAB ACCELERATOR R&D PROGRAM TOWARDS INTENSITY FRONTIER ACCELERATORS : STATUS AND PROGRESS

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, Vladimir [Fermilab

    2016-11-15

    The 2014 P5 report indicated the accelerator-based neutrino and rare decay physics research as a centrepiece of the US domestic HEP program at Fermilab. Operation, upgrade and development of the accelerators for the near- term and longer-term particle physics program at the Intensity Frontier face formidable challenges. Here we discuss key elements of the accelerator physics and technology R&D program toward future multi-MW proton accelerators and present its status and progress. INTENSITY FRONTIER ACCELERATORS

  14. Simple and flexible SAS and SPSS programs for analyzing lag-sequential categorical data.

    Science.gov (United States)

    O'Connor, B P

    1999-11-01

    This paper describes simple and flexible programs for analyzing lag-sequential categorical data, using SAS and SPSS. The programs read a stream of codes and produce a variety of lag-sequential statistics, including transitional frequencies, expected transitional frequencies, transitional probabilities, adjusted residuals, z values, Yule's Q values, likelihood ratio tests of stationarity across time and homogeneity across groups or segments, transformed kappas for unidirectional dependence, bidirectional dependence, parallel and nonparallel dominance, and significance levels based on both parametric and randomization tests.

  15. Simultaneous versus Sequential Accelerated Corneal Collagen Cross-Linking and Wave Front Guided PRK for Treatment of Keratoconus: Objective and Subjective Evaluation

    Directory of Open Access Journals (Sweden)

    Waleed Ali Abou Samra

    2016-01-01

    Full Text Available Aim. To compare objective and subjective outcome after simultaneous wave front guided (WFG PRK and accelerated corneal cross-linking (CXL in patients with progressive keratoconus versus sequential WFG PRK 6 months after CXL. Methods. 62 eyes with progressive keratoconus were divided into two groups; the first including 30 eyes underwent simultaneous WFG PRK with accelerated CXL. The second including 32 eyes underwent subsequent WFG PRK performed 6 months later after accelerated CXL. Visual, refractive, topographic, and aberrometric data were determined preoperatively and during 1-year follow-up period and the results compared in between the 2 studied groups. Results. All evaluated visual, refractive, and aberrometric parameters demonstrated highly significant improvement in both studied groups (all P<0.001. A significant improvement was observed in keratometric and Q values. The improvement in all parameters was stable till the end of follow-up. Likewise, no significant difference was determined in between the 2 groups in any of recorded parameters. Subjective data revealed similarly significant improvement in both groups. Conclusions. WFG PRK and accelerated CXL is an effective and safe option to improve the vision in mild to moderate keratoconus. In one-year follow-up, there is no statistically significant difference between the simultaneous and sequential procedure.

  16. New heavy-ion-fusion accelerator research program

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1983-05-01

    This paper will briefly summarize the concepts of Heavy Ion Fusion (HIF), especially those aspects that are important to its potential for generating electrical power. It will also note highlights of the various HIF programs throughout the world. Especially significant is that the US Department of Energy (DOE) plans a program, beginning in 1984, aimed at determining the feasibility of using heavy ion accelerators as drivers for Inertial Confinement Fusion (ICF). The new program concentrates on the aspects of accelerator design that are important to ICF, and for this reason is called HIF Accelerator Research

  17. The intense proton accelerator program

    International Nuclear Information System (INIS)

    Kaneko, Yoshihiko

    1990-01-01

    The Science and Technology Agency of Japan has formulated the OMEGA project, in which incineration of nuclear wastes by use of accelerators is defined as one of the important tasks. Japan Atomic Energy Research Institute (JAERI) has been engaged for several years in basic studies in incineration technology with use of an intense proton linear accelerator. The intense proton accelerator program intends to provide a large scale proton linear accelerator called Engineering Test Accelerator. The principal purpose of the accelerator is to develop nuclear waste incineration technology. The accelerator will also be used for other industrial applications and applied science studies. The present report further outlines the concept of incineration of radio-activities of nuclear wastes, focusing on nuclear reactions and a concept of incineration plant. Features of Engineering Test Accelerator are described focusing on the development of the accelerator, and research and development of incineration technology. Applications of science and technology other than nuclear waste incineration are also discussed. (N.K.)

  18. Development of computer-aided software engineering tool for sequential control of JT-60U

    International Nuclear Information System (INIS)

    Shimono, M.; Akasaka, H.; Kurihara, K.; Kimura, T.

    1995-01-01

    Discharge sequential control (DSC) is an essential control function for the intermittent and pulse discharge operation of a tokamak device, so that many subsystems may work with each other in correct order and/or synchronously. In the development of the DSC program, block diagrams of logical operation for sequential control are illustrated in its design at first. Then, the logical operators and I/O's which are involved in the block diagrams are compiled and converted to a certain particular form. Since the block diagrams of the sequential control amounts to about 50 sheets in the case of the JT-60 upgrade tokamak (JT-60U) high power discharge and the above steps of the development have been performed manually so far, a great effort has been required for the program development. In order to remove inefficiency in such development processes, a computer-aided software engineering (CASE) tool has been developed on a UNIX workstation. This paper reports how the authors design it for the development of the sequential control programs. The tool is composed of the following three tools: (1) Automatic drawing tool, (2) Editing tool, and (3) Trace tool. This CASE tool, an object-oriented programming tool having graphical formalism, can powerfully accelerate the cycle for the development of the sequential control function commonly associated with pulse discharge in a tokamak fusion device

  19. US Accelerator R&D Program Toward Intensity Frontier Machines

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, Vladimir [Fermilab

    2016-09-15

    The 2014 P5 report indicated the accelerator-based neutrino and rare decay physics research as a centerpiece of the US domestic HEP program. Operation, upgrade and development of the accelerators for the near-term and longer-term particle physics program at the Intensity Frontier face formidable challenges. Here we discuss key elements of the accelerator physics and technology R&D program toward future multi-MW proton accelerators.

  20. The BNL Accelerator Test Facility and experimental program

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; State Univ. of New York, Stony Brook, NY

    1992-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high-power laser pulses synchronized to the electron beam, suitable for studies of new methods of high-gradient acceleration and state-of-the-art Free-Electron Lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps ND:YAG laser and a 500 mJ, 10 to 100 ps C0 2 laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various laser acceleration schemes, Free-Electron Laser experiments and a program on the development of high-brightness electron beams. The ATF's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the high-power laser will begin operation this year

  1. The BNL Accelerator Test Facility and experimental program

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; State Univ. of New York, Stony Brook, NY

    1991-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high power laser pulses synchronized to the electron beam, suitable for studies of new methods of high gradient acceleration and state of the art free electron lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 to 100 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps Nd:YAG laser and a 100 mJ, 10 ps CO 2 laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various acceleration schemes, Free-Electron Laser experiments and a program on the development of high brightness electron beams. The AFT's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the High power laser will begin operation this year. 28 refs., 4 figs

  2. Acceleration of the FERM nodal program

    International Nuclear Information System (INIS)

    Nakata, H.

    1985-01-01

    It was tested three acceleration methods trying to reduce the number of outer iterations in the FERM nodal program. The results obtained indicated that the Chebychev polynomial acceleration method with variable degree results in a economy of 50% in the computer time. Otherwise, the acceleration method by source asymptotic extrapolation or by zonal rebalance did not result in economy of the global computer time, however some acceleration had been verified in outer iterations. (M.C.K.) [pt

  3. Accelerated Reader Program: What Do Teachers Really Think?

    Science.gov (United States)

    Smith, Amy Frances; Westberg, Karen; Hejny, Anne

    2017-01-01

    What do teachers really think about the Accelerated Reader program, a widely used supplemental, independent reading program in which their students read fiction and non-fiction books of their choice and take brief online comprehension quizzes about the books? The Accelerated Reader (AR) program was designed by Renaissance Learning Company to…

  4. Accelerated leach test development program

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Pietrzak, R.F.; Heiser, J.; Franz, E.M.; Colombo, P.

    1990-11-01

    In FY 1989, a draft accelerated leach test for solidified waste was written. Combined test conditions that accelerate leaching were validated through experimental and modeling efforts. A computer program was developed that calculates test results and models leaching mechanisms. This program allows the user to determine if diffusion controls leaching and, if this is the case, to make projections of releases. Leaching mechanisms other than diffusion (diffusion plus source term partitioning and solubility limited leaching) are included in the program is indicators of other processes that may control leaching. Leach test data are presented and modeling results are discussed for laboratory scale waste forms composed of portland cement containing sodium sulfate salt, portland cement containing incinerator ash, and vinyl ester-styrene containing sodium sulfate. 16 refs., 38 figs., 5 tabs

  5. Sequential injection approach for simultaneous determination of ultratrace plutonium and neptunium in urine with accelerator mass spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    An analytical method was developed for simultaneous determination of ultratrace level plutonium (Pu) and neptunium (Np) using iron hydroxide coprecipitation in combination with automated sequential injection extraction chromatography separation and accelerator mass spectrometry (AMS) measurement...... show that preboiling and aging are important for obtaining high chemical yields for both Pu and Np, which is possibly related to the aggregation and adsorption behavior of organic substances contained in urine. Although the optimal condition for Np and Pu simultaneous determination requires 5-day aging...

  6. Effective flow-accelerated corrosion programs in nuclear facilities

    International Nuclear Information System (INIS)

    Esselman, Thomas C.; McBrine, William J.

    2004-01-01

    Piping Flow-Accelerated Corrosion Programs in nuclear power generation facilities are classically comprised of the selection of inspection locations with the assistance of a predictive methodology such as the Electric Power Research Institute computer codes CHECMATE or CHECWORKS, performing inspections, conducting structural evaluations on the inspected components, and implementing the appropriate sample expansion and corrective actions. Performing such a sequence of steps can be effective in identifying thinned components and implementing appropriate short term and long term actions necessary to resolve flow-accelerated corrosion related problems. A maximally effective flow-accelerated corrosion (FAC) program requires an understanding of many programmatic details. These include the procedural control of the program, effective use of historical information, managing the activities performed during a limited duration outage, allocating resources based on risk allocation, having an acute awareness of how the plant is operated, investigating components removed from the plant, and several others. This paper will describe such details and methods that will lead to a flow-accelerated corrosion program that effectively minimizes the risk of failure due to flow-accelerated corrosion and provide full and complete documentation of the program. (author)

  7. A Sequential Convex Semidefinite Programming Algorithm for Multiple-Load Free Material Optimization

    Czech Academy of Sciences Publication Activity Database

    Stingl, M.; Kočvara, Michal; Leugering, G.

    2009-01-01

    Roč. 20, č. 1 (2009), s. 130-155 ISSN 1052-6234 R&D Projects: GA AV ČR IAA1075402 Grant - others:commision EU(XE) EU-FP6-30717 Institutional research plan: CEZ:AV0Z10750506 Keywords : structural optimization * material optimization * semidefinite programming * sequential convex programming Subject RIV: BA - General Mathematics Impact factor: 1.429, year: 2009

  8. XACC - eXtreme-scale Accelerator Programming Framework

    Energy Technology Data Exchange (ETDEWEB)

    2016-11-18

    Hybrid programming models for beyond-CMOS technologies will prove critical for integrating new computing technologies alongside our existing infrastructure. Unfortunately the software infrastructure required to enable this is lacking or not available. XACC is a programming framework for extreme-scale, post-exascale accelerator architectures that integrates alongside existing conventional applications. It is a pluggable framework for programming languages developed for next-gen computing hardware architectures like quantum and neuromorphic computing. It lets computational scientists efficiently off-load classically intractable work to attached accelerators through user-friendly Kernel definitions. XACC makes post-exascale hybrid programming approachable for domain computational scientists.

  9. Advanced Accelerator Applications University Participation Program

    International Nuclear Information System (INIS)

    Chen, Y.; Hechanova, A.

    2007-01-01

    Our research tasks span the range of technology areas for transmutation, gas-cooled reactor technology, and high temperature heat exchangers, including separation of actinides from spent nuclear fuel, methods of fuel fabrication, reactor-accelerator coupled experiments, corrosion of materials exposed to lead-bismuth eutectic, and special nuclear materials protection and accountability. In the six years of this program, we saw the evolution of the national transmutation concepts go from the use of accelerators to fast reactors. We also saw an emphasis on gas-cooled reactors for both high temperature heat and deep burn of nuclear fuel. At the local level, we saw a great birth at UNLV of two new academic programs Fall term of 2004 and the addition of 10 academic and research faculty. The Ph.D. program in Radiochemistry has turned into one of the nation's most visible and successful programs; and, the M.S. program in Materials and Nuclear Engineering initiated Nuclear Engineering academic opportunities which took a long time to come. Our research tasks span the range of technology areas for transmutation, gas-cooled reactor technology, and high temperature heat exchangers, including separation of actinides from spent nuclear fuel, methods of fuel fabrication, reactor-accelerator coupled experiments, corrosion of materials exposed to lead-bismuth eutectic, and special nuclear materials protection and accountability

  10. ORNL pellet acceleration program

    International Nuclear Information System (INIS)

    Foster, C.A.; Milora, S.L.

    1978-01-01

    The Oak Ridge National Laboratory (ORNL) pellet fueling program is centered around developing equipment to accelerate large pellets of solidified hydrogen to high speeds. This equipment will be used to experimentally determine pellet-plasma interaction physics on contemporary tokamaks. The pellet experiments performed on the Oak Ridge Tokamak (ORMAK) indicated that much larger, faster pellets would be advantageous. In order to produce and accelerate pellets of the order of 1 to 6 mm in diameter, two apparatuses have been designed and are being constructed. The first will make H 2 pellets by extruding a filament of hydrogen and mechanically chopping it into pellets. The pellets formed will be mechanically accelerated with a high speed arbor to a speed of 950 m/sec. This technique may be extended to speeds up to 5000 m/sec, which makes it a prime candidate for a reactor fueling device. In the second technique, a hydrogen pellet will be formed, loaded into a miniature rifle, and accelerated by means of high pressure hydrogen gas. This technique should be capable of speeds of the order of 1000 m/sec. While this technique does not offer the high performance of the mechanical accelerator, its relative simplicity makes it attractive for near-term experiments

  11. Career Maturity of Students in Accelerated versus Traditional Programs

    Science.gov (United States)

    Borges, Nicole J.; Richard, George V.; Duffy, Ryan D.

    2007-01-01

    The authors assessed the career maturity of students in accelerated versus traditional academic programs. Students in traditional programs were hypothesized to be more advanced regarding their career decision making and development when compared with students in accelerated programs. The Medical Career Development Inventory (see M. L. Savickas,…

  12. Quantum optical device accelerating dynamic programming

    OpenAIRE

    Grigoriev, D.; Kazakov, A.; Vakulenko, S.

    2005-01-01

    In this paper we discuss analogue computers based on quantum optical systems accelerating dynamic programming for some computational problems. These computers, at least in principle, can be realized by actually existing devices. We estimate an acceleration in resolving of some NP-hard problems that can be obtained in such a way versus deterministic computers

  13. Resource letter for Accelerated Matter Program

    International Nuclear Information System (INIS)

    Rossi, F.

    1989-07-01

    This resource letter covers diverse literature(400 titles) relevant to the Accelerated Matter Program in the Particles and Fields Group at the University of Melbourne. Specifically, the research areas covered are: inertia induced electric fields in accelerated matter; strain induced contact potentials; the patch effect/surface potentials. There are no claims made for completeness. The areas of gravity, acceleration and strain induced effects in matter, and drift tube experiments with matter/antimatter are extensively covered, if not complete. The literature on acceleration/inertia induced effects in metals has a long history dating back to the 19th century and the reader is referred to the review by Barnett (1935) for an extensive list of references not included here. All other work following this 1935 review, has been included here. The literature on surface physics is very extensive and no attempt has been made to cover it all. Every major paper on metal surfaces has been cited. Several other references have been included which fall only loosely into the above areas and they represent useful and/or interesting material for this research program

  14. Safety guidance and inspection program for particle accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Whey [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Lee, Hee Seock; Yeo, In Whan [Pohang Accelerator Laboratory, Pohang (Korea, Republic of)] (and others)

    2001-03-15

    The inspection program and the safety guidance were developed to enhance the radiation protection for the use of particle accelerators. First the classification of particle accelerators was conducted to develop the safety inspection protocol efficiently. The status of particle accelerators which were operated at the inside and outside of the country, and their safety programs were surveyed. The characteristics of radiation production was researched for each type of particle accelerators. Two research teams were launched for industrial and research accelerators and for medical accelerators, respectively. In each stages of a design, a fabrication, an installation, a commissioning, and normal operation of accelerators, those safety inspection protocols were developed. Because all protocols resulted from employing safety experts, doing the questionnaire, and direct facility surveys, it can be applicable to present safety problem directly. The detail improvement concepts were proposed to revise the domestic safety rule. This results might also be useful as a practical guidance for the radiation safety officer of an accelerator facility, and as the detail standard for the governmental inspection authorities.

  15. A Computer Program for Simplifying Incompletely Specified Sequential Machines Using the Paull and Unger Technique

    Science.gov (United States)

    Ebersole, M. M.; Lecoq, P. E.

    1968-01-01

    This report presents a description of a computer program mechanized to perform the Paull and Unger process of simplifying incompletely specified sequential machines. An understanding of the process, as given in Ref. 3, is a prerequisite to the use of the techniques presented in this report. This process has specific application in the design of asynchronous digital machines and was used in the design of operational support equipment for the Mariner 1966 central computer and sequencer. A typical sequential machine design problem is presented to show where the Paull and Unger process has application. A description of the Paull and Unger process together with a description of the computer algorithms used to develop the program mechanization are presented. Several examples are used to clarify the Paull and Unger process and the computer algorithms. Program flow diagrams, program listings, and a program user operating procedures are included as appendixes.

  16. University Programs of the U.S. Department of Energy Advanced Accelerator Applications Program

    International Nuclear Information System (INIS)

    Beller, Denis E.; Ward, Thomas E.; Bresee, James C.

    2002-01-01

    The Advanced Accelerator Applications (AAA) Program was initiated in fiscal year 2001 (FY-01) by the U.S. Congress, the U.S. Department of Energy (DOE), and the Los Alamos National Laboratory (LANL) in partnership with other national laboratories. The primary goal of this program is to investigate the feasibility of transmutation of nuclear waste. An Accelerator-Driven Test Facility (ADTF), which may be built during the first decade of the 21. Century, is a major component of this effort. The ADTF would include a large, state-of-the-art charged-particle accelerator, proton-neutron target systems, and accelerator-driven R and D systems. This new facility and its underlying science and technology will require a large cadre of educated scientists and trained technicians. In addition, other applications of nuclear science and engineering (e.g., proliferation monitoring and defense, nuclear medicine, safety regulation, industrial processes, and many others) require increased academic and national infrastructure and student populations. Thus, the AAA Program Office has begun a multi-year program to involve university faculty and students in various phases of the Project to support the infrastructure requirements of nuclear energy, science and technology fields as well as the special needs of the DOE transmutation program. In this paper we describe university programs that have supported, are supporting, and will support the R and D necessary for the AAA Project. Previous work included research for the Accelerator Transmutation of Waste (ATW) project, current (FY-01) programs include graduate fellowships and research for the AAA Project, and it is expected that future programs will expand and add to the existing programs. (authors)

  17. The TAO Accelerator Simulation Program

    CERN Document Server

    Sagan, David

    2005-01-01

    A new accelerator design and analysis simulation environment based on the BMAD relativistic charged particle dynamics library is in development at Cornell University. Called TAO (Tool for Accelerator Optimization), it is a machine independent program that implements the essential ingredients needed to solve simulation problems. This includes the ability to: 1. Design lattices subject to constraints, 2. Simulate errors and changes in machine parameters, and 3. Simulate machine commissioning including simulating data measurement and correction. TAO is designed to be easily customizable so that extending it to solve new and different problems is straight forward. The capability to simultaneously model multiple accelerator lattices, both linacs and storage rings, and injection from one lattice to another allows for the design and commissioning of large multi stage accelerators. It can also simultaneously model multiple configurations of a single lattice. Single particle, particle beam and macroparticle tracking i...

  18. Effective radiological safety program for electron linear accelerators

    International Nuclear Information System (INIS)

    Swanson, W.P.

    1980-10-01

    An outline is presented of some of the main elements of an electron accelerator radiological safety program. The discussion includes types of accelerator facilities, types of radiations to be anticipated, activity induced in components, air and water, and production of toxic gases. Concepts of radiation shielding design are briefly discussed and organizational aspects are considered as an integral part of the overall safety program

  19. Accelerated bridge paint test program.

    Science.gov (United States)

    2011-07-06

    The accelerated bridge paint (AB-Paint) program evaluated a new Sherwin-Williams two-coat, : fast-curing paint system. The system is comprised of an organic zinc-rich primer (SW Corothane I : Galvapac One-Pack Zinc-Rich Primer B65 G11) and a polyurea...

  20. The Computer Program LIAR for Beam Dynamics Calculations in Linear Accelerators

    International Nuclear Information System (INIS)

    Assmann, R.W.; Adolphsen, C.; Bane, K.; Raubenheimer, T.O.; Siemann, R.H.; Thompson, K.

    2011-01-01

    Linear accelerators are the central components of the proposed next generation of linear colliders. They need to provide acceleration of up to 750 GeV per beam while maintaining very small normalized emittances. Standard simulation programs, mainly developed for storage rings, do not meet the specific requirements for high energy linear accelerators. We present a new program LIAR ('LInear Accelerator Research code') that includes wakefield effects, a 6D coupled beam description, specific optimization algorithms and other advanced features. Its modular structure allows to use and to extend it easily for different purposes. The program is available for UNIX workstations and Windows PC's. It can be applied to a broad range of accelerators. We present examples of simulations for SLC and NLC.

  1. Large-scale sequential quadratic programming algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Eldersveld, S.K.

    1992-09-01

    The problem addressed is the general nonlinear programming problem: finding a local minimizer for a nonlinear function subject to a mixture of nonlinear equality and inequality constraints. The methods studied are in the class of sequential quadratic programming (SQP) algorithms, which have previously proved successful for problems of moderate size. Our goal is to devise an SQP algorithm that is applicable to large-scale optimization problems, using sparse data structures and storing less curvature information but maintaining the property of superlinear convergence. The main features are: 1. The use of a quasi-Newton approximation to the reduced Hessian of the Lagrangian function. Only an estimate of the reduced Hessian matrix is required by our algorithm. The impact of not having available the full Hessian approximation is studied and alternative estimates are constructed. 2. The use of a transformation matrix Q. This allows the QP gradient to be computed easily when only the reduced Hessian approximation is maintained. 3. The use of a reduced-gradient form of the basis for the null space of the working set. This choice of basis is more practical than an orthogonal null-space basis for large-scale problems. The continuity condition for this choice is proven. 4. The use of incomplete solutions of quadratic programming subproblems. Certain iterates generated by an active-set method for the QP subproblem are used in place of the QP minimizer to define the search direction for the nonlinear problem. An implementation of the new algorithm has been obtained by modifying the code MINOS. Results and comparisons with MINOS and NPSOL are given for the new algorithm on a set of 92 test problems.

  2. Fast acceleration of 2D wave propagation simulations using modern computational accelerators.

    Directory of Open Access Journals (Sweden)

    Wei Wang

    Full Text Available Recent developments in modern computational accelerators like Graphics Processing Units (GPUs and coprocessors provide great opportunities for making scientific applications run faster than ever before. However, efficient parallelization of scientific code using new programming tools like CUDA requires a high level of expertise that is not available to many scientists. This, plus the fact that parallelized code is usually not portable to different architectures, creates major challenges for exploiting the full capabilities of modern computational accelerators. In this work, we sought to overcome these challenges by studying how to achieve both automated parallelization using OpenACC and enhanced portability using OpenCL. We applied our parallelization schemes using GPUs as well as Intel Many Integrated Core (MIC coprocessor to reduce the run time of wave propagation simulations. We used a well-established 2D cardiac action potential model as a specific case-study. To the best of our knowledge, we are the first to study auto-parallelization of 2D cardiac wave propagation simulations using OpenACC. Our results identify several approaches that provide substantial speedups. The OpenACC-generated GPU code achieved more than 150x speedup above the sequential implementation and required the addition of only a few OpenACC pragmas to the code. An OpenCL implementation provided speedups on GPUs of at least 200x faster than the sequential implementation and 30x faster than a parallelized OpenMP implementation. An implementation of OpenMP on Intel MIC coprocessor provided speedups of 120x with only a few code changes to the sequential implementation. We highlight that OpenACC provides an automatic, efficient, and portable approach to achieve parallelization of 2D cardiac wave simulations on GPUs. Our approach of using OpenACC, OpenCL, and OpenMP to parallelize this particular model on modern computational accelerators should be applicable to other

  3. Panel discussion on laboratory accelerator programs: present and future

    International Nuclear Information System (INIS)

    Richter, B.

    1986-09-01

    The present SLAC accelerator program is summarized briefly, and the future of electron-positron colliders is discussed. Present activities discussed include the PEP storage ring, the SPEAR storage ring, the Linear Accelerator, and the SLAC Linear Collider (SLC) project. Future prospects include a larger scale linear collider. The stability requirements on acceleration are briefly discussed

  4. Ground test accelerator control system software

    International Nuclear Information System (INIS)

    Burczyk, L.; Dalesio, R.; Dingler, R.; Hill, J.; Howell, J.A.; Kerstiens, D.; King, R.; Kozubal, A.; Little, C.; Martz, V.; Rothrock, R.; Sutton, J.

    1988-01-01

    This paper reports on the GTA control system that provides an environment in which the automation of a state-of-the-art accelerator can be developed. It makes use of commercially available computers, workstations, computer networks, industrial 110 equipment, and software. This system has built-in supervisory control (like most accelerator control systems), tools to support continuous control (like the process control industry), and sequential control for automatic start-up and fault recovery (like few other accelerator control systems). Several software tools support these levels of control: a real-time operating system (VxWorks) with a real-time kernel (VRTX), a configuration database, a sequencer, and a graphics editor. VxWorks supports multitasking, fast context-switching, and preemptive scheduling. VxWorks/VRTX is a network-based development environment specifically designed to work in partnership with the UNIX operating system. A data base provides the interface to the accelerator components. It consists of a run time library and a database configuration and editing tool. A sequencer initiates and controls the operation of all sequence programs (expressed as state programs). A graphics editor gives the user the ability to create color graphic displays showing the state of the machine in either text or graphics form

  5. A Sequential Quadratically Constrained Quadratic Programming Method of Feasible Directions

    International Nuclear Information System (INIS)

    Jian Jinbao; Hu Qingjie; Tang Chunming; Zheng Haiyan

    2007-01-01

    In this paper, a sequential quadratically constrained quadratic programming method of feasible directions is proposed for the optimization problems with nonlinear inequality constraints. At each iteration of the proposed algorithm, a feasible direction of descent is obtained by solving only one subproblem which consist of a convex quadratic objective function and simple quadratic inequality constraints without the second derivatives of the functions of the discussed problems, and such a subproblem can be formulated as a second-order cone programming which can be solved by interior point methods. To overcome the Maratos effect, an efficient higher-order correction direction is obtained by only one explicit computation formula. The algorithm is proved to be globally convergent and superlinearly convergent under some mild conditions without the strict complementarity. Finally, some preliminary numerical results are reported

  6. Energy Innovation Acceleration Program

    Energy Technology Data Exchange (ETDEWEB)

    Wolfson, Johanna [Fraunhofer USA Inc., Center for Sustainable Energy Systems, Boston, MA (United States)

    2015-06-15

    The Energy Innovation Acceleration Program (IAP) – also called U-Launch – has had a significant impact on early stage clean energy companies in the Northeast and on the clean energy economy in the Northeast, not only during program execution (2010-2014), but continuing into the future. Key results include: Leverage ratio of 105:1; $105M in follow-on funding (upon $1M investment by EERE); At least 19 commercial products launched; At least 17 new industry partnerships formed; At least $6.5M in revenue generated; >140 jobs created; 60% of assisted companies received follow-on funding within 1 year of program completion; In addition to the direct measurable program results summarized above, two primary lessons emerged from our work executing Energy IAP:; Validation and demonstration awards have an outsized, ‘tipping-point’ effect for startups looking to secure investments and strategic partnerships. An ecosystem approach is valuable, but an approach that evaluates the needs of individual companies and then draws from diverse ecosystem resources to fill them, is most valuable of all.

  7. Remarks on sequential designs in risk assessment

    International Nuclear Information System (INIS)

    Seidenfeld, T.

    1982-01-01

    The special merits of sequential designs are reviewed in light of particular challenges that attend risk assessment for human population. The kinds of ''statistical inference'' are distinguished and the problem of design which is pursued is the clash between Neyman-Pearson and Bayesian programs of sequential design. The value of sequential designs is discussed and the Neyman-Pearson vs. Bayesian sequential designs are probed in particular. Finally, warnings with sequential designs are considered, especially in relation to utilitarianism

  8. Accelerator technology program. Progress report, January-December 1979

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, E.A.; Jameson, R.A. (comps.)

    1980-11-01

    The activities of Los Alamos Scientific Laboratory's (LASL) Accelerator Technology (AT) Division during the calendar year 1979 are highlighted, with references to more detailed reports. This report is organized around the major projects of the Division, reflecting a wide variety of applications and sponsors. The first section covers the Fusion Materials Irradiation Test program, a collaborative effort with the Hanford Engineering Development Laboratory; the second section summarizes progress on the Proton Storage Ring to be built between LAMPF and the LASL Pulsed Neutron Research facility. A new project that achieved considerable momentum during the year is described next - the free-electron laser studies; the following section discusses the status of the Pion Generator for Medical Irradiation program. Next, two more new programs, the racetrack microtron being developed jointly by AT-Division and the National Bureau of Standards and the radio-frequency (rf) accelerator development for heavy ion fusion, are outlined. Development activities on a new type of high-power, high-efficiency rf amplifier called the gyrocon are then reported, and the final sections cover development of H/sup -/ ion sources and injectors, and linear accelerator instrumentation and beam dynamics.

  9. JAERI R & D on accelerator-based transmutation under OMEGA program

    Energy Technology Data Exchange (ETDEWEB)

    Takizuka, T.; Nishida, T.; Mizumoto, M. [Japan Atomic Energy Research Institute, Ibaraki-ken (Japan)] [and others

    1995-10-01

    The overview of the Japanese long-term research and development program on nuclide partitioning and transmutation, called {open_quotes}OMEGA,{close_quotes} is presented. Under this national program, major R&D activities are being carried out at JAERI, PNC, and CRIEPI. Accelerator-based transmutation study at JAERI is focused on a dedicated transmutor with a subcritical actinide-fueled subcritical core coupled with a spallation target driven by a high intensity proton accelerator. Two types of system concept, solid system and molten-salt system, are discussed. The solid system consists of sodium-cooled tungsten target and metallic actinide fuel. The molten-salt system is fueled with molten actinide chloride that acts also as a target material. The proposed plant transmutes about 250 kg of minor actinide per year, and generates enough electricity to power its own accelerator. JAERI is proposing the development of an intense proton linear accelerator ETA with 1.5 GeV-10 mA beam for engineering tests of accelerator-based transmutation. Recent achievements in the accelerator development are described.

  10. U.S. advanced accelerator applications program: plans to develop and test waste transmutation technologies

    International Nuclear Information System (INIS)

    Van Tuyle, G.; Bennett, D.; Arthur, E.; Cappiello, M.; Finck, P.; Hill, D.; Herczeg, J.; Goldner, F.

    2001-01-01

    The primary mission of the U.S. Advanced Accelerator Applications (AAA) Program is to establish a national nuclear technology research capability that can demonstrate accelerator-based transmutation of waste and conduct transmutation research while at the same time providing a capability for the production of tritium if required. The AAA Program was created during fiscal year 2001 from the Accelerator Transmutation of Waste (ATW) Program and the Accelerator Production of Tritium (APT) Project. This paper describes the new AAA Program, as well as its two major components: development and testing of waste transmutation technologies and construction of an integrated accelerator-driven test facility (ADTF). (author)

  11. State registration and inspection programs for particle accelerators

    International Nuclear Information System (INIS)

    Bailey, E.D.

    1976-01-01

    The Suggested State Regulations for Control of Radiation(SSRCR) are recommended by the Council of State Governments and the National Conference of Radiation Control Program Directors as the model regulations which states should adopt in order to have adequate regulation and uniformity from state to state. These regulations are used as a basis for reviewing the current status of accelerator regulation in each state. The SSRCR does contain a separate part for registration (Part B--Registration of Radiation Machine Facilities and Services) and a separate part (Part I--Radiation Safety Requirements for Particle Accelerators) with specific requirements for the possession and use of accelerators. In addition, medical accelerators have additional requirements in Part F--X-Rays in The Heating Acts. These regulations specify requirements related to limitations of use, shielding and safety design requirements, control and interlock systems, warning devices, operating procedures, radiation monitoring, and calibration of medical accelerators

  12. Accelerator technology program. Progress report, July-December 1980

    International Nuclear Information System (INIS)

    Knapp, E.A.; Jameson, R.A.

    1982-01-01

    The activities of Los Alamos National Laboratory's Accelerator Technology Division are discussed. This report covers the last six months of calendar 1980 and is organized around the Division's major projects. These projects reflect a wide variety of applications and sponsors. The major technological innovations promoted by the Pion Generator for Medical Irradiation (PIGMI) program have been developed; accelerator technologies relevant to the design of a medically practical PIGMI have been identified. A new group in AT Division deals with microwave and magnet studies; we describe the status of some of their projects. We discuss the prototype gyrocon, which has been completed, and the development of the radio-frequency quadrupole linear accelerator, which continues to stimulate interest for many possible applications. One section of this report briefly describes the results of a design study for an electron beam ion source that is ideally suited as an injector for a heavy ion linac; another section reports on a turbine engine test facility that will expose operating turbine engines to simulated maneuver forces. In other sections we discuss various activities: the Fusion Materials Irradiation Test program, the free-electron laser program, the racetrack microtron project, the Proton Storage ring, and H - ion sources and injectors

  13. Program completion of a web-based tailored lifestyle intervention for adults: differences between a sequential and a simultaneous approach.

    Science.gov (United States)

    Schulz, Daniela N; Schneider, Francine; de Vries, Hein; van Osch, Liesbeth A D M; van Nierop, Peter W M; Kremers, Stef P J

    2012-03-08

    Unhealthy lifestyle behaviors often co-occur and are related to chronic diseases. One effective method to change multiple lifestyle behaviors is web-based computer tailoring. Dropout from Internet interventions, however, is rather high, and it is challenging to retain participants in web-based tailored programs, especially programs targeting multiple behaviors. To date, it is unknown how much information people can handle in one session while taking part in a multiple behavior change intervention, which could be presented either sequentially (one behavior at a time) or simultaneously (all behaviors at once). The first objective was to compare dropout rates of 2 computer-tailored interventions: a sequential and a simultaneous strategy. The second objective was to assess which personal characteristics are associated with completion rates of the 2 interventions. Using an RCT design, demographics, health status, physical activity, vegetable consumption, fruit consumption, alcohol intake, and smoking were self-assessed through web-based questionnaires among 3473 adults, recruited through Regional Health Authorities in the Netherlands in the autumn of 2009. First, a health risk appraisal was offered, indicating whether respondents were meeting the 5 national health guidelines. Second, psychosocial determinants of the lifestyle behaviors were assessed and personal advice was provided, about one or more lifestyle behaviors. Our findings indicate a high non-completion rate for both types of intervention (71.0%; n = 2167), with more incompletes in the simultaneous intervention (77.1%; n = 1169) than in the sequential intervention (65.0%; n = 998). In both conditions, discontinuation was predicted by a lower age (sequential condition: OR = 1.04; P simultaneous condition: OR = 1.04; P sequential condition: OR = 0.86; P = .01; CI = 0.76-0.97; simultaneous condition: OR = 0.49; P sequential intervention, being male (OR = 1.27; P = .04; CI = 1.01-1.59) also predicted dropout

  14. Effects of a Mathematics Cognitive Acceleration Program on Student Achievement and Motivation

    Science.gov (United States)

    Finau, Teukava; Treagust, David F.; Won, Mihye; Chandrasegaran, A. L.

    2018-01-01

    This paper presents the effects of a cognitive acceleration program in mathematics classes on Tongan students' achievements, motivation and self-regulation. Cognitive Acceleration in Mathematics Education (CAME) is a program developed at King's College and implemented worldwide with the aim of improving students' thinking skills, mathematics…

  15. A suppression hierarchy among competing motor programs drives sequential grooming in Drosophila.

    Science.gov (United States)

    Seeds, Andrew M; Ravbar, Primoz; Chung, Phuong; Hampel, Stefanie; Midgley, Frank M; Mensh, Brett D; Simpson, Julie H

    2014-08-19

    Motor sequences are formed through the serial execution of different movements, but how nervous systems implement this process remains largely unknown. We determined the organizational principles governing how dirty fruit flies groom their bodies with sequential movements. Using genetically targeted activation of neural subsets, we drove distinct motor programs that clean individual body parts. This enabled competition experiments revealing that the motor programs are organized into a suppression hierarchy; motor programs that occur first suppress those that occur later. Cleaning one body part reduces the sensory drive to its motor program, which relieves suppression of the next movement, allowing the grooming sequence to progress down the hierarchy. A model featuring independently evoked cleaning movements activated in parallel, but selected serially through hierarchical suppression, was successful in reproducing the grooming sequence. This provides the first example of an innate motor sequence implemented by the prevailing model for generating human action sequences. Copyright © 2014, Seeds et al.

  16. The high energy accelerator program in Japan

    International Nuclear Information System (INIS)

    Ozaki, S.

    1987-01-01

    The author observes that in order to survey the intentions of Japanese high energy physicists and to make a recommendation to the High Energy Committee on future plans for high energy physics in Japan, including accelerators after TRISTAN, international collaboration projects and non-accelerator physics, a subcommittee of fifteen members is formed. The committee recommendation reads: A) For a new energy frontier, 1. Immediate initiation of R/D efforts for an e/sup +/e/sup -/ linear collider of TeV class, constructs a possible home-based facility, 2. Promotes international collaborative experiments using the SSC for the hadron sector, B) As projects of immediate concern: 1. The energy of the TRISTAN main ring increases further makes a possible low energy, high luminosity e/sup +/e/sup -/ collider operation in the TRISTAN complex, 2. The intensity of the 12 GeV PS at KEK increases, 3. Experiments in non-accelerator particle physics are promoted. In this contribution, the current status of the TRISTAN project and some of the R/D program on accelerator technology are reported

  17. Guide to accelerator physics program SYNCH: VAX version 1987.2

    International Nuclear Information System (INIS)

    Parsa, Z.; Courant, E.

    1987-01-01

    This guide is written to accommodate users of Accelerator Physics Data Base BNLDAG::DUAO:[PARSA1]. It describes the contents of the on line Accelerator Physics data base DUAO:[PARSA1.SYNCH]. SYNCH is a computer program used for the design and analysis of synchrotrons, storage rings and beamlines

  18. Evaluating an accelerated nursing program: a dashboard for diversity.

    Science.gov (United States)

    Schmidt, Bonnie J; MacWilliams, Brent R

    2015-01-01

    Diversity is a topic of increasing attention in higher education and the nursing workforce. Experts have called for a nursing workforce that mirrors the population it serves. Students in nursing programs in the United States do not reflect our country's diverse population; therefore, much work is needed before that goal can be reached. Diversity cannot be successfully achieved in nursing education without inclusion and attention to quality. The Inclusive Excellence framework can be used by nurse educators to promote inclusion, diversity, and excellence. In this framework, excellence and diversity are linked in an intentional metric-driven process. Accelerated programs offer a possible venue to promote diversity, and one accelerated program is examined using a set of metrics and a dashboard approach commonly used in business settings. Several recommendations were made for future assessment, interventions, and monitoring. Nurse educators are called to examine and adopt a diversity dashboard in all nursing programs. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Accelerator Technology Program. Progress report, January-June 1980

    International Nuclear Information System (INIS)

    Knapp, E.A.; Jameson, R.A.

    1980-03-01

    The activities of Los Alamos Scientific Laboratory's (LASL) Accelerator Technology (AT) Division during the first six months of calendar 1980 are discussed. This report is organized around major projects of the Division, reflecting a wide variety of applications and sponsors. The first section summarizes progress on the Proton Storage Ring to be located between LAMPF and the LASL Pulsed Neutron Research facility, followed by a section on the gyrocon, a new type of high-power, high-efficiency radio-frequency (rf) amplifier. The third section discusses the racetrack microtron being developed jointly by AT Division and the National Bureau of Standards; the fourth section concerns the free-electron studies. The fifth section covers the radio-frequency quadrupole linear accelerator, a new concept for the acceleration of low-velocity particles; this section is followed by a section discussing heavy ion fusion accelerator development. The next section reports activities in the Fusion Materials Irradiation Test program, a collaborative effort with the Hanford Engineering Development Laboratory. The final section deals first with development of H - ion sources and injectors, then with accelerator instrumentation and beam dynamics

  20. Computer programs in accelerator physics

    International Nuclear Information System (INIS)

    Keil, E.

    1984-01-01

    Three areas of accelerator physics are discussed in which computer programs have been applied with much success: i) single-particle beam dynamics in circular machines, i.e. the design and matching of machine lattices; ii) computations of electromagnetic fields in RF cavities and similar objects, useful for the design of RF cavities and for the calculation of wake fields; iii) simulation of betatron and synchrotron oscillations in a machine with non-linear elements, e.g. sextupoles, and of bunch lengthening due to longitudinal wake fields. (orig.)

  1. Experience and development program for the I.V. Kurchatov Atomic Energy Institute electron linear accelerator

    International Nuclear Information System (INIS)

    Aref'ev, A.V.; Blokhov, M.V.; Gerasimov, V.F.

    1981-01-01

    A program of physical investigations and the corresponding requirements to accelerated beam parameters are discussed in brief. The state and working capacity of separate units and the accelerator as a whole for the 8-year operating period are analyzed. The aim and principal program points of linear electron accelerator modernization are defined. The program of accelerator modernization assumes: electron beam energy increase up to 100-120 MeV; mounting of three additional accelerating sections; clystron efficiency increase; development of a highly reliable modulator; stabilized power supply sources; a system of synchronous start-up; a focusing system; a beam separation system and etc [ru

  2. Program for Plasma-Based Concepts for Future High Energy Accelerators

    International Nuclear Information System (INIS)

    Katsouleas, Thomas C.; Muggli, Patric

    2003-01-01

    OAK B204 Program for Plasma-Based Concepts for Future High Energy Accelerators. The progress made under this program in the period since November 15, 2002 is reflected in this report. The main activities for this period were to conduct the first run of the E-164 high-gradient wakefield experiment at SLAC, to prepare for run 2 and to continue our collaborative effort with CERN to model electron cloud interactions in circular accelerators. Each of these is described. Also attached to this report are papers that were prepared or appeared during this period

  3. Programming Cell Adhesion for On-Chip Sequential Boolean Logic Functions.

    Science.gov (United States)

    Qu, Xiangmeng; Wang, Shaopeng; Ge, Zhilei; Wang, Jianbang; Yao, Guangbao; Li, Jiang; Zuo, Xiaolei; Shi, Jiye; Song, Shiping; Wang, Lihua; Li, Li; Pei, Hao; Fan, Chunhai

    2017-08-02

    Programmable remodelling of cell surfaces enables high-precision regulation of cell behavior. In this work, we developed in vitro constructed DNA-based chemical reaction networks (CRNs) to program on-chip cell adhesion. We found that the RGD-functionalized DNA CRNs are entirely noninvasive when interfaced with the fluidic mosaic membrane of living cells. DNA toehold with different lengths could tunably alter the release kinetics of cells, which shows rapid release in minutes with the use of a 6-base toehold. We further demonstrated the realization of Boolean logic functions by using DNA strand displacement reactions, which include multi-input and sequential cell logic gates (AND, OR, XOR, and AND-OR). This study provides a highly generic tool for self-organization of biological systems.

  4. 76 FR 50224 - Medicare Program; Accountable Care Organization Accelerated Development Learning Sessions; Center...

    Science.gov (United States)

    2011-08-12

    ...] Medicare Program; Accountable Care Organization Accelerated Development Learning Sessions; Center for... (CMS). This two-day training session is the second Accelerated Development Learning Session (ADLS.... Through Accelerated Development Learning Sessions (ADLS), the Innovation Center will test whether...

  5. Object oriented programming interfaces for accelerator control

    International Nuclear Information System (INIS)

    Hoff, L.T.

    1997-01-01

    Several years ago, the AGS controls group was given the task of developing software for the RHIC accelerator. Like the AGS, the RHIC control system needs to control and monitor equipment distributed around a relatively large geographic area. A local area network connects this equipment to a collection of UNIX workstations in a central control room. Similar software had been developed for the AGS about a decade earlier, but isn't well suited for RHIC use for a number of reasons. Rather than adapt the AGS software for RHIC use, the controls group opted to start with a clean slate. To develop software that would address the shortcomings of the AGS software, while preserving the useful features that evolved through years of use. A current trend in control system design is to provide an object oriented programming interface for application developers. This talk will discuss important aspects and features of object oriented application programming interfaces (APIs) for accelerator control systems, and explore why such interfaces are becoming the norm

  6. Accelerator technology program. Status report, July-December 1982

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1984-05-01

    Major projects of the Los Alamos National Laboratory's Accelerator Technology Division are discussed, covering activities that occurred during the last six months of calendar 1982. The first sections report highlights in beam dynamics, accelerator inertial fusion, radio-frequency structure development, the racetrack microtron, CERN high-energy physics experiment NA-12, and high-flux radiographic linac study. Next we report on selected proton Storage Ring activities that have made significant progress during this reporting period, followed by an update on the free electron laser. The Fusion Materials Irradiation Test Facility work is discussed next, then progress on the klystron development project and on the gyrocon project. The activities of the newly formed Theory and Simulation Group are outlined. The last section covers activities concerning the accelerator test stand for the neutral particle beam program

  7. 76 FR 66931 - Medicare Program; Accountable Care Organization Accelerated Development Learning Sessions; Center...

    Science.gov (United States)

    2011-10-28

    ...] Medicare Program; Accountable Care Organization Accelerated Development Learning Sessions; Center for... Services (CMS). This two-day training session is the third and final Accelerated Development Learning... the quality of care for beneficiaries. Through Accelerated Development Learning Sessions (ADLS), the...

  8. CHEF: an Interactive program for accelerator optics

    International Nuclear Information System (INIS)

    Michelotti, Leo; Ostiguy, Jean-Francois

    2005-01-01

    We report the current status and our plans for the completion of CHEF, an interactive application for performing optics calculations in accelerator physics. CHEF uses high level graphical user interfaces to facilitate the exploitation of lower level tools incorporated into a hierarchy of C++ class libraries, making them usable by those not familiar with C++ programming

  9. The accelerated site technology deployment program presents the segmented gate system

    International Nuclear Information System (INIS)

    Patteson, Raymond; Maynor, Doug; Callan, Connie

    2000-01-01

    The Department of Energy (DOE) is working to accelerate the acceptance and application of innovative technologies that improve the way the nation manages its environmental remediation problems. The DOE Office of Science and Technology established the Accelerated Site Technology Deployment Program (ASTD) to help accelerate the acceptance and implementation of new and innovative soil and ground water remediation technologies. Coordinated by the Department of Energy's Idaho Office, the ASTD Program reduces many of the classic barriers to the deployment of new technologies by involving government, industry, and regulatory agencies in the assessment, implementation, and validation of innovative technologies. The paper uses the example of the Segmented Gate System (SGS) to illustrate how the ASTD program works. The SGS was used to cost effectively separate clean and contaminated soil for four different radionuclides: plutonium, uranium, thorium, and cesium. Based on those results, it has been proposed to use the SGS at seven other DOE sites across the country

  10. Polarized proton acceleration program at the AGS and RHIC

    International Nuclear Information System (INIS)

    Lee, Y.Y.

    1995-01-01

    Presented is an overview of the program for acceleration of polarized protons in the AGS and their injection into the RHIC collider. The problem of depolarizing resonances in strong focusing circulator accelerators is discussed. The intrinsic resonances are jumped over by the fast tune jump, and a partial Siberian Snake is used to compensate for over forty imperfection resonances in the AGS. Two sets of full Siberian Snake and spin rotators will be employed in RHIC

  11. Construction of computational program of aging in insulating materials for searching reversed sequential test conditions to give damage equivalent to simultaneous exposure of heat and radiation

    International Nuclear Information System (INIS)

    Fuse, Norikazu; Homma, Hiroya; Okamoto, Tatsuki

    2013-01-01

    Two consecutive numerical calculations on degradation of polymeric insulations under thermal and radiation environment are carried out to simulate so-called reversal sequential acceleration test. The aim of the calculation is to search testing conditions which provide material damage equivalent to the case of simultaneous exposure of heat and radiation. At least following four parameters are needed to be considered in the sequential method; dose rate and exposure time in radiation, as well as temperature and aging time in heating. The present paper discusses the handling of these parameters and shows some trial calculation results. (author)

  12. Further Developments on Optimum Structural Design Using MSC/Nastran and Sequential Quadratic Programming

    DEFF Research Database (Denmark)

    Holzleitner, Ludwig

    1996-01-01

    , here the shape of two dimensional parts with different thickness areas will be optimized. As in the previos paper, a methodology for structural optimization using the commercial finite element package MSC/NASTRAN for structural analysis is described. Three different methods for design sensitivity......This work is closely connected to the paper: K.G. MAHMOUD, H.W. ENGL and HOLZLEITNER: "OPTIMUM STRUCTURAL DESIGN USING MSC/NASTRAN AND SEQUENTIAL QUADRATIC PROGRAMMING", Computers & Structures, Vol. 52, No. 3, pp. 437-447, (1994). In contrast to that paper, where thickness optimization is described...

  13. Accelerator technology program. Status report, October 1984-March 1985

    International Nuclear Information System (INIS)

    Jameson, R.A.; Schriber, S.O.

    1986-04-01

    Activities of the racetrack-microtron development programs are highlighted, one of which is being done in collaboration with the National Bureau of Standards and the other with the University of Illinois; the BEAR (Beam Experiment Aboard Rocket) project; work in beam dynamics; the proposed LAMPF II accelerator; and the Proton Storage Ring. Discussed next is radio-frequency and microwave technology, followed by activities in accelerator theory and simulation, and free-electron laser technology. The report concludes with a listing of papers published during this reporting period

  14. Computing sequential equilibria for two-player games

    DEFF Research Database (Denmark)

    Miltersen, Peter Bro

    2006-01-01

    Koller, Megiddo and von Stengel showed how to efficiently compute minimax strategies for two-player extensive-form zero-sum games with imperfect information but perfect recall using linear programming and avoiding conversion to normal form. Their algorithm has been used by AI researchers...... for constructing prescriptive strategies for concrete, often fairly large games. Koller and Pfeffer pointed out that the strategies obtained by the algorithm are not necessarily sequentially rational and that this deficiency is often problematic for the practical applications. We show how to remove this deficiency...... by modifying the linear programs constructed by Koller, Megiddo and von Stengel so that pairs of strategies forming a sequential equilibrium are computed. In particular, we show that a sequential equilibrium for a two-player zero-sum game with imperfect information but perfect recall can be found in polynomial...

  15. Computing Sequential Equilibria for Two-Player Games

    DEFF Research Database (Denmark)

    Miltersen, Peter Bro; Sørensen, Troels Bjerre

    2006-01-01

    Koller, Megiddo and von Stengel showed how to efficiently compute minimax strategies for two-player extensive-form zero-sum games with imperfect information but perfect recall using linear programming and avoiding conversion to normal form. Koller and Pfeffer pointed out that the strategies...... obtained by the algorithm are not necessarily sequentially rational and that this deficiency is often problematic for the practical applications. We show how to remove this deficiency by modifying the linear programs constructed by Koller, Megiddo and von Stengel so that pairs of strategies forming...... a sequential equilibrium are computed. In particular, we show that a sequential equilibrium for a two-player zero-sum game with imperfect information but perfect recall can be found in polynomial time. In addition, the equilibrium we find is normal-form perfect. Our technique generalizes to general-sum games...

  16. Stressors Experienced by Nursing Students Enrolled in Baccalaureate Second Degree Accelerated Registered Nursing Programs

    Science.gov (United States)

    Bell, Charlene

    2017-01-01

    A mounting concern throughout the country is a current and growing nursing shortage. In order to meet the growing demand of nurses, many colleges have created baccalaureate second degree accelerated registered nursing programs. Stressors, experienced by nursing students in these accelerated programs, may affect their retention. A deeper…

  17. A sequential quadratic programming algorithm using an incomplete solution of the subproblem

    Energy Technology Data Exchange (ETDEWEB)

    Murray, W. [Stanford Univ., CA (United States). Systems Optimization Lab.; Prieto, F.J. [Universidad `Carlos III` de Madrid (Spain). Dept. de Estadistica y Econometria

    1993-05-01

    We analyze sequential quadratic programming (SQP) methods to solve nonlinear constrained optimization problems that are more flexible in their definition than standard SQP methods. The type of flexibility introduced is motivated by the necessity to deviate from the standard approach when solving large problems. Specifically we no longer require a minimizer of the QP subproblem to be determined or particular Lagrange multiplier estimates to be used. Our main focus is on an SQP algorithm that uses a particular augmented Lagrangian merit function. New results are derived for this algorithm under weaker conditions than previously assumed; in particular, it is not assumed that the iterates lie on a compact set.

  18. Effect of Exercise Program Speed, Agility, and Quickness (SAQ) in Improving Speed, Agility, and Acceleration

    Science.gov (United States)

    Azmi, K.; Kusnanik, N. W.

    2018-01-01

    This study aimed to analyze the effect of speed, agility and quickness training program to increase in speed, agility and acceleration. This study was conducted at 26 soccer players and divided into 2 groups with 13 players each group. Group 1 was given SAQ training program, and Group 2 conventional training program for 8 weeks. This study used a quantitative approach with quasi-experimental method. The design of this study used a matching-only design. Data was collected by testing 30-meter sprint (speed), agility t-test (agility), and run 10 meters (acceleration) during the pretest and posttest. Furthermore, the data was analyzed using paired sample t-test and independent t-test. The results showed: that there was a significant effect of speed, agility and quickness training program in improving in speed, agility and acceleration. In summary, it can be concluded that the speed, agility and quickness training program can improve the speed, agility and acceleration of the soccer players.

