Sample records for accelerated hyperfractionated imrt

  1. Accelerated hyperfractionated radiotherapy for malignant gliomas

    International Nuclear Information System (INIS)

    Buatti, John M.; Marcus, Robert B.; Mendenhall, William M.; Friedman, William A.; Bova, Francis J.

    1996-01-01

    Purpose: To evaluate accelerated hyperfractionated radiotherapy for the treatment of malignant gliomas. Methods and Materials: Between April 1985 and June 1994, 70 adult patients with pathologically confirmed malignant glioma (75% glioblastoma multiforme, 25% anaplastic astrocytoma) suitable for high-dose therapy were selected for treatment with accelerated hyperfractionated radiotherapy, 1.5 Gy twice daily to a total target dose of 60 Gy. Two patients were excluded from analysis (one patient had a fatal pulmonary embolism after 18 Gy; one patient discontinued therapy after 28.5 Gy against medical advice and without sequelae or progression). The 68 patients in the study group had a median age of 52 years and a median Karnofsky performance status of 90. Stereotactic implant ( 125 I) or stereotactic radiosurgery boosts were delivered to 16 patients (24%) in the study group. Minimum follow-up was 6 months. Results: Median survival was 13.8 months and median progression-free survival was 7.4 months. The absolute Kaplan-Meier survival rate was 16% at 2 years and 4% at 5 years. Multivariate analysis for the prognostic impact of age, gender, histology, Karnofsky performance status, symptomatology, surgical resection vs. biopsy, and boost vs nonboost therapy revealed that Karnofsky performance status ≥ 90, boost therapy, and surgical excision predicted significantly improved outcome. No severe toxicity occurred in patients treated with accelerated hyperfractionated radiotherapy alone, although 5% required steroids temporarily for edema. Progression occurred during treatment in one patient (1.5%). Conclusion: This regimen of accelerated hyperfractionated radiotherapy is well tolerated and leads to results comparable with those of standard therapy. The rate of disease progression during treatment is significantly better (p = 0.001) than is reported for patients treated with standard fractionation, with or without chemotherapy. This regimen is a reasonable starting point

  2. Assessment of long-term quality of life of esophageal carcinoma patients treated with continuous accelerated hyperfractionated and late-course accelerated hyperfractionated radiotherapy

    International Nuclear Information System (INIS)

    Wang Yang; He Shaoqin; Shi Xuehui; Jiang Kaida; Yao Weiqiang; Wang Ying

    2002-01-01

    Objective: To compare the long-term quality of life in esophageal carcinoma patients treated with continuous accelerated hyperfractionated (CAHF) and late-course accelerated hyperfractionated (LCAF) radiotherapy. Methods: Subjective and Objective Management Analysis (SOMA) scale, Symptom Checklist 90 (SCL-90) and Life Satisfaction Index A (LSIA) questionnaire were mailed to the long survivors in both CAHF and LCAF groups to assess the long-term quality of life including symptoms, psychological status and life satisfaction. Results: There was no significant difference between the two groups in the score of quality of life such as late radiation reaction, SCL-90 and LSI-A. Conclusions: 1. It is reasonable to assess the quality of life with these scales for esophageal carcinoma patients treated with radiotherapy, 2. Preliminary results demonstrate that there is no significant difference in long-term quality of life between the CAHF and LCAF radiotherapy groups, 3. Methods of evaluating the long-term quality of life for esophageal carcinoma patients treated with radiotherapy needs further investigation, preferably involving more patients and setting on control arm

  3. Preoperative concurrent CBDCA chemotherapy and accelerated hyperfractionated radiotherapy for squamous cell carcinoma of the maxillary region

    International Nuclear Information System (INIS)

    Omura, Ken; Harada, Hiroyuki; Suzuki, Haruhiko; Takeuchi, Yosuke; Hatano, Kazuo; Togawa, Takashi

    2001-01-01

    Between 1994 and 2000, 28 patients with T3/T4 squamus cell carcinoma of the maxillary region (maxillary sinus, 22; maxillary gingiva, 4; maxillary bone, 1; buccal mucosa, 1) had accelerated hyperfractionated radiotherapy combined with simultaneous CBDCA chemotherapy preoperatively, at Chiba Cancer Center Hospital. The protocol consisted of combined therapy with accelerated hyperfractionated irradiation of 1.6 Gy, twice a day, to a total dose of 32.0-51.2 Gy and concurrent intra-arterial or intravenous infusion of CBDCA 20-30 mg/body/day for a cumulative total dose of 270-480 mg. After completion of the preoperative combined therapy, the clinical CR rate was 17.9%, and the good PR·CR rate was 32.1%. According to the initial findings and response to the combined therapy, all patients had maxillectomy (subtotal, 3; total, 16; extended, 9) 4 weeks after completion of the preoperative combined therapy. Postoperatively, the complete pathologic response (Ohboshi and Shimozato's classification, grade III and IV) rate was 28.6%. And the actuarial local control rate was 85.7%, with a mean follow-up of 46.2 months. Based on these results, we believe this preoperative therapy with CBDCA chemotherapy and accelerated hyperfractionated radiation is a significant choice as treatment for squamous cell cancer of the maxillary region. (author)

  4. Preoperative concurrent CBDCA chemotherapy and accelerated hyperfractionated radiotherapy for squamous cell carcinoma of the maxillary region

    Energy Technology Data Exchange (ETDEWEB)

    Omura, Ken; Harada, Hiroyuki [Tokyo Medical and Dental Univ. (Japan). Graduate School; Suzuki, Haruhiko; Takeuchi, Yosuke; Hatano, Kazuo; Togawa, Takashi

    2001-11-01

    Between 1994 and 2000, 28 patients with T3/T4 squamus cell carcinoma of the maxillary region (maxillary sinus, 22; maxillary gingiva, 4; maxillary bone, 1; buccal mucosa, 1) had accelerated hyperfractionated radiotherapy combined with simultaneous CBDCA chemotherapy preoperatively, at Chiba Cancer Center Hospital. The protocol consisted of combined therapy with accelerated hyperfractionated irradiation of 1.6 Gy, twice a day, to a total dose of 32.0-51.2 Gy and concurrent intra-arterial or intravenous infusion of CBDCA 20-30 mg/body/day for a cumulative total dose of 270-480 mg. After completion of the preoperative combined therapy, the clinical CR rate was 17.9%, and the good PR{center_dot}CR rate was 32.1%. According to the initial findings and response to the combined therapy, all patients had maxillectomy (subtotal, 3; total, 16; extended, 9) 4 weeks after completion of the preoperative combined therapy. Postoperatively, the complete pathologic response (Ohboshi and Shimozato's classification, grade III and IV) rate was 28.6%. And the actuarial local control rate was 85.7%, with a mean follow-up of 46.2 months. Based on these results, we believe this preoperative therapy with CBDCA chemotherapy and accelerated hyperfractionated radiation is a significant choice as treatment for squamous cell cancer of the maxillary region. (author)

  5. Safety and adverse events of neoadjuvant short-course hyperfractionated accelerated radiotherapy (SC-HART) for rectal cancer

    International Nuclear Information System (INIS)

    Doi, Hiroshi; Kamikonya, Norihiko; Hirota, Shozo; Beppu, Naohito; Yanagi, Hidenori

    2014-01-01

    We presented good tolerability and short-term outcomes of neoadjuvant short-course hyperfractionated accelerated radiotherapy (SC-HART; 25 Gy in 10 fractions for 5 days) combined with chemotherapy in a total of 73 patients with lower rectal cancer. Age, gender, tumor differentiation, and the type of surgery seemed to have no apparent effects on toxicity of SC-HART. SC-HART appeared to have a good feasibility for use in further clinical trials. (author)

  6. Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator

    Science.gov (United States)

    Bol, G. H.; Hissoiny, S.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2012-03-01

    The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In this paper, a fast IMRT optimization system is described which combines a GPU-based Monte Carlo dose calculation engine for online beamlet generation and a fast inverse dose optimization algorithm. Tightly conformal IMRT plans are generated for four phantom cases and two clinical cases (cervix and kidney) in the presence of the magnetic fields of 0 and 1.5 T. We show that for the presented cases the beamlet generation and optimization routines are fast enough for online IMRT planning. Furthermore, there is no influence of the magnetic field on plan quality and complexity, and equal optimization constraints at 0 and 1.5 T lead to almost identical dose distributions.

  7. Acute tolerance of hyperfractionated accelerated total body irradiation

    International Nuclear Information System (INIS)

    Latz, D.; Schraube, P.; Wannenmacher, M.

