WorldWideScience

Sample records for accelerated phase chronic

  1. Clinical features in accelerated phase of chronic myeloid leukemia

    International Nuclear Information System (INIS)

    Naqi, N.; Ayub, M.

    2001-01-01

    Objective: To identify the clinical indicators of accelerated phase in chronic myeloid leukemia (CML) diagnosed on hematological findings. Design: An observational and prospective study. Place and Duration of Study: The study was conducted at Oncology department of Combined Military Hospital, Rawalpindi and Armed Forces Institute of Pathology from April 1998 to April 1999. Subjects and Methods: The study on 51 patients of Philadelphia positive CML in chronic phase and on hydroxyurea therapy were carried out. Clinical features and hematological parameters in the peripheral blood examination were recorded and statistical analysis carried out to document reliable clinically indicators of accelerated phase of CML in reference to those reported in the literature. Results: Clinical, presence of unexplained fever, re-enlargement of spleen after successful regression with hydroxyurea therapy, and bleeding diathesis were found to be statistically significant pointers of progression into accelerated phase of CML. In the hematological features, with the exception of peripheral basophilia, the findings in the peripheral blood were consistent with those reported in the literature. Conclusion: It is concluded that the occurrences of the clinical features in the follow-up of chronic myeloid leukemia patients herald the accelerated phase of the disease. (author)

  2. Chronic Subdural Hematoma development in Accelerated phase of Chronic Myeloid Leukaemia presenting with seizure and rapid progression course with fatal outcome

    Directory of Open Access Journals (Sweden)

    Raheja Amol

    2015-06-01

    Full Text Available Occurrence of chronic subdural hematoma (CSDH in leukemia is rare, and most reported cases occurred in relation with acute myeloid leukaemia; however, occurrence is extremely rare in accelerated phase of chronic myelogenous leukaemia (CML. Seizure as presentation of SDH development in CML cases is not reported in literature. Authors report an elderly male, who was diagnosed as CML, accelerated phase of developing SDH. Initially presented to local physician with seizure; urgent CT scan head was advised, but ignored and sensorium rapidly worsened over next day and reported to our emergency department in deeply comatose state, where imaging revealed chronic subdural hematoma with hypoxic brain injury with fatal outcome. Seizure, progressive worsening of headache, vomiting and papilloedema are harbinger of intracranial space occupying lesion and requires CT head in emergency medical department for exclusion, who are receiving treatment of haematological malignancy

  3. Accelerated phase chronic myeloid leukemia: evaluation of clinical criteria as predictors of survival, major cytogenetic response and progression to blast phase

    Directory of Open Access Journals (Sweden)

    Vanessa Fiorini Furtado

    2015-10-01

    Full Text Available BACKGROUND: Published criteria defining the accelerated phase in chronic myeloid leukemia are heterogeneous and little is known about predictors of poor outcome.METHODS: This is a retrospective study of 139 subjects in the accelerated phase of chronic myeloid leukemia treated with imatinib at a single center in Brazil. The objective was to identify risk factors for survival, major cytogenetic response and progression to blast phase in this population. The factors analyzed were: blasts 10-29%, basophils ≥ 20%, platelets > 1 × 106/µL or 1 × 105/µL in the peripheral blood, as well as clonal evolution, splenomegaly, hemoglobin 12 months (p-value = 0.030.CONCLUSION: These data indicate that patients with the above risk factors have a worse prognosis. This information can guide the therapy to be used.

  4. Minimal cross-intolerance with nilotinib in patients with chronic myeloid leukemia in chronic or accelerated phase who are intolerant to imatinib

    Science.gov (United States)

    Hochhaus, Andreas; le Coutre, Philipp D.; Rosti, Gianantonio; Pinilla-Ibarz, Javier; Jabbour, Elias; Gillis, Kathryn; Woodman, Richard C.; Blakesley, Rick E.; Giles, Francis J.; Kantarjian, Hagop M.; Baccarani, Michele

    2011-01-01

    Nilotinib has significant efficacy in patients with newly diagnosed chronic myeloid leukemia in chronic phase (CML-CP) and in patients with CML-CP or CML in accelerated phase (CML-AP) after imatinib failure. We investigated the occurrence of cross-intolerance to nilotinib in imatinib-intolerant patients with CML. Only 1/75 (1%) patients with nonhematologic imatinib intolerance experienced a similar grade 3/4 adverse event (AE), and 3/75 (4%) experienced a similar persistent grade 2 nonhematologic AE on nilotinib. Only 7/40 (18%) patients with hematologic imatinib intolerance discontinued nilotinib, all because of grade 3/4 thrombocytopenia. Ninety percent of imatinib-intolerant patients with CML-CP who did not have complete hematologic response (CHR) at baseline (n = 52) achieved CHR on nilotinib. Nilotinib induced a major cytogenetic response in 66% and 41% of patients with imatinib-intolerant CML-CP and CML-AP (complete cytogenetic response in 51% and 30%), respectively. Minimal cross-intolerance was confirmed in patients with imatinib-intolerant CML. The favorable tolerability of nilotinib in patients with imatinib intolerance leads to alleviation of AE-related symptoms and significant and durable responses. In addition to its established clinical benefit in patients with newly diagnosed CML and those resistant to imatinib, nilotinib is effective and well-tolerated for long-term use in patients with imatinib intolerance. This study is registered at http://www.clinicaltrials.gov as NCT00471497 PMID:21467546

  5. A Phase Matching, Adiabatic Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lemery, Francois [Hamburg U.; Flöttmann, Klaus [DESY; Kärtner, Franz [CFEL, Hamburg; Piot, Philippe [Northern Illinois U.

    2017-05-01

    Tabletop accelerators are a thing of the future. Reducing their size will require scaling down electromagnetic wavelengths; however, without correspondingly high field gradients, particles will be more susceptible to phase-slippage – especially at low energy. We investigate how an adiabatically-tapered dielectric-lined waveguide could maintain phase-matching between the accelerating mode and electron bunch. We benchmark our simple model with CST and implement it into ASTRA; finally we provide a first glimpse into the beam dynamics in a phase-matching accelerator.

  6. Potential mechanisms of disease progression and management of advanced-phase chronic myeloid leukemia

    Science.gov (United States)

    Jabbour, Elias J.; Hughes, Timothy P.; Cortés, Jorge E.; Kantarjian, Hagop M.; Hochhaus, Andreas

    2014-01-01

    Despite vast improvements in treatment of Philadelphia chromosome–positive chronic myeloid leukemia (CML) in chronic phase (CP), advanced stages of CML, accelerated phase or blast crisis, remain notoriously difficult to treat. Treatments that are highly effective against CML-CP produce disappointing results against advanced disease. Therefore, a primary goal of therapy should be to maintain patients in CP for as long as possible, by (1) striving for deep, early molecular response to treatment; (2) using tyrosine kinase inhibitors that lower risk of disease progression; and (3) more closely observing patients who demonstrate cytogenetic risk factors at diagnosis or during treatment. PMID:24050507

  7. Accelerated Aging during Chronic Oxidative Stress: A Role for PARP-1

    Directory of Open Access Journals (Sweden)

    Daniëlle M. P. H. J. Boesten

    2013-01-01

    Full Text Available Oxidative stress plays a major role in the pathophysiology of chronic inflammatory disease and it has also been linked to accelerated telomere shortening. Telomeres are specialized structures at the ends of linear chromosomes that protect these ends from degradation and fusion. Telomeres shorten with each cell division eventually leading to cellular senescence. Research has shown that poly(ADP-ribose polymerase-1 (PARP-1 and subtelomeric methylation play a role in telomere stability. We hypothesized that PARP-1 plays a role in accelerated aging in chronic inflammatory diseases due to its role as coactivator of NF-κb and AP-1. Therefore we evaluated the effect of chronic PARP-1 inhibition (by fisetin and minocycline in human fibroblasts (HF cultured under normal conditions and under conditions of chronic oxidative stress, induced by tert-butyl hydroperoxide (t-BHP. Results showed that PARP-1 inhibition under normal culturing conditions accelerated the rate of telomere shortening. However, under conditions of chronic oxidative stress, PARP-1 inhibition did not show accelerated telomere shortening. We also observed a strong correlation between telomere length and subtelomeric methylation status of HF cells. We conclude that chronic PARP-1 inhibition appears to be beneficial in conditions of chronic oxidative stress but may be detrimental under relatively normal conditions.

  8. Phase-of-flight method for setting the accelerating fields in the ion linear accelerator

    International Nuclear Information System (INIS)

    Dvortsov, S.V.; Lomize, L.G.

    1983-01-01

    For setting amplitudes and phases of accelerating fields in multiresonator ion accelerators presently Δt-procedure is used. The determination and setting of two unknown parameters of RF-field (amplitude and phase) in n-resonator is made according to the two increments of particle time-of-flight, measured experimentally: according to the change of the particle time-of-flight Δt 1 in the n-resonator, during the field switching in the resonator, and according to the change of Δt 2 of the time-of-flight in (n+1) resonator without RF-field with the switching of accelerating field in the n-resonator. When approaching the accelerator exit the particle energy increases, relative energy increment decreases and the accuracy of setting decreases. To enchance the accuracy of accelerating fields setting in a linear ion accelerator a phase-of-flight method is developed, in which for the setting of accelerating fields the measured time-of-flight increment Δt only in one resonator is used (the one in which the change of amplitude and phase is performed). Results of simulation of point bunch motion in the IYaI AN USSR linear accelerator are presented

  9. Spontaneous chronic subdural hematoma development in chronic myeloid leukemia cases at remission phase under maintenance therapy, management strategy - a series with literature review

    Directory of Open Access Journals (Sweden)

    Raheja Amol

    2016-09-01

    Full Text Available Chronic subdural hematoma (CSDH is common squeal of trauma and rarely associated with anticoagulant therapy, antiplatelet, chemotherapeutic drugs, arteriovenous malformation, aneurysms and post-craniotomy. However its occurrence is very unusual with systemic haematological malignancy and mostly reported with acute myeloid leukemia; however incidence of SDH occurrence in chronic myelogenous leukemia (CML is very rare. CML is a haematological malignancy characterized by chromosomal alteration, pathologically represents increased proliferation of the granulocytic cell line without loss of capacity to differentiate. CML has three phases - remission phase, accelerated phase and blast crisis. About 85 % of patients present in remission phase of disease and carries a favorable prognosis. As intracranial, subdural hematoma usually occur in the accelerated phase or blast crisis phase or extremely uncommon during chronic remission phase, although only those affected, who are neglecting therapeutic medication or discontinued therapy or rarely as an adverse effect of medications. However, important role of neurosurgeon lies in early detection and correction of platelet count and associated hematological abnormality as quite sizeable proportion of cases may not need surgical intervention instead can be managed conservatively under regular supervision in association with oncologist colleague, but few cases may need urgent surgical intervention. So, selecting a subgroup of CML cases in the remission phase requiring surgical intervention, presenting with CSDH is not only challenging, as failure to make an informed and timely precise decision can lead to catastrophic worse outcome and even mortality. So, purpose of current article is to formulate the management therapeutic plan. Authors report three cases of CML in chronic remission phase, receiving treatment under guidance of Haemto-oncologist at our institute presented with spontaneous chronic SDH. The mean

  10. Chronic skin inflammation accelerates macrophage cholesterol crystal formation and atherosclerosis

    Science.gov (United States)

    Ng, Qimin; Sanda, Gregory E.; Dey, Amit K.; Teague, Heather L.; Sorokin, Alexander V.; Dagur, Pradeep K.; Silverman, Joanna I.; Harrington, Charlotte L.; Rodante, Justin A.; Rose, Shawn M.; Varghese, Nevin J.; Belur, Agastya D.; Goyal, Aditya; Gelfand, Joel M.; Springer, Danielle A.; Bleck, Christopher K.E.; Thomas, Crystal L.; Yu, Zu-Xi; Winge, Mårten C.G.; Kruth, Howard S.; Marinkovich, M. Peter; Joshi, Aditya A.; Playford, Martin P.; Mehta, Nehal N.

    2018-01-01

    Inflammation is critical to atherogenesis. Psoriasis is a chronic inflammatory skin disease that accelerates atherosclerosis in humans and provides a compelling model to understand potential pathways linking these diseases. A murine model capturing the vascular and metabolic diseases in psoriasis would accelerate our understanding and provide a platform to test emerging therapies. We aimed to characterize a new murine model of skin inflammation (Rac1V12) from a cardiovascular standpoint to identify novel atherosclerotic signaling pathways modulated in chronic skin inflammation. The RacV12 psoriasis mouse resembled the human disease state, including presence of systemic inflammation, dyslipidemia, and cardiometabolic dysfunction. Psoriasis macrophages had a proatherosclerotic phenotype with increased lipid uptake and foam cell formation, and also showed a 6-fold increase in cholesterol crystal formation. We generated a triple-genetic K14-RacV12–/+/Srb1–/–/ApoER61H/H mouse and confirmed psoriasis accelerates atherogenesis (~7-fold increase). Finally, we noted a 60% reduction in superoxide dismutase 2 (SOD2) expression in human psoriasis macrophages. When SOD2 activity was restored in macrophages, their proatherogenic phenotype reversed. We demonstrate that the K14-RacV12 murine model captures the cardiometabolic dysfunction and accelerates vascular disease observed in chronic inflammation and that skin inflammation induces a proatherosclerotic macrophage phenotype with impaired SOD2 function, which associated with accelerated atherogenesis. PMID:29321372

  11. An Adiabatic Phase-Matching Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lemery, Francois [DESY; Floettmann, Klaus [DESY; Piot, Philippe [Northern Illinois U.; Kaertner, Franz X. [Hamburg U.; Assmann, Ralph [DESY

    2017-12-22

    We present a general concept to accelerate non-relativistic charged particles. Our concept employs an adiabatically-tapered dielectric-lined waveguide which supports accelerating phase velocities for synchronous acceleration. We propose an ansatz for the transient field equations, show it satisfies Maxwell's equations under an adiabatic approximation and find excellent agreement with a finite-difference time-domain computer simulation. The fields were implemented into the particle-tracking program {\\sc astra} and we present beam dynamics results for an accelerating field with a 1-mm-wavelength and peak electric field of 100~MV/m. The numerical simulations indicate that a $\\sim 200$-keV electron beam can be accelerated to an energy of $\\sim10$~MeV over $\\sim 10$~cm. The novel scheme is also found to form electron beams with parameters of interest to a wide range of applications including, e.g., future advanced accelerators, and ultra-fast electron diffraction.

  12. Kinetic theory in maximal-acceleration invariant phase space

    International Nuclear Information System (INIS)

    Brandt, H.E.

    1989-01-01

    A vanishing directional derivative of a scalar field along particle trajectories in maximal acceleration invariant phase space is identical in form to the ordinary covariant Vlasov equation in curved spacetime in the presence of both gravitational and nongravitational forces. A natural foundation is thereby provided for a covariant kinetic theory of particles in maximal-acceleration invariant phase space. (orig.)

  13. ACCELERATION PHASES OF A SOLAR FILAMENT DURING ITS ERUPTION

    International Nuclear Information System (INIS)

    Song, H. Q.; Chen, Y.; Fu, H.; Zhang, J.; Cheng, X.; LI, G.

    2015-01-01

    Filament eruptions often lead to coronal mass ejections (CMEs), which can affect critical technological systems in space and on the ground when they interact with the geo-magnetosphere at high speeds. Therefore, it is important to investigate the acceleration mechanisms of CMEs in solar/space physics. Based on observations and simulations, the resistive magnetic reconnection and the ideal instability of magnetic flux ropes have been proposed to accelerate CMEs. However, it remains uncertain whether both of them play a comparable role during a particular eruption. It has been extremely difficult to separate their contributions as they often work in a close time sequence during one fast acceleration phase. Here we report an intriguing filament eruption event, which shows two apparently separated fast acceleration phases and provides us an excellent opportunity to address the issue. Through analyzing the correlations between velocity (acceleration) and soft (hard) X-ray profiles, we suggest that the instability and magnetic reconnection make a major contribution during the first and second fast acceleration phases, respectively. Further, we find that both processes have a comparable contribution to the filament acceleration in this event

  14. PBFA [Particle Beam Fusion Accelerator] II: The pulsed power characterization phase

    International Nuclear Information System (INIS)

    Martin, T.H.; Turman, B.N.; Goldstein, S.A.

    1987-01-01

    The Particle Beam Fusion Accelerator II, PBFA II, is now the largest pulsed power device in operation. This paper summarizes its first year and a half of operation for the Department of Energy (DOE) Inertial Confinement Fusion (ICF) program. Thirty-six separate modules provide 72 output pulses that combine to form a 100 TW output pulse at the accelerator center. PBFA II was successfully test fired for the first time on December 11, 1985. This test completed the construction phase (Phase 1) within the expected schedule and budget. The accelerator checkout phase then started (Phase 2). The first priority during checkout was to bring the Phase 1 subsystems into full operation. The accelerator was first tested to determine overall system performance. Next, subsystems that were not performing adequately were modified. The accelerator is now being used for ion diode studies. 32 refs

  15. Nonlinear transport of accelerator beam phase space

    International Nuclear Information System (INIS)

    Xie Xi; Xia Jiawen

    1995-01-01

    Based on the any order analytical solution of accelerator beam dynamics, the general theory for nonlinear transport of accelerator beam phase space is developed by inverse transformation method. The method is general by itself, and hence can also be applied to the nonlinear transport of various dynamic systems in physics, chemistry and biology

  16. Muscle activation patterns in acceleration-based phases during reach-to-grasp movement.

    Science.gov (United States)

    Tokuda, Keisuke; Lee, Bumsuk; Shiihara, Yasufumi; Takahashi, Kazuhiro; Wada, Naoki; Shirakura, Kenji; Watanabe, Hideomi

    2016-11-01

    [Purpose] An earlier study divided reaching activity into characteristic phases based on hand velocity profiles. By synchronizing muscle activities and the acceleration profile, a phasing approach for reaching movement, based on hand acceleration profiles, was attempted in order to elucidate the roles of individual muscle activities in the different phases of the acceleration profile in reaching movements. [Subjects and Methods] Ten healthy volunteer subjects participated in this study. The aim was to electromyographically evaluate muscles around the shoulder, the upper trapezius, the anterior deltoid, the biceps brachii, and the triceps brachii, most of which have been used to evaluate arm motion, as well as the acceleration of the upper limb during simple reaching movement in the reach-to-grasp task. [Results] Analysis showed the kinematic trajectories of the acceleration during a simple biphasic profile of the reaching movement could be divided into four phases: increasing acceleration (IA), decreasing acceleration (DA), increasing deceleration (ID), and decreasing deceleration (DD). Muscles around the shoulder showed different activity patterns, which were closely associated with these acceleration phases. [Conclusion] These results suggest the important role of the four phases, derived from the acceleration trajectory, in the elucidation of the muscular mechanisms which regulate and coordinate the muscles around the shoulder in reaching movements.

  17. Imatinib mesylate in chronic myelogenous leukemia: a Congolese ...

    African Journals Online (AJOL)

    Major cytogenetic response was noticed in 87.18%. After a median follow up of 12 months, chronic myeloid leukemia had not progressed to the accelerated or blastic phase in an estimated 91.8% of patients and 86.6% were alive. Conclusion: Imatinib is effective in newly chronic phase chronic myeloid leukemia patient ...

  18. Microprocessor controller for phasing the accelerator

    International Nuclear Information System (INIS)

    Howry, S.K.; Wilmunder, A.R.

    1977-03-01

    A microprocessor controller is being developed to perform automatic phasing of the SLAC accelerator. It will replace the existing relay/analog boxes which are ten years old. The new system is all solid state except for the stepping motors that drive the phase shifters. A description is given of the components of the system, the control algorithm, microprocessor hardware and software design and development, and interaction with SLAC's computer control system

  19. Regional blood flow in the domestic fowl immediately following chronic acceleration

    International Nuclear Information System (INIS)

    Weidner, W.J.; Hoffman, L.F.; Clark, S.D.

    1982-01-01

    In order to examine the effects of chronic low G acceleration on blood flow distribution and cardiac output, chickens (N.10) were centrifuged at +2Gz for 30-61 d. Controls (N.12) were not centrifuged. The animals were anesthetized with sodium pentobarbital after removal from the centrifuge and surgically prepared in order to measure cardiac output and regional blood flows by the reference sample method with 85 Sr labeled microspheres (15 +/- 5 mum diam.). Both brachial arteries were cannulated to withdraw timed, paired blood samples at a known rate. The chest was opened and a cannula inserted into the left ventricle for administration of microspheres. Tissue samples were taken after completion of experimental procedures and their radioactivity was determined. The cardiac outputs in the two groups were not significantly different. Regional blood flows to the kidney, eyes, and skeletal muscle were significantly increased in the animals subjected to chronic +2Gz. While the mechanism by which these increases in blood flow occurred is not known, results indicate that chronic exposure to hyperdynamic gravitational fields can alter circulatory dynamics. We conclude that the cardiovascular system is directly involved in the process of adaptation to chronic positive acceleration

  20. Mathematical model of two-phase flow in accelerator channel

    Directory of Open Access Journals (Sweden)

    О.Ф. Нікулін

    2010-01-01

    Full Text Available  The problem of  two-phase flow composed of energy-carrier phase (Newtonian liquid and solid fine-dispersed phase (particles in counter jet mill accelerator channel is considered. The mathematical model bases goes on the supposition that the phases interact with each other like independent substances by means of aerodynamics’ forces in conditions of adiabatic flow. The mathematical model in the form of system of differential equations of order 11 is represented. Derivations of equations by base physical principles for cross-section-averaged quantity are produced. The mathematical model can be used for estimation of any kinematic and thermodynamic flow characteristics for purposely parameters optimization problem solving and transfer functions determination, that take place in  counter jet mill accelerator channel design.

  1. Omacetaxine Mepesuccinate for Chronic Myeloid Leukemia.

    Science.gov (United States)

    Rosshandler, Yasmin; Shen, Ann Q; Cortes, Jorge; Khoury, Hanna Jean

    2016-05-01

    Omacetaxine mepesuccinate is approved by the Food and Drug Administration in the United States for the treatment of chronic myeloid leukemia in chronic or accelerated phase resistant to two or more tyrosine kinase inhibitors. This review summarizes the mode of action, pharmacokinetics, efficacy and safety of omacetaxine mepesuccinate. Omacetaxine mepesuccinate has activity in chronic myeloid leukemia, especially in the chronic phase, regardless of the presence of ABL1 kinase domain mutations. Omacetaxine mepesuccinate has distinct but manageable adverse events profile. Omacetaxine mepesuccinate is a treatment option for a subset of patients with refractory chronic myeloid leukemia.

  2. Phase gradients in acceleration structures

    International Nuclear Information System (INIS)

    Decker, F.J.; Jobe, R.K.

    1990-05-01

    In linear accelerators with two or more bunches the beam loading of one bunch will influence the energy and energy spread the following bunches. This can be corrected by quickly changing the phase of a travelling wave structure, so that each bunch recieves a slightly different net phase. At the SLAC Linear Collider (SLC) three bunches, two (e + ,e - ) for the high energy collisions and one (e - -scavenger) for producing positrons should sit at different phases, due to their different tasks. The two e - -bunches are extracted from the damping ring at the same cycle time about 60 ns apart. Fast phase switching of the RF to the bunch length compressor in the Ring-To-Linac (RTL) section can produce the necessary advance of the scavenger bunch (about 6 degree in phase). This allows a low energy spread of this third bunch at the e + -production region at 2/3 of the linac length, while the other bunches are not influenced. The principles and possible other applications of this fast phase switching as using it for multi-bunches, as well as the experimental layout for the actual RTL compressor are presented

  3. Accelerated Adaptive MGS Phase Retrieval

    Science.gov (United States)

    Lam, Raymond K.; Ohara, Catherine M.; Green, Joseph J.; Bikkannavar, Siddarayappa A.; Basinger, Scott A.; Redding, David C.; Shi, Fang

    2011-01-01

    The Modified Gerchberg-Saxton (MGS) algorithm is an image-based wavefront-sensing method that can turn any science instrument focal plane into a wavefront sensor. MGS characterizes optical systems by estimating the wavefront errors in the exit pupil using only intensity images of a star or other point source of light. This innovative implementation of MGS significantly accelerates the MGS phase retrieval algorithm by using stream-processing hardware on conventional graphics cards. Stream processing is a relatively new, yet powerful, paradigm to allow parallel processing of certain applications that apply single instructions to multiple data (SIMD). These stream processors are designed specifically to support large-scale parallel computing on a single graphics chip. Computationally intensive algorithms, such as the Fast Fourier Transform (FFT), are particularly well suited for this computing environment. This high-speed version of MGS exploits commercially available hardware to accomplish the same objective in a fraction of the original time. The exploit involves performing matrix calculations in nVidia graphic cards. The graphical processor unit (GPU) is hardware that is specialized for computationally intensive, highly parallel computation. From the software perspective, a parallel programming model is used, called CUDA, to transparently scale multicore parallelism in hardware. This technology gives computationally intensive applications access to the processing power of the nVidia GPUs through a C/C++ programming interface. The AAMGS (Accelerated Adaptive MGS) software takes advantage of these advanced technologies, to accelerate the optical phase error characterization. With a single PC that contains four nVidia GTX-280 graphic cards, the new implementation can process four images simultaneously to produce a JWST (James Webb Space Telescope) wavefront measurement 60 times faster than the previous code.

  4. Methods of Phase and Power Control in Magnetron Transmitters for Superconducting Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Kazadevich, G. [MUONS Inc., Batavia; Johnson, R. [MUONS Inc., Batavia; Neubauer, M. [MUONS Inc., Batavia; Lebedev, V. [Fermilab; Schappert, W. [Fermilab; Yakovlev, V. [Fermilab

    2017-05-01

    Various methods of phase and power control in magnetron RF sources of superconducting accelerators intended for ADS-class projects were recently developed and studied with conventional 2.45 GHz, 1 kW, CW magnetrons operating in pulsed and CW regimes. Magnetron transmitters excited by a resonant (injection-locking) phasemodulated signal can provide phase and power control with the rates required for precise stabilization of phase and amplitude of the accelerating field in Superconducting RF (SRF) cavities of the intensity-frontier accelerators. An innovative technique that can significantly increase the magnetron transmitter efficiency at the widerange power control required for superconducting accelerators was developed and verified with the 2.45 GHz magnetrons operating in CW and pulsed regimes. High efficiency magnetron transmitters of this type can significantly reduce the capital and operation costs of the ADSclass accelerator projects.

  5. Dasatinib or imatinib in newly diagnosed chronic-phase chronic myeloid leukemia : 2-year follow-up from a randomized phase 3 trial (DASISION)

    NARCIS (Netherlands)

    Kantarjian, Hagop M.; Shah, Neil P.; Cortes, Jorge E.; Baccarani, Michele; Agarwal, Mohan B.; Soledad Undurraga, Maria; Wang, Jianxiang; Kassack Ipina, Juan Julio; Kim, Dong-Wook; Ogura, Michinori; Pavlovsky, Carolina; Junghanss, Christian; Milone, Jorge H.; Nicolini, Franck E.; Robak, Tadeusz; Van Droogenbroeck, Jan; Vellenga, Edo; Bradley-Garelik, M. Brigid; Zhu, Chao; Hochhaus, Andreas

    2012-01-01

    Dasatinib is a highly potent BCR-ABL inhibitor with established efficacy and safety in imatinib-resistant/-intolerant patients with chronic myeloid leukemia (CML). In the phase 3 DASISION trial, patients with newly diagnosed chronic-phase (CP) CML were randomized to receive dasatinib 100 mg (n =

  6. Accelerating large-scale phase-field simulations with GPU

    Directory of Open Access Journals (Sweden)

    Xiaoming Shi

    2017-10-01

    Full Text Available A new package for accelerating large-scale phase-field simulations was developed by using GPU based on the semi-implicit Fourier method. The package can solve a variety of equilibrium equations with different inhomogeneity including long-range elastic, magnetostatic, and electrostatic interactions. Through using specific algorithm in Compute Unified Device Architecture (CUDA, Fourier spectral iterative perturbation method was integrated in GPU package. The Allen-Cahn equation, Cahn-Hilliard equation, and phase-field model with long-range interaction were solved based on the algorithm running on GPU respectively to test the performance of the package. From the comparison of the calculation results between the solver executed in single CPU and the one on GPU, it was found that the speed on GPU is enormously elevated to 50 times faster. The present study therefore contributes to the acceleration of large-scale phase-field simulations and provides guidance for experiments to design large-scale functional devices.

  7. Gait Phases Recognition from Accelerations and Ground Reaction Forces: Application of Neural Networks

    Directory of Open Access Journals (Sweden)

    S. Rafajlović

    2009-06-01

    Full Text Available The goal of this study was to test the applicability of accelerometer as the sensor for assessment of the walking. We present here the comparison of gait phases detected from the data recorded by force sensing resistors mounted in the shoe insoles, non-processed acceleration and processed acceleration perpendicular to the direction of the foot. The gait phases in all three cases were detected by means of a neural network. The output from the neural network was the gait phase, while the inputs were data from the sensors. The results show that the errors were in the ranges: 30 ms (2.7% – force sensors; 150 ms (13.6% – nonprocessed acceleration, and 120 ms (11% – processed acceleration data. This result suggests that it is possible to use the accelerometer as the gait phase detector, however, with the knowledge that the gait phases are time shifted for about 100 ms with respect the neural network predicted times.

  8. Relationship between Acute Phase of Chronic Periodontitis and Meteorological Factors in the Maintenance Phase of Periodontal Treatment: A Pilot Study.

    Science.gov (United States)

    Takeuchi, Noriko; Ekuni, Daisuke; Tomofuji, Takaaki; Morita, Manabu

    2015-08-05

    The acute phase of chronic periodontitis may occur even in patients during supportive periodontal therapy. However, the details are not fully understood. Since the natural environment, including meteorology affects human health, we hypothesized that weather conditions may affect occurrence of acute phase of chronic periodontitis. The aim of this study was to investigate the relationship between weather conditions and acute phase of chronic periodontitis in patients under supportive periodontal therapy. Patients who were diagnosed with acute phase of chronic periodontitis under supportive periodontal therapy during 2011-2013 were selected for this study. We performed oral examinations and collected questionnaires and meteorological data. Of 369 patients who experienced acute phase of chronic periodontitis, 153 had acute phase of chronic periodontitis without direct-triggered episodes. When using the autoregressive integrated moving average model of time-series analysis, the independent covariant of maximum hourly range of barometric pressure, maximum hourly range of temperature, and maximum daily wind speed were significantly associated with occurrence of acute phase of chronic periodontitis (p chronic periodontitis.

  9. Laser-to-RF phase detection with femtosecond precision for remote reference phase stabilization in particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, Thorsten

    2017-05-15

    The operation of modern free-electron lasers (FELs) requires the synchronization of different accelerator subsystems with femtosecond precision. A pulsed optical synchronization system is for this reason operated at the Free-Electron Laser in Hamburg (FLASH) and it is under construction for the upcoming European X-ray Free-Electron Laser (XFEL). Laser pulses from the optical master oscillator are transmitted by timing stabilized optical fiberlinks to dedicated end stations along the accelerator. Devices which cannot operate with optical synchronization signals are instead conventionally synchronized with radio frequency (RF) reference signals. These signals are distributed in the accelerator by coaxial cables. Especially the low -level radio frequency (LLRF) system requires RF reference signals with femtosecond stability in order to meet nowadays femtosecond demands. Due to cable drifts and the length of the accelerators, this level of stability cannot be provided by conventional RF transport. A laser-to-RF (L2RF) phase detector has been invented, which allows to measure with femtosecond precision the relative phase between a phase stable optical pulse train from an optical fiberlink and an RF signal. The L2RF phase detector is based on an integrated MACH-ZEHNDER modulator (MZM) in which the phase error between both signals is encoded in an amplitude modulation of the optical pulse train. Different configurations, based on single output and dual output MZMs have been evaluated for different operation scenarios. A full mathematical representation of the chosen configuration has been derived. The impact of multiple error sources has been investigated. It has been proven that most error sources have only second or higher order influence on the detection principle which is a significant advantage over existing schemes. The invented L2RF phase detector is for example balanced and in its working point insensitive to power variations of the optical reference pulse train

  10. Laser-to-RF phase detection with femtosecond precision for remote reference phase stabilization in particle accelerators

    International Nuclear Information System (INIS)

    Lamb, Thorsten

    2017-05-01

    The operation of modern free-electron lasers (FELs) requires the synchronization of different accelerator subsystems with femtosecond precision. A pulsed optical synchronization system is for this reason operated at the Free-Electron Laser in Hamburg (FLASH) and it is under construction for the upcoming European X-ray Free-Electron Laser (XFEL). Laser pulses from the optical master oscillator are transmitted by timing stabilized optical fiberlinks to dedicated end stations along the accelerator. Devices which cannot operate with optical synchronization signals are instead conventionally synchronized with radio frequency (RF) reference signals. These signals are distributed in the accelerator by coaxial cables. Especially the low -level radio frequency (LLRF) system requires RF reference signals with femtosecond stability in order to meet nowadays femtosecond demands. Due to cable drifts and the length of the accelerators, this level of stability cannot be provided by conventional RF transport. A laser-to-RF (L2RF) phase detector has been invented, which allows to measure with femtosecond precision the relative phase between a phase stable optical pulse train from an optical fiberlink and an RF signal. The L2RF phase detector is based on an integrated MACH-ZEHNDER modulator (MZM) in which the phase error between both signals is encoded in an amplitude modulation of the optical pulse train. Different configurations, based on single output and dual output MZMs have been evaluated for different operation scenarios. A full mathematical representation of the chosen configuration has been derived. The impact of multiple error sources has been investigated. It has been proven that most error sources have only second or higher order influence on the detection principle which is a significant advantage over existing schemes. The invented L2RF phase detector is for example balanced and in its working point insensitive to power variations of the optical reference pulse train

  11. RF phase focusing in portable x-band, linear accelerators

    International Nuclear Information System (INIS)

    Miller, R.H.; Deruyter, H.; Fowkes, W.R.; Potter, J.M.; Schonberg, R.G.; Weaver, J.N.

    1985-01-01

    In order to minimize the size and weight of the x-ray or neutron source for a series of portable radiographic linear accelerators, the x-ray head was packaged separately from the rest of the system and consists of only the linac accelerating structure, electron gun, built-in target, collimator, ion pump and an RF window. All the driving electronics and cooling are connected to the x-ray head through flexible waveguide, cables, and waterlines. The x-ray head has been kept small and light weight by using the RF fields for radial focusing, as well as for longitudinal bunching and accelerating the beam. Thus, no external, bulky magnetic focusing devices are required. The RF focusing is accomplished by alternating the sign of the phase difference between the RF and the beam and by tapering from cavity to cavity the magnitude of the buncher field levels. The former requires choosing the right phase velocity taper (mix of less than vp = c cavities) and the latter requires the right sizing of the cavity to cavity coupling smiles (irises)

  12. RF phase focusing in portable X-band, linear accelerators

    International Nuclear Information System (INIS)

    Miller, R.H.; Deruyter, H.; Fowkes, W.R.; Potter, J.W.; Schonberg, R.G.; Weaver, J.W.

    1985-01-01

    In order to minimize the size and weight of the x-ray or neutron source for a series of portable radiographic linear accelerators, the x-ray head was packaged separately from the rest of the system and consists of only the linac accelerating structure, electron gun, built-in target, collimator, ion pump and an RF window. All the driving electronics and cooling are connected to the x-ray head through flexible waveguide, cables, and waterlines. The x-ray head has been kept small and light weight by using the RF fields for radial focusing, as well as for longitudinal bunching and accelerating the beam. Thus, no external, bulky magnetic focusing devices are required. The RF focusing is accomplished by alternating the sign of the phase difference between the RF and the beam and by tapering from cavity to cavity the magnitude of the buncher field levels. The former requires choosing the right phase velocity taper (mix of less than vp=c cavities) and the latter requires the right sizing of the cavity to cavity coupling smiles (irises)

  13. JAK2V617F mutation in chronic myeloid leukemia predicts early disease progression

    International Nuclear Information System (INIS)

    Pahore, Z.A.A.; Shamsi, T.S.; Taj, M.; Farzana, T.; Ansari, S.H.; Nadeem, M.; Ahmad, M.; Naz, A.

    2011-01-01

    Objective: To determine the association of JAK2V617F mutation along with BCR-ABL translocation or Philadelphia chromosome in chronic myeloid leukemia with early disease progression to advanced stages (accelerated phase or blast crisis) and poor outcome. Study Design: Case series. Place and Duration of Study: National Institute of Blood Diseases and Bone Marrow Transplantation, Karachi, from February 2008 to August 2009. Methodology: All the newly diagnosed cases of BCR-ABL or Philadelphia positive CML were tested for JAK2V617F mutation by Nested PCR. Demographic data, spleen size, hemoglobin levels, white blood cell and platelet counts were recorded. Independent sample t-test was used for age, haemoglobin level and spleen size. Fisher's exact test was applied to compare disease progression in JAK2V617F mutation positive and negative cases. Results: Out of 45 newly diagnosed cases of CML, 40 were in chronic phase, 01 in accelerated phase and 04 in blast crisis. JAK2V617F mutation was detected in 12 (26.7%) patients; 09 (22.5%) in chronic phase, none in accelerated phase and 03 (75%) in blast crisis. During a mean follow-up of 8 months, 03 patients in chronic phase transformed in blast crisis and 02 into accelerated phase. Overall 08 out of 11 (73%) JAK2V617F positive patients either had advanced disease or showed disease progression. Only 2 of 20 (10%) available patients, negative for the mutation, showed disease progression by transforming into blast crisis (p < 0.001). No statistically significant difference was seen in the age, spleen size, haemoglobin levels, white blood cells and platelets counts in JAK2V617F positive patients. Conclusion: JAK2V617F mutation was detected in 26.7% cases of chronic myeloid leukemia. A significant proportion of them showed early disease progression. (author)

  14. Beam Phase Detection for Proton Therapy Accelerators

    CERN Document Server

    Aminov, Bachtior; Getta, Markus; Kolesov, Sergej; Pupeter, Nico; Stephani, Thomas; Timmer, J

    2005-01-01

    The industrial application of proton cyclotrons for medical applications has become one of the important contributions of accelerator physics during the last years. This paper describes an advanced vector demodulating technique used for non-destructive measurements of beam intensity and beam phase over 360°. A computer controlled I/Q-based phase detector with a very large dynamic range of 70 dB permits the monitoring of beam intensity, phase and eventually energy for wide range of beam currents down to -130 dBm. In order to avoid interference from the fundamental cyclotron frequency the phase detection is performed at the second harmonic frequency. A digital low pass filter with adjustable bandwidth and steepness is implemented to improve accuracy. With a sensitivity of the capacitive pickup in the beam line of 30 nV per nA of proton beam current at 250 MeV, accurate phase and intensity measurements can be performed with beam currents down to 3.3 nA.

  15. The principle of phase stability and the accelerator program at Berkeley, 1945--1954

    International Nuclear Information System (INIS)

    Lofgren, E.J.

    1994-07-01

    The discovery of the Principle of Phase Stability by Vladimir Veksler and Edwin McMillian and the end of the war released a surge of accelerator activity at the Lawrence Berkeley Laboratory (then The University of California Radiation Laboratory). Six accelerators incorporating the Principle of Phase Stability were built in the period 1945--1954

  16. Phase and amplitude detection system for the Stanford Linear Accelerator

    International Nuclear Information System (INIS)

    Fox, J.D.; Schwarz, H.D.

    1983-01-01

    A computer controlled phase and amplitude detection system to measure and stabilize the rf power sources in the Stanford Linear Accelerator is described. This system measures the instantaneous phase and amplitude of a 1 microsecond 2856 MHz rf pulse and will be used for phase feedback control and for amplitude and phase jitter detection. This paper discusses the measurement system performance requirements for the operation of the Stanford Linear Collider, and the design and implementation of the phase and amplitude detection system. The fundamental software algorithms used in the measurement are described, as is the performance of the prototype phase and amplitude detector system

  17. Treatment of chronic myelogenous leukemia with interleukin-2: a phase II study in 21 patients.

    Science.gov (United States)

    Vey, N; Blaise, D; Lafage, M; Olive, D; Viens, P; Baume, D; Camerlo, J; Stoppa, A M; Gabus, R; Brandely, M; Hercend, T; Maraninchi, D

    1999-03-01

    We designed a phase II study to assess the activity of recombinant interleukin-2 (rIL-2) in patients with chronic myelogenous leukemia (CML). Study population included 11 patients in the chronic phase of CML (6 in hematologic remission and 5 with active disease), 6 patients in the accelerated phase, and 4 in blastic phase of CML. Patients received three 5-day cycles administrated every other week. rIL-2 was given as intravenous bolus infusions of 8 x 10(6) IU/m2 three times a day during cycle 1 and twice a day during cycles 2 and 3. Response to rIL-2 was assessed on day 45. No hematologic response was achieved in the patients with evaluable disease. One patient in hematologic remission with rIL-2 achieved a major response (from 72% to 9% Ph+ metaphases), and two patients had some degree of reduction of Ph+ metaphases. Responses were short-lived (< 6 months), but two of these three patients achieved a new cytogenetic response with interferon given post-rIL-2. A significant immune activation was achieved with rIL-2 including a marked increase in CD3+/CD25+ cells, CD56+ cells, and in natural killer/lymphokine activated killer cell cytotoxic activity. These results confirm preclinical studies, which showed that IL-2 has antileukemic activity in CML. However, the responses observed were short lived and restricted to a subgroup of patients with low disease burden. This invites further studies testing its impact in situations of minimal disease or in combination with other cytokines.

  18. Accelerated 4D phase contrast MRI in skeletal muscle contraction.

    Science.gov (United States)

    Mazzoli, Valentina; Gottwald, Lukas M; Peper, Eva S; Froeling, Martijn; Coolen, Bram F; Verdonschot, Nico; Sprengers, Andre M; van Ooij, Pim; Strijkers, Gustav J; Nederveen, Aart J

    2018-03-05

    3D time-resolved (4D) phase contrast MRI can be used to study muscle contraction. However, 3D coverage with sufficient spatiotemporal resolution can only be achieved by interleaved acquisitions during many repetitions of the motion task, resulting in long scan times. The aim of this study was to develop a compressed sensing accelerated 4D phase contrast MRI technique for quantification of velocities and strain rate of the muscles in the lower leg during active plantarflexion/dorsiflexion. Nine healthy volunteers were scanned during active dorsiflexion/plantarflexion task. For each volunteer, we acquired a reference scan, as well as 4 different accelerated scans (k-space undersampling factors: 3.14X, 4.09X, 4.89X, and 6.41X) obtained using Cartesian Poisson disk undersampling schemes. The data was reconstructed using a compressed sensing pipeline. For each scan, velocity and strain rate values were quantified in the gastrocnemius lateralis, gastrocnemius medialis, tibialis anterior, and soleus. No significant differences in velocity values were observed as a function acceleration factor in the investigated muscles. The strain rate calculation resulted in one positive (s + ) and one negative (s - ) eigenvalue, whereas the third eigenvalue (s 3 ) was consistently 0 for all the acquisitions. No significant differences were observed for the strain rate eigenvalues as a function of acceleration factor. Data undersampling combined with compressed sensing reconstruction allowed obtainment of time-resolved phase contrast acquisitions with 3D coverage and quantitative information comparable to the reference scan. The 3D sensitivity of the method can help in understanding the connection between muscle architecture and muscle function in future studies. © 2018 International Society for Magnetic Resonance in Medicine.

  19. Cytogenetic conversion following allogeneic bone marrow transplantation for advanced chronic myelogenous leukemia

    International Nuclear Information System (INIS)

    McGlave, P.B.; Miller, W.J.; Hurd, D.D.; Arthur, D.C.; Kim, T.

    1981-01-01

    We performed a pilot study to test the effectiveness of allogeneic bone marrow transplantation in the treatment of chronic myelogenous leukemia. Five patients in the advanced stages of chronic myelogenous leukemia (four in blast crisis, one in accelerated phase) with abnormal chromosomes underwent matched-sibling allogeneic bone marrow transplantation after preparation with busulfan, vincristine, cyclophosphamide, and fractionated total body irradiation. Engraftment and conversion to normal chromosome patterns after transplantation occurred in all five patients. None of the patients reverted to an abnormal chromosome pattern or demonstrated clinical or hematologic evidence of recurrent disease during the course of this study; however, longest survival from transplant was 248 days. Allogeneic bone marrow transplantation can eradicate the abnormal clone even in far advanced chronic myelogenous leukemia and can provide normal hematopoiesis. We suggest that clinical complications of chemotherapeutic toxicity and infection were responsible for the short survival in this group of patients, and that these complications could be decreased by performing transplantation in the chronic phase or early accelerated phase of the disease

  20. Design studies of heavy ion linear accelerators constructed of independently phased spiral resonators

    International Nuclear Information System (INIS)

    Stokes, R.H.; Armstrong, D.D.

    1975-01-01

    Preliminary design studies are reported for two linear accelerators for heavy ions. One accelerator is a high-intensity machine which would operate with 100 percent duty factor and would produce tin ions with 6.1 MeV/A. Alternatively, it could be operated under pulsed conditions with 25 percent duty factor and would then accelerate uranium ions to 8.1 MeV/A, tin ions to 10.5 MeV/A, and all lighter ions to higher velocities. It would be injected with a positive multicharge ion source and a 4-MV single-ended dc generator. Also, design studies are reported for small postaccelerator injected by a model FN tandem. Both accelerators use three-drift-tube spiral resonators operating at room temperature. Magnetic quadrupole singlets are placed between all resonators to provide radial focussing. Each resonator is independently phased according to the velocity of the ion to be accelerated. The ability to adjust the phase of each resonator permits variations in final energy and other beam properties with great flexibility. (U.S.)

  1. Azacytidine in combination with tyrosine kinase inhibitors induced durable responses in patients with advanced phase chronic myelogenous leukemia.

    Science.gov (United States)

    Ruggiu, Mathilde; Oberkampf, Florence; Ghez, David; Cony-Makhoul, Pascale; Beckeriche, Florence; Cano, Isabelle; Taksin, Anne L; Benbrahim, Omar; Ghez, Stéphanie; Farhat, Hassan; Rigaudeau, Sophie; de Gunzburg, Noémie; Lara, Diane; Terre, Christine; Raggueneau, Victoria; Garcia, Isabel; Spentchian, Marc; De Botton, Stéphane; Rousselot, Philippe

    2017-11-28

    Although the tyrosine kinase inhibitor (TKI) era has brought great improvement in outcome in chronic myelogenous leukemia (CML), prognosis of accelerated phase or myeloid blast crisis patients or of de novo Philadelphia chromosome-positive acute myeloid leukemia remains poor. We conducted a retrospective study on patients with advanced phase disease treated with a TKI and azacytidine. Sixteen patients were eligible. Median age was 64.9 years, the median number of previous therapies was 2.5 lines, and median follow-up was 23.1 months. Hematologic response (HR) rate was 81.3%. Median overall survival (OS), event free survival and relapse-free survival (RFS) were 31.5, 23.3, and 32.2 months, respectively. All except one patient were treated as out-patients after the first cycle. Five patients were bridged to allogenic hematopoietic stem cells transplant. The combination of a TKI and azacytidine is a safe and efficient regiment for patients with CML patients in advanced phases.

  2. Acceleration of a two-phase flow by boiling, (3)

    International Nuclear Information System (INIS)

    Mori, Yasuo; Hijikata, Kunio; Iwata, Shoichiro

    1976-01-01

    Acceleration of two-component, two-phase flow has been studied, and a method using the volume expansion by boiling for accelerating fluid has been investigated. In this study, the phenomena of atomizing and boiling were separated, and the liquid with low boiling point was injected into water at lower than the saturation temperature, and was atomized. Then, this was mixed with high temperature liquid and was boiled. The uniform buffle flow was produced, and the phenomena were observed with a high speed camera. The process of acceleration and the acceleration performance were compared with the results of theoretical analysis described in the second report. The experiment was carried out with liquid R113, and at first, the mechanism of atomizing was studied. The atomizing was caused when the relative velocity between R113 and water was more than 4 m/s irrespective of water velocity. The distribution of the diameter of fine liquid drops was almost normal distribution. When the fine drops of R113 were mixed with the high temperature water, bubbles were produced, and the production rate showed definite dependence on the degree of overheating. The flow of bubbles was uniform. However, some of R113 did not become bubbles. The efficiency of acceleration was 1.0 which was independent of the degree of overheating. A further problem is to reduce the quantity of the liquid which does not boil. (Kato, T.)

  3. Additional chromosome abnormalities in chronic myeloid leukemia

    Directory of Open Access Journals (Sweden)

    Hui-Hua Hsiao

    2011-02-01

    Full Text Available The Philadelphia (Ph chromosome and/or Breakpoint cluster region-Abelson leukemia virus oncogene transcript are unique markers for chronic myeloid leukemia (CML. However, CML demonstrates heterogeneous presentations and outcomes. We analyzed the cytogenetic and molecular results of CML patients to evaluate their correlation with clinical presentations and outcome. A total of 84 newly diagnosed CML patients were enrolled in the study. Patients were treated according to disease status. Bone marrow samples were obtained to perform cytogenetic and molecular studies. Clinical presentations, treatment courses, and survival were reviewed retrospectively. Among 84 patients, 72 had chronic phase and 12 had accelerated phase CML. Cytogenetic study showed 69 (82.1% with the classic Ph chromosome, 6 (7.2% with a variant Ph chromosome, and 9 (10.7% with additional chromosome abnormalities. Fifty-four (64.3% cases harbored b3a2 transcripts, 29 (34.5% had b2a2 transcript, and 1 had e19a2 transcript. There was no difference in clinical presentations between different cytogenetic and molecular groups; however, additional chromosome abnormalities were significantly associated with the accelerated phase. Imatinib therapy was an effective treatment, as measured by cytogenetic response, when administered as first- and second-line therapy in chronic phase patients. Survival analysis showed that old age, additional chromosome abnormalities, high Sokal score, and no cytogenetic response in second-line therapy had a significant poor impact (p<0.05. In conclusion, we presented the cytogenetic and molecular pattern of CML patients and demonstrated that the additional chromosome abnormality was associated with poor outcome.

  4. Exploring phase space using smartphone acceleration and rotation sensors simultaneously

    International Nuclear Information System (INIS)

    Monteiro, Martín; Cabeza, Cecilia; Martí, Arturo C

    2014-01-01

    A paradigmatic physical system as the physical pendulum is experimentally studied using the acceleration and rotation (gyroscope) sensors available on smartphones and other devices such as iPads and tablets. A smartphone is fixed to the outside of a bicycle wheel whose axis is kept horizontal and fixed. The compound system, wheel plus smartphone, defines a physical pendulum which can rotate, giving full turns in one direction, or oscillate about the equilibrium position (performing either small or large oscillations). Measurements of the radial and tangential acceleration and the angular velocity obtained with smartphone sensors allow a deep insight into the dynamics of the system to be gained. In addition, thanks to the simultaneous use of the acceleration and rotation sensors, trajectories in the phase space are directly obtained. The coherence of the measures obtained with the different sensors and by traditional methods is remarkable. Indeed, due to their low cost and increasing availability, smartphone sensors are valuable tools that can be used in most undergraduate laboratories. (paper)

  5. Exploring phase space using smartphone acceleration and rotation sensors simultaneously

    Science.gov (United States)

    Monteiro, Martín; Cabeza, Cecilia; Martí, Arturo C.

    2014-07-01

    A paradigmatic physical system as the physical pendulum is experimentally studied using the acceleration and rotation (gyroscope) sensors available on smartphones and other devices such as iPads and tablets. A smartphone is fixed to the outside of a bicycle wheel whose axis is kept horizontal and fixed. The compound system, wheel plus smartphone, defines a physical pendulum which can rotate, giving full turns in one direction, or oscillate about the equilibrium position (performing either small or large oscillations). Measurements of the radial and tangential acceleration and the angular velocity obtained with smartphone sensors allow a deep insight into the dynamics of the system to be gained. In addition, thanks to the simultaneous use of the acceleration and rotation sensors, trajectories in the phase space are directly obtained. The coherence of the measures obtained with the different sensors and by traditional methods is remarkable. Indeed, due to their low cost and increasing availability, smartphone sensors are valuable tools that can be used in most undergraduate laboratories.

  6. Impaired theta phase-resetting underlying auditory N1 suppression in chronic alcoholism.

    Science.gov (United States)

    Fuentemilla, Lluis; Marco-Pallarés, Josep; Gual, Antoni; Escera, Carles; Polo, Maria Dolores; Grau, Carles

    2009-02-18

    It has been suggested that chronic alcoholism may lead to altered neural mechanisms related to inhibitory processes. Here, we studied auditory N1 suppression phenomena (i.e. amplitude reduction with repetitive stimuli) in chronic alcoholic patients as an early-stage information-processing brain function involving inhibition by the analysis of the N1 event-related potential and time-frequency computation (spectral power and phase-resetting). Our results showed enhanced neural theta oscillatory phase-resetting underlying N1 generation in suppressed N1 event-related potential. The present findings suggest that chronic alcoholism alters neural oscillatory synchrony dynamics at very early stages of information processing.

  7. Phase velocity of nonlinear plasma waves in the laser beat-wave accelerator

    International Nuclear Information System (INIS)

    Spence, W.L.

    1985-01-01

    The suggested plasma-laser accelerator is an attempt to achieve a very high energy gradient by resonantly exciting a longitudinal wave traveling at close to the speed of light in cold plasma by means of the beat-wave generated by the transverse fields in two laser beams. Previous calculations to all orders in v/sub z/ have been done essentially from the laboratory frame point of view and have treated the plasma wave as having sharply defined phase velocity equal to the speed of light. However a high energy particle beam undergoing acceleration sees the plasma wave from a nearly light-like frame of reference and hence is very sensitive to small deviations in its phase velocity. Here the authors introduce a calculational scheme that includes all orders in v/sub z/ and in the plasma density, and additionally takes into account the influence of plasma nonlinearities on the wave's phase velocity. The main assumption is that the laser frequencies are very large compared to the plasma frequency - under which they are able to in essence formally sum up all orders of forward Raman scattering. They find that the nonlinear plasma wave does not have simply a single phase velocity - it is really a superposition of many - but that the beat-wave which drives it is usefully described by a non-local effective phase velocity function

  8. Prototype phase and amplitude feedback-control systems for the FMIT accelerator

    International Nuclear Information System (INIS)

    Fazio, M.V.; Patton, R.D.

    1983-01-01

    The phase and amplitude feedback-control systems for the Fusion Materials irradiation Test (FMIT) accelerator have been successfully prototyped and tested. The testing was performed at low power with two 100-W rf systems driving a high-Q resonant cavity at 80 MHz. The control systems can maintain the cavity field amplitude to within +-1% and the phase to within +-1 0 of the set-point values. When there are multiple rf systems independently driving a resonant cavity through individual drive loops, amplitude matching and proper phasing between the outputs of each rf system are essential for proper system operation. Experimental results are presented

  9. Family needs in the chronic phase after severe brain injury in Denmark

    DEFF Research Database (Denmark)

    Doser, Karoline; Norup, Anne

    2014-01-01

    Abstract Objective: This preliminary study aimed at investigating (1) changes in the status of family members between time of injury and follow-up in the chronic phase and (2) the most important needs within the family in the chronic phase and whether the needs were perceived as met. Participants......: The sample comprised 42 relatives (76% female, mean age = 53 years) of patients with severe brain injury, who had received intensive sub-acute rehabilitation. The relatives were contacted in the chronic phase after brain injury. Outcome measure: A set of questions about demographics and time spent caregiving...... for the patient was completed. The relatives completed the revised version of the Family Needs Questionnaire, a questionnaire consisting of 37 items related to different needs following brain injury. Results: Significant changes in status were found in employment (z = -3.464, p = 0.001) and co-habitation (z = -3...

  10. Accelerated safety analyses - structural analyses Phase I - structural sensitivity evaluation of single- and double-shell waste storage tanks

    International Nuclear Information System (INIS)

    Becker, D.L.

    1994-11-01

    Accelerated Safety Analyses - Phase I (ASA-Phase I) have been conducted to assess the appropriateness of existing tank farm operational controls and/or limits as now stipulated in the Operational Safety Requirements (OSRs) and Operating Specification Documents, and to establish a technical basis for the waste tank operating safety envelope. Structural sensitivity analyses were performed to assess the response of the different waste tank configurations to variations in loading conditions, uncertainties in loading parameters, and uncertainties in material characteristics. Extensive documentation of the sensitivity analyses conducted and results obtained are provided in the detailed ASA-Phase I report, Structural Sensitivity Evaluation of Single- and Double-Shell Waste Tanks for Accelerated Safety Analysis - Phase I. This document provides a summary of the accelerated safety analyses sensitivity evaluations and the resulting findings

  11. Firstline treatment for chronic phase chronic myeloid leukemia patients should be based on a holistic approach.

    Science.gov (United States)

    Breccia, Massimo; Alimena, Giuliana

    2015-02-01

    New selective and more potent drugs for the cure of chronic phase chronic myeloid leukemia patients are now available: physicians in some countries must decide the best option, selecting one of the drugs available. What the main prognostic factors are in order to make this selection remains a matter of discussion. Introducing a 'holistic approach' for the first time in chronic myeloid leukemia, as practiced in other diseases, and looking at the patient in a complete picture, considering several variables, such as comorbidities, age, concomitant drugs, lifestyle and patient expectations, may be of help to understand, patient by patient, the best therapeutic strategy.

  12. Management of Advanced-Phase Chronic Myelogenous Leukemia.

    Science.gov (United States)

    Radich, Jerald P

    2016-05-01

    Chronic myelogenous leukemia represents the poster child of successful precision medicine in cancer, with amazing survival results achieved with targeted tyrosine kinase inhibitors (TKIs) in many patients with chronic-phase disease. Unfortunately, however, this good news has not extended to patients in blast crisis, for whom survival has not clearly been improved with TKIs. During his presentation at the NCCN 21st Annual Conference, Jerald P. Radich, MD, briefly explored the biology behind advanced-stage disease and several of the molecular findings in disease progression. He also reviewed some of the therapeutic options in advanced disease, emphasizing that transplantation, although fraught with some difficulties, offers the best long-term prognosis for patients in blast crisis. Copyright © 2016 by the National Comprehensive Cancer Network.

  13. Correlated histogram representation of Monte Carlo derived medical accelerator photon-output phase space

    Science.gov (United States)

    Schach Von Wittenau, Alexis E.

    2003-01-01

    A method is provided to represent the calculated phase space of photons emanating from medical accelerators used in photon teletherapy. The method reproduces the energy distributions and trajectories of the photons originating in the bremsstrahlung target and of photons scattered by components within the accelerator head. The method reproduces the energy and directional information from sources up to several centimeters in radial extent, so it is expected to generalize well to accelerators made by different manufacturers. The method is computationally both fast and efficient overall sampling efficiency of 80% or higher for most field sizes. The computational cost is independent of the number of beams used in the treatment plan.

  14. Vecksler-Macmillan phase stability for neutral atoms accelerated by a laser beam

    Science.gov (United States)

    Mel'nikov, I. V.; Haus, J. W.; Kazansky, P. G.

    2003-05-01

    We use a Fokker-Planck equation to study the phenomenon of accelerating a neutral atom bunch by a chirped optical beam. This method enables us to obtain a semi-analytical solution to the problem in which a wide range of parameters can be studied. In addition it provides a simple physical interpretation where the problem is reduced to an analogous problem of charged particles accelerators, that is, the Vecksler-Macmillan principle of phase stability. A possible experimental scenario is suggested, which uses a photonic crystal fiber as the guiding medium.

  15. Differences in hamstring activation characteristics between the acceleration and maximum-speed phases of sprinting.

    Science.gov (United States)

    Higashihara, Ayako; Nagano, Yasuharu; Ono, Takashi; Fukubayashi, Toru

    2018-06-01

    This study aimed to investigate activation characteristics of the biceps femoris long head (BFlh) and semitendinosus (ST) muscles during the acceleration and maximum-speed phases of sprinting. Lower-extremity kinematics and electromyographic (EMG) activities of the BFlh and ST muscles were examined during the acceleration sprint and maximum-speed sprint in 13 male sprinters during an overground sprinting. Differences in hamstring activation during each divided phases and in the hip and knee joint angles and torques at each time point of the sprinting gait cycle were determined between two sprints. During the early stance of the acceleration sprint, the hip extension torque was significantly greater than during the maximum-speed sprint, and the relative EMG activation of the BFlh muscle was significantly higher than that of the ST muscle. During the late stance and terminal mid-swing of maximum-speed sprint, the knee was more extended and a higher knee flexion moment was observed compared to the acceleration sprint, and the ST muscle showed higher activation than that of the BFlh. These results indicate that the functional demands of the medial and lateral hamstring muscles differ between two different sprint performances.

  16. Average accelerator simulation Truebeam using phase space in IAEA format

    International Nuclear Information System (INIS)

    Santana, Emico Ferreira; Milian, Felix Mas; Paixao, Paulo Oliveira; Costa, Raranna Alves da; Velasco, Fermin Garcia

    2015-01-01

    In this paper is used a computational code of radiation transport simulation based on Monte Carlo technique, in order to model a linear accelerator of treatment by Radiotherapy. This work is the initial step of future proposals which aim to study several treatment of patient by Radiotherapy, employing computational modeling in cooperation with the institutions UESC, IPEN, UFRJ e COI. The Chosen simulation code is GATE/Geant4. The average accelerator is TrueBeam of Varian Company. The geometric modeling was based in technical manuals, and radiation sources on the phase space for photons, provided by manufacturer in the IAEA (International Atomic Energy Agency) format. The simulations were carried out in equal conditions to experimental measurements. Were studied photons beams of 6MV, with 10 per 10 cm of field, focusing on a water phantom. For validation were compared dose curves in depth, lateral profiles in different depths of the simulated results and experimental data. The final modeling of this accelerator will be used in future works involving treatments and real patients. (author)

  17. First phase plan for experimental study of heavy-ion inertial fusion accelerator

    International Nuclear Information System (INIS)

    Hattori, Toshiyuki; Okamura, Masahiro; Oguri, Yoshiyuki; Aida, Toshihiro; Takeuchi, Kouichi; Sasa, Kimikazu; Itoh, Takashi; Okada, Masashi; Takahashi, Yousuke; Ishii, Yasuyuki.

    1993-01-01

    We propose the basic experiment plan of driver for heavy-ion inertial fusion by heavy-ion linac [1-3] system and the heavy-ion cooler synchrotron. As the first phase of planning, we will improve old heavy-ion accelerator system that accelerate small intensity around Cl ion with charge to mass ratio of 1/4 up to 2.4 MeV/amu. The injector of the system will exchange from the 1.6 MV Peletron Tandem accelerator to an RFQ type linac with an ECR heavy-ion source. According to building up the power sources of RF and focusing magnet, then it is able to accelerate intense around Xe ion with charge to mass ratio of 1/6 up to 2.4 MeV/amu. At the next stage of it, we will construct a heavy-ion cooler synchrotron having magneticrigidity of 3 or 6 Tm and begin to study about HIF driver. (author)

  18. Dasatinib in Pediatric Patients With Chronic Myeloid Leukemia in Chronic Phase: Results From a Phase II Trial.

    Science.gov (United States)

    Gore, Lia; Kearns, Pamela R; de Martino, Maria Lucia; Lee; De Souza, Carmino Antonio; Bertrand, Yves; Hijiya, Nobuko; Stork, Linda C; Chung, Nack-Gyun; Cardos, Rocio Cardenas; Saikia, Tapan; Fagioli, Franca; Seo, Jong Jin; Landman-Parker, Judith; Lancaster, Donna; Place, Andrew E; Rabin, Karen R; Sacchi, Mariana; Swanink, Rene; Zwaan, C Michel

    2018-05-01

    Purpose Safe, effective treatments are needed for pediatric patients with chronic myeloid leukemia in chronic phase (CML-CP). Dasatinib is approved for treatment of adults and children with CML-CP. A phase I study determined suitable dosing for children with Philadelphia chromosome-positive (Ph+) leukemias. Methods CA180-226/NCT00777036 is a phase II, open-label, nonrandomized prospective trial of patients 30% for imatinib-resistant/intolerant patients and complete cytogenetic response (CCyR) > 55% for newly diagnosed patients were of clinical interest. Results Of 113 patients with CML-CP, 14 (48%) who were imatinib-resistant/intolerant and 61 (73%) who were newly diagnosed remained on treatment at time of analysis. Major cytogenetic response > 30% was reached by 3 months in the imatinib-resistant/intolerant group and CCyR > 55% was reached by 6 months in the newly diagnosed CML-CP group. CCyR and major molecular response by 12 months, respectively, were 76% and 41% in the imatinib-resistant/intolerant group and 92% and 52% in newly diagnosed CML-CP group. Progression-free survival by 48 months was 78% and 93% in the imatinib-resistant/intolerant and newly diagnosed CML-CP groups, respectively. No dasatinib-related pleural or pericardial effusion, pulmonary edema, or pulmonary arterial hypertension were reported. Bone growth and development events were reported in 4% of patients. Conclusion In the largest prospective trial to date in children with CML-CP, we demonstrate that dasatinib is a safe, effective treatment of pediatric CML-CP. Target responses to first- or second-line dasatinib were met early, and deep molecular responses were observed. Safety of dasatinib in pediatric patients was similar to that observed in adults; however, no cases of pleural or pericardial effusion or pulmonary arterial hypertension were reported.

  19. All-Optical Quasi-Phase Matching for Laser Electron Acceleration

    Science.gov (United States)

    2016-06-01

    center wavelength of 800 nm and FWHM bandwidth of ∼30 nm. The laser beam was split into three by two beam splitters ; the first reflected beam served...Figure 4.6(e) shows a small parabolic phase which is due to small chirp caused by a beam splitter in the system. Figures 4.6(d) and 4.6(f) show curves...basis for implementation of this laser acceleration technique. A deterministic test particle simulation has been developed to facilitate the design of the

  20. Virtual Accelerator for Accelerator Optics Improvement

    CERN Document Server

    Yan Yi Ton; Decker, Franz Josef; Ecklund, Stanley; Irwin, John; Seeman, John; Sullivan, Michael K; Turner, J L; Wienands, Ulrich

    2005-01-01

    Through determination of all quadrupole strengths and sextupole feed-downs by fitting quantities derivable from precision orbit measurement, one can establish a virtual accelerator that matches the real accelerator optics. These quantities (the phase advances, the Green's functions, and the coupling eigen-plane ellipses tilt angles and axis ratios) are obtained by analyzing turn-by-turn Beam Position Monitor (BPM) data with a model-independent analysis (MIA). Instead of trying to identify magnet errors, a limited number of quadrupoles are chosen for optimized strength adjustment to improve the virtual accelerator optics and then applied to the real accelerator accordingly. These processes have been successfully applied to PEP-II rings for beta beating fixes, phase and working tune adjustments, and linear coupling reduction to improve PEP-II luminosity.

  1. Radotinib and its clinical potential in chronic-phase chronic myeloid leukemia patients: an update.

    Science.gov (United States)

    Eskazan, Ahmet Emre; Keskin, Dilek

    2017-09-01

    Although imatinib has dramatically improved major outcomes in patients with chronic myeloid leukemia (CML), there are newer tyrosine kinase inhibitors (TKIs) approved worldwide for the treatment of resistant cases, and two second-generation TKIs (dasatinib, nilotinib) are approved in some nations for treating patients in the upfront setting. Radotinib (IY5511HCL, Supect® ) is a novel and selective second-generation BCR-ABL1 TKI, which is currently approved in Korea for the treatment of patients with CML both in the upfront and salvage settings. This review mainly focuses on the clinical potential of radotinib in patients with CML in chronic phase in terms of efficacy and safety.

  2. Accelerated three-dimensional cine phase contrast imaging using randomly undersampled echo planar imaging with compressed sensing reconstruction.

    Science.gov (United States)

    Basha, Tamer A; Akçakaya, Mehmet; Goddu, Beth; Berg, Sophie; Nezafat, Reza

    2015-01-01

    The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing (CS) reconstruction. The undersampled data were then reconstructed using low-dimensional structural self-learning and thresholding (LOST). 3D phase contrast MRI was acquired in 11 healthy adults using an overall acceleration of 7 (EPI factor of 3 and CS rate of 3). For comparison, a single two-dimensional (2D) cine phase contrast scan was also performed with sensitivity encoding (SENSE) rate 2 and approximately at the level of the pulmonary artery bifurcation. The stroke volume and mean velocity in both the ascending and descending aorta were measured and compared between two sequences using Bland-Altman plots. An average scan time of 3 min and 30 s, corresponding to an acceleration rate of 7, was achieved for 3D cine phase contrast scan with one direction flow encoding, voxel size of 2 × 2 × 3 mm(3) , foot-head coverage of 6 cm and temporal resolution of 30 ms. The mean velocity and stroke volume in both the ascending and descending aorta were statistically equivalent between the proposed 3D sequence and the standard 2D cine phase contrast sequence. The combination of EPI with a randomly undersampled 3D k-space sampling sequence using LOST reconstruction allows a seven-fold reduction in scan time of 3D cine phase contrast MRI without compromising blood flow quantification. Copyright © 2014 John Wiley & Sons, Ltd.