  19. From coach to colleague: adjusting pedagogical approaches and attitudes in accelerated nursing programs.

    Science.gov (United States)

    Bowie, Bonnie H; Carr, Katherine Camacho

    2013-01-01

    Accelerated nursing programs are an innovative approach to training nurses and advanced practice nurses that are growing steadily in number and popularity. Although there is ample evidence to show that these programs have good outcomes, acceptance by both faculty and nurses in the community remains low. This article gives a description of the accelerated nursing student, which provides some insight as to why this student is both a challenge and a joy to mentor. In addition, an overview of pedagogical approaches that may be helpful in teaching this bright group of accelerated nursing students is provided. Accelerated nursing students enrich the nursing profession with the myriad of skills and varied backgrounds they bring to nursing. As professionals, mentors, and educators, we need to not only embrace accelerated students but also be advocates and mentors for them as they assimilate into our profession. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Comprehensive review of an accelerated nursing program: a quality improvement project.

    Science.gov (United States)

    Nugent, Elinor; LaRocco, Susan

    2014-01-01

    Accelerated second-degree programs are designed to provide entry into baccalaureate nursing program for people who have achieved bachelor's degree in another field. These programs were often designed to respond to nursing shortages at local and national levels. Programs commonly use a cohort model and move students through an intensive structure combining classroom and clinical requirement with a 2-year period. The accelerated second-degree nursing program, Accelerated Entry Level to Nursing program at our small liberal arts college, was considered to be successful. The program had excellent graduation rates and National Council Licensure Examination for Registered Nurses pass rates, indicating that the program was preparing the graduate to thrive in the practice setting. The program had been in existence for more than 7 years, with highly competitive admissions and high student satisfaction. The objective of this study was to provide a quality improvement assessment process to capture quantitative and qualitative information about the graduates. This information would be used to inform our own nursing education department and would provide metrics and information for nurse leaders regarding the rigor of these programs and the potential of graduates. Continuous quality improvement is a vital component in nursing education as well as in the clinical setting. With this in mind, a comprehensive review was undertaken by the nursing faculty during the eighth year of the highly successful accelerated nursing program in a small liberal arts college. This quality improvement project was designed to review existing metrics and to collect additional data through survey and focus groups in order to capture experiences of the program graduates. Graduates of the accelerated program from 2005 to 2011 were included in this study. Faculty who teach in the program participated in focus groups. From 2005 to 2011, there have been a total of 196 graduates in 8 cohorts; 194 surveys

  1. Accelerator Technology Program. Status report, October 1983-March 1984

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1985-01-01

    This report covers major projects in the Accelerator Technology (AT) Division of the Los Alamos National Laboratory. The first sections highlight activities related to beam dynamics, inertial fusion, structure development, the racetrack microtron, and the CERN high-energy physics experiment NA-12. Discussed next is the Fusion Materials Irradiation Test Facility, followed by a summary of progress on the Proton Storage Ring and activities of the Theory and Simulation Group. The report concludes with a discussion of the H- accelerator program and a listing of papers published by AT-Division personnel during this reporting period

  2. Exploiting first-class arrays in Fortran for accelerator programming

    International Nuclear Information System (INIS)

    Rasmussen, Craig E.; Weseloh, Wayne N.; Robey, Robert W.; Sottile, Matthew J.; Quinlan, Daniel; Overbey, Jeffrey

    2010-01-01

    Emerging architectures for high performance computing often are well suited to a data parallel programming model. This paper presents a simple programming methodology based on existing languages and compiler tools that allows programmers to take advantage of these systems. We will work with the array features of Fortran 90 to show how this infrequently exploited, standardized language feature is easily transformed to lower level accelerator code. Our transformations are based on a mapping from Fortran 90 to C++ code with OpenCL extensions. The sheer complexity of programming for clusters of many or multi-core processors with tens of millions threads of execution make the simplicity of the data parallel model attractive. Furthermore, the increasing complexity of todays applications (especially when convolved with the increasing complexity of the hardware) and the need for portability across hardware architectures make a higher-level and simpler programming model like data parallel attractive. The goal of this work has been to exploit source-to-source transformations that allow programmers to develop and maintain programs at a high-level of abstraction, without coding to a specific hardware architecture. Furthermore these transformations allow multiple hardware architectures to be targeted without changing the high-level source. It also removes the necessity for application programmers to understand details of the accelerator architecture or to know OpenCL.

  3. A solution for automatic parallelization of sequential assembly code

    Directory of Open Access Journals (Sweden)

    Kovačević Đorđe

    2013-01-01

    Full Text Available Since modern multicore processors can execute existing sequential programs only on a single core, there is a strong need for automatic parallelization of program code. Relying on existing algorithms, this paper describes one new software solution tool for parallelization of sequential assembly code. The main goal of this paper is to develop the parallelizator which reads sequential assembler code and at the output provides parallelized code for MIPS processor with multiple cores. The idea is the following: the parser translates assembler input file to program objects suitable for further processing. After that the static single assignment is done. Based on the data flow graph, the parallelization algorithm separates instructions on different cores. Once sequential code is parallelized by the parallelization algorithm, registers are allocated with the algorithm for linear allocation, and the result at the end of the program is distributed assembler code on each of the cores. In the paper we evaluate the speedup of the matrix multiplication example, which was processed by the parallelizator of assembly code. The result is almost linear speedup of code execution, which increases with the number of cores. The speed up on the two cores is 1.99, while on 16 cores the speed up is 13.88.

  4. Sequential and simultaneous choices: testing the diet selection and sequential choice models.

    Science.gov (United States)

    Freidin, Esteban; Aw, Justine; Kacelnik, Alex

    2009-03-01

    We investigate simultaneous and sequential choices in starlings, using Charnov's Diet Choice Model (DCM) and Shapiro, Siller and Kacelnik's Sequential Choice Model (SCM) to integrate function and mechanism. During a training phase, starlings encountered one food-related option per trial (A, B or R) in random sequence and with equal probability. A and B delivered food rewards after programmed delays (shorter for A), while R ('rejection') moved directly to the next trial without reward. In this phase we measured latencies to respond. In a later, choice, phase, birds encountered the pairs A-B, A-R and B-R, the first implementing a simultaneous choice and the second and third sequential choices. The DCM predicts when R should be chosen to maximize intake rate, and SCM uses latencies of the training phase to predict choices between any pair of options in the choice phase. The predictions of both models coincided, and both successfully predicted the birds' preferences. The DCM does not deal with partial preferences, while the SCM does, and experimental results were strongly correlated to this model's predictions. We believe that the SCM may expose a very general mechanism of animal choice, and that its wider domain of success reflects the greater ecological significance of sequential over simultaneous choices.

  5. Southern California Regional Technology Acceleration Program

    Energy Technology Data Exchange (ETDEWEB)

    Ochoa, Rosibel [Univ. of California, San Diego, CA (United States). Jacobs School of Engineering; Rasochova, Lada [Univ. of California, San Diego, CA (United States). Rady School of Management

    2014-09-30

    UC San Diego and San Diego State University are partnering to address these deficiencies in the renewable energy space in the greater San Diego region, accelerating the movement of clean energy innovation from the university laboratory into the marketplace, building on the proven model of the William J. von Liebig Center’s (vLC’s) Proof of Concept (POC) program and virtualizing the effort to enable a more inclusive environment for energy innovation and expansion of the number of clean energy start-ups and/or technology licenses in greater California.

  6. Prospects for an Accelerator Program in Mexico Focused on Photon Science

    Energy Technology Data Exchange (ETDEWEB)

    Carlos Hernandez-Garcia, Mauro Napsuciale

    2011-05-01

    Recent interest in developing an accelerator-based light source in Mexico has driven several actions by the Division of Particles and Fields in Mexico, and by the electron accelerator community in the United States. We report on activities over the past two years that are very encouraging and offer a variety of possibilities to start the development of an accelerator program in Mexico. A suggested path towards this goal that would eventually lead to building, commissioning and operating a third or fourth generation light source will also be presented

  7. Using student satisfaction data to evaluate a new online accelerated nursing education program.

    Science.gov (United States)

    Gazza, Elizabeth A; Matthias, April

    2016-10-01

    As increasing numbers of students enroll in online education, institutions of higher education are responsible for delivering quality online courses and programs. Agencies that accredit institutions and programs require evidence of program quality, including student satisfaction. A large state university in the Southeastern United States transitioned an online nursing education degree completion, or Registered Nurse-to-Bachelor of Science in Nursing, program to an online accelerated format in order to meet the needs of working nurses and ultimately, increase the number of nurses prepared at the baccalaureate level. This article describes a descriptive, cross-sectional study that evaluated the effectiveness of the new online accelerated program using the quality indicator of student satisfaction. Ninety-one (32%) of the 284 students who were enrolled or had been enrolled in a course within the online accelerated degree completion program between fall 2013 session 1 and summer 2014 session participated in the study. The electronic Noel-Levitz Priorities Survey for Online Learners™ was used to measure student satisfaction with the program and associated services. Results provided insight into the students' satisfaction with the new program format and served as the basis for an interdepartmental program enhancement plan aimed at maintaining and enhancing student satisfaction and overall program quality. Findings indicated that measuring and evaluating student satisfaction can provide valuable information about the effectiveness of an online program. Recommendations for using the measurement tool in online program planning and studying student satisfaction in relation to retention and program completion were identified. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. A Music Program for Training Head Start Teachers Using a Sequential, Cognitive, Developmental Process with Pre-school Children.

    Science.gov (United States)

    Brodhecker, Shirley G.

    This practicum report addresses the need to supply Head Start teachers with: (1) specific preschool music objectives; (2) a sequential preschool developmental program in music to match the child's cognitive level; (3) how to choose instructional material to encourage specific basic school readiness skills; and (4) workshops to accomplish these…

  9. Framework for sequential approximate optimization

    NARCIS (Netherlands)

    Jacobs, J.H.; Etman, L.F.P.; Keulen, van F.; Rooda, J.E.

    2004-01-01

    An object-oriented framework for Sequential Approximate Optimization (SAO) isproposed. The framework aims to provide an open environment for thespecification and implementation of SAO strategies. The framework is based onthe Python programming language and contains a toolbox of Python

  10. NIST Accelerator Facilities And Programs In Support Of Industrial Radiation Research

    International Nuclear Information System (INIS)

    Bateman, F.B.; Desrosiers, M.F.; Hudson, L.T.; Coursey, B.M.; Bergstrom, P.M. Jr.; Seltzer, S.M.

    2003-01-01

    NIST's Ionizing Radiation Division maintains and operates three electron accelerators used in a number of applications including waste treatment and sterilization, radiation hardness testing, detector calibrations and materials modification studies. These facilities serve a large number of governmental, academic and industrial users as well as an active intramural research program. They include a 500 kV cascaded-rectifier accelerator, a 2.5 MV electron Van de Graaff accelerator and a 7 to 32 MeV electron linac, supplying beams ranging in energy from a few keV up to 32 MeV. In response to the recent anthrax incident, NIST along with the US Postal Service and the Armed Forces Radiobiology Research Institute (AFRRI) are working to develop protocols and testing procedures for the USPS mail sanitization program. NIST facilities and personnel are being employed in a series of quality-assurance measurements for both electron- and photon-beam sanitization. These include computational modeling, dose verification and VOC (volatile organic compounds) testing using megavoltage electron and photon sources

  11. C-quence: a tool for analyzing qualitative sequential data.

    Science.gov (United States)

    Duncan, Starkey; Collier, Nicholson T

    2002-02-01

    C-quence is a software application that matches sequential patterns of qualitative data specified by the user and calculates the rate of occurrence of these patterns in a data set. Although it was designed to facilitate analyses of face-to-face interaction, it is applicable to any data set involving categorical data and sequential information. C-quence queries are constructed using a graphical user interface. The program does not limit the complexity of the sequential patterns specified by the user.

  12. Accelerator technology program. Progress report, July-December 1981

    International Nuclear Information System (INIS)

    Knapp, E.A.; Jameson, R.A.

    1982-08-01

    We report on the major projects of the Los Alamos National Laboratory's Accelerator Technology Division during the last 6 months of calendar year 1981. We have continued work on the radio-frequency quadrupole linear accelerator; we are doing studies of octupole focusing. We have completed the design study on an unusual electron-linear radiographic machine that could obtain x rays of turbine engines operating under simulated flight-maneuver conditions on a centrifuge. In September we completed the 5-y PIon Generator for Medical Irradiation (PIGMI) program to develop the concept and technology for an accelerator-based facility to treat cancer in a hospital environment. The design and construction package for the site, building, and utilities for the Fusion Materials Irradiation Test (FMIT) facility has been completed, and we have begun to concentrate on tests of the rf power equipment and on the design, procurement, and installation of the 2-MeV proto-type accelerator. The Proton Storage Ring project has continued to mature. The main effort on the racetrack microtron (RTM) has been on the design and construction of various components for the demonstration RTM. On the gyrocon radio-frequency generator project, the gyrocon was rebuilt with a new electron gun and new water-cooled gun-focus coil; these new components have performed well. We have initiated a project to produce a klystron analysis code that will be useful in reducing the electrical-energy demand for accelerators. A free-electron laser amplifier experiment to test the performance of a tapered wiggler at high optical power has been successfully completed

  13. R&D PROPOSAL FOR THE NATIONAL MUON ACCELERATOR PROGRAM

    Energy Technology Data Exchange (ETDEWEB)

    Muon Accelerator Program; Zisman, Michael S.; Geer, Stephen

    2010-02-24

    This document contains a description of a multi-year national R&D program aimed at completing a Design Feasibility Study (DFS) for a Muon Collider and, with international participation, a Reference Design Report (RDR) for a muon-based Neutrino Factory. It also includes the supporting component development and experimental efforts that will inform the design studies and permit an initial down-selection of candidate technologies for the ionization cooling and acceleration systems. We intend to carry out this plan with participants from the host national laboratory (Fermilab), those from collaborating U.S. national laboratories (ANL, BNL, Jlab, LBNL, and SNAL), and those from a number of other U.S. laboratories, universities, and SBIR companies. The R&D program that we propose will provide the HEP community with detailed information on future facilities based on intense beams of muons--the Muon Collider and the Neutrino Factory. We believe that these facilities offer the promise of extraordinary physics capabilities. The Muon Collider presents a powerful option to explore the energy frontier and the Neutrino Factory gives the opportunity to perform the most sensitive neutrino oscillation experiments possible, while also opening expanded avenues for the study of new physics in the neutrino sector. The synergy between the two facilities presents the opportunity for an extremely broad physics program and a unique pathway in accelerator facilities. Our work will give clear answers to the questions of expected capabilities and performance of these muon-based facilities, and will provide defensible ranges for their cost. This information, together with the physics insights gained from the next-generation neutrino and LHC experiments, will allow the HEP community to make well-informed decisions regarding the optimal choice of new facilities. We believe that this work is a critical part of any broad strategic program in accelerator R&D and, as the P5 panel has recently

  14. Overview of graduate training program of John Adams Institute for Accelerator Science

    Science.gov (United States)

    Seryi, Andrei

    The John Adams Institute for Accelerator Science is a center of excellence in the UK for advanced and novel accelerator technology, providing expertise, research, development and training in accelerator techniques, and promoting advanced accelerator applications in science and society. We work in JAI on design of novel light sources upgrades of 3-rd generation and novel FELs, on plasma acceleration and its application to industrial and medical fields, on novel energy recovery compact linacs and advanced beam diagnostics, and many other projects. The JAI is based on three universities - University of Oxford, Imperial College London and Royal Holloway University of London. Every year 6 to 10 accelerators science experts, trained via research on cutting edge projects, defend their PhD thesis in JAI partner universities. In this presentation we will overview the research and in particular the highly successful graduate training program in JAI.

  15. Progress report on the accelerator production of tritium materials irradiation program

    International Nuclear Information System (INIS)

    Maloy, S.A.; Sommer, W.F.; Brown, R.D.; Roberts, J.E.

    1997-01-01

    The Accelerator Production of Tritium (APT) project is developing an accelerator and a spoliation neutron source capable of producing tritium through neutron capture on He-3. A high atomic weight target is used to produce neutrons that are then multiplied and moderated in a blanket prior to capture. Materials used in the target and blanket region of an APT facility will be subjected to several different and mixed particle radiation environments; high energy protons (1-2 GeV), protons in the 20 MeV range, high energy neutrons, and low energy neutrons, depending on position in the target and blanket. Flux levels exceed 10 14 /cm 2 s in some areas. The APT project is sponsoring an irradiation damage effects program that will generate the first data-base for materials exposed to high energy particles typical of spallation neutron sources. The program includes a number of candidate materials in small specimen and model component form and uses the Los Alamos Spallation Radiation Effects Facility (LASREF) at the 800 MeV, Los Alamos Neutron Science Center (LANSCE) accelerator

  16. Ultimate-gradient accelerators physics and prospects

    CERN Document Server

    Skrinsky, Aleksander Nikolayevich

    1995-01-01

    As introduction, the needs and ways for ultimate acceleration gradients are discussed briefly. The Plasma Wake Field Acceleration is analized in the most important details. The structure of specific plasma oscillations and "high energy driver beam SP-plasma" interaction is presented, including computer simulation of the process. Some pratical ways to introduce the necessary mm-scale bunching in driver beam and to arrange sequential energy multiplication are dicussed. The influence of accelerating beam particle - plasma binary collisions is considered, also. As applications of PWFA, the use of proton super-colliders beams (LHC and Future SC) to drive the "multi particle types" accelerator, and the arrangements for the electron-positron TeV range collider are discussed.

  17. Accelerated Leach Test(s) Program. Annual report

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Fuhrmann, M.; Colombo, P.

    1985-09-01

    This report summarizes the work performed for the Accelerated Leach Test(s) Program at Brookhaven National Laboratory in Fiscal Year 1985 under the sponsorship of the US Department of Energy's Low-Level Waste Management Program (LLWMP). Programmatic activities were concentrated in three areas, as listed and described in the following paragraphs. (1) A literature survey of reported leaching mechanisms, available mathematical models and factors that affect leaching of LLW forms has been compiled. Mechanisms which have been identified include diffusion, dissolution, ion exchange, corrosion and surface effects. Available mathematical models are based on diffusion as the predominant mechanism. Although numerous factors that affect leaching have been identified, they have been conveniently categorized as factors related to the entire leaching system, to the leachant or to the waste form. A report has been published on the results of this literature survey. (2) A computerized data base of LLW leaching data and mathematical models is being developed. The data are being used for model evaluation by curve fitting and statistical analysis according to standard procedures of statistical quality control. (3) Long-term tests on portland cement, bitumen and vinyl ester-styrene (VES) polymer waste forms are underway which are designed to identify and evaluate factors that accelerate leaching without changing the mechanisms. Results on the effect of temperature on leachability indicate that the leach rates of cement and VES waste forms increase with increasing temperature, whereas, the leach rate of bitumen is little affected

  18. Fermilab's SC Accelerator Magnet Program for Future U.S. HEP Facilities

    International Nuclear Information System (INIS)

    Lamm, Michael; Zlobin, Alexander

    2010-01-01

    The invention of SC accelerator magnets in the 1970s opened wide the possibilities for advancing the energy frontier of particle accelerators, while limiting the machine circumference and reducing their energy consumption. The successful development of SC accelerator magnets based on NbTi superconductor have made possible a proton-antiproton collider (Tevatron) at Fermilab, an electron-proton collider (HERA) at DESY, a relativistic heavy ion collider (RHIC) at BNL and recently a proton-proton collider (LHC) at CERN. Further technological innovations and inventions are required as the US HEP looks forward towards the post-LHC energy or/and intensity frontiers. A strong, goal oriented national SC accelerator magnet program must take on this challenge to provide a strong base for the future of HEP in the U.S. The results and experience obtained by Fermilab during the past 30 years will allow us to play a leadership role in the SC accelerator magnet development in the U.S., in particular, focusing on magnets for a Muon Collider/Neutrino Factory (1)-(2). In this paper, we summarize the required Muon Collider magnet needs and challenges, summarize the technology advances in the Fermilab accelerator magnet development over the past few years, and present and discuss our vision and long-term plans for these Fermilab-supported accelerator initiatives.

  19. BEAMPATH: a program library for beam dynamics simulation in linear accelerators

    International Nuclear Information System (INIS)

    Batygin, Y.K.

    1992-01-01

    A structured programming technique was used to develop software for space charge dominated beams investigation in linear accelerators. The method includes hierarchical program design using program independent modules and a flexible combination of modules to provide a most effective version of structure for every specific case of simulation. A modular program BEAMPATH was developed for 2D and 3D particle-in-cell simulation of beam dynamics in a structure containing RF gaps, radio-frequency quadrupoles (RFQ), multipole lenses, waveguides, bending magnets and solenoids. (author) 5 refs.; 2 figs

  20. The composite sequential clustering technique for analysis of multispectral scanner data

    Science.gov (United States)

    Su, M. Y.

    1972-01-01

    The clustering technique consists of two parts: (1) a sequential statistical clustering which is essentially a sequential variance analysis, and (2) a generalized K-means clustering. In this composite clustering technique, the output of (1) is a set of initial clusters which are input to (2) for further improvement by an iterative scheme. This unsupervised composite technique was employed for automatic classification of two sets of remote multispectral earth resource observations. The classification accuracy by the unsupervised technique is found to be comparable to that by traditional supervised maximum likelihood classification techniques. The mathematical algorithms for the composite sequential clustering program and a detailed computer program description with job setup are given.

  1. Accelerated Combinatorial High Throughput Star Polymer Synthesis via a Rapid One-Pot Sequential Aqueous RAFT (rosa-RAFT) Polymerization Scheme.

    Science.gov (United States)

    Cosson, Steffen; Danial, Maarten; Saint-Amans, Julien Rosselgong; Cooper-White, Justin J

    2017-04-01

    Advanced polymerization methodologies, such as reversible addition-fragmentation transfer (RAFT), allow unprecedented control over star polymer composition, topology, and functionality. However, using RAFT to produce high throughput (HTP) combinatorial star polymer libraries remains, to date, impracticable due to several technical limitations. Herein, the methodology "rapid one-pot sequential aqueous RAFT" or "rosa-RAFT," in which well-defined homo-, copolymer, and mikto-arm star polymers can be prepared in very low to medium reaction volumes (50 µL to 2 mL) via an "arm-first" approach in air within minutes, is reported. Due to the high conversion of a variety of acrylamide/acrylate monomers achieved during each successive short reaction step (each taking 3 min), the requirement for intermediary purification is avoided, drastically facilitating and accelerating the star synthesis process. The presented methodology enables RAFT to be applied to HTP polymeric bio/nanomaterials discovery pipelines, in which hundreds of complex polymeric formulations can be rapidly produced, screened, and scaled up for assessment in a wide range of applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A mathematical programming approach for sequential clustering of dynamic networks

    Science.gov (United States)

    Silva, Jonathan C.; Bennett, Laura; Papageorgiou, Lazaros G.; Tsoka, Sophia

    2016-02-01

    A common analysis performed on dynamic networks is community structure detection, a challenging problem that aims to track the temporal evolution of network modules. An emerging area in this field is evolutionary clustering, where the community structure of a network snapshot is identified by taking into account both its current state as well as previous time points. Based on this concept, we have developed a mixed integer non-linear programming (MINLP) model, SeqMod, that sequentially clusters each snapshot of a dynamic network. The modularity metric is used to determine the quality of community structure of the current snapshot and the historical cost is accounted for by optimising the number of node pairs co-clustered at the previous time point that remain so in the current snapshot partition. Our method is tested on social networks of interactions among high school students, college students and members of the Brazilian Congress. We show that, for an adequate parameter setting, our algorithm detects the classes that these students belong more accurately than partitioning each time step individually or by partitioning the aggregated snapshots. Our method also detects drastic discontinuities in interaction patterns across network snapshots. Finally, we present comparative results with similar community detection methods for time-dependent networks from the literature. Overall, we illustrate the applicability of mathematical programming as a flexible, adaptable and systematic approach for these community detection problems. Contribution to the Topical Issue "Temporal Network Theory and Applications", edited by Petter Holme.

  3. A new method of measuring gravitational acceleration in an undergraduate laboratory program

    Science.gov (United States)

    Wang, Qiaochu; Wang, Chang; Xiao, Yunhuan; Schulte, Jurgen; Shi, Qingfan

    2018-01-01

    This paper presents a high accuracy method to measure gravitational acceleration in an undergraduate laboratory program. The experiment is based on water in a cylindrical vessel rotating about its vertical axis at a constant speed. The water surface forms a paraboloid whose focal length is related to rotational period and gravitational acceleration. This experimental setup avoids classical source errors in determining the local value of gravitational acceleration, so prevalent in the common simple pendulum and inclined plane experiments. The presented method combines multiple physics concepts such as kinematics, classical mechanics and geometric optics, offering the opportunity for lateral as well as project-based learning.

  4. [Advanced accelerator R and D program]. Final report

    International Nuclear Information System (INIS)

    1997-01-01

    This proposal requests funding for a 3-year renewal of the DOE advanced accelerator R and D (AARD) program at Texas A and M University. The program to date has focused on the development of the gigatron, a compact high-efficiency microwave driver for future linear colliders. The author reports results and progress in that project, and plans to bring it to a milestone and conclusion by mid-1995. He proposes to initiate a second project, the development of a new technology for ultra-high field superconducting magnets for future hadron colliders. This project builds upon two magnet designs which he has introduced during the past year, which have the potential for a dramatic extension of the achievable field strength for both dipoles and quadrupoles

  5. Unified accelerator libraries

    International Nuclear Information System (INIS)

    Malitsky, Nikolay; Talman, Richard

    1997-01-01

    A 'Universal Accelerator Libraries' (UAL) environment is described. Its purpose is to facilitate program modularity and inter-program and inter-process communication among heterogeneous programs. The goal ultimately is to facilitate model-based control of accelerators

  6. R and D PROPOSAL FOR THE NATIONAL MUON ACCELERATOR PROGRAM

    International Nuclear Information System (INIS)

    Zisman, Michael S.; Geer, Stephen

    2010-01-01

    This document contains a description of a multi-year national R and amp;D program aimed at completing a Design Feasibility Study (DFS) for a Muon Collider and, with international participation, a Reference Design Report (RDR) for a muon-based Neutrino Factory. It also includes the supporting component development and experimental efforts that will inform the design studies and permit an initial down-selection of candidate technologies for the ionization cooling and acceleration systems. We intend to carry out this plan with participants from the host national laboratory (Fermilab), those from collaborating U.S. national laboratories (ANL, BNL, Jlab, LBNL, and SNAL), and those from a number of other U.S. laboratories, universities, and SBIR companies. The R and D program that we propose will provide the HEP community with detailed information on future facilities based on intense beams of muons--the Muon Collider and the Neutrino Factory. We believe that these facilities offer the promise of extraordinary physics capabilities. The Muon Collider presents a powerful option to explore the energy frontier and the Neutrino Factory gives the opportunity to perform the most sensitive neutrino oscillation experiments possible, while also opening expanded avenues for the study of new physics in the neutrino sector. The synergy between the two facilities presents the opportunity for an extremely broad physics program and a unique pathway in accelerator facilities. Our work will give clear answers to the questions of expected capabilities and performance of these muon-based facilities, and will provide defensible ranges for their cost. This information, together with the physics insights gained from the next-generation neutrino and LHC experiments, will allow the HEP community to make well-informed decisions regarding the optimal choice of new facilities. We believe that this work is a critical part of any broad strategic program in accelerator R and D and, as the P5 panel has

  7. Accelerated test program

    Science.gov (United States)

    Ford, F. E.; Harkness, J. M.

    1977-01-01

    A brief discussion on the accelerated testing of batteries is given. The statistical analysis and the various aspects of the modeling that was done and the results attained from the model are also briefly discussed.

  8. Characteristics of Teachers Nominated for an Accelerated Principal Preparation Program

    Science.gov (United States)

    Rios, Steve J.; Reyes-Guerra, Daniel

    2012-01-01

    This article reports the initial evaluation results of a new accelerated, job-embedded principal preparation program funded by a Race to the Top Grant (U.S. Department of Education, 2012a) in Florida. Descriptive statistics, t-tests, and chi-square analyses were used to describe the characteristics of a group of potential applicants nominated to…

  9. Acceleration of the nodal program FERM

    International Nuclear Information System (INIS)

    Nakata, H.

    1985-01-01

    Acceleration of the nodal FERM was tried by three acceleration schemes. Results of the calculations showed the best acceleration with the Tchebyshev method where the savings in the computing time were of the order of 50%. Acceleration with the Assymptotic Source Extrapoltation Method and with the Coarse-Mesh Rebalancing Method did not result in any improvement on the global computational time, although a reduction in the number of outer iterations was observed. (Author) [pt

  10. Sequential computation of elementary modes and minimal cut sets in genome-scale metabolic networks using alternate integer linear programming

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hyun-Seob; Goldberg, Noam; Mahajan, Ashutosh; Ramkrishna, Doraiswami

    2017-03-27

    Elementary (flux) modes (EMs) have served as a valuable tool for investigating structural and functional properties of metabolic networks. Identification of the full set of EMs in genome-scale networks remains challenging due to combinatorial explosion of EMs in complex networks. It is often, however, that only a small subset of relevant EMs needs to be known, for which optimization-based sequential computation is a useful alternative. Most of the currently available methods along this line are based on the iterative use of mixed integer linear programming (MILP), the effectiveness of which significantly deteriorates as the number of iterations builds up. To alleviate the computational burden associated with the MILP implementation, we here present a novel optimization algorithm termed alternate integer linear programming (AILP). Results: Our algorithm was designed to iteratively solve a pair of integer programming (IP) and linear programming (LP) to compute EMs in a sequential manner. In each step, the IP identifies a minimal subset of reactions, the deletion of which disables all previously identified EMs. Thus, a subsequent LP solution subject to this reaction deletion constraint becomes a distinct EM. In cases where no feasible LP solution is available, IP-derived reaction deletion sets represent minimal cut sets (MCSs). Despite the additional computation of MCSs, AILP achieved significant time reduction in computing EMs by orders of magnitude. The proposed AILP algorithm not only offers a computational advantage in the EM analysis of genome-scale networks, but also improves the understanding of the linkage between EMs and MCSs.

  11. LIAR -- A new program for the modeling and simulation of linear accelerators with high gradients and small emittances

    International Nuclear Information System (INIS)

    Assmann, R.; Adolphsen, C.; Bane, K.; Raubenheimer, T.O.; Siemann, R.; Thompson, K.

    1996-09-01

    Linear accelerators are the central components of the proposed next generation of linear colliders. They need to provide acceleration of up to 750 GeV per beam while maintaining very small normalized emittances. Standard simulation programs, mainly developed for storage rings, do not meet the specific requirements for high energy linear accelerators. The authors present a new program LIAR (LInear Accelerator Research code) that includes wakefield effects, a 4D coupled beam description, specific optimization algorithms and other advanced features. Its modular structure allows to use and to extend it easily for different purposes. They present examples of simulations for SLC and NLC

  12. Implementation of a quality control program for a 6 MeV linear photon accelerator

    International Nuclear Information System (INIS)

    Berdaky, Mafalda F.; Caldas, Linda V.E.

    2001-01-01

    This paper describes the operational characteristics of the final process of implementation of a quality control program using routine mechanical and radiation tests. The quality control program was performed during 35 months and demonstrated the excellent stability of this accelerator. (author)

  13. Real sequential evaluation of materials balance data with the computer program PROSA

    International Nuclear Information System (INIS)

    Bicking, U.; Golly, W.; Seifert, R.

    1991-01-01

    Material accountancy is an important tool for international nuclear safeguards. The aim is to detect a possible loss of material timely and with high probability. In this context, a computer program called PROSA (Program for Sequential Analysis of NRTA data) was developed at the Karlsruhe Nuclear Research Center. PROSA is a statistical tool to decide on the basis of statistical considerations whether or not in a given sequence of material balances a loss of material might have occurred. The evaluation of the material balance data (MUF values) is carried out with statistical test procedures. In the present PROSA version 4.0 three tests, Page's test, CUMUF test and GEMUF test are applied at a time. These three test procedures are the result of several years of research and are supposed to be the most promising ones with respect to the detection probability of possible losses of material as well as to the timeliness of such a detection. PROSA version 4.0 is a user-friendly, menudriven computer program which is suitable for routine field application. Data input - that means MUF values and measurement model - can be performed either by diskette or by key-enter. The output consists of an information whether or not an alarm is indicated. This information can be displayed either numerically or graphically. Therefore, a comfortable graphical output utility is attached to PROSA version 4.0. In this presentation the theoretical concepts implemented in PROSA will be explained. Furthermore, the functioning of the program will be presented and the performance of PROSA will be demonstrated using balance data of a real reprocessing campaign. (J.P.N.)

  14. RAMPRF: A program for synchronous acceleration

    International Nuclear Information System (INIS)

    Furman, M.A.

    1991-05-01

    We describe a family of standard FORTRAN programs that calculate bucket-related quantities as a function of time during acceleration, assuming it is adiabatic. The members of the family are distinguished by the type of input: One family member takes energy and total peak voltage as a function of time; another takes momentum and bucket area as a function of time, etc. The input is in free-format tabular form. The output is in standard ASCII form, in multi-column tables and x-y listings appropriate for plotting. Bunch-related quantities, such as energy spread and space-charge tune spread, are also calculated assuming that the bunches have a specified longitudinal emittance, and are small and matched to the bucket. Sample excitation curves for the SSC's low energy booster are presented. 4 refs., 2 figs

  15. Virtual gap dielectric wall accelerator

    Science.gov (United States)

    Caporaso, George James; Chen, Yu-Jiuan; Nelson, Scott; Sullivan, Jim; Hawkins, Steven A

    2013-11-05

    A virtual, moving accelerating gap is formed along an insulating tube in a dielectric wall accelerator (DWA) by locally controlling the conductivity of the tube. Localized voltage concentration is thus achieved by sequential activation of a variable resistive tube or stalk down the axis of an inductive voltage adder, producing a "virtual" traveling wave along the tube. The tube conductivity can be controlled at a desired location, which can be moved at a desired rate, by light illumination, or by photoconductive switches, or by other means. As a result, an impressed voltage along the tube appears predominantly over a local region, the virtual gap. By making the length of the tube large in comparison to the virtual gap length, the effective gain of the accelerator can be made very large.

  16. Effects of a combined parent-student alcohol prevention program on intermediate factors and adolescents' drinking behavior: A sequential mediation model.

    Science.gov (United States)

    Koning, Ina M; Maric, Marija; MacKinnon, David; Vollebergh, Wilma A M

    2015-08-01

    Previous work revealed that the combined parent-student alcohol prevention program (PAS) effectively postponed alcohol initiation through its hypothesized intermediate factors: increase in strict parental rule setting and adolescents' self-control (Koning, van den Eijnden, Verdurmen, Engels, & Vollebergh, 2011). This study examines whether the parental strictness precedes an increase in adolescents' self-control by testing a sequential mediation model. A cluster randomized trial including 3,245 Dutch early adolescents (M age = 12.68, SD = 0.50) and their parents randomized over 4 conditions: (1) parent intervention, (2) student intervention, (3) combined intervention, and (4) control group. Outcome measure was amount of weekly drinking measured at age 12 to 15; baseline assessment (T0) and 3 follow-up assessments (T1-T3). Main effects of the combined and parent intervention on weekly drinking at T3 were found. The effect of the combined intervention on weekly drinking (T3) was mediated via an increase in strict rule setting (T1) and adolescents' subsequent self-control (T2). In addition, the indirect effect of the combined intervention via rule setting (T1) was significant. No reciprocal sequential mediation (self-control at T1 prior to rules at T2) was found. The current study is 1 of the few studies reporting sequential mediation effects of youth intervention outcomes. It underscores the need of involving parents in youth alcohol prevention programs, and the need to target both parents and adolescents, so that change in parents' behavior enables change in their offspring. (c) 2015 APA, all rights reserved).

  17. R&D PROPOSAL FOR THE NATIONAL MUON ACCELERATOR PROGRAM

    OpenAIRE

    Zisman, Michael S.

    2011-01-01

    This document contains a description of a multi-year national R&D program aimed at completing a Design Feasibility Study (DFS) for a Muon Collider and, with international participation, a Reference Design Report (RDR) for a muon-based Neutrino Factory. It also includes the supporting component development and experimental efforts that will inform the design studies and permit an initial down-selection of candidate technologies for the ionization cooling and acceleration systems. We intend to ...

  18. Magnet R and D for the US LHC Accelerator Research Program (LARP)

    International Nuclear Information System (INIS)

    Gourlay, S.A.; Ambrosio, G.; Andreev, N.; Anerella, M.; Barzi, E.; Bossert, R.; Caspi, S.; Dietderich, D.R.; Ferracin, P.; Gupta, R.; Ghosh, A.; Hafalia, A.R.; Hannaford, C.R.; Harrison, M.; Kashikhin, V.S.; Kashikhin, V.V.; Lietzke, A.F.; Mattafirri, S.; McInturff, A.D.; Nobrega, F.; Novitsky, I.; Sabbi, G.L.; Schmazle, J.; Stanek, R.; Turrioni, D.; Wanderer, P.; Yamada, R.; Zlobin, A.V.

    2006-01-01

    In 2004, the US DOE established the LHC Accelerator Research Program (LARP) with the goal of developing a technology base for future upgrades of the LHC. The focus of the magnet program, which is a collaboration of three US laboratories, BNL, FNAL and LBNL, is on development of high gradient quadrupoles using Nb 3 Sn superconductor. Other program components address issues regarding magnet design, radiation-hard materials, long magnet scale-up, quench protection, fabrication techniques and conductor and cable R and D. This paper presents an overall view of the program with emphasis on the current quadrupole project and outlines the long-term goals of the program

  19. Sequential dependencies in magnitude scaling of loudness

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Jesteadt, Walt

    2013-01-01

    Ten normally hearing listeners used a programmable sone-potentiometer knob to adjust the level of a 1000-Hz sinusoid to match the loudness of numbers presented to them in a magnitude production task. Three different power-law exponents (0.15, 0.30, and 0.60) and a log-law with equal steps in d......B were used to program the sone-potentiometer. The knob settings systematically influenced the form of the loudness function. Time series analysis was used to assess the sequential dependencies in the data, which increased with increasing exponent and were greatest for the log-law. It would be possible......, therefore, to choose knob properties that minimized these dependencies. When the sequential dependencies were removed from the data, the slope of the loudness functions did not change, but the variability decreased. Sequential dependencies were only present when the level of the tone on the previous trial...

  20. Research of Virtual Accelerator Control System

    Institute of Scientific and Technical Information of China (English)

    DongJinmei; YuanYoujin; ZhengJianhua

    2003-01-01

    A Virtual Accelerator is a computer process which simulates behavior of beam in an accelerator and responds to the accelerator control program under development in a same way as an actual accelerator. To realize Virtual Accelerator, control system should provide the same program interface to top layer Application Control Program, it can make 'Real Accelerator' and 'Virtual Accelerator'use the same GUI, so control system should have a layer to hide hardware details, Application Control Program access control devices through logical name but not through coded hardware address. Without this layer, it is difficult to develop application program which can access both 'Virtual' and 'Real' Accelerators using same program interfaces. For this reason, we can create CSR Runtime Database which allows application program to access hardware devices and data on a simulation process in a unified way. A device 'is represented as a collection of records in CSR Runtime Database. A control program on host computer can access devices in the system only through names of record fields, called channel.

  1. Current heavy particle medical accelerator programs in Japan

    International Nuclear Information System (INIS)

    Kawachi, K.

    1987-01-01

    The first clinical trial of proton radiotherapy in Japan started at National Institute of Radiological Sciences (NIRS) in 1979. The proton which is provided from the NIRS medical cyclotron, has an energy of 70 MeV, and has been used for only superficial or short range tumor therapy. Recently, the cyclotron has been raised the energy up to 90 MeV and a vertical treatment line of protons has been completed in the basement of the cyclotron building. In 1983, Particle Radiation Medical Science Center (PARMS) of the University of Tsukuba started to treat patients with 250 MeV proton beam. The Institute of Physical and Chemical Research (IPCR) has a plan to construct a heavy ion biomedical irradiation facility in the Ring (Separate Sector) Cyclotron building. The facility will be completed in 1989 and will be used for proton and helium ion therapy. Recently, several hospitals have proposed to construct the dedicated proton therapy facilities. The National Cancer Center of Japan, and the PARMS of the University of Tsukuba have taken active parts in such projects. At present time, there is a step to make a decision of the type of accelerators. Another program is a construction of the NIRS Heavy Particle Medical Accelerator which is possible to provide Helium to Argon ions for therapy. The paper describes the accelerators for proton therapy and for heavy ion therapy in some detail

  2. A dynamic regrouping based sequential dynamic programming algorithm for unit commitment of combined heat and power systems

    DEFF Research Database (Denmark)

    Rong, Aiying; Hakonen, Henri; Lahdelma, Risto

    2009-01-01

    efficiency of the plants. We introduce in this paper the DRDP-RSC algorithm, which is a dynamic regrouping based dynamic programming (DP) algorithm based on linear relaxation of the ON/OFF states of the units, sequential commitment of units in small groups. Relaxed states of the plants are used to reduce...... the dimension of the UC problem and dynamic regrouping is used to improve the solution quality. Numerical results based on real-life data sets show that this algorithm is efficient and optimal or near-optimal solutions with very small optimality gap are obtained....

  3. DOE's Innovative Treatment Remediation Demonstration Program accelerating the implementation of innovative technologies

    International Nuclear Information System (INIS)

    Hightower, M.

    1995-01-01

    A program to help accelerate the adoption and implementation of new and innovative remediation technologies has been initiated by the Department of Energy's (DOE) Environmental Restoration Program Office (EM40). Developed as a Public-Private Partnership program in cooperation with the US Environmental Protection Agency's (EPA) Technology Innovation Office (TIO) and coordinated by Sandia National Laboratories, the Innovative Treatment Remediation Demonstration (ITRD) Program attempts to reduce many of the classic barriers to the use of new technologies by involving government, industry, and regulatory agencies in the assessment, implementation, and validation of innovative technologies. In this program, DOE facilities work cooperatively with EPA, industry, national laboratories, and state and federal regulatory agencies to establish remediation demonstrations using applicable innovative technologies at their sites. Selected innovative technologies are used to remediate small, one to two acre, sites to generate the full-scale and real-world operating, treatment performance, and cost data needed to validate these technologies and gain acceptance by industry and regulatory agencies, thus accelerating their use nationwide. Each ITRD project developed at a DOE site is designed to address a typical soil or groundwater contamination issue facing both DOE and industry. This includes sites with volatile organic compound (VOC), semi-VOC, heavy metal, explosive residue, and complex or multiple constituent contamination. Projects are presently underway at three DOE facilities, while additional projects are under consideration for initiation in FY96 at several additional DOE sites. A brief overview of the ITRD Program, program plans, and the status and progress of existing ITRD projects are reviewed in this paper

  4. Accelerating Sequential Gaussian Simulation with a constant path

    Science.gov (United States)

    Nussbaumer, Raphaël; Mariethoz, Grégoire; Gravey, Mathieu; Gloaguen, Erwan; Holliger, Klaus

    2018-03-01

    Sequential Gaussian Simulation (SGS) is a stochastic simulation technique commonly employed for generating realizations of Gaussian random fields. Arguably, the main limitation of this technique is the high computational cost associated with determining the kriging weights. This problem is compounded by the fact that often many realizations are required to allow for an adequate uncertainty assessment. A seemingly simple way to address this problem is to keep the same simulation path for all realizations. This results in identical neighbourhood configurations and hence the kriging weights only need to be determined once and can then be re-used in all subsequent realizations. This approach is generally not recommended because it is expected to result in correlation between the realizations. Here, we challenge this common preconception and make the case for the use of a constant path approach in SGS by systematically evaluating the associated benefits and limitations. We present a detailed implementation, particularly regarding parallelization and memory requirements. Extensive numerical tests demonstrate that using a constant path allows for substantial computational gains with very limited loss of simulation accuracy. This is especially the case for a constant multi-grid path. The computational savings can be used to increase the neighbourhood size, thus allowing for a better reproduction of the spatial statistics. The outcome of this study is a recommendation for an optimal implementation of SGS that maximizes accurate reproduction of the covariance structure as well as computational efficiency.

  5. Students' Perceptions of Long-Functioning Cooperative Teams in Accelerated Adult Degree Programs

    Science.gov (United States)

    Favor, Judy

    2012-01-01

    This study examined 718 adult students' perceptions of long-functioning cooperative study teams in accelerated associate's, bachelor's, and master's business degree programs. Six factors were examined: attraction toward team, alignment of performance expectations, intrateam conflict, workload sharing, preference for teamwork, and impact on…

  6. A versatile program for the calculation of linear accelerator room shielding.

    Science.gov (United States)

    Hassan, Zeinab El-Taher; Farag, Nehad M; Elshemey, Wael M

    2018-03-22

    This work aims at designing a computer program to calculate the necessary amount of shielding for a given or proposed linear accelerator room design in radiotherapy. The program (Shield Calculation in Radiotherapy, SCR) has been developed using Microsoft Visual Basic. It applies the treatment room shielding calculations of NCRP report no. 151 to calculate proper shielding thicknesses for a given linear accelerator treatment room design. The program is composed of six main user-friendly interfaces. The first enables the user to upload their choice of treatment room design and to measure the distances required for shielding calculations. The second interface enables the user to calculate the primary barrier thickness in case of three-dimensional conventional radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and total body irradiation (TBI). The third interface calculates the required secondary barrier thickness due to both scattered and leakage radiation. The fourth and fifth interfaces provide a means to calculate the photon dose equivalent for low and high energy radiation, respectively, in door and maze areas. The sixth interface enables the user to calculate the skyshine radiation for photons and neutrons. The SCR program has been successfully validated, precisely reproducing all of the calculated examples presented in NCRP report no. 151 in a simple and fast manner. Moreover, it easily performed the same calculations for a test design that was also calculated manually, and produced the same results. The program includes a new and important feature that is the ability to calculate required treatment room thickness in case of IMRT and TBI. It is characterised by simplicity, precision, data saving, printing and retrieval, in addition to providing a means for uploading and testing any proposed treatment room shielding design. The SCR program provides comprehensive, simple, fast and accurate room shielding calculations in radiotherapy.

  7. Multipactor Physics, Acceleration, and Breakdown in Dielectric-Loaded Accelerating Structures

    International Nuclear Information System (INIS)

    Fischer, Richard P.; Gold, Steven H.

    2016-01-01

    The objective of this 3-year program is to study the physics issues associated with rf acceleration in dielectric-loaded accelerating (DLA) structures, with a focus on the key issue of multipactor loading, which has been found to cause very significant rf power loss in DLA structures whenever the rf pulsewidth exceeds the multipactor risetime (~10 ns). The experiments are carried out in the X-band magnicon laboratory at the Naval Research Laboratory (NRL) in collaboration with Argonne National Laboratory (ANL) and Euclid Techlabs LLC, who develop the test structures with support from the DoE SBIR program. There are two main elements in the research program: (1) high-power tests of DLA structures using the magnicon output (20 MW @11.4 GHz), and (2) tests of electron acceleration in DLA structures using relativistic electrons from a compact X-band accelerator. The work during this period has focused on a study of the use of an axial magnetic field to suppress multipactor in DLA structures, with several new high power tests carried out at NRL, and on preparation of the accelerator for the electron acceleration experiments.

  8. Sequential computation of elementary modes and minimal cut sets in genome-scale metabolic networks using alternate integer linear programming.

    Science.gov (United States)

    Song, Hyun-Seob; Goldberg, Noam; Mahajan, Ashutosh; Ramkrishna, Doraiswami

    2017-08-01

    Elementary (flux) modes (EMs) have served as a valuable tool for investigating structural and functional properties of metabolic networks. Identification of the full set of EMs in genome-scale networks remains challenging due to combinatorial explosion of EMs in complex networks. It is often, however, that only a small subset of relevant EMs needs to be known, for which optimization-based sequential computation is a useful alternative. Most of the currently available methods along this line are based on the iterative use of mixed integer linear programming (MILP), the effectiveness of which significantly deteriorates as the number of iterations builds up. To alleviate the computational burden associated with the MILP implementation, we here present a novel optimization algorithm termed alternate integer linear programming (AILP). Our algorithm was designed to iteratively solve a pair of integer programming (IP) and linear programming (LP) to compute EMs in a sequential manner. In each step, the IP identifies a minimal subset of reactions, the deletion of which disables all previously identified EMs. Thus, a subsequent LP solution subject to this reaction deletion constraint becomes a distinct EM. In cases where no feasible LP solution is available, IP-derived reaction deletion sets represent minimal cut sets (MCSs). Despite the additional computation of MCSs, AILP achieved significant time reduction in computing EMs by orders of magnitude. The proposed AILP algorithm not only offers a computational advantage in the EM analysis of genome-scale networks, but also improves the understanding of the linkage between EMs and MCSs. The software is implemented in Matlab, and is provided as supplementary information . hyunseob.song@pnnl.gov. Supplementary data are available at Bioinformatics online. Published by Oxford University Press 2017. This work is written by US Government employees and are in the public domain in the US.

  9. What good are actions? Accelerating learning using learned action priors

    CSIR Research Space (South Africa)

    Rosman, Benjamin S

    2012-11-01

    Full Text Available The computational complexity of learning in sequential decision problems grows exponentially with the number of actions available to the agent at each state. We present a method for accelerating this process by learning action priors that express...

  10. Status report of pelletron accelerator and ECR based heavy ion accelerator programme

    International Nuclear Information System (INIS)

    Gupta, A.K.

    2015-01-01

    The BARC-TIFR Pelletron Accelerator is completing twenty seven years of round-the-clock operation, serving diverse users from institutions within and outside DAE. Over the years, various developmental activities and application oriented programs have been initiated at Pelletron Accelerator Facility, resulting into enhanced utilization of the accelerator. We have also been pursuing an ECR based heavy ion accelerator programme under XII th Plan, consisting of an 18 GHz superconducting ECR (Electron Cyclotron Resonance) ion source and a room temperature RFQ (Radio Frequency Quadrupole) followed by low and high beta superconducting niobium resonator cavities. This talk will provide the current status of Pelletron Accelerator and the progress made towards the ECR based heavy ion accelerator program at BARC. (author)

  11. An experimental program for collective acceleration of ions using intense relativistic electron beams

    International Nuclear Information System (INIS)

    Vijayan, T.; Raychowdhury, P.; Iyengar, S.K.

    1992-01-01

    A program of collective ion acceleration using intense relativistic electron beam (IREB) of 0.25-1MeV, 6-80kA, 60ns on the Kilo Ampere Linear Injector (KALI) systems to accelerate light and heavy ions to high energies approaching GeV with currents over tens of amperes, is envisaged in this report. The accelerator will make use of the intense space-charge field of electron beam in vacuum for accelerating ions which are injected into it. For ion injection, various alternatives, such as, localized gas puff, dielectric insert, laser plasma, etc. have been considered as present and long-term objectives. Among the variety of diagnostic methods chosen for characterizing the accelerated ions include range-energy in foil, CR-39 track detector, nuclear activation technique and time-of-flight for energy and species determination; ion Faraday cup for current measurement; and Thomson parabola analyzer for determining the post-acceleration charge-state. In the proposed MAHAKALI collective accelerator, protons of energy over 10 MeV and higher charge state metal ions around a GeV are predicted using a REB of 1MeV, 30kA, 60ns from KALI-5000. In present experiments using KALI-200 with REB parameters of 250keV, 60kA, 80ns, protons over a MeV and carbon and fluorine ions respectively for 12MeV and 16MeV in significant currents have been accelerated. (author). 35 refs., figs., tabs

  12. Refinement of Parallel and Reactive Programs

    OpenAIRE

    Back, R. J. R.

    1992-01-01

    We show how to apply the refinement calculus to stepwise refinement of parallel and reactive programs. We use action systems as our basic program model. Action systems are sequential programs which can be implemented in a parallel fashion. Hence refinement calculus methods, originally developed for sequential programs, carry over to the derivation of parallel programs. Refinement of reactive programs is handled by data refinement techniques originally developed for the sequential refinement c...

  13. Sequential optimization of matrix chain multiplication relative to different cost functions

    KAUST Repository

    Chikalov, Igor; Hussain, Shahid; Moshkov, Mikhail

    2011-01-01

    In this paper, we present a methodology to optimize matrix chain multiplication sequentially relative to different cost functions such as total number of scalar multiplications, communication overhead in a multiprocessor environment, etc. For n matrices our optimization procedure requires O(n 3) arithmetic operations per one cost function. This work is done in the framework of a dynamic programming extension that allows sequential optimization relative to different criteria. © 2011 Springer-Verlag Berlin Heidelberg.

  14. Programs, interfaces and components

    NARCIS (Netherlands)

    Bergstra, J.A.; Loots, M.E.

    The jump instruction is considered essential for an adequate theoretical understanding of imperative sequential programming. Using atomic actions and tests as a basis we outline an algebra of programs, denoted PGA, which captures the crux of sequential programming. PGA provides an ontology for

  15. Sequential Power-Dependence Theory

    NARCIS (Netherlands)

    Buskens, Vincent; Rijt, Arnout van de

    2008-01-01

    Existing methods for predicting resource divisions in laboratory exchange networks do not take into account the sequential nature of the experimental setting. We extend network exchange theory by considering sequential exchange. We prove that Sequential Power-Dependence Theory—unlike

  16. Accelerator Technology Division annual report, FY 1991

    International Nuclear Information System (INIS)

    1992-04-01

    This report discusses the following programs: The Ground Test Accelerator Program; APLE Free-Electron Laser Program; Accelerator Transmutation of Waste; JAERI, OMEGA Project, and Intense Neutron Source for Materials Testing; Advanced Free-Electron Laser Initiative; Superconducting Super Collider; The High-Power Microwave Program; Φ Factory Collaboration; Neutral Particle Beam Power System Highlights; Accelerator Physics and Special Projects; Magnetic Optics and Beam Diagnostics; Accelerator Design and Engineering; Radio-Frequency Technology; Free-Electron Laser Technology; Accelerator Controls and Automation; Very High-Power Microwave Sources and Effects; and GTA Installation, Commissioning, and Operations

  17. Breast conserving treatment for breast cancer: dosimetric comparison of sequential versus simultaneous integrated photon boost.

    Science.gov (United States)

    Van Parijs, Hilde; Reynders, Truus; Heuninckx, Karina; Verellen, Dirk; Storme, Guy; De Ridder, Mark

    2014-01-01

    Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P = 0.0001). There was less dose spilling to the ipsilateral breast outside the PTVboost (P = 0.04). The dose to the organs at risk (OAR) was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine.

  18. Influence of Sequential vs. Simultaneous Dual-Task Exercise Training on Cognitive Function in Older Adults.

    Science.gov (United States)

    Tait, Jamie L; Duckham, Rachel L; Milte, Catherine M; Main, Luana C; Daly, Robin M

    2017-01-01

    Emerging research indicates that exercise combined with cognitive training may improve cognitive function in older adults. Typically these programs have incorporated sequential training, where exercise and cognitive training are undertaken separately. However, simultaneous or dual-task training, where cognitive and/or motor training are performed simultaneously with exercise, may offer greater benefits. This review summary provides an overview of the effects of combined simultaneous vs. sequential training on cognitive function in older adults. Based on the available evidence, there are inconsistent findings with regard to the cognitive benefits of sequential training in comparison to cognitive or exercise training alone. In contrast, simultaneous training interventions, particularly multimodal exercise programs in combination with secondary tasks regulated by sensory cues, have significantly improved cognition in both healthy older and clinical populations. However, further research is needed to determine the optimal characteristics of a successful simultaneous training program for optimizing cognitive function in older people.