    1996-01-01

    Background: Acute side effects of total body irradiation lead to intense molestations of the patients. Therefore, it is desirable to take measures to reduce these side effects. In a retrospective study the frequency on acute side effects of a hyperfractionated accelerated total body irradiation was assessed and compared to frequencies of other exposure schedules published in the literature. Additionally the influence of ondansetron on the frequency of nausea and vormiting was investigated. Patients and Method: From 1989 to 1992, 76 patients (47 male, 29 female; median age 38 years) underwent total body irradiation before autologeous bone marrow transplantation. They received 3 daily doses of 1.20 Gy each every 4 h on 4 successive days to a total dose of 14,40 Gy. Thirty-nine patients received 3x8 mg (daily, intravenous or per os) ondansetron during the whole course of irradiation. Results: The most relevant side effects were nausea and vomiting. Patients, who did not receive ondansetron (n=37) showed a nausea and emesis rate of 73%. With ondansetron (n=39) nausea and emesis were reduced to 38%. Also the grade of severity of these side effects was reduced. Conclusions: Ondansetron proved to be an effective medicament for relieving nausea and vormiting during total body irradiation. The results obtained are in concordance with those published in the literature. (orig.) [de

  8. Protocol for the isotoxic intensity modulated radiotherapy (IMRT) in stage III non-small cell lung cancer (NSCLC): a feasibility study.

    Science.gov (United States)

    Haslett, Kate; Franks, Kevin; Hanna, Gerard G; Harden, Susan; Hatton, Matthew; Harrow, Stephen; McDonald, Fiona; Ashcroft, Linda; Falk, Sally; Groom, Nicki; Harris, Catherine; McCloskey, Paula; Whitehurst, Philip; Bayman, Neil; Faivre-Finn, Corinne

    2016-04-15

    The majority of stage III patients with non-small cell lung cancer (NSCLC) are unsuitable for concurrent chemoradiotherapy, the non-surgical gold standard of care. As the alternative treatment options of sequential chemoradiotherapy and radiotherapy alone are associated with high local failure rates, various intensification strategies have been employed. There is evidence to suggest that altered fractionation using hyperfractionation, acceleration, dose escalation, and individualisation may be of benefit. The MAASTRO group have pioneered the concept of 'isotoxic' radiotherapy allowing for individualised dose escalation using hyperfractionated accelerated radiotherapy based on predefined normal tissue constraints. This study aims to evaluate whether delivering isotoxic radiotherapy using intensity modulated radiotherapy (IMRT) is achievable. Isotoxic IMRT is a multicentre feasibility study. From June 2014, a total of 35 patients from 7 UK centres, with a proven histological or cytological diagnosis of inoperable NSCLC, unsuitable for concurrent chemoradiotherapy will be recruited. A minimum of 2 cycles of induction chemotherapy is mandated before starting isotoxic radiotherapy. The dose of radiation will be increased until one or more of the organs at risk tolerance or the maximum dose of 79.2 Gy is reached. The primary end point is feasibility, with accrual rates, local control and overall survival our secondary end points. Patients will be followed up for 5 years. The study has received ethical approval (REC reference: 13/NW/0480) from the National Research Ethics Service (NRES) Committee North West-Greater Manchester South. The trial is conducted in accordance with the Declaration of Helsinki and Good Clinical Practice (GCP). The trial results will be published in a peer-reviewed journal and presented internationally. NCT01836692; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence

  9. A phase ii study of concurrent accelerated hyperfractionated radiotherapy and carboplatin/oral etoposide for elderly patients with stage iii non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Jeremic, Branislav; Shibamoto, Yuta; Milicic, Biljana; Milisavljevic, Slobodan; Nikolic, Nebojsa; Dagovic, Aleksandar; Aleksandrovic, Jasna; Radosavljevic-Asic, Gordana

    1999-01-01

    Purpose: To investigate feasibility, toxicity, and efficacy of accelerated hyperfractionated radiation therapy and concurrent carboplatin/oral etoposide in elderly (> 70 years) patients with stage III non-small-cell lung cancer. Methods and Materials: Between January 1988 and June 1993, a total of 58 patients entered a phase II study. Carboplatin (400 mg/m 2 ) was given intravenously on days 1 and 29, and etoposide (50 mg/m 2 ) was given orally on days 1-21 and 29-42. Accelerated hyperfractionated radiotherapy was administered starting on day 1, with a total dose of 51 Gy in 34 fractions over 3.5 weeks. Results: In 55 evaluable patients, the complete response rate was 27% and the overall response rate was 65%. For the 55 patients, the median survival time was 10 months, and the 1-, 2-, and 5-year survival rates were 45%, 24%, and 9.1%, respectively. The median time until relapse was 8 months and the 1-, 2-, and 5-year relapse-free survival rates were 45%, 20%, and 9.1%, respectively. The median time to local recurrence was 14 months and the 5-year local control rate was 13%; the median time to distant metastasis was 18 months and the 5-year distant metastasis-free rate was 15%. Hematological, esophageal, and bronchopulmonary acute grade 3 or 4 toxicities were observed in 22%, 7%, and 4% of the patients, respectively. There was no grade 5 toxicity or late grade ≥ 3 toxicity. Conclusion: Concurrent accelerated hyperfractionated radiotherapy and carboplatin/oral etoposide produced relatively low and acceptable toxicity. The survival results appeared to be comparable to those obtained in nonelderly patients with stage III non-small-cell lung cancer treated by full-dose radiation

  10. IMRT dose fractionation for head and neck cancer: Variation in current approaches will make standardisation difficult

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Kean F. (Academic Dept. of Radiation Oncology, Univ. of Manchester, Manchester (United Kingdom)); Fowler, Jack F. (Dept. of Human Oncology and Medical Physics, Univ. of Wisconsin, Wisconsin (United States)); Sykes, Andrew J.; Yap, Beng K.; Lee, Lip W.; Slevin, Nick J. (Dept. of Clinical Oncology, Christie Hospital NHS Foundation Trust, Manchester (United Kingdom))

    2009-04-15

    Introduction. Altered fractionation has demonstrated clinical benefits compared to the conventional 2 Gy/day standard of 70 Gy. When using synchronous chemotherapy, there is uncertainty about optimum fractionation. IMRT with its potential for Simultaneous Integrated Boost (SIB) adds further to this uncertainty. This survey will examine international practice of IMRT fractionation and suggest possible reasons for diversity in approach. Material and methods. Fourteen international cancer centres were surveyed for IMRT dose/fractionation practised in each centre. Results. Twelve different types of dose fractionation were reported. Conventional 70-72 Gy (daily 2 Gy/fraction) was used in 3/14 centres with concurrent chemotherapy while 11/14 centres used altered fractionation. Two centres used >1 schedule. Reported schedules and number of centres included 6 fractions/week DAHANCA regime (3), modest hypofractionation (=2.2 Gy/fraction) (3), dose-escalated hypofractionation (=2.3 Gy/fraction) (4), hyperfractionation (1), continuous acceleration (1) and concomitant boost (1). Reasons for dose fractionation variability include (i) dose escalation; (ii) total irradiated volume; (iii) number of target volumes; (iv) synchronous systemic treatment; (v) shorter overall treatment time; (vi) resources availability; (vii) longer time on treatment couch; (viii) variable GTV margins; (ix) confidence in treatment setup; (x) late tissue toxicity and (xi) use of lower neck anterior fields. Conclusions. This variability in IMRT fractionation makes any meaningful comparison of treatment results difficult. Some standardization is needed particularly for design of multi-centre randomized clinical trials.