  3. The BCR-ABLT315I mutation compromises survival in chronic phase chronic myelogenous leukemia patients resistant to tyrosine kinase inhibitors, in a matched pair analysis

    DEFF Research Database (Denmark)

    Nicolini, Franck E; Ibrahim, Amr R; Soverini, Simona

    2013-01-01

    The BCR-ABL T315I mutation confers resistance to currently licensed tyrosine kinase inhibitors in chronic myelogenous leukemia. However, the impact of this mutation on survival in early stages of disease, in chronic phase, has never been detailed. Using matched pair analysis, a cohort of 64...... patients with chronic phase chronic myelogenous leukemia harboring a T315I mutation and resistant to imatinib mesylate was compared to a similar cohort of 53 chronic phase patients resistant to imatinib, but with no detectable T315I mutation, in the pre-ponatinib era. These patients were matched according...... to age at diagnosis, interval between disease diagnosis and start of imatinib treatment, and duration of imatinib therapy. Kaplan-Meier survival analyses demonstrated the significant negative impact of the presence of the T315I mutation on overall survival (since imatinib-resistance: 48.4 months for T315...

  4. Chronic stress accelerates the development of endometriosis in mouse through adrenergic receptor β2.

    Science.gov (United States)

    Long, Qiqi; Liu, Xishi; Qi, Qiuming; Guo, Sun-Wei

    2016-11-01

    Does chronic stress in mice accelerate the development of endometriosis, and, if so, through what mechanism? Exposure to chronic stress accelerates the development of endometriosis and exacerbates the endometriosis-associated generalized hyperalgesia, most likely through activation of the adrenoceptor β2 (ADRB2) and cAMP responsive element-binding protein (CREB). Women with endometriosis tend to have higher levels of psychological stress, which is known to impact negatively on health in general and to promote tumor growth and metastasis in particular. Exposure to chronic stress before and after the induction of endometriosis is reported to increase lesion sizes in rodents, but it is unclear whether adrenoceptors are involved or not in the stress-promoted development of endometriosis. Three independent, prospective, randomized mouse experimentations. A total of 184 virgin female Balb/C mice were used. In Experiment 1, the mice were randomly divided into four groups: the control group, which received no stress; the before, after and both groups, which received immobilization stress before, after and both before and after the induction of endometriosis, respectively. In Experiment 2, mice were randomly divided into four groups one day after the induction of endometriosis: phosphate buffer saline (PBS) and propranolol (PROP) groups, which received the mini-pump containing, respectively, PBS only and propranolol (a non-selective ADRB antagonist) but no stress, STR+PROP and STR+PBS groups, which received stress and the mini-pump containing, respectively, propranolol and PBS. The immobilization stress started after the insertion of mini-pumps. In Experiment 3, mice were induced with endometriosis. Three days after the induction, they were randomly divided into four groups: control, ADRAa, ADRB2a, and ADRBa, which received the mini-pump containing solution only, metaraminol (a non-specific α adrenoceptor agonist), tebutaline (a specific ADRB2 agonist), or isoproterenol

  5. Coherent-phase or random-phase acceleration of electron beams in solar flares

    Science.gov (United States)

    Aschwanden, Markus J.; Benz, Arnold O.; Montello, Maria L.

    1994-01-01

    Time structures of electron beam signatures at radio wavelengths are investigated to probe correlated versus random behavior in solar flares. In particular we address the issue whether acceleration and injection of electron beams is coherently modulated by a single source, or whether the injection is driven by a stochastic (possibly spatially fragmented) process. We analyze a total of approximately = 6000 type III bursts observed by Ikarus (Zurich) in the frequency range of 100-500 MHz, during 359 solar flares with simultaneous greater than or = 25 keV hard X-ray emission, in the years 1890-1983. In 155 flares we find a total of 260 continuous type III groups, with an average number of 13 +/- 9 bursts per group, a mean duration of D = 12 +/- 14 s, a mean period of P = 2.0 +/- 1.2 s, with the highest burst rate at a frequency of nu = 310 +/- 120 MHz. Pulse periods have been measured between 0.5 and 10 s, and can be described by an exponential distribution, i.e., N(P) varies as e (exp -P/1.0s). The period shows a frequency dependence of P(nu)=46(exp-0.6)(sub MHz)s for different flares, but is invariant during a particular flare. We measure the mean period P and its standard deviation sigma (sub p) in each type III group, and quantify the degree of periodicity (or phase-coherence) by the dimensionless parameter sigma (sub p)P. The representative sample of 260 type III burst groups shows a mean periodicity of sigma (sub p/P) = 0.37 +/- 0.12, while Monte Carlo simulations of an equivalent set of truly random time series show a distinctly different value of sigma (sub p)P = 0.93 +/- 0.26. This result indicates that the injection of electron beams is coherently modulated by a particle acceleration source which is either compact or has a global organization on a timescale of seconds, in contrast to an incoherent acceleration source, which is stochastic either in time or space. We discuss the constraints on the size of the acceleration region resulting from electron beam

  6. Two-phase flow dynamics in a model steam generator under vertical acceleration oscillation field

    International Nuclear Information System (INIS)

    Ishida, T.; Teshima, N.; Sakurai, S.

    1992-01-01

    The influence of periodically varying acceleration on hydrodynamic response has been studied experimentally using an experimental rig which models a marine reactor subject to vertical motion. The effect on the primary loop is small, but the effect on the secondary loop is large. The variables of the secondary loop, such as circulation flow rate and water level, oscillate with acceleration. The variation of gains in frequency response is analysed. The variations of flow in the secondary loop and in the downcome water level, increase in proportion to the acceleration. The effect of the flow resistance in the secondary loop on the two-phase flow dynamics is clarified. (7 figures) (Author)

  7. Gas-phase hydrosilylation of cyclohexene in an experimental radiation-chemical accelerator apparatus

    International Nuclear Information System (INIS)

    Pecherkin, A.S.; Sidorov, V.I.; Chernyshev, E.A.

    1992-01-01

    A process for the synthesis of methylcyclohexyldichlorosilane (a basic monomer for the production of organosilicon photoresists) has been investigated and perfected on an experimental apparatus with an ELV-2 electron accelerator; this synthesis involves gas-phase radiation-induced hydrosilylation of cyclohexene by methyldichlorosilane. Basic characteristics of the yield of the desired product under static conditions were determined. With the help of experiments on the synthesis of methylcyclohexyldichlorosilane in a flow- through mode, the technical features of the process of radiation-chemical hydrosilylation of cyclohexene on an accelerator apparatus were determined and studied, the optimal conditions for the synthesis were determined, and an experimental batch of the desired product was produced

  8. Phase-space holes due to electron and ion beams accelerated by a current-driven potential ramp

    Directory of Open Access Journals (Sweden)

    M. V. Goldman

    2003-01-01

    Full Text Available One-dimensional open-boundary simulations have been carried out in a current-carrying plasma seeded with a neutral density depression and with no initial electric field. These simulations show the development of a variety of nonlinear localized electric field structures: double layers (unipolar localized fields, fast electron phase-space holes (bipolar fields moving in the direction of electrons accelerated by the double layer and trains of slow alternating electron and ion phase-space holes (wave-like fields moving in the direction of ions accelerated by the double layer. The principal new result in this paper is to show by means of a linear stability analysis that the slow-moving trains of electron and ion holes are likely to be the result of saturation via trapping of a kinetic-Buneman instability driven by the interaction of accelerated ions with unaccelerated electrons.

  9. Convergence acceleration of two-phase flow calculations in FLICA-4. A thermal-hydraulic 3D computer code

    International Nuclear Information System (INIS)

    Toumi, I.

    1995-01-01

    Time requirements for 3D two-phase flow steady state calculations are generally long. Usually, numerical methods for steady state problems are iterative methods consisting in time-like methods that are marched to a steady state. Based on the eigenvalue spectrum of the iteration matrix for various flow configuration, two convergence acceleration techniques are discussed; over-relaxation and eigenvalue annihilation. This methods were applied to accelerate the convergence of three dimensional steady state two-phase flow calculations within the FLICA-4 computer code. These acceleration methods are easy to implement and no extra computer memory is required. Successful results are presented for various test problems and a saving of 30 to 50 % in CPU time have been achieved. (author). 10 refs., 4 figs

  10. Peculiarities of laser phase behavior associated with the accelerated electron in a chirped laser pulse

    International Nuclear Information System (INIS)

    Song, Q.; Wu, X. Y.; Wang, J. X.; Kawata, S.; Wang, P. X.

    2014-01-01

    In this paper, we qualitatively analyzed peculiarities of laser phase behavior associated with the accelerated electron in a chirped laser pulse. We unveiled the relationship between the changes in the orientation of the electron trajectory and the cusps in magnitude of the phase velocity of the optical field along the electron trajectory in a chirped laser pulse. We also explained how the chirp effect induced the singular point of the phase velocity. Finally, we discussed the phase velocity and phase witnessed by the electron in the particle's moving instantaneous frame

  11. Impedance-based analysis and study of phase sensitivity in slow-wave two-beam accelerators

    International Nuclear Information System (INIS)

    Wurtele, J.S.; Whittum, D.H.; Sessler, A.M.

    1992-06-01

    This paper presents a new formalism which makes the analysis and understanding of both the relativistic klystron (RK) and the standing-wave free-electron laser (SWFEL) two-beam accelerator (TBA) available to a wide audience of accelerator physicists. A ''coupling impedance'' for both the RK and SWFEWL is introduced, which can include realistic cavity features, such as beam and vacuum ports, in a simple manner. The RK and SWFEL macroparticle equations, which govern the energy and phase evolution of successive bunches in the beam, are of identical form, differing only by multiplicative factors. Expressions are derived for the phase and amplitude sensitivities of the TBA schemes to errors (shot-to-shot jitter) in current and energy. The analysis allows, for the first time, relative comparisons of the RK and the SWFEL TBAs

  12. Harnessing collaborative technology to accelerate achievement of chronic disease management objectives for Canada.

    Science.gov (United States)

    Thompson, Leslee J; Healey, Lindsay; Falk, Will

    2007-01-01

    Morgan and colleagues put forth a call to action for the transformation of the Canadian healthcare system through the adoption of a national chronic disease prevention and management (CDPM) strategy. They offer examples of best practices and national solutions including investment in clinical information technologies to help support improved care and outcomes. Although we acknowledge that the authors propose CDPM solutions that are headed in the right direction, more rapid deployment of solutions that harness the potential of advanced collaborative technologies is required. We provide examples of how technologies that exist today can help to accelerate the achievement of some key CDPM objectives.

  13. Accelerating Energy Efficiency in Indian Data Centers. Final Report for Phase I Activities

    Energy Technology Data Exchange (ETDEWEB)

    Ganguly, Suprotim [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Raje, Sanyukta [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kumar, Satish [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sartor, Dale [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Greenberg, Steve [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-01-01

    This report documents Phase 1 of the “Accelerating Energy Efficiency in Indian Data Centers” initiative to support the development of an energy efficiency policy framework for Indian data centers. The initiative is being led by the Confederation of Indian Industry (CII), in collaboration with Lawrence Berkeley National Laboratory (LBNL)-U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy, and under the guidance of Bureau of Energy Efficiency (BEE). It is also part of the larger Power and Energy Efficiency Working Group of the US-India Bilateral Energy Dialogue. The initiative consists of two phases: Phase 1 (November 2014 – September 2015) and Phase 2 (October 2015 – September 2016).

  14. Measurement of beam phase at FLASH using HOMs in accelerating cavities

    CERN Document Server

    Shi, Lianliang; Jones, Roger M; Joshi, Nirav

    2017-01-01

    The beam phase relative to the accelerating field is of vital importance for the quality of photon beams produced in modern Free Electron Lasers based on superconducting cavities. Normally, the phase is determined by detecting the transient field induced by the beam. In this way the phase of each cavity is checked and adjusted typically every few months. In this paper, we present an on-line method of beam phase determination, based on higher order modes (HOMs) excited in the 2nd monopole band by the beam inside these cavities. A circuit model of this HOM band is also presented. Various effects on the resolution have been studied. The results indicate that the resolution is strongly dependent on the signal to noise ratio and the sampling rate. Preliminary experimental results, based on a broadband setup, reveal a resolution of ca. 0.1° RMS. These are in good agreement with simulation results. The work will pave the way for a dedicated system of beam phase monitoring, which is under development for the Europea...

  15. Chronic stress accelerates ligature-induced periodontitis by suppressing glucocorticoid receptor-α signaling.

    Science.gov (United States)

    Lu, Huaixiu; Xu, Minguang; Wang, Feng; Liu, Shisen; Gu, Jing; Lin, Songshan; Zhao, Lisheng

    2016-03-25

    Periodontitis is a common chronic inflammatory disease. Recent studies have shown that chronic stress (CS) might modulate periodontal disease, but there are few models of CS-induced periodontitis, and the underlying mechanisms are unclear. The present study established a rat model of periodontitis associated with CS induced by nylon thread ligatures. The severity of periodontitis was evaluated in this model by radiographic and pathological examination. The inflammatory reaction indicated by the elevated serum levels of interleukin (IL)-1β, IL-6 and IL-8 was assessed by enzyme-linked immunosorbent assay. Toll-like receptor-4 (TLR4) and glucocorticoid receptor-α (GR-α) expressions were detected by reverse transcriptase-PCR and western blotting. Open-field tests and serum corticosterone were used to evaluate CS. The results showed that CS induced behavioral changes and increased corticosterone levels of the animals with periodontitis. CS stimulation markedly increased alveolar bone loss, periodontal pocket depth and the number of plaques. It also enhanced the inflammatory reaction. These results suggest that CS accelerated the ligature-induced pathological changes associated with periodontitis. Further analysis of the mechanisms involved showed that GR-α expression was significantly downregulated in periodontal tissues of the animals undergoing CS. Blocking GR-α signaling in lipopolysaccharide and corticosteroid-treated human periodontal ligament fibroblast cells in vitro significantly upregulated the expression of p-Akt (protein kinase B) and TLR4, promoted nuclear factor-κB activity and increased levels of IL-1β, IL-6 and IL-8. This research suggests that CS might accelerate the pathological progression of periodontitis by a GR-α signaling-mediated inflammatory response and that this may be a potential therapeutic target for the treatment of periodontal disease, particularly in patients with CS.

  16. Tyrosine kinase inhibition: A therapeutic target for the management of chronic-phase chronic myeloid leukemia

    Science.gov (United States)

    Jabbour, Elias J; Cortes, Jorge E; Kantarjian, Hagop M

    2014-01-01

    Chronic myeloid leukemia (CML) is a hematologic neoplasm with a progressive, ultimately terminal, disease course. In most cases, CML arises owing to the aberrant formation of a chimeric gene for a constitutively active tyrosine kinase. Inhibition of the signaling activity of this kinase has proved to be a highly successful treatment target transforming the prognosis of patients with CML. New tyrosine kinase inhibitors (TKIs) continue to improve the management of CML, offering alternative options for those resistant to or intolerant of standard TKIs. Here we review the pathobiology of CML and explore emerging strategies to optimize the management of chronic-phase CML, particularly first-line treatment. PMID:24236822

  17. Treatment-free remission following frontline nilotinib in patients with chronic myeloid leukemia in chronic phase: results from the ENESTfreedom study.

    Science.gov (United States)

    Hochhaus, A; Masszi, T; Giles, F J; Radich, J P; Ross, D M; Gómez Casares, M T; Hellmann, A; Stentoft, J; Conneally, E; García-Gutiérrez, V; Gattermann, N; Wiktor-Jedrzejczak, W; le Coutre, P D; Martino, B; Saussele, S; Menssen, H D; Deng, W; Krunic, N; Bedoucha, V; Saglio, G

    2017-07-01

    The single-arm, phase 2 ENESTfreedom trial assessed the potential for treatment-free remission (TFR; i.e., the ability to maintain a molecular response after stopping therapy) following frontline nilotinib treatment. Patients with Philadelphia chromosome-positive chronic myeloid leukemia in chronic phase with MR 4.5 (BCR-ABL1⩽0.0032% on the International Scale (BCR-ABL1 IS )) and ⩾2 years of frontline nilotinib therapy were enrolled. Patients with sustained deep molecular response during the 1-year nilotinib consolidation phase were eligible to stop treatment and enter the TFR phase. Patients with loss of major molecular response (MMR; BCR-ABL1 IS ⩽0.1%) during the TFR phase reinitiated nilotinib. In total, 215 patients entered the consolidation phase, of whom 190 entered the TFR phase. The median duration of nilotinib before stopping treatment was 43.5 months. At 48 weeks after stopping nilotinib, 98 patients (51.6%; 95% confidence interval, 44.2-58.9%) remained in MMR or better (primary end point). Of the 86 patients who restarted nilotinib in the treatment reinitiation phase after loss of MMR, 98.8% and 88.4%, respectively, regained MMR and MR 4.5 by the data cutoff date. Consistent with prior reports of imatinib-treated patients, musculoskeletal pain-related events were reported in 24.7% of patients in the TFR phase (consolidation phase, 16.3%).

  18. Two cases of chronic myelogenous leukemia (CML) treated with Iminitab (Glivec) in different phases

    International Nuclear Information System (INIS)

    Davoli, R.; Ciarlo, S.; Acosta, I.; Perez, S.; Lagorio, S.; Pratti, A.A.

    2003-01-01

    Full text: IMINITAB, inhibitor of cytoplasmic transduction signs, and hindering neoplastic cells growth, is a new therapeutic agent for chronic myelogenous leukemia (CML). It is a tyrosine kinase bcrabl inhibitor, inhibiting also the c-kit receptor protein in gastrointestinal neoplasia and small cells lung cancer. The aim of the present work was to evaluate the effect of this agent in CML patients in two different time-periods, namely the chronic phase and the acute one. We hereby present two patients: 1) a 48 years old patient with radioactive contamination history, and 2) a 19 years old patient. In both cases diagnosis was confirmed by BM and BM biopsy, neutrophile alkaline phosphatase, and Ph chromosome t(9;22) (q34;q11). There were non-compatible BM donors available. Both patients were treated with hydroxyurea, hydroxyurea plus interferon, and one of them adding ARAC. Since there was no favorable response an Iminitab course was started. Patient (2) with blastic crisis remitted for 12 month until subsequent relapse and death. Patient (1) treated during chronic phase is still in remission. Neither of them attained negative Ph chromosome. Up to now, current reports show a high percentage of relapse in patients treated during the acute phase, while the chronic ones present a smaller number of relapses. It is to be noted the importance of the follow up during the chronic phase, due to the short time drug utilization in our country (May 2001). Good tolerance and sustained remission in CML patients allows being optimistic regarding this therapeutic agent. (author)

  19. Laser-wakefield accelerators for medical phase contrast imaging: Monte Carlo simulations and experimental studies

    Science.gov (United States)

    Cipiccia, S.; Reboredo, D.; Vittoria, Fabio A.; Welsh, G. H.; Grant, P.; Grant, D. W.; Brunetti, E.; Wiggins, S. M.; Olivo, A.; Jaroszynski, D. A.

    2015-05-01

    X-ray phase contrast imaging (X-PCi) is a very promising method of dramatically enhancing the contrast of X-ray images of microscopic weakly absorbing objects and soft tissue, which may lead to significant advancement in medical imaging with high-resolution and low-dose. The interest in X-PCi is giving rise to a demand for effective simulation methods. Monte Carlo codes have been proved a valuable tool for studying X-PCi including coherent effects. The laser-plasma wakefield accelerators (LWFA) is a very compact particle accelerator that uses plasma as an accelerating medium. Accelerating gradient in excess of 1 GV/cm can be obtained, which makes them over a thousand times more compact than conventional accelerators. LWFA are also sources of brilliant betatron radiation, which are promising for applications including medical imaging. We present a study that explores the potential of LWFA-based betatron sources for medical X-PCi and investigate its resolution limit using numerical simulations based on the FLUKA Monte Carlo code, and present preliminary experimental results.

  20. Pion-decay radiation and two-phase acceleration in the June 3, 1982 solar flare

    Science.gov (United States)

    Ramaty, R.; Dermer, C. D.; Murphy, R. J.

    1986-01-01

    The June 3, 1982 flare is unique in the wealth of observed neutron, gamma-ray and energetic-particle emission that it produced. Using calculations of high-energy emissions to fit the various time-dependent gamma-ray fluxes, a self-consistent interaction model for the June 3 flare is constructed in which the observed fluxes are produced by two distinct particle populations with different acceleration and interaction time histories as well as different but time-independent energy spectra. The two populations are associated with first- and second-phase particle acceleration, respectively.

  1. Epidemiologic study on survival of chronic myeloid leukemia and Ph(+) acute lymphoblastic leukemia patients with BCR-ABL T315I mutation

    DEFF Research Database (Denmark)

    Nicolini, Franck E; Mauro, Michael J; Martinelli, Giovanni

    2009-01-01

    The BCR-ABL T315I mutation represents a major mechanism of resistance to tyrosine kinase inhibitors (TKIs). The objectives of this retrospective observational study were to estimate overall and progression-free survival for chronic myeloid leukemia in chronic-phase (CP), accelerated-phase (AP......), or blastic-phase (BP) and Philadelphia chromosome-positive (Ph)(+) acute lymphoblastic leukemia (ALL) patients with T315I mutation. Medical records of 222 patients from 9 countries were reviewed; data were analyzed using log-rank tests and Cox proportional hazard models. Median age at T315I mutation...

  2. Chronic Hepatitis B Virus Infection: The Relation between Hepatitis B Antigen Expression, Telomere Length, Senescence, Inflammation and Fibrosis.

    Directory of Open Access Journals (Sweden)

    Phaedra M Tachtatzis

    Full Text Available Chronic Hepatitis B virus (HBV infection can lead to the development of chronic hepatitis, cirrhosis and hepatocellular carcinoma. We hypothesized that HBV might accelerate hepatocyte ageing and investigated the effect of HBV on hepatocyte cell cycle state and biological age. We also investigated the relation between inflammation, fibrosis and cell cycle phase.Liver samples from patients with chronic HBV (n = 91, normal liver (n = 55 and regenerating liver (n = 15 were studied. Immunohistochemistry for cell cycle phase markers and HBV antigens was used to determine host cell cycle phase. Hepatocyte-specific telomere length was evaluated by quantitative fluorescent in-situ hybridization (Q-FISH in conjunction with hepatocyte nuclear area and HBV antigen expression. The effects of induced cell cycle arrest and induced cellular senescence on HBV production were assessed in vitro.13.7% hepatocytes in chronic HBV had entered cell cycle, but expression of markers for S, G2 and M phase was low compared with regenerating liver. Hepatocyte p21 expression was increased (10.9% in chronic HBV and correlated with liver fibrosis. Mean telomere length was reduced in chronic HBV compared to normal. However, within HBV-affected livers, hepatocytes expressing HBV antigens had longer telomeres. Telomere length declined and hepatocyte nuclear size increased as HBV core antigen (HBcAg expression shifted from the nucleus to cytoplasm. Nuclear co-expression of HBcAg and p21 was not observed. Cell cycle arrest induced in vitro was associated with increased HBV production, in contrast to in vitro induction of cellular senescence, which had no effect.Chronic HBV infection was associated with hepatocyte G1 cell cycle arrest and accelerated hepatocyte ageing, implying that HBV induced cellular senescence. However, HBV replication was confined to biologically younger hepatocytes. Changes in the cellular location of HBcAg may be related to the onset of cellular senescence.

  3. Relationship between Lower Limb Angular Kinematic Variables and the Effectiveness of Sprinting during the Acceleration Phase

    Directory of Open Access Journals (Sweden)

    Artur Struzik

    2016-01-01

    Full Text Available The ability to reach a high running velocity over a short distance is essential to a high playing performance in team games. The aim of this study was to determine the relationship between running time over a 10-meter section of a 30-meter sprint along a straight line and changes in the angle and angular velocity that were observed in the ankle, knee, and hip joints. The possible presence may help to optimize motion efficiency during acceleration sprint phase. Eighteen girls involved in team sports were examined in the study. The Fusion Smart Speed System was employed for running time measurements. The kinematic data were recorded using the Noraxon MyoMotion system. Statistically significant relationships were found between running time over a 10-meter section and the kinematic variables of hip and ankle joints. An excessively large flexion in hip joints might have an unfavorable effect on running time during the acceleration phase. Furthermore, in order to minimize running time during the acceleration phase, stride should be maintained along a line (a straight line rather than from side to side. It is also necessary to ensure an adequate range of motion in the hip and ankle joints with respect to the sagittal axis.

  4. Relationship between Lower Limb Angular Kinematic Variables and the Effectiveness of Sprinting during the Acceleration Phase.

    Science.gov (United States)

    Struzik, Artur; Konieczny, Grzegorz; Stawarz, Mateusz; Grzesik, Kamila; Winiarski, Sławomir; Rokita, Andrzej

    2016-01-01

    The ability to reach a high running velocity over a short distance is essential to a high playing performance in team games. The aim of this study was to determine the relationship between running time over a 10-meter section of a 30-meter sprint along a straight line and changes in the angle and angular velocity that were observed in the ankle, knee, and hip joints. The possible presence may help to optimize motion efficiency during acceleration sprint phase. Eighteen girls involved in team sports were examined in the study. The Fusion Smart Speed System was employed for running time measurements. The kinematic data were recorded using the Noraxon MyoMotion system. Statistically significant relationships were found between running time over a 10-meter section and the kinematic variables of hip and ankle joints. An excessively large flexion in hip joints might have an unfavorable effect on running time during the acceleration phase. Furthermore, in order to minimize running time during the acceleration phase, stride should be maintained along a line (a straight line) rather than from side to side. It is also necessary to ensure an adequate range of motion in the hip and ankle joints with respect to the sagittal axis.

  5. Trajectories of electrons with large longitudinal momenta in the phase plane during surfatron acceleration by an electromagnetic wave

    Energy Technology Data Exchange (ETDEWEB)

    Mkrtichyan, G. S., E-mail: hay-13@mail.ru [Peoples’ Friendship University of Russia (Russian Federation)

    2015-07-15

    The trajectories of electrons with large longitudinal momenta in the phase plane in the course of their surfatron acceleration by an electromagnetic wave propagating in space plasma across the external magnetic field are analyzed. Electrons with large longitudinal momenta are trapped immediately if the initial wave phase Ψ(0) on the particle trajectory is positive. For negative values of Ψ(0), no electrons trapping by the wave is observed over the available computational times. According to numerical calculations, the trajectories of trapped particles in the phase plane have a singular point of the stable focus type and the behavior of the trajectory corresponds to the motion in a complex nonstationary effective potential well. For some initial phases, electrons are confined in the region of the accelerating electric field for relatively short time, the energy gain being about 50–130% and more.

  6. Conditional survival in patients with chronic myeloid leukemia in chronic phase in the era of tyrosine kinase inhibitors.

    Science.gov (United States)

    Sasaki, Koji; Kantarjian, Hagop M; Jain, Preetesh; Jabbour, Elias J; Ravandi, Farhad; Konopleva, Marina; Borthakur, Gautam; Takahashi, Koichi; Pemmaraju, Naveen; Daver, Naval; Pierce, Sherry A; O'Brien, Susan M; Cortes, Jorge E

    2016-01-15

    Tyrosine kinase inhibitors (TKIs) significantly improve survival in patients with chronic myeloid leukemia in chronic phase (CML-CP). Conditional probability provides survival information in patients who have already survived for a specific period of time after treatment. Cumulative response and survival data from 6 consecutive frontline TKI clinical trials were analyzed. Conditional probability was calculated for failure-free survival (FFS), transformation-free survival (TFS), event-free survival (EFS), and overall survival (OS) according to depth of response within 1 year of the initiation of TKIs, including complete cytogenetic response, major molecular response, and molecular response with a 4-log or 4.5-log reduction. A total of 483 patients with a median follow-up of 99.4 months from the initiation of treatment with TKIs were analyzed. Conditional probabilities of FFS, TFS, EFS, and OS for 1 additional year for patients alive after 12 months of therapy ranged from 92.0% to 99.1%, 98.5% to 100%, 96.2% to 99.6%, and 96.8% to 99.7%, respectively. Conditional FFS for 1 additional year did not improve with a deeper response each year. Conditional probabilities of TFS, EFS, and OS for 1 additional year were maintained at >95% during the period. In the era of TKIs, patients with chronic myeloid leukemia in chronic phase who survived for a certain number of years maintained excellent clinical outcomes in each age group. Cancer 2016;122:238-248. © 2015 American Cancer Society. © 2015 American Cancer Society.

  7. Long-term safety and efficacy of dasatinib in the treatment of chronic-phase chronic myeloid leukemia patients resistant or intolerant to imatinib

    Directory of Open Access Journals (Sweden)

    Shoumariyeh K

    2014-09-01

    Full Text Available Khalid Shoumariyeh, Nikolas von BubnoffDepartment of Hematology, Oncology and Stem Cell Transplantation, University Hospital Freiburg, Freiburg, Germany Abstract: Treatment of chronic myeloid leukemia (CML has undergone dramatic changes in the last decade. Dissecting the molecular pathways that lead to the development of this disease resulted in the development of targeted therapy against the molecular driver of CML, namely the aberrantly activated tyrosine kinase BCR-ABL1. By introducing the tyrosine kinase inhibitor imatinib to the treatment repertoire, the natural course of the disease has been dramatically altered and overall survival of patients with CML prolonged substantially. Nevertheless, a significant number of patients are primarily resistant, acquire resistance during the course of their disease, or do not tolerate the intake of imatinib due to adverse effects. Second-generation tyrosine kinase inhibitors were developed in an attempt to overcome these problems. Dasatinib is a potent oral kinase inhibitor that was originally developed as an Src-kinase inhibitor but exhibited promising potency against BCR-ABL1 as well. Phase I and II trials demonstrated efficacy in patients failing imatinib, and thus dasatanib was approved in 2006 for the treatment of imatinib-resistant or -intolerant patients with chronic-phase CML harboring the BCR-ABL1 fusion protein. It has since shown promising efficacy and good overall tolerability in subsequent clinical trials, including the Phase III first-line DASISION trial that led to the extension of its approval for first-line treatment of chronic-phase CML. The following review summarizes the available data on the long-term efficacy and safety of dasatinib as a second-line therapy in chronic-phase CML. Keywords: BCR-ABL1, TKI, CML-CP, second-line treatment

  8. Major depressive disorder mediates accelerated aging in rats subjected to chronic mild stress.

    Science.gov (United States)

    Xie, Xiaoxian; Chen, Yangyang; Ma, Lingyan; Shen, Qichen; Huang, Liangfeng; Zhao, Binggong; Wu, Tao; Fu, Zhengwei

    2017-06-30

    Major depressive disorder (MDD) has a complex etiology and is characterized by a change in mood and psychophysiological state. MDD has been shown to mediate accelerated biological aging in patients, although the underlying mechanism is not well understood. In the present study, we used a chronic mild stress (CMS) paradigm to induce anhedonia, one of the main symptoms of MDD. CMS induced depression-like symptoms in rats, including reduced sucrose preference and increased immobility time in the forced swim test. Moreover, stressed rats travelled a shorter total distance, had fewer grid line crossings, and spent less time in the outer zone in the open field test than controls. CMS altered the levels of 5-hydroxytryptophan, dopamine, and corticosterone in the serum and hippocampus (P<0.05); these rats also exhibited impaired liver function, decreased telomerase activity, and telomere shortening, which was associated with increased oxidative damage along with decreased superoxide dismutase and glutathione reductase activities. Mitochondria in CMS-treated rats showed ultrastructural damage as well as reduced DNA content and integrity. These findings provide physiological and cellular evidence that the MDD can mediate accelerated aging in rats. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Test accelerator for linear collider

    International Nuclear Information System (INIS)

    Takeda, S.; Akai, K.; Akemoto, M.; Araki, S.; Hayano, H.; Hugo, T.; Ishihara, N.; Kawamoto, T.; Kimura, Y.; Kobayashi, H.; Kubo, T.; Kurokawa, S.; Matsumoto, H.; Mizuno, H.; Odagiri, J.; Otake, Y.; Sakai, H.; Shidara, T.; Shintake, T.; Suetake, M.; Takashima, T.; Takata, K.; Takeuchi, Y.; Urakawa, J.; Yamamoto, N.; Yokoya, K.; Yoshida, M.; Yoshioka, M.; Yamaoka, Y.

    1989-01-01

    KEK has proposed to build Test Accelerator Facility (TAF) capable of producing a 2.5 GeV electron beam for the purpose of stimulating R ampersand D for linear collider in TeV region. The TAF consists of a 1.5 GeV S-band linear accelerator, 1.5 GeV damping ring and 1.0 GeV X-band linear accelerator. The TAF project will be carried forward in three phases. Through Phase-I and Phase-II, the S-band and X-band linacs will be constructed, and in Phase-III, the damping ring will be completed. The construction of TAF Phase-I has started, and the 0.2 GeV S-band injector linac has been almost completed. The Phase-I linac is composed of a 240 keV electron gun, subharmonic bunchers, prebunchers and traveling buncher followed by high-gradient accelerating structures. The SLAC 5045 klystrons are driven at 450 kV in order to obtain the rf-power of 100 MW in a 1 μs pulse duration. The rf-power from a pair of klystrons are combined into an accelerating structure. The accelerating gradient up to 100 MeV/m will be obtained in a 0.6 m long structure. 5 refs., 3 figs., 2 tabs

  10. Chronic phase of Chagas disease: why should it be treated? A comprehensive review

    Directory of Open Access Journals (Sweden)

    José Rodrigues Coura

    2011-09-01

    Full Text Available The pathogenesis and evolutive pattern of Chagas disease suggests that the chronic phase should be more widely treated in order to (i eliminate Trypanosoma cruzi and prevent new inflammatory foci and the extension of tissue lesions, (ii promote tissue regeneration to prevent fibrosis, (iii reverse existing fibrosis, (iv prevent cardiomyopathy, megaoesophagus and megacolon and (v reduce or eliminate cardiac block and arrhythmia. All cases of the indeterminate chronic form of Chagas disease without contraindications due to other concomitant diseases or pregnancy should be treated and not only cases involving children or recently infected cases. Patients with chronic Chagas cardiomyopathy grade II of the New York Heart Association classification should be treated with specific chemotherapy and grade III can be treated according to medical-patient decisions. We are proposing the following new strategies for chemotherapeutic treatment of the chronic phase of Chagas disease: (i repeated short-term treatments for 30 consecutive days and interval of 30-60 days for six months to one year and (ii combinations of drugs with different mechanisms of action, such as benznidazole + nifurtimox, benznidazole or nifurtimox + allopurinol or triazole antifungal agents, inhibition of sterol synthesis.

  11. Results of the RAMI analyses performed for the IFMIF accelerator facility in the engineering design phase

    Energy Technology Data Exchange (ETDEWEB)

    Bargalló, Enric, E-mail: enric.bargallo@esss.se [Fusion Energy Engineering Laboratory (FEEL), Technical University of Catalonia (UPC) Barcelona-Tech, Barcelona (Spain); Arroyo, Jose Manuel [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, Madrid (Spain); Abal, Javier; Dies, Javier; De Blas, Alfredo; Tapia, Carlos [Fusion Energy Engineering Laboratory (FEEL), Technical University of Catalonia (UPC) Barcelona-Tech, Barcelona (Spain); Moya, Joaquin; Ibarra, Angel [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, Madrid (Spain)

    2015-10-15

    Highlights: • RAMI methodology used for IFMIF accelerator facility is presented. • Availability analyses and results are shown. • Main accelerator design changes are proposed. • Consequences and conclusions of the RAMI analyses are described. - Abstract: This paper presents a summary of the RAMI (Reliability Availability Maintainability Inspectability) analyses done for the IFMIF (International Fusion Materials Irradiation Facility) Accelerator facility in the Engineering Design Phase. The methodology followed, the analyses performed, the results obtained and the conclusions drawn are described. Moreover, the consequences of the incorporation of the RAMI studies in the IFMIF design are presented and the main outcomes of these analyses are shown.

  12. Results of the RAMI analyses performed for the IFMIF accelerator facility in the engineering design phase

    International Nuclear Information System (INIS)

    Bargalló, Enric; Arroyo, Jose Manuel; Abal, Javier; Dies, Javier; De Blas, Alfredo; Tapia, Carlos; Moya, Joaquin; Ibarra, Angel

    2015-01-01

    Highlights: • RAMI methodology used for IFMIF accelerator facility is presented. • Availability analyses and results are shown. • Main accelerator design changes are proposed. • Consequences and conclusions of the RAMI analyses are described. - Abstract: This paper presents a summary of the RAMI (Reliability Availability Maintainability Inspectability) analyses done for the IFMIF (International Fusion Materials Irradiation Facility) Accelerator facility in the Engineering Design Phase. The methodology followed, the analyses performed, the results obtained and the conclusions drawn are described. Moreover, the consequences of the incorporation of the RAMI studies in the IFMIF design are presented and the main outcomes of these analyses are shown.

  13. Induction accelerators for the phase rotator system

    International Nuclear Information System (INIS)

    Reginato, Lou; Yu, Simon; Vanecek, Dave

    2001-01-01

    The principle of magnetic induction has been applied to the acceleration of high current beams in betatrons and a variety of induction accelerators. The linear induction accelerator (LIA) consists of a simple nonresonant structure where the drive voltage is applied to an axially symmetric gap that encloses a toroidal ferromagnetic material. The change in flux in the magnetic core induces an axial electric field that provides particle acceleration. This simple nonresonant (low Q) structure acts as a single turn transformer that can accelerate from hundreds of amperes to tens of kiloamperes, basically only limited by the drive impedance. The LIA is typically a low gradient structure that can provide acceleration fields of varying shapes and time durations from tens of nanoseconds to several microseconds. The efficiency of the LIA depends on the beam current and can exceed 50% if the beam current exceeds the magnetization current required by the ferromagnetic material. The acceleration voltage available is simply given by the expression V=A dB/dt. Hence, for a given cross section of material, the beam pulse duration influences the energy gain. Furthermore, a premium is put on minimizing the diameter, which impacts the total weight or cost of the magnetic material. The diameter doubly impacts the cost of the LIA since the power (cost) to drive the cores is proportional to the volume as well. The waveform requirements during the beam pulse makes it necessary to make provisions in the pulsing system to maintain the desired dB/dt during the useful part of the acceleration cycle. This is typically done two ways, by using the final stage of the pulse forming network (PFN) and by the pulse compensation network usually in close proximity of the acceleration cell. The choice of magnetic materials will be made by testing various materials both ferromagnetic and ferrimagnetic. These materials will include the nickel-iron, silicon steel amorphous and various types of ferrites not

  14. Proposal for a study of laser acceleration of electrons using micrograting structures at ATF (Phase 1)

    International Nuclear Information System (INIS)

    Chen, W.; Claus, J.; Fernow, R.C.

    1989-01-01

    We propose to investigate new methods of particle acceleration using a short-pulse CO 2 laser as the power source and grating-like structures as accelerator ''cavities''. Phase I of this program is intended to demonstrate the principle of the method. We will focus the laser light to a 3 mm line on the surface of the microstructure. The structure is used to transform the electric field pattern of the incoming transversely polarized laser beam to a mode which has a component along the electron beam direction in the vicinity of the surface. With 6 mJ of laser energy and a 6 ps pulse length, the electric field in the spot will be around 1 GV/m. The electron beam from the Brookhaven Accelerator Test Facility (ATF) will be focused transversely within the few micron transverse dimension of the microstructure. The maximum expected acceleration for a 1 GV/m field and a 3 mm acceleration length is 3 MeV. 17 refs., 11 figs., 2 tabs

  15. Chronic escitalopram treatment attenuated the accelerated rapid eye movement sleep transitions after selective rapid eye movement sleep deprivation: a model-based analysis using Markov chains.

    Science.gov (United States)

    Kostyalik, Diána; Vas, Szilvia; Kátai, Zita; Kitka, Tamás; Gyertyán, István; Bagdy, Gyorgy; Tóthfalusi, László

    2014-11-19

    Shortened rapid eye movement (REM) sleep latency and increased REM sleep amount are presumed biological markers of depression. These sleep alterations are also observable in several animal models of depression as well as during the rebound sleep after selective REM sleep deprivation (RD). Furthermore, REM sleep fragmentation is typically associated with stress procedures and anxiety. The selective serotonin reuptake inhibitor (SSRI) antidepressants reduce REM sleep time and increase REM latency after acute dosing in normal condition and even during REM rebound following RD. However, their therapeutic outcome evolves only after weeks of treatment, and the effects of chronic treatment in REM-deprived animals have not been studied yet. Chronic escitalopram- (10 mg/kg/day, osmotic minipump for 24 days) or vehicle-treated rats were subjected to a 3-day-long RD on day 21 using the flower pot procedure or kept in home cage. On day 24, fronto-parietal electroencephalogram, electromyogram and motility were recorded in the first 2 h of the passive phase. The observed sleep patterns were characterized applying standard sleep metrics, by modelling the transitions between sleep phases using Markov chains and by spectral analysis. Based on Markov chain analysis, chronic escitalopram treatment attenuated the REM sleep fragmentation [accelerated transition rates between REM and non-REM (NREM) stages, decreased REM sleep residence time between two transitions] during the rebound sleep. Additionally, the antidepressant avoided the frequent awakenings during the first 30 min of recovery period. The spectral analysis showed that the SSRI prevented the RD-caused elevation in theta (5-9 Hz) power during slow-wave sleep. Conversely, based on the aggregate sleep metrics, escitalopram had only moderate effects and it did not significantly attenuate the REM rebound after RD. In conclusion, chronic SSRI treatment is capable of reducing several effects on sleep which might be the consequence

  16. Acute and "chronic" phase reaction-a mother of disease.

    Science.gov (United States)

    Bengmark, Stig

    2004-12-01

    The world is increasingly threatened by a global epidemic of chronic diseases. Almost half of the global morbidity and almost two thirds of global mortality is due to these diseases-approximately 35 million die each year from chronic diseases. And they continue to increase. Increasing evidence suggest that these diseases are associated with lifestyle, stress, lack of physical exercise, over-consumption of calorie-condensed foods rich in saturated fat, sugar and starch, but also under-consumption of antioxidant-rich fruits and vegetables. As a result the function of the innate immune system is severe impaired. This review discusses the changes induced in response to mental and physical stress and their association with the subsequent development of metabolic syndrome, and its association with various chronic diseases. The endothelial cells and their function appears to be of great importance, and the function of their cellular membranes of special importance to the function of the underlying cells; their ability to obtain nutrients and antioxidants and to eliminate waste products. The abdominal adipocytes seen to play a key role, as they have the ability to in stressful situations release much of proinflammatory cytokines, PAI-1 and free fatty acids compared to elsewhere in the body. The load on the liver of these various substances in often of greater magnitude than the liver can handle. Some of the most common chronic diseases and their potential association with acute and "chronic" phase response, and with metabolic syndrome are discussed separately. The need for studies with lifestyle modifications is especially emphasized.

  17. Exploration of phase stability in the surfatron accelerator

    International Nuclear Information System (INIS)

    Neuffer, D.V.

    1984-04-01

    Proton and electron motion in a laser beat-wave accelerator with a transverse magnetic field is explored. Parameters of stable acceleration are determined analytically and by simulation. The effects of synchrotron radiation on electron acceleration are also explored

  18. A study of phase control in the FEL [free electron laser] two-beam accelerator

    International Nuclear Information System (INIS)

    Sessler, A.M.; Whittum, D.H.; Wurtele, J.S.

    1989-08-01

    A formalism is developed for the analysis of a steady-state free electron laser (FEL) and is applied to the two-beam accelerator (TBA). Conditions are derived for the design of a FEL TBA with rf output power and phase insensitive to errors in both beam current and energy. An example is presented of a suitably phase insensitive TBA design with 100 reaccelerations employing untapered FEL sections and with low power rf input to each section. The theoretical analysis is confirmed by a single particle FEL simulations. 9 refs., 2 tabs

  19. The effects of anthropometry and leg muscle power on drive and transition phase of acceleration

    DEFF Research Database (Denmark)

    Nikolaidis, Pantelis T.; Ingebrigtsen, Jørgen; Jeffreys, Ian

    2016-01-01

    Background: The aim of this study was to examine the effect of anthropometry and leg muscle power on accelerative ability and its phases (drive and transition). METHODS: Thirty-six soccer players (age 12.4±1.2 years, body mass 49.9±8.9 kg and height 154.2±10.3 cm) were tested twice, in the beginn......Background: The aim of this study was to examine the effect of anthropometry and leg muscle power on accelerative ability and its phases (drive and transition). METHODS: Thirty-six soccer players (age 12.4±1.2 years, body mass 49.9±8.9 kg and height 154.2±10.3 cm) were tested twice......, in the beginning and in the end of competitive season, for anthropometric characteristics, countermovement jump and 20-meter acceleration (split 0-10 meters and 10-20 meters, indices of drive and transition, respectively). The soccer players were grouped according to seasonal changes in 20-meter acceleration (δacc...

  20. Chronic ethanol intake alters circadian phase shifting and free-running period in mice.

    Science.gov (United States)

    Seggio, Joseph A; Fixaris, Michael C; Reed, Jeffrey D; Logan, Ryan W; Rosenwasser, Alan M

    2009-08-01

    Chronic alcohol intake is associated with widespread disruptions in sleep and circadian rhythms in both human alcoholics and in experimental animals. Recent studies have demonstrated that chronic and acute ethanol treatments alter fundamental properties of the circadian pacemaker--including free-running period and responsiveness to photic and nonphotic phase-shifting stimuli--in rats and hamsters. In the present work, the authors extend these observations to the C57BL/6J mouse, an inbred strain characterized by very high levels of voluntary ethanol intake and by reliable and stable free-running circadian activity rhythms. Mice were housed individually in running-wheel cages under conditions of either voluntary or forced ethanol intake, whereas controls were maintained on plain water. Forced ethanol intake significantly attenuated photic phase delays (but not phase advances) and shortened free-running period in constant darkness, but voluntary ethanol intake failed to affect either of these parameters. Thus, high levels of chronic ethanol intake, beyond those normally achieved under voluntary drinking conditions, are required to alter fundamental circadian pacemaker properties in C57BL/6J mice. These observations may be related to the relative ethanol insensitivity displayed by this strain in several other phenotypic domains, including ethanol-induced sedation, ataxia, and withdrawal. Additional experiments will investigate chronobiological sensitivity to ethanol in a range of inbred strains showing diverse ethanol-related phenotypes.

  1. Ion acceleration in the plasma focus

    International Nuclear Information System (INIS)

    Deutsch, R.

    1982-09-01

    Experimental informations are used to estimate the time dependence of the current density in the plasma focus and the electromagnetic field is determined from the Maxwell equations. The acceleration of the ions in these fields is studied. A detailed analysis of the acceleration in the compression phase, in the expansion phase and during the evolution of the m=O instability is made. It is shown, that the appearance of fast selffocused quasineutral electron beams, as a result of the betatron acceleration, has a decisive importance in the ion acceleration during the m=O constriction. Models for electromagnetic ion acceleration are described for each phase. A concordance with many experimental results can be observed. (orig.)

  2. Quantum metrology of phase for accelerated two-level atom coupled with electromagnetic field with and without boundary

    Science.gov (United States)

    Yang, Ying; Liu, Xiaobao; Wang, Jieci; Jing, Jiliang

    2018-03-01

    We study how to improve the precision of the quantum estimation of phase for an uniformly accelerated atom in fluctuating electromagnetic field by reflecting boundaries. We find that the precision decreases with increases of the acceleration without the boundary. With the presence of a reflecting boundary, the precision depends on the atomic polarization, position and acceleration, which can be effectively enhanced compared to the case without boundary if we choose the appropriate conditions. In particular, with the presence of two parallel reflecting boundaries, we obtain the optimal precision for atomic parallel polarization and the special distance between two boundaries, as if the atom were shielded from the fluctuation.

  3. Imatinib mesylate is effective in children with chronic myelogenous leukemia in late chronic and advanced phase and in relapse after stem cell transplantation

    NARCIS (Netherlands)

    Millot, F; Guilhot, J; Nelken, B; Leblanc, T; De Bont, ES; Bekassy, AN; Gadner, H; Sufliarska, S; Stary, J; Gschaidmeier, H; Guilhot, F; Suttorp, M

    A multicentric phase 2 study was conducted to determine the efficiency and the tolerance of imatinib mesylate in children with chronic myelogenous leukemia (CML) in advanced phase of the disease, in relapse after stem cell transplantation, or in case of failure to an interferon a-based regimen. In

  4. Phase locked multiple rings in the radiation pressure ion acceleration process

    Science.gov (United States)

    Wan, Y.; Hua, J. F.; Pai, C.-H.; Li, F.; Wu, Y. P.; Lu, W.; Zhang, C. J.; Xu, X. L.; Joshi, C.; Mori, W. B.

    2018-04-01

    Laser contrast plays a crucial role for obtaining high quality ion beams in the radiation pressure ion acceleration (RPA) process. Through one- and two-dimensional particle-in-cell (PIC) simulations, we show that a plasma with a bi-peak density profile can be produced from a thin foil on the effects of a picosecond prepulse, and it can then lead to distinctive modulations in the ion phase space (phase locked double rings) when the main pulse interacts with the target. These fascinating ion dynamics are mainly due to the trapping effect from the ponderomotive potential well of a formed moving standing wave (i.e. the interference between the incoming pulse and the pulse reflected by a slowly moving surface) at nodes, quite different from the standard RPA process. A theoretical model is derived to explain the underlying mechanism, and good agreements have been achieved with PIC simulations.

  5. EEG patterns from acute to chronic stroke phases in focal cerebral ischemic rats: correlations with functional recovery.

    Science.gov (United States)

    Zhang, Shao-jie; Ke, Zheng; Li, Le; Yip, Shea-ping; Tong, Kai-yu

    2013-04-01

    Monitoring the neural activities from the ischemic penumbra provides critical information on neurological recovery after stroke. The purpose of this study is to evaluate the temporal alterations of neural activities using electroencephalography (EEG) from the acute phase to the chronic phase, and to compare EEG with the degree of post-stroke motor function recovery in a rat model of focal ischemic stroke. Male Sprague-Dawley rats were subjected to 90 min transient middle cerebral artery occlusion surgery followed by reperfusion for seven days (n = 58). The EEG signals were recorded at the pre-stroke phase (0 h), acute phase (3, 6 h), subacute phase (12, 24, 48, 72 h) and chronic phase (96, 120, 144, 168 h) (n = 8). This study analyzed post-stroke seizures and polymorphic delta activities (PDAs) and calculated quantitative EEG parameters such as the alpha-to-delta ratio (ADR). The ADR represented the ratio between alpha power and delta power, which indicated how fast the EEG activities were. Forelimb and hindlimb motor functions were measured by De Ryck's test and the beam walking test, respectively. In the acute phase, delta power increased fourfold with the occurrence of PDAs, and the histological staining showed that the infarct was limited to the striatum and secondary sensory cortex. In the subacute phase, the alpha power reduced to 50% of the baseline, and the infarct progressed to the forelimb cortical region. ADRs reduced from 0.23 ± 0.09 to 0.04 ± 0.01 at 3 h in the acute phase and gradually recovered to 0.22 ± 0.08 at 168 h in the chronic phase. In the comparison of correlations between the EEG parameters and the limb motor function from the acute phase to the chronic phase, ADRs were found to have the highest correlation coefficients with the beam walking test (r = 0.9524, p test (r = 0.8077, p < 0.05). This study measured EEG activities after focal cerebral ischemia and showed that functional recovery was closely correlated with the neural

  6. EEG patterns from acute to chronic stroke phases in focal cerebral ischemic rats: correlations with functional recovery

    International Nuclear Information System (INIS)

    Zhang, Shao-jie; Ke, Zheng; Tong, Kai-yu; Li, Le; Yip, Shea-ping

    2013-01-01

    Monitoring the neural activities from the ischemic penumbra provides critical information on neurological recovery after stroke. The purpose of this study is to evaluate the temporal alterations of neural activities using electroencephalography (EEG) from the acute phase to the chronic phase, and to compare EEG with the degree of post-stroke motor function recovery in a rat model of focal ischemic stroke. Male Sprague–Dawley rats were subjected to 90 min transient middle cerebral artery occlusion surgery followed by reperfusion for seven days (n = 58). The EEG signals were recorded at the pre-stroke phase (0 h), acute phase (3, 6 h), subacute phase (12, 24, 48, 72 h) and chronic phase (96, 120, 144, 168 h) (n = 8). This study analyzed post-stroke seizures and polymorphic delta activities (PDAs) and calculated quantitative EEG parameters such as the alpha-to-delta ratio (ADR). The ADR represented the ratio between alpha power and delta power, which indicated how fast the EEG activities were. Forelimb and hindlimb motor functions were measured by De Ryck's test and the beam walking test, respectively. In the acute phase, delta power increased fourfold with the occurrence of PDAs, and the histological staining showed that the infarct was limited to the striatum and secondary sensory cortex. In the subacute phase, the alpha power reduced to 50% of the baseline, and the infarct progressed to the forelimb cortical region. ADRs reduced from 0.23 ± 0.09 to 0.04 ± 0.01 at 3 h in the acute phase and gradually recovered to 0.22 ± 0.08 at 168 h in the chronic phase. In the comparison of correlations between the EEG parameters and the limb motor function from the acute phase to the chronic phase, ADRs were found to have the highest correlation coefficients with the beam walking test (r = 0.9524, p < 0.05) and De Ryck's test (r = 0.8077, p < 0.05). This study measured EEG activities after focal cerebral ischemia and showed that functional recovery was closely

  7. Transverse phase space diagnostics for ionization injection in laser plasma acceleration using permanent magnetic quadrupoles

    Science.gov (United States)

    Li, F.; Nie, Z.; Wu, Y. P.; Guo, B.; Zhang, X. H.; Huang, S.; Zhang, J.; Cheng, Z.; Ma, Y.; Fang, Y.; Zhang, C. J.; Wan, Y.; Xu, X. L.; Hua, J. F.; Pai, C. H.; Lu, W.; Mori, W. B.

    2018-04-01

    We report the transverse phase space diagnostics for electron beams generated through ionization injection in a laser-plasma accelerator. Single-shot measurements of both ultimate emittance and Twiss parameters are achieved by means of permanent magnetic quadrupole. Beams with emittance of μm rad level are obtained in a typical ionization injection scheme, and the dependence on nitrogen concentration and charge density is studied experimentally and confirmed by simulations. A key feature of the transverse phase space, matched beams with Twiss parameter α T ≃ 0, is identified according to the measurement. Numerical simulations that are in qualitative agreement with the experimental results reveal that a sufficient phase mixing induced by an overlong injection length leads to the matched phase space distribution.

  8. Collective ion acceleration

    International Nuclear Information System (INIS)

    Godfrey, B.B.; Faehl, R.J.; Newberger, B.S.; Shanahan, W.R.; Thode, L.E.

    1977-01-01

    Progress achieved in the understanding and development of collective ion acceleration is presented. Extensive analytic and computational studies of slow cyclotron wave growth on an electron beam in a helix amplifier were performed. Research included precise determination of linear coupling between beam and helix, suppression of undesired transients and end effects, and two-dimensional simulations of wave growth in physically realizable systems. Electrostatic well depths produced exceed requirements for the Autoresonant Ion Acceleration feasibility experiment. Acceleration of test ions to modest energies in the troughs of such waves was also demonstrated. Smaller efforts were devoted to alternative acceleration mechanisms. Langmuir wave phase velocity in Converging Guide Acceleration was calculated as a function of the ratio of electron beam current to space-charge limiting current. A new collective acceleration approach, in which cyclotron wave phase velocity is varied by modulation of electron beam voltage, is proposed. Acceleration by traveling Virtual Cathode or Localized Pinch was considered, but appears less promising. In support of this research, fundamental investigations of beam propagation in evacuated waveguides, of nonneutral beam linear eigenmodes, and of beam stability were carried out. Several computer programs were developed or enhanced. Plans for future work are discussed

  9. TIARA electrostatic accelerator facility

    International Nuclear Information System (INIS)

    Tajima, Satoshi; Takada, Isao; Mizuhashi, Kiyoshi; Uno, Sadanori; Ohkoshi, Kiyonori; Nakajima, Yoshinori; Saitoh, Yuichi; Ishii, Yasuyuki; Kamiya, Tomihiro

    1996-07-01

    In order to promote the Advanced Radiation Technology Project, Japan Atomic Energy Research Institute constructed TIARA facility composed of four ion accelerators at Takasaki Radiation Chemistry Research Establishment for the period from 1988 to 1993. A 3MV tandem accelerator and an AVF cycrotron were completed in 1991 as the first phase of the construction, and a 3MV single-ended accelerator and a 400kV ion implanter were completed in 1993 as the second phase. Three electrostatic accelerators, the tandem, the single-ended and the implanter, were installed in the Multiple-beam facility of TIARA and have been operated for various experiments with using single, dual and triple beams without any serious trouble. This report describes the constructive works, machine performances, control systems, safety systems and accessory equipments of the electrostatic accelerators. (author)

  10. High-energy inverse free-electron laser accelerator

    International Nuclear Information System (INIS)

    Courant, E.D.; Pellegrini, C.; Zakowicz, W.

    1985-01-01

    We study the inverse free electron laser (IFEL) accelerator and show that it can accelerate electrons to the few hundred GeV region with average acceleration rates of the order of 200 meV/m. Several possible accelerating structures are analyzed, and the effect of synchrotron radiation losses is studied. The longitudinal phase stability of accelerated particles is also analyzed. A Hamiltonian description, which takes into account the dissipative features of the IFEL accelerator, is introduced to study perturbations from the resonant acceleration. Adiabatic invariants are obtained and used to estimate the change of the electron phase space density during the acceleration process

  11. Acute versus chronic phase mechanisms in a rat model of CRPS.

    Science.gov (United States)

    Wei, Tzuping; Guo, Tian-Zhi; Li, Wen-Wu; Kingery, Wade S; Clark, John David

    2016-01-19

    Tibia fracture followed by cast immobilization in rats evokes nociceptive, vascular, epidermal, and bone changes resembling complex regional pain syndrome (CRPS). In most cases, CRPS has three stages. Over time, this acute picture, allodynia, warmth, and edema observed at 4 weeks, gives way to a cold, dystrophic but still painful limb. In the acute phase (at 4 weeks post fracture), cutaneous immunological and NK1-receptor signaling mechanisms underlying CRPS have been discovered; however, the mechanisms responsible for the chronic phase are still unknown. The purpose of this study is to understand the mechanisms responsible for the chronic phases of CRPS (at 16 weeks post fracture) at both the peripheral and central levels. We used rat tibial fracture/cast immobilization model of CRPS to study molecular, vascular, and nociceptive changes at 4 and 16 weeks post fracture. Immunoassays and Western blotting were carried out to monitor changes in inflammatory response and NK1-receptor signaling in the skin and spinal cord. Skin temperature and thickness were measured to elucidate vascular changes, whereas von Frey testing and unweighting were carried out to study nociceptive changes. All data were analyzed by one-way analysis of variance (ANOVA) followed by Neuman-Keuls multiple comparison test to compare among all cohorts. In the acute phase (at 4 weeks post fracture), hindpaw allodynia, unweighting, warmth, edema, and/or epidermal thickening were observed among 90 % fracture rats, though by 16 weeks (chronic phase), only the nociceptive changes persisted. The expression of the neuropeptide signaling molecule substance P (SP), NK1 receptor, inflammatory mediators TNFα, IL-1β, and IL-6 and nerve growth factor (NGF) were elevated at 4 weeks in sciatic nerve and/or skin, returning to normal levels by 16 weeks post fracture. The systemic administration of a peripherally restricted IL-1 receptor antagonist (anakinra) or of anti-NGF inhibited nociceptive behaviors at 4

  12. Relationship between myocardial flow reserve by oxygen-15 water positron emission tomography in the subacute phase of myocardial infarction and left ventricular remodeling in the chronic phase

    International Nuclear Information System (INIS)

    Ohara, Minako; Yukiiri, Kazushi; Masugata, Hisashi

    2008-01-01

    The purposes of this study were to examine the effects of angiotensin-converting enzyme inhibitors (ACEI) or angiotensin receptor blockers (ARB) on myocardial flow reserve in patients with acute myocardial infarction (AMI) in the subacute phase using oxygen-15 positron emission tomography (PET) and to elucidate the relationship between the myocardial flow reserve and remodeling in the chronic phase. Sixty patients who had been treated with coronary angioplasty within 12 h after the onset of AMI were enrolled. Patients were divided into an enalapril (ACEI) group and a candesartan (ARB) group. The myocardial flow reserve was measured by oxygen-15 water PET in the subacute phase from the 20th to the 30th day after the onset of AMI. Left ventriculography was performed to measure the left ventricular ejection fraction in the chronic phase about 6 months after the onset. Ten patients (33%) in the enalapril group and 4 patients (13%) in the candesartan group stopped taking their respective medications within a few days of starting, because of side effects such as cough or hypotension. Thus, the prevalence of medication intolerance was higher in the enalapril group. The myocardial flow reserve in the subacute phase and the left ventricular ejection fraction in the chronic phase were lower in the enalapril group (2.08±0.30 and 42±6%) than in the candesartan group (2.25±0.20 and 49±5%) (p<0.05). The myocardial flow reserve significantly correlated with the left ventricular ejection fraction in all patients (r=0.45, p<0.01). The myocardial flow reserve assessed by PET in the subacute phase after AMI was found to be related to left ventricular remodeling in the chronic phase. (author)

  13. Bosutinib in the management of chronic myelogenous leukemia

    Directory of Open Access Journals (Sweden)

    Keller-von Amsberg G

    2013-05-01

    Full Text Available Gunhild Keller-von Amsberg, Philippe SchafhausenDepartment of Hematology and Oncology and, Stem Cell Transplantation and Pulmonology Division, Oncological Center, University Hospital Hamburg-Eppendorf, Hamburg, GermanyAbstract: Bosutinib (SKI-606 is an orally available, once-daily dual Src and Abl kinase inhibitor, approved by the US Food and Drug Administration for the treatment of adults with chronic, accelerated, or blast-phase Philadelphia chromosome-positive chronic myelogenous leukemia who are intolerant of or resistant to first- or second-generation tyrosine kinase inhibitors. Bosutinib effectively overcomes the majority of imatinib-resistance-conferring BCR-ABL mutations except V299L and T315I. In the Bosutinib Efficacy and Safety in chronic myeloid LeukemiA (BELA trial, bosutinib attained a faster and deeper molecular response than imatinib in newly diagnosed chronic-phase chronic myelogenous leukemia patients. Treatment-emergent adverse events are usually very manageable. Low grade, mostly self-limiting diarrhea represents the most frequently observed toxicity of bosutinib. Anti-diarrheal drugs, antiemetic agents, and/or fluid replacement should be used to treat these patients. The improved hematological toxicity of bosutinib compared with other tyrosine kinase inhibitors has been ascribed to its minimal activity against platelet-derived growth factor receptor and KIT. In this review, we give an overview on the profile of bosutinib, the clinical potential and treatment-emergent adverse events.Keywords: CML, BCR-ABL, SRC/ABL kinase inhibitor, resistance-conferring mutation

  14. Granulocytic sarcoma in a patient with chronic myeloid leukaemia in complete haematological, cytogenetic and molecular remission.

    Science.gov (United States)

    Kittai, Adam; Yu, Eun-Mi; Tabbara, Imad

    2014-12-23

    Granulocytic sarcoma, also known as myeloid sarcoma, is an extramedullary tumour composed of immature myeloid cells. Granulocytic sarcoma is typically found in patients with acute myeloid leukaemia, accelerated phase or blast crisis of chronic myeloid leukaemia, myelodysplastic syndrome, or as an isolated event without bone marrow involvement. We present a case of granulocytic sarcoma in a patient with chronic myeloid leukaemia in the setting of complete haematological, molecular and cytogenetic remission. Our patient was first treated with imatinib for chronic-phase chronic myeloid leukaemia. After maintaining remission for 42 months, he developed a granulocytic sarcoma in his spine. In this case report, we describe our case, along with the three other cases reported in the literature. In addition to being a rare diagnosis, this case demonstrates the importance of being vigilant in diagnosing the cause of back pain and atypical symptoms in patients with a history of leukaemia. 2014 BMJ Publishing Group Ltd.

  15. Linear resonance acceleration of pellets

    International Nuclear Information System (INIS)

    Mills, R.G.

    1978-01-01

    A possible requirement for the acceleration of macroscopic pellets to velocities exceeding 10 4 meters per second implies the development of new apparatus. A satisfactory approach might be the linear resonance accelerator. Such apparatus would require the charging of pellets to very high values not yet demonstrated. The incompatibility of phase stability with radial stability in these machines may require abandoning phase stability and adopting feedback control of the accelerating voltage to accommodate statistical fluctuations in the charge to mass ratio of successive pellets

  16. Bosutinib efficacy and safety in chronic phase chronic myeloid leukemia after imatinib resistance or intolerance : Minimum 24-month follow-up

    NARCIS (Netherlands)

    Gambacorti-Passerini, Carlo; Brümmendorf, Tim H; Kim, Dong-Wook; Turkina, Anna G; Masszi, Tamas; Assouline, Sarit; Durrant, Simon; Kantarjian, Hagop M; Khoury, H Jean; Zaritskey, Andrey; Shen, Zhi-Xiang; Jin, Jie; Vellenga, Edo; Pasquini, Ricardo; Mathews, Vikram; Cervantes, Francisco; Besson, Nadine; Turnbull, Kathleen; Leip, Eric; Kelly, Virginia; Cortes, Jorge E

    Bosutinib is an orally active, dual Src/Abl tyrosine kinase inhibitor for treatment of chronic myeloid leukemia (CML) following resistance/intolerance to prior therapy. Here, we report the data from the 2-year follow-up of a phase 1/2 open-label study evaluating the efficacy and safety of bosutinib

  17. Accelerator reliability workshop

    International Nuclear Information System (INIS)

    Hardy, L.; Duru, Ph.; Koch, J.M.; Revol, J.L.; Van Vaerenbergh, P.; Volpe, A.M.; Clugnet, K.; Dely, A.; Goodhew, D.

    2002-01-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop

  18. Accelerator reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, L; Duru, Ph; Koch, J M; Revol, J L; Van Vaerenbergh, P; Volpe, A M; Clugnet, K; Dely, A; Goodhew, D

    2002-07-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop.

  19. Magnetic resonance tissue phase mapping demonstrates altered left ventricular diastolic function in children with chronic kidney disease

    International Nuclear Information System (INIS)

    Gimpel, Charlotte; Pohl, Martin; Jung, Bernd A.; Jung, Sabine; Brado, Johannes; Odening, Katja E.; Schwendinger, Daniel; Burkhardt, Barbara; Geiger, Julia; Arnold, Raoul

    2017-01-01

    Echocardiographic examinations have revealed functional cardiac abnormalities in children with chronic kidney disease. To assess the feasibility of MRI tissue phase mapping in children and to assess regional left ventricular wall movements in children with chronic kidney disease. Twenty pediatric patients with chronic kidney disease (before or after renal transplantation) and 12 healthy controls underwent tissue phase mapping (TPM) to quantify regional left ventricular function through myocardial long (Vz) and short-axis (Vr) velocities at all 3 levels of the left ventricle. Patients and controls (age: 8 years - 20 years) were matched for age, height, weight, gender and heart rate. Patients had higher systolic blood pressure. No patient had left ventricular hypertrophy on MRI or diastolic dysfunction on echocardiography. Fifteen patients underwent tissue Doppler echocardiography, with normal z-scores for mitral early diastolic (V E ), late diastolic (V A ) and peak systolic (V S ) velocities. Throughout all left ventricular levels, peak diastolic Vz and Vr (cm/s) were reduced in patients: Vz base -10.6 ± 1.9 vs. -13.4 ± 2.0 (P < 0.0003), Vz mid -7.8 ± 1.6 vs. -11 ± 1.5 (P < 0.0001), Vz apex -3.8 ± 1.6 vs. -5.3 ± 1.6 (P = 0.01), Vr base -4.2 ± 0.8 vs. -4.9 ± 0.7 (P = 0.01), Vr mid -4.7 ± 0.7 vs. -5.4 ± 0.7 (P = 0.01), Vr apex -4.7 ± 1.4 vs. -5.6 ± 1.1 (P = 0.05). Tissue phase mapping is feasible in children and adolescents. Children with chronic kidney disease show significantly reduced peak diastolic long- and short-axis left ventricular wall velocities, reflecting impaired early diastolic filling. Thus, tissue phase mapping detects chronic kidney disease-related functional myocardial changes before overt left ventricular hypertrophy or echocardiographic diastolic dysfunction occurs. (orig.)

  20. Interacting with accelerators

    International Nuclear Information System (INIS)

    Dasgupta, S.

    1994-01-01

    Accelerators are research machines which produce energetic particle beam for use as projectiles to effect nuclear reactions. These machines along with their services and facilities may occupy very large areas. The man-machine interface of accelerators has evolved with technological changes in the computer industry and may be partitioned into three phases. The present paper traces the evolution of man-machine interface from the earliest accelerators to the present computerized systems incorporated in modern accelerators. It also discusses the advantages of incorporating expert system technology for assisting operators. (author). 8 ref

  1. Laser wakefield acceleration

    International Nuclear Information System (INIS)

    Esarey, E.; Ting, A.; Sprangle, P.

