WorldWideScience

Sample records for accelerated leach tests

  1. Accelerated leach test development program

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Pietrzak, R.F.; Heiser, J.; Franz, E.M.; Colombo, P.

    1990-11-01

    In FY 1989, a draft accelerated leach test for solidified waste was written. Combined test conditions that accelerate leaching were validated through experimental and modeling efforts. A computer program was developed that calculates test results and models leaching mechanisms. This program allows the user to determine if diffusion controls leaching and, if this is the case, to make projections of releases. Leaching mechanisms other than diffusion (diffusion plus source term partitioning and solubility limited leaching) are included in the program is indicators of other processes that may control leaching. Leach test data are presented and modeling results are discussed for laboratory scale waste forms composed of portland cement containing sodium sulfate salt, portland cement containing incinerator ash, and vinyl ester-styrene containing sodium sulfate. 16 refs., 38 figs., 5 tabs

  2. Accelerated Leach Test(s) Program. Annual report

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Fuhrmann, M.; Colombo, P.

    1985-09-01

    This report summarizes the work performed for the Accelerated Leach Test(s) Program at Brookhaven National Laboratory in Fiscal Year 1985 under the sponsorship of the US Department of Energy's Low-Level Waste Management Program (LLWMP). Programmatic activities were concentrated in three areas, as listed and described in the following paragraphs. (1) A literature survey of reported leaching mechanisms, available mathematical models and factors that affect leaching of LLW forms has been compiled. Mechanisms which have been identified include diffusion, dissolution, ion exchange, corrosion and surface effects. Available mathematical models are based on diffusion as the predominant mechanism. Although numerous factors that affect leaching have been identified, they have been conveniently categorized as factors related to the entire leaching system, to the leachant or to the waste form. A report has been published on the results of this literature survey. (2) A computerized data base of LLW leaching data and mathematical models is being developed. The data are being used for model evaluation by curve fitting and statistical analysis according to standard procedures of statistical quality control. (3) Long-term tests on portland cement, bitumen and vinyl ester-styrene (VES) polymer waste forms are underway which are designed to identify and evaluate factors that accelerate leaching without changing the mechanisms. Results on the effect of temperature on leachability indicate that the leach rates of cement and VES waste forms increase with increasing temperature, whereas, the leach rate of bitumen is little affected

  3. Optimizing conditions for an accelerated leach test

    International Nuclear Information System (INIS)

    Pietrzak, R.F.; Fuhrmann, M.; Heiser, J.; Franz, E.M.; Colombo, P.

    1988-01-01

    An accelerated leach test for low-level radioactive waste forms is being developed to provide, in a short time, data that can be extrapolated to long time periods. The approach is to provide experimental conditions that will accelerate leaching without changing the dominant release mechanism. Experimental efforts have focused on combining individual factors that have been observed to accelerate leaching. These include elevated temperature, increased leachant volume, and reduced specimen size. The response of diffusion coefficients to various acceleration factors have been evaluated and provide information on experimental parameters that need to be optimized to increase leach rates. Preliminary modeling using a diffusion mechanism (allowing for depletion) of a finite cylinder geometry indicates that during early portions of experiments (daily sampling intervals), leaching is diffusion controlled and more rapid than later in the same experiments (weekly or greater sampling intervals). For cement waste forms, this reduction in rate may be partially controlled by changes in physical structure and chemistry (sometimes related to environmental influences such as CO 2 ), but it is more likely associated with the duration of the sampling interval. By using a combination of mathematical modeling and by experimentally investigating various leach rate controlling factors, a more complete understanding of leaching processes is being developed. This, in turn, is leading to optimized accelerating conditions for a leach test

  4. Accelerated Leach Test(s) Program: Annual report

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Pietrzak, R.F.; Fuhrmann, M.; Colombo, P.

    1986-09-01

    A computerized data base of LLW leaching data has been developed. Long-term tests on portland cement, bitumen and vinyl ester-styrene (VES) polymer waste forms containing simulated wastes are underway which are designed to identify and evaluate factors that accelerate leaching without changing the mechanisms

  5. Optimizing conditions for an accelerated leach test

    International Nuclear Information System (INIS)

    Pietrzak, R.F.; Fuhrmann, M.; Heiser, J.; Franz, E.M.; Colombo, P.

    1988-01-01

    An accelerated leach test for low-level radioactive waste forms is being developed to provide, in a short time, data that can be extrapolated to long time periods. The approach is to provide experimental conditions that will accelerate leaching without changing the dominant release mechanism. Experimental efforts have focused on combining individual factors that have been observed to accelerate leaching. These include elevated temperature, increased leachant volume, and reduced specimen size. The response of diffusion coefficients to various acceleration factors have been evaluated and provide information on experimental parameters that need to be optimized to increase leach rates. For example, these data show that large volumes of leachant are required when leaching portland cement waste forms at elevated temperatures because of high concentrations of dissolved species. Sr-85 leaching is particularly susceptible to suppression due to concentration effects while Cs-137 leaching is less so. Preliminary modeling using a diffusion mechanism (allowing for depletion) of a finite cylinder geometry indicates that during early portions of experiments (daily sampling intervals), leaching is diffusion controlled and more rapid than later in the same experiments (weekly or greater sampling intervals). For cement waste forms, this reduction in rate may be partially controlled by changes in physical structure and chemistry (sometimes related to environmental influences such as CO 2 ), but it is more likely associated with the duration of the sampling interval. 9 refs., 6 figs

  6. Accelerated leach testing of radionuclides from solidified low-level waste

    International Nuclear Information System (INIS)

    Pietrzak, R.F.; Fuhrmann, M.; Franz, E.M.; Heiser, J. III; Colombo, P.

    1989-01-01

    This paper describes some of the work performed to develop an accelerated leach test designed to provide data that show long-term leaching behavior of solidified waste in a relatively short period of testing (1,2). The need for an accelerated leach test stems from the fact that the response of an effectively solidified waste form to the leaching process is so slow that a very long time is required to complete a test which shows the long-term leaching behavior of a waste form. Because of time limitations, as well as economic considerations, most studies have been limited to the early stages of the leaching process which is predominantly controlled by diffusion, although acknowledged to be due to also dissolution, corrosion or ion-exchange

  7. Development of an accelerated leach test(s) for low-level waste forms

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Fuhrmann, M.; Colombo, P.

    1986-01-01

    An accelerated leach test(s) is being developed to predict long-term leaching behavior of low-level radioactive waste (LLW) forms in their disposal environments. As necessary background, a literature survey of reported leaching mechanisms, available mathematical models and factors that affect leaching of LLW forms has been compiled. Mechanisms which have been identified include diffusion, dissolution, ion exchange, corrosion and surface effects. A computerized data base of LLW leaching data and mathematical models is being developed. The data is being used for model evaluation by curve fitting and statistical analysis according to standard procedures of statistical quality control. Long-term leach tests on portland cement, bitumen and vinyl ester-styrene (VES) polymer waste forms are underway which are designed to identify and evaluate factors that accelerate leaching without changing the mechanisms. Initial results on the effect of temperature on leachability indicate that the leach rates of cement and VES waste forms increase with increasing temperature, whereas, the leach rate of bitumen is little affected

  8. Development of an accelerated leach test(s) for low-level waste forms

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Fuhrmann, M.; Colombo, P.

    1985-01-01

    An accelerated leach test(s) is being developed to predict long-term leaching behavior of low-level radioactive waste (LLW) forms in their disposal environments. As necessary background, a literature survey of reported leaching mechanisms, available mathematical models and factors that affect leaching of LLW forms has been compiled. Mechanisms which have been identified include diffusion, dissolution, ion exchange, corrosion and surface effects. A computerized data base of LLW leaching data and mathematical models is being developed. The data is being used for model evaluation by curve fitting and statistical analysis according to standard procedures of statistical quality control. Long-term leach tests on portland cement, bitumen and vinyl ester-styrene (VES) polymer waste forms are underway which are designed to identify and evaluate factors that accelerate leaching without changing the mechanisms. Initial results on the effect of temperature on leachability indicate that the leach rates of cement and VES waste forms increase with increasing temperature, whereas, the leach rate of bitumen is little affected. 10 refs., 5 figs

  9. Method for accelerated leaching of solidified waste

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Heiser, J.H.; Pietrzak, R.F.; Franz, E.M.; Colombo, P.

    1990-11-01

    An accelerated leach test method has been developed to determine the maximum leachability of solidified waste. The approach we have taken is to use a semi-dynamic leach test; that is, the leachant is sampled and replaced periodically. Parameters such as temperature, leachant volume, and specimen size are used to obtain releases that are accelerated relative to other standard leach tests and to the leaching of full-scale waste forms. The data obtained with this test can be used to model releases from waste forms, or to extrapolate from laboratory-scale to full-scale waste forms if diffusion is the dominant leaching mechanism. Diffusion can be confirmed as the leaching mechanism by using a computerized mathematical model for diffusion from a finite cylinder. We have written a computer program containing several models including diffusion to accompany this test. The program and a Users' Guide that gives screen-by-screen instructions on the use of the program are available from the authors. 14 refs., 4 figs., 1 tab

  10. Glass-surface area to solution-volume ratio and its implications to accelerated leach testing

    International Nuclear Information System (INIS)

    Pederson, L.R.; Buckwalter, C.Q.; McVay, G.L.; Riddle, B.L.

    1982-10-01

    The value of glass surface area to solution volume ratio (SA/V) can strongly influence the leaching rate of PNL 76-68 glass. The leaching rate is largely governed by silicon solubility constraints. Silicic acid in solution reduced the elemental release of all glass components. No components are leached to depths greater than that of silicon. The presence of the reaction layer had no measurable effect on the rate of leaching. Accelerated leach testing is possible since PNL 76-68 glass leaching is solubility-controlled (except at very low SA/V values). A series of glasses leached with SA/V x time = constant will yield identical elemental release

  11. Effect of precipitation pattern on leaching of preservative from treated wood and implications for accelerated testing

    Science.gov (United States)

    Stan Lebow

    2014-01-01

    There is a need to develop improved accelerated test methods for evaluating the leaching of wood preservatives from treated wood exposed to precipitation. In this study the effects of rate of rainfall and length of intervals between rainfall events on leaching was evaluated by exposing specimens to varying patterns of simulated rainfall under controlled laboratory...

  12. Optimization of the factors that accelerate leaching

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Pietrzak, R.F.; Franz, E.M.; Heiser, J.H. III; Colombo, P.

    1989-03-01

    The prediction of long-term leachability of low-level radioactive waste forms is an essential element of disposal-site performance assessment. This report describes experiments and modeling techniques used to develop an accelerated leach test that meets this need. The acceleration in leaching rates caused by the combinations of two or more factors were experimentally determined. These factors were identified earlier as being able to individually accelerate leaching. They are: elevated temperature, the size of the waste form, the ratio of the volume of leachant to the surface area of the waste form, and the frequency of replacement of the leachant. The solidification agents employed were ones that are currently used to treat low-level radioactive wastes, namely portland type I cement, bitumen, and vinyl ester-styrene. The simulated wastes, sodium sulfate, sodium tetraborate, and incinerator ash, are simplified representatives of typical low-level waste streams. Experiments determined the leaching behavior of the radionuclides of cesium (Cs-137), strontium (Sr-85), and cobalt (Co-60 or Co-57) from several different formulations of solidification agents and waste types. Leaching results were based upon radiochemical and elemental analyses of aliquots of the leachate, and on its total alkalinity and pH at various times during the experiment (up to 120 days). Solid phase analyses were carried out by Scanning/Electron Microscopy and Energy Dispersive Spectroscopy on the waste forms before and after some leaching experiments. 43 refs., 96 figs., 16 tabs

  13. Accelerated Leach Testing of GLASS: ALTGLASS Version 3.0

    Energy Technology Data Exchange (ETDEWEB)

    Trivelpiece, Cory L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jantzen, Carol M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Crawford, Charles L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-12-31

    The Accelerated Leach Testing of GLASS (ALTGLASS) database is a collection of data from short- and long-term product consistency tests (PCT, ASTM C1285 A and B) on high level waste (HLW) as well as low activity waste (LAW) glasses. The database provides both U.S. and international researchers with an archive of experimental data for the purpose of studying, modeling, or validating existing models of nuclear waste glass corrosion. The ALTGLASS database is maintained and updated by researchers at the Savannah River National Laboratory (SRNL). This newest version, ALTGLASS Version 3.0, has been updated with an additional 503 rows of data representing PCT results from corrosion experiments conducted in the United States by the Savannah River National Laboratory, Pacific Northwest National Laboratory, Argonne National Laboratory, and the Vitreous State Laboratory (SRNL, PNNL, ANL, VSL, respectively) as well as the National Nuclear Laboratory (NNL) in the United Kingdom.

  14. Accelerated Leach Testing of GLASS: ALTGLASS Version 3.0

    International Nuclear Information System (INIS)

    Trivelpiece, Cory L.; Jantzen, Carol M.; Crawford, Charles L.

    2016-01-01

    The Accelerated Leach Testing of GLASS (ALTGLASS) database is a collection of data from short- and long-term product consistency tests (PCT, ASTM C1285 A and B) on high level waste (HLW) as well as low activity waste (LAW) glasses. The database provides both U.S. and international researchers with an archive of experimental data for the purpose of studying, modeling, or validating existing models of nuclear waste glass corrosion. The ALTGLASS database is maintained and updated by researchers at the Savannah River National Laboratory (SRNL). This newest version, ALTGLASS Version 3.0, has been updated with an additional 503 rows of data representing PCT results from corrosion experiments conducted in the United States by the Savannah River National Laboratory, Pacific Northwest National Laboratory, Argonne National Laboratory, and the Vitreous State Laboratory (SRNL, PNNL, ANL, VSL, respectively) as well as the National Nuclear Laboratory (NNL) in the United Kingdom.

  15. Development of an accelerated leaching method for incineration bottom ash correlated to toxicity characteristic leaching protocol.

    Science.gov (United States)

    Lin, Shengxuan; Zhou, Xuedong; Ge, Liya; Ng, Sum Huan; Zhou, Xiaodong; Chang, Victor Wei-Chung

    2016-10-01

    Heavy metals and some metalloids are the most significant inorganic contaminants specified in toxicity characteristic leaching procedure (TCLP) in determining the safety of landfills or further utilization. As a consequence, a great deal of efforts had been made on the development of miniaturized analytical devices, such as Microchip Electrophoresis (ME) and μTAS for on-site testing of heavy metals and metalloids to prevent spreading of those pollutants or decrease the reutilization period of waste materials such as incineration bottom ash. However, the bottleneck lied in the long and tedious conventional TCLP that requires 18 h of leaching. Without accelerating the TCLP process, the on-site testing of the waste material leachates was impossible. In this study, therefore, a new accelerated leaching method (ALM) combining ultrasonic assisted leaching with tumbling was developed to reduce the total leaching time from 18 h to 30 min. After leaching, the concentrations of heavy metals and metalloids were determined with ICP-MS or ICP-optical emission spectroscopy. No statistical significance between ALM and TCLP was observed for most heavy metals (i.e., cobalt, manganese, mercury, molybdenum, nickel, silver, strontium, and tin) and metalloids (i.e., arsenic and selenium). For the heavy metals with statistical significance, correlation factors derived between ALM and TCLP were 0.56, 0.20, 0.037, and 0.019 for barium, cadmium, chromium, and lead, respectively. Combined with appropriate analytical techniques (e.g., ME), the ALM can be applied to rapidly prepare the incineration bottom ash samples as well as other environmental samples for on-site determination of heavy metals and metalloids. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Large Scale Leach Test Facility: Development of equipment and methods, and comparison to MCC-1 leach tests

    International Nuclear Information System (INIS)

    Pellarin, D.J.; Bickford, D.F.

    1985-01-01

    This report describes the test equipment and methods, and documents the results of the first large-scale MCC-1 experiments in the Large Scale Leach Test Facility (LSLTF). Two experiments were performed using 1-ft-long samples sectioned from the middle of canister MS-11. The leachant used in the experiments was ultrapure deionized water - an aggressive and well characterized leachant providing high sensitivity for liquid sample analyses. All the original test plan objectives have been successfully met. Equipment and procedures have been developed for large-sample-size leach testing. The statistical reliability of the method has been determined, and ''bench mark'' data developed to relate small scale leach testing to full size waste forms. The facility is unique, and provides sampling reliability and flexibility not possible in smaller laboratory scale tests. Future use of this facility should simplify and accelerate the development of leaching models and repository specific data. The factor of less than 3 for leachability, corresponding to a 200,000/1 increase in sample volume, enhances the credibility of small scale test data which precedes this work, and supports the ability of the DWPF waste form to meet repository criteria

  17. To accelerate technology of in situ leaching and heap leaching for mining mineral resources of China

    International Nuclear Information System (INIS)

    Luo Mei

    1999-01-01

    Recently, in situ leaching and heap leaching are the most advanced technology for mining low-grade mineral resources in the world. The author briefly expounds the basic concept and advantages of in situ leaching and heap leaching and deals with the main research content of the hydrometallurgical technology of in situ leaching and heap leaching, its development and present application at home and abroad. Having expounded the gap existing between China's technology of in situ leaching and heap leaching and the foreign technology, the author forecasts the prospects of accelerating the mining of China's mineral resources by using the technology of in situ leaching and heap leaching

  18. Effect of accelerated carbonation and zero valent iron on metal leaching from bottom ash.

    Science.gov (United States)

    Nilsson, M; Andreas, L; Lagerkvist, A

    2016-05-01

    About 85% of the ashes produced in Sweden originated from the incineration of municipal solid waste and biofuel. The rest comes from the thermal treatment of recycled wood, peat, charcoal and others. About 68% of all ashes annually produced in Sweden are used for constructions on landfills, mainly slopes, roads and embankments, and only 3% for construction of roads and working surfaces outside the landfills (SCB, 2013). Since waste bottom ash (BA) often has similar properties to crushed bedrock or gravel, it could be used for road constructions to a larger extent. However, the leaching of e.g. Cr, Cu, Mo, Pb and Zn can cause a threat to the surrounding environment if the material is used as it is. Carbonation is a commonly used pre-treatment method, yet it is not always sufficient. As leaching from aged ash is often controlled by adsorption to iron oxides, increasing the number of Fe oxide sorption sites can be a way to control the leaching of several critical elements. The importance of iron oxides as sorption sites for metals is known from both mineralogical studies of bottom ash and from the remediation of contaminated soil, where iron is used as an amendment. In this study, zero valent iron (Fe(0)) was added prior to accelerated carbonation in order to increase the number of adsorption sites for metals and thereby reduce leaching. Batch, column and pHstat leaching tests were performed and the leaching behaviour was evaluated with multivariate data analysis. It showed that leaching changed distinctly after the tested treatments, in particular after the combined treatment. Especially, the leaching of Cr and Cu clearly decreased as a result of accelerated carbonation. The combination of accelerated carbonation with Fe(0) addition reduced the leaching of Cr and Cu even further and reduced also the leaching of Mo, Zn, Pb and Cd compared to untreated BA. Compared with only accelerated carbonation, the Fe(0) addition significantly reduced the leaching of Cr, Cu and Mo

  19. Standard test method for accelerated leach test for diffusive releases from solidified waste and a computer program to model diffusive, fractional leaching from cylindrical waste forms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides procedures for measuring the leach rates of elements from a solidified matrix material, determining if the releases are controlled by mass diffusion, computing values of diffusion constants based on models, and verifying projected long-term diffusive releases. This test method is applicable to any material that does not degrade or deform during the test. 1.1.1 If mass diffusion is the dominant step in the leaching mechanism, then the results of this test can be used to calculate diffusion coefficients using mathematical diffusion models. A computer program developed for that purpose is available as a companion to this test method (Note 1). 1.1.2 It should be verified that leaching is controlled by diffusion by a means other than analysis of the leach test solution data. Analysis of concentration profiles of species of interest near the surface of the solid waste form after the test is recommended for this purpose. 1.1.3 Potential effects of partitioning on the test results can...

  20. Reproducing ten years of road ageing - Accelerated carbonation and leaching of EAF steel slag

    International Nuclear Information System (INIS)

    Suer, Pascal; Lindqvist, Jan-Erik; Arm, Maria; Frogner-Kockum, Paul

    2009-01-01

    Reuse of industrial aggregates is still hindered by concern for their long-term properties. This paper proposes a laboratory method for accelerated ageing of steel slag, to predict environmental and technical properties, starting from fresh slag. Ageing processes in a 10-year old asphalt road with steel slag of electric arc furnace (EAF) type in the subbase were identified by scanning electron microscopy (SEM) and leaching tests. Samples from the road centre and the pavement edge were compared with each other and with samples of fresh slag. It was found that slag from the pavement edge showed traces of carbonation and leaching processes, whereas the road centre material was nearly identical to fresh slag, in spite of an accessible particle structure. Batches of moisturized road centre material exposed to oxygen, nitrogen or carbon dioxide (CO 2 ) were used for accelerated ageing. Time (7-14 days), temperature (20-40 o C) and initial slag moisture content (8-20%) were varied to achieve the carbonation (decrease in pH) and leaching that was observed in the pavement edge material. After ageing, water was added to assess leaching of metals and macroelements. 12% moisture, CO 2 and seven days at 40 o C gave the lowest pH value. This also reproduced the observed ageing effect for Ca, Cu, Ba, Fe, Mn, Pb, Ca (decreased leaching) and for V, Si, and Al (increased leaching). However, ageing effects on SO 4 , DOC and Cr were not reproduced.

  1. Copper leaching of MSWI bottom ash co-disposed with refuse: effect of short-term accelerated weathering.

    Science.gov (United States)

    Su, Lianghu; Guo, Guangzhai; Shi, Xinlong; Zuo, Minyu; Niu, Dongjie; Zhao, Aihua; Zhao, Youcai

    2013-06-01

    Co-disposal of refuse with municipal solid waste incinerator (MSWI) bottom ash (IBA) either multi-layered as landfill cover or mixed with refuse could pose additional risk to the environment because of enhanced leaching of heavy metals, especially Cu. This study applied short-term accelerated weathering to IBA, and monitored the mineralogical and chemical properties of IBA during the weathering process. Cu extractability of the weathered IBA was then evaluated using standard leaching protocols (i.e. SPLP and TCLP) and co-disposal leaching procedure. The results showed that weathering had little or no beneficial effect on Cu leaching in SPLP and TCLP, which can be explained by the adsorption and complexation of Cu with DOM. However, the Cu leaching of weathered IBA was reduced significantly when situated in fresh simulated landfill leachate. This was attributed to weakening Cu complexation with fulvic acid or hydrophilic fractions and/or intensifying Cu absorption to neoformed hydr(oxide) minerals in weathered IBA. The amount of total leaching Cu and Cu in free or labile complex fraction (the fraction with the highest mobility and bio-toxicity) of the 408-h weathered IBA were remarkably decreased by 86.3% and 97.6% in the 15-day co-disposal leaching test. Accelerated weathering of IBA may be an effective pretreatment method to decrease Cu leaching prior to its co-disposal with refuse. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Reproducing ten years of road ageing - Accelerated carbonation and leaching of EAF steel slag

    Energy Technology Data Exchange (ETDEWEB)

    Suer, Pascal, E-mail: pascal.suer@swedgeo.se [Swedish Geotechnical Institute, Linkoeping (Sweden); Lindqvist, Jan-Erik [Swedish Cement and Concrete Research Institute, Boras (Sweden); Arm, Maria; Frogner-Kockum, Paul [Swedish Geotechnical Institute, Linkoeping (Sweden)

    2009-09-01

    Reuse of industrial aggregates is still hindered by concern for their long-term properties. This paper proposes a laboratory method for accelerated ageing of steel slag, to predict environmental and technical properties, starting from fresh slag. Ageing processes in a 10-year old asphalt road with steel slag of electric arc furnace (EAF) type in the subbase were identified by scanning electron microscopy (SEM) and leaching tests. Samples from the road centre and the pavement edge were compared with each other and with samples of fresh slag. It was found that slag from the pavement edge showed traces of carbonation and leaching processes, whereas the road centre material was nearly identical to fresh slag, in spite of an accessible particle structure. Batches of moisturized road centre material exposed to oxygen, nitrogen or carbon dioxide (CO{sub 2}) were used for accelerated ageing. Time (7-14 days), temperature (20-40 {sup o}C) and initial slag moisture content (8-20%) were varied to achieve the carbonation (decrease in pH) and leaching that was observed in the pavement edge material. After ageing, water was added to assess leaching of metals and macroelements. 12% moisture, CO{sub 2} and seven days at 40 {sup o}C gave the lowest pH value. This also reproduced the observed ageing effect for Ca, Cu, Ba, Fe, Mn, Pb, Ca (decreased leaching) and for V, Si, and Al (increased leaching). However, ageing effects on SO{sub 4}, DOC and Cr were not reproduced.

  3. Some factors affecting agitation leach test during in-situ leaching of uranium

    International Nuclear Information System (INIS)

    Liao Wensheng; Jiang Yan; Wang Limin; Shi Zhenfeng; Zhao Qiaofu; MARMAR

    2014-01-01

    The agitation leaching test is one of the most fundamental research works in in-situ leaching of uranium. Some factors affecting the test results were analyzed including stirring, leaching time, oxidizer used in alkaline leach, washing solution, the amount and size of ore samples. The results indicate that stirring can enhance diffusion velocity. The leach time l or 2 days is suitable for the samples containing accessible uranium and low acid consumption minerals; whereas 3 or 4 days for those containing refractory ore to leach and slowly acid consuming minerals. For the oxidizer used in alkaline leach, potassium permanganate is better than hydrogen peroxide. Recovery calculated by the leach solution can be directly obtained by its uranium level and the original volume of lixiviant without analyzing and calculating the washing solution. The appropriate amount and size of ore samples for the agitation leaching test are 60 g and <1 mm. By controlling the above factors, the agitation leach test can improve the applicability of the different ore samples and give the more reliable data. (authors)

  4. Development of a computerized data base for low-level radioactive waste leaching data: Topical report

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Colombo, P.

    1986-09-01

    This report documents the development of a computerized data base (db) of leaching data for solidified low-level radioactive waste (LLW) forms. Brookhaven National Lab performed this work under contract with the US Department of Energy's Low-Level Waste Management Program as part of an effort to develop an accelerated leach test(s) that can be used to predict leachabilities of LLW forms over long time periods, i.e., hundreds of years. The accelerated leach test(s) is (are) to be developed based on knowledge of leaching mechanisms and factors that affect leaching. Although developed specifically for the Accelerated Leach Test(s) Program, this db may be useful to others concerned with the management of low-level waste. The db is being developed to provide efficient data compilation and analysis capabilities. The data compiled in the db, which include data from the Accelerated Leach Test(s) Program and selected data from the literature, have been selected to elucidate leaching mechanisms and factors that affect leaching and are not meant to be a comprehensive compilation of leaching data. This report presents the data compilation aspect of the db. It does not present the programmatic results obtained from analysis of the data regarding leaching mechanisms and factors that affect leaching, which will be presented in reports from the Accelerated Leach Test(s) Program. 6 refs

  5. Study on Leaching of Hexavalent Chromium from Hardened Concretes Using Tank Leaching Test

    OpenAIRE

    Takahashi, Shigeru; Sakai, Etsuo; Sugiyama, Takafumi

    2007-01-01

    Tank leaching tests were carried out to investigate the behavior of leaching trace elements from monolith samples. This study consists of two series, and the trace element used was hexavalent chromium. In Series I, the influence of the leachant/surface area of the specimen (L/S ratio) on the leaching amount was investigated. The leaching amount was found to increase with the amount of worked water. This shows that any L/S ratio can be selected in the tank leaching test. In Series II, th...

  6. Standard leach tests for nuclear waste materials

    International Nuclear Information System (INIS)

    Strachan, D.M.; Barnes, B.O.; Turcotte, R.P.

    1980-01-01

    Five leach tests were conducted to study time-dependent leaching of waste forms (glass). The first four tests include temperature as a variable and the use of three standard leachants. Three of the tests are static and two are dynamic (flow). This paper discusses the waste-form leach tests and presents some representative data. 4 figures

  7. Leaching Test Relationships, Laboratory-to-Field Comparisons and Recommendations for Leaching Evaluation using the Leaching Environmental Assessment Framework (LEAF)

    Science.gov (United States)

    This report presents examples of the relationships between the results of laboratory leaching tests, as defined by the Leaching Environmental Assessment Framework (LEAF) or analogous international test methods, and leaching of constituents from a broad range of materials under di...

  8. Dynamic leaching test of personal computer components.

    Science.gov (United States)

    Li, Yadong; Richardson, Jay B; Niu, Xiaojun; Jackson, Ollie J; Laster, Jeremy D; Walker, Aaron K

    2009-11-15

    A dynamic leaching test (DLT) was developed and used to evaluate the leaching of toxic substances for electronic waste in the environment. The major components in personal computers (PCs) including motherboards, hard disc drives, floppy disc drives, and compact disc drives were tested. The tests lasted for 2 years for motherboards and 1.5 year for the disc drives. The extraction fluids for the standard toxicity characteristic leaching procedure (TCLP) and synthetic precipitation leaching procedure (SPLP) were used as the DLT leaching solutions. A total of 18 elements including Ag, Al, As, Au, Ba, Be, Cd, Cr, Cu, Fe, Ga, Ni, Pd, Pb, Sb, Se, Sn, and Zn were analyzed in the DLT leachates. Only Al, Cu, Fe, Ni, Pb, and Zn were commonly found in the DLT leachates of the PC components. Their leaching levels were much higher in TCLP extraction fluid than in SPLP extraction fluid. The toxic heavy metal Pb was found to continuously leach out of the components over the entire test periods. The cumulative amounts of Pb leached out of the motherboards in TCLP extraction fluid reached 2.0 g per motherboard over the 2-year test period, and that in SPLP extraction fluid were 75-90% less. The leaching rates or levels of Pb were largely affected by the content of galvanized steel in the PC components. The higher was the steel content, the lower the Pb leaching rate would be. The findings suggest that the obsolete PCs disposed of in landfills or discarded in the environment continuously release Pb for years when subjected to landfill leachate or rains.

  9. Leach testing of waste forms: interrelationship of ISO and MCC type tests

    International Nuclear Information System (INIS)

    Oversby, V.M.

    1982-01-01

    Leach testing experiments were conducted on SYNROC-D material to examine the parameters which affect leaching results and to measure the activation energy for leaching of elements from SYNROC-D. Measured leach rates were found to be controlled by precipitation of insoluble phases for those tests where the sample surface area to volume of leachant (SA/V) multiplied by leaching time (t) exceeded 0.3 cm -1 d for leach tests at 90 0 C. In these cases the apparent activation energy for leaching was approximately 10 kcal/mole based on Na and Si data. For leach tests at 90 0 C with (Sa/V)(t) less than 0.2 cm -1 d, the activation energy for Na and Si dissolution was 18.5 kcal/mole for sample S29 and 14.5 kcal/mole for sample LSO4. The effect of sample geometry was investigated by leaching a series of crushed samples of different grain size. The results support the view that geometric surface area should be used in leach rate calculations rather than gas adsorption BET surface area. Comparison of results on S29 leaching of crushed samples and monoliths show that data from MCC-1 and ISO type leach tests may be directly compared when the data are examined at constant (SA/V)(t). 5 figures, 13 tables

  10. Bottle roll leach test for Temrezli uranium ore

    International Nuclear Information System (INIS)

    Çetin, K.; Bayrak, M.; Turan, A. İsbir; Üçgül, E.

    2014-01-01

    The bottle roll leach test is one of the dynamic leaching procedure which can meet in-situ mining needs for determining suitable working conditions and helps to simulate one of the important parameter; injection well design. In this test, the most important parameters are pulp density, acidic or basic concentration of leach solution, time and temperature. In recent years, bottle roll test is used not only for uranium but also gold, silver, copper and nickel metals where in situ leach (ISL) mining is going to be applied. For this purpose for gold and silver metal cyanide bottle roll tests and for uranium metal; acidic and basic bottle roll tests could be applied. The new leach test procedure which is held in General Directorate of Mineral Research and Exploration (MTA) of Turkey is mostly suitable for determining metal extraction conditions and recovery values in uranium containing ore bodies. The tests were conducted with samples taken from Temrezli Uranium Ore located in approximately 200 km east of Turkey’s capital, Ankara. Mining rights of Temrezli Ore is controlled 100% by Anatolia Energy Ltd. The resource estimate includes an indicated mineral resource of 10.827 Mlbs U_3O_8 [~4160 t U] at an average grade of 1426 ppm [~1210 ppm U] and an additional inferred resource of 6.587 Mlbs of U_3O_8 [~2530 t U] at an average grade of 904 ppm [~767 ppm U]. In accordance with the demand from Anatolia Energy bottle roll leach tests have been initiated in MTA laboratories to investigate the recovery values of low-grade uranium ore under in-situ leach conditions. Bottle roll leaching tests are performed on pulverized samples with representative lixiviant solution at ambient pressure and provide an initial evaluation of ore leachability with a rough estimate of recovery value. At the end of the tests by using 2 g/L NaHCO_3 and 0.2 g/L H_2O_2 more than 90% of uranium can pass into leach solution in 12 days. (author)

  11. Bacteria heap leaching test of a uranium ore

    International Nuclear Information System (INIS)

    Liu Hui; Liu Jinhui; Wu Weirong; Han Wei

    2008-01-01

    Column bioleaching test of a uranium ore was carried out. The optimum acidity, spraying intensity, spray-pause time ratio were determined. The potential, Fe and U concentrations in the leaching process were investigated. The effect of bacteria column leaching was compared with that of acid column leaching. The results show that bacteria column leaching can shorten leaching cycle, and the leaching rate of uranium increases by 9.7%. (authors)

  12. A New Generation of Leaching Tests – The Leaching Environmental Assessment Framework

    Science.gov (United States)

    Provides an overview of newly released leaching tests that provide a more accurate source term when estimating environmental release of metals and other constituents of potential concern (COPCs). The Leaching Environmental Assessment Framework (LEAF) methods have been (1) develo...

  13. Leach test methodology for the Waste/Rock Interactions Technology Program

    International Nuclear Information System (INIS)

    Bradley, D.J.; McVay, G.L.; Coles, D.G.

    1980-05-01

    Experimental leach studies in the WRIT Program have two primary functions. The first is to determine radionuclide release from waste forms in laboratory environments which attempt to simulate repository conditions. The second is to elucidate leach mechanisms which can ultimately be incorporated into nearfield transport models. The tests have been utilized to generate rates of removal of elements from various waste forms and to provide specimens for surface analysis. Correlation between constituents released to the solution and corresponding solid state profiles is invaluable in the development of a leach mechanism. Several tests methods are employed in our studies which simulate various proposed leach incident scenarios. Static tests include low temperature (below 100 0 C) and high temperature (above 100 0 C) hydrothermal tests. These tests reproduce nonflow or low-flow repository conditions and can be used to compare materials and leach solution effects. The dynamic tests include single-pass, continuous-flow(SPCF) and solution-change (IAA)-type tests in which the leach solutions are changed at specific time intervals. These tests simulate repository conditions of higher flow rates and can also be used to compare materials and leach solution effects under dynamic conditions. The modified IAEA test is somewhat simpler to use than the one-pass flow and gives adequate results for comparative purposes. The static leach test models the condition of near-zero flow in a repository and provides information on element readsorption and solubility limits. The SPCF test is used to study the effects of flowing solutions at velocities that may be anticipated for geologic groundwaters within breached repositories. These two testing methods, coupled with the use of autoclaves, constitute the current thrust of WRIT leach testing

  14. PEP Integrated Test D Run Report Caustic and Oxidative Leaching in UFP-VSL-T02A

    Energy Technology Data Exchange (ETDEWEB)

    Sevigny, Gary J.; Bredt, Ofelia P.; Burns, Carolyn A.; Kurath, Dean E.; Geeting, John GH; Golovich, Elizabeth C.; Guzman-Leong, Consuelo E.; Josephson, Gary B.

    2009-12-11

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes" of the External Flowsheet Review Team (EFRT) issue response plan. The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario (Test B and D) has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario (Test A) has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP and vessels UFP VSL-00001A and B in the WTP PTF). In Test D, 19M sodium hydroxide (NaOH, caustic) was added to the waste slurry in the UFP VSL T02 vessel after the solids were concentrated to ~20% undissolved solids. The NaOH was added to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by heating to 85°C using direct injection of steam to accelerate the leach process. The main difference of Test D compared to Test B is that the leach temperature is 85°C for 24 hrs as compared to 100°C for 12 hours. The other difference is the Test D simulant had Cr in the

  15. Leach testing of Idaho Chemical Processing Plant final waste forms

    International Nuclear Information System (INIS)

    Schuman, R.P.

    1980-01-01

    A number of pellets and highly durable glasses prepared from nonradioactive-simulated high-level wasste calcines have been leach tested. The leach tests are patterned on the IAEA standard test and the proposed Materials Characterization Center tests. Most tests are made with static distilled water at 25, 70, 95, 250, and 350 0 C and in refluxing distilled water, Soxhlet, at 95 0 C. Leach rates are determined by analyzing the leachate by instrumental activation analysis or spectrochemical analysis and from weight loss. Leaches are run on glass using cast and core drilled cylinders, broken pieces and coarse ground material. Sample form has a considerable effect on leach rates; solid pieces gave higher leach rates than ground glass when expressed in g/cm 2 /day. Cesium, molybdenum and weight loss leach rates of cast glass cylinders in distilled water varied from -7 g/cm 7 /day at 25 0 C to approx. 10 -3 g/cm 2 /day at 250 0 C. The leach rates in static distilled water at 95 0 C were considerably lower than those in refluxing distilled water, Soxhlet, at the same temperature. Even at 25 0 C, sodium, cesium, and molybdenum readily leached from the porous pellets, but the pellets showed no visible attack, even at 250 0 C

  16. Extended Leach Testing of Simulated LAW Cast Stone Monoliths

    Energy Technology Data Exchange (ETDEWEB)

    Serne, R. Jeffrey [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westsik, Joseph H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jung, H. B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Guohui [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-09

    This report describes the results from long-term laboratory leach tests performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate the release of key constituents from monoliths of Cast Stone prepared with four simulated low-activity waste (LAW) liquid waste streams. Specific objectives of the Cast Stone long-term leach tests described in this report focused on four activities: 1. Extending the leaching times for selected ongoing EPA-1315 tests on monoliths made with LAW simulants beyond the conventional 63-day time period up to 609 days reported herein (with some tests continuing that will be documented later) in an effort to evaluate long-term leaching properties of Cast Stone to support future performance assessment activities. 2. Starting new EPA-1315 leach tests on archived Cast Stone monoliths made with four LAW simulants using two leachants (deionized water [DIW] and simulated Hanford Integrated Disposal Facility (IDF) Site vadose zone pore water [VZP]). 3. Evaluating the impacts of varying the iodide loading (starting iodide concentrations) in one LAW simulant (7.8 M Na Hanford Tank Waste Operations Simulator (HTWOS) Average) by manufacturing new Cast Stone monoliths and repeating the EPA-1315 leach tests using DIW and the VZP leachants. 4. Evaluating the impacts of using a non-pertechnetate form of Tc that is present in some Hanford tanks. In this activity one LAW simulant (7.8 M Na HTWOS Average) was spiked with a Tc(I)-tricarbonyl gluconate species and then solidified into Cast Stone monoliths. Cured monoliths were leached using the EPA-1315 leach protocol with DIW and VZP. The leach results for the Tc-Gluconate Cast Stone monoliths were compared to Cast Stone monoliths pertechnetate.

  17. Development of a computerized data base for low-level waste leaching data

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Colombo, P.

    1987-01-01

    A computerized data base (db) of low-level waste (LLW) leaching data is being compiled by Brookhaven National Laboratory under contract to the DOE Low-Level Waste Management Program. Although this db is being compiled as part of an effort to develop accelerated leach test procedures for LLW forms, other involved in LLW management may find it useful. The db is implemented on an IBM PC XT and is self-contained in that its data manipulation and analysis programs are not proprietary (i.e., need not be purchased). The db includes data from the Accelerated Leach Test(s) Program plus selected literature data, which have been selected based on criteria that include completeness of the experimental description and elucidation of leaching mechanisms. 6 references, 5 figures, 3 tables

  18. Spent LWR fuel leach tests: Waste Isolation Safety Assessment program

    International Nuclear Information System (INIS)

    Katayama, Y.B.

    1979-04-01

    Spent light-water-reactor (LWR) fuels with burnups of 54.5, 28 and 9 MWd/kgU were leach-tested in deionized water at 25 0 C. Fuel burnup has no apparent effect on the calculated leach rates based upon the behavior of 137 Cs and 239+240 Pu. A leach test of 54.5 MWd/kgU spent fuel in synthetic sea brine showed that the cesium-based leach rate is lower in sea brine than in deionized water. A rise in the leach rate was observed after approximately 600 d of cumulative leaching. During the rise, the leach rate for all the measured radionuclides become nearly equal. Evidence suggests that exposure of new surfaces to the leachant may cause the increase. As a result, experimental work to study leaching mechanisms of spent fuel has been initiated. 22 figures

  19. EFRT M-12 Issue Resolution: Caustic Leach Rate Constants from PEP and Laboratory-Scale Tests

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Rassat, Scot D.; Eslinger, Paul W.; Aaberg, Rosanne L.; Aker, Pamela M.; Golovich, Elizabeth C.; Hanson, Brady D.; Hausmann, Tom S.; Huckaby, James L.; Kurath, Dean E.; Minette, Michael J.; Sundaram, S. K.; Yokuda, Satoru T.

    2009-08-14

    Testing Summary Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed and constructed and is to be operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP; vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct injection of steam to accelerate the leaching process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP-1, the 19-M NaOH is added to un-concentrated waste slurry (3 to 8 wt% solids), while for leaching in UFP-2, the slurry is

  20. EFRT M-12 Issue Resolution: Caustic Leach Rate Constants from PEP and Laboratory-Scale Tests

    International Nuclear Information System (INIS)

    Mahoney, Lenna A.; Rassat, Scot D.; Eslinger, Paul W.; Aaberg, Rosanne L.; Aker, Pamela M.; Golovich, Elizabeth C.; Hanson, Brady D.; Hausmann, Tom S.; Huckaby, James L.; Kurath, Dean E.; Minette, Michael J.; Sundaram, S. K.; Yokuda, Satoru T.

    2009-01-01

    Testing Summary Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed and constructed and is to be operated as part of a plan to respond to issue M12, 'Undemonstrated Leaching Processes.' The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP; vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct injection of steam to accelerate the leaching process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP-1, the 19-M NaOH is added to un-concentrated waste slurry (3 to 8 wt% solids), while for leaching in UFP-2, the slurry is concentrated

  1. Extended Leach Testing of Simulated LAW Cast Stone Monoliths

    Energy Technology Data Exchange (ETDEWEB)

    Serne, R. Jeffrey [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lanigan, David C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westsik, Joseph H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jung, H. B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Guohui [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-08-12

    This revision to the original report adds two longer term leach sets of data to the report and provides more discussion and graphics on how to interpret the results from long-term laboratory leach tests. The leach tests were performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate the release of key constituents from monoliths of Cast Stone prepared with four simulated low-activity waste (LAW) liquid waste streams.

  2. Evaluation of the leaching behavior of incineration bottom ash using seawater: A comparison with standard leaching tests.

    Science.gov (United States)

    Lin, Wenlin Yvonne; Heng, Kim Soon; Nguyen, Minh Quan; Ho, Jin Rui Ivan; Mohamed Noh, Omar Ahmad Bin; Zhou, Xue Dong; Liu, Alec; Ren, Fei; Wang, Jing-Yuan

    2017-04-01

    Batch and column tests were conducted on untreated incineration bottom ash (IBA) samples from two incineration plants in Singapore, using seawater as the leachant. The main objective of this study was to investigate the change in the leaching behavior of certain elements (i.e. As, Cd, Cr, Cu, Ni, Pb, Sb, Se and Zn) when IBA comes into contact with seawater. Such an investigation using seawater as leachant was not commonly carried out when investigating leaching behavior in IBA. The leaching tests were then carried out on the same IBA samples using DI water, as a comparison. Lower level of leaching was observed for Pb and Zn when seawater was used as the leachant. Cr and Sb showed significant cumulative release at Liquid-to-Solids (L/S) ratio 5 in the seawater column leaching. The influence of Dissolved Organic Carbon (DOC) on Cu leaching seems to decrease after L/S 2 when using seawater in the column test. Although the leaching behavior of IBA was affected when seawater was used, for the column test, there was no significant difference during the initial release when compared to DI water. The initial L/S fractions collected were important as the low L/S ratios represent the pore water concentration and the maximum output in an actual application. The results from this study would be useful for the future study on using IBA in marine applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Commercial test on uranium ore percolation leaching in Fuzhou uranium mine

    International Nuclear Information System (INIS)

    Cai Chunhui

    2002-01-01

    Commercial test on uranium ore percolation leaching was carried out according to ore characteristics of Fuzhou Uranium Mine and results from small test. Technological and economic indexes, such as leaching rate, acid consumption, leaching cycle, etc. are discussed. The general idea applying the test results to commercial production is presented, too

  4. Intercomparison of leach-testing methods and the effects of waste-form composition on test type and duration

    International Nuclear Information System (INIS)

    Harvey, K.B.; Jensen, C.D.

    1982-01-01

    Several leach-testing methods were evaluated for their relevance as scoping tests appropriate to proposed Canadian conditions for the disposal of high-level nuclear waste, and a static, terminated leach test was chosen. For a particular glass composition, methods in which the leachant was replenished gave apparent leach rates up to ten times less than did the static test. Under static leaching conditions, the leach rate of a number of sodium borosilicate glasses was observed to first rise and then fall with leaching time. This behavior is explained in terms of a pH change in the leachant, which is itself a function of the glass composition. The implications of these observations on glass compositions and on leach-testing methods that are relevant to the needs of final disposal are briefly discussed

  5. Comparative study of ageing, heat treatment and accelerated carbonation for stabilization of municipal solid waste incineration bottom ash in view of reducing regulated heavy metal/metalloid leaching.

    Science.gov (United States)

    Santos, Rafael M; Mertens, Gilles; Salman, Muhammad; Cizer, Özlem; Van Gerven, Tom

    2013-10-15

    This study compared the performance of four different approaches for stabilization of regulated heavy metal and metalloid leaching from municipal solid waste incineration bottom ash (MSWI-BA): (i) short term (three months) heap ageing, (ii) heat treatment, (iii) accelerated moist carbonation, and (iv) accelerated pressurized slurry carbonation. Two distinct types of MSWI-BA were tested in this study: one originating from a moving-grate furnace incineration operation treating exclusively household refuse (sample B), and another originating from a fluid-bed furnace incineration operation that treats a mixture of household and light industrial wastes (sample F). The most abundant elements in the ashes were Si (20-27 wt.%) and Ca (16-19 wt.%), followed by significant quantities of Fe, Al, Na, S, K, Mg, Ti, and Cl. The main crystalline substances present in the fresh ashes were Quartz, Calcite, Apatite, Anhydrite and Gehlenite, while the amorphous fraction ranged from 56 to 73 wt.%. The leaching values of all samples were compared to the Flemish (NEN 7343) and the Walloon (DIN 38414) regulations from Belgium. Batch leaching of the fresh ashes at natural pH showed that seven elements exceeded at least one regulatory limit (Ba, Cr, Cu, Mo, Pb, Se and Zn), and that both ashes had excess basicity (pH > 12). Accelerated carbonation achieved significant reduction in ash basicity (9.3-9.9); lower than ageing (10.5-12.2) and heat treatment (11.1-12.1). For sample B, there was little distinction between the leaching results of ageing and accelerated carbonation with respect to regulatory limits; however carbonation achieved comparatively lower leaching levels. Heat treatment was especially detrimental to the leaching of Cr. For sample F, ageing was ineffective and heat treatment had marginally better results, while accelerated carbonation delivered the most effective performance, with slurry carbonation meeting all DIN limits. Slurry carbonation was deemed the most

  6. A label-free colorimetric sensor for Pb2+ detection based on the acceleration of gold leaching by graphene oxide.

    Science.gov (United States)

    Shi, Xinhao; Gu, Wei; Zhang, Cuiling; Zhao, Longyun; Peng, Weidong; Xian, Yuezhong

    2015-03-14

    In this work, we developed a novel, label-free, colorimetric sensor for Pb(2+) detection based on the acceleration of gold leaching by graphene oxide (GO) at room temperature. Gold nanoparticles (AuNPs) can be dissolved in a thiosulfate (S2O3(2-)) aqueous environment in the presence of oxygen; however, the leaching rate is very slow due to the high activation energy (27.99 kJ mol(-1)). In order to enhance the reaction rate, some accelerators should be added. In comparison with the traditional accelerators (metal ions or middle ligands), we found that GO could efficiently accelerate the gold leaching reaction. Kinetic data demonstrate that the dissolution rate of gold in the Pb(2+)-S2O3(2-)-GO system is 5 times faster than that without GO at room temperature. In addition, the effects of surface modification and the nanoparticle size on the etching of AuNPs were investigated. Based on the GO-accelerated concentration-dependent colour changes of AuNPs, a colorimetric sensor for Pb(2+) detection was developed with a linear range from 0.1 to 20 μM and the limit of detection (LOD) was evaluated to be 0.05 μM. This colorimetric assay is simple, low-cost, label-free, and has numerous potential applications in the field of environmental chemistry.

  7. Evaluation of long-term behavior of concretes in high level waste repositories. An accelerated leaching test

    Directory of Open Access Journals (Sweden)

    Hidalgo, A.

    2004-04-01

    Full Text Available The present work describes an accelerated leaching method that with a rapid process allows to develop and evaluate cements for use in a nuclear disposal, and the understanding of the long term effects. The method has been developed to study the stability of cementitious materials in contact with bentonite, to be used in high level radioactivity waste repositories. Nitric acid has been selected to simulate in an accelerated way the pH decreasing produced when concrete is in contact with groundwaters.

    El presente trabajo describe un ensayo acelerado de lixiviación, que mediante un proceso rápido, permite desarrollar y evaluar cementos para su uso en instalaciones nucleares, y la comprensión de su comportamiento a largo plazo. El método se ha desarrollado para estudiar la estabilidad de materiales de base cemento, en contacto con bentonita, que serán utilizados en almacenamientos de resíduos radiactivos de alta actividad. Como agente lixiviante se seleccionó el ácido nítrico, con objeto de simular de forma acelerada, la disminución del pH que se produce cuando el hormigón entra en contacto con aguas subterráneas.

  8. NEXT GENERATION LEACHING TESTS FOR EVALUATING LEACHING OF INORGANIC CONSTITUENTS

    Science.gov (United States)

    In the U.S. as in other countries, there is increased interest in using industrial by-products as alternative or secondary materials, helping to conserve virgin or raw materials. The LEAF and associated test methods are being used to develop the source term for leaching or any i...

  9. Leach testing of SYNROC and glass samples at 85 and 200/degree/C

    International Nuclear Information System (INIS)

    Oversby, V.M.; Ringwood, A.E.

    1981-01-01

    Leach tests were conducted on 0.5 g disc samples of SYNROC and two glass types using distilled water at 85 and 200/degree/C. No leaching was detected for SYNROC at either temperature. Thus, the upper limit on leach rate for SYNROC is <0.005 g/m/sup 2/d. Waste glass PNL 76-68 had leach rates of 1.4 g/m/sup 2/ d at 85/degree/C and 8.9 g/m/sup 2/ d at 200/degree/C, while 73-1 glass frit had a leach rate of 41 g/m/sup 2/ d at 200/degree/C. The leach tests were repeated in the presence of rock powders. Again, no leaching was measurable for SYNROC. PNL 76-68 glass had leach rates between 4 and 23 g/m/sup 2/ d at 200/degree/C and 73-1 frit leached at rates between 29 and 176 g/m/sup 2/ d at 200/degree/C. Tests were also conducted on crushed glass samples (PNL 76-68, 100-200 /mu/m size fraction). Bulk leach rates were calculated based on measurement of Ca, Cs, and U in the leach solutions. The results of the leach tests show that SYNROC is several orders of magnitude more resistant to leaching than glass

  10. High Pressure Soxhlet Type Leachability testing device and leaching test of simulated high-level waste glass at high temperature

    International Nuclear Information System (INIS)

    Senoo, Muneaki; Banba, Tsunetaka; Tashiro, Shingo; Shimooka, Kenji; Araki, Kunio

    1979-11-01

    A High Pressure Soxhlet Type Leachability Testing Device (HIPSOL) was developed to evaluate long-period stability of high-level waste (HLW) solids. For simulated HLW solids, temperature dependency of the leachability was investigated at higher temperatures from 100 0 C to 300 0 C at 80 atm. Leachabilities of cesium and sodium at 295 0 C were 20 and 7 times higher than at 100 0 C, respectively. In the repository, the temperatures around solidified products may be hundred 0 C. It is essential to test them at such elevated temperatures. HIPSOL is also usable for accelerated test to evaluate long-period leaching behavior of HLW products. (author)

  11. Comparison of 200-liter and 40-milliliter leach tests

    International Nuclear Information System (INIS)

    Westsik, J.H. Jr.; Harvey, C.O.; Roberts, F.P.; Ross, W.A.; Thornhill, R.E.

    1982-01-01

    During the past year we have conducted a modified MCC-1 leach test on a 145 kg block of a cast cement waste form. The leach vessel was a 200 liter Teflon-lined drum and contained 97.5 liters of deionized water. The results of this large-scale leach test were compared with the results of standard MC-1 tests (40 ml) on smaller samples of the same waste form. The ratio of leachate volumes between the large and small scale tests was 2500 and the ratio of sample masses was 150,000. The cast cement samples for both tests contained plutonium-doped incinerator ash. The leachates from these tests were analyzed for both plutonium and the matrix elements. Evaluation of plutonium plateout in the large-scale test indicated that the majority of the plutonium leached from the samples deposits onto vessel walls and little ( -12 /sub M/) remains in solution. Comparison of elemental concentrations in the leachates indicates some differences up to 5X in the concentration in the large- and small-scale tests. The differences are attributed to differences in the solubilities of Ca, Si, and Fe at pH 11.5 and at pH 12.5. The higher pH observed for the large-scale test is a result of the larger quantities of sodium in the large block of cement

  12. Modelling inorganic and organic biocide leaching from CBA-amine (Copper–Boron–Azole) treated wood based on characterisation leaching tests

    Energy Technology Data Exchange (ETDEWEB)

    Lupsea, Maria [University of Toulouse, INSA, UPS, INP, LISBP, 135 Avenue de Rangueil, F–31077 Toulouse (France); INRA, UMR 792, F-31400 Toulouse (France); CNRS, UMR 5504, F-31400 Toulouse (France); Paris-Est University, CSTB — Scientific and Technical Centre for the Building Industry, DEE/Environment and Life Cycle Engineering Team, 24 Rue Joseph Fourier, F-38400 Saint Martin d' Hères (France); Tiruta-Barna, Ligia, E-mail: ligia.barna@insa-toulouse.fr [University of Toulouse, INSA, UPS, INP, LISBP, 135 Avenue de Rangueil, F–31077 Toulouse (France); INRA, UMR 792, F-31400 Toulouse (France); CNRS, UMR 5504, F-31400 Toulouse (France); Schiopu, Nicoleta [Paris-Est University, CSTB — Scientific and Technical Centre for the Building Industry, DEE/Environment and Life Cycle Engineering Team, 24 Rue Joseph Fourier, F-38400 Saint Martin d' Hères (France); Schoknecht, Ute [BAM — Federal Institute for Materials Research and Testing, Division 4.1, Unter den Eichen 87, 12205 Berlin (Germany)

    2013-09-01

    Numerical simulation of the leaching behaviour of treated wood is the most pertinent and less expensive method for the prediction of biocides' release in water. Few studies based on mechanistic leaching models have been carried out so far. In this work, a coupled chemistry-mass transport model is developed for simulating the leaching behaviour of inorganic (Cu, B) and organic (Tebuconazole) biocides from CBA-amine treated wood. The model is based on experimental investigations (lab-scale leaching tests coupled with chemical and structural analysis). It considers biocides' interactions with wood solid components and with extractives (literature confirmed reactions), as well as transport mechanisms (diffusion, convection) in different compartments. Simulation results helped at identifying the main fixation mechanisms, like (i) direct complexation of Cu by wood-phenolic and -carboxylic sites (and not via monoethanolamine; complex) on lignin and hemicellulose and strong dependence on extractives' nature, (ii) pH dependent binding of tebuconazole on polarized -OH moieties on wood. The role of monoethanolamine is to provide a pore-solution pH of about 7.5, when copper solubility is found to be weakest. The capability of the developed model to simulate the chemical and transport behaviour is the main result of this study. Moreover, it proved that characterization leaching tests (pH dependency and dynamic tests), combined with appropriate analytical methods are useful experimental tools. Due to its flexibility for representing and simulating various leaching conditions, chemical-transport model developed could be used to further simulate the leaching behaviour of CBA treated wood at larger scales. - Highlights: • Biocide and extractives leaching from ammonia-CBA treated wood were modelled. • The chemical-transport model identifies the main fixation/solubilisation mechanisms. • The model describes well the results of equilibrium and dynamic leaching

  13. Comparison of leaching tests and study of leaching mechanisms

    International Nuclear Information System (INIS)

    Amarantos, S.G.; Papadokostaki, K.G.; Petropoulos, J.H.

    1985-10-01

    The present work is concerned first with the study of certain aspects of the leaching kinetics of Cs + and Sr ++ embedded in cement, as Cs 2 SO 4 and SrSO 4 , and in particular: (a) the comparative evaluation of leaching in (i) stagnant, (ii) stirred and (iii) continuously flowing (modified Soxhlet) water, (b) the effect of atmospheric CO 2 on elution, (c) the effect of temperature changes during leaching. Secondly, model kinetic studies were carried out using cellulose acetate incorporating SrSO 4 , CaSO 4 or NaCl. The main results obtained were: (1) Cs leaching rates were not significantly affected by the leaching method or by the presence of atmospheric CO 2 . The embedded Cs exists in relatively easily leachable and less rapidly leachable (most probably located within the gel regions) forms. (2) Elution of Sr is retarded by stagnant and infrequently renewed leachant (method (i)) and by the presence of atmospheric CO 2 ; leaching method (iii), which tends to minimize both of these effects, gave the highest elution rates. (3) The observed elution kinetics in the case of cellulose acetate-CaSO 4 or SrSO 4 conform to the Higuchi model, but a more elaborate theory is needed for the cellulose acetate-NaCl system. (author)

  14. Technique for in situ leach simulation of uranium ores

    International Nuclear Information System (INIS)

    Grant, D.C.; Seidel, D.C.; Nichols, I.L.

    1985-01-01

    In situ uranium mining offers the advantages of minimal environmental disturbance, low capital and operating costs, and reduced mining development time. It is becoming an increasingly attractive mining method for the recovery of uranium from secondary ore deposits. In order to better understand the process, a laboratory technique was developed and used to study and simulate both the chemical and physical phenomena occurring in ore bodies during in situ leaching. The laboratory simulation technique has been used to determine effects of leaching variables on permeability, uranium recovery, and post-leach aquifer restoration. This report describes the simulation system and testing procedure in sufficient detail to allow the construction of the system, and to perform the desired leaching tests. With construction of such a system, in situ leaching of a given ore using various leach conditions can be evaluated relatively rapidly in the laboratory. Not only could optimum leach conditions be selected for existing ore bodies, but also exploitation of new ore bodies could be accelerated. 8 references, 8 figures, 2 tables

  15. Leach testing of simulated ion-exchange resin waste solidified in cement

    International Nuclear Information System (INIS)

    Muurinen, A.K.; Uotila, P.I.; Ovaskainen, R.M.

    Leach tests were carried out on ion-exchange resins solidified in cement. Three product mixtures, two isotopes and four leachants at two temperatures, were tested. The increase of resin content increased the leaching of Cs-137; the effect of silix admixture was negligible. The type of the leachant has a stronger influence on Co-60 than on Cs-137. The increase of temperature usually also increased leaching. (author)

  16. Long term leaching of silicate systems: testing procedure, actinides behaviour and mechanism

    International Nuclear Information System (INIS)

    Louwrier, K.; Matzke, H.; Ray, I.; Thiele, H.; Scheffler, K.; Riege, U.

    1977-06-01

    High-level waste borosilicate glasses and medium-level waste cement products have been leached with various aqueous solutions at ambient temperature. The leach rates of americium and plutonium are determined as well as the behaviour of the actinides in the boundary surface glass/leachant and in the leachant itself. Methods like light-scattering photometry and differential refractometry, molecular filtration, scanning electron microscopy and α-spectrometry of the energy-loss of α-particles in thin layers have been applied. From the experimental results a general model for the leaching mechanism has been established. A critical review of leach test procedures is accomplished aiming at the improvement of common tests with respect to the extrapolation of the obtained leach test data to final disposal safety considerations. (orig.) [de

  17. Investigation of a precise static leach test for the testing of simulated nuclear waste materials

    International Nuclear Information System (INIS)

    Kingston, H.M.; Cronin, D.J.; Epstein, M.S.

    1984-01-01

    The precision of the nuclear waste static leach test was evaluated using controlled experimental conditions and homogeneous glass materials. The majority of the leachate components were subjected to simultaneous multielement DCP analysis. The overall precision of the static leach test is determined by the summation of random effects caused by: variance in the experimental conditions of the leaching procedure; inhomogeneity of the material to be leached; and variance of the analytical techniques used to determine elemental concentrations in the leachate. In this study, strict control of key experimental parameters was employed to reduce the first source of variance. In addition, special attention to the preparation of glass samples to be tested assured a high degree of homogeneity. Described here are the details of the reduction of these two sources of variance to a point where the overall test precision is limited by that of the analysis step. Of the elements determined - B, Ba, Ca, Cs, Mo, Na, Si, Sr, and Zn - only Ca and Zn exhibited replicate imprecision significantly greater than that observed in the analysis of the leachate solutions. The imprecision in the Zn was partially attributed to the non-reproducible adsorption onto the leach vessel walls during the 28 day test period. None of the other elements exhibited this behavior

  18. A European test of pesticide-leaching models: methodology and major recommendations

    NARCIS (Netherlands)

    Vanclooster, M.; Boesten, J.J.T.I.; Trevisan, M.; Brown, C.D.; Capri, E.; Eklo, O.M.; Gottesbüren, B.; Gouy, V.; Linden, van der A.M.A.

    2000-01-01

    Testing of pesticide-leaching models is important in view of their increasing use in pesticide registration procedures in the European Union. This paper presents the methodology and major conclusions of a test of pesticide-leaching models. Twelve models simulating the vertical one-dimensional

  19. Imouraren - uranium leaching tests and specificities with analcites

    International Nuclear Information System (INIS)

    Wattinne-Morice, A.; Belieres, M.