  11. Preoperative hyperfractionated accelerated radiotherapy and radical surgery in advanced head and neck cancer: A prospective phase II study

    International Nuclear Information System (INIS)

    Lindholm, Paula; Valavaara, Ritva; Aitasalo, Kalle; Kulmala, Jarmo; Laine, Juhani; Elomaa, Liisa; Sillanmaeki, Lauri; Minn, Heikki; Grenman, Reidar

    2006-01-01

    Background and purpose: To evaluate whether preoperative hyperfractionated accelerated radiotherapy (RT) combined with major radical surgery is feasible and successful in the treatment of advanced primary head and neck cancer. Patients and methods: Ninety four patients with histologically confirmed head and neck squamous cell cancer (HNSCC) in the oral cavity (41/96; 43%), supraglottis (14/96; 15%), glottis (5/96; 5%), oropharynx (16/96; 17%), nasal cavity/paranasal sinuses (8/96; 8%), nasopharynx (3/96; 3%), hypopharynx (7/96; 7%) and two (2%) with unknown primary tumour and large cervical lymph nodes entered into the study. 21/96 patients (22%) had stage II, 17/96 (18%) stage III and 58/96 patients (60%) stage IV disease. The patients received preoperative hyperfractionated RT 1.6 Gy twice a day, 5 days a week to a median tumour dose of 63 Gy with a planned break for 11 days (median) after the median dose of 37 Gy. Then, after a median of 27 days the patients underwent major radical surgery of the primary tumour and metastatic lymph nodes including reconstructions with pedicled or microvascular free flaps when indicated as a part of the scheduled therapy. 12/96 patients had only ipsilateral or bilateral neck dissections. Results: After a median follow-up time of 37.2 mos 77/96 (80.2%) patients had complete locoregional control. All but 2 patients had complete histological remission after surgery. 40/96 pts were alive without disease, two of them after salvage surgery. 32/96 patients had relapsed; 15 had locoregional and 13 distant relapses, 4 patients relapsed both locoregionally and distantly. Fifty patients have died; 29 with locoregional and/or distant relapse, eight patients died of second malignancy, and 19 had intercurrent diseases. Disease-specific and overall survival at 3 years was 67.7 and 51%, respectively. Acute grade three mucosal reactions were common, but transient and tolerable. Late grade 3-4 adverse effects were few. Conclusions: Preoperative

  12. COMPARISON OF CONVENTIONAL RADIATIOTHERAPY AND ACCELERATED HYPERFRACTIONATED RADIATIOTHERAPY IN CHEMORADIATION TREATMENT FOR SMALL CELL LUNG CANCER

    Directory of Open Access Journals (Sweden)

    I. A. Gulidov

    2013-01-01

    Full Text Available The 5-year treatment outcomes of 69 patients with stage IIA–IIIA locally advanced small cell lung cancer have been presented. Accelerated hyperfractionated radiotherapy was administered in the uneven daily dose fractionation (single dose of 1 + 1,5 Gy with a 5–6hour interval to a total dose of 60–70 Gy depending on the health status and lung function. The complete response was achieved in 13 (42 % patients, the median survival was 28 months and the 5-year survival rate was 26,2 %. Grade III lung and pericardium toxicities (according to RTOG toxicity scale were observed in 3,2 % and 6,5 % of patients, respectively. No grade III–IV radiation-induced blood and esophageal damages were found.

  13. The Quality Control of Intensity Modulated Radiation Therapy (IMRT for ONCOR Siemens Linear Accelerators Using Film Dosimetry

    Directory of Open Access Journals (Sweden)

    Keyvan Jabbari

    2012-03-01

    Full Text Available Introduction Intensity Modulated Radiation Therapy (IMRT has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various steps of planning and quality control of Siemens linear accelerators for IMRT, using film dosimetry. This article in addition to review of the techniques, discusses the details of experiments and possible sources of errors which are not mentioned in the protocols and other references. Materials and Methods This project was carried out in Isfahan Milad hospital which has two Siemens ONCOR linear accelerators. Both accelerators are equipped with Multi-Leaf Collimators (MLC which enables us to perform IMRT delivery in the step-and-shoot method. The quality control consists of various experiments related to the sections of radiation therapy. In these experiments, the accuracy of some components such as treatment planning system, imaging device (CT, MLC, control system of accelerator, and stability of the output are evaluated. The dose verification is performed using film dosimetry method. The films were KODAK-EDR2, which were calibrated before the experiments. One of the important steps is the comparison of the calculated dose with planning system and the measured dose in experiments. Results The results of the experiments in various steps have been acceptable according to the standard protocols. The calibration of MLC and evaluation of the leakage through the leaves of MLC was performed by using the film dosimetry and visual check. In comparison with calculated and measured dose, more that 80% of the points have to be in agreement within 3% of the value. In our experiments, between 85 and 90% of the points had such an agreement with IMRT delivery. Conclusion

  14. Altered fractionated radiotherapy has a survival benefit for head and neck cancers. Is it true?

    International Nuclear Information System (INIS)

    Hatano, Kazuo; Sakai, Mitsuhiro; Araki, Hitoshi; Doi, Katsuyuki; Asano, Takanori; Fujikawa, Akira

    2007-01-01

    There was a significant survival benefit with altered fractionated radiotherapy, corresponding to an absolute benefit of 3.4% at 5 years. The benefit was significantly higher with hyperfractionated radiotherapy (8% at 5 years) than with accelerated radiotherapy (2% with accelerated fractionation without total dose reduction and 1.7% with total dose reduction at 5 years). The effect was greater for the primary tumor than for nodal disease. The effect was also more pronounced in younger patients and in those with good performance status. Hyperfractionation seemed to yield a more consistent advantage for survival than accelerated fractionated radiotherapy. However, accelerated radiotherapy might be associated with higher non-cancer related death. We have to evaluate whether the benefit of hyperfractionated radiotherapy versus standard radiotherapy persists when combined with concomitant chemotherapy and the benefit of intensity-modulated radiation therapy (IMRT) compared with altered fractionation. (author)

  15. Late course accelerated hyperfractionated radiotherapy of nasopharyngeal carcinoma (LCAF)

    International Nuclear Information System (INIS)

    He Xiayun; Liu Taifu; He Shaoqin; Huan Sulan; Pan Ziqiang

    2007-01-01

    Background and purpose: To study the efficacy of late course accelerated fractionated (LCAF) radiotherapy in the treatment of nasopharyngeal carcinoma (NPC). The end-points were local control, radiation-induced complications, and factors influencing survival. Patients and methods: Between December 1995 and April 1998, 178 consecutive NPC patients were admitted for radiation treatment. The radiation beam used was 60 Co γ or 6 MV X rays. For the first two-thirds of the treatment, two daily fractions of 1.2 Gy were given to the primary lesion, with an interval of ≥6 h, 5 days per week to a total dose of 48 Gy/40 fractions, over a period of 4 weeks. For the last third of the treatment, i.e., beginning the 5th week of treatment, an accelerated hyperfractionated schedule was carried out. The dose per fraction was increased to 1.5 Gy, 2 fractions per day with an interval of ≥6 h, the total dose for this part of the protocol was 30 Gy/20 fractions over 2 weeks. Thus the total dose was 78 Gy in 60 fractions in 6 weeks. Results: All patients completed the treatment. Acute mucositis: none in 2 cases, Grade 1 in 43 cases, Grade 2 in 78 cases, Grade 3 in 52 cases, and Grade 4 in 3 cases. Local control rate: the 5 year nasopharyngeal local control rate was 87.7%, and the cervical lymph nodes local control rate was 85.7%. The 5-year distant metastasis rate was 26.1%, and 5 year survivals were 67.9%, 16 (9%) patients had radiation-induced cranial nerve palsy, 7(4%) patients had temporal lobe or brainstem damage. Conclusions: With this treatment schedule, patients' tolerance was good, local control and 5 year survivals were better than conventional fractionation schedules, and radiation-related late complications did not increase, as 5-year survival rates of conventional fractionation radiotherapy were only 58%. Randomized clinical trials are being carried out to further confirm the efficacy of LCAF for nasopharyngeal carcinoma

  16. A meta-analysis of hyperfractionated and accelerated radiotherapy and combined chemotherapy and radiotherapy regimens in unresected locally advanced squamous cell carcinoma of the head and neck

    Directory of Open Access Journals (Sweden)

    Budach V

    2006-01-01

    Full Text Available Abstract Background Former meta-analyses have shown a survival benefit for the addition of chemotherapy (CHX to radiotherapy (RT and to some extent also for the use of hyperfractionated radiation therapy (HFRT and accelerated radiation therapy (AFRT in locally advanced squamous cell carcinoma (SCC of the head and neck. However, the publication of new studies and the fact that many older studies that were included in these former meta-analyses used obsolete radiation doses, CHX schedules or study designs prompted us to carry out a new analysis using strict inclusion criteria. Methods Randomised trials testing curatively intended RT (≥60 Gy in >4 weeks/>50 Gy in Results Thirty-two trials with a total of 10 225 patients were included into the meta-analysis. An overall survival benefit of 12.0 months was observed for the addition of simultaneous CHX to either CFRT or HFRT/AFRT (p Conclusion RT combined with simultaneous 5-FU, cisplatin, carboplatin, and mitomycin C as single drug or combinations of 5-FU with one of the other drugs results in a large survival advantage irrespective the employed radiation schedule. If radiation therapy is used as single modality, hyperfractionation leads to a significant improvement of overall survival. Accelerated radiation therapy alone, especially when given as split course radiation schedule or extremely accelerated treatments with decreased total dose, does not increase overall survival.