  19. Sequential nonadiabatic excitation of large molecules and ions driven by strong laser fields

    International Nuclear Information System (INIS)

    Markevitch, Alexei N.; Levis, Robert J.; Romanov, Dmitri A.; Smith, Stanley M.; Schlegel, H. Bernhard; Ivanov, Misha Yu.

    2004-01-01

    Electronic processes leading to dissociative ionization of polyatomic molecules in strong laser fields are investigated experimentally, theoretically, and numerically. Using time-of-flight ion mass spectroscopy, we study the dependence of fragmentation on laser intensity for a series of related molecules and report regular trends in this dependence on the size, symmetry, and electronic structure of a molecule. Based on these data, we develop a model of dissociative ionization of polyatomic molecules in intense laser fields. The model is built on three elements: (i) nonadiabatic population transfer from the ground electronic state to the excited-state manifold via a doorway (charge-transfer) transition; (ii) exponential enhancement of this transition by collective dynamic polarization of all electrons, and (iii) sequential energy deposition in both neutral molecules and resulting molecular ions. The sequential nonadiabatic excitation is accelerated by a counterintuitive increase of a large molecule's polarizability following its ionization. The generic theory of sequential nonadiabatic excitation forms a basis for quantitative description of various nonlinear processes in polyatomic molecules and ions in strong laser fields

  20. Automatic synthesis of sequential control schemes

    International Nuclear Information System (INIS)

    Klein, I.

    1993-01-01

    Of all hard- and software developed for industrial control purposes, the majority is devoted to sequential, or binary valued, control and only a minor part to classical linear control. Typically, the sequential parts of the controller are invoked during startup and shut-down to bring the system into its normal operating region and into some safe standby region, respectively. Despite its importance, fairly little theoretical research has been devoted to this area, and sequential control programs are therefore still created manually without much theoretical support to obtain a systematic approach. We propose a method to create sequential control programs automatically. The main ideas is to spend some effort off-line modelling the plant, and from this model generate the control strategy, that is the plan. The plant is modelled using action structures, thereby concentrating on the actions instead of the states of the plant. In general the planning problem shows exponential complexity in the number of state variables. However, by focusing on the actions, we can identify problem classes as well as algorithms such that the planning complexity is reduced to polynomial complexity. We prove that these algorithms are sound, i.e., the generated solution will solve the stated problem, and complete, i.e., if the algorithms fail, then no solution exists. The algorithms generate a plan as a set of actions and a partial order on this set specifying the execution order. The generated plant is proven to be minimal and maximally parallel. For a larger class of problems we propose a method to split the original problem into a number of simple problems that can each be solved using one of the presented algorithms. It is also shown how a plan can be translated into a GRAFCET chart, and to illustrate these ideas we have implemented a planing tool, i.e., a system that is able to automatically create control schemes. Such a tool can of course also be used on-line if it is fast enough. This

  1. The Italian R and D and industrial program for an accelerator driven system experimental plant

    International Nuclear Information System (INIS)

    Carta, M.; Gherardi, G.; Buono, S.; Cinotti, L.

    2001-01-01

    Accelerator Driven Systems (ADS), coupling an accelerator with a target and a sub-critical reactor, could simultaneously burn minor actinides and transmute long-lived fission products, while producing a consistent amount of electrical energy. A team of Italian R and D organizations and industries has set up a network of coordinated programs addressed to study the design issues of an 80 MW th Experimental Facility. The present memo focalizes the attention on some results obtained by the R and D activities and by the ongoing industrial short term activities aiming at the preparation of the proposed preliminary design, leaving the deal to define the details of the subsequent medium term activities to the expected common program in the European context. (author)

  2. Separation of left and right lungs using 3D information of sequential CT images and a guided dynamic programming algorithm

    Science.gov (United States)

    Park, Sang Cheol; Leader, Joseph Ken; Tan, Jun; Lee, Guee Sang; Kim, Soo Hyung; Na, In Seop; Zheng, Bin

    2011-01-01

    Objective this article presents a new computerized scheme that aims to accurately and robustly separate left and right lungs on CT examinations. Methods we developed and tested a method to separate the left and right lungs using sequential CT information and a guided dynamic programming algorithm using adaptively and automatically selected start point and end point with especially severe and multiple connections. Results the scheme successfully identified and separated all 827 connections on the total 4034 CT images in an independent testing dataset of CT examinations. The proposed scheme separated multiple connections regardless of their locations, and the guided dynamic programming algorithm reduced the computation time to approximately 4.6% in comparison with the traditional dynamic programming and avoided the permeation of the separation boundary into normal lung tissue. Conclusions The proposed method is able to robustly and accurately disconnect all connections between left and right lungs and the guided dynamic programming algorithm is able to remove redundant processing. PMID:21412104

  3. Wake field acceleration experiments

    International Nuclear Information System (INIS)

    Simpson, J.D.

    1988-01-01

    Where and how will wake field acceleration devices find use for other than, possibly, accelerators for high energy physics? I don't know that this can be responsibly answered at this time. What I can do is describe some recent results from an ongoing experimental program at Argonne which support the idea that wake field techniques and devices are potentially important for future accelerators. Perhaps this will spawn expanded interest and even new ideas for the use of this new technology. The Argonne program, and in particular the Advanced Accelerator Test Facility (AATF), has been reported in several fairly recent papers and reports. But because this is a substantially new audience for the subject, I will include a brief review of the program and the facility before describing experiments. 10 refs., 7 figs

  4. Optimization strategies based on sequential quadratic programming applied for a fermentation process for butanol production.

    Science.gov (United States)

    Pinto Mariano, Adriano; Bastos Borba Costa, Caliane; de Franceschi de Angelis, Dejanira; Maugeri Filho, Francisco; Pires Atala, Daniel Ibraim; Wolf Maciel, Maria Regina; Maciel Filho, Rubens

    2009-11-01

    In this work, the mathematical optimization of a continuous flash fermentation process for the production of biobutanol was studied. The process consists of three interconnected units, as follows: fermentor, cell-retention system (tangential microfiltration), and vacuum flash vessel (responsible for the continuous recovery of butanol from the broth). The objective of the optimization was to maximize butanol productivity for a desired substrate conversion. Two strategies were compared for the optimization of the process. In one of them, the process was represented by a deterministic model with kinetic parameters determined experimentally and, in the other, by a statistical model obtained using the factorial design technique combined with simulation. For both strategies, the problem was written as a nonlinear programming problem and was solved with the sequential quadratic programming technique. The results showed that despite the very similar solutions obtained with both strategies, the problems found with the strategy using the deterministic model, such as lack of convergence and high computational time, make the use of the optimization strategy with the statistical model, which showed to be robust and fast, more suitable for the flash fermentation process, being recommended for real-time applications coupling optimization and control.

  5. Protective role of female gender in programmed accelerated renal aging in the rat.

    Science.gov (United States)

    Pijacka, Wioletta; Clifford, Bethan; Tilburgs, Chantal; Joles, Jaap A; Langley-Evans, Simon; McMullen, Sarah

    2015-04-01

    The aging kidney exhibits a progressive decline in glomerular filtration rate, accompanied by inflammatory and oxidative damage. We hypothesized that accelerated, age-related progression of renal injury is ovarian hormones-dependant. To address this we used an established model of developmentally programmed accelerated renal aging in the rat, superimposed by ovariectomy to assess interactions between ovarian hormones and the aging process. Under our experimental conditions, we found that kidney function worsens with age, that is GFR reduces over 18 month analyzed time-course and this was worsened by fetal exposure to maternal low-protein diet and absence of estrogen. Reduction in GFR was followed by increases in albuminuria, proteinuria, inflammatory markers, and tissue carbonyls, all suggesting inflammatory response and oxidative stress. This was associated with changes in AGTR2 expression which was greater at 18 months of age compared to earlier time points, but in MLP offspring only. Our studies show an influence of ovarian hormones on programmed accelerated renal aging and the AGTR2 across the lifespan. The main findings are that ovariectomy is a risk factor for increased aging-related renal injury and that this and oxidative damage might be related to changes in AGTR2 expression. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  6. Can Accelerators Accelerate Learning?

    International Nuclear Information System (INIS)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-01-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ)[1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  7. Can Accelerators Accelerate Learning?

    Science.gov (United States)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-03-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ) [1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  8. High Gradient Accelerator Research

    International Nuclear Information System (INIS)

    Temkin, Richard

    2016-01-01

    The goal of the MIT program of research on high gradient acceleration is the development of advanced acceleration concepts that lead to a practical and affordable next generation linear collider at the TeV energy level. Other applications, which are more near-term, include accelerators for materials processing; medicine; defense; mining; security; and inspection. The specific goals of the MIT program are: • Pioneering theoretical research on advanced structures for high gradient acceleration, including photonic structures and metamaterial structures; evaluation of the wakefields in these advanced structures • Experimental research to demonstrate the properties of advanced structures both in low-power microwave cold test and high-power, high-gradient test at megawatt power levels • Experimental research on microwave breakdown at high gradient including studies of breakdown phenomena induced by RF electric fields and RF magnetic fields; development of new diagnostics of the breakdown process • Theoretical research on the physics and engineering features of RF vacuum breakdown • Maintaining and improving the Haimson / MIT 17 GHz accelerator, the highest frequency operational accelerator in the world, a unique facility for accelerator research • Providing the Haimson / MIT 17 GHz accelerator facility as a facility for outside users • Active participation in the US DOE program of High Gradient Collaboration, including joint work with SLAC and with Los Alamos National Laboratory; participation of MIT students in research at the national laboratories • Training the next generation of Ph. D. students in the field of accelerator physics.

  9. Breast Conserving Treatment for Breast Cancer: Dosimetric Comparison of Sequential versus Simultaneous Integrated Photon Boost

    Directory of Open Access Journals (Sweden)

    Hilde Van Parijs

    2014-01-01

    Full Text Available Background. Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast. Methods. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed. Results. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P = 0.0001. There was less dose spilling to the ipsilateral breast outside the PTVboost (P = 0.04. The dose to the organs at risk (OAR was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient. Conclusions. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine.

  10. a method of gravity and seismic sequential inversion and its GPU implementation

    Science.gov (United States)

    Liu, G.; Meng, X.

    2011-12-01

    In this abstract, we introduce a gravity and seismic sequential inversion method to invert for density and velocity together. For the gravity inversion, we use an iterative method based on correlation imaging algorithm; for the seismic inversion, we use the full waveform inversion. The link between the density and velocity is an empirical formula called Gardner equation, for large volumes of data, we use the GPU to accelerate the computation. For the gravity inversion method , we introduce a method based on correlation imaging algorithm,it is also a interative method, first we calculate the correlation imaging of the observed gravity anomaly, it is some value between -1 and +1, then we multiply this value with a little density ,this value become the initial density model. We get a forward reuslt with this initial model and also calculate the correaltion imaging of the misfit of observed data and the forward data, also multiply the correaltion imaging result a little density and add it to the initial model, then do the same procedure above , at last ,we can get a inversion density model. For the seismic inveron method ,we use a mothod base on the linearity of acoustic wave equation written in the frequency domain,with a intial velociy model, we can get a good velocity result. In the sequential inversion of gravity and seismic , we need a link formula to convert between density and velocity ,in our method , we use the Gardner equation. Driven by the insatiable market demand for real time, high-definition 3D images, the programmable NVIDIA Graphic Processing Unit (GPU) as co-processor of CPU has been developed for high performance computing. Compute Unified Device Architecture (CUDA) is a parallel programming model and software environment provided by NVIDIA designed to overcome the challenge of using traditional general purpose GPU while maintaining a low learn curve for programmers familiar with standard programming languages such as C. In our inversion processing

  11. The CEBAF accelerator and its physics program

    International Nuclear Information System (INIS)

    Cardman, L.S.

    1993-01-01

    The continuous electron beam accelerator facility (CEBAF) consists of a pair of 400 MeV superconducting linacs together with a 5-pass recirculation system and beam switchyard that will permit it to provide three, simultaneous 4 GeV, cw electron beams with a total current of up to 200 μA. The conventional construction for the accelerator and the three experimental end stations is essentially complete. The first linac has been installed in the accelerator tunnel and beam has been accelerated through it; all tests to date have met or exceeded the design specifications. The major components of the experimental equipment for the end stations are under construction. Operation of CEBAF for nuclear physics is scheduled to begin in mid-1994. The facility will support a broad range of nuclear physics research, including topics such as how quarks and gluons are held together in protons and neutrons, the origins of the nuclear force, modifications of nucleons in the nuclear medium, and nuclear structure when nucleons are very close together. The status of the accelerator and its experimental equipment will be presented together with a sampling of experiments planned for the early phases of operation

  12. Establishment of an Advanced Accelerator Applications University Participation Program at the University of Nevada, Las Vegas

    International Nuclear Information System (INIS)

    Hechanova, A.E.; Cerefice, G.S.

    2002-01-01

    The University of Nevada, Las Vegas (UNLV) established an Advanced Accelerator Applications (AAA) University Participation Program in March 2001 to develop a world-class research program for accelerator-driven transmutation technology while building core competencies and facilities to promote the University's strategic growth goals. The goal of this program is to involve UNLV students in research on the cutting edge of science and engineering as an integrated part of the national program to develop this emerging technology. This program augments UNLV's research capabilities and infrastructure, while establishing national and international research collaborations with national laboratories, industrial partners, and other universities, increasing the UNL V research community's presence in the global scientific community. The UNL V Program is closely integrated into the national project led by Los Alamos and Argonne National Laboratories. The primary mechanism to insure this degree of integration is the teaming of national laboratory scientists with UNL V faculty and students on student research proposals. The Program was implemented under an aggressive schedule with faculty response that surpassed expectations. A total of 12 multi-tasked projects that involve 21 graduate students and 13 faculty members began under first year funding. Other major accomplishments include establishment of an administrative structure implementing all the components of the Program and establishment of a communications network between national laboratory project leaders and UNL V faculty. (authors)

  13. Accomplishments of the heavy electron particle accelerator program

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, D. [Fermilab; Stratakis, D. [Fermilab; Palmer, M. [Brookhaven; Delahaye, J-P [SLAC; Summers, D. [Mississippi U.; Ryne, R. [LBNL, Berkeley; Cummings, M. A. [MUONS Inc.

    2016-10-18

    The Muon Accelerator Program (MAP) has completed a four-year study on the feasibility of muon colliders and on using stored muon beams for neutrinos. That study was broadly successful in its goals, establishing the feasibility of heavy lepton colliders (HLCs) from the 125 GeV Higgs Factory to more than 10 TeV, as well as exploring using a μ storage ring (MSR) for neutrinos, and establishing that MSRs could provide factory-level intensities of νe ($\\bar{ve}$) and $\\bar{vμ}$ (νμ) beams. The key components of the collider and neutrino factory systems were identified. Feasible designs and detailed simulations of all of these components have been obtained, including some initial hardware component tests, setting the stage for future implementation where resources are available and the precise physics goals become apparent.

  14. Accelerator technology in tokamaks

    International Nuclear Information System (INIS)

    Kustom, R.L.

    1977-01-01

    This article presents the similarities in the technology required for high energy accelerators and tokamak fusion devices. The tokamak devices and R and D programs described in the text represent only a fraction of the total fusion program. The technological barriers to producing successful, economical tokamak fusion power plants are as many as the plasma physics problems to be overcome. With the present emphasis on energy problems in this country and elsewhere, it is very likely that fusion technology related R and D programs will vigorously continue; and since high energy accelerator technology has so much in common with fusion technology, more scientists from the accelerator community are likely to be attracted to fusion problems

  15. Accelerator Technology Division progress report, FY 1992

    Energy Technology Data Exchange (ETDEWEB)

    Schriber, S.O.; Hardekopf, R.A.; Heighway, E.A.

    1993-07-01

    This report briefly discusses the following topics: The Ground Test Accelerator Program; Defense Free-Electron Lasers; AXY Programs; A Next Generation High-Power Neutron-Scattering Facility; JAERI OMEGA Project and Intense Neutron Sources for Materials Testing; Advanced Free-Electron Laser Initiative; Superconducting Supercollider; The High-Power Microwave (HPM) Program; Neutral Particle Beam (NPB) Power Systems Highlights; Industrial Partnering; Accelerator Physics and Special Projects; Magnetic Optics and Beam Diagnostics; Accelerator Design and Engineering; Radio-Frequency Technology; Accelerator Theory and Free-Electron Laser Technology; Accelerator Controls and Automation; Very High-Power Microwave Sources and Effects; and GTA Installation, Commissioning, and Operations.

  16. Accelerator Technology Division progress report, FY 1992

    International Nuclear Information System (INIS)

    Schriber, S.O.; Hardekopf, R.A.; Heighway, E.A.

    1993-07-01

    This report briefly discusses the following topics: The Ground Test Accelerator Program; Defense Free-Electron Lasers; AXY Programs; A Next Generation High-Power Neutron-Scattering Facility; JAERI OMEGA Project and Intense Neutron Sources for Materials Testing; Advanced Free-Electron Laser Initiative; Superconducting Supercollider; The High-Power Microwave (HPM) Program; Neutral Particle Beam (NPB) Power Systems Highlights; Industrial Partnering; Accelerator Physics and Special Projects; Magnetic Optics and Beam Diagnostics; Accelerator Design and Engineering; Radio-Frequency Technology; Accelerator Theory and Free-Electron Laser Technology; Accelerator Controls and Automation; Very High-Power Microwave Sources and Effects; and GTA Installation, Commissioning, and Operations

  17. Dynamic EBF1 occupancy directs sequential epigenetic and transcriptional events in B-cell programming.

    Science.gov (United States)

    Li, Rui; Cauchy, Pierre; Ramamoorthy, Senthilkumar; Boller, Sören; Chavez, Lukas; Grosschedl, Rudolf

    2018-01-15

    B-cell fate determination requires the action of transcription factors that operate in a regulatory network to activate B-lineage genes and repress lineage-inappropriate genes. However, the dynamics and hierarchy of events in B-cell programming remain obscure. To uncouple the dynamics of transcription factor expression from functional consequences, we generated induction systems in developmentally arrested Ebf1 -/- pre-pro-B cells to allow precise experimental control of EBF1 expression in the genomic context of progenitor cells. Consistent with the described role of EBF1 as a pioneer transcription factor, we show in a time-resolved analysis that EBF1 occupancy coincides with EBF1 expression and precedes the formation of chromatin accessibility. We observed dynamic patterns of EBF1 target gene expression and sequential up-regulation of transcription factors that expand the regulatory network at the pro-B-cell stage. A continuous EBF1 function was found to be required for Cd79a promoter activity and for the maintenance of an accessible chromatin domain that is permissive for binding of other transcription factors. Notably, transient EBF1 occupancy was detected at lineage-inappropriate genes prior to their silencing in pro-B cells. Thus, persistent and transient functions of EBF1 allow for an ordered sequence of epigenetic and transcriptional events in B-cell programming. © 2018 Li et al.; Published by Cold Spring Harbor Laboratory Press.

  18. Self-perception of readiness for clinical practice: A survey of accelerated Masters program graduate registered nurses.

    Science.gov (United States)

    Cantlay, Andrew; Salamanca, Jennifer; Golaw, Cherie; Wolf, Daniel; Maas, Carly; Nicholson, Patricia

    2017-05-01

    Accelerated nursing programs are gaining momentum as a means of career transition into the nursing profession for mature age learners in an attempt to meet future healthcare workforce demands in Australia. With a gap in the literature on readiness for practice of graduates from accelerated nursing programs at the Masters level the purpose of this study was to evaluate the effectiveness of the program based on graduates' preparedness for practice and graduate outcomes. Using a descriptive, exploratory design an online survey was used to explore the perception of graduate nurses' readiness for clinical practice. Forty-nine graduates from a nursing Masters program at an Australian university completed the survey defining readiness for practice as knowledge of self-limitations and seeking help, autonomy in basic clinical procedures, exhibiting confidence, possessing theoretical knowledge and practicing safe care. Graduates perceived themselves as adequately prepared to work as a beginner practitioner with their perception of readiness for clinical practice largely positive. The majority of participants agreed that the program had prepared them for work as a beginner practitioner with respondents stating that they felt adequately prepared in most areas relating to clinical practice. This would suggest that educational preparation was adequate and effective in achieving program objectives. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. OpenMP for Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, J C; Stotzer, E J; Hart, A; de Supinski, B R

    2011-03-15

    OpenMP [13] is the dominant programming model for shared-memory parallelism in C, C++ and Fortran due to its easy-to-use directive-based style, portability and broad support by compiler vendors. Similar characteristics are needed for a programming model for devices such as GPUs and DSPs that are gaining popularity to accelerate compute-intensive application regions. This paper presents extensions to OpenMP that provide that programming model. Our results demonstrate that a high-level programming model can provide accelerated performance comparable to hand-coded implementations in CUDA.

  20. Design of incentive programs for accelerating penetration of energy-efficient appliances

    International Nuclear Information System (INIS)

    Rue du Can de la, Stephane; Leventis, Greg; Phadke, Amol; Gopal, Anand

    2014-01-01

    Incentives are policy tools that sway purchase, retail stocking, and production decisions toward energy-efficient products. Incentives complement mandatory standards and labeling policies by accelerating market penetration of products that are more energy efficient than required by existing standards and by preparing the market for more stringent future mandatory requirements. Incentives can be directed at different points in the appliance's supply chain; one point may be more effective than another depending on the technology's maturity and market penetration. This paper seeks to inform future policy and program design by categorizing the main elements of incentive programs from around the world. We identify advantages and disadvantages of program designs through a qualitative overview of incentive programs worldwide. We find that financial incentive programs have greater impact when they target highly efficient technologies with a small market share, and that program designs depend on the market barriers addressed, the target equipment, and the local market context. No program design is inherently superior to another. The key to successful program design and implementation is a thorough understanding of the market and identification of the most important local obstacles to the penetration of energy-efficient technologies. - Highlights: • We researched incentive programs design and implementation worldwide. • This paper seeks to inform future policy and program design. • We identify design and identify advantages and disadvantages. • We find that incentive programs have greater impact when they target highly efficient products. • Program designs depend on the market barriers addressed and the local market context

  1. Accelerator development

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Because the use of accelerated heavy ions would provide many opportunities for new and important studies in nuclear physics and nuclear chemistry, as well as other disciplines, both the Chemistry and Physics Divisions are supporting the development of a heavy-ion accelerator. The design of greatest current interest includes a tandem accelerator with a terminal voltage of approximately 25 MV injecting into a linear accelerator with rf superconducting resonators. This combined accelerator facility would be capable of accelerating ions of masses ranging over the entire periodic table to an energy corresponding to approximately 10 MeV/nucleon. This approach, as compared to other concepts, has the advantages of lower construction costs, lower operating power, 100 percent duty factor, and high beam quality (good energy resolution, good timing resolution, small beam size, and small beam divergence). The included sections describe the concept of the proposed heavy-ion accelerator, and the development program aiming at: (1) investigation of the individual questions concerning the superconducting accelerating resonators; (2) construction and testing of prototype accelerator systems; and (3) search for economical solutions to engineering problems. (U.S.)

  2. Sequential Online Wellness Programming Is an Effective Strategy to Promote Behavior Change

    Science.gov (United States)

    MacNab, Lindsay R.; Francis, Sarah L.

    2015-01-01

    The growing number of United States youth and adults categorized as overweight or obese illustrates a need for research-based family wellness interventions. Sequential, online, Extension-delivered family wellness interventions offer a time- and cost-effective approach for both participants and Extension educators. The 6-week, online Healthy…

  3. Accelerator technology program. Progress report, January-June 1981

    International Nuclear Information System (INIS)

    Knapp, E.A.; Jameson, R.A.

    1982-05-01

    This report covers the activities of Los Alamos National Laboratory's Accelerator Technology Division during the first 6 months of calendar 1981. We discuss the Division's major projects, which reflect a variety of applications and sponsors. The varied technologies concerned with the Proton Storage ring are concerned with the Proton Storage Ring are continuing and are discussed in detail. For the racetrack microtron (RTM) project, the major effort has been the design and construction of the demonstration RTM. Our development of the radio-frequency quadrupole (RFQ) linear accelerator continues to stimulate interest for many possible applications. Frequent contacts from other laboratories have revealed a wide acceptance of the RFQ principle in solving low-velocity acceleration problems. In recent work on heavy ion fusion we have developed ideas for funneling beams from RFQ linacs; the funneling process is explained. To test as many aspects as possible of a fully integrated low-energy portion of a Pion generator for Medical Irradiation (PIGMI) Accelerator, a prototype accelerator was designed to take advantage of several pieces of existing accelerator hardware. The important principles to be tested in this prototype accelerator are detailed. Our prototype gyrocon has been extensively tested and modified; we discuss results from our investigations. Our work with the Fusion Materials Irradiation Test Facility is reviewed in this report

  4. Topology optimization of induction heating model using sequential linear programming based on move limit with adaptive relaxation

    Science.gov (United States)

    Masuda, Hiroshi; Kanda, Yutaro; Okamoto, Yoshifumi; Hirono, Kazuki; Hoshino, Reona; Wakao, Shinji; Tsuburaya, Tomonori

    2017-12-01

    It is very important to design electrical machineries with high efficiency from the point of view of saving energy. Therefore, topology optimization (TO) is occasionally used as a design method for improving the performance of electrical machinery under the reasonable constraints. Because TO can achieve a design with much higher degree of freedom in terms of structure, there is a possibility for deriving the novel structure which would be quite different from the conventional structure. In this paper, topology optimization using sequential linear programming using move limit based on adaptive relaxation is applied to two models. The magnetic shielding, in which there are many local minima, is firstly employed as firstly benchmarking for the performance evaluation among several mathematical programming methods. Secondly, induction heating model is defined in 2-D axisymmetric field. In this model, the magnetic energy stored in the magnetic body is maximized under the constraint on the volume of magnetic body. Furthermore, the influence of the location of the design domain on the solutions is investigated.

  5. Modelling sequentially scored item responses

    NARCIS (Netherlands)

    Akkermans, W.

    2000-01-01

    The sequential model can be used to describe the variable resulting from a sequential scoring process. In this paper two more item response models are investigated with respect to their suitability for sequential scoring: the partial credit model and the graded response model. The investigation is

  6. Adult student satisfaction in an accelerated RN-to-BSN program: a follow-up study.

    Science.gov (United States)

    Boylston, Mary T; Jackson, Christina

    2008-01-01

    This mixed-method study revealed accelerated RN-to-BSN (bachelor of science in nursing) students' levels of satisfaction with a wide range of college services in a small university. Building on seminal research on the topic [Boylston, M. T., Peters, M. A., & Lacey, M. (2004). Adult student satisfaction in traditional and accelerated RN-to-BSN programs. Journal of Professional Nursing, 20, 23-32.], the Noel-Levitz Adult Student Priorities Survey (ASPS) and qualitative interview data revealed primary factors involved in nontraditional (adult) accelerated RN-to-BSN student satisfaction. The ASPS assesses both satisfaction with and importance of the following factors: academic advising effectiveness, academic services, admissions and financial aid effectiveness, campus climate, instructional effectiveness, registration effectiveness, safety and security, and service excellence. Of these factors, participants considered instructional effectiveness and academic advising effectiveness as most important and concomitantly gave high satisfaction ratings to each. In contrast, convenience of the bookstore, counseling services, vending machines, and computer laboratories were given low importance ratings. The participants cited convenience as a strong marketing factor. Loss of financial aid or family crisis was given as a reason for withdrawal and, for most students, would be the only reason for not completing the BSN program. Outcomes of this investigation may guide faculty, staff, and administrators in proactively creating an educational environment in which a nontraditional student can succeed.

  7. Development of an Efficient GPU-Accelerated Model for Fully Nonlinear Water Waves

    DEFF Research Database (Denmark)

    of an optimized sequential single-CPU algorithm based on a flexible-order Finite Difference Method. High performance is pursued by utilizing many-core processing in the model focusing on GPUs for acceleration of code execution. This involves combining analytical methods with an algorithm redesign of the current...

  8. Polarized proton acceleration program at the AGS

    International Nuclear Information System (INIS)

    Lee, Y.Y.

    1981-01-01

    The unexpected importance of high energy spin effects and the success of the ZGS in correcting many intrinsic and imperfection depolarizing resonances led us to attempt to accelerate polarized protons in the AGS. A multi-university/laboratory collaborative effort involving Argonne, Brookhaven, Michigan, Rice and Yale is underway to improve and modify to accelerate polarized protons. From the experience at the ZGS and careful studies made us confident of the feasibility of achieving a polarization of over 60 percent up to 26 GeV/c with an intensity of 10 11 approx. 10 12 per pulse. The first polarized proton acceleration at the AGS is expected in 1983

  9. On-Chip Laser-Power Delivery System for Dielectric Laser Accelerators

    Science.gov (United States)

    Hughes, Tyler W.; Tan, Si; Zhao, Zhexin; Sapra, Neil V.; Leedle, Kenneth J.; Deng, Huiyang; Miao, Yu; Black, Dylan S.; Solgaard, Olav; Harris, James S.; Vuckovic, Jelena; Byer, Robert L.; Fan, Shanhui; England, R. Joel; Lee, Yun Jo; Qi, Minghao

    2018-05-01

    We propose an on-chip optical-power delivery system for dielectric laser accelerators based on a fractal "tree-network" dielectric waveguide geometry. This system replaces experimentally demanding free-space manipulations of the driving laser beam with chip-integrated techniques based on precise nanofabrication, enabling access to orders-of-magnitude increases in the interaction length and total energy gain for these miniature accelerators. Based on computational modeling, in the relativistic regime, our laser delivery system is estimated to provide 21 keV of energy gain over an acceleration length of 192 μ m with a single laser input, corresponding to a 108-MV/m acceleration gradient. The system may achieve 1 MeV of energy gain over a distance of less than 1 cm by sequentially illuminating 49 identical structures. These findings are verified by detailed numerical simulation and modeling of the subcomponents, and we provide a discussion of the main constraints, challenges, and relevant parameters with regard to on-chip laser coupling for dielectric laser accelerators.

  10. Beam trajectory simulation program at the National Institute of Nuclear Research Tandem Accelerator facility

    International Nuclear Information System (INIS)

    Murillo C, G.

    1996-01-01

    The main object of this thesis is to show in a clear and simple way to the people in general, the function of the Tandem Accelerator located on site the ININ facilities. For this presentation, a computer program was developed. The software written in C language in a structural form, simulates the ion production and its trajectory in a schematic and in an easy way to comprehend. According to the goals of this work, the simulation also shows details of some of the machine components like the source, the accelerator cavity, ,and the bombarding chamber. Electric and magnetic fields calculations are included for the 90 degrees bending magnet and quadrupoles. (Author)

  11. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.

    2014-12-15

    This paper considers multi-agent sequential hypothesis testing and presents a framework for strategic learning in sequential games with explicit consideration of both temporal and spatial coordination. The associated Bayes risk functions explicitly incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well-defined value functions with respect to (a) the belief states for the case of conditional independent private noisy measurements that are also assumed to be independent identically distributed over time, and (b) the information states for the case of correlated private noisy measurements. A sequential investment game of strategic coordination and delay is also discussed as an application of the proposed strategic learning rules.

  12. Experiences and emotions of faculty teaching in accelerated second baccalaureate degree nursing programs.

    Science.gov (United States)

    Brandt, Cheryl L; Boellaard, Melissa R; Zorn, Cecelia R

    2013-07-01

    The number of accelerated second baccalaureate degree nursing (ASBSN) programs has mushroomed over recent decades, with more than 225 currently in existence. Scholars have described students and programs, but research examining the faculty experience is limited. The purpose of this study was to describe the experiences and emotions of faculty teaching students in ASBSN programs. Using a descriptive qualitative survey design, faculty (N = 138) from 25 randomly selected programs in 11 midwestern states were surveyed using an instrument developed for this study and distributed online. Ten themes emerged, including (a) Engaging With Motivated, Mature, and Diverse Students, (b) Students Choosing Nursing for the "Wrong Reasons," (c) Too Much Work, Too Little Time for Students and Faculty, (d) Amazement, (e) Pride, and (f) Frustration. These findings will help novice and seasoned ASBSN faculty interpret their experiences, strengthen precepting and mentoring activities, and support administrators in determining staffing plans and designing ASBSN programs. Copyright 2013, SLACK Incorporated.

  13. Final Report to the Department of Energy on the 1994 International Accelerator School: Frontiers of Accelerator Technology

    International Nuclear Information System (INIS)

    Harris, F.A.

    1998-01-01

    The international accelerator school on Frontiers of Accelerator Technology was organized jointly by the US Particle Accelerator School (Dr. Mel Month and Ms. Marilyn Paul), the CERN Accelerator School, and the KEK Accelerator School, and was hosted by the University of Hawaii. The course was held on Maui, Hawaii, November 3-9, 1994 and was made possible in part by a grant from the Department of Energy under award number DE-FG03-94ER40875, AMDT M006. The 1994 program was preceded by similar joint efforts held at Santa Margherita di Pula, Sardinia in February 1985, South Padre Island, Texas in October 1986, Anacapri, Italy in October 1988, Hilton Head Island, South Carolina in October 1990, and Benalmedena, Spain in October/November 1992. The most recent program was held in Montreux, Switzerland in May 1998. The purpose of the program is to disseminate knowledge on the latest ideas and developments in the technology of particle accelerators by bringing together known world experts and younger scientists in the field. It is intended for individuals with professional interest in accelerator physics and technology, for graduate students, for post-docs, for those interested in accelerator based sciences, and for scientific and engineering staff at industrial firms, especially those companies specializing in accelerator components

  14. Sequential charged particle reaction

    International Nuclear Information System (INIS)

    Hori, Jun-ichi; Ochiai, Kentaro; Sato, Satoshi; Yamauchi, Michinori; Nishitani, Takeo

    2004-01-01

    The effective cross sections for producing the sequential reaction products in F82H, pure vanadium and LiF with respect to the 14.9-MeV neutron were obtained and compared with the estimation ones. Since the sequential reactions depend on the secondary charged particles behavior, the effective cross sections are corresponding to the target nuclei and the material composition. The effective cross sections were also estimated by using the EAF-libraries and compared with the experimental ones. There were large discrepancies between estimated and experimental values. Additionally, we showed the contribution of the sequential reaction on the induced activity and dose rate in the boundary region with water. From the present study, it has been clarified that the sequential reactions are of great importance to evaluate the dose rates around the surface of cooling pipe and the activated corrosion products. (author)

  15. The Accelerator Markup Language and the Universal Accelerator Parser

    International Nuclear Information System (INIS)

    Sagan, D.; Forster, M.; Cornell U., LNS; Bates, D.A.; LBL, Berkeley; Wolski, A.; Liverpool U.; Cockcroft Inst. Accel. Sci. Tech.; Schmidt, F.; CERN; Walker, N.J.; DESY; Larrieu, T.; Roblin, Y.; Jefferson Lab; Pelaia, T.; Oak Ridge; Tenenbaum, P.; Woodley, M.; SLAC; Reiche, S.; UCLA

    2006-01-01

    A major obstacle to collaboration on accelerator projects has been the sharing of lattice description files between modeling codes. To address this problem, a lattice description format called Accelerator Markup Language (AML) has been created. AML is based upon the standard eXtensible Markup Language (XML) format; this provides the flexibility for AML to be easily extended to satisfy changing requirements. In conjunction with AML, a software library, called the Universal Accelerator Parser (UAP), is being developed to speed the integration of AML into any program. The UAP is structured to make it relatively straightforward (by giving appropriate specifications) to read and write lattice files in any format. This will allow programs that use the UAP code to read a variety of different file formats. Additionally, this will greatly simplify conversion of files from one format to another. Currently, besides AML, the UAP supports the MAD lattice format

  16. Bidding in sequential electricity markets: The Nordic case

    DEFF Research Database (Denmark)

    Boomsma, Trine Krogh; Juul, Nina; Fleten, Stein-Erik

    2014-01-01

    problem as a multi-stage stochastic program. We investigate whether higher risk exposure can explain the hesitation, often observed in practice, to bid into the balancing market, even in cases of higher expected price levels. Furthermore, we quantify the gain from coordinated bidding, and by deriving......For electricity market participants trading in sequential markets with differences in price levels and risk exposure, coordinated bidding is highly relevant. We consider a Nordic power producer who engages in the day-ahead spot market and the near real-time balancing market. In both markets......, clearing prices and dispatched volumes are unknown at the time of bidding. However, in the balancing market, the agent faces an additional risk of not being dispatched. Taking into account the sequential clearing of these markets and the gradual realization of market prices, we formulate the bidding...

  17. Community petascale project for accelerator science and simulation: Advancing computational science for future accelerators and accelerator technologies

    International Nuclear Information System (INIS)

    Spentzouris, P.; Cary, J.; McInnes, L.C.; Mori, W.; Ng, C.; Ng, E.; Ryne, R.

    2008-01-01

    The design and performance optimization of particle accelerators are essential for the success of the DOE scientific program in the next decade. Particle accelerators are very complex systems whose accurate description involves a large number of degrees of freedom and requires the inclusion of many physics processes. Building on the success of the SciDAC-1 Accelerator Science and Technology project, the SciDAC-2 Community Petascale Project for Accelerator Science and Simulation (ComPASS) is developing a comprehensive set of interoperable components for beam dynamics, electromagnetics, electron cooling, and laser/plasma acceleration modelling. ComPASS is providing accelerator scientists the tools required to enable the necessary accelerator simulation paradigm shift from high-fidelity single physics process modeling (covered under SciDAC1) to high-fidelity multiphysics modeling. Our computational frameworks have been used to model the behavior of a large number of accelerators and accelerator R and D experiments, assisting both their design and performance optimization. As parallel computational applications, the ComPASS codes have been shown to make effective use of thousands of processors.

  18. Impetus and Creation of an Accelerated Second-Degree Baccalaureate Nursing Program Readmission Policy

    Directory of Open Access Journals (Sweden)

    Joanne Schwartz PhD, PMHNP-BC, CNE

    2017-04-01

    Full Text Available An accelerated second-degree baccalaureate nursing (ASDBN is an academic plan of study typically 12 to 24 months in duration. ASDBN students make many changes when entering this type of program. Some of the major changes ASDBN students make when entering an ASDBN program include leaving jobs, incurring debt, draining financial resources, forgoing time with children, spouses, and significant others, and, in some cases, relocating far from family and support systems. Because of the nature and scope of the many sacrifices ASDBN students typically make, academic program dismissal is particularly traumatic and devastating. It is not uncommon for an ASDBN student to seek program readmission when they are dismissed for academic reasons. Many academically dismissed ASDBN students seek program readmission. Administrators face a challenging decision in program readmission requests. The key issue with program readmission of ASDBN students is having a rigorous and comprehensive policy to determine which ASDBN students should be readmitted. This article examines one large, private, urban university’s ASDBN program’s readmission policy design and how the policy is applied to manage and determine ASDBN program readmission requests.

  19. Eyewitness confidence in simultaneous and sequential lineups: a criterion shift account for sequential mistaken identification overconfidence.

    Science.gov (United States)

    Dobolyi, David G; Dodson, Chad S

    2013-12-01

    Confidence judgments for eyewitness identifications play an integral role in determining guilt during legal proceedings. Past research has shown that confidence in positive identifications is strongly associated with accuracy. Using a standard lineup recognition paradigm, we investigated accuracy using signal detection and ROC analyses, along with the tendency to choose a face with both simultaneous and sequential lineups. We replicated past findings of reduced rates of choosing with sequential as compared to simultaneous lineups, but notably found an accuracy advantage in favor of simultaneous lineups. Moreover, our analysis of the confidence-accuracy relationship revealed two key findings. First, we observed a sequential mistaken identification overconfidence effect: despite an overall reduction in false alarms, confidence for false alarms that did occur was higher with sequential lineups than with simultaneous lineups, with no differences in confidence for correct identifications. This sequential mistaken identification overconfidence effect is an expected byproduct of the use of a more conservative identification criterion with sequential than with simultaneous lineups. Second, we found a steady drop in confidence for mistaken identifications (i.e., foil identifications and false alarms) from the first to the last face in sequential lineups, whereas confidence in and accuracy of correct identifications remained relatively stable. Overall, we observed that sequential lineups are both less accurate and produce higher confidence false identifications than do simultaneous lineups. Given the increasing prominence of sequential lineups in our legal system, our data argue for increased scrutiny and possibly a wholesale reevaluation of this lineup format. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  20. An accelerated stress testing program for determining the reliability sensitivity of silicon solar cells to encapsulation and metallization systems

    Science.gov (United States)

    Lathrop, J. W.; Davis, C. W.; Royal, E.

    1982-01-01

    The use of accelerated testing methods in a program to determine the reliability attributes of terrestrial silicon solar cells is discussed. Different failure modes are to be expected when cells with and without encapsulation are subjected to accelerated testing and separate test schedules for each are described. Unencapsulated test cells having slight variations in metallization are used to illustrate how accelerated testing can highlight different diffusion related failure mechanisms. The usefulness of accelerated testing when applied to encapsulated cells is illustrated by results showing that moisture related degradation may be many times worse with some forms of encapsulation than with no encapsulation at all.

  1. Sequential Optimization of Paths in Directed Graphs Relative to Different Cost Functions

    KAUST Repository

    Abubeker, Jewahir Ali; Chikalov, Igor; Hussain, Shahid; Moshkov, Mikhail

    2011-01-01

    This paper is devoted to the consideration of an algorithm for sequential optimization of paths in directed graphs relative to di_erent cost functions. The considered algorithm is based on an extension of dynamic programming which allows

  2. Proposal for an Accelerator R&D User Facility at Fermilab's Advanced Superconducting Test Accelerator (ASTA)

    Energy Technology Data Exchange (ETDEWEB)

    Church, M. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Edwards, H. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Harms, E. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Henderson, S. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Holmes, S. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Lumpkin, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Kephart, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Levedev, V. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Leibfritz, J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Nagaitsev, S. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Piot, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Northern Illinois Univ., DeKalb, IL (United States); Prokop, C. [Northern Illinois Univ., DeKalb, IL (United States); Shiltsev, V. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Sun, Y. E. [Argonne National Lab. (ANL), Argonne, IL (United States); Valishev, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2013-10-01

    Fermilab is the nation’s particle physics laboratory, supported by the DOE Office of High Energy Physics (OHEP). Fermilab is a world leader in accelerators, with a demonstrated track-record— spanning four decades—of excellence in accelerator science and technology. We describe the significant opportunity to complete, in a highly leveraged manner, a unique accelerator research facility that supports the broad strategic goals in accelerator science and technology within the OHEP. While the US accelerator-based HEP program is oriented toward the Intensity Frontier, which requires modern superconducting linear accelerators and advanced highintensity storage rings, there are no accelerator test facilities that support the accelerator science of the Intensity Frontier. Further, nearly all proposed future accelerators for Discovery Science will rely on superconducting radiofrequency (SRF) acceleration, yet there are no dedicated test facilities to study SRF capabilities for beam acceleration and manipulation in prototypic conditions. Finally, there are a wide range of experiments and research programs beyond particle physics that require the unique beam parameters that will only be available at Fermilab’s Advanced Superconducting Test Accelerator (ASTA). To address these needs we submit this proposal for an Accelerator R&D User Facility at ASTA. The ASTA program is based on the capability provided by an SRF linac (which provides electron beams from 50 MeV to nearly 1 GeV) and a small storage ring (with the ability to store either electrons or protons) to enable a broad range of beam-based experiments to study fundamental limitations to beam intensity and to develop transformative approaches to particle-beam generation, acceleration and manipulation which cannot be done elsewhere. It will also establish a unique resource for R&D towards Energy Frontier facilities and a test-bed for SRF accelerators and high brightness beam applications in support of the OHEP

  3. Laser power sources and laser technology for accelerators

    International Nuclear Information System (INIS)

    Lowenthal, D.

    1986-01-01

    The requirements on laser power sources for advanced accelerator concepts are formidable. These requirements are driven by the need to deliver 5 TeV particles at luminosities of 10/sup 33/ - 10/sup 34/ cm/sup -2/ sec/sup -1/. Given that optical power can be transferred efficiently to the particles these accelerator parameters translate into single pulse laser output energies of several kilojoules and rep rates of 1-10 kHz. The average laser output power is then 10-20 MW. Larger average powers will be needed if efficient transfer proves not to be possible. A laser plant of this magnitude underscores the importance of high wall plug efficiency and reasonable cost in $/Watt. The interface between the laser output pulse format and the accelerator structure is another area that drives the laser requirements. Laser accelerators break up into two general architectures depending on the strength of the laser coupling. For strong coupling mechanisms, the architecture requires many ''small'' lasers powering the accelerator in a staged arrangement. For the weak coupling mechanisms, the architecture must feature a single large laser system whose power must be transported along the entire accelerator length. Both of these arrangements have demanding optical constraints in terms of phase matching sequential stages, beam combining arrays of laser outputs and optimizing coupling of laser power in a single accelerating stage

  4. Accelerator breeder concept

    International Nuclear Information System (INIS)

    Bartholomew, G.A.; Fraser, J.S.; Garvey, P.M.

    1978-10-01

    The principal components and functions of an accelerator breeder are described. The role of the accelerator breeder as a possible long-term fissile production support facility for CANDU (Canada Deuterium Uranium) thorium advanced fuel cycles and the Canadian research and development program leading to such a facility are outlined. (author)

  5. Accelerator microanalysis

    International Nuclear Information System (INIS)

    Tuniz, C.

    1997-01-01

    Particle accelerators have been developed more than sixty years ago to investigate nuclear and atomic phenomena. A major shift toward applications of accelerators in the study of materials structure and composition in inter-disciplinary projects has been witnessed in the last two decades. The Australian Nuclear Science and Technology Organisation (ANSTO) has developed advanced research programs based on the use of particle and photon beams. Atmospheric pollution problems are investigated at the 3 MV Van de Graff accelerator using ion beam analysis techniques to detect toxic elements in aerosol particles. High temperature superconductor and semiconductor materials are characterised using the recoil of iodine and other heavy ions produced at ANTARES, the 10-MV Tandem accelerator. A heavy-ion microprobe is presently being developed at ANTARES to map elemental concentrations of specific elements with micro-size resolution. An Accelerator mass Spectrometry (AMS) system has been developed at ANSTO for the ultra-sensitive detection of Carbon-14, Iodine-129 and other long-lived radioisotopes. This AMS spectrometer is a key instrument for climate change studies and international safeguards. ANSTO is also managing the Australian Synchrotron Research program based on facilities developed at the Photon Factory (Japan) and at the Advanced Photon Source (USA). Advanced projects in biology, materials chemistry, structural condensed matter and other disciplines are being promoted by a consortium involving Australian universities and research institutions. This paper will review recent advances in the use of particle accelerators, with a particular emphasis on applications developed at ANSTO and related to problems of international concern, such as global environmental change, public health and nuclear proliferation

  6. Paddy field – A natural sequential anaerobic–aerobic bioreactor for polychlorinated biphenyls transformation

    International Nuclear Information System (INIS)

    Chen, Chen; Yu, Chunna; Shen, Chaofeng; Tang, Xianjin; Qin, Zhihui; Yang, Kai; Hashmi, Muhammad Zaffar; Huang, Ronglang; Shi, Huixiang

    2014-01-01

    The environmental pollution and health risks caused by the improper disposal of electric and electronic waste (e-waste) have become urgent issues for the developing countries. One of the typical pollutants, polychlorinated biphenyls (PCBs), is commonly found in farmland in Taizhou, a major hotspot of e-waste recycling in China. This study investigated the amount of PCB residue in local farmlands. Biotransformation of PCBs was further studied under different water management conditions in paddy field with or without rice cultivation, with a special focus on the alternating flooded and drying processes. It was found that paddy field improved the attenuation of PCBs, especially for highly chlorinated congeners. In the microcosm experiment, 40% or more of the initial total PCBs was removed after sequential flood–drying treatments, compared to less than 10% in the sterilized control and 20% in the constant-drying system. Variation in the quantity of PCBs degrading and dechlorinating bacterial groups were closely related to the alteration of anaerobic–aerobic conditions. These results suggested that alternating anoxic–oxic environment in paddy field led to the sequential aerobic–anaerobic transformation of PCBs, which provided a favorable environment for natural PCB attenuation. - Highlights: • Paddy fields hold significantly lower level of PCBs than drylands, especially highly-chlorinated PCBs. • Microbial dechlorination of PCBs is favored under flooded conditions in paddy field. • Aerobic biodegradation of PCBs is benefited under dry conditions in paddy field. • PCBs dechlorination rate is accelerated in rice planted paddy field compared to the unplanted one. • Alternating anoxic–oxic environment in paddy field led to the sequential aerobic–anaerobic transformation of PCBs. - Alternating anoxic–oxic environment led to the sequential aerobic–anaerobic transformation of PCBs in paddy field, which could act as a natural sequential anaerobic

  7. Critical Thinking Skill Acquisition in Accelerated LVN to RN Nursing Programs: An Evaluative Case Study

    Science.gov (United States)

    Hutchison, Billy Eugene

    2013-01-01

    Accelerated transitional nursing programs (ATNPs) designed specifically for licensed vocational nurses (LVNs) to transition to become registered nurses (RNs) are graduating novice nurses who need critical thinking skills to solve patient problems. The health care industry and patient outcomes depend on graduate nurses to be proficient with quality…

  8. FMIT accelerator

    International Nuclear Information System (INIS)

    Armstrong, D.D.

    1983-01-01

    A 35-MeV 100-mA cw linear accelerator is being designed by Los Alamos for use in the Fusion Materials Irradiation Test (FMIT) Facility. Essential to this program is the design, construction, and evaluation of performance of the accelerator's injector, low-energy beam transport, and radio-frequency quadrupole sections before they are shipped to the facility site. The installation and testing of some of these sections have begun as well as the testing of the rf, noninterceptive beam diagnostics, computer control, dc power, and vacuum systems. An overview of the accelerator systems and the performance to date is given

  9. Final Report to the Department of Energy on the 1994 International Accelerator School: Frontiers of Accelerator Technology; FINAL

    International Nuclear Information System (INIS)

    Harris, F.A.

    1998-01-01

    The international accelerator school on Frontiers of Accelerator Technology was organized jointly by the US Particle Accelerator School (Dr. Mel Month and Ms. Marilyn Paul), the CERN Accelerator School, and the KEK Accelerator School, and was hosted by the University of Hawaii. The course was held on Maui, Hawaii, November 3-9, 1994 and was made possible in part by a grant from the Department of Energy under award number DE-FG03-94ER40875, AMDT M006. The 1994 program was preceded by similar joint efforts held at Santa Margherita di Pula, Sardinia in February 1985, South Padre Island, Texas in October 1986, Anacapri, Italy in October 1988, Hilton Head Island, South Carolina in October 1990, and Benalmedena, Spain in October/November 1992. The most recent program was held in Montreux, Switzerland in May 1998. The purpose of the program is to disseminate knowledge on the latest ideas and developments in the technology of particle accelerators by bringing together known world experts and younger scientists in the field. It is intended for individuals with professional interest in accelerator physics and technology, for graduate students, for post-docs, for those interested in accelerator based sciences, and for scientific and engineering staff at industrial firms, especially those companies specializing in accelerator components

  10. 2014 CERN Accelerator Schools: Beam Loss and Accelerator Protection

    CERN Multimedia

    2014-01-01

    The US-CERN-JAPAN-RUSSIA Joint International Accelerator School is organising a course on Beam Loss and Accelerator Protection to be held in Newport Beach, California, USA from 5-14 November, 2014.    This school is intended for physicists and engineers who are or may be engaged in the design, construction, and/or operation of accelerators with high power photon or particle beams and/or accelerator sub-systems with large stored energy. Application deadlines are 15 August and 4 September. Further information on this Joint School can be found at: http://cas.web.cern.ch/cas/JAS/Newport%20Beach%202014/NPBadvert.html http://indico.cern.ch/event/287647/ http://uspas.fnal.gov/programs/JAS/JAS14.shtml

  11. Monte Carlo Tree Search for Continuous and Stochastic Sequential Decision Making Problems

    International Nuclear Information System (INIS)

    Couetoux, Adrien

    2013-01-01

    In this thesis, I studied sequential decision making problems, with a focus on the unit commitment problem. Traditionally solved by dynamic programming methods, this problem is still a challenge, due to its high dimension and to the sacrifices made on the accuracy of the model to apply state of the art methods. I investigated on the applicability of Monte Carlo Tree Search methods for this problem, and other problems that are single player, stochastic and continuous sequential decision making problems. In doing so, I obtained a consistent and anytime algorithm, that can easily be combined with existing strong heuristic solvers. (author)

  12. Accelerator safety program at the Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Graham, C.L.

    1976-01-01

    A proposed accelerator safety standard for the Lawrence Livermore Laboratory (LLL) is given. All accelerators will comply with this standard when it is included in the LLL Health and Safety Manual. The radiation alarm and radiation safety system for a radiography facility are also described

  13. Steady-State Anderson Accelerated Coupling of Lattice Boltzmann and Navier–Stokes Solvers

    KAUST Repository

    Atanasov, Atanas

    2016-10-17

    We present an Anderson acceleration-based approach to spatially couple three-dimensional Lattice Boltzmann and Navier–Stokes (LBNS) flow simulations. This allows to locally exploit the computational features of both fluid flow solver approaches to the fullest extent and yields enhanced control to match the LB and NS degrees of freedom within the LBNS overlap layer. Designed for parallel Schwarz coupling, the Anderson acceleration allows for the simultaneous execution of both Lattice Boltzmann and Navier–Stokes solver. We detail our coupling methodology, validate it, and study convergence and accuracy of the Anderson accelerated coupling, considering three steady-state scenarios: plane channel flow, flow around a sphere and channel flow across a porous structure. We find that the Anderson accelerated coupling yields a speed-up (in terms of iteration steps) of up to 40% in the considered scenarios, compared to strictly sequential Schwarz coupling.

  14. Combining Compact Representation and Incremental Generation in Large Games with Sequential Strategies

    DEFF Research Database (Denmark)

    Bosansky, Branislav; Xin Jiang, Albert; Tambe, Milind

    2015-01-01

    representation of sequential strategies and linear programming, or by incremental strategy generation of iterative double-oracle methods. In this paper, we present novel hybrid of these two approaches: compact-strategy double-oracle (CS-DO) algorithm that combines the advantages of the compact representation...