    2010-01-01

    Imouraren is a sedimentary uranium deposit (total > 150 000 tU, average U ~ 0.08 %), located in Niger (~ 100 km from Agadez). Uranium mineralization is trapped in sandstones and is widely oxidized (uranotyle, metatuyamunite), but a part remains reduced (pitchblende, uraninite). The sandstones have a peculiar mineralogical assemblage (analcite partly chloritized) which can affect uranium recovery. Several acid heap leaching tests have been completed to determine the most suitable process parameters. Microscopic studies and XRD analysis performed on fresh ore and on leached residue highlight the complex behavior of uranium and the associated mineralogical families during the tests. (author)

  20. Leaching test of bituminized waste and waste solidified by epoxy resin

    International Nuclear Information System (INIS)

    Yoshinaka, Kazuyuki; Sugaya, Atsushi; Onizawa, Toshikazu; Takano, Yugo; Kimura, Yukihiko

    2008-10-01

    About 30,000 bituminized waste drums and about 1800 drums of waste solidified by epoxy resin, generated from Tokai Reprocessing Plant, were stored in storage facilities. And study for disposal of these waste is performed. It was considered that radioactive nuclides and chemical components were released from these waste by contact of underground water, when disposed there waste. This paper is reported that result of leaching tests for these waste, done from 2003 to 2006. We've get precious knowledge and data, as follows. (1) In leaching tests for bituminized waste, it has detected iodine-129 peak, considered difficult too low energy gamma to detect. We've get data and knowledge of iodine-129 behavior first. Leached radioactivity for 50 days calculated by peak area was equal for about 40% and 100% of including radioactivity in bituminized waste sample. And we've get data of behavior of nitric acid ion and so on, important to study for disposal, in various condition of sample shape or leaching liquid temperature. (2) In leaching test for waste solidified by epoxy resin, we've get data of behavior of TBP, radionuclides and so on, important to study for disposal. Leached TBP was equal about 1% of including of sample. And we've get data of iodine-129 behavior, too. It was confirmed that leached iodine-129 was equal for about 60% and 100% of including sample, for 90 days. (author)

  1. Long-term leach testing of solidified radioactive waste forms (International Standard Publication ISO 6961:1982)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    Processes are developed for the immobilization of radionuclides by solidification of radioactive wastes. The resulting solidification products are characterized by strong resistance to leaching aimed at low release rates of the radionuclides to the environment. To measure this resistance to leaching of the solidified materials: glass, glass-ceramics, bitumen, cement, concrete, plastics, a long-term leach test is presented. The long-term leach test is aimed at: a) the comparison of different kinds or compositions of solidified waste forms; b) the intercomparison between leach test results from different laboratories on one product; c) the intercomparison between leach test results on products from different processes

  2. Investigation of the leaching behavior of lead in stabilized/solidified waste using a two-year semi-dynamic leaching test.

    Science.gov (United States)

    Xue, Qiang; Wang, Ping; Li, Jiang-Shan; Zhang, Ting-Ting; Wang, Shan-Yong

    2017-01-01

    Long-term leaching behavior of contaminant from stabilization/solidification (S/S) treated waste stays unclear. For the purpose of studying long-term leaching behavior and leaching mechanism of lead from cement stabilized soil under different pH environment, semi-dynamic leaching test was extended to two years to investigate leaching behaviors of S/S treated lead contaminated soil. Effectiveness of S/S treatment in different scenarios was evaluated by leachability index (LX) and effective diffusion coefficient (D e ). In addition, the long-term leaching mechanism was investigated at different leaching periods. Results showed that no significant difference was observed among the values of the cumulative release of Pb, D e and LX in weakly alkaline and weakly acidic environment (pH value varied from 5.00 to 10.00), and all the controlling leaching mechanisms of the samples immersed in weakly alkaline and weakly acidic environments turned out to be diffusion. Strong acid environment would significantly affect the leaching behavior and leaching mechanism of lead from S/S monolith. The two-year variation of D e appeared to be time dependent, and D e values increased after the 210 th day in weakly alkaline and weakly acidic environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Environmental Hazard Assessment of Jarosite Waste Using Batch Leaching Tests

    Directory of Open Access Journals (Sweden)

    M. Kerolli – Mustafa

    2018-01-01

    Full Text Available Jarosite waste samples from Trepça Zinc Industry in Kosovo were subjected to two batch leaching tests as an attempt to characterize the leaching behavior and mobility of minor and major elements of jarosite waste. To achieve this, deionized water and synthetic acidic rain leaching tests were employed. A two-step acidic treatment in microwave digestion system were used to dissolve jarosite waste samples, followed by determination of Al, Ag, As, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, P, Pb, S, Si, Sr, and Zn by inductively coupled plasma optical emission spectrometry (ICP-OES. The validation of the procedure was performed by the analysis of two geochemical reference materials, S JR-3 and S Jsy-1. Two toxicity leaching tests revealed a high metal releasing of Cd, Cu, Ni, Mn, Pb, Zn, and As, and the metal release risk for these elements is still very high due the low pH and acid rain. The statistical analysis showed useful data information on the relationship between elements in jarosite samples in two different extraction conditions (deionized water and synthetic acid rain.

  4. EFRT M-12 Issue Resolution: Caustic-Leach Rate Constants from PEP and Laboratory-Scale Tests

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Rassat, Scot D.; Eslinger, Paul W.; Aaberg, Rosanne L.; Aker, Pamela M.; Golovich, Elizabeth C.; Hanson, Brady D.; Hausmann, Tom S.; Huckaby, James L.; Kurath, Dean E.; Minette, Michael J.; Sundaram, S. K.; Yokuda, Satoru T.

    2010-01-01

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes” of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. The work described in this report addresses caustic leaching under WTP conditions, based on tests performed with a Hanford waste simulant. Because gibbsite leaching kinetics are rapid (gibbsite is expected to be dissolved by the time the final leach temperature is reached), boehmite leach kinetics are the main focus of the caustic-leach tests. The tests were completed at the laboratory-scale and in the PEP, which is a 1/4.5-scale mock-up of key PTF process equipment. Two laboratory-scale caustic-leach tests were performed for each of the PEP runs. For each PEP run, unleached slurry was taken from the PEP caustic-leach vessel for one batch and used as feed for both of the corresponding laboratory-scale tests.

  5. Leach and EP [extraction procedure] toxicity tests on grouted waste from Tank 106-AN

    International Nuclear Information System (INIS)

    Serne, R.J.; Martin, W.J.; Lokken, R.O.; LeGore, V.L.; Lindenmeier, C.W.; Martin, P.F.C.

    1989-09-01

    Pacific Northwest Laboratory is conducting laboratory experiments to produce leach rate data for various waste species that will be contained in grout at Hanford. In the work reported here, grout made from Tank 106-AN liquid waste was used to produce empirical leach rate data for several radionuclides ( 60 Co, 90 Sr, 99Tc, 129I, 137Cs, and 241 Am), stable major components (NO 3 - , NO 2 - , F, Cl, and Na), and trace metals (Cr, Mo, and Ni). Two types of tests were used to produce leach rate data: an intermittent replacement leach test (ANS 16.1 leach test) and a static leach test. Measured effective diffusivities of key species are as follows: 4 to 6 x 10 -8 cm 2 /sec for 99 Tc, 3 to 7 x 10 -8 cm 2 /sec for 129 I, 4 to 6 x 10 -9 cm 2 /sec for nitrate, and 6 to 7 x 10 -9 cm 2 /sec for nitrite. The leach indices of all species studied are above (more favorable than) the waste form criteria. The leach indices for 99 Tc and 129 I are 7.4 ± 1.2 and 7.6 ± 0.4, respectively, and are being further investigated in continuing studies of double-shell slurry feed grouts. An Extraction Procedure (EP) toxicity test was also conducted and the grouted water is considered nontoxic per this test protocol. 19 refs., 9 figs., 8 tabs

  6. Leaching of saltstone: Laboratory and field testing and mathematical modeling

    International Nuclear Information System (INIS)

    Grant, M.W.; Langton, C.A.; Oblath, S.B.; Pepper, D.W.; Wallace, R.M.; Wilhite, E.L.; Yau, W.W.F.

    1987-01-01

    A low-level alkaline salt solution will be a byproduct in the processing of high-level waste at the Savannah River Plant (SRP). This solution will be incorporated into a wasteform, saltstone, and disposed of in surface vaults. Laboratory and field leach testing and mathematical modeling have demonstrated the predictability of contaminant release from cement wasteforms. Saltstone disposal in surface vaults will meet the design objective, which is to meet drinking water standards in shallow groundwater at the disposal area boundary. Diffusion is the predominant mechanism for release of contaminants to the environment. Leach testing in unsaturated soil, at soil moisture levels above 1 wt %, has shown no difference in leach rate compared to leaching in distilled water. Field leach testing of three thirty-ton blocks of saltstone in lysimeters has been underway since January 1984. Mathematical models were applied to assess design features for saltstone disposal. One dimensional infinite-composite and semi-infinite analytical models were developed for assessing diffusion of nitrate from saltstone through a cement barrier. Numerical models, both finite element and finite difference, were validated by comparison of model predictions with the saltstone lysimeter results. Validated models were used to assess the long-term performance of the saltstone stored in surface vaults. The maximum concentrations of all contaminants released from saltstone to shallow groundwater are predicted to be below drinking water standards at the disposal area boundary. 5 refs., 11 figs., 5 tabs

  7. Single-pass continuous-flow leach test of PNL 76-68 glass: some selected Bead Leach I results

    International Nuclear Information System (INIS)

    Coles, D.G.

    1981-01-01

    A single-pass continuous-flow leach test of PNL 76-68 glass beads (7 mm dia) was concluded after 420 days of uninterrupted operation. Variables included in the experimental matrix were flow-rate, leachant composition, and temperature. Analysis was conducted on all leachate samples for 237 Np and 239 Pu as well as a number of nonradioactive elements. Results indicated that flow-rate and leachant systematically affected the leach rate, but only slightly. Temperature effects were significant. Plutonium leach rate was lower at higher temperature suggesting that Pu sorption onto the beads was enhanced at the higher temperature. The range of leach rates for all analyzed elements (except Pu), at both temperature, at all three flow rates, and with all three leachant compositions varied only three orders of magnitude. The range of variables used in this experiment covered those expected in many proposed repository environments. The preliminary interpretation of the results also indicated that matrix dissolution may be the dominant leaching mechanism, at least for Np in bicarbonate leachant. Regardless of the leaching mechanism the importance of this study is that it bounds the effects of repository environments when the ground water is oxidizing and when it doesn't reach the waste form until the waste has cooled to ambient rock temperature

  8. Filtration and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Shimskey, Rick W.; Billing, Justin M.; Buck, Edgar C.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Geeting, John GH; Hallen, Richard T.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Snow, Lanee A.; Swoboda, Robert G.

    2009-02-20

    A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.( ) The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP-RPP-WTP-467, eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste-testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan • Characterizing the homogenized sample groups • Performing parametric leaching testing on each group for compounds of interest • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on filtration/leaching tests performed on two of the eight waste composite samples and follow-on parametric tests to support aluminum leaching results from those tests.

  9. Filtration and Leach Testing for PUREX Cladding Sludge and REDOX Cladding Sludge Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Shimskey, Rick W.; Billing, Justin M.; Buck, Edgar C.; Casella, Amanda J.; Crum, Jarrod V.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Hallen, Richard T.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Swoboda, Robert G.

    2009-03-02

    A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan (Barnes and Voke 2006). The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Hanford Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP RPP WTP 467 (Fiskum et al. 2007), eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan. • Characterizing the homogenized sample groups. • Performing parametric leaching testing on each group for compounds of interest. • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on a filtration/leaching test performed using two of the eight waste composite samples. The sample groups examined in this report were the plutonium-uranium extraction (PUREX) cladding waste sludge (Group 3, or CWP) and reduction-oxidation (REDOX) cladding waste sludge (Group 4, or CWR). Both the Group 3 and 4 waste composites were anticipated to be high in gibbsite, thus requiring caustic leaching. WTP RPT 167 (Snow et al. 2008) describes the homogenization, characterization, and parametric leaching activities before benchtop filtration/leaching testing of these two waste groups. Characterization and initial parametric data in that report were used to plan a single filtration/leaching test using a blend of both wastes. The test focused on filtration testing of the waste and caustic leaching for aluminum, in the form

  10. Single-pass continuous-flow leach test of PNL 76-68 glass: some selected Bead Leach I results

    International Nuclear Information System (INIS)

    Coles, D.G.

    1981-01-01

    A single-pass continuous-flow leach test of PNL 76-68 glass beads (7 mm dia) was concluded after 420 days of uninterrupted operation. Variables included in the experimental matrix were flow-rate, leachant composition, and temperature. Analysis was conducted on all leachate samples for 237 Np and 239 Pu as well as a number of nonradioactive elements. Results indicated that flow-rate and leachant systematically affected the leach rate, but only slightly. Temperature effects were significant. Plutonium leach rate was lower at higher temperature suggesting that Pu sorption onto the beads was enhanced at the higher temperature. The range of leach rates for all analyzed elements (except Pu), at both temperatures, at all three flow rates, and with all three leachant compositions varied over only three orders of magnitude. The range of variables used in this experiment covered those expected in many proposed repository environments. The preliminary interpretation of the results aPPh 3 also reacted with Mn 2 (CO) 10 and Cp 2 Mo 2 (CO) 6 to give a variety of products at room temperature. A radical mechanism was suggested

  11. Statistical tests applied as quality control measures to leaching of nuclear waste glasses and in the evaluation of the leach vessel

    International Nuclear Information System (INIS)

    Bokelund, H.; Deelstra, K.

    1988-01-01

    Simple statistical tests, such as regression analysis and analysis of variance, have been applied to data obtained from leaching experiments carried out under various conditions of time and temperature. The precision and the accuracy of the overall leaching procedure were evaluated considering the short term within laboratory effects. The data originated from determinations of the mass losses of leached glass specimens and from measurements of the electrical conductivity and the pH of the leachants. The solution conductivity correlates highly with the normalized mass loss; hence it provides a consistency check on the measurements of the latter parameter. The overall relative precision of the leaching test method was found to be 5-12%, including the effects caused by inhomogeneity of the glass specimens. The conditions for the application of the teflon inserts often used in leaching devices have been investigated; a modified cleaning procedure is proposed to ascertain the absence of systematic errors by their repeated utilization (quality control). The operational limit of 190 0 C, as specified by the Materials Characterization Center, Richland, USA was confirmed experimentally. 8 refs.; 1 figure; 8 tabs

  12. Selection of a leaching test method for waste product conformity verification

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A., E-mail: isabel.lopes@cdtn.br, E-mail: tellocc@cdtn.br, E-mail: hauczmj@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  13. Selection of a leaching test method for waste product conformity verification

    International Nuclear Information System (INIS)

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A.

    2017-01-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  14. Leaching behaviour of hazardous waste under the impact of different ambient conditions.

    Science.gov (United States)

    Pecorini, Isabella; Baldi, Francesco; Bacchi, Donata; Carnevale, Ennio Antonio; Corti, Andrea

    2017-05-01

    The overall objective of this study is to provide an improved basis for the assessment of the leaching behaviour of waste marked as hazardous partly stabilised (European waste catalogue code 19 03 04 ∗ ). Four samples of hazardous partly stabilised waste were subjected to two leaching tests: up-flow column tests and batch equilibrium tests. The research was carried out in two directions: the first aims at comparing the results of the two experimental setups while the second aims at assessing the impact of different ambient conditions on the leaching behaviour of waste. Concerning this latter objective the effect of mesophilic temperature, mechanical constraints and acid environment were tested through column percolation tests. Results showed no significant differences between batch and column leaching test outcomes when comparing average concentrations calculated at a liquid to solid ratio of 10:1 l kg -1  TS. Among the tested ambient conditions, the presence of an acid environment (pH=4.5) accelerated the leaching process resulting in a higher cumulative released quantity measured on the majority of the investigated polluting substances. On the contrary, the effect of temperature and mechanical constraints seemed to not affect the process showing final contents even lower than values found for the standard test. This result was furthermore confirmed by the application of the principal component analysis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Kinetics of steel slag leaching: Batch tests and modeling

    International Nuclear Information System (INIS)

    De Windt, Laurent; Chaurand, Perrine; Rose, Jerome

    2011-01-01

    Reusing steel slag as an aggregate for road construction requires to characterize the leaching kinetics and metal releases. In this study, basic oxygen furnace (BOF) steel slag were subjected to batch leaching tests at liquid to solid ratios (L/S) of 10 and 100 over 30 days; the leachate chemistry being regularly sampled in time. A geochemical model of the steel slag is developed and validated from experimental data, particularly the evolution with leaching of mineralogical composition of the slag and trace element speciation. Kinetics is necessary for modeling the primary phase leaching, whereas a simple thermodynamic equilibrium approach can be used for secondary phase precipitation. The proposed model simulates the kinetically-controlled dissolution (hydrolysis) of primary phases, the precipitation of secondary phases (C-S-H, hydroxide and spinel), the pH and redox conditions, and the progressive release of major elements as well as the metals Cr and V. Modeling indicates that the dilution effect of the L/S ratio is often coupled to solubility-controlled processes, which are sensitive to both the pH and the redox potential. A sensitivity analysis of kinetic uncertainties on the modeling of element releases is performed.

  16. Equilibrium leach testing of Magnox swarf and sludge

    International Nuclear Information System (INIS)

    Amin, A.; Angus, M.J.; Kirkham, I.A.; Tyson, A.

    1988-10-01

    A static equilibrium leach test has been developed to simulate repository conditions after ground water has penetrated the near field barrier. The repository components - waste, matrix and backfill - have been equilibrated with water for up to one year. Leachates were analysed for U, Pu, Np 237 , Am 241 , Cs 137 , Sr 90 , Tc 99 , I 129 and C 14 . Results are presented for leaching from Magnox fuel cladding wastes using a combination of matrices, backfills and atmospheric conditions. The equilibrium concentrations were generally very low and have been compared with the concentration of each isotope in drinking water that would give an adult an annual effective dose equivalent of 0.1mSv. (author)

  17. Equilibrium leach testing of Magnox swarf and sludge

    International Nuclear Information System (INIS)

    Amin, A.; Angus, M.J.; Kirkham, I.A.; Tyson, A.

    1987-10-01

    A static equilibrium leach test has been developed to simulate repository conditions after ground water has penetrated the near field barrier. The repository components - waste, matrix and backfill - have been equilibrated with water for up to one year. Leachates were analysed for U, Pu, Np 237 , Am 241 , Cs 137 , Sr 90 , Tc 99 , I 129 and C 14 . Results are presented for leaching from Magnox fuel cladding wastes using a combination of matrices, backfills and atmospheric conditions. The equilibrium concentrations were generally very low and have been compared with the concentration of each isotope in drinking water that would give an adult an annual effective dose equivalent of 0.1mSv. (author)

  18. The theory and method of two-well field test for in-situ leaching uranium

    International Nuclear Information System (INIS)

    Yao Yixuan; Huo Jiandang; Xiang Qiulin; Tang Baobin

    2007-01-01

    Because leaching area in field test for in-situ leaching uranium is not accounted exactly, the reliability of obtaining parameters by calculating can not be ensured, and the whole test needs a long time and great investment. In two-well field test, lixiviant is injected from one well, pregnant solution is pumped out from the other, flow rate of the production well is more than that of the injection well, and uranium is not recoveried. In the case of keeping invariable ratio of pumping capacity to injecting capacity during the testing process, leaching area is not variable, can be exactly calculated. The full field test needs six months to one year. Two-well test is a scientific, rapid, minimal spending field test method, and is widely used in Commonwealth of Independent States. (authors)

  19. Leach tests on grouts made with actual and trace metal-spiked synthetic phosphate/sulfate waste

    International Nuclear Information System (INIS)

    Serne, R.J.; Martin, W.J.; LeGore, V.L.; Lindenmeier, C.W.; McLaurine, S.B.; Martin, P.F.C.; Lokken, R.O.

    1989-10-01

    Pacific Northwest Laboratory conducted experiments to produce empirical leach rate data for phosphate-sulfate waste (PSW) grout. Effective diffusivities were measured for various radionuclides ( 90 Sr, 99 Tc, 14 C, 129 I, 137 Cs, 60 Co, 54 Mn, and U), stable major components (NO 3 - , SO 4 2- , H 3 BO 3 , K and Na) and the trace constituents Ag, As, Cd, Hg, Pb, and Se. Two types of leach tests were used on samples of actual PSW grout and synthetic PSW grout: the American Nuclear Society (ANS) 16.1 intermittent replacement leach test and a static leach test. Grout produced from both synthetic and real PSW showed low leach rates for the trace metal constituents and most of the waste radionuclides. Many of the spiked trace metals and radionuclides were not detected in any leachates. None of the effluents contained measurable quantities of 137 Cs, 60 Co, 54 Mn, 109 Cd, 51 Cr, 210 Pb, 203 Hg, or As. For those trace species with detectable leach rates, 125 I appeared to have the greatest leach rate, followed by 99 Tc, 75 Se, and finally U, 14 C, and 110m Ag. Leach rates for nitrate are between those for I and Tc, but there is much scatter in the nitrate data because of the very low nitrate inventory. 32 refs., 6 figs., 15 tabs

  20. Use of test results from the percolation leaching test (TS3) in the framework of the Construction Products Directive

    Energy Technology Data Exchange (ETDEWEB)

    Van Zomeren, A.; Dijkstra, J.J. [ECN Environment and Energy Engineering, Petten (Netherlands); Mesman, M.; Spijker, J. [National Institute for Public Health and the Environment RIVM, Bilthoven (Netherlands); Eikelboom, R. [Ministry of Infrastructure and Environment IenM, Den Haag (Netherlands)

    2013-10-15

    The enforcement of the European Construction Products Directive (and the more actual Construction Products Regulation) has led to the development of European harmonised standards for assessment of the emission of 'dangerous substances' from construction materials. According to Basic Working Requirement (BWR) number 3, the emissions from construction products to soil and groundwater should not have an unacceptable impact on the environmental quality over the life cycle of the product. In this paper the technical needs and boundary conditions of leaching tests to obtain meaningful and reliable test results are explained. Although this paper will not go into detail on 'impact assessment' and the resulting development of regulatory criteria, we will show that the technical needs and boundary conditions of a test are to some extent dependent on what type of information is needed by regulators for environmental impact assessment. This short paper focuses on explaining the principles of testing leaching behaviour of aggregates, and briefly explains the leaching of size reduced and non-size reduced particles. It provides information for the actual discussions on size reduction before leaching tests.

  1. Development of an accelerated test for Internal Sulfate Attack study

    Directory of Open Access Journals (Sweden)

    Khelil Nacim

    2014-04-01

    Full Text Available Internal Sulfate Attack (ISA is a pathology that occurs under certain conditions in concrete having undergone heating above 70 °C at early age (through heating in pre-casting industry or due to hydration in large concrete parts. This reaction deemed very slow, numerous methods to speed up reactions leading to delayed ettringite formation have been developed. These methods are all based on the material damage. Another type of test is currently under development. It is based on rehabilitation techniques such as electrochemical chloride extraction (ECE in order to accelerate the leaching of alkalis that could be one of the triggers of the pathology. The study presented in this paper focused on concrete specimens prepared from cement (CEM I 52.5 N enriched with Na2SO4. These concretes have undergone a heat treatment typical of those used in precast plants (up to 24 hours with a maximum temperature of 80 °C. Various paths were explored for the development of the accelerated test. The first results showed that it was necessary to use a removable titanium anode ruthenium anode instead of stainless steel embedded in the concrete. Then tests with de-ionized water as the solute to the cathode did not accelerate the onset of expansions. The experiment has been modified and potassium carbonate was added to the solution. This modification didn’t show any significant improvement, and other experiments are being carried out to explain this result.

  2. Estimation of Cadmium uptake by tobacco plants from laboratory leaching tests.

    Science.gov (United States)

    Marković, Jelena P; Jović, Mihajlo D; Smičiklas, Ivana D; Šljivić-Ivanović, Marija Z; Smiljanić, Slavko N; Onjia, Antonije E; Popović, Aleksandar R

    2018-03-21

    The objective of the present study was to determine the impact of cadmium (Cd) concentration in the soil on its uptake by tobacco plants, and to compare the ability of diverse extraction procedures for determining Cd bioavailability and predicting soil-to-plant transfer and Cd plant concentrations. The pseudo-total digestion procedure, modified Tessier sequential extraction and six standard single-extraction tests for estimation of metal mobility and bioavailability were used for the leaching of Cd from a native soil, as well as samples artificially contaminated over a wide range of Cd concentrations. The results of various leaching tests were compared between each other, as well as with the amounts of Cd taken up by tobacco plants in pot experiments. In the native soil sample, most of the Cd was found in fractions not readily available under natural conditions, but with increasing pollution level, Cd amounts in readily available forms increased. With increasing concentrations of Cd in the soil, the quantity of pollutant taken up in tobacco also increased, while the transfer factor (TF) decreased. Linear and non-linear empirical models were developed for predicting the uptake of Cd by tobacco plants based on the results of selected leaching tests. The non-linear equations for ISO 14870 (diethylenetriaminepentaacetic acid extraction - DTPA), ISO/TS 21268-2 (CaCl 2 leaching procedure), US EPA 1311 (toxicity characteristic leaching procedure - TCLP) single step extractions, and the sum of the first two fractions of the sequential extraction, exhibited the best correlation with the experimentally determined concentrations of Cd in plants over the entire range of pollutant concentrations. This approach can improve and facilitate the assessment of human exposure to Cd by tobacco smoking, but may also have wider applicability in predicting soil-to-plant transfer.

  3. Leach test of six 192-iridium pellets based on the IAEA 'special form' test procedures

    International Nuclear Information System (INIS)

    Gordon, G.; Gerdingh, R.

    1981-07-01

    The designation 'special form' may be applied to indispersible solid radioactive material if the material meets the requirements of the tests described in the International Atomic Energy Agency Regulations for the Safe Transport of Radioactive Type Materials. This report presents the procedures and results of a leach test performed as specified in the regulations on 6 'as received' active 192-iridium pellets. Mechanical tests were not carried out prior to or following the leach test. The activity of each of the first 6 water baths was found to be between 2.3 and 12.6 μCi, (8.5 x 10 4 and 4.7 x 10 5 Bq) and of the second 6, between 1.3 to 6.0 μCi, (4.8 x 10 4 to 2.2 x 10 5 Bq) thus exceeding the allowable limit

  4. The effects of temperature on the leaching behavior of cement waste forms: The cement/sodium sulfate system

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Pietrzak, R.; Heiser, J.; Franz, E.M.; Colombo, P.

    1989-10-01

    The leaching mechanisms of simulated low-level radioactive waste forms are being determined as support for development of an accelerated leach test. Two approaches are being used: (1) comparisons of leaching data with results of a model that describes diffusion from a finite cylinder, and (2) observation of the leaching process at temperatures between 20 degree C and 65 degree C. To provide results that can be used for modeling, leaching at elevated temperatures must change neither the leaching mechanism nor the structural controls of leaching such as the porosity. Releases of 137 Cs, 85 Sr, calcium, sodium and potassium from portland cement containing sodium sulfate, as a simulated evaporator sludge, have been determined under a variety of experimental conditions. Data from the leach tests were compared to model results for diffusion from the finite cylinder. While most leaching appears to be diffusion controlled, notable exceptions occur. For all samples activation energies ranging between 6 and 11 Kcal/mole have been calculated from the relationship of the effective diffusion coefficient to increasing temperature, close to the expected value of 5 Kcal/mole for diffusion. 11 refs., 4 figs., 2 tabs

  5. Use of leaching tests to quantify trace element release from waste to energy bottom ash amended pavements.

    Science.gov (United States)

    Roessler, Justin G; Townsend, Timothy G; Ferraro, Christopher C

    2015-12-30

    A series of roadway tests strips were paved on-site at a landfill in Florida, U.S. Waste to energy (WTE) bottom ash was used as a partial course aggregate replacement in a hot mix asphalt (HMA) and a Portland cement concrete (PCC) pavement, along with control HMA and PCC sections. This allowed for a comparison of the relative degree of leaching between both materials (HMA and PCC) as well as between the ash-amended and control pavements. Batch and monolithic tank leaching tests were conducted on the pavements. Testing of the PCC samples demonstrated that Mo and Al were elevated above regulatory thresholds for both the control and ash amended samples. Further leach testing demonstrated that the release of Mo was likely from the PCC and not a result of the inclusion of the BA into pavement. Batch leach testing of ash-amended HMA samples revealed Sb as a constituent of potential concern. The results of the monolith leaching test displayed leaching of Sb within the same order of magnitude as the regulatory threshold. Calculation of the leachability index (LI) for Sb found that it would have limited mobility when incorporated in the HMA matrix. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Measurement of leach rates: a review

    International Nuclear Information System (INIS)

    Mendel, J.E.

    1982-01-01

    A historical perspective of the techniques that can be used to measure the leach rate of radioactive waste forms is presented. The achievement of leach rates that are as low as possible has been an important goal ever since the development of solidification processes for liquid radioactive wastes began in the 1950's. Leach tests can be divided into two major categories, dynamic and static, based on whether or not the leachant in contact with the test specimen is changed during the course of the test. Both types of tests have been used extensively. The results of leach tests can be used to compare waste forms, and that has been a major purpose of leach data heretofore; increasingly, however, the data now are needed for predicting long-term leaching behavior during geologic disposal. This requirement is introducing new complexities into leach testing methodology. 3 figures, 2 tables

  7. Characterization and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

    International Nuclear Information System (INIS)

    Fiskum, Sandra K.; Buck, Edgar C.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Hubler, Timothy L.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; Lumetta, Gregg J.; MacFarlan, Paul J.; McNamara, Bruce K.; Peterson, Reid A.; Sinkov, Sergey I.; Snow, Lanee A.; Swoboda, Robert G.

    2008-01-01

    This report describes processing and analysis results of boehmite waste type (Group 5) and insoluble high Cr waste type (Group 6). The sample selection, compositing, subdivision, physical and chemical characterization are described. Extensive batch leach testing was conducted to define kinetics and leach factors of selected analytes as functions of NaOH concentration and temperature. Testing supports issue M-12 resolution for the Waste Treatment Plant

  8. Characterization and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Fiskum, Sandra K.; Buck, Edgar C.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Hubler, Timothy L.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; Lumetta, Gregg J.; MacFarlan, Paul J.; McNamara, Bruce K.; Peterson, Reid A.; Sinkov, Sergey I.; Snow, Lanee A.; Swoboda, Robert G.

    2008-07-10

    This report describes processing and analysis results of boehmite waste type (Group 5) and insoluble high Cr waste type (Group 6). The sample selection, compositing, subdivision, physical and chemical characterization are described. Extensive batch leach testing was conducted to define kinetics and leach factors of selected analytes as functions of NaOH concentration and temperature. Testing supports issue M-12 resolution for the Waste Treatment Plant.

  9. Tractor accelerated test on test rig

    Directory of Open Access Journals (Sweden)

    M. Mattetti

    2013-09-01

    Full Text Available The experimental tests performed to validate a tractor prototype before its production, need a substantial financial and time commitment. The tests could be reduced using accelerated tests able to reproduce on the structural part of the tractor, the same damage produced on the tractor during real life in a reduced time. These tests were usually performed reproducing a particular harsh condition a defined number of times, as for example using a bumpy road on track to carry out the test in any weather condition. Using these procedures the loads applied on the tractor structure are different with respect to those obtained during the real use, with the risk to apply loads hard to find in reality. Recently it has been demonstrated how, using the methodologies designed for cars, it is possible to also expedite the structural tests for tractors. In particular, automotive proving grounds were recently successfully used with tractors to perform accelerated structural tests able to reproduce the real use of the machine with an acceleration factor higher than that obtained with the traditional methods. However, the acceleration factor obtained with a tractor on proving grounds is in any case reduced due to the reduced speed of the tractors with respect to cars. In this context, the goal of the paper is to show the development of a methodology to perform an accelerated structural test on a medium power tractor using a 4 post test rig. In particular, several proving ground testing conditions have been performed to measure the loads on the tractor. The loads obtained were then edited to remove the not damaging portion of signals, and finally the loads obtained were reproduced in a 4 post test rig. The methodology proposed could be a valid alternative to the use of a proving ground to reproduce accelerated structural tests on tractors.

  10. EC static high-temperature leach test. Summary report of an European Community interlaboratory round robin

    International Nuclear Information System (INIS)

    Koennecke, R.; Kirsch, J.

    1985-01-01

    The results of an interlaboratory static high-temperature leach test conducted by the Commission of the European Communities in 1983 over a period of 9 months are compiled and statistically evaluated. A total of 12 laboratories - 10 from Member States of the EC and one from Finland and the USA - provided information concerning the test method and the analytical test results in the frame of a round robin test (RRT). All together these laboratories tested 366 waste from specimens of the borosilicate glass UK 209 containing simulated high-level radioactive waste. Leach tests were performed on the basis of the ''Document on the EC static high-temperature leach test method'' in autoclaves at leaching temperatures of 90 0 C, 110 0 C, 150 0 C, and 190 0 C over time periods of 3,7,14,28 and 56 days using dionized water as leachant. The resulting leachates were analysed for the elemental concentrations of Si,B,Sr,Nd and Cs by all laboratories and for the concentrations of the optional elements Na, Al,Ce,Mo,Cr,Fe,Li,Mg and Zn by some of the participating laboratories. Additionally, the F content of the blank leachates was analysed by all laboratories

  11. Leaching and soil/groundwater transport of contaminants from coal combustion residues

    International Nuclear Information System (INIS)

    Hjelmar, O.; Hansen, E.A.; Larsen, F.; Thomassen, H.

    1992-01-01

    In this project the results of accelerated laboratory leaching tests on coal fly ash and flue gas desulfurization (FGD) products from the spray dryer absorption process (SDA) were evaluated by comparison to the results of large scale lysimeter leaching tests on the same residues. The mobility of chromium and molybdenum - two of the kev contaminants of coal combustion residue leachates - in various typical soil types was investigated by batch and column methods in the laboratory. Some of the results were confirmed by field observations at an old coal fly ash disposal site and by a lysimeter attenuation test with coal fly ash leachate on a clayed till. A large number of groundwater transport models and geochemical models were reviewed, and two of the models (Gove-Stollenwerk and CHMTRNS) were modified and adjusted and used to simulate column attenuation tests performed in the laboratory. One of the models (Grove-Stollenwerk) was used to illustrate a recommended method of environmental impact assessment, using lysimeter leaching data and laboratory column attenuation data to describe the emission and migration of Mo from a coal fly ash disposal site

  12. PEP Run Report for Integrated Test A, Caustic Leaching in UFP-VSL-T01A, Oxidative Leaching in UFP-VSL-T02A

    International Nuclear Information System (INIS)

    Guzman-Leong, Consuelo E.; Bredt, Ofelia P.; Burns, Carolyn A.; Daniel, Richard C.; Su, Yin-Fong; Geeting, John G.H.; Golovich, Elizabeth C.; Josephson, Gary B.; Kurath, Dean E.; Sevigny, Gary J.; Smith, Dennese M.; Valdez, Patrick L.J.; Yokuda, Satoru T.; Young, Joan K.

    2009-01-01

    Pacific Northwest National Laboratory (PNNL) was tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed and constructed and operated as part of a plan to respond to issue M12, 'Undemonstrated Leaching Processes.'(a) The PEP, located in the Process Engineering Laboratory-West (PDLW) located in Richland, Washington, is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing.

  13. Leach testing of waste glasses under near-saturation conditions

    International Nuclear Information System (INIS)

    Strachan, D.M.; Grambow, B.

    1983-11-01

    Two waste glasses, MCC 76 to 68 and C31 to 3, were leached in deionized water and 0.001 M MgCl 2 for periods up to 158 days. At 57 days the gel layer was removed from some of the specimens and leaching continued for up to 100 days. Results from leaching in deionized water showed that the gel layer was not protective. Results from leaching in 0.001 M MgCl 2 are in good agreement with the predicted results obtained from the use of the PHREEQE geochemical code and with sepiolite [Mg 2 Si 3 O 6 (OH) 4 ] as the Mg-bearing precipitate. Both B and Si were predicted and observed to increase with increasing glass dissolution while maintaining sepiolite solubility. Both MCC 76 to 68 and C31 to 3 glasses showed increased leaching in 0.001 M MgCl 2 upon removal of the layer. This suggests a leaching mechanism whereby leaching is driven by the formation of an alteration product

  14. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1989-01-01

    The Product Consistency Test (PCT) is a glass leach test that was developed at the Savannah River Site (SRS) to routinely confirm the durability of nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a 7 day, crushed glass leach test in deionized water at 90 degree C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2--5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment

  15. Data report on leach tests of Pu-doped UO2 in PBB1 brine: Salt Repository Project

    International Nuclear Information System (INIS)

    Gray, W.J.

    1987-10-01

    This report provides results from a series of leach tests conducted using nonirradiated uranium dioxide (UO 2 ) doped with plutonium (Pu) to simulate the alpha activity of spent fuel specimens used in recent spent fuel leach tests. The purpose was to determine whether alpha radiation from the spent fuel could be responsible for uranium release values in spent fuel leach tests in salt brine that were at least 100 times greater than from similar tests with nonirradiated UO 2 pellets. The data in this data report are preliminary; they have been neither analyzed nor evaluated. 2 refs., 2 figs., 8 tabs

  16. PEP Run Report for Integrated Test A, Caustic Leaching in UFP-VSL-T01A, Oxidative Leaching in UFP-VSL-T02A

    Energy Technology Data Exchange (ETDEWEB)

    Guzman-Leong, Consuelo E.; Bredt, Ofelia P.; Burns, Carolyn A.; Daniel, Richard C.; Su, Yin-Fong; Geeting, John GH; Golovich, Elizabeth C.; Josephson, Gary B.; Kurath, Dean E.; Sevigny, Gary J.; Smith, Dennese M.; Valdez, Patrick LJ; Yokuda, Satoru T.; Young, Joan K.

    2009-12-04

    Pacific Northwest National Laboratory (PNNL) was tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed and constructed and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.”(a) The PEP, located in the Process Engineering Laboratory-West (PDLW) located in Richland, Washington, is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing.

  17. Pilot test of bacterial percolation leaching at Fuzhou uranium mine

    International Nuclear Information System (INIS)

    Fan Baotuan; Liu Jian; Jiang Yngqiong; Cai Chunhui; Jiang Lang; Zhou Renhua; Tong Changning; Zhang Hongli

    2006-01-01

    Total 18 t uranium ores of Fuzhou Uranium Mine packed in three or four columns in series were leached by bacterial percolation. The results show that without adding any other chemical oxidant such as sodium chlorate, the leaching rate measured by residue is 91.45%-94.48%, leaching time is 50-60 d, acid consumption is 6.17%-7.75%, and residue grade is 0.0149%-0.0208%. Compared with conventional percolation leaching process, the leaching rate is improved by 3%, leaching time is shorted by 26%, and acid consumption is saved by 34%. Accumulation pattern of ΣFe and F - in the process of leaching is discussed. Influence of F - on bacterial growth, regeneration of barren solution as well as correlative techniques are reviewed. (authors)

  18. Injection grout for deep repositories. Subproject 1: LowpH cementitious grout for larger fractures, leach testing of grout mixes and evaluation of the long-term safety

    International Nuclear Information System (INIS)

    Vuorinen, U.; Lehikoinen, J.; Imoto, Harutake; Yamamoto, Takeshi; Cruz Alonso, M.

    2005-10-01

    experimentally observed results. Leach rates or/and diffusion coefficients were calculated for Ca, K, S TOT , Si, Al, and Na using two different Fickian diffusion models. Amongst the tested new injection grouts the most promising characteristics (from chemical point of view) were found in the silica modified mixes when the content of silica fume was increased and ettringite-acceleration added. Two of these mixes, f63 and w1, had similar compositions; the ratio of silica fume to cement was 0.69 and only the type of cement used (Ordinary Portland Cement vs. Egyptian White Cement, respectively) was different. In addition to fulfilling the pH requirement of the leachate at the end of testing these two mixes had also demonstrated promising technical characteristics. Of these two mixes mix w1 showed better chemical characteristics. In saline leachate in the chosen equilibrium conditions the dissolved amounts were lower for K, SO 4 (almost an order of magnitude) and Si. Also in ALLMR at the end of diffusion testing the leachate contents of Na, K, Ca and Si were lower for mix w1. (orig.)

  19. Leaching of biocides used in façade coatings under laboratory test conditions.

    Science.gov (United States)

    Schoknecht, Ute; Gruycheva, Jana; Mathies, Helena; Bergmann, Hannelore; Burkhardt, Michael

    2009-12-15

    The European Biocidal Products Directive 98/8/EC requires a risk assessment concerning possible effects of active ingredients on the environment. Biocides can be leached from treated materials exposed to outdoor use. These emissions have to be estimated and evaluated during the authorization procedure. Different immersion and irrigation tests were performed to investigate leaching of biocides from façade coatings. Several marketed formulations of textured coatings and paints spiked with a mixture of commonly used active ingredients (OIT, DCOIT, IPBC, carbendazim, isoproturon, diuron, terbutryn, and Irgarol 1051) were investigated. The emission process can be described by time-dependent functions that depend on the test conditions. The results of all test procedures confirm that leachability is related to water solubility and n-octanol-water partition coefficient of the active ingredients and that leaching of biocides from façade coatings is mainly a diffusion controlled process. Other factors like the composition of the product, availability and transport of water, concentration of active ingredients in the coatings, as well as UV-exposure of the coatings influence biocide emissions.

  20. Small-scale and large-scale testing of photo-electrochemically activated leaching technology in Aprelkovo and Delmachik Mines

    Science.gov (United States)

    Sekisov, AG; Lavrov, AYu; Rubtsov, YuI

    2017-02-01

    The paper gives a description of tests and trials of the technology of heap gold leaching from rebellious ore in Aprelkovo and Delmachik Mines. Efficiency of leaching flowsheets with the stage-wise use of activated solutions of different reagents, including active forms of oxygen, is evaluated. Carbonate-peroxide solutions are used at the first stage of leaching to oxidize sulfide and sulfide-arsenide ore minerals to recover iron and copper from them. The second stage leaching uses active cyanide solutions to leach encapsulated and disperse gold and silver.

  1. "Turn-on" fluorescence detection of lead ions based on accelerated leaching of gold nanoparticles on the surface of graphene.

    Science.gov (United States)

    Fu, Xiuli; Lou, Tingting; Chen, Zhaopeng; Lin, Meng; Feng, Weiwei; Chen, Lingxin

    2012-02-01

    A novel platform for effective "turn-on" fluorescence sensing of lead ions (Pb(2+)) in aqueous solution was developed based on gold nanoparticle (AuNP)-functionalized graphene. The AuNP-functionalized graphene exhibited minimal background fluorescence because of the extraordinarily high quenching ability of AuNPs. Interestingly, the AuNP-functionalized graphene underwent fluorescence restoration as well as significant enhancement upon adding Pb(2+), which was attributed to the fact that Pb(2+) could accelerate the leaching rate of the AuNPs on graphene surfaces in the presence of both thiosulfate (S(2)O(3)(2-)) and 2-mercaptoethanol (2-ME). Consequently, this could be utilized as the basis for selective detection of Pb(2+). With the optimum conditions chosen, the relative fluorescence intensity showed good linearity versus logarithm concentration of Pb(2+) in the range of 50-1000 nM (R = 0.9982), and a detection limit of 10 nM. High selectivity over common coexistent metal ions was also demonstrated. The practical application had been carried out for determination of Pb(2+) in tap water and mineral water samples. The Pb(2+)-specific "turn-on" fluorescence sensor, based on Pb(2+) accelerated leaching of AuNPs on the surface of graphene, provided new opportunities for highly sensitive and selective Pb(2+) detection in aqueous media.

  2. Leaching From Biomass Gasification Residues

    DEFF Research Database (Denmark)

    Allegrini, Elisa; Boldrin, Alessio; Polletini, A.

    2011-01-01

    The aim of the present work is to attain an overall characterization of solid residues from biomass gasification. Besides the determination of chemical and physical properties, the work was focused on the study of leaching behaviour. Compliance and pH-dependence leaching tests coupled with geoche......The aim of the present work is to attain an overall characterization of solid residues from biomass gasification. Besides the determination of chemical and physical properties, the work was focused on the study of leaching behaviour. Compliance and pH-dependence leaching tests coupled...

  3. Next Generation of Leaching Tests

    Science.gov (United States)

    A corresponding abstract has been cleared for this presentation. The four methods comprising the Leaching Environmental Assessment Framework are described along with the tools to support implementation of the more rigorous and accurate source terms that are developed using LEAF ...

  4. Background information for the Leaching environmental Assessment Framework (LEAF) test methods

    Science.gov (United States)

    The U.S. Environmental Protection Agency Office of Resource Conservation and Recovery has initiated the review and validation process for four leaching tests under consideration for inclusion into SW-846: Method 1313 "Liquid-Solid Partitioning as a Function of Extract pH for Co...

  5. Effect of acid rain pH on leaching behavior of cement stabilized lead-contaminated soil.

    Science.gov (United States)

    Du, Yan-Jun; Wei, Ming-Li; Reddy, Krishna R; Liu, Zhao-Peng; Jin, Fei

    2014-04-30

    Cement stabilization is a practical approach to remediate soils contaminated with high levels of lead. However, the potential for leaching of lead out of these stabilized soils under variable acid rain pH conditions is a major environmental concern. This study investigates the effects of acid rain on the leaching characteristics of cement stabilized lead contaminated soil under different pH conditions. Clean kaolin clay and the same soil spiked with 2% lead contamination are stabilized with cement contents of 12 and 18% and then cured for 28 days. The soil samples are then subjected to a series of accelerated leaching tests (or semi-dynamic leaching tests) using a simulated acid rain leachant prepared at pH 2.0, 4.0 or 7.0. The results show that the strongly acidic leachant (pH ∼2.0) significantly altered the leaching behavior of lead as well as calcium present in the soil. However, the differences in the leaching behavior of the soil when the leachant was mildly acidic (pH ∼4.0) and neutral (pH ∼7.0) prove to be minor. In addition, it is observed that the lead contamination and cement content levels can have a considerable impact on the leaching behavior of the soils. Overall, the leachability of lead and calcium is attributed to the stability of the hydration products and their consequent influence on the soil buffering capacity and structure. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Leaching mechanisms

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Colombo, P.

    1984-01-01

    Sufficient data are lacking to provide a basis for adequately assessing the long term leaching behavior of solidified low level radioactive waste forms in their disposal environment. Although the release of radioactivity from a waste form to an aqueous environment is recognized to be due to one or more mechanisms such as diffusion, dissolution, corrosion or ion exchange, the leaching mechanisms and the factors which control the leaching behavior of waste forms are not fully understood. This study will determine the prevailing mechanisms for a variety of selected LLW solidification agents which are being considered for use by defense and commercial generators and which will cover the broadest possible number of mechanisms. The investigation will proceed by the postulation of mathematical models representative of the prevailing mechanism(s) and the use of statistically designed experiments to test the actual leaching behavior of laborattory samples against the postulated representations. Maximum use of existing leach data in the literature will be made by incorporating literature results into a computerized data base along with the experimental results generated in this task

  7. Long-term leaching behavior of vitrified high-level wastes

    International Nuclear Information System (INIS)

    Ishiguro, Katsuhiko; Sonobe, Hitoshi; Sasaki, Noriaki; Kashihara, Hidechiyo

    1985-01-01

    A long-term Soxhlet leaching test, long-term static leaching test, solubility evaluation test and actual-scale glass solid leaching test were carried out for simulated vitrified wastes. Under high flow-rate leachate conditions, the leaching of high-solubility substances such as B and Na increases almost linearly with time while that of Fe, Ni and rare earth metals strongly depends on their solubility. The overall leaching rate changes (tends to decrease) with time under static conditions. The elution or diffusion is the rate determining step in the earlier region of the leaching process while the solubilities of major components have greater effects in the latter region. The change of the dominant leaching mechanism is delayed more largely as the surface-area to leachate-volume (SA/V) ratio decreases. Actual-scale glass specimens showed almost the same leaching behaviors as small-scale ones. If cracks exist in glass solid, the leaching in them is slow causing little effects on the overall leaching rate. This may be due to the fact that solubility-dependent leaching is occuring in the cracks. The long-term static leaching observations were not satisfactorily explained by the MCC-3 type solubility test results. It is important to clarify the solubility-dependent leaching behaviors at large SA/V ratios. (Nogami, K.)

  8. Leaching of heavy metals from timah langat amang

    International Nuclear Information System (INIS)

    Shukri bin Othman

    1990-01-01

    Accelerated leaching studies of amang from Timah Langat for heavy metals showed that the material was rather stable. From almost 24 types of heavy metals contained in the material, the metal that leached out most was Al, followed by Pb, U, Cu, Mn, Fe, Mg, Y and La but at smaller quantities. The studies also showed that amang was very porous. The high seepage rate resulted in the solubilities of the metals not reaching equilibrium. In that situation, the leaching of heavy metals from amang was dependent on the seepage rate of water, the height of the material, the volume of water that seeped through and the solubility of the metals

  9. Execution of pilot tests for an uranium in situ leaching project

    International Nuclear Information System (INIS)

    Koch, H.J.

    1983-01-01

    Urangesellschaft is presently evaluating the technical and economic feasibility of an in situ leaching (ISL) project in Wyoming/USA. This report describes the basic technical principles for ISL-uranium projects and gives the reasons for conducting pilot tests prior to the construction of a commercial plant. It further describes the licensing requirements for an ISL-pilot plant and evaluates the results of the pilot tests. (orig.) [de

  10. Sustainable materials management using the Leaching Environmental Assessment Framework test methods

    Science.gov (United States)

    The need for improved leach tests became a priority due to adoption of more stringent air pollution control at U.S. coal-fired power plants resulting in the preferential partitioning of mercury (Hg) and other pollutants to fly ash and other air pollution control residues. Fly ash...

  11. Characterization, Leaching, and Filtration Testing for Tributyl Phosphate (TBP, Group 7) Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Matthew K.; Billing, Justin M.; Blanchard, David L.; Buck, Edgar C.; Casella, Amanda J.; Casella, Andrew M.; Crum, J. V.; Daniel, Richard C.; Draper, Kathryn E.; Fiskum, Sandra K.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Shimskey, Rick W.; Snow, Lanee A.; Swoboda, Robert G.

    2009-03-09

    .A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual waste-testing program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. The tributyl phosphate sludge (TBP, Group 7) is the subject of this report. The Group 7 waste was anticipated to be high in phosphorus as well as aluminum in the form of gibbsite. Both are believed to exist in sufficient quantities in the Group 7 waste to address leaching behavior. Thus, the focus of the Group 7 testing was on the removal of both P and Al. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

  12. Analysis of factors affecting the effect of stope leaching

    International Nuclear Information System (INIS)

    Xie Wangnan; Dong Chunming

    2014-01-01

    The industrial test and industrial trial production of stope leaching were carried out at Taoshan orefield of Dabu deposit. The results of test and trial production showed obvious differences in leaching rate and leaching time. Compared with industrial trial production of stope leaching, the leaching rate of industrial test was higher, and leaching time was shorter. It was considered that the blasting method and liquid arrangement were the main factors affecting the leaching rate and leaching time according to analysis. So we put forward the following suggestions: the technique of deep hole slicing tight-face blasting was used to reduce the yield of lump ores, the effective liquid arrangement methods were adopted to make the lixiviant infiltrating throughout whole ore heap, and bacterial leaching was introduced. (authors)

  13. The Next Linear Collider Test Accelerator

    International Nuclear Information System (INIS)

    Ruth, R.D.; Adolphsen, C.; Bane, K.

    1993-04-01

    During the past several years, there has been tremendous progress the development of the RF system and accelerating structures for a Next Linear Collider (NLC). Developments include high-power klystrons, RF pulse compression systems and damped/detuned accelerator structures to reduce wakefields. In order to integrate these separate development efforts into an actual X-band accelerator capable of accelerating the electron beams necessary for an NLC, we are building an NLC Test Accelerator (NLCTA). The goal of the NLCTA is to bring together all elements of the entire accelerating system by constructing and reliably operating an engineered model of a high-gradient linac suitable for the NLC. The NLCTA will serve as a testbed as the design of the NLC evolves. In addition to testing the RF acceleration system, the NLCTA is designed to address many questions related to the dynamics of the beam during acceleration. In this paper, we will report oil the status of the design, component development, and construction of the NLC Test Accelerator

  14. Leaching Mechanisms Program. Annual report

    International Nuclear Information System (INIS)

    Dougherty, D.; Colombo, P.; Doty, R.; Fuhrmann, M.

    1984-09-01

    The primary goal of this work is to determine the leaching mechanisms of a variety of matrix materials either in use or being considered for the solidification of low-level radioactive wastes by defense and commercial waste generators. Since this program is new and did not formally begin until May of FY 84, the results reported here are few and preliminary. Efforts were concentrated in the following activities: (1) The literature search for leaching data and proposed leaching models and mechanisms for low-level waste. (2) Data base development for leaching data being compiled from the literature and from the leaching experiments in this program. (3) The selection of solidification agents for the experimental part of the program. (4) Fabrication of leach samples and initiation of leach testing. 28 references, 9 figures, 4 tables

  15. Simple method of testing polymer leaching from thermoplastic sheets used for clear aligner

    Directory of Open Access Journals (Sweden)

    Shuvana Altaf Ansari

    2014-01-01

    Full Text Available Objective: With the increasing popularity of clear aligners, newer materials are introduced in the form of thermoplastic sheets. Long-term studies testing the biocompatibility of these sheets are not available. The purpose of this study is to provide a simple, yet effective method to evaluate their leaching potential. Materials and Methods: Using the oxidation reduction reaction taking place in the presence of two different concentrations of potassium permanganate, five different samples were tested. The sequence of colour change from purple to red to brown to yellow to clear was used to determine the amount of leaching. This is the result of a stoichiometric relation between the oxidizing agent and the reducing sample. Color changes were observed through naked eyes over a period of 24 h. Photographs were taken at 15 min, 8 h and 24 h using D-SLR1000 Canon camera. Photos were evaluated separately. Result: Diluted solution showed faster change in color, due to the lesser amount of reagent. 3A Medes (Korea was the first to leach, followed by CA (Scheu, Germany EVA (Endent Private Limited, Delhi, India, Ultradent (United States and Avac R (Jaypee, Kerela, India. Conclusion: "Do it yourself" test is a repeatable and reproducible method that can be modified and used in clinical practice as a chair side method.

  16. Accelerated life testing of spacecraft subsystems

    Science.gov (United States)

    Wiksten, D.; Swanson, J.

    1972-01-01

    The rationale and requirements for conducting accelerated life tests on electronic subsystems of spacecraft are presented. A method for applying data on the reliability and temperature sensitivity of the parts contained in a sybsystem to the selection of accelerated life test parameters is described. Additional considerations affecting the formulation of test requirements are identified, and practical limitations of accelerated aging are described.

  17. EFRT M12 Issue Resolution: Comparison of PEP and Bench-Scale Oxidative Leaching Results

    Energy Technology Data Exchange (ETDEWEB)

    Rapko, Brian M.; Brown, Christopher F.; Eslinger, Paul W.; Fountain, Matthew S.; Hausmann, Tom S.; Huckaby, James L.; Hanson, Brady D.; Kurath, Dean E.; Minette, Michael J.

    2009-08-14

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed and constructed and is to be operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP; and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP; vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to dissolve solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct steam injection to accelerate the leaching process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP1, the 19-M NaOH is added to un-concentrated waste slurry (3 to 8 wt% solids), while for leaching in UFP2, the slurry is concentrated to nominally

  18. Leaching of heavy metals from steelmaking slags

    International Nuclear Information System (INIS)

    Gomez, J. F. P.; Pino, C. G.

    2006-01-01

    Leaching tests with EAF and Ladle slags were performed, using a flow through tests and the standard batch test DIN 38414-S4. The previous method was used to simulate the leaching behaviour of steel slags under landfill. the chemical analysis of the leachates during this period shows, in general, for both types of slag, and increase of heavy metal releases with ageing. Standard test method DIN 38414-S4 was used to evaluate leachability of heavy metals by water in unprocessed slags. After more than one year of trials, slang samples submitted to these trials presented very low total leaching levels. The most extracted elements are calcium and magnesium. Nevertheless, in flow-though test, calcium and magnesium leached from solid slags are below 0.5% and all other metals below 0.1%. Leachates obtained with DIN 38414-S4 present, as expected, higher leaching values; however, these are inferior to 5% (Ca) and 1% (other elements). (Author) 12 refs

  19. Identification and testing of early indicators for N leaching from urine patches.

    Science.gov (United States)

    Vogeler, Iris; Cichota, Rogerio; Snow, Val

    2013-11-30

    Nitrogen leaching from urine patches has been identified as a major source of nitrogen loss under intensive grazing dairy farming. Leaching is notoriously variable, influenced by management, soil type, year-to-year variation in climate and timing and rate of urine depositions. To identify early indicators for the risk of N leaching from urine patches for potential usage in a precision management system, we used the simulation model APSIM (Agricultural Production Systems SIMulator) to produce an extensive N leaching dataset for the Waikato region of New Zealand. In total, nearly forty thousand simulation runs with different combinations of soil type and urine deposition times, in 33 different years, were done. The risk forecasting indicators were chosen based on their practicality: being readily measured on farm (soil water content, temperature and pasture growth) or that could be centrally supplied to farms (such as actual and forecast weather data). The thresholds of the early indicators that are used to forecast a period for high risk of N leaching were determined via classification and regression tree analysis. The most informative factors were soil temperature, pasture dry matter production, and average soil water content in the top soil over the two weeks prior to the urine N application event. Rainfall and air temperature for the two weeks following urine deposition were also important to fine-tune the predictions. The identified early indicators were then tested for their potential to predict the risk of N leaching in two typical soils from the Waikato region in New Zealand. The accuracy of the predictions varied with the number of indicators, the soil type and the risk level, and the number of correct predictions ranged from about 45 to over 90%. Further expansion and fine-tuning of the indicators and the development of a practical N risk tool based on these indicators is needed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Contaminant Leach Testing of Hanford Tank 241-C-104 Residual Waste

    Energy Technology Data Exchange (ETDEWEB)

    Cantrell, Kirk J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Snyder, Michelle M.V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Guohui [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Buck, Edgar C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-01

    Leach testing of Tank C-104 residual waste was completed using batch and column experiments. Tank C-104 residual waste contains exceptionally high concentrations of uranium (i.e., as high as 115 mg/g or 11.5 wt.%). This study was conducted to provide data to develop contaminant release models for Tank C-104 residual waste and Tank C-104 residual waste that has been treated with lime to transform uranium in the waste to a highly insoluble calcium uranate (CaUO4) or similar phase. Three column leaching cases were investigated. In the first case, C-104 residual waste was leached with deionized water. In the second case, crushed grout was added to the column so that deionized water contacted the grout prior to contacting the waste. In the third case, lime was mixed in with the grout. Results of the column experiments demonstrate that addition of lime dramatically reduces the leachability of uranium from Tank C-104 residual waste. Initial indications suggest that CaUO4 or a similar highly insoluble calcium rich uranium phase forms as a result of the lime addition. Additional work is needed to definitively identify the uranium phases that occur in the as received waste and the waste after the lime treatment.

  1. Chlorine-assisted leaching of Key Lake uranium ore

    International Nuclear Information System (INIS)

    Haque, K.E.

    1981-04-01

    Bench-scale chlorine-assisted leach tests were conducted on the Key Lake uranium ore. Leach tests conducted at 80 0 C on a slurry containing 50% solids during 10 hours of agitation gave the maximum extraction of uranium - 96% and radium-226 - 91%. Chlorine was added at 23.0 Kg Cl 2 /tonne of ore to maintain the leach slurry pH in the range of 1.5-1.0. To obtain residue almost free of radionuclides, hydrochloric acid leaches were conducted on the first stage leach residues. The second stage leach residue still was found to contain uranium - 0.0076% and radium-226 - 200 pCi/g of solids

  2. Accelerated cyclic corrosion tests

    Directory of Open Access Journals (Sweden)

    Prošek T.

    2016-06-01

    Full Text Available Accelerated corrosion testing is indispensable for material selection, quality control and both initial and residual life time prediction for bare and painted metallic, polymeric, adhesive and other materials in atmospheric exposure conditions. The best known Neutral Salt Spray (NSS test provides unrealistic conditions and poor correlation to exposures in atmosphere. Modern cyclic accelerated corrosion tests include intermittent salt spray, wet and dry phases and eventually other technical phases. They are able to predict the material performance in service more correctly as documented on several examples. The use of NSS should thus be restricted for quality control.

  3. Impact assessment of fly ash on ground water quality: An experimental study using batch leaching tests.

    Science.gov (United States)

    Dandautiya, Rahul; Singh, Ajit Pratap; Kundu, Sanghamitra

    2018-05-01

    The fly ash, generated at the coal-based thermal power plant, is always a cause of concern to environmentalists owing to its adverse impact on air, water and land. There exists a high environmental risk when it is disposed to the environment. Thus, two different type of fly ash samples (FA-1 and FA-2) have been considered in this study to examine the leaching potential of the elements magnesium, aluminium, silicon, calcium, titanium, vanadium, chromium, manganese, iron, nickel, cobalt, copper, zinc, arsenic, selenium, strontium, cadmium, barium and lead for different types of leachant. Toxicity characteristics leaching procedure and ASTM tests have been performed in the laboratory to simulate different natural leaching scenarios. Characterisation of samples have been done through X-ray diffraction and field emission gun scanning electron microscope. The effect of different liquid to solid ratios (i.e. 5, 10, 20 and 50) on the mobilisation of elements has been analysed. The results indicated that the maximum leaching of all elements occurred at a liquid to solid ratio of 5 except for arsenic, barium and silicon. The groundwater analysis has also been done to understand the actual effects of leachate. The elements presenting the highest leachability in the two fly ash samples under all tested conditions were magnesium, aluminium, silicon and calcium. It has been observed that calcium exhibits greater leaching effects than all other constituents. The study presented here has been found very useful for assessing contamination levels in groundwater owing to leaching effects of fly ash under different scenarios, which can be helpful to prevent spreading of the contaminants by efficient management of fly ash.

  4. Equilibrium leach testing of low level waste. Pt. 1

    International Nuclear Information System (INIS)

    Biddle, P.; Gale, M.D.; Godfrey, J.G.; Woodwark, D.R.

    1989-02-01

    The equilibrium leach test was developed to simulate the chemical conditions in a repository after water has penetrated the near field barriers. The principal components of the repository (the waste, backfill and canister simulant) are equilibrated with water under static conditions to simulate the very low water flows likely to be encountered in the repository. The water is sampled at various times over a 1-2 year period and analysed for radionuclides. Equilibrium leach testing has now been extended to low level wastes and this report describes the effects of different backfill compositions. Later reports will deal with the effects of other variables. A series of experiments have been conducted using four different backfills with ferric floc sludge wastes in both oxidising and reducing environments. The water was sampled at 1, 3, 6 and 12 months and analysed for actinides, fission and activation products and inactive components. It was demonstrated that the activities released depended on the nature of the backfill but not very much on the redox potential of the system. Whereas fission and activation products generally reached steady state values by three months, this was not so for the actinides which had not reached a steady value even after twelve months. Initial experiments using membrane filters indicated this was partly due to the presence of colloidal material in the leachates. Similar tests for the inactive components of the leachates did not show any significant colloidal contribution from these elements except for iron and this only in a few cases. The role of these materials cannot be precluded however, since the amounts required to interact with actinides would be very small and might be difficult to detect. (author)

  5. Basic leaching tests for pure beta long-lived emitters in radioactive wastes

    International Nuclear Information System (INIS)

    Murillo, R.; Almodovar, A.; Gonzalez de la Huebra, A.