  17. Hyperfractionated-accelerated radiotherapy followed by radical surgery in locally advanced tumors of the oral cavity

    International Nuclear Information System (INIS)

    Hoeller, U.; Biertz, I.; Tribius, S.; Alberti, W.; Flinzberg, S.; Schmelzle, R.

    2006-01-01

    Purpose: to evaluate the outcome of hyperfractionated-accelerated radiotherapy and subsequent planned primary tumor resection and radical neck dissection in locally advanced tumors of the oral cavity. Patients and Methods: this retrospective analysis evaluates 126 subsequent patients who were treated between 1988 and 1997 for locally advanced tumors of the oral cavity (with extension into the oropharynx in 17 patients), 34 (27%) AJCC stage III and 92 (73%) stage IV. Primary tumor and nodal metastases were irradiated with 1.4 Gy bid to a median total dose of 72.8 Gy (range 58.8-75.6 Gy). Then, planned radical surgery of the primary site according to the initial tumor extent and cervical nodes was performed. Median follow-up of living patients was 6 years (range 1-11 years). Results: 4 weeks after radiotherapy, 14 patients (11%) had complete tumor remission, 92 (73%) partial remission, 15 (12%) no change, and five (4%) progressive disease. Complete resection was achieved in 117 (93%) patients (nine incomplete resections). 5-year locoregional control rate was 62 ± 9%, overall survival 36 ± 9%. Surgery-related morbidity occurred in 42 patients (33%; mainly delayed wound healing and fistulae), overall severe treatment-related morbidity in 46 patients (36%). 24/84 relapse-free patients (29%) required a percutaneous gastrostomy or nasal tube ≥ 1 year after therapy. Conclusion: in this study, the outcome of combined curative radiotherapy and planned surgery of the primary tumor and neck nodes was comparable to reported results of hyperfractionated radiotherapy with or without salvage surgery of the neck nodes with respect to locoregional control and overall survival. Planned surgery carries a substantial risk of morbidity and seems to offer no benefit in comparison to salvage surgery of the neck nodes only. Therefore, salvage surgery is preferred. (orig.)

  18. Split Course Hyperfractionated Accelerated Radio-Chemotherapy (SCHARC) for patients with advanced head and neck cancer: Influence of protocol deviations and hemoglobin on overall survival, a retrospective analysis

    OpenAIRE

    Stadler, Peter; Putnik, Kurt; Kreimeyer, Thore; Sprague, Lisa D; Koelbl, Oliver; Schäfer, Christof

    2006-01-01

    Abstract Background The advantage of hyperfractionated accelerated radiation therapy for advanced head and neck cancer has been reported. Furthermore, randomized trials and meta-analyses have confirmed the survival benefit of additional chemotherapy to radiotherapy. We retrospectively analyzed the efficiency and toxicity of the Regensburg standard therapy protocol "SCHARC" and the overall survival of our patients. Methods From 1997 to 2004, 64 patients suffering from advanced head and neck ca...

  19. A phase II study of hyperfractionated accelerated radiotherapy (HART) after induction cisplatin (CDDP) and vinorelbine (VNR) for stage III Non-small-cell lung cancer (NSCLC)

    International Nuclear Information System (INIS)

    Ishikura, Satoshi; Ohe, Yuichiro; Nihei, Keiji; Kubota, Kaoru; Kakinuma, Ryutaro; Ohmatsu, Hironobu; Goto, Koichi; Niho, Seiji; Nishiwaki, Yutaka; Ogino, Takashi

    2005-01-01

    Purpose: The purpose was to assess the feasibility and efficacy of hyperfractionated accelerated radiotherapy (HART) after induction chemotherapy for Stage III non-small-cell lung cancer. Methods and materials: Treatment consisted of 2 cycles of cisplatin 80 mg/m 2 on Day 1 and vinorelbine 25 mg/m 2 on Days 1 and 8 every 3 weeks followed by HART, 3 times a day (1.5, 1.8, 1.5 Gy, 4-h interval) for a total dose of 57.6 Gy. Results: Thirty patients were eligible. Their median age was 64 years (range, 46-73 years), 24 were male, 6 were female, 8 had performance status (PS) 0, 22 had PS 1, 9 had Stage IIIA, and 21 had Stage IIIB. All but 1 patient completed the treatment. Common grade ≥3 toxicities during the treatment included neutropenia, 25; infection, 5; esophagitis, 5; and radiation pneumonitis, 3. The overall response rate was 83%. The median survival was 24 months (95% confidence interval [CI], 13-34 months), and the 2-year overall survival was 50% (95% CI, 32-68%). The median progression-free survival was 10 months (95% CI, 8-20 months). Conclusion: Hyperfractionated accelerated radiotherapy after induction of cisplatin and vinorelbine was feasible and promising. Future investigation employing dose-intensified radiotherapy in combination with chemotherapy is needed

  20. Accelerated Hyperfractionated Radiotherapy for Locally Advanced Uterine Cervix Cancers

    International Nuclear Information System (INIS)

    Seo, Young Seok; Cho, Chul Koo; Yoo, Seong Yul

    2008-01-01

    To assess the efficacy of the use of accelerated hyperfractionated radiotherapy (AHRT) for locally advanced uterine cervix cancers. Between May 2000 and September 2002, 179 patients were identified with FIGO stage IIB, IIIB, and IVA cancers. Of the 179 patients, 45 patients were treated with AHRT (AHRT group) and 134 patients were treated with conventional radiotherapy (CRT group), respectively. Patients undergoing the AHRT regimen received a dose of 30 Gy in 20 fractions (1.5 Gyx2 fractions/day) to the whole pelvis. Subsequently, with a midline block, we administered a parametrial boost with a dose of 20 Gy using 2 Gy fractions. Patients also received two courses of low-dose-rate brachytherapy, up to a total dose of 85∼90 Gy to point A. In the CRT group of patients, the total dose to point A was 85∼90 Gy. The overall treatment duration was a median of 37 and 66 days for patients that received AHRT and CRT, respectively. Statistical analysis was calculated by use of the Kaplan-Meier method, the log-rank test, and Chi-squared test. For patients that received cisplatin-based concurrent chemotherapy and radiotherapy, the local control rate at 5 years was 100% and 79.2% for the AHRT and CRT group of patients, respectively (p=0.028). The 5-year survival rate for patients with a stage IIB bulky tumor was 82.6% and 62.1% for the AHRT group and CRT group, respectively (p=0.040). There was no statistically significant difference for severe late toxicity between the two groups (p=0.561). In this study, we observed that treatment with AHRT with concurrent chemotherapy allows a significant advantage of local control and survival for locally advanced uterine cervix cancers

  1. The role of accelerated hyperfractionated radiotherapy in the treatment of inoperable non-small cell lung cancer: a controlled clinical trial

    International Nuclear Information System (INIS)

    Reinfuss, M.; Kowalska, T.; Glinski, C.

    2000-01-01

    Radiotherapy remains the basic form of treatment in cases of non-small cell lung cancer (NSCLC) but there still exist controversies concerning optimal radiotherapy regimen and in particular, the total dose and fractionation schedules. To prove whether the question: if using an unconventional dose fractionation regimen (accelerated hyperfractionation) could improve the results of palliative teleradiotherapy patients with NSCLC. Between 1997 and 2000 in the Cancer Centre in Cracow (COOK) a controlled clinical trial was conducted in a group of 150 patients with locally advanced (III Deg) inoperable and unsuitable for radical radiotherapy NSCLC, with no major symptoms of the disease. In 76 patients conventionally fractionated radiotherapy was performed - 50 Gy in 25 fractions during 5 weeks (CF). 74 patients were irradiated twice a day (AHF); the dose per fraction was 1.25 Gy and the minimum interval between fractions - 6 hours. The total dose was 50 Gy in 40 fractions during 26 days. The probability of 12 months survival was 47.4% in the CF arm and 45.9% in the AHF arm; the probability of 24 months survival was 16.2% and 15.8%, respectively. In all 76 patients in CF arm the treatment was carried out in prescribed time without breaks. Out of 74 patients in the A HF group 8 (10,8%) did not complete the treatment and 2 of then died in 3rd and 4th week of treatment. The use of accelerated hyperfractionation does not improve the results of palliative teleradiotherapy in patients with locally advanced NSCLC without severe symptoms related to intrathoracic tumor. The treatment of choice in this group of patients os conventionally fractionated radiotherapy with a total dose of 50 Gy in 25 fractions in 5 week of treatment. (author)

  2. The financial impact of the incorporation of IMRT and RapidArc™ techniques on shielding calculation of a linear accelerator

    International Nuclear Information System (INIS)

    Santos, Maira R.; Silveira, Thiago B.; Garcia, Paulo L.; Trindade, Cassia; Martins, Lais P.; Batista, Delano V.S.