  15. Sequential lineup laps and eyewitness accuracy.

    Science.gov (United States)

    Steblay, Nancy K; Dietrich, Hannah L; Ryan, Shannon L; Raczynski, Jeanette L; James, Kali A

    2011-08-01

    Police practice of double-blind sequential lineups prompts a question about the efficacy of repeated viewings (laps) of the sequential lineup. Two laboratory experiments confirmed the presence of a sequential lap effect: an increase in witness lineup picks from first to second lap, when the culprit was a stranger. The second lap produced more errors than correct identifications. In Experiment 2, lineup diagnosticity was significantly higher for sequential lineup procedures that employed a single versus double laps. Witnesses who elected to view a second lap made significantly more errors than witnesses who chose to stop after one lap or those who were required to view two laps. Witnesses with prior exposure to the culprit did not exhibit a sequential lap effect.

  16. Wandering accelerators throughout my life (1)

    International Nuclear Information System (INIS)

    Nakai, Kozi

    2009-01-01

    My wanderings about accelerators started being stimulated by nuclear physics activities of the Kikuchi Laboratory in Osaka University. When the university was founded in 1931, President Nagaoka put emphasis on the nuclear physics programs and called Professor Kikuchi to establish a center of nuclear physics. Since then the laboratory successfully cultivated the new field through studies of the neutron-nucleus interactions with a Cockcroft-Walton accelerator, the beta-decay study with a Cyclotron before the World-War II. Those accelerators were all home made, including the second cyclotron built after the war. Through such experimental programs, the Kikuchi Laboratory brought up many talented physicists in accelerator and nuclear science. (author)

  17. Robustness of the Sequential Lineup Advantage

    Science.gov (United States)

    Gronlund, Scott D.; Carlson, Curt A.; Dailey, Sarah B.; Goodsell, Charles A.

    2009-01-01

    A growing movement in the United States and around the world involves promoting the advantages of conducting an eyewitness lineup in a sequential manner. We conducted a large study (N = 2,529) that included 24 comparisons of sequential versus simultaneous lineups. A liberal statistical criterion revealed only 2 significant sequential lineup…

  18. The Soreq Applied Research Accelerator Facility (SARAF): Overview, research programs and future plans

    Science.gov (United States)

    Mardor, Israel; Aviv, Ofer; Avrigeanu, Marilena; Berkovits, Dan; Dahan, Adi; Dickel, Timo; Eliyahu, Ilan; Gai, Moshe; Gavish-Segev, Inbal; Halfon, Shlomi; Hass, Michael; Hirsh, Tsviki; Kaiser, Boaz; Kijel, Daniel; Kreisel, Arik; Mishnayot, Yonatan; Mukul, Ish; Ohayon, Ben; Paul, Michael; Perry, Amichay; Rahangdale, Hitesh; Rodnizki, Jacob; Ron, Guy; Sasson-Zukran, Revital; Shor, Asher; Silverman, Ido; Tessler, Moshe; Vaintraub, Sergey; Weissman, Leo

    2018-05-01

    The Soreq Applied Research Accelerator Facility (SARAF) is under construction in the Soreq Nuclear Research Center at Yavne, Israel. When completed at the beginning of the next decade, SARAF will be a user facility for basic and applied nuclear physics, based on a 40 MeV, 5 mA CW proton/deuteron superconducting linear accelerator. Phase I of SARAF (SARAF-I, 4 MeV, 2 mA CW protons, 5 MeV 1 mA CW deuterons) is already in operation, generating scientific results in several fields of interest. The main ongoing program at SARAF-I is the production of 30 keV neutrons and measurement of Maxwellian Averaged Cross Sections (MACS), important for the astrophysical s-process. The world leading Maxwellian epithermal neutron yield at SARAF-I (5 × 10^{10} epithermal neutrons/s), generated by a novel Liquid-Lithium Target (LiLiT), enables improved precision of known MACSs, and new measurements of low-abundance and radioactive isotopes. Research plans for SARAF-II span several disciplines: precision studies of beyond-Standard-Model effects by trapping light exotic radioisotopes, such as 6He, 8Li and 18, 19, 23Ne, in unprecedented amounts (including meaningful studies already at SARAF-I); extended nuclear astrophysics research with higher energy neutrons, including generation and studies of exotic neutron-rich isotopes relevant to the rapid (r-) process; nuclear structure of exotic isotopes; high energy neutron cross sections for basic nuclear physics and material science research, including neutron induced radiation damage; neutron based imaging and therapy; and novel radiopharmaceuticals development and production. In this paper we present a technical overview of SARAF-I and II, including a description of the accelerator and its irradiation targets; a survey of existing research programs at SARAF-I; and the research potential at the completed facility (SARAF-II).

  19. Collective acceleration investigations with the ionization front accelerator

    International Nuclear Information System (INIS)

    Olson, C.L.; Poukey, J.W.; VanDevender, J.P.; Owyoung, A.; Pearlman, J.S.

    1977-01-01

    Part I of a three part program to demonstrate feasibility of the Ionization Front Accelerator (IFA) has been completed and is successful. Experiments describing intense relativistic electron beam (IREB) propagation in Cs are reported. The threshold pressure for electron beam ionization of Cs is found to agree with earlier theoretical predictions. These results experimentally establish Cs as a feasible working gas for the IFA. Numerical simulation results are also reported which demonstrate controlled potential well motion and collective ion acceleration with the IFA

  20. The Impact of Prematriculation Admission Characteristics on Graduation Rates in an Accelerated Doctor of Pharmacy Program.

    Science.gov (United States)

    Steinberg, Michael; Morin, Anna K

    2015-10-25

    Objective. To evaluate the impact of admission characteristics on graduation in an accelerated doctor of pharmacy (PharmD) program. Methods. Selected prematriculation characteristics of students entering the graduation class years of 2009-2012 on the Worcester and Manchester campuses of MCPHS University were analyzed and compared for on-time graduation. Results. Eighty-two percent of evaluated students (699 of 852) graduated on time. Students who were most likely to graduate on-time attended a 4-year school, previously earned a bachelor's degree, had an overall prematriculation grade point average (GPA) greater than or equal to 3.6, and graduated in the spring just prior to matriculating to the university. Factors that reduced the likelihood of graduating on time were also identified. Work experience had a marginal impact on graduating on time. Conclusion. Although there is no certainty in college admission decisions, prematriculation characteristics can help predict the likelihood for academic success of students in an accelerated PharmD program.

  1. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.; Shamma, Jeff S.

    2014-01-01

    incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well

  2. Interactive Design of Accelerators (IDA)

    International Nuclear Information System (INIS)

    Barton, M.Q.

    1987-01-01

    IDA is a beam transport line calculation program which runs interactively on an IBM PC computer. It can be used for a large fraction of the usual calculations done for beam transport systems or periods of accelerators or storage rings. Because of the interactive screen editor nature of the data input, this program permits one to rather quickly arrive at general properties of a beam line or an accelerator period

  3. Sequential stochastic optimization

    CERN Document Server

    Cairoli, Renzo

    1996-01-01

    Sequential Stochastic Optimization provides mathematicians and applied researchers with a well-developed framework in which stochastic optimization problems can be formulated and solved. Offering much material that is either new or has never before appeared in book form, it lucidly presents a unified theory of optimal stopping and optimal sequential control of stochastic processes. This book has been carefully organized so that little prior knowledge of the subject is assumed; its only prerequisites are a standard graduate course in probability theory and some familiarity with discrete-paramet

  4. Accelerator Technology Program. Status report, January-September 1983

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1984-07-01

    This report presents highlights of major projects in the Accelerator Technology Division of the Los Alamos National Laboratory. The first section deals with the Fusion Materials Irradiation Test Facility's 2-MeV accelerator on which tests began in May, as scheduled. Then, activities are reported on beam dynamics, inertial fusion, structure development, the racetrack microtron, the CERN high-energy physics experiment NA-12, and LAMPF II. The Proton Storage Ring is discussed next, with emphasis on the computer control system, diagnostics interfacing, and theoretical support. Other sections summarize progress on a portable radiographic linac, developments on the klystron code, and on permanent magnets. Activities of the Theory and Simulation Group are outlined next, followed by discussion of the oscillator experiment and the energy-recovery experiment in the free electron laser project. The last section reports on the accelerator test stand. An unusual and very satisfying activity for the Division was the hosting of the 1983 Particle Accelerator Conference in Santa Fe, March 21-23, 1983. The conference had the largest attendance ever, with 895 registrants, 61 invited papers, and 521 contributed papers

  5. Introduction of Parallel GPGPU Acceleration Algorithms for the Solution of Radiative Transfer

    Science.gov (United States)

    Godoy, William F.; Liu, Xu

    2011-01-01

    General-purpose computing on graphics processing units (GPGPU) is a recent technique that allows the parallel graphics processing unit (GPU) to accelerate calculations performed sequentially by the central processing unit (CPU). To introduce GPGPU to radiative transfer, the Gauss-Seidel solution of the well-known expressions for 1-D and 3-D homogeneous, isotropic media is selected as a test case. Different algorithms are introduced to balance memory and GPU-CPU communication, critical aspects of GPGPU. Results show that speed-ups of one to two orders of magnitude are obtained when compared to sequential solutions. The underlying value of GPGPU is its potential extension in radiative solvers (e.g., Monte Carlo, discrete ordinates) at a minimal learning curve.

  6. Accelerator research studies

    International Nuclear Information System (INIS)

    1992-01-01

    The Accelerator Research Studies program at the University of Maryland, sponsored by the Department of Energy under grant number DE-FG05-91ER40642, is currently in the first year of a three-year funding cycle. The program consists of the following three tasks: TASK A, Study of Transport and Longitudinal Compression of Intense, High-Brightness Beams, TASK B, Study of Collective Ion Acceleration by Intense Electron Beams and Pseudospark Produced High Brightness Electron Beams; TASK C, Study of a Gyroklystron High-power Microwave Source for Linear Colliders. In this report we document the progress that has been made during the past year for each of the three tasks

  7. Exploring the sequential lineup advantage using WITNESS.

    Science.gov (United States)

    Goodsell, Charles A; Gronlund, Scott D; Carlson, Curt A

    2010-12-01

    Advocates claim that the sequential lineup is an improvement over simultaneous lineup procedures, but no formal (quantitatively specified) explanation exists for why it is better. The computational model WITNESS (Clark, Appl Cogn Psychol 17:629-654, 2003) was used to develop theoretical explanations for the sequential lineup advantage. In its current form, WITNESS produced a sequential advantage only by pairing conservative sequential choosing with liberal simultaneous choosing. However, this combination failed to approximate four extant experiments that exhibited large sequential advantages. Two of these experiments became the focus of our efforts because the data were uncontaminated by likely suspect position effects. Decision-based and memory-based modifications to WITNESS approximated the data and produced a sequential advantage. The next step is to evaluate the proposed explanations and modify public policy recommendations accordingly.

  8. The facilitators and barriers to nurses' participation in continuing education programs: a mixed method explanatory sequential study.

    Science.gov (United States)

    Shahhosseini, Zohreh; Hamzehgardeshi, Zeinab

    2014-11-30

    Since several factors affect nurses' participation in Continuing Education, and that nurses' Continuing Education affects patients' and community health status, it is essential to know facilitators and barriers of participation in Continuing Education programs and plan accordingly. This mixed approach study aimed to investigate the facilitators and barriers of nurses' participation, to explore nurses' perception of the most common facilitators and barriers. An explanatory sequential mixed methods design with follow up explanations variant were used, and it involved collecting quantitative data (361 nurses) first and then explaining the quantitative results with in-depth interviews during a qualitative study. The results showed that the mean score of facilitators to nurses' participation in Continuing Education was significantly higher than the mean score of barriers (61.99 ± 10.85 versus 51.17 ± 12.83; pEducation was related to "Update my knowledge". By reviewing the handwritings in qualitative phase, two main levels of updating information and professional skills were extracted as the most common facilitators and lack of support as the most common barrier to nurses' participation in continuing education program. According to important role Continuing Education on professional skills, nurse managers should facilitate the nurse' participation in the Continues Education.

  9. Sequential memory: Binding dynamics

    Science.gov (United States)

    Afraimovich, Valentin; Gong, Xue; Rabinovich, Mikhail

    2015-10-01

    Temporal order memories are critical for everyday animal and human functioning. Experiments and our own experience show that the binding or association of various features of an event together and the maintaining of multimodality events in sequential order are the key components of any sequential memories—episodic, semantic, working, etc. We study a robustness of binding sequential dynamics based on our previously introduced model in the form of generalized Lotka-Volterra equations. In the phase space of the model, there exists a multi-dimensional binding heteroclinic network consisting of saddle equilibrium points and heteroclinic trajectories joining them. We prove here the robustness of the binding sequential dynamics, i.e., the feasibility phenomenon for coupled heteroclinic networks: for each collection of successive heteroclinic trajectories inside the unified networks, there is an open set of initial points such that the trajectory going through each of them follows the prescribed collection staying in a small neighborhood of it. We show also that the symbolic complexity function of the system restricted to this neighborhood is a polynomial of degree L - 1, where L is the number of modalities.

  10. An Annotated Bibliography of Accelerated Learning

    Science.gov (United States)

    Garcia, GNA

    2007-01-01

    A rich narrative-style bibliography of accelerated learning (reviewing six articles published between 1995-2003). Articles reviewed include: (1) Accelerative learning and the Emerging Science of Wholeness (D. D. Beale); (2) Effective Teaching in Accelerated Learning Programs (D. Boyd); (3) A Critical Theory Perspective on Accelerated Learning (S.…

  11. Sequential multi-nuclide emission rate estimation method based on gamma dose rate measurement for nuclear emergency management

    International Nuclear Information System (INIS)

    Zhang, Xiaole; Raskob, Wolfgang; Landman, Claudia; Trybushnyi, Dmytro; Li, Yu

    2017-01-01

    Highlights: • Sequentially reconstruct multi-nuclide emission using gamma dose rate measurements. • Incorporate a priori ratio of nuclides into the background error covariance matrix. • Sequentially augment and update the estimation and the background error covariance. • Suppress the generation of negative estimations for the sequential method. • Evaluate the new method with twin experiments based on the JRODOS system. - Abstract: In case of a nuclear accident, the source term is typically not known but extremely important for the assessment of the consequences to the affected population. Therefore the assessment of the potential source term is of uppermost importance for emergency response. A fully sequential method, derived from a regularized weighted least square problem, is proposed to reconstruct the emission and composition of a multiple-nuclide release using gamma dose rate measurement. The a priori nuclide ratios are incorporated into the background error covariance (BEC) matrix, which is dynamically augmented and sequentially updated. The negative estimations in the mathematical algorithm are suppressed by utilizing artificial zero-observations (with large uncertainties) to simultaneously update the state vector and BEC. The method is evaluated by twin experiments based on the JRodos system. The results indicate that the new method successfully reconstructs the emission and its uncertainties. Accurate a priori ratio accelerates the analysis process, which obtains satisfactory results with only limited number of measurements, otherwise it needs more measurements to generate reasonable estimations. The suppression of negative estimation effectively improves the performance, especially for the situation with poor a priori information, where it is more prone to the generation of negative values.

  12. Sequential multi-nuclide emission rate estimation method based on gamma dose rate measurement for nuclear emergency management

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiaole, E-mail: zhangxiaole10@outlook.com [Institute for Nuclear and Energy Technologies, Karlsruhe Institute of Technology, Karlsruhe, D-76021 (Germany); Institute of Public Safety Research, Department of Engineering Physics, Tsinghua University, Beijing, 100084 (China); Raskob, Wolfgang; Landman, Claudia; Trybushnyi, Dmytro; Li, Yu [Institute for Nuclear and Energy Technologies, Karlsruhe Institute of Technology, Karlsruhe, D-76021 (Germany)

    2017-03-05

    Highlights: • Sequentially reconstruct multi-nuclide emission using gamma dose rate measurements. • Incorporate a priori ratio of nuclides into the background error covariance matrix. • Sequentially augment and update the estimation and the background error covariance. • Suppress the generation of negative estimations for the sequential method. • Evaluate the new method with twin experiments based on the JRODOS system. - Abstract: In case of a nuclear accident, the source term is typically not known but extremely important for the assessment of the consequences to the affected population. Therefore the assessment of the potential source term is of uppermost importance for emergency response. A fully sequential method, derived from a regularized weighted least square problem, is proposed to reconstruct the emission and composition of a multiple-nuclide release using gamma dose rate measurement. The a priori nuclide ratios are incorporated into the background error covariance (BEC) matrix, which is dynamically augmented and sequentially updated. The negative estimations in the mathematical algorithm are suppressed by utilizing artificial zero-observations (with large uncertainties) to simultaneously update the state vector and BEC. The method is evaluated by twin experiments based on the JRodos system. The results indicate that the new method successfully reconstructs the emission and its uncertainties. Accurate a priori ratio accelerates the analysis process, which obtains satisfactory results with only limited number of measurements, otherwise it needs more measurements to generate reasonable estimations. The suppression of negative estimation effectively improves the performance, especially for the situation with poor a priori information, where it is more prone to the generation of negative values.

  13. Accelerating the commercialization on new technologies. [free market operation of federal alternate energy sources programs

    Science.gov (United States)

    Kuehn, T. J.; Nawrocki, P. M.

    1978-01-01

    It is suggested that federal programs for hastening the adoption of alternative energy sources must operate within the free market structure. Five phases of the free market commercialization process are described. Federal role possibilities include information dissemination and funding to stimulate private sector activities within these five phases, and federally sponsored procedures for accelerating commercialization of solar thermal small power systems are considered.

  14. Sequential Probability Ration Tests : Conservative and Robust

    NARCIS (Netherlands)

    Kleijnen, J.P.C.; Shi, Wen

    2017-01-01

    In practice, most computers generate simulation outputs sequentially, so it is attractive to analyze these outputs through sequential statistical methods such as sequential probability ratio tests (SPRTs). We investigate several SPRTs for choosing between two hypothesized values for the mean output

  15. Nuclear physics accelerator facilities

    International Nuclear Information System (INIS)

    1988-12-01

    This paper describes many of the nuclear physics heavy-ion accelerator facilities in the US and the research programs being conducted. The accelerators described are: Argonne National Laboratory--ATLAS; Brookhaven National Laboratory--Tandem/AGS Heavy Ion Facility; Brookhaven National Laboratory--Relativistic Heavy Ion Collider (RHIC) (Proposed); Continuous Electron Beam Accelerator Facility; Lawrence Berkeley Laboratory--Bevalac; Lawrence Berkeley Laboratory--88-Inch Cyclotron; Los Alamos National Laboratory--Clinton P. Anderson Meson Physics Facility (LAMPF); Massachusetts Institute of Technology--Bates Linear Accelerator Center; Oak Ridge National Laboratory--Holifield Heavy Ion Research Facility; Oak Ridge National Laboratory--Oak Ridge Electron Linear Accelerator; Stanford Linear Accelerator Center--Nuclear Physics Injector; Texas AandM University--Texas AandM Cyclotron; Triangle Universities Nuclear Laboratory (TUNL); University of Washington--Tandem/Superconducting Booster; and Yale University--Tandem Van de Graaff

  16. Accelerator for nuclear transmutation

    International Nuclear Information System (INIS)

    Schapira, J.P.

    1984-01-01

    A review on nuclear transmutation of radioactive wastes using particle accelerators is given. Technical feasibility, nuclear data, costs of various projects are discussed. It appears that one high energy accelerator (1500 MeV, 300 mA proton) could probably handle the amount of actinides generated by the actual French nuclear program [fr

  17. Effects of Video Game-Based Instruction on Writing Achievement and Motivation in Postsecondary Accelerated Degree Programs

    Science.gov (United States)

    Lee, Michael C.

    2017-01-01

    The purpose of this quantitative experimental posttest-only control group research study was to determine the degree to which differences exist in outcomes between students using a video game-based instruction and students using a traditional non-video game-based instruction in accelerated degree program courses at a 4-year university in Illinois…

  18. Accelerators for heavy ion inertial fusion: Progress and plans

    International Nuclear Information System (INIS)

    Bangerter, R.O.; Friedman, A.; Herrmannsfeldt, W.B.

    1994-08-01

    The Heavy Ion Inertial Fusion Program is the principal part of the Inertial Fusion Energy Program in the Office of Fusion Energy of the U.S. Department of Energy. The emphasis of the Heavy Ion Program is the development of accelerators for fusion power production. Target physics research and some elements of fusion chamber development are supported in the much larger Inertial Confinement Fusion Program, a dual purpose (defense and energy) program in the Defense Programs part of the Department of Energy. The accelerator research program will establish feasibility through a sequence of scaled experiments that will demonstrate key physics and engineering issues at low cost compared to other fusion programs. This paper discusses progress in the accelerator program and outlines how the planned research will address the key economic issues of inertial fusion energy

  19. Symposium on accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-01-01

    The area of accelerator mass spectrometry has expanded considerably over the past few years and established itself as an independent and interdisciplinary research field. Three years have passed since the first meeting was held at Rochester. A Symposium on Accelerator Mass Spectrometry was held at Argonne on May 11-13, 1981. In attendance were 96 scientists of whom 26 were from outside the United States. The present proceedings document the program and excitement of the field. Papers are arranged according to the original program. A few papers not presented at the meeting have been added to complete the information on the status of accelerator mass spectrometry. Individual papers were prepared separately for the data base.

  20. Symposium on accelerator mass spectrometry

    International Nuclear Information System (INIS)

    1981-01-01

    The area of accelerator mass spectrometry has expanded considerably over the past few years and established itself as an independent and interdisciplinary research field. Three years have passed since the first meeting was held at Rochester. A Symposium on Accelerator Mass Spectrometry was held at Argonne on May 11-13, 1981. In attendance were 96 scientists of whom 26 were from outside the United States. The present proceedings document the program and excitement of the field. Papers are arranged according to the original program. A few papers not presented at the meeting have been added to complete the information on the status of accelerator mass spectrometry. Individual papers were prepared separately for the data base

  1. Status of accelerator development at Fermilab

    International Nuclear Information System (INIS)

    Owen, C.W.

    1976-01-01

    The Fermilab accelerator is comprised of four major systems: the high-energy beam-extraction and switching system, the main accelerator (main ring), the booster, and the linear accelerator. The Fermilab accelerator produces accelerated beams for a vigorous international high-energy physics program. The basic design features and operation for high-energy physics have been described a number of times in the past. A report is given which, for the most part, discusses in detail only those features that are particularly significant in increasing the usefulness of the accelerator as a tool for high-energy physics

  2. Sequential lineup presentation: Patterns and policy

    OpenAIRE

    Lindsay, R C L; Mansour, Jamal K; Beaudry, J L; Leach, A-M; Bertrand, M I

    2009-01-01

    Sequential lineups were offered as an alternative to the traditional simultaneous lineup. Sequential lineups reduce incorrect lineup selections; however, the accompanying loss of correct identifications has resulted in controversy regarding adoption of the technique. We discuss the procedure and research relevant to (1) the pattern of results found using sequential versus simultaneous lineups; (2) reasons (theory) for differences in witness responses; (3) two methodological issues; and (4) im...

  3. Sequential Product of Quantum Effects: An Overview

    Science.gov (United States)

    Gudder, Stan

    2010-12-01

    This article presents an overview for the theory of sequential products of quantum effects. We first summarize some of the highlights of this relatively recent field of investigation and then provide some new results. We begin by discussing sequential effect algebras which are effect algebras endowed with a sequential product satisfying certain basic conditions. We then consider sequential products of (discrete) quantum measurements. We next treat transition effect matrices (TEMs) and their associated sequential product. A TEM is a matrix whose entries are effects and whose rows form quantum measurements. We show that TEMs can be employed for the study of quantum Markov chains. Finally, we prove some new results concerning TEMs and vector densities.

  4. Optimal Sequential Rules for Computer-Based Instruction.

    Science.gov (United States)

    Vos, Hans J.

    1998-01-01

    Formulates sequential rules for adapting the appropriate amount of instruction to learning needs in the context of computer-based instruction. Topics include Bayesian decision theory, threshold and linear-utility structure, psychometric model, optimal sequential number of test questions, and an empirical example of sequential instructional…

  5. Illinois Accelerator Research Center

    Science.gov (United States)

    Kroc, Thomas K.; Cooper, Charlie A.

    The Illinois Accelerator Research Center (IARC) hosts a new accelerator development program at Fermi National Accelerator Laboratory. IARC provides access to Fermi's state-of-the-art facilities and technologies for research, development and industrialization of particle accelerator technology. In addition to facilitating access to available existing Fermi infrastructure, the IARC Campus has a dedicated 36,000 ft2 Heavy Assembly Building (HAB) with all the infrastructure needed to develop, commission and operate new accelerators. Connected to the HAB is a 47,000 ft2 Office, Technology and Engineering (OTE) building, paid for by the state, that has office, meeting, and light technical space. The OTE building, which contains the Accelerator Physics Center, and nearby Accelerator and Technical divisions provide IARC collaborators with unique access to world class expertise in a wide array of accelerator technologies. At IARC scientists and engineers from Fermilab and academia work side by side with industrial partners to develop breakthroughs in accelerator science and translate them into applications for the nation's health, wealth and security.

  6. Developing an environmental compliance program for accelerator production of tritium

    International Nuclear Information System (INIS)

    Reynolds, R.W.; Roberts, J.S.; Dyer, K.W.; Shedrow, C.B.; Sheetz, S.O.; England, J.L.

    1998-01-01

    This paper addresses the development of an environmental program for a large proposed federal project currently in the preliminary design phase, namely, the accelerator production of tritium (APT) for the US Department of Energy (DOE). This project is complicated not only by its size ($3.5 to $4.5 billion) but also by its technical complexity and one-of-a-kind nature. This is further complicated by the fact that government projects are driven by budgets subject to public pressures and annual Congressional fiscal considerations, whereas private companies are driven by profits. The measure of success for a federal project such as the APT is based on level of public support, not profits. Finally, there are not too many equivalent environmental programs that could be used as models, and benchmarking is nearly impossible. Forming an environmental program during the conceptual design phase of this large federal project included the formation of a core environmental working group (EWG). The group has membership from all major project organizations with a charter formally recognized by the project director. The envelope for traditional environmental work for the APT project has been stretched to include teaming with management in the establishment of project goals and direction. The APT EWG was set up organizationally to include several subgroups or teams that do the real work of assessing, establishing the regulatory framework, and then developing a compliance program. Setting aside the organizational difficulties of selecting the right team leads and members, each team was tasked with developing a charter, plan, and schedule. Since then, each team has developed an appropriate level of supporting documentation to address its particular issues and requirements

  7. Tandem accelerators, 1973--1974

    International Nuclear Information System (INIS)

    Howard, F.T.

    1974-01-01

    High voltage tandem accelerators are very important instruments in the field of nuclear physics research, especially in the acceleration of heavy ions. This survey identifies 77 tandems installed in 21 countries; of these, 34 are in the United States. Most installations have supplied data sheets identifying their machines and briefly characterizing their research programs. (U.S.)

  8. Quantum Inequalities and Sequential Measurements

    International Nuclear Information System (INIS)

    Candelpergher, B.; Grandouz, T.; Rubinx, J.L.

    2011-01-01

    In this article, the peculiar context of sequential measurements is chosen in order to analyze the quantum specificity in the two most famous examples of Heisenberg and Bell inequalities: Results are found at some interesting variance with customary textbook materials, where the context of initial state re-initialization is described. A key-point of the analysis is the possibility of defining Joint Probability Distributions for sequential random variables associated to quantum operators. Within the sequential context, it is shown that Joint Probability Distributions can be defined in situations where not all of the quantum operators (corresponding to random variables) do commute two by two. (authors)

  9. Innovating in health care management education: development of an accelerated MBA and MPH degree program at Yale.

    Science.gov (United States)

    Pettigrew, Melinda M; Forman, Howard P; Pistell, Anne F; Nembhard, Ingrid M

    2015-03-01

    Increasingly, there is recognition of the need for individuals with expertise in both management and public health to help health care organizations deliver high-quality and cost-effective care. The Yale School of Public Health and Yale School of Management began offering an accelerated Master of Business Administration (MBA) and Master of Public Health (MPH) joint degree program in the summer of 2014. This new program enables students to earn MBA and MPH degrees simultaneously from 2 fully accredited schools in 22 months. Students will graduate with the knowledge and skills needed to become innovative leaders of health care organizations. We discuss the rationale for the program, the developmental process, the curriculum, benefits of the program, and potential challenges.

  10. A Practical Framework for Evaluating Health Services Management Educational Program: The Application of The Mixed-Method Sequential Explanatory Design

    Directory of Open Access Journals (Sweden)

    Bazrafshan Azam

    2015-07-01

    Full Text Available Introduction:Health services managers are responsible for improving the efficiency and quality in delivering healthcare services. In this regard, Health Services Management (HSM programs have been widely established to provide health providers with skilled, professional managers to address those needs. It is therefore important to ascertain the quality of these programs. The purpose of this study was to synthesize and develop a framework to evaluate the quality of the Health Services Management (HSM program at Kerman University of Medical Sciences. Methods: This study followed a mixed-method sequential explanatory approach in which data were collected through a CIPP survey and semi-structured interviews. In phase 1, participants included 10 faculty members, 64 students and 90 alumni. In phase 2, in-depth semi-structured interviews and purposeful sampling were conducted with 27 participants to better understand their perceptions of the HSM program. All interviews were audio-taped and transcribed verbatim. NVivo N8 was used to analyze the qualitative data and extract the themes. Results: The data analysis revealed both positive and negative attitudes toward the HSM program. According to the CIPP survey, program objectives (74%, curriculum content (59.5% and graduate skills (79% were the major sources of dissatisfaction. However, most respondents (n=48 reported that the classes are well equipped and learning resources are well prepared (n=41. Most respondents (n=41 reported that the students are actively involved in classroom activities. The majority of respondents (n=43 pointed out that the instructors implemented appropriate teaching strategies. Qualitative analysis of interviews revealed that a regular community needs assessment, content revision and directing attention to graduate skills and expertise are the key solutions to improve the program’s quality.Conclusion: This study revealed to what extent the HSM program objectives is being

  11. Sequential optimization of approximate inhibitory rules relative to the length, coverage and number of misclassifications

    KAUST Repository

    Alsolami, Fawaz; Chikalov, Igor; Moshkov, Mikhail

    2013-01-01

    This paper is devoted to the study of algorithms for sequential optimization of approximate inhibitory rules relative to the length, coverage and number of misclassifications. Theses algorithms are based on extensions of dynamic programming approach

  12. Effects of a self-management education program on self-efficacy in patients with COPD: a mixed-methods sequential explanatory designed study

    Science.gov (United States)

    Ng, Wai I; Smith, Graeme Drummond

    2017-01-01

    Background Self-management education programs (SMEPs) are potentially effective in the symptomatic management of COPD. Little is presently known about the effectiveness of these programs in Chinese COPD patients. The objective of this study was to evaluate the effectiveness of a specifically designed SMEP on levels of self-efficacy in Chinese patients with COPD. Materials and methods Based on the Medical Research Council framework for evaluating complex interventions, an exploratory phase randomized controlled trial was employed to examine the effects of an SMEP. Self-efficacy was the primary outcome using the COPD Self-efficacy Scale, measured at baseline and 6 months after the program. Qualitative data were sequentially collected from these patients via three focus groups to supplement the quantitative findings. Results The experimental group displayed significant improvement in their general self-efficacy (Z =−2.44, P=0.015) and specifically in confronting 1) physical exertion (Z =−2.57, P=0.01), 2) weather/environment effects (Z =−2.63, PChinese patients with COPD. Further attention should be given to cultural considerations when developing this type of intervention in Chinese populations with COPD and other chronic diseases. PMID:28790816

  13. A Global Review of Incentive Programs to Accelerate Energy-Efficient Appliances and Equipment

    Energy Technology Data Exchange (ETDEWEB)

    de la Rue du Can, Stephane; Phadke, Amol; Leventis, Greg; Gopal, Anand

    2013-08-01

    Incentive programs are an essential policy tool to move the market toward energy-efficient products. They offer a favorable complement to mandatory standards and labeling policies by accelerating the market penetration of energy-efficient products above equipment standard requirements and by preparing the market for increased future mandatory requirements. They sway purchase decisions and in some cases production decisions and retail stocking decisions toward energy-efficient products. Incentive programs are structured according to their regulatory environment, the way they are financed, by how the incentive is targeted, and by who administers them. This report categorizes the main elements of incentive programs, using case studies from the Major Economies Forum to illustrate their characteristics. To inform future policy and program design, it seeks to recognize design advantages and disadvantages through a qualitative overview of the variety of programs in use around the globe. Examples range from rebate programs administered by utilities under an Energy-Efficiency Resource Standards (EERS) regulatory framework (California, USA) to the distribution of Eco-Points that reward customers for buying efficient appliances under a government recovery program (Japan). We found that evaluations have demonstrated that financial incentives programs have greater impact when they target highly efficient technologies that have a small market share. We also found that the benefits and drawbacks of different program design aspects depend on the market barriers addressed, the target equipment, and the local market context and that no program design surpasses the others. The key to successful program design and implementation is a thorough understanding of the market and effective identification of the most important local factors hindering the penetration of energy-efficient technologies.

  14. Collective ion acceleration

    International Nuclear Information System (INIS)

    Godfrey, B.B.; Faehl, R.J.; Newberger, B.S.; Shanahan, W.R.; Thode, L.E.

    1977-01-01

    Progress achieved in the understanding and development of collective ion acceleration is presented. Extensive analytic and computational studies of slow cyclotron wave growth on an electron beam in a helix amplifier were performed. Research included precise determination of linear coupling between beam and helix, suppression of undesired transients and end effects, and two-dimensional simulations of wave growth in physically realizable systems. Electrostatic well depths produced exceed requirements for the Autoresonant Ion Acceleration feasibility experiment. Acceleration of test ions to modest energies in the troughs of such waves was also demonstrated. Smaller efforts were devoted to alternative acceleration mechanisms. Langmuir wave phase velocity in Converging Guide Acceleration was calculated as a function of the ratio of electron beam current to space-charge limiting current. A new collective acceleration approach, in which cyclotron wave phase velocity is varied by modulation of electron beam voltage, is proposed. Acceleration by traveling Virtual Cathode or Localized Pinch was considered, but appears less promising. In support of this research, fundamental investigations of beam propagation in evacuated waveguides, of nonneutral beam linear eigenmodes, and of beam stability were carried out. Several computer programs were developed or enhanced. Plans for future work are discussed

  15. Cavity design programs

    International Nuclear Information System (INIS)

    Nelson, E.M.

    1996-01-01

    Numerous computer programs are available to help accelerator physicists and engineers model and design accelerator cavities and other microwave components. This article discusses the problems these programs solve and the principles upon which these programs are based. Some examples of how these programs are used in the design of accelerator cavities are also given

  16. Advanced Accelerator Applications University Participation Program

    Energy Technology Data Exchange (ETDEWEB)

    Y. Chen; A. Hechanova

    2007-07-25

    Our research tasks span the range of technology areas for transmutation, gas-cooled reactor technology, and high temperature heat exchangers, including separation of actinides from spent nuclear fuel, methods of fuel fabrication, reactor-accelerator coupled experiments, corrosion of materials exposed to lead-bismuth eutectic, and special nuclear materials protection and accountability.

  17. Cooperative wind turbine control for maximizing wind farm power using sequential convex programming

    International Nuclear Information System (INIS)

    Park, Jinkyoo; Law, Kincho H.

    2015-01-01

    Highlights: • The continuous wake model describes well the wake profile behind a wind turbine. • The wind farm power function describes well the power production of a wind farm. • Cooperative control increases the wind farm power efficiency by 7.3% in average. • SCP can be employed to efficiently optimize the control actions of wind turbines. - Abstract: This paper describes the use of a cooperative wind farm control approach to improve the power production of a wind farm. The power production by a downstream wind turbine can decrease significantly due to reduced wind speed caused by the upstream wind turbines, thereby lowering the overall wind farm power production efficiency. In spite of the interactions among the wind turbines, the conventional (greedy) wind turbine control strategy tries to maximize the power of each individual wind turbine by controlling its yaw angle, its blade pitch angle and its generator torque. To maximize the overall wind farm power production while taking the wake interference into account, this study employs a cooperative control strategy. We first derive the wind farm power as a differentiable function of the control actions for the wind turbines in a wind farm. The wind farm power function is then maximized using sequential convex programming (SCP) to determine the optimum coordinated control actions for the wind turbines. Using an example wind farm site and available wind data, we show how the cooperative control strategy improves the power production of the wind farm

  18. Plasma based accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, Allen [Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2015-05-01

    The concept of laser-induced plasma wakefields as a technique to accelerate charged particles was introduced 35 years ago as a means to go beyond the accelerating gradients possible with metallic cavities supporting radio frequency electromagnetic fields. Significant developments in laser technology have made possible the pulse intensity needed to realize this concept, and rapid progress is now underway in the realization of laser-driven plasma wakefield acceleration. It has also been realized that similar accelerating gradients can be produced by particle beams propagating in plasmas, and experimental programs have also been undertaken to study this possibility. Positive results have been achieved with electron-driven plasma wakefields, and a demonstration experiment with proton-driven wakefields is under construction at CERN. The concepts behind these different schemes and their pros and cons are described, as well as the experimental results achieved. An outlook for future practical uses of plasma based accelerators will also be given.

  19. CACTI: free, open-source software for the sequential coding of behavioral interactions.

    Science.gov (United States)

    Glynn, Lisa H; Hallgren, Kevin A; Houck, Jon M; Moyers, Theresa B

    2012-01-01

    The sequential analysis of client and clinician speech in psychotherapy sessions can help to identify and characterize potential mechanisms of treatment and behavior change. Previous studies required coding systems that were time-consuming, expensive, and error-prone. Existing software can be expensive and inflexible, and furthermore, no single package allows for pre-parsing, sequential coding, and assignment of global ratings. We developed a free, open-source, and adaptable program to meet these needs: The CASAA Application for Coding Treatment Interactions (CACTI). Without transcripts, CACTI facilitates the real-time sequential coding of behavioral interactions using WAV-format audio files. Most elements of the interface are user-modifiable through a simple XML file, and can be further adapted using Java through the terms of the GNU Public License. Coding with this software yields interrater reliabilities comparable to previous methods, but at greatly reduced time and expense. CACTI is a flexible research tool that can simplify psychotherapy process research, and has the potential to contribute to the improvement of treatment content and delivery.

  20. The Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.

    1992-01-01

    The Brookhaven National Laboratory Accelerator Test Facility comprises a 50 MeV traveling wave electron linear accelerator utilizing a high gradient, photo-excited, raidofrequency electron gun as an injector and an experimental area for study of new acceleration methods or advanced radiation sources using free electron lasers. Early operation of the linear accelerator system including calculated and measured beam parameters are presented together with the experimental program for accelerator physics and free electron laser studies

  1. IOTA (Integrable Optics Test Accelerator): facility and experimental beam physics program

    Science.gov (United States)

    Antipov, S.; Broemmelsiek, D.; Bruhwiler, D.; Edstrom, D.; Harms, E.; Lebedev, V.; Leibfritz, J.; Nagaitsev, S.; Park, C. S.; Piekarz, H.; Piot, P.; Prebys, E.; Romanov, A.; Ruan, J.; Sen, T.; Stancari, G.; Thangaraj, C.; Thurman-Keup, R.; Valishev, A.; Shiltsev, V.

    2017-03-01

    The Integrable Optics Test Accelerator (IOTA) is a storage ring for advanced beam physics research currently being built and commissioned at Fermilab. It will operate with protons and electrons using injectors with momenta of 70 and 150 MeV/c, respectively. The research program includes the study of nonlinear focusing integrable optical beam lattices based on special magnets and electron lenses, beam dynamics of space-charge effects and their compensation, optical stochastic cooling, and several other experiments. In this article, we present the design and main parameters of the facility, outline progress to date and provide the timeline of the construction, commissioning and research. The physical principles, design, and hardware implementation plans for the major IOTA experiments are also discussed.

  2. IOTA (Integrable Optics Test Accelerator): Facility and experimental beam physics program

    International Nuclear Information System (INIS)

    Antipov, Sergei; Broemmelsiek, Daniel; Bruhwiler, David; Edstrom, Dean; Harms, Elvin

    2017-01-01

    The Integrable Optics Test Accelerator (IOTA) is a storage ring for advanced beam physics research currently being built and commissioned at Fermilab. It will operate with protons and electrons using injectors with momenta of 70 and 150 MeV/c, respectively. The research program includes the study of nonlinear focusing integrable optical beam lattices based on special magnets and electron lenses, beam dynamics of space-charge effects and their compensation, optical stochastic cooling, and several other experiments. In this article, we present the design and main parameters of the facility, outline progress to date and provide the timeline of the construction, commissioning and research. Finally, the physical principles, design, and hardware implementation plans for the major IOTA experiments are also discussed.

  3. Sequential Generalized Transforms on Function Space

    Directory of Open Access Journals (Sweden)

    Jae Gil Choi

    2013-01-01

    Full Text Available We define two sequential transforms on a function space Ca,b[0,T] induced by generalized Brownian motion process. We then establish the existence of the sequential transforms for functionals in a Banach algebra of functionals on Ca,b[0,T]. We also establish that any one of these transforms acts like an inverse transform of the other transform. Finally, we give some remarks about certain relations between our sequential transforms and other well-known transforms on Ca,b[0,T].

  4. Innovating in Health Care Management Education: Development of an Accelerated MBA and MPH Degree Program at Yale

    Science.gov (United States)

    Forman, Howard P.; Pistell, Anne F.; Nembhard, Ingrid M.

    2015-01-01

    Increasingly, there is recognition of the need for individuals with expertise in both management and public health to help health care organizations deliver high-quality and cost-effective care. The Yale School of Public Health and Yale School of Management began offering an accelerated Master of Business Administration (MBA) and Master of Public Health (MPH) joint degree program in the summer of 2014. This new program enables students to earn MBA and MPH degrees simultaneously from 2 fully accredited schools in 22 months. Students will graduate with the knowledge and skills needed to become innovative leaders of health care organizations. We discuss the rationale for the program, the developmental process, the curriculum, benefits of the program, and potential challenges. PMID:25706023

  5. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis; Paaske, Erik

    1998-01-01

    We describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon (RS) codes with nonuniform profile. With this scheme decoding with good performance is possible as low...... as Eb/N0=0.6 dB, which is about 1.25 dB below the signal-to-noise ratio (SNR) that marks the cutoff rate for the full system. Accounting for about 0.45 dB due to the outer codes, sequential decoding takes place at about 1.7 dB below the SNR cutoff rate for the convolutional code. This is possible since...... the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability of computational overflow. Analytical results for the probability that the first RS word is decoded after C computations are presented. These results are supported...

  6. Simultaneous optimization of sequential IMRT plans

    International Nuclear Information System (INIS)

    Popple, Richard A.; Prellop, Perri B.; Spencer, Sharon A.; Santos, Jennifer F. de los; Duan, Jun; Fiveash, John B.; Brezovich, Ivan A.

    2005-01-01

    Radiotherapy often comprises two phases, in which irradiation of a volume at risk for microscopic disease is followed by a sequential dose escalation to a smaller volume either at a higher risk for microscopic disease or containing only gross disease. This technique is difficult to implement with intensity modulated radiotherapy, as the tolerance doses of critical structures must be respected over the sum of the two plans. Techniques that include an integrated boost have been proposed to address this problem. However, clinical experience with such techniques is limited, and many clinicians are uncomfortable prescribing nonconventional fractionation schemes. To solve this problem, we developed an optimization technique that simultaneously generates sequential initial and boost IMRT plans. We have developed an optimization tool that uses a commercial treatment planning system (TPS) and a high level programming language for technical computing. The tool uses the TPS to calculate the dose deposition coefficients (DDCs) for optimization. The DDCs were imported into external software and the treatment ports duplicated to create the boost plan. The initial, boost, and tolerance doses were specified and used to construct cost functions. The initial and boost plans were optimized simultaneously using a gradient search technique. Following optimization, the fluence maps were exported to the TPS for dose calculation. Seven patients treated using sequential techniques were selected from our clinical database. The initial and boost plans used to treat these patients were developed independently of each other by dividing the tolerance doses proportionally between the initial and boost plans and then iteratively optimizing the plans until a summation that met the treatment goals was obtained. We used the simultaneous optimization technique to generate plans that met the original planning goals. The coverage of the initial and boost target volumes in the simultaneously optimized

  7. Synthesis of sequential control algorithms for pneumatic drives controlled by monostable valves

    Directory of Open Access Journals (Sweden)

    Ł. Dworzak

    2009-07-01

    Full Text Available Application of the Grafpol method [1] for synthesising sequential control algorithms for pneumatic drives controlled by monostable valves is presented. The developed principles simplify the MTS method of programming production processes in the scope of the memory realisation [2]. Thanks to this, time for synthesising the schematic equation can be significantly reduced in comparison to the network transformation method [3]. The designed schematic equation makes a ground for writing an application program of a PLC using any language defined in IEC 61131-3.

  8. Sequential probability ratio controllers for safeguards radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.L.; Nixon, K.V.

    1984-01-01

    Sequential hypothesis tests applied to nuclear safeguards accounting methods make the methods more sensitive to detecting diversion. The sequential tests also improve transient signal detection in safeguards radiation monitors. This paper describes three microprocessor control units with sequential probability-ratio tests for detecting transient increases in radiation intensity. The control units are designed for three specific applications: low-intensity monitoring with Poisson probability ratios, higher intensity gamma-ray monitoring where fixed counting intervals are shortened by sequential testing, and monitoring moving traffic where the sequential technique responds to variable-duration signals. The fixed-interval controller shortens a customary 50-s monitoring time to an average of 18 s, making the monitoring delay less bothersome. The controller for monitoring moving vehicles benefits from the sequential technique by maintaining more than half its sensitivity when the normal passage speed doubles

  9. IFMIF accelerator conceptual design activities

    International Nuclear Information System (INIS)

    Jameson, R.A.; Lagniel, J.M.; Sugimoto, M.; Kein, H.; Piaszczyk, C.; Tiplyakov, V.

    1998-01-01

    A Conceptual Design Evaluation (CDE) for the International Fusion Materials Irradiation Facility (IFMIF) began in 1997 and will be completed in 1998, as an international program of the IEA involving the European Community, Japan, Russia and the United States. The IFMIF accelerator system, comprising two 125 mA, 40 MeV deuterium accelerators operating at 175 MHz, is a key element of the IFMIF facility. The objectives and accomplishments of the CDE accelerator studies are outlined

  10. Biased lineups: sequential presentation reduces the problem.

    Science.gov (United States)

    Lindsay, R C; Lea, J A; Nosworthy, G J; Fulford, J A; Hector, J; LeVan, V; Seabrook, C

    1991-12-01

    Biased lineups have been shown to increase significantly false, but not correct, identification rates (Lindsay, Wallbridge, & Drennan, 1987; Lindsay & Wells, 1980; Malpass & Devine, 1981). Lindsay and Wells (1985) found that sequential lineup presentation reduced false identification rates, presumably by reducing reliance on relative judgment processes. Five staged-crime experiments were conducted to examine the effect of lineup biases and sequential presentation on eyewitness recognition accuracy. Sequential lineup presentation significantly reduced false identification rates from fair lineups as well as from lineups biased with regard to foil similarity, instructions, or witness attire, and from lineups biased in all of these ways. The results support recommendations that police present lineups sequentially.

  11. Lineup composition, suspect position, and the sequential lineup advantage.

    Science.gov (United States)

    Carlson, Curt A; Gronlund, Scott D; Clark, Steven E

    2008-06-01

    N. M. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001) argued that sequential lineups reduce the likelihood of mistaken eyewitness identification. Experiment 1 replicated the design of R. C. L. Lindsay and G. L. Wells (1985), the first study to show the sequential lineup advantage. However, the innocent suspect was chosen at a lower rate in the simultaneous lineup, and no sequential lineup advantage was found. This led the authors to hypothesize that protection from a sequential lineup might emerge only when an innocent suspect stands out from the other lineup members. In Experiment 2, participants viewed a simultaneous or sequential lineup with either the guilty suspect or 1 of 3 innocent suspects. Lineup fairness was varied to influence the degree to which a suspect stood out. A sequential lineup advantage was found only for the unfair lineups. Additional analyses of suspect position in the sequential lineups showed an increase in the diagnosticity of suspect identifications as the suspect was placed later in the sequential lineup. These results suggest that the sequential lineup advantage is dependent on lineup composition and suspect position. (c) 2008 APA, all rights reserved

  12. Electron-beam direct drive for rf accelerator cavities

    International Nuclear Information System (INIS)

    Nahemow, M.D.; Humphries, S. Jr.

    1987-01-01

    This paper describes a Program to Demonstrate Electron-Beam Direct Drive for Radio Frequency (RF) Linear Accelerators at the Westinghouse R and D Center. The experimental program was undertaken using an existing electron beam facility at the Westinghouse R and C Center to demonstrate the potential of the Direct Drive RF Cavities for High Power Beams concept discussed as part of a program to develop a viable alternate concept for driving RF linear accelerators

  13. Beyond Grand Rounds: A Comprehensive and Sequential Intervention to Improve Identification of Delirium

    Science.gov (United States)

    Ramaswamy, Ravishankar; Dix, Edward F.; Drew, Janet E.; Diamond, James J.; Inouye, Sharon K.; Roehl, Barbara J. O.

    2011-01-01

    Purpose of the Study: Delirium is a widespread concern for hospitalized seniors, yet is often unrecognized. A comprehensive and sequential intervention (CSI) aiming to effect change in clinician behavior by improving knowledge about delirium was tested. Design and Methods: A 2-day CSI program that consisted of progressive 4-part didactic series,…

  14. Improved voltage performance of the Oak Ridge 25URC tandem accelerator

    International Nuclear Information System (INIS)

    Meigs, M.J.; Jones, C.M.; Haynes, D.L.; Juras, R.C.; Ziegler, N.F.; Raatz, J.E.; Rathmell, R.D.

    1988-01-01

    While voltage performance of the accelerator has been adequate for the experimental program to date, it seemed clear that improvement in voltage performance could be of direct benefit to the experimental program in the future. Therefore, we began, in June 1986, a program of modifications and tests which was designed to improve voltage performance of the accelerator. In this paper, we discuss the final phase of this program and initial tests of the accelerator following completion of this final phase. 11 refs., 4 figs

  15. Multichannel computerized control system of current pulses in LIU-30 electron accelerator

    CERN Document Server

    Gerasimov, A I; Kulgavchuk, V V; Pluzhnikov, A V

    2002-01-01

    In LIU-30 power linear pulsed induction electron accelerator (40 MeV, 10 kA, 25 ns) 288 radial lines with water insulation serve as energy accumulators and shapers of accelerating voltage pulses. The lines are charged simultaneously up to 500 kV using a system comprising 72 Arkadiev-Marx screened generators. To control parameter of synchronous pulses of charging current with up to 60 kA amplitude and 0.85 mu s duration in every of 72 charging circuits one applies a computer-aided system. Current pulse is recorded at output of every generator using the Rogowski coil signal from which via a cable line is transmitted to an analog-digital converter, is processed with 50 ns sampling and is recorded to a memory unit. Upon actuation of accelerator the signals are sequentially or selectively displayed and are compared with pulse typical shape

  16. Tradable permit allocations and sequential choice

    Energy Technology Data Exchange (ETDEWEB)

    MacKenzie, Ian A. [Centre for Economic Research, ETH Zuerich, Zurichbergstrasse 18, 8092 Zuerich (Switzerland)

    2011-01-15

    This paper investigates initial allocation choices in an international tradable pollution permit market. For two sovereign governments, we compare allocation choices that are either simultaneously or sequentially announced. We show sequential allocation announcements result in higher (lower) aggregate emissions when announcements are strategic substitutes (complements). Whether allocation announcements are strategic substitutes or complements depends on the relationship between the follower's damage function and governments' abatement costs. When the marginal damage function is relatively steep (flat), allocation announcements are strategic substitutes (complements). For quadratic abatement costs and damages, sequential announcements provide a higher level of aggregate emissions. (author)

  17. An Accelerator Control Middle Layer Using MATLAB

    International Nuclear Information System (INIS)

    Portmann, Gregory J.; Corbett, Jeff; Terebilo, Andrei

    2005-01-01

    Matlab is a matrix manipulation language originally developed to be a convenient language for using the LINPACK and EISPACK libraries. What makes Matlab so appealing for accelerator physics is the combination of a matrix oriented programming language, an active workspace for system variables, powerful graphics capability, built-in math libraries, and platform independence. A number of software toolboxes for accelerators have been written in Matlab--the Accelerator Toolbox (AT) for machine simulations, LOCO for accelerator calibration, Matlab Channel Access Toolbox (MCA) for EPICS connections, and the Middle Layer. This paper will describe the ''middle layer'' software toolbox that resides between the high-level control applications and the low-level accelerator control system. This software was a collaborative effort between ALS (LBNL) and SPEAR3 (SSRL) but easily ports to other machines. Five accelerators presently use this software. The high-level Middle Layer functionality includes energy ramp, configuration control (save/restore), global orbit correction, local photon beam steering, insertion device compensation, beam-based alignment, tune correction, response matrix measurement, and script-based programs for machine physics studies

  18. Community Petascale Project for Accelerator Science and Simulation: Advancing Computational Science for Future Accelerators and Accelerator Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Spentzouris, P.; /Fermilab; Cary, J.; /Tech-X, Boulder; McInnes, L.C.; /Argonne; Mori, W.; /UCLA; Ng, C.; /SLAC; Ng, E.; Ryne, R.; /LBL, Berkeley

    2011-11-14

    The design and performance optimization of particle accelerators are essential for the success of the DOE scientific program in the next decade. Particle accelerators are very complex systems whose accurate description involves a large number of degrees of freedom and requires the inclusion of many physics processes. Building on the success of the SciDAC-1 Accelerator Science and Technology project, the SciDAC-2 Community Petascale Project for Accelerator Science and Simulation (ComPASS) is developing a comprehensive set of interoperable components for beam dynamics, electromagnetics, electron cooling, and laser/plasma acceleration modelling. ComPASS is providing accelerator scientists the tools required to enable the necessary accelerator simulation paradigm shift from high-fidelity single physics process modeling (covered under SciDAC1) to high-fidelity multiphysics modeling. Our computational frameworks have been used to model the behavior of a large number of accelerators and accelerator R&D experiments, assisting both their design and performance optimization. As parallel computational applications, the ComPASS codes have been shown to make effective use of thousands of processors. ComPASS is in the first year of executing its plan to develop the next-generation HPC accelerator modeling tools. ComPASS aims to develop an integrated simulation environment that will utilize existing and new accelerator physics modules with petascale capabilities, by employing modern computing and solver technologies. The ComPASS vision is to deliver to accelerator scientists a virtual accelerator and virtual prototyping modeling environment, with the necessary multiphysics, multiscale capabilities. The plan for this development includes delivering accelerator modeling applications appropriate for each stage of the ComPASS software evolution. Such applications are already being used to address challenging problems in accelerator design and optimization. The ComPASS organization

  19. Accelerator development for heavy ion fusion

    International Nuclear Information System (INIS)

    Talbert, W.L. Jr.; Sawyer, G.A.