    1989-01-01

    The laser wakefield accelerator (LWFA) is a novel plasma based electron acceleration scheme which utilizes a relativistic optical guiding mechanism for laser pulse propagation. In the LWFA, a short, high power, single frequency laser pulse is propagated through a plasma. As the laser pulse propagates, its radial and axial ponderomotive forces nonresonantly generate large amplitude plasma waves (wakefields) with a phase velocity equal to the group velocity of the pulse. A properly phased electron bunch may then be accelerated by the axial wakefield and focused by the transverse wakefield. Optical guiding of the laser pulse in the plasma is necessary in order to achieve high energies in a single stage of acceleration. At sufficiently high laser powers, optical guiding may be achieved through relativistic effects associated with the plasma electrons. Preliminary analysis indicates that this scheme may overcome some of the difficulties present in the plasma beat wave accelerator and in the plasma wakefield accelerator. Analytical and numerical calculations are presented which study both laser pulse propagation within a plasma as well as the subsequent generation of large amplitude plasma waves. In addition, the generation of large amplitude plasma waves in regimes where the plasma waves become highly nonlinear is examined

  2. Laser-driven acceleration with Bessel beam

    International Nuclear Information System (INIS)

    Imasaki, Kazuo; Li, Dazhi

    2005-01-01

    A new approach of laser-driven acceleration with Bessel beam is described. Bessel beam, in contrast to the Gaussian beam, shows diffraction-free'' characteristics in its propagation, which implies potential in laser-driven acceleration. But a normal laser, even if the Bessel beam, laser can not accelerate charged particle efficiently because the difference of velocity between the particle and photon makes cyclic acceleration and deceleration phase. We proposed a Bessel beam truncated by a set of annular slits those makes several special regions in its travelling path, where the laser field becomes very weak and the accelerated particles are possible to receive no deceleration as they undergo decelerating phase. Thus, multistage acceleration is realizable with high gradient. In a numerical computation, we have shown the potential of multistage acceleration based on a three-stage model. (author)

  3. General accelerator physics. Proceedings. Vol. 2

    International Nuclear Information System (INIS)

    Bryant, P.; Turner, S.

    1985-01-01

    This course on accelerator physics is the first in a series of two, which is planned by the CERN Accelerator School. Starting at the level of a science graduate, this course covers mainly linear theory. The topics include: transverse and longitudinal beam dynamics, insertions, coupling, transition, dynamics of radiating particles, space-charge forces, neutralization, beam profiles, luminosity calculations in colliders, longitudinal phase-space stacking, phase-displacement acceleration, transfer lines, injection and extraction. Some more advanced topics are also introduced: coherent instabilities in coasting beams, general collective phenomena, quantum lifetime, and intra-beam scattering. The seminar programme is based on two themes: firstly, the sub-systems of an accelerator and, secondly, the uses to which accelerators are put. (orig.)

  4. Open Label, Phase II Study to Evaluate Efficacy and Safety of Oral Nilotinib in Philadelphia Positive (Ph+) Chronic Myelogenous Leukemia (CML) Pediatric Patients.

    Science.gov (United States)

    2018-04-20

    Leukemia; Leukemia,Pediatric; Leukemia, Myleiod; Leukemia, Mylegenous, Chronic; Leukemia, Mylegenous, Accelerated; BCR-ABL Positive; Myeloproliferative Disorder; Bone Marrow Disease; Hematologic Diseases; Neoplastic Processes; Imatinib; Dasatinib; Enzyme Inhibitor; Protein Kinase Inhibitor

  5. ``Trickle Meter Gravimetry'': Precision Interferometry from Residual Berry Phase Edge Effects Involving Atoms Exiting an Accelerating Optical Lattice

    Science.gov (United States)

    Chubb, Scott

    2007-03-01

    From a generalization of conventional band theory, derived from a many-body form of multiple scattering theory, I rigorously showed that the semi-classical theory of cold atom transport in optical lattices could be related to changes in the zero of momentum of the ground state. The new formulation includes finite size effects. When the effects of excitation, associated with the loss of atoms at the boundaries of the lattice are included, in the adiabatic limit, in which the perturbing potential acts sufficiently slowly and weakly, topological changes in phase (which are equivalent to Berry phase effects in the conventional semi-classical theory) take place that introduce discontinuous changes in wave function phase (and flux). In a situation involving an accelerating optical lattice, containing ultra cold atoms in a Bose Einstein Condensate, these changes in wave function phase can be monitored and used to systematically alter the acceleration of the lattice (by altering the chirp frequency of one of one of the counter-propogating lasers), in such a way that a form of edge-effect interferometry can be performed, which, in principle, can be used to make precision measurements of gravity, with unprecedented accuracy. S.R.Chubb, Proc Roy Soc A, submitted (2006).

  6. The surface quasiliquid melt acceleration and the role of thermodynamic phase in the thermal decomposition of crystalline organic explosives

    Energy Technology Data Exchange (ETDEWEB)

    Henson, Bryan F [Los Alamos National Laboratory

    2010-01-01

    We show that melt acceleration in the thermal decomposition of crystalline organic solids is a manifestation of the surface quasiliquid phase. We derive a single universal rate law for melt acceleration that is a simple function of the metastable liquid activity below the melting point, and has a zero order term proportional to the quasiliquid thickness. We argue that the underlying mechanisms of this model will provide a molecular definition for the stability of the class of secondary explosives.

  7. Decay-accelerating factor 1 deficiency exacerbates Trypanosoma cruzi-induced murine chronic myositis.

    Science.gov (United States)

    Solana, María E; Ferrer, María F; Novoa, María Mercedes; Song, Wen-Chao; Gómez, Ricardo M

    2012-10-01

    Murine infection with Trypanosoma cruzi (Tc) has been used to study the role of T-cells in the pathogenesis of human inflammatory idiopathic myositis. Absence of decay-accelerating factor 1 (Daf1) has been shown to enhance murine T-cell responses and autoimmunity. To determine whether Daf1 deficiency can exacerbate Tc-induced myositis, C57BL/6 DAF(+/+) and DAF(-/-) mice were inoculated with 5 × 10(4) trypomastigotes, and their morbidity, parasitemia, parasite burden, histopathology, and T-cell expansion were studied in the acute and chronic stages. DAF(-/-) mice had lower parasitemia and parasite burden but higher morbidity, muscle histopathology, and increased number of CD44(+) (activated/memory phenotype) splenic CD4(+) and CD8(+) T-cells. An enhanced CD8(+) T-cell immune-specific response may explain the lower parasitemia and parasite burden levels and the increase in histopathological lesions. We propose that Tc-inoculated DAF(-/-) mice are a useful model to study T-cell mediated immunity in skeletal muscle tissues. Copyright © 2012 Wiley Periodicals, Inc.

  8. Neutron induced activation in the EVEDA accelerator materials: Implications for the accelerator maintenance

    International Nuclear Information System (INIS)

    Sanz, J.; Garcia, M.; Sauvan, P.; Lopez, D.; Moreno, C.; Ibarra, A.; Sedano, L.

    2009-01-01

    The Engineering Validation and Engineering Design Activities (EVEDA) phase of the International Fusion Materials Irradiation Facility project should result in an accelerator prototype for which the analysis of the dose rates evolution during the beam-off phase is a necessary task for radioprotection and maintenance feasibility purposes. Important aspects of the computational methodology to address this problem are discussed, and dose rates for workers inside the accelerator vault are assessed and found to be not negligible.

  9. Neutron induced activation in the EVEDA accelerator materials: Implications for the accelerator maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, J. [Department of Power Engineering, Universidad Nacional de Educacion a Distancia (UNED), C/Juan del Rosal 12, 28040 Madrid (Spain); Institute of Nuclear Fusion, UPM, 28006 Madrid (Spain)], E-mail: jsanz@ind.uned.es; Garcia, M.; Sauvan, P.; Lopez, D. [Department of Power Engineering, Universidad Nacional de Educacion a Distancia (UNED), C/Juan del Rosal 12, 28040 Madrid (Spain); Institute of Nuclear Fusion, UPM, 28006 Madrid (Spain); Moreno, C.; Ibarra, A.; Sedano, L. [CIEMAT, 28040 Madrid (Spain)

    2009-04-30

    The Engineering Validation and Engineering Design Activities (EVEDA) phase of the International Fusion Materials Irradiation Facility project should result in an accelerator prototype for which the analysis of the dose rates evolution during the beam-off phase is a necessary task for radioprotection and maintenance feasibility purposes. Important aspects of the computational methodology to address this problem are discussed, and dose rates for workers inside the accelerator vault are assessed and found to be not negligible.

  10. CAS CERN Accelerator School: Advanced accelerator physics. Proceedings. Vol. 2

    International Nuclear Information System (INIS)

    Turner, S.

    1987-01-01

    This advanced course on general accelerator physics is the second of the biennial series given by the CERN Accelerator School and follows on from the first basic course given at Gif-sur-Yvette, Paris, in 1984. Stress is placed on the mathematical tools of Hamiltonian mechanics and the Vlasov and Fokker-Planck equations, which are widely used in accelerator theory. The main topics treated in this present work include: nonlinear resonances, chromaticity, motion in longitudinal phase space, growth and control of longitudinal and transverse beam emittance, space-charge effects and polarization. The seminar programme treats some specific accelerator techniques, devices, projects and future possibilities. (orig.)

  11. Towards stable acceleration in LINACS

    CERN Document Server

    Dubrovskiy, A D

    2014-01-01

    Ultra-stable and -reproducible high-energy particle beams with short bunches are needed in novel linear accelerators and, in particular, in the Compact Linear Collider CLIC. A passive beam phase stabilization system based on a bunch compression with a negative transfer matrix element R56 and acceleration at a positive off-crest phase is proposed. The motivation and expected advantages of the proposed scheme are outlined.

  12. Dysregulated physiological stress systems and accelerated cellular aging

    NARCIS (Netherlands)

    Révész, D.; Verhoeven, J.; Milaneschi, Y.; de Geus, E.J.C.; Wolkowitz, O.M.; Penninx, B.W.J.H.

    2014-01-01

    Exposure to chronic stressors is associated with accelerated biological aging as indicated by reduced leukocyte telomere length (LTL). This impact could be because of chronic overactivation of the body's physiological stress systems. This study examined the associations between LTL and the immune

  13. Single-particle dynamics - RF acceleration

    International Nuclear Information System (INIS)

    Montague, B.W.

    1977-01-01

    In this paper the rf acceleration of both synchronous and non-synchronous particles is discussed and a simple linearized equation of small amplitude synchrotron oscillations is derived. Phase stability, the hamiltonian for synchrotron oscillations, oscillation amplitudes and adiabatic damping are then briefly discussed. The final sections of the paper contain a description of the basic principles of rf beam stacking in the longitudinal phase space of intersecting Storage Rings and a description of phase displacement acceleration which inspite of certain disadvantages, remains an attractive technique for proton storage rings. (B.D.)

  14. A Phase I Trial of Epstein-Barr Virus Gp350 Vaccine for Children With Chronic Kidney Disease Awaiting Transplantation

    NARCIS (Netherlands)

    Rees, L.; Tizard, E.J.; Morgan, A.J.; Cubitt, W.D.; Finerty, S.; Oyewole-Eletu, T.A.; Owen, K.; Royed, C.; Stevens, S.J.C.; Shroff, R.C.; Tanday, M.K.; Wilson, A.; Middeldorp, J.M.; Amlot, P.L.; Steven, N.M.

    2009-01-01

    Background. Vaccination against Epstein-Barr virus (EBV), inducing an antibody response to the envelope glycoprotein gp350, might protect EBV-negative children with chronic kidney disease from lymphoproliferative disease after transplantation. Methods. A phase I trial recruited children with chronic

  15. Gymnastics in Phase Space

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alexander Wu; /SLAC

    2012-03-01

    As accelerator technology advances, the requirements on accelerator beam quality become increasingly demanding. Facing these new demands, the topic of phase space gymnastics is becoming a new focus of accelerator physics R&D. In a phase space gymnastics, the beam's phase space distribution is manipulated and precision tailored to meet the required beam qualities. On the other hand, all realization of such gymnastics will have to obey accelerator physics principles as well as technological limitations. Recent examples of phase space gymnastics include Emittance exchanges, Phase space exchanges, Emittance partitioning, Seeded FELs and Microbunched beams. The emittance related topics of this list are reviewed in this report. The accelerator physics basis, the optics design principles that provide these phase space manipulations, and the possible applications of these gymnastics, are discussed. This fascinating new field promises to be a powerful tool of the future.

  16. Hamburg Accelerator Conference (2)

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Edmund J.N. [CERN Accelerator School (Switzerland)

    1992-11-15

    From 20-24 July, Hamburg welcomed the Fifteenth International Conference on High Energy Accelerators (HEACC). The HEACC Conference traditionally reviews the status of all major accelerator projects whether they are already running like clockwork, still in the construction phase, or waiting impatiently for financial approval.

  17. Hamburg Accelerator Conference (2)

    International Nuclear Information System (INIS)

    Wilson, Edmund J.N.

    1992-01-01

    From 20-24 July, Hamburg welcomed the Fifteenth International Conference on High Energy Accelerators (HEACC). The HEACC Conference traditionally reviews the status of all major accelerator projects whether they are already running like clockwork, still in the construction phase, or waiting impatiently for financial approval

  18. A microwave inverse Cerenkov Accelerator (MICA)

    International Nuclear Information System (INIS)

    Hirshfield, Jay L.

    1999-01-01

    The objective of this Phase II SBIR research program was to complete the final design originated during Phase I for a prototype Microwave Inverse Cerenkov Accelerator (MICA), to fabricate the-prototype MICA, and to test its performance as an electron accelerator. This report contains details of the design, predictions of accelerator performance, results of cold tests on the MICA structure, and details of the installation of MICA on the Yale Beam Physics Laboratory 6-MeV beamline. Discussion of future work is also included

  19. Magnetic resonance tissue phase mapping demonstrates altered left ventricular diastolic function in children with chronic kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Gimpel, Charlotte; Pohl, Martin [Medical Center - University of Freiburg, Department of General Pediatrics, Adolescent Medicine and Neonatology, Center for Pediatrics, Freiburg (Germany); Jung, Bernd A. [Inselspital Bern, Institute of Diagnostic, Interventional and Pediatric Radiology, Bern (Switzerland); Jung, Sabine [Medical Center - University of Freiburg, Department of Nuclear Medicine, Freiburg (Germany); Brado, Johannes; Odening, Katja E. [University Heart Center Freiburg, Department of Cardiology and Angiology I, Freiburg (Germany); Schwendinger, Daniel [University Children' s Hospital Zurich, Zurich (Switzerland); Burkhardt, Barbara [University Children' s Hospital Zurich, Pediatric Heart Center, Zurich (Switzerland); Geiger, Julia [University Children' s Hospital Zurich, Department of Radiology, Zurich (Switzerland); Northwestern University, Department of Radiology, Chicago, IL (United States); Arnold, Raoul [University Hospital Heidelberg, Department of Pediatric and Congenital Cardiology, Heidelberg (Germany)

    2017-02-15

    Echocardiographic examinations have revealed functional cardiac abnormalities in children with chronic kidney disease. To assess the feasibility of MRI tissue phase mapping in children and to assess regional left ventricular wall movements in children with chronic kidney disease. Twenty pediatric patients with chronic kidney disease (before or after renal transplantation) and 12 healthy controls underwent tissue phase mapping (TPM) to quantify regional left ventricular function through myocardial long (Vz) and short-axis (Vr) velocities at all 3 levels of the left ventricle. Patients and controls (age: 8 years - 20 years) were matched for age, height, weight, gender and heart rate. Patients had higher systolic blood pressure. No patient had left ventricular hypertrophy on MRI or diastolic dysfunction on echocardiography. Fifteen patients underwent tissue Doppler echocardiography, with normal z-scores for mitral early diastolic (V{sub E}), late diastolic (V{sub A}) and peak systolic (V{sub S}) velocities. Throughout all left ventricular levels, peak diastolic Vz and Vr (cm/s) were reduced in patients: Vz{sub base} -10.6 ± 1.9 vs. -13.4 ± 2.0 (P < 0.0003), Vz{sub mid} -7.8 ± 1.6 vs. -11 ± 1.5 (P < 0.0001), Vz{sub apex} -3.8 ± 1.6 vs. -5.3 ± 1.6 (P = 0.01), Vr{sub base} -4.2 ± 0.8 vs. -4.9 ± 0.7 (P = 0.01), Vr{sub mid} -4.7 ± 0.7 vs. -5.4 ± 0.7 (P = 0.01), Vr{sub apex} -4.7 ± 1.4 vs. -5.6 ± 1.1 (P = 0.05). Tissue phase mapping is feasible in children and adolescents. Children with chronic kidney disease show significantly reduced peak diastolic long- and short-axis left ventricular wall velocities, reflecting impaired early diastolic filling. Thus, tissue phase mapping detects chronic kidney disease-related functional myocardial changes before overt left ventricular hypertrophy or echocardiographic diastolic dysfunction occurs. (orig.)

  20. Quasi-phase-matched acceleration of electrons in a corrugated plasma channel

    Directory of Open Access Journals (Sweden)

    S. J. Yoon

    2012-08-01

    Full Text Available A laser pulse propagating in a corrugated plasma channel is composed of spatial harmonics whose phase velocities can be subluminal. The phase velocity of a spatial harmonic can be matched to the speed of a relativistic electron resulting in direct acceleration by the guided laser field in a plasma waveguide and linear energy gain over the interaction length. Here we examine the fully self-consistent interaction of the laser pulse and electron beam using particle-in-cell (PIC simulations. For low electron beam densities, we find that the ponderomotive force of the laser pulse pushes plasma channel electrons towards the propagation axis, which deflects the beam electrons. When the beam density is high, the space charge force of the beam drives the channel electrons off axis, providing collimation of the beam. In addition, we consider a ramped density profile for lowering the threshold energy for trapping in a subluminal spatial harmonic. By using a density ramp, the trapping energy for a normalized vector potential of a_{0}=0.1 is reduced from a relativistic factor γ_{0}=170 to γ_{0}=20.

  1. Prognostic value of regulatory T cells in newly diagnosed chronic myeloid leukemia patients.

    Science.gov (United States)

    Zahran, Asmaa M; Badrawy, Hosny; Ibrahim, Abeer

    2014-08-01

    Chronic myeloid leukemia (CML) is a clonal disease, characterized by a reciprocal t(9, 22) that results in a chimeric BCR/ABL fusion gene. Regulatory T cells (Tregs) constitute the main cell population that enables cancer cells to evade immune surveillance. The purpose of our study was to investigate the level of Tregs in newly diagnosed CML patients and to correlate it with the patients' clinical, laboratory and molecular data. We also aimed to assess the effect of treatment using tyrosine kinase inhibitor (TKI) on Treg levels. Tregs were characterized and quantified by flow cytometry in 63 newly diagnosed CML patients and 40 healthy controls. TKI was used in 45 patients with chronic phase CML, and the response to therapy was correlated with baseline Treg levels. The percentages of Tregs were significantly increased in CML patients compared to the controls. Treg numbers were significantly lower in patients with chronic phase CML versus the accelerated and blast phases, and were significantly lower in patients with complete molecular remission (CMR) compared to those patients without CMR. Tregs may play a role in the maintenance of CML. Moreover, the decrease of their levels in patients with CMR suggests that Tregs might have a clinical value in evaluating the effects of therapy.

  2. Status of MAPA (Modular Accelerator Physics Analysis) and the Tech-X Object-Oriented Accelerator Library

    Science.gov (United States)

    Cary, J. R.; Shasharina, S.; Bruhwiler, D. L.

    1998-04-01

    The MAPA code is a fully interactive accelerator modeling and design tool consisting of a GUI and two object-oriented C++ libraries: a general library suitable for treatment of any dynamical system, and an accelerator library including many element types plus an accelerator class. The accelerator library inherits directly from the system library, which uses hash tables to store any relevant parameters or strings. The GUI can access these hash tables in a general way, allowing the user to invoke a window displaying all relevant parameters for a particular element type or for the accelerator class, with the option to change those parameters. The system library can advance an arbitrary number of dynamical variables through an arbitrary mapping. The accelerator class inherits this capability and overloads the relevant functions to advance the phase space variables of a charged particle through a string of elements. Among other things, the GUI makes phase space plots and finds fixed points of the map. We discuss the object hierarchy of the two libraries and use of the code.

  3. Post-transplant outcome in chronic myeloid leukemia

    International Nuclear Information System (INIS)

    Raza, S.; Ullah, K.; Ahmed, P.; Kamal, M.K.

    2008-01-01

    To determine post-transplant survival in chronic myeloid leukaemia patients undergoing allogeneic stem cell transplant. All patients of chronic myeloid leukaemia in chronic phase having HLA identical donor and age under 55 years, normal hepatic, renal and cardiac functions with good performance status were selected. Patients in accelerated phase or blast crisis, poor performance status, impaired hepatic, renal, cardiac functions or pregnancy were excluded. Survival was calculated from the date of transplant to death or last follow-up according to Kaplan-Meier and Cox (proportional hazard) regression analysis methods. Thirty seven patients with chronic myeloid leukaemia underwent allogeneic stem cell transplant from HLA identical sibling donors. Thirty two patients were male and five were females. Median age of patients was 28 years. All patients and donors were CMV positive. Post-transplant complications encountered were acute GvHD (Grade II-IV) (n=13, 35.1%), chronic GvHD in 18.9% (n=7), Veno Occlusive Disease (VOD) in 5.4% (n=2), acute renal failure in 2.7% (n=1), haemorrhagic cystitis in 2.7% (n=1), bacterial infections in 40.5% (n=15), fungal infections in 16.2% (n=6), CMV infection in 5.4% (n=2), tuberculosis in 5.4% (n=2), Herpes Zoster infection 2.7% (n=1) and relapse in 2.7% (n=1). Mortality was observed in 27% (n=10). Major causes of mortality were GvHD, VOD, septicemia, CMV infection and disseminated Aspergillosis. Overall Disease Free Survival (DFS) was 73% with a median duration of follow-up of 47.4 + 12 months. DFS was 81% in standard risk and 54.5% in high-risk group. Results of allogeneic stem cell transplant in standard risk group CML patients were good and comparable with other international centres, however, results in high-risk CML patients need further improvement, although, number of patients in this group is small. (author)

  4. Monte Carlo simulation of a medical linear accelerator for generation of phase spaces

    International Nuclear Information System (INIS)

    Oliveira, Alex C.H.; Santana, Marcelo G.; Lima, Fernando R.A.; Vieira, Jose W.

    2013-01-01

    Radiotherapy uses various techniques and equipment for local treatment of cancer. The equipment most often used in radiotherapy to the patient irradiation are linear accelerators (Linacs) which produce beams of X-rays in the range 5-30 MeV. Among the many algorithms developed over recent years for evaluation of dose distributions in radiotherapy planning, the algorithms based on Monte Carlo methods have proven to be very promising in terms of accuracy by providing more realistic results. The MC methods allow simulating the transport of ionizing radiation in complex configurations, such as detectors, Linacs, phantoms, etc. The MC simulations for applications in radiotherapy are divided into two parts. In the first, the simulation of the production of the radiation beam by the Linac is performed and then the phase space is generated. The phase space contains information such as energy, position, direction, etc. og millions of particles (photos, electrons, positrons). In the second part the simulation of the transport of particles (sampled phase space) in certain configurations of irradiation field is performed to assess the dose distribution in the patient (or phantom). The objective of this work is to create a computational model of a 6 MeV Linac using the MC code Geant4 for generation of phase spaces. From the phase space, information was obtained to asses beam quality (photon and electron spectra and two-dimensional distribution of energy) and analyze the physical processes involved in producing the beam. (author)

  5. TeV/m nano-accelerator: Investigation on feasibility of CNT-channeling acceleration at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y. M. [Northern Illinois Univ., DeKalb, IL (United States); Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Lumpkin, A. H. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Thurman-Keup, R. M. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-03-23

    The development of high gradient acceleration and tight phase-space control of high power beams is a key element for future lepton and hadron colliders since the increasing demands for higher energy and luminosity significantly raise costs of modern HEP facilities. Atomic channels in crystals are known to consist of 10–100 V/Å potential barriers capable of guiding and collimating a high energy beam providing continuously focused acceleration with exceptionally high gradients (TeV/m). However, channels in natural crystals are only angstrom-size and physically vulnerable to high energy interactions, which has prevented crystals from being applied to high power accelerators. Carbon-based nano-crystals such as carbon-nanotubes (CNTs) and graphenes have a large degree of dimensional flexibility and thermo-mechanical strength, which could be suitable for channeling acceleration of MW beams. Nano-channels of the synthetic crystals can accept a few orders of magnitude larger phase-space volume of channeled particles with much higher thermal tolerance than natural crystals. This study presents the current status of CNT-channeling acceleration research at the Advanced Superconducting Test Accelerator (ASTA) in Fermilab.

  6. An improved phase-control system for superconducting low-velocity accelerating structures

    International Nuclear Information System (INIS)

    Bogaty, J.M.; Clifft, B.E.; Shepard, K.W.; Zinkann, G.P.

    1989-01-01

    Microphonic fluctuations in the rf eigenfrequency of superconducting (SC) slow-wave structures must be compensated by a fast-tuning system in order to control the rf phase. The tuning system must handle a reactive power proportional to the product of the tuning range and the rf energy content of the resonant cavity. The accelerating field level of many of the SC cavities forming the ATLAS linac has been limited by the rf power capacity of the presently used PIN-diode based fast-tuner. A new system has been developed, utilizing PIN diodes operating immersed in liquid nitrogen, with the diodes controlled by a high-voltage VMOS FET driver. The system has operated at reactive power levels above 20 KVA, a factor of four increase over an earlier design. 7 refs., 2 figs

  7. An improved phase-controlled system for superconducting low-velocity accelerating structures

    International Nuclear Information System (INIS)

    Bogaty, J.M.; Clifft, B.E.; Shepard, K.W.; Zinkann, G.P.

    1989-01-01

    Microphonic fluctuations in the RF eigenfrequency of supeconducting (SC) slow-wave structures must be compensated by a fast-tuning system in order to control the RF phase. The tuning system must handle a reactive power proportional to the product of the tuning range and the RF energy content of the resonant cavity. The accelerating field level of many of the SC cavities forming the ATLAS linac has been limited by the RF power capacity of the presently used PIN-diode based fast-tuner. A new system has been developed, utilizing PIN diodes operating immersed in liquid nitrogen, with the diodes controlled by a high-voltage VMOS FET driver. The system has operated at reactive power levels above 20 KVA, a factor of four increase over an earlier design. 7 refs., 2 figs

  8. An improved phase-control system for superconducting low-velocity accelerating structures

    Energy Technology Data Exchange (ETDEWEB)

    Bogaty, J.M.; Clifft, B.E.; Shepard, K.W.; Zinkann, G.P.

    1989-01-01

    Microphonic fluctuations in the rf eigenfrequency of superconducting (SC) slow-wave structures must be compensated by a fast-tuning system in order to control the rf phase. The tuning system must handle a reactive power proportional to the product of the tuning range and the rf energy content of the resonant cavity. The accelerating field level of many of the SC cavities forming the ATLAS linac has been limited by the rf power capacity of the presently used PIN-diode based fast-tuner. A new system has been developed, utilizing PIN diodes operating immersed in liquid nitrogen, with the diodes controlled by a high-voltage VMOS FET driver. The system has operated at reactive power levels above 20 KVA, a factor of four increase over an earlier design. 7 refs., 2 figs.

  9. Observations of the Coronal Mass Ejection with a Complex Acceleration Profile

    Science.gov (United States)

    Reva, A. A.; Kirichenko, A. S.; Ulyanov, A. S.; Kuzin, S. V.

    2017-12-01

    We study the coronal mass ejection (CME) with a complex acceleration profile. The event occurred on 2009 April 23. It had an impulsive acceleration phase, an impulsive deceleration phase, and a second impulsive acceleration phase. During its evolution, the CME showed signatures of different acceleration mechanisms: kink instability, prominence drainage, flare reconnection, and a CME–CME collision. The special feature of the observations is the usage of the TESIS EUV telescope. The instrument could image the solar corona in the Fe 171 Å line up to a distance of 2 {R}ȯ from the center of the Sun. This allows us to trace the CME up to the LASCO/C2 field of view without losing the CME from sight. The onset of the CME was caused by kink instability. The mass drainage occurred after the kink instability. The mass drainage played only an auxiliary role: it decreased the CME mass, which helped to accelerate the CME. The first impulsive acceleration phase was caused by the flare reconnection. We observed the two-ribbon flare and an increase of the soft X-ray flux during the first impulsive acceleration phase. The impulsive deceleration and the second impulsive acceleration phases were caused by the CME–CME collision. The studied event shows that CMEs are complex phenomena that cannot be explained with only one acceleration mechanism. We should seek a combination of different mechanisms that accelerate CMEs at different stages of their evolution.

  10. Chronic sleep reduction in adolescents with Delayed Sleep Phase Disorder and effects of melatonin treatment

    NARCIS (Netherlands)

    van Maanen, Annette; Dewald-Kaufmann, Julia F.; Smits, Marcel G.; Oort, Frans J.; Meijer, Anne Marie

    2013-01-01

    Homeostatic and circadian changes that occur during adolescence can result in chronic sleep reduction. This may particularly be true for adolescents with Delayed Sleep Phase Disorder (DSPD), which is associated with late Dim Light Melatonin Onset (DLMO). This study assessed the influence of

  11. Centrifuge Study of Pilot Tolerance to Acceleration and the Effects of Acceleration on Pilot Performance

    Science.gov (United States)

    Creer, Brent Y.; Smedal, Harald A.; Wingrove, Rodney C.

    1960-01-01

    A research program the general objective of which was to measure the effects of various sustained accelerations on the control performance of pilots, was carried out on the Aviation Medical Acceleration Laboratory centrifuge, U.S. Naval Air Development Center, Johnsville, PA. The experimental setup consisted of a flight simulator with the centrifuge in the control loop. The pilot performed his control tasks while being subjected to acceleration fields such as might be encountered by a forward-facing pilot flying an atmosphere entry vehicle. The study was divided into three phases. In one phase of the program, the pilots were subjected to a variety of sustained linear acceleration forces while controlling vehicles with several different sets of longitudinal dynamics. Here, a randomly moving target was displayed to the pilot on a cathode-ray tube. For each combination of acceleration field and vehicle dynamics, pilot tracking accuracy was measured and pilot opinion of the stability and control characteristics was recorded. Thus, information was obtained on the combined effects of complexity of control task and magnitude and direction of acceleration forces on pilot performance. These tests showed that the pilot's tracking performance deteriorated markedly at accelerations greater than about 4g when controlling a lightly damped vehicle. The tentative conclusion was also reached that regardless of the airframe dynamics involved, the pilot feels that in order to have the same level of control over the vehicle, an increase in the vehicle dynamic stability was required with increases in the magnitudes of the acceleration impressed upon the pilot. In another phase, boundaries of human tolerance of acceleration were established for acceleration fields such as might be encountered by a pilot flying an orbital vehicle. A special pilot restraint system was developed to increase human tolerance to longitudinal decelerations. The results of the tests showed that human tolerance

  12. Comparison of Direct Oral Anticoagulants and Warfarin in the Treatment of Deep Venous Thrombosis in the Chronic Phase.

    Science.gov (United States)

    Wakakura, Shingo; Hara, Fumihiko; Fujino, Tadashi; Hamai, Asami; Ohara, Hiroshi; Kabuki, Takayuki; Harada, Masahiko; Ikeda, Takanori

    2018-01-27

    We assessed the efficacy and safety of direct oral anticoagulants (DOACs) for the treatment of deep venous thrombosis (DVT) in the chronic phase through comparison with conventional warfarin therapy.A total of 807 consecutive patients who were diagnosed with having DVT in the chronic phase were included (484 patients to warfarin therapy and 323 patients to DOAC therapy). The condition of leg veins was assessed 3 to 6 months after starting the therapies by ultrasound examination. Major bleeding and mortality during the therapies were followed-up.There was no significant difference between the two groups in the thrombosis improvement rate (DOAC group: 91.2% versus warfarin group: 88.9%). There was no significant difference between the two groups in major bleeding (DOAC group: 1.8% versus warfarin group: 1.8%). In patients with active cancer, the DOAC group had a borderline higher thrombosis improvement rate than the warfarin group (92.1% versus 80.0%, P = 0.05). The proportion of major bleeding in the patients with active cancer was slightly higher in the warfarin group than in the DOAC group (4.3% versus 2.8%; P = 0.71). Active cancer was not an independent risk factor for major bleeding and recurrence in the DOAC group (OR 2.68, 95% CI 0.51-14.1; P = 0.24 and OR 0.65, 95% CI 0.20-2.07; P = 0.47).In treatment using oral anticoagulants for DVT in the chronic phase, DOACs exhibited equal efficacy and safety as warfarin did. Particularly DOACs appear to be an attractive therapeutic option for cancer-associated DVT in chronic phase, with relatively low anticipated rates of recurrence and major bleeding.

  13. 'Real-life' study of imatinib therapy in chronic phase-chronic myeloid leukemia: A novel retrospective observational longitudinal analysis.

    Science.gov (United States)

    Merante, Serena; Ferretti, Virginia; Elena, Chiara; Calvello, Celeste; Rocca, Barbara; Zappatore, Rita; Cavigliano, Paola; Orlandi, Ester

    2017-01-01

    Imatinib is a cornerstone of treatment of chronic myeloid leukemia. It remains unclear whether transient treatment discontinuation or dose changes affect outcome and this approach has not yet been approved for use outside clinical trials. We conducted a retrospective single-institution observational study to evaluate factors affecting response in 'real-life' clinical practice in 138 chronic myeloid leukemia patients in chronic phase treated with imatinib. We used a novel longitudinal data analytical model, with a generalized estimating equation model, to study BCR-ABL variation according to continuous standard dose, change in dose or discontinuation; BCR-ABL transcript levels were recorded. Treatment history was subdivided into time periods for which treatment was given at constant dosage (total 483 time periods). Molecular and cytogenetic complete response was observed after 154 (32%) and 358 (74%) time periods, respectively. After adjusting for length of time period, no association between dose and cytogenetic complete response rate was observed. There was a significantly lower molecular complete response rate after time periods at a high imatinib dosage. This statistical approach can identify individual patient variation in longitudinal data collected over time and suggests that changes in dose or discontinuation of therapy could be considered in patients with appropriate biological characteristics.

  14. Unlimited electron acceleration in laser-driven plasma waves

    International Nuclear Information System (INIS)

    Katsouleas, T.; Dawson, J.M.

    1983-01-01

    It is shown that the limitation to the energy gain of 2(ω/ω/sub p/) 2 mc 2 of an electron in the laser-plasma beat-wave accelerator can be overcome by imposing a magnetic field of appropriate strength perpendicular to the plasma wave. This accelerates particles parallel to the phase fronts of the accelerating wave which keeps them in phase with it. Arbitrarily large energy is theoretically possible

  15. High brightness electron accelerator

    International Nuclear Information System (INIS)

    Sheffield, R.L.; Carlsten, B.E.; Young, L.M.

    1994-01-01

    A compact high brightness linear accelerator is provided for use, e.g., in a free electron laser. The accelerator has a first plurality of accelerating cavities having end walls with four coupling slots for accelerating electrons to high velocities in the absence of quadrupole fields. A second plurality of cavities receives the high velocity electrons for further acceleration, where each of the second cavities has end walls with two coupling slots for acceleration in the absence of dipole fields. The accelerator also includes a first cavity with an extended length to provide for phase matching the electron beam along the accelerating cavities. A solenoid is provided about the photocathode that emits the electrons, where the solenoid is configured to provide a substantially uniform magnetic field over the photocathode surface to minimize emittance of the electrons as the electrons enter the first cavity. 5 figs

  16. Floating-point-based hardware accelerator of a beam phase-magnitude detector and filter for a beam phase control system in a heavy-ion synchrotron application

    International Nuclear Information System (INIS)

    Samman, F.A.; Pongyupinpanich Surapong; Spies, C.; Glesner, M.

    2012-01-01

    A hardware implementation of an adaptive phase and magnitude detector and filter of a beam-phase control system in a heavy ion synchrotron application is presented in this paper. The main components of the hardware are adaptive LMS (Least-Mean-Square) filters and phase and magnitude detectors. The phase detectors are implemented by using a CORDIC (Coordinate Rotation Digital Computer) algorithm based on 32-bit binary floating-point arithmetic data formats. The floating-point-based hardware is designed to improve the precision of the past hardware implementation that were based on fixed-point arithmetics. The hardware of the detector and the adaptive LMS filter have been implemented on a programmable logic device (FPGA) for hardware acceleration purpose. The ideal Matlab/Simulink model of the hardware and the VHDL model of the adaptive LMS filter and the phase and magnitude detector are compared. The comparison result shows that the output signal of the floating-point based adaptive FIR filter as well as the phase and magnitude detector agree with the expected output signal of the ideal Matlab/Simulink model. (authors)

  17. Accelerated cyclic corrosion tests

    Directory of Open Access Journals (Sweden)

    Prošek T.

    2016-06-01

    Full Text Available Accelerated corrosion testing is indispensable for material selection, quality control and both initial and residual life time prediction for bare and painted metallic, polymeric, adhesive and other materials in atmospheric exposure conditions. The best known Neutral Salt Spray (NSS test provides unrealistic conditions and poor correlation to exposures in atmosphere. Modern cyclic accelerated corrosion tests include intermittent salt spray, wet and dry phases and eventually other technical phases. They are able to predict the material performance in service more correctly as documented on several examples. The use of NSS should thus be restricted for quality control.

  18. Treating the chronic-phase chronic myeloid leukemia patient: which TKI, when to switch and when to stop?

    Science.gov (United States)

    Patel, Ami B; Wilds, Brandon W; Deininger, Michael W

    2017-07-01

    With the discovery of imatinib mesylate nearly 20 years ago, tyrosine kinase inhibitors (TKIs) were found to be effective in chronic myeloid leukemia (CML). TKI therapy has since revolutionized the treatment of CML and has served as a paradigm of success for targeted drug therapy in cancer. Several new TKIs for CML have been approved over the last two decades that exhibit improved potency over imatinib and have different off-target profiles, providing options for individualized therapy selection. Areas covered: Current management of chronic phase CML, including guidance on the sequential use of imatinib and newer-generation TKIs and evolving treatment strategies such as TKI discontinuation. Relevant literature was identified by searching biomedical databases (i.e. PubMed) for primary research material. Expert commentary: Although survival outcomes have drastically improved for CML patients, treatment for CML has grown more complex with the introduction of next-generation TKIs and the advent of treatment-free remissions (TFR). Goals of therapy have shifted accordingly, with increased focus on improving quality of life, managing patient expectations and optimizing patient adherence.

  19. Autobiographical memory and structural brain changes in chronic phase TBI.

    Science.gov (United States)

    Esopenko, Carrie; Levine, Brian

    2017-04-01

    Traumatic brain injury (TBI) is associated with a range of neuropsychological deficits, including attention, memory, and executive functioning attributable to diffuse axonal injury (DAI) with accompanying focal frontal and temporal damage. Although the memory deficit of TBI has been well characterized with laboratory tests, comparatively little research has examined retrograde autobiographical memory (AM) at the chronic phase of TBI, with no prior studies of unselected patients drawn directly from hospital admissions for trauma. Moreover, little is known about the effects of TBI on canonical episodic and non-episodic (e.g., semantic) AM processes. In the present study, we assessed the effects of chronic-phase TBI on AM in patients with focal and DAI spanning the range of TBI severity. Patients and socioeconomic- and age-matched controls were administered the Autobiographical Interview (AI) (Levine, Svoboda, Hay, Winocur, & Moscovitch, 2002) a widely used method for dissociating episodic and semantic elements of AM, along with tests of neuropsychological and functional outcome. Measures of episodic and non-episodic AM were compared with regional brain volumes derived from high-resolution structural magnetic resonance imaging (MRI). Severe TBI (but not mild or moderate TBI) was associated with reduced recall of episodic autobiographical details and increased recall of non-episodic details relative to healthy comparison participants. There were no significant associations between AM performance and neuropsychological or functional outcome measures. Within the full TBI sample, autobiographical episodic memory was associated with reduced volume distributed across temporal, parietal, and prefrontal regions considered to be part of the brain's AM network. These results suggest that TBI-related distributed volume loss affects episodic autobiographical recollection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Six-phase soil heating accelerates VOC extraction from clay soil

    International Nuclear Information System (INIS)

    Gauglitz, P.A.; Roberts, J.S.; Bergsman, T.M.; Caley, S.M.; Heath, W.O.; Miller, M.C.; Moss, R.W.; Schalla, R.; Jarosch, T.R.; Eddy-Dilek, C.A.

    1994-08-01

    Six-Phase Soil Heating (SPSH) was demonstrated as a viable technology for heating low permeability soils containing volatile organic contaminants. Testing was performed as part of the Volatile Organic Compounds in Non-Arid Soils Integrated Demonstration (VOC Non-Arid ID) at the Savannah River Site. The soil at the integrated demonstration site is contaminated with perchloroethylene (PCE) and trichloroethylene (TCE); the highest soil contamination occurs in clay-rich zones that are ineffectively treated by conventional soil vapor extraction due to the very low permeability of the clay. The SPSH demonstration sought to heat the clay zone and enhance the performance of conventional soil vapor extraction. Thermocouples at thirty locations quantified the areal and vertical heating within the treated zone. Soil samples were collected before and after heating to quantify the efficacy of heat-enhanced vapor extraction of PCE and TCE from the clay soil. Samples were taken (essentially every foot) from six wells prior to heating and adjacent to these wells after heating. Results show that contaminant removal from the clay zone was 99.7% (median) within the electrode array. Outside the array where the soil was heated, but to only 50 degrees C, the removal efficiency was 93%, showing that heating accelerated the removal of VOCs from the clay soil. The accelerated remediation resulted from effective heating of the contaminated clay zone by SPSH. The temperature of the clay zone increased to 100 degrees C after 8 days of heating and was maintained near 100 degrees C for 17 days. Electrical heating removed 19,000 gal of water from the soil as steam, with peak removal rate of 1,500 gpd of condensed steam

  1. Chronic headache and comorbidities: a two-phase, population-based, cross-sectional study.

    Science.gov (United States)

    da Silva, Ariovaldo; Costa, Esther Coelho; Gomes, João Bosco; Leite, Frederico Motta; Gomez, Rodrigo Santiago; Vasconcelos, Luiz Paulo; Krymchantowski, Abouch; Moreira, Pedro; Teixeira, Antonio Lucio

    2010-09-01

    Studies using resources of a public family health program to estimate the prevalence of chronic daily headaches (CDH) are lacking. To estimate the 1-year prevalence of CDH, as well as the presence of associated psychiatric and temporomandibular disorders (TMD) comorbidities, on the entire population of a city representative of the rural area of Brazil. This was a cross-sectional, population-based, 2-phase study. In the first phase, health agents interviewed all individuals older than 10 years, in a rural area of Brazil. In the second stage, all individuals who reported headaches on 4 or more days per week were then evaluated by a multidisciplinary team. CDH were classified according to the second edition of the International Classification of Headache Disorders (ICHD-2). Medication overuse headache was diagnosed, as per the ICHD-2, after detoxification trials. Psychiatric comorbidities and TMD were diagnosed based on the DSM-IV and on the Research Diagnostic Criteria for Temporomandibular Disorders criteria, respectively. A total of 1631 subjects participated in the direct interviews. Of them, 57 (3.6%) had CDH. Chronic migraine was the most common of the CDH (21, 36.8%). Chronic tension-type headache (10, 17.5%), medication overuse headache (13, 22.8%) and probable medication overuse headache (10, 17.5%) were also common. Psychiatric disorders were observed in 38 (67.3%) of the CDH subjects. TMD were seen in 33 (58.1)% of them. The prevalence of CDH in the rural area of Brazil is similar to what has been reported in previous studies. A significant proportion of them have psychiatric comorbidities and/or TMD. In this sample, comorbidities were as frequent as reported in convenience samples from tertiary headache centers.

  2. Tuning of External Q And Phase for The Cavities of A Superconducting Linear Accelerator

    CERN Document Server

    Katalev, V V

    2004-01-01

    The RF power required for a certain gradient of a superconducting cavity depends on the beam current and coupling between the cavity and waveguide. The coupling with the cavity may be changed by variation of Qext. Different devices can be used to adjust Qext or phase. In this paper three stub and E-H tuners are compared and their usability for the RF power distribution system for the superconducting accelerator of the European Xray laser and the TESLA linear collider is considered. The tuners were analyzed by using the scattering matrix. Advantages and limitations of the devices are presented.

  3. The use of vapour phase ultra-violet spectroscopy for the analysis of arson accelerants in fire scene debris.

    Science.gov (United States)

    McCurdy, R J; Atwell, T; Cole, M D

    2001-12-01

    A method has been developed for the analysis of arson accelerants in fire scene debris by vapour phase ultra-violet (UV) spectroscopy. The method is rapid, inexpensive, simple to use and is sufficiently sensitive and discriminating to be of use for the analysis of crime scene samples. Application to casework samples is described. On occasion, the method offers additional information to that which can be obtained by gas chromatography-flame ionisation detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS) and represents a useful adjunct to these techniques. In addition, the method offers advantages where the use of GC-MS analysis of arson accelerants in fire scene debris is not a practical proposition.

  4. Accelerators for Society - TIARA 2012 Test Infrastructure and Accelerator Research Area (in Polish)

    CERN Document Server

    Romaniuk, R S

    2013-01-01

    TIARA (Test Infrastructure and Accelerator Research Area - Preparatory Phae) is an European Collaboration of Accelerator Technology, which by running research projects, technical, networks and infrastructural has a duty to integrate the research and technical communities and infrastructures in the global scale of Europe. The Collaboration gathers all research centers with large accelerator infrastructures. Other ones, like universities, are affiliated as associate members. TIARA-PP (preparatory phase) is an European infrastructural project run by this Consortium and realized inside EU-FP7. The paper presents a general overview of TIARA activities, with an introduction containing a portrait of contemporary accelerator technology and a digest of its applications in modern society.

  5. Role of T2 weighted magnetic resonance image in chronic phase of head injured patients

    International Nuclear Information System (INIS)

    Uzura, Masahiko; Taguchi, Yoshio; Watanabe, Hiroyuki; Chiba, Syunmei; Matsuzawa, Motoshi

    2002-01-01

    In neuroimaging studies of head injury, addition of echo planar imaging (EPI) T2-weighted images (WI) to routine MR images has been useful in demonstrating small hemorrhagic lesions as magnetic susceptibility artifacts (MSAs). MSAs are often found in the acute or subacute phases of head injured patients with diffuse axonal injury. We studied MSAs in follow-up MR images of patients with diffuse brain injury and discuss the role of EPI T2-WI in patients with chronic phase of head injured patients. This series consisted of 20 patients with diffuse brain injury diagnosed clinically. Their head CT findings were classified into Diffuse Injury I or II according to the CT classification of Marshall et al. All patients underwent long-term follow-up MR examinations. MR findings in chronic phase were divided into three categories in terms of MSAs: group A, MSAs remaining even after disappearance of small traumatic lesions in both T2-WI and fluid attenuated inversion recovery (FLAIR) images (11 cases); group B, MSA (s) that disappeared in association with disappearance of small traumatic lesions (4 cases); and group C, MSAs that remained but could not be differentiated from non-traumatic lesions such as hemorrhagic lacunae or cavernoma (5 cases). Adding EPI T2-WI to routine MR images can provide useful information in visualizing old traumatic lesions of the brain in patients with diffuse brain injury even if no neuroimaging studies in acute or subacute phase. (author)

  6. The research of the beam phase and energy test system for DTL in the proton accelerator of CSNS

    International Nuclear Information System (INIS)

    Zhao Lei; Liu Shubin; An Qi

    2009-01-01

    China Spallation Neutron Source is now in the process of research and design,in which the proton accelerator is an important part. This beam phase and energy test system imports the signal from the Drift Tube Linac and computes its phase and energy, which is feedback to tune the beam. The signals to be processed here are modulated impulses of high frequency (repetition rate is 352.2 MHz, while the leading edge is only hundreds of ps), and the dynamic range of the amplitude is from 20 mv to 900 mv (peak to peak); therefore, special techniques are required to obtain its phase information. Moreover, to confirm the basic theory of corresponding techniques and evaluate their effects, some simulations are implemented in the platform of Matlab. (authors)

  7. Operation of the graded-β electron test accelerator

    International Nuclear Information System (INIS)

    Fraser, J.S.; McKeown, J.; McMichael, G.E.; Diamond, W.T.

    1976-01-01

    The Electron Test Accelerator has been built to model the behaviour of the high energy portion of a proton linear accelerator which would be suitable for breeding fissile material. The test accelerator and its control systems have been tested at 100% duty factor producing a beam of electrons at 1.5 MeV and currents up to 20 mA where the incident rf power is shared equally between the structure dissipation and the beam loading. The structure has performed satisfactorily in all respects at dissipation power densities up to 5 kW/cell where the mean energy gradient was 1.1 MeV/m. Experiments have been done on the beam loading effects in the coupling of the transmission line to the cavity, the amplitude depression in and phase tilt along the structure, and the phase lag of the structure field. The phase acceptance, the variation of transmission with buncher-accelerator phase shift and the beam energy spread are in qualitative agreement with beam dynamics calculations. (author)

  8. Acceleration of two-phase flow by boiling, 1

    International Nuclear Information System (INIS)

    Hara, Toshitsugu; Uchida, Motokazu; Mitani, Akio; Mori, Yasuo; Hijikata, Kunio.

    1975-01-01

    This paper reports on the experimental results concerning the acceleration mechanism of the liquid used for liquid metal magnetohydrodynamic power generation. The experiment simulated two-component flow by injecting low boiling point liquid (R113) which is not soluble in main high temperature flow (hot water). From the boiling of this two component flow, the relations among the acceleration performance of the liquid, the number and frequency of bubbles generated from liquid drops, and the growth velocity of the bubbles have been investigated. All the injected liquid drops did not necessarily boil even if they were heated above the saturation temperature. The probability of boiling of the liquid drops becomes larger as the temperature difference between two liquids becomes larger. The bubble generation frequency distributed around the mean elapsed time of the liquid drops. The larger temperature difference between two liquids presents sharper distribution. The radius of bubbles increased proportionally to the two-thirds power of the elapsed time and also to two-thirds power of the temperature difference. The liquid acceleration performance by bubbles increased as the bubble generation frequency distribution becomes sharpe. (Tai, I.)

  9. CAS CERN Accelerator School: Fourth general accelerator physics course

    International Nuclear Information System (INIS)

    Turner, S.

    1991-01-01

    The fourth CERN Accelerator School (CAS) basic course on General Accelerator Physics was given at KFA, Juelich, from 17 to 28 September 1990. Its syllabus was based on the previous similar courses held at Gif-sur-Yvette in 1984, Aarhus 1986, and Salamanca 1988, and whose proceedings were published as CERN Reports 85-19, 87-10, and 89-05, respectively. However, certain topics were treated in a different way, improved or extended, while new subjects were introduced. All of these appear in the present proceedings, which include lectures or seminars on the history and applications of accelerators, phase space and emittance, chromaticity, beam-beam effects, synchrotron radiation, radiation damping, tune measurement, transition, electron cooling, the designs of superconducting magnets, ring lattices, conventional RF cavities and ring RF systems, and an introduction to cyclotrons. (orig.)

  10. Chronic inflammation induces telomere dysfunction and accelerates ageing in mice

    NARCIS (Netherlands)

    Jurk, Diana; Wilson, Caroline; Passos, Joao F.; Oakley, Fiona; Correia-Melo, Clara; Greaves, Laura; Saretzki, Gabriele; Fox, Chris; Lawless, Conor; Anderson, Rhys; Hewitt, Graeme; Pender, Sylvia L. F.; Fullard, Nicola; Nelson, Glyn; Mann, Jelena; van de Sluis, Bart; Mann, Derek A.; von Zglinicki, Thomas

    Chronic inflammation is associated with normal and pathological ageing. Here we show that chronic, progressive low-grade inflammation induced by knockout of the nfkb1 subunit of the transcription factor NF-kappa B induces premature ageing in mice. We also show that these mice have reduced

  11. Multi-GPU hybrid programming accelerated three-dimensional phase-field model in binary alloy

    Directory of Open Access Journals (Sweden)

    Changsheng Zhu

    2018-03-01

    Full Text Available In the process of dendritic growth simulation, the computational efficiency and the problem scales have extremely important influence on simulation efficiency of three-dimensional phase-field model. Thus, seeking for high performance calculation method to improve the computational efficiency and to expand the problem scales has a great significance to the research of microstructure of the material. A high performance calculation method based on MPI+CUDA hybrid programming model is introduced. Multi-GPU is used to implement quantitative numerical simulations of three-dimensional phase-field model in binary alloy under the condition of multi-physical processes coupling. The acceleration effect of different GPU nodes on different calculation scales is explored. On the foundation of multi-GPU calculation model that has been introduced, two optimization schemes, Non-blocking communication optimization and overlap of MPI and GPU computing optimization, are proposed. The results of two optimization schemes and basic multi-GPU model are compared. The calculation results show that the use of multi-GPU calculation model can improve the computational efficiency of three-dimensional phase-field obviously, which is 13 times to single GPU, and the problem scales have been expanded to 8193. The feasibility of two optimization schemes is shown, and the overlap of MPI and GPU computing optimization has better performance, which is 1.7 times to basic multi-GPU model, when 21 GPUs are used.

  12. Analysis of FFAG accelerators and the evolution of circular accelerators

    International Nuclear Information System (INIS)

    Laslett, J.

    1961-01-01

    After rapidly comparing circular machines with the linear accelerator and the reasons for the choice of an annular high energy and very high intensity accelerator, recent problems concerning accelerator theory are discussed, with emphasis on their physical character. The FFAG principle. The limit of the energy of FFAG cyclotron. The setting-up and interpreting of mean energy of focusing terms for a spiral FFAG synchrotron. The limiting amplitude stable near the non-linear resonance 2Q z = Q r , as well as the linear coupling resonance of Walkinshaw 2Q z = Q r . The crossed-beam accelerator. The 40 MeV electron model of MURA. Two other parts deal with linear and non-linear methods of injection and extraction using a variable disturbance applied to the magnetic field, as well as to collective effects. The interaction of the beam with the accelerating cavities and the walls. The modification of the phase oscillation equation. The influence of the beams' high frequency fields on the Nielsen longitudinal instability. (author) [fr

  13. The role of ECoG magnitude and phase in decoding position, velocity and acceleration during continuous motor behavior

    Directory of Open Access Journals (Sweden)

    Jiri eHammer

    2013-11-01

    Full Text Available In neuronal population signals, including the electroencephalogram (EEG and electrocorticogram (ECoG, the low-frequency component (LFC is particularly informative about motor behavior and can be used for decoding movement parameters for brain-machine interface (BMI applications. An idea previously expressed, but as of yet not quantitatively tested, is that it is the LFC phase that is the main source of decodable information. To test this issue, we analyzed human ECoG recorded during a game-like, one-dimensional, continuous motor task with a novel decoding method suitable for unfolding magnitude and phase explicitly into a complex-valued, time-frequency signal representation, enabling quantification of the decodable information within the temporal, spatial and frequency domains and allowing disambiguation of the phase contribution from that of the spectral magnitude. The decoding accuracy based only on phase information was substantially (at least 2 fold and significantly higher than that based only on magnitudes for position, velocity and acceleration. The frequency profile of movement-related information in the ECoG data matched well with the frequency profile expected when assuming a close time-domain correlate of movement velocity in the ECoG, e.g., a (noisy copy of hand velocity. No such match was observed with the frequency profiles expected when assuming a copy of either hand position or acceleration. There was also no indication of additional magnitude-based mechanisms encoding movement information in the LFC range. Thus, our study contributes to elucidating the nature of the informative low-frequency component of motor cortical population activity and may hence contribute to improve decoding strategies and BMI performance.

  14. Hemorrhagic intra splenic pseudocyst as a complication of chronic pancreatitis in acute phase - a case report

    International Nuclear Information System (INIS)

    Almeida, Fabiola Assuncao de; Marchiori, Edson; Mello, Walter de Assis; Nogueira, Aline Silva; Sales, Anderson Ribeiro; Martins, Renata Romano; Santos, Tereza Cristina C.R.S. dos

    1999-01-01

    The authors report a case of hemorrhagic intra splenic pseudocyst as a complication of chronic pancreatitis in acute phase. A 43-year-old woman, chronic alcoholic, who had pancreatitis 5 years ago, with symptoms of strong abdominal pain in the epigastrium, nausea and fever. Abdominal sonography showed a lesion contiguous to the spleen and computed tomography demonstrated an heterogeneous lesion of not well defined limits, in the lateral and posterior parts of the spleen. The patient was submitted to Roux-Y cystojejunostomy, he does not present any symptoms at the moment, and is undergoing clinical control. (author)

  15. Dynamics and acceleration in linear structures

    International Nuclear Information System (INIS)

    Le Duff, J.

    1985-06-01

    Basic methods of linear acceleration are reviewed. Both cases of non relativistic and ultra relativistic particles are considered. Induction linac, radiofrequency quadrupole are mentioned. Fundamental parameters of accelerating structures are recalled; they are transit time factor, shunt impedance, quality factor and stored energy, phase velocity and group velocity, filling time, space harmonics in loaded waveguides. Energy gain in linear accelerating structures is considered through standing wave structures and travelling wave structures. Then particle dynamics in linear accelerators is studied: longitudinal motion, transverse motion and dynamics in RFQ

  16. Cytokines and T-Lymphocute count in patients in the acute and chronic phases of Bartonella bacilliformis infection in an endemic area in peru: a pilot study

    Directory of Open Access Journals (Sweden)

    Erick Huarcaya

    2011-06-01

    Full Text Available Human Bartonellosis has an acute phase characterized by fever and hemolytic anemia, and a chronic phase with bacillary angiomatosis-like lesions. This cross-sectional pilot study evaluated the immunology patterns using pre- and post-treatment samples in patients with Human Bartonellosis. Patients between five and 60 years of age, from endemic areas in Peru, in the acute or chronic phases were included. In patients in the acute phase of Bartonellosis a state of immune peripheral tolerance should be established for persistence of the infection. Our findings were that elevation of the anti-inflammatory cytokine IL-10 and numeric abnormalities of CD4+ and CD8+ T-Lymphocyte counts correlated significantly with an unfavorable immune state. During the chronic phase, the elevated levels of IFN-γ and IL-4 observed in our series correlated with previous findings of endothelial invasion of B. henselae in animal models.

  17. Cytokines and T-Lymphocute count in patients in the acute and chronic phases of Bartonella bacilliformis infection in an endemic area in peru: a pilot study.

    Science.gov (United States)

    Huarcaya, Erick; Best, Ivan; Rodriguez-Tafur, Juan; Maguiña, Ciro; Solórzano, Nelson; Menacho, Julio; Lopez De Guimaraes, Douglas; Chauca, Jose; Ventosilla, Palmira

    2011-01-01

    Human Bartonellosis has an acute phase characterized by fever and hemolytic anemia, and a chronic phase with bacillary angiomatosis-like lesions. This cross-sectional pilot study evaluated the immunology patterns using pre- and post-treatment samples in patients with Human Bartonellosis. Patients between five and 60 years of age, from endemic areas in Peru, in the acute or chronic phases were included. In patients in the acute phase of Bartonellosis a state of immune peripheral tolerance should be established for persistence of the infection. Our findings were that elevation of the anti-inflammatory cytokine IL-10 and numeric abnormalities of CD4(+) and CD8(+) T-Lymphocyte counts correlated significantly with an unfavorable immune state. During the chronic phase, the elevated levels of IFN-γ and IL-4 observed in our series correlated with previous findings of endothelial invasion of B. henselae in animal models.

  18. Plasma Density Tapering for Laser Wakefield Acceleration of Electrons and Protons

    International Nuclear Information System (INIS)

    Ting, A.; Gordon, D.; Kaganovich, D.; Sprangle, P.; Helle, M.; Hafizi, B.

    2010-01-01

    Extended acceleration in a Laser Wakefield Accelerator can be achieved by tailoring the phase velocity of the accelerating plasma wave, either through profiling of the density of the plasma or direct manipulation of the phase velocity. Laser wakefield acceleration has also reached a maturity that proton acceleration by wakefield could be entertained provided we begin with protons that are substantially relativistic, ∼1 GeV. Several plasma density tapering schemes are discussed. The first scheme is called ''bucket jumping'' where the plasma density is abruptly returned to the original density after a conventional tapering to move the accelerating particles to a neighboring wakefield period (bucket). The second scheme is designed to specifically accelerate low energy protons by generating a nonlinear wakefield in a plasma region with close to critical density. The third scheme creates a periodic variation in the phase velocity by beating two intense laser beams with laser frequency difference equal to the plasma frequency. Discussions and case examples with simulations are presented where substantial acceleration of electrons or protons could be obtained.

  19. Current approach to the treatment of chronic myeloid leukaemia.

    Science.gov (United States)

    Pasic, Ivan; Lipton, Jeffrey H

    2017-04-01

    Of all the cancers, chronic myeloid leukaemia (CML) has witnessed the most rapid evolution of the therapeutic milieu in recent decades. The introduction of tyrosine kinase inhibitors (TKIs) as a therapeutic option has profoundly changed patient experience and outcome. The availability of multiple new highly effective therapies has increasingly underscored the importance of a good understanding of the underlying pathophysiological basis in CML, as well as patient-specific factors in choosing the right treatment for every individual. The treatment of CML has migrated in many jurisdictions from the office of a highly specialized malignant hematologist to the general hematologist or even a general practitioner. The goal of this review is to offer an overview of the modern approach to the treatment of CML, with an emphasis on chronic phase (CP) CML, including both TKI-based therapies such as imatinib, dasatinib, nilotinib, bosutinib and ponatinib, and non-TKI medications, such as omacetaxine. We discuss evidence behind each drug, most common and material adverse reactions and outline how this information can be used in selecting the right drug for the right patient. We also discuss evidence as it relates to other therapies, including stem cell transplant (SCT), and patients in accelerated (AP) and blastic phase (BP). Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Comparison of parasite loads in serum and blood samples from patients in acute and chronic phases of Chagas disease.

    Science.gov (United States)

    Hernández, Carolina; Teherán, Aníbal; Flórez, Carolina; Ramírez, Juan David

    2018-04-17

    Molecular methods have been developed for the detection and quantification of Trypanosoma cruzi DNA in blood samples from patients with Chagas disease. However, aspects of sample processing necessary for quantitative real-time PCR (qPCR), such as the addition of guanidine hydrochloride to whole blood samples, may limit timely access to molecular diagnosis. We analysed 169 samples from serum and guanidine-EDTA blood (GEB) obtained from patients in acute and chronic phases of Chagas disease. We applied qPCR targeted to the satellite DNA region. Finally, we compared the parasite loads and cycle of threshold values of the qPCR. The results confirmed the usefulness of serum samples for the detection and quantification of parasite DNA in patients with Chagas disease, especially in the acute phase. However, the parasite loads detected in serum samples from patients in the chronic phase were lower than those detected in GEB samples. The epidemiological implications of the findings are herein discussed.

  1. Preferential acceleration in collisionless supernova shocks

    International Nuclear Information System (INIS)

    Hainebach, K.; Eichler, D.; Schramm, D.

    1979-01-01

    The preferential acceleration and resulting cosmic ray abundance enhancements of heavy elements (relative to protons) are calculated in the collisionless supernova shock acceleration model described by Eichler in earlier work. Rapidly increasing enhancements up to several tens times solar ratios are obtained as a function of atomic weight over charge at the time of acceleration. For material typical of hot phase interstellar medium, good agreement is obtained with the observed abundance enhancements

  2. Considering baseline factors and early response rates to optimize therapy for chronic myeloid leukemia in chronic phase.

    Science.gov (United States)

    Akard, Luke P; Bixby, Dale

    2016-05-01

    Multiple BCR-ABL tyrosine kinase inhibitors (TKIs) are available for the treatment of chronic myeloid leukemia in chronic phase (CML-CP), and several baseline and on-treatment predictive factors have been identified that can be used to help guide TKI selection for individual patients. In particular, early molecular response (EMR; BCR-ABL ≤10% on the International Scale at 3 months) has become an accepted benchmark for evaluating whether patients with CML-CP are responding optimally to frontline TKI therapy. Failure to achieve EMR is considered an inadequate initial response according to the National Comprehensive Cancer Network guidelines and a warning response according to the European LeukemiaNet recommendations. Here we review data supporting the importance of achieving EMR for improving patients' long-term outcomes and discuss key considerations for selecting a frontline TKI in light of these data. Because a higher proportion of patients achieve EMR with second-generation TKIs such as nilotinib and dasatinib than with imatinib, these TKIs may be preferable for many patients, particularly those with known negative prognostic factors at baseline. We also discuss other considerations for frontline TKI choice, including toxicities, cost-effectiveness, and the emerging goals of deep molecular response and treatment-free remission.

  3. Multi-beam linear accelerator EVT

    Energy Technology Data Exchange (ETDEWEB)

    Teryaev, Vladimir E., E-mail: vladimir_teryaev@mail.ru [Omega-P, Inc., New Haven, CT 06510 (United States); Kazakov, Sergey Yu. [Fermilab, Batavia, IL 60510 (United States); Hirshfield, Jay L. [Omega-P, Inc., New Haven, CT 06510 (United States); Yale University, New Haven, CT 06511 (United States)

    2016-09-01

    A novel electron multi-beam accelerator is presented. The accelerator, short-named EVT (Electron Voltage Transformer) belongs to the class of two-beam accelerators. It combines an RF generator and essentially an accelerator within the same vacuum envelope. Drive beam-lets and an accelerated beam are modulated in RF modulators and then bunches pass into an accelerating structure, comprising uncoupled with each other and inductive tuned cavities, where the energy transfer from the drive beams to the accelerated beam occurs. A phasing of bunches is solved by choice correspond distances between gaps of the adjacent cavities. Preliminary results of numerical simulations and the initial specification of EVT operating in S-band, with a 60 kV gun and generating a 2.7 A, 1.1 MV beam at its output is presented. A relatively high efficiency of 67% and high design average power suggest that EVT can find its use in industrial applications.

  4. Phase and Frequency Locked Magnetrons for SRF Sources

    International Nuclear Information System (INIS)

    Neubauer, M.; Johnson, R.P.; Popovic, M.; Moretti, A.

    2009-01-01

    Magnetrons are low-cost highly-efficient microwave sources, but they have several limitations, primarily centered about the phase and frequency stability of their output. When the stability requirements are low, such as for medical accelerators or kitchen ovens, magnetrons are the very efficient power source of choice. But for high energy accelerators, because of the need for frequency and phase stability - proton accelerators need 1-2 degrees source phase stability, and electron accelerators need .1-.2 degrees of phase stability - they have rarely been used. We describe a novel variable frequency cavity technique which will be utilized to phase and frequency lock magnetrons.

  5. Virtual mass effects in two-phase flow. Topical report

    International Nuclear Information System (INIS)

    Cheng, L.Y.; Drew, D.A.; Lahey, R.T. Jr.

    1978-03-01

    The effect of virtual mass on phase separation during the acceleration of a two-phase mixture was studied. Virtual mass can be regarded as an induced inertia on the dispersed phase which is accelerating relative to the continuous phase, and it was found that the virtual mass acceleration is objective, implying an invariance with respect to reference frame. An objective form of the virtual acceleration was derived and required parameters were determined for limiting cases. Analyses determined that experiments on single bubble nozzle/diffuser flow cannot readily discriminate between various virtual mass acceleration models

  6. A theoretical investigation of the collective acceleration of cluster ions with accelerated potential waves

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Enjoji, Hiroshi; Kawaguchi, Motoichi; Noritake, Toshiya

    1984-01-01

    A theoretical treatment of the acceleration of cluster ions for additional heating of fusion plasma using the trapping effect in an accelerated potential wave is described. The conceptual design of the accelerator is the same as that by Enjoji, and the potential wave used is sinusoidal. For simplicity, collisions among cluster ions and the resulting breakups are neglected. The masses of the cluster ions are specified to range from 100 m sub(D) to 1000 m sub(D) (m sub(D): mass of a deuterium atom). Theoretical treatment is carried out only for the injection velocity which coincides with the phase velocity of the applied wave at the entrance of the accelerator. An equation describing the rate for successful acceleration of ions with a certain mass is deduced for the continuous injection of cluster ions. Computation for a typical mass distribution shows that more than 70% of the injected particles are effectively accelerated. (author)

  7. Ion optics for accelerators

    International Nuclear Information System (INIS)

    Enge, H.A.

    1974-01-01

    A review is given of ion-optic devices used in particle accelerators, including electrostatic lenses, magnetic quadrupoles, and deflecting magnets. Tube focusing in dc accelerators is also treated, and a novel scheme for shaping the electrodes to produce strong focusing is described. The concepts of emittance (phase space) and emittance conservation are briefly discussed. Chromatic and spatial aberrations are introduced, and it is shown how they can be calculated and sometimes substantially reduced. Some examples are given

  8. PTCH1 is a reliable marker for predicting imatinib response in chronic myeloid leukemia patients in chronic phase.

    Directory of Open Access Journals (Sweden)

    Juan M Alonso-Dominguez

    Full Text Available Patched homolog 1 gene (PTCH1 expression and the ratio of PTCH1 to Smoothened (SMO expression have been proposed as prognostic markers of the response of chronic myeloid leukemia (CML patients to imatinib. We compared these measurements in a realistic cohort of 101 patients with CML in chronic phase (CP using a simplified qPCR method, and confirmed the prognostic power of each in a competing risk analysis. Gene expression levels were measured in peripheral blood samples at diagnosis. The PTCH1/SMO ratio did not improve PTCH1 prognostic power (area under the receiver operating characteristic curve 0.71 vs. 0.72. In order to reduce the number of genes to be analyzed, PTCH1 was the selected measurement. High and low PTCH1 expression groups had significantly different cumulative incidences of imatinib failure (IF, which was defined as discontinuation of imatinib due to lack of efficacy (5% vs. 25% at 4 years, P = 0.013, probabilities of achieving a major molecular response (81% vs. 53% at first year, P = 0.02, and proportions of early molecular failure (14% vs. 43%, P = 0.015. Every progression to an advanced phase (n = 3 and CML-related death (n = 2 occurred in the low PTCH1 group (P<0.001 for both comparisons. PTCH1 was an independent prognostic factor for the prediction of IF. We also validated previously published thresholds for PTCH1 expression. Therefore, we confirmed that PTCH1 expression can predict the imatinib response in CML patients in CP by applying a more rigorous statistical analysis. Thus, PTCH1 expression is a promising molecular marker for predicting the imatinib response in CML patients in CP.