    1995-09-01

    Specimens for the two first leaching stages were manufactured using samples of virgin resins saturated in simulated conditions. EPIFLOC 21H resin was 50% saturated with NaCl and DUOLITE ARM-9381 resin was 100% saturated with NaCl+H 3 BO 3 . Previously both resins were doped with Ni-63 and Sr-90. As far as the third leaching stage is concerning, samples of real resins from two Spanish nuclear power plants were used for manufacturing of leaching specimens. Because Sr-90 and Ni-63 radioactivity in these samples was not high enough to be detectable in leachate, samples were additionally loaded with Sr-90 and Ni-63 before mixing with cement. Leaching procedure was adapted to the French one (the same duration of leaching renewal steps and cumulative leaching time and also the same analytical preparation for chemical and radiochemical analysis). Specimens were hanged into leachant with nylon yarn and were surrounded by a leachant layer of 3 cm thickness. Additionally to Sr-90 and Ni-63, the main chemical elements present in cements used for manufacturing of specimens were analyzed in leachates from the two first leaching stages and the main gamma emitters present in the samples of real resins were analyzed in leachates from the third leaching stages. (Author)

  6. Leaching behaviour of incineration bottom ash in a reuse scenario: 12years-field data vs. lab test results.

    Science.gov (United States)

    Di Gianfilippo, Martina; Hyks, Jiri; Verginelli, Iason; Costa, Giulia; Hjelmar, Ole; Lombardi, Francesco

    2018-03-01

    Several types of standardized laboratory leaching tests have been developed during the past few decades to evaluate the leaching behaviour of waste materials as a function of different parameters, such as the pH of the eluate and the liquid to solid ratio. However, the link between the results of these tests and leaching data collected from the field (e.g. in disposal or reuse scenarios) is not always straightforward. In this work, we compare data obtained from an on-going large scale field trial, in which municipal solid waste incineration bottom ash is being tested as road sub-base material, with the results obtained from percolation column and pH-dependence laboratory leaching tests carried out on the bottom ash at the beginning of the test. The comparisons reported in this paper show that for soluble substances (e.g. Cl, K and SO 4 ), percolation column tests can provide a good indication of the release expected in the field with deviations usually within a factor of 3. For metals characterized by a solubility-controlled release, i.e. that depends more on eluate pH than the liquid to solid ratio applied, the results of pH-dependence tests describe more accurately the eluate concentration trends observed in the field with deviations that in most cases (around 80%) are within one order of magnitude (see e.g. Al and Cd). The differences between field and lab-scale data might be in part ascribed to the occurrence in the field of weathering reactions (e.g. carbonation) but also to microbial decomposition of organic matter that modifying leachate pH affect the solubility of several constituents (e.g. Ca, Ba and Cr). Besides, weathering reactions can result in enhanced adsorption of fulvic acids to iron/aluminum (hydr)oxides, leading to a decrease in the leaching of fulvic acids and hence of elements such as Cu, Ni and Pb that strongly depend on DOC leaching. Overall, this comparison shows that percolation column tests and pH-dependence tests can represent a reliable

  7. Method for evaluating leaching from LSA-III material

    International Nuclear Information System (INIS)

    Abe, H.; Satoh, K.; Ozaki, S.; Watabe, N.; Iida, T.; Akamatsu, H.

    1989-01-01

    The IAEA transport regulations are scheduled to be introduced in Japan. New regulations are supposed to be set forth for low specific activity (LSA) material and industrial packaging (IP) as solidified concentrated waste water should correspond to the LSA material. Solidified concentrated waste water should be transported in accordance with the new transport regulations which reflect the IAEA transport regulations. As one of the regulations for LSA material, the leaching test for LSA-III materials states that the radioactive loss due to leaching without the packaging should not exceed 0.1 A 2 when left in the water for 7 days. This test method is called Transport regulations hereafter. Since the test had not been conducted in Japan before now, there was no available data. Consequently, it is necessary to make an assessment on whether the current solidified concentrated waste water can satisfy the leaching amount of radioactive nuclide specified in the IAEA transport regulations. If the test is performed in accordance with the IAEA transport regulations, however, it is necessary to measure the amount of radioactive nuclide actually leached from the solidified concentrated waste water. Since the solidified concentrated waste water is put in a drum cam, it is necessary to prepare large-scale hot test equipment. In this study, therefore, the leaching test was conducted on the solidified concentrated waste water to propose the means of a leaching assessment which can be conducted with ordinary equipment to evaluate the leaching for assessment of the adaptability to IAEA transport regulations. In addition, the leaching test was performed in accordance with the IAEA method to examine the co-relation between the transport regulations and the IAEA method. Many test results have been reported for the IAEA method in Japan, which will be detailed later on

  8. Implementation of the Leaching Environmental Assessment Framework

    Science.gov (United States)

    New leaching tests are available in the U.S. for developing more accurate source terms for use in fate and transport models. For beneficial use or disposal, the use of the leaching environmental assessment framework (LEAF) will provide leaching results that reflect field condit...

  9. Effect of drying-wetting cycles on leaching behavior of cement solidified lead-contaminated soil.

    Science.gov (United States)

    Li, Jiang-Shan; Xue, Qiang; Wang, Ping; Li, Zhen-Ze; Liu, Lei

    2014-12-01

    Lead contaminated soil was treated by different concentration of ordinary Portland cement (OPC). Solidified cylindrical samples were dried at 40°C in oven for 48 h subsequent to 24h of immersing in different solution for one drying-wetting. 10 cycles were conducted on specimens. The changes in mass loss of specimens, as well as leaching concentration and pH of filtered leachates were studied after each cycle. Results indicated that drying-wetting cycles could accelerate the leaching and deterioration of solidified specimens. The cumulative leached lead with acetic acid (pH=2.88) in this study was 109, 83 and 71 mg respectively for solidified specimens of cement-to-dry soil (C/Sd) ratios 0.2, 0.3 and 0.4, compared to 37, 30, and 25mg for a semi-dynamic leaching test. With the increase of cycle times, the cumulative mass loss of specimens increased linearly, but pH of filtered leachates decreased. The leachability and deterioration of solidified specimens increased with acidity of solution. Increases of C/Sd clearly reduced the leachability and deterioration behavior. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Laboratory leach tests of phosphate/sulfate waste grout and leachate adsorption tests using Hanford sediment

    Energy Technology Data Exchange (ETDEWEB)

    Serne, R.J.; Martin, W.J.; McLaurine, S.B.; Airhart, S.P.; LeGore, V.L.; Treat, R.L.

    1987-12-01

    An assessment of the long-term risks posed by grout disposal at Hanford requires data on the ability of grout to resist leaching of waste species contained in the grout via contact with water that percolates through the ground. Additionally, data are needed on the ability of Hanford sediment (soil) surrounding the grout and concrete vault to retard migration of any wastes released from the grout. This report describes specific laboratory experiments that are producing empirical leach rate data and leachate-sediment adsorption data for Phosphate-Sulfate Waste (PSW) grout. The leach rate and adsorption values serve as inputs to computer codes used to forecast potential risk resulting from the use of ground water containing leached species. In addition, the report discusses other chemical analyses and geochemical computer code calculations that were used to identify mechanisms that control leach rates and adsorption potential. Knowledge of the controlling chemical and physical processes provides technical defensibility for using the empirical laboratory data to extrapolate the performance of the actual grout disposal system to the long time periods of interest. 59 refs., 83 figs., 18 tabs.

  11. Laboratory leach tests of phosphate/sulfate waste grout and leachate adsorption tests using Hanford sediment

    International Nuclear Information System (INIS)

    Serne, R.J.; Martin, W.J.; McLaurine, S.B.; Airhart, S.P.; LeGore, V.L.; Treat, R.L.

    1987-12-01

    An assessment of the long-term risks posed by grout disposal at Hanford requires data on the ability of grout to resist leaching of waste species contained in the grout via contact with water that percolates through the ground. Additionally, data are needed on the ability of Hanford sediment (soil) surrounding the grout and concrete vault to retard migration of any wastes released from the grout. This report describes specific laboratory experiments that are producing empirical leach rate data and leachate-sediment adsorption data for Phosphate-Sulfate Waste (PSW) grout. The leach rate and adsorption values serve as inputs to computer codes used to forecast potential risk resulting from the use of ground water containing leached species. In addition, the report discusses other chemical analyses and geochemical computer code calculations that were used to identify mechanisms that control leach rates and adsorption potential. Knowledge of the controlling chemical and physical processes provides technical defensibility for using the empirical laboratory data to extrapolate the performance of the actual grout disposal system to the long time periods of interest. 59 refs., 83 figs., 18 tabs

  12. Leaching of tritium from a cement composite

    International Nuclear Information System (INIS)

    Matsuzuru, Hideo; Ito, Akihiko

    1978-10-01

    Leaching of tritium from cement composites into an aqueous phase has been studied to evaluate the safety of incorporation of the tritiated liquid waste into cement. Leaching tests were performed by the method recommended by the International Atomic Energy Agency. The Leaching fraction was measured as functions of waste-cement ratio (Wa/C), temperature of leachant and curing time. The tritium leachability of cement in the long term test follows the order: alumina cement portland cement slag cement. The fraction of tritium leached increases with increasing Wa/C and temperature and decreasing curing period. A deionized water as a leachant gives a slightly higher leachability than synthetic sea water. The amount leached of tritium from a 200 l drum size specimen was estimated on the basis of the above results. (author)

  13. Accelerated test program

    Science.gov (United States)

    Ford, F. E.; Harkness, J. M.

    1977-01-01

    A brief discussion on the accelerated testing of batteries is given. The statistical analysis and the various aspects of the modeling that was done and the results attained from the model are also briefly discussed.

  14. Comparison of leaching tests to determine and quantify the release of inorganic contaminants in demolition waste

    International Nuclear Information System (INIS)

    Delay, Markus; Lager, Tanja; Schulz, Horst D.; Frimmel, Fritz H.

    2007-01-01

    The changes in waste management policy caused by the massive generation of waste materials (e.g. construction and demolition waste material, municipal waste incineration products) has led to an increase in the reuse and recycling of waste materials. For environmental risk assessment, test procedures are necessary to examine waste materials before they can be reused. In this article, results of column and lysimeter leaching tests having been applied to inorganic compounds in a reference demolition waste material are presented. The results show a good agreement between the leaching behaviour determined with the lysimeter unit and the column units used in the laboratory. In view of less time and system requirements compared to lysimeter systems, laboratory column units can be considered as a practicable instrument to assess the time-dependent release of inorganic compounds under conditions similar to those encountered in a natural environment. The high concentrations of elements in the seepage water at the initial stage of elution are reflected by the laboratory column leaching tests. In particular, authorities or laboratories might benefit and have an easy-to-use, but nevertheless reliable, method to serve as a basis for decision-making

  15. Leaching behavior of simulated high-level waste glass

    International Nuclear Information System (INIS)

    Kamizono, Hiroshi

    1987-03-01

    The author's work in the study on the leaching behavior of simulated high-level waste (HLW) glass were summarized. The subjects described are (1) leach rates at high temperatures, (2) effects of cracks on leach rates, (3) effects of flow rate on leach rates, and (4) an in-situ burial test in natural groundwater. In the following section, the leach rates obtained by various experiments were summarized and discussed. (author)

  16. Leaching studies of low-level radioactive waste forms

    International Nuclear Information System (INIS)

    Dayal, R.; Arora, H.; Clinton, J.C.; Milian, L.

    1985-01-01

    A research program has been under way at the Brookhaven National Laboratory to investigate the radionuclide release behavior of ion exchange bead resin waste solidified in Portland cement. An important aspect of this program is to develop and evaluate testing procedures and methodologies which enable the long-term performance evaluation of waste forms under simulated field conditions. Cesium and strontium release behavior using a range of testing procedures, including intermittent leachant flow conditions, has been investigated. For cyclic wet/dry leaching tests, extended dry periods tend to enhance the release of Cs and suppress the release of Sr. Under extended wet period leaching conditions, however, both Cs and Sr exhibit suppressed releases. In contrast, radionuclide releases observed under continuously saturated leaching conditions, as represented by conventional leaching tests, are significantly different. The relevance and aplicability of these laboratory data obtained under a wide range of leaching conditions to the performance evaluation of waste forms under anticipated field conditions is discussed. 12 refs., 9 figs., 3 tabs

  17. Leaching methods for conditioned radioactive waste

    International Nuclear Information System (INIS)

    Carpentiero, R.; Bienvenu, P.; Huebra, A. G. de la; Dale, C.; Grec, D.; Gallego, C.; Rodriguez, M.; Vanderlinden, F.; Voors, P. I.; Welbergen, J.; May, R.; Fays, J.

    2005-01-01

    The physico-chemical characterization of solidified, real or simulated, radioactive waste is essential in determining their long-term stability in conditions close to that which could be encountered during disposal. The evaluation or prediction of the performance of conditioned waste passes through many suitable studies and experiments, according to a documented qualification programme. In this respect the leaching test is among the first important techniques to evaluate the feasibility of a waste form and for comparing and selecting the best waste form. So the leaching behaviour of an immobilized radioactive waste is a relevant property to be studied. The objective of the present report is to collect and describe the most representative leaching methods used in international laboratories, mainly at European level, whether standard or standard-derived. In this instance the work is a summary of the Network knowledge and applications on leaching processes in order to exchange information and scientific and technical experiences in this respect. The focus is to express all the relevant parameters of the test and its field of application. all this background is the needed starting point to clarify the similarities and shortcomings of the methods used in the EN-TRAP laboratories and, subsequently, the possible equalities or differences which can be attributed to the characteristic parameters of the different type of wastes treated. In order to comprise the significance and the effects of the parameters involved in leaching phenomena, an initial discussion on leaching mechanisms and on achievable results is made in this document. The international standardised methods are summarised as being the origin for all the network leaching procedures. This work in a preliminary way represents a comparative review ordered to introduce an unique leaching procedure to be tested in an interlaboratory comparative exercise. Further the unique method would be a quick internal reference

  18. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1990-01-01

    The product consistency test (PCT) is a glass leach test developed at the Savannah River Site (SRS) to confirm the durability of radioactive nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a seven day, crushed glass leach test in deionized water at 90C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2-5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment. When the results of the two laboratories were compared to each other, the agreement was within 20%. Normalized concentrations for the nonradioactive and radioactive elements in the PCT leachates measured at both facilities indicated that the radionuclides were released from the glass slower than the major soluble elements in the glass. For both laboratories, the normalized releases for both glasses were in the general order Li ∼ B ∼ Na > Si > Cs - 137 > Sb - 125 < Sr - 90. The normalized releases for the major soluble elements and the final pH values in the tests with radioactive glass are consistent with those for nonradioactive glasses with similar compositions. This indicates that there was no significant effect of radiation on the results of the PCT

  19. Ultrasound-assisted HCl-NaCl leaching of lead-rich and antimony-rich oxidizing slag.

    Science.gov (United States)

    Zhang, Rong Liang; Zhang, Xiao Fei; Tang, Shu Zhen; Huang, Ai Dong

    2015-11-01

    Lead-rich and antimony-rich oxidizing slag was subjected to regular HCl-NaCl leaching, with the experimental conditions optimized under which ultrasound was introduced. After only 15 min of ultrasound-assisted leaching, the leaching rate of Sb resembled that after 45 min of regular leaching. Ultrasonic treatment considerably elevated the leaching rates of Sb and Pb, and shortened the leaching time. With the decrease of particle size, the leaching rate of Sb and Pb increased gradually. Especially, as the particle size of the slag was greater than 0.217 mm, the ultrasonic leaching effects of Sb and Pb were significantly higher than that of regular leaching effects. The temperature exhibited great effect on ultrasonic leaching performance. As the temperature increased, the leaching rates of Sb and Pb increased step by step. In case the temperature was higher than 85°C, the increasing speed of the leaching rates for Sb and Pb tended to be slow. Increasing ultrasonic power could augment the leaching rate or accelerate the procedure till the same leaching rate. However, since ultrasound failed to energize the formation of new reaction pathways, the maximum leaching rates of Sb and Pb were determined by their phase compositions rather than by ultrasonic field. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Carbon leaching from tropical peat soils and consequences for carbon balances

    Directory of Open Access Journals (Sweden)

    Tim Rixen

    2016-07-01

    Full Text Available Drainage and deforestation turned Southeast (SE Asian peat soils into a globally important CO2 source, because both processes accelerate peat decomposition. Carbon losses through soil leaching have so far not been quantified and the underlying processes have hardly been studied. In this study, we use results derived from nine expeditions to six Sumatran rivers and a mixing model to determine leaching processes in tropical peat soils, which are heavily disturbed by drainage and deforestation. Here we show that a reduced evapotranspiration and the resulting increased freshwater discharge in addition to the supply of labile leaf litter produced by re-growing secondary forests increase leaching of carbon by ~200%. Enhanced freshwater fluxes and leaching of labile leaf litter from secondary vegetation appear to contribute 38% and 62% to the total increase, respectively. Decomposition of leached labile DOC can lead to hypoxic conditions in rivers draining disturbed peatlands. Leaching of the more refractory DOC from peat is an irrecoverable loss of soil that threatens the stability of peat-fringed coasts in SE Asia.

  1. Construction and demolition waste: Comparison of standard up-flow column and down-flow lysimeter leaching tests.

    Science.gov (United States)

    Butera, Stefania; Hyks, Jiri; Christensen, Thomas H; Astrup, Thomas F

    2015-09-01

    Five samples of construction and demolition waste (C&DW) were investigated in order to quantify leaching of inorganic elements under percolation conditions according to two different experimental setups: standardised up-flow saturated columns (<4mm particle size) and unsaturated, intermittent down-flow lysimeters (<40mm particle size). While standardised column tests are meant primarily to provide basic information on characteristic leaching properties and mechanisms and not to reproduce field conditions, the lysimeters were intended to mimic the actual leaching conditions when C&DW is used in unbound geotechnical layers. In practice, results from standardised percolation tests are often interpreted as estimations of actual release from solid materials in percolation scenarios. In general, the two tests yielded fairly similar results in terms of cumulative release at liquid-to-solid ratio (L/S) 10l·kgTS; however, significant differences were observed for P, Pb, Ba, Mg and Zn. Further differences emerged in terms of concentration in the early eluates (L/S<5l·kg(-1)TS) for Al, As, Ba, Cd, Cu, DOC, Mg, Mn, Ni, P, Pb, Sb, Se, Si, Zn. Observed differences between tests are likely to be due to differences in pH related to crushing and exposure of fresh particle surfaces, as well as in equilibrium conditions. In the case of C&DW, the standardised column tests, which are more practical, are considered to acceptably describe cumulative releases at L/S 10l·kg(-1)TS in percolation scenarios. However, when the focus is on estimation of initial concentrations for (for example) risk assessment, data from standardised column tests may not be fully applicable, and data from lysimeters may be used for validation purposes. Se, Cr and, to a lesser extent, SO4 and Sb were leaching from C&DW in critical amounts compared with existing limit values. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Role of failure-mechanism identification in accelerated testing

    Science.gov (United States)

    Hu, J. M.; Barker, D.; Dasgupta, A.; Arora, A.

    1993-01-01

    Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.

  3. The equilibrium leach testing of ferric/aluminium hydroxide flocs

    International Nuclear Information System (INIS)

    Biddle, P.; Greenfield, B.F.; Greenham, P.S.; Rees, J.H.

    1987-09-01

    Equilibrium leach tests have been carried out on ferric/aluminium hydroxide flocs using cement and resin matrices, and cement and clay backfills in both air and nitrogen atmospheres. The equilibrium concentrations of a number of actinides and fission products were measured in leachates obtained over periods of up to a year. The lowest equilibrium actinide concentrations were found in leachates from systems with a cement backfill. Cement matrix-cement backfill was the most promising combination for limiting concentrations of long-lived radionuclides, resin-clay the least. Comparison of leachate concentrations with limiting drinking water concentrations are made and the high degree of protection afforded by candidate near field components shown. (author)

  4. The equilibrium leach testing of ferric/aluminium hydroxide flocs

    International Nuclear Information System (INIS)

    Biddle, P.; Greenfield, B.F.; Greenham, P.S.; Rees, J.H.

    1987-09-01

    Equilibrium leach tests have been carried out on ferric/aluminium hydroxide flocs using cement and resin matrices, and cement and clay backfills in both air and nitrogen atmospheres. The equilibrium concentrations of a number of actinides and fission products were measured in leachates obtained over periods of up to a year. The lowest equilibrium actinide concentrations were found in leachates from systems with a cement backfill. Cement matrix-cement backfill was the most promising combination for limiting concentrations of long-lived radionuclides, resin-clay the least. Comparisons of leachate concentrations with limiting drinking water concentrations are made and the high degree of protection afforded by candidate near field components shown. (author)

  5. Acceleration test with mixed higher harmonics in HIMAC

    International Nuclear Information System (INIS)

    Kanazawa, M.; Sugiura, A.; Misu, T.

    2004-01-01

    In HIMAC synchrotron, beam tests with a magnetic ally loaded cavity have been performed. This cavity has very low Q-value of about 0.5, and can be added higher harmonics with fundamental acceleration frequency. In our tested system for higher harmonics, wave form of a DDS (Direct Digital Synthesizer) can be rewrite, and arbitrary wave form can be used for beam acceleration. In the beam test, second and third harmonic wave were added on the fundamental acceleration frequency, and increases of the accelerated beam intensity have been achieved. In this paper, results of the beam test and the acceleration system are presented. (author)

  6. Implementation of the Leaching Environmental Assessment ...

    Science.gov (United States)

    LEAF provides a uniform and integrated approach for evaluating leaching from solid materials (e.g., waste, treated wastes such as by solidification/stabilization, secondary materials such as blast furnace slags, energy residuals such as coal fly ash, soil, sediments, mining and mineral processing wastes). Assessment using LEAF applies a stepwise approach that considers the leaching behavior of COPCs in response to chemical and physical factors that control and material properties across a range of plausible field conditions (US EPA, 2010). The framework provides the flexibility to tailor testing to site conditions and select the extent of testing based on assessment objectives and the level of detailed information needed to support decision-making. The main focus will be to discuss the implementation of LEAF in the US and the How to Guide that has recently been completed. To present the How To Guide for the implementation of the leaching environmental assessment framework to an international audience already familiar with comparable leaching tests in use in Europe. Will be meeting with European colleagues on their interest in expanding methods to include organics.

  7. Leaching properties of solidified TRU waste forms

    International Nuclear Information System (INIS)

    Colombo, P.; Neilson, R.M. Jr.

    1979-01-01

    Safety analysis of waste forms requires an estimate of the ability of these forms to retain activity in the disposal environment. This program of leaching tests will determine the leaching properties of TRU contaminated incinerator ash waste forms using hydraulic cement, urea--formaldehyde, bitumen, and vinyl ester--styrene as solidification agents. Three types of leaching tests will be conducted, including both static and flow rate. Five generic groundwaters will be used. Equipment and procedures are described. Experiments have been conducted to determine plate out of 239 Pu, counter efficiency, and stability of counting samples

  8. Current practices in corrosion, surface characterization, and nickel leach testing of cardiovascular metallic implants.

    Science.gov (United States)

    Nagaraja, Srinidhi; Di Prima, Matthew; Saylor, David; Takai, Erica

    2017-08-01

    In an effort to better understand current test practices and improve nonclinical testing of cardiovascular metallic implants, the Food and Drug Administration (FDA) held a public workshop on Cardiovascular Metallic Implants: corrosion, surface characterization, and nickel leaching. The following topics were discussed: (1) methods used for corrosion assessments, surface characterization techniques, and nickel leach testing of metallic cardiovascular implant devices, (2) the limitations of each of these in vitro tests in predicting in vivo performance, (3) the need, utility, and circumstances when each test should be considered, and (4) the potential testing paradigms, including acceptance criteria for each test. In addition to the above topics, best practices for these various tests were discussed, and knowledge gaps were identified. Prior to the workshop, discussants had the option to provide feedback and information on issues relating to each of the topics via a voluntary preworkshop assignment. During the workshop, the pooled responses were presented and a panel of experts discussed the results. This article summarizes the proceedings of this workshop and background information provided by workshop participants. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. J Biomed Mater Res Part B: Appl Biomater, 105B: 1330-1341, 2017. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  9. Ultrasound augmented leaching of nickel sulfate in sulfuric acid and hydrogen peroxide media.

    Science.gov (United States)

    Li, Haoyu; Li, Shiwei; Peng, Jinhui; Srinivasakannan, Chandrasekar; Zhang, Libo; Yin, Shaohua

    2018-01-01

    A new method of preparation high purity nickel sulfate assisted by ultrasonic was studied. The process mechanism was analyzed by Inductively Coupled Plasma (ICP), X-ray diffraction (XRD), Scanning electron microscopy (SEM), and Energy dispersive X-ray spectrometry (EDS).The reaction mechanisms of oxidizing leaching and ultrasonic leaching were explored, respectively. Results showed that ultrasonic treatment peel off the oxide film on the surface of nickel. The leachate under strongly agitated, the yield rate of nickel sulfate was accelerate. And the reaction area was increased by the cavitation effect, the liquid-solid reaction was promoted, and the activation energy was reduced. The leaching rate of nickel reached 46.29% by conventional leaching, which takes about 5h. Under the same conditions, the ultrasonic leaching rate reached 40%, only half of the conventional leaching time. Concentration of leaching agent, reaction temperature, ultrasonic power, leaching time had significant effect on the enhancement of the leaching reaction with ultrasonic radiation. The leaching rate of 60.41% under the optimum experiment conditions as follows: sulfuric acid concentration 30%, hydrogen peroxide 10%, leaching temperature 333K, ultrasonic power 200W and leaching time 4h. The kinetic study of the system was investigated, and the reaction rates of conventional leaching and ultrasonic leaching were controlled by diffusion, and the apparent activation energies were 16.2kJ/mol and 11.83kJ/mol. Copyright © 2017. Published by Elsevier B.V.

  10. EBR-II blanket fuel leaching test using simulated J-13 well water

    International Nuclear Information System (INIS)

    Fonnesbeck, J. E.

    1999-01-01

    This paper discusses the results of a pulsed-flow leaching test using simulated J-13 well water leachant. This test was performed on three blanket fuel segments from the ANL-W EBR-II nuclear reactor which were originally made up of depleted uranium (DU). This experiment was designed to mimic conditions which would exist if, upon disposal of this material in a geological repository, it came in direct contact with groundwater. These segments were contained in pressure vessels and maintained at a constant temperature of 90 C. Weekly aliquots of leachate were taken from the three vessels and replaced with an equal volume of fresh leachant. These weekly aliquots were analyzed for both 90 Sr and 137 Cs. The results of the pulsed-flow leach test showed the formation of uranium oxide (UO 2 ) and uranium hydride (UH 3 ) particulate with rapid release of the 137 Cs and 90 Sr to the leachant. On the fifth week of sampling, one of the vessels became over pressurized and vented gas when opened. The most reasonable explanation for the presence of gas in this vessel is that the unoxidized uranium metal in the blanket segment could have reacted with the surrounding water leachant to form hydrogen. However, an investigation is currently being undertaken to both qualify and quantify H 2 formation during uranium spent nuclear fuel corrosion in water

  11. Accelerated Solar-UV Test Chamber

    Science.gov (United States)

    Gupta, A.; Laue, E. G.

    1984-01-01

    Medium-pressure mercury-vapor lamps provide high ratio of ultraviolet to total power. Chamber for evaluating solar-ultraviolet (UV) radiation damage permits accelerated testing without overheating test specimens.

  12. Preliminary experimental study on the deterioration of cementitious materials by an acceleration method

    International Nuclear Information System (INIS)

    Saito, H.; Nakane, S.; Ikari, S.; Fujiwara, A.

    1992-01-01

    Development of a deterioration model for cementitious materials is important in assessing long-term integrity of nuclear waste repositories. The authors preliminarily examined a new test method for acceleration of aging of mortar specimens by application of electrical potential gradients and observed whether the method could throw light on the deterioration process of cementitious materials under repository conditions. As a result, it was concluded that the application of a potential gradient to a mortar specimen might be useful as an accelerated test method for assessing the deterioration behavior of cementitious materials due to leaching. (orig.)

  13. A Statistical Perspective on Highly Accelerated Testing

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Edward V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    Highly accelerated life testing has been heavily promoted at Sandia (and elsewhere) as a means to rapidly identify product weaknesses caused by flaws in the product's design or manufacturing process. During product development, a small number of units are forced to fail at high stress. The failed units are then examined to determine the root causes of failure. The identification of the root causes of product failures exposed by highly accelerated life testing can instigate changes to the product's design and/or manufacturing process that result in a product with increased reliability. It is widely viewed that this qualitative use of highly accelerated life testing (often associated with the acronym HALT) can be useful. However, highly accelerated life testing has also been proposed as a quantitative means for "demonstrating" the reliability of a product where unreliability is associated with loss of margin via an identified and dominating failure mechanism. It is assumed that the dominant failure mechanism can be accelerated by changing the level of a stress factor that is assumed to be related to the dominant failure mode. In extreme cases, a minimal number of units (often from a pre-production lot) are subjected to a single highly accelerated stress relative to normal use. If no (or, sufficiently few) units fail at this high stress level, some might claim that a certain level of reliability has been demonstrated (relative to normal use conditions). Underlying this claim are assumptions regarding the level of knowledge associated with the relationship between the stress level and the probability of failure. The primary purpose of this document is to discuss (from a statistical perspective) the efficacy of using accelerated life testing protocols (and, in particular, "highly accelerated" protocols) to make quantitative inferences concerning the performance of a product (e.g., reliability) when in fact there is lack-of-knowledge and uncertainty concerning

  14. Kinetic and Mechanism Study of Vanadium Acid Leaching from Black Shale Using Microwave Heating Method

    Science.gov (United States)

    Wang, Jing-peng; Zhang, Yi-min; Huang, Jing; Liu, Tao

    2018-04-01

    The leaching kinetics of the vanadium leaching process were investigated by the comparison of microwave heating and conventional heating methods. Microwave heating with CaF2 had a synergistic effect and improved the vanadium leaching efficiency. In contrast to conventional heating leaching, microwave heating accelerated the vanadium leaching rate by approximately 1-3% and by approximately 15% when CaF2 was also used. The kinetics analysis showed that the calculated activation energy decreased in the microwave heating method in the presence and absence of CaF2. The control procedure of leaching also changed from a chemical reaction control step to a mixed chemical diffusion control step upon the addition of CaF2. Microwave heating was shown to be suitable for leaching systems with diffusion or mixed chemical diffusion control steps when the target mineral does not have a microwave absorbing ability.

  15. Kinetic and Mechanism Study of Vanadium Acid Leaching from Black Shale Using Microwave Heating Method

    Science.gov (United States)

    Wang, Jing-peng; Zhang, Yi-min; Huang, Jing; Liu, Tao

    2018-06-01

    The leaching kinetics of the vanadium leaching process were investigated by the comparison of microwave heating and conventional heating methods. Microwave heating with CaF2 had a synergistic effect and improved the vanadium leaching efficiency. In contrast to conventional heating leaching, microwave heating accelerated the vanadium leaching rate by approximately 1-3% and by approximately 15% when CaF2 was also used. The kinetics analysis showed that the calculated activation energy decreased in the microwave heating method in the presence and absence of CaF2. The control procedure of leaching also changed from a chemical reaction control step to a mixed chemical diffusion control step upon the addition of CaF2. Microwave heating was shown to be suitable for leaching systems with diffusion or mixed chemical diffusion control steps when the target mineral does not have a microwave absorbing ability.

  16. Accelerated Stress-Corrosion Testing

    Science.gov (United States)

    1986-01-01

    Test procedures for accelerated stress-corrosion testing of high-strength aluminum alloys faster and provide more quantitative information than traditional pass/fail tests. Method uses data from tests on specimen sets exposed to corrosive environment at several levels of applied static tensile stress for selected exposure times then subsequently tensile tested to failure. Method potentially applicable to other degrading phenomena (such as fatigue, corrosion fatigue, fretting, wear, and creep) that promote development and growth of cracklike flaws within material.

  17. Renewal of corrosion progress after long-term leaching

    International Nuclear Information System (INIS)

    Muller, I.

    1997-01-01

    Over the past 18 years a large inventory of glasses which have undergone leach testing has been built up at the Vitreous State Laboratory of The Catholic University of America. These glasses include a very wide range of compositions, most from actual mixed wastes and many natural analogs. A variety in the test protocol have been used, including PCT, ANSI, TCLP, IAEA, Flow, Soxhlet, MCC1, MCC3, and DIN. Many of these tests have been conducted for over a decade and are still ongoing. The progress of the tests is monitored by periodic sampling with fluid replacement. Twenty different leachants (including groundwaters, humic acid and pH buffers) have been employed. Occasionally, some of the glass is removed from the leaching vessels to observe the altered layers forming on the glass and to identify reaction products. Slight variations in the composition of the glass, subjected to PCT leaching, exhibit widely differing leaching behaviors. The evolution of leachate composition over time often shows a basically stable leach rate followed by a dramatic increase, with times of onset varying considerably, primarily as a function of glass composition. The same rapid rise in leachate has also been observe for a given glass composition studied at different S/V ratio. The study of such non-linearity in glass leaching is the subject of this review. (author)

  18. Alkaline autoclave leaching of refractory uranium-thorium minerals

    International Nuclear Information System (INIS)

    Milani, S. A.; Sam, S.

    2011-01-01

    This paper deals with the study of an innovative method for processing the Oman placer ores by alkaline leaching in ball mill autoclaves, where grinding and leaching of the refractory minerals take place simultaneously. This was followed by the selective separation of thorium and uranium from lanthanides by autoclave leaching of the hydroxide cake with ammonium carbonate-bicarbonate solutions. The introduced method is based on the fact that thorium and uranium form soluble carbonate complexes with ammonium carbonate, while lanthanides form sparingly soluble double carbonates. It was found that a complete alkaline leaching of Oman placer ores (98.0 P ercent ) was attained at 150 and 175 d egree C within 2.5 and 2h, respectively. Oman placer ores leaching was intensified and accelerated in a ball mill autoclaves as a result of the grinding action of steel balls, removal of the hydroxide layer covering ores grains and the continuous contact of fresh ore grains with alkaline solution. The study of selective carbonate processing of hydroxide cake with ammonium carbonate-bicarbonate solutions on autoclave under pressure revealed that the complete thorium recovery (97.5 P ercent ) with uranium recovery (90.8 P ercent ) and their separation from the lanthanides were attained at 70-80 d egree C during l-2h. The extraction of lanthanides in carbonate solution was low and did not exceed 4.6 P ercent .

  19. Heap-leaching of low-grade uranium ore at SOMAIR: from laboratory tests to production of 700 tonnes U per year

    Energy Technology Data Exchange (ETDEWEB)

    Durupt, N.; Blanvillain, J.J., E-mail: nicolas.durupt@areva.com [AREVA NC, Service d' Etudes de Procedes et d' Analyses (SEPA), Bessines sur Gartempe (France)

    2010-07-01

    In 2006, SOMAIR decided to increase the uranium production by 50% using heap leaching for the treatment of low grade ores. These ores, which come from different ores with various properties, have been studied in four steps: Lab tests: to compare the ores (characterization, acid consumptions, recovery); Column tests on an average sample: to define significant parameters for a feasibility study; Column tests on specific samples: to optimize recovery for each ore and identify problems of percolation due to the clays; and, Pilot tests in large boxes (stalls): to validate process parameters. Uranium production by heap leaching started commercially in July 2009. (author)

  20. Relationship between reaction layer thickness and leach rate for nuclear waste glasses

    International Nuclear Information System (INIS)

    Chick, L.A.; Pederson, L.R.

    1984-02-01

    Three leaching tests, devised to distinguish among several proposed nuclear waste glass leaching mechanisms, were carried out for four different waste glasses. In the first test, the influence of a pre-formed reaction layer on elemental release was evaluated. In the second test, glass specimens were replaced with fresh samples halfway through the leaching experiment, to evaluate the influence of the concentration of glass components in leaching. Finally, regular replacement of the leachant at fixed time intervals essentially removed the variable changing solution concentration, and allowed an assessment of the influence of reaction layer thickness on the leaching rate. Results for all glasses tested indicated that the reaction layer presented little or no barrier to leaching, and that most of the retardation on leaching rates generally observed are attributable to saturation effects. 20 references, 6 figures, 1 table

  1. Pretreatment Engineering Platform (PEP) Integrated Test B Run Report--Caustic and Oxidative Leaching in UFP-VSL-T02A

    Energy Technology Data Exchange (ETDEWEB)

    Geeting, John GH; Bredt, Ofelia P.; Burns, Carolyn A.; Golovich, Elizabeth C.; Guzman-Leong, Consuelo E.; Josephson, Gary B.; Kurath, Dean E.; Sevigny, Gary J.; Aaberg, Rosanne L.

    2009-12-10

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes” of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing.

  2. Quantitative accelerated degradation testing: Practical approaches

    International Nuclear Information System (INIS)

    Mohammadian, S. Hossein; Ait-Kadi, Daoud; Routhier, Francois

    2010-01-01

    The concept of accelerated testing by tracking degradation of samples over test time needs to be developed for reliability estimation. This paper aims at proposing practical approaches to conduct accelerated degradation testing on new and available used samples. For this purpose, product failure is related to a suitable physical property. Then, its failure time is defined as the expected time in which its property reaches the critical level. Degradation model of field samples returned from service due to a degrading failure mode has been estimated based on the least square method, and available gap between manufacturer criterion and user's claim (to report a failure) has also been discussed. For a product under some stresses, a general formula has been proposed by the superposition principle in order to estimate its degradation for independent and dependent failure modes. If used samples are available, and acceleration factor of the related test is unknown, partial aging method has been presented to considerably shorten the test time.

  3. Coupling between chemical degradation and mechanical behaviour of leached concrete

    International Nuclear Information System (INIS)

    Nguyen, V.H.

    2005-10-01

    This work is in the context of the long term behavior of concrete employed in radioactive waste disposal. The objective is to study the coupled chemo-mechanical modelling of concrete. In the first part of this contribution, experimental investigations are described where the effects of the calcium leaching process of concrete on its mechanical properties are highlighted. An accelerated method has been chosen to perform this leaching process by using an ammonium nitrate solution. In the second part, we present a coupled phenomenological chemo-mechanical model that represents the degradation of concrete materials. On one hand, the chemical behavior is described by the simplified calcium leaching approach of cement paste and mortar. Then a homogenization approach using the asymptotic development is presented to take into account the influence of the presence of aggregates in concrete. And on the other hand, the mechanical part of the modelling is given. Here continuum damage mechanics is used to describe the mechanical degradation of concrete. The growth of inelastic strains observed during the mechanical tests is describes by means of a plastic like model. The model is established on the basis of the thermodynamics of irreversible processes framework. The coupled nonlinear problem at hand is addressed within the context of the finite element method. Finally, numerical simulations are compared with the experimental results for validation. (author)

  4. Preparation and leaching of radioactive INEL waste forms

    International Nuclear Information System (INIS)

    Schuman, R.P.; Welch, J.M.; Staples, B.A.

    1982-01-01

    The purpose of this study is to prepare and leach test ceramic and glass waste form specimens produced from actual transuranic waste sludges and high-level waste calcines, respectively. Description of wastes, specimen fabrication, leaching procedure, analysis of leachates and results are discussed. The conclusion is that radioactive waste stored at INEL can be readily incorporated in fused ceramic and glass forms. Initial leach testing results indicate that these forms show great promise for safe long-term containment of radioactive wastes

  5. The Brookhaven Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.C.; Fischer, J.; Fisher, A.S.; Gallardo, J.; Jialin, Xie; Kirk, H.G.; Parsa, Z.; Palmer, R.B.; Rao, T.; Rogers, J.; Sheehan, J.; Tsang, T.Y.F.; Ulc, S.; Van Steenbergen, A.; Woodle, M.; Zhang, R.S.; McDonald, K.T.; Russell, D.P.; Jiang, Z.Y.; Pellegrini, C.; Wang, X.J.

    1990-01-01

    The Accelerator Test Facility (ATF), presently under construction at Brookhaven National laboratory, is described. It consists of a 50-MeV electron beam synchronizable to a high-peak power CO 2 laser. The interaction of electrons with the laser field will be probed, with some emphasis on exploring laser-based acceleration techniques. 5 refs., 2 figs

  6. Intensification Behavior of Mercury Ions on Gold Cyanide Leaching

    Directory of Open Access Journals (Sweden)

    Qiang Zhong

    2018-01-01

    Full Text Available Cyanidation is the main method used to extract gold from gold raw materials; however, a serious problem with this method is the low leaching rate. In order to improve gold leaching, the intensification behavior of mercury ions on gold cyanide leaching, for two types of materials, sulphide gold concentrate and oxide gold ore, was investigated. The results showed that mercury ions, with only a 10−5 M dosage, could significantly intensify leaching and gold recovery. The dissolution behavior of gold plate was also intensified by 10−5 M mercury ions. Microstructure analysis showed that mercury ions intensified the cyanidation corrosion of the gold surface, resulting in a loose structure, where a large number of deep ravines and raised particles were evident across the whole gold surface. The loose structure added contact surface between the gold and cyanide, and accelerated gold dissolution. Moreover, mercury ions obstructed the formation of insoluble products, such as AuCN, Au(OHCN, and Au(OHx, that lead to a passivation membrane on the gold surface, reducing contact between the gold and cyanide. These effects, brought about by mercury ions, change the structure and product of the gold surface during gold cyanidation and promote gold leaching.

  7. Heavy Metal Leaching as Affected by Long-Time Organic Waste Fertilizer Application.

    Science.gov (United States)

    Lekfeldt, Jonas Duus Stevens; Holm, Peter E; Kjærgaard, Charlotte; Magid, Jakob

    2017-07-01

    The recycling of urban waste products as fertilizers in agriculture may introduce contaminants such as heavy metals into soil that may leach and contaminate groundwater. In the present study, we investigated the leaching of heavy metals from intact soil cores collected in the long-term agricultural field trial CRUCIAL. At the time of sampling, the equivalent of >100 yr of urban waste fertilizers following Danish legislation had been applied. The leaching of Cu was significantly increased in the treatments receiving organic waste products compared with the unfertilized control but remained below the permissible level following Danish drinking water guidelines. The leaching of Cu was controlled primarily by the topsoil Cu content and by the leaching of dissolved organic carbon (DOC) but at the same time significantly correlated with leaching of colloids in soils that had not received fertilizer or had received an organic fertilizer with a low concentration of Cu. The leaching of Zn, Cd, and Co was not significantly increased in urban waste-fertilized treatments. The leaching of Mo was elevated in accelerated waste treatments (both agricultural and urban), and the leaching of Mo was linked to the leaching of DOC. Since leaching of Cr and Pb was strongly linked to the level of colloid leaching, leaching of these metals was reduced in the urban waste treatments. Overall, the results presented should not raise concern regarding the agricultural use of urban waste products in agriculture as long as the relevant guidelines are followed. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  8. Study of radionuclide leaching from the residues of K Basin sludge dissolution

    International Nuclear Information System (INIS)

    Bechtold, D.B.

    1998-01-01

    The sludges remaining in the K Basins after removal of the spent N Reactor nuclear fuel will be conditioned for disposal. After conditioning, an acid-insoluble residue will remain that may require further leaching to properly condition it for disposal. This document presents a literature study to identify and recommend one or more chemical leaching treatments for laboratory testing, based on the likely compositions of the residues. The processes identified are a nitric acid cerate leach, a silver-catalyzed persulfate leach, a nitric hydrofluoric acid leach, an oxalic citric acid reactor decontamination leach, a nitric hydrochloric acid leach, a ammonium fluoride nitrate leach, and a HEOPA formate dehydesulfoxylate leach. All processes except the last two are recommended for testing in that order

  9. Accelerated life testing effects on CMOS microcircuit characteristics

    Science.gov (United States)

    1980-01-01

    The 250 C, 200C and 125C accelerated tests are described. The wear-out distributions from the 250 and 200 C tests were used to estimate the activation energy between the two test temperatures. The duration of the 125 C test was not sufficient to bring the test devices into the wear-out region. It was estimated that, for the most complex of the three devices types, the activation energy between 200 C and 125 C should be at least as high as that between 250 C and 200 C. The practicality of the use of high temperature for the accelerated life tests from the point of view of durability of equipment is assessed. Guidlines for the development of accelerated life-test conditions are proposed. The use of the silicon nitride overcoat to improve the high temperature accelerated life-test characteristics of CMOS microcircuits is described.

  10. Accelerated stress testing of terrestrial solar cells

    Science.gov (United States)

    Lathrop, J. W.; Hawkins, D. C.; Prince, J. L.; Walker, H. A.

    1982-01-01

    The development of an accelerated test schedule for terrestrial solar cells is described. This schedule, based on anticipated failure modes deduced from a consideration of IC failure mechanisms, involves bias-temperature testing, humidity testing (including both 85-85 and pressure cooker stress), and thermal-cycle thermal-shock testing. Results are described for 12 different unencapsulated cell types. Both gradual electrical degradation and sudden catastrophic mechanical change were observed. These effects can be used to discriminate between cell types and technologies relative to their reliability attributes. Consideration is given to identifying laboratory failure modes which might lead to severe degradation in the field through second quadrant operation. Test results indicate that the ability of most cell types to withstand accelerated stress testing depends more on the manufacturer's design, processing, and worksmanship than on the particular metallization system. Preliminary tests comparing accelerated test results on encapsulated and unencapsulated cells are described.

  11. Leaching Properties of Naturally Occurring Heavy Metals from Soils

    Science.gov (United States)

    Zhang, M.; Hoshino, M.; Yoshikawa, M.; Hara, J.; Sugita, H.

    2014-12-01

    The major threats to human health from heavy metals are associated with exposure to arsenic, lead, cadmium, chromium, mercury, as well as some other elements. The effects of such heavy metals on human health have been extensively studied and reviewed by international organizations such as WHO. Due to their toxicity, heavy metal contaminations have been regulated by national environmental standards in many countries, and/or laws such as the Soil Contamination Countermeasures Act in Japan. Leaching of naturally occurring heavy metals from the soils, especially those around abandoned metal mines into surrounding water systems, either groundwater or surface water systems, is one of the major pathways of exposure. Therefore, understanding the leaching properties of toxic heavy metals from naturally polluted soils is of fundamentally importance for effectively managing abandoned metal mines, excavated rocks discharged from infrastructure constructions such as tunneling, and/or selecting a pertinent countermeasure against pollution when it is necessary. In this study, soil samples taken from the surroundings of abandoned metal mines in different regions in Japan were collected and analyzed. The samples contained multiple heavy metals such as lead, arsenic and chromium. Standard leaching test and sequential leaching test considering different forms of contaminants, such as trivalent and pentavalent arsenics, and trivalent and hexavalent chromiums, together with standard test for evaluating total concentration, X-ray Fluorescence Analysis (XRF), X-ray diffraction analysis (XRD) and Cation Exchange Capacity (CEC) tests were performed. In addition, sequential leaching tests were performed to evaluate long-term leaching properties of lead from representative samples. This presentation introduces the details of the above experimental study, discusses the relationships among leaching properties and chemical and mineral compositions, indicates the difficulties associated with

  12. The leaching of lead from lead-based paint in landfill environments.

    Science.gov (United States)

    Wadanambi, Lakmini; Dubey, Brajesh; Townsend, Timothy

    2008-08-30

    Lead leaching from lead-based paint (LBP) was examined using standardized laboratory protocols and tests with leachate from actual and simulated landfill environments. Two different LBP samples were tested; leaching solutions included leachates from three municipal solid waste (MSW) landfills and three construction and demolition (C&D) debris landfills. The toxicity characteristic leaching procedure (TCLP) and the synthetic precipitation leaching procedure (SPLP) were also performed. Lead concentrations were many times higher using the TCLP compared to the SPLP and the landfill leachates. No significant difference (alpha=0.05) was observed in leached lead concentrations from the MSW landfill and C&D debris landfill leachates. The impact of other building materials present in LBP debris on lead leaching was examined by testing mixtures of LBP (2%) and different building materials (98%; steel, wood, drywall, concrete). The type of substrate present impacted lead leaching results, with concrete demonstrating the most dramatic impact; the lowest lead concentrations were measured in the presence of concrete under both TCLP and SPLP extractions.

  13. Leaching assessment of road materials containing primary lead and zinc slags.

    Science.gov (United States)

    Barna, R; Moszkowicz, P; Gervais, C

    2004-01-01

    Characterisation of the leaching behaviour of waste-containing materials is a crucial step in the environmental assessment for reuse scenarios. In our research we applied the multi-step European methodology ENV 12-920 to the leaching assessment of road materials containing metallurgical slag. A Zn slag from an imperial smelting furnace (ISF) and a Pb slag from a lead blast furnace (LBF) are investigated. The two slags contain up to 11.2 wt% of lead and 3.5 wt% of zinc and were introduced as a partial substitute for sand in two road materials, namely sand-cement and sand-bitumen. At the laboratory scale, a leaching assessment was performed first through batch equilibrium leaching tests. Second, the release rate of the contaminants was evaluated using saturated leaching tests on monolithic material. Third, laboratory tests were conducted on monolithic samples under intermittent wetting conditions. Pilot-scale tests were conducted for field testing of intermittent wetting conditions. The results show that the release of Pb and Zn from the materials in a saturated scenario was controlled by the pH of the leachates. For the intermittent wetting conditions, an additional factor, blocking of the pores by precipitation during the drying phase is proposed. Pilot-scale leaching behaviour only partially matched with the laboratory-scale test results: new mass transfer mechanisms and adapted laboratory leaching tests are discussed.

  14. Zinc Leaching from Tire Crumb Rubber

    Science.gov (United States)

    Rhodes, E. P.; Ren, J.; Mays, D. C.

    2010-12-01

    Recent estimates indicate that more than 2 billion scrap tires are currently stockpiled in the United States and approximately 280 million more tires are added annually. Various engineering applications utilize recycled tires in the form of shredded tire crumb rubber. However, the use of tire crumb rubber may have negative environmental impacts, especially when the rubber comes into contact with water. A review of the literature indicates that leaching of zinc from tire crumb rubber is the most significant water quality concern associated with using this material. Zinc is generally used in tire manufacturing, representing approximately 1.3% of the final product by mass. This study will report results from the U.S. Environmental Protection Agency’s (EPA’s) Synthetic Precipitation Leaching Procedure, batch leaching tests, and column leaching tests performed to quantify the process by which zinc leaches from tire crumb rubber into water. Results are interpreted with a first-order kinetic attachment/detachment model, implemented with the U.S. Agricultural Research Service software HYDRUS-1D, in order to determine the circumstances when zinc leaching from tire crumb rubber would be expected to comply with the applicable discharge limits. One potential application for recycled tires is replacing sand with tire crumb rubber in granular media filters used for stormwater pollution control. For this to be a viable application, the total zinc in the stormwater discharge must be below the EPA’s benchmark value of 0.117 mg/L.

  15. Leaching of gallium from gaiter granite, eastern desert, Egypt

    International Nuclear Information System (INIS)

    Zahran, M.A.; Mahmoud, KH.F.; Mahdy, M.A.; Abd El-Hamid, A.M.

    2006-01-01

    Preliminary leaching tests of gallium from some Egyptian granite rocks such as those of Gabal Gattar area was investigated by using 8 M HCl acid and sodium perchlorate as oxidant. To achieve the optimum leaching conditions, the factors affecting the leaching efficiency as the acid type and concentration, oxidant type and amount, leaching temperature, agitation time, solid / liquid ratio and the effect of grain size were studied. The complete chemical analysis of the collected samples was firstly carried out to determine the chemical features of the Gattarian granite. More than 97% of gallium content was leached when applying these optimum leaching conditions

  16. Life estimation I and C cable insulation materials based on accelerated life testing accelerated life testing

    International Nuclear Information System (INIS)

    Santhosh, T.V.; Ramteke, P.K.; Shrestha, N.B.; Ahirwar, A.K.; Gopika, V.

    2016-01-01

    Accelerated Iife tests are becoming increasingly popular in today's industry due to the need for obtaining life data quickly and reliably. Life testing of products under higher stress levels without introducing additional failure modes can provide significant savings of both time and money. Correct analysis of data gathered via such accelerated life testing will yield parameters and other information for the product's life under use stress conditions. To be of practical use in assessing the operational behaviour of cables in NPPs, laboratory ageing aims to mimic the type of degradation observed under operational conditions. Conditions of testing therefore need to be carefully chosen to ensure that the degradation mechanism occurring in the accelerated tests are similar to those which occur in service. This paper presents the results of an investigation in which the elongation-at-break (EAB) measurements were carried on a typical control cable to predict the mean life at service conditions. A low voltage polyvinyl chloride (PVC) insulated and PVC sheathed control cable, used in NPP instrumentation and control (I and C) applications, was subjected thermal ageing at three elevated temperatures

  17. The Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.

    1992-01-01

    The Brookhaven National Laboratory Accelerator Test Facility comprises a 50 MeV traveling wave electron linear accelerator utilizing a high gradient, photo-excited, raidofrequency electron gun as an injector and an experimental area for study of new acceleration methods or advanced radiation sources using free electron lasers. Early operation of the linear accelerator system including calculated and measured beam parameters are presented together with the experimental program for accelerator physics and free electron laser studies

  18. Suitability of leaching test methods for fly ash and slag: A review

    Directory of Open Access Journals (Sweden)

    Manoj Kumar Tiwari

    2015-10-01

    Full Text Available Fly ash and slag leachate pollution can be of great environmental concern due to generation of these wastes in huge quantities from their respective industrial units, mainly coal-based thermal power plants and iron and steel plants. For simulation of natural leaching in laboratory, various leaching methods are available, but selection of a method that can exactly simulate the real-life scenario for accurate estimation of various pollutants is challenging; particularly, the heavy metals present and impact due to reuse or disposal of these wastes. For choosing the most suitable leaching method according to specific situation, one must primarily consider the chemical and physical properties of wastes, the composition of the source, age of waste disposal, and the climatic conditions of the disposal area. Since these factors may not be specified, a variety of leaching methods with relevant equipment have been proposed by researchers; that are based on their required information to particular conditions in absence of a prescribed protocol and non standardization of equipment. The present review is an attempt to investigate the suitable leaching method for coal fly ash and slag.

  19. Column leaching from biomass combustion ashes

    DEFF Research Database (Denmark)

    Maresca, Alberto; Astrup, Thomas Fruergaard

    2015-01-01

    The utilization of biomass combustion ashes for forest soil liming and fertilizing has been addressed in literature. Though, a deep understanding of the ash chemical composition and leaching behavior is necessary to predict potential benefits and environmental risks related to this practice....... In this study, a fly ash sample from an operating Danish power plant based on wood biomass was collected, chemically characterized and investigated for its leaching release of nutrients and heavy metals. A column leaching test was employed. The strongly alkaline pH of all the collected eluates suggested...

  20. Hanford Tank 241-S-112 Residual Waste Composition and Leach Test Data

    Energy Technology Data Exchange (ETDEWEB)

    Cantrell, Kirk J.; Krupka, Kenneth M.; Geiszler, Keith N.; Lindberg, Michael J.; Arey, Bruce W.; Schaef, Herbert T.

    2008-08-29

    This report presents the results of laboratory characterization and testing of two samples (designated 20406 and 20407) of residual waste collected from tank S-112 after final waste retrieval. These studies were completed to characterize the residual waste and assess the leachability of contami¬nants from the solids. This is the first report from this PNNL project to describe the composition and leach test data for residual waste from a salt cake tank. All previous PNNL reports (Cantrell et al. 2008; Deutsch et al. 2006, 2007a, 2007b, 2007c) describing contaminant release models, and characterization and testing results for residual waste in single-shell tanks were based on samples from sludge tanks.

  1. Leaching from municipal solid waste incineration residues

    Energy Technology Data Exchange (ETDEWEB)

    Hyks, J.

    2008-02-15

    Leaching of pollutants from Municipal Solid Waste Incineration (MSWI) residues has been investigated combining a range of laboratory leaching experiments with geochemical modeling. Special attention was paid to assessing the applicability of laboratory data for subsequent modeling with respect to presumed full-scale conditions; both sample pretreatment and actual influence of leaching conditions on the results of laboratory experiments were considered. It was shown that sample pretreatment may have large impact on leaching test data. In particular, a significant fraction of Pb was shown mobile during the washing of residues with water. In addition, drying of residues (i.e. slow oxidation) prior to leaching experiments increased the leaching of Cr significantly. Significant differences regarding the leaching behavior of individual elements with respect to (non)equilibrium conditions in column percolation experiments were observed in the study. As a result, three groups of elements were identified based on the predominant leaching control and the influence of (non)equilibrium on the results of the laboratory column experiments: I. Predominantly availability-controlled elements (e.g. Na, K, Cl) II. Solubility-controlled elements (e.g. Ca, S, Si, Al, Ba, and Zn) III. Complexation-controlled elements (e.g. Cu and Ni) With respect to the above groups it was suggested that results of laboratory column experiments can, with consideration, be used to estimate full-scale leaching of elements from Group I and II. However, in order to avoid large underestimations in the assessment of leaching from Group III, it is imperative to describe the time-dependent transport of dissolved organic carbon (DOC) in the tested system or to minimize the physical non-equilibrium during laboratory experiments (e.g. bigger column, slower flow velocity). Forward geochemical modeling was applied to simulate long-term release of elements from a MSWI air-pollution-control residue. Leaching of a

  2. Implementation Guidance for the Next Generation Leaching Tests

    Science.gov (United States)

    Poster provides an overview of the purpose and utility of this research, highlights of the research to support the Leaching Environmental Assessment Framework (LEAF), application and translation (including data management and analysis software), intended end users, and lessons le...

  3. Leaching of nuclear power reactor wastes forms

    International Nuclear Information System (INIS)

    Endo, L.S.; Villalobos, J.P.; Miyamoto, H.

    1986-01-01

    The leaching tests for power reactor wastes carried out at IPEN/CNEN-SP are described. These waste forms consist mainly of spent resins and boric acid concentrates solidified in ordinary Portland cement. All tests were conducted according to the ISO and IAEA recommendations. 3 years leaching results are reported, determining cesium and strontium diffusivity coefficients for boric acid waste form and ion-exchange resins. (Author) [pt

  4. Statistical comparison of leaching behavior of incineration bottom ash using seawater and deionized water: Significant findings based on several leaching methods.

    Science.gov (United States)

    Yin, Ke; Dou, Xiaomin; Ren, Fei; Chan, Wei-Ping; Chang, Victor Wei-Chung

    2018-02-15

    Bottom ashes generated from municipal solid waste incineration have gained increasing popularity as alternative construction materials, however, they contains elevated heavy metals posing a challenge for its free usage. Different leaching methods are developed to quantify leaching potential of incineration bottom ashes meanwhile guide its environmentally friendly application. Yet, there are diverse IBA applications while the in situ environment is always complicated, challenging its legislation. In this study, leaching tests were conveyed using batch and column leaching methods with seawater as opposed to deionized water, to unveil the metal leaching potential of IBA subjected to salty environment, which is commonly encountered when using IBA in land reclamation yet not well understood. Statistical analysis for different leaching methods suggested disparate performance between seawater and deionized water primarily ascribed to ionic strength. Impacts of leachant are metal-specific dependent on leaching methods and have a function of intrinsic characteristics of incineration bottom ashes. Leaching performances were further compared on additional perspectives, e.g. leaching approach and liquid to solid ratio, indicating sophisticated leaching potentials dominated by combined geochemistry. It is necessary to develop application-oriented leaching methods with corresponding leaching criteria to preclude discriminations between different applications, e.g., terrestrial applications vs. land reclamation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Leaching of Conductive Species: Implications to Measurements of Electrical Resistivity.

    Science.gov (United States)

    Spragg, R; Jones, S; Bu, Y; Lu, Y; Bentz, D; Snyder, K; Weiss, J

    2017-05-01

    Electrical tests have been used to characterize the microstructure of porous materials, the measured electrical response being determined by the contribution of the microstructure (porosity and tortuosity) and the electrical properties of the solution (conductivity of the pore solution) inside the pores of the material. This study has shown how differences in concentration between the pore solution (i.e., the solution in the pores) and the storage solution surrounding the test specimen leads to significant transport (leaching) of the conductive ionic species between the pore solution and the storage solution. Leaching influences the resistivity of the pore solution, thereby influencing electrical measurements on the bulk material from either a surface or uniaxial bulk resistance test. This paper has three main conclusions: 1.) Leaching of conductive species does occur with concentration gradients and that a diffusion based approach can be used to estimate the time scale associated with this change. 2.) Leaching of ions in the pore solution can influence resistivity measurements, and the ratio of surface to uniaxial resistivity can be used as a method to assess the presence of leaching and 3.) An estimation of the magnitude of leaching for standardized tests of cementitious materials.

  6. Glass composition effects on the results of MCC-1, MCC-3 and pulsed-flow leach tests

    International Nuclear Information System (INIS)

    Barkatt, A.; Adiga, R.; Adel-Hadadi, M.A.; Barkatt, A.; Feng, X.; Sousanpour, W.

    1989-01-01

    Glass composition effects on the results of MCC-1, MCC-3 and pulsed-flow leach tests are summarized. Major components of the glasses studied are included. The leachant in all cases was de-ionized water and the temperature was 90 degree C. Test duration of the MCC-1 and MCC-3 was 28 days. The total time in the pulsed-flow test was 112 days. In the MCC-1 test, the results indicate that the forward rate characteristic of the kinetics of leaching in unsaturated environments is relatively independent (within a factor of 2) of such variations. The MCC-3 results reflect the extent of glass dissolution under conditions where the extent of interaction is large enough to cause the solution in contact with the glass to approach saturation with respect to silica and other scarcely soluble components. The pulsed-flow results show that at longer periods of time the dependence of leachate composition on glass composition decreases again and that leachate concentrations approach stabilization at levels which are much lower than the MCC-3 limits

  7. Leaching of CCA-treated wood: implications for waste disposal

    International Nuclear Information System (INIS)

    Townsend, Timothy; Tolaymat, Thabet; Solo-Gabriele, Helena; Dubey, Brajesh; Stook, Kristin; Wadanambi, Lakmini

    2004-01-01

    Leaching of arsenic, chromium, and copper from chromated copper arsenate (CCA)-treated wood poses possible environmental risk when disposed. Samples of un-weathered CCA-treated wood were tested using a variety of the US regulatory leaching procedures, including the toxicity characteristic leaching procedure (TCLP), synthetic precipitation leaching procedure (SPLP), extraction procedure toxicity method (EPTOX), waste extraction test (WET), multiple extraction procedure (MEP), and modifications of these procedures which utilized actual MSW landfill leachates, a construction and demolition (C and D) debris leachate, and a concrete enhanced leachate. Additional experiments were conducted to assess factors affecting leaching, such as particle size, pH, and leaching contact time. Results from the regulatory leaching tests provided similar results with the exception of the WET, which extracted greater quantities of metals. Experiments conducted using actual MSW leachate, C and D debris leachate, and concrete enhanced leachate provided results that were within the same order of magnitude as results obtained from TCLP, SPLP, and EPTOX. Eleven of 13 samples of CCA-treated dimensional lumber exceeded the US EPA's toxicity characteristic (TC) threshold for arsenic (5 mg/L). If un-weathered arsenic-treated wood were not otherwise excluded from the definition of hazardous waste, it frequently would require management as such. When extracted with simulated rainwater (SPLP), 9 of the 13 samples leached arsenic at concentrations above 5 mg/L. Metal leachability tended to increase with decreasing particle size and at pH extremes. All three metals leached above the drinking water standards thus possibly posing a potential risk to groundwater. Arsenic is a major concern from a disposal point of view with respect to ground water quality

  8. Uranium leaching by fungal metabolite

    International Nuclear Information System (INIS)

    Wang Yongdong; Li Guangyue; Ding Dexin; Hu Nan

    2012-01-01

    To explore new means of bioleaching, one strain of high-yielding fungi-Aspergillus niger which could produce organic acids was separated and purified from soil samples of uranium mine. The influence of cultural temperature, initial pH value, inoculum sizes on its growth characteristics were carried out. And the tests of uranium leaching of metabolin of Aspergillus niger were operated. On these tests, the effects of metabolin of Aspergillus niger with different pH value produced in the diverse culture temperature on uranium leaching were investigated. The results show that this strain of Aspergillus niger can grow best under the following conditions: the temperature is 37℃, the initial pH value is 7.0, the inoculum sizes is 2% (the OD value of the spores solution is 0.06). The uranium extraction effects relative to the final pH value of the cultures. and the maximum leaching rates is 83.05% when the pH value is 2.3. (authors)

  9. Influencing factors and kinetics analysis on the leaching of iron from boron carbide waste-scrap with ultrasound-assisted method.