    1980-01-01

    Accelerator technology development is presented for heavy ion drivers used in inertial confinement fusion. The program includes construction of low-velocity ''test bed'' accelerator facilities, development of analytical and experimental techniques to characterize ion beam behavior, and the study of ion beam energy deposition

  20. Accelerated testing of space batteries

    Science.gov (United States)

    Mccallum, J.; Thomas, R. E.; Waite, J. H.

    1973-01-01

    An accelerated life test program for space batteries is presented that fully satisfies empirical, statistical, and physical criteria for validity. The program includes thermal and other nonmechanical stress analyses as well as mechanical stress, strain, and rate of strain measurements.

  1. Applying the minimax principle to sequential mastery testing

    NARCIS (Netherlands)

    Vos, Hendrik J.

    2002-01-01

    The purpose of this paper is to derive optimal rules for sequential mastery tests. In a sequential mastery test, the decision is to classify a subject as a master, a nonmaster, or to continue sampling and administering another random item. The framework of minimax sequential decision theory (minimum

  2. General purpose programmable accelerator board

    Science.gov (United States)

    Robertson, Perry J.; Witzke, Edward L.

    2001-01-01

    A general purpose accelerator board and acceleration method comprising use of: one or more programmable logic devices; a plurality of memory blocks; bus interface for communicating data between the memory blocks and devices external to the board; and dynamic programming capabilities for providing logic to the programmable logic device to be executed on data in the memory blocks.

  3. Classical and sequential limit analysis revisited

    Science.gov (United States)

    Leblond, Jean-Baptiste; Kondo, Djimédo; Morin, Léo; Remmal, Almahdi

    2018-04-01

    Classical limit analysis applies to ideal plastic materials, and within a linearized geometrical framework implying small displacements and strains. Sequential limit analysis was proposed as a heuristic extension to materials exhibiting strain hardening, and within a fully general geometrical framework involving large displacements and strains. The purpose of this paper is to study and clearly state the precise conditions permitting such an extension. This is done by comparing the evolution equations of the full elastic-plastic problem, the equations of classical limit analysis, and those of sequential limit analysis. The main conclusion is that, whereas classical limit analysis applies to materials exhibiting elasticity - in the absence of hardening and within a linearized geometrical framework -, sequential limit analysis, to be applicable, strictly prohibits the presence of elasticity - although it tolerates strain hardening and large displacements and strains. For a given mechanical situation, the relevance of sequential limit analysis therefore essentially depends upon the importance of the elastic-plastic coupling in the specific case considered.

  4. Systemic Analysis, Mapping, Modeling, and Simulation of the Advanced Accelerator Applications Program

    International Nuclear Information System (INIS)

    Guan, Yue; Laidler, James J.; Morman, James A.

    2002-01-01

    Advanced chemical separations methods envisioned for use in the Department of Energy Advanced Accelerator Applications (AAA) program have been studied using the Systemic Analysis, Mapping, Modeling, and Simulation (SAMMS) method. This integrated and systematic method considers all aspects of the studied process as one dynamic and inter-dependent system. This particular study focuses on two subjects: the chemical separation processes for treating spent nuclear fuel, and the associated non-proliferation implications of such processing. Two levels of chemical separation models are developed: level 1 models treat the chemical process stages by groups; and level 2 models depict the details of each process stage. Models to estimate the proliferation risks based on proliferation barrier assessment are also developed. This paper describes the research conducted for the single-stratum design in the AAA program. Further research conducted for the multi-strata designs will be presented later. The method and models described in this paper can help in the design of optimized processes that fulfill the chemical separation process specifications and non-proliferation requirements. (authors)

  5. Some problems in the technique of high-voltage testing of the accelerating tube gaps in electrostatic accelerators

    International Nuclear Information System (INIS)

    Romanov, V.A.; Ivanov, V.V.; Mukhametshin, V.I.; Dmitriev, E.P.; Kidalov, A.I.

    1983-01-01

    Problems arising during high-voltage testing and training of accelerating taubes of electrostatic accelrators are discussed. A rig and technique of the accelerating tube testing and program designed for the processing of the data obtained and sorting out of the samples investigated are described

  6. A quality assurance program for ancillary high technology devices on a dual-energy accelerator

    International Nuclear Information System (INIS)

    Klein, Eric E.; Low, Daniel A.; Maag, Derek; Purdy, James A.

    1996-01-01

    Our facility has added high-technology ancillary devices to our dual-energy linear accelerator. After commissioning and acceptance testing of dual asymmetric jaws, dynamic wedge, portal imaging, and multileaf collimation (MLC), quality assurance programs were instituted. The programs were designed to be both periodic and patient specific when required. In addition, when dosimetric aspects were affected by these technologies, additional quality assurance checks were added. Positional accuracy checks (light and radiation) are done for both asymmetric jaws and MLC. Each patient MLC field is checked against the original simulation or digitally reconstructed radiographs. Off-axis factors and output checks are performed for asymmetric fields. Dynamic wedge transmission factors and profiles are checked periodically, and a patient diode check is performed for every new dynamic wedge portal. On-line imaging checks encompass safety checks along with periodic measurement of contrast and spatial resolution. The most important quality assurance activity is the annual review of proper operation and procedures for each device. Our programs have been successful in avoiding patient-related errors or device malfunctions. The programs are a team effort involving physicists, maintenance engineers, and therapists

  7. User's guide of parallel program development environment (PPDE). The 2nd edition

    International Nuclear Information System (INIS)

    Ueno, Hirokazu; Takemiya, Hiroshi; Imamura, Toshiyuki; Koide, Hiroshi; Matsuda, Katsuyuki; Higuchi, Kenji; Hirayama, Toshio; Ohta, Hirofumi

    2000-03-01

    The STA basic system has been enhanced to accelerate support for parallel programming on heterogeneous parallel computers, through a series of R and D on the technology of parallel processing. The enhancement has been made through extending the function of the PPDF, Parallel Program Development Environment in the STA basic system. The extended PPDE has the function to make: 1) the automatic creation of a 'makefile' and a shell script file for its execution, 2) the multi-tools execution which makes the tools on heterogeneous computers to execute with one operation a task on a computer, and 3) the mirror composition to reflect editing results of a file on a computer into all related files on other computers. These additional functions will enhance the work efficiency for program development on some computers. More functions have been added to the PPDE to provide help for parallel program development. New functions were also designed to complement a HPF translator and a parallelizing support tool when working together so that a sequential program is efficiently converted to a parallel program. This report describes the use of extended PPDE. (author)

  8. User's guide of parallel program development environment (PPDE). The 2nd edition

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Hirokazu; Takemiya, Hiroshi; Imamura, Toshiyuki; Koide, Hiroshi; Matsuda, Katsuyuki; Higuchi, Kenji; Hirayama, Toshio [Center for Promotion of Computational Science and Engineering, Japan Atomic Energy Research Institute, Tokyo (Japan); Ohta, Hirofumi [Hitachi Ltd., Tokyo (Japan)

    2000-03-01

    The STA basic system has been enhanced to accelerate support for parallel programming on heterogeneous parallel computers, through a series of R and D on the technology of parallel processing. The enhancement has been made through extending the function of the PPDF, Parallel Program Development Environment in the STA basic system. The extended PPDE has the function to make: 1) the automatic creation of a 'makefile' and a shell script file for its execution, 2) the multi-tools execution which makes the tools on heterogeneous computers to execute with one operation a task on a computer, and 3) the mirror composition to reflect editing results of a file on a computer into all related files on other computers. These additional functions will enhance the work efficiency for program development on some computers. More functions have been added to the PPDE to provide help for parallel program development. New functions were also designed to complement a HPF translator and a paralleilizing support tool when working together so that a sequential program is efficiently converted to a parallel program. This report describes the use of extended PPDE. (author)

  9. Search for Dark Photons with Accelerators

    Directory of Open Access Journals (Sweden)

    Merkel Harald

    2014-01-01

    Full Text Available A dark photon as the mediator of an interaction of the dark sector is a well motivated extension of the standard model. While possible dark matter particles are heavy and seem to be beyond the reach of current accelerators, the dark photon is not necessarily heavy and might have a mass in the range of existing accelerators. In recent years, an extensive experimental program at several accelerators for the search for dark photons were established. In this talk, recent results and progress in the determination of exclusion limits with accelerators is presented.

  10. Lepton accelerators and radiation sources: R and D investment at BNL

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Fernow, R.; Gallardo, J.; Hart, M.; Hastings, J.; Johnson, E.; Krinsky, S.; Palmer, R.; Yu, L.H.

    1997-03-01

    Brookhaven National Laboratory (BNL) has shown its determination to remain at the forefront of accelerator based science through its continued investment in long range accelerator R and D. The laboratory has a broad program in accelerator technology development including projects such as high T c magnets at RHIC, Siberian Snakes at the AGS, brightness upgrades on the NSLS storage ring, and spallation source R and D in several departments. This report focuses on a segment of the overall program: the lepton accelerator and coherent radiation source R and D at the laboratory. These efforts are aimed at (1) development of high brightness electron beams, (2) novel acceleration techniques, (3) seeded Free Electron Laser (FEL) development, and (4) R and D for a muon collider. To pursue these objectives, BNL ha over the past decade introduced new organizational arrangements. The BNL Center for Accelerator Physics (CAP) is an interdepartmental unit dedicated to promoting R and D which, cannot be readily conducted within the programs of operating facilities. The Accelerator Test Facility (ATF) is managed by CAP and NSLS as a user facility dedicated to accelerator and beam physics problems of interest to both the High Energy Physics and Basic Energy Sciences programs of the DOE. Capitalizing on these efforts, the Source Development Laboratory (SDL) was established by the NSLS to facilitate coordinated development of sources and experiments to produce and utilize coherent sub-picosecond synchrotron radiation. This White Paper describes the programs being pursued at CAP, ATF and SDL aimed at advancing basic knowledge of lepton accelerators and picosecond radiation sources

  11. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    Science.gov (United States)

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  12. SLAC accelerator operations report: 1995--1997

    International Nuclear Information System (INIS)

    Erickson, R.; Allen, C.W.; Anderson, S.; Linebarger, W.; Stanek, M.

    1997-05-01

    Operational statistics for the linear accelerator programs at SLAC are presented, including run-time records for SLC and the fixed-target programs. Also included are summaries of reliability and maintenance-related statistics

  13. Design of the detuned accelerator structure

    International Nuclear Information System (INIS)

    Wang, J.W.; Nelson, E.M.

    1993-05-01

    This is a summary of the design procedure for the detuned accelerator structure for SLAC's Next Linear Collider (NLC) program. The 11.424 GHz accelerating mode of each cavity must be synchronous with the beam. The distribution of the disk thicknesses and lowest synchronous dipole mode frequencies of the cavities in the structure is Gaussian in order to reduce the effect of wake fields. The finite element field solver YAP calculated the accelerating mode frequency and the lowest synchronous dipole mode frequency for various cavity diameters, aperture diameters and disk thicknesses. Polynomial 3-parameter fits are used to calculate the dimensions for a 1.8 m detuned structure. The program SUPERFISH was used to calculate the shunt impedances, quality factors and group velocities. The RF parameters of the section like filling time, attenuation factor, accelerating gradient and maximum surface field along the section are evaluated. Error estimates will be discussed and comparisons with conventional constant gradient and constant impedance structures will be presented

  14. Accelerator research studies

    International Nuclear Information System (INIS)

    1990-01-01

    This progress report for the Accelerator Research Studies program at the University of Maryland covers the second year (June 1, 1989 to May 31, 1990) of the current three-year contract period from June 1, 1988 to May 31, 1991, funded by the Department of Energy under Contract No. AC05-85ER40216. The research program is divided into three separate tasks, as follows: the study of Transport and Longitudinal Compression of Intense, High-Brightness Beams; the study of Collective Ion Acceleration by Intense Electron Beams and Pulse-Powered Plasma Focus; the study of Microwave Sources and Parameter Scaling for High-Frequency Linacs. This report consists of three sections in which the progress for each task is documented separately. An introduction and synopsis is presented at the beginning of the progress report for each task

  15. Trial Sequential Methods for Meta-Analysis

    Science.gov (United States)

    Kulinskaya, Elena; Wood, John

    2014-01-01

    Statistical methods for sequential meta-analysis have applications also for the design of new trials. Existing methods are based on group sequential methods developed for single trials and start with the calculation of a required information size. This works satisfactorily within the framework of fixed effects meta-analysis, but conceptual…

  16. Mass acceleration in a multi-module plasma jet for impact fusion. Final report, 21 May 1984-21 May 1985

    International Nuclear Information System (INIS)

    Burton, R.L.; Goldstein, S.A.; Tidman, D.A.; Massey, D.W.; Winsor, N.K.; Witherspoon, F.D.

    1985-07-01

    GT-Devices began work on multi-module mass accelerators for impact fusion in 1981. The technique employs sequentially switched high pressure plasma jets to accelerate a lightweight projectile in a circular barrel. The purpose of the work of the past 12 months was to improve the understanding of the plasma jet acceleration process, and to translate that understanding into verifiable results. Both goals have been accomplished. During the past year we conceived, designed, built and fired 325 shots on the Module Test Facility (MTF). This facility provided sufficient diagnostics to investigate a wide variety of geometries, plasmas and current pulses, so that rapid progress was made

  17. Comparing cluster-level dynamic treatment regimens using sequential, multiple assignment, randomized trials: Regression estimation and sample size considerations.

    Science.gov (United States)

    NeCamp, Timothy; Kilbourne, Amy; Almirall, Daniel

    2017-08-01

    Cluster-level dynamic treatment regimens can be used to guide sequential treatment decision-making at the cluster level in order to improve outcomes at the individual or patient-level. In a cluster-level dynamic treatment regimen, the treatment is potentially adapted and re-adapted over time based on changes in the cluster that could be impacted by prior intervention, including aggregate measures of the individuals or patients that compose it. Cluster-randomized sequential multiple assignment randomized trials can be used to answer multiple open questions preventing scientists from developing high-quality cluster-level dynamic treatment regimens. In a cluster-randomized sequential multiple assignment randomized trial, sequential randomizations occur at the cluster level and outcomes are observed at the individual level. This manuscript makes two contributions to the design and analysis of cluster-randomized sequential multiple assignment randomized trials. First, a weighted least squares regression approach is proposed for comparing the mean of a patient-level outcome between the cluster-level dynamic treatment regimens embedded in a sequential multiple assignment randomized trial. The regression approach facilitates the use of baseline covariates which is often critical in the analysis of cluster-level trials. Second, sample size calculators are derived for two common cluster-randomized sequential multiple assignment randomized trial designs for use when the primary aim is a between-dynamic treatment regimen comparison of the mean of a continuous patient-level outcome. The methods are motivated by the Adaptive Implementation of Effective Programs Trial which is, to our knowledge, the first-ever cluster-randomized sequential multiple assignment randomized trial in psychiatry.

  18. Theoretical and Experimental Studies in Accelerator Physics

    Energy Technology Data Exchange (ETDEWEB)

    Rosenzweig, James [Univ. of California, Los Angeles, CA (United States). Dept. of Physics and Astronomy

    2017-03-08

    This report describes research supported by the US Dept. of Energy Office of High Energy Physics (OHEP), performed by the UCLA Particle Beam Physics Laboratory (PBPL). The UCLA PBPL has, over the last two decades-plus, played a critical role in the development of advanced accelerators, fundamental beam physics, and new applications enabled by these thrusts, such as new types of accelerator-based light sources. As the PBPL mission is broad it is natural that it has been grown within the context of the accelerator science and technology stewardship of the OHEP. Indeed, steady OHEP support for the program has always been central to the success of the PBPL; it has provided stability, and above all has set the over-arching themes for our research directions, which have producing over 500 publications (>120 in high level journals). While other agency support has grown notably in recent years, permitting more vigorous pursuit of the program, it is transient by comparison. Beyond permitting program growth in a time of flat OHEP budgets, the influence of other agency missions is found in push to adapt advanced accelerator methods to applications, in light of the success the field has had in proof-of-principle experiments supported first by the DoE OHEP. This three-pronged PBPL program — advanced accelerators, fundamental beam physics and technology, and revolutionary applications — has produced a generation of students that have had a profound affect on the US accelerator physics community. PBPL graduates, numbering 28 in total, form a significant population group in the accelerator community, playing key roles as university faculty, scientific leaders in national labs (two have been named Panofsky Fellows at SLAC), and vigorous proponents of industrial application of accelerators. Indeed, the development of advanced RF, optical and magnet technology at the PBPL has led directly to the spin-off company, RadiaBeam Technologies, now a leading industrial accelerator firm

  19. Accelerating and focusing structures for PIGMI

    International Nuclear Information System (INIS)

    Swenson, D.A.; Bush, E.D. Jr.; Holsinger, R.F.; Manca, J.J.; Saito, N.; Stovall, J.E.

    1977-01-01

    The National Cancer Institute is supporting a program of accelerator development at the Los Alamos Scientific Laboratory aimed at the extension of proton linac technologies to produce the most suitable Pion Generator for Medical Irradiations (PIGMI). An optimized design of a pion generator suitable for a radiotherapy program at a major medical center has been established, consisting of a 250-keV injector, followed by a 35-meter-long drift-tube linac that accelerates the proton beam to 150 MeV, and an 85-meter-long coupled-cavity linac that accelerates the beam to its final energy of 650 MeV, where the average beam current of 100 microamperes impinges on one or more targets producing abundant quantities of π - mesons for radiotherapeutic applications. A number of extensions to proton linac technology are being pursued under the PIGMI program at LASL. A discussion is given of recent developments in three areas relevant to the acceleration and focusing of proton beams, namely, the alternating phase focused (APF) linac structure, the disk and washer linac structure, and small permanent magnet quadrupole lenses. The APF linac structure is being developed for the acceleration and focusing role from the injection energy of 250 keV to a few MeV, where a transition is made to a permanent magnet quadrupole focused linac structure. The disk and washer linac structure is under consideration for the high velocity portion of the design

  20. A model for the design and programming of multi-cores

    NARCIS (Netherlands)

    Jesshope, C.; Grandinetti, L.

    2008-01-01

    This paper describes a machine/programming model for the era of multi-core chips. It is derived from the sequential model but replaces sequential composition with concurrent composition at all levels in the program except at the level where the compiler is able to make deterministic decisions on

  1. Accelerator Technology Division progress report, FY 1993

    International Nuclear Information System (INIS)

    Schriber, S.O.; Hardekopf, R.A.; Heighway, E.A.

    1993-01-01

    This report discusses the following topics: A Next-Generation Spallation-Neutron Source; Accelerator Performance Demonstration Facility; APEX Free-Electron Laser Project; The Ground Test Accelerator (GTA) Program; Intense Neutron Source for Materials Testing; Linac Physics and Special Projects; Magnetic Optics and Beam Diagnostics; Radio-Frequency Technology; Accelerator Controls and Automation; Very High-Power Microwave Sources and Effects; and GTA Installation, Commissioning, and Operation

  2. A working-set framework for sequential convex approximation methods

    DEFF Research Database (Denmark)

    Stolpe, Mathias

    2008-01-01

    We present an active-set algorithmic framework intended as an extension to existing implementations of sequential convex approximation methods for solving nonlinear inequality constrained programs. The framework is independent of the choice of approximations and the stabilization technique used...... to guarantee global convergence of the method. The algorithm works directly on the nonlinear constraints in the convex sub-problems and solves a sequence of relaxations of the current sub-problem. The algorithm terminates with the optimal solution to the sub-problem after solving a finite number of relaxations....

  3. Sequential light programs shape kale (Brassica napus) sprout appearance and alter metabolic and nutrient content

    Science.gov (United States)

    Carvalho, Sofia D; Folta, Kevin M

    2014-01-01

    Different light wavelengths have specific effects on plant growth and development. Narrow-bandwidth light-emitting diode (LED) lighting may be used to directionally manipulate size, color and metabolites in high-value fruits and vegetables. In this report, Red Russian kale (Brassica napus) seedlings were grown under specific light conditions and analyzed for photomorphogenic responses, pigment accumulation and nutraceutical content. The results showed that this genotype responds predictably to darkness, blue and red light, with suppression of hypocotyl elongation, development of pigments and changes in specific metabolites. However, these seedlings were relatively hypersensitive to far-red light, leading to uncharacteristically short hypocotyls and high pigment accumulation, even after growth under very low fluence rates (<1 μmol m−2 s−1). General antioxidant levels and aliphatic glucosinolates are elevated by far-red light treatments. Sequential treatments of darkness, blue light, red light and far-red light were applied throughout sprout development to alter final product quality. These results indicate that sequential treatment with narrow-bandwidth light may be used to affect key economically important traits in high-value crops. PMID:26504531

  4. Muon Sources for Particle Physics - Accomplishments of the Muon Accelerator Program

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Stratakis, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Palmer, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Delahaye, J.-P. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Summers, D. [Univ. of Mississippi, Oxford, MS (United States); Ryne, R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cummings, M. A. [Muons, Inc., Batavia, IL(United States)

    2017-05-01

    The Muon Accelerator Program (MAP) completed a four-year study on the feasibility of muon colliders and on using stored muon beams for neutrinos. That study was broadly successful in its goals, establishing the feasibility of lepton colliders from the 125 GeV Higgs Factory to more than 10 TeV, as well as exploring using a μ storage ring (MSR) for neutrinos, and establishing that MSRs could provide factory-level intensities of νe (ν$\\bar{e}$) and ν$\\bar{μ}$) (νμ) beams. The key components of the collider and neutrino factory systems were identified. Feasible designs and detailed simulations of all of these components were obtained, including some initial hardware component tests, setting the stage for future implementation where resources are available and clearly associated physics goals become apparent

  5. Centrifuge Study of Pilot Tolerance to Acceleration and the Effects of Acceleration on Pilot Performance

    Science.gov (United States)

    Creer, Brent Y.; Smedal, Harald A.; Wingrove, Rodney C.

    1960-01-01

    A research program the general objective of which was to measure the effects of various sustained accelerations on the control performance of pilots, was carried out on the Aviation Medical Acceleration Laboratory centrifuge, U.S. Naval Air Development Center, Johnsville, PA. The experimental setup consisted of a flight simulator with the centrifuge in the control loop. The pilot performed his control tasks while being subjected to acceleration fields such as might be encountered by a forward-facing pilot flying an atmosphere entry vehicle. The study was divided into three phases. In one phase of the program, the pilots were subjected to a variety of sustained linear acceleration forces while controlling vehicles with several different sets of longitudinal dynamics. Here, a randomly moving target was displayed to the pilot on a cathode-ray tube. For each combination of acceleration field and vehicle dynamics, pilot tracking accuracy was measured and pilot opinion of the stability and control characteristics was recorded. Thus, information was obtained on the combined effects of complexity of control task and magnitude and direction of acceleration forces on pilot performance. These tests showed that the pilot's tracking performance deteriorated markedly at accelerations greater than about 4g when controlling a lightly damped vehicle. The tentative conclusion was also reached that regardless of the airframe dynamics involved, the pilot feels that in order to have the same level of control over the vehicle, an increase in the vehicle dynamic stability was required with increases in the magnitudes of the acceleration impressed upon the pilot. In another phase, boundaries of human tolerance of acceleration were established for acceleration fields such as might be encountered by a pilot flying an orbital vehicle. A special pilot restraint system was developed to increase human tolerance to longitudinal decelerations. The results of the tests showed that human tolerance

  6. Physics design of an accelerator for an accelerator-driven subcritical system

    Directory of Open Access Journals (Sweden)

    Zhihui Li

    2013-08-01

    Full Text Available An accelerator-driven subcritical system (ADS program was launched in China in 2011, which aims to design and build an ADS demonstration facility with the capability of more than 1000 MW thermal power in multiple phases lasting about 20 years. The driver linac is defined to be 1.5 GeV in energy, 10 mA in current and in cw operation mode. To meet the extremely high reliability and availability, the linac is designed with much installed margin and fault tolerance, including hot-spare injectors and local compensation method for key element failures. The accelerator complex consists of two parallel 10-MeV injectors, a joint medium-energy beam transport line, a main linac, and a high-energy beam transport line. The superconducting acceleration structures are employed except for the radio frequency quadrupole accelerators (RFQs which are at room temperature. The general design considerations and the beam dynamics design of the driver linac complex are presented here.

  7. PAC++: Object-oriented platform for accelerator codes

    International Nuclear Information System (INIS)

    Malitsky, N.; Reshetov, A.; Bourianoff, G.

    1994-06-01

    Software packages in accelerator physics have relatively long life cycles. They had been developed and used for a wide range of accelerators in the past as well as for the current projects. For example, the basic algorithms written in the first accelerator Program TRANSPORT are actual for design of most magnet systems. Most of these packages had been implemented on Fortran. But this language is rather inconvenient as a basic language for large integrated projects that possibly could include real-time data acquisition, data base access, graphic riser interface modules (GUI), arid other features. Some later accelerator programs had been based on object-oriented tools (primarily, C++ language). These range from systems for advanced theoretical studies to control system software. For the new generations of accelerators it would be desirable to have an integrated platform in which all simulation and control tasks will be considered with one point of view. In this report the basic principles of an object-oriented platform for accelerator research software (PAC++) are suggested and analyzed. Primary objectives of this work are to enable efficient self-explaining realization of the accelerator concepts and to provide an integrated environment for the updating and the developing of the code

  8. Computer codes for beam dynamics analysis of cyclotronlike accelerators

    Science.gov (United States)

    Smirnov, V.

    2017-12-01

    Computer codes suitable for the study of beam dynamics in cyclotronlike (classical and isochronous cyclotrons, synchrocyclotrons, and fixed field alternating gradient) accelerators are reviewed. Computer modeling of cyclotron segments, such as the central zone, acceleration region, and extraction system is considered. The author does not claim to give a full and detailed description of the methods and algorithms used in the codes. Special attention is paid to the codes already proven and confirmed at the existing accelerating facilities. The description of the programs prepared in the worldwide known accelerator centers is provided. The basic features of the programs available to users and limitations of their applicability are described.

  9. Accelerated Leach Test(s) Program: Annual report

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Pietrzak, R.F.; Fuhrmann, M.; Colombo, P.

    1986-09-01

    A computerized data base of LLW leaching data has been developed. Long-term tests on portland cement, bitumen and vinyl ester-styrene (VES) polymer waste forms containing simulated wastes are underway which are designed to identify and evaluate factors that accelerate leaching without changing the mechanisms

  10. Sequential Optimization of Paths in Directed Graphs Relative to Different Cost Functions

    KAUST Repository

    Abubeker, Jewahir Ali

    2011-05-14

    This paper is devoted to the consideration of an algorithm for sequential optimization of paths in directed graphs relative to di_erent cost functions. The considered algorithm is based on an extension of dynamic programming which allows to represent the initial set of paths and the set of optimal paths after each application of optimization procedure in the form of a directed acyclic graph.

  11. An Efficient System Based On Closed Sequential Patterns for Web Recommendations

    OpenAIRE

    Utpala Niranjan; R.B.V. Subramanyam; V-Khana

    2010-01-01

    Sequential pattern mining, since its introduction has received considerable attention among the researchers with broad applications. The sequential pattern algorithms generally face problems when mining long sequential patterns or while using very low support threshold. One possible solution of such problems is by mining the closed sequential patterns, which is a condensed representation of sequential patterns. Recently, several researchers have utilized the sequential pattern discovery for d...

  12. AESS: Accelerated Exact Stochastic Simulation

    Science.gov (United States)

    Jenkins, David D.; Peterson, Gregory D.

    2011-12-01

    The Stochastic Simulation Algorithm (SSA) developed by Gillespie provides a powerful mechanism for exploring the behavior of chemical systems with small species populations or with important noise contributions. Gene circuit simulations for systems biology commonly employ the SSA method, as do ecological applications. This algorithm tends to be computationally expensive, so researchers seek an efficient implementation of SSA. In this program package, the Accelerated Exact Stochastic Simulation Algorithm (AESS) contains optimized implementations of Gillespie's SSA that improve the performance of individual simulation runs or ensembles of simulations used for sweeping parameters or to provide statistically significant results. Program summaryProgram title: AESS Catalogue identifier: AEJW_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEJW_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: University of Tennessee copyright agreement No. of lines in distributed program, including test data, etc.: 10 861 No. of bytes in distributed program, including test data, etc.: 394 631 Distribution format: tar.gz Programming language: C for processors, CUDA for NVIDIA GPUs Computer: Developed and tested on various x86 computers and NVIDIA C1060 Tesla and GTX 480 Fermi GPUs. The system targets x86 workstations, optionally with multicore processors or NVIDIA GPUs as accelerators. Operating system: Tested under Ubuntu Linux OS and CentOS 5.5 Linux OS Classification: 3, 16.12 Nature of problem: Simulation of chemical systems, particularly with low species populations, can be accurately performed using Gillespie's method of stochastic simulation. Numerous variations on the original stochastic simulation algorithm have been developed, including approaches that produce results with statistics that exactly match the chemical master equation (CME) as well as other approaches that approximate the CME. Solution

  13. Accelerator research studies

    International Nuclear Information System (INIS)

    1993-01-01

    The Accelerator Research Studies program at the University of Maryland, sponsored by the Department of Energy under grant number DE-FG05-91ER40642, is currently in the second year of a three-year funding cycle. The program consists of the following three tasks: TASK A, ''Study of Transport and Longitudinal Compression of Intense, High-Brightness Beams,'' (P.I., M. Reiser); TASK B, ''Study of Collective Ion Acceleration by Intense Electron Beams and Pseudospark Produced High Brightness Electron Beams,'' (Co-P.I.'s, W.W. Destler, M. Reiser, M.J. Rhee, and C.D. Striffler); TASK C, ''Study of a Gyroklystron High-Power Microwave Source for Linear Colliders,'' (Co-P.I.'s, V.L. Granatstein, W. Lawson, M. Reiser, and C.D. Striffler). In this report we document the progress that has been made during the past year for each of the three tasks

  14. The Maximum Cross-Correlation approach to detecting translational motions from sequential remote-sensing images

    Science.gov (United States)

    Gao, J.; Lythe, M. B.

    1996-06-01

    This paper presents the principle of the Maximum Cross-Correlation (MCC) approach in detecting translational motions within dynamic fields from time-sequential remotely sensed images. A C program implementing the approach is presented and illustrated in a flowchart. The program is tested with a pair of sea-surface temperature images derived from Advanced Very High Resolution Radiometer (AVHRR) images near East Cape, New Zealand. Results show that the mean currents in the region have been detected satisfactorily with the approach.

  15. High-brightness H/sup -/ accelerators

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1987-01-01

    Neutral particle beam (NPB) devices based on high-brightness H/sup -/ accelerators are an important component of proposed strategic defense systems. The basic rational and R and D program are outlined and examples given of the underlying technology thrusts toward advanced systems. Much of the research accomplished in the past year is applicable to accelerator systems in general; some of these activities are discussed

  16. An Adiabatic Phase-Matching Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lemery, Francois [DESY; Floettmann, Klaus [DESY; Piot, Philippe [Northern Illinois U.; Kaertner, Franz X. [Hamburg U.; Assmann, Ralph [DESY

    2017-12-22

    We present a general concept to accelerate non-relativistic charged particles. Our concept employs an adiabatically-tapered dielectric-lined waveguide which supports accelerating phase velocities for synchronous acceleration. We propose an ansatz for the transient field equations, show it satisfies Maxwell's equations under an adiabatic approximation and find excellent agreement with a finite-difference time-domain computer simulation. The fields were implemented into the particle-tracking program {\\sc astra} and we present beam dynamics results for an accelerating field with a 1-mm-wavelength and peak electric field of 100~MV/m. The numerical simulations indicate that a $\\sim 200$-keV electron beam can be accelerated to an energy of $\\sim10$~MeV over $\\sim 10$~cm. The novel scheme is also found to form electron beams with parameters of interest to a wide range of applications including, e.g., future advanced accelerators, and ultra-fast electron diffraction.

  17. High-gradient compact linear accelerator

    Science.gov (United States)

    Carder, Bruce M.

    1998-01-01

    A high-gradient linear accelerator comprises a solid-state stack in a vacuum of five sets of disc-shaped Blumlein modules each having a center hole through which particles are sequentially accelerated. Each Blumlein module is a sandwich of two outer conductive plates that bracket an inner conductive plate positioned between two dielectric plates with different thicknesses and dielectric constants. A third dielectric core in the shape of a hollow cylinder forms a casing down the series of center holes, and it has a dielectric constant different that the two dielectric plates that sandwich the inner conductive plate. In operation, all the inner conductive plates are charged to the same DC potential relative to the outer conductive plates. Next, all the inner conductive plates are simultaneously shorted to the outer conductive plates at the outer diameters. The signal short will propagate to the inner diameters at two different rates in each Blumlein module. A faster wave propagates quicker to the third dielectric core across the dielectric plates with the closer spacing and lower dielectric constant. When the faster wave reaches the inner extents of the outer and inner conductive plates, it reflects back outward and reverses the field in that segment of the dielectric core. All the field segments in the dielectric core are then in unipolar agreement until the slower wave finally propagates to the third dielectric core across the dielectric plates with the wider spacing and higher dielectric constant. During such unipolar agreement, particles in the core are accelerated with gradients that exceed twenty megavolts per meter.

  18. Space experiments with particle accelerators: SEPAC

    International Nuclear Information System (INIS)

    Obayashi, T.

    1978-01-01

    In this paper, the program of the space experiments with particle accelerators (SEPAC) is described. The SEPAC is to be prepared for the Space Shuttle/First Spacelab Mission. It is planned in the SEPAC to carry out the active and interactive experiments on and in the Earth's ionosphere and magnetosphere. It is also intended to make an initial performance test for the overall program of Spacelab/SEPAC experiments. The instruments to be used are electron beam accelerators, MPD arcjects, and associated diagnostic equipments. The main scientific objectives of the experiments are Vehicle Charge Neutralization, Beam Plasma Physics, and Beam Atmosphere Interactions. The SEPAC system consists of the following subsystems. Those are accelerators, monitoring and diagnostic equipments, and control and data management equipments. The SEPAC functional objectives for experiment operations are SEPAC system checkout, EBA firing test, MPD firing test, electron beam experiments, plasma beam propagation, artificial aurora excitation, equatorial aerochemistry, electron echo experiment, E parallel B experiment, passive experiments, SEPAC system deactivation, and battery charging. Most experiment procedures are carried out by the pre-set computer program. (Kato, T.)

  19. Medical uses of accelerators

    International Nuclear Information System (INIS)

    Bradbury, J.N.

    1981-01-01

    A variety of particle accelerators have either potential or already demonstrated uses in connection with medically-related research, diagnosis, and treatment. For cancer radiotherapy, nuclear particles including protons, neutrons, heavy ions, and negative pi mesons have advantages compared to conventional radiations in terms of dose localization and/or biological effectiveness. Clinical evaluations of these particles are underway at a number of institutions. Accelerator-produced radionuclides are in widespread use for research and routine diagnostic purposes. Elemental analysis techniques with charged particles and neutrons are being applied to bone, blood, and other tissues. Finally, low-dose medical imaging can be accomplished with accelerated protons and heavy ions. The status and future of these programs are discussed

  20. Topics in radiation at accelerators: Radiation physics for personnel and environmental protection

    International Nuclear Information System (INIS)

    Cossairt, J.D.

    1993-11-01

    This report discusses the following topics: Composition of Accelerator Radiation Fields; Shielding of Electrons and Photons at Accelerators; Shielding of Hadrons at Accelerators; Low Energy Prompt Radiation Phenomena; Induced Radioactivity at Accelerators; Topics in Radiation Protection Instrumentation at Accelerators; and Accelerator Radiation Protection Program Elements

  1. Discrimination between sequential and simultaneous virtual channels with electrical hearing.

    Science.gov (United States)

    Landsberger, David; Galvin, John J

    2011-09-01

    In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects' discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation. © 2011 Acoustical Society of America

  2. Sequential avulsions of the tibial tubercle in an adolescent basketball player.

    Science.gov (United States)

    Huang, Ying Chieh; Chao, Ying-Hao; Lien, Fang-Chieh

    2010-05-01

    Tibial tubercle avulsion is an uncommon fracture in physically active adolescents. Sequential avulsion of tibial tubercles is extremely rare. We reported a healthy, active 15-year-old boy who suffered from left tibial tubercle avulsion fracture during a basketball game. He received open reduction and internal fixation with two smooth Kirschner wires and a cannulated screw, with every effort to reduce the plate injury. Long-leg splint was used for protection followed by programmed rehabilitation. He recovered uneventfully and returned to his previous level of activity soon. Another avulsion fracture happened at the right tibial tubercle 3.5 months later when he was playing the basketball. From the encouragement of previous successful treatment, we provided him open reduction and fixation with two small-caliber screws. He recovered uneventfully and returned to his previous level of activity soon. No genu recurvatum or other deformity was happening in our case at the end of 2-year follow-up. No evidence of Osgood-Schlatter disease or osteogenesis imperfecta was found. Sequential avulsion fractures of tibial tubercles are rare. Good functional recovery can often be obtained like our case if we treat it well. To a physically active adolescent, we should never overstate the risk of sequential avulsion of the other leg to postpone the return to an active, functional life.

  3. Sequential versus simultaneous market delineation

    DEFF Research Database (Denmark)

    Haldrup, Niels; Møllgaard, Peter; Kastberg Nielsen, Claus

    2005-01-01

    and geographical markets. Using a unique data setfor prices of Norwegian and Scottish salmon, we propose a methodologyfor simultaneous market delineation and we demonstrate that comparedto a sequential approach conclusions will be reversed.JEL: C3, K21, L41, Q22Keywords: Relevant market, econometric delineation......Delineation of the relevant market forms a pivotal part of most antitrustcases. The standard approach is sequential. First the product marketis delineated, then the geographical market is defined. Demand andsupply substitution in both the product dimension and the geographicaldimension...

  4. User's guide of parallel program development environment (PPDE). The 2nd edition

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Hirokazu; Takemiya, Hiroshi; Imamura, Toshiyuki; Koide, Hiroshi; Matsuda, Katsuyuki; Higuchi, Kenji; Hirayama, Toshio [Center for Promotion of Computational Science and Engineering, Japan Atomic Energy Research Institute, Tokyo (Japan); Ohta, Hirofumi [Hitachi Ltd., Tokyo (Japan)

    2000-03-01

    The STA basic system has been enhanced to accelerate support for parallel programming on heterogeneous parallel computers, through a series of R and D on the technology of parallel processing. The enhancement has been made through extending the function of the PPDF, Parallel Program Development Environment in the STA basic system. The extended PPDE has the function to make: 1) the automatic creation of a 'makefile' and a shell script file for its execution, 2) the multi-tools execution which makes the tools on heterogeneous computers to execute with one operation a task on a computer, and 3) the mirror composition to reflect editing results of a file on a computer into all related files on other computers. These additional functions will enhance the work efficiency for program development on some computers. More functions have been added to the PPDE to provide help for parallel program development. New functions were also designed to complement a HPF translator and a paralleilizing support tool when working together so that a sequential program is efficiently converted to a parallel program. This report describes the use of extended PPDE. (author)

  5. The United States Particle Accelerator School: Educating the Next Generation of Accelerator Scientists and Engineers

    International Nuclear Information System (INIS)

    Barletta, William A.

    2009-01-01

    Only a handful of universities in the US offer any formal training in accelerator science. The United States Particle Accelerator School (USPAS) is National Graduate Educational Program that has developed a highly successful educational paradigm that, over the past twenty-years, has granted more university credit in accelerator/beam science and technology than any university in the world. Sessions are held twice annually, hosted by major US research universities that approve course credit, certify the USPAS faculty, and grant course credit. The USPAS paradigm is readily extensible to other rapidly developing, cross-disciplinary research areas such as high energy density physics.

  6. The United States Particle Accelerator School: Educating the next generation of accelerator scientists and engineers

    International Nuclear Information System (INIS)

    Barletta, William A.

    2008-01-01

    Only a handful of universities in the US offer any formal training in accelerator science. The United States Particle Accelerator School (USPAS) is National Graduate Educational Program that has developed a highly successful educational paradigm that, over the past twenty-years, has granted more university credit in accelerator / beam science and technology than any university in the world. Sessions are held twice annually, hosted by major US research universities that approve course credit, certify the USPAS faculty, and grant course credit. The USPAS paradigm is readily extensible to other rapidly developing, crossdisciplinary research areas such as high energy density physics

  7. SSC accelerator availability allocation

    International Nuclear Information System (INIS)

    Dixon, K.T.; Franciscovich, J.

    1991-03-01

    Superconducting Super Collider (SSC) operational availability is an area of major concern, judged by the Central Design Group to present such risk that use of modern engineering tools would be essential to program success. Experience has shown that as accelerator beam availability falls below about 80%, efficiency of physics experiments degrades rapidly due to inability to maintain adequate coincident accelerator and detector operation. For this reason, the SSC availability goal has been set at 80%, even though the Fermi National Accelerator Laboratory accelerator, with a fraction of the SSC's complexity, has only recently approached that level. This paper describes the allocation of the top-level goal to part-level reliability and maintainability requirements, and it gives the results of parameter sensitivity studies designed to help identify the best approach to achieve the needed system availability within funding and schedule constraints. 1 ref., 12 figs., 4 tabs

  8. An unofficial history of Japanese accelerators. Part four

    International Nuclear Information System (INIS)

    Inoue, Makoto

    2005-01-01

    History of accelerator development in Japan is overviewed for a period after 1980. In the first part, big accelerator projects including Japan-U.S. Science and Technology Cooperation Program, participation in SSC project, Big Hadron Project and RCNP ring cyclotron project are looked back. In the second part, the spread of small- and medium-scale accelerator utilization are overviewed. The third part is devoted to view the relation between the atomic energy research and accelerators. Organizations of Japanese accelerator society are surveyed in the last section. (K.Y.)

  9. General aspects of installations for Paje accelerator

    International Nuclear Information System (INIS)

    Goncalez, O.L.; Yanagihara, L.S.

    1985-01-01

    It is done the preliminary proposal for a 180 MeV/50 Kw linear electron accelerator facility, to be used as a pulsed neutron source. Some technical and economic aspects of this facility in the Instituto de Estudos Avancados' accelerator technology program are discussed. (Author) [pt

  10. Continuing studies of the plasma beat wave accelerator

    International Nuclear Information System (INIS)

    Joshi, C.

    1990-01-01

    This is a proposal for the release of third year funds for the ''Plasma Beat Wave Accelerator'' program (PBWA) at UCLA under the direction of Professor C. Joshi. This report is also a summary of progress on this project since March 1990; i.e., the date of the last report to the DOE. Once again we note that although the program is for historical reasons called the Plasma Beat Wave Accelerator Program, our group is active in all areas of applications of lasers and plasmas in future high energy accelerators. These are as follows: heat gradient plasma structures; excited by plasma beat wave technique; laser wake field technique; and plasma wake field technique. Development of a photoinjector-driven, 20 MeV linac; and theoretical studies of the plasma lens and use of plasmas at the final focus

  11. A microwave inverse Cerenkov Accelerator (MICA)

    International Nuclear Information System (INIS)

    Hirshfield, Jay L.

    1999-01-01

    The objective of this Phase II SBIR research program was to complete the final design originated during Phase I for a prototype Microwave Inverse Cerenkov Accelerator (MICA), to fabricate the-prototype MICA, and to test its performance as an electron accelerator. This report contains details of the design, predictions of accelerator performance, results of cold tests on the MICA structure, and details of the installation of MICA on the Yale Beam Physics Laboratory 6-MeV beamline. Discussion of future work is also included

  12. Accelerated Characterization of Polymer Properties

    Energy Technology Data Exchange (ETDEWEB)

    R. Wroczynski; l. Brewer; D. Buckley; M. Burrell; R. Potyrailo

    2003-07-30

    This report describes the efforts to develop a suite of microanalysis techniques that can rapidly measure a variety of polymer properties of industrial importance, including thermal, photo-oxidative, and color stability; as well as ductility, viscosity, and mechanical and antistatic properties. Additional goals of the project were to direct the development of these techniques toward simultaneous measurements of multiple polymer samples of small size in real time using non-destructive and/or parallel or rapid sequential measurements, to develop microcompounding techniques for preparing polymers with additives, and to demonstrate that samples prepared in the microcompounder could be analyzed directly or used in rapid off-line measurements. These enabling technologies are the crucial precursors to the development of high-throughput screening (HTS) methodologies for the polymer additives industry whereby the rate of development of new additives and polymer formulations can be greatly accelerated.

  13. Accelerated Reader[R]: What Are the Lasting Effects on the Reading Habits of Middle School Students Exposed to Accelerated Reader[R] in Elementary Grades?

    Science.gov (United States)

    Pavonetti, Linda M.; Brimmer, Kathryn M.; Cipielewski, James F.

    Promoted by effective advertising and disseminated by word of mouth, many schools have adopted Accelerated Reader[R] as a supplementary reading program or as their primary reading program. Accelerated Reader[R]'s philosophy is that by using the system, students are motivated to read more and better books. A study investigated whether seventh grade…

  14. Sequential combination of k-t principle component analysis (PCA) and partial parallel imaging: k-t PCA GROWL.

    Science.gov (United States)

    Qi, Haikun; Huang, Feng; Zhou, Hongmei; Chen, Huijun

    2017-03-01

    k-t principle component analysis (k-t PCA) is a distinguished method for high spatiotemporal resolution dynamic MRI. To further improve the accuracy of k-t PCA, a combination with partial parallel imaging (PPI), k-t PCA/SENSE, has been tested. However, k-t PCA/SENSE suffers from long reconstruction time and limited improvement. This study aims to improve the combination of k-t PCA and PPI on both reconstruction speed and accuracy. A sequential combination scheme called k-t PCA GROWL (GRAPPA operator for wider readout line) was proposed. The GRAPPA operator was performed before k-t PCA to extend each readout line into a wider band, which improved the condition of the encoding matrix in the following k-t PCA reconstruction. k-t PCA GROWL was tested and compared with k-t PCA and k-t PCA/SENSE on cardiac imaging. k-t PCA GROWL consistently resulted in better image quality compared with k-t PCA/SENSE at high acceleration factors for both retrospectively and prospectively undersampled cardiac imaging, with a much lower computation cost. The improvement in image quality became greater with the increase of acceleration factor. By sequentially combining the GRAPPA operator and k-t PCA, the proposed k-t PCA GROWL method outperformed k-t PCA/SENSE in both reconstruction speed and accuracy, suggesting that k-t PCA GROWL is a better combination scheme than k-t PCA/SENSE. Magn Reson Med 77:1058-1067, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  15. The status of the tandem accelerator ANTARES

    Energy Technology Data Exchange (ETDEWEB)

    Fallon, J.; Boldeman, J.; Cohen, D.; Tuniz, C.; Ellis, P. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    The ANTARES facility at the Lucas Heights Research Laboratories has now operated for 4 years. A research program in Accelerator Mass Spectrometry, lon Beam Analysis and small scale radioisotope production has been pursued. During the same period, the accelerator has been significantly upgraded from the configuration which existed at Rutgers University, NJ, USA, before shipment to Australia in 1989. AMS measurement techniques of several long lived isotopes have been developed for environmental, industry and biomedical applications. Both the experimental program and the engineering developments are discussed further.

  16. The status of the tandem accelerator ANTARES

    Energy Technology Data Exchange (ETDEWEB)

    Fallon, J; Boldeman, J; Cohen, D; Tuniz, C; Ellis, P [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    The ANTARES facility at the Lucas Heights Research Laboratories has now operated for 4 years. A research program in Accelerator Mass Spectrometry, lon Beam Analysis and small scale radioisotope production has been pursued. During the same period, the accelerator has been significantly upgraded from the configuration which existed at Rutgers University, NJ, USA, before shipment to Australia in 1989. AMS measurement techniques of several long lived isotopes have been developed for environmental, industry and biomedical applications. Both the experimental program and the engineering developments are discussed further.

  17. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...

  18. Sequential logic analysis and synthesis

    CERN Document Server

    Cavanagh, Joseph

    2007-01-01

    Until now, there was no single resource for actual digital system design. Using both basic and advanced concepts, Sequential Logic: Analysis and Synthesis offers a thorough exposition of the analysis and synthesis of both synchronous and asynchronous sequential machines. With 25 years of experience in designing computing equipment, the author stresses the practical design of state machines. He clearly delineates each step of the structured and rigorous design principles that can be applied to practical applications. The book begins by reviewing the analysis of combinatorial logic and Boolean a

  19. Material studies in the frame of CLIC Accelerating structures production conducted within the Mechanics program together with Metso Oy

    CERN Document Server

    Nurminen, Janne

    2012-01-01

    MeChanICs (Marie Curie Linking Industry to CERN) is an Industry to Academia Partnership and Pathways (IAPP) platform for precision manufacturing knowledge exchange bringing together five Finnish manufacturing companies with Helsinki Insitute of Physics (HIP) and CERN. The scientific objective of MeChanICs project is to contribute to the manufacturing RTD of CLIC enabling technologies. The focus is on the design, materials, machining, brazing and assembly of A CLIC accelerating structure. This study deals with the materials work package of the program and wants to explore the following items: 1) producing copper accelerating structures for CLIC from raw copper powder by near net shape hot isostatic pressing (HIP). 2) The feasibility to use HIP diffusion bonding of the accelerator structures as a function of surface quality and applied temperature and pressure. 3) Brazing for CLIC AS auxiliary systems, like water cooling or damping manifolds, to the disc stack by coating one of the brazing partners with an enab...

  20. Simulation of a medical linear accelerator for teaching purposes.

    Science.gov (United States)

    Anderson, Rhys; Lamey, Michael; MacPherson, Miller; Carlone, Marco

    2015-05-08

    Simulation software for medical linear accelerators that can be used in a teaching environment was developed. The components of linear accelerators were modeled to first order accuracy using analytical expressions taken from the literature. The expressions used constants that were empirically set such that realistic response could be expected. These expressions were programmed in a MATLAB environment with a graphical user interface in order to produce an environment similar to that of linear accelerator service mode. The program was evaluated in a systematic fashion, where parameters affecting the clinical properties of medical linear accelerator beams were adjusted independently, and the effects on beam energy and dose rate recorded. These results confirmed that beam tuning adjustments could be simulated in a simple environment. Further, adjustment of service parameters over a large range was possible, and this allows the demonstration of linear accelerator physics in an environment accessible to both medical physicists and linear accelerator service engineers. In conclusion, a software tool, named SIMAC, was developed to improve the teaching of linear accelerator physics in a simulated environment. SIMAC performed in a similar manner to medical linear accelerators. The authors hope that this tool will be valuable as a teaching tool for medical physicists and linear accelerator service engineers.

  1. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This section is concerned with the operation of both the tandem-linac system and the Dynamitron, two accelerators that are used for entirely different research. Developmental activities associated with the tandem and the Dynamitron are also treated here, but developmental activities associated with the superconducting linac are covered separately because this work is a program of technology development in its own right

  2. Accelerator Operators and Software Development

    International Nuclear Information System (INIS)

    April Miller; Michele Joyce

    2001-01-01

    At Thomas Jefferson National Accelerator Facility, accelerator operators perform tasks in their areas of specialization in addition to their machine operations duties. One crucial area in which operators contribute is software development. Operators with programming skills are uniquely qualified to develop certain controls applications because of their expertise in the day-to-day operation of the accelerator. Jefferson Lab is one of the few laboratories that utilizes the skills and knowledge of operators to create software that enhances machine operations. Through the programs written; by operators, Jefferson Lab has improved machine efficiency and beam availability. Because many of these applications involve automation of procedures and need graphical user interfaces, the scripting language Tcl and the Tk toolkit have been adopted. In addition to automation, some operator-developed applications are used for information distribution. For this purpose, several standard web development tools such as perl, VBScript, and ASP are used. Examples of applications written by operators include injector steering, spin angle changes, system status reports, magnet cycling routines, and quantum efficiency measurements. This paper summarizes how the unique knowledge of accelerator operators has contributed to the success of the Jefferson Lab control system. *This work was supported by the U.S. DOE contract No. DE-AC05-84-ER40150

  3. Sequential optimization of approximate inhibitory rules relative to the length, coverage and number of misclassifications

    KAUST Repository

    Alsolami, Fawaz

    2013-01-01

    This paper is devoted to the study of algorithms for sequential optimization of approximate inhibitory rules relative to the length, coverage and number of misclassifications. Theses algorithms are based on extensions of dynamic programming approach. The results of experiments for decision tables from UCI Machine Learning Repository are discussed. © 2013 Springer-Verlag.

  4. Pelletron ion accelerator facilities at Inter University Accelerator Centre

    International Nuclear Information System (INIS)

    Chopra, S.

    2011-01-01

    Inter University Accelerator Centre has two tandem ion accelerators, 15UD Pelletron and 5SDH-2 Pelletron, for use in different areas of research. Recently Accelerator Mass Spectrometry facility has also been added to to the existing experimental facilities of 15UD Pelletron. In these years many modifications and up gradations have been performed to 15UD Pelletron facility. A new MCSNICS ion source has been procured to produce high currents for AMS program. Two foils stripper assemblies ,one each before and after analyzing magnet, have also been added for producing higher charge state beams for LINAC and for experiments requiring higher charge states of accelerated beams. A new 1.7 MV Pelletron facility has also been recently installed at IUAC and it is equipped with RBS and Channelling experimental facility. There are two beam lines installed in the system and five more beam lines can be added to the system. A clean chemistry laboratory with all the modern facilities has also been developed at IUAC for the chemical processing of samples prior to the AMS measurements. The operational description of the Pelletron facilities, chemical processing of samples, methods of measurements and results of AMS measurements are being presented. (author)

  5. Integration of complex-wide mixed low-level waste activities for program acceleration and optimization

    International Nuclear Information System (INIS)

    McKenney, D.E.