  9. Chronic radiation-induced leukemogenesis: alterations of hematopoietic progenitor repair functions during preclinical phases

    International Nuclear Information System (INIS)

    Seed, T.M.; Kaspar, L.V.; Grdina, D.J.; Frazier, M.E.

    1987-01-01

    Chronic exposure to low daily doses of whole-body gamma irradiation elicits a high incidence of myeloid leukemia (ML) and related myeloproliferative diseases (MPD) in beagles. Previously, the authors identified and partially characterized a four-phase sequence of evolving MPD as a consequence of chronic radiation exposure. With a focus on preclinical alterations in granulocyte/monocyte-committed stem cells, they have identified two critical events in the process: (i) an early event, involving the coupling of acquired radioresistance of the stem cell with renewed proliferative capacity; and (ii) a late event, involving acquired autocrine functions and associated change in stem cell clonality. In terms of the early event, repair-associated parameters are currently being examined on the cellular level by both split-dose and low dose-rate-type assays with survival enhancement used as the measured end point. On the molecular level, these parameters are examined by microfluorometric alkaline elution assays with DNA damage and repair used as end points

  10. Operational experience of the ATLAS accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Den Hartog, P K; Bogaty, J M; Bollinger, L M; Clifft, B E; Craig, S L; Harden, R E; Markovich, P; Munson, F H; Nixon, J M; Pardo, R C; Phillips, D R; Shepard, K W; Tilbrook, I R; Zinkmann, G P [Argonne National Lab., IL (USA). Physics Div.

    1990-02-01

    The ATLAS accelerator consists of a HVEC model FN tandem accelerator injecting into a linac of independently-phased niobium superconducting resonators. The accelerator provides beams with masses 6 {le} A {le} 127 and with energies ranging up to 20 MeV/A for the lightest ions and 4 MeV/A for the heaviest ions. Portions of the linac have been in operation since 1978 and, over the last decade, more than 35000 h of operating experience have been accumulated. The long-term stability of niobium resonators, and their feasibility for use in heavy-ion accelerators is now well established. (orig.).

  11. Physics design of an accelerator for an accelerator-driven subcritical system

    Directory of Open Access Journals (Sweden)

    Zhihui Li

    2013-08-01

    Full Text Available An accelerator-driven subcritical system (ADS program was launched in China in 2011, which aims to design and build an ADS demonstration facility with the capability of more than 1000 MW thermal power in multiple phases lasting about 20 years. The driver linac is defined to be 1.5 GeV in energy, 10 mA in current and in cw operation mode. To meet the extremely high reliability and availability, the linac is designed with much installed margin and fault tolerance, including hot-spare injectors and local compensation method for key element failures. The accelerator complex consists of two parallel 10-MeV injectors, a joint medium-energy beam transport line, a main linac, and a high-energy beam transport line. The superconducting acceleration structures are employed except for the radio frequency quadrupole accelerators (RFQs which are at room temperature. The general design considerations and the beam dynamics design of the driver linac complex are presented here.

  12. Prompt acceleration of ions by oblique turbulent shocks in solar flares

    Science.gov (United States)

    Decker, R. B.; Vlahos, L.

    1985-01-01

    Solar flares often accelerate ions and electrons to relativistic energies. The details of the acceleration process are not well understood, but until recently the main trend was to divide the acceleration process into two phases. During the first phase elctrons and ions are heated and accelerated up to several hundreds of keV simultaneously with the energy release. These mildly relativistic electrons interact with the ambient plasma and magnetic fields and generate hard X-ray and radio radiation. The second phase, usually delayed from the first by several minutes, is responsible for accelerating ions and electrons to relativistic energies. Relativistic electrons and ions interact with the solar atmosphere or escape from the Sun and generate gamma ray continuum, gamma ray line emission, neutron emission or are detected in space by spacecraft. In several flares the second phase is coincident with the start of a type 2 radio burst that is believed to be the signature of a shock wave. Observations from the Solar Maximum Mission spacecraft have shown, for the first time, that several flares accelerate particles to all energies nearly simultaneously. These results posed a new theoretical problem: How fast are shocks and magnetohydrodynamic turbulence formed and how quickly can they accelerate ions to 50 MeV in the lower corona? This problem is discussed.

  13. Prompt acceleration of ions by oblique turbulent shocks in solar flares

    International Nuclear Information System (INIS)

    Decker, R.B.; Vlahos, L.

    1985-01-01

    Solar flares often accelerate ions and electrons to relativistic energies. The details of the acceleration process are not well understood, but until recently the main trend was to divide the acceleration process into two phases. During the first phase elctrons and ions are heated and accelerated up to several hundreds of keV simultaneously with the energy release. These mildly relativistic electrons interact with the ambient plasma and magnetic fields and generate hard x-ray and radio radiation. The second phase, usually delayed from the first by several minutes, is responsible for accelerating ions and electrons to relativistic energies. Relativistic electrons and ions interact with the solar atmosphere or escape from the Sun and generate gamma ray continuum, gamma ray line emission, neutron emission or are detected in space by spacecraft. In several flares the second phase is coincident with the start of a type 2 radio burst that is believed to be the signature of a shock wave. Observations from the Solar Maximum Mission spacecraft have shown, for the first time, that several flares accelerate particles to all energies nearly simultaneously. These results posed a new theoretical problem: How fast are shocks and magnetohydrodynamic turbulence formed and how quickly can they accelerate ions to 50 MeV in the lower corona. This problem is discussed

  14. Radiation shielding technology development for proton linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ouk; Lee, Y. O.; Cho, Y. S. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, M. H.; Sin, M. W.; Park, B. I. [Kyunghee Univ., Seoul (Korea, Republic of)] [and others

    2005-09-01

    This report was presented as an output of 2-year project of the first phase Proton Engineering Frontier Project(PEFP) on 'Radiation Shielding Technology Development for Proton Linear Accelerator' for 20/100 MeV accelerator beam line and facility. It describes a general design concept, provision and update of basic design data, and establishment of computer code system. It also includes results of conceptual and preliminary designs of beam line, beam dump and beam facilities as well as an analysis of air-activation inside the accelerator equipment. This report will guides the detailed shielding design and production of radiation safety analysis report scheduled in the second phase project.

  15. Nonponderomotive electron acceleration in ultrashort surface-plasmon fields

    Energy Technology Data Exchange (ETDEWEB)

    Racz, Peter; Dombi, Peter [Wigner Research Centre for Physics, Konkoly-Thege M. ut 29-33, H-1121 Budapest (Hungary)

    2011-12-15

    We investigate the nonponderomotive nature of ultrafast plasmonic electron acceleration in strongly decaying electromagnetic fields generated by few-cycle and single-cycle femtosecond laser pulses. We clearly identify the conditions contributing to nonponderomotive acceleration and establish fundamental scaling laws and carrier-envelope phase effects. These all-optically accelerated compact, femtosecond electron sources can be utilized in contemporary ultrafast methods.

  16. Compact multi-energy electron linear accelerators

    International Nuclear Information System (INIS)

    Tanabe, E.; Hamm, R.W.

    1985-01-01

    Two distinctly different concepts that have been developed for compact multi-energy, single-section, standing-wave electron linear accelerator structures are presented. These new concepts, which utilize (a) variable nearest neighbor couplings and (b) accelerating field phase switching, provide the capability of continuously varying the electron output energy from the accelerator without degrading the energy spectrum. These techniques also provide the means for continuously varying the energy spectrum while maintaining a given average electron energy, and have been tested successfully with several accelerators of length from 0.1 m to 1.9 m. Theoretical amd experimental results from these accelerators, and demonstrated applications of these techniques to medical and industrial linear accelerator technology will be described. In addition, possible new applications available to research and industry from these techniques are presented. (orig.)

  17. Superconducting accelerator magnet design

    International Nuclear Information System (INIS)

    Wolff, S.

    1994-01-01

    Superconducting dipoles, quadrupoles and correction magnets are necessary to achieve the high magnetic fields required for big accelerators presently in construction or in the design phase. Different designs of superconducting accelerator magnets are described and the designs chosen at the big accelerator laboratories are presented. The most frequently used cosθ coil configuration is discussed in detail. Approaches for calculating the magnetic field quality including coil end fields are presented. Design details of the cables, coils, mechanical structures, yokes, helium vessels and cryostats including thermal radiation shields and support structures used in superconducting magnets are given. Necessary material properties are mentioned. Finally, the main results of magnetic field measurements and quench statistics are presented. (orig.)

  18. Stochastic shock response spectrum decomposition method based on probabilistic definitions of temporal peak acceleration, spectral energy, and phase lag distributions of mechanical impact pyrotechnic shock test data

    Science.gov (United States)

    Hwang, James Ho-Jin; Duran, Adam

    2016-08-01

    Most of the times pyrotechnic shock design and test requirements for space systems are provided in Shock Response Spectrum (SRS) without the input time history. Since the SRS does not describe the input or the environment, a decomposition method is used to obtain the source time history. The main objective of this paper is to develop a decomposition method producing input time histories that can satisfy the SRS requirement based on the pyrotechnic shock test data measured from a mechanical impact test apparatus. At the heart of this decomposition method is the statistical representation of the pyrotechnic shock test data measured from the MIT Lincoln Laboratory (LL) designed Universal Pyrotechnic Shock Simulator (UPSS). Each pyrotechnic shock test data measured at the interface of a test unit has been analyzed to produce the temporal peak acceleration, Root Mean Square (RMS) acceleration, and the phase lag at each band center frequency. Maximum SRS of each filtered time history has been calculated to produce a relationship between the input and the response. Two new definitions are proposed as a result. The Peak Ratio (PR) is defined as the ratio between the maximum SRS and the temporal peak acceleration at each band center frequency. The ratio between the maximum SRS and the RMS acceleration is defined as the Energy Ratio (ER) at each band center frequency. Phase lag is estimated based on the time delay between the temporal peak acceleration at each band center frequency and the peak acceleration at the lowest band center frequency. This stochastic process has been applied to more than one hundred pyrotechnic shock test data to produce probabilistic definitions of the PR, ER, and the phase lag. The SRS is decomposed at each band center frequency using damped sinusoids with the PR and the decays obtained by matching the ER of the damped sinusoids to the ER of the test data. The final step in this stochastic SRS decomposition process is the Monte Carlo (MC

  19. Low-velocity superconducting accelerating structures

    International Nuclear Information System (INIS)

    Delayen, J.R.

    1990-01-01

    The present paper reviews the status of RF superconductivity as applied to low-velocity accelerating properties. Heavy-ion accelerators must accelerate efficiently particles which travel at a velocity much smaller than that of light particles, whose velocity changes along accelerator, and also different particles which have different velocity profiles. Heavy-ion superconducting accelerators operate at frequencies which are lower than high-energy superconducting accelerators. The present paper first discusses the basic features of heavy-ion superconducting structures and linacs. Design choices are then addressed focusing on structure geometry, materials, frequency, phase control, and focusing. The report also gives an outline of the status of superconducting booster projects currently under way at the Argonne National Laboratory, SUNY Stony Brook, Weizmann Institute, University of Washington, Florida State, Saclay, Kansas State, Daresbury, Japanese Atomic Energy Research Institute, Legnaro, Bombay, Sao Paulo, ANU (Canberra), and Munich. Recent developments and future prospects are also described. (N.K.) 68 refs

  20. Heavy ion accelerating structure

    International Nuclear Information System (INIS)

    Pottier, Jacques.

    1977-01-01

    The heavy ion accelerating structure concerned in this invention is of the kind that have a resonance cavity inside which are located at least two longitudinal conducting supports electrically connected to the cavity by one of their ends in such a way that they are in quarter-wavelength resonance and in phase opposition. Slide tubes are electrically connected alternatively to one or the other of the two supports, they being electrically connected respectively to one or the other end of the side wall of the cavity. The feature of the structure is that it includes two pairs of supports symmetrically placed with respect to the centre line of the cavity, the supports of one pair fitted overhanging being placed symmetrically with respect to the centre line of the cavity, each slide tube being connected to the two supports of one pair. These support are connected to the slide wall of the cavity by an insulator located at their electrically free end. The accelerator structure composed of several structures placed end to end, the last one of which is fed by a high frequency field of adjustable amplitude and phase, enables a heavy ion linear accelerator to be built [fr

  1. Towards external injection in laser wakefield acceleration

    NARCIS (Netherlands)

    Stragier, X.F.D.

    2011-01-01

    In laser wakefield acceleration (LWA) a plasma wave is driven by a high intensity ultra short laser pulse and the longitudinal electric fields in the plasma wave are used to accelerate electron bunches. Electrons with an appropriate kinetic energy, injected on the right phase of the plasma wave, get

  2. Operational experience of the ATLAS accelerator

    International Nuclear Information System (INIS)

    Den Hartog, P.K.; Bogaty, J.M.; Bollinger, L.M.

    1989-01-01

    The ATLAS accelerator consists of a HVEC model FN tandem accelerator injecting into a linac of independently-phased niobium superconducting resonators. The accelerator provides beams with masses from 6≤A≤127 and with energies ranging up to 20 MeV/A for the lightest ions and 4 MeV/A for the heaviest ions. Portions of the linac have been in operation since 1978 and, over the last decade, more than 35,000 hours of operating experience have been accumulated. The long-term stability of niobium resonators, and their feasibility for use in heavy-ion accelerators is now well established. 11 refs., 3 figs., 1 tab

  3. Multi-Mode Cavity Accelerator Structure

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yong [Yale Univ., New Haven, CT (United States); Hirshfield, Jay Leonard [Omega-P R& D, Inc., New Haven, CT (United States)

    2016-11-10

    This project aimed to develop a prototype for a novel accelerator structure comprising coupled cavities that are tuned to support modes with harmonically-related eigenfrequencies, with the goal of reaching an acceleration gradient >200 MeV/m and a breakdown rate <10-7/pulse/meter. Phase I involved computations, design, and preliminary engineering of a prototype multi-harmonic cavity accelerator structure; plus tests of a bimodal cavity. A computational procedure was used to design an optimized profile for a bimodal cavity with high shunt impedance and low surface fields to maximize the reduction in temperature rise ΔT. This cavity supports the TM010 mode and its 2nd harmonic TM011 mode. Its fundamental frequency is at 12 GHz, to benchmark against the empirical criteria proposed within the worldwide High Gradient collaboration for X-band copper structures; namely, a surface electric field Esurmax< 260 MV/m and pulsed surface heating ΔTmax< 56 °K. With optimized geometry, amplitude and relative phase of the two modes, reductions are found in surface pulsed heating, modified Poynting vector, and total RF power—as compared with operation at the same acceleration gradient using only the fundamental mode.

  4. Multi-Mode Cavity Accelerator Structure

    International Nuclear Information System (INIS)

    Jiang, Yong; Hirshfield, Jay Leonard

    2016-01-01

    This project aimed to develop a prototype for a novel accelerator structure comprising coupled cavities that are tuned to support modes with harmonically-related eigenfrequencies, with the goal of reaching an acceleration gradient >200 MeV/m and a breakdown rate <10"-"7/pulse/meter. Phase I involved computations, design, and preliminary engineering of a prototype multi-harmonic cavity accelerator structure; plus tests of a bimodal cavity. A computational procedure was used to design an optimized profile for a bimodal cavity with high shunt impedance and low surface fields to maximize the reduction in temperature rise Δ T. This cavity supports the TM010 mode and its 2nd harmonic TM011 mode. Its fundamental frequency is at 12 GHz, to benchmark against the empirical criteria proposed within the worldwide High Gradient collaboration for X-band copper structures; namely, a surface electric field E_s_u_r"m"a"x< 260 MV/m and pulsed surface heating Δ T"m"a"x< 56 °K. With optimized geometry, amplitude and relative phase of the two modes, reductions are found in surface pulsed heating, modified Poynting vector, and total RF power - as compared with operation at the same acceleration gradient using only the fundamental mode.

  5. TIARA: Toward accelerator R&D coordination

    CERN Multimedia

    Anaïs Schaeffer

    2011-01-01

    The preparatory phase of the TIARA (Test Infrastructure and Accelerator Research Area) project has begun. In January, members from 11 research institutes in 8 European countries began a three-year collaboration intended to enhance, improve and structure R&D efforts in the area of accelerator science and technology in Europe.   Partly funded by the European Commission under its Seventh Framework Programme (FP7), the TIARA project is being coordinated by the CEA (Commissariat à l’Énergie Atomique et aux Energies Alternatives). “The aim of the project is to arrive at an organisational structure that will provide coordination for R&D efforts and associated infrastructures in the field of particle accelerators in Europe,” explains the CEA’s Céline Tanguy, project coordinator assistant. “The new structure, which we hope will be a durable one, will be set up at the end of the project’s preparatory phase....

  6. The effect of laser pulse parameters and initial phase on the acceleration of electrons in a vacuum

    International Nuclear Information System (INIS)

    Singh, Kunwar Pal; Gupta, Devki Nandan; Malik, Hitendra K

    2008-01-01

    Laser driven acceleration of electrons lying along the axis of the laser has been studied. We have considered a linearly polarized laser pulse. The quiver amplitude causes electrons to escape from the pulse. The energy gained by the electrons peaks for a suitable value of laser spot size. The value of a suitable laser spot size increases with laser intensity and initial electron energy. The energy gained by the electron depends upon its initial position with respect to the laser pulse. The electrons close to the pulse peak with initial phase π/2 are scattered least and gain higher energy. The electrons close to the leading edge of the pulse gain sufficient energy for a short laser pulse and the effect of initial phase is not important. A suitable value of laser spot size can be estimated from this study

  7. Flux Rope Acceleration and Enhanced Magnetic Reconnection Rate

    International Nuclear Information System (INIS)

    C.Z. Cheng; Y. Ren; G.S. Choe; Y.-J. Moon

    2003-01-01

    A physical mechanism of flares, in particular for the flare rise phase, has emerged from our 2-1/2-dimensional resistive MHD simulations. The dynamical evolution of current-sheet formation and magnetic reconnection and flux-rope acceleration subject to continuous, slow increase of magnetic shear in the arcade are studied by employing a non-uniform anomalous resistivity in the reconnecting current sheet under gravity. The simulation results directly relate the flux rope's accelerated rising motion with an enhanced magnetic reconnection rate and thus an enhanced reconnection electric field in the current sheet during the flare rise phase. The simulation results provide good quantitative agreements with observations of the acceleration of flux rope, which manifests in the form of SXR ejecta or erupting filament or CMEs, in the low corona. Moreover, for the X-class flare events studied in this paper the peak reconnection electric field is about O(10 2 V/m) or larger, enough to accelerate p articles to over 100 keV in a field-aligned distance of 10 km. Nonthermal electrons thus generated can produce hard X-rays, consistent with impulsive HXR emission observed during the flare rise phase

  8. Planned Pregnancy in a Chronic Myeloid Leukemia Patient in Molecular Remission

    Science.gov (United States)

    Pavlovsky, Carolina; Giere, Isabel; Van Thillo, Germán

    2012-01-01

    Excellent response rates and a good quality of life have been observed since the introduction of tyrosine kinase inhibitors (TKIs) in chronic myeloid leukemia (CML) treatment. Consequently, some challenges began to appear in CML women in child-bearing age wishing to become pregnant. Currently, many women around the world are in stable major/complete molecular response MMR/CMR (MMR: <0.1% BCR-ABL/ABL and CMR: undetectable BCR-ABL mRNA by RQ-PCR transcript levels on the international scale). The condition of stable MMR/CMR is linked to a long-term virtual absence of progression to the accelerated and blastic phase and to the possibility of stopping the TKI treatment with the maintenance of a condition of CMR in a proportion of cases. Imatinib teratogenic and prescribing information prohibits the use of it during pregnancy. We describe the case of a 36-year-old female patient with CML in chronic phase who stopped imatinib after 2 years in major molecular response (MMR) to plan a pregnancy. Molecular monitoring by RQ-PCR was performed quarterly. She achieved a safe pregnancy and delivery maintaining an optimal molecular response throughout the pregnancy. Isolated literature reports have been described, but no formal advice has been described at present time. PMID:22928126

  9. Self-acceleration of relativistic modulated beams

    International Nuclear Information System (INIS)

    Ajzatskij, N.I.

    1989-01-01

    Unlike the case of self-acceleration of continuous beams, the self-acceleration of relativistic modulated beams requires the energy redistribution between the particles not at the period of excited oscillations but rather between the bunches. This may occur only in the case when the electron beam creates a multifrequency equilibrium state in the passive structure. In this case, there is a possibility for some bunches to be captured in the accelerating phase of the field without any external action. The authors have analyzed this possibility both theoretically and experimentally. 12 refs., 2 figs

  10. Final Report for 'Modeling Electron Cloud Diagnostics for High-Intensity Proton Accelerators'

    International Nuclear Information System (INIS)

    Veitzer, Seth A.

    2009-01-01

    Electron clouds in accelerators such as the ILC degrade beam quality and limit operating efficiency. The need to mitigate electron clouds has a direct impact on the design and operation of these accelerators, translating into increased cost and reduced performance. Diagnostic techniques for measuring electron clouds in accelerating cavities are needed to provide an assessment of electron cloud evolution and mitigation. Accurate numerical modeling of these diagnostics is needed to validate the experimental techniques. In this Phase I, we developed detailed numerical models of microwave propagation through electron clouds in accelerating cavities with geometries relevant to existing and future high-intensity proton accelerators such as Project X and the ILC. Our numerical techniques and simulation results from the Phase I showed that there was a high probability of success in measuring both the evolution of electron clouds and the effects of non-uniform electron density distributions in Phase II.

  11. Phase I/II Study Evaluating Early Tolerance in Breast Cancer Patients Undergoing Accelerated Partial Breast Irradiation Treated With the MammoSite Balloon Breast Brachytherapy Catheter Using a 2-Day Dose Schedule

    International Nuclear Information System (INIS)

    Wallace, Michelle; Martinez, Alvaro; Mitchell, Christina; Chen, Peter Y.; Ghilezan, Mihai; Benitez, Pamela; Brown, Eric; Vicini, Frank

    2010-01-01

    Purpose: Initial Phase I/II results using balloon brachytherapy to deliver accelerated partial breast irradiation (APBI) in 2 days in patients with early-stage breast cancer are presented. Materials and Methods: Between March 2004 and August 2007, 45 patients received adjuvant radiation therapy after lumpectomy with balloon brachytherapy in a Phase I/II trial delivering 2800 cGy in four fractions of 700 cGy. Toxicities were evaluated using the National Cancer Institute Common Toxicity Criteria for Adverse Events v3.0 scale and cosmesis was documented at ≥6 months. Results: The median age was 66 years (range, 48-83) and median skin spacing was 12 mm (range, 8-24). The median follow-up was 11.4 months (5.4-48 months) with 21 patients (47%) followed ≥1 year, 11 (24%) ≥2 years, and 7 (16%) ≥3 years. At <6 months (n = 45), Grade II toxicity rates were 9% radiation dermatitis, 13% breast pain, 2% edema, and 2% hyperpigmentation. Grade III breast pain was reported in 13% (n = 6). At ≥6 months (n = 43), Grade II toxicity rates were: 2% radiation dermatitis, 2% induration, and 2% hypopigmentation. Grade III breast pain was reported in 2%. Infection was 13% (n = 6) at <6 months and 5% (n = 2) at ≥6 months. Persistent seroma ≥6 months was 30% (n = 13). Fat necrosis developed in 4 cases (2 symptomatic). Rib fractures were seen in 4% (n = 2). Cosmesis was good/excellent in 96% of cases. Conclusions: Treatment with balloon brachytherapy using a 2-day dose schedule resulted acceptable rates of Grade II/III chronic toxicity rates and similar cosmetic results observed with a standard 5-day accelerated partial breast irradiation schedule.

  12. A propensity score matching analysis of dasatinib and nilotinib as a frontline therapy for patients with chronic myeloid leukemia in chronic phase.

    Science.gov (United States)

    Takahashi, Koichi; Kantarjian, Hagop M; Yang, Yulong; Sasaki, Koji; Jain, Preetesh; DellaSala, Sara; Ravandi, Farhad; Kadia, Tapan; Pemmaraju, Naveen; Daver, Naval; Borthakur, Gautam; Garcia-Manero, Guillermo; Jabbour, Elias; Cortes, Jorge E

    2016-11-15

    Both dasatinib and nilotinib are approved frontline therapy for chronic myeloid leukemia in chronic phase (CML-CP) based on randomized trials compared with imatinib. However, no head-to-head comparison of dasatinib and nilotinib has been conducted in patients with newly diagnosed CML-CP. The authors conducted a propensity score (PS) matched comparison of patients with CML-CP who received frontline therapy with either dasatinib (N = 102) or nilotinib (N = 104) under the respective phase 2 trials conducted in parallel. PS matching resulted in 87 patients from each trial being matched for pretreatment characteristics. The 3-month BCR-ABL1/ABL1 ratio treatment cohorts. The 3-year probability of event-free survival was 89% among the patients who received dasatinib and 87% among those who received nilotinib (P = .99), and the corresponding 3-year overall survival probabilities were 99% and 93%, respectively (P = .95). No statistical difference was observed between the dasatinib and nilotinib groups in any of the other survival endpoints. The treatment discontinuation rate also was similar between the 2 cohorts (dasatinib group, 18%; nilotinib group, 19%; P = .82). In a PS-matched cohort of patients with newly diagnosed CML-CP, dasatinib and nilotinib offer similar response and survival outcomes. Both drugs can be considered reasonable standard-of-care options as first-line therapy for patients with CML-CP. Cancer 2016;122:3336-3343. © 2016 American Cancer Society. © 2016 American Cancer Society.

  13. Low-β acceleration with a MEQALAC

    International Nuclear Information System (INIS)

    van Amersfoort, P.W.; Siebenlist, F.; Thomae, R.W.; Woljke, R.; Schonewille, F.G.; Ivanov, S.T.; Klein, H.; Schempp, A.; Weis, T.

    1986-01-01

    In a Multiple Electrostatic Quadrupole Array Linear Accelerator (MEQALAC) a number of parallel beams is accelerated simultaneously. This devise is useful for exit energies up to 1 MeV per nucleon. Radial stability is provided by electrostatic quadrupole lenses placed between successive acceleration gaps. The proof-of-principle MEQALAC presently available at FOM features four He + ion beams which are accelerated to an energy of 120 keV. The resonator cavity has a modified Interdigital-H-structure and contains 20 acceleration gaps. Its resonance frequency is 40 MHz. Transmission measurements on injected beams with currents ranging from 1 to 15 mA are presented. The transverse phase advance per cell of the quadrupole channels is varied between 43 0 and 114 0 . A maximum current of 2.2 mA per channel has been accelerated. A design for a MEQALAC which will be used for acceleration of N + ions to 1 MeV is presented. This accelerator will be operated at various frequencies to allow for a variation of the exit energy

  14. High energy particle accelerators as radiation Sources

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, M E [National Center for Nuclear Safety and Radiation Vontrol, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    Small accelerators in the energy range of few million electron volts are usually used as radiation sources for various applications, like radiotherapy, food irradiation, radiation sterilization and in other industrial applications. High energy accelerators with energies reaching billions of electron volts also find wide field of applications as radiation sources. Synchrotrons with high energy range have unique features as radiation sources. This review presents a synopsis of cyclic accelerators with description of phase stability principle of high energy accelerators with emphasis on synchrotrons. Properties of synchrotron radiation are given together with their applications in basic and applied research. 13 figs.,1 tab.

  15. The association between microhaemorrhages and post - traumatic functional outcome in the chronic phase after mild traumatic brain injury

    Energy Technology Data Exchange (ETDEWEB)

    Haan, S. de; Groot, J.C. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Jacobs, B.; Naalt, J. van der [University Medical Center Groningen, Department of Neurology, University of Groningen, Groningen (Netherlands)

    2017-10-15

    In the chronic phase after mild traumatic brain injury (mTBI), microhaemorrhages are frequently detected on magnetic resonance imaging (MRI). It is however unclear whether microhaemorrhages are associated with functional outcome and which MRI sequence is most appropriate to address this association. We aimed to determine the association between microhaemorrhages and functional outcome in the chronic posttraumatic phase after injury with the most suitable MRI sequence to address this association. One hundred twenty-seven patients classified with mTBI admitted to the outpatient clinic from 2008 to 2015 for persisting posttraumatic complaints were stratified according to the presence of MRI abnormalities (n = 63 (MRI+ group) and n = 64 without abnormalities (MRI- group)). For the detection of microhaemorrhages, susceptibility-weighted imaging (SWI) and T2* gradient recalled echo (T2*GRE) were used. The relation between the functional outcome (dichotomized Glasgow Outcome Scale Extended scores) and the number and localization of microhaemorrhages was analysed using binary logistic regression. SWI detected twice as many microhaemorrhages compared to T2*GRE: 341 vs. 179. Lesions were predominantly present in the frontal and temporal lobes. Unfavourable outcome was present in 67% of the MRI+ group with a significant association of total number of microhaemorrhages in the temporal cortical area on SWI (OR 0.43 (0.21-0.90) p = 0.02), with an explained variance of 44%. The number of microhaemorrhages was not correlated with the number of posttraumatic complaints. An unfavourable outcome in the chronic posttraumatic phase is associated with the presence and number of microhaemorrhages in the temporal cortical area. SWI is preferably used to detect these microhaemorrhages. (orig.)

  16. The association between microhaemorrhages and post - traumatic functional outcome in the chronic phase after mild traumatic brain injury

    International Nuclear Information System (INIS)

    Haan, S. de; Groot, J.C. de; Jacobs, B.; Naalt, J. van der

    2017-01-01

    In the chronic phase after mild traumatic brain injury (mTBI), microhaemorrhages are frequently detected on magnetic resonance imaging (MRI). It is however unclear whether microhaemorrhages are associated with functional outcome and which MRI sequence is most appropriate to address this association. We aimed to determine the association between microhaemorrhages and functional outcome in the chronic posttraumatic phase after injury with the most suitable MRI sequence to address this association. One hundred twenty-seven patients classified with mTBI admitted to the outpatient clinic from 2008 to 2015 for persisting posttraumatic complaints were stratified according to the presence of MRI abnormalities (n = 63 (MRI+ group) and n = 64 without abnormalities (MRI- group)). For the detection of microhaemorrhages, susceptibility-weighted imaging (SWI) and T2* gradient recalled echo (T2*GRE) were used. The relation between the functional outcome (dichotomized Glasgow Outcome Scale Extended scores) and the number and localization of microhaemorrhages was analysed using binary logistic regression. SWI detected twice as many microhaemorrhages compared to T2*GRE: 341 vs. 179. Lesions were predominantly present in the frontal and temporal lobes. Unfavourable outcome was present in 67% of the MRI+ group with a significant association of total number of microhaemorrhages in the temporal cortical area on SWI (OR 0.43 (0.21-0.90) p = 0.02), with an explained variance of 44%. The number of microhaemorrhages was not correlated with the number of posttraumatic complaints. An unfavourable outcome in the chronic posttraumatic phase is associated with the presence and number of microhaemorrhages in the temporal cortical area. SWI is preferably used to detect these microhaemorrhages. (orig.)

  17. Acceleration Modes and Transitions in Pulsed Plasma Accelerators

    Science.gov (United States)

    Polzin, Kurt A.; Greve, Christine M.

    2018-01-01

    acceleration of the plasma depending upon the behavior of the plasma discharge during initial transient phase and the relative lengths of the detonation and deflagration modes of operation.

  18. Accelerator programme at CAT

    International Nuclear Information System (INIS)

    Ramamurthi, S.S.

    1991-01-01

    The Accelerator Programme at the Centre for Advanced Technology (CAT), Indore, has very broad based concept under which all types of accelerators are to be taken up for design and fabrication. This centre will be housing a wide variety of accelerators to serve as a common facility for the universities, national laboratories in addition to laboratories under the Department of Atomic Energy. In the first phase of the programme, a series of electron accelerators are designed and fabricated. They are synchrotron radiation sources of 450 MeV (INDUS-I) and of 2 GeV (INDUS-II), microtron upto energy of 20 MeV, linear accelerator upto 20 MeV, and DC Accelerator for industrial irradiation upto 750 KeV and 20 KW. A proton accelerator of 300 MeV with 20 MeV linac injector is also designed. CAT is also developing a strong base for support technologies like ultra high vacuum, radio frequency and microwaves, DC pulsed and superconducting magnets, power supplies and controls etc. These technologies are very useful for other industrial applications also. To develop user groups to utilise INDUS-II synchrotron radiation source, a batch production of rotating Anode X-ray generators with power supplies has been initiated. So also, the sputter ion pumps, electron guns, turbo molecular pumps are brought into batch production. (author)

  19. Evaluation of the Safety of Imatinib Mesylate in 200 Iraqi Patients with Chronic Myeloid Leukemia in the Chronic Phase: Single-Center Study

    Directory of Open Access Journals (Sweden)

    Bassam Francis Matti

    2013-12-01

    Full Text Available OBJECTIVE: Imatinib mesylate, a tyrosine kinase inhibitor, is presently the drug of choice for chronic myeloid leukemia (CML. During therapy, a few patients may develop hematological and non-hematological adverse effects. METHODS: The aim of this study was to evaluate the safety of imatinib therapy in patients with CML. Between December 2007 and October 2009 two hundred patients with CML in chronic phase were included in the study. Written informed consent was obtained from all patients prior to the start of the study. Imatinib was started at 400 mg orally daily. Patients were monitored carefully for any adverse effects. Complete blood count, liver, and renal function tests were done once in 2 weeks during the first month and on a monthly basis during follow-up. Toxicities that encountered were graded as per the National Cancer Institute common toxicity criteria version 2. Both hematologic and non-hematologic toxicities were managed with short interruptions of treatment and supportive measures, but the daily dose of imatinib was not reduced below 300 mg/day. RESULTS: Two hundred CML patients in chronic phase were included in this study; the male: female ratio was 0.7: 1 with mean age 39.06±13.21 years (ranged from 15-81 years. The study showed that the commonest hematological side effects were grade 2 anemia (12.5% followed by leukopenia (8% and thrombocytopenia (4%, while the most common non-hematological adverse effects were superficial edema and weight gain (51.5%, followed by musculoskeletal pain (35.5%, then gastro-intestinal symptoms (vomiting, diarrhea (19%. Fluid retention was the commonest side effect, which responded to low-dose diuretics. The drug was safe and well tolerated. There were no deaths due to toxicity. CONCLUSION: Imatinib mesylate a well-tolerated drug, and all undesirable effects could be ameliorated easily. The most common hematological and non-hematological side effects were anemia and fluid retention, respectively.

  20. Final 5-Year Study Results of DASISION: The Dasatinib Versus Imatinib Study in Treatment-Naïve Chronic Myeloid Leukemia Patients Trial.

    Science.gov (United States)

    Cortes, Jorge E; Saglio, Giuseppe; Kantarjian, Hagop M; Baccarani, Michele; Mayer, Jiří; Boqué, Concepción; Shah, Neil P; Chuah, Charles; Casanova, Luis; Bradley-Garelik, Brigid; Manos, George; Hochhaus, Andreas

    2016-07-10

    We report the 5-year analysis from the phase III Dasatinib Versus Imatinib Study in Treatment-Naïve Chronic Myeloid Leukemia Patients (DASISION) trial, evaluating long-term efficacy and safety outcomes of patients with chronic myeloid leukemia (CML) in chronic phase (CP) treated with dasatinib or imatinib. Patients with newly diagnosed CML-CP were randomly assigned to receive dasatinib 100 mg once daily (n = 259) or imatinib 400 mg once daily (n = 260). At the time of study closure, 61% and 63% of dasatinib- and imatinib-treated patients remained on initial therapy, respectively. Cumulative rates of major molecular response and molecular responses with a 4.0- or 4.5-log reduction in BCR-ABL1 transcripts from baseline by 5 years remained statistically significantly higher for dasatinib compared with imatinib. Rates for progression-free and overall survival at 5 years remained high and similar across treatment arms. In patients who achieved BCR-ABL1 ≤ 10% at 3 months (dasatinib, 84%; imatinib, 64%), improvements in progression-free and overall survival and lower rates of transformation to accelerated/blast phase were reported compared with patients with BCR-ABL1 greater than 10% at 3 months. Transformation to accelerated/blast phase occurred in 5% and 7% of patients in the dasatinib and imatinib arms, respectively. Fifteen dasatinib-treated and 19 imatinib-treated patients had BCR-ABL1 mutations identified at discontinuation. There were no new or unexpected adverse events identified in either treatment arm, and pleural effusion was the only drug-related, nonhematologic adverse event reported more frequently with dasatinib (28% v 0.8% with imatinib). First occurrences of pleural effusion were reported with dasatinib, with the highest incidence in year 1. Arterial ischemic events were uncommon in both treatment arms. These final results from the DASISION trial continue to support dasatinib 100 mg once daily as a safe and effective first-line therapy for the long

  1. Improved voltage performance of the Oak Ridge 25URC tandem accelerator

    International Nuclear Information System (INIS)

    Meigs, M.J.; Jones, C.M.; Haynes, D.L.; Juras, R.C.; Ziegler, N.F.; Raatz, J.E.; Rathmell, R.D.

    1988-01-01

    While voltage performance of the accelerator has been adequate for the experimental program to date, it seemed clear that improvement in voltage performance could be of direct benefit to the experimental program in the future. Therefore, we began, in June 1986, a program of modifications and tests which was designed to improve voltage performance of the accelerator. In this paper, we discuss the final phase of this program and initial tests of the accelerator following completion of this final phase. 11 refs., 4 figs

  2. Research on accelerator-driven transmutation and studies of experimental facilities

    Energy Technology Data Exchange (ETDEWEB)

    Takizuka, Takakazu [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-11-01

    JAERI is carrying out R and Ds on accelerator-driven transmutation systems under the national OMEGA Program that aims at development of the technology to improve efficiency and safety in the final disposal of radioactive waste. Research facilities for accelerator-driven transmutation experiments are proposed to construct within the framework of the planned JAERI Neutron Science Project. This paper describes the features of the proposed accelerator-driven transmutation systems and their technical issues to be solved. A research facility plan under examination is presented. The plan is divided in two phases. In the second phase, technical feasibility of accelerator-driven systems will be demonstrated with a 30-60 MW experimental integrated system and with a 7 MW high-power target facility. (author)

  3. Phase II study of palliative low-dose local radiotherapy in disseminated indolent non-Hodgkin's lymphoma and chronic lymphocytic leukemia

    DEFF Research Database (Denmark)

    Jóhannsson, Jakob; Specht, Lena; Mejer, Johannes

    2002-01-01

    Indolent non-Hodgkin's lymphoma (INHL) and chronic lymphocytic leukemia (CLL) are highly sensitive to radiotherapy (RT). Previous retrospective studies have shown high response rates after local palliative RT of 4 Gy in 2 fractions, which prompted this prospective Phase II trial of the palliative...

  4. Geometric analysis of phase bunching in the central region of cyclotron

    International Nuclear Information System (INIS)

    Miyawaki, Nobumasa; Fukuda, Mitsuhiro; Kurashima, Satoshi; Kashiwagi, Hirotsugu; Okumura, Susumu; Arakawa, Kazuo; Kamiya, Tomihiro

    2013-01-01

    An optimum condition for realizing phase bunching in the central region of a cyclotron was quantitatively clarified by a simplified geometric trajectory analysis of charged particles from the first to the second acceleration gap. The phase bunching performance was evaluated for a general case of a cyclotron. The phase difference of incident particles at the second acceleration gap depends on the combination of four parameters: the acceleration harmonic number h, the span angle θ D of the dee electrode, the span angle θ F from the first to the second acceleration gap, the ratio R V of the peak acceleration voltage between the cyclotron and ion source. Optimum values of θ F for phase bunching were limited by the relationship between h and θ D , which is 90°/h+θ D /2≤θ F ≤180°/h+θ D /2, and sin θ F >0. The phase difference with respect to the reference particle at the second acceleration gap is minimized for voltage-ratios between two and four for an initial phase difference within 40 RF degrees. Although the slope of the first acceleration gap contributes to the RF phase at which the particles reach the second acceleration gap, phase bunching was not affected. An orbit simulation of the AVF cyclotron at the Japan Atomic Energy Agency verifies the evaluation based on geometric analysis

  5. Parallel imaging with phase scrambling.

    Science.gov (United States)

    Zaitsev, Maxim; Schultz, Gerrit; Hennig, Juergen; Gruetter, Rolf; Gallichan, Daniel

    2015-04-01

    Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. Quadratic phase is imparted to the image to spread the signals in k-space (aka phase scrambling). By rewriting the Fourier transform as a convolution operation, a window can be introduced to the convolved chirp function, allowing a low-resolution image to be reconstructed from phase-scrambled data without prominent aliasing. This image (for each RF channel) can be used to derive coil sensitivities to drive existing parallel imaging techniques. As a proof of concept, the quadratic phase was applied by introducing an offset to the x(2) - y(2) shim and the data were reconstructed using adapted versions of the image space-based sensitivity encoding and GeneRalized Autocalibrating Partially Parallel Acquisitions algorithms. The method is demonstrated in a phantom (1 × 2, 1 × 3, and 2 × 2 acceleration) and in vivo (2 × 2 acceleration) using a 3D gradient echo acquisition. Phase scrambling can be used to perform parallel imaging acceleration without acquisition of separate coil calibration data, demonstrated here for a 3D-Cartesian trajectory. Further research is required to prove the applicability to other 2D and 3D sampling schemes. © 2014 Wiley Periodicals, Inc.

  6. Comparison of high group velocity accelerating structures

    International Nuclear Information System (INIS)

    Farkas, Z.D.; Wilson, P.B.

    1987-02-01

    It is well known that waveguides with no perturbations have phase velocities greater than the velocity of light c. If the waveguide dimensions are chosen so that the phase velocity is only moderately greater than c, only small perturbations are required to reduce the phase velocity to be synchronous with a high energy particle bunch. Such a lightly loaded accelerator structure will have smaller longitudinal and transverse wake potentials and hence will lead to lower emittance growth in an accelerated beam. Since these structures are lightly loaded, their group velocities are only slightly less than c and not in the order of 0.01c, as is the case for the standard disk-loaded structures. To ascertain that the peak and average power requirements for these structures are not prohibitive, we examine the elastance and the Q for several traveling wave structures: phase slip structures, bellows-like structures, and lightly loaded disk-loaded structures

  7. Laser beam accelerator

    International Nuclear Information System (INIS)

    Tajima, T.; Dawson, J.M.

    1981-01-01

    Parallel intense photon (laser, microwave, etc.) beams /omega/sub //0, k/sub 0/ and /omega/sub //1, k/sub 1/ shone on a plasma with frequency separation equal to the plasma frequency /omega/sub //p is capable of accelerating plasma electrons to high energies in large flux. The photon beat excites through the forward Raman scattering large amplitude plasmons whose phase velocity is equal to (/omega/ /sub 0/-/omega/sub //1)/(k/sub 0/-k/sub 1/), close to c in an underdense plasma. The multiple forward Raman instability produces smaller and smaller frequency and group velocity of photons; thus the photons slow down in the plasma by emitting accelerated electrons (inverse Cherenkov process). 6 refs

  8. Plasma wave accelerator. II

    International Nuclear Information System (INIS)

    Mori, W.; Joshi, C.; Dawson, J.M.

    1982-01-01

    It was shown that the insertion of a cross magnetic field prevents the particles from getting out of phase with the electric field of the plasma wave in the beat wave accelerator scheme. Thus, using a CO 2 laser, n/sub c//n/sub e/ = (ω 0 /ω/sub p/) 2 approx. 35, and a 300 kG magnetic field, electrons can be (in principle) accelerated to 100 GeV in 2 meters. For comparison without the magnetic field, the same energies may be obtained in a n/sub c//n/sub e/ approx. 10 5 plasma over a distance of 100 meters

  9. Accelerated cognitive decline in a rodent model for temporal lobe epilepsy.

    Science.gov (United States)

    Schipper, Sandra; Aalbers, Marlien W; Rijkers, Kim; Lagiere, Melanie; Bogaarts, Jan G; Blokland, Arjan; Klinkenberg, Sylvia; Hoogland, Govert; Vles, Johan S H

    2016-12-01

    Cognitive impairment is frequently observed in patients with temporal lobe epilepsy. It is hypothesized that cumulative seizure exposure causes accelerated cognitive decline in patients with epilepsy. We investigated the influence of seizure frequency on cognitive decline in a rodent model for temporal lobe epilepsy. Neurobehavioral assessment was performed before and after surgery, after the induction of self-sustaining limbic status epilepticus (SSLSE), and in the chronic phase in which rats experienced recurrent seizures. Furthermore, we assessed potential confounders of memory performance. Rats showed a deficit in spatial working memory after the induction of the SSLSE, which endured in the chronic phase. A progressive decline in recognition memory developed in SSLSE rats. Confounding factors were absent. Seizure frequency and also the severity of the status epilepticus were not correlated with the severity of cognitive deficits. The effect of the seizure frequency on cognitive comorbidity in epilepsy has long been debated, possibly because of confounders such as antiepileptic medication and the heterogeneity of epileptic etiologies. In an animal model of temporal lobe epilepsy, we showed that a decrease in spatial working memory does not relate to the seizure frequency. This suggests for other mechanisms are responsible for memory decline and potentially a common pathophysiology of cognitive deterioration and the occurrence and development of epileptic seizures. Identifying this common denominator will allow development of more targeted interventions treating cognitive decline in patients with epilepsy. The treatment of interictal symptoms will increase the quality of life of many patients with epilepsy. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Control of electron injection and acceleration in laser-wakefield accelerators

    International Nuclear Information System (INIS)

    Guillaume, E.

    2015-01-01

    Laser-plasma accelerators provide a promising compact alternative to conventional accelerators. Plasma waves with extremely strong electric fields are generated when a high intensity laser is focused into an underdense gas target. Electrons that are trapped in these laser-driven plasma waves can be accelerated up to energies of a few GeVs. Despite their great potential, laser-wakefield accelerators face some issues, regarding notably the stability and reproducibility of the beam when electrons are injected in the accelerating structure. In this manuscript, different techniques of electron injection are presented and compared, notably injection in a sharp density gradient and ionization injection. It is shown that combining these two methods allows for the generation of stable and tunable electron beams. We have also studied a way to manipulate the electron bunch in the phase-space in order to accelerate the bunch beyond the dephasing limit. Such a technique was used with quasi-monoenergetic electron beams to enhance their energy. Moreover, the origin of the evolution of the angular momentum of electrons observed experimentally was investigated. Finally, we demonstrated experimentally a new method - the laser-plasma lens - to strongly reduce the divergence of the electron beam. This laser-plasma lens consists of a second gas jet placed at the exit of the accelerator. The laser pulse drives a wakefield in this second jet whose focusing forces take advantage to reduce the divergence of the trailing electron bunch. A simple analytical model describing the principle is presented, underlining the major importance of the second jet length, density and distance from the first jet. Experimental demonstration of the laser-plasma lens shows a divergence reduction by a factor of 2.6 for electrons up to 300 MeV, in accordance with the model predictions

  11. Measurements of beat wave accelerated electrons in a toroidal plasma

    International Nuclear Information System (INIS)

    Rogers, J.H.

    1992-06-01

    Electrons are accelerated by large amplitude electron plasma waves driven by counter-propagating microwaves with a difference frequency approximately equal to the electron plasma frequency. Energetic electrons are observed only when the phase velocity of the wave is in the range 3v e ph e (v ph was varied 2v e ph e ), where v e is the electron thermal velocity, (kT e /m e ) 1/2 . As the phase velocity increases, fewer electrons are accelerated to higher velocities. The measured current contained in these accelerated electrons has the power dependence predicted by theory, but the magnitude is lower than predicted

  12. Theoretical and numerical study of the acceleration of particles in the separated sector cyclotrons (SSC's) at the large national heavy ion accelerator (GANIL)

    International Nuclear Information System (INIS)

    Chabert, A.; Gendreau, G.; Sauret, J.; Cardin, L.

    The ideal machine is first considered, and the following topics are covered: (1) characteristics of accelerator cavities; (2) flat-topping; (3) the traverse of one acceleration interval; (4) the energy gain during the crossing of a cavity; and (5) beam injection conditions. A study is given of the coupling, including space charge forces, phase compression, and the effect of the angular opening of the accelerator cavities. The tolerances on the beam injection parameters and on the accelerator system are discussed

  13. Mathematical Modeling Of The Acceleration Process In Race-track Microtron

    CERN Document Server

    Gromov, A M; Vasilev, A A

    2004-01-01

    The precise calculations of beam dynamics are needed to make choice of optimal design parameters of race-track microtron. As a result, the necessary physical require-ments to the accelerator systems become found. For cal-culation of the magnetic field, POISSON LANL code is used. Acceleration of the beam is investigated with the help of the program of MathCad. Nonlinear distribution of the field in magnets of micro-tron with adjustable reverse field was simulated. The equation of motion of a beam in bending magnets of re-circulation system are found and solved by a numerical method. Trajectories of the beam for all orbits in a micro-tron are received. The recursive equation for calculation of the largest area of injected beam phase and power spreads providing steady acceleration process is written. The acceleration of the beam with maximal phase-energy area through all orbits of microtron was simulated. The velocity of accelerated particles on first orbits dif-fers from velocity of light. The minimal energy ...

  14. CO2 laser technology for advanced particle accelerators

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.

    1996-06-01

    Short-pulse, high-power CO 2 lasers open new prospects for development of ultra-high gradient laser-driven electron accelerators. The advantages of λ=10 μm CO 2 laser radiation over the more widely exploited solid state lasers with λ∼1 μm are based on a λ 2 -proportional ponderomotive potential, λ-proportional phase slippage, and λ-proportional scaling of the laser accelerator structures. We show how a picosecond terawatt CO 2 laser that is under construction at the Brookhaven Accelerator Test Facility may benefit the ATF's experimental program of testing far-field, near-field, and plasma accelerator schemes

  15. Prevalence of chronic cough, chronic phlegm & associated factors in Mysore, Karnataka, India.

    Science.gov (United States)

    Mahesh, P A; Jayaraj, B S; Prabhakar, A K; Chaya, S K; Vijayasimha, R

    2011-07-01

    Chronic cough and chronic phlegm are important indicators of respiratory morbidity, accelerated lung function decline, increased hospitalization and mortality. This study was planned to estimate the prevalence of chronic cough and phlegm in the absence of dyspneoa and wheezing and to study its associated factors in a representative population of Mysore district. A cross-sectional survey was planned in a representative population of Mysore taluk. Eight villages were randomly selected based on the list of villages from census 2001. Trained field workers using the Burden of Obstructive Diseases questionnaire carried out a house-to-house survey. A total of 4333 adult subjects were enrolled in the study with 2333 males and 2000 females. The prevalence of chronic cough in the community was 2.5 per cent and that of chronic phlegm was 1.2 per cent. A significant association was observed between chronic cough and age, gender, occupation and smoking and chronic phlegm with age, gender, occupation, indoor animals and smoking. A multivariate analysis confirmed independent association of age, occupation and smoking for chronic cough and age and smoking for chronic phlegm. On sub-group analysis of males, heavy smokers had higher prevalence of chronic cough and chronic phlegm as compared to light smokers and non smokers. The prevalence of chronic cough was 2.5 per cent and chronic phlegm was 1.2 per cent in the general population in Mysore which is lower than that observed in other studies. Heavy smoking was an important preventable risk factor identified in this study and efforts towards smoking cessation are crucial to achieve good respiratory health in the community.

  16. Prospects for Accelerator Technology

    Science.gov (United States)

    Todd, Alan

    2011-02-01

    Accelerator technology today is a greater than US$5 billion per annum business. Development of higher-performance technology with improved reliability that delivers reduced system size and life cycle cost is expected to significantly increase the total accelerator technology market and open up new application sales. Potential future directions are identified and pitfalls in new market penetration are considered. Both of the present big market segments, medical radiation therapy units and semiconductor ion implanters, are approaching the "maturity" phase of their product cycles, where incremental development rather than paradigm shifts is the norm, but they should continue to dominate commercial sales for some time. It is anticipated that large discovery-science accelerators will continue to provide a specialty market beset by the unpredictable cycles resulting from the scale of the projects themselves, coupled with external political and economic drivers. Although fraught with differing market entry difficulties, the security and environmental markets, together with new, as yet unrealized, industrial material processing applications, are expected to provide the bulk of future commercial accelerator technology growth.

  17. Cosmic acceleration driven by mirage inhomogeneities

    Energy Technology Data Exchange (ETDEWEB)

    Galfard, Christophe [DAMTP, Centre for Mathematical Sciences, University of Cambridge, Wilberforce road, Cambridge CB3 0WA (United Kingdom); Germani, Cristiano [DAMTP, Centre for Mathematical Sciences, University of Cambridge, Wilberforce road, Cambridge CB3 0WA (United Kingdom); Kehagias, Alex [Physics Division, National Technical University of Athens, 15780 Zografou Campus, Athens (Greece)

    2006-03-21

    A cosmological model based on an inhomogeneous D3-brane moving in an AdS{sub 5} x S{sub 5} bulk is introduced. Although there are no special points in the bulk, the brane universe has a centre and is isotropic around it. The model has an accelerating expansion and its effective cosmological constant is inversely proportional to the distance from the centre, giving a possible geometrical origin for the smallness of a present-day cosmological constant. Besides, if our model is considered as an alternative of early-time acceleration, it is shown that the early stage accelerating phase ends in a dust-dominated FRW homogeneous universe. Mirage-driven acceleration thus provides a dark matter component for the brane universe final state. We finally show that the model fulfils the current constraints on inhomogeneities.

  18. Pulsed power accelerators for particle beam fusion

    International Nuclear Information System (INIS)

    Martin, T.H.; Barr, G.W.; VanDevender, J.P.; White, R.A.; Johnson, D.L.

    1980-01-01

    Sandia National Laboratories is completing the construction phase of the Particle Beam Fusion Accelerator-I (PBFA-I). Testing of the 36 module, 30 TW, 1 MJ output accelerator is in the initial stages. The 4 MJ, PBFA Marx generator has provided 3.6 MA into water-copper sulfate load resistors with a spread from first to last Marx firing between 15 to 25 ns and an output power of 5.7 TW. This accelerator is a modular, lower voltage, pulsed power device that is capable of scaling to power levels exceeding 100 TW. The elements of the PBFA technology and their integration into an accelerator system for particle beam fusion will be discussed

  19. BCR-ABL1 mutation development during first-line treatment with dasatinib or imatinib for chronic myeloid leukemia in chronic phase.

    Science.gov (United States)

    Hughes, T P; Saglio, G; Quintás-Cardama, A; Mauro, M J; Kim, D-W; Lipton, J H; Bradley-Garelik, M B; Ukropec, J; Hochhaus, A

    2015-09-01

    BCR-ABL1 mutations are a common, well-characterized mechanism of resistance to imatinib as first-line treatment of chronic myeloid leukemia in chronic phase (CML-CP). Less is known about mutation development during first-line treatment with dasatinib and nilotinib, despite increased use because of higher response rates compared with imatinib. Retrospective analyses were conducted to characterize mutation development in patients with newly diagnosed CML-CP treated with dasatinib (n=259) or imatinib (n=260) in DASISION (Dasatinib versus Imatinib Study in Treatment-Naive CML-CP), with 3-year minimum follow-up. Mutation screening, including patients who discontinued treatment and patients who had a clinically relevant on-treatment event (no confirmed complete cytogenetic response (cCCyR) and no major molecular response (MMR) within 12 months; fivefold increase in BCR-ABL1 with loss of MMR; loss of CCyR), yielded a small number of patients with mutations (dasatinib, n=17; imatinib, n=18). Dasatinib patients had a narrower spectrum of mutations (4 vs 12 sites for dasatinib vs imatinib), fewer phosphate-binding loop mutations (1 vs 9 mutations), fewer multiple mutations (1 vs 6 patients) and greater occurrence of T315I (11 vs 0 patients). This trial was registered at www.clinicaltrials.gov as NCT00481247.

  20. Evaluation of the Acceleration and Deceleration Phase-Rectified Slope to Detect and Improve IUGR Clinical Management

    Directory of Open Access Journals (Sweden)

    Salvatore Tagliaferri

    2015-01-01

    Full Text Available Objective. This study used a new method called Acceleration (or Deceleration Phase-Rectified Slope, APRS (or DPRS to analyze computerized Cardiotocographic (cCTG traces in intrauterine growth restriction (IUGR, in order to calculate acceleration- and deceleration-related fluctuations of the fetal heart rate, and to enhance the prediction of neonatal outcome. Method. Cardiotocograms from a population of 59 healthy and 61 IUGR fetuses from the 30th gestation week matched for gestational age were included. APRS and DPRS analysis was compared to the standard linear and nonlinear cCTG parameters. Statistical analysis was performed through the t-test, ANOVA test, Pearson correlation test and receiver operator characteristic (ROC curves (p<0,05. Results. APRS and DPRS showed high performance to discriminate between Healthy and IUGR fetuses, according to gestational week. A linear correlation with the fetal pH at birth was found in IUGR. The area under the ROC curve was 0.865 for APRS and 0.900 for DPRS before the 34th gestation week. Conclusions. APRS and DPRS could be useful in the identification and management of IUGR fetuses and in the prediction of the neonatal outcome, especially before the 34th week of gestation.

  1. High-gradient electron accelerator powered by a relativisitic klystron

    International Nuclear Information System (INIS)

    Allen, M.A.; Boyd, J.K.; Callin, R.S.; Deruyter, H.; Eppley, K.R.; Fant, K.S.; Fowkes, W.R.; Haimson, J.; Hoag, H.A.; Hopkins, D.B.; Houck, T.; Koontz, R.F.; Lavine, T.L.; Loew, G.A.; Mecklenburg, B.; Miller, R.H.; Ruth, R.D.; Ryne, R.D.; Sessler, A.M.; Vlieks, A.E.; Wang, J.W.; Westenskow, G.A.; Yu, S.S.

    1989-01-01

    We have used relativistic klystron technology to extract 290 MW of peak power at 11.4 GHz from an induction linac beam, and to power a short 11.4-GHz high-gradient accelerator. We have measured rf phase stability, field emission, and the momentum spectrum of an accelerated electron beam. An average accelerating gradient of 84 MV/m has been achieved with 80 MW of relativistic klystron power

  2. Silicon Carbide (SiC) Device and Module Reliability, Performance of a Loop Heat Pipe Subjected to a Phase-Coupled Heat Input to an Acceleration Field

    Science.gov (United States)

    2016-05-01

    AFRL-RQ-WP-TR-2016-0108 SILICON CARBIDE (SiC) DEVICE AND MODULE RELIABILITY Performance of a Loop Heat Pipe Subjected to a Phase-Coupled...CARBIDE (SiC) DEVICE AND MODULE RELIABILITY Performance of a Loop Heat Pipe Subjected to a Phase-Coupled Heat Input to an Acceleration Field 5a...Shukla, K., “Thermo-fluid dynamics of Loop Heat Pipe Operation,” International Communications in Heat and Mass Transfer , Vol. 35, No. 8, 2008, pp

  3. Unlimited ion acceleration by radiation pressure.

    Science.gov (United States)

    Bulanov, S V; Echkina, E Yu; Esirkepov, T Zh; Inovenkov, I N; Kando, M; Pegoraro, F; Korn, G

    2010-04-02

    The energy of ions accelerated by an intense electromagnetic wave in the radiation pressure dominated regime can be greatly enhanced due to a transverse expansion of a thin target. The expansion decreases the number of accelerated ions in the irradiated region resulting in an increase in the ion energy and in the ion longitudinal velocity. In the relativistic limit, the ions become phase locked with respect to the electromagnetic wave resulting in unlimited ion energy gain.

  4. Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging

    International Nuclear Information System (INIS)

    Van Gorp, Jetse S; Bakker, Chris J G; Bouwman, Job G; Zijlstra, Frank; Seevinck, Peter R; Smink, Jouke

    2015-01-01

    In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicated undersampling patterns were implemented on a clinical scanner. Additionally, a 3D multi-spectral spin-echo (ms3D-SE) sequence was implemented for reference purposes. First, we demonstrated the influence of susceptibility induced off-resonance effects on the spatial encoding of broadband 3D-SE, ms3D-SE, 3D-PE-SE and 3D-PE-TSE using a grid phantom containing a titanium implant (Δχ = 182 ppm) with x-ray CT as a gold standard. These experiments showed that the spatial encoding of 3D-PE-(T)SE was unaffected by susceptibility induced off-resonance effects, which caused geometrical distortions and/or signal hyper-intensities in broadband 3D-SE and, to a lesser extent, in ms3D-SE frequency encoded methods. Additionally, an SNR analysis was performed and the temporally resolved signal of 3D-PE-(T)SE sequences was exploited to retrospectively decrease the acquisition bandwidth and obtain field offset maps. The feasibility of CS acceleration was studied retrospectively and prospectively for the 3D-PE-SE sequence using an existing CS algorithm adapted for the reconstruction of 3D data with undersampling in all three phase encoded dimensions. CS was combined with turbo-acceleration by variable density undersampling and spherical stepwise T 2 weighting by randomly sorting consecutive echoes in predefined spherical k-space layers. The CS-TSE combination resulted in an overall acceleration factor of 60, decreasing the original 3D-PE-SE scan time from 7 h to 7 min. Finally, CS accelerated 3D-PE-TSE in vivo images of a titanium screw were obtained within 10 min using a micro-coil demonstrating the feasibility of geometrically undistorted MRI near severe

  5. Two-beam accelerator

    International Nuclear Information System (INIS)

    Sessler, A.M.; Hopkins, D.B.

    1986-06-01

    The Two-Beam Accelerator (TBA) consists of a long high-gradient accelerator structure (HGS) adjacent to an equal-length Free Electron Laser (FEL). In the FEL, a beam propagates through a long series of undulators. At regular intervals, waveguides couple microwave power out of the FEL into the HGS. To replenish energy given up by the FEL beam to the microwave field, induction accelerator units are placed periodically along the length of the FEL. In this manner it is expected to achieve gradients of more than 250 MV/m and thus have a serious option for a 1 TeV x 1 TeV linear collider. The state of present theoretical understanding of the TBA is presented with particular emphasis upon operation of the ''steady-state'' FEL, phase and amplitude control of the rf wave, and suppression of sideband instabilities. Experimental work has focused upon the development of a suitable HGS and the testing of this structure using the Electron Laser Facility (ELF). Description is given of a first test at ELF with a seven-cell 2π/3 mode structure which without preconditioning and with a not-very-good vacuum nevertheless at 35 GHz yielded an average accelerating gradient of 180 MV/m

  6. Staged electron laser accelerator (STELLA) experiment at brookhaven ATF

    Energy Technology Data Exchange (ETDEWEB)

    Pogorelsky, I V; Steenbergen, A van; Gallardo, J C [Brookhaven National Lab., Upton, NY (United States); and others

    1998-03-01

    The STELLA experiment is being prepared at the BNL Accelerator Test Facility (STF). The goal of the experiment is to demonstrate quasi-monochromatic inverse Cherenkov acceleration (ICA) of electrons bunched to the laser wavelength period. Microbunches on the order of 2 {mu}m in length separated by 10.6 {mu}m will be produced using an inverse free electron laser (IFEL) accelerator driven by a CO{sub 2} laser. The design and simulations for two phases of this experiment including demonstration of 10 MeV and 100 MeV acceleration are presented. (author)

  7. Traveling Wave Accelerating Structure for a Superconducting Accelerator

    CERN Document Server

    Kanareykin, Alex; Solyak, Nikolay

    2005-01-01

    We are presenting a superconducting traveling wave accelerating structure (STWA) concept, which may prove to be of crucial importance to the International Linear Collider. Compared to the existing design of a TESLA cavity, the traveling wave structure can provide ~20-40% higher accelerating gradient for the same aperture and the same peak surface magnetic RF field. The recently achieved SC structure gradient of 35 MV/m can be increased up to ~50 MV/m with the new STWA structure design. The STWA structure is supposed to be installed into the superconducting resonance ring and is fed by the two couplers with appropriate phase advance to excite a traveling wave inside the structure. The system requires two independent tuners to be able to adjust the cavity and feedback waveguide frequencies and hence to reduce the unwanted backward wave. In this presentation we discuss the structure design, optimization of the parameters, tuning requirements and plans for further development.

  8. Acceleration of liquid by boiling of other volatile liquid, (4)

    International Nuclear Information System (INIS)

    Hijikata, Kunio; Mori, Yasuo

    1978-01-01

    In the development of liquid metal MHD power generation using liquid metal as a working fluid, it is one of the important problems to accelerate liquid metal efficiently by means of thermal energy. Though various accelerating methods have been proposed so far, those do not provide high cycle thermal efficiency because of either small electric conductivity, low accelerating efficiency or low gas-liquid separating efficiency. The authors proposed the method to accelerate through volume expansion by boiling a volatile liquid being blown into liquid metal at high temperature, and have investigated it experimentally and theoretically. In the study, efficiency has been discussed in case of the acceleration of fluid subjected to magneto-hydrodynamical force by boiling of droplets of other liquid. Theoretically, the field of flow and two-phase cycle and gas phase cycle were analyzed. The report describes on these results and discussions. It is concluded that efficiency is independent of the injected amount and position of droplets, final efficiency is little affected by external load and thermal conductivity of volatile liquid droplets, the efficiency for the combination of cesium and lead is about 50%, and the method proposed by authors seems to be better than the conventional methods with gas phase cycle proposed so far using inert gas bubbles in lieu of volatile liquid. (Wakatsuki, Y.)

  9. Proton linear accelerators: A theoretical and historical introduction

    International Nuclear Information System (INIS)

    Lapostolle, P.M.

    1989-07-01

    From the beginning, the development of linear accelerators has followed a number of different directions. This report surveys the basic ideas and general principles of such machines, pointing out the problems that have led to the various improvements, with the hope that it may also aid further progress. After a brief historical survey, the principal aspects of accelerator theory are covered in some detail: phase stability, focusing, radio-frequency accelerating structures, the detailed calculation of particle dynamics, and space-charge effects at high intensities. These developments apply essentially to proton and ion accelerators, and only the last chapter deals with a few aspects relative to electrons. 134 refs

  10. Influence of treadmill acceleration on actual walk-to-run transition.

    Science.gov (United States)

    Van Caekenberghe, I; Segers, V; De Smet, K; Aerts, P; De Clercq, D

    2010-01-01

    When accelerating continuously, humans spontaneously change from a walking to a running pattern by means of a walk-to-run transition (WRT). Results of previous studies indicate that when higher treadmill accelerations are imposed, higher WRT-speeds can be expected. By studying the kinematics of the WRT at different accelerations, the underlying mechanisms can be unravelled. 19 young, healthy female subjects performed walk-to-run transitions on a constantly accelerating treadmill (0.1, 0.2 and 0.5 m s(-2)). A higher acceleration induced a higher WRT-speed, by effecting the preparation of transition, as well as the actual transition step. Increasing the acceleration caused a higher WRT-speed as a result of a greater step length during the transition step, which was mainly a consequence of a prolonged airborne phase. Besides this effect on the transition step, the direct preparation phase of transition (i.e. the last walking step before transition) appeared to fulfil specific constraints required to execute the transition regardless of the acceleration imposed. This highlights an important role for this step in the debate regarding possible determinants of WRT. In addition spatiotemporal and kinematical data confirmed that WRT remains a discontinuous change of gait pattern in all accelerations imposed. It is concluded that the walk-to-run transition is a discontinuous switch from walking to running which depends on the magnitude of treadmill belt acceleration. Copyright 2009 Elsevier B.V. All rights reserved.

  11. The accelerating effect of chitosan-silica hybrid dressing materials on the early phase of wound healing.

    Science.gov (United States)

    Park, Ji-Ung; Jung, Hyun-Do; Song, Eun-Ho; Choi, Tae-Hyun; Kim, Hyoun-Ee; Song, Juha; Kim, Sukwha

    2017-10-01

    Commercialized dressing materials with or without silver have played a passive role in early-phase wound healing, protecting the skin defects from infections, absorbing exudate, and preventing dehydration. Chitosan (CTS)-based sponges have been developed in pure or hybrid forms for accelerating wound healing, but their wound-healing capabilities have not been extensively compared with widely used commercial dressing materials, providing limited information in a practical aspect. In this study, we have developed CTS-silica (CTS-Si) hybrid sponges with water absorption, flexibility, and mechanical behavior similar to those of CTS sponges. In vitro and in vivo tests were performed to compare the CTS-Si sponges with three commercial dressing materials [gauze, polyurethane (PU), and silver-containing hydrofiber (HF-Ag)] in addition to CTS sponges. Both in vitro and in vivo tests showed that CTS-Si sponges promoted fibroblast proliferation, leading to accelerated collagen synthesis, whereas the CTS sponges did not exhibit significant differences in fibroblast proliferation and collagen synthesis from gauze, PU, and HF-Ag sponges. In case of CTS-Si, the inflammatory cells were actively recruited to the wound by the influence of the released silicon ions from CTS-Si sponges, which, in return, led to an enhanced secretion of growth factors, particularly TGF-β during the early stage. The higher level of TGF-β likely improved the proliferation of fibroblasts, and as a result, collagen synthesis by fibroblasts became remarkably productive, thereby increasing collagen density at the wound site. Therefore, the CTS-Si hybrid sponges have considerable potential as a wound-dressing material for accelerating wound healing. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1828-1839, 2017. © 2016 Wiley Periodicals, Inc.