    2013-01-01

    Given the new methodology introduced in the shielding calculation due to recent modulated techniques in radiotherapy treatment, it became necessary to evaluate the impact of changes in the accelerator routine using such techniques. Based on a group of 30 patients from the National Cancer Institute (INCA) the workload multiplier factors for intensity modulated radiotherapy (IMRT factor) and for RapidArc™ (RA factor) were established. Four different routines in a 6 MV generic accelerator were proposed to estimate the impact of these modified workloads in the building cost of the secondary barriers. The results indicate that if 50% of patients are treating with IMRT, the secondary barrier becomes 14,1% more expensive than the barrier calculated for conformal treatments exclusive. While RA, in the same proportion, leads to a barrier only 3,7% more expensive. Showing that RA can, while reducing treatment time, increase the proportion of patients treated with modulation technique, without increasing the cost of the barrier, when compared with IMRT. (author)

  3. Continuous hyperfractionated accelerated radiotherapy (chart) in localized cancer of the esophagus

    International Nuclear Information System (INIS)

    Powell, Melanie E.B.; Hoskin, Peter J.; Saunders, Michele I.; Foy, Christopher J.W.; Dische, Stanley

    1997-01-01

    Purpose: To assess the efficacy and toxicity of continuous hyperfractionated accelerated radiotherapy (CHART) in locoregional control compared with a historical group of patients treated with conventionally fractionated radical radiotherapy. Methods and Materials: Between 1985 and 1994, 54 patients with localized esophageal cancer were treated with CHART. Twenty-eight patients received CHART alone (54 Gy in 36 fractions over 12 consecutive days) and 15 were given intravenous mitomycin C and cisplatin on days 10 and 13, respectively. Eleven patients received 40.5 Gy in 27 fractions over 9 days, followed by a single high-dose-rate intraluminal brachytherapy insertion of 15 Gy at 1 cm. Results: Acute toxicity was well tolerated and dysphagia was improved in 35 patients (65%), with 28 (52%) eating a normal diet by week 12. This compares with an improvement in dysphagia score in 72% of the conventionally treated group. The median duration of relief of dysphagia was 7.8 months (range 0-41.4) in the CHART group compared with 5.5 months (range 0-48) in the controls. Strictures developed in 29 patients (61%) and 18 were confirmed on biopsy to be due to recurrent disease. Median survival was 12 months (range 0.5-112) in the CHART group and 15 months (range 3.6-56) in the control patients. Conclusion: CHART is well tolerated and achieves a high rate of local control. Palliation in the short overall treatment time of esophageal cancer is an advantage in these patients whose median survival is only 12 months

  4. A randomized phase III study of accelerated hyperfractionation versus standard in patients with unresected brain metastases: a report of the radiation therapy oncology group (RTOG) 9104

    International Nuclear Information System (INIS)

    Murray, Kevin J.; Scott, Charles; Greenberg, Harvey M.; Emami, Bahman; Seider, Michael; Vora, Nayana L.; Olson, Craig; Whitton, Anthony; Movsas, Benjamin; Curran, Walter

    1997-01-01

    Purpose: To compare 1-year survival and acute toxicity rates between an accelerated hyperfractionated (AH) radiotherapy (1.6 Gy b.i.d.) to a total dose of 54.4 Gy vs. an accelerated fractionation (AF) of 30 Gy in 10 daily fractions in patients with unresected brain metastasis. Methods and Materials: The Radiation Therapy Oncology Group (RTOG) accrued 445 patients to a Phase III comparison of accelerated hyperfractionation vs. standard fractionation from 1991 through 1995. All patients had histologic proof of malignancy at the primary site. Brain metastasis were measurable by CT or MRI scan and all patients had a Karnofsky performance score (KPS) of at least 70 and a neurologic function classification of 1 or 2. For AH, 32 Gy in 20 fractions over 10 treatment days (1.6 Gy twice daily) was delivered to the whole brain. A boost of 22.4 Gy in 14 fractions was delivered to each lesion with a 2-cm margin. Results: The average age in both groups was 60 years; nearly two-thirds of all patients had lung primaries. Of the 429 eligible and analyzable patients, the median survival time was 4.5 months in both arms. The 1-year survival rate was 19% in the AF arm vs. 16% in the AH arm. No difference in median or 1-year survival was observed among patients with solitary metastasis between treatment arms. Recursive partitioning analysis (RPA) classes have previously been identified and patients with a KPS of 70 or more, a controlled primary tumor, less than 65 years of age, and brain metastases only (RPA class I), had a 1-year survival of 35% in the AF arm vs. 25% in the AH arm (p = 0.95). In a multivariate model, only age, KPS, extent of metastatic disease (intracranial metastases only vs. intra- and extracranial metastases), and status of primary (controlled vs. uncontrolled) were statistically significant (at p < 0.05). Treatment assignment was not statistically significant. Overall Grade III or IV toxicity was equivalent in both arms, and one fatal toxicity at 44 days secondary

  5. The hyperfractionation in the oropharynx carcinomas treatment: stages III and IV

    International Nuclear Information System (INIS)

    Pinto, L.H.J.

    1990-01-01

    From April 1986 until May 1989. 112 patients with stages III and IV oropharynx carcinomas were included in a protocol comparing the use of Hyperfractionation and Conventional Fractionation. The doses were 6600 rad in 33 fractions of 200 rad for the conventional fractionation and 7040 rad in 64 fractions, two fractions of 110 rad per day for the hyperfractionation. As of January 1990 an analysis was performed in 98 patients, with a median follow-up of 14 months. The probability of complete responses in the oropharynx was 74%, with 84% for the hyperfractionation and 64% for the conventional fractionation ( p < 0,05). Survival was improved in 42 months for those patients treated with hyperfractionation: 27% versus 8% (p < 0,05). In patients with lesions out of the base of the tongue and in those with Karnofsky performance status of 50%, 60% and 70%, survival was improved with the use of hyperfractionation (p = 0,02 and p 0,006 respectively. The study demonstrates the superiority of hyperfractionation over the classical fractionation in the treatment of patients with carcinoma of the oropharynx. (author)

  6. To hyperfractionate or not to hyperfractionate-Is it really a question?

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Merlano, Marco C

    2016-01-01

    Despite technical advances the last decade, patients with HPV/p16 negative head and neck cancer (being smokers and having affected performance and co-morbidities), still have a poor outcome after treatment. Hyperfractionated radiotherapy with concurrent cisplatin might be a reasonable way to purs...

  7. Hyperfractionation in carcinoma of the cervix: tumor control and late bowel complications

    International Nuclear Information System (INIS)

    Viswanathan, Faith Rangad; Varghese, Cherian; Peedicayil, Abraham; Lakshmanan, Jeyaseelan; Narayan, Viswanathan Perungulam

    1999-01-01

    Purpose: Hyperfractionation has been advocated to improve local tumor control by increasing radiation dose without increasing late normal tissue complications. The aim of this study was to determine if hyperfractionation decreased late bowel complications. Methods and Materials: Thirty patients with Stage II and III cervical cancer were randomized to receive either hyperfractionation or conventional fractionation. Patients were followed for 5 years and monitored for tumor control, recurrence, and bowel complications. The relative risks of tumor control and bowel complications were computed at 1 year and 5 years of follow-up. Kaplan-Meier survival curves were plotted to determine probabilities of being tumor-free and bowel complication-free. Results: There were 15 patients in each group. At 1 year of follow-up, 2 patients in the hyperfractionation group (13%) and 7 patients in the conventional treatment group (45%) had tumor (relative risk [RR] 0.3; 95% confidence interval [CI] 0.1, 1.1; p = 0.054). Delayed bowel complications were seen in 8 patients in the hyperfractionation group and 1 patient in the conventional treatment group (RR 7.5; 95% CI 1.1, 52; p = 0.014). At 5 years, 2 patients in the hyperfractionation group and 8 patients in the conventional treatment group had tumor (RR 0.3; 95% CI 0.1, 1.1; p = 0.04). Delayed bowel complications (Grades 2 and 3) occurred in 9 women in the hyperfractionation group and 2 patients in the conventional group (RR 5.4; 95% CI 1.5, 19.5; p 0.0006). Kaplan-Meier analysis showed that the hyperfractionation group had significantly more bowel complications over the 5 years of follow-up (p 0.024). Conclusion: Hyperfractionation may result in better tumor control both at 1 year and at 5 years following treatment of cervical cancer. However, hyperfractionation could lead to increased late bowel complications and must be used judiciously in the treatment of cervical cancer