    1998-01-01

    In July 1996, the US Department of Energy (DOE) chartered a contractor-led effort to develop a suite of technically defensible, integrated alternatives which would allow the Environmental Management program to accomplish its mission objectives in an accelerated fashion and at a reduced cost. These alternatives, or opportunities, could then be evaluated by DOE and stakeholders for possible implementation, given precursor requirements (regulatory changes, etc.) could be met and benefits to the Complex realized. This contractor effort initially focused on six waste types, one of which was Mixed Low-Level Waste (MLLW). Many opportunities were identified by the contractor team for integrating MLLW activities across the DOE Complex. These opportunities were further narrowed to six that had the most promise for implementation and savings to the DOE Complex. The opportunities include six items: (1) the consolidation of individual site analytical services procurement efforts, (2) the consolidation of individual site MLLW treatment services procurement efforts, (3) establishment of ''de minimus'' radioactivity levels, (4) standardization of characterization requirements, (5) increased utilization of existing DOE treatment facilities, and (6) using a combination of DOE and commercial MLLW disposal capacity. The results of the integration effort showed that by managing MLLW activities across the DOE Complex as a cohesive unit rather than as independent site efforts, the DOE could improve the rate of progress toward meeting its objectives and reduce its overall MLLW program costs. Savings potential for MLLW, if the identified opportunities could be implemented, could total $224 million or more. Implementation of the opportunities also could result in the acceleration of the MLLW ''work off schedule'' across the DOE Complex by five years

  6. Graduate Student Program in Materials and Engineering Research and Development for Future Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Spentzouris, Linda [Illinois Inst. of Technology, Chicago, IL (United States)

    2016-07-07

    The objective of the proposal was to develop graduate student training in materials and engineering research relevant to the development of particle accelerators. Many components used in today's accelerators or storage rings are at the limit of performance. The path forward in many cases requires the development of new materials or fabrication techniques, or a novel engineering approach. Often, accelerator-based laboratories find it difficult to get top-level engineers or materials experts with the motivation to work on these problems. The three years of funding provided by this grant was used to support development of accelerator components through a multidisciplinary approach that cut across the disciplinary boundaries of accelerator physics, materials science, and surface chemistry. The following results were achieved: (1) significant scientific results on fabrication of novel photocathodes, (2) application of surface science and superconducting materials expertise to accelerator problems through faculty involvement, (3) development of instrumentation for fabrication and characterization of materials for accelerator components, (4) student involvement with problems at the interface of material science and accelerator physics.

  7. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  8. Effects of working memory and reading acceleration training on improving working memory abilities and reading skills among third graders.

    Science.gov (United States)

    Nevo, Einat; Breznitz, Zvia

    2014-01-01

    Working memory (WM) plays a crucial role in supporting learning, including reading. This study investigated the influence of reading acceleration and WM training programs on improving reading skills and WM abilities. Ninety-seven children in third grade were divided into three study groups and one control group. The three study groups each received a different combination of two training programs: only reading acceleration, WM followed by reading acceleration, and reading acceleration followed by WM. All training programs significantly improved reading skills and WM abilities. Compared with the control group, the group trained with only the reading acceleration program improved word accuracy, whereas the groups trained with a combination of reading and WM programs improved word and pseudo-word fluency. The reading-acceleration-alone group and the WM-program-followed-by-reading-acceleration group improved phonological complex memory. We conclude that a training program that combines a long reading acceleration program and a short WM program is the most effective for improving the abilities most related to scholastic achievement.

  9. EVALUASI PROGRAM AKSELERASI DI SMP NEGERI KOTA AMBON

    Directory of Open Access Journals (Sweden)

    David Tuhurima

    2016-06-01

    Full Text Available This research is aimed to evaluate acceleration program in SMP Negeri 6 Ambon which is include four components such as: (1Context (2Input (3 Process, and (4Product. This is an evaluative research using descriptive analysis. This research informants are principals, viceprincipals, program coordinators, teachers, school committees, parents, and students accelerated program. Research sites in SMP Negeri 6 Ambon. The data is collected using interview, observation and documentation study techniques. For the data validation, this research used triangulation of sources and techniques. The results shows that, from context, the implementation of the acceleration program is a school’s initiative as an effort to address the needs and provide the education services for special smart learners (IQ  130 as well as the effectiveness of school facilities and infrastructure utilization. From the point of input including: (a the program policy, the school has permission from the department as the juridical basis for accelerated program implementation, and (b planning program: recruitment of learners are in accordance with the criteria, curriculum acceleration program already differentiated, educators (teachers already meets the qualifications and criteria as teacher in class acceleration, infrastructure and financing program is sufficient to support the accelerated program. In terms of Process, acceleration program in SMP Negeri 6 Ambon has been implemented in accordance with the planning program, although there are still some shortcomings and obstacles. Recruitment of learners already implemented, curriculum adjustments will only be visible on the implementation of the teaching and learning activities, educators (teachers are still there who do not meet the qualifications and criteria as a teacher in class acceleration, infrastructure is not sufficient to support an accelerated program of activities, and financing programs that is still lacking. The

  10. Radiation safety training for accelerator facilities

    International Nuclear Information System (INIS)

    Trinoskey, P.A.

    1997-02-01

    In November 1992, a working group was formed within the U.S. Department of Energy's (DOE's) accelerator facilities to develop a generic safety training program to meet the basic requirements for individuals working in accelerator facilities. This training, by necessity, includes sections for inserting facility-specific information. The resulting course materials were issued by DOE as a handbook under its technical standards in 1996. Because experimenters may be at a facility for only a short time and often at odd times during the day, the working group felt that computer-based training would be useful. To that end, Lawrence Livermore National Laboratory (LLNL) and Argonne National Laboratory (ANL) together have developed a computer-based safety training program for accelerator facilities. This interactive course not only enables trainees to receive facility- specific information, but time the training to their schedule and tailor it to their level of expertise

  11. Hazardous Traffic Event Detection Using Markov Blanket and Sequential Minimal Optimization (MB-SMO

    Directory of Open Access Journals (Sweden)

    Lixin Yan

    2016-07-01

    Full Text Available The ability to identify hazardous traffic events is already considered as one of the most effective solutions for reducing the occurrence of crashes. Only certain particular hazardous traffic events have been studied in previous studies, which were mainly based on dedicated video stream data and GPS data. The objective of this study is twofold: (1 the Markov blanket (MB algorithm is employed to extract the main factors associated with hazardous traffic events; (2 a model is developed to identify hazardous traffic event using driving characteristics, vehicle trajectory, and vehicle position data. Twenty-two licensed drivers were recruited to carry out a natural driving experiment in Wuhan, China, and multi-sensor information data were collected for different types of traffic events. The results indicated that a vehicle’s speed, the standard deviation of speed, the standard deviation of skin conductance, the standard deviation of brake pressure, turn signal, the acceleration of steering, the standard deviation of acceleration, and the acceleration in Z (G have significant influences on hazardous traffic events. The sequential minimal optimization (SMO algorithm was adopted to build the identification model, and the accuracy of prediction was higher than 86%. Moreover, compared with other detection algorithms, the MB-SMO algorithm was ranked best in terms of the prediction accuracy. The conclusions can provide reference evidence for the development of dangerous situation warning products and the design of intelligent vehicles.

  12. Sequential Quadratic Programming Algorithms for Optimization

    Science.gov (United States)

    1989-08-01

    quadratic program- ma ng (SQ(2l ) aIiatain.seenis to be relgarded aIs tie( buest choice for the solution of smiall. dlense problema (see S tour L)toS...For the step along d, note that a < nOing + 3 szH + i3.ninA A a K f~Iz,;nd and from Id1 _< ,,, we must have that for some /3 , np , 11P11 < dn"p. 5.2...Nevertheless, many of these problems are considered hard to solve. Moreover, for some of these problems the assumptions made in Chapter 2 to establish the

  13. Uses of accelerators in energy R and D

    International Nuclear Information System (INIS)

    Saltmarsh, M.J.

    1975-01-01

    At many laboratories an increasing emphasis is being placed on energy-related research, often at the expense of more basic programs. The effects of this change can be clearly seen at accelerator laboratories, where tools traditionally reserved for nuclear and particle physicists are being applied in areas such as radiation damage, nuclear waste management, and materials science. The success of accelerator-based work in these fields is reflected by the increasing interest in proposals for new facilities devoted entirely to applied programs. Current proposals include various forms of intense neutron sources for fusion-related work, synchrotron x-ray sources for materials studies, and even the use of accelerators for large-scale nuclear waste disposal. (45 referencs) (U.S.)

  14. Generalized infimum and sequential product of quantum effects

    International Nuclear Information System (INIS)

    Li Yuan; Sun Xiuhong; Chen Zhengli

    2007-01-01

    The quantum effects for a physical system can be described by the set E(H) of positive operators on a complex Hilbert space H that are bounded above by the identity operator I. For A, B(set-membership sign)E(H), the operation of sequential product A(convolution sign)B=A 1/2 BA 1/2 was proposed as a model for sequential quantum measurements. A nice investigation of properties of the sequential product has been carried over [Gudder, S. and Nagy, G., 'Sequential quantum measurements', J. Math. Phys. 42, 5212 (2001)]. In this note, we extend some results of this reference. In particular, a gap in the proof of Theorem 3.2 in this reference is overcome. In addition, some properties of generalized infimum A sqcap B are studied

  15. Nodal in computerized control systems of accelerators

    International Nuclear Information System (INIS)

    Kagarmanov, A.A.; Koval'tsov, V.I.; Korobov, S.A.

    1994-01-01

    Brief description of the Nodal language programming structure is presented. Its possibilities as high-level programming language for accelerator control systems are considered. The status of the Nodal language in the HEPI is discussed. 3 refs

  16. Accelerator Mass Spectrometry at the Nuclear Science Laboratory: Applications to Nuclear Astrophysics

    Science.gov (United States)

    Collon, P.; Bauder, W.; Bowers, M.; Lu, W.; Ostdiek, K.; Robertson, D.

    The Accelerator Mass Spectrometry (AMS) program at the Nuclear Science Laboratory of the University of Notre Dame is focused on measurements related to galactic radioactivity and to nucleosynthesis of main stellar burning as well as the production of so called Short-Lived Radionuclides (SLRs) in the Early Solar System (ESS). The research program is based around the 11MV FN tandem accelerator and the use of the gas-filled magnet technique for isobar separation. Using a technique that evolved from radiocarbon dating, this paper presents a number of research programs that rely on the use of an 11MV tandem accelerator at the center of the AMS program.

  17. Light Ion Biomedical Research Accelerator LIBRA

    International Nuclear Information System (INIS)

    Gough, R.A.

    1987-01-01

    LIBRA is a concept to place a light-ion, charged-particle facility in a hospital environment, and to dedicate it to applications in biology and medicine. There are two aspects of the program envisaged for LIBRA: a basic research effort coupled with a program in clinical applications of accelerated charged particles. The operational environment to be provided for LIBRA is one in which both of these components can coexist and flourish, and one that will promote the transfer of technology and knowledge from one to the other. In order to further investigate the prospects for a Light Ion Biomedical Research Accelerator (LIBRA), discussions are underway with the Merritt Peralta Medical Center MPMC) in Oakland CA, and the University of California at San Francisco (UCSF). In this paper, a brief discussion of the technical requirements for such a facility is given, together with an outline of the accelerator technology required. While still in a preliminary stage, it is possible nevertheless to develop an adequate working description of the type, size, performance and cost of the accelerator facilities required to meet the preliminary goals for LIBRA

  18. The Los Alamos Laser Acceleration of Particles Workshop and beginning of the advanced accelerator concepts field

    Science.gov (United States)

    Joshi, C.

    2012-12-01

    The first Advanced Acceleration of Particles-AAC-Workshop (actually named Laser Acceleration of Particles Workshop) was held at Los Alamos in January 1982. The workshop lasted a week and divided all the acceleration techniques into four categories: near field, far field, media, and vacuum. Basic theorems of particle acceleration were postulated (later proven) and specific experiments based on the four categories were formulated. This landmark workshop led to the formation of the advanced accelerator R&D program in the HEP office of the DOE that supports advanced accelerator research to this day. Two major new user facilities at Argonne and Brookhaven and several more directed experimental efforts were built to explore the advanced particle acceleration schemes. It is not an exaggeration to say that the intellectual breadth and excitement provided by the many groups who entered this new field provided the needed vitality to then recently formed APS Division of Beams and the new online journal Physical Review Special Topics-Accelerators and Beams. On this 30th anniversary of the AAC Workshops, it is worthwhile to look back at the legacy of the first Workshop at Los Alamos and the fine groundwork it laid for the field of advanced accelerator concepts that continues to flourish to this day.

  19. The first acceleration test of polarized protons in KEK PS

    International Nuclear Information System (INIS)

    Hiramatsu, Shigenori; Sato, Hikaru; Toyama, Takeshi

    1984-03-01

    The outline of the polarized proton acceleration project at KEK and the results of the first acceleration test are described. Depolarization in the 500 MeV booster synchrotron was investigated as the first step of this program. The beam polarization was measured in the 20 MeV beam transport line from the linac to the booster and in the main ring at the injection energy. About 40 % of the linac beam polarization was kept in the main ring. This acceleration test encouraged us to proceed with this program. (author)

  20. Sequential analysis in neonatal research-systematic review.

    Science.gov (United States)

    Lava, Sebastiano A G; Elie, Valéry; Ha, Phuong Thi Viet; Jacqz-Aigrain, Evelyne

    2018-05-01

    As more new drugs are discovered, traditional designs come at their limits. Ten years after the adoption of the European Paediatric Regulation, we performed a systematic review on the US National Library of Medicine and Excerpta Medica database of sequential trials involving newborns. Out of 326 identified scientific reports, 21 trials were included. They enrolled 2832 patients, of whom 2099 were analyzed: the median number of neonates included per trial was 48 (IQR 22-87), median gestational age was 28.7 (IQR 27.9-30.9) weeks. Eighteen trials used sequential techniques to determine sample size, while 3 used continual reassessment methods for dose-finding. In 16 studies reporting sufficient data, the sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674) with respect to a traditional trial. When the number of neonates finally included in the analysis was considered, the difference became significant: 35 (57%) patients (IQR 10 to 136.5, p = 0.0033). Sequential trial designs have not been frequently used in Neonatology. They might potentially be able to reduce the number of patients in drug trials, although this is not always the case. What is known: • In evaluating rare diseases in fragile populations, traditional designs come at their limits. About 20% of pediatric trials are discontinued, mainly because of recruitment problems. What is new: • Sequential trials involving newborns were infrequently used and only a few (n = 21) are available for analysis. • The sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674).

  1. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...... assumed to be normally distributed, and sequential one-sided hypothesis tests on the population standard deviation of the differences against a hypothesised value of 1.5 were performed, employing an alpha spending function. The fixed-sample analysis (N = 45) was compared with the group-sequential analysis...... strategies comprising one (at N = 23), two (at N = 15, 30), or three interim analyses (at N = 11, 23, 34), respectively, which were defined post hoc. RESULTS: When performing interim analyses with one third and two thirds of patients, sufficient agreement could be concluded after the first interim analysis...

  2. Method and apparatus for accelerating a solid mass

    International Nuclear Information System (INIS)

    Tidman, D.A.; Goldstein, Y.A.

    1984-01-01

    An axi-symmetrical projectile, having a mass ranging from fractions of a gram to kilograms, is accelerated to velocities in the range of 10 5 to 10 7 centimeters per second by a propelling force produced by a plasma resulting from electric discharge. The discharge is imploded against the projectile surface so lines of the magnetic fields are approximately azimuthal around the projectile axis. The projectile is tapered so it experiences a net, stable axial accelerating force along the accelerator axis by the combined action of the magnetic field producing radially directed momentum and pressure on the plasma, the interaction of the magnetic field and ions induced by the plasma on the surface, as well as material the plasma ablates from the surface. The plasma discharge is initiated either in low density background gas between anode and cathode of a discharge module, or along an insulator surface between the electrodes in low density background gas. Alternatively, in either of these situations the discharge can be initiated in a gas which is produced by ablation of the projectile surface. In an alternative situation, the projectile acts as a switch for triggering discharges. Eddy current heating of the projectile is minimized by shaping the discharge current pulse so the plasma has a relatively weak magnetic field when it arrives at the surface, or by making the projectile electrically non-conducting. To provide a long acceleration path, a series of modules is aligned. In one embodiment, the projectile position, as it advances between modules, is sensed and discharges are switched on sequentially in the modules

  3. Operation of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program

  4. Comparison of ablation centration after bilateral sequential versus simultaneous LASIK.

    Science.gov (United States)

    Lin, Jane-Ming; Tsai, Yi-Yu

    2005-01-01

    To compare ablation centration after bilateral sequential and simultaneous myopic LASIK. A retrospective randomized case series was performed of 670 eyes of 335 consecutive patients who had undergone either bilateral sequential (group 1) or simultaneous (group 2) myopic LASIK between July 2000 and July 2001 at the China Medical University Hospital, Taichung, Taiwan. The ablation centrations of the first and second eyes in the two groups were compared 3 months postoperatively. Of 670 eyes, 274 eyes (137 patients) comprised the sequential group and 396 eyes (198 patients) comprised the simultaneous group. Three months post-operatively, 220 eyes of 110 patients (80%) in the sequential group and 236 eyes of 118 patients (60%) in the simultaneous group provided topographic data for centration analysis. For the first eyes, mean decentration was 0.39 +/- 0.26 mm in the sequential group and 0.41 +/- 0.19 mm in the simultaneous group (P = .30). For the second eyes, mean decentration was 0.28 +/- 0.23 mm in the sequential group and 0.30 +/- 0.21 mm in the simultaneous group (P = .36). Decentration in the second eyes significantly improved in both groups (group 1, P = .02; group 2, P sequential group and 0.32 +/- 0.18 mm in the simultaneous group (P = .33). The difference of ablation center angles between the first and second eyes was 43.2 sequential group and 45.1 +/- 50.8 degrees in the simultaneous group (P = .42). Simultaneous bilateral LASIK is comparable to sequential surgery in ablation centration.

  5. A Survey of Multi-Objective Sequential Decision-Making

    NARCIS (Netherlands)

    Roijers, D.M.; Vamplew, P.; Whiteson, S.; Dazeley, R.

    2013-01-01

    Sequential decision-making problems with multiple objectives arise naturally in practice and pose unique challenges for research in decision-theoretic planning and learning, which has largely focused on single-objective settings. This article surveys algorithms designed for sequential

  6. Sequential lineups: shift in criterion or decision strategy?

    Science.gov (United States)

    Gronlund, Scott D

    2004-04-01

    R. C. L. Lindsay and G. L. Wells (1985) argued that a sequential lineup enhanced discriminability because it elicited use of an absolute decision strategy. E. B. Ebbesen and H. D. Flowe (2002) argued that a sequential lineup led witnesses to adopt a more conservative response criterion, thereby affecting bias, not discriminability. Height was encoded as absolute (e.g., 6 ft [1.83 m] tall) or relative (e.g., taller than). If a sequential lineup elicited an absolute decision strategy, the principle of transfer-appropriate processing predicted that performance should be best when height was encoded absolutely. Conversely, if a simultaneous lineup elicited a relative decision strategy, performance should be best when height was encoded relatively. The predicted interaction was observed, providing direct evidence for the decision strategies explanation of what happens when witnesses view a sequential lineup.

  7. Using Advanced Mixed Waste Treatment Technology To Meet Accelerated Cleanup Program Milestones

    International Nuclear Information System (INIS)

    Larsen, P.J.; Garcia, J.; Estes, C.H.; Palmer, C.R.; Meyers, G.S.

    2006-01-01

    Some DOE Complex facilities are entering the late stages of facility closure. As waste management operations are completed at these sites, remaining inventories of legacy mixed wastes must be finally disposed. These wastes have unique physical, chemical and radiological properties that have made their management troublesome, and hence why they have remained on site until this late stage of closure. Some of these wastes have had no approved or practical treatment alternative until just recently. Results are provided from using advanced mixed waste treatment technology to perform two treatment campaigns on these legacy wastes. Combinations of macro-encapsulation, vacuum thermal desorption (VTD), and chemical stabilization, with off-site incineration of the organic condensate, provided a complete solution to the problem wastes. One program included approximately 1,900 drums of material from the Fernald Environmental Management Project. Another included approximately 1,200 drums of material from the Accelerated Cleanup Program at the Oak Ridge Reservation. Both of these campaigns were conducted under tight time schedules and demanding specifications, and were performed in a matter of only a few months each. Coordinated rapid waste shipment, flexible permitting and waste acceptance criteria, adequate waste receiving and storage capacity, versatile feed preparation and sorting capability, robust treatment technology with a broad feed specification, and highly reliable operations were all valuable components to successful accomplishment of the project requirements. Descriptions of the waste are provided; material that was difficult or impossible to treat in earlier phases of site closure. These problem wastes included: 1) the combination of special nuclear materials mixed with high organic chemical content and/or mercury, 2) high toxic metal content mixed with high organic chemical content, and 3) very high organic chemical content mixed with debris, solids and sludge

  8. Cellular Basis for ADT-Induced Acceleration of Sarcopenia

    Science.gov (United States)

    2015-10-01

    1 AWARD NUMBER: W81XWH-14-1-0454 TITLE: Cellular Basis for ADT-Induced Acceleration of Sarcopenia PRINCIPAL INVESTIGATOR: Joe V...AND SUBTITLE Cellular Basis for ADT-Induced Acceleration of Sarcopenia 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-14-1-0454 5c. PROGRAM...cell function and thereby regenerative capability contribute to the acceleration of sarcopenia observed in prostate cancer patients undergoing ADT

  9. Effortless assignment with 4D covariance sequential correlation maps.

    Science.gov (United States)

    Harden, Bradley J; Mishra, Subrata H; Frueh, Dominique P

    2015-11-01

    Traditional Nuclear Magnetic Resonance (NMR) assignment procedures for proteins rely on preliminary peak-picking to identify and label NMR signals. However, such an approach has severe limitations when signals are erroneously labeled or completely neglected. The consequences are especially grave for proteins with substantial peak overlap, and mistakes can often thwart entire projects. To overcome these limitations, we previously introduced an assignment technique that bypasses traditional pick peaking altogether. Covariance Sequential Correlation Maps (COSCOMs) transform the indirect connectivity information provided by multiple 3D backbone spectra into direct (H, N) to (H, N) correlations. Here, we present an updated method that utilizes a single four-dimensional spectrum rather than a suite of three-dimensional spectra. We demonstrate the advantages of 4D-COSCOMs relative to their 3D counterparts. We introduce improvements accelerating their calculation. We discuss practical considerations affecting their quality. And finally we showcase their utility in the context of a 52 kDa cyclization domain from a non-ribosomal peptide synthetase. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Assessment of the adequacy of US accelerator technology for Department of Energy missions

    International Nuclear Information System (INIS)

    Gerry, E.T.; Mani, S.A.

    1983-09-01

    Accelerator technology has made enormous impact across a wide field of research, industrial, and commercial endeavor and new developments are projected to broaden this technology transfer and open up new applications not previously possible or economically attractive. At the same time, however, the broad multi-agency base of support for the development of accelerator technology has largely evaporated leaving the program with the Department of Energy (DOE) Office of Energy Research (OER) as the only major National effort not directed at specific narrow applications. In order to continue to reap the benefits and spin-offs from this area of technology, an expanded long-term funding committment is vigorously endorsed since there appear to be major payoff potential in several areas of national need. Three specific recommendations are made that would accelerate the projected benefits from accelerator technology. An expanded effort should be undertaken to develop the key technologies of high brightness, high current, large area, long life, reliable ion, electron and RF sources along with associated studies directed toward accelerator design optimization. A centralized computational facility with a dedicated staff and library of programs for simulation of accelerator phenomenology should be created similar to that for the magnetic fusion program. Advanced accelerator R and D should be funded at a steady level to support a long range accelerator applications program

  11. Programing Procedures Manual (PPM).

    Science.gov (United States)

    1981-12-15

    terms ’reel’, ’unit’, and ’volume’ are synonymous and completely interchangeable in the CLOSE statement. Treatment of sequential mass storage files is...logically equivalent to the treatment of a file on tape or analogous sequential media. * For the purpose of showing the effect of various types of CLOSE...Overlay Area CA6 Address of Abend Relative to beginning of overlay segment The programer can now refer to the compile source listing for the overlay

  12. Transmutation of fission products through accelerator

    International Nuclear Information System (INIS)

    Nakamura, H.; Tani, S.; Takahashi, T.; Yamamura, O.

    1995-01-01

    The transmutation of fission products through particle accelerators has been studied under the OMEGA program. The photonuclear reaction has also been investigated to be applied to transmuting long-lived fission products, such as Cesium and Strontium, which have difficulties on reaction with neutrons due to its so small cross section. It is applicable for the transmutation if the energy balance can be improved with a monochromatic gamma rays in the range of the Giant Dipole Resonance generated through an excellent high current electron linear accelerator. The feasibility studies are being conducted on the transmutation system using it through an electron accelerator. (authors)

  13. Effect of Rayleigh accelerations applied to an initially moving fluid. [in circular cylinders under low gravity associated with space flight

    Science.gov (United States)

    Dressler, R. F.; Robertson, S. J.; Spradley, L. W.

    1982-01-01

    The General Interpolant Method computer code was used to analyze two-dimensional unsteady thermal convection in circular cylinders under variable low-g conditions associated with space flight. When an acceleration vector was applied parallel to the thermal gradient, in the case of a fluid at rest, no convection resulted for the stable direction, and an instability led to Rayleigh convection for the opposite direction. However, when the acceleration had a component orthogonal to the gradient, convection resulted at any Rayleigh number. The effect on convection of both types of acceleration, applied concurrently or sequentially, was investigated, including the case when the resultant vector varied in direction with time. An analysis of experimental results shows that for space flight conditions, the Rayleigh accelerations induce significant, but not dominating, changes in the established convection even when the Rayleigh number is less than critical.

  14. How to Read the Tractatus Sequentially

    Directory of Open Access Journals (Sweden)

    Tim Kraft

    2016-11-01

    Full Text Available One of the unconventional features of Wittgenstein’s Tractatus Logico-Philosophicus is its use of an elaborated and detailed numbering system. Recently, Bazzocchi, Hacker und Kuusela have argued that the numbering system means that the Tractatus must be read and interpreted not as a sequentially ordered book, but as a text with a two-dimensional, tree-like structure. Apart from being able to explain how the Tractatus was composed, the tree reading allegedly solves exegetical issues both on the local (e. g. how 4.02 fits into the series of remarks surrounding it and the global level (e. g. relation between ontology and picture theory, solipsism and the eye analogy, resolute and irresolute readings. This paper defends the sequential reading against the tree reading. After presenting the challenges generated by the numbering system and the two accounts as attempts to solve them, it is argued that Wittgenstein’s own explanation of the numbering system, anaphoric references within the Tractatus and the exegetical issues mentioned above do not favour the tree reading, but a version of the sequential reading. This reading maintains that the remarks of the Tractatus form a sequential chain: The role of the numbers is to indicate how remarks on different levels are interconnected to form a concise, surveyable and unified whole.

  15. Probabilistic Programming : A True Verification Challenge

    NARCIS (Netherlands)

    Katoen, Joost P.; Finkbeiner, Bernd; Pu, Geguang; Zhang, Lijun

    2015-01-01

    Probabilistic programs [6] are sequential programs, written in languages like C, Java, Scala, or ML, with two added constructs: (1) the ability to draw values at random from probability distributions, and (2) the ability to condition values of variables in a program through observations. For a

  16. Accelerators as Authentic Training Experiences for Nascent Entrepreneurs

    Science.gov (United States)

    Miles, Morgan P.; de Vries, Huibert; Harrison, Geoff; Bliemel, Martin; de Klerk, Saskia; Kasouf, Chick J.

    2017-01-01

    Purpose: The purpose of this paper is to address the role of accelerators as authentic learning-based entrepreneurial training programs. Accelerators facilitate the development and assessment of entrepreneurial competencies in nascent entrepreneurs through the process of creating a start-up venture. Design/methodology/approach: Survey data from…

  17. A minimax procedure in the context of sequential mastery testing

    NARCIS (Netherlands)

    Vos, Hendrik J.

    1999-01-01

    The purpose of this paper is to derive optimal rules for sequential mastery tests. In a sequential mastery test, the decision is to classify a subject as a master or a nonmaster, or to continue sampling and administering another random test item. The framework of minimax sequential decision theory

  18. Operation of the Brookhaven national laboratory accelerator test facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; Van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program. (Author) 5 refs., 4 figs., tab

  19. Inverse Cerenkov laser acceleration experiment at ATF

    International Nuclear Information System (INIS)

    Wang, X.J.; Pogorelsky, I.; Fernow, R.; Kusche, K.P.; Liu, Y.; Kimura, W.D.; Kim, G.H.; Romea, R.D.; Steinhauer, L.C.

    1994-01-01

    Inverse Cerenkov laser acceleration was demonstrated using an axicon optical system at the Brookhaven Accelerator Test Facility (ATF). The ATF S-band linac and a high power 10.6 μm CO 2 laser were used for the experiment. Experimental arrangement and the laser and the electron beams synchronization are discussed. The electrons were accelerated more than 0.7 MeV for a 34 MW CO 2 laser power. More than 3.7 MeV acceleration was measured with 0.7 GW CO 2 laser power, which is more than 20 times of the previous ICA experiment. The experimental results are compared with computer program TRANSPORT simulations

  20. SLAC accelerator operations report: 1992-1995

    International Nuclear Information System (INIS)

    Erickson, R.; Allen, C.W.; Inman, T.K.; Linebarger, W.; Stanek, M.

    1995-05-01

    Operational statistics for the linear accelerator programs at SLAC are presented, including run-time records for the SLC, FFTB, and fixed target programs. Also included are summaries of reliability and maintenance-related statistics and a discussion of the analysis tools used to study error messages generated by the control system

  1. Future HEP Accelerators: The US Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, Pushpalatha [Fermilab; Shiltsev, Vladimir [Fermilab

    2015-11-02

    Accelerator technology has advanced tremendously since the introduction of accelerators in the 1930s, and particle accelerators have become indispensable instruments in high energy physics (HEP) research to probe Nature at smaller and smaller distances. At present, accelerator facilities can be classified into Energy Frontier colliders that enable direct discoveries and studies of high mass scale particles and Intensity Frontier accelerators for exploration of extremely rare processes, usually at relatively low energies. The near term strategies of the global energy frontier particle physics community are centered on fully exploiting the physics potential of the Large Hadron Collider (LHC) at CERN through its high-luminosity upgrade (HL-LHC), while the intensity frontier HEP research is focused on studies of neutrinos at the MW-scale beam power accelerator facilities, such as Fermilab Main Injector with the planned PIP-II SRF linac project. A number of next generation accelerator facilities have been proposed and are currently under consideration for the medium- and long-term future programs of accelerator-based HEP research. In this paper, we briefly review the post-LHC energy frontier options, both for lepton and hadron colliders in various regions of the world, as well as possible future intensity frontier accelerator facilities.

  2. Acceleration of polarized electrons in the Bonn electron-accelerator facility ELSA

    International Nuclear Information System (INIS)

    Hoffmann, M.

    2001-12-01

    The future medium energy physics program at the electron stretcher accelerator ELSA of Bonn University mainly relies on experiments using polarized electrons in the energy range from 1 to 3.2 GeV. To prevent depolarization during acceleration in the circular accelerators several depolarizing resonances have to be corrected for. Intrinsic resonances are compensated using two pulsed betatron tune jump quadrupoles. The influence of imperfection resonances is successfully reduced applying a dynamic closed orbit correction in combination with an empirical harmonic correction on the energy ramp. Both types of resonances and the correction techniques have been studied in detail. The imperfection resonances were used to calibrate the energy of the stretcher ring with high accuracy. A new technique to extract the beam with horizontal oriented polarization was successfully installed. For all energies a polarized electron beam with more than 50% polarization can now be supplied to the experiments at ELSA, which is demonstrated by measurements using a Moeller polarimeter installed in the external beamline. (orig.)

  3. Compact toroid formation, compression, and acceleration

    International Nuclear Information System (INIS)

    Degnan, J.H.; Peterkin, R.E. Jr.; Baca, G.P.; Beason, J.D.; Bell, D.E.; Dearborn, M.E.; Dietz, D.; Douglas, M.R.; Englert, S.E.; Englert, T.J.; Hackett, K.E.; Holmes, J.H.; Hussey, T.W.; Kiuttu, G.F.; Lehr, F.M.; Marklin, G.J.; Mullins, B.W.; Price, D.W.; Roderick, N.F.; Ruden, E.L.; Sovinec, C.R.; Turchi, P.J.; Bird, G.; Coffey, S.K.; Seiler, S.W.; Chen, Y.G.; Gale, D.; Graham, J.D.; Scott, M.; Sommars, W.

    1993-01-01

    Research on forming, compressing, and accelerating milligram-range compact toroids using a meter diameter, two-stage, puffed gas, magnetic field embedded coaxial plasma gun is described. The compact toroids that are studied are similar to spheromaks, but they are threaded by an inner conductor. This research effort, named MARAUDER (Magnetically Accelerated Ring to Achieve Ultra-high Directed Energy and Radiation), is not a magnetic confinement fusion program like most spheromak efforts. Rather, the ultimate goal of the present program is to compress toroids to high mass density and magnetic field intensity, and to accelerate the toroids to high speed. There are a variety of applications for compressed, accelerated toroids including fast opening switches, x-radiation production, radio frequency (rf) compression, as well as charge-neutral ion beam and inertial confinement fusion studies. Experiments performed to date to form and accelerate toroids have been diagnosed with magnetic probe arrays, laser interferometry, time and space resolved optical spectroscopy, and fast photography. Parts of the experiment have been designed by, and experimental results are interpreted with, the help of two-dimensional (2-D), time-dependent magnetohydrodynamic (MHD) numerical simulations. When not driven by a second discharge, the toroids relax to a Woltjer--Taylor equilibrium state that compares favorably to the results of 2-D equilibrium calculations and to 2-D time-dependent MHD simulations. Current, voltage, and magnetic probe data from toroids that are driven by an acceleration discharge are compared to 2-D MHD and to circuit solver/slug model predictions. Results suggest that compact toroids are formed in 7--15 μsec, and can be accelerated intact with material species the same as injected gas species and entrained mass ≥1/2 the injected mass

  4. Multichannel, sequential or combined X-ray spectrometry

    International Nuclear Information System (INIS)

    Florestan, J.

    1979-01-01

    X-ray spectrometer qualities and defects are evaluated for sequential and multichannel categories. Multichannel X-ray spectrometer has time-coherency advantage and its results could be more reproducible; on the other hand some spatial incoherency limits low percentage and traces applications, specially when backgrounds are very variable. In this last case, sequential X-ray spectrometer would find again great usefulness [fr

  5. Single-Fraction Stereotactic Body Radiation Therapy and Sequential Gemcitabine for the Treatment of Locally Advanced Pancreatic Cancer

    International Nuclear Information System (INIS)

    Schellenberg, Devin; Kim, Jeff; Christman-Skieller, Claudia; Chun, Carlene L.; Columbo, Laurie Ann; Ford, James M.; Fisher, George A.; Kunz, Pamela L.; Van Dam, Jacques; Quon, Andrew; Desser, Terry S.; Norton, Jeffrey; Hsu, Annie; Maxim, Peter G.; Xing, Lei; Goodman, Karyn A.; Chang, Daniel T.; Koong, Albert C.

    2011-01-01

    Purpose: This Phase II trial evaluated the toxicity, local control, and overall survival in patients treated with sequential gemcitabine and linear accelerator-based single-fraction stereotactic body radiotherapy (SBRT). Methods and Materials: Twenty patients with locally advanced, nonmetastatic pancreatic adenocarcinoma were enrolled on this prospective single-institution, institutional review board-approved study. Gemcitabine was administered on Days 1, 8, and 15, and SBRT on Day 29. Gemcitabine was restarted on Day 43 and continued for 3-5 cycles. SBRT of 25 Gy in a single fraction was delivered to the internal target volume with a 2- 3-mm margin using a nine-field intensity-modulated radiotherapy technique. Respiratory gating was used to account for breathing motion. Follow-up evaluations occurred at 4-6 weeks, 10-12 weeks, and every 3 months after SBRT. Results: All patients completed SBRT and a median of five cycles of chemotherapy. Follow-up for the 2 remaining alive patients was 25.1 and 36.4 months. No acute Grade 3 or greater nonhematologic toxicity was observed. Late Grade 3 or greater toxicities occurred in 1 patient (5%) and consisted of a duodenal perforation (G4). Three patients (15%) developed ulcers (G2) that were medically managed. Overall, median survival was 11.8 months, with 1-year survival of 50% and 2-year survival of 20%. Using serial computed tomography, the freedom from local progression was 94% at 1 year. Conclusion: Linear accelerator-delivered SBRT with sequential gemcitabine resulted in excellent local control of locally advanced pancreatic cancer. Future studies will address strategies for reducing long-term duodenal toxicity associated with SBRT.

  6. Induction of simultaneous and sequential malolactic fermentation in durian wine.

    Science.gov (United States)

    Taniasuri, Fransisca; Lee, Pin-Rou; Liu, Shao-Quan

    2016-08-02

    This study represented for the first time the impact of malolactic fermentation (MLF) induced by Oenococcus oeni and its inoculation strategies (simultaneous vs. sequential) on the fermentation performance as well as aroma compound profile of durian wine. There was no negative impact of simultaneous inoculation of O. oeni and Saccharomyces cerevisiae on the growth and fermentation kinetics of S. cerevisiae as compared to sequential fermentation. Simultaneous MLF did not lead to an excessive increase in volatile acidity as compared to sequential MLF. The kinetic changes of organic acids (i.e. malic, lactic, succinic, acetic and α-ketoglutaric acids) varied with simultaneous and sequential MLF relative to yeast alone. MLF, regardless of inoculation mode, resulted in higher production of fermentation-derived volatiles as compared to control (alcoholic fermentation only), including esters, volatile fatty acids, and terpenes, except for higher alcohols. Most indigenous volatile sulphur compounds in durian were decreased to trace levels with little differences among the control, simultaneous and sequential MLF. Among the different wines, the wine with simultaneous MLF had higher concentrations of terpenes and acetate esters while sequential MLF had increased concentrations of medium- and long-chain ethyl esters. Relative to alcoholic fermentation only, both simultaneous and sequential MLF reduced acetaldehyde substantially with sequential MLF being more effective. These findings illustrate that MLF is an effective and novel way of modulating the volatile and aroma compound profile of durian wine. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Sequential Banking.

    OpenAIRE

    Bizer, David S; DeMarzo, Peter M

    1992-01-01

    The authors study environments in which agents may borrow sequentially from more than one leader. Although debt is prioritized, additional lending imposes an externality on prior debt because, with moral hazard, the probability of repayment of prior loans decreases. Equilibrium interest rates are higher than they would be if borrowers could commit to borrow from at most one bank. Even though the loan terms are less favorable than they would be under commitment, the indebtedness of borrowers i...

  8. Equivalence between quantum simultaneous games and quantum sequential games

    OpenAIRE

    Kobayashi, Naoki

    2007-01-01

    A framework for discussing relationships between different types of games is proposed. Within the framework, quantum simultaneous games, finite quantum simultaneous games, quantum sequential games, and finite quantum sequential games are defined. In addition, a notion of equivalence between two games is defined. Finally, the following three theorems are shown: (1) For any quantum simultaneous game G, there exists a quantum sequential game equivalent to G. (2) For any finite quantum simultaneo...

  9. Quality assurance procedure for an industrial radiography linear accelerator

    International Nuclear Information System (INIS)

    Vishwakarma, R.R.; Kannan, R.; Yadav, R.K.

    2001-01-01

    Any radiation generating equipment can be marketed and used in India, only after obtaining specific type approval from the Competent Authority i.e. Chairman, Atomic Energy Regulatory Board (AERB). Generally linear accelerators are allowed to be used in the country based on the type approval issued by the regulatory authority of the country of its origin. So type approval of imported linear accelerators do not involve many parameters to be tested in our country. However for an indigenous accelerator, test procedures are to be defined and the same are to be followed during type approval process. No such protocol is available for linear accelerators used in industrial radiography. Recently some Indian manufacturers have started manufacturing and supplying such accelerators. A need for developing an indigenous protocol for type approval/NOC of such accelerators has arisen and the same has been developed. Various requirements for such protocol are discussed in this paper. Measurements have been performed on one of the 4 MV indigenous unit. Results of such measurements are also presented. Need for a regular periodic quality assurance program is necessary for imported as well as indigenous accelerators. A program for such quality assurance is also listed in the paper. (author)

  10. Accounting for Heterogeneous Returns in Sequential Schooling Decisions

    NARCIS (Netherlands)

    Zamarro, G.

    2006-01-01

    This paper presents a method for estimating returns to schooling that takes into account that returns may be heterogeneous among agents and that educational decisions are made sequentially.A sequential decision model is interesting because it explicitly considers that the level of education of each

  11. Transaction costs and sequential bargaining in transferable discharge permit markets.

    Science.gov (United States)

    Netusil, N R; Braden, J B

    2001-03-01

    Market-type mechanisms have been introduced and are being explored for various environmental programs. Several existing programs, however, have not attained the cost savings that were initially projected. Modeling that acknowledges the role of transactions costs and the discrete, bilateral, and sequential manner in which trades are executed should provide a more realistic basis for calculating potential cost savings. This paper presents empirical evidence on potential cost savings by examining a market for the abatement of sediment from farmland. Empirical results based on a market simulation model find no statistically significant change in mean abatement costs under several transaction cost levels when contracts are randomly executed. An alternative method of contract execution, gain-ranked, yields similar results. At the highest transaction cost level studied, trading reduces the total cost of compliance relative to a uniform standard that reflects current regulations.

  12. Accelerator mass spectrometry researches at NIES-TERRA

    International Nuclear Information System (INIS)

    Shibata, Yasuyuki; Yoneda, Minoru; Tanaka, Atsushi; Uehiro, Takashi; Morita, Masatoshi; Uchida, Masao; Yoshinaga, Jun

    2003-01-01

    In the AMS facility at the National Institute for Environmental Studies (NIES-TERRA; Tandem accelerator for Environmental Research and Radiocarbon Analysis), several research programs have been proceeded, including a program, called GC-AMS, for the compound-specific 14 C analysis in environmental samples

  13. Simultaneous Versus Sequential Ptosis and Strabismus Surgery in Children.

    Science.gov (United States)

    Revere, Karen E; Binenbaum, Gil; Li, Jonathan; Mills, Monte D; Katowitz, William R; Katowitz, James A

    The authors sought to compare the clinical outcomes of simultaneous versus sequential ptosis and strabismus surgery in children. Retrospective, single-center cohort study of children requiring both ptosis and strabismus surgery on the same eye. Simultaneous surgeries were performed during a single anesthetic event; sequential surgeries were performed at least 7 weeks apart. Outcomes were ptosis surgery success (margin reflex distance 1 ≥ 2 mm, good eyelid contour, and good eyelid crease); strabismus surgery success (ocular alignment within 10 prism diopters of orthophoria and/or improved head position); surgical complications; and reoperations. Fifty-six children were studied, 38 had simultaneous surgery and 18 sequential. Strabismus surgery was performed first in 38/38 simultaneous and 6/18 sequential cases. Mean age at first surgery was 64 months, with mean follow up 27 months. A total of 75% of children had congenital ptosis; 64% had comitant strabismus. A majority of ptosis surgeries were frontalis sling (59%) or Fasanella-Servat (30%) procedures. There were no significant differences between simultaneous and sequential groups with regards to surgical success rates, complications, or reoperations (all p > 0.28). In the first comparative study of simultaneous versus sequential ptosis and strabismus surgery, no advantage for sequential surgery was seen. Despite a theoretical risk of postoperative eyelid malposition or complications when surgeries were performed in a combined manner, the rate of such outcomes was not increased with simultaneous surgeries. Performing ptosis and strabismus surgery together appears to be clinically effective and safe, and reduces anesthesia exposure during childhood.

  14. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis

    In this thesis we describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon codes with non-uniform profile. With this scheme decoding with good performance...... is possible as low as Eb/No=0.6 dB, which is about 1.7 dB below the signal-to-noise ratio that marks the cut-off rate for the convolutional code. This is possible since the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability...... of computational overflow. Analytical results for the probability that the first Reed-Solomon word is decoded after C computations are presented. This is supported by simulation results that are also extended to other parameters....

  15. Potential advantages and disadvantages of sequentially building small nuclear units instead of a large nuclear plant

    International Nuclear Information System (INIS)

    Feretic, D.; Cavlina, N.; Grgic, D.

    2008-01-01

    Renewal of nuclear power programs in countries with modest electricity consumptions and weak electrical grid interconnections has raised the question of optimal nuclear power plants sizes for such countries. The same question would be also valid for isolated or weakly connected regions within a large country. Building large size nuclear power plant could be prevented by technical or financial limits. Research programs have been initiated in the International Atomic Energy Agency and in the USA (within the framework of the Global Nuclear Energy Partnership (GNEP) program) with the aim to inspect under which circumstances small and medium reactors could be the preferred option compared to large nuclear plants. The economy of scale is a clear advantage of large plants. This paper compares, by using probabilistic methods, the net cash flow of large and medium size plants, taking as example a large nuclear plant (around 1200 MW) and four sequentially built smaller plants (300 MW). Potential advantages and disadvantageous of both options have been considered. Main advantages of the sequential construction of several identical small units could be the reduced investor risk and reduced investment costs due to the learning effect. This analysis is a part of studies for the Croatian power generating system development. (orig.)

  16. Reading Remediation Based on Sequential and Simultaneous Processing.

    Science.gov (United States)

    Gunnison, Judy; And Others

    1982-01-01

    The theory postulating a dichotomy between sequential and simultaneous processing is reviewed and its implications for remediating reading problems are reviewed. Research is cited on sequential-simultaneous processing for early and advanced reading. A list of remedial strategies based on the processing dichotomy addresses decoding and lexical…

  17. Real-time skin feature identification in a time-sequential video stream

    Science.gov (United States)

    Kramberger, Iztok

    2005-04-01

    Skin color can be an important feature when tracking skin-colored objects. Particularly this is the case for computer-vision-based human-computer interfaces (HCI). Humans have a highly developed feeling of space and, therefore, it is reasonable to support this within intelligent HCI, where the importance of augmented reality can be foreseen. Joining human-like interaction techniques within multimodal HCI could, or will, gain a feature for modern mobile telecommunication devices. On the other hand, real-time processing plays an important role in achieving more natural and physically intuitive ways of human-machine interaction. The main scope of this work is the development of a stereoscopic computer-vision hardware-accelerated framework for real-time skin feature identification in the sense of a single-pass image segmentation process. The hardware-accelerated preprocessing stage is presented with the purpose of color and spatial filtering, where the skin color model within the hue-saturation-value (HSV) color space is given with a polyhedron of threshold values representing the basis of the filter model. An adaptive filter management unit is suggested to achieve better segmentation results. This enables the adoption of filter parameters to the current scene conditions in an adaptive way. Implementation of the suggested hardware structure is given at the level of filed programmable system level integrated circuit (FPSLIC) devices using an embedded microcontroller as their main feature. A stereoscopic clue is achieved using a time-sequential video stream, but this shows no difference for real-time processing requirements in terms of hardware complexity. The experimental results for the hardware-accelerated preprocessing stage are given by efficiency estimation of the presented hardware structure using a simple motion-detection algorithm based on a binary function.

  18. Accelerator Based Neutron Beams for Neutron Capture Therapy

    International Nuclear Information System (INIS)

    Yanch, Jacquelyn C.

    2003-01-01

    The DOE-funded accelerator BNCT program at the Massachusetts Institute of Technology has resulted in the only operating accelerator-based epithermal neutron beam facility capable of generating significant dose rates in the world. With five separate beamlines and two different epithermal neutron beam assemblies installed, we are currently capable of treating patients with rheumatoid arthritis in less than 15 minutes (knee joints) or 4 minutes (finger joints) or irradiating patients with shallow brain tumors to a healthy tissue dose of 12.6 Gy in 3.6 hours. The accelerator, designed by Newton scientific Incorporated, is located in dedicated laboratory space that MIT renovated specifically for this project. The Laboratory for Accelerator Beam Applications consists of an accelerator room, a control room, a shielded radiation vault, and additional laboratory space nearby. In addition to the design, construction and characterization of the tandem electrostatic accelerator, this program also resulted in other significant accomplishments. Assemblies for generating epithermal neutron beams were designed, constructed and experimentally evaluated using mixed-field dosimetry techniques. Strategies for target construction and target cooling were implemented and tested. We demonstrated that the method of submerged jet impingement using water as the coolant is capable of handling power densities of up to 6 x 10(sup 7) W/m(sup 2) with heat transfer coefficients of 10(sup 6)W/m(sup 2)-K. Experiments with the liquid metal gallium demonstrated its superiority compared with water with little effect on the neutronic properties of the epithermal beam. Monoenergetic proton beams generated using the accelerator were used to evaluate proton RBE as a function of LET and demonstrated a maximum RBE at approximately 30-40 keV/um, a finding consistent with results published by other researchers. We also developed an experimental approach to biological intercomparison of epithermal beams and

  19. Preliminary tests of the electrostatic plasma accelerator

    Science.gov (United States)

    Aston, G.; Acker, T.

    1990-01-01

    This report describes the results of a program to verify an electrostatic plasma acceleration concept and to identify those parameters most important in optimizing an Electrostatic Plasma Accelerator (EPA) thruster based upon this thrust mechanism. Preliminary performance measurements of thrust, specific impulse and efficiency were obtained using a unique plasma exhaust momentum probe. Reliable EPA thruster operation was achieved using one power supply.

  20. Accelerator Technology Program: Status report, October 1985--March 1986: Volume 1

    International Nuclear Information System (INIS)

    Jameson, R.A.; Schriber, S.O.

    1988-07-01

    This report presents highlights of the major projects in the Accelerator Technology (AT) Division of the Los Alamos National Laboratory. The first section details progress associated with the accelerator test stand. Following sections cover achievements in accelerator theory and simulation, LAMPF II accomplishments, and updates on BEAR, beam dynamics, the rf laboratory, p-bar gravity experiment, University of Illinois racetrack microtron, and NBS microtron. Also included are results from the Proton Storage Ring commissioning, developments in very high microwave systems, and advances in the Fusion Materials Irradiation Test rf technology. In addition, the Phoenix Project and the Krypton Fluoride Project are discussed. The report concludes with a listing of papers published by AT-Division personnel during this reporting period. 42 figs., 5 tabs

  1. Is the brain's inertia for motor movements different for acceleration and deceleration?

    Directory of Open Access Journals (Sweden)

    Bhim M Adhikari

    Full Text Available The brain's ability to synchronize movements with external cues is used daily, yet neuroscience is far from a full understanding of the brain mechanisms that facilitate and set behavioral limits on these sequential performances. This functional magnetic resonance imaging (fMRI study was designed to help understand the neural basis of behavioral performance differences on a synchronizing movement task during increasing (acceleration and decreasing (deceleration metronome rates. In the MRI scanner, subjects were instructed to tap their right index finger on a response box in synchrony to visual cues presented on a display screen. The tapping rate varied either continuously or in discrete steps ranging from 0.5 Hz to 3 Hz. Subjects were able to synchronize better during continuously accelerating rhythms than in continuously or discretely decelerating rhythms. The fMRI data revealed that the precuneus was activated more during continuous deceleration than during acceleration with the hysteresis effect significant at rhythm rates above 1 Hz. From the behavioral data, two performance measures, tapping rate and synchrony index, were derived to further analyze the relative brain activity during acceleration and deceleration of rhythms. Tapping rate was associated with a greater brain activity during deceleration in the cerebellum, superior temporal gyrus and parahippocampal gyrus. Synchrony index was associated with a greater activity during the continuous acceleration phase than during the continuous deceleration or discrete acceleration phases in a distributed network of regions including the prefrontal cortex and precuneus. These results indicate that the brain's inertia for movement is different for acceleration and deceleration, which may have implications in understanding the origin of our perceptual and behavioral limits.

  2. Electrostatic field distributions in the Harwell Tandem accelerator

    International Nuclear Information System (INIS)

    Read, P.M.

    1981-11-01

    The electrostatic field distributions in the Harwell Tandem accelerator have been precisely calculated using the electrostatics program FINALE. The results indicate that the accelerator which presently has an upper voltage limit of 6.5 MV has the potential to operate at 8 MV. Such an upgrade could be achieved by a modification to the high voltage terminal. Replacement of the existing accelerator tubes with accelerator tubes capable of a gradient of 1.8 MV/m would also be required. The existing stack may also require replacement. The terminal modification itself would reduce the terminal to tank breakdown frequency. (author)

  3. CO2 laser technology for advanced particle accelerators

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.

    1996-06-01

    Short-pulse, high-power CO 2 lasers open new prospects for development of ultra-high gradient laser-driven electron accelerators. The advantages of λ=10 μm CO 2 laser radiation over the more widely exploited solid state lasers with λ∼1 μm are based on a λ 2 -proportional ponderomotive potential, λ-proportional phase slippage, and λ-proportional scaling of the laser accelerator structures. We show how a picosecond terawatt CO 2 laser that is under construction at the Brookhaven Accelerator Test Facility may benefit the ATF's experimental program of testing far-field, near-field, and plasma accelerator schemes

  4. Short-Range Temporal Interactions in Sleep; Hippocampal Spike Avalanches Support a Large Milieu of Sequential Activity Including Replay.

    Directory of Open Access Journals (Sweden)

    J Matthew Mahoney

    Full Text Available Hippocampal neural systems consolidate multiple complex behaviors into memory. However, the temporal structure of neural firing supporting complex memory consolidation is unknown. Replay of hippocampal place cells during sleep supports the view that a simple repetitive behavior modifies sleep firing dynamics, but does not explain how multiple episodes could be integrated into associative networks for recollection during future cognition. Here we decode sequential firing structure within spike avalanches of all pyramidal cells recorded in sleeping rats after running in a circular track. We find that short sequences that combine into multiple long sequences capture the majority of the sequential structure during sleep, including replay of hippocampal place cells. The ensemble, however, is not optimized for maximally producing the behavior-enriched episode. Thus behavioral programming of sequential correlations occurs at the level of short-range interactions, not whole behavioral sequences and these short sequences are assembled into a large and complex milieu that could support complex memory consolidation.

  5. Computer codes for particle accelerator design and analysis: A compendium. Second edition

    International Nuclear Information System (INIS)

    Deaven, H.S.; Chan, K.C.D.

    1990-05-01

    The design of the next generation of high-energy accelerators will probably be done as an international collaborative efforts and it would make sense to establish, either formally or informally, an international center for accelerator codes with branches for maintenance, distribution, and consultation at strategically located accelerator centers around the world. This arrangement could have at least three beneficial effects. It would cut down duplication of effort, provide long-term support for the best codes, and provide a stimulating atmosphere for the evolution of new codes. It does not take much foresight to see that the natural evolution of accelerator design codes is toward the development of so-called Expert Systems, systems capable of taking design specifications of future accelerators and producing specifications for optimized magnetic transport and acceleration components, making a layout, and giving a fairly impartial cost estimate. Such an expert program would use present-day programs such as TRANSPORT, POISSON, and SUPERFISH as tools in the optimization process. Such a program would also serve to codify the experience of two generations of accelerator designers before it is lost as these designers reach retirement age. This document describes 203 codes that originate from 10 countries and are currently in use. The authors feel that this compendium will contribute to the dialogue supporting the international collaborative effort that is taking place in the field of accelerator physics today

  6. Automatic performance tuning of parallel and accelerated seismic imaging kernels

    KAUST Repository

    Haberdar, Hakan; Siddiqui, Shahzeb; Feki, Saber

    2014-01-01

    the performance of the MPI communications as well as developer productivity by providing a higher level of abstraction. Keeping productivity in mind, we opted toward pragma based programming for accelerated computation on latest accelerated architectures

  7. The Light Ion Biomedical Research Accelerator (LIBRA)

    International Nuclear Information System (INIS)

    Gough, R.A.