    Science.gov (United States)

    Li, Xin; Xing, Pengfei; Du, Xinghong; Gao, Shuaibo; Chen, Chen

    2017-09-01

    In this paper, the ultrasound-assisted leaching of iron from boron carbide waste-scrap was investigated and the optimization of different influencing factors had also been performed. The factors investigated were acid concentration, liquid-solid ratio, leaching temperature, ultrasonic power and frequency. The leaching of iron with conventional method at various temperatures was also performed. The results show the maximum iron leaching ratios are 87.4%, 94.5% for 80min-leaching with conventional method and 50min-leaching with ultrasound assistance, respectively. The leaching of waste-scrap with conventional method fits the chemical reaction-controlled model. The leaching with ultrasound assistance fits chemical reaction-controlled model, diffusion-controlled model for the first stage and second stage, respectively. The assistance of ultrasound can greatly improve the iron leaching ratio, accelerate the leaching rate, shorten leaching time and lower the residual iron, comparing with conventional method. The advantages of ultrasound-assisted leaching were also confirmed by the SEM-EDS analysis and elemental analysis of the raw material and leached solid samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Laboratory Test of Newton's Second Law for Small Accelerations

    International Nuclear Information System (INIS)

    Gundlach, J. H.; Schlamminger, S.; Spitzer, C. D.; Choi, K.-Y.; Woodahl, B. A.; Coy, J. J.; Fischbach, E.

    2007-01-01

    We have tested the proportionality of force and acceleration in Newton's second law, F=ma, in the limit of small forces and accelerations. Our tests reach well below the acceleration scales relevant to understanding several current astrophysical puzzles such as the flatness of galactic rotation curves, the Pioneer anomaly, and the Hubble acceleration. We find good agreement with Newton's second law at accelerations as small as 5x10 -14 m/s 2

  11. The role equilibrium leach testing in understanding the behaviour of nuclear wastes under disposal conditions

    International Nuclear Information System (INIS)

    Biddle, P.; Rees, J.H.

    1988-01-01

    Results from the equilibrium leach testing of a range of intermediate level nuclear wastes have been modelled successfully using sorption and solubility data obtained in experiments with individual radionuclides. The wastes involved included fuel cladding (after removal of irradiated fuel for reprocessing), combustible plutonium-contaminated materials and ferric/aluminium hydroxide flocs. The test has an important role in validating nearfield models, and helps to build confidence in disposal assessments. (orig.)

  12. Evaluating the applicability of regulatory leaching tests for assessing the hazards of Pb-contaminated soils.

    Science.gov (United States)

    Halim, Cheryl E; Scott, Jason A; Amal, Rose; Short, Stephen A; Beydoun, Donia; Low, Gary; Cattle, Julie

    2005-04-11

    Soil contamination is a major environmental problem due to the ecological threat it poses. In this work, electron probe microanalysis (EPMA), X-ray diffraction (XRD), and leaching studies were employed to explain the different leaching behaviors of non-stabilized and stabilized soils. The applicability of the leaching fluids used in the toxicity characteristic leaching procedure (TCLP) and Australian Standards, AS 4439.1-1997 for assessing the hazards of contaminated soils was investigated as was the leaching of lead from soil stabilized by cement and buffered phosphate techniques. The results showed Pb speciation in the soil highly influenced metal leaching. The synthetic leaching fluids were unable to provide a reliable estimation of Pb concentration in the municipal landfill leachate (ML) due to the absence of organic ligands capable of forming stable complexes with the lead. Water provided the closest representation of lead leaching from the non-stabilized and phosphate stabilized soils while sodium tetraborate buffer was found to be suitable for cement-stabilized soil in a non-putrescible landfill leachate system. A comparison of stabilization methods revealed that the buffered phosphate technique was more suitable for stabilizing the lead in the soil relative to cement stabilization.

  13. Evaluating the applicability of regulatory leaching tests for assessing the hazards of Pb-contaminated soils

    International Nuclear Information System (INIS)

    Halim, Cheryl E.; Scott, Jason A.; Amal, Rose; Short, Stephen A.; Beydoun, Donia; Low, Gary; Cattle, Julie

    2005-01-01

    Soil contamination is a major environmental problem due to the ecological threat it poses. In this work, electron probe microanalysis (EPMA), X-ray diffraction (XRD), and leaching studies were employed to explain the different leaching behaviors of non-stabilized and stabilized soils. The applicability of the leaching fluids used in the toxicity characteristic leaching procedure (TCLP) and Australian Standards, AS 4439.1-1997 for assessing the hazards of contaminated soils was investigated as was the leaching of lead from soil stabilized by cement and buffered phosphate techniques. The results showed Pb speciation in the soil highly influenced metal leaching. The synthetic leaching fluids were unable to provide a reliable estimation of Pb concentration in the municipal landfill leachate (ML) due to the absence of organic ligands capable of forming stable complexes with the lead. Water provided the closest representation of lead leaching from the non-stabilized and phosphate stabilized soils while sodium tetraborate buffer was found to be suitable for cement-stabilized soil in a non-putrescible landfill leachate system. A comparison of stabilization methods revealed that the buffered phosphate technique was more suitable for stabilizing the lead in the soil relative to cement stabilization

  14. OPTIMUM DESIGN OF EXPERIMENTS FOR ACCELERATED RELIABILITY TESTING

    Directory of Open Access Journals (Sweden)

    Sebastian Marian ZAHARIA

    2014-05-01

    Full Text Available In this paper is presented a case study that demonstrates how design to experiments (DOE information can be used to design better accelerated reliability tests. In the case study described in this paper, will be done a comparison and optimization between main accelerated reliability test plans (3 Level Best Standard Plan, 3 Level Best Compromise Plan, 3 Level Best Equal Expected Number Failing Plan, 3 Level 4:2:1 Allocation Plan. Before starting an accelerated reliability test, it is advisable to have a plan that helps in accurately estimating reliability at operating conditions while minimizing test time and costs. A test plan should be used to decide on the appropriate stress levels that should be used (for each stress type and the amount of the test units that need to be allocated to the different stress levels (for each combination of the different stress types' levels. For the case study it used ALTA 7 software what provides a complete analysis for data from accelerated reliability tests

  15. Effects of extraction methods and factors on leaching of metals from recycled concrete aggregates.

    Science.gov (United States)

    Bestgen, Janile O; Cetin, Bora; Tanyu, Burak F

    2016-07-01

    Leaching of metals (calcium (Ca), chromium (Cr), copper, (Cu), iron (Fe), and zinc (Zn)) of recycled concrete aggregates (RCAs) were investigated with four different leachate extraction methods (batch water leach tests (WLTs), toxicity leaching procedure test (TCLP), synthetic precipitation leaching procedure test (SPLP), and pH-dependent leach tests). WLTs were also used to perform a parametric study to evaluate factors including (i) effects of reaction time, (ii) atmosphere, (iii) liquid-to-solid (L/S) ratio, and (iv) particle size of RCA. The results from WLTs showed that reaction time and exposure to atmosphere had impact on leaching behavior of metals. An increase in L/S ratio decreased the effluent pH and all metal concentrations. Particle size of the RCA had impact on some metals but not all. Comparison of the leached concentrations of metals from select RCA samples with WLT method to leached concentrations from TCLP and SPLP methods revealed significant differences. For the same RCA samples, the highest metal concentrations were obtained with TCLP method, followed by WLT and SPLP methods. However, in all tests, the concentrations of all four (Cr, Cu, Fe, and Zn) metals were below the regulatory limits determined by EPA MCLs in all tests with few exceptions. pH-dependent batch water leach tests revealed that leaching pattern for Ca is more cationic whereas for other metals showed more amphoteric. The results obtained from the pH-dependent tests were evaluated with geochemical modeling (MINTEQA2) to estimate the governing leaching mechanisms for different metals. The results indicated that the releases of the elements were solubility-controlled except Cr.

  16. Vehicle accelerated corrosion test procedures for automotive in Malaysia

    Directory of Open Access Journals (Sweden)

    Anuar Liza

    2017-01-01

    Full Text Available An accelerated corrosion test, known as proving ground accelerated test, is commonly performed by automotive manufacturers to evaluate the corrosion performance of a vehicle. The test combines corrosion and durability inputs to detect potential failures that may occur during in-service conditions. Currently, the test is conducted at an external test center overseas. Such test is aimed to simulate the effects of one year accelerated corrosion in severe corrosive environment of the north-east and south east of America. However, the test results obtained do not correlate with the actual corrosion conditions observed in the Malaysian market, which is likely attributed to the different test environment of the tropical climate of vehicles in service. Therefore, a vehicle accelerated corrosion test procedure that suits the Malaysian market is proposed and benchmarked with other global car manufacturers that have their own dedicated corrosion test procedure. In the present work, a test track is used as the corrosion test ground and consists of various types of roads for structural durability exposures. Corrosion related facilities like salt trough, mud trough and gravel road are constructed as addition to the existing facilities. The establishment of accelerated corrosion test facilities has contributed to the development of initial accelerated corrosion test procedure for the national car manufacturer. The corrosion exposure is monitored by fitting test coupons at the underbody of test vehicle using mass loss technique so that the desired corrosion rate capable of simulating the real time corrosion effects for its target market.

  17. Earthquake acceleration amplification based on single microtremor test

    Science.gov (United States)

    Jaya Syahbana, Arifan; Kurniawan, Rahmat; Soebowo, Eko

    2018-02-01

    Understanding soil dynamics is needed to understand soil behaviour, including the parameters of earthquake acceleration amplification. Many researchers now conduct single microtremor tests to obtain amplification of velocity and natural periods of soil at test sites. However, these amplification parameters are rarely used, so a method is needed to convert the velocity amplification to acceleration amplification. This paper will discuss the proposed process of changing the value of amplification. The proposed method is to integrate the time histories of the synthetic earthquake acceleration of the soil surface under the deaggregation at that location so the time histories of the velocity earthquake will be obtained. Next is to conduct a “fitting curve” between amplification by a single microtremor test with amplification of the synthetic earthquake velocity time histories. After obtaining the fitting curve time histories of velocity, differentiation will be conducted to obtain fitting curve acceleration time histories. The final step after obtaining the fitting curve is to compare the acceleration of the “fitting curve” against the histories time of the acceleration of synthetic earthquake at bedrocks to obtain single microtremor acceleration amplification factor.

  18. On bacteria oxidizing enlargement scale test for uranium in-situ leaching at. 381 mine

    International Nuclear Information System (INIS)

    Hu Kaiguang; Wang Qingliang; Liu Yingjiu; Shi Wenge; Hu Shihe; Hu Yincai; Fang Qiu

    1999-01-01

    The results of enlarged scale test of bacteria as oxidizer for uranium in-situ leaching at No 381 mine showed that redox potential of the oxidized absorbed tailing water by bacteria is more than 510 mV, without any effects on after treatments by using bacteria as oxidizer and reduce oxidizer costs 70% compared with H 2 O 2 as oxidizer

  19. LEACH-A: An Adaptive Method for Improving LEACH Protocol

    Directory of Open Access Journals (Sweden)

    Jianli ZHAO

    2014-01-01

    Full Text Available Energy has become one of the most important constraints on wireless sensor networks. Hence, many researchers in this field focus on how to design a routing protocol to prolong the lifetime of the network. The classical hierarchical protocols such as LEACH and LEACH-C have better performance in saving the energy consumption. However, the choosing strategy only based on the largest residue energy or shortest distance will still consume more energy. In this paper an adaptive routing protocol named “LEACH-A” which has an energy threshold E0 is proposed. If there are cluster nodes whose residual energy are greater than E0, the node of largest residual energy is selected to communicated with the base station; When all the cluster nodes energy are less than E0, the node nearest to the base station is select to communication with the base station. Simulations show that our improved protocol LEACH-A performs better than the LEACH and the LEACH-C.

  20. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  1. Recent progress of the advanced test accelerator

    International Nuclear Information System (INIS)

    Prono, D.S.

    1985-01-01

    The Advanced Test Accelerator (ATA) of Lawrence Livermore National Laboratory is a linear induction accelerator whose electron beam parameters are 10 kA, 50 MeV, and 70 ns. This accelerator structure basically is a 2.5 MeV injector followed by 190 identical induction accelerator cores each of which incrementally adds 250 kV to the electron beam as it threads the center of the core. Recent work on beam stability, beam emittance and beam brightness is reported

  2. base cation leaching from the canopy of a rubber (hevea brasiliensis

    African Journals Online (AJOL)

    Osondu

    2012-08-11

    Aug 11, 2012 ... accelerated by acid rain, by forest regrowth following harvest removals, and by declining inputs of base cations from atmospheric deposition. Cation leaching from tree canopy could affect physiological processes, damage flowering and dormancy patterns, and make plants more vulnerable to diseases and ...

  3. Test Stand for Linear Induction Accelerator Optimization

    International Nuclear Information System (INIS)

    Ong, M; DeHope, B; Griffin, K; Goerz, D; Kihara, R; Vogtlin, G; Zentler, J M; Scarpetti, R

    2003-01-01

    Lawrence Livermore National Laboratory has designed and constructed a test stand to improve the voltage regulation in our Flash X-Ray (FXR) accelerator cell. The goal is to create a more mono-energetic electron beam that will create an x-ray source with a smaller spot size. Studying the interaction of the beam and pulse-power system with the accelerator cell will improve the design of high-current accelerators at Livermore and elsewhere. On the test stand, a standard FXR cell is driven by a flexible pulse-power system and the beam current is simulated with a switched center conductor. The test stand is fully instrumented with high-speed digitizers to document the effect of impedance mismatches when the cell is operated under various full-voltage conditions. A time-domain reflectometry technique was also developed to characterize the beam and cell interactions by measuring the impedance of the accelerator and pulse-power component. Computer models are being developed in parallel with the testing program to validate the measurements and evaluate different design changes. Both 3D transient electromagnetic and circuit models are being used

  4. Certain aspects of leaching kinetics of solidified ''radioactive wastes'' - Laboratory studies

    International Nuclear Information System (INIS)

    Amarantos, S.G.; Petropoulos, J.H.

    1981-01-01

    A laboratory study of the kinetics of leaching of Cs + and Sr ++ incorporated as sulphates in cement (Portland type) or base asphalt with distilled water as leachant is reported. The comparison of different leaching methods (including stagnant or stirred leachant with periodic renewal and a new method of ''continuous leachant renewal'') and the study of the effect of temperature were among the particular objectives of this work. The results for the cemented salts indicate that the new method of ''continuous leachant renewal'' is more efficient than the others. Is has been also found that the other leaching methods, including the widely used stagnant, periodically renewed leachant, can be seriously affected in certain circumstances by factors which have hitherto been left uncontrolled. An observed sharp diminution in the elution rate of Sr ++ from cement samples appears to be attributable to the action of atmospheric CO 2 . It has been observed that temperature affects the acceleration in the earlier and later stages of cement-Cs 2 SO 4 leaching. (T.A.)

  5. Advanced Test Accelerator (ATA) pulse power technology development

    International Nuclear Information System (INIS)

    Reginato, L.L.; Branum, D.; Cook, E.

    1981-01-01

    The Advanced Test Accelerator (ATA) is a pulsed linear induction accelerator with the following design parameters: 50 MeV, 10 kA, 70 ns, and 1 kHz in a ten-pulse burst. Acceleration is accomplished by means of 190 ferrite-loaded cells, each capable of maintaining a 250 kV voltage pulse for 70 ns across a 1-inch gap. The unique characteristic of this machine is its 1 kHz burst mode capability at very high currents. This paper dscribes the pulse power development program which used the Experimental Test Accelerator (ETA) technology as a starting base. Considerable changes have been made both electrically and mechanically in the pulse power components with special consideration being given to the design to achieve higher reliability. A prototype module which incorporates all the pulse power components has been built and tested for millions of shots. Prototype components and test results are described

  6. Test accelerator for linear collider

    International Nuclear Information System (INIS)

    Takeda, S.; Akai, K.; Akemoto, M.; Araki, S.; Hayano, H.; Hugo, T.; Ishihara, N.; Kawamoto, T.; Kimura, Y.; Kobayashi, H.; Kubo, T.; Kurokawa, S.; Matsumoto, H.; Mizuno, H.; Odagiri, J.; Otake, Y.; Sakai, H.; Shidara, T.; Shintake, T.; Suetake, M.; Takashima, T.; Takata, K.; Takeuchi, Y.; Urakawa, J.; Yamamoto, N.; Yokoya, K.; Yoshida, M.; Yoshioka, M.; Yamaoka, Y.

    1989-01-01

    KEK has proposed to build Test Accelerator Facility (TAF) capable of producing a 2.5 GeV electron beam for the purpose of stimulating R ampersand D for linear collider in TeV region. The TAF consists of a 1.5 GeV S-band linear accelerator, 1.5 GeV damping ring and 1.0 GeV X-band linear accelerator. The TAF project will be carried forward in three phases. Through Phase-I and Phase-II, the S-band and X-band linacs will be constructed, and in Phase-III, the damping ring will be completed. The construction of TAF Phase-I has started, and the 0.2 GeV S-band injector linac has been almost completed. The Phase-I linac is composed of a 240 keV electron gun, subharmonic bunchers, prebunchers and traveling buncher followed by high-gradient accelerating structures. The SLAC 5045 klystrons are driven at 450 kV in order to obtain the rf-power of 100 MW in a 1 μs pulse duration. The rf-power from a pair of klystrons are combined into an accelerating structure. The accelerating gradient up to 100 MeV/m will be obtained in a 0.6 m long structure. 5 refs., 3 figs., 2 tabs

  7. Inspection of piping wall loss with flow accelerated corrosion accelerated simulation test

    International Nuclear Information System (INIS)

    Ryu, Kyung Ha; Kim, Ji Hak; Hwang, Il Soon; Lee, Na Young; Kim, Ji Hyun

    2009-01-01

    Flow Accelerated Corrosion (FAC) has become a hot issue for aging of passive components. Ultrasonic Technique (UT) has been adopted to inspect the secondary piping of Nuclear Power Plants (NPPs). UT, however, uses point detection method, which results in numerous detecting points and thus takes time. We developed an Equipotential Switching Direct Current Potential Drop (ES-DCPD) method to monitor the thickness of piping that covers wide range of piping at once time. Since the ES-DCPD method covers area, not a point, it needs less monitoring time. This can be a good approach to broad carbon steel piping system such as secondary piping of NPPs. In this paper, FAC accelerated simulation test results is described. We realized accelerated FAC phenomenon by 2 times test: 23.7% thinning in 216.7 hours and 51% thinning in 795 hours. These were monitored by ES-DCPD and traditional UT. Some parameters of water chemistry are monitored and controlled to accelerate FAC process. As sensitive factors on FAC, temperature and pH was changed during the test. The wall loss monitored results reflected these changes of water chemistry successfully. Developed electrodes are also applied to simulation loop to monitor water chemistry. (author)

  8. Effect of carbonation on the leaching of organic carbon and of copper from MSWI bottom ash.

    Science.gov (United States)

    Arickx, S; De Borger, V; Van Gerven, T; Vandecasteele, C

    2010-07-01

    In Flanders, the northern part of Belgium, about 31% of the produced amount of MSWI bottom ash is recycled as secondary raw material. In view of recycling a higher percentage of bottom ash, a particular bottom ash fraction (Ø 0.1-2mm) was studied. As the leaching of this bottom ash fraction exceeds some of the Flemish limit values for heavy metals (with Cu being the most critical), treatment is required. Natural weathering and accelerated carbonation resulted in a significant decrease of the Cu leaching. Natural weathering during 3 months caused a decrease of Cu leaching to <50% of its original value, whereas accelerated carbonation resulted in an even larger decrease (to ca. 13% of its initial value) after 2 weeks, with the main decrease taking place within the first 48 h. Total organic carbon decreased to ca. 70% and 55% of the initial concentration in the solid phase, and to 40% and 25% in the leachate after natural weathering and after accelerated carbonation, respectively. In the solid material the decrease of the Hy fraction was the largest, the FA concentration remained essentially constant. The decrease of FA in the leachate can be attributed partly to an enhanced adsorption of FA to Fe/Al (hydr)oxides, due to the combined effect of a pH decrease and the neoformation of Al (hydr)oxides (both due to carbonation). A detailed study of adsorption of FA to Fe/Al (hydr)oxides showed that significant adsorption of FA occurs, that it increases with decreasing pH and started above pH 12 for Fe (hydr)oxides and around 10 for Al (hydr)oxides. Depending whether FA or Hy are considered the controlling factor in enhanced Cu leaching, the decreasing FA or Hy in the leachate explains the decrease in the Cu leaching during carbonation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  9. Leaching tests of cemented organic radioactive waste

    International Nuclear Information System (INIS)

    Calabria, Jaqueline A. Almeida; Haucz, Maria Judite A.; Tello, Cledola Cassia O.

    2011-01-01

    The use of radioisotopes in research, medical and industrial activities generates organic liquid radioactive wastes. At Centro de Desenvolvimento da Tecnologia Nuclear (CDTN) are produced organic liquid wastes from different sources, one of these are the solvent extraction activities, whose the waste volume is the largest one. Therefore a research was carried out to treat them. Several techniques to treat organic liquid radioactive wastes have been evaluated, among them incineration, oxidation processes, alkaline hydrolysis, distillation, absorption and cementation. Laboratory experiments were accomplished to establish the most adequate process in order to obtain qualified products for storage and disposal. Absorption followed by cementation was the procedure used in this study, i.e. absorbent substances were added to the organic liquid wastes before mixing with the cement. Initially were defined the absorbers, and evaluated the formulation in relation to the compressive strength of its products. Bentonite from different suppliers (B and G) and vermiculite in two granulometries (M - medium and F - small) were tested. In order to assess the product quality the specimens were submitted to the leaching test according the Standard ISO 6961 and its results were evaluated. Then they were compared with the values established by Standard CNEN NN 6.09 A cceptance criteria for waste products to be disposed , to verify if they meet the requirements for safely storage and disposal. Through this study the best formulations to treat the organic wastes were established. (author)

  10. Cathodic Delamination Accelerated Life Test Method

    National Research Council Canada - National Science Library

    Ramotowski, Thomas S

    2007-01-01

    A method for conducting an accelerated life test of a polymer coated metallic sample includes placing the sample below the water surface in a test tank containing water and an oxygen containing gas...

  11. Significance of acceleration period in a dynamic strength testing study.

    Science.gov (United States)

    Chen, W L; Su, F C; Chou, Y L

    1994-06-01

    The acceleration period that occurs during isokinetic tests may provide valuable information regarding neuromuscular readiness to produce maximal contraction. The purpose of this study was to collect the normative data of acceleration time during isokinetic knee testing, to calculate the acceleration work (Wacc), and to determine the errors (ERexp, ERwork, ERpower) due to ignoring Wacc during explosiveness, total work, and average power measurements. Seven male and 13 female subjects attended the test by using the Cybex 325 system and electronic stroboscope machine for 10 testing speeds (30-300 degrees/sec). A three-way ANOVA was used to assess gender, direction, and speed factors on acceleration time, Wacc, and errors. The results indicated that acceleration time was significantly affected by speed and direction; Wacc and ERexp by speed, direction, and gender; and ERwork and ERpower by speed and gender. The errors appeared to increase when testing the female subjects, during the knee flexion test, or when speed increased. To increase validity in clinical testing, it is important to consider the acceleration phase effect, especially in higher velocity isokinetic testing or for weaker muscle groups.

  12. The role of equilibrium leach testing in understanding the behaviour of nuclear wastes under disposal conditions

    International Nuclear Information System (INIS)

    Biddle, P.; Rees, J.H.

    1988-01-01

    Results from the equilibrium leach testing of a range of intermediate level nuclear wastes have been modelled using sorption and solubility data obtained in experiments with individual radionuclides. The wastes involved were AGR hulls, Magnox cladding wastes, combustible plutonium-contaminated materials and ferric/aluminium hydroxide flocs. The test has an important role in validating near-field models, and helps to build confidence in disposal assessments. (author)

  13. Leaching Studies on ACR-1000{sup R} Fuel Under Reactor Operating Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sunder, S. [Atomic Energy of Canada Limited, Fuel and Fuel Channel Safety Branch, Chalk River, Ontario, K0J 1J0 (Canada)

    2009-06-15

    ACR-1000{sup R} is the latest nuclear power reactor being developed by AECL. The ACR-1000 fuel uses a modified CANFLEX{sup R} fuel bundle that contains low-enriched uranium and pellets of burnable neutron absorbers (BNA) in a central element. Dysprosium and gadolinium are used as the burnable neutron absorbers and are present as oxides in a 'fully-stabilized' zirconia matrix. The BNA material in the centre element is designed to limit the coolant void reactivity of the reactor core during postulated loss-of-coolant accidents. As part of the ACR-1000 fuel development, the stability of the BNA material under conditions associated with defects of the Zircaloy sheathing of the BNA central element has been investigated. The results of these tests can be used to demonstrate the phase stability and leaching behaviour of the ACR-1000 fuel under reactor operating conditions. The samples were disks, about 3-4 mm thick, obtained from BNA pellets and Candu fuel (natural uranium UO{sub 2}) pellets (the UO{sub 2} measurements provide a reference point). Leaching tests were carried out in light water at 325 deg. C, above the maximum coolant temperature in an ACR-1000 fuel channel during normal operating conditions (319 deg. C). This temperature also bounds the maximum operating temperature for the current Candu reactors (311 deg. C). The initial pH of the solution (measured at room temperature) used in the leaching tests was 10.3. The leach rates were determined by monitoring the amount of metals leached into solutions. Leaching tests were also carried out with BNA pellet samples in the presence of Zr-2.5%Nb pressure tube coupons to determine the effects, if any, of the presence of pressure tube material on leach rates. Other leaching tests with BNA pellet samples and UO{sub 2} pellets were conducted at 80 deg. C to study the effects of temperature on the leach rates. The temperature of 80 deg. C was selected as representative of typical shutdown temperatures

  14. Advanced Superconducting Test Accelerator (ASTA)

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Superconducting Test Accelerator (ASTA) facility will be based on upgrades to the existing NML pulsed SRF facility. ASTA is envisioned to contain 3 to 6...

  15. Successful trials on pressure leaching of uranium

    International Nuclear Information System (INIS)

    Pendreigh, R.

    1978-01-01

    High pressure leaching can increase uranium extraction from some low grade ores by ten per cent, and Anglo American Corporation's eighteen months of pilot plant tests point the way to commercial application. Interest in pressure leaching of uranium has been renewed with the recent increase in uranium and gold prices and costs of reagents

  16. Characterization of Tank 16H Annulus Samples Part II: Leaching Results

    International Nuclear Information System (INIS)

    Hay, M.; Reboul, S.

    2012-01-01

    The closure of Tank 16H will require removal of material from the annulus of the tank. Samples from Tank 16H annulus were characterized and tested to provide information to evaluate various alternatives for removing the annulus waste. The analysis found all four annulus samples to be composed mainly of Si, Na, and Al and lesser amounts of other elements. The XRD data indicate quartz (SiO 2 ) and sodium aluminum nitrate silicate hydrate (Na 8 (Al 6 Si 6 O 24 )(NO 3 ) 2 .4H 2 O) as the predominant crystalline mineral phases in the samples. The XRD data also indicate the presence of crystalline sodium nitrate (NaNO 3 ), sodium nitrite (NaNO 2 ), gibbsite (Al(OH) 3 ), hydrated sodium bicarbonate (Na 3 H(CO 3 ) 2 .2H 2 O), and muscovite (KAl 2 (AlSi 3 O 10 )(OH) 2 ). Based on the weight of solids remaining at the end of the test, the water leaching test results indicate 20-35% of the solids dissolved after three contacts with an approximately 3:1 volume of water at 45 C. The chemical analysis of the leachates and the XRD results of the remaining solids indicate sodium salts of nitrate, nitrite, sulfate, and possibly carbonate/bicarbonate make up the majority of the dissolved material. The majority of these salts were dissolved in the first water contact and simply diluted with each subsequent water contact. The water leaching removed large amounts of the uranium in two of the samples and approximately 1/3 of the 99 Tc from all four samples. Most of the other radionuclides analyzed showed low solubility in the water leaching test. The oxalic acid leaching test result indicate approximately 34-47% of the solids in the four annulus samples will dissolve after three contacts with an approximately 3:1 volume of acid to solids at 45 C. The same sodium salts found in the water leaching test comprise the majority of dissolved material in the oxalic acid leaching test. However, the oxalic acid was somewhat more effective in dissolving radionuclides than the water leach. In

  17. Cement based grouts - longevity laboratory studies: leaching behaviour

    International Nuclear Information System (INIS)

    Onofrei, M.; Gray, M.; Roe, L.

    1991-12-01

    This report describes a series of laboratory tests carried out to determine the possible leaching behaviour of cement-based grouts in repository environments. A reference high-performance cement-based grout, comprised of Canadian Type 50 (U.S. Type V) Sulphate Resisting Portland Cement, silica fume, potable water and superplasticizer, and a commercially available cement grout were subjected to leaching in distilled water and three simulated groundwaters of different ionic strength. Hardened, monolithic specimens of the grout were leached in static, pulsed-flow and continuous flow conditions at temperatures from 10 degrees C to 150 degrees C for periods of up to 56 days. The changes in concentration of ions in the leachants with time were determined and the changes in the morphology of the surfaces of the grout specimens were examined using electron microscopy. After a review of possible mechanisms of degradation of cement-based materials, the data from these experiments are presented. The data show that the grouts will leach when in contact with water through dissolution of more soluble phases. Comparison of the leaching performance of the two grouts indicates that, while there are some minor differences, they behaved quite similarly. The rate of the leaching processes were found to tend to decrease with time and to be accompanied by precipitation and/or growth of an assemblage of secondary alteration phases (i.e., CaCO 3 , Mg(OH) 2 ). The mechanisms of leaching depended on the environmental conditions of temperature, groundwater composition and water flow rate. Matrix dissolution occurred. However, in many of the tests leaching was shown to be limited by the precipitated/reaction layers which acted as protective surface coatings. (37 refs.) (au)

  18. HEPA filter leaching concept validation trials at the Idaho Chemical Processing Plant

    International Nuclear Information System (INIS)

    Chakravartty, A.C.

    1995-04-01

    The enclosed report documents six New Waste Calcining Facility (NWCF) HEPA filter leaching trials conducted at the Idaho Chemical Processing Plant using a filter leaching system to validate the filter leaching treatment concept. The test results show that a modified filter leaching system will be able to successfully remove both hazardous and radiological constituents to RCRA disposal levels. Based on the success of the filter leach trials, the existing leaching system will be modified to provide a safe, simple, effective, and operationally flexible filter leaching system

  19. Leaching studies on SYNROC at 950C and 2000C

    International Nuclear Information System (INIS)

    Oversby, V.M.; Ringwood, A.E.

    1982-01-01

    Crushed samples of SYNROC containing 9%, 16% and 20% of simulated high-level nuclear waste were tested for leaching behavior in distilled water at 95 0 C and 200 0 . Leach solutions were analyzed for Cs, Ca, Ba, Sr, Ti, Zr, Nd and U. Results showed that leach rates based on these elements did not change significantly as the waste loading was increased from 9 to 20%. At both temperatures, leach rates showed a decrease as leaching progressed until a plateau level was reached. Plateau leach rates, which were between 10 and 100 times lower than initial leach rates, reflect the expected long term leaching behaviour of the samples. Plateau values of leach rates for SYNROC depend on the element being leached. Highest values are found for Cs and Ba (1 to 2 x 10 -7 g/cm 2 d at 95 0 C) and lowest values for U (5 x 10 -10 g/cm 2 d at 95 0 C). Increasing leaching temperature to 200 0 C produces higher leach rates for all elements except Nd. Comparison of SYNROC leach rate data with that for PNL 76-68 glass shows that at 200 0 C the leach rate for U from SYNROC is 3000 times less than that from glass. (Auth.)

  20. Stability and leaching of cobalt smelter fly ash

    DEFF Research Database (Denmark)

    Vítková, Martina; Hyks, Jiri; Ettler, Vojtěch

    2013-01-01

    The leaching behaviour of fly ash from a Co smelter situated in the Zambian Copperbelt was studied as a function of pH (5–12) using the pH-static leaching test (CEN/TS 14997). Various experimental time intervals (48h and 168h) were evaluated. The leaching results were combined with the ORCHESTRA...... modelling framework and a detailed mineralogical investigation was performed on the original FA and leached solid residues. The largest amounts of Co, Cu, Pb and Zn were leached at pH 5, generally with the lowest concentrations between pH 9 and 11 and slightly increased concentrations at pH 12. For most...... detected using SEM/EDS and/or TEM/EDS. The leaching of metals was mainly attributed to the dissolution of metallic particles. Partial dissolution of silicate and glass fractions was assumed to significantly influence the release of Ca, Mg, Fe, K, Al and Si as well as Cu, Co and Zn. The formation of illite...

  1. Proposal for an Accelerator R&D User Facility at Fermilab's Advanced Superconducting Test Accelerator (ASTA)

    Energy Technology Data Exchange (ETDEWEB)

    Church, M. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Edwards, H. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Harms, E. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Henderson, S. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Holmes, S. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Lumpkin, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Kephart, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Levedev, V. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Leibfritz, J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Nagaitsev, S. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Piot, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Northern Illinois Univ., DeKalb, IL (United States); Prokop, C. [Northern Illinois Univ., DeKalb, IL (United States); Shiltsev, V. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Sun, Y. E. [Argonne National Lab. (ANL), Argonne, IL (United States); Valishev, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2013-10-01

    Fermilab is the nation’s particle physics laboratory, supported by the DOE Office of High Energy Physics (OHEP). Fermilab is a world leader in accelerators, with a demonstrated track-record— spanning four decades—of excellence in accelerator science and technology. We describe the significant opportunity to complete, in a highly leveraged manner, a unique accelerator research facility that supports the broad strategic goals in accelerator science and technology within the OHEP. While the US accelerator-based HEP program is oriented toward the Intensity Frontier, which requires modern superconducting linear accelerators and advanced highintensity storage rings, there are no accelerator test facilities that support the accelerator science of the Intensity Frontier. Further, nearly all proposed future accelerators for Discovery Science will rely on superconducting radiofrequency (SRF) acceleration, yet there are no dedicated test facilities to study SRF capabilities for beam acceleration and manipulation in prototypic conditions. Finally, there are a wide range of experiments and research programs beyond particle physics that require the unique beam parameters that will only be available at Fermilab’s Advanced Superconducting Test Accelerator (ASTA). To address these needs we submit this proposal for an Accelerator R&D User Facility at ASTA. The ASTA program is based on the capability provided by an SRF linac (which provides electron beams from 50 MeV to nearly 1 GeV) and a small storage ring (with the ability to store either electrons or protons) to enable a broad range of beam-based experiments to study fundamental limitations to beam intensity and to develop transformative approaches to particle-beam generation, acceleration and manipulation which cannot be done elsewhere. It will also establish a unique resource for R&D towards Energy Frontier facilities and a test-bed for SRF accelerators and high brightness beam applications in support of the OHEP

  2. Materials Characterization Center workshop on leaching of radioactive waste forms. Summary report

    International Nuclear Information System (INIS)

    Ross, W.A.; Strachan, D.M.; Turcotte, R.P.; Westsik, J.H. Jr.

    1980-04-01

    At the first Materials Characterization Center (MCC) workshop, on the leaching of radioactive waste forms, there was general agreement that, after certain revisions, the proposed leach test plan set forth by the MCC can be expected to meet most of the nuclear waste community's waste form durability data requirements. The revisions give a clearer definition of the purposes of each test and the end uses of the data. As a result of the workshop, the format of the test program has been recast to clarify the purposes, limitations, and interrelationships of the individual tests. There was also a recognition that the leach test program must be based on an understanding of the mechanistic principles of leaching, and that further study is needed to ensure that the approved data from the MCC leach tests will be compatible with mechanistic research needs. It was agreed that another meeting of the participants in Working Groups 3 and 4, and perhaps some other experts, should be held as soon as possible to focus just on the definition of leach test requirements for mechanistic research. The MCC plans to hold this meeting in April 1980. Many of the tests that will lead to increased understanding of mechanisms will of necessity be long-term tests, sometimes lasting for several years. But the MCC also faces pressing needs to produce approved data that can be used for the comparison of waste forms in the relative near-term, i.e., in the next 1 to 3 yr. Therefore, it was decided to initiate a round-robin test of the MCC short-term static leach procedure as soon as practicable. The MCC has tentative plans for organization of the round robin in May 1980

  3. Teste de lixiviação de potássio para avaliação do vigor de sementes de soja [Glycine max (L.Merril] Potassium leaching test for the evaluation of soybean seed vigour

    Directory of Open Access Journals (Sweden)

    D.C.F.S. Dias

    1995-12-01

    Full Text Available O presente trabalho teve como objetivo principal investigar a possibilidade de se obter indicações rápidas sobre a qualidade fisiológica de sementes de soja através do teste de lixiviação de potássio, cuja eficiência foi avaliada comparativamente as informações fornecidas por outros métodos considerados adequados para a determinação do vigor. Para tanto, utilizou-se quatro lotes de sementes de soja dos cultivares IAC-8 e IAC-15 que foram submetidos aos testes de germinação, primeira contagem de germinação, envelhecimento artificial, condutividade elétrica e determinação do grau de umidade. Além destes foram conduzidos estudos de lixiviação de potássio utilizando-se amostras de sementes não danificadas e de sementes fisicamente puras. A quantidade de potássio lixiviado foi avaliada em fotômetro de chama após 60, 90, 120 e 150 minutos de embebição a 30ºC. As avaliações feitas aos 60, 90 e 120 minutos mostraram-se adequadas para a identificação de lotes com diferentes níveis de vigor, constituindo-se em um método simples e rápido para a avaliação da qualidade fisiológica das sementes.This work was performed to investigate the possibilities of providing rapid indications on the physiological quality of seeds through the potassium leaching test. Four lots of soybean (Glycine max (L. Merrill seeds, cultivars IAC-8 and IAC-15 were submitted to germination, first count, accelerated aging, electrical conductivity and seed moisture tests. In addition, studies on potassium leaching were conducted with samples of selected non damaged seeds and with pure seeds. The amount of leached potassium was evaluated in a flame photometer after a 60, 90, 120 and 150 minute imbibition at 30°C. The evaluations after 60, 90 and 120 minutes were suitable for the identification of lots with different levels of vigour, thus proving to be a simple and rapid method for seed vigour evaluation.

  4. Characterization and leach investigations of sodium silicate matrices used for immobilization of radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    Sharaf El-Deen, A N; El-Dessouky, M M; Helmy, M A [Petroleum Research Institue, Academy of Scientific Research, Nasr City, Cairo (Egypt); Abed Raouf, M W; El-Dessouky, M I [Hot Lab. Centre, Atomic Energy Authority, Cairo (Egypt)

    1995-10-01

    In this study, simulated liquid waste and radioactive tracers of Cs-137 and Co-60 were used to represent the high-level liquid waste (HLLW). immobilization of the liquid waste was performed by its interaction with commercial sodium silicate hydrosol to the gel point, at room temperature. The candidate waste forms forms were fabricated from the obtained hydrogel through several steps including: drying the hydrogel to a solid gel form, crushing the solid to be in a powder from, pressing the powder to the green disk form using a cold pressing technique and finally the heat treatment of the green disks to the sintered form. Characterization for the obtained waste forms was carried out using: thermal analysis (TGA and DTA), X-ray powder diffraction (XRD) techniques and porosity investigation. The leach tests for the prepared forms were conducted according to the international atomic energy agency (IAEA) standard test (static and accelerated). The static test was carried out for simulated and radioactive waste in distilled, bidistilled and ground water for 28 days. The accelerated (Soxhlet) test was conducted for simulated waste in deionized water for 72 hours. 4 figs., 7 tabs.

  5. Leaching of concrete : the leaching process : extrapolation of deterioration : effect on the structural stability

    OpenAIRE

    Fagerlund, Göran

    2000-01-01

    The leaching process when water attacks concrete, and the effect of leaching on the strength and durability of a concrete structure, is analysed theoretically. Technique for prediction of the future leaching and structural stability is outlined. The analysis is to a certain extent supported by data from literature. The leaching process is divided in five different types: 1: Pure surface leaching 2: Surface leaching involving erosion 3: Homogeneous leaching over the entire structure 4...

  6. Hydrochloric acid leach of Agnew Lake uranium concentrate

    International Nuclear Information System (INIS)

    Haque, K.E.; Ipekoglue, B.

    1981-10-01

    Hydrochloric acid leaching was conducted on the radioactive mineral concentrate separated from the Agenw Lake uranium ore. Leach tests conducted at the optimum conditions (75 0 C; 36 hours; 66.0 Kg HCl/tonne; solid:liquid -1:1) resulted in the extraction of 87% uranium and 84% radium. The radionuclide level of the residue was U-0.016%, Th-0.24% and Ra-65 pCi/g solids. However to obtain a residue almost free of radium (i.e., Ra level at the detection limit: 4-6 pCi/g solids), the first stage leach residue was further treated with hydrochloric acid. The radium level in the best second stage leach residue was also above the target level. Therefore, multistage (3 or 4) hydrochloric acid and/or neutral chloride leaching is recommended to obtain tailings almost free of radionuclide

  7. ALUMINUM AND CHROMIUM LEACHING WORKSHOP WHITEPAPER

    International Nuclear Information System (INIS)

    McCabe, D; Jeff Pike, J; Bill Wilmarth, B

    2007-01-01

    formulations. Disposal of the resulting aluminum and chromium-rich streams are different at the two sites, with vitrification into Low Activity Waste (LAW) glass at Hanford, and solidification in Saltstone at SRS. Prior to disposal, the leachate solutions must be treated to remove radionuclides, resulting in increased operating costs and extended facility processing schedules. Interim storage of leachate can also add costs and delay tank closure. Recent projections at Hanford indicate that up to 40,000 metric tons of sodium would be needed to dissolve the aluminum and maintain it in solution, which nearly doubles the amount of sodium in the entire current waste tank inventory. This underscores the dramatic impact that the aluminum leaching can have on the entire system. A comprehensive view of leaching and the downstream impacts must therefore be considered prior to implementation. Many laboratory scale tests for aluminum and chromium dissolution have been run on Hanford wastes, with samples from 46 tanks tested. Three samples from SRS tanks have been tested, out of seven tanks containing high aluminum sludge. One full-scale aluminum dissolution was successfully performed on waste at SRS in 1982, but generated a very large quantity of liquid waste (∼3,000,000 gallons). No large-scale tests have been done on Hanford wastes. Although the data to date give a generally positive indication that aluminum dissolution will work, many issues remain, predominantly because of variable waste compositions and changes in process conditions, downstream processing, or storage limitations. Better approaches are needed to deal with the waste volumes and limitations on disposal methods. To develop a better approach requires a more extensive understanding of the kinetics of dissolution, as well as the factors that effect rates, effectiveness, and secondary species. Models of the dissolution rate that have been developed are useful, but suffer from limitations on applicable compositional ranges

  8. High-voltage terminal test of a test stand for a 1-MV electrostatic accelerator

    Science.gov (United States)

    Park, Sae-Hoon; Kim, Yu-Seok

    2015-10-01

    The Korea Multipurpose Accelerator Complex has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source and accelerating tube will be installed in a high-pressure vessel. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz radio-frequency power supply, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. The results of the 300-kV high-voltage terminal tests are presented in this paper.

  9. Accelerated Testing Of Photothermal Degradation Of Polymers

    Science.gov (United States)

    Kim, Soon Sam; Liang, Ranty Hing; Tsay, Fun-Dow

    1989-01-01

    Electron-spin-resonance (ESR) spectroscopy and Arrhenius plots used to determine maximum safe temperature for accelerated testing of photothermal degradation of polymers. Aging accelerated by increasing illumination, temperature, or both. Results of aging tests at temperatures higher than those encountered in normal use valid as long as mechanism of degradation same throughout range of temperatures. Transition between different mechanisms at some temperature identified via transition between activation energies, manifesting itself as change in slope of Arrhenius plot at that temperature.

  10. Aquifer restoration techniques for in-situ leach uranium mines

    International Nuclear Information System (INIS)

    Deutsch, W.J.; Bell, N.E.; Mercer, B.W.; Serne, R.J.; Shade, J.W.; Tweeton, D.R.

    1984-02-01

    In-situ leach uranium mines and pilot-scale test facilities are currently operating in the states of Wyoming, Texas, New Mexico and Colorado. This report summarizes the technical considerations involved in restoring a leached ore zone and its aquifer to the required level. Background information is provided on the geology and geochemistry of mineralized roll-front deposits and on the leaching techniques used to extract the uranium. 13 references, 13 figures, 4 tables

  11. Accelerated testing of space batteries

    Science.gov (United States)

    Mccallum, J.; Thomas, R. E.; Waite, J. H.

    1973-01-01

    An accelerated life test program for space batteries is presented that fully satisfies empirical, statistical, and physical criteria for validity. The program includes thermal and other nonmechanical stress analyses as well as mechanical stress, strain, and rate of strain measurements.

  12. Developing MESA : an accelerated reliability test

    NARCIS (Netherlands)

    Baskoro, G.; Rouvroye, J.L.; Bacher, W.; Brombacher, A.C.

    2003-01-01

    This paper describes the on-going research on an accelerated reliability test strategy called MESA (Multiple Environment Stress Analysis) intended to find in a fast and efficient manner (potential) reliability problems during the design phase of high volume consumer products. This test has shown

  13. Leaching of PFC from soils contaminated with PFC of different origin

    Science.gov (United States)

    Kalbe, Ute; Piechotta, Christian; Rothe, Robert

    2017-04-01

    Leaching tests are fundamental tools for the assessment of groundwater impact by contaminated soils concerning the soil-groundwater pathway. Such procedures are supposed to serve as the basis for a reliable leachate prognosis. They can be applied to determine the short and long term leaching behaviour as well as the source term of contaminated soils. For this purpose two types of leaching procedures have been validated in Germany for the examination of the leaching behaviour of frequently occurring organic substances (DIN 19528 - column test and DIN 19529 - batch test). A liquid-to-solid ratio (L/S) of 2 L/kg and 10 L/kg) is the basis for the risk assessment which is implemented in different German regulations. The equivalence of test results for both tests for the same material under investigation has been investigated for a variety of pollutants in order to assess their reliability in compliance testing. However, for emerging pollutants there is hardly data available on this issue. Leaching tests on soils contaminated with emerging pollutants such as PFC (Perfluorinated Surfactants) are currently coming more into consideration due to the increasing detection of contaminated sites. Therefore, two soils were investigated in this study from different contamination source (paper sludge containing compost and fire distinguishing foam) using both leaching tests and both liquid-to-solid ratios. The leachability of the various perfluorinated compounds in relation to their content in solid matter was considered. Furthermore the eluate pre-treatment prior analysis (in particular liquid/solid separation step needed for batch tests) has been taken into account. The comparability of the results from batch and column is dependent on the solubility of the various compounds, on the L/S and on the turbidity in the eluates.

  14. Development of a 20 MeV Dielectric-Loaded Test Accelerator

    International Nuclear Information System (INIS)

    Gold, Steven H.; Fliflet, Arne W.; Lombardi, Marcie; Kinkead, Allen K.; Gai, Wei; Power, John G.; Konecny, Richard; Long, Jidong; Jing, Chunguang; Tantawi, Sami G.; Nantista, Christopher D.; Bruce, Ralph W.; Lewis, David III

    2006-01-01

    This paper presents a progress report on a joint project by the Naval Research Laboratory (NRL) and Argonne National Laboratory (ANL), in collaboration with the Stanford Linear Accelerator Center (SLAC), to develop a dielectric-loaded test accelerator in the magnicon facility at NRL. The accelerator will be powered by an experimental 11.424-GHz magnicon amplifier that presently produces 25 MW of output power in a ∼250-ns pulse at up to 10 Hz. The accelerator will include a 5-MeV electron injector originally developed at the Tsinghua University in Beijing, China, and can incorporate DLA structures up to 0.5 m in length. The DLA structures are being developed by ANL, and shorter test structures fabricated from a variety of dielectric materials have undergone testing at NRL at gradients up to ∼8 MV/m. SLAC has developed components to distribute the power from the two magnicon output arms to the injector and to the DLA accelerating structure with separate control of the power ratio and relative phase. RWBruce Associates, Inc., working with NRL, has investigated means to join short ceramic sections into a continuous accelerator tube by a brazing process using an intense 83-GHz beam. The installation and testing of the first dielectric-loaded test accelerator, including injector, DLA test structure, and spectrometer, should take place within the next year

  15. Leaching characteristics of copper flotation waste before and after vitrification.

    Science.gov (United States)

    Coruh, Semra; Ergun, Osman Nuri

    2006-12-01

    Copper flotation waste from copper production using a pyrometallurgical process contains toxic metals such as Cu, Zn, Co and Pb. Because of the presence of trace amounts of these highly toxic metals, copper flotation waste contributes to environmental pollution. In this study, the leaching characteristics of copper flotation waste from the Black Sea Copper Works in Samsun, Turkey have been investigated before and after vitrification. Samples obtained from the factory were subjected to toxicity tests such as the extraction procedure toxicity test (EP Tox), the toxicity characteristic leaching procedure (TCLP) and the "method A" extraction procedure of the American Society of Testing and Materials. The leaching tests showed that the content of some elements in the waste before vitrification exceed the regulatory limits and cannot be disposed of in the present form. Therefore, a stabilization or inertization treatment is necessary prior to disposal. Vitrification was found to stabilize heavy metals in the copper flotation waste successfully and leaching of these metals was largely reduced. Therefore, vitrification can be an acceptable method for disposal of copper flotation waste.

  16. Speciation analysis and leaching behaviors of selected trace elements in spent SCR catalyst.

    Science.gov (United States)

    Dai, Zejun; Wang, Lele; Tang, Hao; Sun, Zhijun; Liu, Wei; Sun, Yi; Su, Sheng; Hu, Song; Wang, Yi; Xu, Kai; Liu, Liang; Ling, Peng; Xiang, Jun

    2018-09-01

    This study investigated heavy metal chemical speciation and leaching behavior from a board-type spent selective catalytic reduction (SCR) catalyst containing high concentrations of vanadium, chromium, nickel, copper, zinc, and lead. A three-step sequential extraction method, standard toxicity characteristic leaching procedure (TCLP), and leaching characteristic tests have been performed. It was found that the mobility of six heavy metals in the spent SCR catalyst was significantly different. The mobility of the six heavy metals exhibited the following order: Ni > Zn > V > Cr > As > Cu. Meanwhile, TCLP test results revealed relatively high Zn and Cr leaching rate of 83.20% and 10.35%, respectively. It was found that leaching rate was positively correlated with available contents (sum of acid soluble, reducible and oxidizable fractions). Leaching characteristics tests indicated that pH substantially affected the leaching of these heavy metals. In particular, the leaching of Cr, Ni, Cu, and Zn was positively influenced by strong acid, while V and As were easily released in the presence of strong acid and strong alkali (pH 11). In terms of kinetics, the leaching of Cr, Ni, Cu, Zn, and As within the spent catalyst was dominated by erosion and dissolution processes, which were rapid reaction processes. V was released in large amounts within 1 h, but its leaching amount sharply decreased with time due to readsorption. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing

    Science.gov (United States)

    Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerone C.; Kolody, Mark R.

    2011-01-01

    Evaluation of metal-based structures has long relied on atmospheric exposure test sites to determine corrosion resistance in marine environments. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions of the corrosive environment. Their success for correlation to atmospheric exposure is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated laboratory testing, which often focuses on the electrochemical reactions that occur during corrosion conditions, has yet to be universally accepted as a useful tool in predicting the long term service life of a metal despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard and their use is imperative, a method that correlates timescales from atmospheric exposure to accelerated testing would be very valuable. This work uses surface chemistry to interpret the chemical changes occurring on low carbon steel during atmospheric and accelerated corrosion conditions with the objective of finding a correlation between its accelerated and long-term corrosion performance. The current results of correlating data from marine atmospheric exposure conditions at the Kennedy Space Center beachside corrosion test site, alternating seawater spray, and immersion in typical electrochemical laboratory conditions, will be presented. Key words: atmospheric exposure, accelerated corrosion testing, alternating seawater spray, marine, correlation, seawater, carbon steel, long-term corrosion performance prediction, X-ray photoelectron spectroscopy.

  18. Accelerated Testing with Multiple Failure Modes under Several Temperature Conditions

    Directory of Open Access Journals (Sweden)

    Zongyue Yu

    2014-01-01

    Full Text Available A complicated device may have multiple failure modes, and some of the failure modes are sensitive to low temperatures. To assess the reliability of a product with multiple failure modes, this paper presents an accelerated testing in which both of the high temperatures and the low temperatures are applied. Firstly, an acceleration model based on the Arrhenius model but accounting for the influence of both the high temperatures and low temperatures is proposed. Accordingly, an accelerated testing plan including both the high temperatures and low temperatures is designed, and a statistical analysis method is developed. The reliability function of the product with multiple failure modes under variable working conditions is given by the proposed statistical analysis method. Finally, a numerical example is studied to illustrate the proposed accelerated testing. The results show that the proposed accelerated testing is rather efficient.

  19. Leaching Tc-99 from SRP glass in simulated tuff and salt groundwaters

    International Nuclear Information System (INIS)

    Bibler, N.E.; Jurgensen, A.R.

    1987-01-01

    Results of leach tests with Tc-99 doped SRP borosilicate waste glass are presented. The glass was prepared by melting a mixture of SRP 165 powdered frit doped with a carrier free solution of Tc-99 at 1150 0 C. Dissolution of portions of the resulting glass indicated that the Tc-99 was distributed homogeneously throughout the glass. Static leach tests up to 90 days were performed at 90 0 C in J-13 tuff groundwater or WIPP brine A at a SA/V of 100m -1 . Normalized mass losses were calculated for Tc-99 as well as all the major elements in the glass. Results indicated that under ambient oxidizing conditions Tc-99 leached no faster than the glass-forming elements of the glass. In J-13 water, Tc-99 leached congruently with B. In WIPP brine A, it leached congruently with Si. Leach rates for Li were higher in both groundwaters, probably due to a contribution from an ion exchange mechanism. Leach tests were performed under reducing conditions in J-13 water by adding Zn/Hg amalgam to the leachate. In these tests the pH increased significantly, probably because of the reaction of the amalgam with the water. In a 21-day test, the pH increased to 13 and leach rates for the glass were very high. Even though there was signifcant dissolution of the glass, the normalized mass loss based on Tc-99 was only 0.02g/m 2 . This result and the fact that reducing conditions at normal pH values do not significantly affect the dissolution of the glass, indicate that the low concentrations for Tc-99 obtained under reducing conditions are due to is solubility and not due to an increased durability of the glass. 14 refs., 2 figs., 5 tabs

  20. Static leaching of uraniferous shales on open areas

    International Nuclear Information System (INIS)

    Hernandez Nieto, J.; Cordero, G.; Villarrubia, M.

    1973-01-01

    This report describes the tests on acid heap leaching with conventional (1.400 ppm U 3 O 8 ) crushed uranium ores. We use open circuits with low internal recycled. Using starving acidity in the leaching solutions we obtain a smooth solubilization of uranium and, at the same time, the pregnant liquors are good for the solvent extraction recovery. (Author)

  1. Variability of concrete properties: experimental characterisation and probabilistic modelling for calcium leaching

    International Nuclear Information System (INIS)

    De Larrard, Th.

    2010-09-01

    Evaluating structures durability requires taking into account the variability of material properties. The thesis has two main aspects: on the one hand, an experimental campaign aimed at quantifying the variability of many indicators of concrete behaviour; on the other hand, a simple numerical model for calcium leaching is developed in order to implement probabilistic methods so as to estimate the lifetime of structures such as those related to radioactive waste disposal. The experimental campaign consisted in following up two real building sites, and quantifying the variability of these indicators, studying their correlation, and characterising the random fields variability for the considered variables (especially the correlation length). To draw any conclusion from the accelerated leaching tests with ammonium nitrate by overcoming the effects of temperature, an inverse analysis tool based on the theory of artificial neural networks was developed. Simple numerical tools are presented to investigate the propagation of variability in durability issues, quantify the influence of this variability on the lifespan of structures and explain the variability of the input parameters of the numerical model and the physical measurable quantities of the material. (author)

  2. Leaching behavior of microtektite glass compositions in sea water and the effect of precipitation on glass leaching

    International Nuclear Information System (INIS)

    1991-01-01

    In the present study it was attempted to account for the slow corrosion rates of microtektite glass in nature by comparing the leach rates of synthetic microtektite glass samples in deionized water and in sea-water, respectively. In order to obtain systematic data about leachant composition effects, leach tests were also carried out with synthetic leachant compositions enriched with respect to silica or depleted with respect to certain major components of sea-water (Mg, Ca). 47 refs., 1 fig., 5 tabs

  3. Accelerators for Society - TIARA 2012 Test Infrastructure and Accelerator Research Area (in Polish)

    CERN Document Server

    Romaniuk, R S

    2013-01-01

    TIARA (Test Infrastructure and Accelerator Research Area - Preparatory Phae) is an European Collaboration of Accelerator Technology, which by running research projects, technical, networks and infrastructural has a duty to integrate the research and technical communities and infrastructures in the global scale of Europe. The Collaboration gathers all research centers with large accelerator infrastructures. Other ones, like universities, are affiliated as associate members. TIARA-PP (preparatory phase) is an European infrastructural project run by this Consortium and realized inside EU-FP7. The paper presents a general overview of TIARA activities, with an introduction containing a portrait of contemporary accelerator technology and a digest of its applications in modern society.

  4. Leaching Environmental Assessment Framework to Evaluate Beneficial Use and Disposal Decisions

    Science.gov (United States)

    LEAF test methods are available for use to characterize the leaching potential over a range of conditions (i.e., pH, liquid-to-solid ratio, and waste form). LEAF characterization tests can be used to evaluate a range of materials to identify leaching behavior across a range of ...

  5. Development of a 20 MeV Dielectric-Loaded Accelerator Test Facility

    International Nuclear Information System (INIS)

    Gold, Steven H.; Fliflet, Arne W.; Kinkead, Allen K.; Gai Wei; Power, John G.; Konecny, Richard; Jing Chunguang; Tantawi, Sami G.; Nantista, Christopher D.; Hu, Y.; Chen, H.; Tang, C.; Lin, Y.; Bruce, Ralph W.; Bruce, Robert L.; Lewis, David III

    2004-01-01

    This paper describes a joint project by the Naval Research Laboratory (NRL) and Argonne National Laboratory (ANL), in collaboration with the StanFord Linear Accelerator Center (SLAC), to develop a dielectric-loaded accelerator (DLA) test facility powered by a high-power 11.424-GHz magnicon amplifier. The magnicon can presently produce 25 MW of output power in a 250-ns pulse at 10 Hz, and efforts are in progress to increase this to 50 MW. The facility will include a 5 MeV electron injector being developed by the Accelerator Laboratory of Tsinghua University in Beijing, China. The DLA test structures are being developed by ANL, and some have undergone testing at NRL at gradients up to ∼8 MV/m. SLAC is developing a means to combine the two magnicon output arms, and to drive an injector and accelerator with separate control of the power ratio and relative phase. RWBruce Associates, Inc., working with NRL, is developing a means to join short ceramic sections into a continuous accelerator tube by ceramic brazing using an intense millimeter-wave beam. The installation and testing of the first dielectric-loaded test accelerator, including injector, DLA structure, and spectrometer, should take place within the next year. The facility will be used for testing DLA structures using a variety of materials and configurations, and also for testing other X-band accelerator concepts. The initial goal is to produce a compact 20 MeV dielectric-loaded test accelerator

  6. Leaching of RA-226 contaminated gravel using different aqueous treatments

    Energy Technology Data Exchange (ETDEWEB)

    Mamoon, A; Abulfaraj, W H; Sohsah, M A [King Abdulaziz University, Jeddah, Saudi Arbabia (Saudi Arabia)

    1997-12-31

    Investigation of the efficiencies of different aqueous leaching treatments was carried out on gravel artificially contaminated with Ra-226. The extent of leaching efficiency was determined in terms of Ra-226 and its daughter Rn-222. Liquid scintillation counting using high efficiency mineral oil based liquid scintillator was the technique adopted for measuring Ra-226 and Rn-222 leached off the contaminated gravel. Water, dilute solutions of barium chloride and HCl were used as leachants. Different masses of gravel were leached with 200 mL of leachant for various contact time periods. The leached Rn-222 activity measured was plotted vs the decay factor e; from which Rn-222 and Ra-226 originally present in the sample were determined. Several leaching parameters were tested; namely type of leachant, leachant volume/gravel mass ratio, leachant contact time, effect of varying Ba Cl{sub 2} concentration, and successive leaching. Optimization of the leaching parameters for desorption of Ra-226 off the contaminated gravel under laboratory conditions may help determine the ideal conditions for remediating soil contaminated with radium or chemically similar radionuclides. 7 figs.

  7. Operation of the graded-β electron test accelerator

    International Nuclear Information System (INIS)

    Fraser, J.S.; McKeown, J.; McMichael, G.E.; Diamond, W.T.

    1976-01-01

    The Electron Test Accelerator has been built to model the behaviour of the high energy portion of a proton linear accelerator which would be suitable for breeding fissile material. The test accelerator and its control systems have been tested at 100% duty factor producing a beam of electrons at 1.5 MeV and currents up to 20 mA where the incident rf power is shared equally between the structure dissipation and the beam loading. The structure has performed satisfactorily in all respects at dissipation power densities up to 5 kW/cell where the mean energy gradient was 1.1 MeV/m. Experiments have been done on the beam loading effects in the coupling of the transmission line to the cavity, the amplitude depression in and phase tilt along the structure, and the phase lag of the structure field. The phase acceptance, the variation of transmission with buncher-accelerator phase shift and the beam energy spread are in qualitative agreement with beam dynamics calculations. (author)

  8. [Mixture Leaching Remediation Technology of Arsenic Contaminated Soil].

    Science.gov (United States)

    Chen, Xun-feng; Li, Xiao-ming; Chen, Can; Yang, Qi; Deng, Lin-jing; Xie, Wei-qiang; Zhong, Yui; Huang, Bin; Yang, Wei-qiang; Zhang, Zhi-bei

    2016-03-15

    Soil contamination of arsenic pollution has become a severely environmental issue, while soil leaching is an efficient method for remediation of arsenic-contaminated soil. In this study, batch tests were primarily conducted to select optimal mixture leaching combination. Firstly, five conventional reagents were selected and combined with each other. Secondly, the fractions were analyzed before and after the tests. Finally, to explore the feasibility of mixed leaching, three soils with different arsenic pollution levels were used to compare the leaching effect. Comparing with one-step washing, the two-step sequential washing with different reagents increased the arsenic removal efficiency. These results showed that the mixture of 4 h 0.5 mol · L⁻¹ NaOH + 4 h 0.1 mol · L⁻¹ EDTA was found to be practicable, which could enhance the removal rate of arsenic from 66.67% to 91.83%, and the concentration of arsenic in soil was decreased from 186 mg · kg⁻¹ to 15.2 mg · kg⁻¹. Furthermore, the results indicated that the distribution of fractions of arsenic in soil changed apparently after mixture leaching. Leaching process could significantly reduce the available contents of arsenic in soil. Moreover, the mixture of 0.5 mol · L⁻¹ NaOH + 0.1 mol L⁻¹ EDTA could well decrease the arsenic concentration in aluminum-type soils, while the mixture of 0.5 mol · L⁻¹ OX + 0.5 mol · L⁻¹ NaOH could well decrease the arsenic concentration in iron-type soils.