  12. Interplay between topological phase and self-acceleration in a vortex symmetric Airy beam.

    Science.gov (United States)

    Fang, Zhao-Xiang; Chen, Yue; Ren, Yu-Xuan; Gong, Lei; Lu, Rong-De; Zhang, An-Qi; Zhao, Hong-Ze; Wang, Pei

    2018-03-19

    Photons in an optical vortex usually carry orbital angular momentum, which boosts the application of the micro-rotation of absorbing particles and quantum information encoding. Such photons propagate along a straight line in free space or follow a curved trace once guided by an optical fiber. Teleportation of an optical vortex using a beam with non-diffraction and self-healing is quite challenging. We demonstrate the manipulation of the propagation trace of an optical vortex with a symmetric Airy beam (SAB) and found that the SAB experiences self-rotation with the implementation of a topological phase structure of coaxial vortex. Slight misalignment of the vortex and the SAB enables the guiding of the vortex into one of the self-accelerating channels. Multiple off-axis vortices embedded in SAB are also demonstrated to follow the trajectory of the major lobe for the SAB beam. The Poynting vector for the beams proves the direction of the energy flow corresponding to the intensity distribution. Hence, we anticipate that the proposed vortex symmetric Airy beam (VSAB) will provide new possibilities for optical manipulation and optical communication.

  13. Low-level RF control system issues for an ADTT accelerator

    International Nuclear Information System (INIS)

    Ziomek, C.D.; Regan, A.H.; Lynch, M.T.; Bowling, P.S.

    1994-01-01

    The RF control system for a charged-particle accelerator must maintain the correct amplitude and phase of RF field inside the accelerator cavity in the presence of perturbations, noises, and time varying system components. For an accelerator with heavy beam-loading, fluctuations in the beam current cause large perturbations to the RF field amplitude and phase that must be corrected by the RF control system. The ADTT applications require a high-current, heavily beam-loaded, continuous-wave (CW) accelerator. Additional concerns created by the CW operation include system start-up, beam interruption, and fault recovery. Also, the RF control system for an ADTT facility must include sophisticated automation to reduce the operator interaction and support. This paper describes an RF control system design that addresses these various issues by evaluation a combination of feedback and feed forward control techniques. Experience from the high-current Ground Test Accelerator (GTA) is drawn upon for this RF control system design. Comprehensive computer modeling with the Matrix x software has been used to predict the performance of this RF control system

  14. Accelerated re-epithelialization of partial-thickness skin wounds by a topical betulin gel: Results of a randomized phase III clinical trials program.

    Science.gov (United States)

    Barret, Juan P; Podmelle, Fred; Lipový, Břetislav; Rennekampff, Hans-Oliver; Schumann, Hauke; Schwieger-Briel, Agnes; Zahn, Tobias R; Metelmann, Hans-Robert

    2017-09-01

    The clinical significance of timely re-epithelialization is obvious in burn care, since delayed wound closure is enhancing the risk of wound site infection and extensive scarring. Topical treatments that accelerate wound healing are urgently needed to reduce these sequelae. Evidence from preliminary studies suggests that betulin can accelerate the healing of different types of wounds, including second degree burns and split-thickness skin graft wounds. The goal of this combined study program consisting of two randomized phase III clinical trials in parallel is to evaluate whether a topical betulin gel (TBG) is accelerating re-epithelialization of split-thickness skin graft (STSG) donor site wounds compared to standard of care. Two parallel blindly evaluated, randomised, controlled, multicentre phase III clinical trials were performed in adults undergoing STSG surgery (EudraCT nos. 2012-003390-26 and 2012-000777-23). Donor site wounds were split into two equal halves and randomized 1:1 to standard of care (a non-adhesive moist wound dressing) or standard of care plus TBG consisting of 10% birch bark extract and 90% sunflower oil (Episalvan, Birken AG, Niefern-Oeschelbronn, Germany). The primary efficacy assessment was the intra-individual difference in time to wound closure assessed from digital photographs by three blinded experts. A total of 219 patients were included and treated in the two trials. Wounds closed faster with TBG than without it (15.3 vs. 16.5 days; mean intra-individual difference=-1.1 days [95% CI, -1.5 to -0.7]; p<0.0001). This agreed with unblinded direct clinical assessment (difference=-2.1 days [95% CI, -2.7 to -1.5]; p<0.0001). Adverse events possibly related to treatment were mild or moderate and mostly at the application site. TBG accelerates re-epithelialization of partial thickness wounds compared to the current standard of care, providing a well-tolerated contribution to burn care in practice. Copyright © 2017 The Authors. Published by

  15. Immunological dynamics associated with rapid virological response during the early phase of type I interferon therapy in patients with chronic hepatitis C.

    Science.gov (United States)

    Lee, Jae-Won; Kim, Won; Kwon, Eun-Kyung; Kim, Yuri; Shin, Hyun Mu; Kim, Dong-Hyun; Min, Chan-Ki; Choi, Ji-Yeob; Lee, Won-Woo; Choi, Myung-Sik; Kim, Byeong Gwan; Cho, Nam-Hyuk

    2017-01-01

    Type I interferons (IFNs) play an important role in antiviral immunity as well as immunopathogenesis of diverse chronic viral infections. However, the precise mechanisms regulating the multifaceted effects of type I IFNs on the immune system and pathological inflammation still remain unclear. In order to assess the immunological dynamics associated with rapid viral clearance in chronic hepatitis C patients during the acute phase of type I IFN therapy, we analyzed multiple parameters of virological and immunological responses in a cohort of 59 Korean hepatitis C patients who received pegylated IFN-α and ribavirin (IFN/RBV). Most of the Korean patients had favorable alleles in the IFN-λ loci for responsiveness to IFN/RBV (i.e., C/C in rs12979860, T/T in rs8099917, and TT/TT in rs368234815). Rapid virological response (RVR) was determined mainly by the hepatitis C virus genotype. Among the cytokines analyzed, higher plasma levels of IL-17A and FGF were observed in non-RVR patients infected with viral genotype 1 and IP-10 was consistently elevated in RVR group infected with genotype 2 during the early phase of antiviral therapy. In addition, these three cytokines were correlated each other, suggesting a functional linkage of the cytokines in antiviral responses during IFN/RBV therapy. A low baseline frequencies of regulatory T cells and γδ T cells, but high level of group 2 innate lymphoid cells, in peripheral bloods were also significantly associated with the RVR group, implicating a potential role of the cellular immunity during the early phase of IFN/RBV therapy. Therefore, the immunological programs established by chronic hepatitis C and rapid disruption of the delicate balance by exogenous type I IFN might be associated with the subsequent virological outcomes in chronic hepatitis C patients.

  16. Laser acceleration

    Science.gov (United States)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-02-01

    The fundamental idea of Laser Wakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wakefields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ˜ c and ultrafastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nanomaterials is also emerging.

  17. Laser acceleration

    International Nuclear Information System (INIS)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-01-01

    The fundamental idea of LaserWakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wake fields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ∼ c and ultra fastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nano materials is also emerging.

  18. Improved detection of chronic myocardial infarction with Fourier amplitude and phase imaging in two projections

    International Nuclear Information System (INIS)

    Akins, E.W.; Scott, E.A.; Williams, C.M.

    1987-01-01

    Twenty-seven patients with 33 chronic myocaridal infarctions underwent MR imaging and radionuclide ventriculography at rest. The radionuclide ventriculographs, in left anterior oblique (LAO) and left posterior oblique (LPO) projections, were analyzed by two independent observers by visual inspection and combined Fourier-transformed amplitude and phase imaging. Only 15 (45%) of the 33 infarctions were detected by visual inspection, but 21 (64%) were detected on the LAO Fourier-transformed images along. Thirty (91%) were detected by using both LAO and LPO Fourier-transformed images. On MR imaging, 28 (85%) of the myocardial infarctions appeared as areas of focal wall thinning. Combined Fourier-transformed amplitude and phase imaging in both LAO and LPO views discloses more myocardial infarctions than visual inspection or LAO Fourier-transformed images alone because inferior infarctions, which are frequently missed in the LAO view, are easily seen in the LPO view

  19. Wakeless triple soliton accelerator

    International Nuclear Information System (INIS)

    Mima, K.; Ohsuga, T.; Takabe, H.; Nishihara, K.; Tajima, T.; Zaidman, E.; Horton, W.

    1986-09-01

    We introduce and analyze the concept of a wakeless triple soliton accelerator in a plasma fiber. Under appropriate conditions the triple soliton with two electromagnetic and one electrostatic waves in the beat-wave resonance propagates with velocity c leaving no plasma wake behind, while the phase velocity of the electrostatic wave is made also c in the fiber

  20. Phase and amplitude control system for Stanford Linear Accelerator

    International Nuclear Information System (INIS)

    Yoo, S.J.

    1983-01-01

    The computer controlled phase and amplitude detection system measures the instantaneous phase and amplitude of a 1 micro-second 2856 MHz rf pulse at a 180 Hz rate. This will be used for phase feedback control, and also for phase and amplitude jitter measurement. The program, which was originally written by John Fox and Keith Jobe, has been modified to improve the function of the system. The software algorithms used in the measurement are described, as is the performance of the prototype phase and amplitude detector system

  1. Ionization and pulse lethargy effects in inverse Cherenkov accelerators

    International Nuclear Information System (INIS)

    Sprangle, P.; Hubbard, R.F.; Hafizi, B.

    1997-01-01

    Ionization processes limit the accelerating gradient and place an upper limit on the pulse duration of the electromagnetic driver in the inverse Cherenkov accelerator (ICA). Group velocity slippage, i.e., pulse lethargy, on the other hand, imposes a lower limit on the pulse duration. These limits are obtained for two ICA configurations in which the electromagnetic driver (e.g., laser or millimeter wave source) is propagated in a waveguide that is (i) lined with a dielectric material or (ii) filled with a neutral gas. In either configuration the electromagnetic driving field is guided and has an axial electric field with phase velocity equal to the speed of light in vacuum, c. The intensity of the driver in the ICA, and therefore the acceleration gradient, is limited by tunneling and collisional ionization effects. Partial ionization of the dielectric liner or gas can lead to significant modification of the dispersive properties of the waveguide, altering the phase velocity of the accelerating field and causing particle slippage, thus disrupting the acceleration process. An additional limitation on the pulse duration is imposed since the group velocity of the driving pulse is less than c and the pulse slips behind the accelerated electrons. Hence for sufficiently short pulses the electrons outrun the pulse, terminating the acceleration. Limitations on the driver pulse duration and accelerating gradient, due to ionization and pulse lethargy, are estimated for the two ICA configurations. Maximum accelerating gradients and pulse durations are presented for a 10 μm, 1 mm, and 1 cm wavelength electromagnetic driver. The combination of ionization and pulse lethargy effects impose severe limitations on the maximum energy gain in inverse Cherenkov accelerators. copyright 1997 The American Physical Society

  2. Thermodynamics of Accelerating Black Holes.

    Science.gov (United States)

    Appels, Michael; Gregory, Ruth; Kubizňák, David

    2016-09-23

    We address a long-standing problem of describing the thermodynamics of an accelerating black hole. We derive a standard first law of black hole thermodynamics, with the usual identification of entropy proportional to the area of the event horizon-even though the event horizon contains a conical singularity. This result not only extends the applicability of black hole thermodynamics to realms previously not anticipated, it also opens a possibility for studying novel properties of an important class of exact radiative solutions of Einstein equations describing accelerated objects. We discuss the thermodynamic volume, stability, and phase structure of these black holes.

  3. Advanced Beamline Design for Fermilab's Advanced Superconducting Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Christopher [Northern Illinois Univ., DeKalb, IL (United States)

    2014-01-01

    The Advanced Superconducting Test Accelerator (ASTA) at Fermilab is a new electron accelerator currently in the commissioning stage. In addition to testing superconducting accelerating cavities for future accelerators, it is foreseen to support a variety of Advanced Accelerator R&D (AARD) experiments. Producing the required electron bunches with the expected flexibility is challenging. The goal of this dissertation is to explore via numerical simulations new accelerator beamlines that can enable the advanced manipulation of electron bunches. The work especially includes the design of a low-energy bunch compressor and a study of transverse-to-longitudinal phase space exchangers.

  4. CO2 laser technology for advanced particle accelerators. Revision

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.

    1996-06-01

    Short-pulse, high-power CO 2 lasers open new prospects for development of ultra-high gradient laser-driven electron accelerators. The advantages of λ=10 μm CO 2 laser radiation over the more widely exploited solid state lasers with λ∼1 μm are based on a λ 2 -proportional ponderomotive potential, λ-proportional phase slippage distance, and λ-proportional scaling of the laser accelerator structures. We show how a picosecond terawatt CO 2 laser that is under construction at the Brookhaven Accelerator Test Facility may benefit the ATF's experimental program of testing far-field, near-field, and plasma accelerator schemes

  5. Photon acceleration in laser wakefield accelerators

    International Nuclear Information System (INIS)

    Trines, R. M. G. M.

    2007-01-01

    If the index of a refraction of a dispersive medium, such as a plasma, changes in time, it can be used to change the frequency of light propagating through the medium. This effect is called photon acceleration. It has been predicted in both theory and simulations, and also been demonstrated experimentally for the case of moving ionization fronts in gases (the so-called ionization blueshift) as well as for laser-driven wakefields.Here, we present studies of photon acceleration in laser-driven plasma wakefields. The unique spectral characteristics of this process will be discussed, to distinguish it from e.g. photon acceleration by ionization fronts, frequency domain interferometry or self-phase modulation. The dynamics of the photons in laser-wakefield interaction are studied through both regular particle-in-cell and wave-kinetic simulations. The latter approach provides a powerful, versatile, and easy-to-use method to track the propagation of individual spectral components, providing new insight into the physics of laser-plasma interaction. Theory, simulations and experimental results will be brought together to provide a full understanding of the dynamics of a laser pulse in its own wakefield.Even though the wave-kinetic approach mentioned above has mainly been developed for the description of laser-plasma interaction, it can be applied to a much wider range of fast wave-slow wave interaction processes: Langmuir waves-ion acoustic waves, drift waves-zonal flow, Rossby waves-zonal flow, or even photons-gravitational waves. Several recent results in these areas will be shown, often with surprising results

  6. Extensions of MAD Version 8 to Include Beam Acceleration

    International Nuclear Information System (INIS)

    Raubenheimer, Tor O

    2000-01-01

    In this paper, the authors describe modifications to MAD version 8.23 to include linear accelerator cavities and beam acceleration. An additional energy variable has been added which is modified as the beam passes through LCAV elements (linear accelerator cavities) and can be used as a constraint in matching commands. The calculation of the beta functions and phase advance is consistent with that in other codes that treat acceleration such as TRANSPORT or DIMAD. These modifications allow this version of MAD to be used for the design and modeling of linacs and the authors present examples from the Next Linear Collider design as well as a muon acceleration complex. The code is available from CERN or SLAC

  7. Phase synchronization of multiple klystrons in RF system

    International Nuclear Information System (INIS)

    Kwon, S.; Regan, A.; Wang, Y.M.; Rohlev, T.

    1998-01-01

    The Low Energy Demonstration Accelerator (LEDA) being constructed at Los Alamos National Laboratory will serve as the prototype for the low energy section of the Acceleration Production of Tritium (APT) accelerator. The first LEDA RF system includes three, 1.2 MW, 350 MHz, continuous wave, klystrons driving a radio frequency quadrupole (RFQ). A phase control loop is necessary for each individual klystron in order to guarantee the phase matching of these klystrons. To meet this objective, they propose adaptive PI controllers which are based on simple adaptive control. These controllers guarantee not only phase matching but also amplitude matching

  8. Fischer Indole Synthesis in the Gas Phase, the Solution Phase, and at the Electrospray Droplet Interface.

    Science.gov (United States)

    Bain, Ryan M; Ayrton, Stephen T; Cooks, R Graham

    2017-07-01

    Previous reports have shown that reactions occurring in the microdroplets formed during electrospray ionization can, under the right conditions, exhibit significantly greater rates than the corresponding bulk solution-phase reactions. The observed acceleration under electrospray ionization could result from a solution-phase, a gas-phase, or an interfacial reaction. This study shows that a gas-phase ion/molecule (or ion/ion) reaction is not responsible for the observed rate enhancement in the particular case of the Fischer indole synthesis. The results show that the accelerated reaction proceeds in the microdroplets, and evidence is provided that an interfacial process is involved. Graphical Abstract GRAPHICAL ABSTRACT TEXT HERE] -->.

  9. Machine Protection: Availability for Particle Accelerators

    CERN Document Server

    Apollonio, Andrea; Schmidt, Ruediger

    2015-03-16

    Machine availability is a key indicator for the performance of the next generation of particle accelerators. Availability requirements need to be carefully considered during the design phase to achieve challenging objectives in different fields, as e.g. particle physics and material science. For existing and future High-Power facilities, such as ESS (European Spallation Source) and HL-LHC (High-Luminosity LHC), operation with unprecedented beam power requires highly dependable Machine Protection Systems (MPS) to avoid any damage-induced downtime. Due to the high complexity of accelerator systems, finding the optimal balance between equipment safety and accelerator availability is challenging. The MPS architecture, as well as the choice of electronic components, have a large influence on the achievable level of availability. In this thesis novel methods to address the availability of accelerators and their protection systems are presented. Examples of studies related to dependable MPS architectures are given i...

  10. A Phase I Study of Short-Course Accelerated Whole Brain Radiation Therapy for Multiple Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Caravatta, Luciana; Deodato, Francesco; Ferro, Marica [Department of Radiation Oncology, Fondazione di Ricerca e Cura ' Giovanni Paolo II' , Universita Cattolica del S. Cuore, Campobasso (Italy); Macchia, Gabriella, E-mail: gmacchia@rm.unicatt.it [Department of Radiation Oncology, Fondazione di Ricerca e Cura ' Giovanni Paolo II' , Universita Cattolica del S. Cuore, Campobasso (Italy); Massaccesi, Mariangela [Department of Radiation Oncology, Fondazione di Ricerca e Cura ' Giovanni Paolo II' , Universita Cattolica del S. Cuore, Campobasso (Italy); Cilla, Savino [Medical Physics Unit, Fondazione di Ricerca e Cura ' Giovanni Paolo II,' Universita Cattolica del S. Cuore, Campobasso (Italy); Padula, Gilbert D.A. [Department of Radiation Oncology, The Lacks Cancer Center Saint Mary' s Health Care, Grand Rapids, Michigan (United States); Mignogna, Samantha; Tambaro, Rosa [Department of Palliative Therapies, Fondazione di Ricerca e Cura ' Giovanni Paolo II' , Universita Cattolica del S. Cuore, Campobasso (Italy); Carrozza, Francesco [Department of Oncology, A. Cardarelli Hospital, Campobasso (Italy); Flocco, Mariano [Madre Teresa di Calcutta Hospice, Larino (Italy); Cantore, Giampaolo [Department of Neurological Sciences, Istituto Neurologico Mediterraneo Neuromed, Istituto di Ricovero e Cura a Carattere Scientifico, Pozzilli (Italy); Scapati, Andrea [Department of Radiation Oncology, ' San Francesco' Hospital, Nuoro (Italy); Buwenge, Milly [Department of Radiotherapy, Mulago Hospital, Kampala (Uganda); and others

    2012-11-15

    Purpose: To define the maximum tolerated dose (MTD) of a SHort-course Accelerated whole brain RadiatiON therapy (SHARON) in the treatment of patients with multiple brain metastases. Methods and Materials: A phase 1 trial in 4 dose-escalation steps was designed: 12 Gy (3 Gy per fraction), 14 Gy (3.5 Gy per fraction), 16 Gy (4 Gy per fraction), and 18 Gy (4.5 Gy per fraction). Eligibility criteria included patients with unfavorable recursive partitioning analysis (RPA) class > or =2 with at least 3 brain metastases or metastatic disease in more than 3 organ systems, and Eastern Cooperative Oncology Group (ECOG) performance status {<=}3. Treatment was delivered in 2 days with twice-daily fractionation. Patients were treated in cohorts of 6-12 to define the MTD. The dose-limiting toxicity (DLT) was defined as any acute toxicity {>=}grade 3, according to the Radiation Therapy Oncology Group scale. Information on the status of the main neurologic symptoms and quality of life were recorded. Results: Characteristics of the 49 enrolled patients were as follows: male/female, 30/19; median age, 66 years (range, 23-83 years). ECOG performance status was <3 in 46 patients (94%). Fourteen patients (29%) were considered to be in recursive partitioning analysis (RPA) class 3. Grade 1-2 acute neurologic (26.4%) and skin (18.3%) toxicities were recorded. Only 1 patient experienced DLT (neurologic grade 3 acute toxicity). With a median follow-up time of 5 months (range, 1-23 months), no late toxicities have been observed. Three weeks after treatment, 16 of 21 symptomatic patients showed an improvement or resolution of presenting symptoms (overall symptom response rate, 76.2%; confidence interval 0.95: 60.3-95.9%). Conclusions: Short-course accelerated radiation therapy in twice-daily fractions for 2 consecutive days is tolerated up to a total dose of 18 Gy. A phase 2 study has been planned to evaluate the efficacy on overall survival, symptom control, and quality of life indices.

  11. Association of phase angle on bioelectrical impedance analysis and dialysis frequency with survival of chronic hemodialysis patients

    Science.gov (United States)

    Muzasti, R. A.; Lubis, H. R.

    2018-03-01

    Phase angle, a parameter by Bioelectrical Impedance Analysis, can detect body composition changes, so it can be used as a prognostic indicator in some chronic conditions. This study was for determining the relationship between PhA and hemodiálisis frequency with the survival of chronic hemodiálisis patients. This longitudinal retrospective study involved 173 chronic hemodiálisis patients at Rasyida Renal Hospital. The Kaplan-Meier method is used to determine the survival. Cox proportional hazard analysis is used to determine which variables significantly increase mortality. During the study period, 89 patients underwent hemodiálysis 3x a week (4 hours/session), and 84 patients underwent HD 2x a week (5 hours/session). Demographic and clinical characteristics in both groups were similar. There was no difference in PhA value in groups of 3x a week and group 2x a week (4.02 ± 1.13 vs 4.25 ± 1.12). Patients with twice a week hemodiálisis had a shorter survival than the 3x week group (35.14 ± 2.76 vs 38.62 ± 3.03) although it was not statistically significant (p = 0.126).

  12. Laser-plasma booster for ion post acceleration

    Directory of Open Access Journals (Sweden)

    Satoh D.

    2013-11-01

    Full Text Available A remarkable ion energy increase is demonstrated for post acceleration by a laser-plasma booster. An intense short-pulse laser generates a strong current by high-energy electrons accelerated, when this intense short-pulse laser illuminates a plasma target. The strong electric current creates a strong magnetic field along the high-energy electron current in plasma. During the increase phase in the magnetic field, a longitudinal inductive electric field is induced for the forward ion acceleration by the Faraday law. Our 2.5-dimensional particle-in-cell simulations demonstrate a remarkable increase in ion energy by several tens of MeV.

  13. A practical guide to modern high energy particle accelerators

    International Nuclear Information System (INIS)

    Holmes, S.D.

    1987-10-01

    The purpose of these lectures is to convey an understanding of how particle accelerators work and why they look the way they do. The approach taken is physically intuitive rather than mathematically rigorous. The emphasis is on the description of proton circular accelerators and colliders. Linear accelerators are mentioned only in passing as sources of protons for higher energy rings. Electron accelerators/storage rings and antiproton sources are discussed only by way of brief descriptions of the features which distinguish them from proton accelerators. The basics of how generic accelerators work are discussed, focusing on descriptions of what sets the overall scale, single particle dynamics and stability, and descriptions of the phase space of the particle beam, the information thus presented is then used to go through the exercise of designing a Superconducting Super Collider

  14. The Importance of Assessing Nutritional Status to Ensure Optimal Recovery during the Chronic Phase of Stroke

    Directory of Open Access Journals (Sweden)

    Monica C. Serra

    2018-01-01

    Full Text Available Background. Despite evidence that many of the consequences of stroke that hinder recovery (i.e., obesity, muscle atrophy, and functional declines have nutritionally modifiable behavior components, little attention has been focused on the significance of nutrition beyond the acute phase of stroke. Objective. This literature review summarizes the evidence for and against the influence of nutrition on optimal recovery and rehabilitation in chronic (>6 months stroke. Results. The literature, which is mainly limited to cross-sectional studies, suggests that a suboptimal nutritional status, including an excess caloric intake, reduced protein intake, and micronutrient deficiencies, particularly the B-vitamins, vitamin D, and omega 3 fatty acids, may have deleterious effects on metabolic, physical, and psychological functioning in chronic stroke survivors. Conclusions. Careful evaluation of dietary intake, especially among those with eating disabilities and preexisting malnutrition, may aid in the identification of individuals at increased nutritional risk through which early intervention may benefit recovery and rehabilitation and prevent further complications after stroke.

  15. The Importance of Assessing Nutritional Status to Ensure Optimal Recovery during the Chronic Phase of Stroke.

    Science.gov (United States)

    Serra, Monica C

    2018-01-01

    Despite evidence that many of the consequences of stroke that hinder recovery (i.e., obesity, muscle atrophy, and functional declines) have nutritionally modifiable behavior components, little attention has been focused on the significance of nutrition beyond the acute phase of stroke. This literature review summarizes the evidence for and against the influence of nutrition on optimal recovery and rehabilitation in chronic (>6 months) stroke. The literature, which is mainly limited to cross-sectional studies, suggests that a suboptimal nutritional status, including an excess caloric intake, reduced protein intake, and micronutrient deficiencies, particularly the B-vitamins, vitamin D, and omega 3 fatty acids, may have deleterious effects on metabolic, physical, and psychological functioning in chronic stroke survivors. Careful evaluation of dietary intake, especially among those with eating disabilities and preexisting malnutrition, may aid in the identification of individuals at increased nutritional risk through which early intervention may benefit recovery and rehabilitation and prevent further complications after stroke.

  16. Nilotinib versus imatinib for newly diagnosed chronic myeloid leukemia

    DEFF Research Database (Denmark)

    Saglio, Giuseppe; Kim, Dong-Wook; Issaragrisil, Surapol

    2010-01-01

    Nilotinib has been shown to be a more potent inhibitor of BCR-ABL than imatinib. We evaluated the efficacy and safety of nilotinib, as compared with imatinib, in patients with newly diagnosed Philadelphia chromosome-positive chronic myeloid leukemia (CML) in the chronic phase.......Nilotinib has been shown to be a more potent inhibitor of BCR-ABL than imatinib. We evaluated the efficacy and safety of nilotinib, as compared with imatinib, in patients with newly diagnosed Philadelphia chromosome-positive chronic myeloid leukemia (CML) in the chronic phase....

  17. An economic analysis of high-dose imatinib, dasatinib, and nilotinib for imatinib-resistant chronic phase chronic myeloid leukemia in China: A CHEERS-compliant article.

    Science.gov (United States)

    Wu, Bin; Liu, Maobai; Li, Te; Lin, Houwen; Zhong, Hua

    2017-07-01

    The aim of the study was to test the cost-effectiveness of dasatinib compared to high-dose imatinib and nilotinib in Chinese patients who were diagnosed with imatinib-resistant chronic myeloid leukemia in the chronic phase (CML-CP). A Markov model combined with clinical effectiveness, utility, and cost data was used. The sensitivity analyses were conducted to determine the robustness of the model outcomes. The impact of patient assistance programs (PAPs) was assessed. Treatment with dasatinib is expected to produce 3.65, 0.59, and 0.15 more quality-adjusted life years (QALYs) in comparison with high-dose imatinib (600 and 800 mg) and nilotinib, respectively. When a PAP was available, dasatinib yielded an incremental cost of $16,417 per QALY compared to imatinib (600 mg) and was cost-saving compared to imatinib (800 mg) and nilotinib. When PAP is available in the Chinese setting, dasatinib is likely to be a cost-effective strategy for patients with CML-CP standard-dose imatinib resistance. The results should be carefully explained due to the assumptions and limitations used in the study.

  18. Impulsive phase of solar flares: theory

    International Nuclear Information System (INIS)

    Mackinnon, A.L.

    1986-01-01

    The paper reviews the theoretical interpretation of impulsive phase phenomena in solar flares. The impulsive phase is defined to be that period of approx. 10 - 100s duration, during which the flare radiative output undergoes its most rapid, dramatic increase and decrease. The interpretation of the various impulsive phase radiation signatures are examined, including the i) hard x-ray emission, ii) radio emission, iii) UV, Hα and white light emissions and iv) gamma-ray emission. The acceleration mechanisms are discussed with respect to candidate acceleration mechanisms, and the synthesis of the theory and observations. (UK)

  19. Standing-wave free-electron laser two-beam accelerator

    International Nuclear Information System (INIS)

    Sessler, A.M.; Whittum, D.H.; Wurtele, J.S.

    1991-01-01

    A free-electron laser (FEL) two-beam accelerator (TBA) is proposed, in which the FEL interaction takes place in a series of drive cavities, rather than in a waveguide. Each drive cavity is 'beat-coupled' to a section of the accelerating structure. This standing-wave TBA is investigated theoretically and numerically, with analyses included of microwave extraction, growth of the FEL signal through saturation, equilibrium longitudinal beam dynamics following saturation, and sensitivity of the microwave amplitude and phase to errors in current and energy. It is found that phase errors due to current jitter are substantially reduced from previous versions of the TBA. Analytic scalings and numerical simulations are used to obtain an illustrative TBA parameter set. (orig.)

  20. Sensitive detection of pre-existing BCR-ABL kinase domain mutations in CD34+ cells of newly diagnosed chronic-phase chronic myeloid leukemia patients is associated with imatinib resistance: implications in the post-imatinib era.

    Directory of Open Access Journals (Sweden)

    Zafar Iqbal

    Full Text Available BACKGROUND: BCR-ABL kinase domain mutations are infrequently detected in newly diagnosed chronic-phase chronic myeloid leukemia (CML patients. Recent studies indicate the presence of pre-existing BCR-ABL mutations in a higher percentage of CML patients when CD34+ stem/progenitor cells are investigated using sensitive techniques, and these mutations are associated with imatinib resistance and disease progression. However, such studies were limited to smaller number of patients. METHODS: We investigated BCR-ABL kinase domain mutations in CD34+ cells from 100 chronic-phase CML patients by multiplex allele-specific PCR and sequencing at diagnosis. Mutations were re-investigated upon manifestation of imatinib resistance using allele-specific PCR and direct sequencing of BCR-ABL kinase domain. RESULTS: Pre-existing BCR-ABL mutations were detected in 32/100 patients and included F311L, M351T, and T315I. After a median follow-up of 30 months (range 8-48, all patients with pre-existing BCR-ABL mutations exhibited imatinib resistance. Of the 68 patients without pre-existing BCR-ABL mutations, 24 developed imatinib resistance; allele-specific PCR and BCR-ABL kinase domain sequencing detected mutations in 22 of these patients. All 32 patients with pre-existing BCR-ABL mutations had the same mutations after manifestation of imatinib-resistance. In imatinib-resistant patients without pre-existing BCR-ABL mutations, we detected F311L, M351T, Y253F, and T315I mutations. All imatinib-resistant patients except T315I and Y253F mutations responded to imatinib dose escalation. CONCLUSION: Pre-existing BCR-ABL mutations can be detected in a substantial number of chronic-phase CML patients by sensitive allele-specific PCR technique using CD34+ cells. These mutations are associated with imatinib resistance if affecting drug binding directly or indirectly. After the recent approval of nilotinib, dasatinib, bosutinib and ponatinib for treatment of chronic myeloid

  1. 100 MeV laser accelerator demonstration and 1 GeV baseline design development. 1992 Annual report

    International Nuclear Information System (INIS)

    1992-01-01

    The acceleration of relativistic electrons using the inverse Cerenkov effect was first demonstrated at Stanford University in 1981. Later, Fontana and Pantell developed an improved configuration for the inverse Cerenkov acceleration (ICA) process. A radially polarized laser beam is focused by an axicon onto the e-beam traveling through a gas-filled interaction region. The light intersects the e-beam at the Cerenkov angle θ c , where θ c = cos -1 (1/nβ), n is the index of refraction of the gas, and β is the ratio of the electron velocity to the speed of light. The goal of the present program is to demonstrate improved laser acceleration using the Fontana and Pantell configuration. The experiments will be performed on the Accelerator Test Facility (ATF) located at Brookhaven National Laboratory (BNL). This facility features a 50 MeV linac fed by a Nd:YAG (4ω) laser-driven photocathode e-gun. It will be upgraded to 65 MeV in the near future. The ATF also has a high peak power CO 2 laser, which was developed for laser acceleration studies. The present ICA experiment was divided into two phases. Phase 1 was to examine certain experimental issues in preparation for Phase 2. Phase 1 was successfully completed in the spring of 1992. Phase 2 is to perform the actual laser acceleration experiments on the ATF e-beam. The authors are currently waiting for the availability of the e-beam so that they can begin the Phase 2 experiments. In this section, the theory and experimental hardware for the present program are described. The results of the Phase 1 experiments are presented, and an update on the Phase 2 experiment is given

  2. [Challenges of lopinavir/ritonavir in the chronicity of human immunodeficiency virus infection].

    Science.gov (United States)

    Aguirrebengoa, Koldo

    2014-11-01

    Combination antiretroviral therapy (ART) has increased patient survival, which is currently similar to that of the general population in western countries. However, ART is unable to completely restore normal health, given the persistence of chronic immune activation. Human immunodeficiency virus (HIV) infection has become a chronic disease and 50% of patients will soon be older than 50 years. Currently, there is a debate on the possibility of accelerated aging in the HIV-infected population. An overlap has been observed between chronic inflammation, age-related comorbidities, lifestyle, and the long-term toxicity of ART. ART-related toxicity can encourage the development of comorbidities, especially cardiovascular and renal complications, while toxicity-especially that of thymidine analogs-can also contribute to inflammation and aging. Evidence is available on simplification strategies with boosted protease inhibitor monotherapy aiming to avoid or reduce potential or demonstrated toxicity. Currently, studies are underway of dual therapy strategies with lopinavir/ritonavir (LPV/r) with distinct antiretroviral agents. The studies with the largest samples are those with raltegravir and lamivudine. The GARDEL trial has demonstrated that dual therapy with LPV/r plus a generic drug such as lamivudine is non-inferior to triple therapy in treatment- naïve patients. All of the above indicates the response to the challenge posed to LPV/r by the chronic phase of the disease and by the need to reduce costs. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  3. Improved Magnetron Stability and Reduced Noise in Efficient Transmitters for Superconducting Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Kazakevich, G. [MUONS Inc., Batavia; Johnson, R. [MUONS Inc., Batavia; Lebedev, V. [Fermilab; Yakovlev, V. [Fermilab

    2018-04-01

    State of the art high-current superconducting accelerators require efficient RF sources with a fast dynamic phase and power control. This allows for compensation of the phase and amplitude deviations of the accelerating voltage in the Superconducting RF (SRF) cavities caused by microphonics, etc. Efficient magnetron transmitters with fast phase and power control are attractive RF sources for this application. They are more cost effective than traditional RF sources such as klystrons, IOTs and solid-state amplifiers used with large scale accelerator projects. However, unlike traditional RF sources, controlled magnetrons operate as forced oscillators. Study of the impact of the controlling signal on magnetron stability, noise and efficiency is therefore important. This paper discusses experiments with 2.45 GHz, 1 kW tubes and verifies our analytical model which is based on the charge drift approximation.

  4. A PAF receptor antagonist inhibits acute airway inflammation and late-phase responses but not chronic airway inflammation and hyperresponsiveness in a primate model of asthma

    Directory of Open Access Journals (Sweden)

    R. H. Gundel

    1992-01-01

    Full Text Available We have examined the effects of a PAF receptor antagonist, WEB 2170, on several indices of acute and chronic airway inflammation and associated changes in lung function in a primate model of allergic asthma. A single oral administration WEB 2170 provided dose related inhibition of the release of leukotriene C4 (LTC4 and prostaglandin D2 (PGD2 recovered and quantified in bronchoalveolar lavage (BAL fluid obtained during the acute phase response to inhaled antigen. In addition, oral WEB 2170 treatment in dual responder primates blocked the acute influx of neutrophils into the airways as well as the associated late-phase airway obstruction occurring 6 h after antigen inhalation. In contrast, a multiple dosing regime with WEB 2170 (once a day for 7 consecutive days failed to reduce the chronic airway inflammation (eosinophilic and associated airway hyperresponsiveness to inhaled methacholine that is characteristic of dual responder monkeys. Thus, we conclude that the generation of PAF following antigen inhalation contributes to the development of lipid mediators, acute airway inflammation and associated late-phase airway obstruction in dual responder primates; however, PAF does not play a significant role in the maintenance of chronic airway inflammation and associated airway hyperresponsiveness in this primate model.

  5. Research Update: Retardation and acceleration of phase separation evaluated from observation of imbalance between structure and valence in LiFePO4/FePO4 electrode

    Directory of Open Access Journals (Sweden)

    Kazuya Tokuda

    2014-07-01

    Full Text Available LiFePO4 is a potential positive electrode material for lithium ion batteries. We have experimentally observed an imbalance between the valence change of Fe ions and the structure change from the LiFePO4 phase to the FePO4 phase during delithiation by simultaneous in situ XRD and XANES measurements in an LiFePO4/FePO4 electrode. The ratio of structure change to valence change clearly indicates that the phase separation from LiFePO4 to FePO4 is suppressed at the beginning of delithiation, while it is accelerated at the latter stage, which is due to the coherent strain caused by the lattice misfit between the two phases.

  6. Super High Energy Colliding Beam Accelerators

    International Nuclear Information System (INIS)

    Abdelaziz, M.E.

    2009-01-01

    This lecture presents a review of cyclic accelerators and their energy limitations. A description is given of the phase stability principle and evolution of the synchrotron, an accelerator without energy limitation. Then the concept of colliding beams emerged to yield doubling of the beam energy as in the Tevatron 2 trillion electron volts (TeV) proton collider at Fermilab and the Large Hadron Collider (LHC) which is now planned as a 14-TeV machine in the 27 kilometer tunnel of the Large Electron Positron (LEP) collider at CERN. Then presentation is given of the Superconducting Supercollider (SSC), a giant accelerator complex with energy 40-TeV in a tunnel 87 kilometers in circumference under the country surrounding Waxahachie in Texas, U.S.A. These superhigh energy accelerators are intended to smash protons against protons at energy sufficient to reveal the nature of matter and to consolidate the prevailing general theory of elementary particle.

  7. Ponatinib versus imatinib for newly diagnosed chronic myeloid leukaemia: an international, randomised, open-label, phase 3 trial.

    Science.gov (United States)

    Lipton, Jeffrey H; Chuah, Charles; Guerci-Bresler, Agnès; Rosti, Gianantonio; Simpson, David; Assouline, Sarit; Etienne, Gabriel; Nicolini, Franck E; le Coutre, Philipp; Clark, Richard E; Stenke, Leif; Andorsky, David; Oehler, Vivian; Lustgarten, Stephanie; Rivera, Victor M; Clackson, Timothy; Haluska, Frank G; Baccarani, Michele; Cortes, Jorge E; Guilhot, François; Hochhaus, Andreas; Hughes, Timothy; Kantarjian, Hagop M; Shah, Neil P; Talpaz, Moshe; Deininger, Michael W

    2016-05-01

    Ponatinib has shown potent activity against chronic myeloid leukaemia that is resistant to available treatment, although it is associated with arterial occlusion. We investigated whether this activity and safety profile would result in superior outcomes compared with imatinib in previously untreated patients with chronic myeloid leukaemia. The Evaluation of Ponatinib versus Imatinib in Chronic Myeloid Leukemia (EPIC) study was a randomised, open-label, phase 3 trial designed to assess the efficacy and safety of ponatinib, compared with imatinib, in newly diagnosed patients with chronic-phase chronic myeloid leukaemia. Patients from 106 centres in 21 countries were randomly assigned (1:1, with stratification by Sokal score at diagnosis) using an interactive voice and web response system to receive oral ponatinib (45 mg) or imatinib (400 mg) once daily until progression, unacceptable toxicity, or other criteria for withdrawal were met. Eligible patients were at least 18 years of age, within 6 months of diagnosis, and Philadelphia chromosome-positive by cytogenetic assessment, with Eastern Cooperative Oncology Group performance status of 0-2, and had not previously been treated with tyrosine kinase inhibitors. The primary endpoint was major molecular response at 12 months. Patients who remained on study and had molecular assessments at specified timepoints were studied at those timepoints. Safety analyses included all treated patients, as per study protocol. This trial is registered with ClinicalTrials.gov, number NCT01650805. Between Aug 14, 2012, and Oct 9, 2013, 307 patients were randomly assigned to receive ponatinib (n=155) or imatinib (n=152). The trial was terminated early, on Oct 17, 2013, following concerns about vascular adverse events observed in patients given ponatinib in other trials. Trial termination limited assessment of the primary endpoint of major molecular response at 12 months, as only 13 patients in the imatinib group and ten patients in the

  8. Curvature-driven acceleration: a utopia or a reality?

    International Nuclear Information System (INIS)

    Das, Sudipta; Banerjee, Narayan; Dadhich, Naresh

    2006-01-01

    The present work shows that a combination of nonlinear contributions from the Ricci curvature in Einstein field equations can drive a late time acceleration of expansion of the universe. The transit from the decelerated to the accelerated phase of expansion takes place smoothly without having to resort to a study of asymptotic behaviour. This result emphasizes the need for thorough and critical examination of models with nonlinear contribution from the curvature

  9. Curvature-driven acceleration: a utopia or a reality?

    Energy Technology Data Exchange (ETDEWEB)

    Das, Sudipta [Relativity and Cosmology Research Centre, Department of Physics, Jadavpur University, Calcutta-700 032 (India); Banerjee, Narayan [Relativity and Cosmology Research Centre, Department of Physics, Jadavpur University, Calcutta-700 032 (India); Dadhich, Naresh [Inter University Centre for Astronomy and Astrophysics, Post Bag 4, Ganeshkhind, Pune 411 007 (India)

    2006-06-21

    The present work shows that a combination of nonlinear contributions from the Ricci curvature in Einstein field equations can drive a late time acceleration of expansion of the universe. The transit from the decelerated to the accelerated phase of expansion takes place smoothly without having to resort to a study of asymptotic behaviour. This result emphasizes the need for thorough and critical examination of models with nonlinear contribution from the curvature.

  10. Photonic Crystal Laser-Driven Accelerator Structures

    International Nuclear Information System (INIS)

    Cowan, Benjamin M.

    2007-01-01

    Laser-driven acceleration holds great promise for significantly improving accelerating gradient. However, scaling the conventional process of structure-based acceleration in vacuum down to optical wavelengths requires a substantially different kind of structure. We require an optical waveguide that (1) is constructed out of dielectric materials, (2) has transverse size on the order of a wavelength, and (3) supports a mode with speed-of-light phase velocity in vacuum. Photonic crystals---structures whose electromagnetic properties are spatially periodic---can meet these requirements. We discuss simulated photonic crystal accelerator structures and describe their properties. We begin with a class of two-dimensional structures which serves to illustrate the design considerations and trade-offs involved. We then present a three-dimensional structure, and describe its performance in terms of accelerating gradient and efficiency. We discuss particle beam dynamics in this structure, demonstrating a method for keeping a beam confined to the waveguide. We also discuss material and fabrication considerations. Since accelerating gradient is limited by optical damage to the structure, the damage threshold of the dielectric is a critical parameter. We experimentally measure the damage threshold of silicon for picosecond pulses in the infrared, and determine that our structure is capable of sustaining an accelerating gradient of 300 MV/m at 1550 nm. Finally, we discuss possibilities for manufacturing these structures using common microfabrication techniques

  11. Functional Data Analysis of Spaceflight-Induced Changes in Coordination and Phase in Head Pitch Acceleration During Treadmill Walking

    Science.gov (United States)

    Miller, Christopher; Peters, Brian; Feiveson, Alan; Bloomberg, Jacob

    2011-01-01

    Astronauts returning from spaceflight experience neurovestibular disturbances during head movements and attempt to mitigate them by limiting head motion. Analyses to date of the head movements made during walking have concentrated on amplitude and variability measures extracted from ensemble averages of individual gait cycles. Phase shifts within each gait cycle can be determined by functional data analysis through the computation of time-warping functions. Large, localized variations in the timing of peaks in head kinematics may indicate changes in coordination. The purpose of this study was to determine timing changes in head pitch acceleration of astronauts during treadmill walking before and after flight. Six astronauts (5M/1F; age = 43.5+/-6.4yr) participated in the study. Subjects walked at 1.8 m/sec (4 mph) on a motorized treadmill while reading optotypes displayed on a computer screen 4 m in front of their eyes. Three-dimensional motion of the subject s head was recorded with an Inertial Measurement Unit (IMU) device. Data were recorded twice before flight and four times after landing. The head pitch acceleration was calculated by taking the time derivative of the pitch velocity data from the IMU. Data for each session with each subject were time-normalized into gait cycles, then registered to align significant features and create a mean curve. The mean curves of each postflight session for each subject were re-registered based on their preflight mean curve to create time-warping functions. The root mean squares (RMS) of these warping functions were calculated to assess the deviation of head pitch acceleration mean curves in each postflight session from the preflight mean curve. After landing, most crewmembers exhibited localized shifts within their head pitch acceleration regimes, with the greatest deviations in RMS occurring on landing day or 1 day after landing. These results show that the alteration of head pitch coordination due to spaceflight may be

  12. The tandem betatron accelerator

    International Nuclear Information System (INIS)

    Keinigs, R.

    1991-01-01

    This paper reports that the tandem betatron is a compact, high-current induction accelerator that has the capability to accelerate electrons to an energy of order one gigavolt. Based upon the operating principle of a conventional betatron, the tandem betatron employs two synchronized induction cores operating 180 degrees out of phase. Embedded within the cores are the vacuum chambers, and these are connected by linear transport sections to allow for moving the beam back and forth between the two betatrons. The 180 degree phase shift between the core fluxes permits the circumvention of the flux swing constraint that limits the maximum energy gain of a conventional betatron. By transporting the beam between the synchronized cores, an electron can access more than one acceleration cycle, and thereby continue to gain energy. This added degree of freedom also permits a significant decrease in the size of the magnet system. Biasing coils provide independent control of the confining magnetic field. Provided that efficient beam switching can be performed, it appears feasible that a one gigavolt electron beam can be generated and confined. At this energy, a high current electron beam circulating in a one meter radius orbit could provide a very intense source of short wavelength (λ < 10 nm) synchrotron radiation. This has direct application to the emerging field of x-ray lithography. At more modest energies (10 MeV-30 MEV) a compact tandem betatron could be employed in the fields of medical radiation therapy, industrial radiography, and materials processing

  13. ETIOLOGICAL FACTORS OF CHRONIC GASTRITIS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    G.V. Volynets

    2006-01-01

    Full Text Available In the article the data on the study of the etiological factors of various types of chronic gastritis in children are presented. Based on revealing of the auto antibodies to parietal gastric cells in 40,0% of children autoimmune gastritis (a type gastritis is diagnosed. Helicobacterr pylori infection is revealed in 44,8% of children. In 27,6% of children type c gastritis is diagnosed. Autoimmune gastritis in children has been linked to the active phase of chronic epsteinbbarr virus infection. the etiological factors of nonautoimmune gastritis are Helicobacter pylori infection (type b gastritis and multiple duodenogastric refluxes (type c gastritis.Key words: children, chronic gastritis, etiological factors, autoimmune gastritis, nonautoimmune gastritis, active phase of chronic Epstein-Barr virus infection, Helicobacter pylori infection.

  14. Developing MESA : an accelerated reliability test

    NARCIS (Netherlands)

    Baskoro, G.; Rouvroye, J.L.; Bacher, W.; Brombacher, A.C.

    2003-01-01

    This paper describes the on-going research on an accelerated reliability test strategy called MESA (Multiple Environment Stress Analysis) intended to find in a fast and efficient manner (potential) reliability problems during the design phase of high volume consumer products. This test has shown

  15. Impact of wave phase jumps on stochastic heating

    International Nuclear Information System (INIS)

    Zasenko, V.I.; Zagorodny, A.G.; Cherniak, O.M.

    2016-01-01

    Interaction of charged particles with fields of random waves brings about known effects of stochastic acceleration and heating. Jumps of wave phases can increase the intensity of these processes substantially. Numerical simulation of particle heating and acceleration by waves with regular phases, waves with jumping phase and stochastic electric field impulses is performed. Comparison of the results shows that to some extent an impact of phase jumps is similar to the action of separate field impulses. Jumps of phase not only increase the intensity of resonant particle heating but involves in this process non-resonant particles from a wide range of initial velocities

  16. Оptimization of periodontitis treatment in patients with chronic brucellosis infection

    Directory of Open Access Journals (Sweden)

    L.A. Soboleva

    2010-06-01

    Full Text Available For the purpose to determine the clinical pathogenetic efficacy of Cycloferon liniment in the combined therapy of parodontitis in patients with chronic brucellosis medical examination and treatment of 50 patients was carried out. It was established that use of liniment Cycloferon in the combined treatment of patients with pariodontitis against chronic brucellosis allowed to accelerate process of normalization of parameters of lipid peroxidation and antioxidant potential of blood, to decrease infection load (herpes symplex virus I, candida albicans, staphylococcus aureus in parodontal recess and evidence of local inflammation with reduction of activity of tumour necrosis and interleukin 1b, that provided acceleration of recovery processes, lowering in frequency of pariodontitis recurrences

  17. Treatments for chronic myeloid leukemia: a qualitative systematic review

    Directory of Open Access Journals (Sweden)

    Ferdin

    2012-08-01

    Full Text Available Roxanne Ferdinand,1 Stephen A Mitchell,2 Sarah Batson,2 Indra Tumur11Pfizer, Tadworth, UK; 2Abacus International, Bicester, UKBackground: Chronic myeloid leukemia (CML is a myeloproliferative disorder of blood stem cells. The tyrosine kinase inhibitor (TKI imatinib was the first targeted therapy licensed for patients with chronic-phase CML, and its introduction was associated with substantial improvements in response and survival compared with previous therapies. Clinical trial data are now available for the second-generation TKIs (nilotinib, dasatinib, and bosutinib in the first-, second-, and third-line settings. A qualitative systematic review was conducted to qualitatively compare the clinical effectiveness, safety, and effect on quality of life of TKIs for the management of chronic-, accelerated-, or blast-phase CML patients.Methods: Included studies were identified through a search of electronic databases in September 2011, relevant conference proceedings and the grey literature.Results: In the first-line setting, the long-term efficacy (up to 8 years of imatinib has been confirmed in a single randomized controlled trial (International Randomized Study of Interferon [IRIS]. All second-generation TKIs reported lower rates of transformation, and comparable or superior complete cytogenetic response (CCyR, major molecular response (MMR, and complete molecular response rates compared with imatinib by 2-year follow-up. Each of the second-generation TKIs was associated with a distinct adverse-event profile. Bosutinib was the only second-generation TKI to report quality-of-life data (no significant difference compared with imatinib treatment. Data in the second- and third-line setting confirmed the efficacy of the second-generation TKIs in either imatinib-resistant or -intolerant patients, as measured by CCyR and MMR rates.Conclusion: Data from first-line randomized controlled trials reporting up to 2-year follow-up indicate superior response

  18. Gait strategy changes with acceleration to accommodate the biomechanical constraint on push-off propulsion.

    Science.gov (United States)

    Oh, Keonyoung; Baek, Juhyun; Park, Sukyung

    2012-11-15

    To maintain steady and level walking, push-off propulsion during the double support phase compensates for the energy loss through heel strike collisions in an energetically optimal manner. However, a large portion of daily gait activities also contains transient gait responses, such as acceleration or deceleration, during which the observed dominance of the push-off work or the energy optimality may not hold. In this study, we examined whether the push-off propulsion during the double support phase served as a major energy source for gait acceleration, and we also studied the energetic optimality of accelerated gait using a simple bipedal walking model. Seven healthy young subjects participated in the over-ground walking experiments. The subjects walked at four different constant gait speeds ranging from a self-selected speed to a maximum gait speed, and then they accelerated their gait from zero to the maximum gait speed using a self-selected acceleration ratio. We measured the ground reaction force (GRF) of three consecutive steps and the corresponding leg configuration using force platforms and an optical marker system, respectively, and we compared the mechanical work performed by the GRF during each single and double support phase. In contrast to the model prediction of an increase in the push-off propulsion that is proportional to the acceleration and minimizes the mechanical energy cost, the push-off propulsion was slightly increased, and a significant increase in the mechanical work during the single support phase was observed. The results suggest that gait acceleration occurs while accommodating a feasible push-off propulsion constraint. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Phase angle as a nutritional evaluation tool in all stages of chronic liver disease.

    Science.gov (United States)

    Peres, W A F; Lento, D F; Baluz, K; Ramalho, A

    2012-01-01

    Malnutrition is commonly and frequently under-diagnosed in clinical settings in patients with chronic liver disease (CLD) due to the limitations of nutritional evaluation methods in this population. We hypothesized that the bioelectrical impedance analysis derived phase angle (BIA-derived PhA) might be considered as a nutritional indicator in CLD since it represents either cell death or malnutrition characterized by changes in cellular membrane integrity. The aim of this study was to evaluate the BIA-derived PhA as a nutritional evaluation tool in all stages of CLD, including chronic hepatitis, liver cirrhosis and hepatocellular carcinoma (HCC). Liver-related death and survival were evaluated. A total of 66 patients were enrolled in a cross-sectional study. For the nutritional diagnosis, mid-arm circumference (MAC), triceps skinfold thickness (TST), mid-arm muscle circumference (MAMC) and Subject Global Assessment (SGA) were evaluated. Biochemical and clinical evaluations were performed. Our results showed that PhA was higher in well-nourished patients, according to SGA and in the patients without hepatic encephalopathy. PhA correlated significantly with MAMC, MAC and albumin and was inversely correlated with age. No correlation was found between PhA values and the Child-Pugh score and ascites. PhA was strongly associated with survival and PhA ≤ 5.18º with relative risk increase of 2.5 for death. We conclude that the BIA-derived PhA is a relevant nutritional evaluation tool in chronic hepatitis, liver cirrhosis and HCC and the role of PhA in the prediction of survival in CLD should be examined further in a controlled study.

  20. LONG-TERM RESULTS OF TARGET THERAPY WITH FIRST AND * SECOND-LINE TYROSINE KINASE INHIBITORS IN PATIENTS WITH CHRONIC MYELOID LEUKEMIA

    Directory of Open Access Journals (Sweden)

    L. L. Vysotskaya

    2015-01-01

    Full Text Available Aim: To assess long-term efficacy of firstand second-line tyrosine kinase inhibitors in non-selected patients with chronic myeloid leukemia in a real-life clinical setting.Materials and methods: The assessment is based on long-term results of a prospective single center comparative clinical trial that was based on non-selected groups of 116 patients with various stages of chronic myeloid leukemia being treated with a first generation tyrosine kinase inhibitor imatinib, and of 44 patients being treated with a second generation tyrosine kinase inhibitor nilotinib. We analyzed all-cause mortality, progression-free survival from April 2005 to April 2013, with a median of the follow-up of 128 months.Results: In 116 patients with chronic myeloid leukemia treated with imatinib, the Kaplan-Meier survival estimate was 120 months. In 44 patients at an early chronic phase, 5-year overall survival and progression-free survival was 93.2% and 8-year overall and progression-free survival was 79.5%. In 44 patients at a late chronic stage, 5-year overall and progression-free survival was 95.5%, 8-year overall and progression-free survival, 72.7%. In 28 patients at acceleration phase, 5-years overall survival was 78.6% and 8-year overall survival, 46%. Median of overall survival in patients treated with nilotinib was not reached. During 78.6 months of combination treatment with cytotoxic agents, tyrosine kinase inhibitors of the first (imatinib and second line (nilotinib, overall survival was 100%.Conclusion: In clinical practice, inclusion of patients with chronic myeloid leukemia and imatinib resistance (disease relapse or imatinib intolerance into the treatment program with frontline therapy with general cytotoxic agents and thereafter with firstand second-line tyrosine kinase inhibitors significantly improves overall survival.

  1. Study on radial-phase motion of a beam in the 3 cm electron linear accelerator

    International Nuclear Information System (INIS)

    Polyakov, V.A.; Shchedrin, I.S.

    1982-01-01

    Longitudinal and transverse dynamics of particles in a 3 cm electron linear accelerator (ELA) are. considered. Electron motion in the source and in the section before inlet onto the accelerating section, effect of the wave type input transformer as well as the effect of deviations of parameters of ELA supply system on oUtput characteristics of the beam have been taken into account. The results obtained permitted to explain a comparatively small value of accelerated current at the output of the LAEU-31M (38 m A). Recommendations on improvement of beam passogein the accelerating section are developed based on computerized calculations

  2. Now entering phase two...

    CERN Multimedia

    Katarina Anthony

    2012-01-01

    Building on the success of their feasibility phase, the CLIC test facility, CTF3, has just launched into a five-year project development phase. This will involve detailed performance optimisation studies, marking the project’s transition from pure research and development to prototyping and construction.   CLIC accelerator modules under construction at CERN. “With the feasibility phase now complete, we have established that CLIC can be built,” says Roberto Corsini, CLIC Collaboration spokesperson. “Now we want to be sure that it can provide the luminosity and energy performance needed. We will be looking at the engineering, performance and cost of a real CLIC machine also seeing if we can reduce it.” CTF3’s second phase will focus on selected performance-related research areas for further investigation. The largest of these involves the construction and testing of several authentic CLIC accelerator modules that are currently being ...

  3. Acceleration processes in the magnetospheric plasma: a review

    Energy Technology Data Exchange (ETDEWEB)

    Nishida, A [Tokyo Univ. (Japan). Inst. of Space and Aeronautical Science

    1975-01-01

    Our present knowledge on the acceleration process in the magnetospheric plasma is reviewed and major problems are summarized. Acceleration processes can be classified into three categories. First, acceleration can be made by the reconnection process in the magnetotail. The occurrence of reconnection during substorm expansion phases has been confirmed, but details of the energy conversion mechanism need be clarified. Second, acceleration by the electric potential drop along magnetic field lines has been strongly suggested from observations of precipitating particles. The position and structure of the potential layer, however, have not been clarified, and theoretical understanding of the process is still in the early stage of development. Third, particles can be adiabatically heated as they are driven toward the earth in the course of their convective motion. Spatial structure and dynamical development of the auroral precipitation pattern represent both challenge and clue to the understanding of the magnetospheric acceleration process.

  4. Effects of Sled Towing on Peak Force, the Rate of Force Development and Sprint Performance During the Acceleration Phase

    Directory of Open Access Journals (Sweden)

    Martínez-Valencia María Asunción

    2015-06-01

    Full Text Available Resisted sprint training is believed to increase strength specific to sprinting. Therefore, the knowledge of force output in these tasks is essential. The aim of this study was to analyze the effect of sled towing (10%, 15% and 20% of body mass (Bm on sprint performance and force production during the acceleration phase. Twenty-three young experienced sprinters (17 men and 6 women; men = 17.9 ± 3.3 years, 1.79 ± 0.06 m and 69.4 ± 6.1 kg; women = 17.2 ± 1.7 years, 1.65 ± 0.04 m and 56.6 ± 2.3 kg performed four 30 m sprints from a crouch start. Sprint times in 20 and 30 m sprint, peak force (Fpeak, a peak rate of force development (RFDpeak and time to RFD (TRFD in first step were recorded. Repeated-measures ANOVA showed significant increases (p ≤ 0.001 in sprint times (20 and 30 m sprint for each resisted condition as compared to the unloaded condition. The RFDpeak increased significantly when a load increased (3129.4 ± 894.6 N·s−1, p ≤ 0.05 and 3892.4 ± 1377.9 N·s−1, p ≤ 0.01. Otherwise, no significant increases were found in Fpeak and TRFD. The RFD determines the force that can be generated in the early phase of muscle contraction, and it has been considered a factor that influences performance of force-velocity tasks. The use of a load up to 20% Bm might provide a training stimulus in young sprinters to improve the RFDpeak during the sprint start, and thus, early acceleration.

  5. Report of the accelerator and beam line options working group

    International Nuclear Information System (INIS)

    Ankenbrandt, C.; Bogacz, A.; Bogert, D.; Bossert, R.C.; Brown, B.; Childress, S.; Crawford, C.; Dugan, G.; Even, L.; Finley, D.; Gelfand, N.; Gerig, R.; Goderre, G.; Gourlay, S.; Griffin, J.; Hahn, A.; Holmes, S.; Jackson, G.; Johnson, R.; Johnson, D.; Kerby, J.; Koepke, K.; Koizumi, G.; Koul, R.; Lamm, M.; MacLachlan, J.; Malamud, E.; Malensek, A.; Mantsch, P.; Marriner, J.; Marsh, B.; Martin, P.; Hills, F.; Moore, C.; Murphy, T.; Nicol, T.; Peterson, T.; Pruss, S.; Rameika, G.; Riddiford, A.; Rosenzweig, J.; Russell, A.; Saritepe, S.; Stahl, S.; Strait, J.; Trbojevic, D.; Visnjic, V.; Volk, J.; Johnson, D.; Syphers, M.; Mohl, D.; Ruggiero, S.; Collins, T.

    1990-01-01

    This report summarizes work done before, during, and after the conference. The group was broken down into six subgroups. Subgroup 1 considered collider aspects of the phase 1 and phase 2 upgrade plans. Also considered were the collider aspects of a specific example of Phase 3, namely the replacement of the Tevatron with a new ring providing 1.8 TeV per beam. Subgroup 2 considered specific improvements to the proposed Main Injector (MI) which will enhance the performance of Phase 2. Also considered were improvements which may be made to the present Main Ring (MR) which will enchance performance of Phase 1. Subgroup 3 considered fixed target aspects of the Phase 1 and 2 upgrade plans and a specific example of Phase 3, namely the replacement of the Tevatron with a new ring providing 1.5 TeV fixed target operation. Subgroup 4 considered the external beam lines associated with the upgrades. Subgroup 5 considered the new designs of the superconducting magnets and associated large cryogenic systems connected with the accelerator systems proposed by the other groups. Subgroup 6 assumed the existence of Phase 1 and 2 upgrades and considered new possibilities for Phase 3 such as new accelerators in new tunnels

  6. Vortex Formation and Acceleration of a Fish-Inspired Robot Performing Starts from Rest

    Science.gov (United States)

    Devoria, Adam; Bapst, Jonathan; Ringuette, Matthew

    2009-11-01

    We investigate the unsteady flow of a fish-inspired robot executing starts from rest, with the objective of understanding the connection among the kinematics, vortex formation, and acceleration performance. Several fish perform ``fast starts,'' where the body bends into a ``C'' or ``S'' shape while turning (phase I), followed by a straightening of the body and caudal fin and a linear acceleration (phase II). The resulting highly 3-D, unsteady vortex formation and its relationship to the acceleration are not well understood. The self-propelled robotic model contains motor-driven joints with programmable motion to emulate phase II of a simplified C-start. The experiments are conducted in a water tank, and the model is constrained to 1 direction along rails. The velocity is measured using digital particle image velocimetry (DPIV) in multiple planes. Vortex boundaries are identified using the finite-time Lyapunov exponent, then the unsteady vortex circulation is computed. The thrust is estimated from the identified vortices, and correlated with the circulation and model acceleration for different kinematics.

  7. The transmission theory of electrostatic analyzer in six dimensional phase space and the concept design of a supersensitive mass spectrometer beam line for HI-13 tandem accelerator

    International Nuclear Information System (INIS)

    Guan Xialing; Cao Qingxi; Zhang Jie; Ye Jingping

    1986-01-01

    It follows from the motion equations of charged particle in curvilinear coordinates system that the transfer matrix of electrostatic analyzer was derived in six dimensional phase space. In accordance with these matrixes, the concept design of the supersensitive mass spectrometer beam line for HI-13 tandem accelerator was calculated

  8. The grating as an accelerating structure

    International Nuclear Information System (INIS)

    Fernow, R.C.

    1991-02-01

    This report considers the use of a diffraction grating as an accelerating structure for charged particle beams. We examine the functional dependence of the electromagnetic fields above the surface of a grating. Calculations are made of the strength of the accelerating modes for structures with π and 2π phase advance per period and for incident waves polarized with either the E or H vector along the grooves of the grating. We consider examples of using gratings in a laser linac and in a grating lens. We also briefly examine previous results published about this subject. 36 refs

  9. Efficacy of romiplostim in patients with chronic immune thrombocytopenic purpura : a double-blind randomised controlled trial

    NARCIS (Netherlands)

    Kuter, David J.; Bussel, James B.; Lyons, Roger M.; Pullarkat, Vinod; Gernsheimer, Terry B.; Senecal, Francis M.; Aledort, Louis M.; George, James N.; Kessler, Craig M.; Sanz, Miguel A.; Liebman, Howard A.; Slovick, Frank T.; de Wolf, J. Th M.; Bourgeois, Emmanuelle; Guthrie, Troy H.; Newland, Adrian; Wasser, Jeffrey S.; Hamburg, Solomon I.; Grande, Carlos; Lefrere, Francois; Lichtin, Alan Eli; Tarantino, Michael D.; Terebelo, Howard R.; Viallard, Jean-Francois; Cuevas, Francis J.; Go, Ronald S.; Henry, David H.; Redner, Robert L.; Rice, Lawrence; Schipperus, Martin R.; Guo, D. Matthew; Nichol, Janet L.

    2008-01-01

    Background Chronic immune thrombocytopenic purpura (ITP) is characterised by accelerated platelet destruction and decreased platelet production. Short-term administration of the thrombopoiesis-stimulating protein, romiplostim, has been shown to increase platelet counts in most patients with chronic

  10. Effect of hypovolemia, infusion, and oral rehydration on gradual onset +Gz acceleration tolerance

    Science.gov (United States)

    Greenleaf, J. E.; Brock, P. J.; Haines, R. F.; Rositano, S. A.; Montgomery, L. D.; Keil, L. C.

    1976-01-01

    The purpose of this study was to determine the effect of blood withdrawal, blood infusion, and oral fluid intake on +Gz tolerance at an acceleration rate of 0.5 G/min. Six healthy men aged 21-27 yr were centrifuged after the withdrawal of 400 ml of blood (hypovolemia) from each man; they were centrifuged again following blood infusion (Phase I). Three weeks later the men were accelerated after similar hypovolemia and again after consuming 800 ml of an isotonic NaCl drink (Phase II). Phase I hypovolemia resulted in a reduction in tolerance in all subjects from a mean control level of 6.42 + or - 0.35 min to 5.45 + or - 0.17 min (-15.1%, p less than 0.05). Both infusion and drinking returned tolerances to control levels. During acceleration there were significant (p less than 0.05) increases in plasma vasopressin levels to 35 pg/ml; these were not influenced appreciably by infusion or drinking. In all acceleration runs there was an obligatory shift (loss) of plasma volume and electrolytes, especially potassium, regardless of the experimental treatments. Oral rehydration is shown to be as effective as blood replacement in restoring +Gz acceleration tolerance decrements due to hypovolemia.

  11. IFMIF accelerators design

    International Nuclear Information System (INIS)

    Mosnier, A.; Ratzinger, U.

    2008-01-01

    The IFMIF requirement for 250 mA current of deuteron beams at a nominal energy of 40 MeV is met by means of two identical continuous wave (CW) 175 MHz linear accelerators running in parallel, each delivering a 125 mA, 40 MeV deuteron beam to the common target. This approach allows to stay within the current capability of present RF linac technology while providing operational redundancy in case of failure of one of the linacs. Each linac comprises a sequence of acceleration and beam transport/matching stages. The ion source generates a 140 mA deuteron beam at 100 keV. A low energy beam transport (LEBT) transfers the deuteron beam from the source to a radio frequency quadrupole (RFQ) cavity. The RFQ bunches and accelerates the 125 mA beam to 5 MeV. The RFQ output beam is injected through a matching section into a drift-tube-linac (DTL) where it is accelerated to the final energy of 40 MeV. In the reference design, the final acceleration stage is a conventional Alvarez-type DTL with post-couplers operating at room temperature. Operation of both the RFQ and the DTL at the same relatively low frequency is essential for accelerating the high current deuteron beam with low beam loss. The primary concern of the IFMIF linacs is the minimization of beam losses, which could limit their availability and maintainability due to excessive activation of the linac and irradiation of the environment. A careful beam dynamics design is therefore needed from the source to the target to avoid the formation of particle halo that could finally be lost in the linac or transfer lines. A superconducting solution for the high energy portion of the linac using, for example, CH-structure or coaxial-type resonators, could offer some advantages, in particular the reduction of operational costs. Careful beam dynamics simulations and comparison tests with beam during the EVEDA phase are however necessary in order to fully assess the technical feasibility of such alternative solutions

  12. Phase measurement and control of bunched beams

    International Nuclear Information System (INIS)

    Lewis, R.N.