    1987-03-01

    LIBRA is a concept to place a light-ion, charged-particle facility in a hospital environment, and to dedicate it to applications in biology and medicine. There are two aspects of the program envisaged for LIBRA: a basic research effort coupled with a program in clinical applications of accelerated charged particles. The operational environment to be provided for LIBRA is one in which both of these components can coexist and flourish, and one that will promote the transfer of technology and knowledge from one to the other. In order to further investigate the prospects for a Light Ion Biomedical Research Accelerator (LIBRA), discussions are underway with the Merritt Peralta Medical Center (MPMC) in Oakland, California, and the University of California at San Francisco (UCSF). In this paper, a brief discussion of the technical requirements for such a facility is given, together with an outline of the accelerator technology required. While still in a preliminary stage, it is possible nevertheless to develop an adequate working description of the type, size, performance and cost of the accelerator facilities required to meet the preliminary goals for LIBRA

  8. Programming in Fortran M

    Energy Technology Data Exchange (ETDEWEB)

    Foster, I.; Olson, R.; Tuecke, S.

    1993-08-01

    Fortran M is a small set of extensions to Fortran that supports a modular approach to the construction of sequential and parallel programs. Fortran M programs use channels to plug together processes which may be written in Fortran M or Fortran 77. Processes communicate by sending and receiving messages on channels. Channels and processes can be created dynamically, but programs remain deterministic unless specialized nondeterministic constructs are used. Fortran M programs can execute on a range of sequential, parallel, and networked computers. This report incorporates both a tutorial introduction to Fortran M and a users guide for the Fortran M compiler developed at Argonne National Laboratory. The Fortran M compiler, supporting software, and documentation are made available free of charge by Argonne National Laboratory, but are protected by a copyright which places certain restrictions on how they may be redistributed. See the software for details. The latest version of both the compiler and this manual can be obtained by anonymous ftp from Argonne National Laboratory in the directory pub/fortran-m at info.mcs.anl.gov.

  9. Top-down attention affects sequential regularity representation in the human visual system.

    Science.gov (United States)

    Kimura, Motohiro; Widmann, Andreas; Schröger, Erich

    2010-08-01

    Recent neuroscience studies using visual mismatch negativity (visual MMN), an event-related brain potential (ERP) index of memory-mismatch processes in the visual sensory system, have shown that although sequential regularities embedded in successive visual stimuli can be automatically represented in the visual sensory system, an existence of sequential regularity itself does not guarantee that the sequential regularity will be automatically represented. In the present study, we investigated the effects of top-down attention on sequential regularity representation in the visual sensory system. Our results showed that a sequential regularity (SSSSD) embedded in a modified oddball sequence where infrequent deviant (D) and frequent standard stimuli (S) differing in luminance were regularly presented (SSSSDSSSSDSSSSD...) was represented in the visual sensory system only when participants attended the sequential regularity in luminance, but not when participants ignored the stimuli or simply attended the dimension of luminance per se. This suggests that top-down attention affects sequential regularity representation in the visual sensory system and that top-down attention is a prerequisite for particular sequential regularities to be represented. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Limitations of heavy ion synchrotron acceleration for inertial fusion

    International Nuclear Information System (INIS)

    Berley, D.; Danby, G.T.

    1977-01-01

    The potential benefits from heavy ion inertial fusion motivate the rapid development of a program to test the principle. To define the program, accelerator parameters which have not hitherto been commonly considered must be studied interactively with basic questions of space charge limitations and charge exchange. Beam lifetime and power output efficiency may ultimately lead to a linear accelerator as the choice for an ignition device. For proof of principle, however, at power levels way beyond present inertial fusion experience, synchrotrons may have applicability at lower cost. The power and energy which can be delivered by the accelerating system to the reaction chamber are limited by space charge defocussing and intra beam charge exchange scattering, both of which are beam density dependent. These put constraints on linac injector energy, synchrotron aperture, synchrotron magnetic rigidity, acceleration time, ion species and charge to mass ratio. The accelerator system considered is classical. A linear accelerator injects into a synchrotron which accelerates the ion beam to the full energy delivered to the target. The maximum energy deliverable by a synchrotron is treated in section I. The targetting parameters and the energy gained through synchrotron acceleration completely determine the synchrotron aperture. These are discussed in sections II and III. The ion range in material is treated in section IV. The problem of intrabeam scattering is considered in section V. Finally, in section VI is a discussion of examples to meet specified goals

  11. RAMI analysis and modeling for the LANSCE accelerator systems

    Energy Technology Data Exchange (ETDEWEB)

    Macek, R.J.; Wilkinson, C.A. [Los Alamos National Laboratory, NM (United States)

    1995-10-01

    Reliability, availability, maintainability, and inspectability (RAMI) have become important issues for the high-power machines being planned for applications such as accelerator transmutation of nuclear waste (ATW), accelerator production of tritium (APT) and the next generation spallation neutron source. Beam reliability and beam availability are vitally important specifications to the present users of accelerator-driven spallation neutron sources, synchrotron light sources and medical accelerators. At Los Alamos, improved beam availability is a key goal in the planned LANSCE improvement program. Clearly, the capability to adequately model and predict the reliability and availability of complex accelerator systems will be of great value in assessing and optimizing RAMI measures in accelerator design and improvement programs. To date, no major accelerator project has developed comprehensive reliability models although the Advance Photon Source at ANL has started work on reliability analysis for selected subsystems. In this paper the authors discuss their experience in developing RAMI analysis and modeling for the LANSCE Accelerator Systems. Progress has been made in developing suitable measures and functions to characterize user risk, in logging of needed data on failure rates and repair/down times, and in developing a first-pass RAMI model for selected subsystems. Plans have been made for a more complete RAMI model. In addition, the authors discuss their experience in the use of probabilistic risk assessment (PRA) methodology for estimation of the reliability of active, instrumentation-based, radiation safety systems at LANSCE.

  12. Teaching and Research with Accelerators at Tarleton State University

    International Nuclear Information System (INIS)

    Marble, Daniel K.

    2009-01-01

    Tarleton State University students began performing both research and laboratory experiments using accelerators in 1998 through visitation programs at the University of North Texas, US Army Research Laboratory, and the Naval Surface Warfare Center at Carderock. In 2003, Tarleton outfitted its new science building with a 1 MV pelletron that was donated by the California Institution of Technology. The accelerator has been upgraded and supports a wide range of classes for both the Physics program and the ABET accredited Engineering Physics program as well as supplying undergraduate research opportunities on campus. A discussion of various laboratory activities and research projects performed by Tarleton students will be presented.

  13. Mining compressing sequential problems

    NARCIS (Netherlands)

    Hoang, T.L.; Mörchen, F.; Fradkin, D.; Calders, T.G.K.

    2012-01-01

    Compression based pattern mining has been successfully applied to many data mining tasks. We propose an approach based on the minimum description length principle to extract sequential patterns that compress a database of sequences well. We show that mining compressing patterns is NP-Hard and

  14. Fast sequential Monte Carlo methods for counting and optimization

    CERN Document Server

    Rubinstein, Reuven Y; Vaisman, Radislav

    2013-01-01

    A comprehensive account of the theory and application of Monte Carlo methods Based on years of research in efficient Monte Carlo methods for estimation of rare-event probabilities, counting problems, and combinatorial optimization, Fast Sequential Monte Carlo Methods for Counting and Optimization is a complete illustration of fast sequential Monte Carlo techniques. The book provides an accessible overview of current work in the field of Monte Carlo methods, specifically sequential Monte Carlo techniques, for solving abstract counting and optimization problems. Written by authorities in the

  15. New accelerators. Why do we need them?

    International Nuclear Information System (INIS)

    Haeusser, O.

    1989-12-01

    The impressive success of the Standard Model of quarks and leptons and their unified interactions has stimulated new and important questions for both nuclear and particle physics. These questions have motivated the planning and construction of several large new accelerator facilities with complementary science programs. We touch here on some of the physics goals that will be pursued with the new breed of accelerators

  16. New accelerators: why do we need them

    International Nuclear Information System (INIS)

    Haeusser, O.

    1989-01-01

    The impressive success of the Standard Model of quarks and leptons and their unified interactions has stimulated new and important questions for both nuclear and particle physics. These questions have motivated the planning and construction of several large new accelerator facilities with complementary science programs. We touch here on some of the physics goals that will be pursued with the new breed of accelerators

  17. An Accelerator control middle layer using Matlab

    CERN Document Server

    Portmann, G J; Terebilo, Andrei

    2005-01-01

    Matlab is a matrix manipulation language originally developed to be a convenient language for using the LINPACK and EISPACK libraries. What makes Matlab so appealing for accelerator physics is the combination of a matrix oriented programming language, an active workspace for system variables, powerful graphics capability, built-in math libraries, and platform independence. A number of software toolboxes for accelerators have been written in Matlab – the Accelerator Toolbox (AT) for machine simulations, LOCO for accelerator calibration, Matlab Channel Access Toolbox (MCA) for EPICS connections, and the Middle Layer. This paper will describe the MiddleLayer software toolbox that resides between the high-level control applications and the low-level accelerator control system. This software was a collaborative effort between ALS and Spear but was written to easily port. Five accelerators presently use this software – Spear, ALS, CLS, and the X-ray and VUV rings at Brookhaven. The Middle Layer fu...

  18. Automatic generation of application specific FPGA multicore accelerators

    DEFF Research Database (Denmark)

    Hindborg, Andreas Erik; Schleuniger, Pascal; Jensen, Nicklas Bo

    2014-01-01

    High performance computing systems make increasing use of hardware accelerators to improve performance and power properties. For large high-performance FPGAs to be successfully integrated in such computing systems, methods to raise the abstraction level of FPGA programming are required...... to identify optimal performance energy trade-offs points for a multicore based FPGA accelerator....

  19. A sequential vesicle pool model with a single release sensor and a ca(2+)-dependent priming catalyst effectively explains ca(2+)-dependent properties of neurosecretion

    DEFF Research Database (Denmark)

    Walter, Alexander M; da Silva Pinheiro, Paulo César; Verhage, Matthijs

    2013-01-01

    identified. We here propose a Sequential Pool Model (SPM), assuming a novel Ca(2+)-dependent action: a Ca(2+)-dependent catalyst that accelerates both forward and reverse priming reactions. While both models account for fast fusion from the Readily-Releasable Pool (RRP) under control of synaptotagmin-1...... the simultaneous changes in release rate and amplitude seen when mutating the SNARE-complex. Finally, it can account for the loss of fast- and the persistence of slow release in the synaptotagmin-1 knockout by assuming that the RRP is depleted, leading to slow and Ca(2+)-dependent fusion from the NRP. We conclude...... that the elusive 'alternative Ca(2+) sensor' for slow release might be the upstream priming catalyst, and that a sequential model effectively explains Ca(2+)-dependent properties of secretion without assuming parallel pools or sensors....

  20. GPU-accelerated 3D neutron diffusion code based on finite difference method

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Q.; Yu, G.; Wang, K. [Dept. of Engineering Physics, Tsinghua Univ. (China)

    2012-07-01

    Finite difference method, as a traditional numerical solution to neutron diffusion equation, although considered simpler and more precise than the coarse mesh nodal methods, has a bottle neck to be widely applied caused by the huge memory and unendurable computation time it requires. In recent years, the concept of General-Purpose computation on GPUs has provided us with a powerful computational engine for scientific research. In this study, a GPU-Accelerated multi-group 3D neutron diffusion code based on finite difference method was developed. First, a clean-sheet neutron diffusion code (3DFD-CPU) was written in C++ on the CPU architecture, and later ported to GPUs under NVIDIA's CUDA platform (3DFD-GPU). The IAEA 3D PWR benchmark problem was calculated in the numerical test, where three different codes, including the original CPU-based sequential code, the HYPRE (High Performance Pre-conditioners)-based diffusion code and CITATION, were used as counterpoints to test the efficiency and accuracy of the GPU-based program. The results demonstrate both high efficiency and adequate accuracy of the GPU implementation for neutron diffusion equation. A speedup factor of about 46 times was obtained, using NVIDIA's Geforce GTX470 GPU card against a 2.50 GHz Intel Quad Q9300 CPU processor. Compared with the HYPRE-based code performing in parallel on an 8-core tower server, the speedup of about 2 still could be observed. More encouragingly, without any mathematical acceleration technology, the GPU implementation ran about 5 times faster than CITATION which was speeded up by using the SOR method and Chebyshev extrapolation technique. (authors)

  1. GPU-accelerated 3D neutron diffusion code based on finite difference method

    International Nuclear Information System (INIS)

    Xu, Q.; Yu, G.; Wang, K.

    2012-01-01

    Finite difference method, as a traditional numerical solution to neutron diffusion equation, although considered simpler and more precise than the coarse mesh nodal methods, has a bottle neck to be widely applied caused by the huge memory and unendurable computation time it requires. In recent years, the concept of General-Purpose computation on GPUs has provided us with a powerful computational engine for scientific research. In this study, a GPU-Accelerated multi-group 3D neutron diffusion code based on finite difference method was developed. First, a clean-sheet neutron diffusion code (3DFD-CPU) was written in C++ on the CPU architecture, and later ported to GPUs under NVIDIA's CUDA platform (3DFD-GPU). The IAEA 3D PWR benchmark problem was calculated in the numerical test, where three different codes, including the original CPU-based sequential code, the HYPRE (High Performance Pre-conditioners)-based diffusion code and CITATION, were used as counterpoints to test the efficiency and accuracy of the GPU-based program. The results demonstrate both high efficiency and adequate accuracy of the GPU implementation for neutron diffusion equation. A speedup factor of about 46 times was obtained, using NVIDIA's Geforce GTX470 GPU card against a 2.50 GHz Intel Quad Q9300 CPU processor. Compared with the HYPRE-based code performing in parallel on an 8-core tower server, the speedup of about 2 still could be observed. More encouragingly, without any mathematical acceleration technology, the GPU implementation ran about 5 times faster than CITATION which was speeded up by using the SOR method and Chebyshev extrapolation technique. (authors)

  2. Sensitivity Analysis in Sequential Decision Models.

    Science.gov (United States)

    Chen, Qiushi; Ayer, Turgay; Chhatwal, Jagpreet

    2017-02-01

    Sequential decision problems are frequently encountered in medical decision making, which are commonly solved using Markov decision processes (MDPs). Modeling guidelines recommend conducting sensitivity analyses in decision-analytic models to assess the robustness of the model results against the uncertainty in model parameters. However, standard methods of conducting sensitivity analyses cannot be directly applied to sequential decision problems because this would require evaluating all possible decision sequences, typically in the order of trillions, which is not practically feasible. As a result, most MDP-based modeling studies do not examine confidence in their recommended policies. In this study, we provide an approach to estimate uncertainty and confidence in the results of sequential decision models. First, we provide a probabilistic univariate method to identify the most sensitive parameters in MDPs. Second, we present a probabilistic multivariate approach to estimate the overall confidence in the recommended optimal policy considering joint uncertainty in the model parameters. We provide a graphical representation, which we call a policy acceptability curve, to summarize the confidence in the optimal policy by incorporating stakeholders' willingness to accept the base case policy. For a cost-effectiveness analysis, we provide an approach to construct a cost-effectiveness acceptability frontier, which shows the most cost-effective policy as well as the confidence in that for a given willingness to pay threshold. We demonstrate our approach using a simple MDP case study. We developed a method to conduct sensitivity analysis in sequential decision models, which could increase the credibility of these models among stakeholders.

  3. The sequential structure of brain activation predicts skill.

    Science.gov (United States)

    Anderson, John R; Bothell, Daniel; Fincham, Jon M; Moon, Jungaa

    2016-01-29

    In an fMRI study, participants were trained to play a complex video game. They were scanned early and then again after substantial practice. While better players showed greater activation in one region (right dorsal striatum) their relative skill was better diagnosed by considering the sequential structure of whole brain activation. Using a cognitive model that played this game, we extracted a characterization of the mental states that are involved in playing a game and the statistical structure of the transitions among these states. There was a strong correspondence between this measure of sequential structure and the skill of different players. Using multi-voxel pattern analysis, it was possible to recognize, with relatively high accuracy, the cognitive states participants were in during particular scans. We used the sequential structure of these activation-recognized states to predict the skill of individual players. These findings indicate that important features about information-processing strategies can be identified from a model-based analysis of the sequential structure of brain activation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. The design of the MAD Design Program

    International Nuclear Information System (INIS)

    Niederer, J.

    1992-01-01

    The study of long term stability in particle accelerators has long been served by a group of widely circulated computer programs. The progress in these programs has mirrored the growth and versatility in accelerator size, complexity, and purpose, as well as evolving technologies in computing software and hardware. A number of large accelerator projects during the last decade were designed with the aid of physics programs either written for, or tailored for the project at hand, each invariably benefiting from contributions of previous workers. This paper outlines the recent history of of expample of an accelerator lattice model tool kit, the Methodical Accelerator Design (MAD) Program, which has tried to knit together this collective wisdom of the accelerator community, The ideas behind the software design of the program itself are traced here; the accelerator physics contents and origins are thoroughly documented elsewhere. These informal notes have a Brookhaven flavor, in part because of early BNL efforts to generalize the ways that technical problems are organized and presented to computers. Some recent BNL applications not covered in the extensive CERN documentation are also included

  5. A one-sided sequential test

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Lux, I. [Hungarian Academy of Sciences, Budapest (Hungary). Atomic Energy Research Inst.

    1996-04-16

    The applicability of the classical sequential probability ratio testing (SPRT) for early failure detection problems is limited by the fact that there is an extra time delay between the occurrence of the failure and its first recognition. Chien and Adams developed a method to minimize this time for the case when the problem can be formulated as testing the mean value of a Gaussian signal. In our paper we propose a procedure that can be applied for both mean and variance testing and that minimizes the time delay. The method is based on a special parametrization of the classical SPRT. The one-sided sequential tests (OSST) can reproduce the results of the Chien-Adams test when applied for mean values. (author).

  6. Programming

    International Nuclear Information System (INIS)

    Jackson, M.A.

    1982-01-01

    The programmer's task is often taken to be the construction of algorithms, expressed in hierarchical structures of procedures: this view underlies the majority of traditional programming languages, such as Fortran. A different view is appropriate to a wide class of problem, perhaps including some problems in High Energy Physics. The programmer's task is regarded as having three main stages: first, an explicit model is constructed of the reality with which the program is concerned; second, this model is elaborated to produce the required program outputs; third, the resulting program is transformed to run efficiently in the execution environment. The first two stages deal in network structures of sequential processes; only the third is concerned with procedure hierarchies. (orig.)

  7. Indian participation in FAIR accelerator facility

    International Nuclear Information System (INIS)

    Sur, Amitava

    2015-01-01

    India is a founder member of the FAIR-GmbH, the upcoming International Accelerator Facility at Darmstadt, Germany. Indian participation at FAIR is being funded jointly by the Department of Science and Technology (DST) and the Department of Atomic Energy (DAE). Indo- FAIR Coordination Centre at Bose Institute (BI-IFCC) is coordinating the Indian efforts of both in-kind contribution as well as experimental programmes at FAIR. FAIR aims for beams of stable and unstable nuclei as well as antiprotons in a wide range of intensities and energies. A superconducting double-synchrotron SIS100/300 with a circumference of 1,100 meters and with magnetic rigidities of 100 and 300 Tm, respectively, is at the heart of the FAIR accelerator facility. The existing GSI accelerators UNILAC and SIS18 will serve as an injector. Adjacent to the large double- synchrotron is a complex system of storage- cooler rings and experiment stations, including a superconducting nuclear fragment separator (Super-FRS) and an antiproton production target. FAIR will supply rare isotope beams (RIBs) and antiproton beams. In FAIR accelerator facility up to four research programs can be run in a parallel mode. The multidisciplinary research program covers the fields of QCD studies with cooled beams of antiprotons, nucleus nucleus collisions at highest baryon density, nuclear structure and nuclear astrophysics investigations with nuclei far off stability, high density plasma physics, atomic and material science studies, radio-biological and other application-oriented studies will contribute in providing in-kind items both for the accelerator and the experiments. As per current plans Indian in kind contributions include: Power Converters, Superconducting Magnets, Beam Stopper, Vacuum Chamber. A short sample from an Indian Industry has been tested successfully at FAIR. Indian participation in building the accelerator components for FAIR is presented

  8. An Analysis of OpenACC Programming Model: Image Processing Algorithms as a Case Study

    Directory of Open Access Journals (Sweden)

    M. J. Mišić

    2014-06-01

    Full Text Available Graphics processing units and similar accelerators have been intensively used in general purpose computations for several years. In the last decade, GPU architecture and organization changed dramatically to support an ever-increasing demand for computing power. Along with changes in hardware, novel programming models have been proposed, such as NVIDIA’s Compute Unified Device Architecture (CUDA and Open Computing Language (OpenCL by Khronos group. Although numerous commercial and scientific applications have been developed using these two models, they still impose a significant challenge for less experienced users. There are users from various scientific and engineering communities who would like to speed up their applications without the need to deeply understand a low-level programming model and underlying hardware. In 2011, OpenACC programming model was launched. Much like OpenMP for multicore processors, OpenACC is a high-level, directive-based programming model for manycore processors like GPUs. This paper presents an analysis of OpenACC programming model and its applicability in typical domains like image processing. Three, simple image processing algorithms have been implemented for execution on the GPU with OpenACC. The results were compared with their sequential counterparts, and results are briefly discussed.

  9. Mining Emerging Sequential Patterns for Activity Recognition in Body Sensor Networks

    DEFF Research Database (Denmark)

    Gu, Tao; Wang, Liang; Chen, Hanhua

    2010-01-01

    Body Sensor Networks oer many applications in healthcare, well-being and entertainment. One of the emerging applications is recognizing activities of daily living. In this paper, we introduce a novel knowledge pattern named Emerging Sequential Pattern (ESP)|a sequential pattern that discovers...... signicant class dierences|to recognize both simple (i.e., sequential) and complex (i.e., interleaved and concurrent) activities. Based on ESPs, we build our complex activity models directly upon the sequential model to recognize both activity types. We conduct comprehensive empirical studies to evaluate...

  10. Discrimination between sequential and simultaneous virtual channels with electrical hearing

    OpenAIRE

    Landsberger, David; Galvin, John J.

    2011-01-01

    In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation mode...

  11. 12th Advanced Accelerator Concept (AAC 2006) Workshop

    International Nuclear Information System (INIS)

    Piot, Philippe

    2006-01-01

    Summary of the 12th Advanced Accelerator Concept (AAC 2006) Workshop help by NIU and ANL on July 10th-15th 2006 in Lake Geneva WI. The proceedings of the workshop have been published as an AIP conference proceedings '12th Advanced Accelerator Concepts Workshop' volume 877. The Twelfth Workshop on Advanced Accelerator Concepts was held at the Grand Geneva Resort in Lake Geneva, Wisconsin, from July 10 to July 15, 2006. The Workshop was sponsored by the High Energy Physics program of the U.S. Department of Energy, and was hosted by the Argonne Wakefield Accelerator Group (AWA) of Argonne National Laboratory and by Northern Illinois University. The workshop is a bi-annual meeting among physicist working on novel charged particle acceleration concept. The name 'advanced accelerator' physics covers long term research and development in beam physics and accelerator technologies. Some of the topics in advanced accelerator R and D are laser acceleration of electrons, wake field acceleration, novel high power rf source, new beam diagnostics, free-electron lasers, generating high brightness electron beams etc. The Advanced Accelerator Concept workshop is the only acknowledged and fully sponsored forum that provides a platform for inter- and cross-disciplinary discussion on various aspects of advanced accelerator and beam physics/technology concepts.

  12. Hybrid Computerized Adaptive Testing: From Group Sequential Design to Fully Sequential Design

    Science.gov (United States)

    Wang, Shiyu; Lin, Haiyan; Chang, Hua-Hua; Douglas, Jeff

    2016-01-01

    Computerized adaptive testing (CAT) and multistage testing (MST) have become two of the most popular modes in large-scale computer-based sequential testing. Though most designs of CAT and MST exhibit strength and weakness in recent large-scale implementations, there is no simple answer to the question of which design is better because different…

  13. Visual short-term memory for sequential arrays.

    Science.gov (United States)

    Kumar, Arjun; Jiang, Yuhong

    2005-04-01

    The capacity of visual short-term memory (VSTM) for a single visual display has been investigated in past research, but VSTM for multiple sequential arrays has been explored only recently. In this study, we investigate the capacity of VSTM across two sequential arrays separated by a variable stimulus onset asynchrony (SOA). VSTM for spatial locations (Experiment 1), colors (Experiments 2-4), orientations (Experiments 3 and 4), and conjunction of color and orientation (Experiment 4) were tested, with the SOA across the two sequential arrays varying from 100 to 1,500 msec. We find that VSTM for the trailing array is much better than VSTM for the leading array, but when averaged across the two arrays VSTM has a constant capacity independent of the SOA. We suggest that multiple displays compete for retention in VSTM and that separating information into two temporally discrete groups does not enhance the overall capacity of VSTM.

  14. A Sequential Optimization Sampling Method for Metamodels with Radial Basis Functions

    Science.gov (United States)

    Pan, Guang; Ye, Pengcheng; Yang, Zhidong

    2014-01-01

    Metamodels have been widely used in engineering design to facilitate analysis and optimization of complex systems that involve computationally expensive simulation programs. The accuracy of metamodels is strongly affected by the sampling methods. In this paper, a new sequential optimization sampling method is proposed. Based on the new sampling method, metamodels can be constructed repeatedly through the addition of sampling points, namely, extrema points of metamodels and minimum points of density function. Afterwards, the more accurate metamodels would be constructed by the procedure above. The validity and effectiveness of proposed sampling method are examined by studying typical numerical examples. PMID:25133206

  15. Funding an accelerated baccalaureate nursing track for non-nursing college graduates: an academic/practice collaboration.

    Science.gov (United States)

    Poirrier, Gail P; Oberleitner, Melinda G

    2011-01-01

    To expand nursing programs to better meet workforce demands, nursing education must offer nontraditional students more educational opportunities that are flexible, streamlined, and low cost. Accelerated programs, particularly programs tailored to attract individuals with degrees in other fields and looking for career changes, are great examples. The cost factors related to a successful accelerated degree program designed for non-nursing college graduates are described. Based on the experiences with a previously implemented accelerated BSN program offered from 1987-1994 at one university, a revised accelerated option model was developed that included ongoing involvement with four community hospitals, shared budget responsibilities, student stipends, and a 3-year work commitment by graduates at a sponsoring hospital. The investment of approximately $1.6 million over 7 years resulted in the education and graduation of 75 new registered nursing professionals to meet the health care needs of the citizens of the community.

  16. Inverse Free Electron Laser accelerator

    International Nuclear Information System (INIS)

    Fisher, A.; Gallardo, J.; van Steenbergen, A.; Sandweiss, J.

    1992-09-01

    The study of the INVERSE FREE ELECTRON LASER, as a potential mode of electron acceleration, is being pursued at Brookhaven National Laboratory. Recent studies have focussed on the development of a low energy, high gradient, multi stage linear accelerator. The elementary ingredients for the IFEL interaction are the 50 MeV Linac e - beam and the 10 11 Watt CO 2 laser beam of BNL's Accelerator Test Facility (ATF), Center for Accelerator Physics (CAP) and a wiggler. The latter element is designed as a fast excitation unit making use of alternating stacks of Vanadium Permendur (VaP) ferromagnetic laminations, periodically interspersed with conductive, nonmagnetic laminations, which act as eddy current induced field reflectors. Wiggler parameters and field distribution data will be presented for a prototype wiggler in a constant period and in a ∼ 1.5 %/cm tapered period configuration. The CO 2 laser beam will be transported through the IFEL interaction region by means of a low loss, dielectric coated, rectangular waveguide. Short waveguide test sections have been constructed and have been tested using a low power cw CO 2 laser. Preliminary results of guide attenuation and mode selectivity will be given, together with a discussion of the optical issues for the IFEL accelerator. The IFEL design is supported by the development and use of 1D and 3D simulation programs. The results of simulation computations, including also wiggler errors, for a single module accelerator and for a multi-module accelerator will be presented

  17. Essay: Robert H. Siemann As Leader of the Advanced Accelerator Research Department

    Energy Technology Data Exchange (ETDEWEB)

    Colby, Eric R.; Hogan, Mark J.; /SLAC

    2011-11-14

    Robert H. Siemann originally conceived of the Advanced Accelerator Research Department (AARD) as an academic, experimental group dedicated to probing the technical limitations of accelerators while providing excellent educational opportunities for young scientists. The early years of the Accelerator Research Department B, as it was then known, were dedicated to a wealth of mostly student-led experiments to examine the promise of advanced accelerator techniques. High-gradient techniques including millimeter-wave rf acceleration, beam-driven plasma acceleration, and direct laser acceleration were pursued, including tests of materials under rf pulsed heating and short-pulse laser radiation, to establish the ultimate limitations on gradient. As the department and program grew, so did the motivation to found an accelerator research center that brought experimentalists together in a test facility environment to conduct a broad range of experiments. The Final Focus Test Beam and later the Next Linear Collider Test Accelerator provided unique experimental facilities for AARD staff and collaborators to carry out advanced accelerator experiments. Throughout the evolution of this dynamic program, Bob maintained a department atmosphere and culture more reminiscent of a university research group than a national laboratory department. His exceptional ability to balance multiple roles as scientist, professor, and administrator enabled the creation and preservation of an environment that fostered technical innovation and scholarship.

  18. Essay: Robert H. Siemann As Leader of the Advanced Accelerator Research Department

    International Nuclear Information System (INIS)

    Colby, Eric R.; Hogan, Mark J.

    2008-01-01

    Robert H. Siemann originally conceived of the Advanced Accelerator Research Department (AARD) as an academic, experimental group dedicated to probing the technical limitations of accelerators while providing excellent educational opportunities for young scientists. The early years of the Accelerator Research Department B, as it was then known, were dedicated to a wealth of mostly student-led experiments to examine the promise of advanced accelerator techniques. High-gradient techniques including millimeter-wave rf acceleration, beam-driven plasma acceleration, and direct laser acceleration were pursued, including tests of materials under rf pulsed heating and short-pulse laser radiation, to establish the ultimate limitations on gradient. As the department and program grew, so did the motivation to found an accelerator research center that brought experimentalists together in a test facility environment to conduct a broad range of experiments. The Final Focus Test Beam and later the Next Linear Collider Test Accelerator provided unique experimental facilities for AARD staff and collaborators to carry out advanced accelerator experiments. Throughout the evolution of this dynamic program, Bob maintained a department atmosphere and culture more reminiscent of a university research group than a national laboratory department. His exceptional ability to balance multiple roles as scientist, professor, and administrator enabled the creation and preservation of an environment that fostered technical innovation and scholarship.

  19. The target-to-foils shift in simultaneous and sequential lineups.

    Science.gov (United States)

    Clark, Steven E; Davey, Sherrie L

    2005-04-01

    A theoretical cornerstone in eyewitness identification research is the proposition that witnesses, in making decisions from standard simultaneous lineups, make relative judgments. The present research considers two sources of support for this proposal. An experiment by G. L. Wells (1993) showed that if the target is removed from a lineup, witnesses shift their responses to pick foils, rather than rejecting the lineups, a result we will term a target-to-foils shift. Additional empirical support is provided by results from sequential lineups which typically show higher accuracy than simultaneous lineups, presumably because of a decrease in the use of relative judgments in making identification decisions. The combination of these two lines of research suggests that the target-to-foils shift should be reduced in sequential lineups relative to simultaneous lineups. Results of two experiments showed an overall advantage for sequential lineups, but also showed a target-to-foils shift equal in size for simultaneous and sequential lineups. Additional analyses indicated that the target-to-foils shift in sequential lineups was moderated in part by an order effect and was produced with (Experiment 2) or without (Experiment 1) a shift in decision criterion. This complex pattern of results suggests that more work is needed to understand the processes which underlie decisions in simultaneous and sequential lineups.

  20. Accelerating RCRA corrective action: The principles of the DOE approach

    International Nuclear Information System (INIS)

    Kimmell, T.A.; Green, D.R.; Ranek, N.L.; Coalgate, J.L.

    1995-01-01

    The US Department of Energy (DOE) is involved in the remediation of environmental contamination at many of its facilities under the Resource Conservation and Recovery Act (RCRA). RCRA's corrective action provisions were established by the Hazardous and Solid Waste Amendments of 1984 (HSWA). In response to the HSWA mandate, EPA established a program for the conduct of RCRA corrective action that was similar to that established under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). In addition, EPA developed and implemented its ''stabilization'' initiative as a means of quickly addressing immediate risks posed by releases until long term solutions can be applied. To improve the efficiency of environmental restoration at its facilities, DOE is developing guidance and training programs on accelerated environmental restoration under RCRA. A RCRA guidance document, entitled ''Accelerating RCRA Corrective Action at DOE Facilities,'' is currently being developed by DOE's Office of Environmental Policy and Assistance. The new guidance document will outline a decision-making process for determining if acceleration is appropriate for individual facilities, for identifying, evaluating, and selecting options for program acceleration, and for implementing selected acceleration options. The document will also discuss management and planning strategies that provide a firm foundation for accelerating RCRA corrective action. These strategies include a number of very basic principles that have proven effective at DOE and other federal facilities, as well as some new approaches. The purpose of this paper is to introduce DOE's new guidance document, discuss the general approach presented in the guidance for accelerating RCRA corrective action, and to emphasize some of the more important principles of effective management and planning

  1. Attrition and success rates of accelerated students in nursing courses: a systematic review.

    Science.gov (United States)

    Doggrell, Sheila Anne; Schaffer, Sally

    2016-01-01

    There is a comprehensive literature on the academic outcomes (attrition and success) of students in traditional/baccalaureate nursing programs, but much less is known about the academic outcomes of students in accelerated nursing programs. The aim of this systematic review is to report on the attrition and success rates (either internal examination or NCLEX-RN) of accelerated students, compared to traditional students. For the systematic review, the databases (Pubmed, Cinahl and PsychINFO) and Google Scholar were searched using the search terms 'accelerated' or 'accreditation for prior learning', 'fast-track' or 'top up' and 'nursing' with 'attrition' or 'retention' or 'withdrawal' or 'success' from 1994 to January 2016. All relevant articles were included, regardless of quality. The findings of 19 studies of attrition rates and/or success rates for accelerated students are reported. For international accelerated students, there were only three studies, which are heterogeneous, and have major limitations. One of three studies has lower attrition rates, and one has shown higher success rates, than traditional students. In contrast, another study has shown high attrition and low success for international accelerated students. For graduate accelerated students, most of the studies are high quality, and showed that they have rates similar or better than traditional students. Thus, five of six studies have shown similar or lower attrition rates. Four of these studies with graduate accelerated students and an additional seven studies of success rates only, have shown similar or better success rates, than traditional students. There are only three studies of non-university graduate accelerated students, and these had weaknesses, but were consistent in reporting higher attrition rates than traditional students. The paucity and weakness of information available makes it unclear as to the attrition and/or success of international accelerated students in nursing programs. The

  2. Development of High-Gradient Dielectric Laser-Driven Particle Accelerator Structures

    Energy Technology Data Exchange (ETDEWEB)

    Byer, Robert L. [Stanford Univ., CA (United States). Edward L. Ginzton Lab.

    2013-11-07

    The thrust of Stanford's program is to conduct research on high-gradient dielectric accelerator structures driven with high repetition-rate, tabletop infrared lasers. The close collaboration between Stanford and SLAC (Stanford Linear Accelerator Center) is critical to the success of this project, because it provides a unique environment where prototype dielectric accelerator structures can be rapidly fabricated and tested with a relativistic electron beam.

  3. Quantum Accelerators for High-performance Computing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Humble, Travis S. [ORNL; Britt, Keith A. [ORNL; Mohiyaddin, Fahd A. [ORNL

    2017-11-01

    We define some of the programming and system-level challenges facing the application of quantum processing to high-performance computing. Alongside barriers to physical integration, prominent differences in the execution of quantum and conventional programs challenges the intersection of these computational models. Following a brief overview of the state of the art, we discuss recent advances in programming and execution models for hybrid quantum-classical computing. We discuss a novel quantum-accelerator framework that uses specialized kernels to offload select workloads while integrating with existing computing infrastructure. We elaborate on the role of the host operating system to manage these unique accelerator resources, the prospects for deploying quantum modules, and the requirements placed on the language hierarchy connecting these different system components. We draw on recent advances in the modeling and simulation of quantum computing systems with the development of architectures for hybrid high-performance computing systems and the realization of software stacks for controlling quantum devices. Finally, we present simulation results that describe the expected system-level behavior of high-performance computing systems composed from compute nodes with quantum processing units. We describe performance for these hybrid systems in terms of time-to-solution, accuracy, and energy consumption, and we use simple application examples to estimate the performance advantage of quantum acceleration.

  4. Dynamics-based sequential memory: Winnerless competition of patterns

    International Nuclear Information System (INIS)

    Seliger, Philip; Tsimring, Lev S.; Rabinovich, Mikhail I.

    2003-01-01

    We introduce a biologically motivated dynamical principle of sequential memory which is based on winnerless competition (WLC) of event images. This mechanism is implemented in a two-layer neural model of sequential spatial memory. We present the learning dynamics which leads to the formation of a WLC network. After learning, the system is capable of associative retrieval of prerecorded sequences of patterns

  5. Sequential, progressive, equal-power, reflective beam-splitter arrays

    Science.gov (United States)

    Manhart, Paul K.

    2017-11-01

    The equations to calculate equal-power reflectivity of a sequential series of beam splitters is presented. Non-sequential optical design examples are offered for uniform illumination using diode lasers. Objects created using Boolean operators and Swept Surfaces can create objects capable of reflecting light into predefined elevation and azimuth angles. Analysis of the illumination patterns for the array are also presented.

  6. Status of control systems for industrial electron accelerators at EBC, Kharghar

    International Nuclear Information System (INIS)

    Jain, Arvind; Kumar, Mukesh; Kaurav, P.S.; Sharma, Vijay; Chawla, A.S.; Sethi, R.C.

    2005-01-01

    The Bhabha Atomic Research Centre (BARC) is setting up two industrial electron accelerators at the Electron Beam Center (EBC) Kharghar. These are a 10 MeV, 10 KW beam power RF linac and a 30 KW, DC, Dynamitron type of machine. The present status of the control systems of these accelerators are presented. Some novel features in the design of the control system include (a) the software and hardware of the control system has been designed such that the same package can be used for the two widely different machines. Thus the control system developed can be used for any new accelerator also by reformatting the built in data base (b) an attempt is being made towards push button operation to minimize the need for machine operators. This is achieved by a sequential start-up and shut down procedure with appropriate time lags built into the software. The PC based centralized control system has been tested and now gives automated operation of the 22 sub-systems of the linac and operating experience of the system for the last one year has been achieved. Similarly, the control system of the 3 MeV DC machine having about 20 subsystems are in the final stage of commissioning and testing. (author)

  7. Dynamic programming models and applications

    CERN Document Server

    Denardo, Eric V

    2003-01-01

    Introduction to sequential decision processes covers use of dynamic programming in studying models of resource allocation, methods for approximating solutions of control problems in continuous time, production control, more. 1982 edition.

  8. Basal ganglia and cortical networks for sequential ordering and rhythm of complex movements

    Directory of Open Access Journals (Sweden)

    Jeffery G. Bednark

    2015-07-01

    Full Text Available Voluntary actions require the concurrent engagement and coordinated control of complex temporal (e.g. rhythm and ordinal motor processes. Using high-resolution functional magnetic resonance imaging (fMRI and multi-voxel pattern analysis (MVPA, we sought to determine the degree to which these complex motor processes are dissociable in basal ganglia and cortical networks. We employed three different finger-tapping tasks that differed in the demand on the sequential temporal rhythm or sequential ordering of submovements. Our results demonstrate that sequential rhythm and sequential order tasks were partially dissociable based on activation differences. The sequential rhythm task activated a widespread network centered around the SMA and basal-ganglia regions including the dorsomedial putamen and caudate nucleus, while the sequential order task preferentially activated a fronto-parietal network. There was also extensive overlap between sequential rhythm and sequential order tasks, with both tasks commonly activating bilateral premotor, supplementary motor, and superior/inferior parietal cortical regions, as well as regions of the caudate/putamen of the basal ganglia and the ventro-lateral thalamus. Importantly, within the cortical regions that were active for both complex movements, MVPA could accurately classify different patterns of activation for the sequential rhythm and sequential order tasks. In the basal ganglia, however, overlapping activation for the sequential rhythm and sequential order tasks, which was found in classic motor circuits of the putamen and ventro-lateral thalamus, could not be accurately differentiated by MVPA. Overall, our results highlight the convergent architecture of the motor system, where complex motor information that is spatially distributed in the cortex converges into a more compact representation in the basal ganglia.

  9. The sequential price of anarchy for atomic congestion games

    NARCIS (Netherlands)

    de Jong, Jasper; Uetz, Marc Jochen; Liu, Tie-Yan; Qi, Qi; Ye, Yinyu

    2014-01-01

    In situations without central coordination, the price of anarchy relates the quality of any Nash equilibrium to the quality of a global optimum. Instead of assuming that all players choose their actions simultaneously, we consider games where players choose their actions sequentially. The sequential

  10. Clearance of materials from accelerator facilities

    Directory of Open Access Journals (Sweden)

    Rokni Sayed H.

    2017-01-01

    Full Text Available A new Technical Standard that supports the clearance of materials and equipment (personal property from U.S. Department of Energy (DOE accelerator facilities has been developed. The Standard focuses on personal property that has the potential to be radiologically impacted by accelerator operations. It addresses material clearance programs and protocols for off-site releases without restriction on use. Common metals with potential volumetric activation are of main interest with technical bases provided in Appendices of the Standard. The clearance protocols in the Standard include three elements: 1 clearance criteria, 2 process knowledge, and 3 measurement methods. This paper presents the technical aspects of the new Standard, discusses operational experience gained in clearance of materials and equipment from several accelerator facilities at SLAC and examples as to how this Standard can be applied to benefit the entirety of the DOE Accelerator Complex.

  11. Native Frames: Disentangling Sequential from Concerted Three-Body Fragmentation

    Science.gov (United States)

    Rajput, Jyoti; Severt, T.; Berry, Ben; Jochim, Bethany; Feizollah, Peyman; Kaderiya, Balram; Zohrabi, M.; Ablikim, U.; Ziaee, Farzaneh; Raju P., Kanaka; Rolles, D.; Rudenko, A.; Carnes, K. D.; Esry, B. D.; Ben-Itzhak, I.

    2018-03-01

    A key question concerning the three-body fragmentation of polyatomic molecules is the distinction of sequential and concerted mechanisms, i.e., the stepwise or simultaneous cleavage of bonds. Using laser-driven fragmentation of OCS into O++C++S+ and employing coincidence momentum imaging, we demonstrate a novel method that enables the clear separation of sequential and concerted breakup. The separation is accomplished by analyzing the three-body fragmentation in the native frame associated with each step and taking advantage of the rotation of the intermediate molecular fragment, CO2 + or CS2 + , before its unimolecular dissociation. This native-frame method works for any projectile (electrons, ions, or photons), provides details on each step of the sequential breakup, and enables the retrieval of the relevant spectra for sequential and concerted breakup separately. Specifically, this allows the determination of the branching ratio of all these processes in OCS3 + breakup. Moreover, we find that the first step of sequential breakup is tightly aligned along the laser polarization and identify the likely electronic states of the intermediate dication that undergo unimolecular dissociation in the second step. Finally, the separated concerted breakup spectra show clearly that the central carbon atom is preferentially ejected perpendicular to the laser field.

  12. AXEL–2014: Introduction to Particle Accelerators

    CERN Multimedia

    2014-01-01

    AXEL-2014 is a series of courses on particle accelerators, given at CERN within the framework of the 2014 Technical Training Program. As part of the BE Department’s Operation Group Shutdown Lecture series, the general accelerator physics module has been organised since 2003 as a joint venture between the BE Department and Technical Training, and is open to the wider CERN community.   The AXEL-2014 course series is designed for technicians who are operating an accelerator or whose work is closely linked to accelerators, but it is also open to technicians, engineers, and physicists interested in this field. The course does not require any prior knowledge of accelerators. However, some basic knowledge of trigonometry, matrices and differential equations, and some basic knowledge of magnetism would be an advantage. The series will be composed of 10 modules (Monday 24 March 2014 – Fri 28 March 2014, from 9 a.m. to 10:15 a.m. and from 10:45 a.m. to 12 noon), and will be given in En...

  13. The electronic logbook for LNL accelerators

    International Nuclear Information System (INIS)

    Canella, S.; Carletto, O.

    2012-01-01

    In spring 2009 all run-time data concerning the particle accelerators at LNL (Legnaro National Laboratory) were still registered mainly on paper. The electrostatic accelerator TANDEM-XTU and its Negative Source data were logged on a large format paper logbook. For the ALPI booster and the PIAVE injector with its Positive ECR Source a number of independent paper notebooks were used, together with plain data files containing raw instant snapshots of the RF super-conductive accelerators. At that time a decision was taken to build a new tool for a general electronic registration of accelerators run-time data. The result of this effort, the LNL electronic logbook, is here presented. The LNL electronic logbook is a many-layers software tool that is made of data sets and software programs. It is used to register states, events, texts, images and files according to the shift structures in the working time of the LNL accelerators. The same system is used to register data and to retrieve them. It may be accessed by standard browser on any platform

  14. Development plan of basic technology for a high intensity proton linear accelerator

    International Nuclear Information System (INIS)

    Mizumoto, M.

    1990-01-01

    The national program called OMEGA (Option Making Extra Gains from Actinide and Fission Products) has started with the aim of promoting the research and development of the new technologies for nuclear waste partitioning and transmutation. As a part of this program, Japan Atomic Energy Research Institute, JAERI, has laid out several R and D plans for accelerator based actinide transmutation. The present article first outlines the status of the high intensity proton linear accelerator. Then it describes the time schedule for the development of a high intensity proton linac, focusing on the first step development (basic technology accelerator), second step development (engineering test accelerator, and third step development (commercial plant). It also outlines the conceptual design study and preliminary design calculations for basic technology accelerator, focusing on general consideration, ion source, radio frequency quadrupole, drift tube linac, and high beta linac. (N.K.)

  15. Practice for beginners programming lesson using App Lab: Introduction of programming learning for undergraduate students

    OpenAIRE

    榊原, 直樹

    2017-01-01

    App Lab is an online programming education environment. It was designed classes of programming for beginners using the App Lab. Through 15 lessons of the class, it was to understand the basic structure of the programming of the sequential-repetition-branch. Students were allowed to complete the game as a final project. The effectiveness of App the Lab has been confirmed from these results.

  16. CO2 laser technology for advanced particle accelerators. Revision

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.

    1996-06-01

    Short-pulse, high-power CO 2 lasers open new prospects for development of ultra-high gradient laser-driven electron accelerators. The advantages of λ=10 μm CO 2 laser radiation over the more widely exploited solid state lasers with λ∼1 μm are based on a λ 2 -proportional ponderomotive potential, λ-proportional phase slippage distance, and λ-proportional scaling of the laser accelerator structures. We show how a picosecond terawatt CO 2 laser that is under construction at the Brookhaven Accelerator Test Facility may benefit the ATF's experimental program of testing far-field, near-field, and plasma accelerator schemes

  17. JAVA CONCURENT PROGRAM FOR THE SMARANDACHE FUNCTION

    OpenAIRE

    Power, David; Tabirca, S.; Tabirca, T.

    2004-01-01

    The aim of this article is to propose a Java concurrent program for the Smarandache fimction based on an equation. Some results concerning the theoretical complexity of this program are proposed. Finally, the experimental results of the sequential and Java programs are given in order to demonstrate the efficiency of the conament implementation.

  18. Campbell and moment measures for finite sequential spatial processes

    NARCIS (Netherlands)

    M.N.M. van Lieshout (Marie-Colette)

    2006-01-01

    textabstractWe define moment and Campbell measures for sequential spatial processes, prove a Campbell-Mecke theorem, and relate the results to their counterparts in the theory of point processes. In particular, we show that any finite sequential spatial process model can be derived as the vector

  19. Accelerated pavement testing of low-volume paved roads with geocell reinforcement.

    Science.gov (United States)

    2015-03-01

    The Midwest States Accelerated Pavement Testing Pooled-Fund Program, financed by the highway : departments of Kansas, Iowa, Missouri, and New York, has supported an accelerated pavement testing (APT) project : to study the rehabilitation of low-volum...

  20. Sequential Dependencies in Driving

    Science.gov (United States)

    Doshi, Anup; Tran, Cuong; Wilder, Matthew H.; Mozer, Michael C.; Trivedi, Mohan M.

    2012-01-01

    The effect of recent experience on current behavior has been studied extensively in simple laboratory tasks. We explore the nature of sequential effects in the more naturalistic setting of automobile driving. Driving is a safety-critical task in which delayed response times may have severe consequences. Using a realistic driving simulator, we find…

  1. Research on parallel algorithm for sequential pattern mining

    Science.gov (United States)

    Zhou, Lijuan; Qin, Bai; Wang, Yu; Hao, Zhongxiao

    2008-03-01

    Sequential pattern mining is the mining of frequent sequences related to time or other orders from the sequence database. Its initial motivation is to discover the laws of customer purchasing in a time section by finding the frequent sequences. In recent years, sequential pattern mining has become an important direction of data mining, and its application field has not been confined to the business database and has extended to new data sources such as Web and advanced science fields such as DNA analysis. The data of sequential pattern mining has characteristics as follows: mass data amount and distributed storage. Most existing sequential pattern mining algorithms haven't considered the above-mentioned characteristics synthetically. According to the traits mentioned above and combining the parallel theory, this paper puts forward a new distributed parallel algorithm SPP(Sequential Pattern Parallel). The algorithm abides by the principal of pattern reduction and utilizes the divide-and-conquer strategy for parallelization. The first parallel task is to construct frequent item sets applying frequent concept and search space partition theory and the second task is to structure frequent sequences using the depth-first search method at each processor. The algorithm only needs to access the database twice and doesn't generate the candidated sequences, which abates the access time and improves the mining efficiency. Based on the random data generation procedure and different information structure designed, this paper simulated the SPP algorithm in a concrete parallel environment and implemented the AprioriAll algorithm. The experiments demonstrate that compared with AprioriAll, the SPP algorithm had excellent speedup factor and efficiency.

  2. Exploring and Improving Student Engagement in an Accelerated Undergraduate Nursing Program through a Mentoring Partnership: An Action Research Study.

    Science.gov (United States)

    Bramble, Marguerite; Maxwell, Hazel; Einboden, Rochelle; Farington, Sally; Say, Richard; Beh, Chin Liang; Stankiewicz, Grace; Munro, Graham; Marembo, Esther; Rickard, Greg

    2018-05-30

    This Participatory Action Research (PAR) project aimed to engage students from an accelerated 'fast track' nursing program in a mentoring collaboration, using an interdisciplinary partnership intervention with a group of academics. Student participants represented the disciplines of nursing and paramedicine with a high proportion of culturally and linguistically diverse (CALD) students. Nine student mentors were recruited and paired with academics for a three-month 'mentorship partnership' intervention. Data from two pre-intervention workshops and a post-intervention workshop were coded in NVivo11 using thematic analysis. Drawing on social inclusion theory, a qualitative analysis explored an iteration of themes across each action cycle. Emergent themes were: 1) 'building relationships for active engagement', 2) 'voicing cultural and social hierarchies', and 3) 'enacting collegiate community'. The study offers insights into issues for contemporary accelerated course delivery with a diverse student population and highlights future strategies to foster effective student engagement.

  3. Accelerated Distributed Dual Averaging Over Evolving Networks of Growing Connectivity

    Science.gov (United States)

    Liu, Sijia; Chen, Pin-Yu; Hero, Alfred O.

    2018-04-01

    We consider the problem of accelerating distributed optimization in multi-agent networks by sequentially adding edges. Specifically, we extend the distributed dual averaging (DDA) subgradient algorithm to evolving networks of growing connectivity and analyze the corresponding improvement in convergence rate. It is known that the convergence rate of DDA is influenced by the algebraic connectivity of the underlying network, where better connectivity leads to faster convergence. However, the impact of network topology design on the convergence rate of DDA has not been fully understood. In this paper, we begin by designing network topologies via edge selection and scheduling. For edge selection, we determine the best set of candidate edges that achieves the optimal tradeoff between the growth of network connectivity and the usage of network resources. The dynamics of network evolution is then incurred by edge scheduling. Further, we provide a tractable approach to analyze the improvement in the convergence rate of DDA induced by the growth of network connectivity. Our analysis reveals the connection between network topology design and the convergence rate of DDA, and provides quantitative evaluation of DDA acceleration for distributed optimization that is absent in the existing analysis. Lastly, numerical experiments show that DDA can be significantly accelerated using a sequence of well-designed networks, and our theoretical predictions are well matched to its empirical convergence behavior.

  4. Topics in radiation at accelerators: Radiation physics for personnel and environmental protection

    International Nuclear Information System (INIS)

    Cossairt, J.D.

    1996-10-01

    In the first chapter, terminology, physical and radiological quantities, and units of measurement used to describe the properties of accelerator radiation fields are reviewed. The general considerations of primary radiation fields pertinent to accelerators are discussed. The primary radiation fields produced by electron beams are described qualitatively and quantitatively. In the same manner the primary radiation fields produced by proton and ion beams are described. Subsequent chapters describe: shielding of electrons and photons at accelerators; shielding of proton and ion accelerators; low energy prompt radiation phenomena; induced radioactivity at accelerators; topics in radiation protection instrumentation at accelerators; and accelerator radiation protection program elements

  5. Results of LIA-10M accelerator investigations

    CERN Document Server

    Gordeev, V S; Filippov, V O

    2001-01-01

    There are presented basic results of experiments on the LIA-10M accelerator since its putting into operation (1994) till today. There were investigated various modes of accelerator operation and its output characteristics depending on the parameters of injected electron beam,number of connected accelerator modules,time program of inductors switch-in etc. There was obtained a large scope of experimental data that are of interest for LIA-10M accelerator practical use and for the development of new facilities of this type. The investigations that have been performed recently make it possible to considerably (half as much again) increase the output dose parameters of the accelerator as compared to the level achieved before:maximal dose(Si) and dose rate on the output flange constitute 400 Gy and 2.5 centre dot 10 Gy/s, while at a 1 meter distance from the target they are equal to 7.5 Gy and 5 centre dot 10 sup 8 Gy/s, respectively.