  9. Antimony smelting process generating solid wastes and dust: characterization and leaching behaviors.

    Science.gov (United States)

    Guo, Xuejun; Wang, Kunpeng; He, Mengchang; Liu, Ziwei; Yang, Hailin; Li, Sisi

    2014-07-01

    A large amount of solid waste has been produced by the antimony smelting process in the "World Capital of Antimony", Xikuangshan area in China. This study comprehensively investigated the physical and chemical characteristics of the various solid wastes, as well as the leaching behavior of the solid wastes, which included water-quenched slag, arsenic-alkali residue, desulfurized slag and blast furnace dust. These four types of waste were enriched in a variety of heavy metals and metalloids and more specifically with As and Sb levels up to 8.6 × 10⁴ and 3.16×10⁵ mg/kg, respectively, in arsenic-alkali residue. For desulfurized slag and water-quenched slag, the leaching concentration of Sb significantly exceeded the acceptable limits during the leaching tests using the toxicity characteristic leaching procedure and the synthetic precipitation leaching procedure. In addition, As leaching in arsenic-alkali residue was extraordinarily hazardous, being three orders of magnitude higher than the regulatory level of As. According to the results of the extraction tests, all the tested wastes were classified as hazardous waste. Copyright © 2014. Published by Elsevier B.V.

  10. An experimental survey of the factors that affect leaching from low-level radioactive waste forms

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Pietrzak, R.F.; Fuhrmann, M.; Colombo, P.

    1988-09-01

    This report represents the results of an experimental survey of the factors that affect leaching from several types of solidified low-level radioactive waste forms. The goal of these investigations was to determine those factors that accelerate leaching without changing its mechanism(s). Typically, although not in every case,the accelerating factors include: increased temperature, increased waste loading (i.e., increased waste to binder ratio), and decreased size (i.e., decreased waste form volume to surface area ratio). Additional factors that were studied were: increased leachant volume to waste form surface area ratio, pH, leachant composition (groundwaters, natural and synthetic chelating agents), leachant flow rate or replacement frequency and waste form porosity and surface condition. Other potential factors, including the radiation environment and pressure, were omitted based on a survey of the literature. 82 refs., 236 figs., 13 tabs

  11. In-situ uranium leaching

    International Nuclear Information System (INIS)

    Dotson, B.J.

    1986-01-01

    This invention provides a method for improving the recovery of mineral values from ore bodies subjected to in-situ leaching by controlling the flow behaviour of the leaching solution. In particular, the invention relates to an in-situ leaching operation employing a foam for mobility control of the leaching solution. A foam bank is either introduced into the ore bed or developed in-situ in the ore bed. The foam then becomes a diverting agent forcing the leaching fluid through the previously non-contacted regions of the deposit

  12. Leaching and geochemical behavior of fired bricks containing coal wastes.

    Science.gov (United States)

    Taha, Yassine; Benzaazoua, Mostafa; Edahbi, Mohamed; Mansori, Mohammed; Hakkou, Rachid

    2018-03-01

    High amounts of mine wastes are continuously produced by the mining industry all over the world. Recycling possibility of some wastes in fired brick making has been investigated and showed promising results. However, little attention is given to the leaching behavior of mine wastes based fired bricks. The objective of this paper is to evaluate the geochemical behavior of fired bricks containing different types of coal wastes. The leachates were analyzed for their concentration of As, Ba, Cd, Co, Cr, Cu, Mo, Ni, Pb, Zn and sulfates using different leaching tests; namely Tank Leaching tests (NEN 7375), Toxicity Characteristic Leaching Procedure (TCLP) and pH dependence test (EPA, 1313). The results showed that the release of constituents of potential interest was highly reduced after thermal treatment and were immobilized within the glassy matrix of the fired bricks. Moreover, it was also highlighted that the final pH of all fired samples changed and stabilized around 8-8.5 when the initial pH of leaching solution was in the range 2.5-11.5. The release of heavy metals and metalloids (As) tended to decrease with the increase of pH from acidic to alkaline solutions while Mo displayed a different trend. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Study the Effect of Intermittent and Continuous Ponding Depths by Using Different Heads to Leach Water

    Directory of Open Access Journals (Sweden)

    Nesrin J. AL-Mansori

    2018-03-01

    Full Text Available As results of using water for irrigated lands in a random manner in a time of shortage main water resources, Experimental work carried out to study the effect of continuous and intermittent ponding depth on the leaching processes. Sandy soil used, sourced from Hilla / Al-Jameeya, at Hilla city. Sieve analysis and hydrometer testing used to identify the properties of the soil. A model used with dimensions of 30, 30 and, 70 cm, with two different heads of water. Shatt-Al-Hilla River samples used in the leaching process.   Chemical tests carried out before the leaching process to identify changes in the proprieties in both water and soil. Leachate collected from two soil columns drained into boxes and tests carried out every 30 minutes. After the leaching process was complete, the soil was re-tested. Chemical tests on soil samples and the collected water applied after leaching for 47.5 cm and 52.5cm heads. From the results،, it can be notice that electrical conductivity for the outlet discharge from soil samples decreased faster with time, then slowing down until the end of leaching process.  The same pattern can be seen for all soil properties. In continuous leaching, a large quantity of water is required over a short leaching period, the inverse true for intermittent leaching. All parameters reduce with time in continuous leaching in comparison to intermittent leaching but when the water level in the soil column compared, it can inferred that increasing the head will reduce all the parameters for soil.

  14. The effects of types of media on uranium leaching using metabolite of Aspergillus niger

    International Nuclear Information System (INIS)

    Li Guangyue; Ding Dexin; Wang Yongdong; Hu Nan

    2012-01-01

    To investigate the influences of different media to uranium leaching applying with metabolite of Aspergillus niger, PSA and glucose-steepwater medium were used for the culture of Aspergillus niger, and the metabolite of Aspergillus niger with different pH value produced in the diverse culture temperature were obtained which was applied on the tests of uranium leaching as leaching agent. The test results show that the maximum leaching rate is 83.05% when the leaching agent is the metabolite of Aspergillus niger produced by PSA, as for the glucose- steepwater medium, the maximum leaching rate is 68.20%. The pH value of the metabolite of Aspergillus niger of the two kinds of media has a significant effect on the leaching rate. When PSA is adopted, the best leaching rate appears at the pH value of metabolite ranging from 2.0 to 2.5, and as for the glucose-steepwater medium, the pH value is below 2.1. (authors)

  15. Taoshan uranium ore fields in situ blasting heap leaching rate influence factors to investigate

    International Nuclear Information System (INIS)

    Xie Wangnan; Dong Chunming

    2014-01-01

    Taoshan ore field ore in situ blasting heap leaching out build industrial test and production process, stope leaching rate and leaching cycle is large than that, after analysis, blasting method and cloth liquid way is to affect leaching rate and leaching cycle of the main factors. This paper holds that as far as possible using stratified deep hole blasting of squeezing up ways to reduce the building pile of in-situ leaching ore block rate; Adopting effective cloth tube way, increase the leaching agent and ore contact comprehensive; Introduction of bacterial leaching, and other means to improve leaching rate, shorten production cycle, etc to solve it. (authors)

  16. Presence and leaching of bisphenol a (BPA) from dental materials

    Science.gov (United States)

    Becher, Rune; Wellendorf, Hanne; Sakhi, Amrit Kaur; Samuelsen, Jan Tore; Thomsen, Cathrine; Bølling, Anette Kocbach; Kopperud, Hilde Molvig

    2018-01-01

    Abstract BPA has been reported to leach from some resin based dental restorative materials and materials used for orthodontic treatment. To confirm and update previous findings, especially in light of the new temporary lower threshold value for tolerable daily BPA intake, we have investigated the leaching of BPA from 4 composite filling materials, 3 sealants and 2 orthodontic bonding materials. The materials were either uncured and dissolved in methanol or cured. The cured materials were kept in deionized water for 24 hours or 2 weeks. Samples were subsequently analyzed by ultra-performance liquid chromatography coupled to mass spectrometry (UPLC-MS-MS). The composite filling material Tetric EvoFlow® and the fissure sealant DELTON® showed significantly higher levels of BPA leaching compared to control samples for all test conditions (uncured, 24 h leaching and 2 weeks leaching). There were no significant differences in amount of leached BPA for any of the tested materials after 24 hours compared to 2 weeks. These results show that BPA is still released from some dental materials despite the general concern about potential adverse effects of BPA. However, the amounts of BPA were relatively low and most likely represent a very small contribution to the total BPA exposure. PMID:29868625

  17. RHIC sextant test: Accelerator systems and performance

    Energy Technology Data Exchange (ETDEWEB)

    Pilat, F.; Trbojevic, D.; Ahrens, L. [and others

    1997-08-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning.

  18. RHIC sextant test: Accelerator systems and performance

    International Nuclear Information System (INIS)

    Pilat, F.; Trbojevic, D.; Ahrens, L.

    1997-01-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning

  19. Recovery of Iron from Pyrolusite Leaching Slag by a Lab-Scale Circulation Process of Oxalic Acid Leaching and Ultraviolet Irradiation

    Directory of Open Access Journals (Sweden)

    Biao Deng

    2017-12-01

    Full Text Available Pyrolusite leaching slag is a Fe-containing slag generated from pyrolusite leaching process with SO2. Recovery of iron from the slag not only has economic benefit, but also prevents the secondary pollution to the environment. A novel lab-scale cyclic process for recovering iron from pyrolusite leaching slag was introduced. The process contains two steps: (1 iron was leached with oxalic acid and [Fe(C2O4n](3−2n+ solution was generated; (2 the [Fe(C2O4n](3−2n+ solution was irradiated by ultraviolet and ferrous oxalate precipitation were obtained. The effect of operation parameter on leaching and irradiation process were studied separately. In the leaching process, the optimal solid/liquid ratio, oxalic acid concentration, leaching temperature, stirring rate, and leaching time are 1:50, 0.40 mol/L, 95 °C, 300 r/min, and 3 h, respectively. In the irradiation process, the best irradiation wavelength, Fe/oxalic acid molar ratio and irradiation time are 254 nm, 1:4, and 30 min. Besides, a test of 9 continuous cycles was carried out and the performance and material balance of the combined process were investigated. The results showed that the cyclic process is entirely feasible and prove to be stable producing, and ferrous oxalate of 99.32% purity. Material balance indicated that 95.17% of iron was recovered in the form of FeC2O4·2H2O, and the recovery efficiency of oxalic acid was 58.52%.

  20. Biocatalytic and chemical leaching of a low-grade nickel laterite ore

    Science.gov (United States)

    Ciftci, Hasan; Atik, Suleyman; Gurbuz, Fatma

    2018-04-01

    Nickel and cobalt recovery from a low-grade nickel laterite ore, supplied from Çaldağ deposit (Manisa, Turkey) were investigated by bio and chemical leaching processes. The fungus, Aspergillus niger was used for biocatalytic leaching experiments. The effects of parameters (solid ratio and sucrose concentration) on the biocatalytic leaching of the ore were initially tested in flasks to obtain the optimum conditions for the A. niger. Then chemical leaching was applied as a comparison to bioleaching, using organic acids (citric, oxalic, acetic and gluconic acids) as well as a mixture of acids. According the results, the maximum dissolution yield of nickel, cobalt and iron were detected respectively as 95.3%, 74.3% and 50.0% by biocatalytic processes which containing 25% (w/v) sucrose and 1% (w/v) solids. The increase in the solid ratio adversely influenced the biocatalytic activity of A. niger. Finally, further tests in reactors (v = 1 and 10 L) were performed using the optimum conditions from the flask tests. The difference in metals recovery between biocatalytic and chemical leaching was significantly important. Bioleaching produced higher Ni and Co extractions (34.3-75.6%) than chemical process.

  1. Cadmium telluride leaching behavior: Discussion of Zeng et al. (2015).

    Science.gov (United States)

    Sinha, Parikhit

    2015-11-01

    Zeng et al. (2015) evaluate the leaching behavior and surface chemistry of II-VI semiconductor materials, CdTe and CdSe, in response to pH and O2. Under agitation in acidic and aerobic conditions, the authors found approximately 3.6%-6.4% (w/w) solubility of Cd content in CdTe in the Toxicity Characteristic Leaching Procedure (TCLP), Waste Extraction Test (WET), and dissolution test, with lower solubility (0.56-0.58%) under agitation in acidic and anoxic conditions. This range is comparable with prior long-term transformation and dissolution testing and bio-elution testing of CdTe (2.3%-4.1% w/w solubility of Cd content in CdTe). The implications for potential leaching behavior of CdTe-containing devices require further data. Since CdTe PV modules contain approximately 0.05% Cd content by mass, the starting Cd content in the evaluation of CdTe-containing devices would be lower by three orders of magnitude than the starting Cd content in the authors' study, and leaching potential would be further limited by the monolithic glass-adhesive laminate-glass structure of the device that encapsulates the semiconductor material. Experimental evaluation of leaching potential of CdTe PV modules crushed by landfill compactor has been conducted, with results of TCLP and WET tests on the crushed material below regulatory limits for Cd. CdTe PV recycling technology has been in commercial operation since 2005 with high yields for semiconductor (95%) and glass (90%) recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Irradiation effect on leaching behavior and form of heavy metals in fly ash of municipal solid waste incinerator

    International Nuclear Information System (INIS)

    Nam, Sangchul; Namkoong, Wan

    2012-01-01

    Highlights: ► No research has been done to examine effect of electron beam irradiation on leaching behavior of heavy metals in fly ash. ► Electron beam irradiation on fly ash had significant effect on heavy metal leaching. ► Leaching potential of heavy metals in fly ash differed among metal species tested (Pb, Zn, Cu). ► Metal forms in the ash were analyzed to explain the difference. ► The difference could be explained by metal form change. - Abstract: Fly ash from a municipal solid waste incinerator (MSWI) is commonly classified as hazardous waste. High-energy electron beam irradiation systems have gained popularity recently as a clean and promising technology to remove environmental pollutants. Irradiation effects on leaching behavior and form of heavy metals in MSWI fly ash have not been investigated in any significant detail. An electron beam accelerator was used in this research. Electron beam irradiation on fly ash significantly increased the leaching potential of heavy metals from fly ash. The amount of absorbed dose and the metal species affected leaching behavior. When electron beam irradiation intensity increased gradually up to 210 kGy, concentration of Pb and Zn in the leachate increased linearly as absorbed dose increased, while that of Cu underwent no significant change. Concentration of Pb and Zn in the leachate increased up to 15.5% (10.7 mg/kg), and 35.6% (9.6 mg/kg) respectively. However, only 4.8% (0.3 mg/kg) increase was observed in the case of Cu. The results imply that irradiation has significant effect on the leaching behavior of heavy metals in fly ash, and the effect is quite different among the metal species tested in this study. A commonly used sequential extraction analysis which can classify a metal species into five forms was conducted to examine any change in metal form in the irradiated fly ash. Notable change in metal form in fly ash was observed when fly ash was irradiated. Change in Pb form was much greater than that of

  3. Laboratory study on leaching of a sandstone-type uranium deposit for acid in-situ leaching

    International Nuclear Information System (INIS)

    Wen Zhenqian; Yao Yixuan; Zheng Jianping; Jiang Yan; Cui Xin; Xing Yongguo; Hao Jinting; Tang Huazhang

    2013-01-01

    Ore samples were took from in-situ leaching experiment boreholes in a sandstone-type uranium deposit. Technological mineralogy study, agitating leaching and column leaching experiments were carried. The results show that the content of minerals consuming acid and deoxidized minerals is low. When sulfuric acid concentration was 1O g/L, initial uranium content was 0.0224%, and liquid-to-solid ratio was l.91, leaching rate of column leaching experiments is 89.19%, acid consumption is 8.2 kg/t ore, acid consumption is 41.88 t/tU. Acid leaching, technology is recommend for field in-situ leaching experiment, sulfuric acid concentration in confecting solution is 10 g/L, and oxidizing agent is needless during leaching process. (authors)

  4. Quick setup of test unit for accelerator control system

    International Nuclear Information System (INIS)

    Fu, W.; D'Ottavio, T.; Gassner, D.; Nemesure, S.; Morris, J.

    2011-01-01

    Testing a single hardware unit of an accelerator control system often requires the setup of a program with graphical user interface. Developing a dedicated application for a specific hardware unit test could be time consuming and the application may become obsolete after the unit tests. This paper documents a methodology for quick design and setup of an interface focused on performing unit tests of accelerator equipment with minimum programming work. The method has three components. The first is a generic accelerator device object (ADO) manager which can be used to setup, store, and log testing controls parameters for any unit testing system. The second involves the design of a TAPE (Tool for Automated Procedure Execution) sequence file that specifies and implements all te testing and control logic. The sting third is the design of a PET (parameter editing tool) page that provides the unit tester with all the necessary control parameters required for testing. This approach has been used for testing the horizontal plane of the Stochastic Cooling Motion Control System at RHIC.

  5. Accelerated testing of composites

    Science.gov (United States)

    Papazian, H. A.

    1983-01-01

    It is shown that the Zhurkov method for testing the strength of solids can be applied to dynamic tension and to cyclic loading and provides a viable approach to accelerated testing of composites. Data from the literature are used to demonstrate a straightforward application of the method to dynamic tension of glass fiber and cyclic loading for glass/polymer, metal matrix, and graphite/epoxy composites. Zhurkov's equation can be used at relatively high loads to obtain failure times at any temperature of interest. By taking a few data points at one or two other temperatures the spectrum of failure times can be expanded to temperatures not easily accessible.

  6. Leaching of nuclear power reactor waste forms

    International Nuclear Information System (INIS)

    Endo, L.S.; Villalobos, J.P.; Miyamoto, H.

    1987-01-01

    The leaching tests for immobilized power reactor wastes carried out at IPEN are described. These wastes forms consist mainly of spent resins and boric acid concentrates solidified in ordinary Portland cement. All tests were conducted according to the ISO and IAEA recommendations. Three years leaching results are reported. The cesium diffuvity coefficients determined out of these results are about 1 x 10 -8 cm 2 /s for boric acid waste form and 9 x 10 -9 cm 2 /s for ion-exchange resin waste. Strontium diffusivity coefficients found are about 3 x 10 -11 cm 2 /s and 9 x 10 -11 cm 2 /s respectively. (Author) [pt

  7. Alkaline Leaching of Low Zinc Content Iron-Bearing Sludges

    Directory of Open Access Journals (Sweden)

    Gargul K.

    2016-03-01

    Full Text Available Various types of waste materials containing zinc (e.g. dusts and sludges from gas dedusting process are obtained in steel industry. The contents of Zn in these materials may vary considerably. Even a low concentration of zinc in recirculated products precludes their recycling in ferrous metallurgy aggregates. Long storage of this type of material can lead to contamination of soil and water by zinc compounds which can be leached out by acid rain, for example. This paper focuses on research involving alkaline leaching tests of low zinc content iron-bearing materials. These tests were preceded by the analysis of the elemental, phase and grain size composition, and analysis of the thermodynamic conditions of the leaching process. The main aim of research was to decrease the content of the zinc in the sludge to the level where it is suitable as an iron-bearing material for iron production (~1% Zn. Leaching at elevated temperatures (368 K, 60 min has led to a decrease in the zinc content in the sludge of about 66%. The research revealed that long hour leaching (298 K, 100 hours carried out at ambient temperatures caused a reduction in zinc content by 60% to the value of 1.15-1.2% Zn.

  8. Leach behavior of high-level borosilicate glasses under deep geological environment

    International Nuclear Information System (INIS)

    Kim, Seung Soo; Chun, Kwan Sik; Park, Hyun Soo

    1998-02-01

    This report presents an overview of the activities in high-level radioactive waste glass which is considered as the most practicable form of waste, and also is intended to be used in the disposal of national high-level radioactive waste in future. Leach theory of waste glass and the leach effects of ground water, metal barrier, buffer materials and rocks on the waste glass were reviewed. The leach of waste glass was affected by various factors such as composition, pH and Eh of ground water, temperature, pressure, radiation and humic acid. The crystallization, crack, weathering and the formation of altered phases of waste glass which is expected to occur in real disposal site were reviewed. The results of leaching in laboratory and in-situ were compared. The behaviors of radioactive elements leached from waste glass and the use of basalt glass for the long-term natural analogue of waste glass were also written in this report. The appraisal of durability of borosilicate waste glass as a waste media was performed from the known results of leach test and international in-situ tests were introduced. (author). 134 refs., 15 tabs., 24 figs

  9. Study on the leaching behavior of actinides from nuclear fuel debris

    Science.gov (United States)

    Kirishima, Akira; Hirano, Masahiko; Akiyama, Daisuke; Sasaki, Takayuki; Sato, Nobuaki

    2018-04-01

    For the prediction of the leaching behavior of actinides contained in the nuclear fuel debris generated by the Fukushima Daiichi nuclear power plant accident in Japan, simulated fuel debris consisting of a UO2-ZrO2 solid solution doped with 137Cs, 237Np, 236Pu, and 241Am tracers was synthesized and investigated. The synthesis of the debris was carried out by heat treatment at 1200 °C at different oxygen partial pressures, and the samples were subsequently used for leaching tests with Milli-Q water and seawater. The results of the leaching tests indicate that the leaching of actinides depends on the redox conditions under which the debris was generated; for example, debris generated under oxidative conditions releases more actinide nuclides to water than that generated under reductive conditions. Furthermore, we found that, as Zr(IV) increasingly substituted U(IV) in the fluorite crystal structure of the debris, the actinide leaching from the debris decreased. In addition, we found that seawater leached more actinides from the debris than pure water, which seems to be caused by the complexation of actinides by carbonate ions in seawater.

  10. Preloading To Accelerate Slow-Crack-Growth Testing

    Science.gov (United States)

    Gyekenyesi, John P.; Choi, Sung R.; Pawlik, Ralph J.

    2004-01-01

    An accelerated-testing methodology has been developed for measuring the slow-crack-growth (SCG) behavior of brittle materials. Like the prior methodology, the accelerated-testing methodology involves dynamic fatigue ( constant stress-rate) testing, in which a load or a displacement is applied to a specimen at a constant rate. SCG parameters or life prediction parameters needed for designing components made of the same material as that of the specimen are calculated from the relationship between (1) the strength of the material as measured in the test and (2) the applied stress rate used in the test. Despite its simplicity and convenience, dynamic fatigue testing as practiced heretofore has one major drawback: it is extremely time-consuming, especially at low stress rates. The present accelerated methodology reduces the time needed to test a specimen at a given rate of applied load, stress, or displacement. Instead of starting the test from zero applied load or displacement as in the prior methodology, one preloads the specimen and increases the applied load at the specified rate (see Figure 1). One might expect the preload to alter the results of the test and indeed it does, but fortunately, it is possible to account for the effect of the preload in interpreting the results. The accounting is done by calculating the normalized strength (defined as the strength in the presence of preload the strength in the absence of preload) as a function of (1) the preloading factor (defined as the preload stress the strength in the absence of preload) and (2) a SCG parameter, denoted n, that is used in a power-law crack-speed formulation. Figure 2 presents numerical results from this theoretical calculation.

  11. Carbonate heap leach of uranium-contaminated soils

    International Nuclear Information System (INIS)

    Turney, W.R.; Mason, C.F.V.; Longmire, P.

    1994-01-01

    A new approach to removal of uranium from soils based on existing heap leach mining technologies proved highly effective for remediation of soils from the Fernald Environmental Management Project (FEMP) near Cincinnati, Ohio. In laboratory tests, remediation of uranium-contaminated soils by heap leaching with carbonate salt solutions was demonstrated in column experiments. An understanding of the chemical processes that occur during carbonate leach of uranium from soils may lead to enhancement of uranium removal. Carbonate leaching requires the use of an integrated and closed circuit process, wherein the leach solutions are recycled and the reagents are reused, resulting in a minimum secondary waste stream. Carbonate salt leach solution has two important roles. Primarily, the formation of highly soluble anionic carbonate uranyl species, including uranyl dicarbonate (UO 2 CO 32 = ) and uranyl tricarbonate (UO 2 CO 33 4- ), allows for high concentration of uranium in a leachate solution. Secondly, carbonate salts are nearly selective for dissolution of uranium from uranium contaminated soils. Other advantages of the carbonate leaching process include (1) the high solubility, (2) the selectivity, (3) the purity of the solution produced, (4) the relative ease with which a uranium product can be precipitated directly from the leachate solution, and (5) the relatively non-corrosive and safe handling characteristics of carbonate solutions. Experiments conducted in the laboratory have demonstrated the effectiveness of carbonate leach. Efficiencies of uranium removal from the soils have been as high as 92 percent. Higher molar strength carbonate solutions (∼0.5M) proved more effective than lower molar strength solutions (∼ 0.1M). Uranium removal is also a function of lixiviant loading rate. Furthermore, agglomeration of the soils with cement resulted in less effective uranium removal

  12. Microwave Pretreatment for Thiourea Leaching for Gold Concentrate

    Directory of Open Access Journals (Sweden)

    Nag-Choul Choi

    2017-10-01

    Full Text Available In this research, we studied the use of microwave pretreatment to enhance the efficiency of Au leaching from gold concentrate. The gold concentrate was pretreated using microwaves with different irradiation time. The sample temperature was increased up to 950 °C by the microwave irradiation. A scanning electron microscope-energy dispersive spectrometer showed the evolution of microcracks and the reduction of sulfur on the mineral surface. X-ray diffraction data also showed the mineral phase shift from pyrite to hematite or pyrrhotite. A leaching test was conducted for the microwave-treated and untreated gold concentrates using thiourea. Although the thiourea leaching recovered 80% of Au from the untreated concentrate, from the treated concentration, the Au could be recovered completely. Au leaching efficiency increased as the microwave irradiation time increased, as well as with a higher composition of thiourea.

  13. Long-term leaching behavior of simulated Savannah River Plant waste glass: Part 1, MCC-1 leachability results, four-year leaching data

    International Nuclear Information System (INIS)

    Wicks, G.G.; Stone, J.A.; Chandler, G.T.; Williams, S.

    1986-08-01

    Long-term leaching data were obtained on SRP 131/TDS waste glass using MCC-1 or slightly modified MCC-1 standard leaching tests. Experiments were conducted out to four years at 40 0 C and 3-1/2 years at 90 0 C. These experiments have produced the longest standardized leaching data currently available in the waste management community. Long-term leaching data provide important input to modeling of waste glass behavior and ultimate prediction of waste glass performance. In this study, the leaching behavior of SRP waste glass was found to be excellent; leachates based on a variety of elements were not only very low, but also improved with increasing time. In addition to these data, results are also reported from another independent Savannah River study. Leaching behavior at 40 0 C and 90 0 C was assessed not only for a similar SRP 131 waste glass composition, but also for extreme waste glass compositions involving high-iron and high-aluminum waste. In addition, these experiments were performed using not only a standard deionized water leachant, but also simplified brine and silicate groundwater simulations. These two large data bases will be summarized and correlated along with some of the more interesting results recently reported in another study, a two-year leaching program performed on a similar SRP waste glass composition at Battelle Pacific Northwest Laboratories

  14. Heap leaching for uranium

    International Nuclear Information System (INIS)

    1988-01-01

    Denison Mines Ltd. is using two bacterial leaching processes to combat the high cost of extracting uranium from low grade ore in thin reefs. Both processes use thiobacillus ferro-oxidans, a bacterium that employs the oxidation of ferrous iron and sulphur as its source of energy for growth. The first method is flood leaching, in which ore is subjected to successive flood, drain and rest cycles. The second, trickle leaching, uses sprinklers to douse the broken muck continuously with leaching solution. In areas where grades are too low to justify the expense of hauling the ore to the surface, the company is using this biological process underground to recover uranium. In 1987 Denison recovered 840 000 lb of uranium through bacterial heap leaching. It plans to have biological in-place leaching contribute 25% of the total uranium production by 1990. (fig.)

  15. Reduction of water consumption in the dynamic acid leaching process of uranium

    International Nuclear Information System (INIS)

    Chocron, M.; Arias, M.J.; Avato, A.M.; Díaz, V.A.

    2013-01-01

    In 2006 the Argentine state announced a plan to reactivate the nuclear sector. As a result of this decision, the National Atomic Energy Commission (CNEA) resumed its research in uranium mining for Argentine deposits. The first step was the study of the leaching process, mainly the dynamic leaching. In this work the influence of the reduction of the water content in the dynamic leaching process in acid medium, at laboratory scale and under batch operating conditions, on the main operating parameters (concentration of the leaching reagent, the oxidizing reagent and The reaction temperature). The percentages of pulp solids studied in the dynamic leaching were 53% and 66% w / w. For the tests uranium-molybdenum ores of the sandstone type were used. Two different working schemes were used to study the different operating parameters. In the tests carried out with 53% of solid in pulp, the parameters were studied individually (varying one parameter at a time), while working with a pulp of 66% solids, the study of the parameters was performed by a Factorial design of two levels of three variables, which in addition to studying the dependence of the different parameters allowed to analyze how they influence each other. During the leaching tests with 66% solids content in pulp, changes in the geometric and dynamic conditions of the system were necessary because of the poor mixing observed when using the same agitation conditions used in the leaching tests with 53% solids in pulp. When comparing the tests for both solids content conditions (53% and 66% w / w), similar extraction yields were observed for both uranium and molybdenum (more than 90% for uranium and more than 80% for The molybdenum). As a final result, the process water consumption (380 liters of water per ton of ore) is reduced by more than 50% by working with pulps of 66% w / w of solids, obtaining acceptable extraction yields and, as an additional, reducing The consumption of the leaching reagent. (author)

  16. Effects of Leaching Behavior of Calcium Ions on Compression and Durability of Cement-Based Materials with Mineral Admixtures

    Science.gov (United States)

    Cheng, An; Chao, Sao-Jeng; Lin, Wei-Ting

    2013-01-01

    Leaching of calcium ions increases the porosity of cement-based materials, consequently resulting in a negative effect on durability since it provides an entry for aggressive harmful ions, causing reinforcing steel corrosion. This study investigates the effects of leaching behavior of calcium ions on the compression and durability of cement-based materials. Since the parameters influencing the leaching behavior of cement-based materials are unclear and diverse, this paper focuses on the influence of added mineral admixtures (fly ash, slag and silica fume) on the leaching behavior of calcium ions regarding compression and durability of cemented-based materials. Ammonium nitrate solution was used to accelerate the leaching process in this study. Scanning electron microscopy, X-ray diffraction analysis, and thermogravimetric analysis were employed to analyze and compare the cement-based material compositions prior to and after calcium ion leaching. The experimental results show that the mineral admixtures reduce calcium hydroxide quantity and refine pore structure through pozzolanic reaction, thus enhancing the compressive strength and durability of cement-based materials. PMID:28809247

  17. Standard Operating Procedure for Accelerated Corrosion Testing at ARL

    Science.gov (United States)

    2017-11-01

    ARL-TN-0855 ● NOV 2017 US Army Research Laboratory Standard Operating Procedure for Accelerated Corrosion Testing at ARL by... Corrosion Testing at ARL by Thomas A Considine Weapons and Materials Research Directorate, ARL Approved for public...November 2017 2. REPORT TYPE Technical Note 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Standard Operating Procedure for Accelerated

  18. Leaching experiment of cement solidified waste form under unsaturated condition

    International Nuclear Information System (INIS)

    Wang Zhiming; Yao Laigen; Li Shushen; Zhao Yingjie; Cai Yun; Li Dan; Han Xinsheng; An Yongfeng

    2003-01-01

    A device for unsaturated leaching experiments was designed and built up. 8 different sizes, ranging from 40.2 cm 3 to 16945.5 cm 3 , of solidified waste form were tested in the experiment. 5 different water contents, from 0.15 to 0.40, were used for the experiment. The results show that the cumulative leaching fraction increases with water content when the sizes of the forms are equal to and less than 4586.7 cm 3 , for example, the ratios of the cumulative leaching fractions are between 1.24-1.41 under water content of 0.35 and 0.15 on 360 day of Teaching. It can also be seen that the cumulative leaching fraction under higher water content is close to that under saturated condition. The cumulative leaching fraction decreases with size of the form. Maximum leached depth of the solidified waste forms is about 2.25 cm after one year Teaching. Moreover, it has no clear effect on cumulative leaching fraction that sampling or non-sampling during the experiment

  19. High gradient test of X-band accelerating structure at GLCTA

    International Nuclear Information System (INIS)

    Watanabe, K.; Higo, T.; Hayano, H.; Terunuma, N.; Saeki, T.; Kudo, N.; Sanuki, T.; Seuhara, T.

    2004-01-01

    GLCTA (Global Linear Collider Test Accelerator) is the high power test facility for X-band acceleration. We have installed an X-band 60cm structure in April 2004 and have been processing it for more than 3 months. Now it is under test on long-term operation. We report here the installation process and high power test result to date. (author)

  20. Advanced Beamline Design for Fermilab's Advanced Superconducting Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Christopher [Northern Illinois Univ., DeKalb, IL (United States)

    2014-01-01

    The Advanced Superconducting Test Accelerator (ASTA) at Fermilab is a new electron accelerator currently in the commissioning stage. In addition to testing superconducting accelerating cavities for future accelerators, it is foreseen to support a variety of Advanced Accelerator R&D (AARD) experiments. Producing the required electron bunches with the expected flexibility is challenging. The goal of this dissertation is to explore via numerical simulations new accelerator beamlines that can enable the advanced manipulation of electron bunches. The work especially includes the design of a low-energy bunch compressor and a study of transverse-to-longitudinal phase space exchangers.

  1. Aluminum chloride restoration of in situ leached uranium ores

    International Nuclear Information System (INIS)

    Grant, D.C.; Burgman, M.A.

    1982-01-01

    During in situ uranium mining using ammonium bicarbonate lixiviant, the ammonium exchanges with cations on the ore's clay. After mining is complete, the ammonium may desorb into post-leach ground water. For the particular ore studied, other chemicals (i.e., uranium and selenium) which are mobilized during the leach process, have also been found in the post-leach ground water. Laboratory column tests, used to simulate the leaching process, have shown that aluminum chloride can rapidly remove ammonium from the ore and thus greatly reduce the subsequent ammonium leakage level into ground water. The aluminum chloride has also been found to reduce the leakage levels of uranium and selenium. In addition, the aluminum chloride treatment produces a rapid improvement in permeability

  2. Hydroxylated ceramic waste forms and the absurdity of leach tests

    Energy Technology Data Exchange (ETDEWEB)

    Roy, R; Odoj, R; Merz, E [eds.

    1981-06-01

    The repository pressure and temperature conditions during the thermal period projected in US repositories have been drastically lowered in the last year or two to new values of say 175 +- 50/sup 0/K. Using the argument that the evidence from natural models indicates the most stable mineral (= ceramic) hosts for radionuclides, one finds that under these new repository conditions such crystalline assemblages would be micas, clays, zeolites and other hydrated minerals, plus the tetravalent anhydrous oxide families. A waste form consisting of specific hydroxylated candidate phases can be made via a simple in-can technology (demonstrated by Oak Ridge) by reacting liquid wastes with precursor gels or phyllo or tektosilicates at <200/sup 0/C under modest pressure within the final disposal canister. The data on the rate of reaction of typical oxide materials to yield hydroxylated phases under these conditions show that the typical leach test (at 25 to 100/sup 0/C in deionized water) does not provide a simulation of the reactions which will occur. Hence such tests are not only totally meaningless with respect to qualifying a waste form for its role in a repository, they can be downright misleading.

  3. Hydroxylated ceramic waste forms and the absurdity of 'leach tests'

    Energy Technology Data Exchange (ETDEWEB)

    Roy, R; Odoj, R; Merz, E [eds.

    1981-06-01

    The repository pressure and temperature conditions during the thermal period projected in U.S. repositories have been drastically lowered in the last year or two to new values of say 175 +- 50 K. Using the argument that the evidence from natural models indicates the most stable mineral (= ceramic) hosts for radionuclides, one finds that under these new repository conditions such crystalline assemblages would be micas, clays, zeolites, and other hydrated minerals, plus the tetravalent anhydrous oxide families. A waste form consisting of specific hydroxylated candidate phase can be made via a simple in-can technology (demonstrated by Oak Ridge) by reacting liquid wastes with precursor gels or phyllo or tektosilicates at <200/sup 0/C under modest pressure within the final disposal canister. The data on the rate of reaction of typical oxide materials to yield hydroxylated phases under these conditions show that the typical leach test (at 25-100/sup 0/C in deionized water) does not provide a simulation of the reactions which will occur. Hence such tests are not only totally meaningless with respect to qualifying a waste form for its role in a repository, they can be downright misleading.

  4. NLC. A test accelerator for the next linear collider

    International Nuclear Information System (INIS)

    Ruth, R.D.; Adolphsen, C.; Bane, K.; Boyce, R.F.; Burke, D.L.; Callin, R.; Caryotakis, G.; Cassel, R.; Clark, S.L.; Deruyter, H.; Fant, K.; Fuller, R.; Heifets, S.; Hoag, H.; Humphrey, R.; Kheifets, S.; Koontz, R.; Kroll, N.M.; Lavine, T.; Loew, G.A.; Menegat, A.; Miller, R.H.; Nantista, C.; Paterson, J.M.; Pearson, C.; Phillips, R.; Rifkin, J.; Spencer, J.; Tantawi, S.; Thompson, K.A.; Vlieks, A.; Vylet, V.; Wang, J.W.; Wilson, P.B.; Yeremian, A.; Youngman, B.

    1993-01-01

    At SLAC, we are pursuing the design of a Next Linear Collider (NLC) which would begin with a center-of-mass energy of 0.5 TeV, and be upgradable to at least 1.0 TeV. To achieve this high energy, we have been working on the development of a high-gradient 11.4-GHz (X-band) linear accelerator for the main linac of the collider. In this paper, we present the design of a 'Next Linear Collider Test Accelerator' (NLCTA). The goal of the NLCTA is to incorporate the new technologies of X-band accelerator structures, RF pulse compression systems and klystrons into a short linac which will then be a test bed for beam dynamics issues related to high-gradient acceleration. (orig.)

  5. Operation of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program

  6. Study on Cr(VI) Leaching from Cement and Cement Composites

    Science.gov (United States)

    Palascakova, Lenka; Kanuchova, Maria

    2018-01-01

    This paper reports an experimental study on hexavalent chromium leaching from cement samples and cement composites containing silica fume and zeolite additions that were subjected to various leaching agents. The water-soluble Cr(VI) concentrations in cements ranged from 0.2 to 3.2 mg/kg and represented only 1.8% of the total chromium content. The presence of chromium compounds with both chromium oxidation states of III and VI was detected in the cement samples by X-ray photoelectron spectroscopy (XPS). Leaching tests were performed in a Britton-Robinson buffer to simulate natural conditions and showed increased dissolution of Cr(VI) up to 6 mg/kg. The highest amount of leached hexavalent chromium was detected after leaching in HCl. The findings revealed that the leaching of chromium from cements was higher by 55–80% than that from the cement composites. A minimum concentration was observed for all cement samples when studying the relationship between the soluble Cr(VI) and the cement storage time. PMID:29690550

  7. Some problems in the technique of high-voltage testing of the accelerating tube gaps in electrostatic accelerators

    International Nuclear Information System (INIS)

    Romanov, V.A.; Ivanov, V.V.; Mukhametshin, V.I.; Dmitriev, E.P.; Kidalov, A.I.

    1983-01-01

    Problems arising during high-voltage testing and training of accelerating taubes of electrostatic accelrators are discussed. A rig and technique of the accelerating tube testing and program designed for the processing of the data obtained and sorting out of the samples investigated are described

  8. Characterization, Leaching, and Filtrations Testing of Ferrocyanide Tank sludge (Group 8) Actual Waste Composite

    International Nuclear Information System (INIS)

    Fiskum, Sandra K.; Billing, Justin M.; Crum, J.V.; Daniel, Richard C.; Edwards, Matthew K.; Shimskey, Rick W.; Peterson, Reid A.; MacFarlan, Paul J.; Buck, Edgar C.; Draper, Kathryn E.; Kozelisky, Anne E.

    2009-01-01

    This is the final report in a series of eight reports defining characterization, leach, and filtration testing of a wide variety of Hanford tank waste sludges. The information generated from this series is intended to supplement the Waste Treatment and Immobilization Plant (WTP) project understanding of actual waste behaviors associated with tank waste sludge processing through the pretreatment portion of the WTP. The work described in this report presents information on a high-iron waste form, specifically the ferrocyanide tank waste sludge. Iron hydroxide has been shown to pose technical challenges during filtration processing; the ferrocyanide tank waste sludge represented a good source of the high-iron matrix to test the filtration processing

  9. Characterization, Leaching, and Filtrations Testing of Ferrocyanide Tank sludge (Group 8) Actual Waste Composite

    Energy Technology Data Exchange (ETDEWEB)

    Fiskum, Sandra K.; Billing, Justin M.; Crum, J. V.; Daniel, Richard C.; Edwards, Matthew K.; Shimskey, Rick W.; Peterson, Reid A.; MacFarlan, Paul J.; Buck, Edgar C.; Draper, Kathryn E.; Kozelisky, Anne E.

    2009-02-28

    This is the final report in a series of eight reports defining characterization, leach, and filtration testing of a wide variety of Hanford tank waste sludges. The information generated from this series is intended to supplement the Waste Treatment and Immobilization Plant (WTP) project understanding of actual waste behaviors associated with tank waste sludge processing through the pretreatment portion of the WTP. The work described in this report presents information on a high-iron waste form, specifically the ferrocyanide tank waste sludge. Iron hydroxide has been shown to pose technical challenges during filtration processing; the ferrocyanide tank waste sludge represented a good source of the high-iron matrix to test the filtration processing.

  10. Vacuum system for Advanced Test Accelerator

    International Nuclear Information System (INIS)

    Denhoy, B.S.

    1981-01-01

    The Advanced Test Accelerator (ATA) is a pulsed linear electron beam accelerator designed to study charged particle beam propagation. ATA is designed to produce a 10,000 amp 50 MeV, 70 ns electron beam. The electron beam acceleration is accomplished in ferrite loaded cells. Each cell is capable of maintaining a 70 ns 250 kV voltage pulse across a 1 inch gap. The electron beam is contained in a 5 inch diameter, 300 foot long tube. Cryopumps turbomolecular pumps, and mechanical pumps are used to maintain a base pressure of 2 x 10 -6 torr in the beam tube. The accelerator will be installed in an underground tunnel. Due to the radiation environment in the tunnel, the controlling and monitoring of the vacuum equipment, pressures and temperatures will be done from the control room through a computer interface. This paper describes the vacuum system design, the type of vacuum pumps specified, the reasons behind the selection of the pumps and the techniques used for computer interfacing

  11. Vacuum system for Advanced Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Denhoy, B.S.

    1981-09-03

    The Advanced Test Accelerator (ATA) is a pulsed linear electron beam accelerator designed to study charged particle beam propagation. ATA is designed to produce a 10,000 amp 50 MeV, 70 ns electron beam. The electron beam acceleration is accomplished in ferrite loaded cells. Each cell is capable of maintaining a 70 ns 250 kV voltage pulse across a 1 inch gap. The electron beam is contained in a 5 inch diameter, 300 foot long tube. Cryopumps turbomolecular pumps, and mechanical pumps are used to maintain a base pressure of 2 x 10/sup -6/ torr in the beam tube. The accelerator will be installed in an underground tunnel. Due to the radiation environment in the tunnel, the controlling and monitoring of the vacuum equipment, pressures and temperatures will be done from the control room through a computer interface. This paper describes the vacuum system design, the type of vacuum pumps specified, the reasons behind the selection of the pumps and the techniques used for computer interfacing.

  12. Potential for leaching of arsenic from excavated rock after different drying treatments.

    Science.gov (United States)

    Li, Jining; Kosugi, Tomoya; Riya, Shohei; Hashimoto, Yohey; Hou, Hong; Terada, Akihiko; Hosomi, Masaaki

    2016-07-01

    Leaching of arsenic (As) from excavated rock subjected to different drying methods is compared using sequential leaching tests and rapid small-scale column tests combined with a sequential extraction procedure. Although the total As content in the rock was low (8.81 mg kg(-1)), its resulting concentration in the leachate when leached at a liquid-to-solid ratio of 10 L kg(-1) exceeded the environmental standard (10 μg L(-1)). As existed mainly in dissolved forms in the leachates. All of the drying procedures applied in this study increased the leaching of As, with freeze-drying leading to the largest increase. Water extraction of As using the two tests showed different leaching behaviors as a function of the liquid-to-solid ratio, and achieved average extractions of up to 35.7% and 25.8% total As, respectively. Dissolution of As from the mineral surfaces and subsequent re-adsorption controlled the short-term release of As; dissolution of Fe, Al, and dissolved organic carbon played important roles in long-term As leaching. Results of the sequential extraction procedure showed that use of 0.05 M (NH4)2SO4 underestimates the readily soluble As. Long-term water extraction removed almost all of the non-specifically sorbed As and most of the specifically sorbed As. The concept of pollution potential indices, which are easily determined by the sequential leaching test, is proposed in this study and is considered for possible use in assessing efficacy of treatment of excavated rocks. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Glass leaching performance

    International Nuclear Information System (INIS)

    Chick, L.A.; Turcotte, R.P.

    1983-05-01

    Current understanding of the leaching performance of high-level nuclear waste (HLW) glass is summarized. The empirical model of waste glass leaching behavior developed shows that at high water flow rates the glass leach rate is kinetically limited to a maximum value. At intermediate water flow rates, leaching is limited by the solution concentration of silica and decreases with decreasing water flow rates. Release of soluble elements is controlled by silica dissolution because silica forms the binding network of the glass. At low water flow rates, mass loss rates reach values controlled by formation rates of alteration minerals, or by diffusion of dissolution products through essentially stagnant water. The parameters reviewed with respect to their quantifiable influence on leaching behavior include temperature, pH, leachant composition, glass composition, thermal history, and radiation. Of these, temperature is most important since the rate of mass loss approximately doubles with each 10 0 C increase in dilute solutions. The pH has small effects within the 4 to 10 range. The chemical composition of the leachant is most important with regard to its influence on alteration product formation. Glass composition exhibits the largest effects at high flow rates where improved glasses leach from ten to thirty times slower than glass 76 to 68. The effects of the thermal history (devitrification) of the glass are not likely to be significant. Radiation effects are important primarily in that radiolysis can potentially drive pH values to less than 4. Radiation damage to the glass causes insignificant changes in leaching performance

  14. Leach rate studies on glass containing actual radioactive waste

    International Nuclear Information System (INIS)

    Walker, D.D.; Wiley, J.R.; Dukes, M.D.; LeRoy, J.H.

    1980-01-01

    Borosilicate glass containing radioactive wastes from the Savannah River Plant have been leached for 900 days. The International Standards Organization's (ISO) static leach test procedure was used on glass buttons in various leachants. Leach rates based on 90 Sr and 137 Cs analyses were similar: 2 x 10 -8 to 3 x 10 -8 g/(cm 2 )(d) in distilled water, 1 x 10 -8 to 3 x 10 -7 g/(cm 2 )(d) in pH 7 buffer, 3 x 10 -7 to 7 x 10 -7 g/(cm 2 )(d) in pH 9 buffer, and 7 x 10 -6 to 8 x 10 -5 g/(cm 2 )(d) in pH 4 buffer. Rates based on Pu analyses were the same as above in distilled water and pH 9 buffer, but were lower by an order of magnitude in pH 4 and pH 7 buffers. Almost all leach rates remained constant between 200 and 900 days of leaching. Increasing the concentration of the buffering agents had no effect on the leach rates at pH 7 (phosphate) and pH 9 (carbonate), but dramatically increased the rates at pH 4 (acetate). Leach rates did not differ significantly between high aluminum and high iron waste glasses

  15. Accelerated stress testing of thin film solar cells: Development of test methods and preliminary results

    Science.gov (United States)

    Lathrop, J. W.

    1985-01-01

    If thin film cells are to be considered a viable option for terrestrial power generation their reliability attributes will need to be explored and confidence in their stability obtained through accelerated testing. Development of a thin film accelerated test program will be more difficult than was the case for crystalline cells because of the monolithic construction nature of the cells. Specially constructed test samples will need to be fabricated, requiring committment to the concept of accelerated testing by the manufacturers. A new test schedule appropriate to thin film cells will need to be developed which will be different from that used in connection with crystalline cells. Preliminary work has been started to seek thin film schedule variations to two of the simplest tests: unbiased temperature and unbiased temperature humidity. Still to be examined are tests which involve the passage of current during temperature and/or humidity stress, either by biasing in the forward (or reverse) directions or by the application of light during stress. Investigation of these current (voltage) accelerated tests will involve development of methods of reliably contacting the thin conductive films during stress.

  16. Characterization, Leaching, and Filtration Testing for Bismuth Phosphate Sludge (Group 1) and Bismuth Phosphate Saltcake (Group 2) Actual Waste Sample Composites

    International Nuclear Information System (INIS)

    Lumetta, Gregg J.; Buck, Edgar C.; Daniel, Richard C.; Draper, Kathryn; Edwards, Matthew K.; Fiskum, Sandra K.; Hallen, Richard T.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Shimskey, Rick W.; Sinkov, Sergey I.; Snow, Lanee A.

    2009-01-01

    A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.() The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual waste-testing program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. Two of the eight defined groups - bismuth phosphate sludge (Group 1) and bismuth phosphate saltcake (Group 2) - are the subjects of this report. The Group 1 waste was anticipated to be high in phosphorus and was implicitly assumed to be present as BiPO4 (however, results presented here indicate that the phosphate in Group 1 is actually present as amorphous iron(III) phosphate). The Group 2 waste was also anticipated to be high in phosphorus, but because of the relatively low bismuth content and higher aluminum content, it was anticipated that the Group 2 waste would contain a mixture of gibbsite, sodium phosphate, and aluminum phosphate. Thus, the focus of the Group 1 testing was on determining the behavior of P removal during caustic leaching, and the focus of the Group 2 testing was on the removal of both P and Al. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467

  17. Leach behavior of hydrofracture grout incorporating radioactive wastes

    International Nuclear Information System (INIS)

    Moore, J.G.; Godbee, H.W.; Kibbey, A.H.

    1976-01-01

    Rates at which Sr, Cs, Pu, and Cm are leached from hydrofracture grout were measured. The fraction of an isotope leached varied with the square root of time if the leachant was replaced more frequently than once per day, but was inhibited or depressed if replacement was made less often. The amount of Sr or Cs leached from the grout varied directly with the degree of drying during curing and inversely with the time of curing. Of the clay additives studied for enhancing cesium retention, Grundite, while satisfactory, was the least effective. In general, the isotope leach rate followed the order: Cs greater than Sr greater than Cm greater than Pu. The amount leached as a function of the leachant varied in the order: distilled water greater than tap water greater than grout water. Concentrating the waste by a factor of up to 4 before grouting had little effect on the leach rate. Comparison with results for other products indicates that the grout can provide leach rates comparable to those for wastes incorporated into borosilicate glass. Theoretical relationships that consider diffusion and instantaneous reaction (an equilibrium or time-dependent relationship between mobile and immobile forms of a species) were in good agreement with the data for the 28-day-cured grout when the leachant was initially replaced twice per day. The credibility of laboratory results with simulated waste was substantiated by a short-term continuous leach test made on a fragment of a core sample of actual hydrofracture grout. The modified effective diffusivities (10 -11 to 10 -10 cm 2 /s, equivalent to a leach rate of the order of 10 -7 g cm -2 day -1 ) for Sr and Cs calculated from these data are comparable to laboratory values. 17 figures, 5 tables

  18. Vat leaching of gold ores and utilization of the tailings; Kinkoseki no vat leaching to koshi no yuko riyo

    Energy Technology Data Exchange (ETDEWEB)

    Hosooka, T. [Nippon Clay Mining Co. Ltd., Tokyo (Japan); Miyagawa, H. [Mitsui Mining and Smelting Co. Ltd., Tokyo (Japan)

    1996-01-25

    Mitsui Kushikino Mine previously processed two gold ores from Kushikino and Iwato ore deposits by the all slime cyanidation method, where the ores were ground to fine size smaller than 75 {mu}m and leached with sodium, cyanide. A large amount of slimes were produced as waste and discarded in tailings ponds. To save the costs of grinding and waste treatment it is desirable to process coarse sized ores. The Iwato ore is gold and silver bearing silicified porous rock. As most gold and silver in the Iwato ore are concentrated in the pores, leaching of coarse sized ore is expected to be possible. Laboratory tests and pilot plant tests of vat leaching for the Iwato ore were carried out using 0.15-8.0 mm feed. These results showed that the gold dissolution rate was similar to that by the all slime cyanidation and the decrease in gold recovery was a few %. The properties of these tailings can be used in fine aggregate of concrete. Based on the results vat leaching of the Iwato ore was adopted in the plant. The tailings are sold and used as fine aggregate. Utilization of slime tailings from the other ores was also developed and they are used as flux in copper smelters. Now, there is no tailings pond at Mitsui Kushikino Mine. 9 refs., 10 figs., 5 tabs.

  19. Operation of the Brookhaven national laboratory accelerator test facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; Van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program. (Author) 5 refs., 4 figs., tab

  20. Pollution potential leaching index as a tool to assess water leaching risk of arsenic in excavated urban soils.

    Science.gov (United States)

    Li, Jining; Kosugi, Tomoya; Riya, Shohei; Hashimoto, Yohey; Hou, Hong; Terada, Akihiko; Hosomi, Masaaki

    2018-01-01

    Leaching of hazardous trace elements from excavated urban soils during construction of cities has received considerable attention in recent years in Japan. A new concept, the pollution potential leaching index (PPLI), was applied to assess the risk of arsenic (As) leaching from excavated soils. Sequential leaching tests (SLT) with two liquid-to-solid (L/S) ratios (10 and 20Lkg -1 ) were conducted to determine the PPLI values, which represent the critical cumulative L/S ratios at which the average As concentrations in the cumulative leachates are reduced to critical values (10 or 5µgL -1 ). Two models (a logarithmic function model and an empirical two-site first-order leaching model) were compared to estimate the PPLI values. The fractionations of As before and after SLT were extracted according to a five-step sequential extraction procedure. Ten alkaline excavated soils were obtained from different construction projects in Japan. Although their total As contents were low (from 6.75 to 79.4mgkg -1 ), the As leaching was not negligible. Different L/S ratios at each step of the SLT had little influence on the cumulative As release or PPLI values. Experimentally determined PPLI values were in agreement with those from model estimations. A five-step SLT with an L/S of 10Lkg -1 at each step, combined with a logarithmic function fitting was suggested for the easy estimation of PPLI. Results of the sequential extraction procedure showed that large portions of more labile As fractions (non-specifically and specifically sorbed fractions) were removed during long-term leaching and so were small, but non-negligible, portions of strongly bound As fractions. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Static leaching of uraniferous shales with countercurrent circuits

    International Nuclear Information System (INIS)

    Cordero, G.; Villarrubia, M.; Hernandez, J.

    1973-01-01

    We test different amounts of acid and the way of adding it in order to obtain the solubilization of uranium in static leaching. We also test the effects of the temperature. Finally we show the tests of solvent extraction considering the most important variables in it . In leaching we must work with 32 kg/t of acid and 40 d in order to obtain uraniums solubilization over 80%, The pregnant liquors have a high concentration of silica and we must use low organic liquid ( ≤ 3,5 % in amine) and fit the acidity of the pregnant Solutions to 4-8 g H 2 SO 4 /I. We show the economy of the process. (Author)

  2. Evaluation of Accelerated Graphitic Corrosion Test of Gray Cast Iron

    International Nuclear Information System (INIS)

    Kim, Jeong Hyeon; Hong, Jong Dae; Chang Heui; Na, Kyung Hwan; Lee, Jae Gon

    2011-01-01

    In operating nuclear power plants, gray cast iron is commonly used as materials for various non-safety system components including pipes in fire water system, valve bodies, bonnets, and pump castings. In such locations, operating condition does not require alloy steels with excellent mechanical properties. But, a few corrosion related degradation, or graphitic corrosion is frequently occurred to gray cast iron during the long-term operation in nuclear power plant. Graphitic corrosion is selective leaching of iron from gray cast iron, where iron gets removed and graphite grains remain intact. In U.S.A., one-time visual inspection and hardness measurement are required from regulatory body to detect the graphitic corrosion for the life extension evaluation of the operating nuclear power plant. In this study, experiments were conducted to make accelerated graphitic corrosion of gray cast iron using electrochemical method, and hardness was measured for the specimens to establish the correlation between degree of graphitic corrosion and surface hardness of gray cast iron

  3. Leach-SX-EW copper revalorization from overburden of abandoned copper mine Cerovo, Eastern Serbia

    Directory of Open Access Journals (Sweden)

    Stevanović Z.

    2009-01-01

    Full Text Available Hydrometallurgical processes for copper revalorization from overburden of abandoned mine Cerovo in Eastern Serbia were studied. Paper contain results of percolation leaching tests, performed with acidic mine waters accumulated in the bottom of the former open pit, followed by solvent extraction (SX and electrowinning (EW processes on achieved copper pregnant leach solutions. Usage of accumulated waste waters was objected to minimizing the environmental hazard due to uncontrolled leaking of these waters in nearby creeks and rivers. Chemical composition of acidic mine waters used for leaching tests was: (g/dm3: Cu - 0.201; Fe - 0.095; Mn - 0.041; Zn - 0.026; Ni - 0.0004; pH value - 3.3. Copper content in overburden sample used for leaching tests was 0.21% from which 64% were oxide copper minerals. In scope of leaching tests were examined influence of leaching solution pH values and iron (III concentration on copper recovery. It was established that for 120 hours of leaching on pH=1.5 without oxidant agents, copper concentration in pregnant leach solutions enriched up to 1.08g/dm3 which was enough for copper extraction from solution with SX-EW treatment. As extraction reagent in SX circuit was used LIX-984N in a kerosene diluent. Cathode current density in electrowinning cell was 220Am-2 while electrolyte temperature was kept on 50±2oC. Produced cathode copper at the end of SX-EW process has purity of 99.95% Cu.

  4. Leaching behavior and chemical stability of copper butyl xanthate complex under acidic conditions.

    Science.gov (United States)

    Chang, Yi Kuo; Chang, Juu En; Chiang, Li Choung

    2003-08-01

    Although xanthate addition can be used for treating copper-containing wastewater, a better understanding of the leaching toxicity and the stability characteristics of the copper xanthate complexes formed is essential. This work was undertaken to evaluate the leaching behavior of copper xanthate complex precipitates by means of toxicity characteristics leaching procedure (TCLP) and semi-dynamic leaching test (SDLT) using 1 N acetic acid solution as the leachant. Also, the chemical stability of the copper xanthate complex during extraction has been examined with the studying of variation of chemical structure using UV-vis, Fourier transform infrared and X-ray photoelectron spectroscopies (XPS). Both TCLP and SDLT results showed that a negligible amount of copper ion was leached out from the copper xanthate complex precipitate, indicating that the complex exhibited a high degree of copper leaching stability under acidic conditions. Nevertheless, chemical structure of the copper xanthate complex precipitate varied during the leaching tests. XPS data suggested that the copper xanthate complex initially contained both cupric and cuprous xanthate, but the unstable cupric xanthate change to the cuprous form after acid extraction, indicating the cuprous xanthate to be the final stabilizing structure. Despite that, the changes of chemical structure did not induce the rapid leaching of copper from the copper xanthate complex.

  5. A 1MeV, 1A negative ion accelerator test facility

    International Nuclear Information System (INIS)

    Hanada, M.; Dairaku, M.; Inoue, T.; Miyamoto, K.; Ohara, Y.; Okumura, Y.; Watanabe, K.; Yokoyama, K.

    1995-01-01

    For the Proof-of-Principle test of negative ion acceleration up to 1 MeV, the beam energy required for ITER, a negative ion test facility named MeV Test Facility (MTF) and an ion source/accelerator have been designed and constructed. They are designed to produce a 1 MeV H- beam at a low source pressure of 0.13Pa. The MTF has a power supply system, which constituts of a 1MV, 1A, 60 s Cockcroft-Walton type dc high energy generator and power supplies for negative ion generation and extraction (ion source power supplies). The negative ion source/accelerator is composed of a cesiated volume source and a 5-stage, multi-aperture, electrostatic accelerator. The MTF and the ion source/accelerator have been completed, and the accelertion test up to 1 MeV of the H- ions has started. (orig.)

  6. A test accelerator for the next linear collider

    International Nuclear Information System (INIS)

    Ruth, R.D.; Adolphsen, C.; Bane, K.; Boyce, R.F.; Burke, D.L.; Callin, R.; Caryotakis, G.; Cassel, R.; Clark, S.L.; Deruyter, H.; Fant, K.; Fuller, R.; Heifets, S.; Hoag, H.; Humphrey, R.; Kheifets, S.; Koontz, R.; Lavine, T.; Loew, G.A.; Menegat, A.; Miller, R.H.; Paterson, J.M.; Pearson, C.; Phillips, R.; Rifkin, J.; Spencer, J.; Tantawi, S.; Thompson, K.A.; Vlieks, A.; Vylet, V.; Wang, J.W.; Wilson, P.B.; Yeremian, A.; Youngman, B.; Kroll, N.M.; Nantista, C.

    1993-07-01

    At SLAC, the authors are pursuing the design of a Next Linear Collider (NLC) which would begin with a center-of-mass energy of 0.5 TeV, and be upgradable to at least 1.0 TeV. To achieve this high energy, they have been working on the development of a high-gradient 11.4-GHz (X-band) linear accelerator for the main linac of the collider. In this paper, they present the design of a open-quotes Next Linear Collider Test Acceleratorclose quotes (NLCTA). The goal of the NLCTA is to incorporate the new technologies of X-band accelerator structures, RF pulse compression systems and klystrons into a short linac which will then be a test bed for beam dynamics issues related to high-gradient acceleration

  7. Leaching behaviour of tritium from a hardened cement paste

    International Nuclear Information System (INIS)

    Matsuzuru, H.; Moriyama, N.; Ito, A.

    1979-01-01

    Leaching of tritium from a hardened cement paste into an aqueous phase has been studied to assess the safety of solidification of the tritiated liquid waste with cement. Leaching tests were carried out in accordance with the method recommended by the International Atomic Energy Agency. The leaching fraction was measured as functions of the waste-cement wt ratio (Wa/C), temperature of leachant and curing time. the tritium leachability of cements follows the order: alumina cement > Portland cement > slag cement. The fraction of tritium leached increases with increasing Wa/C and temperature and decreasing curing period. A deionized water as a leachant gives a slightly higher leachability than the synthetic sea water. The coating of the specimen surface with bitumen reduces the leachability to about 5% of its value for the specimen without coating. (author)

  8. Leaching of nano-ZnO in municipal solid waste

    Energy Technology Data Exchange (ETDEWEB)

    Sakallioglu, T.; Bakirdoven, M.; Temizel, I. [Institute of Environmental Sciences, Bogazici University, 34342 Istanbul (Turkey); Demirel, B., E-mail: burak.demirel@boun.edu.tr [Institute of Environmental Sciences, Bogazici University, 34342 Istanbul (Turkey); Copty, N.K.; Onay, T.T.; Uyguner Demirel, C.S. [Institute of Environmental Sciences, Bogazici University, 34342 Istanbul (Turkey); Karanfil, T. [Environmental Engineering and Earth Science, Clemson University, Clemson, SC 29634 (United States)

    2016-11-05

    Highlights: • Leaching potential of 3 different types of nano-ZnO in real fresh MSW was investigated. • Batch tests were conducted at different pH, ionic strength and ZnO concentrations. • Most of the added nano-ZnO mass was retained within the solid waste matrix. • The pH and IS conditions did not significantly influence the leaching behavior of ZnO. • A kinetic particle deposition/detachment model was developed to analyze ZnO behavior. - Abstract: Despite widespread use of engineered nanomaterials (ENMs) in commercial products and their potential disposal in landfills, the fate of ENMs in solid waste environments are still not well understood. In this study, the leaching behavior of nano ZnO -one of the most used ENMs- in fresh municipal solid waste (MSW) was investigated. Batch reactors containing municipal solid waste samples were spiked with three different types of nano ZnO having different surface stabilization. The leaching of ZnO was examined under acidic, basic and elevated ionic strength (IS) conditions. The results of the 3-day batch tests showed that the percent of the added nano-ZnO mass retained within the solid waste matrix ranged between 80% and 93% on average for the three types of nano-ZnO tested. The pH and IS conditions did not significantly influence the leaching behavior of ZnO. To further analyze the behavior of ZnO in the MSW matrix, a kinetic particle deposition/detachment model was developed. The model was able to reproduce the main trends of the batch experiments. Reaction rate constants for the batch tests ranged from 0.01 to 0.4 1/hr, reflecting the rapid deposition of nano-ZnO within the MSW matrix.