    1978-01-01

    An ion bean buncher was developed at ANL for bunching all ion species through a tandem accelerator. Transit time variations through the tandem, caused by ripple and fluctuations in the injection and lens power supplies and terminal voltage, and to varying voltage distributions in the accelerating tube, cause a beam-phase variation at the output of the tandem. A beam-phase measurement and control system was designed and installed in conjunction with the ion beam buncher to control beam phase at the tandem output. That system is described

  13. Quantifying factors determining the rate of CTL escape and reversion during acute and chronic phases of HIV infection

    Energy Technology Data Exchange (ETDEWEB)

    Ganusov, Vitaly V [Los Alamos National Laboratory; Korber, Bette M [Los Alamos National Laboratory; Perelson, Alan S [Los Alamos National Laboratory

    2009-01-01

    Human immunodeficiency virus (HIV) often evades cytotoxic T cell (CTL) responses by generating variants that are not recognized by CTLs. However, the importance and quantitative details of CTL escape in humans are poorly understood. In part, this is because most studies looking at escape of HIV from CTL responses are cross-sectional and are limited to early or chronic phases of the infection. We use a novel technique of single genome amplification (SGA) to identify longitudinal changes in the transmitted/founder virus from the establishment of infection to the viral set point at 1 year after the infection. We find that HIV escapes from virus-specific CTL responses as early as 30-50 days since the infection, and the rates of viral escapes during acute phase of the infection are much higher than was estimated in previous studies. However, even though with time virus acquires additional escape mutations, these late mutations accumulate at a slower rate. A poor correlation between the rate of CTL escape in a particular epitope and the magnitude of the epitope-specific CTL response suggests that the lower rate of late escapes is unlikely due to a low efficacy of the HIV-specific CTL responses in the chronic phase of the infection. Instead, our results suggest that late and slow escapes are likely to arise because of high fitness cost to the viral replication associated with such CTL escapes. Targeting epitopes in which virus escapes slowly or does not escape at all by CTL responses may, therefore, be a promising direction for the development of T cell based HIV vaccines.

  14. Heart Rate and Oxygen Saturation Change Patterns During 6-min Walk Test in Subjects With Chronic Thromboembolic Pulmonary Hypertension.

    Science.gov (United States)

    Inagaki, Takeshi; Terada, Jiro; Yahaba, Misuzu; Kawata, Naoko; Jujo, Takayuki; Nagashima, Kengo; Sakao, Seiichiro; Tanabe, Nobuhiro; Tatsumi, Koichiro

    2017-12-26

    The 6-min walk test (6MWT) is commonly performed to assess functional status in patients with chronic thromboembolic pulmonary hypertension. However, changes in heart rate and oxygen saturation ( S pO 2 ) patterns during 6MWT in patients with chronic thromboembolic pulmonary hypertension remain unclear. Thirty-one subjects with chronic thromboembolic pulmonary hypertension were retrospectively evaluated to examine the relationships between the change in heart rate (Δheart rate), heart rate acceleration time, slope of heart rate acceleration, heart rate recovery during the first minute after 6MWT (HRR1), change in S pO 2 (Δ S pO 2 ), S pO 2 reduction time, and S pO 2 recovery time during 6MWT, and the severity of pulmonary hemodynamics assessed by right heart catheterization and echocardiography. Subjects with severe chronic thromboembolic pulmonary hypertension had significantly longer heart rate acceleration time (144.9 ± 63.9 s vs 96.0 ± 42.5 s, P = .033), lower Δheart rate (47.4 ± 16.9 vs 61.8 ± 13.6 beats, P = .02), and lower HRR1 (13.3 ± 9.0 beats vs 27.1 ± 9.2 beats, P pulmonary hypertension. Subjects with severe chronic thromboembolic pulmonary hypertension also had significantly longer S pO 2 reduction time (178.3 ± 70.3 s vs 134.3 ± 58.4 s, P = .03) and S pO 2 recovery time (107.6 ± 35.3 s vs 69.8 ± 32.7 s, P = .004) than did subjects with mild chronic thromboembolic pulmonary hypertension. Multivariate linear regression analysis showed only mean pulmonary arterial pressure independently was associated with heart rate acceleration time and slope of heart rate acceleration. Heart rate and S pO 2 change patterns during 6MWT is predominantly associated with pulmonary hemodynamics in subjects with chronic thromboembolic pulmonary hypertension. Evaluating heart rate and S pO 2 change patterns during 6MWT may serve a safe and convenient way to follow the change in pulmonary hemodynamics. Copyright © 2017 by Daedalus Enterprises.

  15. Development of the accelerating system

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jiho; Kwon, H. J.; Kim, D. I.; Kim, H. S.; Ryu, J. Y.; Park, B. S.; Seol, K. T.; Yun, S. P.; Song, Y. G.; Cho, Y. S.

    2013-02-15

    One of the main purposes of the 'Development of the Accelerating System' is developing a 100-MeV proton linac which accelerate proton beams from 20 MeV to 100 MeV by using 7 DTL (drift tube linac) tanks. Two of them were finished in the 2-nd stage of the project. The remaining part was also successfully fabricated and installed at Gyeongju site of KAERI. The MEBT is an essential component to extract and supply 20-MeV proton beams to users, and to match proton beams to the next accelerating structure for 100-MeV acceleration. The development of the MEBT has successfully finished. The project also developed the digital LLRF (low level RF) system which control the accelerating field within 1% in magnitude and 1 degree in phase. This system has been successfully tested in the 20-MeV linac operation at Daejeon site of KAERI. The modified version of the digital LLRF system will be used in the 100-MeV linac operation. The project also developed the beam diagnostic system. They are the strip-line type beam position monitor (BPM), the beam current monitor (CT), the beam loss monitor (BLM), and the emittance measurement system. They are used to measure the characteristics of the 20-MeV proton beams. The project also developed the EPIC-based control system. It is used to monitor the status of the accelerator and components, and to remotely control accelerator components. It has been used and modified in the 20-MeV linac operation. The modified version of the LLRF, diagnostics and control systems will be used in 100-MeV linac operation.

  16. Mast cell leukemia associated with undefined morphology and chronic basophilic leukemia.

    Science.gov (United States)

    Cehreli, Cavit; Alacacioglu, Inci; Piskin, Ozden; Ates, Halil; Cehreli, Ruksan; Calibasi, Gizem; Yuksel, Erdinc; Ozkal, Sermin; Ozsan, Guner H

    2014-01-01

    Mast cell leukemia (MCL) is rare type of neoplasia with an incidence of 1% in a large series of 342 adult patients with systemic mastocytosis (SM). Chronic basophilic leukemia (CBL) is an extremely rare type of leukemia with appearance of 7 cases in the literature. A 73 year-old female patient who presented with weaknes, had a prolonged duration of hematologic remission after treatment of her CBL by hydroxyurea (HU). Evolution of SM occurring as a second neoplasia concurrently with relapse of de novo CBL was demonstrated by mast cells (MCs) infiltration in the bone marrow (BM) biopsy and smear and increase in tryptase level. Transformation to MCL with simultaneous occurrance of accelerated phase of CBL were documented by the appearance of MCs in both BM and peripheral blood (PB) smears, antigen expressions detected by flow cytometry and spesific stains. Sequence analysis of c-kit gene revealed c-kit exon 11 K550N mutation. Undefined associations of MCL with different mast cell morphology, increase in IL-6 level and accelerated phase of de novo CBL was described. Elevations in CRP and IL-6 levels occurring with increases in basophil counts to high levels revealed that febrile episodes with abdominal pain seen in our patient were induced by increase in IL-6 levels released from neoplastic basophils. Neoplastic basophils with diffuse and coarse basophilic granules possibly mimic neutrophils with toxic granules and cause wrong characterization of neoplastic basophils as neutrophils by the automated blood cell counters and misleaded physicians.

  17. Weekly bi-fractionated 40 Gy three-dimensional conformational accelerated partial irradiation of breast: results of a phase II French pilot study

    International Nuclear Information System (INIS)

    Bourgier, C.; Pichenot, C.; Verstraet, R.; Heymann, S.; Biron, B.; Delaloge, S.; Garbay, J.R.; Marsiglia, H.; Bourhis, J.; Taghian, A.; Marsiglia, H.

    2010-01-01

    The authors report the first French experience of three-dimensional conformational and accelerated partial irradiation of breast. Twenty five patients have been concerned by this phase II trial. The prescribed total dose was 40 Gy, was delivered over 5 days in two daily fractions. Irradiation was performed with two 6 MV tangential mini-beams and a 6-22 MeV front electron beams. The planning target volume coverage was very good. Toxicity has been assessed. Healthy tissues (heart, lungs) are considerably protected. The acute and late toxicity is correct. Short communication

  18. Study and realization of an electron linear accelerator. Dynamics of accelerated electrons

    International Nuclear Information System (INIS)

    Bernard, J.

    1966-12-01

    The theoretical characteristics of the electron linear accelerator are: 30 MeV for the energy W S and 250 mA for the peak current I c . The main utilization is the intense production of fast neutrons by the reactions (γ,n) and (γ,f) induced in a target of natural uranium by the accelerated electrons. In the first part of the thesis, relative to the study and the realization of the accelerator, a new equation of dispersion is established analytically when the guide is loaded with round-edged irises. The relation is compared with the equation established by CHU and Hansen, WALKINSHAW, KVASIL in the case of a guide loaded with flat-edged irises. The experimental and theoretical curves of dispersion are compared. The accuracy of every relation of dispersion is estimated. The second part of the thesis is relative to the theoretical study of the electrons dynamics in the guide; it allows the derivation of the parameters of the beam: dispersion of phase, energy, dispersion of energy and the relation W S = f (I c ). The results relative to the first experiments are given and compared with the theoretical expectations. (author) [fr

  19. Trapping and dark current in plasma-based accelerators

    International Nuclear Information System (INIS)

    Schroder, C.B.; Esarey, E.; Shadwick, B.A.; Leemans, W.P.

    2004-01-01

    The trapping of thermal electrons in a nonlinear plasma wave of arbitrary phase velocity is investigated. The threshold plasma wave amplitude for trapping plasma electrons is calculated, thereby determining the fraction trapped and the expected dark current in a plasma-based accelerator. It is shown that the presence of a laser field (e.g., trapping in the self-modulated regime of the laser wakefield accelerator) increases the trapping threshold. Implications for experimental and numerical laser-plasma studies are discussed

  20. Transfer of accelerated presbycusis by transplantation of bone marrow cells from senescence-accelerated mice.

    Science.gov (United States)

    Baba, Susumu; Iwai, Hiroshi; Inaba, Muneo; Kawamoto, Kohei; Omae, Mariko; Yamashita, Toshio; Ikehara, Susumu

    2006-11-20

    Until now, there has been no effective therapy for chronic sensorineural hearing impairment. This study investigated the role of bone marrow cells (BMCs) in cochlear dysfunction. BALB/c mice (2 months of age), a non-presbycusis-prone mouse strain, were lethally irradiated and then transplanted with BMCs from SAMP1 mice (2 months of age), a presbycusis-prone mouse strain. Acceleration of age-related hearing loss, early degeneration of spiral ganglion cells (SGCs) and impairment of immune function were observed in the recipient mice as well as in the SAMP1 mice. However, no spiral ganglion cells of donor (SAMP1) origin were detected in the recipient mice. These results indicated that accelerated presbycusis, cochlear pathology, and immune dysfunction of SAMP1 mice can be transferred to BALB/c recipient mice using allogeneic bone marrow transplantation (BMT). However, although the BMCs themselves cannot differentiate into the spiral ganglion cells (SGCs), they indirectly cause the degeneration of the SGCs. Further studies into the relationship between the inner ear cells and BMCs are required.

  1. Laser wakefield accelerator based light sources: potential applications and requirements

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). NIF and Photon Sciences; Thomas, A. G. [Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Nuclear Engineering and Radiological Sciences; Mangles, S. P.D. [Imperial College, London (United Kingdom). Blackett Lab.; Banerjee, S. [Univ. of Nebraska, Lincoln, NE (United States); Corde, S. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Flacco, A. [ENSTA, CNRS, Ecole Polytechnique, Palaiseau (France); Litos, M. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Neely, D. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Viera, J. [Univ. of Lisbon (Portugal). GoLP-Inst. de Plasmas e Fusao Nuclear-Lab. Associado; Najmudin, Z. [Imperial College, London (United Kingdom). Blackett Lab.; Bingham, R. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Joshi, C. [Univ. of California, Los Angeles, CA (United States). Dept. of Electrical Engineering; Katsouleas, T. [Duke Univ., Durham, NC (United States). Platt School of Engineering

    2015-01-15

    In this article we review the prospects of laser wakefield accelerators as next generation light sources for applications. This work arose as a result of discussions held at the 2013 Laser Plasma Accelerators Workshop. X-ray phase contrast imaging, X-ray absorption spectroscopy, and nuclear resonance fluorescence are highlighted as potential applications for laser-plasma based light sources. We discuss ongoing and future efforts to improve the properties of radiation from plasma betatron emission and Compton scattering using laser wakefield accelerators for these specific applications.

  2. Developments on the RF system for the Fusion Materials Irradiation Test Facility accelerator

    International Nuclear Information System (INIS)

    Fazio, M.V.; Johnson, H.P.; Riggin, D.M.

    1979-01-01

    The rf system for the Fusion Materials Irradiation Test (FMIT) accelerator is currently in the design phase at the Los Alamos Scientific Laboratory (LASL). The 35-MeV, 100-mA deuteron beam will require approximately 6 MW of rf power at 80 MHz. The EIMAC 8973 power tetrode, capable of a 600-kW cw output, has been chosen as the final amplifier tube for each of 15 amplifier chains. The final power stage of each chain is designed to perform as a linear Class B amplifier. Each low-power rf system (less than or equal to 100W) is to be phase, amplitude, and frequency controlled to provide a drive signal for each high-power amplifier. Beam dynamics for particle acceleration and for minimal beam spill require each rf amplifier output to be phase controlled to +-1 0 . The amplitude of the accelerating field must be held to +-1%. A varactor-tuned electronic phase shifter and a linear phase detector are under development for use in this system. To complement hardware development, analog computer simulations are being performed to optimize the closed-loop control characteristics of the system

  3. Beam loading effects in a standing wave accelerator structure

    International Nuclear Information System (INIS)

    Arai, Shigeaki; Katayama, Takeshi; Tojyo, Eiki; Yoshida, Katsuhide.

    1978-11-01

    The steady-state beam loading effects on the accelerating field in the disk-loaded structure of a standing wave type have been systematically studied. The electron bunch from a 15 MeV electron linac is injected at arbitrary phase of the external driving field in the test structure. The change of the phase shift of the accelerating field and that of the stored energy are measured as a function of the phase on which the bunch rides. The former shows drastic change when the bunch is around the crest of the driving field and when the beam loading is heavy, whereas the latter varies sinusoidally for any beam loading. The resonant frequency shift of the structure due to beam loading is estimated by using the measured results. All the experimental results are well explained by the normal mode analysis of the microwave cavity theory. (author)

  4. Association between regular molecular monitoring and tyrosine kinase inhibitor therapy adherence in chronic myelogenous leukemia in the chronic phase.

    Science.gov (United States)

    Guérin, Annie; Chen, Lei; Dea, Katherine; Wu, Eric Q; Goldberg, Stuart L

    2014-07-01

    Adherence with oral tyrosine kinase inhibitor (TKI) therapy over prolonged timeframes is required for successful outcomes among patients with chronic phase chronic myelogenous leukemia (CP-CML). Since quantitative polymerase chain reaction (qPCR) monitoring may identify early suboptimal responses, and thereby permit detection of non-adherence to therapy, we sought to assess the association between frequency of molecular monitoring and medication adherence. This is a retrospective cohort study design of diagnosed CP-CML obtained from two large US administrative claims databases. Patients were grouped into cohorts based on the number of qPCR tests they had. Adherence was assessed both by medication possession ratio (MPR) and proportion of days covered (PDC) and was compared between qPCR cohorts. A sensitivity analysis was performed by adjusting for the number of oncology outpatient visits not due to routine molecular monitoring. Over the 12 month study period, 1205 CML patients met the selection criteria; 41.0% had no qPCR tests, 31.9% had 1-2 tests, and 27.1% had 3-4 tests; 88.9% of patients were initiated on imatinib. Patients in the 3-4 qPCR tests cohort had an average MPR that was 10.22 (p sensitivity analysis were consistent with core analysis findings, excluding number of physician visits as a potential driver of adherence. These findings demonstrate an association, not causation, between molecular monitoring frequency and adherence. Frequent molecular monitoring (3-4 times per year as recommended in current guidelines) is associated with greater TKI treatment adherence for patients diagnosed with CML. Since TKI adherence >80% has been associated with better clinical outcomes, this study underscores the importance of molecular monitoring.

  5. [Vitamins and microelements in patients with chronic kidney disease].

    Science.gov (United States)

    Małgorzewicz, Sylwia; Jankowska, Magdalena; Kaczkan, Małgorzata; Czajka, Beata; Rutkowski, Bolesław

    2014-01-01

    The supply of vitamins and microelements in patients with chronic kidney disease (CKD) is very important and requires special attention. CKD patients presented deficiency of these substances in the diet and in organism, but also excess of fat-soluble vitamins or trace elements is observed. Studies indicate that deficiency of vitamins and antioxidants in diet and also enhanced oxidative stress are cause of many complications for example: accelerated process of arteriosclerosis in patients with chronic kidney disease.

  6. Low power RF measurements of travelling wave type linear accelerator

    International Nuclear Information System (INIS)

    Reddy, Sivananda; Wanmode, Yashwant; Bhisikar, A.; Shrivastava, Purushottam

    2015-01-01

    RRCAT is engaged in the development of travelling wave (TW) type linear accelerator for irradiation of industrial and agricultural products. TW accelerator designed for 2π/3 mode to operate at frequency of 2856 MHz. It consists of input coupler, buncher cells, regular cells and output coupler. Low power measurement of this structure includes measurement of resonant frequency of the cells for different resonant modes and quality factor, tuning of input-output coupler and measurement of phase advance per cell and electric field in the structure. Steele's non-resonant perturbation technique has been used for measurement of phase advance per cell and electric field in the structure. Kyhl's method has been used for the tuning of input-output coupler. Computer based automated bead pull set-up has been developed for measurement of phase advance per cell and electric field profile in the structure. All the codes are written in Python for interfacing of Vector Network Analyzer (VNA) , stepper motor with computer. These codes also automate the measurement process. This paper describes the test set- up for measurement and results of measurement of travelling wave type linear accelerating structure. (author)

  7. KEK/JAERI joint project on high intensity proton accelerators

    International Nuclear Information System (INIS)

    Nagamiya, Shoji

    2002-01-01

    From JFY01, which started on April 1, 2001, a new accelerator project to provide high-intensity proton beams proceeded into a construction phase. This project is conducted under a cooperation of two institutions, KEK and JAERI. The accelerator complex will provide 1 MW proton beams at 3 GeV and 0.75 MW beams at 50 GeV. The project will be completed within six years. In this article I will describe a) the project itself, b) sciences to be pursued at this new accelerator complex and c) the present status and future plans of the project. (author)

  8. KEK/JAERI Joint Project on high-intensity proton accelerators

    International Nuclear Information System (INIS)

    Nagamiya, Shoji

    2003-01-01

    From JFY01, which started on April 1, 2001, a new accelerator project to provide high-intensity proton beams proceeded into a construction phase. This project is conducted under a cooperation of two institutions, KEK and JAERI. The accelerator complex will provide 1 MW proton beams at 3 GeV and 0.75 MW beams at 50 GeV. The project will be completed within 6 years. In this article I will describe (a) the project itself, (b) sciences to be pursued at this new accelerator complex and (c) the present status and future plans of the project

  9. Simultaneous regression of Philadelphia chromosome and multiple nonrecurrent clonal chromosomal abnormalities with imatinib mesylate in a patient autografted 22 years before for chronic myelogenous leukemia.

    Science.gov (United States)

    Van Den Akker, J; Coppo, P; Portnoï, M F; Barbu, V; Bories, D; Gorin, N C

    2007-09-01

    A 31-year-old patient developed chronic myelogenous leukemia (CML) in November, 1983. In November 1984, following a diagnosis of acceleration, he received an autologous hemopoietic transplant after conditioning with cyclophosphamide and total body irradiation. The autologous marrow was purged with mafosfamide. Over 20 years, the patient remained in chronic phase of CML. Multiple nonrecurrent clonal chromosomal abnormalities appeared leading to a very complex karyotype, including among others involvement of chromosomes 1, 7, 9, 13, 19, and X. Fluorescent in situ hybridization showed that the two chromosomes 9 were involved. Acute myeloid crisis was diagnosed in February, 2004. Treatment with imatinib mesylate resulted within 6 months in a total disappearance of all chromosomal abnormalities with a complete cytogenetic and molecular response, which persists 3 years later. We question whether the ex vivo purging procedure with mafosfamide has favored the occurrence of these particular cytogenetic abnormalities (with no independent oncogenic potential) within the original leukemic stem cell pool. It remains unclear whether the autologous transplantation has indeed resulted into some prolongation of the duration of the chronic phase, which lasted for 20 years. At time of acute crisis, the dramatic response to imatinib mesylate leading to a complete cytogenetic and molecular response is noteworthy.

  10. The theory of accelerated particles in AVF cyclotrons

    International Nuclear Information System (INIS)

    Schulte, W.M.

    1978-01-01

    This thesis deals with the study of the motion of accelerated charged particles in an AVF cyclotron. This study has been done on behalf of the VICKSI- project of the Hahn-Meitner-Institut in West Berlin. A new theory is developed which facilitates an accurate description of the influence of the acceleration on the motion in the median plane of a cyclotron. The theory is applied to systems with 1 or 2 Dee electrodes, the frequency of the accelerating voltage being equal to the revolution frequency of the particles or a higher harmonic of this frequency. It turned out that the betatron oscillations in the radial phase space may be disturbed considerably as a result of the acceleration. In the theory the author makes use of the Hamilton formalism. After a number of canonical transformations a Hamilton function was found, in which the most important effects show themselves clearly. The corresponding equations of motion can be solved very quickly with the help of a simple computer program. The results of this theory are in agreement with those of extensive numerical orbit integration programmes. In this thesis attention is also devoted to the centering of the beam in the VICKSI cyclotron just after injection, the possibility to obtain single-turn extraction and the interpretation of the high frequency phase measurements. (Auth.)

  11. Aggregation of MBP in chronic demyelination.

    Science.gov (United States)

    Frid, Kati; Einstein, Ofira; Friedman-Levi, Yael; Binyamin, Orli; Ben-Hur, Tamir; Gabizon, Ruth

    2015-07-01

    Misfolding of key disease proteins to an insoluble state is associated with most neurodegenerative conditions, such as prion, Parkinson, and Alzheimer's diseases. In this work, and by studying animal models of multiple sclerosis, we asked whether this is also the case for myelin basic protein (MBP) in the late and neurodegenerative phases of demyelinating diseases. To this effect, we tested whether MBP, an essential myelin component, present prion-like properties in animal models of MS, as is the case for Cuprizone-induced chronic demyelination or chronic phases of Experimental Autoimmune Encephalomyelitis (EAE). We show here that while total levels of MBP were not reduced following extensive demyelination, part of these molecules accumulated thereafter as aggregates inside oligodendrocytes or around neuronal cells. In chronic EAE, MBP precipitated concomitantly with Tau, a marker of diverse neurodegenerative conditions, including MS. Most important, analysis of fractions from Triton X-100 floatation gradients suggest that the lipid composition of brain membranes in chronic EAE differs significantly from that of naïve mice, an effect which may relate to oxidative insults and subsequently prevent the appropriate insertion and compaction of new MBP in the myelin sheath, thereby causing its misfolding and aggregation. Prion-like aggregation of MBP following chronic demyelination may result from an aberrant lipid composition accompanying this pathological status. Such aggregation of MBP may contribute to neuronal damage that occurs in the progressive phase of MS.

  12. Microwave measurements of azimuthal asymmetries in accelerating fields of disk-loaded waveguides

    International Nuclear Information System (INIS)

    Loew, G.A.; Deruyter, H.; Defa, W.

    1983-03-01

    This paper presents microwave measurements of azimuthal asymmetries in the accelerating fields of the SLAC disk-loaded waveguide. These field asymmetries lead to rf phase-dependent beam steering which can be detrimental to operation of linear accelerators in general and of the SLAC Linear Collider in particular

  13. Microwave measurements of azimuthal asymmetries in accelerating fields of disk-loaded waveguides

    International Nuclear Information System (INIS)

    Loew, G.A.; Defa, Wang; Deruyter, H.

    1983-01-01

    This paper presents microwave measurements of azymuthal asymmetries in the accelerating fields of the SLAC disk-loaded waveguide. These field asymmetries lead to RF phase-dependent beam steering which can be detrimental to operation of linear accelerators in general and of the SLAC Linear Collider in particular

  14. X-ray diagnosis of bronchial obstruction in chronic pneumonia

    International Nuclear Information System (INIS)

    Mamilyaev, R.M.

    1981-01-01

    Combined radiobronchological examination of patients with chronic pneumonia in the phase of reverse development of the disease has been performed. Severity, localization and extent of bronchial obstruction have been studied, depending on the phase of chronic pneumonia and aspects of lung tissue alterations. Bronchial lesions characteristic of chronic pneumonia were defined, as well as importance of x-ray examination methods for bronchial obstruction diagnosis. Three types of bronchial obstruction were distinguished: bronchoconstriction, bronchodilatation and their combination. With regard to the character and severity of bronchial and pulmonary tissue lesions 3 variants of chronic pneumonia are offered to be differentiated: bronchitic, bronchoectatic, and abscess-forming. The main significance in diagnosis of chronic pneumonia is attributed to combined x-ray examination, which also includes radiobronchological investigation in the first two variants of the disease [ru

  15. A reflexing electron microwave amplifier for rf particle accelerator applications

    International Nuclear Information System (INIS)

    Fazio, M.V.; Hoeberling, R.F.

    1988-01-01

    The evolution of rf-accelerator technology toward high-power, high-current, low-emittance beams produces an ever-increasing demand for efficient, very high power microwave power sources. The present klystron technology has performed very well but is not expected to produce reliable gigawatt peak-power units in the 1- to 10-GHz regime. Further major advancements must involve other types of sources. The reflexing-electron class of sources can produce microwave powers at the gigawatt level and has demonstrated operation from 800-MHz to 40-GHz. The pulse length appears to be limited by diode closure, and reflexing-electron devices have been operated in a repetitively pulsed mode. A design is presented for a reflexing electron microwave amplifier that is frequency and phase locked. In this design, the generated microwave power can be efficiently coupled to one or several accelerator loads. Frequency and phase-locking capability may permit parallel-source operation for higher power. The low-frequency (500-MHz to 10-GHz) operation at very high power required by present and proposed microwave particle accelerators makes an amplifier, based on reflexing electron phenomena, a candidate for the development of new accelerator power sources. (author)

  16. Direct observation of the phase space footprint of a painting injection in the Rapid Cycling Synchrotron at the Japan Proton Accelerator Research Complex

    Directory of Open Access Journals (Sweden)

    P. K. Saha

    2009-04-01

    Full Text Available The 3 GeV Rapid Cycling Synchrotron (RCS at Japan Proton Accelerator Research Complex is nearly at the operational stage with regard to the beam commissioning aspects. Recently, the design painting injection study has been commenced with the aim of high output beam power at the extraction. In order to observe the phase space footprint of the painting injection, a method was developed utilizing a beam position monitor (BPM in the so-called single pass mode. The turn-by-turn phase space coordinates of the circulating beam directly measured using a pair of BPMs entirely positioned in drift space, and the calculated transfer matrices from the injection point to the pair of BPMs with several successive turns were used together in order to obtain the phase space footprint of the painting injection. There are two such pairs of BPMs placed in two different locations in the RCS, the results from which both agreed and were quite consistent with what was expected.

  17. Direct observation of the phase space footprint of a painting injection in the Rapid Cycling Synchrotron at the Japan Proton Accelerator Research Complex

    Science.gov (United States)

    Saha, P. K.; Shobuda, Y.; Hotchi, H.; Hayashi, N.; Takayanagi, T.; Harada, H.; Irie, Y.

    2009-04-01

    The 3 GeV Rapid Cycling Synchrotron (RCS) at Japan Proton Accelerator Research Complex is nearly at the operational stage with regard to the beam commissioning aspects. Recently, the design painting injection study has been commenced with the aim of high output beam power at the extraction. In order to observe the phase space footprint of the painting injection, a method was developed utilizing a beam position monitor (BPM) in the so-called single pass mode. The turn-by-turn phase space coordinates of the circulating beam directly measured using a pair of BPMs entirely positioned in drift space, and the calculated transfer matrices from the injection point to the pair of BPMs with several successive turns were used together in order to obtain the phase space footprint of the painting injection. There are two such pairs of BPMs placed in two different locations in the RCS, the results from which both agreed and were quite consistent with what was expected.

  18. Overview of Phase Space Manipulations of Relativistic Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, Dao; /SLAC

    2012-08-31

    Phase space manipulation is a process to rearrange beam's distribution in 6-D phase space. In this paper, we give an overview of the techniques for tailoring beam distribution in 2D, 4D, and 6D phase space to meet the requirements of various applications. These techniques become a new focus of accelerator physics R&D and very likely these advanced concepts will open up new opportunities in advanced accelerators and the science enabled by them.

  19. Overview of Phase Space Manipulations of Relativistic Electron Beams

    International Nuclear Information System (INIS)

    Xiang, Dao

    2012-01-01

    Phase space manipulation is a process to rearrange beam's distribution in 6-D phase space. In this paper, we give an overview of the techniques for tailoring beam distribution in 2D, 4D, and 6D phase space to meet the requirements of various applications. These techniques become a new focus of accelerator physics R and D and very likely these advanced concepts will open up new opportunities in advanced accelerators and the science enabled by them.

  20. COAXIAL TWO-CHANNEL DIELECTRIC WAKE FIELD ACCELERATOR

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L. [Omega-P, Inc.

    2013-04-30

    Theory, computations, and experimental apparatus are presented that describe and are intended to confirm novel properties of a coaxial two-channel dielectric wake field accelerator. In this configuration, an annular drive beam in the outer coaxial channel excites multimode wakefields which, in the inner channel, can accelerate a test beam to an energy much higher than the energy of the drive beam. This high transformer ratio is the result of judicious choice of the dielectric structure parameters, and of the phase separation between drive bunches and test bunches. A structure with cm-scale wakefields has been build for tests at the Argonne Wakefield Accelerator Laboratory, and a structure with mm-scale wakefields has been built for tests at the SLAC FACET facility. Both tests await scheduling by the respective facilities.

  1. Accelerator research studies. Progress report

    International Nuclear Information System (INIS)

    1983-07-01

    The major goal of this project is to study the effects that lead to emittance growth and limitation of beam current and brightness in periodic focusing systems (including linear accelerators). This problem is of great importance for all accelerator applications requiring high intensity beams with small emittance such as heavy ion fusion, spallation neutron sources and high energy physics. In the latter case, future machines must not only provide higher energies (in the range of 10 to 100 TeV), but also higher luminosities than the existing facilities. This implies considerably higher phase-space density of the particle beam produced by the injector linac, i.e., the detrimental emittance growth and concurrent beam loss observed in existing linacs must be avoided

  2. Silymarin Accelerates Liver Regeneration after Partial Hepatectomy

    Directory of Open Access Journals (Sweden)

    Jia-Ping Wu

    2015-01-01

    Full Text Available Partial hepatectomy (PHx is a liver regeneration physiological response induced to maintain homeostasis. Liver regeneration evolved presumably to protect wild animals from catastrophic liver loss caused by toxins or tissue injury. Silymarin (Sm ability to stimulate liver regeneration has been an object of curiosity for many years. Silymarin has been investigated for use as an antioxidant and anticarcinogen. However, its use as a supportive treatment for liver damage is elusive. In this study, we fed silymarin (Sm, 25 mg/kg to male Sprague-Dawley rats for 7 weeks. Surgical 2/3 PHx was then conducted on the rats at 6 hrs, 24 hrs, and 72 hrs. Western blot and RT-PCR were conducted to detect the cell cycle activities and silymarin effects on hepatic regeneration. The results showed that silymarin enhanced liver regeneration by accelerating the cell cycle in PHx liver. Silymarin led to increased G1 phase (cyclin D1/pRb, S phase (cyclin E/E2F, G2 phase (cyclin B, and M phase (cyclin A protein and mRNA at 6 hrs, 24 hrs, and 72 hrs PHx. HGF, TGFα, and TGFβ1 growth factor expressions were also enhanced. We suggest that silymarin plays a crucial role in accelerated liver regeneration after PHx.

  3. Alternating phase focussing including space charge

    International Nuclear Information System (INIS)

    Cheng, W.H.; Gluckstern, R.L.

    1992-01-01

    Longitudinal stability can be obtained in a non-relativistic drift tube accelerator by traversing each gap as the rf accelerating field rises. However, the rising accelerating field leads to a transverse defocusing force which is usually overcome by magnetic focussing inside the drift tubes. The radio frequency quadrupole is one way of providing simultaneous longitudinal and transverse focusing without the use of magnets. One can also avoid the use of magnets by traversing alternate gaps between drift tubes as the field is rising and falling, thus providing an alternation of focussing and defocusing forces in both the longitudinal and transverse directions. The stable longitudinal phase space area is quite small, but recent efforts suggest that alternating phase focussing (APF) may permit low velocity acceleration of currents in the 100-300 ma range. This paper presents a study of the parameter space and a test of crude analytic predictions by adapting the code PARMILA, which includes space charge, to APF. 6 refs., 3 figs

  4. Computer simulation of dynamic processes on accelerators

    International Nuclear Information System (INIS)

    Kol'ga, V.V.

    1979-01-01

    The problems of computer numerical investigation of motion of accelerated particles in accelerators and storages, an effect of different accelerator systems on the motion, determination of optimal characteristics of accelerated charged particle beams are considered. Various simulation representations are discussed which describe the accelerated particle dynamics, such as the enlarged particle method, the representation where a great number of discrete particle is substituted for a field of continuously distributed space charge, the method based on determination of averaged beam characteristics. The procedure is described of numerical studies involving the basic problems, viz. calculation of closed orbits, establishment of stability regions, investigation of resonance propagation determination of the phase stability region, evaluation of the space charge effect the problem of beam extraction. It is shown that most of such problems are reduced to solution of the Cauchy problem using a computer. The ballistic method which is applied to solution of the boundary value problem of beam extraction is considered. It is shown that introduction into the equation under study of additional members with the small positive regularization parameter is a general idea of the methods for regularization of noncorrect problems [ru

  5. The CEBAF accelerator and its physics program

    International Nuclear Information System (INIS)

    Cardman, L.S.

    1993-01-01

    The continuous electron beam accelerator facility (CEBAF) consists of a pair of 400 MeV superconducting linacs together with a 5-pass recirculation system and beam switchyard that will permit it to provide three, simultaneous 4 GeV, cw electron beams with a total current of up to 200 μA. The conventional construction for the accelerator and the three experimental end stations is essentially complete. The first linac has been installed in the accelerator tunnel and beam has been accelerated through it; all tests to date have met or exceeded the design specifications. The major components of the experimental equipment for the end stations are under construction. Operation of CEBAF for nuclear physics is scheduled to begin in mid-1994. The facility will support a broad range of nuclear physics research, including topics such as how quarks and gluons are held together in protons and neutrons, the origins of the nuclear force, modifications of nucleons in the nuclear medium, and nuclear structure when nucleons are very close together. The status of the accelerator and its experimental equipment will be presented together with a sampling of experiments planned for the early phases of operation

  6. Ultra-relativistic ion acceleration in the laser-plasma interactions

    Energy Technology Data Exchange (ETDEWEB)

    Huang Yongsheng; Wang Naiyan; Tang Xiuzhang; Shi Yijin [China Institute of Atomic Energy, Beijing 102413 (China); Xueqing Yan [Institute of Heavy Ion Physics, Peking University, Beijing 100871 (China)

    2012-09-15

    An analytical relativistic model is proposed to describe the relativistic ion acceleration in the interaction of ultra-intense laser pulses with thin-foil plasmas. It is found that there is a critical value of the ion momentum to make sure that the ions are trapped by the light sail and accelerated in the radiation pressure acceleration (RPA) region. If the initial ion momentum is smaller than the critical value, that is in the classical case of RPA, the potential has a deep well and traps the ions to be accelerated, as the same described before by simulation results [Eliasson et al., New J. Phys. 11, 073006 (2009)]. There is a new ion acceleration region different from RPA, called ultra-relativistic acceleration, if the ion momentum exceeds the critical value. In this case, ions will experience a potential downhill. The dependence of the ion momentum and the self-similar variable at the ion front on the acceleration time has been obtained. In the ultra-relativistic limit, the ion momentum at the ion front is proportional to t{sup 4/5}, where t is the acceleration time. In our analytical hydrodynamical model, it is naturally predicted that the ion distribution from RPA is not monoenergetic, although the phase-stable acceleration mechanism is effective. The critical conditions of the laser and plasma parameters which identify the two acceleration modes have been achieved.

  7. Ultra-relativistic ion acceleration in the laser-plasma interactions

    International Nuclear Information System (INIS)

    Huang Yongsheng; Wang Naiyan; Tang Xiuzhang; Shi Yijin; Xueqing Yan

    2012-01-01

    An analytical relativistic model is proposed to describe the relativistic ion acceleration in the interaction of ultra-intense laser pulses with thin-foil plasmas. It is found that there is a critical value of the ion momentum to make sure that the ions are trapped by the light sail and accelerated in the radiation pressure acceleration (RPA) region. If the initial ion momentum is smaller than the critical value, that is in the classical case of RPA, the potential has a deep well and traps the ions to be accelerated, as the same described before by simulation results [Eliasson et al., New J. Phys. 11, 073006 (2009)]. There is a new ion acceleration region different from RPA, called ultra-relativistic acceleration, if the ion momentum exceeds the critical value. In this case, ions will experience a potential downhill. The dependence of the ion momentum and the self-similar variable at the ion front on the acceleration time has been obtained. In the ultra-relativistic limit, the ion momentum at the ion front is proportional to t 4/5 , where t is the acceleration time. In our analytical hydrodynamical model, it is naturally predicted that the ion distribution from RPA is not monoenergetic, although the phase-stable acceleration mechanism is effective. The critical conditions of the laser and plasma parameters which identify the two acceleration modes have been achieved.

  8. The peculiarities of particle dynamics in the Fermi acceleration scheme

    International Nuclear Information System (INIS)

    Buts, V.A.

    2015-01-01

    With examples of discrete and distributed mathematical models of the Fermi acceleration mechanism, a usefulness, or even necessity, of taking into account of singular solutions is demonstrated. Also the role is shown of those parts of phase space where the uniqueness theorem conditions to form the dynamics of physical systems are broken. It was found that the dynamics of particles in discrete and distributed mathematical schemes of Fermi acceleration can be significantly different. The difference is due to the fact that the distributed model takes into account the effects of phase space where conditions do not correspond to those necessary for application of the uniqueness theorem. The role of singular solutions is under discussion as well.

  9. Electron pulse shaping in the FELIX RF accelerator

    International Nuclear Information System (INIS)

    Weits, H.H.; Geer, C.A.J. van der; Oepts, D.; Meer, A.F.G. van der

    1999-01-01

    The FELIX free-electron laser uses short pulses of relativistic electrons produced by an RF accelerator. The design target for the duration of these electron bunches was around 3 ps. In experiments we observed that the bunches emit coherently enhanced spontaneous emission (CSE) when they travel through an undulator. It was demonstrated that the power level of the CSE critically depends on the settings of the accelerator. In this article we seek to explain these observations by studying the length and shape of the electron bunches as a function of the settings of the accelerator. A particle-tracking model was used to simulate the acceleration and transport processes. These include bunch compression in a 14-cell travelling wave buncher cavity, acceleration in a travelling wave linear accelerator, and passage through a (dispersive) chicane structure. The effect of the phase setting of the RF accelerating field with respect to the arrival time of the electron bunch in each accelerator structure was studied. The parameter range of the simulations is related to that of an actual free-electron laser experiment using these bunches. We find that, for specific settings of the accelerating system, electron pulses with a length of 350 μm FWHM (1 ps) are produced. The charge in the bunch rises steeply within a distance of 25 μm. This bunch shape explains the high level of coherently enhanced spontaneous emission observed in the FELIX laser. (author)

  10. LEP superconducting accelerating cavity module

    CERN Multimedia

    1995-01-01

    With its 27-kilometre circumference, the Large Electron-Positron (LEP) collider was the largest electron-positron accelerator ever built. The excavation of the LEP tunnel was Europe’s largest civil-engineering project prior to the Channel Tunnel. Three tunnel-boring machines started excavating the tunnel in February 1985 and the ring was completed three years later. In its first phase of operation, LEP consisted of 5176 magnets and 128 accelerating cavities. CERN’s accelerator complex provided the particles and four enormous detectors, ALEPH, DELPHI, L3 and OPAL, observed the collisions. LEP was commissioned in July 1989 and the first beam circulated in the collider on 14 July. The collider's initial energy was chosen to be around 91 GeV, so that Z bosons could be produced. The Z boson and its charged partner the W boson, both discovered at CERN in 1983, are responsible for the weak force, which drives the Sun, for example. Observing the creation and decay of the short-lived Z boson was a critical test of...

  11. Modulational effects in accelerators

    International Nuclear Information System (INIS)

    Satogata, T.

    1997-01-01

    We discuss effects of field modulations in accelerators, specifically those that can be used for operational beam diagnostics and beam halo control. In transverse beam dynamics, combined effects of nonlinear resonances and tune modulations influence diffusion rates with applied tune modulation has been demonstrated. In the longitudinal domain, applied RF phase and voltage modulations provide mechanisms for parasitic halo transport, useful in slow crystal extraction. Experimental experiences with transverse tune and RF modulations are also discussed

  12. High power testing of the multiple-loop radio-frequency drive concept for the FMIT accelerator

    International Nuclear Information System (INIS)

    Fazio, M.V.; Patton, R.D.

    1984-04-01

    The Fusion Materials Irradiation Test (FMIT) accelerator requires several 600-kW rf systems to simultaneously supply rf power to a single accelerator tank. Each rf-system output must be carefully phase and amplitude controlled to achieve the proper system performance. Two 80-MHz, 600-kW rf amplifiers with phase- and amplitude-control systems have been tested into a single, high-Q resonant cavity. Experimental results are presented

  13. CHARACTERISATION OF THE ALICE ACCELERATOR AS AN INJECTOR FOR THE EMMA NS-FFAG

    CERN Document Server

    Garland, J M; McKenzie, J W; Muratori, B D

    2010-01-01

    EMMA (ElectronModel with Many Applications) is the first proof-of-principle non-scaling FFAG accelerator and is presently under construction at Daresbury Laboratory in the UK. To probe different parts of the bunch phase space during the acceleration from 10 to 20 MeV (which requires rapid resonance crossing), electron bunches are needed with sufficiently small emittance. To understand the phase space painting into the 3000 mm-mrad EMMA acceptance, we have modelled ALICE (Accelerators and Lasers in Combined Experiments) - which acts as an injector for EMMA - using GPT and compared the estimated emittances with measurements made with a variety of screen-based methods. Although the emittances are not yet as small as desired, we obtain reasonable agreement between simulation and measurement.

  14. Lymphocytosis after treatment with dasatinib in chronic myeloid leukemia: Effects on response and toxicity.

    Science.gov (United States)

    Schiffer, Charles A; Cortes, Jorge E; Hochhaus, Andreas; Saglio, Giuseppe; le Coutre, Philipp; Porkka, Kimmo; Mustjoki, Satu; Mohamed, Hesham; Shah, Neil P

    2016-05-01

    The proliferation of clonal cytotoxic T-cells or natural killer cells has been observed after dasatinib treatment in small studies of patients with chronic myeloid leukemia (CML). The incidence of lymphocytosis and its association with response, survival, and side effects were assessed in patients from 3 large clinical trials. Overall, 1402 dasatinib-treated patients with newly diagnosed CML in chronic phase (CML-CP), CML-CP refractory/intolerant to imatinib, or with CML in accelerated or myeloid-blast phase were analyzed. Lymphocytosis developed in 32% to 35% of patients and persisted for >12 months. This was not observed in the patients who received treatment with imatinib. Dasatinib-treated patients in all stages of CML who developed lymphocytosis were more likely to achieve a complete cytogenetic response, and patients who had CML-CP with lymphocytosis were more likely to achieve major and deep molecular responses. Progression-free and overall survival rates were significantly longer in patients with CML-CP who were refractory to or intolerant of imatinib and had lymphocytosis. Pleural effusions developed more commonly in patients with lymphocytosis. Overall, lymphocytosis occurred and persisted in many dasatinib-treated patients in all phases of CML. Its presence was associated with higher response rates, significantly longer response durations, and increased overall survival, suggesting an immunomodulatory effect. Prospective studies are warranted to characterize the functional activity of these cells and to assess whether an immunologic effect against CML is detectable. Cancer 2016;122:1398-1407. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  15. Numerical investigation on the effects of acceleration reversal times in Rayleigh-Taylor Instability with multiple reversals

    Science.gov (United States)

    Farley, Zachary; Aslangil, Denis; Banerjee, Arindam; Lawrie, Andrew G. W.

    2017-11-01

    An implicit large eddy simulation (ILES) code, MOBILE, is used to explore the growth rate of the mixing layer width of the acceleration-driven Rayleigh-Taylor instability (RTI) under variable acceleration histories. The sets of computations performed consist of a series of accel-decel-accel (ADA) cases in addition to baseline constant acceleration and accel-decel (AD) cases. The ADA cases are a series of varied times for the second acceleration reversal (t2) and show drastic differences in the growth rates. Upon the deceleration phase, the kinetic energy of the flow is shifted into internal wavelike patterns. These waves are evidenced by the examined differences in growth rate in the second acceleration phase for the set of ADA cases. Here, we investigate global parameters that include mixing width, growth rates and the anisotropy tensor for the kinetic energy to better understand the behavior of the growth during the re-acceleration period. Authors acknowledge financial support from DOE-SSAA (DE-NA0003195) and NSF CAREER (#1453056) awards.

  16. Bone marrow transplantation for patients with chronic myeloid leukemia

    International Nuclear Information System (INIS)

    Goldman, J.M.; Apperley, J.F.; Jones, L.

    1986-01-01

    Between February 1981 and December 1984 we treated 52 patients with chronic myeloid leukemia in the chronic phase and 18 patients with more advanced disease by high-dose chemoradiotherapy followed by allogeneic bone marrow transplantation using marrow cells from HLA-identical sibling donors. In addition, the 40 patients who had not previously undergone splenectomy received radiotherapy to the spleen. To prevent graft versus host disease, cyclosporine was given either alone or in conjunction with donor marrow depleted of T cells. Of the 52 patients treated in the chronic phase, 38 are alive after a median follow-up of 25 months (range, 7 to 50); the actuarial survival at two years was 72%, and the actuarial risk of relapse was 7%. Of the 18 patients with more advanced disease, 4 have survived; the actuarial two-year survival was 18%, and the actuarial risk of relapse was 42%. We conclude that the probability of cure is highest if transplantation is performed while the patient remains in the chronic phase of chronic myeloid leukemia. T-cell depletion may have reduced the incidence and severity of graft versus host disease. The value of irradiation to the spleen before transplantation has not been established

  17. Accelerator design and construction in the 1950s

    International Nuclear Information System (INIS)

    Blewett, J.P.

    1989-01-01

    This article looks into the history of the design, construction and operation of four of the large particle accelerators of the 1950s, the Cosmotron and more powerful alternating-gradient synchrotron (AGS) at Brookhaven, the Bevatron at Berkeley and the CERN proton synchrotron in Geneva with which the author was involved. The author's own contribution was in magnet design for the Cosmotron and the radiofrequency accelerating system. He later worked on linear accelerators and strong focusing later used in the AGS with Nick Christofilos from Athens. Collaboration between CERN and Brookhaven continued following a British study of alternating-gradient focusing which showed up possible resonance problems. In 1953, the ''phase transition'' problem was overcome. The author's personal contribution to the AGS project completes the article. (UK)

  18. Optical signatures of discharges in parallel coupled DC accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Rajan, Rehim N.; Banerjee, Srutarshi; Acharya, S.N., E-mail: rehim@barc.gov.in [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India); and others

    2014-07-01

    Parallel coupled voltage multiplier based accelerator topologies offer advantages of better regulation and ripple compared to their series coupled counterparts for Industrial electron beam accelerators. During conditioning and operation these systems undergoes various types of electrical discharges. The discharge can be a direct spark over from the high voltage terminal to ground through SF{sub 6} insulation, vacuum breakdown in the accelerating tube maintained in the order of 10{sup -7} mbar pressure, or local discharge between corona guards which are used to couple RF power to the multiplier. There could be discharges in between dynodes of the accelerating tube. As the inter electrode discharges do not reflect in load current, detection of these conditions becomes very difficult. Optical discharge detection methods can be used effectively in this situation. Photo multiplier based optical discharge detection has been deployed in a 3 MeV DC accelerator. Characteristics of the optical signal received during conditioning phase have been presented in this paper. (author)

  19. Transmission electron microscope interfaced with ion accelerators and its application to materials science

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Hiroaki; Naramoto, Hiroshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Hojou, Kiichi; Furuno, Shigemi; Tsukamoto, Tetsuo

    1997-03-01

    We have developed the transmission/analytical electron microscope interfaced with two sets of ion accelerators (TEM-Accelerators Facility) at JAERI-Takasaki. The facility is expected to provide quantitative insights into radiation effects, such as damage evolution, irradiation-induced phase transformation and their stability, through in-situ observation and analysis under ion and/or electron irradiation. The TEM-Accelerators Facility and its application to materials research are reviewed. (author)

  20. Measurement of Electron Clouds in Large Accelerators by Microwave Dispersion

    Energy Technology Data Exchange (ETDEWEB)

    De Santis, S.; Byrd, J.M.; /LBL, Berkeley; Caspers, F.; /CERN; Krasnykh, A.; /SLAC; Kroyer, T.; /CERN; Pivi, M.T.F.; /SLAC; Sonnad, K.G.; /LBL, Berkeley

    2008-03-19

    Clouds of low energy electrons in the vacuum beam pipes of accelerators of positively charged particle beams present a serious limitation for operation at high currents. Furthermore, it is difficult to probe their density over substantial lengths of the beam pipe. We have developed a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave transmitted over a section of the accelerator and used it to measure the average electron cloud density over a 50 m section in the positron ring of the PEP-II collider at the Stanford Linear Accelerator Center.

  1. Laser acceleration in vacuum with an open iris-loaded waveguide

    International Nuclear Information System (INIS)

    Xie, Ming

    1997-05-01

    An open iris-loaded waveguide structure is considered for laser acceleration of highly relativistic particle in vacuum. Complete characterization of all eigenmodes are given in analytical form for the structure. In particular the dominant radially polarized TM mode is evaluated in detail for laser acceleration. The entire parameter space is searched and it is found that below the laser damage threshold of the structure an acceleration gradient around 1 GV/m can be obtained over a phase slippage length of 10s of cm with TWs laser in the wavelength range from 1 to 10 μm

  2. A large superconducting accelerator project. International linear collider (ILC). Introduction

    International Nuclear Information System (INIS)

    Yamamoto, Akira

    2013-01-01

    The international linear collider (ILC) is proposed as the next-energy-frontier particle accelerator anticipated to be realized through global cooperation. The ILC accelerator is composed of a pair of electron and positron linear accelerators to realize head-on collision with a center-of-mass energy of 500 (250+250) GeV. It is based on superconducting radio-frequency (SCRF) technology, and the R and D and technical design have progressed in the technical design phase since 2007, and the technical design report (TDR) reached completion in 2012. This report reviews the ILC general design and technology. (author)

  3. Accelerator mass spectrometry for radiocarbon dating

    International Nuclear Information System (INIS)

    Bronk, C.R.

    1987-01-01

    Accelerator mass spectrometry (AMS) has been used routinely for radiocarbon measurements for several years. This thesis describes theoretical work to understand the reasons for low accuracy and range and offers practical solutions. The production and transport of the ions used in the measurements are found to be the most crucial stages in the process. The theories behind ion production by sputtering are discussed and applied to the specific case of carbon sputtered by caesium. Experimental evidence is also examined in relation to the theories. The phenomena of space charge and lens aberrations are discussed along with the interaction between ion beams and gas molecules in the vacuum. Computer programs for calculating phase space transformations are then described; these are designed to help investigations of the effects of space charge and aberrations on AMS measurements. Calculations using these programs are discussed in relation both to measured ion beam profiles in phase space and to the current dependent transmission of ions through the Oxford radiocarbon accelerator. Improvements have been made to this accelerator and these are discussed in the context of the calculations. C - ions are produced directly from carbon dioxide at the Middleton High Intensity Sputter Source. Experiments to evaluate the performance of such a source are described and detailed design criteria established. An ion source designed and built specifically for radiocarbon measurements using carbon dioxide is described. Experiments to evaluate its performance and investigate the underlying physical processes are discussed. (author)

  4. The long-term clinical implications of clonal chromosomal abnormalities in newly diagnosed chronic phase chronic myeloid leukemia patients treated with imatinib mesylate.

    Science.gov (United States)

    Lee, Sung-Eun; Choi, Soo Young; Bang, Ju-Hee; Kim, Soo-Hyun; Jang, Eun-Jung; Byeun, Ji-Young; Park, Jin Eok; Jeon, Hye-Rim; Oh, Yun Jeong; Kim, Myungshin; Kim, Dong-Wook

    2012-11-01

    The aim of this study was to evaluate the long-term clinical significance of an additional chromosomal abnormality (ACA), variant Philadelphia chromosome (vPh) at diagnosis, and newly developed other chromosomal abnormalities (OCA) in patients with chronic myeloid leukemia (CML) on imatinib (IM) therapy. Sequential cytogenetic data from 281 consecutive new chronic phase CML patients were analyzed. With a median follow-up of 78.6 months, the 22 patients with vPh (P = 0.034) or ACA (P = 0.034) at diagnosis had more events of IM failure than did the patients with a standard Ph. The 5-year overall survival (OS), event-free survival (EFS), and failure-free survival (FFS) rates for patients with vPh at diagnosis were 77.8%, 75.0%, and 53.3%, respectively; for patients with ACA at diagnosis, 100%, 66.3%, and 52.1%, respectively; and for patients with a standard Ph, 96.0%, 91.3%, and 83.7%, respectively. During IM therapy, eight patients developed an OCA, which had no impact on outcomes as a time-dependent covariate in our Cox proportional hazards regression models. This study showed that vPh was associated with poor OS and FFS and that ACA had adverse effects on EFS and FFS. In addition, no OCA, except monosomy 7, had any prognostic impact, suggesting that the development of OCA may not require a change in treatment strategy. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Excitation of accelerating plasma waves by counter-propagating laser beams

    International Nuclear Information System (INIS)

    Shvets, Gennady; Fisch, Nathaniel J.; Pukhov, Alexander

    2002-01-01

    The conventional approach to exciting high phase velocity waves in plasmas is to employ a laser pulse moving in the direction of the desired particle acceleration. Photon downshifting then causes momentum transfer to the plasma and wave excitation. Novel approaches to plasma wake excitation, colliding-beam accelerator (CBA), which involve photon exchange between the long and short counter-propagating laser beams, are described. Depending on the frequency detuning Δω between beams and duration τ L of the short pulse, there are two approaches to CBA. First approach assumes (τ L ≅2/ω p ). Photons exchanged between the beams deposit their recoil momentum in the plasma driving the plasma wake. Frequency detuning between the beams determines the direction of the photon exchange, thereby controlling the phase of the plasma wake. This phase control can be used for reversing the slippage of the accelerated particles with respect to the wake. A variation on the same theme, super-beatwave accelerator, is also described. In the second approach, a short pulse with τ L >>ω p -1 detuned by Δω∼2ω p from the counter-propagating beam is employed. While parametric excitation of plasma waves by the electromagnetic beatwave at 2ω p of two co-propagating lasers was first predicted by Rosenbluth and Liu [M. N. Rosenbluth and C. S. Liu, Phys. Rev. Lett. 29, 701 (1972)], it is demonstrated that the two excitation beams can be counter-propagating. The advantages of using this geometry (higher instability growth rate, insensitivity to plasma inhomogeneity) are explained, and supporting numerical simulations presented

  6. Pyrexia-associated Relapse in Chronic Inflammatory Demyelinating Polyradiculoneuropathy: A Case Report.

    Science.gov (United States)

    Ueda, Jun; Yoshimura, Hajime; Kohara, Nobuo

    2018-04-27

    Chronic inflammatory demyelinating polyradiculoneuropathy is a relapsing-remitting or chronic progressive demyelinating polyradiculoneuropathy. We report the case of a patient with chronic inflammatory demyelinating polyradiculoneuropathy who experienced relapses on four occasions after experiencing pyrexia and flu-like symptoms. Our patient showed characteristic features, such as relapse after pyrexia and flu-like symptoms, remission after pyretolysis without treatment, and the absence of remarkable improvement in a nerve conduction study in the remission phase. The serum level of tumor necrosis factor-α was elevated in the relapse phase and reduced in the remission phase; thus, the induction of cytokine release by viral infection might have caused the relapses.

  7. Elementary principles of linear accelerators

    International Nuclear Information System (INIS)

    Loew, G.A.; Talman, R.

    1983-09-01

    These lectures come in five sections. The first is this introduction. The second is a short chronology of what are viewed as important milestones in the field. The third covers proton linacs. It introduces elementary concepts such as transit time, shunt impedance, and Q. Critical issues such as phase stability and transverse forces are discussed. The fourth section contains an elementary discussion of waveguide accelerating structures. It can be regarded as an introduction to some of the more advanced treatments of the subject. The final section is devoted to electron accelerators. Taking SLAC as an example, various topics are discussed such as structure design, choice of parameters, frequency optimization, beam current, emittance, bunch length and beam loading. Recent developments and future challenges are mentioned briefly. 41 figures, 4 tables

  8. Accelerator complex for unstable beams at INS

    International Nuclear Information System (INIS)

    Tomizawa, M.; Arai, S.; Doi, M.; Katayama, T.; Niki, K.; Tokuda, N.; Yoshizawa, M.

    1992-11-01

    The construction of the prototype facility of the Exotic arena in the Japan Hadron Project (JHP) is started in 1992 at the Institute for Nuclear Study (INS), University of Tokyo. The purpose of this facility is to study the various technical problems of the Exotic arena, and to perform the experiment on nuclear and astrophysics with unstable nuclear beam. The unstable nuclei produced by bombarding a thick target with 40 MeV proton beam from the existing SF cyclotron are ionized in the ion sources, mass-analyzed by an ISOL, and transported to the accelerator complex. The accelerator complex consists of a split coaxial RFQ and an interdigital H type linac. The construction of accelerator will be completed in fiscal year 1994. The development of the SCRFQ and the IH linac which is suitable to the post-accelerator of the SCRFQ are reported. Charge stripper and the beam matching between the SCRFQ and the IH linac are explained. A buncher is necessary for the matching of longitudinal phase space between the SCRFQ and the IH linac. (K.I.)

  9. Imatinib Intolerance Is Associated With Blastic Phase Development in Philadelphia Chromosome-Positive Chronic Myeloid Leukemia.

    Science.gov (United States)

    Ángeles-Velázquez, Jorge Luis; Hurtado-Monroy, Rafael; Vargas-Viveros, Pablo; Carrillo-Muñoz, Silvia; Candelaria-Hernández, Myrna

    2016-08-01

    Over the past years, the survival of patients with Philadelphia-positive chronic myeloid leukemia (CML Ph(+)) has increased as a result of therapy with tyrosin kinase inhibitors (TKIs). Intolerance to TKIs has been described in approximately 20% of patients receiving treatment. We studied the incidence of imatinib intolerance in patients with CML Ph(+) and their outcome in our CML reference site, as there is no information about the evolution of patients intolerant to TKIs. A group of 86 patients with CML Ph(+) receiving imatinib monotherapy who abandoned treatment were the basis for this study. We present the trends of their disease evolution. The median of age at diagnosis was 42 years. Within a year, 19 (22%) of 86 patients developed imatinib intolerance, all of them with grade III or IV disease that required imatinib dose reduction or discontinuation. Of these patients, 16 (84%) of 19 developed transformation to blastic phase. The cumulative incidences of blastic phase development were 47% in the nonintolerant group and 84% in the intolerant group. There was a relative risk for those with imatinib intolerance to develop blastic phase of 1.78 (95% confidence interval, 1.28 to 2.42) (P treatment is available. Future research should to determine whether the origin of this evolution is really due to the intolerance itself or whether it is due to a more aggressive form of the disease, perhaps related to genetic transformation. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. A new version of a free electron laser Two-Beam Accelerator

    International Nuclear Information System (INIS)

    Sessler, A.M.; Sternbach, E.; Wurtele, J.S.

    1988-09-01

    A new version of a Two-Beam Accelerator is proposed in which in each period of the drive structure a very small input microwave signal is amplified to a large power level and then completely removed and transferred to the accelerating structure. In this manner a number of difficulties with the original version are eliminated or greatly relieved; namely, rf phase and amplitude sensitivity, growth of sidebands, and rf manipulation (removal of the microwaves from the drive structure, and transmission of microwave power through the accelerating cavities). 11 refs., 6 figs., 2 tabs

  11. Dynamics of electron acceleration in laser-driven wakefields. Acceleration limits and asymmetric plasma waves

    Energy Technology Data Exchange (ETDEWEB)

    Popp, Antonia

    2011-12-16

    The experiments presented in this thesis study several aspects of electron acceleration in a laser-driven plasma wave. High-intensity lasers can efficiently drive a plasma wave that sustains electric fields on the order of 100 GV/m. Electrons that are trapped in this plasma wave can be accelerated to GeV-scale energies. As the accelerating fields in this scheme are 3-4 orders of magnitude higher than in conventional radio-frequency accelerators, the necessary acceleration distance can be reduced by the same factor, turning laser-wakefield acceleration (LWFA) into a promising compact, and potentially cheaper, alternative. However, laser-accelerated electron bunches have not yet reached the parameter standards of conventional accelerators. This work will help to gain better insight into the acceleration process and to optimize the electron bunch properties. The 25 fs, 1.8 J-pulses of the ATLAS laser at the Max-Planck-Institute of Quantum Optics were focused into a steady-state flow gas cell. This very reproducible and turbulence-free gas target allows for stable acceleration of electron bunches. Thus the sensitivity of electron parameters to subtle changes of the experimental setup could be determined with meaningful statistics. At optimized experimental parameters, electron bunches of {approx}50 pC total charge were accelerated to energies up to 450 MeV with a divergence of {approx}2 mrad FWHM. As, in a new design of the gas cell, its length can be varied from 2 to 14 mm, the electron bunch energy could be evaluated after different acceleration distances, at two different electron densities. From this evolution important acceleration parameters could be extracted. At an electron density of 6.43. 10{sup 18} cm{sup -3} the maximum electric field strength in the plasma wave was determined to be {approx}160 GV/m. The length after which the relativistic electrons outrun the accelerating phase of the electric field and are decelerated again, the so-called dephasing length

  12. Dynamics of electron acceleration in laser-driven wakefields. Acceleration limits and asymmetric plasma waves

    International Nuclear Information System (INIS)

    Popp, Antonia

    2011-01-01

    The experiments presented in this thesis study several aspects of electron acceleration in a laser-driven plasma wave. High-intensity lasers can efficiently drive a plasma wave that sustains electric fields on the order of 100 GV/m. Electrons that are trapped in this plasma wave can be accelerated to GeV-scale energies. As the accelerating fields in this scheme are 3-4 orders of magnitude higher than in conventional radio-frequency accelerators, the necessary acceleration distance can be reduced by the same factor, turning laser-wakefield acceleration (LWFA) into a promising compact, and potentially cheaper, alternative. However, laser-accelerated electron bunches have not yet reached the parameter standards of conventional accelerators. This work will help to gain better insight into the acceleration process and to optimize the electron bunch properties. The 25 fs, 1.8 J-pulses of the ATLAS laser at the Max-Planck-Institute of Quantum Optics were focused into a steady-state flow gas cell. This very reproducible and turbulence-free gas target allows for stable acceleration of electron bunches. Thus the sensitivity of electron parameters to subtle changes of the experimental setup could be determined with meaningful statistics. At optimized experimental parameters, electron bunches of ∼50 pC total charge were accelerated to energies up to 450 MeV with a divergence of ∼2 mrad FWHM. As, in a new design of the gas cell, its length can be varied from 2 to 14 mm, the electron bunch energy could be evaluated after different acceleration distances, at two different electron densities. From this evolution important acceleration parameters could be extracted. At an electron density of 6.43. 10 18 cm -3 the maximum electric field strength in the plasma wave was determined to be ∼160 GV/m. The length after which the relativistic electrons outrun the accelerating phase of the electric field and are decelerated again, the so-called dephasing length, was found to be 4.9 mm

  13. Mathematical model of accelerator output characteristics and their calculation on a computer

    International Nuclear Information System (INIS)

    Mishulina, O.A.; Ul'yanina, M.N.; Kornilova, T.V.

    1975-01-01

    A mathematical model is described of output characteristics of a linear accelerator. The model is a system of differential equations. Presence of phase limitations is a specific feature of setting the problem which makes it possible to ensure higher simulation accuracy and determine a capture coefficient. An algorithm is elaborated of computing output characteristics based upon the mathematical model suggested. A capture coefficient, coordinate expectation characterizing an average phase value of the beam particles, coordinate expectation characterizing an average value of the reverse relative velocity of the beam particles as well as dispersion of these coordinates are output characteristics of the accelerator. Calculation methods of the accelerator output characteristics are described in detail. The computations have been performed on the BESM-6 computer, the characteristics computing time being 2 min 20 sec. Relative error of parameter computation averages 10 -2

  14. Accelerator physics analysis with an integrated toolkit

    International Nuclear Information System (INIS)

    Holt, J.A.; Michelotti, L.; Satogata, T.

    1992-08-01

    Work is in progress on an integrated software toolkit for linear and nonlinear accelerator design, analysis, and simulation. As a first application, ''beamline'' and ''MXYZPTLK'' (differential algebra) class libraries, were used with an X Windows graphics library to build an user-friendly, interactive phase space tracker which, additionally, finds periodic orbits. This program was used to analyse a theoretical lattice which contains octupoles and decapoles to find the 20th order, stable and unstable periodic orbits and to explore the local phase space structure

  15. Laser wakefield acceleration using wire produced double density ramps

    Directory of Open Access Journals (Sweden)

    M. Burza

    2013-01-01

    Full Text Available A novel approach to implement and control electron injection into the accelerating phase of a laser wakefield accelerator is presented. It utilizes a wire, which is introduced into the flow of a supersonic gas jet creating shock waves and three regions of differing plasma electron density. If tailored appropriately, the laser plasma interaction takes place in three stages: Laser self-compression, electron injection, and acceleration in the second plasma wave period. Compared to self-injection by wave breaking of a nonlinear plasma wave in a constant density plasma, this scheme increases beam charge by up to 1 order of magnitude in the quasimonoenergetic regime. Electron acceleration in the second plasma wave period reduces electron beam divergence by ≈25%, and the localized injection at the density downramps results in spectra with less than a few percent relative spread.

  16. Acompanhamento farmacoterapêutico dos pacientes com leucemia mieloide crônica em uso de mesilato de imatinibe na Universidade Federal do Ceará The pharmacotherapeutic follow- up of patients with chronic myeloid leukemia (CML on imatinib mesylate therapy

    Directory of Open Access Journals (Sweden)

    Sterfen S. Aquino

    2009-01-01

    unregulated growth of myeloid precursor cells in the bone marrow. CML is associated with a characteristic chromosomal translocation known as the Philadelphia chromosome. This is a descriptive observational study of CML patients in the Walter Cantídio University Hospital, Federal University of Ceará, Brazil. The aim of the study was to investigate the efficacy and common side effects of imatinib mesylate therapy. Twenty- six patients were included in the study: 9 in the chronic phase (34.61%, 6 in the accelerated phase (23.08% and 11 in blast crises (42.31 %. The cases in the chronic phase had previous intolerance to interferon alpha (IFN- α. Complete hematological responses were observed in 7 patients: 5 in the chronic phase, 1 in the accelerated phase and 1 in blast crisis. During the first year of treatment, 4 patients in the chronic phase presented complete cytogenetic responses. One of these patients subsequently lost response. No patient in the accelerated phase or blast crisis showed complete cytogenetic response. Complete molecular response was confirmed in 1 patient in the chronic phase. Among the 18 patients who were alive at the end of the study, only 4 patients (22.22% had no complaint. The most commonly reported adverse events were: edema (50%, adynamia (33.33%, bone and / or joint pain (33.33%, headaches (27.78%, cramps (16,67%, diarrhea (16.67%, insomnia (16.67%, itching (16.67%, ecchymosis (11.11%, nauseas (11.11%, epigastric pain (5.55%, erythema (5.55%, shedding of tears (5.55%, dehydration of the skin and lips (5.55%, rush (5.55%, and sweating (5.55%. A minority of patients evolved with imatinib resistance. Newer drugs and trials are being developed to overcome resistance and to increase responsiveness to tyrosine- kinase inhibitors.

  17. Issues to be verified by IFMIF prototype accelerator for engineering validation

    International Nuclear Information System (INIS)

    Sugimoto, M.; Imai, T.; Okumura, Y.; Nakayama, K.; Suzuki, S.; Saigusa, M.

    2002-01-01

    The validation of the accelerator technology providing the 250 mA/40 MeV continuous-wave (CW) deuteron beam with the required quality is a key issue to realize the international fusion materials irradiation facility (IFMIF). As the difficulty of high current accelerator generally comes from the low energy section due to space-charge effects, a prototype test of such a part is planned in the next development phase. The optimal choice of the prototype consists of a full-scale injector, a full-modelled radiofrequency quadrupole, and a short drift tube linear accelerator associated with a beam diagnostics/dump. Through prototype tests, the stable control of the CW accelerator at the various operational conditions will be addressed, and the technical risks of IFMIF accelerator construction can be significantly reduced

  18. Accelerator studies at cooler rings TARN and TARN II

    International Nuclear Information System (INIS)

    Katayama, Takeshi.