  6. Promoting International Cooperation and Public Acceptance in Utilizing Proton Accelerator Technology

    International Nuclear Information System (INIS)

    Choi, Byung Ho; Hahn, Bong Oh; Lee, Jae Hyung; Kim, Kyu Ryung; Joo, Po Kook; Kim, In Kyu; Kim, Hyun Joon; Noh, Seung Jeong

    2002-11-01

    Proton engineering's main tool will be a high power proton accelerator which is to be established within next 10 years in the frame of Proton engineering Frontier Project. It is necessary for public to understand the meaning and importance of the project so that Project activities such as site preparation can be efficiently completed. And, it is required to establish a sound plan of international cooperation, and to develop user program to establish domestic foundation in utilizing the accelerator. Along with public relations activities through newspapers and broadcasting, there were more than 20 times of project presentations requested by various local governments, universities, and scientific societies. which resulted in strong support of the project from various societies. Based on collected information through actual visits to and internet surveys on foreign accelerators, a recommendation of international cooperation scheme has been made to complement domestic technological weak points, and there were discussions with some foreign organizations for that purpose. Especially, KEK of Japan, IHEP of China and KAERI have been deliberating on planning detail cooperation programs in developing and utilizing accelerator among 3 countries Some research items related with NT/BT/IT and utilizing proton beam were planned to be implemented in the Project. And a user program implemented in the Project In order to be prepared for future use of the accelerator. In order to upbring junior researchers for future days, an accelerator summer school has been planned to be held annually inviting prominent foreign and domestic lecturers

  7. Implementation of a hepatitis A/B vaccination program using an accelerated schedule among high-risk inmates, Los Angeles County Jail, 2007-2010.

    Science.gov (United States)

    Costumbrado, John; Stirland, Ali; Cox, Garrett; El-Amin, Alvin Nelson; Miranda, Armidia; Carter, Ann; Malek, Mark

    2012-11-06

    The Centers for Disease Control and Prevention recommend vaccination for men who have sex with men (MSM) and injection drug users against hepatitis A and B. This study is the first report of a hepatitis vaccination program in a United States jail with a combined vaccine using an accelerated schedule. Los Angeles County has the largest jail system in the nation and Men's Central Jail (MCJ) is the largest facility within that system. MCJ includes a unit for self-identified MSM, where approximately 2700 inmates are housed per year. Starting in August 2007, a combined hepatitis A and B vaccine was offered to all inmates housed in this special unit. Using an accelerated schedule (0-, 7-, 21-30 days, 12-month booster), a total of 3931 doses were administered to 1633 inmates as of June 2010. Of those, 77% received 2 doses, 58% received 3 doses, and 11% received the booster dose. Inmates who screened positive for a sexually transmitted infection in this unit were 1.3 times more likely to be vaccinated (95% CI 1.2-1.4) compared to others in the same housing unit who screened negative. Hepatitis vaccination initiatives can be successfully implemented in an urban jail among an extremely high-risk population using the accelerated, combined hepatitis A/B vaccine. Ours may be a useful model for other programs to vaccinate incarcerated populations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Neural network-based sensor signal accelerator.

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, M. C.

    2000-10-16

    A strategy has been developed to computationally accelerate the response time of a generic electronic sensor. The strategy can be deployed as an algorithm in a control system or as a physical interface (on an embedded microcontroller) between a slower responding external sensor and a higher-speed control system. Optional code implementations are available to adjust algorithm performance when computational capability is limited. In one option, the actual sensor signal can be sampled at the slower rate with adaptive linear neural networks predicting the sensor's future output and interpolating intermediate synthetic output values. In another option, a synchronized collection of predictors sequentially controls the corresponding synthetic output voltage. Error is adaptively corrected in both options. The core strategy has been demonstrated with automotive oxygen sensor data. A prototype interface device is under construction. The response speed increase afforded by this strategy could greatly offset the cost of developing a replacement sensor with a faster physical response time.

  9. Accelerator development at Bates

    International Nuclear Information System (INIS)

    Sargent, C.P.

    1983-01-01

    The past year has seen the completion of a major expansion of the Bates Accelerator Laboratory. A second experimental hall, South Hall, and several magnetic spectrometers have been constructed. The accelerator's maximum energy has been raised from 400 to 750 MeV by means of beam recirculation. A current two-year project for the fabrication of an additional RF transmitter plus a 30% increase in RF peak power capability will increase energy further to ca. 1 GeV. During the same period pulse-to-pulse beam sharing between the high-resolution spectrometer area and South Hall will become available. In January 1981 the Laboratory submitted their ''Proposal for a Long-Range Expansion Program'' to DOE-NSF. The proposed development consists of three stages. Stage I calls for the addition of a pulse stretcher ring to furnish a CW beam to the South Hall beam lines. Additional experimental space for internal target experiments and photon tagging research are also included. Stage II increases the accelerator energy to 2.1 GeV (at 140 microamps) by means of a five-pass head-to-tail recirculator. Stage III is, at this time, a plan rather than a proposal. It increases accelerator energy to 4 GeV by extending the accelerator length and power and adds another pulse stretcher ring and three new experimental areas for the higher energy work. This paper discusses each of these stages in detail and recommends their funding and scheduling

  10. Phase 2 Trial of Accelerated, Hypofractionated Whole-Breast Irradiation of 39 Gy in 13 Fractions Followed by a Tumor Bed Boost Sequentially Delivering 9 Gy in 3 Fractions in Early-Stage Breast Cancer

    International Nuclear Information System (INIS)

    Kim, Ja Young; Jung, So-Youn; Lee, Seeyoun; Kang, Han-Sung; Lee, Eun Sook; Park, In Hae; Lee, Keun Seok; Ro, Jungsil; Lee, Nam Kwon; Shin, Kyung Hwan

    2013-01-01

    Purpose: To report a phase 2 trial of accelerated, hypofractionated whole-breast irradiation (AH-WBI) delivered as a daily dose of 3 Gy to the whole breast followed by a tumor bed boost. Methods and Materials: Two hundred seventy-six patients diagnosed with breast cancer (pT1-2 and pN0-1a) who had undergone breast-conserving surgery in which the operative margins were negative were treated with AH-WBI delivered as 39 Gy in 13 fractions of 3 Gy to the whole breast once daily over 5 consecutive working days, and 9 Gy in 3 sequential fractions of 3 Gy to a lumpectomy cavity, all within 3.2 weeks. Results: After a median follow-up period of 57 months (range: 27-75 months), the rate of 5-year locoregional recurrence was 1.4% (n=4), whereas that of disease-free survival was 97.4%. No grade 3 skin toxicity was reported during the follow-up period. Qualitative physician cosmetic assessments of good or excellent were noted in 82% of the patients at 2 months after the completion of AH-WBI. The global cosmetic outcome did not worsen over time, and a good or excellent cosmetic outcome was reported in 82% of the patients at 3 years. The mean pretreatment percentage breast retraction assessment was 12.00 (95% confidence interval [CI]: 11.14-12.86). The mean value of percentage breast retraction assessment increased to 13.99 (95% CI: 12.17-15.96) after 1 year and decreased to 13.54 (95% CI: 11.84-15.46) after 3 years but was not significant (P>.05). Conclusions: AH-WBI consisting of 39 Gy in 13 fractions followed by a tumor bed boost sequentially delivering 9 Gy in 3 fractions can be delivered with excellent disease control and tolerable skin toxicity in patients with early-stage breast cancer after breast-conserving surgery

  11. A Survey of Multi-Objective Sequential Decision-Making

    OpenAIRE

    Roijers, D.M.; Vamplew, P.; Whiteson, S.; Dazeley, R.

    2013-01-01

    Sequential decision-making problems with multiple objectives arise naturally in practice and pose unique challenges for research in decision-theoretic planning and learning, which has largely focused on single-objective settings. This article surveys algorithms designed for sequential decision-making problems with multiple objectives. Though there is a growing body of literature on this subject, little of it makes explicit under what circumstances special methods are needed to solve multi-obj...

  12. Superconductor Requirements and Characterization for High Field Accelerator Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Barzi, E.; Zlobin, A. V.

    2015-05-01

    The 2014 Particle Physics Project Prioritization Panel (P5) strategic plan for U.S. High Energy Physics (HEP) endorses a continued world leadership role in superconducting magnet technology for future Energy Frontier Programs. This includes 10 to 15 T Nb3Sn accelerator magnets for LHC upgrades and a future 100 TeV scale pp collider, and as ultimate goal that of developing magnet technologies above 20 T based on both High Temperature Superconductors (HTS) and Low Temperature Superconductors (LTS) for accelerator magnets. To achieve these objectives, a sound conductor development and characterization program is needed and is herein described. This program is intended to be conducted in close collaboration with U.S. and International labs, Universities and Industry.

  13. submitter Towards REBCO 20T+ dipoles for accelerators

    CERN Document Server

    van Nugteren, Jeroen; Murtomäki, Jaakko; DeRijk, Gijs; Rossi, Lucio; Stenvall, Antti

    2018-01-01

    ReBCO high temperature superconducting (HTS) coated conductor tapes are a promising candidate for pushing the magnetic fields in accelerator magnets well beyond 20 T. They are capable of very high current densities in intense applied magnetic field, have a very high thermal stability, can withstand high transverse pressures and allow operation in 20–30 K helium gas flow, potentially reducing operating cost significantly. During the EuCARD2 program, significant developments have been made in terms of coil design, manufacturing, and testing. Now that EuCARD2 has come to an end, CERN and collaborators are initiating a new program to continue the development of HTS accelerator magnets. This paper presents our initial thoughts on the conceptual design of a 20 T+ accelerator magnet, using the results and technologies from EuCARD2 combined with some new ideas. The paper discusses the options available for the cross-sectional layout, the use of a hybrid configurations, including Aligned Block, the design of the coi...

  14. A Sequential Multiplicative Extended Kalman Filter for Attitude Estimation Using Vector Observations

    Science.gov (United States)

    Qin, Fangjun; Jiang, Sai; Zha, Feng

    2018-01-01

    In this paper, a sequential multiplicative extended Kalman filter (SMEKF) is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms. PMID:29751538

  15. A Sequential Multiplicative Extended Kalman Filter for Attitude Estimation Using Vector Observations

    Directory of Open Access Journals (Sweden)

    Fangjun Qin

    2018-05-01

    Full Text Available In this paper, a sequential multiplicative extended Kalman filter (SMEKF is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms.

  16. Asynchronous Operators of Sequential Logic Venjunction & Sequention

    CERN Document Server

    Vasyukevich, Vadim

    2011-01-01

    This book is dedicated to new mathematical instruments assigned for logical modeling of the memory of digital devices. The case in point is logic-dynamical operation named venjunction and venjunctive function as well as sequention and sequentional function. Venjunction and sequention operate within the framework of sequential logic. In a form of the corresponding equations, they organically fit analytical expressions of Boolean algebra. Thus, a sort of symbiosis is formed using elements of asynchronous sequential logic on the one hand and combinational logic on the other hand. So, asynchronous

  17. Method for accelerated leaching of solidified waste

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Heiser, J.H.; Pietrzak, R.F.; Franz, E.M.; Colombo, P.

    1990-11-01

    An accelerated leach test method has been developed to determine the maximum leachability of solidified waste. The approach we have taken is to use a semi-dynamic leach test; that is, the leachant is sampled and replaced periodically. Parameters such as temperature, leachant volume, and specimen size are used to obtain releases that are accelerated relative to other standard leach tests and to the leaching of full-scale waste forms. The data obtained with this test can be used to model releases from waste forms, or to extrapolate from laboratory-scale to full-scale waste forms if diffusion is the dominant leaching mechanism. Diffusion can be confirmed as the leaching mechanism by using a computerized mathematical model for diffusion from a finite cylinder. We have written a computer program containing several models including diffusion to accompany this test. The program and a Users' Guide that gives screen-by-screen instructions on the use of the program are available from the authors. 14 refs., 4 figs., 1 tab

  18. Controls and Beam Diagnostics for Therapy-Accelerators

    CERN Document Server

    Eickhoff, H

    2000-01-01

    During the last four years GSI has developed a new procedure for cancer treatment by means of the intensity controlled rasterscan-method. This method includes active variations of beam parameters during the treatment session and the integration of 'on-line' PET monitoring. Starting in 1997 several patients have been successfully treated within this GSI experimental cancer treatment program; within this program about 350 patients shall be treated in the next 5 years. The developments and experiences of this program accompanied by intensive discussions with the medical community led to a proposal for a hospital based light ion accelerator facility for the clinic in Heidelberg. An essential part for patients treatments is the measurement of the beam properties within acceptance and constancy tests and especially for the rasterscan method during the treatment sessions. The presented description of the accelerator controls and beam diagnostic devices mainly covers the requests for the active scanning method, which...

  19. Object-oriented accelerator design with HPF

    International Nuclear Information System (INIS)

    Ji Qiang; Ryne, R.D.; Habib, S.

    1998-01-01

    In this paper, object-oriented design is applied to codes for beam dynamics simulations in accelerators using High Performance Fortran (HPF). This results in good maintainability, reusability, and extensibility of software, combined with the ease of parallel programming provided by HPF

  20. Object-oriented accelerator design with HPF

    Energy Technology Data Exchange (ETDEWEB)

    Ji Qiang; Ryne, R.D.; Habib, S.

    1998-12-31

    In this paper, object-oriented design is applied to codes for beam dynamics simulations in accelerators using High Performance Fortran (HPF). This results in good maintainability, reusability, and extensibility of software, combined with the ease of parallel programming provided by HPF.

  1. Human visual system automatically encodes sequential regularities of discrete events.

    Science.gov (United States)

    Kimura, Motohiro; Schröger, Erich; Czigler, István; Ohira, Hideki

    2010-06-01

    For our adaptive behavior in a dynamically changing environment, an essential task of the brain is to automatically encode sequential regularities inherent in the environment into a memory representation. Recent studies in neuroscience have suggested that sequential regularities embedded in discrete sensory events are automatically encoded into a memory representation at the level of the sensory system. This notion is largely supported by evidence from investigations using auditory mismatch negativity (auditory MMN), an event-related brain potential (ERP) correlate of an automatic memory-mismatch process in the auditory sensory system. However, it is still largely unclear whether or not this notion can be generalized to other sensory modalities. The purpose of the present study was to investigate the contribution of the visual sensory system to the automatic encoding of sequential regularities using visual mismatch negativity (visual MMN), an ERP correlate of an automatic memory-mismatch process in the visual sensory system. To this end, we conducted a sequential analysis of visual MMN in an oddball sequence consisting of infrequent deviant and frequent standard stimuli, and tested whether the underlying memory representation of visual MMN generation contains only a sensory memory trace of standard stimuli (trace-mismatch hypothesis) or whether it also contains sequential regularities extracted from the repetitive standard sequence (regularity-violation hypothesis). The results showed that visual MMN was elicited by first deviant (deviant stimuli following at least one standard stimulus), second deviant (deviant stimuli immediately following first deviant), and first standard (standard stimuli immediately following first deviant), but not by second standard (standard stimuli immediately following first standard). These results are consistent with the regularity-violation hypothesis, suggesting that the visual sensory system automatically encodes sequential

  2. A Bayesian Theory of Sequential Causal Learning and Abstract Transfer.

    Science.gov (United States)

    Lu, Hongjing; Rojas, Randall R; Beckers, Tom; Yuille, Alan L

    2016-03-01

    Two key research issues in the field of causal learning are how people acquire causal knowledge when observing data that are presented sequentially, and the level of abstraction at which learning takes place. Does sequential causal learning solely involve the acquisition of specific cause-effect links, or do learners also acquire knowledge about abstract causal constraints? Recent empirical studies have revealed that experience with one set of causal cues can dramatically alter subsequent learning and performance with entirely different cues, suggesting that learning involves abstract transfer, and such transfer effects involve sequential presentation of distinct sets of causal cues. It has been demonstrated that pre-training (or even post-training) can modulate classic causal learning phenomena such as forward and backward blocking. To account for these effects, we propose a Bayesian theory of sequential causal learning. The theory assumes that humans are able to consider and use several alternative causal generative models, each instantiating a different causal integration rule. Model selection is used to decide which integration rule to use in a given learning environment in order to infer causal knowledge from sequential data. Detailed computer simulations demonstrate that humans rely on the abstract characteristics of outcome variables (e.g., binary vs. continuous) to select a causal integration rule, which in turn alters causal learning in a variety of blocking and overshadowing paradigms. When the nature of the outcome variable is ambiguous, humans select the model that yields the best fit with the recent environment, and then apply it to subsequent learning tasks. Based on sequential patterns of cue-outcome co-occurrence, the theory can account for a range of phenomena in sequential causal learning, including various blocking effects, primacy effects in some experimental conditions, and apparently abstract transfer of causal knowledge. Copyright © 2015

  3. Linear accelerator for radioisotope production

    International Nuclear Information System (INIS)

    Hansborough, L.D.; Hamm, R.W.; Stovall, J.E.

    1982-02-01

    A 200- to 500-μA source of 70- to 90-MeV protons would be a valuable asset to the nuclear medicine program. A linear accelerator (linac) can achieve this performance, and it can be extended to even higher energies and currents. Variable energy and current options are available. A 70-MeV linac is described, based on recent innovations in linear accelerator technology; it would be 27.3 m long and cost approx. $6 million. By operating the radio-frequency (rf) power system at a level necessary to produce a 500-μA beam current, the cost of power deposited in the radioisotope-production target is comparable with existing cyclotrons. If the rf-power system is operated at full power, the same accelerator is capable of producing an 1140-μA beam, and the cost per beam watt on the target is less than half that of comparable cyclotrons

  4. Impact of Diagrams on Recalling Sequential Elements in Expository Texts.

    Science.gov (United States)

    Guri-Rozenblit, Sarah

    1988-01-01

    Examines the instructional effectiveness of abstract diagrams on recall of sequential relations in social science textbooks. Concludes that diagrams assist significantly the recall of sequential relations in a text and decrease significantly the rate of order mistakes. (RS)

  5. Commissioning the GTA accelerator

    International Nuclear Information System (INIS)

    Sander, O.R.; Atkins, W.H.; Bolme, G.O.; Bowling, S.; Brown, S.; Cole, R.; Gilpatrick, J.D.; Garnett, R.; Guy, F.W.; Ingalls, W.B.; Johnson, K.F.; Kerstiens, D.; Little, C.; Lohsen, R.A.; Lloyd, S.; Lysenko, W.P.; Mottershead, C.T.; Neuschaefer, G.; Power, J.; Rusthoi, D.P.; Sandoval, D.P. Stevens, R.R. Jr.; Vaughn, G.; Wadlinger, E.A.; Yuan, V.; Connolly, R.; Weiss, R.; Saadatmand, K.

    1992-01-01

    The Ground Test Accelerator (GTA) is supported by the Strategic Defense command as part of their Neutral Particle Beam (NPB) program. Neutral particles have the advantage that in space they are unaffected by the earth's magnetic field and travel in straight lines unless they enter the earth's atmosphere and become charged by stripping. Heavy particles are difficult to stop and can probe the interior of space vehicles; hence, NPB can function as a discriminator between warheads and decoys. We are using GTA to resolve the physics and engineering issues related to accelerating, focusing, and steering a high-brightness, high-current H - beam and then neutralizing it. Our immediate goal is to produce a 24-MeV, 50mA device with a 2% duty factor

  6. Quantum Probability Zero-One Law for Sequential Terminal Events

    Science.gov (United States)

    Rehder, Wulf

    1980-07-01

    On the basis of the Jauch-Piron quantum probability calculus a zero-one law for sequential terminal events is proven, and the significance of certain crucial axioms in the quantum probability calculus is discussed. The result shows that the Jauch-Piron set of axioms is appropriate for the non-Boolean algebra of sequential events.

  7. Accelerated testing for studying pavement design and performance (FY 2003) : research summary.

    Science.gov (United States)

    2008-01-01

    The Midwest States Accelerated Pavement Testing Pooled Fund Program, financed by : the highway departments of Missouri, Iowa, Kansas and Nebraska, has supported an : accelerated pavement testing (APT) project to compare the performance of stabilized ...

  8. A path-level exact parallelization strategy for sequential simulation

    Science.gov (United States)

    Peredo, Oscar F.; Baeza, Daniel; Ortiz, Julián M.; Herrero, José R.

    2018-01-01

    Sequential Simulation is a well known method in geostatistical modelling. Following the Bayesian approach for simulation of conditionally dependent random events, Sequential Indicator Simulation (SIS) method draws simulated values for K categories (categorical case) or classes defined by K different thresholds (continuous case). Similarly, Sequential Gaussian Simulation (SGS) method draws simulated values from a multivariate Gaussian field. In this work, a path-level approach to parallelize SIS and SGS methods is presented. A first stage of re-arrangement of the simulation path is performed, followed by a second stage of parallel simulation for non-conflicting nodes. A key advantage of the proposed parallelization method is to generate identical realizations as with the original non-parallelized methods. Case studies are presented using two sequential simulation codes from GSLIB: SISIM and SGSIM. Execution time and speedup results are shown for large-scale domains, with many categories and maximum kriging neighbours in each case, achieving high speedup results in the best scenarios using 16 threads of execution in a single machine.

  9. Present status of accelerator-based BNCT: Focus on developments in Argentina

    International Nuclear Information System (INIS)

    Cartelli, D.; Capoulat, M.E.; Bergueiro, J.; Gagetti, L.; Suárez Anzorena, M.; Grosso, M.F. del; Baldo, M.; Castell, W.; Padulo, J.; Suárez Sandín, J.C.; Igarzabal, M.; Erhardt, J.; Mercuri, D.

    2015-01-01

    In this work we provide some information on the present status of accelerator-based BNCT (AB-BNCT) worldwide and subsequently concentrate on the recent accelerator technology developments in Argentina. - Highlights: • The current status of projects and associated facilities for AB-BNCT worldwide is shown. • Only low (few MeV) energy accelerators are included. • The recent progress of the Argentine AB-BNCT program is described.

  10. Concatenated coding system with iterated sequential inner decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis; Paaske, Erik

    1995-01-01

    We describe a concatenated coding system with iterated sequential inner decoding. The system uses convolutional codes of very long constraint length and operates on iterations between an inner Fano decoder and an outer Reed-Solomon decoder......We describe a concatenated coding system with iterated sequential inner decoding. The system uses convolutional codes of very long constraint length and operates on iterations between an inner Fano decoder and an outer Reed-Solomon decoder...

  11. Accelerating simulation for the multiple-point statistics algorithm using vector quantization

    Science.gov (United States)

    Zuo, Chen; Pan, Zhibin; Liang, Hao

    2018-03-01

    Multiple-point statistics (MPS) is a prominent algorithm to simulate categorical variables based on a sequential simulation procedure. Assuming training images (TIs) as prior conceptual models, MPS extracts patterns from TIs using a template and records their occurrences in a database. However, complex patterns increase the size of the database and require considerable time to retrieve the desired elements. In order to speed up simulation and improve simulation quality over state-of-the-art MPS methods, we propose an accelerating simulation for MPS using vector quantization (VQ), called VQ-MPS. First, a variable representation is presented to make categorical variables applicable for vector quantization. Second, we adopt a tree-structured VQ to compress the database so that stationary simulations are realized. Finally, a transformed template and classified VQ are used to address nonstationarity. A two-dimensional (2D) stationary channelized reservoir image is used to validate the proposed VQ-MPS. In comparison with several existing MPS programs, our method exhibits significantly better performance in terms of computational time, pattern reproductions, and spatial uncertainty. Further demonstrations consist of a 2D four facies simulation, two 2D nonstationary channel simulations, and a three-dimensional (3D) rock simulation. The results reveal that our proposed method is also capable of solving multifacies, nonstationarity, and 3D simulations based on 2D TIs.

  12. Status of spallation neutron source program in High Intensity Proton Accelerator Project

    International Nuclear Information System (INIS)

    Oyama, Yukio

    2001-01-01

    Japan Atomic Energy Research Institute and High Energy Accelerator Organization are jointly designing a 1 MW spallation neutron source as one of the research facilities planned in the High Intensity Proton Accelerator Project. The spallation neutron source is driven by 3 GeV proton beam with a mercury target and liquid hydrogen moderators. The present status of design for these spallation source and relevant facility is overviewed. (author)

  13. Charged particle accelerators for inertial fusion energy

    International Nuclear Information System (INIS)

    Humphries, S. Jr.

    1991-01-01

    The long history of successful commercial applications of charged-particle accelerators is largely a result of initiative by private industry. The Department of Energy views accelerators mainly as support equipment for particle physicists rather than components of an energy generation program. In FY 91, the DOE spent over 850 M$ on building and supporting accelerators for physics research versus 5 M$ on induction accelerators for fusion energy. The author believes this emphasis is skewed. One must address problems of long-term energy sources to preserve the possibility of basic research by future generations. In this paper, the author reviews the rationale for accelerators as inertial fusion drivers, emphasizing that these devices provide a viable path of fusion energy from viewpoints of both physics and engineering. In this paper, he covered the full range of accelerator fusion applications. Because of space limitations, this paper concentrates on induction linacs for ICF, an approach singled out in recent reports by the National Academy of Sciences and the Fusion Policy Advisory Committee as a promising path to long-term fusion power production. Review papers by Cook, Leung, Franzke, Hofmann and Reiser in these proceedings give details on light ion fusion and RF accelerator studies

  14. Lineup Composition, Suspect Position, and the Sequential Lineup Advantage

    Science.gov (United States)

    Carlson, Curt A.; Gronlund, Scott D.; Clark, Steven E.

    2008-01-01

    N. M. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001) argued that sequential lineups reduce the likelihood of mistaken eyewitness identification. Experiment 1 replicated the design of R. C. L. Lindsay and G. L. Wells (1985), the first study to show the sequential lineup advantage. However, the innocent suspect was chosen at a lower rate…

  15. Trial Sequential Analysis in systematic reviews with meta-analysis

    Directory of Open Access Journals (Sweden)

    Jørn Wetterslev

    2017-03-01

    Full Text Available Abstract Background Most meta-analyses in systematic reviews, including Cochrane ones, do not have sufficient statistical power to detect or refute even large intervention effects. This is why a meta-analysis ought to be regarded as an interim analysis on its way towards a required information size. The results of the meta-analyses should relate the total number of randomised participants to the estimated required meta-analytic information size accounting for statistical diversity. When the number of participants and the corresponding number of trials in a meta-analysis are insufficient, the use of the traditional 95% confidence interval or the 5% statistical significance threshold will lead to too many false positive conclusions (type I errors and too many false negative conclusions (type II errors. Methods We developed a methodology for interpreting meta-analysis results, using generally accepted, valid evidence on how to adjust thresholds for significance in randomised clinical trials when the required sample size has not been reached. Results The Lan-DeMets trial sequential monitoring boundaries in Trial Sequential Analysis offer adjusted confidence intervals and restricted thresholds for statistical significance when the diversity-adjusted required information size and the corresponding number of required trials for the meta-analysis have not been reached. Trial Sequential Analysis provides a frequentistic approach to control both type I and type II errors. We define the required information size and the corresponding number of required trials in a meta-analysis and the diversity (D2 measure of heterogeneity. We explain the reasons for using Trial Sequential Analysis of meta-analysis when the actual information size fails to reach the required information size. We present examples drawn from traditional meta-analyses using unadjusted naïve 95% confidence intervals and 5% thresholds for statistical significance. Spurious conclusions in

  16. Accelerating cleanup: Paths to closure

    International Nuclear Information System (INIS)

    1998-06-01

    This report describes the status of Environmental Management's (EM's) cleanup program and a direction forward to complete achievement of the 2006 vision. Achieving the 2006 vision results in significant benefits related to accomplishing EM program objectives. As DOE sites accelerate cleanup activities, risks to public health, the environment, and worker safety and health are all reduced. Finding more efficient ways to conduct work can result in making compliance with applicable environmental requirements easier to achieve. Finally, as cleanup activities at sites are completed, the EM program can focus attention and resources on the small number of sites with more complex cleanup challenges. Chapter 1 describes the process by which this report has been developed and what it hopes to accomplish, its relationship to the EM decision-making process, and a general background of the EM mission and program. Chapter 2 describes how the site-by-site projections were constructed, and summarizes, for each of DOE's 11 Operations/Field Offices, the projected costs and schedules for completing the cleanup mission. Chapter 3 presents summaries of the detailed cleanup projections from three of the 11 Operations/Field Offices: Rocky Flats (Colorado), Richland (Washington), and Savannah River (South Carolina). The remaining eight Operations/Field Office summaries are in Appendix E. Chapter 4 reviews the cost drivers, budgetary constraints, and performance enhancements underlying the detailed analysis of the 353 projects that comprise EM's accelerated cleanup and closure effort. Chapter 5 describes a management system to support the EM program. Chapter 6 provides responses to the general comments received on the February draft of this document

  17. Study comparing sequential (neo-adjuvant) versus concurrent chemo-radiotherapy in patients with squamous cell carcinoma

    International Nuclear Information System (INIS)

    Okawa, Tomohiko; Karasawa, Kumiko; Kaneyasu, Yuko; Tanaka, Makiko; Kita-Okawa, Midori; Ishii, Tetsuo

    1994-01-01

    Radiotherapy combined with chemotherapy is still used for standard treatment in patients with locally advanced unresectable cancer. A study was undertaken to compare a sequential (neo-adjuvant) with a simultaneous (concurrent) chemotherapy and radiotherapy program. Neo-adjuvant chemotherapy with cisplatin (80 mg/m 2 i.v. day 1) and 5FU (600 mg/m 2 continuous i.v. day 1-5) every 3 weeks prior to definitive conventional radiotherapy (60-65 Gy), or cisplatin (20 mg/m 2 i.v. day 1-5) and 5FU (250 mg/m 2 continuous i.v. infusion. day 1-14) were given simultaneously for same radiotherapy. Complete response rate was 45% in the sequential treatment and 43% in the simultaneous arm. Leukopenia and other adverse effects were slightly more frequent in the simultaneous arm, but there were no significant differences. These results suggested that individualization of treatment planning and establishment of optimum treatment were most important for combination of chemotherapy and radiotherapy. (author)

  18. Heat accumulation during sequential cortical bone drilling.

    Science.gov (United States)

    Palmisano, Andrew C; Tai, Bruce L; Belmont, Barry; Irwin, Todd A; Shih, Albert; Holmes, James R

    2016-03-01

    Significant research exists regarding heat production during single-hole bone drilling. No published data exist regarding repetitive sequential drilling. This study elucidates the phenomenon of heat accumulation for sequential drilling with both Kirschner wires (K wires) and standard two-flute twist drills. It was hypothesized that cumulative heat would result in a higher temperature with each subsequent drill pass. Nine holes in a 3 × 3 array were drilled sequentially on moistened cadaveric tibia bone kept at body temperature (about 37 °C). Four thermocouples were placed at the center of four adjacent holes and 2 mm below the surface. A battery-driven hand drill guided by a servo-controlled motion system was used. Six samples were drilled with each tool (2.0 mm K wire and 2.0 and 2.5 mm standard drills). K wire drilling increased temperature from 5 °C at the first hole to 20 °C at holes 6 through 9. A similar trend was found in standard drills with less significant increments. The maximum temperatures of both tools increased from drill sizes was found to be insignificant (P > 0.05). In conclusion, heat accumulated during sequential drilling, with size difference being insignificant. K wire produced more heat than its twist-drill counterparts. This study has demonstrated the heat accumulation phenomenon and its significant effect on temperature. Maximizing the drilling field and reducing the number of drill passes may decrease bone injury. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  19. Compiling Scientific Programs for Scalable Parallel Systems

    National Research Council Canada - National Science Library

    Kennedy, Ken

    2001-01-01

    ...). The research performed in this project included new techniques for recognizing implicit parallelism in sequential programs, a powerful and precise set-based framework for analysis and transformation...

  20. Accelerator and Electrodynamics Capability Review

    International Nuclear Information System (INIS)

    Jones, Kevin W.

    2010-01-01

    Los Alamos National Laboratory (LANL) uses capability reviews to assess the science, technology and engineering (STE) quality and institutional integration and to advise Laboratory Management on the current and future health of the STE. Capability reviews address the STE integration that LANL uses to meet mission requirements. The Capability Review Committees serve a dual role of providing assessment of the Laboratory's technical contributions and integration towards its missions and providing advice to Laboratory Management. The assessments and advice are documented in reports prepared by the Capability Review Committees that are delivered to the Director and to the Principal Associate Director for Science, Technology and Engineering (PADSTE). Laboratory Management will use this report for STE assessment and planning. LANL has defined fifteen STE capabilities. Electrodynamics and Accelerators is one of the seven STE capabilities that LANL Management (Director, PADSTE, technical Associate Directors) has identified for review in Fiscal Year (FY) 2010. Accelerators and electrodynamics at LANL comprise a blend of large-scale facilities and innovative small-scale research with a growing focus on national security applications. This review is organized into five topical areas: (1) Free Electron Lasers; (2) Linear Accelerator Science and Technology; (3) Advanced Electromagnetics; (4) Next Generation Accelerator Concepts; and (5) National Security Accelerator Applications. The focus is on innovative technology with an emphasis on applications relevant to Laboratory mission. The role of Laboratory Directed Research and Development (LDRD) in support of accelerators/electrodynamics will be discussed. The review provides an opportunity for interaction with early career staff. Program sponsors and customers will provide their input on the value of the accelerator and electrodynamics capability to the Laboratory mission.

  1. Accelerator and electrodynamics capability review

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Kevin W [Los Alamos National Laboratory

    2010-01-01

    Los Alamos National Laboratory (LANL) uses capability reviews to assess the science, technology and engineering (STE) quality and institutional integration and to advise Laboratory Management on the current and future health of the STE. Capability reviews address the STE integration that LANL uses to meet mission requirements. The Capability Review Committees serve a dual role of providing assessment of the Laboratory's technical contributions and integration towards its missions and providing advice to Laboratory Management. The assessments and advice are documented in reports prepared by the Capability Review Committees that are delivered to the Director and to the Principal Associate Director for Science, Technology and Engineering (PADSTE). Laboratory Management will use this report for STE assessment and planning. LANL has defined fifteen STE capabilities. Electrodynamics and Accelerators is one of the seven STE capabilities that LANL Management (Director, PADSTE, technical Associate Directors) has identified for review in Fiscal Year (FY) 2010. Accelerators and electrodynamics at LANL comprise a blend of large-scale facilities and innovative small-scale research with a growing focus on national security applications. This review is organized into five topical areas: (1) Free Electron Lasers; (2) Linear Accelerator Science and Technology; (3) Advanced Electromagnetics; (4) Next Generation Accelerator Concepts; and (5) National Security Accelerator Applications. The focus is on innovative technology with an emphasis on applications relevant to Laboratory mission. The role of Laboratory Directed Research and Development (LDRD) in support of accelerators/electrodynamics will be discussed. The review provides an opportunity for interaction with early career staff. Program sponsors and customers will provide their input on the value of the accelerator and electrodynamics capability to the Laboratory mission.

  2. Cost-effectiveness of simultaneous versus sequential surgery in head and neck reconstruction.

    Science.gov (United States)

    Wong, Kevin K; Enepekides, Danny J; Higgins, Kevin M

    2011-02-01

    To determine whether simultaneous (ablation and reconstruction overlaps by two teams) head and neck reconstruction is cost effective compared to sequentially (ablation followed by reconstruction) performed surgery. Case-controlled study. Tertiary care hospital. Oncology patients undergoing free flap reconstruction of the head and neck. A match paired comparison study was performed with a retrospective chart review examining the total time of surgery for sequential and simultaneous surgery. Nine patients were selected for both the sequential and simultaneous groups. Sequential head and neck reconstruction patients were pair matched with patients who had undergone similar oncologic ablative or reconstructive procedures performed in a simultaneous fashion. A detailed cost analysis using the microcosting method was then undertaken looking at the direct costs of the surgeons, anesthesiologist, operating room, and nursing. On average, simultaneous surgery required 3 hours 15 minutes less operating time, leading to a cost savings of approximately $1200/case when compared to sequential surgery. This represents approximately a 15% reduction in the cost of the entire operation. Simultaneous head and neck reconstruction is more cost effective when compared to sequential surgery.

  3. Accelerator driven light water fast reactor (revisiting to the accelerator LWR fuel regenerator)

    International Nuclear Information System (INIS)

    Takahashi, H.; Zhang, J.

    1999-01-01

    A tight-latticed, high-enriched Pu fuel reactor cooled by water or by super-critical steam has a high neutron economy, similar to that of Na-or Pb-cooled fast reactor. Operating in a subcritical condition by providing spallation neutrons, this Pu-fueled reactor can run safely, despite the positive coolant void coefficients. It can be used to transmute the proliferation-prone Pu into proliferation-resistive U-233 fuel using thorium as the fertile material. Rather than employing the large linear accelerator proposed for the LWR fuel regenerator studied in the INFCE program, a small circular accelerator, such as a cyclotron or a Fixed Field Alternating Gradient Synchrotron (FFAG), can run a large power reactor in a slightly subcritical reactor using control rods, on-line fuel reshuffling, and slightly graded proton-beam injection. Some thoughts on improving the reliability of the proton accelerator, on transmutation of the long-lived fission products of Tc-99, and I-129, and the future direction of the development of the fast reactor are discussed. (author)

  4. Common Ground in Cross-Cultural Communication: Sequential and Institutional Contexts in Front Desk Service Encounters

    OpenAIRE

    Kidwell, Mardi

    2000-01-01

    How do native and nonnative English-speaking participants understand one another in front desk service encounters? Specifically, what are the resources that enable them to transact their business at the desk? In this paper, I use the notion of "shared background" to show how participants at the front desk of a university-sponsored English language program rely on the sequential and institutional contexts in which their talk is produced to accomplish their service activities. In particular, I ...

  5. Heavy Ion Fusion Accelerator Research (HIFAR) year-end report, April 1, 1990--September 30, 1990

    International Nuclear Information System (INIS)

    1990-12-01

    The basic objective of the Heavy Ion Fusion Accelerator Research (HIFAR) program is to assess the suitability of heavy ion accelerators as igniters for Inertial Confinement Fusion (ICF). A specific accelerator technology, induction acceleration, is being studied at the Lawrence Berkeley Laboratory and at the Lawrence Livermore National Laboratory. The HIFAR program addresses the generation of high-power, high-brightness beams of heavy ions, the understanding of the scaling laws in this novel physics regime, and the validation of new accelerator strategies to cut costs. Key elements to be addressed include: (1) beam quality limits set by transverse and longitudinal beam physics; (2) development of induction accelerating modules, and multiple-beam hardware, at affordable costs; (3) acceleration of multiple beams with current amplification without significant dilution of the optical quality of the beams; (4) final bunching, transport, and accurate focusing on a small target

  6. Dihydroazulene photoswitch operating in sequential tunneling regime

    DEFF Research Database (Denmark)

    Broman, Søren Lindbæk; Lara-Avila, Samuel; Thisted, Christine Lindbjerg

    2012-01-01

    to electrodes so that the electron transport goes by sequential tunneling. To assure weak coupling, the DHA switching kernel is modified by incorporating p-MeSC6H4 end-groups. Molecules are prepared by Suzuki cross-couplings on suitable halogenated derivatives of DHA. The synthesis presents an expansion of our......, incorporating a p-MeSC6H4 anchoring group in one end, has been placed in a silver nanogap. Conductance measurements justify that transport through both DHA (high resistivity) and VHF (low resistivity) forms goes by sequential tunneling. The switching is fairly reversible and reenterable; after more than 20 ON...

  7. Sequential search leads to faster, more efficient fragment-based de novo protein structure prediction.

    Science.gov (United States)

    de Oliveira, Saulo H P; Law, Eleanor C; Shi, Jiye; Deane, Charlotte M

    2018-04-01

    Most current de novo structure prediction methods randomly sample protein conformations and thus require large amounts of computational resource. Here, we consider a sequential sampling strategy, building on ideas from recent experimental work which shows that many proteins fold cotranslationally. We have investigated whether a pseudo-greedy search approach, which begins sequentially from one of the termini, can improve the performance and accuracy of de novo protein structure prediction. We observed that our sequential approach converges when fewer than 20 000 decoys have been produced, fewer than commonly expected. Using our software, SAINT2, we also compared the run time and quality of models produced in a sequential fashion against a standard, non-sequential approach. Sequential prediction produces an individual decoy 1.5-2.5 times faster than non-sequential prediction. When considering the quality of the best model, sequential prediction led to a better model being produced for 31 out of 41 soluble protein validation cases and for 18 out of 24 transmembrane protein cases. Correct models (TM-Score > 0.5) were produced for 29 of these cases by the sequential mode and for only 22 by the non-sequential mode. Our comparison reveals that a sequential search strategy can be used to drastically reduce computational time of de novo protein structure prediction and improve accuracy. Data are available for download from: http://opig.stats.ox.ac.uk/resources. SAINT2 is available for download from: https://github.com/sauloho/SAINT2. saulo.deoliveira@dtc.ox.ac.uk. Supplementary data are available at Bioinformatics online.

  8. Optically isolated electronic trigger system for experiments on a subnanosecond time scale with a pulsed Van de Graaff electron accelerator

    International Nuclear Information System (INIS)

    Luthjens, L.H.; Vermeulen, M.J.W.; Hom, M.L.

    1980-01-01

    An optically isolated electronic trigger system for a pulsed Van de Graaff electron accelerator, producing an external pretrigger pulse 75 ns before arrival of the electron pulse at the target, is described. The total time jitter between trigger signal and electron pulse is 50 ps. The measurement of optical and electrical transients on a subnanosecond time scale with a sequential sampling oscilloscope is demonstrated. The contribution of various parts of the equipment to the total jitter is discussed. Those contributions to the jitter due to the electron transit time fluctuations in the accelerator assuming a constant acceleration voltage gradient and to the shot noise in the photomultiplier detector of the trigger system are calculated to be 5 ps and 12 to 21 ps respectively. Comparison with the experimental results leads to the conclusion that a considerable part of the total jitter may be attributed to acceleration voltage gradient fluctuations, to accelerator vibrations and possibly to density fluctuations in the insulation gas. Possible improvements of the trigger system are discussed. The apparatus is used for pulse radiolysis experiments with subnanosecond time resolution down to 100 ps in combination with subnanosecond time duration electron pulses

  9. Accelerated testing for studying pavement design and performance (FY 2002) : research summary.

    Science.gov (United States)

    2004-01-01

    This report covers the Fiscal Year 2002 project conducted at the Accelerated Testing : Laboratory at Kansas State University. The project was selected and funded by the : Midwest States Accelerated Testing Pooled Fund Program, which includes Iowa, Ka...

  10. Accelerator simulation using computers

    International Nuclear Information System (INIS)

    Lee, M.; Zambre, Y.; Corbett, W.

    1992-01-01

    Every accelerator or storage ring system consists of a charged particle beam propagating through a beam line. Although a number of computer programs exits that simulate the propagation of a beam in a given beam line, only a few provide the capabilities for designing, commissioning and operating the beam line. This paper shows how a ''multi-track'' simulation and analysis code can be used for these applications

  11. Accelerator mass spectrometry in NIPNE

    International Nuclear Information System (INIS)

    Ivascu, M; Marinescu, L.; Dima, R.; Cata-Danil, D.; Petrascu, M.; Popescu, I.; Stan-Sion, C.; Radulescu, M.; Plostinaru, D.

    1997-01-01

    The Accelerator Mass Spectrometry (AMS) is today the method capable to measure the lowest concentration of a particular nuclide in sample materials. The method has applications in environmental physics, medicine, measurements of cosmic-ray or nuclear power plant produced radionuclides in the earth's atmosphere. All over the world, more than 40 charged particles and heavy ion accelerators are performing such analyses concerning the research interest of a huge number of laboratories. The Romanian Institute of Nuclear Physics and Engineering in Bucharest has initiated a construction project for the AMS facility at the FN - Van de Graaff Tandem accelerator. This program benefits of technical and financial assistance provided by IAEA in the frame of the IAEA-TC Project ROM 8014-265C. A general lay-out of the AMS project is presented. The construction work has begun and first tests of the AMS injector will take place between July - September this year. (authors)

  12. Advanced accelerator research and development

    International Nuclear Information System (INIS)

    Anon.

    1974-01-01

    Research and development on the Positron-Electron Project (PEP), the electron rings, the superconducting accelerator (ESCAR), and the superconductivity program are reported. Efforts relating to the proposed PEP include work on: (1) the injection system; (2) the rf system; (3) the main-ring bend magnets; (4) the magnet power supplies and controls; (5) alignment; (6) radiation and shielding; (7) the vacuum system; and (8) conventional facilities (utilities, etc.). Experimental and theoretical work continued on the development of suitably intense electron rings as vehicles for the collective acceleration of ions. The most difficult problem was found to be the longitudinal (negative mass) instability. Design work was begun for ESCAR (Experimental Superconducting Accelerating Ring), a small proton synchrotron and storage ring using superconducting magnets, which should aid in the design of future large superconducting facilities. Magnet development was largely directed toward the detailed design of the dipole units. A superconducting beam transport line was installed at the Bevatron. (PMA)

  13. Synthetic Aperture Sequential Beamforming

    DEFF Research Database (Denmark)

    Kortbek, Jacob; Jensen, Jørgen Arendt; Gammelmark, Kim Løkke

    2008-01-01

    A synthetic aperture focusing (SAF) technique denoted Synthetic Aperture Sequential Beamforming (SASB) suitable for 2D and 3D imaging is presented. The technique differ from prior art of SAF in the sense that SAF is performed on pre-beamformed data contrary to channel data. The objective is to im......A synthetic aperture focusing (SAF) technique denoted Synthetic Aperture Sequential Beamforming (SASB) suitable for 2D and 3D imaging is presented. The technique differ from prior art of SAF in the sense that SAF is performed on pre-beamformed data contrary to channel data. The objective...... is to improve and obtain a more range independent lateral resolution compared to conventional dynamic receive focusing (DRF) without compromising frame rate. SASB is a two-stage procedure using two separate beamformers. First a set of Bmode image lines using a single focal point in both transmit and receive...... is stored. The second stage applies the focused image lines from the first stage as input data. The SASB method has been investigated using simulations in Field II and by off-line processing of data acquired with a commercial scanner. The performance of SASB with a static image object is compared with DRF...

  14. The RF system for the Accelerator Production of Tritium (APT) Low Energy Demonstration Accelerator (LEDA) at Los Alamos

    International Nuclear Information System (INIS)

    Lynch, M.T.; Rees, D.; Tallerico, P.; Regan, A.

    1996-01-01

    To develop and demonstrate the crucial front end of the APT accelerator and some of the critical components for APT, Los Alamos is building a CW proton accelerator (LEDA) to provide 100 mA at up to 40 MeV. LEDA will be installed where the SDI-sponsored Ground Test Accelerator was located. The first accelerating structure for LEDA is a 7-MeV RFQ operating at 350 MHz, followed by several stages of a coupled-cavity Drift Tube Linac (CCDTL) operating at 700 MHz. The first stage of LEDA will go to 12 MeV. Higher energies, up to 40 MeV, come later in the program. Three 1.2-MW CW RF systems will be used to power the RFQ. This paper describes the RF systems being assembled for LEDA, including the 350 and 700-MHz klystrons, the High Voltage Power Supplies, transmitters, RF transport, window/coupler assemblies, and controls. Some of the limitations imposed by the schedule and the building itself are addressed

  15. MEMS-based, RF-driven, compact accelerators

    Science.gov (United States)

    Persaud, A.; Seidl, P. A.; Ji, Q.; Breinyn, I.; Waldron, W. L.; Schenkel, T.; Vinayakumar, K. B.; Ni, D.; Lal, A.

    2017-10-01

    Shrinking existing accelerators in size can reduce their cost by orders of magnitude. Furthermore, by using radio frequency (RF) technology and accelerating ions in several stages, the applied voltages can be kept low paving the way to new ion beam applications. We make use of the concept of a Multiple Electrostatic Quadrupole Array Linear Accelerator (MEQALAC) and have previously shown the implementation of its basic components using printed circuit boards, thereby reducing the size of earlier MEQALACs by an order of magnitude. We now demonstrate the combined integration of these components to form a basic accelerator structure, including an initial beam-matching section. In this presentation, we will discuss the results from the integrated multi-beam ion accelerator and also ion acceleration using RF voltages generated on-board. Furthermore, we will show results from Micro-Electro-Mechanical Systems (MEMS) fabricated focusing wafers, which can shrink the dimension of the system to the sub-mm regime and lead to cheaper fabrication. Based on these proof-of-concept results we outline a scaling path to high beam power for applications in plasma heating in magnetized target fusion and in neutral beam injectors for future Tokamaks. This work was supported by the Office of Science of the US Department of Energy through the ARPA-e ALPHA program under contracts DE-AC02-05CH11231.

  16. Observational probes of cosmic acceleration

    International Nuclear Information System (INIS)

    Weinberg, David H.; Mortonson, Michael J.; Eisenstein, Daniel J.; Hirata, Christopher; Riess, Adam G.; Rozo, Eduardo

    2013-01-01

    The accelerating expansion of the universe is the most surprising cosmological discovery in many decades, implying that the universe is dominated by some form of “dark energy” with exotic physical properties, or that Einstein’s theory of gravity breaks down on cosmological scales. The profound implications of cosmic acceleration have inspired ambitious efforts to understand its origin, with experiments that aim to measure the history of expansion and growth of structure with percent-level precision or higher. We review in detail the four most well established methods for making such measurements: Type Ia supernovae, baryon acoustic oscillations (BAO), weak gravitational lensing, and the abundance of galaxy clusters. We pay particular attention to the systematic uncertainties in these techniques and to strategies for controlling them at the level needed to exploit “Stage IV” dark energy facilities such as BigBOSS, LSST, Euclid, and WFIRST. We briefly review a number of other approaches including redshift-space distortions, the Alcock–Paczynski effect, and direct measurements of the Hubble constant H 0 . We present extensive forecasts for constraints on the dark energy equation of state and parameterized deviations from General Relativity, achievable with Stage III and Stage IV experimental programs that incorporate supernovae, BAO, weak lensing, and cosmic microwave background data. We also show the level of precision required for clusters or other methods to provide constraints competitive with those of these fiducial programs. We emphasize the value of a balanced program that employs several of the most powerful methods in combination, both to cross-check systematic uncertainties and to take advantage of complementary information. Surveys to probe cosmic acceleration produce data sets that support a wide range of scientific investigations, and they continue the longstanding astronomical tradition of mapping the universe in ever greater detail over ever

  17. Observational probes of cosmic acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Weinberg, David H., E-mail: dhw@astronomy.ohio-state.edu [Department of Astronomy, Ohio State University, Columbus, OH (United States); Center for Cosmology and Astro-Particle Physics, Ohio State University, Columbus, OH (United States); Mortonson, Michael J. [Center for Cosmology and Astro-Particle Physics, Ohio State University, Columbus, OH (United States); Eisenstein, Daniel J. [Steward Observatory, University of Arizona, Tucson, AZ (United States); Harvard College Observatory, Cambridge, MA (United States); Hirata, Christopher [California Institute of Technology, Pasadena, CA (United States); Riess, Adam G. [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD (United States); Rozo, Eduardo [Kavli Institute for Cosmological Physics, University of Chicago, Chicago, IL (United States)

    2013-09-10

    The accelerating expansion of the universe is the most surprising cosmological discovery in many decades, implying that the universe is dominated by some form of “dark energy” with exotic physical properties, or that Einstein’s theory of gravity breaks down on cosmological scales. The profound implications of cosmic acceleration have inspired ambitious efforts to understand its origin, with experiments that aim to measure the history of expansion and growth of structure with percent-level precision or higher. We review in detail the four most well established methods for making such measurements: Type Ia supernovae, baryon acoustic oscillations (BAO), weak gravitational lensing, and the abundance of galaxy clusters. We pay particular attention to the systematic uncertainties in these techniques and to strategies for controlling them at the level needed to exploit “Stage IV” dark energy facilities such as BigBOSS, LSST, Euclid, and WFIRST. We briefly review a number of other approaches including redshift-space distortions, the Alcock–Paczynski effect, and direct measurements of the Hubble constant H{sub 0}. We present extensive forecasts for constraints on the dark energy equation of state and parameterized deviations from General Relativity, achievable with Stage III and Stage IV experimental programs that incorporate supernovae, BAO, weak lensing, and cosmic microwave background data. We also show the level of precision required for clusters or other methods to provide constraints competitive with those of these fiducial programs. We emphasize the value of a balanced program that employs several of the most powerful methods in combination, both to cross-check systematic uncertainties and to take advantage of complementary information. Surveys to probe cosmic acceleration produce data sets that support a wide range of scientific investigations, and they continue the longstanding astronomical tradition of mapping the universe in ever greater detail over

  18. Evaluation Using Sequential Trials Methods.

    Science.gov (United States)

    Cohen, Mark E.; Ralls, Stephen A.

    1986-01-01

    Although dental school faculty as well as practitioners are interested in evaluating products and procedures used in clinical practice, research design and statistical analysis can sometimes pose problems. Sequential trials methods provide an analytical structure that is both easy to use and statistically valid. (Author/MLW)

  19. Attack Trees with Sequential Conjunction

    NARCIS (Netherlands)

    Jhawar, Ravi; Kordy, Barbara; Mauw, Sjouke; Radomirović, Sasa; Trujillo-Rasua, Rolando

    2015-01-01

    We provide the first formal foundation of SAND attack trees which are a popular extension of the well-known attack trees. The SAND at- tack tree formalism increases the expressivity of attack trees by intro- ducing the sequential conjunctive operator SAND. This operator enables the modeling of

  20. Applications of High Intensity Proton Accelerators

    Science.gov (United States)

    Raja, Rajendran; Mishra, Shekhar

    2010-06-01

    collider and neutrino factory - summary of working group 2 / J. Galambos, R. Garoby and S. Geer -- Prospects for a very high power CW SRF linac / R. A. Rimmer -- Indian accelerator program for ADS applications / V. C. Sahni and P. Singh -- Ion accelerator activities at VECC (particularly, operating at low temperature) / R. K. Bhandari -- Chinese efforts in high intensity proton accelerators / S. Fu, J. Wang and S. Fang -- ADSR activity in the UK / R. J. Barlow -- ADS development in Japan / K. Kikuchi -- Project-X, SRF, and very large power stations / C. M. Ankenbrandt, R. P. Johnson and M. Popovic -- Power production and ADS / R. Raja -- Experimental neutron source facility based on accelerator driven system / Y. Gohar -- Transmutation mission / W. S. Yang -- Safety performance and issues / J. E. Cahalan -- Spallation target design for accelerator-driven systems / Y. Gohar -- Design considerations for accelerator transmutation of waste system / W. S. Yang -- Japan ADS program / T. Sasa -- Overview of members states' and IAEA activities in the field of Accelerator Driven Systems (ADS) / A. Stanculescu -- Linac for ADS applications - accelerator technologies / R. W. Garnett and R. L. Sheffield -- SRF linacs and accelerator driven sub-critical systems - summary working groups 3 & 4 / J. Delayen -- Production of Actinium-225 via high energy proton induced spallation of Thorium-232 / J. Harvey ... [et al.] -- Search for the electric dipole moment of Radium-225 / R. J. Holt, Z.-T. Lu and R. Mueller -- SRF linac and material science and medicine - summary of working group 5 / J. Nolen, E. Pitcher and H. Kirk.