  9. The current status of glass leaching studies in France

    International Nuclear Information System (INIS)

    Laude, F.

    1983-11-01

    Glass has been selected in France as the material used to confine the activity of fission product solutions, and a continuous vitrification process has been developed at the Marcoule Vitrification Facility (AVM), the first industrial plant. Borosilicate glass was chosen in various compositions for its properties: it is a homogeneous, non-porous material that incorporates appreciable quantities of most of the fission product oxides, and is only alterable at the surface interface layer. Glass thus constitutes the primary radioactivity containment barrier, and it is essential to determine its long-term behavior. Water constitutes the principal hazard during temporary or definitive storage of the glass blocks. Two types of inherent material properties are studied from the standpoint of glass stability under leaching conditions: - chemical durability; - radioactive containability with regard to the various radionuclides, fission products and especially the actinides. Durability tests are carried out in SOXHLET devices and the alteration rates are measured by the weight loss. The containability is measured by the leach rate, i.e. by the rate of activity loss into the water. Leaching tests are conducted for several major objectives: - selection of glass compositions (leach rates); - leaching mechanism studies (hydrolyzed layer characteristics, effects of temperature, pressure, pH, etc.); - long-term behavior studies (glass specimens doped with alpha-emitters); - simulation of geological repository environments [fr

  10. Simulation of pesticide leaching in a cracking clay soil with the PEARL model

    NARCIS (Netherlands)

    Scorza, R.P.; Boesten, J.J.T.I.

    2005-01-01

    Testing of pesticide leaching models is important to increase confidence in their use in pesticide registration procedures world-wide. The chromatographic PEARL model was tested against the results of a field leaching study on a cracking clay soil with a tracer (bromide), a mobile pesticide

  11. Influence of wood sample size and species on the leaching of chromium and copper using different lab tests

    OpenAIRE

    Bahmani, Mohsen; Schmidt, Olaf; Fromm, Jörg; Melcher, Eckhard

    2016-01-01

    The present study deals with the development of standardized laboratory methods to predict depletion of biocides more accurately under service condition. Laboratory test was conducted with EN 252 standard and non-standard pine as well as spruce specimens to determine leaching of chromium and copper from stakes pressure impregnated with commercial copper- and chromium-containing preservative. Two modified laboratory test methods were carried out; first discontinuous (CEN/TS 15119-1) and second...

  12. Investigations of metal leaching from mobile phone parts using TCLP and WET methods.

    Science.gov (United States)

    Yadav, Satyamanyu; Yadav, Sudesh

    2014-11-01

    Metal leaching from landfills containing end-of-life or otherwise discarded mobile phones poses a threat to the environment as well as public health. In the present study, the metal toxicity of printed wire boards (PWBs), plastics, liquid crystal displays (LCDs) and batteries of mobile phones was assessed using the Toxicity Characteristics Leaching Procedures (TCLP) and the Waste Extraction Test (WET). The PWBs failed TCLP for Pb and Se, and WET for Pb and Zn. In WET, the two PWB samples for Pb and Zn and the battery samples for Co and Cu failed the test. Furthermore, the PWBS for Ni and the battery samples for Ni and Co failed the WET in their TCLP leachates. Both, Ni and Co are the regulatory metals in only WET and not covered under TCLP. These observations indicate that the TCLP seems to be a more aggressive test than the WET for the metal leaching from the mobile phone parts. The compositional variations, nature of leaching solution (acetate in TCLP and citrate in WET) and the redox conditions in the leaching solution of the PWBs resulted in different order of metals with respect to their amounts of leaching from PWBs in TCLP (Fe > Pb > Zn > Ni > Co > Cu) and WET (Zn > Fe > Ni > Pb > Cu). The metal leaching also varied with the make, manufacturing year and part of the mobile phone tested. PWBs, plastics and batteries should be treated as hazardous waste. Metal leaching, particularly of Se and Pb, from mobile phones can be harmful to the environment and human health. Therefore, a scientifically sound and environmentally safe handling and disposal management system needs to be evolved for the mobile phone disposal. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Leaching of heavy metals from steelmaking slags

    Directory of Open Access Journals (Sweden)

    Gomes, J. F. P

    2006-12-01

    Full Text Available Leaching tests with EAF and Ladle slags were performed, using a flow through test and the standard batch test DIN 38414-S4. The previous method was used to simulate the leaching behaviour of steel slags under landfill. The chemical analysis of the leachates during this period shows, in general, for both types of slag, an increase of heavy metal releases with ageing. Standard test method DIN 38414-S4 was used to evaluate leachability of heavy metals by water in unprocessed slags. After more than one year of trials, slag samples submitted to these trials presented very low total leaching levels. The most extracted elements are calcium and magnesium. Nevertheless, in flow-through test, calcium and magnesium leached from solid slags are below 0.5% and all other metals below 0.1%. Leachates obtained with DIN 38414-S4 present, as expected, higher leaching values; however, these are inferior to 5 % (Ca and 1% (other elements.

    Este articulo contiene los resultados obtenidos en ensayos de lixiviación de escorias de acero (horno electrico y cuchara ejecutados siguiendo la metodologia de flujo dinámico así como el ensayo normalizado DIN 38414-S4. El primer ensayo intenta simular el comportamiento de lixiviación de las escorias en vertedero. Para las escorias ensayadas se han complementado los ensayos con el análisis químico de los lixiviados y se ha verificado un aumento de la liberación de metales pesados. El ensayo DIN 38414-S4 se ha utilizado para evaluar la lixiviación por agua de metales pesados, en muestras de escorias originales. Despues de un año de ensayos, se han observado niveles muy bajos de lixiviación. Los elementos mas lixiviados han sido calcio y magnesio. No obstante, en los ensayos de flujo dinámico, el calcio y el magnesio lixiviados de las escorias sólidas era menor de 0,5% y el resto de los otros metales era inferior a 0,1%. Los lixiviados obtenidos con el ensayo DIN 38414-S4 presentan, como era de esperar, valores

  14. Status and Plans for a Superconducting RF Accelerator Test Facility at Fermilab

    International Nuclear Information System (INIS)

    Andrews, R.; Baffes, C.M.; Carlson, K.; Chase, B.; Church, M.D.; Harms, E.R.; Klebaner, A.L.; Leibfritz, J.R.; Martinez, A.; Nagaitsev, S.; Nobrega, L.E.

    2012-01-01

    The Advanced Superconducting Test Accelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating a 750 MeV electron beam with ILC beam intensity. An expansion of this facility was recently completed that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. Two new buildings were also constructed adjacent to the ASTA facility to house a new cryogenic plant and multiple superconducting RF (SRF) cryomodule test stands. In addition to testing accelerator components, this facility will be used to test RF power systems, instrumentation, and control systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

  15. Influence of the leaching mode on the durability of a glass for fission product containment

    International Nuclear Information System (INIS)

    Nogues, J.L.; Terki, A.

    1984-06-01

    The chemical durability of a glass containing wastes from light water reactor (LWR) has been studied with three different lixiviation modes: ''static'' leach test, ''soxhlet'' test and ''continuous flow'' test. After a description of these tests, the leaching mode influence on the glass durability is reported as obtained from weight loss measurements, analyses of the leaching solutions and surface analyses of the samples. Finally, the corrosion mechanisms of this type of glass are approached and a phenomenological explanation of attack from an aqueous solution is proposed [fr

  16. Residues leaching from 'Factory of barren ores'

    International Nuclear Information System (INIS)

    Rakhmatov, N.; Khakimov, N.; Nazarov, Kh.M.; Barotov, A.M.

    2012-01-01

    The objective of the present work is safe management of residues from Factory of Barren Ores, their reprocessing, expenditures reduction for remediation of Istiklol city former uranium tailings. For this purpose, some experiences were adopted - Factory of Barren Ores tailing use for filling up the open pit where water with uranium content 3-5 mg/l is located. Factory of Barren Ores waste are passed through heap leaching and have some amount of uranium salts dissolved in water. Thus, we propose to dissolve uranium from Factory of Barren Ores wastes with uranium bearing water flowing out from gallery and filling up the open-pit by radioactive wastes. In so doing, uranium content flowing out from gallery will increase twice, and further, passing them through apricot's shell, as a sorbent, we will clean the water against radionuclides. Residue samples with uranium content 0,015% from Factory of Barren Ores and uranium bearing waters from gallery 1 with uranium content 0,0025 g/l were used for laboratory tests. After which, a slurry was prepared by means of residue mixing with water in ratio of solid and liquid phases (S:L) - 1:2 and 9,7 ml of sulfuric acid (Ρ=1,82) was added which corresponds consumption by H 2 SO 4 176,54 kg/t. For the first test, leaching was carried out during 4 hours at ph=1,6 at room temperature. For the second test, leaching was carried out at 60 d eg C a nd ph=1,6 during 4 hours. Slurry heating and mixing was carried out by means of magnetic mixer. The basic residue leaching indicators are provided in this article.

  17. Study of controlled leaching process of steel slag in Soxhlet extractor aiming employment in pavements

    International Nuclear Information System (INIS)

    Costa, Kissyla Avila; Guimaraes, Antonio Carlos Rodrigues; Reis, Marcelo de Miranda; Santana, Claudeny Simone Alves

    2017-01-01

    This work addresses the characterization of physical, chemical and mechanical properties of steel slag as an alternative aggregation before and after leaching testing controlled Soxhlet extractor. The material it was characterized before going through the natural leaching process and after controlled leaching in different periods of 24, 56, 96, 120 hours. The steel slag was subjected in the laboratory to simulate the precipitation in Soxhlet equipment to evaluate its physical, chemical and mechanical properties after each period described. The study of the process of leaching in steel slag searched to understand the influence of the washing process in a slag behavior in such a process. The physical characterization occurred through traditional testing of coarse aggregates, the chemical characterization through the testing of Scanning Electron Microscopy (SEM) completed by Dispersive Spectroscopy Energy (DSE) and X- ray diffraction and the mechanical characterization through testing of standardized expansion and adapted. The sample virgin, without receiving process of stabilization by controlled leaching, showed satisfactory results in the physics characterization when compared to conventional aggregates, the chemical characterization proved to be a steel slag with high contents of CaO, MgO and FeO, the mechanical characterization demonstrated that, although the degree of expansibility of the slag is low demonstrated that this should not be disregarded in the paving work. After controlled leaching the steel slag showed no significant loss of its physical properties. As the mechanical testing of expansion had decreased the potential of expansibility after leaching periods. It is concluded that the leaching process in a Soxhlet extractor is of importance in the study the properties of steel slag, once covering several days of leaching was reduced potential for expansion, limiting feature in the use of steel slag for paving. (author)

  18. Alkaline leaching of coal by the mechanochemical treatment

    Directory of Open Access Journals (Sweden)

    Turèániová ¼udmila

    1998-09-01

    Full Text Available The possibility of application of a new process GACL (Grinding and Aqueous Caustic Leaching for the reduction of mineral components in the brown coal Nováky was tested. The simultaneous grinding and chemical leaching enable us to extract 41 % total sulphur, 95 % arsenic and to reduce the ash content to 43 %. The process proceeds at the atmospheric pressure, temperature 90oC and in diluted NaOH solutions (5 %.

  19. Leaching behavior of glass ceramic nuclear waste forms

    International Nuclear Information System (INIS)

    Lokken, R.O.

    1981-11-01

    Glass ceramic waste forms have been investigated as alternatives to borosilicate glasses for the immobilization of high-level radioactive waste at Pacific Northwest Laboratory (PNL). Three glass ceramic systems were investigated, including basalt, celsian, and fresnoite, each containing 20 wt % simulated high-level waste calcine. Static leach tests were performed on seven glass ceramic materials and one parent glass (before recrystallization). Samples were leached at 90 0 C for 3 to 28 days in deionized water and silicate water. The results, expressed in normalized elemental mass loss, (g/m 2 ), show comparable releases from celsian and fresnoite glass ceramics. Basalt glass ceramics demonstrated the lowest normalized elemental losses with a nominal release less than 2 g/m 2 when leached in polypropylene containers. The releases from basalt glass ceramics when leached in silicate water were nearly identical with those in deionized water. The overall leachability of celsian and fresnoite glass ceramics was improved when silicate water was used as the leachant

  20. The electron test accelerator safety in design and operation

    International Nuclear Information System (INIS)

    McKeown, J.

    1980-06-01

    The Electron Test Accelerator is being designed as an experiment in accelerator physics and technology. With an electron beam power of up to 200 kW the operation of the accelerator presents a severe radiation hazard as well as rf and electrical hazards. The design of the safety system provides fail-safe protection while permitting flexibility in the mode of operation and minimizing administrative controls. (auth)

  1. Leaching characteristics of the metal waste form from the electrometallurgical treatment process: Product consistency testing

    International Nuclear Information System (INIS)

    Johnson, S. G.; Keiser, D. D.; Frank, S. M.; DiSanto, T.; Noy, M.

    1999-01-01

    Argonne National Laboratory is developing an electrometallurgical treatment for spent fuel from the experimental breeder reactor II. A product of this treatment process is a metal waste form that incorporates the stainless steel cladding hulls, zirconium from the fuel and the fission products that are noble to the process, i.e., Tc, Ru, Nb, Pd, Rh, Ag. The nominal composition of this waste form is stainless steel/15 wt% zirconium/1--4 wt% noble metal fission products/1--2 wt % U. Leaching results are presented from several tests and sample types: (1) 2 week monolithic immersion tests on actual metal waste forms produced from irradiated cladding hulls, (2) long term (>2 years) pulsed flow tests on samples containing technetium and uranium and (3) crushed sample immersion tests on cold simulated metal waste form samples. The test results will be compared and their relevance for waste form product consistency testing discussed

  2. Solid State Characterizations of Long-Term Leached Cast Stone Monoliths

    Energy Technology Data Exchange (ETDEWEB)

    Asmussen, Robert M.; Pearce, Carolyn I.; Parker, Kent E.; Miller, Brian W.; Lee, Brady D.; Buck, Edgar C.; Washton, Nancy M.; Bowden, Mark E.; Lawter, Amanda R.; McElroy, Erin M.; Serne, R Jeffrey

    2016-09-30

    This report describes the results from the solid phase characterization of six Cast Stone monoliths from the extended leach tests recently reported on (Serne et al. 2016),that were selected for characterization using multiple state-of-the-art approaches. The Cast Stone samples investigated were leached for > 590 d in the EPA Method 1315 test then archived for > 390 d in their final leachate. After reporting the long term leach behavior of the monoliths (containing radioactive 99Tc and stable 127I spikes and for original Westsik et al. 2013 fabricated monoliths, 238U), it was suggested that physical changes to the waste forms and a depleting inventory of contaminants of potential concern may mean that effective diffusivity calculations past 63 d should not be used to accurately represent long-term waste form behavior. These novel investigations, in both length of leaching time and application of solid state techniques, provide an initial arsenal of techniques which can be utilized to perform such Cast Stone solid phase characterization work, which in turn can support upcoming performance assessment maintenance. The work was performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to characterize several properties of the long- term leached Cast Stone monolith samples.

  3. An accelerated test method for efflorescence in clay bricks

    International Nuclear Information System (INIS)

    Beggan, John Edward

    1998-01-01

    An investigation into the creation of accelerated efflorescence in clay bricks was undertaken with a view to creating a viable test procedure for determining efflorescence potential. The testing programme incorporated ambient conditions similar to those which promote efflorescence growth in bricks in use. Theoretical investigations into the physical mechanism underlying the creation of efflorescence directed the attempts to accelerate the process. It was found that calcium sulphate efflorescence could not be sufficiently accelerated such that a useful efflorescence test procedure could be proposed. The inability to produce accelerated efflorescence in brick samples was attributed to limitations associated with time dependent salt diffusion in the efflorescence mechanism. The preliminary testing that was undertaken into the creation of efflorescence prompted the use of acid assisted methods to accelerate efflorescence. The acid assisted method that was adopted to provide a possible indication of efflorescence potential relies upon the transformation of low solubility calcium to a more soluble form. The movement of the transformed salt is then induced by cyclic temperature exposure at temperatures similar to those experienced in Spring. The appearance of the transformed calcium salt on the surface of the brick specimen provides an indication of the efflorescence potential. Brick piers constructed on an exposed site and monitored over a 12 month period provided information on the validity of the acid assisted test method. The efflorescence observed on the piers correlated well with that predicted by the acid assisted test, suggesting that the new test has the potential to accurately predict the efflorescence potential of clay bricks Relationships between other properties such as air permeability, sorptivity and tensile strength were investigated such that an alternative method of predicting efflorescence could be achieved. It was found that (within the bounds of the

  4. Reduction of metal leaching in brown coal fly ash using geopolymers

    International Nuclear Information System (INIS)

    Bankowski, P.; Zou, L.; Hodges, R.

    2004-01-01

    Current regulations classify fly ash as a prescribed waste and prohibit its disposal in regular landfill. Treatment of the fly ash can reduce the leach rate of metals, and allow it to be disposed in less prescribed landfill. A geopolymer matrix was investigated as a potential stabilisation method for brown coal fly ash. Precipitator fly ash was obtained from electrostatic precipitators and leached fly ash was collected from ash disposal ponds, and leaching tests were conducted on both types of geopolymer stabilised fly ashes. The ratio of fly ash to geopolymer was varied to determine the effects of different compositions on leaching rates. Fourteen metals and heavy metals were targeted during the leaching tests and the results indicate that a geopolymer is effective at reducing the leach rates of many metals from the fly ash, such as calcium, arsenic, selenium, strontium and barium. The major element leachate concentrations obtained from leached fly ash were in general lower than that of precipitator fly ash. Conversely, heavy metal leachate concentrations were lower in precipitator fly ash than leached pond fly ash. The maximum addition of fly ash to this geopolymer was found to be 60 wt% for fly ash obtained from the electrostatic precipitators and 70 wt% for fly ash obtained from ash disposal ponds. The formation of geopolymer in the presence of fly ash was studied using 29Si MAS-NMR and showed that a geopolymer matrix was formed. X-ray diffraction (XRD) analysis and scanning electron microscopy (SEM) imaging showed the interaction of the fly ash with the geopolymer, which was related to the leachate data and also the maximum percentage fly ash addition

  5. Leaching of metals from soil contaminated by mining activities.

    Science.gov (United States)

    Yukselen, M A; Alpaslan, B

    2001-10-12

    Stabilization/solidification (s/s) is one of the most effective methods of dealing with heavy metal contaminated sites. The ability of lime and cement stabilization to immobilize Pb, Cu and Fe contained in a contaminated soil originating from an old mining and smelting area located along the Mediterranean Sea shore in northern Cyprus was investigated. The stabilization was evaluated by applying leaching tests. A series of tests were conducted to optimize the additive soil ratio for the best immobilization process. Additive/soil=1/15 (m/m) ratio was found to be the optimum for both lime and cement. Application of the US EPA toxicity characteristic leaching procedure (TCLP) on the soil samples treated with lime at additive/soil=1/15 (m/m) mixing ratios showed that Cu and Fe solubility was reduced at 94 and 90%, respectively. The results of cement treatment using the same ratio, reduced the solubility 48 and 71% for Cu and Fe, respectively. The Pb solubility was found to be below the regulatory limit of 5mg/l so no additive treatment was needed. The optimum additive/soil amount (1/15) was selected for more detailed column studies, that were carried out in the acidic pH range. According to the results of column leaching tests, it was found that, the degree of heavy metal leaching is highly dependent on pH.

  6. Long-time leaching on full size radioactive waste blocks

    International Nuclear Information System (INIS)

    Bernard, Andre; Nomine, J.-C.; Cornec, Georges; Bonnet, Andre; Farges, Louis.

    1980-12-01

    Leaching is generally accepted as the fundamental characteristic when judging the quality of radioactive waste packaging. Long duration leaching tests have been carried out on full size waste blocks at the Commissariat a l'Energie Atomique. The monoliths studied are 200 litre cylinders made up of α, β and γ emitting liquid or solid waste embedded in cement or bitumen. Leaching takes place in accordance with rules based on I.A.E.A. recommendations embodying the specific concerns of safety and radiological capacity of storage sites. The tests are carried out at a Testing Station purpose built at Saclay. It includes several loops with instrumentation (volume: 3000 litres). The counting and analyses of the leached products have enabled the aggregated released fractions of the radionuclides and the structural and chemical modifications of the matrices to be assessed. The fractions of 137 Cs and 239 Pu released at 18 months are 10 -2 and 5x10 -6 for the cement coated wastes, and 10 -4 and 10 -5 for the bitumen coated wastes. The evaluation of the changes in the matrices made it possible, in particular, to observe the start of carbonation in the cement coated wastes. These trials are to be pursued for several years so as to obtain a better understanding of the exchange mechanics between the packaged wastes and the environment [fr

  7. A case study of shrinkage-in place leaching of low grade uranium ore deposit

    International Nuclear Information System (INIS)

    Ding Dexin; Zhou Guohe

    1998-09-01

    A case study of shrinkage-in place leaching of low grade uranium ore deposit is dealt with. A test block was selected, and the shrinkage mining method was employed to construct the in place heap for leaching. Blast parameters and operations were carefully tried in order to make sure that the fragment size composition was adequate for leaching. A leaching system was planned and the corresponding leaching parameters were tried, too. The results show that the shrinkage method and the parameters for blasting and leaching are all adequate for the in-situ leaching of the blasted ore. This shrinkage-in place leaching system combines the mining and metallurgy processes into one and produces a lot of profits and could be applicable to many low grade uranium ore deposits which are so hard and compact that they have to be fragmented before being leached

  8. Nuclear-waste-package materials degradation modes and accelerated testing

    International Nuclear Information System (INIS)

    1981-09-01

    This report reviews the materials degradation modes that may affect the long-term behavior of waste packages for the containment of nuclear waste. It recommends an approach to accelerated testing that can lead to the qualification of waste package materials in specific repository environments in times that are short relative to the time period over which the waste package is expected to provide containment. This report is not a testing plan but rather discusses the direction for research that might be considered in developing plans for accelerated testing of waste package materials and waste forms

  9. Bacterial leaching of waste uranium materials.

    Science.gov (United States)

    Barbic, F F; Bracilović, D M; Krajincanić, B V; Lucić, J L

    1976-01-01

    The effect of ferrobacteria and thiobacteria on the leaching of waste uranium materials from which 70-80% of uranium was previously leached by classical chemical hydrometallurgical procedure has been investigated. The bacteria used are found in the ore and the mine water of Zletovska River locality, Yugoslavia. Parameters of biological leaching were examined in the laboratory. Leaching conditions were changed with the aim of increasing the amount of uranium leached. The effect of pyrite added to the waste materials before the beginning of leaching has also been examined. Uranium leaching is directly proportional to the composition and number of ferrobacteria and thiobacteria, and increased by almost twice the value obtained from the same starting materials without using bacteria. Increased sulphuric acid concentrations stimulate considerably the rate of leaching. Uranium leaching is increased up to 20% while sulphuric acid consumption is simultaneously decreased by the addition of pyrite. Uranium concentrations in starting waste materials used for leaching were extremely low (0.0278 and 0.372% U) but about 60% recovery of uranium was obtained, with relatively low consumption of sulphuric acid.

  10. Bacterial leaching of waste uranium materials

    International Nuclear Information System (INIS)

    Barbic, F.F.; Bracilovic, D.M.; Krajincanic, B.V.; Lucic, J.L.

    1976-01-01

    The effect of ferrobacteria and thiobacteria on the leaching of waste uranium materials from which 70-80% of uranium was previously leached by classical chemical hydrometallurgical procedure has been investigated. The bacteria used are found in the ore and the mine water of Zletovska River locality, Yugoslavia. Parameters of biological leaching were examined in the laboratory. Leaching conditions were changed with the aim of increasing the amount of uranium leached. The effect of pyrite added to the waste materials before the beginning of leaching has also been examined. Uranium leaching is directly proportional to the composition and number of ferrobacteria and thiobacteria, and increased by almost twice the value obtained from the same starting materials without using bacteria. Increased sulphuric acid concentrations stimulate considerably the rate of leaching. Uranium leaching is increased up to 20% while sulphuric acid consumption is simultaneously decreased by the addition of pyrite. Uranium concentrations in starting waste materials used for leaching were extremely low (0.0278 and 0.0372% U) but about 60% recovery of uranium was obtained, with relatively low consumption of sulphuric acid. (author)

  11. Basic and Acidic Leaching of Sludge from Melton Valley Storage Tank W-25

    Energy Technology Data Exchange (ETDEWEB)

    Collins, J.L., Egan, B.Z., Beahm, E.C., Chase, C.W., Anderson, K.K.

    1997-10-01

    Bench-scale leaching tests were conducted with samples of tank waste sludge from the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to evaluate separation technology processes for use in concentrating the radionuclides and reducing the volume of waste for final disposal. This paper discusses the hot cell apparatus, the characterization of the sludge, the leaching methodology, and the results obtained from a variety of basic and acidic leaching tests of samples of sludge at ambient temperature. Basic leaching tests were also conducted at 75 and 95 deg C. The major alpha-,gamma., and beta-emitting radionuclides in the centrifuged, wet sludge solids were {sup 137}Cs, {sup 60}Co, {sup 154}Eu, {sup 241}Am, {sup 244}Cm {sup 90}Sr, Pu, U, and Th. The other major metals (in addition to the U and Th) and anions were Na, Ca, Al, K, Mg, NO{sub 3}{sup -},CO{sub 3}{sup 2-}, OH{sup -}, and O{sup 2-} organic carbon content was 3.0 +/- 1.0%. The pH was 13. A surprising result was that about 93% of the {sup 137}Cs in the centrifuged, wet sludge solids was bound in the solids and could not be solubilized by basic leaching at ambient temperature and 75 deg C. However, the solubility of the {sup 137}Cs was enhanced by heating the sludge to 95 deg C. In one of the tests,about 42% of the {sup 137}Cs was removed by leaching with 6.3 M NaOH at 95 deg C.Removing {sup 137}Cs from the W-25 sludge with nitric acid was a slow process. About 13% of the {sup 137}Cs was removed in 16 h with 3.0 M HNO{sub 3}. Only 22% of the {sup 137}Cs was removed in 117 h usi 6.0 M HNO{sub 3}. Successive leaching of sludge solids with 0.5 M, 3.0 M, 3.0 M; and 6.0 M HNO{sub 3} for a total mixing time of 558 h removed 84% of the {sup 137}Cs. The use of caustic leaching prior to HNO{sub 3} leaching, and the use of HF with HNO{sub 3} in acidic leaching, increased the rate of {sup 137}Cs dissolution. Gel formation proved to be one of the biggest problems associated with HNO{sub 3

  12. Basic and Acidic Leaching of Sludge from Melton Valley Storage Tank W-25

    International Nuclear Information System (INIS)

    Collins, J.L.; Egan, B.Z.; Beahm, E.C.; Chase, C.W.; Anderson, K.K.

    1997-10-01

    Bench-scale leaching tests were conducted with samples of tank waste sludge from the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to evaluate separation technology processes for use in concentrating the radionuclides and reducing the volume of waste for final disposal. This paper discusses the hot cell apparatus, the characterization of the sludge, the leaching methodology, and the results obtained from a variety of basic and acidic leaching tests of samples of sludge at ambient temperature. Basic leaching tests were also conducted at 75 and 95 deg C. The major alpha-,gamma., and beta-emitting radionuclides in the centrifuged, wet sludge solids were 137 Cs, 60 Co, 154 Eu, 241 Am, 244 Cm 90 Sr, Pu, U, and Th. The other major metals (in addition to the U and Th) and anions were Na, Ca, Al, K, Mg, NO 3 - ,CO 3 2- , OH - , and O 2- organic carbon content was 3.0 +/- 1.0%. The pH was 13. A surprising result was that about 93% of the 137 Cs in the centrifuged, wet sludge solids was bound in the solids and could not be solubilized by basic leaching at ambient temperature and 75 deg C. However, the solubility of the 137 Cs was enhanced by heating the sludge to 95 deg C. In one of the tests,about 42% of the 137 Cs was removed by leaching with 6.3 M NaOH at 95 deg C.Removing 137 Cs from the W-25 sludge with nitric acid was a slow process. About 13% of the 137 Cs was removed in 16 h with 3.0 M HNO 3 . Only 22% of the 137 Cs was removed in 117 h usi 6.0 M HNO 3 . Successive leaching of sludge solids with 0.5 M, 3.0 M, 3.0 M; and 6.0 M HNO 3 for a total mixing time of 558 h removed 84% of the 137 Cs. The use of caustic leaching prior to HNO 3 leaching, and the use of HF with HNO 3 in acidic leaching, increased the rate of 137 Cs dissolution. Gel formation proved to be one of the biggest problems associated with HNO 3 leaching of the W-25 sludge

  13. Accelerated Test Method for Corrosion Protective Coatings

    Data.gov (United States)

    National Aeronautics and Space Administration — This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as...

  14. Leaching characteristics of polybrominated diphenyl ethers (PBDEs) from flame-retardant plastics.

    Science.gov (United States)

    Kim, Yong-Jin; Osako, Masahiro; Sakai, Shin-ichi

    2006-10-01

    To investigate the effect of leachant on the leachability of polybrominated diphenyl ethers (PBDEs), we determined the leaching concentrations of PBDEs from flame-retardant plastic samples (TV housings and raw materials before molding processing) that are regarded as a source of PBDEs in landfill sites. The leachants used were distilled water, 20% methanol solution, and dissolved humic solution (DHS) of 1000 mg/l based on organic carbon. The leaching test conditions were a liquid-to-solid ratio of 100:1, and a contact period of five days, with twice-daily agitation in a temperature-controlled room of 30 degrees C without pH or ionic strength control. The leaching concentrations of PBDEs increased with increased content, and were found to be remarkably enhanced when methanol and DHS were used instead of distilled water. The enhancement of leachability in the presence of the latter was attributed to the cosolvency effect, and complex formations between the PBDEs and dissolved humic matter (DHM). PBDE concentrations in the leachate obtained from the leaching test and an actual landfill site revealed a significant presence of congeners below heptabromodiphenyl ethers (H7BDEs), detected in the leachate of the actual landfill, while significant amounts of nonabromodiphenyl ethers (N9BDEs) and decabromodiphenyl ether (D10BDE) were detected in the leachate of the leaching test.

  15. In situ leaching of uranium

    International Nuclear Information System (INIS)

    Martin, B.

    1980-01-01

    A process is described for the in-situ leaching of uranium-containing ores employing an acidic leach liquor containing peroxymonosulphuric acid. Preferably, additionally, sulphuric acid is present in the leach liquor. (author)

  16. Accelerated pavement testing of low-volume paved roads with geocell reinforcement.

    Science.gov (United States)

    2015-03-01

    The Midwest States Accelerated Pavement Testing Pooled-Fund Program, financed by the highway : departments of Kansas, Iowa, Missouri, and New York, has supported an accelerated pavement testing (APT) project : to study the rehabilitation of low-volum...

  17. Technical application of agglomerated acidic heap leaching of clay-bearing uranium ore in China

    International Nuclear Information System (INIS)

    Zeng Yijun; Li Jianhua; Li Tieqiu; Zhong Pingru

    2002-01-01

    The permeability of ore mass has a great influence on the leaching period of heap leaching and the leaching efficiency, hence the uranium ores with high content of clay is difficult to acidic heap leaching. The Research Institute of Uranium Mining has engaged several years studies on the cementing agents of acidic agglomeration, agglomeration conditions, as well as the curing measures of agglomerated balls. On the basis of these studies, several types of clay-bearing ores have been tested with good results. The technique of agglomerated acidic heap leaching has been successfully applied in a uranium mine. Since agglomeration has effectively increased the permeability of ore heap, its leaching period is decreased from 200 days to 60 days, the leaching efficiency is increased to 96% from less than 40% comparing with direct heap leaching program

  18. Caustic leaching of composite AZ-101/AZ-102 Hanford tank sludge

    International Nuclear Information System (INIS)

    Rapko, B.M.; Wagner, M.J.

    1997-07-01

    To reduce the quantity (and hence the cost) of glass canisters needed for disposing of high-level radioactive wastes from the Hanford tank farms, pretreatment processes are needed to remove as much nonradioactive material as possible. This report describes the results of a laboratory-scale caustic leaching test performed on a composite derived from a combination of 241-AZ-101 and 241-AZ-102 Hanford Tank sludges. The goals of this FY 1996 test were to evaluate the effectiveness of caustic leaching on removing key components from the sludge and to evaluate the effectiveness of varying the free-hydroxide concentrations by incrementally increasing the free hydroxide concentration of the leach steps up to 3 M free hydroxide. Particle-size analysis of the treated and untreated sludge indicated that the size and range of the sludge particles remained essentially unchanged by the caustic leaching treatment. Both before and after caustic leaching, a particle range of 0.2 microm to 50 microm was observed, with mean particle diameters of 8.5 to 9 microm based on the volume distribution and mean particle diameters of 0.3 to 0.4 microm based on the number distribution

  19. Testing of a Plasmadynamic Hypervelocity Dust Accelerator

    Science.gov (United States)

    Ticos, Catalin M.; Wang, Zhehui; Dorf, Leonid A.; Wurden, G. A.

    2006-10-01

    A plasmadynamic accelerator for microparticles (or dust grains) has been designed, built and tested at Los Alamos National laboratory. The dust grains are expected to be accelerated to hypervelocities on the order of 1-30 km/s, depending on their size. The key components of the plasmadynamic accelerator are a coaxial plasma gun operated at 10 kV, a dust dispenser activated by a piezoelectric transducer, and power and remote-control systems. The coaxial plasma gun produces a high density (10^18 cm-3) and low temperature (˜ 1 eV) plasma in deuterium ejected by J x B forces, which provides drag on the dust particles in its path. Carbon dust particles will be used, with diameters from 1 to 50 μm. The plasma parameters produced in the coaxial gun are presented and their implication to dust acceleration is discussed. High speed dust will be injected in the National Spherical Torus Experiment to measure the pitch angle of magnetic field lines.

  20. Study of the sulfuric acid leaching and bacterial leaching of low grade uranium ore by orbital shaker experiment

    International Nuclear Information System (INIS)

    Li Guangyue; Liu Yulong; Wang Yongdong; Ding Dexin

    2009-01-01

    The sulphuric acid leaching and bacteria leaching by orbital shaker experiments were conducted for the low grade uranium ore from a uranium mine in Guangdong Province. The results show that, when the concentration of sulphuric acid and that of slurry were 30 g/L and 25%, respectively, the conditions were most favourable for sulphuric acid leaching and the rate of leaching reached 92.92%, that, when pH value was 1.5, inoculation amount, 10%, concentration of slurry, 10%, the conditions were most favourable for bacteria leaching and the rate of leaching reached 95.93%, that, compared with sulphuric acid leaching, bacteria leaching decreased sulphuric acid consumption by 17.2% and increased the rate of leaching by 3%, and that, under the most favourable conditions for suphuric acid leaching, if 1% natrium chlorate was added, the rate of leaching increased to 96.46%, but 10 kg of natrium chlorate was consumed for 1 ton of uranium ore. (authors)

  1. Manufacturing and Testing of Accelerator Superconducting Magnets

    CERN Document Server

    Rossi, L

    2014-01-01

    Manufacturing of superconducting magnet for accelerators is a quite complex process that is not yet fully industrialized. In this paper, after a short history of the evolution of the magnet design and construction, we review the main characteristics of the accelerator magnets having an impact on the construction technology. We put in evidence how the design and component quality impact on construction and why the final product calls for a total-quality approach. LHC experience is widely discussed and main lessons are spelled out. Then the new Nb$_{3}$Sn technology, under development for the next generation magnet construction, is outlined. Finally, we briefly review the testing procedure of accelerator superconducting magnets, underlining the close connection with the design validation and with the manufacturing process.

  2. Manufacturing and Testing of Accelerator Superconducting Magnets

    International Nuclear Information System (INIS)

    Rossi, L

    2014-01-01

    Manufacturing of superconducting magnet for accelerators is a quite complex process that is not yet fully industrialized. In this paper, after a short history of the evolution of the magnet design and construction, we review the main characteristics of the accelerator magnets having an impact on the construction technology. We put in evidence how the design and component quality impact on construction and why the final product calls for a total-quality approach. LHC experience is widely discussed and main lessons are spelled out. Then the new Nb3Sn technology, under development for the next generation magnet construction, is outlined. Finally, we briefly review the testing procedure of accelerator superconducting magnets, underlining the close connection with the design validation and with the manufacturing process

  3. Manufacturing and Testing of Accelerator Superconducting Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, L [European Organization for Nuclear Research, Geneva (Switzerland)

    2014-07-01

    Manufacturing of superconducting magnet for accelerators is a quite complex process that is not yet fully industrialized. In this paper, after a short history of the evolution of the magnet design and construction, we review the main characteristics of the accelerator magnets having an impact on the construction technology. We put in evidence how the design and component quality impact on construction and why the final product calls for a total-quality approach. LHC experience is widely discussed and main lessons are spelled out. Then the new Nb3Sn technology, under development for the next generation magnet construction, is outlined. Finally, we briefly review the testing procedure of accelerator superconducting magnets, underlining the close connection with the design validation and with the manufacturing process.

  4. The first acceleration test of polarized protons in KEK PS

    International Nuclear Information System (INIS)

    Hiramatsu, Shigenori; Sato, Hikaru; Toyama, Takeshi

    1984-03-01

    The outline of the polarized proton acceleration project at KEK and the results of the first acceleration test are described. Depolarization in the 500 MeV booster synchrotron was investigated as the first step of this program. The beam polarization was measured in the 20 MeV beam transport line from the linac to the booster and in the main ring at the injection energy. About 40 % of the linac beam polarization was kept in the main ring. This acceleration test encouraged us to proceed with this program. (author)

  5. Accelerated Performance Testing on the 2006 NCAT Pavement Test Track

    Science.gov (United States)

    2009-12-01

    The original National Center for Asphalt Technology (NCAT) Pavement Test Track was built in 2000 in Opelika, Alabama where it has served as a state-of-the-art, full-scale, closed-loop accelerated loading facility. The construction, operation, and res...

  6. Comparison of leach results from field and laboratory prepared samples

    International Nuclear Information System (INIS)

    Oblath, S.B.; Langton, C.A.

    1985-01-01

    The leach behavior of saltstone prepared in the laboratory agrees well with that from samples mixed in the field using the Littleford mixer. Leach rates of nitrates and cesium from the current reference formulation saltstone were compared. The laboratory samples were prepared using simulated salt solution; those in the field used Tank 50 decontaminated supernate. For both nitrate and cesium, the field and laboratory samples showed nearly identical leach rates for the first 30 to 50 days. For the remaining period of the test, the field samples showed higher leach rates with the maximum difference being less than a factor of three. Ruthenium and antimony were present in the Tank 50 supernate in known amounts. Antimony-125 was observed in the leachate and a fractional leach rate was calculated to be at least a factor of ten less than that of 137 Cs. No 106 Ru was observed in the leachate, and the release rate was not calculated. However, based on the detection limits for the analysis, the ruthenium leach rate must also be at least a factor of ten less than cesium. These data are the first measurements of the leach rates of Ru and Sb from saltstone. The nitrate leach rates for these samples were 5 x 10 -5 grams of nitrate per square cm per day after 100 days for the laboratory samples and after 200 days for the field samples. These values are consistent with the previously measured leach rates for reference formulation saltstone. The relative standard deviation in the leach rate is about 15% for the field samples, which all were produced from one batch of saltstone, and about 35% for the laboratory samples, which came from different batches. These are the first recorded estimates of the error in leach rates for saltstone

  7. Solidified structure and leaching properties of metallurgical wastewater treatment sludge after solidification/stabilization process.

    Science.gov (United States)

    Radovanović, Dragana Đ; Kamberović, Željko J; Korać, Marija S; Rogan, Jelena R

    2016-01-01

    The presented study investigates solidification/stabilization process of hazardous heavy metals/arsenic sludge, generated after the treatment of the wastewater from a primary copper smelter. Fly ash and fly ash with addition of hydrated lime and Portland composite cement were studied as potential binders. The effectiveness of the process was evaluated by unconfined compressive strength (UCS) testing, leaching tests (EN 12457-4 and TCLP) and acid neutralization capacity (ANC) test. It was found that introduction of cement into the systems increased the UCS, led to reduced leaching of Cu, Ni and Zn, but had a negative effect on the ANC. Gradual addition of lime resulted in decreased UCS, significant reduction of metals leaching and high ANC, due to the excess of lime that remained unreacted in pozzolanic reaction. Stabilization of more than 99% of heavy metals and 90% of arsenic has been achieved. All the samples had UCS above required value for safe disposal. In addition to standard leaching tests, solidificates were exposed to atmospheric conditions during one year in order to determine the actual leaching level of metals in real environment. It can be concluded that the EN 12457-4 test is more similar to the real environmental conditions, while the TCLP test highly exaggerates the leaching of metals. The paper also presents results of differential acid neutralization (d-AN) analysis compared with mineralogical study done by scanning electron microscopy and X-ray diffraction analysis. The d-AN coupled with Eh-pH (Pourbaix) diagrams were proven to be a new effective method for analysis of amorphous solidified structure.

  8. Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing - Part 2

    Science.gov (United States)

    Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerome C.; Kolody, Mark R.

    2012-01-01

    Evaluation of metals to predict service life of metal-based structures in corrosive environments has long relied on atmospheric exposure test sites. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions similar to those of the corrosive environment. Their reliability to correlate to atmospheric exposure test results is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated corrosion testing has yet to be universally accepted as a useful tool in predicting the long-term service life of a metal, despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard, and their use is crucial, a method that correlates timescales from accelerated testing to atmospheric exposure would be very valuable. This paper presents work that began with the characterization of the atmospheric environment at the Kennedy Space Center (KSC) Beachside Corrosion Test Site. The chemical changes that occur on low carbon steel, during atmospheric and accelerated corrosion conditions, were investigated using surface chemistry analytical methods. The corrosion rates and behaviors of panels subjected to long-term and accelerated corrosion conditions, involving neutral salt fog and alternating seawater spray, were compared to identify possible timescale correlations between accelerated and long-term corrosion performance. The results, as well as preliminary findings on the correlation investigation, are presented.

  9. Chlorination leaching of cadmium

    International Nuclear Information System (INIS)

    Lach, E.; Pajak, I.; Bojanowska, A.

    1978-01-01

    The results of the investigations on chlorination leaching of cadmium from dust coming from dry dust collector of sinter belt, that is leaching with water saturated with gaseous chlorine and leaching with solutions of ammonium chloride and sodium chloride were given. The optimum conditions for these processes were established. It was found, that the method of leaching in the presence of gaseous chlorine is more effective, as it allows to report into the solution over 90% cadmium contained in dust. Owing to technical difficulties, environmental protection and safety conditions more advantageous seems to be the use as leaching agent of the ammonium chloride solutions. When applying 20% NH 4 Cl and temperature of 60 0 C, the time of 2 hours and the ratio of solid to liquid of 1:5, 70% cadmium contained in the dust can be reported into the solution. (auth.)

  10. Leaching of Titanium and Silicon from Low-Grade Titanium Slag Using Hydrochloric Acid Leaching

    Science.gov (United States)

    Zhao, Longsheng; Wang, Lina; Qi, Tao; Chen, Desheng; Zhao, Hongxin; Liu, Yahui; Wang, Weijing

    2018-05-01

    Acid-leaching behaviors of the titanium slag obtained by selective reduction of vanadium-bearing titanomagnetite concentrates were investigated. It was found that the optimal leaching of titanium and silicon were 0.7% and 1.5%, respectively. The titanium and silicon in the titanium slag were firstly dissolved in the acidic solution to form TiO2+ and silica sol, and then rapidly reprecipitated, forming hydrochloric acid (HCl) leach residue. Most of the silicon presented in the HCl leach residue as floccules-like silica gel, while most of the titanium was distributed in the nano-sized rod-like clusters with crystallite refinement and intracrystalline defects, and, as such, 94.3% of the silicon was leached from the HCl leach residue by alkaline desilication, and 96.5% of the titanium in the titanium-rich material with some rutile structure was then digested by the concentrated sulfuric acid. This provides an alternative route for the comprehensive utilization of titanium and silicon in titanium slag.

  11. Cosmological consistency tests of gravity theory and cosmic acceleration

    Science.gov (United States)

    Ishak-Boushaki, Mustapha B.

    2017-01-01

    Testing general relativity at cosmological scales and probing the cause of cosmic acceleration are among the important objectives targeted by incoming and future astronomical surveys and experiments. I present our recent results on consistency tests that can provide insights about the underlying gravity theory and cosmic acceleration using cosmological data sets. We use statistical measures, the rate of cosmic expansion, the growth rate of large scale structure, and the physical consistency of these probes with one another.

  12. Immobilized waste leaching

    International Nuclear Information System (INIS)

    Suarez, A.A.

    1989-01-01

    The main mechanism by which the immobilized radioactive materials can return to biosphere is the leaching due to the intrusion of water into the repositories. Some mathematical models and experiments utilized to evaluate the leaching rates in different immobilization matrices are described. (author) [pt

  13. The BNL Accelerator Test Facility and experimental program

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; State Univ. of New York, Stony Brook, NY

    1992-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high-power laser pulses synchronized to the electron beam, suitable for studies of new methods of high-gradient acceleration and state-of-the-art Free-Electron Lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps ND:YAG laser and a 500 mJ, 10 to 100 ps C0 2 laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various laser acceleration schemes, Free-Electron Laser experiments and a program on the development of high-brightness electron beams. The ATF's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the high-power laser will begin operation this year

  14. The BNL Accelerator Test Facility and experimental program

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; State Univ. of New York, Stony Brook, NY

    1991-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high power laser pulses synchronized to the electron beam, suitable for studies of new methods of high gradient acceleration and state of the art free electron lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 to 100 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps Nd:YAG laser and a 100 mJ, 10 ps CO 2 laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various acceleration schemes, Free-Electron Laser experiments and a program on the development of high brightness electron beams. The AFT's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the High power laser will begin operation this year. 28 refs., 4 figs

  15. On the application of design of experiments to accelerated life testing

    International Nuclear Information System (INIS)

    Hakim-Mashhadi, M.

    1992-01-01

    Today, there is an increasing demand for improved quality and reliability due to increasing system complexity and increasing demands from customer. Continuous improvement of quality is not only a means of competition but also a matter of staying in the market. Accelerated life testing and statistical design of experiments are two needed methods for improvement of quality. The combined use of them is very advantageous and increases the test efficiency. Accelerated life testing is a quick way to provide information on the life distribution of materials and products. By subjecting the test unit to conditions more severe than those at normal usage, the test time can be highly reduced. Estimates of life at normal stress levels are obtained by extrapolating the available information through a reasonable acceleration model. Accelerated life testing has mostly been used to measure reliability but it is high time to use it for improvement of quality. Design of experiments serves to find out the effect of design parameters and other interesting factors on performance measure and its variability. The obtained information is essential for a continuous improvement of quality. As an illustration, two sets of experiment are designed and performed at highly increased stress levels. The results are analysed and discussed and a time saving alternative is proposed. The combination of experimental design and accelerated life testing is discussed and illustrated. The combined use of these methods can be argued for in two different cases. One is for an exploratory improvement investigation and the other is for verification of reliability. In either case, the combined use is advantageous and improves the testing efficiency. Some general conclusions are drawn to be used for planning and performance of statistically designed accelerated life testing experiments. (70 refs.) (au)

  16. Chemical characterization, leach, and adsorption studies of solidified low-level wastes

    International Nuclear Information System (INIS)

    Walter, M.B.; Serne, R.J.; Jones, T.L.; McLaurine, S.B.

    1986-12-01

    Laboratory and field leaching experiments are beig conducted by Pacific Northwest Laboratory (PNL) to investigate the performance of solidified low-level nuclear waste in a typical, arid, near-surface disposal site. Under PNL's Special Waste Form Lysimeters-Arid Program, a field test facility was constructed to monitor the leaching of commercial solidified waste. Laboratory experiments were conducted to investigate the leaching and adsorption characteristics of the waste forms in contact with soil. Liquid radioactive wastes solidified in cement, vinyl ester-styrene, and bitumen were obtained from commercial boiling water and pressurized water reactors, and buried in a field leaching facility on the Hanford site in southeastern Washington State. Batch leaching, soil column adsorption, and soil/waste form column experiments were conducted in the laboratory, using small-scale cement waste forms and Hanford site ground water. The purpose of these experiments is to evaluate the ability of laboratory leaching tests to predict leaching under actual field conditions and to determine which mechanisms (i.e., diffusion, solubility, adsorption) actually control the concentration of radionuclides in the soil surrounding the waste form. Chemical and radionuclide analyses performed on samples collected from the field and laboratory experiments indicate strong adsorption of /sup 134,137/Cs and 85 Sr onto the Hanford site sediment. Small amounts of 60 Co are leached from the waste forms as very mobile species. Some 60 Co migrated through the soil at the same rate as water. Chemical constituents present in the reactor waste streams also found at elevated levels in the field and laboratory leachates include sodium, sulfate, magnesium, and nitrate. Plausible solid phases that could be controlling some of the chemical and radionuclide concentrations in the leachate were identified using the MINTEQ geochemical computer code

  17. Colorimetric detection of trace copper ions based on catalytic leaching of silver-coated gold nanoparticles.

    Science.gov (United States)

    Lou, Tingting; Chen, Lingxin; Chen, Zhaopeng; Wang, Yunqing; Chen, Ling; Li, Jinhua

    2011-11-01

    A colorimetric, label-free, and nonaggregation-based silver coated gold nanoparticles (Ag/Au NPs) probe has been developed for detection of trace Cu(2+) in aqueous solution, based on the fact that Cu(2+) can accelerate the leaching rate of Ag/Au NPs by thiosulfate (S(2)O(3)(2-)). The leaching of Ag/Au NPs would lead to dramatic decrease in the surface plasmon resonance (SPR) absorption as the size of Ag/Au NPs decreased. This colorimetric strategy based on size-dependence of nanoparticles during their leaching process provided a highly sensitive (1.0 nM) and selective detection toward Cu(2+), with a wide linear detection range (5-800 nM) over nearly 3 orders of magnitude. The cost-effective probe allows rapid and sensitive detection of trace Cu(2+) ions in water samples, indicating its potential applicability for the determination of copper in real samples.

  18. Sequential accelerated tests: Improving the correlation of accelerated tests to module performance in the field

    Science.gov (United States)

    Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John

    2016-09-01

    DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.

  19. Standard test method for static leaching of monolithic waste forms for disposal of radioactive waste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a measure of the chemical durability of a simulated or radioactive monolithic waste form, such as a glass, ceramic, cement (grout), or cermet, in a test solution at temperatures <100°C under low specimen surface- area-to-leachant volume (S/V) ratio conditions. 1.2 This test method can be used to characterize the dissolution or leaching behaviors of various simulated or radioactive waste forms in various leachants under the specific conditions of the test based on analysis of the test solution. Data from this test are used to calculate normalized elemental mass loss values from specimens exposed to aqueous solutions at temperatures <100°C. 1.3 The test is conducted under static conditions in a constant solution volume and at a constant temperature. The reactivity of the test specimen is determined from the amounts of components released and accumulated in the solution over the test duration. A wide range of test conditions can be used to study material behavior, includin...

  20. Leaching of uranium and thorium from monazite: III. Leaching of radiogenic daughters

    International Nuclear Information System (INIS)

    Olander, D.; Eyal, Y.

    1990-01-01

    The solid-state diffusion model of actinide leaching developed in Part II of this series is applied to leaching of radiogenic daughters of the actinide decay chains. For an untreated natural monazite, the direct leaching component of 228 Th release is larger than that for 232 Th because of enhanced solid-state mobility for 228 Th provided by 228 Ra-recoil tracks. A significant portion of the 228 Th which appears in the leachate, however, is attributed to decay of insoluble 228 Ra which is continually released from the mineral by matrix dissolution and recoil ejection. For a monazite sample that was annealed at 800 degree C prior to leaching, the bulk of the 228 Th in solution was supplied by decay of 228 Ra rejected from the mineral matrix during annealing. The radiogenic 234 U daughter of the 238 U decay chain did not exhibit similarly enhanced leaching because the long half-life of 234 U permitted local radiation damage to be annealed out at ambient temperature prior to 234 U decay

  1. Accelerated storage testing of freeze-dried Pseudomonas ...

    African Journals Online (AJOL)

    Accelerated storage testing of freeze-dried Pseudomonas fluorescens BTP1, ... of all P. fluorescens strains were not significantly different and thermal inactivation ... useful to the development of improved reference materials and samples held ...

  2. Nitrate Leaching Management

    Science.gov (United States)

    Nitrate (NO3) leaching is a significant nitrogen (N) loss process for agriculture that must be managed to minimize NO3 enrichment of groundwater and surface waters. Managing NO3 leaching should involve the application of basic principles of understanding the site’s hydrologic cycle, avoiding excess ...

  3. Nitrate leaching index

    Science.gov (United States)

    The Nitrate Leaching Index is a rapid assessment tool that evaluates nitrate (NO3) leaching potential based on basic soil and climate information. It is the basis for many nutrient management planning efforts, but it has considerable limitations because of : 1) an oversimplification of the processes...

  4. Sensitive Pb(2+) probe based on the fluorescence quenching by graphene oxide and enhancement of the leaching of gold nanoparticles.

    Science.gov (United States)

    Shi, Xinhao; Gu, Wei; Peng, Weidong; Li, Bingyu; Chen, Ningning; Zhao, Kai; Xian, Yuezhong

    2014-02-26

    A novel strategy was developed for fluorescent detection of Pb(2+) in aqueous solution based on the fact that graphene oxide (GO) could quench the fluorescence of amino pyrene (AP)-grafted gold nanoparticles (AP-AuNPs) and Pb(2+) could accelerate the leaching rate of AuNPs in the presence of S2O3(2-). In this system, fluorescence reporter AP was grafted on AuNPs through the Au-N bond. In the presence of GO, the system shows fluorescence quenching because of π-π stacking between AP and GO. With the addition of Pb(2+) and S2O3(2-), the system displays fluorescence recovery, which is attributed to the fact that Pb(2+) could accelerate the leaching of the AuNPs from GO surfaces and release of AP into aqueous solution. Interestingly, the concentration of GO could control the fluorescence "turn-off" or "turn-on" for Pb(2+) detection. In addition, GO is also an excellent promoter for the acceleration of the leaching of AuNPs and shortening the analytical time to ∼15 min. Under the optimal conditions, the fluorescence Pb(2+) sensor shows a linear range from 2.0 × 10(-9) to 2.3 × 10(-7) mol/L, with a detection limit of 1.0 × 10(-10) mol/L.

  5. Ultra-accelerated natural sunlight exposure testing

    Science.gov (United States)

    Jorgensen, Gary J.; Bingham, Carl; Goggin, Rita; Lewandowski, Allan A.; Netter, Judy C.

    2000-06-13

    Process and apparatus for providing ultra accelerated natural sunlight exposure testing of samples under controlled weathering without introducing unrealistic failure mechanisms in exposed materials and without breaking reciprocity relationships between flux exposure levels and cumulative dose that includes multiple concurrent levels of temperature and relative humidity at high levels of natural sunlight comprising: a) concentrating solar flux uniformly; b) directing the controlled uniform sunlight onto sample materials in a chamber enclosing multiple concurrent levels of temperature and relative humidity to allow the sample materials to be subjected to accelerated irradiance exposure factors for a sufficient period of time in days to provide a corresponding time of about at least a years worth of representative weathering of the sample materials.

  6. Quantification of the effects of environmental leaching factors on emissions from bottom ash in road construction.

    Science.gov (United States)

    Ecke, Holger; Aberg, Annika

    2006-06-01

    The re-use of bottom ash in road construction necessitates a tool to predict the impact of trace metals on the surroundings over the lifetime of the road. The aim of this work was to quantify the effect of environmental factors that are supposed to influence leaching, so as to suggest guidelines in developing a leaching procedure for the testing of incineration residues re-used in road constructions. The effects of pH, L/S (liquid-to-solid ratio), leaching time, and leaching atmosphere on the leachate concentrations of Cd, Cr, Cu, Ni, Pb, and Zn were studied using a two-level full factorial design. The most significant factor for all responses was the pH, followed by L/S, though the importance of pH and L/S is often ignored in leaching tests. Multiple linear regression models describing the variation in leaching data had R(2) values ranging from 61-97%. A two-step pH-stat leaching procedure that considers pH as well as L/S and leaching time was suggested.

  7. Studies of dynamic and static leaching of cemented and uncemented sorption material loaded with iodine-129

    International Nuclear Information System (INIS)

    Furrer, J.

    1989-05-01

    Leaching tests with water and brines were conducted on AC 6120 iodine sorption material (12 wt.% Ag) in order to improve the assessment of the behaviour of radioactive waste stored in a repository mine (salt or iron ore). As a result of the dynamic and static leaching tests, the leached fraction of I-129 in the uncemented material was found to be -1 %, while that of the cemented iodine sorption material was found to be -2 %. After ordinary steel had been added to the cemented sorption material, the leached fractions found were identical to those measured in uncemented material. The addition of stainless steel had only little influence on the leached fraction. (author)

  8. EBR-II blanket fuel leaching test using simulated J-13 well water.

    Energy Technology Data Exchange (ETDEWEB)

    Fonnesbeck, J. E.

    1998-05-15

    A pulsed-flow leaching test is being conducted using three EBR-II blanket fuel segments. These samples are immersed in simulated J-13 well water. The samples are kept at a constant temperature of 90 C. Leachate is exchanged weekly and analyzed for various nuclides which are of interest from a mobility and longevity point of view. Our primary interest is in the longer-lived species such as {sup 99}Tc, {sup 237}Np, and {sup 241}Am. In addition, the behavior of U, Pu, {sup 90}Sr, and {sup 137}Cs are being analyzed. During the course of this experiment, an interesting observation has been made involving one of the samples which could indicate the possible rapid ''anoxic'' oxidation of uranium metal to UO{sub 2}.

  9. Accelerated weathering of fire-retardant-treated wood for fire testing

    Science.gov (United States)

    Robert H. White

    2009-01-01

    Fire-retardant-treated products for exterior applications must be subjected to actual or accelerated weathering prior to fire testing. For fire-retardant-treated wood, the two accelerated weathering methods have been Method A and B of ASTM D 2898. The rain test is Method A of ASTM D 2898. Method B includes exposures to ultraviolet (UV) sunlamps in addition to water...

  10. Next Linear Collider Test Accelerator conceptual design report

    International Nuclear Information System (INIS)

    1993-08-01

    This document presents the scientific justification and the conceptual design for the open-quotes Next Linear Collider Test Acceleratorclose quotes (NLCTA) at SLAC. The goals of the NLCTA are to integrate the new technologies of X-band accelerator structures and rf systems being developed for the Next Linear Collider, to measure the growth of the open-quotes dark currentclose quotes generated by rf field emission in the accelerator, to demonstrate multi-bunch beam-loading energy compensation and suppression of higher-order deflecting modes, and to measure any transverse components of the accelerating field. The NLCTA will be a 42-meter-long beam line consisting, consecutively, of a thermionic-cathode gun, an X-band buncher, a magnetic chicane, six 1.8-meter-long sections of 11.4-GHz accelerator structure, and a magnetic spectrometer. Initially, the unloaded accelerating gradient will be 50 MV/m. A higher-gradient upgrade option eventually would increase the unloaded gradient to 100 MV/m

  11. Accelerated aging as vigor test for sunn hemp seeds

    OpenAIRE

    Silva, Clíssia Barboza da; Barbosa, Rafael Marani; Vieira, Roberval Daiton

    2016-01-01

    ABSTRACT: This study aimed to determine the most appropriate method to assess the sunn hemp ( Crotalaria juncea L.) seed vigor in the accelerated aging test. Five seed lots from harvest 2007/2008 were evaluated for germination, vigor and seedling emergence in the field. Accelerated aging test was performed at 41°C during 48, 72 and 96 hours, with and without sodium chloride saturated solution. Then, the promising procedure was also performed for 2008/2009 and 2009/2010 harvests. In the tradit...

  12. Accelerated aging as vigor test for sunn hemp seeds

    OpenAIRE

    Silva,Clíssia Barboza da; Barbosa,Rafael Marani; Vieira,Roberval Daiton

    2017-01-01

    ABSTRACT: This study aimed to determine the most appropriate method to assess the sunn hemp ( Crotalaria juncea L.) seed vigor in the accelerated aging test. Five seed lots from harvest 2007/2008 were evaluated for germination, vigor and seedling emergence in the field. Accelerated aging test was performed at 41°C during 48, 72 and 96 hours, with and without sodium chloride saturated solution. Then, the promising procedure was also performed for 2008/2009 and 2009/2010 harvests. In the tradit...

  13. Testing of Composite Fan Vanes With Erosion-Resistant Coating Accelerated

    Science.gov (United States)

    Bowman, Cheryl L.; Sutter, James K.; Otten, Kim D.; Samorezov, Sergey; Perusek, Gail P.

    2004-01-01

    The high-cycle fatigue of composite stator vanes provided an accelerated life-state prior to insertion in a test stand engine. The accelerated testing was performed in the Structural Dynamics Laboratory at the NASA Glenn Research Center under the guidance of Structural Mechanics and Dynamics Branch personnel. Previous research on fixturing and test procedures developed at Glenn determined that engine vibratory conditions could be simulated for polymer matrix composite vanes by using the excitation of a combined slip table and electrodynamic shaker in Glenn's Structural Dynamics Laboratory. Bench-top testing gave researchers the confidence to test the coated vanes in a full-scale engine test.