    1992-07-01

    Two ion cooler rings, TARN and TARN II were constructed and operated from 1975 to 1992 at the Institute for Nuclear Study, Univ. of Tokyo, for mainly accelerator studies concerning the beam accumulation, acceleration and cooling. The main subjects performed in these facilities were; 1) beam stacking in transverse and longitudinal phase spaces, 2) stochastic momentum cooling, 3) electron cooling, 4) synchrotron acceleration and 5) slow beam extraction. In the present paper, typical experimental results on these subjects, arc described as well as the basic physical idea underlying these experimental results. The technical details are out of scope of the present paper. They can be found in the other papers refered in the concerned section in the text. (author)

  19. Nonlinear cyclotron-resonance accelerations by a generalized EM wave

    International Nuclear Information System (INIS)

    Akimoto, K.; Hojo, H.

    2004-01-01

    Particle accelerations by a one-dimensional, electromagnetic, dispersive pulse in an external magnetic field are investigated. It is found that the well-known cyclotron resonance may be classified into three regimes as the length and/or the amplitude of the pulse are varied. Namely, as the pulse amplitude increases, the transit-time cyclotron-resonance acceleration (CRA) evolves to phase trapping, and reflect particles. The amplitude and wave dispersion as well as the pulse length strongly affect those accelerations. The interesting phenomena of quantization of resonance velocities in between the two regimes are also investigated. This new mechanism may lead to wave amplification at some discrete frequencies other than the cyclotron frequency. (authors)

  20. Fast digital feedback control systems for accelerator RF system using FPGA

    International Nuclear Information System (INIS)

    Bagduwal, Pritam Singh; Sharma, Dheeraj; Tiwari, Nitesh; Lad, M.; Hannurkar, P.R.

    2012-01-01

    Feedback control system plays important role for proper injection and acceleration of beam in particle accelerators by providing the required amplitude and phase stability of RF fields in accelerating structures. Advancement in the field of digital technology enables us to develop fast digital feedback control system for RF applications. Digital Low Level RF (LLRF) system offers the inherent advantages of Digital System like flexibility, adaptability, good repeatability and reduced long time drift errors compared to analog system. To implement the feedback control algorithm, I/Q control scheme is used. By properly sampling the down converted IF signal using fast ADC we get accurate feedback signal and also eliminates the need of two separate detectors for amplitude and phase detection. Controller is implemented in Vertex-4 FPGA. Codes for control algorithms which controls the amplitude and phase in all four quadrants with good accuracy are written in the VHDL. I/Q modulator works as common actuator for both amplitude and phase correction. Synchronization between RF, LO and ADC clock is indispensable and has been achieved by deriving the clock and LO signal from RF signal itself. Control system has been successfully tested in lab with phase and amplitude stability better then ±1% and ±1° respectively. High frequency RF signal is down converted to IF using the super heterodyne technique. Super heterodyne principal not only brings the RF signal to the Low IF frequency at which it can be easily processed but also enables us to use the same hardware and software for other RF frequencies with some minor modification. (author)

  1. Acceleration of tissue phase mapping by k-t BLAST: a detailed analysis of the influence of k-t-BLAST for the quantification of myocardial motion at 3T

    Directory of Open Access Journals (Sweden)

    Nienhaus G Ulrich

    2011-01-01

    Full Text Available Abstract Background The assessment of myocardial motion with tissue phase mapping (TPM provides high spatiotemporal resolution and quantitative motion information in three directions. Today, whole volume coverage of the heart by TPM encoding at high spatial and temporal resolution is limited by long data acquisition times. Therefore, a significant increase in imaging speed without deterioration of the quantitative motion information is required. For this purpose, the k-t BLAST acceleration technique was combined with TPM black-blood functional imaging of the heart. Different k-t factors were evaluated with respect to their impact on the quantitative assessment of cardiac motion. Results It is demonstrated that a k-t BLAST factor of two can be used with a marginal, but statistically significant deterioration of the quantitative motion data. Further increasing the k-t acceleration causes substantial alteration of the peak velocities and the motion pattern, but the temporal behavior of the contraction is well maintained up to an acceleration factor of six. Conclusions The application of k-t BLAST for the acceleration of TPM appears feasible. A reduction of the acquisition time of almost 45% could be achieved without substantial loss of quantitative motion information.

  2. Induction Acceleration of a Single RF Bunch in the KEK PS

    CERN Document Server

    Takayama, Ken; Arakida, Yoshio; Horioka, Kazuhiko; Igarashi, Susumu; Iwashita, Taiki; Kawasaki, Atsushi; Kishiro, Junichi; Kono, Tadaaki; Koseki, Kunio; Nakamura, Eiji; Sakuda, Makoto; Sato, Hikaru; Shiho, Makoto; Shimosaki, Yoshito; Shirakata, Masashi; Sueno, Tsuyoshi; Tokuchi, Akira; Torikai, Kota; Toyama, Takeshi; Wake, Masayoshi; Watanabe, Masao; Yamane, Isao

    2005-01-01

    A single bunch trapped in an RF bucket was accelerated by induction devices from 500 MeV to 8GeV beyond transition energy in the KEK-PS. This is the first demonstration of induction acceleration in a high energy circular ring. The acceleration was confirmed by measuring a temporal evolution of the RF phase through an entire acceleration.* Key devices in an induction acceleration system are an induction accelerating cavity capable of generating an induced voltage of 2kV/cell, a pulse modulator to drive the cavity (switching driver), and a DSP system to control gate signals for switching. Their remarkable characteristics are its repetition ratio of about 1MHz and duty factor of 50%. All devices have been newly developed at KEK so as to meet this requirement. The pulse modulator employing MOSFETs as switching elements is connected with the accelerating cavity through a long transmission cable in order to avoid a high-dose irradiation in the accelerator tunnel. The induction system has been running beyond more th...

  3. Laser power sources and laser technology for accelerators

    International Nuclear Information System (INIS)

    Lowenthal, D.

    1986-01-01

    The requirements on laser power sources for advanced accelerator concepts are formidable. These requirements are driven by the need to deliver 5 TeV particles at luminosities of 10/sup 33/ - 10/sup 34/ cm/sup -2/ sec/sup -1/. Given that optical power can be transferred efficiently to the particles these accelerator parameters translate into single pulse laser output energies of several kilojoules and rep rates of 1-10 kHz. The average laser output power is then 10-20 MW. Larger average powers will be needed if efficient transfer proves not to be possible. A laser plant of this magnitude underscores the importance of high wall plug efficiency and reasonable cost in $/Watt. The interface between the laser output pulse format and the accelerator structure is another area that drives the laser requirements. Laser accelerators break up into two general architectures depending on the strength of the laser coupling. For strong coupling mechanisms, the architecture requires many ''small'' lasers powering the accelerator in a staged arrangement. For the weak coupling mechanisms, the architecture must feature a single large laser system whose power must be transported along the entire accelerator length. Both of these arrangements have demanding optical constraints in terms of phase matching sequential stages, beam combining arrays of laser outputs and optimizing coupling of laser power in a single accelerating stage

  4. Spectroscopic measurements of plasma emission light for plasma-based acceleration experiments

    International Nuclear Information System (INIS)

    Filippi, F.; Mostacci, A.; Palumbo, L.; Anania, M.P.; Biagioni, A.; Chiadroni, E.; Ferrario, M.; Cianchi, A.; Zigler, A.

    2016-01-01

    Advanced particle accelerators are based on the excitation of large amplitude plasma waves driven by either electron or laser beams. Future experiments scheduled at the SPARC-LAB test facility aim to demonstrate the acceleration of high brightness electron beams through the so-called resonant Plasma Wakefield Acceleration scheme in which a train of electron bunches (drivers) resonantly excites wakefields into a preformed hydrogen plasma; the last bunch (witness) injected at the proper accelerating phase gains energy from the wake. The quality of the accelerated beam depends strongly on plasma density and its distribution along the acceleration length. The measurements of plasma density of the order of 10 16 –10 17  cm −3 can be performed with spectroscopic measurements of the plasma-emitted light. The measured density distribution for hydrogen filled capillary discharge with both Balmer alpha and Balmer beta lines and shot-to-shot variation are here reported.

  5. Spectroscopic measurements of plasma emission light for plasma-based acceleration experiments

    Science.gov (United States)

    Filippi, F.; Anania, M. P.; Biagioni, A.; Chiadroni, E.; Cianchi, A.; Ferrario, M.; Mostacci, A.; Palumbo, L.; Zigler, A.

    2016-09-01

    Advanced particle accelerators are based on the excitation of large amplitude plasma waves driven by either electron or laser beams. Future experiments scheduled at the SPARC_LAB test facility aim to demonstrate the acceleration of high brightness electron beams through the so-called resonant Plasma Wakefield Acceleration scheme in which a train of electron bunches (drivers) resonantly excites wakefields into a preformed hydrogen plasma; the last bunch (witness) injected at the proper accelerating phase gains energy from the wake. The quality of the accelerated beam depends strongly on plasma density and its distribution along the acceleration length. The measurements of plasma density of the order of 1016-1017 cm-3 can be performed with spectroscopic measurements of the plasma-emitted light. The measured density distribution for hydrogen filled capillary discharge with both Balmer alpha and Balmer beta lines and shot-to-shot variation are here reported.

  6. Characterization of Vertical Impact Device Acceleration Pulses Using Parametric Assessment: Phase 3 Wiaman Seat

    Science.gov (United States)

    2016-07-01

    711 HPW/RHCPT) and their in-house technical support contractor , Infoscitex, conducted a series of tests to identify the performance capabilities of...Cell Seat Configuration Drop Ht . (in) Mean Peak Acceleration (G) Mean Velocity Change (ft/s) SH1 WS1 20 80.08 ± 3.71 13.54 ± 0.49 SH2...6. Test Matrix for VID Response with WS2 Test Cell Seat (Felt) Configuration Drop Ht . (in) Mean Peak Acceleration (G

  7. Simulation Studies of the Dielectric Grating as an Accelerating and Focusing Structure

    International Nuclear Information System (INIS)

    Soong, Ken; Peralta, E.A.; Byer, R.L.; Colby, E.

    2011-01-01

    A grating-based design is a promising candidate for a laser-driven dielectric accelerator. Through simulations, we show the merits of a readily fabricated grating structure as an accelerating component. Additionally, we show that with a small design perturbation, the accelerating component can be converted into a focusing structure. The understanding of these two components is critical in the successful development of any complete accelerator. The concept of accelerating electrons with the tremendous electric fields found in lasers has been proposed for decades. However, until recently the realization of such an accelerator was not technologically feasible. Recent advances in the semiconductor industry, as well as advances in laser technology, have now made laser-driven dielectric accelerators imminent. The grating-based accelerator is one proposed design for a dielectric laser-driven accelerator. This design, which was introduced by Plettner, consists of a pair of opposing transparent binary gratings, illustrated in Fig. 1. The teeth of the gratings serve as a phase mask, ensuring a phase synchronicity between the electromagnetic field and the moving particles. The current grating accelerator design has the drive laser incident perpendicular to the substrate, which poses a laser-structure alignment complication. The next iteration of grating structure fabrication seeks to monolithically create an array of grating structures by etching the grating's vacuum channel into a fused silica wafer. With this method it is possible to have the drive laser confined to the plane of the wafer, thus ensuring alignment of the laser-and-structure, the two grating halves, and subsequent accelerator components. There has been previous work using 2-dimensional finite difference time domain (2D-FDTD) calculations to evaluate the performance of the grating accelerator structure. However, this work approximates the grating as an infinite structure and does not accurately model a

  8. Bacterial Contribution in Chronicity of Wounds.

    Science.gov (United States)

    Rahim, Kashif; Saleha, Shamim; Zhu, Xudong; Huo, Liang; Basit, Abdul; Franco, Octavio Luiz

    2017-04-01

    A wound is damage of a tissue usually caused by laceration of a membrane, generally the skin. Wound healing is accomplished in three stages in healthy individuals, including inflammatory, proliferative, and remodeling stages. Healing of wounds normally starts from the inflammatory phase and ends up in the remodeling phase, but chronic wounds remain in an inflammatory stage and do not show progression due to some specific reasons. Chronic wounds are classified in different categories, such as diabetic foot ulcer (DFU), venous leg ulcers (VLU) and pressure ulcer (PU), surgical site infection (SSI), abscess, or trauma ulcers. Globally, the incidence rate of DFU is 1-4 % and prevalence rate is 5.3-10.5 %. However, colonization of pathogenic bacteria at the wound site is associated with wound chronicity. Most chronic wounds contain more than one bacterial species and produce a synergetic effect that results in previously non-virulent bacterial species becoming virulent and causing damage to the host. While investigating bacterial diversity in chronic wounds, Staphylococcus, Pseudomonas, Peptoniphilus, Enterobacter, Stenotrophomonas, Finegoldia, and Serratia were found most frequently in chronic wounds. Recently, it has been observed that bacteria in chronic wounds develop biofilms that contribute to a delay in healing. In a mature biofilm, bacteria grow slowly due to deficiency of nutrients that results in the resistance of bacteria to antibiotics. The present review reflects the reasons why acute wounds become chronic. Interesting findings include the bacterial load, which forms biofilms and shows high-level resistance toward antibiotics, which is a threat to human health in general and particularly to some patients who have acute wounds.

  9. The R/D of high power proton accelerator technology in China

    Science.gov (United States)

    Xialing, Guan

    2002-12-01

    In China, a multipurpose verification system as a first phase of our ADS program consists of a low energy accelerator (150 MeV/3 mA proton LINAC) and a swimming pool light water subcritical reactor. In this paper the activities of HPPA technology related to ADS in China, which includes the intense proton ECR source, the RFQ accelerator and some other technology of HPPA, are described.

  10. Preliminary results of phase I/II study of simultaneous modulated accelerated (SMART) for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Hong; Lee, Sang Wook; Back, Geum Mun [College of Medicine, University of Ulsan, Asan Medical Center, Seoul (Korea, Republic of)] (and others)

    2006-03-15

    To present preliminary results of intensity-modulated radiotherapy (IMRT) using the simultaneous modulated accelerated radiation therapy (SMART) boost technique in patients with nasopharyngeal carcinoma (NPC). Twenty patients who underwent IMRT for non-metastatic NPC at the Asan Medical Center between September 2001 and December 2003 were prospectively evaluated. IMRT was delivered using the 'step and shoot' SMART technique at prescribed doses of 72 Gy (2.4 Gy/day) to the gross tumor volume (GTV), 60 Gy (2 Gy/day) to the clinical target volume (CTV) and metastatic nodal station, and 46 Gy (2 Gy/day) to the clinically negative neck region. Eighteen patients also received concurrent chemotherapy using cisplatin once per week. The median follow-up period was 27 months. Nineteen patients completed the treatment without interruption; the remaining patient interrupted treatment for 2 weeks owing to severe pharyngitis and malnutrition. Five patients (25%) had RTOG grade 3 mucositis, whereas nine (45%) had grade 3 pharyngitis. Seven patients (35%) lost more than 10% of their pretreatment weight, whereas 11 (55%) required intravenous fluids and/or tube feeding. There was no grade 3 or 4 chronic xerostomia. All patients showed complete response. Two patients had distant metastases and loco-regional recurrence, respectively. IMRT using the SMART boost technique allows parotid sparing, as shown clinically and by dosimetry, and may also be more effective biologically. A larger population of patients and a longer follow-up period are needed to evaluate ultimate tumor control and late toxicity.

  11. Movement coordination and differential kinematics of the cervical and thoracic spines in people with chronic neck pain.

    Science.gov (United States)

    Tsang, Sharon M H; Szeto, Grace P Y; Lee, Raymond Y W

    2013-07-01

    Research on the kinematics and inter-regional coordination of movements between the cervical and thoracic spines in motion adds to our understanding of the performance and interplay of these spinal regions. The purpose of this study was to examine the effects of chronic neck pain on the three-dimensional kinematics and coordination of the cervical and thoracic spines during active movements of the neck. Three-dimensional spinal kinematics and movement coordination between the cervical, upper thoracic, and lower thoracic spines were examined by electromagnetic motion sensors in thirty-four individuals with chronic neck pain and thirty-four age- and gender-matched asymptomatic subjects. All subjects performed a set of free active neck movements in three anatomical planes in sitting position and at their own pace. Spinal kinematic variables (angular displacement, velocity, and acceleration) of the three defined regions, and movement coordination between regions were determined and compared between the two groups. Subjects with chronic neck pain exhibited significantly decreased cervical angular velocity and acceleration of neck movement. Cross-correlation analysis revealed consistently lower degrees of coordination between the cervical and upper thoracic spines in the neck pain group. The loss of coordination was most apparent in angular velocity and acceleration of the spine. Assessment of the range of motion of the neck is not sufficient to reveal movement dysfunctions in chronic neck pain subjects. Evaluation of angular velocity and acceleration and movement coordination should be included to help develop clinical intervention strategies to promote restoration of differential kinematics and movement coordination. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Uraemia progression in chronic kidney disease stages 3-5 is not constant

    DEFF Research Database (Denmark)

    Heaf, James Goya; Mortensen, Leif Spange

    2011-01-01

    Chronic kidney disease (CKD) is a progressive disease leading to loss of glomerular filtration rate (ΔGFR, measured in ml/min/1.73 m(2)/year). ΔGFR is usually assumed to be constant, but the hyperfiltration theory suggests that it accelerates in severe uraemia. A retrospective analysis of estimated...... GFR (eGFR) calculated from the Modification of Diet in Renal Disease equation was performed to evaluate whether ΔGFR is constant or accelerating....

  13. Posttransplant Immune Activation: Innocent Bystander or Insidious Culprit of Posttransplant Accelerated Atherosclerosis.

    Science.gov (United States)

    Ducloux, Didier; Bamoulid, Jamal; Crepin, Thomas; Rebibou, Jean-Michel; Courivaud, Cecile; Saas, Philippe

    2017-09-01

    Cardiovascular disease is a major cause of morbidity, disability, and mortality in kidney transplant patients. Cumulative reports indicate that the excessive risk of cardiovascular events is not entirely explained by the increased prevalence of traditional cardiovascular risk factors. Atherosclerosis is a chronic inflammatory disease, and it has been postulated that posttransplant immune disturbances may explain the gap between the predicted and observed risks of cardiovascular events. Although concordant data suggest that innate immunity contributes to the posttransplant accelerated atherosclerosis, only few arguments plead for a role of adaptive immunity. We report and discuss here consistent data demonstrating that CD8 + T cell activation is a frequent posttransplant immune feature that may have pro-atherogenic effects. Expansion of exhausted/activated CD8 + T cells in kidney transplant recipients is stimulated by several factors including cytomegalovirus infections, lymphodepletive therapy (e.g., antithymocyte globulins), chronic allogeneic stimulation, and a past history of renal insufficiency. This is observed in the setting of decreased thymic activity, a process also found in elderly individuals and reflecting accelerated immune senescence.

  14. Accelerated life testing effects on CMOS microcircuit characteristics, phase 1

    Science.gov (United States)

    Maximow, B.

    1976-01-01

    An accelerated life test of sufficient duration to generate a minimum of 50% cumulative failures in lots of CMOS devices was conducted to provide a basis for determining the consistency of activation energy at 250 C. An investigation was made to determine whether any thresholds were exceeded during the high temperature testing, which could trigger failure mechanisms unique to that temperature. The usefulness of the 250 C temperature test as a predictor of long term reliability was evaluated.

  15. Rf system specifications for a linear accelerator

    International Nuclear Information System (INIS)

    Young, A.; Eaton, L.E.

    1992-01-01

    A linear accelerator contains many systems; however, the most complex and costly is the RF system. The goal of an RF system is usually simply stated as maintaining the phase and amplitude of the RF signal within a given tolerance to accelerate the charged particle beam. An RF system that drives a linear accelerator needs a complete system specification, which should contain specifications for all the subsystems (i.e., high-power RF, low-level RF, RF generation/distribution, and automation control). This paper defines a format for the specifications of these subsystems and discusses each RF subsystem independently to provide a comprehensive understanding of the function of each subsystem. This paper concludes with an example of a specification spreadsheet allowing one to input the specifications of a subsystem. Thus, some fundamental parameters (i.e., the cost and size) of the RF system can be determined

  16. Impulsive ion acceleration in earth's outer magnetosphere

    International Nuclear Information System (INIS)

    Baker, D.N.; Belian, R.D.

    1985-01-01

    Considerable observational evidence is found that ions are accelerated to high energies in the outer magnetosphere during geomagnetic disturbances. The acceleration often appears to be quite impulsive causing temporally brief (10's of seconds), very intense bursts of ions in the distant plasma sheet as well as in the near-tail region. These ion bursts extend in energy from 10's of keV to over 1 MeV and are closely associated with substorm expansive phase onsets. Although the very energetic ions are not of dominant importance for magnetotail plasma dynamics, they serve as an important tracer population. Their absolute intensity and brief temporal appearance bespeaks a strong and rapid acceleration process in the near-tail, very probably involving large induced electric fields substantially greater than those associated with cross-tail potential drops. Subsequent to their impulsive acceleration, these ions are injected into the outer trapping regions forming ion ''drift echo'' events, as well as streaming tailward away from their acceleration site in the near-earth plasma sheet. Most auroral ion acceleration processes occur (or are greatly enhanced) during the time that these global magnetospheric events are occurring in the magnetotail. A qualitative model relating energetic ion populations to near-tail magnetic reconnection at substorm onset followed by global redistribution is quite successful in explaining the primary observational features. Recent measurements of the elemental composition and charge-states have proven valuable for showing the source (solar wind or ionosphere) of the original plasma population from which the ions were accelerated

  17. An accelerated dose escalation with a grass pollen allergoid is safe and well-tolerated: a randomized open label phase II trial.

    Science.gov (United States)

    Chaker, A M; Al-Kadah, B; Luther, U; Neumann, U; Wagenmann, M

    2015-01-01

    The number of injections in the dose escalation of subcutaneous immunotherapy (SCIT) is small for some currently used hypoallergenic allergoids, but can still be inconvenient to patients and can impair compliance. The aim of this trial was to compare safety and tolerability of an accelerated to the conventional dose escalation scheme of a grass pollen allergoid. In an open label phase II trial, 122 patients were 1:1 randomized for SCIT using a grass pollen allergoid with an accelerated dose escalation comprising only 4 weekly injections (Group I) or a conventional dose escalation including 7 weekly injections (Group II). Safety determination included the occurrence of local and systemic adverse events. Tolerability was assessed by patients and physicians. Treatment-related adverse events were observed in 22 (36.1 %) patients in Group I and 15 (24.6 %) in Group II. Local reactions were reported by 18 patients in Group I and 11 in Group II. Five Grade 1 systemic reactions (WAO classification) were observed in Group I and 2 in Group II. Grade 2 reactions occurred 3 times in Group I and 2 times in Group II. Tolerability was rated as "good" or "very good" by 53 (86.9 %) patients in Group I and 59 (100 %) in Group II by investigators. Forty-eight patients in Group I (80.0 %) and 54 in Group II (91.5 %) rated tolerability as "good" or "very good". The dose escalation of a grass pollen allergoid can be accelerated with safety and tolerability profiles comparable to the conventional dose escalation.

  18. Superconducting Magnets for Accelerators

    Science.gov (United States)

    Brianti, G.; Tortschanoff, T.

    1993-03-01

    This chapter describes the main features of superconducting magnets for high energy synchrotrons and colliders. It refers to magnets presently used and under development for the most advanced accelerators projects, both recently constructed or in the preparatory phase. These magnets, using the technology mainly based on the NbTi conductor, are described from the aspect of design, materials, construction and performance. The trend toward higher performance can be gauged from the doubling of design field in less than a decade from about 4 T for the Tevatron to 10 T for the LHC. Special properties of the superconducting accelerator magnets, such as their general layout and the need of extensive computational treatment, the limits of performance inherent to the available conductors, the requirements on the structural design are described. The contribution is completed by elaborating on persistent current effects, quench protection and the cryostat design. As examples the main magnets for HERA and SSC, as well as the twin-aperture magnets for LHC, are presented.

  19. Screened selection design for randomised phase II oncology trials: an example in chronic lymphocytic leukaemia.

    Science.gov (United States)

    Yap, Christina; Pettitt, Andrew; Billingham, Lucinda

    2013-07-03

    As there are limited patients for chronic lymphocytic leukaemia trials, it is important that statistical methodologies in Phase II efficiently select regimens for subsequent evaluation in larger-scale Phase III trials. We propose the screened selection design (SSD), which is a practical multi-stage, randomised Phase II design for two experimental arms. Activity is first evaluated by applying Simon's two-stage design (1989) on each arm. If both are active, the play-the-winner selection strategy proposed by Simon, Wittes and Ellenberg (SWE) (1985) is applied to select the superior arm. A variant of the design, Modified SSD, also allows the arm with the higher response rates to be recommended only if its activity rate is greater by a clinically-relevant value. The operating characteristics are explored via a simulation study and compared to a Bayesian Selection approach. Simulations showed that with the proposed SSD, it is possible to retain the sample size as required in SWE and obtain similar probabilities of selecting the correct superior arm of at least 90%; with the additional attractive benefit of reducing the probability of selecting ineffective arms. This approach is comparable to a Bayesian Selection Strategy. The Modified SSD performs substantially better than the other designs in selecting neither arm if the underlying rates for both arms are desirable but equivalent, allowing for other factors to be considered in the decision making process. Though its probability of correctly selecting a superior arm might be reduced, it still performs reasonably well. It also reduces the probability of selecting an inferior arm. SSD provides an easy to implement randomised Phase II design that selects the most promising treatment that has shown sufficient evidence of activity, with available R codes to evaluate its operating characteristics.

  20. The relation of airway obstruction to asthma, chronic rhinosinusitis and age

    DEFF Research Database (Denmark)

    Obaseki, D; Potts, J; Joos, G

    2014-01-01

    RATIONALE: There is conflicting evidence on whether patients with asthma experience an accelerated decline in lung function with age. We examined the association between postbronchodilator lung function, asthma, chronic rhinosinusitis (CRS), and atopy with age using a large European sample. METHO...

  1. Traveling wave accelerating structures with a large phase advance

    International Nuclear Information System (INIS)

    Paramonov, V.V.

    2012-01-01

    The cells RF parameters for the well known Disk Loaded Waveguide (DLW) are considered in higher pass bands of TM01 wave, providing operating phase advance between 180 o - 1230 o per cell. With an appropriate shape optimization and some additional elements proposed traveling wave structures with such large phase advance overlap the classical first band DLW in RF efficiency. Examples of proposed structures together with RF and dispersion properties are presented.

  2. Focal spot motion of linear accelerators and its effect on portal image analysis

    NARCIS (Netherlands)

    Sonke, Jan-Jakob; Brand, Bob; van Herk, Marcel

    2003-01-01

    The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of

  3. Modeling of electron cyclotron resonance acceleration in a stationary inhomogeneous magnetic field

    Directory of Open Access Journals (Sweden)

    Valeri D. Dougar-Jabon

    2008-04-01

    Full Text Available In this paper, the cyclotron autoresonance acceleration of electrons in a stationary inhomogeneous magnetic field is studied. The trajectory and energy of electrons are found through a numerical solution of the relativistic Newton-Lorentz equation by a finite difference method. The electrons move along a TE_{112} cylinder cavity in a steady-state magnetic field whose axis coincides with the cavity axis. The magnetic field profile is such that it keeps the phase difference between the electric microwave field and the electron velocity vector within the acceleration phase band. The microwaves amplitude of 6  kV/cm is used for numerical calculations. It is shown that an electron with an initial longitudinal energy of 8 keV can be accelerated up to 260 keV by 2.45 GHz microwaves at a distance of 17 cm.

  4. Demonstration of two-beam acceleration in CTF II

    CERN Document Server

    Bossart, Rudolf; Carron, G; Chanudet, M; Chautard, F; Delahaye, J P; Godot, J C; Hutchins, S; Kamber, I; Martínez, C; Suberlucq, Guy; Tenenbaum, P G; Thorndahl, L; Valentini, M; Wilson, Ian H; Wuensch, Walter

    1999-01-01

    The second phase of the Compact LInear Collider (CLIC) Test Facility (CTF II) at CERN has demon-strated the feasibility of two-beam acceleration at 30 GHz using a high-charge drive beam, running paral lel to the main beam, as the RF power source. To date accelerating gradients of 59 MV/m at 30 GHz have been achieved. In CTF II, the two beams are generated by 3 GHz RF photo-injectors and are acceler ated in 3 GHz linacs, before injection into the 30 GHz modules. The drive beam linac has to accelerate a 16 ns long train of 48 bunches, each with a nominal charge of 13.4 nC. To cope with the very su bstantial beam-loading special accelerating structures are used (running slightly off the bunch repetition frequency). A magnetic chicane compresses the bunches to less than 5 ps fwhm, this is needed for efficient 30 GHz power generation. The 30 GHz modules are fully-engineered representative sections of CLIC, they include a 30 GHz decelerator for the drive beam, a 30 GHz accelerator for the main beam, high resolution...

  5. Enhanced dielectric-wall linear accelerator

    Science.gov (United States)

    Sampayan, Stephen E.; Caporaso, George J.; Kirbie, Hugh C.

    1998-01-01

    A dielectric-wall linear accelerator is enhanced by a high-voltage, fast e-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.

  6. Defining the neural fulcrum for chronic vagus nerve stimulation: implications for integrated cardiac control.

    Science.gov (United States)

    Ardell, Jeffrey L; Nier, Heath; Hammer, Matthew; Southerland, E Marie; Ardell, Christopher L; Beaumont, Eric; KenKnight, Bruce H; Armour, J Andrew

    2017-11-15

    VNS active phase owing to afferent modulation of parasympathetic central drive. When functional effects of afferent and efferent fibre activation were balanced, a null HRR was evoked (defined as 'neural fulcrum') during which HRR ≈ 0. As intensity increased further, HR was reduced during the active phase of VNS. While qualitatively similar, VNS delivered in the epilepsy configuration resulted in more pronounced HR acceleration and reduced HR deceleration during VNS. At termination, under anaesthesia, transection of the vagi rostral to the stimulation site eliminated the augmenting response to VNS and enhanced the parasympathetic efferent-mediated suppressing effect on electrical and mechanical function of the heart. In conclusion, VNS activates central then peripheral aspects of the cardiac nervous system. VNS control over cardiac function is maintained during chronic therapy. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.

  7. Spinal neuropeptide expression and neuropathic behavior in the acute and chronic phases after spinal cord injury: Effects of progesterone administration.

    Science.gov (United States)

    Coronel, María F; Villar, Marcelo J; Brumovsky, Pablo R; González, Susana L

    2017-02-01

    Patients with spinal cord injury (SCI) develop chronic pain that severely compromises their quality of life. We have previously reported that progesterone (PG), a neuroprotective steroid, could offer a promising therapeutic strategy for neuropathic pain. In the present study, we explored temporal changes in the expression of the neuropeptides galanin and tyrosine (NPY) and their receptors (GalR1 and GalR2; Y1R and Y2R, respectively) in the injured spinal cord and evaluated the impact of PG administration on both neuropeptide systems and neuropathic behavior. Male rats were subjected to spinal cord hemisection at T13 level, received daily subcutaneous injections of PG or vehicle, and were evaluated for signs of mechanical and thermal allodynia. Real time PCR was used to determine relative mRNA levels of neuropeptides and receptors, both in the acute (1day) and chronic (28days) phases after injury. A significant increase in Y1R and Y2R expression, as well as a significant downregulation in GalR2 mRNA levels, was observed 1day after SCI. Interestingly, PG early treatment prevented Y1R upregulation and resulted in lower NPY, Y2R and GalR1 mRNA levels. In the chronic phase, injured rats showed well-established mechanical and cold allodynia and significant increases in galanin, NPY, GalR1 and Y1R mRNAs, while maintaining reduced GalR2 expression. Animals receiving PG treatment showed basal expression levels of galanin, NPY, GalR1 and Y1R, and reduced Y2R mRNA levels. Also, and in line with previously published observations, PG-treated animals did not develop mechanical allodynia and showed reduced sensitivity to cold stimulation. Altogether, we show that SCI leads to considerable changes in the spinal expression of galanin, NPY and their associated receptors, and that early and sustained PG administration prevents them. Moreover, our data suggest the participation of galaninergic and NPYergic systems in the plastic changes associated with SCI-induced neuropathic pain

  8. Significance of acceleration period in a dynamic strength testing study.

    Science.gov (United States)

    Chen, W L; Su, F C; Chou, Y L

    1994-06-01

    The acceleration period that occurs during isokinetic tests may provide valuable information regarding neuromuscular readiness to produce maximal contraction. The purpose of this study was to collect the normative data of acceleration time during isokinetic knee testing, to calculate the acceleration work (Wacc), and to determine the errors (ERexp, ERwork, ERpower) due to ignoring Wacc during explosiveness, total work, and average power measurements. Seven male and 13 female subjects attended the test by using the Cybex 325 system and electronic stroboscope machine for 10 testing speeds (30-300 degrees/sec). A three-way ANOVA was used to assess gender, direction, and speed factors on acceleration time, Wacc, and errors. The results indicated that acceleration time was significantly affected by speed and direction; Wacc and ERexp by speed, direction, and gender; and ERwork and ERpower by speed and gender. The errors appeared to increase when testing the female subjects, during the knee flexion test, or when speed increased. To increase validity in clinical testing, it is important to consider the acceleration phase effect, especially in higher velocity isokinetic testing or for weaker muscle groups.

  9. Accelerating and focusing structures for PIGMI

    International Nuclear Information System (INIS)

    Swenson, D.A.; Bush, E.D. Jr.; Holsinger, R.F.; Manca, J.J.; Saito, N.; Stovall, J.E.

    1977-01-01

    The National Cancer Institute is supporting a program of accelerator development at the Los Alamos Scientific Laboratory aimed at the extension of proton linac technologies to produce the most suitable Pion Generator for Medical Irradiations (PIGMI). An optimized design of a pion generator suitable for a radiotherapy program at a major medical center has been established, consisting of a 250-keV injector, followed by a 35-meter-long drift-tube linac that accelerates the proton beam to 150 MeV, and an 85-meter-long coupled-cavity linac that accelerates the beam to its final energy of 650 MeV, where the average beam current of 100 microamperes impinges on one or more targets producing abundant quantities of π - mesons for radiotherapeutic applications. A number of extensions to proton linac technology are being pursued under the PIGMI program at LASL. A discussion is given of recent developments in three areas relevant to the acceleration and focusing of proton beams, namely, the alternating phase focused (APF) linac structure, the disk and washer linac structure, and small permanent magnet quadrupole lenses. The APF linac structure is being developed for the acceleration and focusing role from the injection energy of 250 keV to a few MeV, where a transition is made to a permanent magnet quadrupole focused linac structure. The disk and washer linac structure is under consideration for the high velocity portion of the design

  10. Steady state ion acceleration by a circularly polarized laser pulse

    International Nuclear Information System (INIS)

    Zhang Xiaomei; Shen Baifei; Cang Yu; Li Xuemei; Jin Zhangying; Wang Fengchao

    2007-01-01

    The steady state ion acceleration at the front of a cold solid target by a circularly polarized flat-top laser pulse is studied with one-dimensional particle-in-cell (PIC) simulation. A model that ions are reflected by a steady laser-driven piston is used by comparing with the electrostatic shock acceleration. A stable profile with a double-flat-top structure in phase space forms after ions enter the undisturbed region of the target with a constant velocity

  11. Tuning of Clic accelerating structure prototypes at CERN

    CERN Document Server

    Shi, J; Olyunin, A; Wuensch, W

    2010-01-01

    An RF measurement system has been set up at CERN for use in the X-band accelerating structure development program of the CLIC study. Using the system, S-parameters are measured and the field distribution is obtained automatically using a bead-pull technique. The corrections for tuning the structure are calculated from an initial measurement and cell-by-cell tuning is applied to obtain the correct phase advance and minimum reflection at the operation frequency. The detailed tuning procedure is presented and explained along with an example of measurement and tuning of CLIC accelerating structure prototypes.

  12. 3D Metallic Lattices for Accelerator Applications

    CERN Document Server

    Shapiro, Michael A; Sirigiri, Jagadishwar R; Temkin, Richard J

    2005-01-01

    We present the results of research on 3D metallic lattices operating at microwave frequencies for application in (1) accelerator structures with higher order mode suppression, (2) Smith-Purcell radiation beam diagnostics, and (3) polaritonic materials for laser acceleration. Electromagnetic waves in a 3D simple cubic lattice formed by metal wires are calculated using HFSS. The bulk modes in the lattice are determined using single cell calculations with different phase advances in all three directions. The Brillouin diagram for the bulk modes is presented and indicates the absence of band gaps in simple lattices except the band below the cutoff. Lattices with thin wires as well as with thick wires have been analyzed. The Brillouin diagram also indicates the presence of low frequency 3D plasmon mode as well as the two degenerate photon modes analogous to those in a 2D lattice. Surface modes for a semi-infinite cubic lattice are modeled as a stack of cells with different phase advances in the two directions alon...

  13. Charged particle and photon acceleration by wakefield plasma waves in non-uniform plasmas

    International Nuclear Information System (INIS)

    Bulanov, S.V.; Kirsanov, V.I.; Sakharov, A.S.; Pegoraro, F.

    1993-01-01

    We discuss the acceleration of charged particles and the upshift of the frequency of short wave packets of laser radiation. The acceleration and the upshift are caused by wake plasma waves excited by a strong laser pulse in a non-uniform plasma. We show that unlimited acceleration of charged particles is possible for specific spatial dependencies of the plasma density. In this unlimited acceleration regime, particles have a fixed phase relationship with respect to the plasma wave, while their energy increases with time. When the wave breaking limit is approached and surpassed, the efficiency of the acceleration of the charged particles and of the frequency upshift of the photons can be increased significantly. (author) 3 refs

  14. Design Considerations of a Novel Two-Beam Accelerator

    Science.gov (United States)

    Luginsland, John William

    This thesis reports the design study of a new type of charged particle accelerator called the Twobetron. The accelerator consists of two beams of electrons traveling through a series of pillbox cavities. The power of a high current annular beam excites an electromagnetic mode in the cavities, which, in turn, drives a low current on-axis pencil beam to high energy. We focus on the design considerations that would make use of existing pulsed power systems, for a proof-of-principle experiment. Potential applications of this new device include radiotherapy, materials processing, and high energy accelerators. The first phase of the research involves analytic description of the accelerating process. This reveals the problem of phase slippage. Derbenev's proposed cure of beam radius modulation is analyzed. Further studies include the effect of initial phase and secondary beam loading. Scaling laws to characterize the Twobetron's performance are derived. Computer simulation is performed to produce a self-consistent analysis of the dynamics of the space charge and its interaction with the accelerator structure. Particle -in-cell simulations answer several questions concerning beam stability, cavity modes, and the nature of the structure. Specifically, current modulation on the primary beam is preserved in the simulations. However, these simulations also revealed that mode competition and significant cavity coupling are serious issues that need to be addressed. Also considered is non-axisymmetric instability on the driver beam of the Twobetron, in particular, the beam breakup instability (BBU), which is known to pose a serious threat to linear accelerators in general. We extend the classical analysis of BBU to annular beams. The effect of higher order non-axisymmetric modes is also examined. It is shown that annular beams are more stable than pencil beams to BBU in general. Our analysis also reveals that the rf magnetic field is more important than the rf electric field in

  15. Cybermaterials: materials by design and accelerated insertion of materials

    Science.gov (United States)

    Xiong, Wei; Olson, Gregory B.

    2016-02-01

    Cybermaterials innovation entails an integration of Materials by Design and accelerated insertion of materials (AIM), which transfers studio ideation into industrial manufacturing. By assembling a hierarchical architecture of integrated computational materials design (ICMD) based on materials genomic fundamental databases, the ICMD mechanistic design models accelerate innovation. We here review progress in the development of linkage models of the process-structure-property-performance paradigm, as well as related design accelerating tools. Extending the materials development capability based on phase-level structural control requires more fundamental investment at the level of the Materials Genome, with focus on improving applicable parametric design models and constructing high-quality databases. Future opportunities in materials genomic research serving both Materials by Design and AIM are addressed.

  16. Primary peak and chronic malaria infection levels are correlated in experimentally infected great reed warblers.

    Science.gov (United States)

    Asghar, Muhammad; Westerdahl, Helena; Zehtindjiev, Pavel; Ilieva, Mihaela; Hasselquist, Dennis; Bensch, Staffan

    2012-09-01

    Malaria parasites often manage to maintain an infection for several months or years in their vertebrate hosts. In humans, rodents and birds, most of the fitness costs associated with malaria infections are in the short initial primary (high parasitaemia) phase of the infection, whereas the chronic phase (low parasitaemia) is more benign to the host. In wild birds, malaria parasites have mainly been studied during the chronic phase of the infection. This is because the initial primary phase of infection is short in duration and infected birds with severe disease symptoms tend to hide in sheltered places and are thus rarely caught and sampled. We therefore wanted to investigate the relationship between the parasitaemia during the primary and chronic phases of the infection using an experimental infection approach. We found a significant positive correlation between parasitaemia in the primary peak and the subsequent chronic phase of infection when we experimentally infected great reed warblers (Acrocephalus arundinaceus) with Plasmodium ashfordi. The reason for this association remains to be understood, but might arise from individual variation in exoerythrocytic parasite reservoirs in hosts, parasite antigenic diversity and/or host genetics. Our results suggest that the chronic phase parasitaemia can be used to qualitatively infer the parasitaemia of the preceding and more severe primary phase, which is a very important finding for studies of avian malaria in wild populations.

  17. Sled Towing Acutely Decreases Acceleration Sprint Time.

    Science.gov (United States)

    Wong, Megan A; Dobbs, Ian J; Watkins, Casey M; Barillas, Saldiam R; Lin, Anne; Archer, David C; Lockie, Robert G; Coburn, Jared W; Brown, Lee E

    2017-11-01

    Wong, MA, Dobbs, IJ, Watkins, C, Barillas, SR, Lin, A, Archer, DC, Lockie, RG, Coburn, JW, and Brown, LE. Sled towing acutely decreases acceleration sprint time. J Strength Cond Res 31(11): 3046-3051, 2017-Sled towing is a common form of overload training in sports to develop muscular strength for sprinting. This type of training leads to acute and chronic outcomes. Acute training potentially leads to postactivation potentiation (PAP), which is when subsequent muscle performance is enhanced after a preload stimulus. The purpose of this study was to determine differences between rest intervals after sled towing on acute sprint speed. Twenty healthy recreationally trained men (age = 22.3 ± 2.4 years, height = 176.95 ± 5.46 cm, mass = 83.19 ± 11.31 kg) who were currently active in a field sport twice a week for the last 6 months volunteered to participate. A maximal 30-meter (m) baseline (BL) body mass (BM) sprint was performed (with splits at 5, 10, 20, and 30 m) followed by 5 visits where participants sprinted 30 m towing a sled at 30% BM then rested for 2, 4, 6, 8, or 12 minutes. They were instructed to stand still during rest times. After the rest interval, they performed a maximal 30-m post-test BM sprint. Analysis of variance (ANOVA) revealed that post sled tow BM sprint times (4.47 ± 0.21 seconds) were less than BL times (4.55 ± 0.18 seconds) on an individualized rest interval basis. A follow-up 2 × 4 ANOVA showed that this decrease occurred only in the acceleration phase over the first 5 m (BL = 1.13 ± 0.08 seconds vs. Best = 1.08 ± 0.08 seconds), which may be the result of PAP and the complex relationship between fatigue and potentiation relative to the intensity of the sled tow and the rest interval. Therefore, coaches should test their athletes on an individual basis to determine optimal rest time after a 30-m 30% BM sled tow to enhance acute sprint speed.

  18. Machine protection: availability for particle accelerators

    International Nuclear Information System (INIS)

    Apollonio, A.

    2015-01-01

    Machine availability is a key indicator for the performance of the next generation of particle accelerators. Availability requirements need to be carefully considered during the design phase to achieve challenging objectives in different fields, as e.g. particle physics and material science. For existing and future High-Power facilities, such as ESS (European Spallation Source) and HL-LHC (High-Luminosity LHC), operation with unprecedented beam power requires highly dependable Machine Protection Systems (MPS) to avoid any damage-induced downtime. Due to the high complexity of accelerator systems, finding the optimal balance between equipment safety and accelerator availability is challenging. The MPS architecture, as well as the choice of electronic components, have a large influence on the achievable level of availability. In this thesis novel methods to address the availability of accelerators and their protection systems are presented. Examples of studies related to dependable MPS architectures are given in the thesis, both for Linear accelerators (Linac4, ESS) and circular particle colliders (LHC and HL-LHC). A study of suitable architectures for interlock systems of future availability-critical facilities is presented. Different methods have been applied to assess the anticipated levels of accelerator availability. The thesis presents the prediction of the performance (integrated luminosity for a particle collider) of LHC and future LHC up- grades, based on a Monte Carlo model that allows reproducing a realistic timeline of LHC operation. This model does not only account for the contribution of MPS, but extends to all systems relevant for LHC operation. Results are extrapolated to LHC run 2, run 3 and HL-LHC to derive individual system requirements, based on the target integrated luminosity. (author)

  19. Improving Chronic Disease in the Caribbean through Evidence-based Behavioral and Social In

    Science.gov (United States)

    The Office for Behavioral and Social Sciences Research and the NCI’s Center for Global Health held a workshop entitled “Improving Chronic Disease in the Caribbean through Evidence-based Behavioral and Social Interventions”, which took place in Bridgetown, Barbados from July 21 to 24, 2015. The objectives of the workshop were to encourage the generation of research to more rapidly accelerate chronic disease prevention and management.

  20. A Novel Permanent Magnetic Angular Acceleration Sensor

    Directory of Open Access Journals (Sweden)

    Hao Zhao

    2015-07-01

    Full Text Available Angular acceleration is an important parameter for status monitoring and fault diagnosis of rotary machinery. Therefore, we developed a novel permanent magnetic angular acceleration sensor, which is without rotation angle limitations and could directly measure the instantaneous angular acceleration of the rotating system. The sensor rotor only needs to be coaxially connected with the rotating system, which enables convenient sensor installation. For the cup structure of the sensor rotor, it has a relatively small rotational inertia. Due to the unique mechanical structure of the sensor, the output signal of the sensor can be directed without a slip ring, which avoids signal weakening effect. In this paper, the operating principle of the sensor is described, and simulated using finite element method. The sensitivity of the sensor is calibrated by torsional pendulum and angle sensor, yielding an experimental result of about 0.88 mV/(rad·s−2. Finally, the angular acceleration of the actual rotating system has been tested, using both a single-phase asynchronous motor and a step motor. Experimental result confirms the operating principle of the sensor and indicates that the sensor has good practicability.

  1. Hamiltonian systems in accelerator physics

    International Nuclear Information System (INIS)

    Laslett, L.J.

    1985-06-01

    General features of the design of annular particle accelerators or storage rings are outlined and the Hamiltonian character of individual-ion motion is indicated. Examples of phase plots are presented, for the motion in one spatial degree of freedom, of an ion subject to a periodic nonlinear focusing force. A canonical transformation describing coupled nonlinear motion also is given, and alternative types of graphical display are suggested for the investigation of long-term stability in such cases. 7 figs

  2. An improved 8 GeV beam transport system for the Fermi National Accelerator Laboratory

    International Nuclear Information System (INIS)

    Syphers, M.J.

    1987-06-01

    A new 8 GeV beam transport system between the Booster and Main Ring synchrotrons at the Fermi National Accelerator Laboratory is presented. The system was developed in an effort to improve the transverse phase space area occupied by the proton beam upon injection into the Main Ring accelerator. Problems with the original system are described and general methods of beamline design are formulated. Errors in the transverse properties of a beamline at the injection point of the second synchrotron and their effects on the region in transverse phase space occupied by a beam of particles are discussed. Results from the commissioning phase of the project are presented as well as measurements of the degree of phase space dilution generated by the transfer of 8 GeV protons from the Booster synchrotron to the Main Ring synchrotron

  3. RF Phase Scan for Beam Energy Measurement of KOMAC DTL

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hansung; Kwon, Hyeokjung; Kim, Seonggu; Lee, Seokgeun; Cho, Yongsub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The energy gain through the drift tube linac is a function of the synchronous phase, therefore, the output beam energy from DTL can be affected by the RF phase setting in low-level RF (LLRF) system. The DTL at Korea Multi-purpose Accelerator Complex (KOMAC) consists of 11 tanks and the RF phase setting in each tank should be matched for synchronous acceleration in successive tanks. That means a proper setting of RF phase in each DTL tank is critical for efficient and loss-free operation. The matching RF phase can be determined based on the output energy measurement from the DTL tank. The beam energy can be measured by several methods. For example, we can use a bending magnet to determine the beam energy because the higher momentum of beam means the less deflection angle in the fixed magnetic field. By measuring the range of proton beam through a material with known stopping power also can be utilized to determine the beam energy. We used a well-known time-of-flight method to determine the output beam energy from the DTL tank by measuring beam phase with a beam position monitor (BPM). Based on the energy measurement results, proper RF operating point could be obtained. We performed a RF phase scan to determine the output beam energy from KOMAC DTL by using a time-of-flight method and to set RF operating point precisely. The measured beam energy was compared with a beam dynamics simulation and showed a good agreement. RF phase setting is critical issue for the efficient operation of the proton accelerator, we have a plan to implement and integrate the RF phase measurement system into an accelerator control system for future need.

  4. Advances of dense plasma physics with particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, D.H.H.; Blazevic, A.; Rosmej, O.N.; Spiller, P.; Tahir, N.A.; Weyrich, K. [Gesellschaft fur Schwerionenforschung, GSI-Darmstadt, Plasmaphysik, Darmstadt (Germany); Hoffmann, D.H.H.; Dafni, T.; Kuster, M.; Roth, M.; Udrea, S.; Varentsov, D. [DarmstadtTechnische Univ., Institut fur Kernphysik (Germany); Jacoby, J. [Frankfurt Univ., Institut fur Angewandte Physik (Germany); Zioutas, K. [European Organization for Nuclear Research (CERN), Geneve (Switzerland); Patras Univ., Dept. of Physics (Greece); Sharkov, B.Y. [Institut for Theoretical and Experimental Physics ITEP, Moscow (Russian Federation)

    2006-06-15

    High intensity particle beams from accelerators induce high energy density states in bulk matter. The SIS-18 heavy ion synchrotron at GSI (Darmstadt, Germany) now routinely delivers intense Uranium beams that deposit about 1 kJ/g of specific energy in solid matter, e.g. solid lead. Due to the specific nature of the ion-matter interaction a volume of matter is heated uniformly with low gradients of temperature and pressure in the initial phase, depending on the pulse structure of the beam with respect to space and time. The new accelerator complex FAIR (Facility for Antiproton and ion Research) at GSI as well as beams from the CERN large hadron collider (LHC) will vastly extend the accessible parameter range for high energy density states. One special piece of accelerator equipment a superconducting high field dipole magnet, developed for the LHC at CERN is now serving as a key instrument to diagnose the dense plasma of the sun interior plasma, thus providing an extremely interesting combination of accelerator physics, plasma physics and particle physics. (authors)

  5. Advances of dense plasma physics with particle accelerators

    International Nuclear Information System (INIS)

    Hoffmann, D.H.H.; Blazevic, A.; Rosmej, O.N.; Spiller, P.; Tahir, N.A.; Weyrich, K.; Hoffmann, D.H.H.; Dafni, T.; Kuster, M.; Roth, M.; Udrea, S.; Varentsov, D.; Jacoby, J.; Zioutas, K.; Sharkov, B.Y.

    2006-01-01

    High intensity particle beams from accelerators induce high energy density states in bulk matter. The SIS-18 heavy ion synchrotron at GSI (Darmstadt, Germany) now routinely delivers intense Uranium beams that deposit about 1 kJ/g of specific energy in solid matter, e.g. solid lead. Due to the specific nature of the ion-matter interaction a volume of matter is heated uniformly with low gradients of temperature and pressure in the initial phase, depending on the pulse structure of the beam with respect to space and time. The new accelerator complex FAIR (Facility for Antiproton and ion Research) at GSI as well as beams from the CERN large hadron collider (LHC) will vastly extend the accessible parameter range for high energy density states. One special piece of accelerator equipment a superconducting high field dipole magnet, developed for the LHC at CERN is now serving as a key instrument to diagnose the dense plasma of the sun interior plasma, thus providing an extremely interesting combination of accelerator physics, plasma physics and particle physics. (authors)

  6. Self-accelerated brane Universe with warped extra dimension

    CERN Document Server

    Gorbunov, D S

    2008-01-01

    We propose a cosmological model which exhibits the phenomenon of self-acceleration: the Universe is attracted to the phase of accelerated expansion at late times even in the absence of the cosmological constant. The self-acceleration is inevitable in the sense that it cannot be neutralized by any negative explicit cosmological constant. The model is formulated in the framework of brane-world theories with a warped extra dimension. The key ingredient of the model is the brane-bulk energy transfer which is carried by bulk vector fields with a sigma-model-like boundary condition on the brane. We explicitly find the 5-dimensional metric corresponding to the late-time de Sitter expansion on the brane; this metric describes an AdS_5 black hole with growing mass. The present value of the Hubble parameter implies the scale of new physics of order 1 TeV, where the proposed model has to be replaced by putative UV-completion. The mechanism leading to the self-acceleration has AdS/CFT interpretation as occurring due to s...

  7. Calculation of beam injection and modes of acceleration for the JINR phasotron

    International Nuclear Information System (INIS)

    Vorozhtsov, S.B.; Dmitrievsky, V.P.

    1981-01-01

    On the basis of computer simulation of particles motion from the injection region up to the final radius of the accelerated proton beam behaviour together with different modes of the JINR high current synchrocyclotron operation is investigated. The THOUR modified computer code is used for calculations. The calculations have been performed with allowance for particle radial-phase motion and particle axial motion and although with beam collective effects. Beam dynamics during first turns of particles has been considered by integrating equations of motion. Tolerances for magnetic field structure in the region of first phase oscillation are obtained. Verifications of time dependences of accelerated voltage amplitude are performed. Time dependences of beam intensity (with and without account for space charge effect) and of mean magnetic field disturbance and the dependence of the separatrice dimension on the orbit radius of the accelerated beam are given. The conclusion is drawn on the correctness of the earlier appreciation of beam intensity equaling 40-45 mkA

  8. Stresses in the foil of an electron accelerator extraction channel

    International Nuclear Information System (INIS)

    Abroyan, M.A.; Makarenko, T.I.; Tokmakov, I.L.

    1983-01-01

    Stresses in the foil of an electron accelerator extraction channel are assessed with account of contributions of thermal expansion and stress concentrations during switchings. Optimization of extraction grid parameters of the electron accelerator extraction channel and choice of foil material for high current electron beam is conducted. It is suggested that an extraction grid with circular cells and Al-Mg foil should be used. A simple formula applicable for design calculations is proposed for evaluation of stress concentration coefficient during phase switchings

  9. Is the brain's inertia for motor movements different for acceleration and deceleration?

    Directory of Open Access Journals (Sweden)

    Bhim M Adhikari

    Full Text Available The brain's ability to synchronize movements with external cues is used daily, yet neuroscience is far from a full understanding of the brain mechanisms that facilitate and set behavioral limits on these sequential performances. This functional magnetic resonance imaging (fMRI study was designed to help understand the neural basis of behavioral performance differences on a synchronizing movement task during increasing (acceleration and decreasing (deceleration metronome rates. In the MRI scanner, subjects were instructed to tap their right index finger on a response box in synchrony to visual cues presented on a display screen. The tapping rate varied either continuously or in discrete steps ranging from 0.5 Hz to 3 Hz. Subjects were able to synchronize better during continuously accelerating rhythms than in continuously or discretely decelerating rhythms. The fMRI data revealed that the precuneus was activated more during continuous deceleration than during acceleration with the hysteresis effect significant at rhythm rates above 1 Hz. From the behavioral data, two performance measures, tapping rate and synchrony index, were derived to further analyze the relative brain activity during acceleration and deceleration of rhythms. Tapping rate was associated with a greater brain activity during deceleration in the cerebellum, superior temporal gyrus and parahippocampal gyrus. Synchrony index was associated with a greater activity during the continuous acceleration phase than during the continuous deceleration or discrete acceleration phases in a distributed network of regions including the prefrontal cortex and precuneus. These results indicate that the brain's inertia for movement is different for acceleration and deceleration, which may have implications in understanding the origin of our perceptual and behavioral limits.

  10. Laser accelerated protons captured and transported by a pulse power solenoid

    OpenAIRE

    Burris-Mog, T.; Harres, K.; Zielbauer, B.; Bagnoud, V.; Herrmannsdoerfer, T.; Roth, M.; Cowan, T. E.; Nürnberg, F.; Busold, S.; Bussmann, M.; Deppert, O.; Hoffmeister, G.; Joost, M.; Sobiella, M.; Tauschwitz, A.

    2011-01-01

    Using a pulse power solenoid, we demonstrate efficient capture of laser accelerated proton beams and the ability to control their large divergence angles and broad energy range. Simulations using measured data for the input parameters give inference into the phase-space and transport efficiencies of the captured proton beams. We conclude with results from a feasibility study of a pulse power compact achromatic gantry concept. Using a scaled target normal sheath acceleration spectrum, we prese...

  11. Profile of bosutinib and its clinical potential in the treatment of chronic myeloid leukemia

    Directory of Open Access Journals (Sweden)

    Keller-von Amsberg G

    2013-03-01

    Full Text Available Gunhild Keller-von Amsberg,1 Steffen Koschmieder21Department of Hematology and Oncology, University Cancer Center Hamburg, University Hospital Hamburg Eppendorf, 2Department of Medicine (Hematology, Oncology, and Stem Cell Transplantation, University Medical Center of Aachen and RWTH Aachen University, Aachen, GermanyAbstract: Bosutinib (SKI-606 is an orally available, once-daily, dual Src and Abl kinase inhibitor with promising clinical potential in first-, second-, and third-line treatment of chronic myeloid leukemia (CML. Bosutinib effectively inhibits wild-type BCR-ABL and most imatinib-resistant BCR-ABL mutations except for V299L and T315I. Low hematologic toxicity is a remarkable characteristic of this novel second-generation tyrosine kinase inhibitor, and this has been ascribed to its minimal activity against the platelet-derived growth factor receptor and KIT. Low-grade, typically self-limiting diarrhea, which usually appears within the first few weeks after treatment initiation, represents the predominant toxicity of bosutinib. Other treatment-associated adverse events are mostly mild to moderate. Bosutinib has been approved by the US Food and Drug Administration for the treatment of chronic, accelerated, or blast phase Philadelphia chromosome-positive CML in adult patients with resistance or intolerance to prior therapy. This review summarizes the main properties of bosutinib and the currently available data on its clinical potential in the treatment of CML.Keywords: bosutinib, chronic myeloid leukemia, BCR-ABL, Src/Abl kinase inhibitor, point mutation, imatinib resistance

  12. Effect of flow conditions on flow accelerated corrosion in pipe bends

    International Nuclear Information System (INIS)

    Mazhar, H.; Ching, C.Y.

    2015-01-01

    Flow Accelerated Corrosion (FAC) in piping systems is a safety and reliability problem in the nuclear industry. In this study, the pipe wall thinning rates and development of surface roughness in pipe bends are compared for single phase and two phase annular flow conditions. The FAC rates were measured using the dissolution of test sections cast from gypsum in water with a Schmidt number of 1280. The change in location and levels of maximum FAC under single phase and two phase flow conditions are examined. The comparison of the relative roughness indicates a higher effect for the surface roughness in single phase flow than in two phase flow. (author)

  13. Proxy reporting in after-death interviews: the use of proxy respondents in retrospective assessment of chronic diseases and symptom burden in the terminal phase of life

    NARCIS (Netherlands)

    Klinkenberg, M.; Smit, J. H.; Deeg, D. J. H.; Willems, D. L.; Onwuteaka-Philipsen, B. D.; van der Wal, G.

    2003-01-01

    This study evaluates the quality of data obtained from after-death interviews with significant others of deceased older persons regarding the prevalence of chronic diseases and symptoms in the terminal phase of life. These data are compared with reports from physicians and earlier self-reports from

  14. LLRF and timing system for the SCSS test accelerator at SPring-8

    Energy Technology Data Exchange (ETDEWEB)

    Otake, Yuji, E-mail: otake@spring8.or.jp [RIKEN, SPring-8 Center, XFEL Research and Development Division, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); JASRI, XFEL Division, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Ohshima, Takashi [RIKEN, SPring-8 Center, XFEL Research and Development Division, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); JASRI, XFEL Division, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Hosoda, Naoyasu [JASRI, XFEL Division, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Maesaka, Hirokazu; Fukui, Toru [RIKEN, SPring-8 Center, XFEL Research and Development Division, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); JASRI, XFEL Division, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Kitamura, Masanobu [Hitachi Zosen Corporation, 7-89, Nanko-kita 1-chome, Suminoe-ku, Osaka 559-8559 (Japan); Shintake, Tsumoru [The Okinawa Institute of Science and Technology Graduate University, Tancha, Onna-Son, Kunigami, Okinawa 904-0495 (Japan)

    2012-12-22

    The 250 MeV SCSS test accelerator as an extreme-ultra violet (EUV) laser source has been built at SPring-8. The accelerator comprises a 500 kV thermionic gun, a velocity bunching system using multi-sub-harmonic bunchers (SHB) in an injector and a magnetic bunch compressor using a chicane of 4 bending magnets, a 5712 MHz main accelerator to accelerate an electron beam up to 250 MeV, and undulators to radiate the EUV laser. These bunch compression processes make short bunched electrons with a 300 A peak current and a 300 fs pulse width. The pulse width and peak current of an electron beam, which strongly affect the pulse width and intensity of the laser light, are mainly decided by the pulse compression ratio of the velocity bunching and the magnetic bunch compressing processes. The compression ratio is also determined due to an energy chirp along the beam bunch generated by an off-crest rf field at the SHB and cavities before the chicane. To constantly keep the beam pulse-width conducted by rf and timing signals, which are temporally controlled within subpicoseconds of the designed value, the low-level rf and timing system of the test accelerator has been developed. The system comprises a very low-noise and temporally stable reference signal source, in-phase and quadrature (IQ) modulators and demodulators, as well as VME type 12 bits analog-to-digital and digital-to-analog converter modules to manipulate an rf phase and amplitude by IQ functions for the cavity. We achieved that the SSB noise of the 5712 MHz reference signal source was less than -120 dBc/Hz at 1 kHz offset from the reference frequency; the phase setting and detecting resolution of the IQ-modulators and demodulators were within +/-0.5 Degree-Sign at 5712 MHz. A master trigger VME module and a trigger delay VME module were also developed to activate the components of the test accelerator. The time jitter of the delay module was less than 0.7 ps, sufficient for our present requirement. As a result, a

  15. Chronic hepatitis B virus infection in Asian countries.

    Science.gov (United States)

    Merican, I; Guan, R; Amarapuka, D; Alexander, M J; Chutaputti, A; Chien, R N; Hasnian, S S; Leung, N; Lesmana, L; Phiet, P H; Sjalfoellah Noer, H M; Sollano, J; Sun, H S; Xu, D Z

    2000-12-01

    Of the estimated 50 million new cases of hepatitis B virus (HBV) infection diagnosed annually, 5-10% of adults and up to 90% of infants will become chronically infected, 75% of these in Asia where hepatitis B is the leading cause of chronic hepatitis, cirrhosis and hepatocellular carcinoma (HCC). In Indonesia, 4.6% of the population was positive for HBsAg in 1994 and of these, 21% were positive for HBeAg and 73% for anti-HBe; 44% and 45% of Indonesian patients with cirrhosis and HCC, respectively, were HBsAg positive. In the Philippines, there appear to be two types of age-specific HBsAg prevalence, suggesting different modes of transmission. In Thailand, 8-10% of males and 6-8% of females are HBsAg positive, with HBsAg also found in 30% of patients with cirrhosis and 50-75% of those with HCC. In Taiwan, 75-80% of patients with chronic liver disease are HBsAg positive, and HBsAg is found in 34% and 72% of patients with cirrhosis and HCC, respectively. In China, 73% of patients with chronic hepatitis and 78% and 71% of those with cirrhosis and HCC, respectively, are HBsAg positive. In Singapore, the prevalence of HBsAg has dropped since the introduction of HBV vaccination and the HBsAg seroprevalence of unvaccinated individuals over 5 years of age is 4.5%. In Malaysia, 5.24% of healthy volunteers, with a mean age of 34 years, were positive for HBsAg in 1997. In the highly endemic countries in Asia, the majority of infections are contracted postnatally or perinatally. Three phases of chronic HBV infection are recognized: phase 1 patients are HBeAg positive with high levels of virus in the serum and minimal hepatic inflammation; phase 2 patients have intermittent or continuous hepatitis of varying degrees of severity; phase 3 is the inactive phase during which viral concentrations are low and there is minimal inflammatory activity in the liver. In general, patients who clear HBeAg have a better prognosis than patients who remain HBeAg-positive for prolonged periods of

  16. Particle beam digital phase control system for COSY

    International Nuclear Information System (INIS)

    Schnase, A.

    1994-02-01

    Particle accelerators require that the orbit of the charged particles in the vacuum chamber is controlled to fulfil narrow limits. This is done by magnetic deflection systems and exactly adjusted rf-acceleration. Up to now the necessary control-functions were realised with analogue parts. This work describes a digital phase control system that works in real time and is used with the proton accelerator COSY. The physical design of the accelerator sets the accuracy-specifications of the revolution frequency (<1 Hz in the whole range from 400 kHz to 1.6 MHz), the phase-difference (<0.01 ), the signal-to-noise-ratio (<-60 dBc) and the update rate (<1 μs) of the parameters. In a typical operation the beam is first bunched and synchronised to the reference oscillator. After that the beam influences the rf-system with the help of charge detectors and now the rf-systems will be synchronised with the bunched beam. This control-loop is modelled and simulated with PSPICE. (orig.)

  17. Nuclear phase-out in Switzerland. Rationality first

    International Nuclear Information System (INIS)

    Leidinger, Tobias

    2017-01-01

    Just a few months ago, the Swiss voters have rejected the initiative of the Green Party to accelerate the nuclear phase-out in Switzerland with an impressive majority. Once again, it becomes clear that in Switzerland on issues of energy policy rationality and not ideology is leading. With their vote against an accelerated nuclear phase-out, the Swiss citizens underlined that they have no sympathy for radical, ideologically proposals for solutions, which on closer inspection are expensive, risky and immature. The majority has understood that the extensive expansion of renewable energies and power grids is burdened with numerous risks and uncertainties.

  18. [The impact of Glivec related side effects on daily life in Chinese patients with chronic myeloid leukemia in the chronic phase].

    Science.gov (United States)

    Yu, L; Wang, H B; Huang, X J; Jiang, Q

    2016-07-01

    To explore the impact of Glivec related side effects on daily life in Chinese patients with chronic myeloid leukemia (CML) in the chronic phase (CP). From May to November in 2014, anonymous questionnaires were distributed to adult CML patients who were receiving tyrosine kinase inhibitors (TKI) treatment in China. The impact of TKI related side effects on daily life were assessed by the score of 1 (no impact) to 5 (high impact) from patient self- report. Data from 548 respondents in the CP on Glivec were collected. 303(55%) cases were male with the median age of 40 years (range, 18 to 88 years). 437 (80% ) cases started Glivec treatment within one year after diagnosis with a median treatment duration of 3 years (range, effects were edema (n=278, 51% ), fatigue (n=218, 40% ), gastrointestinal disorders (n=190, 35%), muscle cramps (n=118, 22%), skin color changes (n=118, 22%), weight gain (n=71, 13%), rash (n=60, 11%), hepatic function abnormality (n=55, 10%), and cytopenia (n=38, 7%). Among the 548 respondents, the mean score of Glivec-related side effects on daily life was 2.4±1.2. There was no negative impact of Glivec related side effects on daily life in 161(29%) respondents. 295 (54% ) and 92 (17% ) respondents reported slightly or moderately (2- 3 score) and significantly decreased (4-5 score) daily life, respectively. Multivariate analysis showed that Glivec treatment duration effects including fatigue (OR=2.9, 95% CI 2.1-4.1;Pnegative effect on daily life. Daily life was impaired seriously in a minority of Chinese CML patients who received Glivec, especially in the first 4 years of treatment. Fatigue, edema, gastrointestinal disorders, rash and hepatic function abnormality were side effects associated with negative impact on patients' daily life.

  19. Home-based nerve stimulation to enhance effects of motor training in patients in the chronic phase after stroke: a proof-of-principle study.

    Science.gov (United States)

    Dos Santos-Fontes, Renata Laurenti; Ferreiro de Andrade, Karina Nocelo; Sterr, Annette; Conforto, Adriana Bastos

    2013-01-01

    Somatosensory stimulation in the form of repetitive peripheral nerve stimulation (RPSS) is a promising strategy to improve motor function of the upper limb in chronic stroke. Home-based RPSS may be an alternative to hospital-based RPSS. To investigate the feasibility and safety of an innovative program of home-based RPSS combined with motor training and to collect preliminary data on the efficacy of this program to enhance hand motor function in patients in the chronic phase after stroke. Twenty patients were randomized to either active or sham RPSS associated with daily motor training performed at home over 4 consecutive weeks. All the patients were able to perform tasks of the Jebsen-Taylor Test (JTT). The primary outcome measures were feasibility, evaluated by self-reported compliance with the intervention, and safety (adverse events). Secondary outcomes comprised improvements in hand function in the JTT after end of treatment and after a 4-month follow-up period. There were no relevant adverse events. Compliance with RPSS and motor training was significantly greater in the active group than in the sham group. Upper extremity performance improved significantly more in the active group compared with the sham group at the end of treatment. This difference remained significant 4 months later, even when differences in compliance with motor training were considered. Home-based active RPSS associated with motor training was feasible, was safe, and led to long-lasting enhancement of paretic arm performance in the chronic phase after stroke for those who can perform the JTT. These results point to the need for an efficacy trial.