  8. Hyperfractionated Accelerated Radiotherapy (HART) for Anaplastic Thyroid Carcinoma: Toxicity and Survival Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dandekar, Prasad [Head and Neck/Thyroid Unit, Royal Marsden NHS Foundation Trust, Sutton, Surrey (United Kingdom); Harmer, Clive; Barbachano, Yolanda [Department of Clinical Research and Development, Royal Marsden NHS Foundation Trust, Sutton, Surrey (United Kingdom); Rhys-Evans, Peter; Harrington, Kevin; Nutting, Christopher [Head and Neck-Thyroid Unit, Royal Marsden NHS Foundation Trust, Chelsea, London (United Kingdom); Newbold, Kate [Head and Neck/Thyroid Unit, Royal Marsden NHS Foundation Trust, Sutton, Surrey (United Kingdom); Consultant Clinical Oncologist, Royal Marsden NHS Foundation Trust, Chelsea, London (United Kingdom)

    2009-06-01

    Purpose: Anaplastic thyroid carcinoma (ATC) is one of the most aggressive cancers, and the current protocol of hyperfractionated accelerated radiotherapy was initiated to improve survival while limiting toxicities. Methods and Materials: All patients with ATC from 1991 to 2002 were accrued and received megavoltage radiotherapy from the mastoid processes to the carina up to 60 Gy in twice-daily fractions of 1.8 and 2 Gy, 6 hours apart. Results: Thirty-one patients were accrued with a median age of 69 years, and 55% were women. Debulking was performed in 26%, and total thyroidectomy, in 6%, whereas 68% received radical radiotherapy alone. Local control data were available for 27 patients: 22% had a complete response, 26% had a partial response, 15% showed progressive disease, and 37% showed static disease. Median overall survival for all 31 patients was 70 days (95% confidence interval, 40-99). There was no significant difference in median survival between patients younger (70 days) and older than 70 years (42 days), between men (70 days) and women (49days), and between patients receiving postoperative radiotherapy (77 days) and radical radiotherapy alone (35 days). Grade III or higher skin erythema was seen in 56% patients; desquamation in 21%; dysphagia in 74%; and esophagitis in 79%. Conclusion: The current protocol failed to offer a significant survival benefit, was associated with severe toxicities, and thus was discontinued. There is a suggestion that younger patients with operable disease have longer survival, but this would require a larger study to confirm it.

  9. Hyperfractionated accelerated radiotherapy with concomitant integrated boost of 70-75 Gy in 5 weeks for advanced head and neck cancer. A phase I dose escalation study

    Energy Technology Data Exchange (ETDEWEB)

    Cvek, J.; Skacelikova, E.; Otahal, B.; Halamka, M.; Feltl, D. [University Hospital Ostrava (Czech Republic). Dept. of Oncology; Kubes, J. [University Hospital Bulovka, Prague (Czech Republic). Dept. of Radiation Oncology; Kominek, P. [University Hospital Ostrava (Czech Republic). Dept. of Otolaryngology

    2012-08-15

    Background and purpose: The present study was performed to evaluate the feasibility of a new, 5-week regimen of 70-75 Gy hyperfractionated accelerated radiotherapy with concomitant integrated boost (HARTCIB) for locally advanced, inoperable head and neck cancer. Methods and materials: A total of 39 patients with very advanced, stage IV nonmetastatic head and neck squamous cell carcinoma (median gross tumor volume 72 ml) were included in this phase I dose escalation study. A total of 50 fractions intensity-modulated radiotherapy (IMRT) were administered twice daily over 5 weeks. Prescribed total dose/dose per fraction for planning target volume (PTV{sub tumor}) were 70 Gy in 1.4 Gy fractions, 72.5 Gy in 1.45 Gy fractions, and 75 Gy in 1.5 Gy fractions for 10, 13, and 16 patients, respectively. Uninvolved lymphatic nodes (PTV{sub uninvolved}) were irradiated with 55 Gy in 1.1 Gy fractions using the concomitant integrated boost. Results: Acute toxicity was evaluated according to the RTOG/EORTC scale; the incidence of grade 3 mucositis was 51% in the oral cavity/pharynx and 0% in skin and the recovery time was {<=} 9 weeks for all patients. Late toxicity was evaluated in patients in complete remission according to the RTOG/EORTC scale. No grade 3/4 late toxicity was observed. The 1-year locoregional progression-free survival was 50% and overall survival was 55%. Conclusion: HARTCIB (75 Gy in 5 weeks) is feasible for patients deemed unsuitable for chemoradiation. Acute toxicity was lower than predicted from radiobiological models; duration of dysphagia and confluent mucositis were particularly short. Better conformity of radiotherapy allows the use of more intensive altered fractionation schedules compared with older studies. These results suggest that further dose escalation might be possible when highly conformal techniques (e.g., stereotactic radiotherapy) are used.

  10. ACCELERATED HYPERFRACTIONATED RADIOTHERAPY IN THE TREATMENT FOR INOPERABLE, LOCALLY ADVANCED GASTRIC CANSER

    Directory of Open Access Journals (Sweden)

    S. S. Litinskiy

    2015-01-01

    Full Text Available Purpose: to compare survival of patients with locally advanced inoperable gastric cancer (LAIGC, receiving accelerated hyperfractionated (AHF or conventionally fractionated (CF radiation therapy (RT. Methods and Materials. Between November 1993 and March 2010, 137 patients with LAIGC receiving CF (2 Gy daily or AHF (1.3 Gy b.i.d. to total at least 50 Gy RT in combination or without chemotherapy were retrospectively selected from the hospital database of Arkhangelsk clinical oncological dispensary. Overall survival (OS assessed using actuarial analysis, Kaplan – Meier method and Cox regression. results. The CF and AHF groups were 102 and 35 patients, respectively. Median follow-up time for all patients was 12 years. By the time of analysis 123 (90 % patients of all cohort died. Median, 7-year survival were 24 (95 % confidence intervals (CI, 17–31 vs 16 (95 % CI, 11–21 months, hazard ratio (HR=0.71 (95 % CI, 0.46–1.06, р=0.097; and 19 % (95 % CI 8–34 % vs 6% (95 % CI 2–13 % in the AHF and CF groups, respectively. In multivariate OS model the difference decreased to HR=0.87 (95 % CI, 0.49–1.55. The location of the tumor in median third (HR=0.60, 95 % CI, 0.37–0.99 in refer to upper third was the only independent factor influencing survival.  There was no influence of the total dose in chosen level on survival. conclusion. Our retrospective shows trend towards better OS for those LAIGC patients receiving RT in AHF regimen compared to CF. The prospective randomized study with conformal radiation technics is necessary to confirm these findings.

  11. The financial impact of the incorporation of IMRT and RapidArc™ techniques on shielding calculation of a linear accelerator; O impacto financeiro da incorporacao das tecnicas de IMRT e RapidArc™ no calculo de blindagem de um acelerador linear

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maira R.; Silveira, Thiago B.; Garcia, Paulo L.; Trindade, Cassia; Martins, Lais P.; Batista, Delano V.S., E-mail: mairafisica@gmail.com [Instituto Nacional do Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2013-08-15

    Given the new methodology introduced in the shielding calculation due to recent modulated techniques in radiotherapy treatment, it became necessary to evaluate the impact of changes in the accelerator routine using such techniques. Based on a group of 30 patients from the National Cancer Institute (INCA) the workload multiplier factors for intensity modulated radiotherapy (IMRT factor) and for RapidArc™ (RA factor) were established. Four different routines in a 6 MV generic accelerator were proposed to estimate the impact of these modified workloads in the building cost of the secondary barriers. The results indicate that if 50% of patients are treating with IMRT, the secondary barrier becomes 14,1% more expensive than the barrier calculated for conformal treatments exclusive. While RA, in the same proportion, leads to a barrier only 3,7% more expensive. Showing that RA can, while reducing treatment time, increase the proportion of patients treated with modulation technique, without increasing the cost of the barrier, when compared with IMRT. (author)

  12. High-dose, hyperfractionated, accelerated radiotherapy using a concurrent boost for the treatment of nonsmall cell lung cancer: unusual toxicity and promising early results

    International Nuclear Information System (INIS)

    King, Stephen C.; Acker, Jeffrey C.; Kussin, Peter S.; Marks, Lawrence B.; Weeks, Kenneth J.; Leopold, Kenneth A.