  14. Decontamination of Soils Contaminated with Co and Cs by Using an Acid Leaching Process

    International Nuclear Information System (INIS)

    Jung-Joon, Lee; Gye-Nam, Kim; Jei-Kwon, Moon; Kune-Woo, Lee

    2009-01-01

    Acid leaching process has been adapted for the remediation of soils contaminated with heavy metals and radionuclides. This method has been reported to be simple, and economically promising. Moreover it can be applicable for on-site and off-site remediations as well. Investigations were conducted on an acid leaching process using surrogate contaminated soils. Size sieving, agglomeration and column leaching were carried out with soils artificially contaminated with Co and Cs, respectively. Size distribution was analyzed for a determination of the particle size required to be agglomerated. Because of the low water permeability of the soils due to their fine particles, they were sieved by using a sieve with a 0.075 mm size (No. 200 mesh) for an agglomeration. The soils with a size smaller than 0.075 mm were agglomerated by using 2 % sodium silicate (Na 2 SiO 3 ), while the soils with a size larger than 0.075 mm were used directly for the column leaching test. From the preliminary test (the batch scale leaching test), 0.1 M of HCl was determined as the effective leaching agent for Co and Cs. Finally, the soils mixed with the coarse soil and the agglomerated soil were decontaminated with 0.1 M HCl within 11.3 days and the removal efficiencies of Co and Cs were 94.0 % and 82.8 %, respectively. In conclusion, an acid leaching process could be applied for a remediation of soils contaminated with radionuclides such as Co and Cs. (authors)

  15. A comparative study of accelerated tests to simulate atmospheric corrosion

    International Nuclear Information System (INIS)

    Assis, Sergio Luiz de

    2000-01-01

    In this study, specimens coated with five organic coating systems were exposed to accelerated tests for periods up to 2000 hours, and also to weathering for two years and six months. The accelerated tests consisted of the salt spray test, according to ASTM B-117; Prohesion (ASTM G 85-98 annex 5A); Prohesion combined with cyclic exposure to UV-A radiation and condensation; 'Prohchuva' a test described by ASTM G 85-98 using a salt spray with composition that simulated the acid rain of Sao Paulo, but one thousand times more concentrated, and 'Prohchuva' combined with cyclic exposure to UV-A radiation and condensation. The coated specimens were exposed with and without incision to expose the substrate. The onset and progress of corrosion at and of the exposed metallic surface, besides coating degradation, were followed by visual observation, and photographs were taken. The coating systems were classified according to the extent of corrosion protection given to the substrate, using a method based on ASTM standards D-610, D-714, D-1654 and D-3359. The rankings of the coatings obtained from accelerated tests and weathering were compared and contrasted with classification of the same systems obtained from literature, for specimens exposed to an industrial atmosphere. Coating degradation was strongly dependent on the test, and could be attributed to differences in test conditions. The best correlation between accelerated test and weathering was found for the test Prohesion alternated with cycles of exposure to UV-A radiation and condensation. (author)

  16. Accelerated spike resampling for accurate multiple testing controls.

    Science.gov (United States)

    Harrison, Matthew T

    2013-02-01

    Controlling for multiple hypothesis tests using standard spike resampling techniques often requires prohibitive amounts of computation. Importance sampling techniques can be used to accelerate the computation. The general theory is presented, along with specific examples for testing differences across conditions using permutation tests and for testing pairwise synchrony and precise lagged-correlation between many simultaneously recorded spike trains using interval jitter.

  17. Model- and calibration-independent test of cosmic acceleration

    International Nuclear Information System (INIS)

    Seikel, Marina; Schwarz, Dominik J.

    2009-01-01

    We present a calibration-independent test of the accelerated expansion of the universe using supernova type Ia data. The test is also model-independent in the sense that no assumptions about the content of the universe or about the parameterization of the deceleration parameter are made and that it does not assume any dynamical equations of motion. Yet, the test assumes the universe and the distribution of supernovae to be statistically homogeneous and isotropic. A significant reduction of systematic effects, as compared to our previous, calibration-dependent test, is achieved. Accelerated expansion is detected at significant level (4.3σ in the 2007 Gold sample, 7.2σ in the 2008 Union sample) if the universe is spatially flat. This result depends, however, crucially on supernovae with a redshift smaller than 0.1, for which the assumption of statistical isotropy and homogeneity is less well established

  18. Evaluation of long-term leaching of borosilicate glass in pure water

    International Nuclear Information System (INIS)

    Lanza, F.; Parnisari, E.

    1979-01-01

    In order to confirm the validity of the model of the dissolving sphere, a series of tests of leaching of borosilicate glasses has been performed. The leaching rate is followed by measurements of weight loss and analysis of the surface composition. An accumulation at the surface of the less soluble cations is observed

  19. Framework for a Comparative Accelerated Testing Standard for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Wohlgemuth, J.; Yamamichi, M.; Sample, T.; Miller, D.; Meakin, D.; Monokroussos, C.; TamizhMani, M.; Kempe, M.; Jordan, D.; Bosco, N.; Hacke, P.; Bermudez, V.; Kondo, M.

    2013-08-01

    As the photovoltaic industry has grown, the interest in comparative accelerated testing has also grown. Private test labs offer testing services that apply greater stress than the standard qualification tests as tools for differentiating products and for gaining increased confidence in long-term PV investments. While the value of a single international standard for comparative accelerated testing is widely acknowledged, the development of a consensus is difficult. This paper strives to identify a technical basis for a comparative standard.

  20. Frequency of use controls chemical leaching from drinking-water containers subject to disinfection.

    Science.gov (United States)

    Andra, Syam S; Makris, Konstantinos C; Shine, James P

    2011-12-15

    Microbial-, and chemical-based burden of disease associated with lack of access to safe water continues to primarily impact developing countries. Cost-effective health risk-mitigating measures, such as of solar disinfection applied to microbial-contaminated water stored in plastic bottles have been increasingly tested in developing countries adversely impacted by epidemic water-borne diseases. Public health concerns associated with chemical leaching from water packaging materials led us to investigate the magnitude and variability of antimony (Sb) and bromine (Br) leaching from reused plastic containers (polyethylene terephthalate, PET; and polycarbonate, PC) subject to UV and/or temperature-driven disinfection. The overall objective of this study was to determine the main and interactive effects of temperature, UV exposure duration, and frequency of bottle reuse on the extent of leaching of Sb and Br from plastic bottles into water. Regardless of UV exposure duration, frequency of reuse (up to 27 times) was the major factor that linearly increased Sb leaching from PET bottles at all temperatures tested (13-47 °C). Leached Sb concentrations (∼360 ng L(-1)) from the highly reused (27 times) PET bottles (minimal Sb leaching from PC bottles, water at much lower concentrations. Additional research on potential leaching of organic chemicals from water packaging materials is deemed necessary under relevant environmental conditions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Investigation of ATR-FTIR spectroscopy as an alternative to the Water Leach Free Acidity test for cellulose acetate-based film

    DEFF Research Database (Denmark)

    Johansen, Karin Bonde; Shashoua, Yvonne

    2005-01-01

    Cellulose acetate film loses acetate groups on ageing which results in the formation of damaging acetic acid. Water-Leach Free Acidity Test (WLFAT) is the definitive technique to quantify acidity, but requires 1g film and 26 hours. ATR-FTIR spectroscopy is a non-destructive, rapid technique which...

  2. Leaching Behavior of Heavy Metals from Cement Pastes Using a Modified Toxicity Characteristic Leaching Procedure (TCLP).

    Science.gov (United States)

    Huang, Minrui; Feng, Huajun; Shen, Dongsheng; Li, Na; Chen, Yingqiang; Shentu, Jiali

    2016-03-01

    As the standard toxicity characteristic leaching procedure (TCLP) can not exhaust the acid neutralizing capacity of the cement rotary kiln co-processing solid wastes products which is particularly important for the assessment of the leaching concentrations of heavy metals. A modified TCLP was proposed. The extent of leaching of heavy metals is low using the TCLP and the leaching performance of the different metals can not be differentiated. Using the modified TCLP, however, Zn leaching was negligible during the first 180 h and then sharply increased (2.86 ± 0.18 to 3.54 ± 0.26 mg/L) as the acidity increased (pH leaching is enhanced using the modified TCLP. While Pb leached readily during the first 126 h and then leachate concentrations decreased to below the analytical detection limit. To conclude, this modified TCLP is a more suitable method for these cement rotary kiln co-processing products.

  3. Analytical electron microscopy examination of solid reaction products in long-term test of SRL 200 waste glasses

    International Nuclear Information System (INIS)

    Buck, E.C.; Fortner, J.A.; Bates, J.K.; Feng, X.; Dietz, N.L.; Bradley, C.R.; Tani, B.S.

    1993-01-01

    Alteration phases, found on the leached surfaces and present as colloids in the leachates of 200-based frit (fully active and simulated) nuclear waste glass, reacted under static test conditions, at a surface area to leachate volume ratio of 20,000 m -1 for 15 days to 728 days, have been examined by analytical electron microscopy. The compositions of the secondary phases were determined using x-ray energy dispersive spectroscopy and electron energy loss spectroscopy, and structural analysis was accomplished by electron diffraction. Long-term samples of simulated glass, which had undergone an acceleration of reaction after 182 days, possessed a number of silicate secondary phases, including; smectite (iron silicate and potassium iron alumina-silicate, weeksite (uranium silicate), zeolite (calcium potassium alumino-silicate), tobermorite (calcium silicate), and a pure silica phase. However, uranium silicates and smectite have also been observed in tests, which have not undergone the acceleration of reaction, in both the leachate and leached layer, suggesting that these phases are not responsible for the acceleration of reaction

  4. Leaching of cadmium and tellurium from cadmium telluride (CdTe) thin-film solar panels under simulated landfill conditions

    Science.gov (United States)

    Ramos-Ruiz, Adriana; Wilkening, Jean V.; Field, James A.; Sierra-Alvarez, Reyes

    2017-01-01

    A crushed non-encapsulated CdTe thin-film solar cell was subjected to two standardized batch leaching tests (i.e., Toxicity Characteristic Leaching Procedure (TCLP) and California Waste Extraction Test (WET)) and to a continuous-flow column test to assess cadmium (Cd) and tellurium (Te) dissolution under conditions simulating the acidic- and the methanogenic phases of municipal solid waste landfills. Low levels of Cd and Te were solubilized in both batch leaching tests (leaching behavior of CdTe in the columns is related to different aqueous pH and redox conditions promoted by the microbial communities in the columns, and is in agreement with thermodynamic predictions. PMID:28472709

  5. Antimony leaching from MSWI bottom ash: modelling of the effect of pH and carbonation.

    Science.gov (United States)

    Cornelis, Geert; Van Gerven, Tom; Vandecasteele, Carlo

    2012-02-01

    Development of treatment methods to reduce Sb leaching from municipal solid waste incinerator (MSWI) bottom ash, such as accelerated carbonation, is being complicated by insufficient understanding of Sb geochemistry. The leaching of antimonate (Sb(V)) and antimonite (Sb(III)) in MSWI bottom was studied as a function of pH and degree of carbonation. While total (Sb(V)+Sb(III)) leaching was lowest (1.2 mg kg(-1)) at the natural pH (i.e. 10.6) of uncarbonated bottom ash, HPLC-ICP-MS analysis showed that acidification and carbonation increased Sb(V) leaching, but decreased Sb(III) leaching, probably because Sb(III)(OH)(4)(-) became less stable. PHREEQC geochemical modelling suggested that Sb(V) concentrations approached equilibrium with the romeites, i.e. calcium antimonates, Ca(1.13)Sb(2)(OH)(0.26)·0.74H(2)O at pH=10.6 and Ca[Sb(OH)(6)](2) at pH=8. It is hypothesised that not interaction with ettringite but dissolution of romeite controls antimonate leaching in the pH range 8-11 in MSWI bottom ash, because while Ca is preferentially leached from romeite, the mineral structures containing more Ca at higher pH are less soluble. A model was proposed where acidification and carbonation both lead to lower Ca(2+) and/or hydroxyl concentration, which removes Ca(2+) and hydroxyls from the romeite structure and leads to comparably higher Sb(V) concentration in equilibrium with romeite. Sb solubility depends on pH and Ca(2+) availability in this model, which has implications for bottom ash valorisation and risk assessment. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. The influence of additives on leaching of tritium of the immobilization matrices of contaminated oils by cementation

    International Nuclear Information System (INIS)

    Deneanu, N.; Dulama, M.; Baboescu, E.; Horhoianu, G.

    2000-01-01

    The research studies showed that the solidification of contaminated pump oils resulted from Cernavoda NPP operation can be done by using various immobilization matrices such as: cement with appropriate mineral additives sand of Aghires, lime and silicate accelerator. Research works and experiments were carried out on four groups: cement-emulsion, cement-emulsion-silicate accelerator, cement-emulsion-lime- silicate accelerator and cement-emulsion-sand of Aghires. The paper presents the author's research on immobilization of contaminated oil by cementation using Romanian emulsifiers. With both of the emulsifiers used, there were obtained reasonable compressive strengths and leaching rates. (author)

  7. Acid leaching of mixed spent Li-ion batteries

    Directory of Open Access Journals (Sweden)

    A.A. Nayl

    2017-05-01

    Full Text Available Acid leaching for different types of mixed spent Li-ion mobile batteries is carried out after alkali decomposition using NH4OH followed by H2SO4 + H2O2 leaching. In the alkali decomposition step, the effects of reaction time, NH4OH concentration, liquid/solid mass ratio and reaction temperature on the decomposition process are investigated to remove Al, Cu, Mn, Ni, Co, and Li. After alkaline treatment, the alkali paste is treated to leach the remaining metals using H2SO4 + H2O2. The significant effects of reaction time, acid concentration, H2O2 concentration, liquid/solid mass ratios and reaction temperature on the leaching rate are studied. More than 97% of Al, Mn, Ni, Co, and Li and about 65% Cu are leached in two stages. Kinetic analysis shows that, the data fit with chemical reaction control mechanism and the activation energies for the investigated metals using the Arrhenius equation ranged from 30.1 to 41.4 kJ/mol. Recovered metals are precipitated from the leaching liquor at varying pH values using NaOH solution and Na2CO3. Firstly, Mn is precipitated as MnCO3 at pH = 7.5. Secondly, at pH = 9.0, nickel is precipitated as NiCO3. Thirdly, as the pH of the leaching liquor reaches 11–12, Co(OH2 is precipitated and the remaining Li is readily precipitated as Li2CO3 using a saturated Na2CO3 solution. Based on the experimental data, a flow sheet is developed and tested for the recovery process.

  8. Biocide leaching during field experiments on treated articles.

    Science.gov (United States)

    Schoknecht, Ute; Mathies, Helena; Wegner, Robby

    2016-01-01

    Biocidal products can be sources of active substances in surface waters caused by weathering of treated articles. Marketing and use of biocidal products can be limited according to the European Biocidal Products Regulation if unacceptable risks to the environment are expected. Leaching of active substances from treated articles was observed in field experiments to obtain information on leaching processes and investigate the suitability of a proposed test method. Leaching under weathering conditions proceeds discontinuously and tends to decrease with duration of exposure. It does not only mainly depend on the availability of water but is also controlled by transport processes within the materials and stability of the observed substances. Runoff amount proved to be a suitable basis to compare results from different experiments. Concentrations of substances are higher in runoff collected from vertical surfaces compared to horizontal ones, whereas the leached amounts per surface area are higher from horizontal surfaces. Gaps in mass balances indicate that additional processes such as degradation and evaporation may be relevant to the fate of active substances in treated articles. Leached amounts of substances were considerably higher when the materials were exposed to intermittent water contact under laboratory conditions as compared to weathering of vertically exposed surfaces. Experiences from the field experiments were used to define parameters of a procedure that is now provided to fulfil the requirements of the Biocidal Products Regulation. The experiments confirmed that the amount of water which is in contact with exposed surfaces is the crucial parameter determining leaching of substances.

  9. The BNL Accelerator Test Facility control system

    International Nuclear Information System (INIS)

    Malone, R.; Bottke, I.; Fernow, R.; Ben-Zvi, I.

    1993-01-01

    Described is the VAX/CAMAC-based control system for Brookhaven National Laboratory's Accelerator Test Facility, a laser/linac research complex. Details of hardware and software configurations are presented along with experiences of using Vsystem, a commercial control system package

  10. The leaching characteristics of vitrified slag

    International Nuclear Information System (INIS)

    Zhang, Jinlong; Li, Yaojian; Tian, Junguo; Sheng, Hongzhi; Xu, Yongxiang

    2010-01-01

    Full Text: Plasma-arc technology was developed to fix the heavy metal of flying ash by the Institute of Mechanics, Chinese Academy of Sciences (CAS-IMECH). A direct current (DC) experimental facility of 30 kW with plasma-arc technology was setup to form vitrified slag. The additives (CaO, SiO 2 ) were added into the reactor to form vitrified slag and fix the heavy metal (Cr, Pb), under dissimilar condition (long and short heating-up time, natural and water cooling). Vitrified slag was broken into different particle size, from 0.1 mm to 1 cm. The particles with different specific surface area were used to study the leaching of heavy metals in vitrified slag rate of speed. The pH value of leaching solution are from 2 to 12, the experiment was kept at different external temperature, from 4 degree Celsius to 70 degree celsius, for 1 week to 1 month. Heavy metal leaching concentration was used to measure the chemical stability of vitrified slag. The results show that the higher specific surface area, the higher heavy metal leaching concentration, but when the specific surface area reaches a certain value, little change in leaching concentration. The impact of temperature on leaching concentration was not significant, from 4 degree Celsius to 70 degree Celsius. The leaching concentration increases with decreasing of the pH value of leaching solution when the pH value of leaching solution less than 7, and little change in concentration increases with pH value when the pH value of leaching solution more than 7. Compared with the leaching concentration after 1 month, the leaching concentration after 1 week has not changed significantly. (Author)

  11. Behaviour Test with the Leaching of a Waste package

    International Nuclear Information System (INIS)

    Fischer, G.R

    1999-01-01

    The radioactive wastes are classified, in low, intermediate and high level wastes, according to the characteristics of the radionuclides in, its specific activity and half-life.Those are the three parameters that indicate how long the radioactive waste will be keep confined, in safe conditions before its contaminants go into the environment or before the institutional controls on the final disposal installations are removed.The confinement time can be estimated in ten half-lives, because since that moment its activity has decayed at one thousandth from the original .In low level wastes the confinement periods are nearly fifty years while in intermediate level, the periods can be until three hundreds years.These times are normally controlled by government institutions that are in charge of looking after people about the no-liberation of toxic elements at the environment.Therefore the wastes can be confined in a motionless matrix so that they can be placed in shallow land burials.On the other hand, the high level wastes which confinement times are estimated in ten or so thousand years, must be disposed in deep underground geological repositories.Obviously, there are no state controls for them.There are several matrices or different ways of stabilizing a waste, that will be introduced in this essay.It is also important to take account into the factors that degrade those matrices and speed up the released time of the radionuclides into the environment.There have been analyzed too, the radionuclides transport process that go through the matrix and the factors that affect the aforesaid process.Moreover, the diffusion was studied in a such detailed way, assuming that it is the most important mass transport process, in agreement with other studies made before.The leach rates and the diffusion coefficients have been calculated and determinated by means of measurements in a full scale leaching test.Those coefficients were compared with small-scale laboratory and

  12. Coupling between chemical degradation and mechanical behaviour of leached concrete; Couplage degradation chimique - comportement en compression du beton

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, V H

    2005-10-15

    This work is in the context of the long term behavior of concrete employed in radioactive waste disposal. The objective is to study the coupled chemo-mechanical modelling of concrete. In the first part of this contribution, experimental investigations are described where the effects of the calcium leaching process of concrete on its mechanical properties are highlighted. An accelerated method has been chosen to perform this leaching process by using an ammonium nitrate solution. In the second part, we present a coupled phenomenological chemo-mechanical model that represents the degradation of concrete materials. On one hand, the chemical behavior is described by the simplified calcium leaching approach of cement paste and mortar. Then a homogenization approach using the asymptotic development is presented to take into account the influence of the presence of aggregates in concrete. And on the other hand, the mechanical part of the modelling is given. Here continuum damage mechanics is used to describe the mechanical degradation of concrete. The growth of inelastic strains observed during the mechanical tests is describes by means of a plastic like model. The model is established on the basis of the thermodynamics of irreversible processes framework. The coupled nonlinear problem at hand is addressed within the context of the finite element method. Finally, numerical simulations are compared with the experimental results for validation. (author)

  13. Acid pressure leaching of a concentrate containing uranium, thorium and rare earth elements

    International Nuclear Information System (INIS)

    Lan Xinghua; Peng Ruqing.

    1987-01-01

    The acid pressure leaching of a concentrate containing rinkolite for recovering uranium, thorium and rare earth elements is described. The laboratory and the pilot plant test results are given. Under the optimum leaching conditions, the recovery of uranium, thorium and rare earth elements are 82.9%, 86.0% and 88.3% respectively. These results show that the acid pressure leaching process is a effective process for treating the concentrate

  14. Accelerated testing for studying pavement design and performance (FY 2003) : research summary.

    Science.gov (United States)

    2008-01-01

    The Midwest States Accelerated Pavement Testing Pooled Fund Program, financed by : the highway departments of Missouri, Iowa, Kansas and Nebraska, has supported an : accelerated pavement testing (APT) project to compare the performance of stabilized ...

  15. SLAC High Gradient Testing of a KEK X-Band Accelerator Structure

    International Nuclear Information System (INIS)

    Loewen, Rod

    2000-01-01

    The high accelerating gradients required for future linear colliders demands a better study of field emission and RF breakdown in accelerator structures. Changes in structure geometry, vacuum pumping, fabrication methods, and surface finish can all potentially impact the conditioning process, dark current emission, and peak RF power handling capability. Recent tests at SLAC of KEK's ''M2'' travelling wave x-band accelerator section provides an opportunity to investigate some of these effects by comparing its performance to previously high power tested structures at SLAC. In addition to studying ultimate power limitations, this test also demonstrates the use of computer automated conditioning to reach practical, achievable gradients

  16. Defining Effective Salt Leaching Regions Between Drains

    OpenAIRE

    ANAPALI, Ömer; ŞAHİN, Üstün; ÖZTAŞ, Taşkın; HANAY, Abdurrahman

    2014-01-01

    The application of sufficient amounts of leaching water by means of an effective method is very important in the management and reclamation of saline and sodic soils. Reclamation cannot be achieved with insufficient leaching water application, while excess water application may cause severe problems in soil. Knowledge of the leaching regions and intensities may help to control the amounts of leaching water through effective leaching methods in areas of limited leaching. This study was und...

  17. Accelerated in-vitro release testing methods for extended-release parenteral dosage forms.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-07-01

    This review highlights current methods and strategies for accelerated in-vitro drug release testing of extended-release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in-situ depot-forming systems and implants. Extended-release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, 'real-time' in-vitro release tests for these dosage forms are often run over a long time period. Accelerated in-vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in-vitro release methods using United States Pharmacopeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended-release parenteral dosage forms, along with the accelerated in-vitro release testing methods currently employed are discussed. Accelerated in-vitro release testing methods with good discriminatory ability are critical for quality control of extended-release parenteral products. Methods that can be used in the development of in-vitro-in-vivo correlation (IVIVC) are desirable; however, for complex parenteral products this may not always be achievable. © 2012 The Authors. JPP © 2012 Royal Pharmaceutical Society.

  18. Accelerated in vitro release testing methods for extended release parenteral dosage forms

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J.

    2012-01-01

    Objectives This review highlights current methods and strategies for accelerated in vitro drug release testing of extended release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in situ depot-forming systems, and implants. Key findings Extended release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, “real-time” in vitro release tests for these dosage forms are often run over a long time period. Accelerated in vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in vitro release methods using United States Pharmacopoeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended release parenteral dosage forms, along with the accelerated in vitro release testing methods currently employed are discussed. Conclusions Accelerated in vitro release testing methods with good discriminatory ability are critical for quality control of extended release parenteral products. Methods that can be used in the development of in vitro-in vivo correlation (IVIVC) are desirable, however for complex parenteral products this may not always be achievable. PMID:22686344

  19. European accelerator facilities for single event effects testing

    Energy Technology Data Exchange (ETDEWEB)

    Adams, L; Nickson, R; Harboe-Sorensen, R [ESA-ESTEC, Noordwijk (Netherlands); Hajdas, W; Berger, G

    1997-03-01

    Single event effects are an important hazard to spacecraft and payloads. The advances in component technology, with shrinking dimensions and increasing complexity will give even more importance to single event effects in the future. The ground test facilities are complex and expensive and the complexities of installing a facility are compounded by the requirement that maximum control is to be exercised by users largely unfamiliar with accelerator technology. The PIF and the HIF are the result of experience gained in the field of single event effects testing and represent a unique collaboration between space technology and accelerator experts. Both facilities form an essential part of the European infrastructure supporting space projects. (J.P.N.)

  20. Investigation of leaching of an antifouling agent from marine paint formulations using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Kalgutkar, D.B.; Patil, S.P.; Jayachandran, N.; Unni, V.K.P.

    2012-01-01

    A radiotracer technique was used to investigate the leaching of an antifouling agent from different marine paint formulations with an objective to select the best paint formulation for bulk production. The antifouling agent (Diuron) itself was labeled with carbon-14 (half-life: 5,730 years, β-energy: 156 keV) and used as a radiotracer. The different paint formulations added with radiolabeled Diuron were applied onto suitably selected substrates and measured for initial intensity of β-radiation using a Geiger-Muller detector connected to a ratemeter. The painted substrates were subjected to shower tests for a pre-decided time and subsequently measured for β-radiations. The comparison of intensity of β-radiations in substrates prior and post shower tests provides information about leaching of antifouling agent Diuron from the paint formulation. The high leaching percentage of antifouling agent Diuron post shower tests indicates non-suitability of paint formulation for marine and civil structures. However, low leaching rate of Diuron will make a paint formulation more efficient and suitable. Based on the results of investigation, a paint formulation with minimum leaching rate was identified and selected for bulk production by a paint company. (author)

  1. An evaluation of arsenic release from monolithic solids using a modified semi-dynamic leaching test

    International Nuclear Information System (INIS)

    Dermatas, Dimitris; Moon, Deok Hyun; Menounou, Nektaria; Meng, Xiaoguang; Hires, Richard

    2004-01-01

    Quicklime and quicklime-fly ash-based stabilization/solidification (S/S) effectiveness was evaluated by performing semi-dynamic leaching tests (American Nuclear Society 16.1). Artificial soil samples, contaminated with arsenic trioxide (As 2 O 3 ) as well as field soil samples contaminated with arsenic (As) were tested. The artificial soils were prepared by mixing amounts of kaolinite or montmorillonite with fine quartz sand. The S/S effectiveness was evaluated by measuring effective diffusion coefficients (D e ) and leachability indices (LX). Treatment was most effective in kaolinite-based artificial soils treated with quicklime and in quicklime-fly ash treated field soils. The experimental results indicate that D e values were lowered as a result of S/S treatment. Upon treatment LX values were higher than 9, suggesting that S/S treated soils are acceptable for 'controlled utilization'. Based on a model developed by de Groot and van der Sloot [G.J. de Groot, H.A. van der Sloot, in: T.M. Gilliam, C.C. Wiles (Eds.), Stabilization and Solidification of Hazardous, Radioactive, and Mixed Wastes, vol. 2, ASTM STP 1123, ASTM, PA, 1992, p. 149], the leaching mechanism for all of the treated soils was found to be controlled by diffusion. The effect of soluble silica (Si) on As leachability was also evaluated. When soluble Si concentration was less than 1 ppm, As leachability was the lowest. The controlling mechanism of As immobilization whether sorption, precipitation, or inclusion was also evaluated. It was determined that precipitation was the dominant mechanism

  2. Accelerated testing for studying pavement design and performance (FY 2002) : research summary.

    Science.gov (United States)

    2004-01-01

    This report covers the Fiscal Year 2002 project conducted at the Accelerated Testing : Laboratory at Kansas State University. The project was selected and funded by the : Midwest States Accelerated Testing Pooled Fund Program, which includes Iowa, Ka...

  3. High gradient tests of SLAC Linear Collider Accelerator Structures

    International Nuclear Information System (INIS)

    Wang, J.W.; Deruyter, H.; Eichner, J.; Fant, K.H.; Hoag, H.A.; Koontz, R.F.; Lavine, T.; Loew, G.A.; Loewen, R.; Menegat, L.

    1994-08-01

    This paper describes the current SLAC R ampersand D program to develop room temperature accelerator structures for the Next Linear Collider (NLC). The structures are designed to operate at 11.4 GHz at an accelerating gradient in the range of 50 to 100 MV/m. In the past year a 26 cm constant-impedance traveling-wave section, a 75 cm constant-impedance traveling-wave section, and a 1.8 m traveling-wave section with detuned deflecting modes have been high-power tested. The paper presents a brief description of the RF test setup, the design and manufacturing details of the structures, and a discussion of test results including field emission, RF processing, dark current spectrum and RF breakdown

  4. Determination of fission gas release of spent nuclear fuel in puncturing test and in leaching experiments under anoxic conditions

    Energy Technology Data Exchange (ETDEWEB)

    González-Robles, E., E-mail: ernesto.gonzalez-robles@kit.edu [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Metz, V. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Wegen, D.H. [European Commission, Joint Research Centre, Institute for Transuranium Elements (JRC-ITU), P.O. Box 2340, 76125, Karlsruhe (Germany); Herm, M. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Papaioannou, D. [European Commission, Joint Research Centre, Institute for Transuranium Elements (JRC-ITU), P.O. Box 2340, 76125, Karlsruhe (Germany); Bohnert, E. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Gretter, R. [European Commission, Joint Research Centre, Institute for Transuranium Elements (JRC-ITU), P.O. Box 2340, 76125, Karlsruhe (Germany); Müller, N. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Nasyrow, R.; Weerd, W. de; Wiss, T. [European Commission, Joint Research Centre, Institute for Transuranium Elements (JRC-ITU), P.O. Box 2340, 76125, Karlsruhe (Germany); Kienzler, B. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany)

    2016-10-15

    During reactor operation the fission gases Kr and Xe are formed within the UO{sub 2} matrix of nuclear fuel. Their quantification is important to evaluate their impact on critical parameters regarding the fuel behaviour during irradiation and (long-term) interim storage, such as internal pressure of the fuel rod and fuel swelling. Moreover the content of Kr and Xe in the plenum of a fuel rod and their content in the UO{sub 2} fuel itself are widely used as indicators for the release properties of {sup 129}I, {sup 137}Cs, and other safety relevant radionuclides with respect to final disposal of spent nuclear fuel. The present study deals with the fission gas release from spent nuclear fuel exposed to simulated groundwater in comparison with the fission gas previously released to the fuel rod plenum during irradiation in reactor. In a unique approach we determined both the Kr and Xe inventories in the plenum by means of a puncturing test and in leaching experiments with a cladded fuel pellet and fuel fragments in bicarbonate water under 3.2 bar H{sub 2} overpressure. The fractional inventory of the fission gases released during irradiation into the plenum was (8.3 ± 0.9) %. The fraction of inventory of fission gases released during the leaching experiments was (17 ± 2) % after 333 days of leaching of the cladded pellet and (25 ± 2) % after 447 days of leaching of the fuel fragments, respectively. The relatively high release of fission gases in the experiment with fuel fragments was caused by the increased accessibility of water to the Kr and Xe occluded in the fuel.

  5. Mass spectrographic analysis of selected chemical elements by microbial leaching of zircon

    International Nuclear Information System (INIS)

    Becker, S.; Dietze, H.J.; Bullmann, M.; Iske, U.

    1986-01-01

    Spark source mass spectrometry is a useful method for chemical element analysis of geological and biological samples. This sensitive technique (detection limit down to the ppb-range) is used to analyze leaching processes by means of several microorganisms. The problem of microbial leaching of chemical resistent materials was tested under laboratory conditions with regard to possible analytical and technical applications. Leaching of metals with chemolithotrophic and heterotrophic, organic acids producing microorganisms has been investigated with zircon from the Baltic Shield containing 0.7% rare earth elements and 1.67% hafnium. When zircon is leached with strains of thiobacillus ferrooxidans about 80% of the rare earth elements, Hf, Th and U can be recovered. (orig.) [de

  6. Impact of aging on leaching characteristics of recycled concrete aggregate.

    Science.gov (United States)

    Abbaspour, Aiyoub; Tanyu, Burak F; Cetin, Bora

    2016-10-01

    The focus of this study was to evaluate the effects of stockpiling (aging) on leaching of elements in recycled concrete aggregate (RCA) that may contribute to tufaceous constituent formation. Speciation and leaching controlling mechanisms of these elements were identified via geochemical modeling. The effects of stockpiling were simulated by comparing freshly produced RCA with RCA aged as part of this study for 1 year both in the laboratory and in the field. Leachate samples were generated following batch water leach test (WLT) and US Geological Survey leach test (USGSLT) methods. USGSLTs were conducted both on the laboratory and field samples while WLT was only conducted on laboratory samples. During the laboratory aging, it is observed that the carbonate content of RCA, measured as calcite equivalent, increased 20 % (i.e., from ∼100 to 120 mg/g) within a year time frame. The leachate extracted from RCA showed minor changes in pH and more significant decreases in electrical conductivity (i.e., ∼300 to 100 μS/cm). A comparison between laboratory and field samples revealed that the RCA aged much slower in the field than in the laboratory within a year. Comparisons between two leach extraction methods on the laboratory conditions showed that the total leached concentrations (TLCs) of most of the constituents from USGSLT were appreciably lower than the ones measured via WLT method. The results of geochemical modeling analyses showed that Al, Si, Fe, Ca, Mg, and Cu exist in their oxidized forms as Al 3+ , Fe 3+ , Si 4+ , Ca 2+ , Mg 2+ , and Cu 2+ and results revealed that these elements are primarily controlled by the solubility of gibbsite, hematite, silica gel, calcite, magnesite, and tenorite solid phases, respectively. One of the significant findings of the study was to identify the changes in leaching behavior of Ca, Si, Mg, Al, Fe, and Cu due to carbonation.

  7. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Gannon, J.; Kraushaar, P.; Mcinturff, A.; Nehring, R.; Saladin, V.; Savord, T.; Sorrensen, G.; Smellie, R.; Tool, G.; Voy, D.

    1993-05-01

    The intent of the Accelerator System String Test (ASST) is to obtain data for model verification and information on the magnitudes of pressures and voltages encountered in an accelerator environment. The ASST milestone run was achieved during July and August, 1992 and consisted of demonstrating the accelerator components could be configured together as a system operating at full current. Following the milestone run, the string was warmed to counteract some design flaws that impeded the operational range. The string was again cooled to cryogenic temperatures in October, and a comprehensive power testing program was conducted through the end of January, 1993. This paper describes how the collider arc components operate in an accelerator environment during quenches induced by firing both strip heaters and spot heaters. Evaluation of the data illustrates how variations in the design parameters on magnets used in a string environment can impact system performance

  8. Development of laboratory acceleration test method for service life prediction of concrete structures

    International Nuclear Information System (INIS)

    Cho, M. S.; Song, Y. C.; Bang, K. S.; Lee, J. S.; Kim, D. K.

    1999-01-01

    Service life prediction of nuclear power plants depends on the application of history of structures, field inspection and test, the development of laboratory acceleration tests, their analysis method and predictive model. In this study, laboratory acceleration test method for service life prediction of concrete structures and application of experimental test results are introduced. This study is concerned with environmental condition of concrete structures and is to develop the acceleration test method for durability factors of concrete structures e.g. carbonation, sulfate attack, freeze-thaw cycles and shrinkage-expansion etc

  9. Radiation vulcanization of natural rubber latex with low energy accelerator-II

    Energy Technology Data Exchange (ETDEWEB)

    Haque, Md. Emdadul; Makuuchi, Keizo; Ikeda, Kenichi; Yoshii, Fumio; Kume, Tamikazu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Mitomo, Hiroshi [Gunma Univ., Faculty of Engineering, Dept. of Biological and Chemical Engineering, Kiryu, Gunma (Japan)

    2002-03-01

    The natural rubber latex (NRL) was radiation vulcanized under a low energy electron accelerator. Accelerating voltage and maximum beam current of this accelerator are 250 kV and 10 mA respectively. Irradiation was carried out in a reaction vessel with constant stirring. The capacity of the vessel is 18 liters. Radiation vulcanization accelerators (RVA) were normal butyl acrylate (n-BA) and nonane-diol-diacrylate (NDDA). NDDA has no bad smell like that of n-BA. 20 minutes irradiation time is enough to vulcanize 14 liters of latex when 5 phr RVA (both types) are used. Maximum of {approx}30 MPa tensile strength was obtained with 5 phr NDD-A. However the remained NDDA is difficult to remove due to high molecular weight. Water-extractable proteins content was determined in dipped films for various leaching conditions without and with additive (polyvinyl alcohol, PVA). Water extractable proteins content is reduced to {<=} 41 by adding 5 phr PVA and leaching for 8 hours. The tackiness of the dipped films is reduced to 0.1 from 9 gf by mixing 6 phr PVA with the irradiated latex. Hand gloves (surgical and examination) were successfully produced from the irradiated latex. (author)

  10. Pesticide leaching through sandy and loamy fields - long-term lessons learnt from the Danish Pesticide Leaching Assessment Programme.

    Science.gov (United States)

    Rosenbom, Annette E; Olsen, Preben; Plauborg, Finn; Grant, Ruth; Juhler, René K; Brüsch, Walter; Kjær, Jeanne

    2015-06-01

    The European Union authorization procedure for pesticides includes an assessment of the leaching risk posed by pesticides and their degradation products (DP) with the aim of avoiding any unacceptable influence on groundwater. Twelve-year's results of the Danish Pesticide Leaching Assessment Programme reveal shortcomings to the procedure by having assessed leaching into groundwater of 43 pesticides applied in accordance with current regulations on agricultural fields, and 47 of their DP. Three types of leaching scenario were not fully captured by the procedure: long-term leaching of DP of pesticides applied on potato crops cultivated in sand, leaching of strongly sorbing pesticides after autumn application on loam, and leaching of various pesticides and their DP following early summer application on loam. Rapid preferential transport that bypasses the retardation of the plow layer primarily in autumn, but also during early summer, seems to dominate leaching in a number of those scenarios. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Leaching of radioactive waste forms under saturated and unsaturated flow conditions

    International Nuclear Information System (INIS)

    Petelka, M.F.

    1987-01-01

    To predict the environmental impact of shallow land burial sites for radioactive waste, the mobilization and migration of waste nuclides must be estimated. The theoretical understanding that in potential leaching mechanisms leach-rate variations may arise from changes in both moisture content and volumetric flow rate was tested in column flow leach experiments using labeled vermiculite particles as a simulated waste form. As far as possible, conditions of flow rate and solution ion concentration were chosen to roughly approximate expected field conditions. A modified pressure-plate apparatus was developed, tested, and found suitable for the production of steady-state unsaturated conditions with leachate flow. Water content was determined using the gamma-ray attenuation method. The effects of several parameters on leaching were studied, including moisture content and pore velocity. Pore velocity effects were found to be negligible. It was found that the leach rate depends on the fraction of the exposed waste surface that is wetted and varies with the mobile water content in a non-linear fashion. The experimental results indicate that the release rate of radionuclides placed within a properly sited low-level waste disposal site may be two to three times smaller than that predicted assuming saturated conditions. This study was performed using a homogeneous fine-grained synthetic waste form, at room temperature, with a near neutral pH leachant and oxidizing conditions

  12. The Danish Pesticide Leaching Assessment Programme

    DEFF Research Database (Denmark)

    Rosenbom, Annette Elisabeth; Brüsch, Walter Michael; Juhler, Rene K.

    In 1998, the Danish Parliament initiated the Pesticide Leaching Assessment Programme (PLAP), an intensive monitoring programme aimed at evaluating the leaching risk of pesticides under field conditions. The objective of the PLAP is to improve the scientific foundation for decision......-making in the Danish regulation of pesticides. The specific aim is to analyse whether pesticides applied in accordance with current regulations leach to groundwater in unacceptable concentrations. The programme currently evaluates the leaching risk of 41 pesticides and 40 degradation products at five agricultural......, thiamethoxam, tribenuronmethyl, and triasulfuron) did not leach during the 1999-2009 monitoring period. 13 of the applied pesticides exhibited pronounced leaching of the pesticide and/or their degradation product(-s) 1 m b.g.s. in yearly average concentrations exceeding 0.1 μg/l (maximum allowable...

  13. Solutions for acceleration measurement in vehicle crash tests

    Science.gov (United States)

    Dima, D. S.; Covaciu, D.

    2017-10-01

    Crash tests are useful for validating computer simulations of road traffic accidents. One of the most important parameters measured is the acceleration. The evolution of acceleration versus time, during a crash test, form a crash pulse. The correctness of the crash pulse determination depends on the data acquisition system used. Recommendations regarding the instrumentation for impact tests are given in standards, which are focused on the use of accelerometers as impact sensors. The goal of this paper is to present the device and software developed by authors for data acquisition and processing. The system includes two accelerometers with different input ranges, a processing unit based on a 32-bit microcontroller and a data logging unit with SD card. Data collected on card, as text files, is processed with a dedicated software running on personal computers. The processing is based on diagrams and includes the digital filters recommended in standards.

  14. Application of percolation leaching in Fuzhou uranium mine

    International Nuclear Information System (INIS)

    Jiang Lang; Wang Haita; He Jiangming

    2006-01-01

    In order to solve these problems such as high cost by conventional agitation leaching, low permeability and low leaching rate by heap leach, a percolation leaching method was developed. Two-year's production results show that leaching rate of uranium is up to 90% by this method. Compared with conventional agitation leaching, the power, sulfuric acid and lime consumption by the percolation leaching decreased by 60%, 27% and 77% respectively. (authors)

  15. Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts

    International Nuclear Information System (INIS)

    Park, Sang Soon; Lee, Min Woo

    2014-01-01

    Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were investigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition

  16. Effect of the leaching of calcium hydroxide from cement paste on mechanical and physical properties

    International Nuclear Information System (INIS)

    Carde, C.; Francois, R.

    1997-01-01

    This paper deals with the effect of the leaching process of cement based materials on their mechanical and physical properties. In order to characterize this effect, the authors have performed experiments on cement paste samples. The leaching process was achieved by the use of a 50% concentrate solution of ammonium nitrate. Both compression tests and water porosity tests were conducted on micro-cylinder samples (10, 12, 14 and 20 mm of diameter) because of the slow kinetics of degradation due to the leaching. The deterioration of the cement paste and the mortar exposed to the action of the ammonium nitrate was manifested by a peripheral zone of less resistance. This process induces mainly a total leaching of Ca(OH) 2 and a progressive decalcification of C-S-H which leads to a gradient of C/S ratio in the leaching zone. Both mechanical tests and water porosity tests show that there is a linear variation of the loss of strength and the increase in porosity in relation to the ratio of degraded area over total area of the sample A d /A t . It means that both compressive resistance and water porosity of the leaching zone are constant whatever the size of the degraded zone and then whatever the time of exposure to the chemical attack. So the authors could venture the hypothesis that the dissolution of calcium hydroxide is the essential parameter governing both decrease in strength and increase in porosity

  17. Comparison of leaching characteristics of heavy metals from bottom and fly ashes in Korea and Japan.

    Science.gov (United States)

    Shim, Young-Sook; Rhee, Seung-Whee; Lee, Woo-Keun

    2005-01-01

    The objective of this research was to compare the leaching characteristics of heavy metals such as cadmium, chromium, copper, nickel, lead, etc., in Korean and Japanese municipal solid waste incineration (MSWI) ash. The rate of leaching of heavy metal was measured by KSLT and JTL-13, and the amount of heavy metals leached was compared with the metal content in each waste component. Finally, bio-availability testing was performed to assess the risks associated with heavy metals leached from bottom ash and fly ash. From the results, the value of neutralization ability in Japanese fly ash was four times higher than that in Korean fly ash. The reason was the difference in the content of Ca(OH)(2) in fly ash. The amount of lead leached exceeded the regulatory level in both Japanese and Korean fly ash. The rate of leaching was relatively low in ash with a pH in the range of 6-10. The bio-availability test in fly ash demonstrated that the amount of heavy metals leached was Pb>Cd>Cr, but the order was changed to Pb>Cr>Cd in the bottom ash. The leaching concentration of lead exceeded the Japanese risk level in all fly ashes from the two countries, but the leaching concentration of cadmium exceeded the regulatory level in Korean fly ash only.

  18. Comparison of leaching characteristics of heavy metals from bottom and fly ashes in Korea and Japan

    International Nuclear Information System (INIS)

    Shim, Young-Sook; Rhee, Seung-Whee; Lee, Woo-Keun

    2005-01-01

    The objective of this research was to compare the leaching characteristics of heavy metals such as cadmium, chromium, copper, nickel, lead, etc., in Korean and Japanese municipal solid waste incineration (MSWI) ash. The rate of leaching of heavy metal was measured by KSLT and JTL-13, and the amount of heavy metals leached was compared with the metal content in each waste component. Finally, bio-availability testing was performed to assess the risks associated with heavy metals leached from bottom ash and fly ash. From the results, the value of neutralization ability in Japanese fly ash was four times higher than that in Korean fly ash. The reason was the difference in the content of Ca(OH) 2 in fly ash. The amount of lead leached exceeded the regulatory level in both Japanese and Korean fly ash. The rate of leaching was relatively low in ash with a pH in the range of 6-10. The bio-availability test in fly ash demonstrated that the amount of heavy metals leached was Pb > Cd > Cr, but the order was changed to Pb > Cr > Cd in the bottom ash. The leaching concentration of lead exceeded the Japanese risk level in all fly ashes from the two countries, but the leaching concentration of cadmium exceeded the regulatory level in Korean fly ash only

  19. Studies on the mechanism for in-place leaching of fragmented uranium ore by blasting

    International Nuclear Information System (INIS)

    Wu Hengshan; Wang Changhan

    2001-01-01

    The report is based on the locale test studies at No.745 Mine and Baifang Copper (Uranium) Mine. According to hydrokinetics of porous medium. The character of mining methods of in-place leaching of fragmented uranium are, the best application conditions, in-place leaching theory, the fittest composite of fragments of crashing uranium ore, the lowest velocity of flow in solution liquid, the reasonable parameter of stop structure, the technology of leaching, meaning, the equation of solution liquid, the name of solution mining and its classification are studied. Especially some creation in the theory of leaching in mud ore and the technology of strengthened leaching are given. It would be helpful to the design and production

  20. Effect of Antifoam Agent on Oxidative Leaching of Hanford Tank Sludge Simulants

    International Nuclear Information System (INIS)

    Rapko, Brian M.; Jones, Susan A.; Lumetta, Gregg J.; Peterson, Reid A.

    2010-01-01

    Oxidative leaching of simulant tank waste containing an antifoam agent (AFA) to reduce the chromium content of the sludge was tested using permanganate as the oxidant in 0.25 M NaOH solutions. AFA is added to the waste treatment process to prevent foaming. The AFA, Dow Corning Q2-3183A, is a surface-active polymer that consists of polypropylene glycol, polydimethylsiloxane, octylphenoxy polyethoxy ethanol, treated silica, and polyether polyol. Some of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) waste slurries contain high concentrations of undissolved solids that would exhibit undesirable behavior without AFA addition. These tests were conducted to determine the effect of the AFA on oxidative leaching of Cr(III) in waste by permanganate. It has not previously been determined what effect AFA has on the permanganate reaction. This study was conducted to determine the effect AFA has on the oxidation of the chromium, plus plutonium and other criticality-related elements, specifically Fe, Ni and Mn. During the oxidative leaching process, Mn is added as liquid permanganate solution and is converted to an insoluble solid that precipitates as MnO2 and becomes part of the solid waste. Caustic leaching was performed followed by an oxidative leach at either 25 C or 45 C. Samples of the leachate and solids were collected at each step of the process. Initially, Battelle-Pacific Northwest Division (PNWD) was contracted by Bechtel National, Inc. to perform these further scoping studies on oxidative alkaline leaching. The data obtained from the testing will be used by the WTP operations to develop procedures for permanganate dosing of Hanford tank sludge solids during oxidative leaching. Work was initially conducted under contract number 24590-101-TSA-W000-00004. In February 2007, the contract mechanism was switched to Pacific Northwest National Laboratory (PNNL) operating Contract DE-AC05-76RL01830. In summary, this report describes work focused on determining

  1. Effect of Antifoam Agent on Oxidative Leaching of Hanford Tank Sludge Simulants

    Energy Technology Data Exchange (ETDEWEB)

    Rapko, Brian M.; Jones, Susan A.; Lumetta, Gregg J.; Peterson, Reid A.

    2010-02-26

    Oxidative leaching of simulant tank waste containing an antifoam agent (AFA) to reduce the chromium content of the sludge was tested using permanganate as the oxidant in 0.25 M NaOH solutions. AFA is added to the waste treatment process to prevent foaming. The AFA, Dow Corning Q2-3183A, is a surface-active polymer that consists of polypropylene glycol, polydimethylsiloxane, octylphenoxy polyethoxy ethanol, treated silica, and polyether polyol. Some of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) waste slurries contain high concentrations of undissolved solids that would exhibit undesirable behavior without AFA addition. These tests were conducted to determine the effect of the AFA on oxidative leaching of Cr(III) in waste by permanganate. It has not previously been determined what effect AFA has on the permanganate reaction. This study was conducted to determine the effect AFA has on the oxidation of the chromium, plus plutonium and other criticality-related elements, specifically Fe, Ni and Mn. During the oxidative leaching process, Mn is added as liquid permanganate solution and is converted to an insoluble solid that precipitates as MnO2 and becomes part of the solid waste. Caustic leaching was performed followed by an oxidative leach at either 25°C or 45°C. Samples of the leachate and solids were collected at each step of the process. Initially, Battelle-Pacific Northwest Division (PNWD) was contracted by Bechtel National, Inc. to perform these further scoping studies on oxidative alkaline leaching. The data obtained from the testing will be used by the WTP operations to develop procedures for permanganate dosing of Hanford tank sludge solids during oxidative leaching. Work was initially conducted under contract number 24590-101-TSA-W000-00004. In February 2007, the contract mechanism was switched to Pacific Northwest National Laboratory (PNNL) operating Contract DE-AC05-76RL01830. In summary, this report describes work focused on

  2. Basic and acidic leaching of Melton Valley Storage Tank sludge at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Collins, J.L.; Egan, B.Z.; Beahm, E.C.

    1995-01-01

    Basic and acidic leaching tests were conducted with samples of sludge taken from an underground storage tank at the US Department of Energy Melton Valley Storage Tank facility at Oak Ridge National Laboratory. The tests evaluated separation technologies for use in sludge processing to concentrate the radionuclides and reduce the volumes of storage tank waste for final disposal. Study results of sludge characterization, caustic leaching of sludge samples at ambient temperature and at 95 degrees C, and acid leaching of sludge samples at ambient temperature are reported in detail

  3. Assessment of long-term leaching from waste incineration air-pollution-control residues

    DEFF Research Database (Denmark)

    Astrup, Thomas; Mosbæk, Hans; Christensen, Thomas Højlund

    2006-01-01

    Assessment of long-term leaching from MSWI air-pollution-control (APC) residues is discussed with respect to use in environmental impact assessment, such as life-cycle assessment (LCA). A method was proposed for estimating leaching as a function of the liquid-to-solid (L/S) ratio in a long......-term perspective (L/S 5000l/kg). Data for changes in residue pH as a function of L/S was used in combination with pH dependent leaching data to predict leachate concentrations of Al, Ca, Cd, Ba, Mg, Ni, Pb, S, Pb, V and Zn as a function of L/S. Mass balance calculations were used to determine the element fractions...... leached with respect to L/S. The estimated long-term leaching from a semi-dry residue and a fly ash was compared with short-term leaching determined by batch tests at L/S 10l/kg, both carbonated and non-carbonated versions of the residues were investigated. Generally, very high L/S ratios above 2000l...

  4. Groundwater leaching of neutralized and untreated acid-leached uranium-mill tailings

    International Nuclear Information System (INIS)

    Gee, G.W.; Begej, C.W.; Campbell, A.C.; Sauter, N.N.; Opitz, B.E.; Sherwood, D.R.

    1981-01-01

    Tailings neutralization was examined to determine the effect of neutralization on contaminant release. Column leaching of acid extracted uranium mill tailings from Exxon Highland Mill, Wyoming, Pathfinder Gas Hills Mill, Wyoming, and the Dawn Midnite Mill, Washington, resulted in the flushing of high concentrations of salts in the first four pore volumes of leachate, followed by a steady decrease to the original groundwater salt concentrations. Neutralization decreased the concentration of salts and radionuclides leaching from the tailings and decreased the volume of solution required to return the solution to the groundwater pH and EC. Radium-226 and uranium-238 leached quickly from the tailings in the initial pore volumes of both neutralized and unneutralized tailings, and then decreased significantly. 6 figures, 5 tables

  5. Pressure leaching of chalcopyrite concentrate

    Science.gov (United States)

    Aleksei, Kritskii; Kirill, Karimov; Stanislav, Naboichenko

    2018-05-01

    The results of chalcopyrite concentrate processing using low-temperature and high-temperature sulfuric acid pressure leaching are presented. A material of the following composition was used, 21.5 Cu, 0.1 Zn, 0.05 Pb, 0.04 Ni, 26.59 S, 24.52 Fe, 16.28 SiO2 (in wt.%). The influence of technological parameters on the degree of copper and iron extraction into the leach solution was studied in the wide range of values. The following conditions were suggested as the optimal for the high-temperature pressure leaching: t = 190 °C, PO2 = 0.5 MPa, CH2SO4 = 15 g/L, L:S = 6:1. At the mentioned parameters, it is possible to extract at least 98% Cu from concentrate into the leaching solution during 100 minutes. The following conditions were suggested as optimal for the low-temperature pressure leaching: t = 105 °C, PO2 = 1.3-1.5 MPa, CH2SO4 = 90 g/L, L:S = 10:1. At the mentioned parameters, it is possible to extract up to 83% Cu from the concentrate into the leach solution during 300-360 minutes.

  6. Workshop on the leaching mechanisms of nuclear-waste forms, October 27-28, 1981. Summary report

    International Nuclear Information System (INIS)

    Mendel, J.E.

    1982-04-01

    The purpose of this informal workshop was to initiate the program and achieve the following goals: (1) acquaint laboratory investigators (data generators) with the needs of the mathematical modelers (data users). Session I was devoted to a tutorial by D.D. Jackson, mathematical modeler for the leaching mechanisms program, on PROTOCOL, a general case waste form leaching model; (2) define important testing parameters, based on the present state of knowledge. To achieve this, a number of important testing parameters were identified for special discussion in Session II; (3) develop an understanding of the interrelationships between the activities of leaching mechanisms program participants, and begin definition of the specific role of each participant in the overall program; and (4) establish good communication between the leaching mechanisms program and related programs, particularly the waste form leaching program at the Savannah River Laboratory (SRL) and the various Nuclear Waste Terminal Storage (NWTS) waste package programs. The agenda for the workshop is attached as Appendix A; a list of attendees is in Appendix B. Because this workshop was devoted to preliminary planning for the leaching mechanisms program, the presentations and discussions were purposely kept informal. This report represents a synopsis of the proceedings that has been prepared by the leaching mechanisms coordinator and reviewed by the workshop participants

  7. Pilot instrumentation of a Superpave test section at the Kansas Accelerated Testing laboratory

    Science.gov (United States)

    2003-04-01

    Two Superpave test sections were constructed at the Kansas Accelerated Testing Laboratory (K-ATL) with 12.5 mm (2 in) nominal maximum size Superpave mixture (SM-2A) with varying percentages (15 and 30 percent) of river sand. A 150 kN (34 kip) tandem ...

  8. Situ leaching uranium mining conditions of the pilot phase of the safety management

    International Nuclear Information System (INIS)

    Liu Wenyuan

    2014-01-01

    With China's large, very large sandstone type uranium deposits have been discovered in the Ordos Basin, Inner Mongolia and its surrounding for uranium mining in the region has been carried out. Sandstone-type uranium mining, mainly used in China is 'to dip' and the technology is relatively mature. Situ leaching mining process, the deposit conditions Test conditions pilot phase, however, limited by cost control and field conditions, equipment shabby, out in the conditions of the pilot phase of security issues in the larger securityrisks. This will be Ordos ongoing test conditions situ leaching uranium mines, for example, raised situ leaching uranium mining conditions of the pilot phase a few safety measures recommended. (author)

  9. Accelerated Creep Testing of High Strength Aramid Webbing

    Science.gov (United States)

    Jones, Thomas C.; Doggett, William R.; Stnfield, Clarence E.; Valverde, Omar

    2012-01-01

    A series of preliminary accelerated creep tests were performed on four variants of 12K and 24K lbf rated Vectran webbing to help develop an accelerated creep test methodology and analysis capability for high strength aramid webbings. The variants included pristine, aged, folded and stitched samples. This class of webbings is used in the restraint layer of habitable, inflatable space structures, for which the lifetime properties are currently not well characterized. The Stepped Isothermal Method was used to accelerate the creep life of the webbings and a novel stereo photogrammetry system was used to measure the full-field strains. A custom MATLAB code is described, and used to reduce the strain data to produce master creep curves for the test samples. Initial results show good correlation between replicates; however, it is clear that a larger number of samples are needed to build confidence in the consistency of the results. It is noted that local fiber breaks affect the creep response in a similar manner to increasing the load, thus raising the creep rate and reducing the time to creep failure. The stitched webbings produced the highest variance between replicates, due to the combination of higher local stresses and thread-on-fiber damage. Large variability in the strength of the webbings is also shown to have an impact on the range of predicted creep life.

  10. Leaching behaviour of bottom ash from RDF high-temperature gasification plants

    International Nuclear Information System (INIS)

    Gori, M.; Pifferi, L.; Sirini, P.

    2011-01-01

    This study investigated the physical properties, the chemical composition and the leaching behaviour of two bottom ash (BA) samples from two different refuse derived fuel high-temperature gasification plants, as a function of particle size. The X-ray diffraction patterns showed that the materials contained large amounts of glass. This aspect was also confirmed by the results of availability and ANC leaching tests. Chemical composition indicated that Fe, Mn, Cu and Cr were the most abundant metals, with a slight enrichment in the finest fractions. Suitability of samples for inert waste landfilling and reuse was evaluated through the leaching test EN 12457-2. In one sample the concentration of all metals was below the limit set by law, while limits were exceeded for Cu, Cr and Ni in the other sample, where the finest fraction showed to give the main contribution to leaching of Cu and Ni. Preliminary results of physical and geotechnical characterisation indicated the suitability of vitrified BA for reuse in the field of civil engineering. The possible application of a size separation pre-treatment in order to improve the chemical characteristics of the materials was also discussed.

  11. Evaluation of long term leaching of borosilicate glasses

    International Nuclear Information System (INIS)

    Lanza, F.; Parnisari, E.

    1978-01-01

    For the evaluation of long term hazard of glass, data on long term glass leaching are needed. Moreover for long term leaching a model of homogeneous dissolution seems reasonable and ask for confirmation. Tests were performed at 30 0 , 80 0 , 100 0 , using an apparatus of the Soxhlet type, to 3.600 hours. Results were obtained as a weight loss and analysed following a relation with time composed by a parabolic and a linear part. Analysis of the surface layer using energy dispersion X ray spectrometry were performed. A critical analysis of the results and of the apparatus is presented

  12. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-01-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  13. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-05-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  14. Real-time and accelerated outdoor endurance testing of solar cells

    Science.gov (United States)

    Forestieri, A. F.; Anagnostou, E.

    1977-01-01

    Real-time and accelerated outdoor endurance testing was performed on a variety of samples of interest to the National Photovoltaic Conversion Program. The real-time tests were performed at seven different sites and the accelerated tests were performed at one of those sites in the southwestern United States. The purpose of the tests were to help evaluate the lifetime of photovoltaic systems. Three types of samples were tested; transmission samples of possible cover materials, sub-modules constructed using these materials attached to solar cells, and solar cell modules produced by the manufacturers for the ERDA program. Results indicate that suitable cover materials are glass, FEP-A and PFA. Dirt accumulation and cleanability are important factors in the selection of solar cell module covers and encapsulants.

  15. [Leaching characteristics of heavy metals and utilization of filter media in BAF].

    Science.gov (United States)

    Zou, Jin-long; Dai, Ying

    2007-10-01

    A series of leaching tests were conducted to study the solidification of heavy metals in biological filter media made with dried sludge as an additive. The maximum leaching contents of Cd, Cr, Cu and Pb are obtained when pH is 1; leaching contents of heavy metals have an obvious decrease as pH is greater than or equal to 3; and it can be concluded from the results that pH has a significant influence on the leaching characteristic of heavy metals at leaching time of either 24 h or 30 d. X-ray diffraction analysis performed on filter media reveal the main compounds of the 4 heavy metals are Pb2O(CrO4), CdSiO3 and CuO, and the heavy metals are solidified in the mesh structure of Si--O. Heavy metals (such as Cd, Cr, Cu and Pb) can be solidified in filter media through a series of crystalline phase changes and chemical reaction after high temperature sintering. The new filter media (obtained in test) were used in biological aerated filter (BAF) to treat wastewater (C/N about 11.5 and 25.5) in a simultaneous nitrification and denitrification (SND) system. Based on the mechanism of SND, the average removal efficienciesof NH4(+)-N and TN filled with the new filter media (obtained in test) are about 85.5%, 90.3%, 46.6% and 49.6%, respectively, and it is higher than those of other 3 medias (Jiangxi ceramsite, Guangzhou ceramsite and Shanxi activated carbon). The results provide a better understanding of factors that may affect the immobilization and leaching characteristics of heavy metals in ceramsite, which promotes the extensive use of filter media in BAF.

  16. Accelerated Testing with Multiple Failure Modes under Several Temperature Conditions

    OpenAIRE

    Zongyue Yu; Zhiqian Ren; Junyong Tao; Xun Chen

    2014-01-01

    A complicated device may have multiple failure modes, and some of the failure modes are sensitive to low temperatures. To assess the reliability of a product with multiple failure modes, this paper presents an accelerated testing in which both of the high temperatures and the low temperatures are applied. Firstly, an acceleration model based on the Arrhenius model but accounting for the influence of both the high temperatures and low temperatures is proposed. Accordingly, an accelerated testi...

  17. An accelerated test method of luminous flux depreciation for LED luminaires and lamps

    International Nuclear Information System (INIS)

    Qian, C.; Fan, X.J.; Fan, J.J.; Yuan, C.A.; Zhang, G.Q.

    2016-01-01

    Light Emitting Diode (LED) luminaires and lamps are energy-saving and environmental friendly alternatives to traditional lighting products. However, current luminous flux depreciation test at luminaire and lamp level requires a minimum of 6000 h testing, which is even longer than the product development cycle time. This paper develops an accelerated test method for luminous flux depreciation to reduce the test time within 2000 h at an elevated temperature. The method is based on lumen maintenance boundary curve, obtained from a collection of LED source lumen depreciation data, known as LM-80 data. The exponential decay model and Arrhenius acceleration relationship are used to determine the new threshold of lumen maintenance and acceleration factor. The proposed method has been verified by a number of simulation studies and experimental data for a wide range of LED luminaire and lamp types from both internal and external experiments. The qualification results obtained by the accelerated test method agree well with traditional 6000 h tests. - Highlights: • We develop an accelerated test method for LED luminaires and lamps. • The method is proposed based on a “Boundary Curve” concept. • The parameters of the boundary curve are extracted from LM-80 test reports. • Qualification results from the proposed method agree with ES requirements.