  20. ECOLE POLYTECHNIQUE: Acceleration by plasma beat waves

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    An experiment by a multi-disciplinary team including laser, plasma, accelerator and particle detector specialists at the École Polytechnique, Palaiseau, France, has confirmed the principle of particle acceleration by the 'beating' of laser waves. The first accelerated electrons were detected in May 1994, just after the apparatus had been completely assembled, during the subsequent set of experiments in July, and again in January. In the continual quest for new acceleration methods, such ideas had been proposed for several decades, but it was only about ten years ago that experimental verification of these effects began. In existing accelerators using radiofrequency cavities the electric field is limited to some hundred megavolts per metre, beyond which breakdowns occur. The joint use of power lasers and plasmas, however, should make it possible to generate fields very much greater than a GV/m. The light wave fulfils the same purpose as radiofrequency and the material medium required to couple the electromagnetic energy to the particle beam is provided by the plasma which - already fully ionized - is not destroyed by a breakdown. In the wave-beating method, proposed in 1979 by Dawson and Tajima, two laser waves of adjacent frequencies are transmitted and produce 'beats'. If the frequency of these is equal to the natural oscillation frequency of the plasma electrons, there is resonant energy transfer. The resultant longitudinal electric field is propagated at slightly below the speed of light and may be used to accelerate particles injected into the plasma in the right phase

  1. Application of radiofrequency superconductivity to accelerators for high-current ion beams

    International Nuclear Information System (INIS)

    Delayen, J.R.; Bohn, C.L.; Kennedy, W.L.; Roche, C.T.; Sagalovsky, L.

    1992-01-01

    A development program is underway to apply rf superconductivity to the design of continuous-wave (cw) linear accelerators for high-current, high-brightness ion beam. During the last few years, considerable progress has been made both experimentally and theoretically toward this application. Recent tests of niobium resonators for ion acceleration have yielded average accelerating gradients as high as 18 MV/m. In an experiment with a radio-frequency quadrupole geometry, niobium was found to sustain cw peak surface electric fields as high as 128 MV/m over large (10 cm) surface areas. Theoretical studies of beam halo, cumulative beam breakup and alternating-phase focusing have also yielded important results. This paper su-summarizes the recent progress and identifies current and future work in the areas of superconducting accelerator technology for high-current ion beams

  2. The acceleration and propagation of energetic particles in turbulent cosmic plasmas

    International Nuclear Information System (INIS)

    Achterberg, A.

    1981-01-01

    This thesis concentrates on the acceleration and propagation of energetic particles in turbulent cosmic plasmas. The stochastic acceleration of relativistic electrons by long-wavelength weak magnetohydrodynamic turbulence is considered and a model is discussed that allows the determination of both the electron energy spectrum and the wavenumber spectrum of the magnetohydrodynamic turbulence in a consistent way. The question of second phase acceleration in large solar flares and the precise form of the force exerted on the background plasma when Alfven waves are generated by fast particles are considered. The energy balance in the shock wave acceleration, the propagation of energetic particles in a high β plasma (β>10 2 ) and sheared flow as a possible source of plasma turbulence for a magnetized plasma with field-aligned flow, are discussed. (Auth./C.F.)

  3. Plasma accelerators

    International Nuclear Information System (INIS)

    Bingham, R.; Angelis, U. de; Johnston, T.W.

    1991-01-01

    Recently attention has focused on charged particle acceleration in a plasma by a fast, large amplitude, longitudinal electron plasma wave. The plasma beat wave and plasma wakefield accelerators are two efficient ways of producing ultra-high accelerating gradients. Starting with the plasma beat wave accelerator (PBWA) and laser wakefield accelerator (LWFA) schemes and the plasma wakefield accelerator (PWFA) steady progress has been made in theory, simulations and experiments. Computations are presented for the study of LWFA. (author)

  4. Accelerated Fractional Ventilation Imaging with Hyperpolarized Gas MRI

    Science.gov (United States)

    Emami, Kiarash; Xu, Yinan; Hamedani, Hooman; Profka, Harrilla; Kadlecek, Stephen; Xin, Yi; Ishii, Masaru; Rizi, Rahim R.

    2013-01-01

    PURPOSE To investigate the utility of accelerated imaging to enhance multi-breath fractional ventilation (r) measurement accuracy using HP gas MRI. Undersampling shortens the breath-hold time, thereby reducing the O2-induced signal decay and allows subjects to maintain a more physiologically relevant breathing pattern. Additionally it may improve r estimation accuracy by reducing RF destruction of HP gas. METHODS Image acceleration was achieved by using an 8-channel phased array coil. Undersampled image acquisition was simulated in a series of ventilation images and images were reconstructed for various matrix sizes (48–128) using GRAPPA. Parallel accelerated r imaging was also performed on five mechanically ventilated pigs. RESULTS Optimal acceleration factor was fairly invariable (2.0–2.2×) over the range of simulated resolutions. Estimation accuracy progressively improved with higher resolutions (39–51% error reduction). In vivo r values were not significantly different between the two methods: 0.27±0.09, 0.35±0.06, 0.40±0.04 (standard) versus 0.23±0.05, 0.34±0.03, 0.37±0.02 (accelerated); for anterior, medial and posterior slices, respectively, whereas the corresponding vertical r gradients were significant (P fractional ventilation measurement with HP gas MRI. PMID:23400938

  5. Conceptual study of high power proton linac for accelerator driven subcritical nuclear power system

    CERN Document Server

    Yu Qi; Ouyang Hua Fu; Xu Tao Guang

    2001-01-01

    As a prior option of the next generation of energy source, the accelerator driven subcritical nuclear power system (ADS) can use efficiently the uranium and thorium resource, transmute the high-level long-lived radioactive wastes and raise nuclear safety. The ADS accelerator should provide the proton beam with tens megawatts. The superconducting linac is a good selection of ADS accelerator because of its high efficiency and low beam loss rate. The ADS accelerator presented by the consists of a 5 MeV radio-frequency quadrupole, a 100 MeV independently phased superconducting cavity linac and a 1 GeV elliptical superconducting cavity linac. The accelerating structures and main parameters are determined and the research and development plan is considered

  6. Once-Monthly Continuous Erythropoietin Receptor Activator (C.E.R.A.) in Patients with Hemodialysis-Dependent Chronic Kidney Disease: Pooled Data from Phase III Trials.

    Science.gov (United States)

    Locatelli, Francesco; Choukroun, Gabriel; Truman, Matt; Wiggenhauser, Alfons; Fliser, Danilo

    2016-04-01

    Erythropoiesis-stimulating agents and iron are commonly used in patients with chronic kidney disease with the aim of correcting anemia and maintaining stable hemoglobin levels. We analyzed pooled data from 13 studies with similar designs included in the Umbrella Continuous Erythropoietin Receptor Activator (C.E.R.A.) program to investigate the effects of continuous erythropoiesis receptor activator in clinically relevant subgroups of patients with chronic kidney disease and to determine whether the efficacy and safety outcomes demonstrated in the overall chronic kidney disease population are maintained in specific subgroups. Data from 13 Phase III trials set up with similar design were retrospectively pooled for this analysis. Patients with chronic kidney disease who had previously been receiving epoetin or darbepoetin were switched to continuous erythropoiesis receptor activator once-monthly after a 4- to 8-week screening period. Patients entered a 16-week continuous erythropoiesis receptor activator dose-titration period followed by an 8-week evaluation period. In total, 2060 patients were included in the analysis. Subgroups were defined based on: hemoglobin target range [lower (10.0-12.0 g/dL)/upper (10.5-13.0 g/dL)], gender (female/male), age (Basel, Switzerland.

  7. Auroral particle acceleration by Alfvén waves and ionospheric feedback

    Science.gov (United States)

    Lysak, R. L.; Song, Y.

    2003-12-01

    Recent observations, particularly by Polar and FAST, have indicated that Alfvén waves can directly accelerate auroral electrons. A model for this interaction has been developed that can describe the linear modification of the Alfvén wave profile by the kinetic effects of electrons, including acceleration and heating of the electron population. While many of the heated electrons are accelerated upward into the magnetosphere by the mirror force, a significant fraction of the input Poynting flux due to Alfvén waves can be converted into precipitating electron energy flux. An important aspect of this particle precipitation is that the hot electrons do not arrive at the ionosphere in phase with the field-aligned current, which at ionospheric altitudes is largely carried by cold electrons. This phase shift has direct implications for models of ionospheric feedback that usually assume that the precipitating flux is in phase with the field-aligned current. The effects of quasi-static electric fields can be included in the model, which will introduce new particle populations such as the effects of secondary electrons of ionospheric origin that are reflected by the parallel potential drop. The possible role of Alfvén waves trapped in the ionospheric resonator in creating small-scale auroral structures through feedback and nonlinear interactions will be discussed.

  8. Accelerated radial Fourier-velocity encoding using compressed sensing

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, Fabian; Han, Dietbert [Wuerzburg Univ. (Germany). Inst. of Radiology; Wech, Tobias; Koestler, Herbert [Wuerzburg Univ. (Germany). Inst. of Radiology; Wuerzburg Univ. (Germany). Comprehensive Heart Failure Center (CHFC)

    2014-10-01

    Purpose:Phase Contrast Magnetic Resonance Imaging (MRI) is a tool for non-invasive determination of flow velocities inside blood vessels. Because Phase Contrast MRI only measures a single mean velocity per voxel, it is only applicable to vessels significantly larger than the voxel size. In contrast, Fourier Velocity Encoding measures the entire velocity distribution inside a voxel, but requires a much longer acquisition time. For accurate diagnosis of stenosis in vessels on the scale of spatial resolution, it is important to know the velocity distribution of a voxel. Our aim was to determine velocity distributions with accelerated Fourier Velocity Encoding in an acquisition time required for a conventional Phase Contrast image. Materials and Methods:We imaged the femoral artery of healthy volunteers with ECG - triggered, radial CINE acquisition. Data acquisition was accelerated by undersampling, while missing data were reconstructed by Compressed Sensing. Velocity spectra of the vessel were evaluated by high resolution Phase Contrast images and compared to spectra from fully sampled and undersampled Fourier Velocity Encoding. By means of undersampling, it was possible to reduce the scan time for Fourier Velocity Encoding to the duration required for a conventional Phase Contrast image. Results:Acquisition time for a fully sampled data set with 12 different Velocity Encodings was 40 min. By applying a 12.6 - fold retrospective undersampling, a data set was generated equal to 3:10 min acquisition time, which is similar to a conventional Phase Contrast measurement. Velocity spectra from fully sampled and undersampled Fourier Velocity Encoded images are in good agreement and show the same maximum velocities as compared to velocity maps from Phase Contrast measurements. Conclusion: Compressed Sensing proved to reliably reconstruct Fourier Velocity Encoded data. Our results indicate that Fourier Velocity Encoding allows an accurate determination of the velocity

  9. Accelerated radial Fourier-velocity encoding using compressed sensing

    International Nuclear Information System (INIS)

    Hilbert, Fabian; Han, Dietbert

    2014-01-01

    Purpose:Phase Contrast Magnetic Resonance Imaging (MRI) is a tool for non-invasive determination of flow velocities inside blood vessels. Because Phase Contrast MRI only measures a single mean velocity per voxel, it is only applicable to vessels significantly larger than the voxel size. In contrast, Fourier Velocity Encoding measures the entire velocity distribution inside a voxel, but requires a much longer acquisition time. For accurate diagnosis of stenosis in vessels on the scale of spatial resolution, it is important to know the velocity distribution of a voxel. Our aim was to determine velocity distributions with accelerated Fourier Velocity Encoding in an acquisition time required for a conventional Phase Contrast image. Materials and Methods:We imaged the femoral artery of healthy volunteers with ECG - triggered, radial CINE acquisition. Data acquisition was accelerated by undersampling, while missing data were reconstructed by Compressed Sensing. Velocity spectra of the vessel were evaluated by high resolution Phase Contrast images and compared to spectra from fully sampled and undersampled Fourier Velocity Encoding. By means of undersampling, it was possible to reduce the scan time for Fourier Velocity Encoding to the duration required for a conventional Phase Contrast image. Results:Acquisition time for a fully sampled data set with 12 different Velocity Encodings was 40 min. By applying a 12.6 - fold retrospective undersampling, a data set was generated equal to 3:10 min acquisition time, which is similar to a conventional Phase Contrast measurement. Velocity spectra from fully sampled and undersampled Fourier Velocity Encoded images are in good agreement and show the same maximum velocities as compared to velocity maps from Phase Contrast measurements. Conclusion: Compressed Sensing proved to reliably reconstruct Fourier Velocity Encoded data. Our results indicate that Fourier Velocity Encoding allows an accurate determination of the velocity

  10. Accelerated radial Fourier-velocity encoding using compressed sensing.

    Science.gov (United States)

    Hilbert, Fabian; Wech, Tobias; Hahn, Dietbert; Köstler, Herbert

    2014-09-01

    Phase Contrast Magnetic Resonance Imaging (MRI) is a tool for non-invasive determination of flow velocities inside blood vessels. Because Phase Contrast MRI only measures a single mean velocity per voxel, it is only applicable to vessels significantly larger than the voxel size. In contrast, Fourier Velocity Encoding measures the entire velocity distribution inside a voxel, but requires a much longer acquisition time. For accurate diagnosis of stenosis in vessels on the scale of spatial resolution, it is important to know the velocity distribution of a voxel. Our aim was to determine velocity distributions with accelerated Fourier Velocity Encoding in an acquisition time required for a conventional Phase Contrast image. We imaged the femoral artery of healthy volunteers with ECG-triggered, radial CINE acquisition. Data acquisition was accelerated by undersampling, while missing data were reconstructed by Compressed Sensing. Velocity spectra of the vessel were evaluated by high resolution Phase Contrast images and compared to spectra from fully sampled and undersampled Fourier Velocity Encoding. By means of undersampling, it was possible to reduce the scan time for Fourier Velocity Encoding to the duration required for a conventional Phase Contrast image. Acquisition time for a fully sampled data set with 12 different Velocity Encodings was 40 min. By applying a 12.6-fold retrospective undersampling, a data set was generated equal to 3:10 min acquisition time, which is similar to a conventional Phase Contrast measurement. Velocity spectra from fully sampled and undersampled Fourier Velocity Encoded images are in good agreement and show the same maximum velocities as compared to velocity maps from Phase Contrast measurements. Compressed Sensing proved to reliably reconstruct Fourier Velocity Encoded data. Our results indicate that Fourier Velocity Encoding allows an accurate determination of the velocity distribution in vessels in the order of the voxel size. Thus

  11. High current electron beam acceleration in dielectric-filled RF cavities

    International Nuclear Information System (INIS)

    Faehl, R.J.; Keinigs, R.K.

    1996-01-01

    The acceleration of charged particles in radio frequency (RF) cavities is a widely used mode in high energy accelerators. Advantages include very high accelerating gradients and very stable phase control. A traditional limitation for such acceleration has been their use for intense, high current beam generation. This constraint arises from the inability to store a large amount of electromagnetic energy in the cavity and from loading effects of the beam on the cavity. The authors have studied a simple modification to transcend these limitations. Following Humphries and Huang, they have conducted analytic and numerical investigations of RF accelerator cavities in which a high dielectric constant material, such as water, replaces most of the cavity volume. This raises the stored energy in a cavity of given dimensions by a factor var-epsilon/var-epsilon 0 . For a water fill, var-epsilon/var-epsilon 0 ∼ 80, depending on the frequency. This introduction of high dielectric constant material into the cavity reduces the resonant frequencies by a factor of (var-epsilon/var-epsilon 0 ) 1/2 . This reduced operating frequency mans that existing high efficiency power supplies, at lower frequencies, can be used for an accelerator

  12. Space lattice focusing on the way to extremely low accelerated beam divergence

    CERN Document Server

    Kushin, V V

    1999-01-01

    It is widely known the multiple channel acceleration is the most adequate way to save initial beam parameters due to the possibility of decreasing Coulomb forces in intensive input beams. To keep beam initial emittance and divergence for high enough specific value of the injection ion beam during acceleration the input beam should be split on multiple beams and every the micro beam must be screened from each other as much as possible. On the other hand, it is very much desirable to keep the total macro beam rather compact transversally and try to accelerate all the micro beams within the same accelerator structure at the same RF field. Attempts to use conventional quadruple focusing channels both RF and electrostatic for multiple beam acceleration usually lead to extremely complicate and bulky construction of the structure. We suppose multiple beam linac channels with alternating phase focusing (APF) as more adequate for the purpose while they are limited by less values of beam capture into acceleration proce...

  13. Modeling high-Power Accelerators Reliability-SNS LINAC (SNS-ORNL); MAX LINAC (MYRRHA)

    International Nuclear Information System (INIS)

    Pitigoi, A. E.; Fernandez Ramos, P.

    2013-01-01

    Improving reliability has recently become a very important objective in the field of particle accelerators. The particle accelerators in operation are constantly undergoing modifications, and improvements are implemented using new technologies, more reliable components or redundant schemes (to obtain more reliability, strength, more power, etc.) A reliability model of SNS (Spallation Neutron Source) LINAC has been developed within MAX project and analysis of the accelerator systems reliability has been performed within the MAX project, using the Risk Spectrum reliability analysis software. The analysis results have been evaluated by comparison with the SNS operational data. Results and conclusions are presented in this paper, oriented to identify design weaknesses and provide recommendations for improving reliability of MYRRHA linear accelerator. The SNS reliability model developed for the MAX preliminary design phase indicates possible avenues for further investigation that could be needed to improve the reliability of the high-power accelerators, in view of the future reliability targets of ADS accelerators.

  14. Cervical muscle dysfunction in chronic whiplash-associated disorder grade 2: the relevance of the trauma.

    Science.gov (United States)

    Nederhand, Marc J; Hermens, Hermie J; IJzerman, Maarten J; Turk, Dennis C; Zilvold, Gerrit

    2002-05-15

    Surface electromyography measurements of the upper trapezius muscles were performed in patients with a chronic whiplash-associated disorder Grade 2 and those with nonspecific neck pain. To determine the etiologic relation between acceleration-deceleration trauma and the presence of cervical muscle dysfunction in the chronic stage of whiplash-associated disorder. From a biopsychosocial perspective, the acceleration-deceleration trauma in patients with whiplash-associated disorder is not regarded as a cause of chronicity of neck pain, but rather as a risk factor triggering response systems that contribute to the maintenance of neck pain. One of the contributing factors is dysfunction of the cervical muscles. Considering the limited etiologic significance of the trauma, it is hypothesized that in patients with neck pain, there are no differences in muscle activation patterns between those with and those without a history of an acceleration-deceleration trauma. Muscle activation patterns, expressed in normalized smooth rectified electromyography levels of the upper trapezius muscles, in patients with whiplash-associated disorder Grade 2 were compared with those of patients with nonspecific neck pain. The outcome parameters were the mean level of muscle activity before and after a physical exercise, the muscle reactivity in response to the exercise, and the time-dependent behavior of muscle activity after the exercise. There were no statistical significant differences in any of the outcome parameters between patients with whiplash-associated disorder Grade 2 and those with nonspecific neck pain. There was only a tendency of higher muscle reactivity in patients with whiplash-associated disorder Grade 2. It appears that the cervical muscle dysfunction in patients with chronic whiplash-associated disorder Grade 2 is not related to the specific trauma mechanism. Rather, cervical muscle dysfunction appears to be a general sign in diverse chronic neck pain syndromes.

  15. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1990-12-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation and to treat two particular examples

  16. Analysis of beam feedback loops of RF acceleration system at TARN II

    International Nuclear Information System (INIS)

    Katayama, Takeshi.

    1992-08-01

    Two beam-feedback-loops are prepared for the frequency control of RF acceleration system at cooler-synchrotron TARN II. One is the phase-loop and the other the radial-position-loop. In the present paper, the effects of these loops on the beam dynamics in the synchrotron are studied on the basis of Laplace transformation approach as well as the numerical values for the synchrotron acceleration at TARN II. (author)

  17. On the quasi-monoenergetic electron beam generation in the laser wakefield acceleration

    International Nuclear Information System (INIS)

    Bulanov, S.V.; Tajima, Toshiki

    2005-01-01

    A new phase of laser acceleration research has entered, as signified by the recent reports in Nature 9/30/05 of the generation of quasi-monoenergetic electron beam by laser wakefield acceleration in three experiments. We survey the current status of experiments and offer their theoretical interpretation. We understand why the choice of parameters is of such importance and why the earlier experiments showed energy spectra far from monoenergy. (author)

  18. Pharmacokinetics and pharmacokinetic/pharmacodynamic associations of ofatumumab, a human monoclonal CD20 antibody, in patients with relapsed or refractory chronic lymphocytic leukaemia: a phase 1-2 study

    DEFF Research Database (Denmark)

    Coiffier, Bertrand; Losic, Nedjad; Rønn, Birgitte Biilmann

    2010-01-01

    The purpose of this phase 1-2 study was to investigate the association between the pharmacokinetic properties of ofatumumab, a human monoclonal CD20 antibody, and outcomes in 33 patients with relapsed/refractory chronic lymphocytic leukaemia receiving 4 weekly infusions of ofatumumab. The ofatumu...

  19. Chronic oral infection with major periodontal bacteria Tannerella forsythia modulates systemic atherosclerosis risk factors and inflammatory markers.

    Science.gov (United States)

    Chukkapalli, Sasanka S; Rivera-Kweh, Mercedes F; Velsko, Irina M; Chen, Hao; Zheng, Donghang; Bhattacharyya, Indraneel; Gangula, Pandu R; Lucas, Alexandra R; Kesavalu, Lakshmyya

    2015-04-01

    Tannerella forsythia is a Gram-negative anaerobic organism that inhabits the subgingival cavity and initiates connective tissue destruction and alveolar bone resorption in periodontal disease (PD). PD is a chronic immunoinflammatory disease and has been linked to several systemic diseases including atherosclerosis. This study evaluated the effects of a chronic oral infection with T. forsythia ATCC 43037 on the induction of PD, inflammatory markers and atherosclerosis risk factors in hyperlipidemic ApoE(null) mice. Mice were orally infected for 12 and 24 weeks prior to euthanasia. Bacterial colonization of the oral cavity and bacteremia was confirmed via isolation of genomic DNA from oral plaque and tissues. Oral infection elicited significantly elevated levels of serum IgG and IgM antibodies and alveolar bone resorption compared to control mice. Tannerella forsythia-infected mice had increased serum amyloid A, and significantly reduced serum nitric oxide when compared to controls. Tannerella forsythia chronic infection also significantly increased serum lipoproteins suggesting altered cholesterol metabolism and potential for aortic inflammation. Despite enhanced acute phase reactants and altered lipid profiles, T. forsythia infection was associated with decreased aortic plaque. This study investigates the potential of a known periodontal bacterial pathogen found in atherosclerotic plaque in humans to accelerate atherosclerosis in hyperlipdemic mice. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. FFAGs: Front-end for neutrino factories and medical accelerators

    Science.gov (United States)

    Mori, Yoshiharu

    The idea of Fixed Field Alternating Gradient (FFAG) accelerator was originated by different people and groups in the early 1950s. It was independently introduced by Ohkawa [Ohkawa (1953)], Symon et al. [Symon et al. (1956)], and Kolomensky [Kolomensky and Lebedev (1966)] when the strong Alternate Gradient (AG) focusing and the phase stability schemes were applied to particle acceleration. The first FFAG electron model was developed in the MURA accelerator project led by Kerst and Cole in the late 1950s. Since then, they have fabricated several electron models in the early 1960s [Symon et al. (1956)]. However, the studies did not lead to a single practical FFAG accelerator for the following 50 years. Because of the difficulties of treating non-linear magnetic field and RF acceleration for non-relativistic particles, the proton FFAG, especially, was not accomplished until recently. In 2000, the FFAG concept was revived with the world's first proton FFAG (POP) which was developed at KEK [Aiba (2000); Mori (1999)]. Since then, in many places [Berg (2004); Johnstone et al. (2004); Mori (2011); Ruggiero (2004); Trbojevic (2004)], FFAGs have been developed and constructed...

  1. Cyclotron Acceleration of Relativistic Electrons through Landau Resonance with Obliquely Propagating Whistler Mode Chorus Emissions

    Science.gov (United States)

    Omura, Y.; Hsieh, Y. K.; Foster, J. C.; Erickson, P. J.; Kletzing, C.; Baker, D. N.

    2017-12-01

    A recent test particle simulation of obliquely propagating whistler mode wave-particle interaction [Hsieh and Omura, 2017] shows that the perpendicular wave electric field can play a significant role in trapping and accelerating relativistic electrons through Landau resonance. A further theoretical and numerical investigation verifies that there occurs nonlinear wave trapping of relativistic electrons by the nonlinear Lorentz force of the perpendicular wave magnetic field. An electron moving with a parallel velocity equal to the parallel phase velocity of an obliquely propagating wave basically see a stationary wave phase. Since the electron position is displaced from its gyrocenter by a distance ρ*sin(φ), where ρ is the gyroradius and φ is the gyrophase, the wave phase is modulated with the gyromotion, and the stationary wave fields as seen by the electron are expanded as series of Bessel functions Jn with phase variations n*φ. The J1 components of the wave electric and magnetic fields rotate in the right-hand direction with the gyrofrequency, and they can be in resonance with the electron undergoing the gyromotion, resulting in effective electron acceleration and pitch angle scattering. We have performed a subpacket analysis of chorus waveforms observed by the Van Allen Probes [Foster et al., 2017], and calculated the energy gain by the cyclotron acceleration through Landau resonance. We compare the efficiencies of accelerations by cyclotron and Landau resonances in typical events of rapid electron acceleration observed by the Van Allen Probes.References:[1] Hsieh, Y.-K., and Y. Omura (2017), Nonlinear dynamics of electrons interacting with oblique whistler mode chorus in the magnetosphere, J. Geophys. Res. Space Physics, 122, 675-694, doi:10.1002/2016JA023255.[2] Foster, J. C., P. J. Erickson, Y. Omura, D. N. Baker, C. A. Kletzing, and S. G. Claudepierre (2017), Van Allen Probes observations of prompt MeV radiation belt electron acceleration in nonlinear

  2. On-line monitoring system development for single-phase flow accelerated corrosion

    International Nuclear Information System (INIS)

    Lee, Na Young; Lee, Seung Gi; Ryu, Kyung Ha; Hwang, Il Soon

    2007-01-01

    Aged nuclear piping has been reported to undergo corrosion-induced accelerated failures, often without giving signatures to current inspection campaigns. Therefore, we need diverse sensors which can cover a wide area in an on-line application. We suggest an integrated approach to monitor the flow accelerated corrosion (FAC) susceptible piping. Since FAC is a combined phenomenon, we need to monitor as many parameters as possible and that cover wide area, since we do not know where the FAC occurs. For this purpose, we introduce the wearing rate model which focuses on the electrochemical parameters. Using this model, we can predict the wearing rate and then compare testing results. Through analysis we identified feasibility and then developed electrochemical sensors for high temperature application; we also introduced a mechanical monitoring system which is still under development. To support the validation of the monitored results, we adopted high temperature ultrasonic transducer (UT), which shows good resolution in the testing environment. As such, all the monitored results can be compared in terms of thickness. Our validation tests demonstrated the feasibility of sensors. To support direct thickness measurement for a wide-area, the direct current potential drop (DCPD) method will be researched to integrate into the developed framework

  3. Vascular toxicity of urea, a new "old player" in the pathogenesis of chronic renal failure induced cardiovascular diseases.

    Science.gov (United States)

    Giardino, Ida; D'Apolito, Maria; Brownlee, Michael; Maffione, Angela Bruna; Colia, Anna Laura; Sacco, Michele; Ferrara, Pietro; Pettoello-Mantovani, Massimo

    2017-12-01

    Chronic kidney disease in children is an irreversible process that may lead to end-stage renal disease. The mortality rate in children with end-stage renal disease who receive dialysis increased dramatically in the last decade, and it is significantly higher compared with the general pediatric population. Furthermore, dialysis and transplant patients, who have developed end-stage renal disease during childhood, live respectively far less as compared with age/race-matched populations. Different reports show that cardiovascular disease is the leading cause of death in children with end-stage renal disease and in adults with childhood-onset chronic kidney disease, and that children with chronic kidney disease are in the highest risk group for the development of cardiovascular disease. Urea, which is generated in the liver during catabolism of amino acids and other nitrogenous metabolites, is normally excreted into the urine by the kidneys as rapidly as it is produced. When renal function is impaired, increasing concentrations of blood urea will steadily accumulate. For a long time, urea has been considered to have negligible toxicity. However, the finding that plasma urea is the only significant predictor of aortic plaque area fraction in an animal model of chronic renal failure -accelerated atherosclerosis, suggests that the high levels of urea found in chronic dialysis patients might play an important role in accelerated atherosclerosis in this group of patients. The aim of this review was to provide novel insights into the role played by urea in the pathogenesis of accelerated cardiovascular disease in renal failure.

  4. First muon acceleration using a radio-frequency accelerator

    Directory of Open Access Journals (Sweden)

    S. Bae

    2018-05-01

    Full Text Available Muons have been accelerated by using a radio-frequency accelerator for the first time. Negative muonium atoms (Mu^{-}, which are bound states of positive muons (μ^{+} and two electrons, are generated from μ^{+}’s through the electron capture process in an aluminum degrader. The generated Mu^{-}’s are initially electrostatically accelerated and injected into a radio-frequency quadrupole linac (RFQ. In the RFQ, the Mu^{-}’s are accelerated to 89 keV. The accelerated Mu^{-}’s are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.

  5. Phase space measurements at non-accessible point on the beam path of an accelerator facility

    International Nuclear Information System (INIS)

    Hassan, A.

    2004-01-01

    The optimization of beam lines for particles extracted from accelerator facilities requires the knowledge of beam parameters. A method for the measurement of phase space and beam intensity distribution is represented. This method depends on the setting of quadrupole lenses that allows the imaging of beam profiles at arbitrary positions along the beam path on the same multi-wire proportional chamber, where the intensity distribution can be evaluated. The necessary focusing powers for a certain imaging task are calculated in a thin lens approximation. The corresponding focusing power for thick quadrupole lenses are calculated using the PC transport program. A comparison of the calculated focusing powers for thin and thick lenses reveals deviations at the highest field strengths, due to saturation effect. The position of the beam waist in normal and angular space is directly calculated and visualized. The horizontal and vertical waist positions are found to be rather independent of the beam energy. Extensive calculation was done to study the effect of a reduced aperture on the maximum beam emittances aa x and aa y of the extracted particles. The main result shows that the maximum emittance passing through depends on the waist distant and the diameter of the reduced aperture. (orig.)

  6. Shear induced phase transitions induced in edible fats

    Science.gov (United States)

    Mazzanti, Gianfranco; Welch, Sarah E.; Marangoni, Alejandro G.; Sirota, Eric B.; Idziak, Stefan H. J.

    2003-03-01

    The food industry crystallizes fats under different conditions of temperature and shear to obtain products with desired crystalline phases. Milk fat, palm oil, cocoa butter and chocolate were crystallized from the melt in a temperature controlled Couette cell. Synchrotron x-ray diffraction studies were conducted to examine the role of shear on the phase transitions seen in edible fats. The shear forces on the crystals induced acceleration of the alpha to beta-prime phase transition with increasing shear rate in milk fat and palm oil. The increase was slow at low shear rates and became very strong above 360 s-1. In cocoa butter the acceleration between beta-prime-III and beta-V phase transition increased until a maximum of at 360 s-1, and then decreased, showing competition between enhanced heat transfer and viscous heat generation.

  7. Design of the buncher of travelling-wave linear accelerator

    International Nuclear Information System (INIS)

    Ghasemi, F.; Abbasi Davani, F.; Lamehi Rashti, M.; Shaker, H.

    2011-01-01

    The project of design and construction of linear electron accelerator is being performed by the Ministry of Science, Research and Technology and Institute for Research in Fundamental Sciences (IPM). The aim of the current research is to achieve the knowledge and the technology of manufacturing the components of linear accelerator; one of these components is buncher. In this paper, two types of bunchers are introduced, while the disk-loaded type has been selected to be fabricated. Studying the electrons motion in the field through the aperture of the disks and using the equations of disk-loaded waveguide theory, the dimensions of the desired buncher for this project were obtained. MATLAB software and SUPERFISH code were used in calculations and simulations. The design led to the initial and final phase ranges of 348 degrees and 50 degrees, respectively. The mentioned values for the initial and final phase ranges resulted in a bunching factor of about 7 that is appropriate for this type of the bunchers.

  8. Self focusing in a spatially modulated electrostatic field particle accelerator

    Science.gov (United States)

    Russman, F.; Marini, S.; Peter, E.; de Oliveira, G. I.; Rizzato, F. B.

    2018-02-01

    In the present analysis, we study the action of a three-dimensional (3D) modulated electrostatic wave over a charged particle. Meanwhile, the particle's velocity is smaller than the phase-velocity of the carrier, and the particle could be reflected by the potential or could pass through the potential with no significant change in the longitudinal velocity—and its dynamics could be described by a ponderomotive approximation. Otherwise, the particle is trapped by the potential and it is accelerated towards the speed of light, independently of the initial particle's phase—in this case, the ponderomotive approximation is no longer valid. During the acceleration process, numerical simulations show the particle is focused, simultaneously. These results suggest the accelerator proposed here is promising.

  9. Modeling of inverse Cherenkov laser acceleration with axicon laser-beam focusing

    International Nuclear Information System (INIS)

    Romea, R.D.; Kimura, W.D.

    1990-01-01

    Acceleration of free electrons by the inverse Cherenkov effect using radially polarized laser light focused through an axicon [J. P. Fontana and R. H. Pantell, J. Appl. Phys. 54, 4285 (1983)] has been studied utilizing a Monte Carlo computer simulation and further theoretical analysis. The model includes effects, such as scattering of the electrons by the gas, and diffraction and interference effects of the axicon laser beam, that were not included in the original analysis of Fontana and Pantell. Its accuracy is validated using available experimental data. The model results show that effective acceleration is possible even with the effects of scattering. Sample results are given. The analysis includes examining the issues of axicon focusing, phase errors, energy gain, phase slippage, focusing of the e beam, and emittance growth

  10. Accelerator development

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Because the use of accelerated heavy ions would provide many opportunities for new and important studies in nuclear physics and nuclear chemistry, as well as other disciplines, both the Chemistry and Physics Divisions are supporting the development of a heavy-ion accelerator. The design of greatest current interest includes a tandem accelerator with a terminal voltage of approximately 25 MV injecting into a linear accelerator with rf superconducting resonators. This combined accelerator facility would be capable of accelerating ions of masses ranging over the entire periodic table to an energy corresponding to approximately 10 MeV/nucleon. This approach, as compared to other concepts, has the advantages of lower construction costs, lower operating power, 100 percent duty factor, and high beam quality (good energy resolution, good timing resolution, small beam size, and small beam divergence). The included sections describe the concept of the proposed heavy-ion accelerator, and the development program aiming at: (1) investigation of the individual questions concerning the superconducting accelerating resonators; (2) construction and testing of prototype accelerator systems; and (3) search for economical solutions to engineering problems. (U.S.)

  11. A Framework for a General Purpose Intelligent Control System for Particle Accelerators. Phase II Final Report

    International Nuclear Information System (INIS)

    Westervelt, Robert; Klein, William; Kroupa, Michael; Olsson, Eric; Rothrock, Rick

    1999-01-01

    Vista Control Systems, Inc. has developed a portable system for intelligent accelerator control. The design is general in scope and is thus configurable to a wide range of accelerator facilities and control problems. The control system employs a multi-layer organization in which knowledge-based decision making is used to dynamically configure lower level optimization and control algorithms

  12. Beam dynamics of alternating-phase-focused linac

    CERN Document Server

    Iwata, Y; Kapin, V

    2004-01-01

    A simple method to find an array of synchronous phases for alternating-phase-focused (APF) linacs is presented. The phase array is described with a smooth function having free parameters. With a set of the parameters, a simulation on the beam dynamics was made and distributions of the six-dimensional phase spaces were calculated for each set of the parameters. The parameters were varied, and numbers of the simulations have been performed. An optimum set of the parameters were determined so that the simulations of the beam dynamics yield large acceptances and small emittances of the extracted beams. Since the APF linac can provide both axial and radial stability of beams just with the rf acceleration-field, no additional focusing element inside of drift tubes are necessary. Comparing with conventional linacs having focusing elements, it has advantage in construction and operation costs as well as its acceleration rate. Therefore, the APF linacs would be suited for an injector of medical synchrotrons. A practic...

  13. Accelerator Technology: Geodesy and Alignment for Particle Accelerators

    CERN Document Server

    Missiaen, D

    2013-01-01

    This document is part of Subvolume C 'Accelerators and Colliders' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the the Section '8.9 Geodesy and Alignment for Particle Accelerators' of the Chapter '8 Accelerator Technology' with the content: 8.9 Geodesy and Alignment for Particle Accelerators 8.9.1 Introduction 8.9.2 Reference and Co-ordinate Systems 8.9.3 Definition of the Beam Line on the Accelerator Site 8.9.4 Geodetic Network 8.9.5 Tunnel Preliminary Works 8.9.6 The Alignment References 8.9.7 Alignment of Accelerator Components 8.9.8 Permanent Monitoring and Remote Alignment of Low Beta Quadrupoles 8.9.9 Alignment of Detector Components

  14. Accelerator structure bead pull measurement at SLAC

    CERN Document Server

    Lewandowski, J R; Miller, R H; Wang, J W

    2004-01-01

    Microwave measurement and tuning of accelerator structures are important issues for the current and next generation of high energy physics machines. Application of these measurements both before and after high power processing can reveal information about the structure but may be misinterpreted if measurement conditions are not carefully controlled. For this reason extensive studies to characterize the microwave measurements at have been made at SLAC. For the beadpull a reproducible measurement of less than 1 degree of phase accuracy in total phase drift is needed in order to resolve issues such as phase changes due to structure damage during high power testing. Factors contributing to measurement errors include temperature drift, mechanical vibration, and limitations of measurement equipment such as the network analyzer. Results of this continuing effort will be presented.

  15. Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-01-17

    Dexamethasone loaded poly(lactic-co-glycolic acid) (PLGA) microsphere/PVA hydrogel composites have been investigated as an outer drug-eluting coating for implantable devices such as glucose sensors to counter negative tissue responses to implants. The objective of this study was to develop a discriminatory, accelerated in vitro release testing method for this drug-eluting coating using United States Pharmacopeia (USP) apparatus 4. Polymer degradation and drug release kinetics were investigated under "real-time" and accelerated conditions (i.e. extreme pH, hydro-alcoholic solutions and elevated temperatures). Compared to "real-time" conditions, the initial burst and lag phases were similar using hydro-alcoholic solutions and extreme pH conditions, while the secondary apparent zero-order release phase was slightly accelerated. Elevated temperatures resulted in a significant acceleration of dexamethasone release. The accelerated release data were able to predict "real-time" release when applying the Arrhenius equation. Microsphere batches with faster and slower release profiles were investigated under "real-time" and elevated temperature (60°C) conditions to determine the discriminatory ability of the method. The results demonstrated both the feasibility and the discriminatory ability of this USP apparatus 4 method for in vitro release testing of drug loaded PLGA microsphere/PVA hydrogel composites. This method may be appropriate for similar drug/device combination products and drug delivery systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Beneficial effects of benzodiazepine diazepam on chronic stress-induced impairment of hippocampal structural plasticity and depression-like behavior in mice.

    Science.gov (United States)

    Zhao, Yunan; Wang, Zhongli; Dai, Jianguo; Chen, Lin; Huang, Yufang; Zhan, Zhen

    2012-03-17

    Whether benzodiazepines (BZDs) have beneficial effects on the progress of chronic stress-induced impairment of hippocampal structural plasticity and major depression is uncertain. The present study designed four preclinical experiments to determine the effects of BZDs using chronic unpredictable stress model. In Experiment 1, several time course studies on behavior and hippocampus response to stress were conducted using the forced swim and tail suspension tests (FST and TST) as well as hippocampal structural plasticity markers. Chronic stress induced depression-like behavior in the FST and TST as well as decreased hippocampal structural plasticity that returned to normal within 3 wk. In Experiment 2, mice received p.o. administration of three diazepam dosages prior to each variate stress session for 4 wk. This treatment significantly antagonized the elevation of stress-induced corticosterone levels. Only low- (0.5mg/kg) and medium-dose (1mg/kg) diazepam blocked the detrimental effects of chronic stress. In Experiment 3, after 7 wk of stress sessions, daily p.o. diazepam administration during 1 wk recovery phase dose-dependently accelerated the recovery of stressed mice. In Experiment 4, 1 wk diazepam administration to control mice enhanced significantly hippocampal structural plasticity and induced an antidepressant-like behavioral effect, whereas 4 wk diazepam administration produced opposite effects. Hence, diazepam can slow the progress of chronic stress-induced detrimental consequences by normalizing glucocorticoid hormones. Considering the adverse effect of long-term diazepam administration on hippocampal plasticity, the preventive effects of diazepam may depend on the proper dose. Short-term diazepam treatment enhances hippocampal structural plasticity and is beneficial to recovery following chronic stress. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Electrode system design for acceleration of ion beam of given initial emittance

    International Nuclear Information System (INIS)

    Dzmuran, R.; Kuzmiak, M.; Novy, F.

    1986-01-01

    A method is described for calculating beam optical equipment, proceeding from the fact that the motion of the ion beam is in fact a transmission of emittance in the direction of the motion. The calculation of the transmission of emittance is simplified when we assume the transmission in the form of erect phase ellipses. The calculation procedure was used to design a system of electrodes for ion beam acceleration, consisting of three thick electrostatic lenses: an extracting, an accomodating and an accelerating lens. A graphical representation is given of the transmission of the erect phase ellipse through the individual lenses and through the whole system, and tabulated are values of the beam divergence, both in dependence on the voltage ratio on the electrodes. (A.K.)

  18. Conceptual study of high power proton linac for accelerator driven subcritical nuclear power system

    International Nuclear Information System (INIS)

    Yu Qingchang; Ouyang Huafu; Xu Taoguang

    2002-01-01

    As a prior option of the next generation of energy source, the accelerator driven subcritical nuclear power system (ADS) can use efficiently the uranium and thorium resource, transmute the high-level long-lived radioactive wastes and raise nuclear safety. The ADS accelerator should provide the proton beam with tens megawatts. The superconducting linac is a good selection of ADS accelerator because of its high efficiency and low beam loss rate. The ADS accelerator presented by the authors consists of a 5 MeV radio-frequency quadrupole, a 100 MeV independently phased superconducting cavity linac and a 1 GeV elliptical superconducting cavity linac. The accelerating structures and main parameters are determined and the research and development plan is considered

  19. High power testing oa ANL X-band dielectric-loaded accelerating structures

    International Nuclear Information System (INIS)

    Power, J. G.; Gai, W.; Jing, C.; Konecny, R.; Gold, S. H.; Kinkead, A. K.

    2002-01-01

    In the second phase of a program to develop a compact accelerator based on a dielectric-loaded accelerating structure, we have conducted high power tests on a traveling-wave and a standing-wave prototype. Indications are that the traveling-wave structure achieved an accelerating gradient of 3-5 MV/m before the input coupling window failed, while the standing wave structure was poorly matched at high power due to contamination of copper residue on its coupling window. To solve both of these problems, a new method for coupling RF into the structures has been developed. The new couplers and the rest of the modular structure are currently under construction and will be tested at the Naval Research Laboratory shortly

  20. 2014 CERN Accelerator Schools: Plasma Wake Acceleration

    CERN Multimedia

    2014-01-01

    A specialised school on Plasma Wake Acceleration will be held at CERN, Switzerland from 23-29 November, 2014.   This course will be of interest to staff and students in accelerator laboratories, university departments and companies working in or having an interest in the field of new acceleration techniques. Following introductory lectures on plasma and laser physics, the course will cover the different components of a plasma wake accelerator and plasma beam systems. An overview of the experimental studies, diagnostic tools and state of the art wake acceleration facilities, both present and planned, will complement the theoretical part. Topical seminars and a visit of CERN will complete the programme. Further information can be found at: http://cas.web.cern.ch/cas/PlasmaWake2014/CERN-advert.html http://indico.cern.ch/event/285444/

  1. Handling and Transport of Oversized Accelerator Components and Physics Detectors

    CERN Document Server

    Prodon, S; Guinchard, M; Minginette, P

    2006-01-01

    For cost, planning and organisational reasons, it is often decided to install large pre-built accelerators components and physics detectors. As a result surface exceptional transports are required from the construction to the installation sites. Such heavy transports have been numerous during the LHC installation phase. This paper will describe the different types of transport techniques used to fit the particularities of accelerators and detectors components (weight, height, acceleration, planarity) as well as the measurement techniques for monitoring and the logistical aspects (organisation with the police, obstacles on the roads, etc). As far as oversized equipment is concerned, the lowering into the pit is challenging, as well as the transport in tunnel galleries in a very scare space and without handling means attached to the structure like overhead travelling cranes. From the PS accelerator to the LHC, handling systems have been developed at CERN to fit with these particular working conditions. This pap...

  2. Lactate metabolism in chronic liver disease

    DEFF Research Database (Denmark)

    Jeppesen, Johanne B; Mortensen, Christian; Bendtsen, Flemming

    2013-01-01

    Background. In the healthy liver there is a splanchnic net-uptake of lactate caused by gluconeogenesis. It has previously been shown that patients with acute liver failure in contrast have a splanchnic release of lactate caused by a combination of accelerated glycolysis in the splanchnic region...... and a reduction in hepatic gluconeogenesis. Aims. The aims of the present study were to investigate lactate metabolism and kinetics in patients with chronic liver disease compared with a control group with normal liver function. Methods. A total of 142 patients with chronic liver disease and 14 healthy controls...... underwent a liver vein catheterization. Blood samples from the femoral artery and the hepatic and renal veins were simultaneously collected before and after stimulation with galactose. Results. The fasting lactate levels, both in the hepatic vein and in the femoral artery, were higher in the patients than...

  3. [Morphologic characteristic of chronic toxic hepatitis for treatment with Neoselen].

    Science.gov (United States)

    Isroilov, R I; Salikhodzhaeva, U Sh

    2011-01-01

    The purpose of the given research work was to study the features of morphologic changes arising for treatment of chronic hepatitis with Neoselen. It was established a picture of chronic active hepatitis in the liver of rats with the following development of chronic persisting hepatitis by the 40 daily administration of heliotrine and its transmission into cirrhosis in a certain part of animals. Hepatic cirrhosis has a small nodal portal character by its pathognomonic morphologic signs. A noticeable remittance of destructive necrotic changes in hepatic parenchymatous elements and reduction in a volume of proliferative inflammatory infiltration with an acceleration in process of its fibrozation in only periportal zones of hepatic lobules found to be for treatment of chronic hepatitis with Neoselen. That prevents from transmission of chronic hepatitis into cirrhosis in a greater part of animals that is a morphologic evidence of importance of selenium in a restorative process of biologic membranes and its involvement in a remittance process of destructive and inflammatory changes in the liver and prevention from development of agressive hepatitis and its transmission into cirrhosis.

  4. Vascular toxicity of urea, a new “old player” in the pathogenesis of chronic renal failure induced cardiovascular diseases

    Science.gov (United States)

    D’Apolito, Maria; Brownlee, Michael; Maffione, Angela Bruna; Colia, Anna Laura; Sacco, Michele; Ferrara, Pietro; Pettoello-Mantovani, Massimo

    2017-01-01

    Chronic kidney disease in children is an irreversible process that may lead to end-stage renal disease. The mortality rate in children with end-stage renal disease who receive dialysis increased dramatically in the last decade, and it is significantly higher compared with the general pediatric population. Furthermore, dialysis and transplant patients, who have developed end-stage renal disease during childhood, live respectively far less as compared with age/race-matched populations. Different reports show that cardiovascular disease is the leading cause of death in children with end-stage renal disease and in adults with childhood-onset chronic kidney disease, and that children with chronic kidney disease are in the highest risk group for the development of cardiovascular disease. Urea, which is generated in the liver during catabolism of amino acids and other nitrogenous metabolites, is normally excreted into the urine by the kidneys as rapidly as it is produced. When renal function is impaired, increasing concentrations of blood urea will steadily accumulate. For a long time, urea has been considered to have negligible toxicity. However, the finding that plasma urea is the only significant predictor of aortic plaque area fraction in an animal model of chronic renal failure -accelerated atherosclerosis, suggests that the high levels of urea found in chronic dialysis patients might play an important role in accelerated atherosclerosis in this group of patients. The aim of this review was to provide novel insights into the role played by urea in the pathogenesis of accelerated cardiovascular disease in renal failure. PMID:29483797

  5. Development of a 20 MeV Dielectric-Loaded Test Accelerator

    International Nuclear Information System (INIS)

    Gold, Steven H.; Fliflet, Arne W.; Lombardi, Marcie; Kinkead, Allen K.; Gai, Wei; Power, John G.; Konecny, Richard; Long, Jidong; Jing, Chunguang; Tantawi, Sami G.; Nantista, Christopher D.; Bruce, Ralph W.; Lewis, David III

    2006-01-01

    This paper presents a progress report on a joint project by the Naval Research Laboratory (NRL) and Argonne National Laboratory (ANL), in collaboration with the Stanford Linear Accelerator Center (SLAC), to develop a dielectric-loaded test accelerator in the magnicon facility at NRL. The accelerator will be powered by an experimental 11.424-GHz magnicon amplifier that presently produces 25 MW of output power in a ∼250-ns pulse at up to 10 Hz. The accelerator will include a 5-MeV electron injector originally developed at the Tsinghua University in Beijing, China, and can incorporate DLA structures up to 0.5 m in length. The DLA structures are being developed by ANL, and shorter test structures fabricated from a variety of dielectric materials have undergone testing at NRL at gradients up to ∼8 MV/m. SLAC has developed components to distribute the power from the two magnicon output arms to the injector and to the DLA accelerating structure with separate control of the power ratio and relative phase. RWBruce Associates, Inc., working with NRL, has investigated means to join short ceramic sections into a continuous accelerator tube by a brazing process using an intense 83-GHz beam. The installation and testing of the first dielectric-loaded test accelerator, including injector, DLA test structure, and spectrometer, should take place within the next year

  6. Isentropic Compression of Iron with the Z Accelerator

    International Nuclear Information System (INIS)

    Asay, J.R.; Bernard, M.A.; Hall, C.A.; Hayes, D.B.; Holland, K.G.; McDaniel, D.H.; Rosenthal, S.E.; Spielman, R.B.; Stygar, W.A.

    1999-01-01

    Development of isentropic loading techniques is a long standing goal of the shock physics community. The authors have used the Sandia Z Accelerator to produce smoothly increasing pressure loading on planar iron specimens over time durations of 100 ns and for pressures to 300 Mbar. Free surface velocity measurements on the rear surface of the continuously loaded specimens were made on specimens 0.5-mm and 0.8-mm thick and clearly show the effects of wave evolution into the well known two-wave structure resulting from the α-var e psilon phase transition beginning at 125 kbar. The resulting wave profiles are analyzed with a rate-dependent, phase transition model to extract information on phase transformation kinetics for isentropic compression of iron. Comparison of the experiments and calculations demonstrate the value of isentropic loading for studying phase transition kinetics

  7. Design for simultaneous acceleration of stable and unstable beams in a superconducting heavy-ion linear accelerator for RISP

    Science.gov (United States)

    Kim, Jongwon; Son, Hyock-Jun; Park, Young-Ho

    2017-11-01

    The post-accelerator of isotope separation on-line (ISOL) system for rare isotope science project (RISP) is a superconducting linear accelerator (SC-linac) with a DC equivalent voltage of around 160 MV. An isotope beam extracted from the ISOL is in a charge state of 1+ and its charge state is increased to n+ by charge breeding with an electron beam ion source (EBIS). The charge breeding takes tens of ms and the pulse width of extracted beam from the EBIS is tens of μs, which operates at up to 30 Hz. Consequently a large portion of radio frequency (rf) time of the post SC-linac is unused. The post-linac is equipped also with an electron cyclotron resonance (ECR) ion source for stable ion acceleration. Thanks to the large phase acceptance of SC-linac, it is possible to accelerate simultaneously both stable and radioisotope ions with a similar charge to mass ratio by sharing rf time. This operation scheme is implemented for RISP with the addition of an electric chopper and magnetic kickers. The facility will be capable of providing the users of the ISOL and in-flight fragmentation (IF) systems with different beams simultaneously, which would help nuclear science users in obtaining a beam time as high-precision measurements often need long hours.

  8. Accelerating Research Innovation by Adopting the Lean Startup Paradigm

    Directory of Open Access Journals (Sweden)

    Kaisa Still

    2017-05-01

    Full Text Available Converting scientific expertise into marketable products and services is playing an increasingly important role in the launching of new ventures, the growth of existing firms, and the creation of new jobs. In this article, we explore how the lean startup paradigm, which validates the market for a product with a business model that can sustain subsequent scaling, has led to a new process model to accelerate innovation. We then apply this paradigm to the context of research at universities and other research organizations. The article is based on the assumption that the organizational context matters, and it shows how a deeper understanding of the research context could enable an acceleration of the innovation process. We complement theoretical examples with a case example from VTT Technical Research Institute of Finland. Our findings show that many of the concepts from early-acceleration phases – and the lean startup paradigm – can also be relevant in innovation discussions within the research context. However, the phase of value-proposition discovery is less adequately addressed, and that of growth discovery, with its emphasis on building on a scalable, sustainable business does not seem to be addressed with the presented innovation approaches from the research context. Hence, the entrepreneurial activities at the research context differ from those in startups and internal startups in established organizations.

  9. Chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    V K Vijayan

    2013-01-01

    Full Text Available The global prevalence of physiologically defined chronic obstructive pulmonary disease (COPD in adults aged >40 yr is approximately 9-10 per cent. Recently, the Indian Study on Epidemiology of Asthma, Respiratory Symptoms and Chronic Bronchitis in Adults had shown that the overall prevalence of chronic bronchitis in adults >35 yr is 3.49 per cent. The development of COPD is multifactorial and the risk factors of COPD include genetic and environmental factors. Pathological changes in COPD are observed in central airways, small airways and alveolar space. The proposed pathogenesis of COPD includes proteinase-antiproteinase hypothesis, immunological mechanisms, oxidant-antioxidant balance, systemic inflammation, apoptosis and ineffective repair. Airflow limitation in COPD is defined as a postbronchodilator FEV1 (forced expiratory volume in 1 sec to FVC (forced vital capacity ratio <0.70. COPD is characterized by an accelerated decline in FEV1. Co morbidities associated with COPD are cardiovascular disorders (coronary artery disease and chronic heart failure, hypertension, metabolic diseases (diabetes mellitus, metabolic syndrome and obesity, bone disease (osteoporosis and osteopenia, stroke, lung cancer, cachexia, skeletal muscle weakness, anaemia, depression and cognitive decline. The assessment of COPD is required to determine the severity of the disease, its impact on the health status and the risk of future events (e.g., exacerbations, hospital admissions or death and this is essential to guide therapy. COPD is treated with inhaled bronchodilators, inhaled corticosteroids, oral theophylline and oral phosphodiesterase-4 inhibitor. Non pharmacological treatment of COPD includes smoking cessation, pulmonary rehabilitation and nutritional support. Lung volume reduction surgery and lung transplantation are advised in selected severe patients. Global strategy for the diagnosis, management and prevention of Chronic Obstructive Pulmonary Disease

  10. LOO: a low-order nonlinear transport scheme for acceleration of method of characteristics

    International Nuclear Information System (INIS)

    Li, Lulu; Smith, Kord; Forget, Benoit; Ferrer, Rodolfo

    2015-01-01

    This paper presents a new physics-based multi-grid nonlinear acceleration method: the low-order operator method, or LOO. LOO uses a coarse space-angle multi-group method of characteristics (MOC) neutron transport calculation to accelerate the fine space-angle MOC calculation. LOO is designed to capture more angular effects than diffusion-based acceleration methods through a transport-based low-order solver. LOO differs from existing transport-based acceleration schemes in that it emphasizes simplified coarse space-angle characteristics and preserves physics in quadrant phase-space. The details of the method, including the restriction step, the low-order iterative solver and the prolongation step are discussed in this work. LOO shows comparable convergence behavior to coarse mesh finite difference on several two-dimensional benchmark problems while not requiring any under-relaxation, making it a robust acceleration scheme. (author)

  11. Analyzing radial acceleration with a smartphone acceleration sensor

    Science.gov (United States)

    Vogt, Patrik; Kuhn, Jochen

    2013-03-01

    This paper continues the sequence of experiments using the acceleration sensor of smartphones (for description of the function and the use of the acceleration sensor, see Ref. 1) within this column, in this case for analyzing the radial acceleration.

  12. Quantitative phase imaging of platelets in patients with chronic renal failure treated with hemodialysis

    Science.gov (United States)

    Vasilenko, Irina; Vlasova, Elizaveta; Metelin, Vladislav; Kardasheva, Ziver

    2018-02-01

    The development of robust non-invasive laboratory screening methods for early diagnosis on the out-patient basis seems quite relevant for practical medicine. It is known, that platelet is an original biosensor, a detector of early changes in hemostasis condition. The aim of this study was to assess a potential of the quantitative phase imaging (QPI) technique for real time evaluation the influence of low-molecular weight and unfractionated heparin on platelets in patients with the end-stage of chronic renal failure, who were treated with program hemodialysis (PHD). The main group consisted of 21 patients who were administered a low-molecular weight heparin for hypocoagulation during the procedure of hemodialysis. The control group (15 patients) received unfractionated heparin. Morphodensitometric state of living platelets we evaluated by QPI using computer phase-interference microscope MIM (Moscow, Russia). We analyzed the optical-geometrical parameters and the morphological features of living platelets which reflected the degree of their activation at the beginning of PHD (before administration of heparin), in 15 minutes after it and at the end of the procedure. The results allow us to conclude that the use of low-molecular weight heparin provides better ratio of efficacy/safety and causes a reduction of the platelet activation during the hemodialysis procedure. Practical implementation of QPI for clinical monitoring of platelets makes it possible to obtain important information on hemostasis cell. It opens new opportunities to assess the efficacy of treatment, as well as for early diagnosis of complications for disease.

  13. Simulation of isothermal multi-phase fuel-coolant interaction using MPS method with GPU acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Gou, W.; Zhang, S.; Zheng, Y. [Zhejiang Univ., Hangzhou (China). Center for Engineering and Scientific Computation

    2016-07-15

    The energetic fuel-coolant interaction (FCI) has been one of the primary safety concerns in nuclear power plants. Graphical processing unit (GPU) implementation of the moving particle semi-implicit (MPS) method is presented and used to simulate the fuel coolant interaction problem. The governing equations are discretized with the particle interaction model of MPS. Detailed implementation on single-GPU is introduced. The three-dimensional broken dam is simulated to verify the developed GPU acceleration MPS method. The proposed GPU acceleration algorithm and developed code are then used to simulate the FCI problem. As a summary of results, the developed GPU-MPS method showed a good agreement with the experimental observation and theoretical prediction.

  14. SIRIUS - A new 6 MV accelerator system for IBA and AMS at ANSTO

    Science.gov (United States)

    Pastuovic, Zeljko; Button, David; Cohen, David; Fink, David; Garton, David; Hotchkis, Michael; Ionescu, Mihail; Long, Shane; Levchenko, Vladimir; Mann, Michael; Siegele, Rainer; Smith, Andrew; Wilcken, Klaus

    2016-03-01

    The Centre for Accelerator Science (CAS) facility at ANSTO has been expanded with a new 6 MV tandem accelerator system supplied by the National Electrostatic Corporation (NEC). The beamlines, end-stations and data acquisition software for the accelerator mass spectrometry (AMS) were custom built by NEC for rare isotope mass spectrometry, while the beamlines with end-stations for the ion beam analysis (IBA) are largely custom designed at ANSTO. An overview of the 6 MV system and its performance during testing and commissioning phase is given with emphasis on the IBA end-stations and their applications for materials modification and characterisation.

  15. Beam dynamics studies of the Heavy Ion Fusion Accelerator injector

    International Nuclear Information System (INIS)

    Henestroza, E.; Yu, S.S.; Eylon, S.

    1995-04-01

    A driver-scale injector for the Heavy Ion Fusion Accelerator project has been built at LBL. This machine has exceeded the design goals of high voltage (> 2 MV), high current (> 0.8 A of K + ) and low normalized emittance (< 1 π mm-mr). The injector consists of a 750 keV diode pre-injector followed by an electrostatic quadrupole accelerator (ESQ) which provides strong (alternating gradient) focusing for the space-charge dominated beam and simultaneously accelerates the ions to 2 MeV. The fully 3-D PIC code WARP together with EGUN and POISSON were used to design the machine and analyze measurements of voltage, current and phase space distributions. A comparison between beam dynamics characteristics as measured for the injector and corresponding computer calculations will be presented

  16. Simulation and characterization of the RF system and global stability analysis at the REGAE linear electron accelerator

    International Nuclear Information System (INIS)

    Mayet, Frank

    2012-12-01

    LAOLA (LAboratory for Laser- and beam-driven plasma Acceleration), is a collaboration between groups from DESY and the University of Hamburg. Its mission is to complement basic research in the relatively new field of plasma wakefield acceleration (PWA) by an explicit combination with DESY's conventional, modern accelerators. The linear electron accelerator REGAE is designed to produce sub 10 fs low charge electron bunches with ultra-low emittance at a repetition rate of 50 Hz. The planned experiments include femtosecond electron diffraction (R.J. Dwayne Miller), as well as the probing of laser induced plasma wakefields with well characterized bunches (LAOLA). They all require high bunch time of flight stability down to 10 fs. The REGAE machine consists of two RF cavities, both fed by a single klystron. While the first one - the gun cavity - is used for acceleration of the electrons, the second one - the buncher cavity - can be used to reduce the electron bunch length. This scheme only works for a specific RF phase relation between the two cavities. This thesis is split into two parts. In the first one the implications of the unique two cavity design on day-to-day machine operation are analyzed. To this end an analytical model of the RF system is developed, which is necessary for understanding how to individually adjust the cavity phases. In the second part the influence of the setup on time of flight stability is discussed with an emphasis on phase jitter compensation. RF phase stability measurements reveal that the current machine setup allows for a time of flight stability down to 50 fs right after the gun.

  17. Simulation and characterization of the RF system and global stability analysis at the REGAE linear electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Mayet, Frank

    2012-12-15

    LAOLA (LAboratory for Laser- and beam-driven plasma Acceleration), is a collaboration between groups from DESY and the University of Hamburg. Its mission is to complement basic research in the relatively new field of plasma wakefield acceleration (PWA) by an explicit combination with DESY's conventional, modern accelerators. The linear electron accelerator REGAE is designed to produce sub 10 fs low charge electron bunches with ultra-low emittance at a repetition rate of 50 Hz. The planned experiments include femtosecond electron diffraction (R.J. Dwayne Miller), as well as the probing of laser induced plasma wakefields with well characterized bunches (LAOLA). They all require high bunch time of flight stability down to 10 fs. The REGAE machine consists of two RF cavities, both fed by a single klystron. While the first one - the gun cavity - is used for acceleration of the electrons, the second one - the buncher cavity - can be used to reduce the electron bunch length. This scheme only works for a specific RF phase relation between the two cavities. This thesis is split into two parts. In the first one the implications of the unique two cavity design on day-to-day machine operation are analyzed. To this end an analytical model of the RF system is developed, which is necessary for understanding how to individually adjust the cavity phases. In the second part the influence of the setup on time of flight stability is discussed with an emphasis on phase jitter compensation. RF phase stability measurements reveal that the current machine setup allows for a time of flight stability down to 50 fs right after the gun.

  18. Sustained Local Release of NGF from a Chitosan-Sericin Composite Scaffold for Treating Chronic Nerve Compression.

    Science.gov (United States)

    Zhang, Lei; Yang, Wen; Tao, Kaixiong; Song, Yu; Xie, Hongjian; Wang, Jian; Li, Xiaolin; Shuai, Xiaoming; Gao, Jinbo; Chang, Panpan; Wang, Guobin; Wang, Zheng; Wang, Lin

    2017-02-01

    Chronic nerve compression (CNC), a common form of peripheral nerve injury, always leads to chronic peripheral nerve pain and dysfunction. Current available treatments for CNC are ineffective as they usually aim to alleviate symptoms at the acute phase with limited capability toward restoring injured nerve function. New approaches for effective recovery of CNC injury are highly desired. Here we report for the first time a tissue-engineered approach for the repair of CNC. A genipin cross-linked chitosan-sericin 3D scaffold for delivering nerve growth factor (NGF) was designed and fabricated. This scaffold combines the advantages of both chitosan and sericin, such as high porosity, adjustable mechanical properties and swelling ratios, the ability of supporting Schwann cells growth, and improving nerve regeneration. The degradation products of the composite scaffold upregulate the mRNA levels of the genes important for facilitating nerve function recovery, including glial-derived neurotrophic factor (GDNF), early growth response 2 (EGR2), and neural cell adhesion molecule (NCAM) in Schwann cells, while down-regulating two inflammatory genes' mRNA levels in macrophages, tumor necrosis factor alpha (TNF-α), and interleukin-1 beta (IL-1β). Importantly, our tissue-engineered strategy achieves significant nerve functional recovery in a preclinical CNC animal model by decreasing neuralgia, improving nerve conduction velocity (NCV), accelerating microstructure restoration, and attenuating gastrocnemius muscles dystrophy. Together, this work suggests a promising clinical alternative for treating chronic peripheral nerve compression injury.

  19. The ATOMKI Accelerator Center

    International Nuclear Information System (INIS)

    Biri, S.; Kormany, Z.; Berzi, I.; Hunyadi, M.

    2009-01-01

    used for systematic maintenance was 328 hours. The breakdown periods amounted to only 2 hours last year. So the cyclotron was available for users during 1679 hours and the users required 1242 hours. The effectively used beam-on-target time is summarized in Table 2. The accelerated particles and the most frequent or typical energies were: proton (44%, 14.5 MeV), deuteron ( 29%, 10 MeV), alpha (16%, 12.5-15 MeV), He-3 ( 11%, 24 Mev). The renewal project of the nuclear magnetic resonance (NMR) based field stabilization system for the energy analyzing magnet has been completed. The original analogue signal processing units were replaced by a newly developed digital system. It first digitizes the low-frequency amplitude modulated signal of the marginal oscillator and then searches for the NMR-resonance. If the resonance is found then the phase of the resonance signal is measured compared to the field modulating sine wave. Based on this measured phase value the control voltage of the analyzing magnet power supply is adjusted automatically. The system hardware was built applying a C8051F041 mixed signal microcontroller, containing all the peripherals required for the measurement and control of the different components. Signal processing and power supply control is implemented by the microcontroller program and the operator can control the system through a GUI program running on a Windows PC. The new system has been in real operation since March 2009. It provides easy handling, user friendly and reliable operation with measured magnetic field stability values on the 2-3 x 10 -5 , level. The project of developing new power supplies for the low-current magnet coils of the cyclotron and the beam transport system has been continued. The prototype circuit of the new power supplies was designed, built and tested thoroughly. It contains modern high voltage tolerant IGBT components in the final stage. They are cooled by forced air, so we can get rid of the water cooling circuits used

  20. Measuring organizational readiness for knowledge translation in chronic care.

    Science.gov (United States)

    Gagnon, Marie-Pierre; Labarthe, Jenni; Légaré, France; Ouimet, Mathieu; Estabrooks, Carole A; Roch, Geneviève; Ghandour, El Kebir; Grimshaw, Jeremy

    2011-07-13

    Knowledge translation (KT) is an imperative in order to implement research-based and contextualized practices that can answer the numerous challenges of complex health problems. The Chronic Care Model (CCM) provides a conceptual framework to guide the implementation process in chronic care. Yet, organizations aiming to improve chronic care require an adequate level of organizational readiness (OR) for KT. Available instruments on organizational readiness for change (ORC) have shown limited validity, and are not tailored or adapted to specific phases of the knowledge-to-action (KTA) process. We aim to develop an evidence-based, comprehensive, and valid instrument to measure OR for KT in healthcare. The OR for KT instrument will be based on core concepts retrieved from existing literature and validated by a Delphi study. We will specifically test the instrument in chronic care that is of an increasing importance for the health system. Phase one: We will conduct a systematic review of the theories and instruments assessing ORC in healthcare. The retained theoretical information will be synthesized in a conceptual map. A bibliography and database of ORC instruments will be prepared after appraisal of their psychometric properties according to the standards for educational and psychological testing. An online Delphi study will be carried out among decision makers and knowledge users across Canada to assess the importance of these concepts and measures at different steps in the KTA process in chronic care.Phase two: A final OR for KT instrument will be developed and validated both in French and in English and tested in chronic disease management to measure OR for KT regarding the adoption of comprehensive, patient-centered, and system-based CCMs. This study provides a comprehensive synthesis of current knowledge on explanatory models and instruments assessing OR for KT. Moreover, this project aims to create more consensus on the theoretical underpinnings and the