    1996-01-01

    Purpose: The treatment of nonsmall cell lung cancer (NSCLC) with conventional radiotherapy (RT) results in inadequate local tumor control and survival. We report results of a Phase II trial designed to treat patients with a significantly increased total dose administered in a reduced overall treatment time using a hyperfractionated, accelerated treatment schedule with a concurrent boost technique. Methods and Materials: A total of 49 patients with unresectable Stage IIIA/IIIB (38 patients) or medically inoperable Stage I/II (11 patients) NSCLC were prospectively enrolled in this protocol. Radiation therapy was administered twice daily, 5 days/week with > 6 h between each treatment. The primary tumor and adjacent enlarged lymph nodes were treated to a total dose of 73.6 Gy in 46 fractions of 1.6 Gy each. Using a concurrent boost technique, electively irradiated nodal regions were simultaneously treated with a dose of 1.25 Gy/fraction for the first 36 fractions to a total dose of 45 Gy. Results: Median survival for the entire group of 49 patients is 15.3 months. Actuarial survival at 2 years is 46%: 60% for 11 Stage I/II patients, 55% for 21 Stage IIIA patients, and 26% for 17 Stage IIIB patients. The actuarial rate of freedom from local progression at 2 years is 64% for the entire group of 49 patients: 62% for Stage I/II patients, 70% for Stage IIIA patients, and 55% for Stage IIIB patients. Patients who underwent serial bronchoscopic reevaluation (4 Stage I/II, 8 Stage IIIA, and 6 Stage IIIB) have an actuarial rate of local control of 71% at 2 years. The median total treatment time was 32 days. Nine of 49 patients (18%) experienced Grade III acute esophageal toxicity. The 2-year actuarial risk of Grade III or greater late toxicity is 30%. The 2-year actuarial rate of severe-late pulmonary and skin-subcutaneous toxicity is 20% and 15%, respectively. Conclusion: This treatment regimen administers a substantially higher biologically effective dose compared with

  13. Angiosarcoma after breast-conserving therapy: experience with hyperfractionated radiotherapy

    International Nuclear Information System (INIS)

    Feigenberg, Steven J.; Price Mendenhall, Nancy; Reith, John D.; Ward, Jon R.; Copeland, Edward M.

    2002-01-01

    Purpose: To report our promising results of hyperfractionated radiotherapy (RT) in conjunction with surgery for angiosarcoma occurring after breast-conserving therapy for early-stage breast cancer. Methods and Materials: Since 1997, 3 cases of angiosarcoma after breast-conserving therapy have been managed at the University of Florida. The histologic specimens in each case were reviewed and graded by one of us (J.D.R.). Results: Explosive growth of discolored skin lesions coincident with histologic evidence of angiosarcoma characterized all 3 cases but was preceded by a fairly indolent period (almost 2 years) of atypical vascular hyperplasia in 2 patients. All 3 patients were treated initially with radical surgery for the angiosarcoma, but extensive recurrences were noted within 1 to 2 months of surgery. Because of the extremely rapid growth noted before and after surgery, hyperfractionated RT was used. Two of the patients underwent planned resection after RT, and neither specimen demonstrated any evidence of high-grade angiosarcoma. All 3 patients were alive without any recurrent disease 22, 38, and 39 months after treatment. Conclusions: Hyperfractionated irradiation appears to be effective treatment for rapidly proliferating angiosarcoma. For previously untreated angiosarcoma, we now recommend hyperfractionated RT followed by surgery to enhance disease control and remove as much reirradiated tissue as possible

  14. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    OpenAIRE

    Daniel L Saenz; Bhudatt R Paliwal; John E Bayouth

    2014-01-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This ...

  15. Classical spreading-fractionation, hyperfractionation, hypofractionation: let us attempt to be practical

    International Nuclear Information System (INIS)

    Cosset, J.M.; Baillet, F.

    1986-01-01

    The so-called classical spreading-fractionation (5 sessions of 2 Gy per week) was elaborated originally by the first generation of radiotherapists at the beginning of the century. It is a remarkable fact that even today the most up-to-date radiobiologists are in agreement that this regimen usually represents the best possible compromise between antitumoral efficacy and toxicity to healthy tissue. Hyperfractionation is still in the clinical trial stage with the aim of defining its precise place in clinical practice. At the present there is only one formal indication apart from within this framework: tumors with very rapid times for doubling in size, since hyperfractionation alone can deliver a high dose in a short period of time (accelerated treatment). Hypofractionation can be highly recommended for palliative treatment, because of its simplicity and efficacy. In contrast, when large size tumours (particularly digestive) are treated in patients with an elevated expected rate of recovery, this technique may provoke late complications and should, a priori, be avoided. For small size tumours however (ENT, breast) it would appear possible to elaborate hypofractio - nation protocols allowing local control to a similar degree to that obtained with the classical regimen, without significantly increasing late complications, on the condition that radiation parameters (dose, spread, fractionation) be cho - sen with the greatest care [fr

  16. A Phase I Dose-Escalation Study (ISIDE-BT-1) of Accelerated IMRT With Temozolomide in Patients With Glioblastoma

    International Nuclear Information System (INIS)

    Morganti, Alessio G.; Balducci, Mario; Salvati, Maurizio; Esposito, Vincenzo; Romanelli, Pantaleo; Ferro, Marica; Calista, Franco; Digesu, Cinzia; Macchia, Gabriella; Ianiri, Massimo; Deodato, Francesco; Cilla, Savino; Piermattei, Angelo M.P.; Valentini, Vincenzo; Cellini, Numa; Cantore, Gian Paolo

    2010-01-01

    Purpose: To determine the maximum tolerated dose (MTD) of fractionated intensity-modulated radiotherapy (IMRT) with temozolomide (TMZ) in patients with glioblastoma. Methods and Materials: A Phase I clinical trial was performed. Eligible patients had surgically resected or biopsy-proven glioblastoma. Patients started TMZ (75 mg/day) during IMRT and continued for 1 year (150-200 mg/day, Days 1-5 every 28 days) or until disease progression. Clinical target volume 1 (CTV1) was the tumor bed ± enhancing lesion with a 10-mm margin; CTV2 was the area of perifocal edema with a 20-mm margin. Planning target volume 1 (PTV1) and PTV2 were defined as the corresponding CTV plus a 5-mm margin. IMRT was delivered in 25 fractions over 5 weeks. Only the dose for PTV1 was escalated (planned dose escalation: 60 Gy, 62.5 Gy, 65 Gy) while maintaining the dose for PTV2 (45 Gy, 1.8 Gy/fraction). Dose limiting toxicities (DLT) were defined as any treatment-related nonhematological adverse effects rated as Grade ≥3 or any hematological toxicity rated as ≥4 by Radiation Therapy Oncology Group (RTOG) criteria. Results: Nineteen consecutive glioblastoma were treated with step-and-shoot IMRT, planned with the inverse approach (dose to the PTV1: 7 patients, 60 Gy; 6 patients, 62.5 Gy; 6 patients, 65 Gy). Five coplanar beams were used to cover at least 95% of the target volume with the 95% isodose line. Median follow-up time was 23 months (range, 8-40 months). No patient experienced DLT. Grade 1-2 treatment-related neurologic and skin toxicity were common (11 and 19 patients, respectively). No Grade >2 late neurologic toxicities were noted. Conclusion: Accelerated IMRT to a dose of 65 Gy in 25 fractions is well tolerated with TMZ at a daily dose of 75 mg.