  18. Accelerated in vitro release testing method for naltrexone loaded PLGA microspheres.

    Science.gov (United States)

    Andhariya, Janki V; Choi, Stephanie; Wang, Yan; Zou, Yuan; Burgess, Diane J; Shen, Jie

    2017-03-30

    The objective of the present study was to develop a discriminatory and reproducible accelerated release testing method for naltrexone loaded parenteral polymeric microspheres. The commercially available naltrexone microsphere product (Vivitrol ® ) was used as the testing formulation in the in vitro release method development, and both sample-and-separate and USP apparatus 4 methods were investigated. Following an in vitro drug stability study, frequent media replacement and addition of anti-oxidant in the release medium were used to prevent degradation of naltrexone during release testing at "real-time" (37°C) and "accelerated" (45°C), respectively. The USP apparatus 4 method was more reproducible than the sample-and-separate method. In addition, the accelerated release profile obtained using USP apparatus 4 had a shortened release duration (within seven days), and good correlation with the "real-time" release profile. Lastly, the discriminatory ability of the developed accelerated release method was assessed using compositionally equivalent naltrexone microspheres with different release characteristics. The developed accelerated USP apparatus 4 release method was able to detect differences in the release characteristics of the prepared naltrexone microspheres. Moreover, a linear correlation was observed between the "real-time" and accelerated release profiles of all the formulations investigated, suggesting that the release mechanism(s) may be similar under both conditions. These results indicate that the developed accelerated USP apparatus 4 method has the potential to be an appropriate fast quality control tool for long-acting naltrexone PLGA microspheres. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Life cycle assessment and residue leaching: The importance of parameter, scenario and leaching data selection

    Energy Technology Data Exchange (ETDEWEB)

    Allegrini, E., E-mail: elia@env.dtu.dk [Technical University of Denmark, Department of Environmental Engineering, Building 115, 2800 Lyngby (Denmark); Butera, S. [Technical University of Denmark, Department of Environmental Engineering, Building 115, 2800 Lyngby (Denmark); Kosson, D.S. [Vanderbilt University, Department of Civil and Environmental Engineering, Box 1831 Station B, Nashville, TN 37235 (United States); Van Zomeren, A. [Energy Research Centre of the Netherlands (ECN), Department of Environmental Risk Assessment, P.O. Box 1, 1755 ZG Petten (Netherlands); Van der Sloot, H.A. [Hans van der Sloot Consultancy, Dorpsstraat 216, 1721 BV Langedijk (Netherlands); Astrup, T.F. [Technical University of Denmark, Department of Environmental Engineering, Building 115, 2800 Lyngby (Denmark)

    2015-04-15

    Highlights: • Relevance of metal leaching in waste management system LCAs was assessed. • Toxic impacts from leaching could not be disregarded. • Uncertainty of toxicity, due to background activities, determines LCA outcomes. • Parameters such as pH and L/S affect LCA results. • Data modelling consistency and coverage within an LCA are crucial. - Abstract: Residues from industrial processes and waste management systems (WMSs) have been increasingly reutilised, leading to landfilling rate reductions and the optimisation of mineral resource utilisation in society. Life cycle assessment (LCA) is a holistic methodology allowing for the analysis of systems and products and can be applied to waste management systems to identify environmental benefits and critical aspects thereof. From an LCA perspective, residue utilisation provides benefits such as avoiding the production and depletion of primary materials, but it can lead to environmental burdens, due to the potential leaching of toxic substances. In waste LCA studies where residue utilisation is included, leaching has generally been neglected. In this study, municipal solid waste incineration bottom ash (MSWI BA) was used as a case study into three LCA scenarios having different system boundaries. The importance of data quality and parameter selection in the overall LCA results was evaluated, and an innovative method to assess metal transport into the environment was applied, in order to determine emissions to the soil and water compartments for use in an LCA. It was found that toxic impacts as a result of leaching were dominant in systems including only MSWI BA utilisation, while leaching appeared negligible in larger scenarios including the entire waste system. However, leaching could not be disregarded a priori, due to large uncertainties characterising other activities in the scenario (e.g. electricity production). Based on the analysis of relevant parameters relative to leaching, and on general results

  20. Heap leaching procedure for the Uranium extraction

    International Nuclear Information System (INIS)

    Shishahbore, M. R.

    2002-01-01

    Heap leaching of Uranium ores is currently in use in several countries. Before taking any decision for construction of heap in industrial scale, it is necessary to obtain the main factors that influence the heap leaching process, such as acid construction, acid solution flowrate, temperature of reaction, or size, ration of liquid to solid, permeability and suitable oxidant. To achieve the above parameters, small scale column leaching is usually recommended. In this project column leaching were carried out in 6 plexiglass column with 43.5 cm an height and 7.4 cm inner diameter. In each column closely 2.00 kg Uranium ore were leached by sulfuric acid. Leaching operation on Iranian ores from two different anomalies from the same area were investigated. In this project, six column were leached at different flowrate of eluent and effect of oxidant were investigated. Acid consumption were in the range of 60 - 144 kg per ton ore and recovery between 73.07% - 99.97%. Finally according to the results obtained, investigated that over are suitable to heap leaching technique. Al tough, to enforce of heap leaching project need to more experiments

  1. Advanced Accelerated Power Cycling Test for Reliability Investigation of Power Device Modules

    DEFF Research Database (Denmark)

    Choi, Uimin; Jørgensen, Søren; Blaabjerg, Frede

    2016-01-01

    This paper presents an apparatus and methodology for an advanced accelerated power cycling test of insulated-gate bipolar transistor (IGBT) modules. In this test, the accelerated power cycling test can be performed under more realistic electrical operating conditions with online wear-out monitoring...... of tested power IGBT module. The various realistic electrical operating conditions close to real three-phase converter applications can be achieved by the simple control method. Further, by the proposed concept of applying the temperature stress, it is possible to apply various magnitudes of temperature...... swing in a short cycle period and to change the temperature cycle period easily. Thanks to a short temperature cycle period, test results can be obtained in a reasonable test time. A detailed explanation of apparatus such as configuration and control methods for the different functions of accelerated...

  2. Compact X-ray source at STF (Super Conducting Accelerator Test Facility)

    International Nuclear Information System (INIS)

    Urakawa, J

    2012-01-01

    KEK-STF is a super conducting linear accelerator test facility for developing accelerator technologies for the ILC (International Linear Collider). We are supported in developing advanced accelerator technologies using STF by Japanese Ministry (MEXT) for Compact high brightness X-ray source development. Since we are required to demonstrate the generation of high brightness X-ray based on inverse Compton scattering using super conducting linear accelerator and laser storage cavity technologies by October of next year (2012), the design has been fixed and the installation of accelerator components is under way. The necessary technology developments and the planned experiment are explained.

  3. Effect of different glass and zeolite A compositions on the leach resistance of ceramic waste forms

    International Nuclear Information System (INIS)

    Lewis, M.A.; Hash, M.; Glandorf, D.

    1996-01-01

    A ceramic waste form is being developed for waste generated during electrometallurgical treatment of spent nuclear fuel. The waste is generated when fission products are removed from the electrolyte, LiCl-KCl eutectic. The waste form is a composite fabricated by hot isostatic pressing a mixture of glass frit and zeolite occluded with fission products and salt. Normalized release rate is less than 1 g/m 2 d for all elements in MCC-1 leach test run for 28 days in deionized water at 90 C. This leach resistance is comparable to that of early Savannah River glasses. We are investigating how leach resistance is affected by changes in cationic form of zeolite and in glass composition. Composites were made with 3 forms of zeolite A and 6 glasses. We used 3-day ASTM C1220-92 (formerly MCC-1) leach tests to screen samples for development purposes only. The leach test results show that the glass composites of zeolites 5A and 4A retain fission products equally well. Loss of Cs is small (0.1-0.5 wt%), while the loss of divalent and trivalent fission products is one or more orders of magnitude smaller. Composites of 5A retain chloride ion better in these short-term screens than 4A and 3A. The more leach resistant composites were made with durable glasses rich in silica and poor in alkaline earth oxides. XRD show that a salt phase was absent in the leach resistant composites of 5A and the better glasses but was present in the other composites with poorer leach performance. Thus, absence of salt phase corresponds to improved leach resistance. Interactions between zeolite and glass depend on composition of both

  4. Pesticide leaching through sandy and loamy fields – Long-term lessons learnt from the Danish Pesticide Leaching Assessment Programme

    International Nuclear Information System (INIS)

    Rosenbom, Annette E.; Olsen, Preben; Plauborg, Finn; Grant, Ruth; Juhler, René K.; Brüsch, Walter; Kjær, Jeanne

    2015-01-01

    The European Union authorization procedure for pesticides includes an assessment of the leaching risk posed by pesticides and their degradation products (DP) with the aim of avoiding any unacceptable influence on groundwater. Twelve-year's results of the Danish Pesticide Leaching Assessment Programme reveal shortcomings to the procedure by having assessed leaching into groundwater of 43 pesticides applied in accordance with current regulations on agricultural fields, and 47 of their DP. Three types of leaching scenario were not fully captured by the procedure: long-term leaching of DP of pesticides applied on potato crops cultivated in sand, leaching of strongly sorbing pesticides after autumn application on loam, and leaching of various pesticides and their DP following early summer application on loam. Rapid preferential transport that bypasses the retardation of the plow layer primarily in autumn, but also during early summer, seems to dominate leaching in a number of those scenarios. - Highlights: • Field-results reveal shortcomings in the EU authorization procedure for pesticides. • The plough layer can be bypassed via preferential transport in e.g. wormholes. • Pesticides properties are decisive for leaching pattern on the sandy fields. • The hydrogeological settings control the leaching patterns on the loamy fields. • Pesticide detection frequency seems to be independent of the month of the year. - Long-term lessons learnt from the Danish Pesticide Leaching Assessment Programme reveals shortcomings in the European Union authorization procedure for pesticides

  5. Using Uncertainty Analysis to Guide the Development of Accelerated Stress Tests (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kempe, M.

    2014-03-01

    Extrapolation of accelerated testing to the long-term results expected in the field has uncertainty associated with the acceleration factors and the range of possible stresses in the field. When multiple stresses (such as temperature and humidity) can be used to increase the acceleration, the uncertainty may be reduced according to which stress factors are used to accelerate the degradation.

  6. Process for controlling calcium in a leach operation

    International Nuclear Information System (INIS)

    Habib, E.J.

    1982-01-01

    A method for controlling calcium, e.g. calcite, build-up in the leach solution of a uranium and/or related values recovery operation wherein the leach solution is flowed through a value bearing ore to dissolve the desired values. A soluble fluoride, e.g. sodium fluoride, is added to the leach solution after it has passed through the ore to thereby precipitate calcium fluoride from the leach solution and lower the calcium content of the leach solution. The soluble fluoride may be added to the leach solution before the leach solution passes through the process equipment which is used to remove the values from the leach solution or the soluble fluoride may be added after the leach solution passes through the process equipment. If added before, it is preferable to also add a carbonate/bicarbonate solution along with the soluble fluoride to prevent coprecipitation of uranyl/desired value fluoride or to redissolve coprecipitated fluoride back into the leach solution

  7. Design of Accelerated Reliability Test for CNC Motorized Spindle Based on Vibration Signal

    Directory of Open Access Journals (Sweden)

    Chen Chao

    2016-01-01

    Full Text Available Motorized spindle is the key functional component of CNC machining centers which is a mechatronics system with long life and high reliability. The reliability test cycle of motorized spindle is too long and infeasible. This paper proposes a new accelerated test for reliability evaluation of motorized spindle. By field reliability test, authors collect and calculate the load data including rotational speed, cutting force and torque. Load spectrum distribution law is analyzed. And authors design a test platform to apply the load spectrum. A new method to define the fuzzy acceleration factor based on the vibration signal is proposed. Then the whole test plan of accelerated reliability test is done.

  8. RF pulse compression in the NLC test accelerator at SLAC

    International Nuclear Information System (INIS)

    Lavine, T.L.

    1995-01-01

    At the Stanford Linear Accelerator Center (SLAC), the authors are designing a Next Linear Collider (NLC) with linacs powered by X-band klystrons with rf pulse compression. The design of the linac rf system is based on X-band prototypes which have been tested at high power, and on a systems-integration test - the Next Linear Collider Test Accelerator (NLCTA) - which is currently under construction at SLAC. This paper discusses some of the systems implications of rf pulse compression, and the use of pulse compression in the NLCTA, both for peak power multiplication and for controlling, by rf phase modulation, intra-pulse variations in the linac beam energy

  9. Nanosized zero-valent iron as Fenton-like reagent for ultrasonic-assisted leaching of zinc from blast furnace sludge

    Energy Technology Data Exchange (ETDEWEB)

    Mikhailov, Ivan, E-mail: ivan.mikhailov@misis.ru [National University of Science and Technology “MISiS”, 4 Leninskiy prospekt, Moscow, 119049 (Russian Federation); Komarov, Sergey [Tohoku University, 6-6-02 Aramaki Aza Aoba, Aoba-ku, Sendai, 980-8576 (Japan); Levina, Vera; Gusev, Alexander; Issi, Jean-Paul; Kuznetsov, Denis [National University of Science and Technology “MISiS”, 4 Leninskiy prospekt, Moscow, 119049 (Russian Federation)

    2017-01-05

    Highlights: • nZVI is used as Fenton-like reagent for activation of Zn leaching from the BFS. • nZVI has positive effect on kinetics of Zn leaching though with some loss of efficiency. • A complex ultrasonic-assisted method for BFS recycling is proposed. - Abstract: Ultrasonic-assisted sulphuric acid leaching combined with a Fenton-like process, utilizing nanoscale zero-valent iron (nZVI), was investigated to enhance the leaching of zinc from the blast furnace sludge (BFS). The leaching of iron (Fe) and zinc (Zn) from the sludge was investigated using Milli-Q water/BFS ratio of 10 and varying the concentration of hydrogen peroxide, sulphuric acid, the temperature, the input energy for ultrasound irradiation, and the presence or absence of nZVI as a Fenton reagent. The results showed that with 1 g/l addition of nZVI and 0.05 M of hydrogen peroxide, the kinetic rate of Zn leaching increased with a maximum dissolution degree of 80.2%, after 5 min treatment. In the absence of nZVI, the maximum dissolution degree of Zn was 99.2%, after 15 min treatment with 0.1 M of hydrogen peroxide. The rate of Zn leaching at several concentrations of hydrogen peroxide is accelerated in the presence of nZVI although a reduction in efficiency was observed. The loss of Fe was no more than 3%. On the basis of these results, the possible route for BFS recycling has been proposed (BFS slurry mixed with sulphuric acid and hydrogen peroxide is recirculated under ultrasonic irradiation then separated).

  10. Influence of several experimental parameters on As and Se leaching from coal fly ash samples

    International Nuclear Information System (INIS)

    Otero-Rey, Jose R.; Mato-Fernandez, Maria J.; Moreda-Pineiro, Jorge; Alonso-Rodriguez, Elia; Muniategui-Lorenzo, Soledad; Lopez-Mahia, Purificacion; Prada-Rodriguez, Dario

    2005-01-01

    Coal fly ash leaching process for As and Se is studied. Environmental parameters such as pH, temperature, solid-liquid ratio, particle size and leaching time are taken into account in order to simulate As and Se leaching process for disposal coal fly ash. Analysis of reference materials was carried out by using of hydride generation coupled to atomic fluorescence spectrometry. Plackett-Burman experimental design is used to know the significative parameters, and Box-Behnken experimental design is used to refine the results obtained for these significative parameters. pH and temperature shown a hardly influence in leaching process. Furthermore, leaching time was also significative. According our results, it may be assumed that percentage of As and Se leaching in experimental conditions tested is relatively low for acidic fly ashes

  11. Accelerated Testing of Polymeric Composites Using the Dynamic Mechanical Analyzer

    Science.gov (United States)

    Abdel-Magid, Becky M.; Gates, Thomas S.

    2000-01-01

    Creep properties of IM7/K3B composite material were obtained using three accelerated test methods at elevated temperatures. Results of flexural creep tests using the dynamic mechanical analyzer (DMA) were compared with results of conventional tensile and compression creep tests. The procedures of the three test methods are described and the results are presented. Despite minor differences in the time shift factor of the creep compliance curves, the DMA results compared favorably with the results from the tensile and compressive creep tests. Some insight is given into establishing correlations between creep compliance in flexure and creep compliance in tension and compression. It is shown that with careful consideration of the limitations of flexure creep, a viable and reliable accelerated test procedure can be developed using the DMA to obtain the viscoelastic properties of composites in extreme environments.

  12. Verification of mechanistic-empirical design models for flexible pavements through accelerated pavement testing.

    Science.gov (United States)

    2014-08-01

    The Midwest States Accelerated Pavement Testing Pooled Fund Program, financed by the highway : departments of Kansas, Iowa, and Missouri, has supported an accelerated pavement testing (APT) project to : validate several models incorporated in the NCH...

  13. Investigations on microbial leaching of zircon by means of spark source mass spectrometry

    International Nuclear Information System (INIS)

    Becker, S.; Dietze, H.J.; Bullmann, M.; Iske, U.

    1985-01-01

    Spark source mass spectrometry is a useful method for chemical element analysis of geological and biological samples. This sensitive technique (detection limit down to the ppb-range) is used to analyze leaching processes by means of several microorganisms. The problem of microbial leaching of chemical resistent materials was tested under laboratory condition with regard to possible analytical and technical applications. Leaching of metalls with chemolithotrophic and heterotrophic, organic acids producing microorganisms has been investigated with zircon from Baltic Shield containing 0.7% rare earth elements and 1.67% hafnium. When zircon is leached with strains of Thiobacillus ferroxidans the rare earth elements, Hf, Th, and U mostly (about 80%) can be recovered. (author)

  14. Accelerated testing of space mechanisms

    Science.gov (United States)

    Murray, S. Frank; Heshmat, Hooshang

    1995-01-01

    This report contains a review of various existing life prediction techniques used for a wide range of space mechanisms. Life prediction techniques utilized in other non-space fields such as turbine engine design are also reviewed for applicability to many space mechanism issues. The development of new concepts on how various tribological processes are involved in the life of the complex mechanisms used for space applications are examined. A 'roadmap' for the complete implementation of a tribological prediction approach for complex mechanical systems including standard procedures for test planning, analytical models for life prediction and experimental verification of the life prediction and accelerated testing techniques are discussed. A plan is presented to demonstrate a method for predicting the life and/or performance of a selected space mechanism mechanical component.

  15. Characterization of phosphorus leaching from phosphate waste rock in the Xiangxi River watershed, Three Gorges Reservoir, China.

    Science.gov (United States)

    Jiang, Li-Guo; Liang, Bing; Xue, Qiang; Yin, Cheng-Wei

    2016-05-01

    Phosphate mining waste rocks dumped in the Xiangxi River (XXR) bay, which is the largest backwater zone of the Three Gorges Reservoir (TGR), are treated as Type I industry solid wastes by the Chinese government. To evaluate the potential pollution risk of phosphorus leaching from phosphate waste rocks, the phosphorus leaching behaviors of six phosphate waste rock samples with different weathering degrees under both neutral and acidic conditions were investigated using a series of column leaching experiments, following the Method 1314 standard of the US EPA. The results indicate that the phosphorus release mechanism is solubility-controlled. Phosphorus release from waste rocks increases as pH decreases. The phosphorus leaching concentration and cumulative phosphorus released in acidic leaching conditions were found to be one order of magnitude greater than that in neutral leaching conditions. In addition, the phosphorus was released faster during the period when environmental pH turned from weak alkalinity to slight acidity, with this accelerated release period appearing when L/S was in the range of 0.5-2.0 mL/g. In both neutral and acidic conditions, the average values of Total Phosphorus (TP), including orthophosphates, polyphosphates and organic phosphate, leaching concentration exceed the availability by regulatory (0.5 mg/L) in the whole L/S range, suggesting that the phosphate waste rocks stacked within the XXR watershed should be considered as Type II industry solid wastes. Therefore, the phosphate waste rocks deposited within the study area should be considered as phosphorus point pollution sources, which could threaten the adjacent surface-water environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Accelerated pavement testing of low-volume paved roads with geocell reinforcement : [technical summary].

    Science.gov (United States)

    2015-03-01

    The Midwest States Accelerated Pavement Testing Pooled-Fund Program, financed : by the highway departments of Kansas, Iowa, Missouri, and New York, has : supported an accelerated pavement testing (APT) project to study the rehabilitation : of low-vol...

  17. Accelerated corrosion test for metal drainage pipes : final report.

    Science.gov (United States)

    1987-06-01

    This study represents an attempt to develop an accelerated test which would assist the highway engineer in evaluating the usefulness of a new type of coated steel culvert. The test method was to be short in duration (in the order of days), and the re...

  18. Cross-current leaching of indium from end-of-life LCD panels.

    Science.gov (United States)

    Rocchetti, Laura; Amato, Alessia; Fonti, Viviana; Ubaldini, Stefano; De Michelis, Ida; Kopacek, Bernd; Vegliò, Francesco; Beolchini, Francesca

    2015-08-01

    Indium is a critical element mainly produced as a by-product of zinc mining, and it is largely used in the production process of liquid crystal display (LCD) panels. End-of-life LCDs represent a possible source of indium in the field of urban mining. In the present paper, we apply, for the first time, cross-current leaching to mobilize indium from end-of-life LCD panels. We carried out a series of treatments to leach indium. The best leaching conditions for indium were 2M sulfuric acid at 80°C for 10min, which allowed us to completely mobilize indium. Taking into account the low content of indium in end-of-life LCDs, of about 100ppm, a single step of leaching is not cost-effective. We tested 6 steps of cross-current leaching: in the first step indium leaching was complete, whereas in the second step it was in the range of 85-90%, and with 6 steps it was about 50-55%. Indium concentration in the leachate was about 35mg/L after the first step of leaching, almost 2-fold at the second step and about 3-fold at the fifth step. Then, we hypothesized to scale up the process of cross-current leaching up to 10 steps, followed by cementation with zinc to recover indium. In this simulation, the process of indium recovery was advantageous from an economic and environmental point of view. Indeed, cross-current leaching allowed to concentrate indium, save reagents, and reduce the emission of CO2 (with 10 steps we assessed that the emission of about 90kg CO2-Eq. could be avoided) thanks to the recovery of indium. This new strategy represents a useful approach for secondary production of indium from waste LCD panels. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. An acceleration test for stress corrosion cracking using humped specimen

    International Nuclear Information System (INIS)

    Kamaya, Masayuki; Fukumura, Takuya; Totsuka, Nobuo

    2003-01-01

    By using the humped specimen, which is processed by the humped die, in the slow strain rate technique (SSRT) test, fracture facet due to stress corrosion cracking (SCC) can be observed in relatively short duration. Although the cold work and concentrated stress and strain caused by the characteristic shape of the specimen accelerate the SCC, to date these acceleration effects have not been examined quantitatively. In the present study, the acceleration effects of the humped specimen were examined through experiments and finite element analyses (FEA). The experiments investigated the SCC of alloy 600 in the primary water environment of a pressurized water reactor. SSRT tests were conducted using two kinds of humped specimen: one was annealed after hump processing in order to eliminate the cold work, and the other was hump processed after the annealing treatment. The work ratio caused by the hump processing and stress/strain conditions during SSRT test were evaluated by FEA. It was found that maximum work ratio of 30% is introduced by the hump processing and that the distribution of the work ratio is not uniform. Furthermore, the work ratio is influenced by the friction between the specimen and dies as well as by the shape of dies. It was revealed that not only the cold work but also the concentrated stress and strain during SSRT test accelerate the crack initiation and growth of the SCC. (author)

  20. Directions of development of research methods in the assessment of leaching of heavy metals from mineral waste

    Directory of Open Access Journals (Sweden)

    Król Anna

    2016-01-01

    Full Text Available There are many test methods to assess the level of the release of heavy metals into the environment from mineral waste materials. Leaching methods can be different depending on the leaching time periods, leaching dynamics, sample preparation method or the pH of the elution medium. In Poland, little attention is paid to the research on the relationship between the leaching of particular heavy metals from mineral wastes and changes in environmental conditions, including the pH of the environment. Tests being carried out abroad have started to pay great attention to the pH-dependent impact of the environment and the liquid being in contact with the material on the degree of leaching contaminants from wastes. The solubility of all metals depends on the value of the pH. Authors of the paper will try to prove that Polish methods of waste characterization is incomplete and inconsistent with opinions prevailing in the global literature. The procedure described in the Polish standards are insufficient to determine the actual level of leaching of heavy metals having regard to the impact of multiple external conditions on the level of leaching of heavy metals. Paper will present a directions of development of research methods in the assessment of leaching of heavy metals from mineral waste.

  1. Toxicity assessment and geochemical model of chromium leaching from AOD slag.

    Science.gov (United States)

    Liu, Bao; Li, Junguo; Zeng, Yanan; Wang, Ziming

    2016-02-01

    AOD (Argon Oxygen Decarburization) slag is a by-product of the stainless steel refining process. The leaching toxicity of chromium from AOD slag cannot be ignored in the recycling process of the AOD slag. To assess the leaching toxicity of the AOD slag, batch leaching tests have been performed. PHREEQC simulations combined with FactSage were carried out based on the detailed mineralogical analysis and petrophysical data. Moreover, Pourbaix diagram of the Cr-H2O system was protracted by HSC 5.0 software to explore the chromium speciation in leachates. It was found that AOD slag leachate is an alkaline and reductive solution. The Pourbaix diagram of the Cr-H2O system indicated that trivalent chromium, such as Cr(OH)4(-), is the major chromium species in the experimental Eh-pH region considered. However, toxic hexavalent chromium was released with maximum concentrations of 30 µg L(-1) and 18 µg L(-1) at L/S 10 and 100, respectively, during the earlier leaching stage. It concluded that the AOD slag possessed a certain leaching toxicity. After 10 d of leaching, trivalent chromium was the dominant species in the leachates, which corresponded to the results of PHREEQC simulation. Leaching toxicity of AOD slag is based on the chromium speciation and its transformation. Great attention should be focused on such factors as aging, crystal form of chromium-enriched minerals, and electrochemical characteristics of the leachates. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Phosphate Leaching from Green Roof Substrates—Can Green Roofs Pollute Urban Water Bodies?

    Directory of Open Access Journals (Sweden)

    Agnieszka Karczmarczyk

    2018-02-01

    Full Text Available Green roofs are an effective stormwater measure due to high water retention capacity and the ability of delaying stormwater runoff. However, low importance is still given to the pollutant leaching potential of substrates used in green roof construction. The aim of the study is to estimate the concentrations and loads of P-PO43− in runoff from extensive and intensive substrates. To achieve this goal, several commonly-used fresh substrates were analyzed for P-PO43− leaching potential in different scale experiments, from laboratory batch tests, leaching column experiments, and long-term monitoring of open air green roof containers. The results of the study confirmed that fresh green roof substrates contain phosphorus in significant amounts of 17–145 mg∙P-PO43−/kg and, thus, can contribute to eutrophication of freshwater ecosystems. High correlation between phosphate content estimated by HCl extraction and cumulative load in leachate tests suggests that the batch HCl extraction test can be recommended for the comparison and selection of substrates with low potential P leaching. Volume-weighted mean concentrations and UALs of P-PO43− leaching from fresh substrates were higher in cases of intensive substrates, but there was no clear relationship between substrate type and the observed P-PO43− concentration range. To avoid increasing eutrophication of urban receivers the implementation of P reduction measures is strongly recommended.

  3. Time-dependent diffusive acceleration of test particles at shocks

    Energy Technology Data Exchange (ETDEWEB)

    Drury, L.O' C. (Dublin Inst. for Advanced Studies (Ireland))

    1991-07-15

    The acceleration of test particles at a steady plane non-relativistic shock is considered. Analytic expressions are found for the mean and the variance of the acceleration time distribution in the case where the diffusion coefficient has an arbitrary dependence on position and momentum. These expressions are used as the basis for an approximation scheme which is shown, by comparison with numerical solutions, to give an excellent representation of the time-dependent spectrum. (author).

  4. Time-dependent diffusive acceleration of test particles at shocks

    International Nuclear Information System (INIS)

    Drury, L.O'C.

    1991-01-01

    The acceleration of test particles at a steady plane non-relativistic shock is considered. Analytic expressions are found for the mean and the variance of the acceleration time distribution in the case where the diffusion coefficient has an arbitrary dependence on position and momentum. These expressions are used as the basis for an approximation scheme which is shown, by comparison with numerical solutions, to give an excellent representation of the time-dependent spectrum. (author)

  5. Sorption and leaching of benzalkonium chlorides in agricultural soils.

    Science.gov (United States)

    Khan, Adnan Hossain; Macfie, Sheila M; Ray, Madhumita B

    2017-07-01

    The adsorption and leaching characteristics of two commonly used benzalkonium chlorides (BACs), benzyl dimethyl dodecyl ammonium chloride (BDDA) and benzyl dimethyl tetradecyl ammonium chloride (BDTA) using three agricultural soils with varied proportions of silt, sand, clay, and organic matter were determined. BACs are cationic surfactants used in large quantities for sanitary and personal care products and are abundant in environmental samples. Adsorption isotherm data (aqueous concentration in the range of 25-150 mg L -1 ) fitted the Langmuir model better than the Freundlich model. BDTA with a longer alkyl chain adsorbed more to soil compared to BDDA, and the soil with the highest percentage of clay adsorbed the most. Column tests conducted using soils amended with lime stabilised biosolids and artificial rain water at a flow rate of 0.2 mL min -1 indicate very low leaching of BACs. Less than 1% of the available BDDA leached through sandy loam soil column with a depth of 9 cm. Therefore, the possibility of BACs to become bioavailable through leaching is very low at environmentally relevant concentrations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The structure of leached sodium borosilicate glass

    International Nuclear Information System (INIS)

    Bunker, B.C.; Tallant, D.R.; Headley, T.J.; Turner, G.L.; Kirkpatrick, R.J.

    1988-01-01

    Raman spectroscopy, solid state 29 Si, 11 B, 17 O, and 23 Na nuclear magnetic resonance spectroscopy, and transmission electron microscopy have been used to investigate how the structures of sodium borosilicate glasses change during leaching in water at pH 1, 9, and 12. Results show that the random network structure present prior to leaching is transformed into a network of small condensed ring structures and/or colloidal silica particles. The restructuring of leached glass can be rationalised on the basis of simple hydrolysis (depolymerisation) and condensation (repolymerisation) reactions involving Si-O-Si and Si-O-B bonds. The structural changes that occur during leaching influence the properties of the leached layer, including leaching kinetics, crazing and spalling, and slow crack growth. (author)

  7. Leaching and recovery of zinc and copper from brass slag by sulfuric acid

    Directory of Open Access Journals (Sweden)

    I.M. Ahmed

    2016-09-01

    Full Text Available Leaching and recovery processes for zinc and copper from brass slag by sulfuric acid were carried out and iron and aluminum were also precipitated as hydroxides in addition to silica gel. The factors affecting the performance and efficiency of the leaching processsuch as agitation rate, leaching time, acid concentration and temperature were separately investigated. The results obtained revealed that zinc and copper are successfully recovered from these secondary resources, where the percent recovery amounts to 95% and 99% for zinc and copper, respectively. The experimental data of this leaching process were well interpreted with the shrinking core model under chemically controlled processes. The apparent activation energy for the leaching of zinc has been evaluated using the Arrhenius expression. Based on the experimental results, a separation method and a flow sheet were developed and tested to separate zinc, copper, iron, aluminum and silica gel from the brass slag.

  8. High gradient test of the C-band choke-mode type accelerating structure

    International Nuclear Information System (INIS)

    Inagaki, T.; Shintake, T.; Baba, H.; Togawa, K.; Onoe, K.; Marechal, X.; Takashima, T.; Takahashi, S.; Matsumoto, H.

    2004-01-01

    The C-band (5712 MHz) choke-mode type accelerating structure will be used for SPring-8 Compact SASE-FEL Source (SCSS). To make the accelerator length short, we designed the field gradient as high as 40 MV/m. Since it is higher gradient than other traditional electron accelerators, we have to carefully check its performance (RF breakdown, dark current emission, etc.) in the high gradient test stand. The first experiment will be scheduled in this summer. In this paper, we will describe the preparation progress for the test. (author)

  9. Determining leach rates of monolithic waste forms

    International Nuclear Information System (INIS)

    Gilliam, T.M.; Dole, L.R.

    1986-01-01

    The ANS 16.1 Leach Procedure provides a conservative means of predicting long-term release from monolithic waste forms, offering a simple and relatively quick means of determining effective solid diffusion coefficients. As presented here, these coefficients can be used in a simple model to predict maximum release rates or be used in more complex site-specific models to predict actual site performance. For waste forms that pass the structural integrity test, this model also allows the prediction of EP-Tox leachate concentrations from these coefficients. Thus, the results of the ANS 16.1 Leach Procedure provide a powerful tool that can be used to predict the waste concentration limits in order to comply with the EP-Toxicity criteria for characteristically nonhazardous waste. 12 refs., 3 figs

  10. Leaching of saltstones containing fly ash

    International Nuclear Information System (INIS)

    Barnes, M.W.; Roy, D.M.; Langton, C.A.

    1985-01-01

    Two types of fly ash were incorporated in saltstones designed for potential encapsulation of Savannah River Plant low level defense waste. These fly ashes have some cementitious properties while at the same time their presence in substitution for cement slows early hydration. Class C fly ash has a high calcium content and is considered cementitious; Class F fly ash has a low calcium content and is not classified as cementitious. Leach tests were performed and physical properties were measured for saltstones containing each class, to see the differences in the effect of the fly ashes. The four waste ions nitrate, nitrite, sodium and sulfate were shown to leach by diffusion. Effective diffusivities were determined for these ions. Data for nitrate, the most important species from the environmental point of view, are shown in Table A. Saltstones made with Class C fly ash have substantially lower leach rates than those made with Class F fly ash. The leach rates, and therefore the square roots of the effective diffusivities, have been found to be proportional to the pore surface area per unit volume (or the ratio of pore volume to pore radius), to the fraction of waste containing solution, and to the inverse of the fraction of calcium in the saltstone. Rates and diffusivities are not proportional to the water to cement ratio, because this number depends on whether the fly ash is counted as cementitious, as in Class C cement, or not cementitious, as in Class F cement. In fact the relatively small amount of calcium in Class F cement contributes to the cementitious properties overall, though not so much as Class C cement. 4 refs., 2 figs., 6 tabs

  11. Ultra-Accelerated Natural Sunlight Exposure Testing Facilities

    Science.gov (United States)

    Lewandowski, Allan A.; Jorgensen, Gary J.

    2004-11-23

    A multi-faceted concentrator apparatus for providing ultra-accelerated natural sunlight exposure testing for sample materials under controlled weathering conditions comprising: facets that receive incident natural sunlight, transmits VIS/NIR and reflects UV/VIS onto a secondary reflector that delivers a uniform flux of UV/VIS onto a sample exposure plane located near a center of a facet array in a chamber that provide concurrent levels of temperature and/or relative humidity at high levels of up to 100.times. of natural sunlight that allow sample materials to be subjected to accelerated irradiance exposure factors for a significant period of time of about 3 to 10 days to provide a corresponding time of about at least a years worth representative weathering of sample materials.

  12. Commissioning of the Ground Test Accelerator RFQ

    International Nuclear Information System (INIS)

    Johnson, K.F.; Sander, O.R.; Atkins, W.H.; Bolme, G.O.; Brown, S.; Connolly, R.; Garnett, R.; Gilpatrick, J.D.; Guy, F.W.; Ingalls, W.B.; Little, C.; Lohson, R.A.; Lloyd, S.; Neuschaefer, G.; Power, J.; Saadatmand, K.; Sandoval, D.P.; Stevens, R.R.; Vaughn, G.; Wadlinger, E.A.; Weiss, R.; Yuan, V.

    1992-01-01

    The Ground Test Accelerator (GTA) has the objective of verifying much of the technology (physics and engineering) required for producing high-brightness, high-current H - beams. GTA commissioning is staged to verify the beam dynamics design of each major accelerator component as it is brought on-line. The commissioning stages are the 35 key H - injector, the 2.5 MeV Radio Frequency Quadrupole (RFQ), the Intertank Matching Section (IMS), the 3.2 MeV first 2βγ Drift Tube Linac (DTL-1) module, the 8.7 MeV 2βγ DTL (modules 1--5), and the 24 MeV GTA; all 10 DTL modules. Commissioning results from the RFQ beam experiments will be presented along with comparisons to simulations

  13. Commissioning of the ground test accelerator RFQ

    International Nuclear Information System (INIS)

    Johnson, K.F.; Sander, O.R.; Atkins, W.H.; Bolme, G.O.; Brown, S.; Garnott, R.; Gilpatrick, J.D.; Guy, F.W.; Ingalls, W.B.; Little, C.; Lohsen, R.A.; Lloyd, S.; Neuschaefer, G.; Power, J.; Sandoval, D.P.; Saadatmand, K.; Stevens, R.R.Jr.; Vaughn, G.; Wadlinger, E.A.; Yuan, V.; Connolly, R.; Weiss, R.

    1992-01-01

    The Ground Test Accelerator (GTA) has the objective of verifying much of the technology (physics and engineering) required for producing high-brightness, high-current H - beams. GTA commissioning is staged to verify the beam dynamics design of each major accelerator component as it is brought on line. The commissioning stages are the 35-keV H - injector, the 2.5-MeV radio-frequency quadrupole (RFQ), the intertank matching section (IMS), the 3.2-MeV first 2-βλ drift tube linac (DTL-1) module, the 8.7-MeV 2-βλDTL (modules 1-5), and the 24-MeV GTA (all 10 DTL modules). Commissioning results from the RFQ beam experiments are presented along with comparisons with simulations. (Author) 8 refs., 9 figs

  14. Long-term leaching from MSWI air-pollution-control residues: Leaching characterization and modeling

    DEFF Research Database (Denmark)

    Hyks, Jiri; Astrup, Thomas; Christensen, Thomas Højlund

    2009-01-01

    Long-term leaching of Ca, Fe, Mg, K, Na, S, Al, As, Ba, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Zn, Mo, Sb, Si, Sri, Sr, Ti, V, P, Cl, and dissolved organic carbon from two different municipal solid waste incineration (MSWI) air-pollution-control residues was monitored during 24 months of column percolat......Long-term leaching of Ca, Fe, Mg, K, Na, S, Al, As, Ba, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Zn, Mo, Sb, Si, Sri, Sr, Ti, V, P, Cl, and dissolved organic carbon from two different municipal solid waste incineration (MSWI) air-pollution-control residues was monitored during 24 months of column...... percolation experiments; liquid-to-solid (L/S) ratios of 200-250 L/kg corresponding to more than 10,000 years in a conventional landfill were reached. Less than 2% of the initially present As, Cu, Pb, Zn, Cr, and Sb had leached during the Course of the experiments. Concentrations of Cd, Fe, Mg, Hg, Mn, Ni, Co......, Sn, Ti, and P were generally bellow 1 mu g/L; overall less than 1% of their mass leached. Column leaching data were further used in a two-step geochemical modeling in PHREEQC in order to (i) identify solubility controlling minerals and (ii) evaluate their interactions in a water-percolated column...

  15. RF pulse compression in the NLC test accelerator at SLAC

    International Nuclear Information System (INIS)

    Lavine, T.L.

    1995-01-01

    At the Stanford Linear Accelerator Center (SLAC), we are designing a Next Linear Collider (NLC) with linacs powered by X-band klystrons with rf pulse compression. The design of the linac rf system is based on X-band prototypes which have been tested at high power, and on a systems-integration test---the Next Linear Collider Test Accelerator (NLCTA)---which is currently under construction at SLAC. This paper discusses some of the systems implications of rf pulse compression, and the use of pulse compression in the NLCTA, both for peak power multiplication and for controlling, by rf phase modulation, intra-pulse variations in the linac beam energy. copyright 1995 American Institute of Physics

  16. High power testing oa ANL X-band dielectric-loaded accelerating structures

    International Nuclear Information System (INIS)

    Power, J. G.; Gai, W.; Jing, C.; Konecny, R.; Gold, S. H.; Kinkead, A. K.

    2002-01-01

    In the second phase of a program to develop a compact accelerator based on a dielectric-loaded accelerating structure, we have conducted high power tests on a traveling-wave and a standing-wave prototype. Indications are that the traveling-wave structure achieved an accelerating gradient of 3-5 MV/m before the input coupling window failed, while the standing wave structure was poorly matched at high power due to contamination of copper residue on its coupling window. To solve both of these problems, a new method for coupling RF into the structures has been developed. The new couplers and the rest of the modular structure are currently under construction and will be tested at the Naval Research Laboratory shortly

  17. Leaching studies on ion exchange resins immobilized in bitumen matrix

    International Nuclear Information System (INIS)

    Grosche Filho, C.E.; Chandra, U.; Villalobos, J.P.

    1986-01-01

    Many samples of bitumen mixed with ion exchange resin labelled with 134 Cs were prepared to study radionuclide leaching from bitumen waste forms. The resins used in tests were nuclear grade mixed cationic/aniocic bead resins. Different bitumen types were assayed: two distilled and two oxidized bitumens. Leached fractions were collected accordingly to the recommendation of ISO method, with complete exchange of leachant after each sampling. The volume collected for analysis was one liter. Marinelli beckers were used to improve counting efficiency in a Ge(Li) detector. The diffusion coefficients for samples prepared with distilled and oxidized bitumens were obtained. Mathematical models of transport phenomena applied to cylindrical geometry was employed to fit experimental data aiming to explain leaching mechanism and predict the long time behavior of immobilized radionuclides. (M.C.K.) [pt

  18. Poisson simulation for high voltage terminal of test stand for 1MV electrostatic accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae-Hoon; Kim, Jeong-Tae; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Yu-Seok [Dongguk Univ.., Gyeongju (Korea, Republic of)

    2014-10-15

    KOMAC provide ion beam to user which energy range need to expand to MeV range and develop 1 MV electrostatic accelerator. The specifications of the electrostatic accelerator are 1MV acceleration voltage, 10 mA peak current and variable gas ion. We are developing test stand before set up 1 MV electrostatic accelerator. The test stand voltage is 300 kV and operating time is 8 hours. The test stand is consist of 300 kV high voltage terminal, DC-AC-DC inverter, power supply device inside terminal, 200MHz RF power, 5 kV extraction power supply, 300 kV accelerating tube and vacuum system.. The beam measurement system and beam dump will be installed next to accelerating tube. Poisson code simulation results of the high voltage terminal are presented in this paper. Poisson code has been used to calculate the electric field for high voltage terminal. The results of simulation were verified with reasonable results. The poisson code structure could be apply to the high voltage terminal of the test stand.

  19. Poisson simulation for high voltage terminal of test stand for 1MV electrostatic accelerator

    International Nuclear Information System (INIS)

    Park, Sae-Hoon; Kim, Jeong-Tae; Kwon, Hyeok-Jung; Cho, Yong-Sub; Kim, Yu-Seok

    2014-01-01

    KOMAC provide ion beam to user which energy range need to expand to MeV range and develop 1 MV electrostatic accelerator. The specifications of the electrostatic accelerator are 1MV acceleration voltage, 10 mA peak current and variable gas ion. We are developing test stand before set up 1 MV electrostatic accelerator. The test stand voltage is 300 kV and operating time is 8 hours. The test stand is consist of 300 kV high voltage terminal, DC-AC-DC inverter, power supply device inside terminal, 200MHz RF power, 5 kV extraction power supply, 300 kV accelerating tube and vacuum system.. The beam measurement system and beam dump will be installed next to accelerating tube. Poisson code simulation results of the high voltage terminal are presented in this paper. Poisson code has been used to calculate the electric field for high voltage terminal. The results of simulation were verified with reasonable results. The poisson code structure could be apply to the high voltage terminal of the test stand

  20. Cross-current leaching of indium from end-of-life LCD panels

    Energy Technology Data Exchange (ETDEWEB)

    Rocchetti, Laura; Amato, Alessia; Fonti, Viviana [Department of Life and Environmental Sciences, Università Politecnica delle Marche, Via Brecce Bianche, 60131 Ancona (Italy); Ubaldini, Stefano [Institute of Environmental Geology and Geoengineering IGAG, National Research Council, Via Salaria km 29300, 00015 Montelibretti, Rome (Italy); De Michelis, Ida [Department of Industrial Engineering, Information and Economy, University of L’Aquila, Via Giovanni Gronchi 18, 67100, Zona industriale di Pile, L’Aquila (Italy); Kopacek, Bernd [ISL Kopacek KG, Beckmanngasse 51, 1140 Wien (Austria); Vegliò, Francesco [Department of Industrial Engineering, Information and Economy, University of L’Aquila, Via Giovanni Gronchi 18, 67100, Zona industriale di Pile, L’Aquila (Italy); Beolchini, Francesca, E-mail: f.beolchini@univpm.it [Department of Life and Environmental Sciences, Università Politecnica delle Marche, Via Brecce Bianche, 60131 Ancona (Italy)

    2015-08-15

    Graphical abstract: Display Omitted - Highlights: • End-of-life LCD panels represent a source of indium. • Several experimental conditions for indium leaching have been assessed. • Indium is completely extracted with 2 M sulfuric acid at 80 °C for 10 min. • Cross-current leaching improves indium extraction and operating costs are lowered. • Benefits to the environment come from reduction of CO{sub 2} emissions and reagents use. - Abstract: Indium is a critical element mainly produced as a by-product of zinc mining, and it is largely used in the production process of liquid crystal display (LCD) panels. End-of-life LCDs represent a possible source of indium in the field of urban mining. In the present paper, we apply, for the first time, cross-current leaching to mobilize indium from end-of-life LCD panels. We carried out a series of treatments to leach indium. The best leaching conditions for indium were 2 M sulfuric acid at 80 °C for 10 min, which allowed us to completely mobilize indium. Taking into account the low content of indium in end-of-life LCDs, of about 100 ppm, a single step of leaching is not cost-effective. We tested 6 steps of cross-current leaching: in the first step indium leaching was complete, whereas in the second step it was in the range of 85–90%, and with 6 steps it was about 50–55%. Indium concentration in the leachate was about 35 mg/L after the first step of leaching, almost 2-fold at the second step and about 3-fold at the fifth step. Then, we hypothesized to scale up the process of cross-current leaching up to 10 steps, followed by cementation with zinc to recover indium. In this simulation, the process of indium recovery was advantageous from an economic and environmental point of view. Indeed, cross-current leaching allowed to concentrate indium, save reagents, and reduce the emission of CO{sub 2} (with 10 steps we assessed that the emission of about 90 kg CO{sub 2}-Eq. could be avoided) thanks to the recovery of indium

  1. Copper Leaching from Copper-ethanolamine Treated Wood: Comparison of Field Test Studies and Laboratory Standard Procedures

    OpenAIRE

    Nejc Thaler; Miha Humar

    2014-01-01

    Copper-based compounds are some of the most important biocides for the protection of wood in heavy duty applications. In the past, copper was combined with chromium compounds to reduce copper leaching, but a recent generation of copper-based preservatives uses ethanolamine as a fixative. To elucidate the leaching of copper biocides from wood, Norway spruce (Picea abies) wood was treated with a commercial copper-ethanolamine solution with two different copper concentrations (cCu = 0.125% and 0...

  2. Life cycle assessment and residue leaching: the importance of parameter, scenario and leaching data selection.

    Science.gov (United States)

    Allegrini, E; Butera, S; Kosson, D S; Van Zomeren, A; Van der Sloot, H A; Astrup, T F

    2015-04-01

    Residues from industrial processes and waste management systems (WMSs) have been increasingly reutilised, leading to landfilling rate reductions and the optimisation of mineral resource utilisation in society. Life cycle assessment (LCA) is a holistic methodology allowing for the analysis of systems and products and can be applied to waste management systems to identify environmental benefits and critical aspects thereof. From an LCA perspective, residue utilisation provides benefits such as avoiding the production and depletion of primary materials, but it can lead to environmental burdens, due to the potential leaching of toxic substances. In waste LCA studies where residue utilisation is included, leaching has generally been neglected. In this study, municipal solid waste incineration bottom ash (MSWI BA) was used as a case study into three LCA scenarios having different system boundaries. The importance of data quality and parameter selection in the overall LCA results was evaluated, and an innovative method to assess metal transport into the environment was applied, in order to determine emissions to the soil and water compartments for use in an LCA. It was found that toxic impacts as a result of leaching were dominant in systems including only MSWI BA utilisation, while leaching appeared negligible in larger scenarios including the entire waste system. However, leaching could not be disregarded a priori, due to large uncertainties characterising other activities in the scenario (e.g. electricity production). Based on the analysis of relevant parameters relative to leaching, and on general results of the study, recommendations are provided regarding the use of leaching data in LCA studies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Effects of Pregnant Leach Solution Temperature on the Permeability of Gravelly Drainage Layer of Heap Leaching Structures

    Directory of Open Access Journals (Sweden)

    mehdi amini

    2013-12-01

    Full Text Available In copper heap leaching structures, the ore is leached by an acidic solution. After dissolving the ore mineral, the heap is drained off in the acidic solution using a drainage system (consisting of a network of perforated polyethylene pipes and gravelly drainage layers and is, then, transferred to the leaching plant for copper extraction where the copper is extracted and the remaining solution is dripped over the ore heap for re-leaching. In this process, the reaction between the acidic solution and copper oxide ore is exothermal and the pregnant leach solution (PLS, which is drained off the leaching heap, has a higher temperature than the dripped acidic solution. The PLS temperature variations cause some changes in the viscosity and density which affect the gravelly drainage layer's permeability. In this research, a special permeability measuring system was devised for determining the effects of the PLS temperature variations on the permeability coefficient of the gravelly drainage layer of heap leaching structures. The system, consisting of a thermal acid resistant element and a thermocouple, controls the PLS temperature, which helps measure the permeability coefficient of the gravelly drainage layer. The PLS and gravelly drainage layer of Sarcheshmeh copper mine heap leaching structure No. 1 were used in this study. The permeability coefficient of the gravelly soil was measured against the PLS and pure water at temperatures varying between 3°C to 60°C. Also, the viscosity and density of the PLS and pure water were measured at these temperatures and, using existing theoretical relations, the permeability coefficient of the gravel was computed. A comparison between the experimental and theoretical results revealed a good conformity between the two sets of results. Finally, a case (Taft heap leaching structure, Yazd, Iran was studied and its gravelly drainage layer was designed based on the results of the present research.

  4. Uranium extraction history using pressure leaching

    International Nuclear Information System (INIS)

    Fraser, K.S.; Thomas, K.G.

    2010-01-01

    Over the past 60 years of uranium process development only a few commercial uranium plants have adopted a pressure leaching process in their flowsheet. The selection of acid versus alkaline pressure leaching is related to the uranium and gangue mineralogy. Tetravalent (U"+"4) uranium has to be oxidized to hexavalent (U"+"6) uranium to be soluble. Refractory tetravalent uranium requires higher temperature and pressure, as practised in pressure leaching, for conversation to soluble hexavalent uranium. This paper chronicles the history of these uranium pressure leaching facilities over the past 60 years, with specific details of each design and operation. (author)

  5. A new Leaching System, Sheta Extractor

    International Nuclear Information System (INIS)

    Sheta, M.E.

    2008-01-01

    Moving of crushed solid ores against leaching solution in a continuous countercurrent arises a true technical problem. This invented system introduces a practical solution for such problem. Inside the system, the crushed ore is driving against gravity, whereas the leaching solution moves in the opposite direction. Contact between the two phases occurs with gentle stirring. After contact, discharging of the processed phases takes place automatically out the system. The system was investigated for uranium leaching from a coarse grained fraction (+2 --- -- -30 mm) of uranium mineralized granite sample. Uranium leaching percent reached to nearly 50% using sulfuric acid

  6. Practice of the counter-current trickle leaching of uranium ore by refreshed liquor of bacterial oxidation

    International Nuclear Information System (INIS)

    Chen Shian; Huang Xiangfu; Fan Baotuan

    1995-01-01

    The uranium ore of the Mine No. 753 is a high-silicate type primary one, in which the tetravalent uranium accounts for 85%, and the uranium grade is in the range of 0.36% to 0.442%. To reduce the engineering investment and the operating cost a four-stage counter-current trickle leaching pilot-plant test was carried out with the leaching time 50 days and acid consumption 38 kg per ton of ore, and the recovery of more than 95% was obtained. Using the counter-current trickle leaching mode and controlling the limit concentration of the harmful matters in the bacterial leaching liquor, the latter can be effectively oxidized by the synchronical regeneration. A trickle leaching comparative test of 25 ton ore single heap also gave a good result of more than 95% in extraction rate, and 30% acid consumption was saved and the 2.0% pyrolusite (containing MnO 2 40%) was eliminated. This process is feasible in technology and worth-while in economy for treating the uranium ore of Mine No. 753, and provides a new method of uranium ore trickle leaching

  7. Chemo-mechanical coupling behaviour of leached concrete

    International Nuclear Information System (INIS)

    Nguyen, V.H.; Nedjar, B.; Torrenti, J.M.

    2007-01-01

    The paper is concerned with a coupled chemo-mechanical model describing the interaction between the calcium leaching and the mechanical damage in concrete materials. On the one hand, the phenomenological chemistry is described by the nowadays well-known simplified calcium leaching approach. It is based on the dissolution-diffusion process together with the chemical equilibrium relating the calcium concentration of the solid's skeleton and the calcium in the pore solution. For concrete, a homogenization approach using asymptotic expansions is used to take into account the influence of the presence of the aggregates leading to an equivalent homogeneous medium. On the other hand, the continuum damage mechanics is used to describe the mechanical degradation of concrete. The modelling accounts for the fact that concrete becomes more and more ductile as the leaching process grows. The model also predicts the inelastic irreversible deformation as damage evolves. The growth of inelastic strains observed during the mechanical tests is described by means of an elastoplastic-like model. The coupled nonlinear problem at hand is addressed within the context of the finite element method. And finally, numerical simulations are compared with the experimental results of first part of this work

  8. Leaching of 14C and 36Cl from irradiated French graphite

    International Nuclear Information System (INIS)

    Gray, W.J.; Morgan, W.C.

    1989-08-01

    The leach rates of 14 C and 36 Cl were measured on solid cylindrical samples prepared from irradiated graphite blocks supplied by the French Commissariat a l'Energie Atomique (CEA). Static leach tests were conducted in deionized water at 20 degree C for 13 weeks. The graphite samples were completely submerged in the water, and the entire volume of water was changed and analyzed at weekly intervals for the first three weeks and biweekly thereafter. Large differences in the leach rates of both 14 C and 36 Cl were observed between samples machined from the different blocks. In general, the leach rates were much higher than those measured in an earlier study with graphite obtained from a block removed from one of the Hanford reactors. The data from this study are compared with those from the previous study using the Hanford-reactor graphite. Implications of the data from both studies regarding possible rate-limiting mechanisms are discussed. 4 refs., 8 figs., 3 tabs

  9. Weatherability and Leach Resistance of Wood Impregnated with Nano-Zinc Oxide

    Directory of Open Access Journals (Sweden)

    Nami Kartal S

    2010-01-01

    Full Text Available Abstract Southern pine specimens vacuum-treated with nano-zinc oxide (nano-ZnO dispersions were evaluated for leach resistance and UV protection. Virtually, no leaching occurred in any of the nano-ZnO–treated specimens in a laboratory leach test, even at the highest retention of 13 kg/m3. However, specimens treated with high concentrations of nano-ZnO showed 58–65% chemical depletion after 12 months of outdoor exposure. Protection from UV damage after 12 months exposure is visibly obvious on both exposed and unexposed surfaces compared to untreated controls. Graying was markedly diminished, although checking occurred in all specimens. Nano-zinc oxide treatment at a concentration of 2.5% or greater provided substantial resistance to water absorption following 12 months of outdoor exposure compared to untreated and unweathered southern pine. We conclude that nano-zinc oxide can be utilized in new wood preservative formulations to impart resistance to leaching, water absorption and UV damage of wood.

  10. Test Particles with Acceleration-Dependent Lagrangian

    OpenAIRE

    Toller, M.

    2005-01-01

    We consider a classical test particle subject to electromagnetic and gravitational fields, described by a Lagrangian depending on the acceleration and on a fundamental length. We associate to the particle a moving local reference frame and we study its trajectory in the principal fibre bundle of all the Lorentz frames. We discuss in this framework the general form of the Lagrange equations and the connection between symmetries and conservation laws (Noether theorem). We apply these results to...

  11. Some practical observations on the accelerated testing of Nickel-Cadmium Cells

    Science.gov (United States)

    Mcdermott, P. P.

    1979-01-01

    A large scale test of 6.0 Ah Nickel-Cadmium Cells conducted at the Naval Weapons Support Center, Crane, Indiana has demonstrated a methodology for predicting battery life based on failure data from cells cycled in an accelerated mode. After examining eight variables used to accelerate failure, it was determined that temperature and depth of discharge were the most reliable and efficient parameters for use in accelerating failure and for predicting life.

  12. Microbial leaching of low grade sandstone uranium ores: column leaching studies

    International Nuclear Information System (INIS)

    Bhatti, T.M.; Malik, K.A.; Khalid, A.M.

    1991-01-01

    Microbial leaching studies on a low-grade sandstone uranium ore from Baghalchur Ore Deposits, D. G. Khan, Pakistan, containing 0.027 % U/sub 3/O/sub 8/ for extraction of uranium, were conducted in columns. Baghalchur sandstone uranium ore which is alkaline in nature, contained 5.0% calcite [CaCo/sub 3/], 2-3 % Fe/sub 2/O/sub 3/ and pyrite [FeS/sub 2/] less than 0.1 %. The ore amended with sulfur and/or sulfur slag as external energy source was found to leach with indigenous microflora mostly belonging to the genus Thiobacillus which are present in the uranium mine water. Column leaching studies revealed that when the ore was amended with elemental sulfur and irrigated with mine water (pH 3.5) 53 % U/sub 3/O/sub 8/ could be solubilized from it. However, when the natural mine water was used as such (pH 7.4) the solubilization of uranium was decreased to 41 % U/sub 3/O/sub 8/ in 90 days under similar conditions of percolation rate and temperature. The addition of (NH/sub 4/)/sub 2/SO/sub 4/ (3.0 g/L) in mine water was found to enhance the uranium leaching to 70 % U/sub 3/O/sub 8/ from the columns containing ore amended with sulfur slag. (author)

  13. PRESERVATIVE LEACHING FROM WEATHERED CCA-TREATED WOOD

    Science.gov (United States)

    Disposal of discarded CCA-treated wood in landfills raises concerns with respect to leaching of preservative compounds. When unweathered CCA-treated wood is leached using the toxicity characteristic leaching procedure (TCLP), arsenic concentrations exceed the toxicity characteris...

  14. Arsenic-containing soil from geogenic source in Hong Kong: Leaching characteristics and stabilization/solidification.

    Science.gov (United States)

    Li, Jiang-Shan; Beiyuan, Jingzi; Tsang, Daniel C W; Wang, Lei; Poon, Chi Sun; Li, Xiang-Dong; Fendorf, Scott

    2017-09-01

    Geogenic sources of arsenic (As) have aroused extensive environmental concerns in many countries. This study evaluated the vertical profiles, leaching characteristics, and surface characteristics of As-containing soils in Hong Kong. The results indicated that elevated levels of As (486-1985 mg kg -1 ) were mostly encountered in deeper layer (15-20 m below ground). Despite high concentrations, geogenic As displayed a high degree of chemical stability in the natural geochemical conditions, and there was minimal leaching of As in various leaching tests representing leachability, mobility, phytoavailability, and bioaccessibility. Microscopic/spectroscopic investigations suggested that As in the soils was predominantly present as As(V) in a coordination environment with Fe oxides. Sequential extraction indicated that the majority of As were strongly bound with crystalline Fe/Al oxides and residual phase. Yet, uncertainties may remain with potential As exposure through accidental ingestion and abiotic/biotic transformation due to changes in geochemical conditions. Hence, the effectiveness of stabilization/solidification (S/S) treatment was evaluated. Although the leached concentrations of As from the S/S treated soils increased to varying extent in different batch leaching tests due to the increase in alkalinity, the mobility of As was considered very low based on semi-dynamic leaching test. This suggested that As immobilization in the S/S treated soils was predominantly dependent on physical encapsulation by interlocking framework of hydration products, which could also prevent potential exposure and allow controlled utilization of S/S treated soils as monolithic materials. These results illustrate the importance of holistic assessment and treatment/management of As-containing soils for enabling flexible future land use. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Accelerated testing statistical models, test plans, and data analysis

    CERN Document Server

    Nelson, Wayne B

    2009-01-01

    The Wiley-Interscience Paperback Series consists of selected books that have been made more accessible to consumers in an effort to increase global appeal and general circulation. With these new unabridged softcover volumes, Wiley hopes to extend the lives of these works by making them available to future generations of statisticians, mathematicians, and scientists. "". . . a goldmine of knowledge on accelerated life testing principles and practices . . . one of the very few capable of advancing the science of reliability. It definitely belongs in every bookshelf on engineering.""-Dev G.

  16. Comparative Study on the Leaching Characteristics of Industrial Sludge and Fly Ash using KSLP and TCLP Techniques

    International Nuclear Information System (INIS)

    Lee, B.K.; Hwang, H.W.

    2010-01-01

    Leaching characteristics of industrial sludge and fly ash using Korean Standard Leaching Procedure (KSLP) and Toxicity Characteristics Leaching Procedure (TCLP) were studied. Possibilities of re-adsorption of heavy metal ions on the surface of sludge and ash during the course of leaching were also investigated. KSLP looked relatively more aggressive than the TCLP in leaching heavy metal ions. Concentrations of metal ions leached in both the methods, however, were found very low in comparison to the concentration of ions present in the original samples. In case of sludge, heavy metal ions showed relatively high rate of leaching at fourth and fifth stages of sequential extraction while ash showed high rate of leaching at the first three stages of extraction. Some of the concentrations of heavy metal ions leached out in the tests also found to be adsorbed on the surface of sludge and ash. Heavy metal ions present in high concentrations in the sample showed lower rate of adsorption than their leaching rate. No distinct difference in the results of KSLP and TCLP was observed. However, variations in the leaching results could be due to the different nature of hazardous waste and leaching conditions. More information like kinetics of leaching, mineralogical characteristics of waste and site characteristics of landfill were required to predict more accurate leaching behavior of ions in natural conditions. (author)

  17. Basic leaching tests for pure beta long-lived emitters in radioactive wastes; Ensayos de lixiviacion de emisores beta puros de larga vida

    Energy Technology Data Exchange (ETDEWEB)

    Murillo, R; Almodovar, A; Gonzalez de la Huebra, A.

    1995-09-01

    Specimens for the two first leaching stages were manufactured using samples of virgin resins saturated in simulated conditions. EPIFLOC 21H resin was 50% saturated with NaCl and DUOLITE ARM-9381 resin was 100% saturated with NaCl+H{sub 3}BO{sub 3}. Previously both resins were doped with Ni-63 and Sr-90. As far as the third leaching stage is concerning, samples of real resins from two Spanish nuclear power plants were used for manufacturing of leaching specimens. Because Sr-90 and Ni-63 radioactivity in these samples was not high enough to be detectable in leachate, samples were additionally loaded with Sr-90 and Ni-63 before mixing with cement. Leaching procedure was adapted to the French one (the same duration of leaching renewal steps and cumulative leaching time and also the same analytical preparation for chemical and radiochemical analysis). Specimens were hanged into leachant with nylon yarn and were surrounded by a leachant layer of 3 cm thickness. Additionally to Sr-90 and Ni-63, the main chemical elements present in cements used for manufacturing of specimens were analyzed in leachates from the two first leaching stages and the main gamma emitters present in the samples of real resins were analyzed in leachates from the third leaching stages. (Author)

  18. Mechanism for elevated temperature leaching

    International Nuclear Information System (INIS)

    Kenna, B.T.; Murphy, K.D.

    1979-01-01

    Long-term, elevated temperature leaching and subsequent electron microprobe analysis of simulated waste glass and ceramic materials have been completed. A cyclic leaching pattern was found in all systems over a 20-month period. It appears that the leaching of mobile ions by simple diffusional processes is modified by more complex chemical interactions. The release of immobile ions is primarily a function of their chemical interactions in the matrix which suggests that these ions may be complex species when released into solution. A mechanism is proposed which incorporates these ideas and the cyclic phenomenon observed

  19. Bicarbonate leaching of uranium

    International Nuclear Information System (INIS)

    Mason, C.

    1998-01-01

    The alkaline leach process for extracting uranium from uranium ores is reviewed. This process is dependent on the chemistry of uranium and so is independent on the type of mining system (conventional, heap or in-situ) used. Particular reference is made to the geochemical conditions at Crownpoint. Some supporting data from studies using alkaline leach for remediation of uranium-contaminated sites is presented

  20. Bicarbonate leaching of uranium

    Energy Technology Data Exchange (ETDEWEB)

    Mason, C.

    1998-12-31

    The alkaline leach process for extracting uranium from uranium ores is reviewed. This process is dependent on the chemistry of uranium and so is independent on the type of mining system (conventional, heap or in-situ) used. Particular reference is made to the geochemical conditions at Crownpoint. Some supporting data from studies using alkaline leach for remediation of uranium-contaminated sites is presented.