  17. Angiosarcoma after breast-conserving therapy: long-term outcomes with hyperfractionated radiotherapy.

    Science.gov (United States)

    Palta, Manisha; Morris, Christopher G; Grobmyer, Stephen R; Copeland, Edward M; Mendenhall, Nancy P

    2010-04-15

    With breast-conserving therapy (BCT) as the standard of care for patients with noninvasive and early stage invasive breast cancer, a small incidence of post-BCT angiosarcoma has emerged. The majority of therapeutic interventions have been unsuccessful. To the authors' knowledge, there is no consensus in the medical literature to date regarding the treatment of this malignancy. The current study was conducted to report the long-term outcomes of a novel approach using hyperfractionated and accelerated radiotherapy (HART) for angiosarcoma developing after BCT. The authors retrospectively reviewed the outcomes of 14 patients treated with HART with or without surgery at the University of Florida between November 1997 and March 2006 for angiosarcoma that developed after BCT. At the time of last follow-up, 9 patients had remained continuously without evidence of disease for a median of 61 months after HART (range, 36-127 months). Five patients had further manifestations of angiosarcoma after HART at a median of 1 month (range, 1-28 months): 3 with progressive pulmonary and/or mediastinal disease that was likely present before HART and 2 with local or regional disease extension. Progression-free survival rates for the 14 patients at 2 years and 5 years were 71% and 64%, respectively. The overall and cause-specific survival rates were both 86% at 2 years and 5 years. To the best of the authors' knowledge, HART with or without subsequent surgery, as documented in the current series, is the first approach to provide a high rate of local control, disease-free survival, and overall survival after the development of post-BCT angiosarcoma. The authors believe the success noted with this approach is related to both the hyperfractionation and acceleration of the RT. (c) 2010 American Cancer Society.

  18. Stereotactic IMRT using a MMLC

    International Nuclear Information System (INIS)

    Hoban, P.; Short, R.; Biggs, D.; Rose, A.; Smee, R.; Schneider, M.

    2001-01-01

    Full text: The leaf width of the multileaf collimator (MLC) used for intensity modulated radiotherapy (IMRT ) largely determines the resolution of the intensity maps that define the entire profile of each beam. In turn it is this resolution, and consequently the achievable degree of beam modulation, that determines the ability to conform the 3D dose distribution to complex target volumes. As such, the leaf width is of more importance than in fixed-field MLC treatments where only the beam edges are affected.A Radionics micro-multileaf collimator (MMLC) with 4 mm leaf width, attached to a Siemens Primus linear accelerator, is in use for stereotactic IMRT at PbWH. Treatment planning is performed with the XPlan system including an integrated IMRT module. Cases treated have so far been with conventional fractionation, including both malignant and benign cranial lesions. Meningiomas in particular often require a complex dose distribution because of their en-plaque nature and/or proximity to the brainstem. Stereotactic localisation and fixation is with the Gill-Thomas-Cosman head-ring or Head and Neck localiser. Cases are typically planned both for fixed-field treatment and IMRT, with IMRT being used if significant benefit is seen. IMRT treatment with the Siemens MLC is also an option. A quality assurance system has been set up, including a flowchart/checklist and phantom dosimetry using TLDs. As expected, treatment plans show IMRT with the MMLC to consistently be the best option dosimetrically. In particular, for a given target coverage there is always better sparing of nearby organs at risk (OARs) with MMLC rather than MLC-based IMRT. Adjustments such as the inclusion of a margin around the target volume or an increase in the penalty for target underdosage improve coverage for MLC plans but generally at the expense of increased OAR involvement. MMLC IMRT treatments commonly require 30-50 fields and can be delivered in approximately 10-15 minutes using an autosequence

  19. Intracellular recovery - basis of hyperfractionation

    International Nuclear Information System (INIS)

    Hagen, U.; Guttenberger, R.; Kummermehr, J.

    1988-01-01

    The radiobiological basis fo a hyperfractionated radiation therapy versus conventional fractionation with respect to therapeutic gain, i.e., improved normal tissue sparing for the same level of tumour cell inactivation, will be presented. Data on the recovery potential of various tissues as well as the kinetics of repair will be given. The problem of incomplete repair with short irradiation intervals will be discussed. (orig.) [de

  20. Intensified hyperfractionated accelerated radiotherapy limits the additional benefit of simultaneous chemotherapy--results of a multicentric randomized German trial in advanced head-and-neck cancer.

    Science.gov (United States)

    Staar, S; Rudat, V; Stuetzer, H; Dietz, A; Volling, P; Schroeder, M; Flentje, M; Eckel, H E; Mueller, R P

    2001-08-01

    To demonstrate the efficacy of radiochemotherapy (RCT) as the first choice of treatment for advanced unresectable head-and-neck cancer. To prove an expected benefit of simultaneously given chemotherapy, a two-arm randomized study with hyperfractionated accelerated radiochemotherapy (HF-ACC-RCT) vs. hyperfractionated accelerated radiotherapy (HF-ACC-RT) was initiated. The primary endpoint was 1-year survival with local control (SLC). Patients with Stage III and IV (UICC) unresectable oro- and hypopharyngeal carcinomas were randomized for HF-ACC-RCT with 2 cycles of 5-FU (600 mg/m(2)/day)/carboplatinum (70 mg/m(2)) on days 1--5 and 29--33 (arm A) or HF-ACC-RT alone (arm B). In both arms, there was a second randomization for testing the effect of prophylactically given G-CSF (263 microg, days 15--19) on mucosal toxicity. Total RT dose in both arms was 69.9 Gy in 38 days, with a concomitant boost regimen (weeks 1--3: 1.8 Gy/day, weeks 4 and 5: b.i.d. RT with 1.8 Gy/1.5 Gy). Between July 1995 and May 1999, 263 patients were randomized (median age 56 years; 96% Stage IV tumors, 4% Stage III tumors). This analysis is based on 240 patients: 113 patients with RCT and 127 patients with RT, qualified for protocol and starting treatment. There were 178 oropharyngeal and 62 hypopharyngeal carcinomas. Treatment was tolerable in both arms, with a higher mucosal toxicity after RCT. Restaging showed comparable nonsignificant different CR + PR rates of 92.4% after RCT and 87.9% after RT (p = 0.29). After a median observed time of 22.3 months, l- and 2-year local-regional control (LRC) rates were 69% and 51% after RCT and 58% and 45% after RT (p = 0.14). There was a significantly better 1-year SLC after RCT (58%) compared with RT (44%, p = 0.05). Patients with oropharyngeal carcinomas showed significantly better SLC after RCT (60%) vs. RT (40%, p = 0.01); the smaller group of hypopharyngeal carcinomas had no statistical benefit of RCT (p = 0.84). For both tumor locations

  1. A meta-analysis of hyperfractionated and accelerated radiotherapy and combined chemotherapy and radiotherapy regimens in unresected locally advanced squamous cell carcinoma of the head and neck

    International Nuclear Information System (INIS)

    Budach, W; Hehr, T; Budach, V; Belka, C; Dietz, K

    2006-01-01

    Former meta-analyses have shown a survival benefit for the addition of chemotherapy (CHX) to radiotherapy (RT) and to some extent also for the use of hyperfractionated radiation therapy (HFRT) and accelerated radiation therapy (AFRT) in locally advanced squamous cell carcinoma (SCC) of the head and neck. However, the publication of new studies and the fact that many older studies that were included in these former meta-analyses used obsolete radiation doses, CHX schedules or study designs prompted us to carry out a new analysis using strict inclusion criteria. Randomised trials testing curatively intended RT (≥60 Gy in >4 weeks/>50 Gy in <4 weeks) on SCC of the oral cavity, oropharynx, hypopharynx, and larynx published as full paper or in abstract form between 1975 and 2003 were eligible. Trials comparing RT alone with concurrent or alternating chemoradiation (5-fluorouracil (5-FU), cisplatin, carboplatin, mitomycin C) were analyzed according to the employed radiation schedule and the used CHX regimen. Studies comparing conventionally fractionated radiotherapy (CFRT) with either HFRT or AFRT without CHX were separately examined. End point of the meta-analysis was overall survival. Thirty-two trials with a total of 10 225 patients were included into the meta-analysis. An overall survival benefit of 12.0 months was observed for the addition of simultaneous CHX to either CFRT or HFRT/AFRT (p < 0.001). Separate analyses by cytostatic drug indicate a prolongation of survival of 24.0 months, 16.8 months, 6.7 months, and 4.0 months, respectively, for the simultaneous administration of 5-FU, cisplatin-based, carboplatin-based, and mitomycin C-based CHX to RT (each p < 0.01). Whereas no significant gain in overall survival was observed for AFRT in comparison to CFRT, a substantial prolongation of median survival (14.2 months, p < 0.001) was seen for HFRT compared to CFRT (both without CHX). RT combined with simultaneous 5-FU, cisplatin, carboplatin, and mitomycin C as

  2. Preventing radiation retinopathy with hyperfractionation

    International Nuclear Information System (INIS)

    Monroe, Alan T.; Bhandare, Niranjan; Morris, Christopher G.; Mendenhall, William M.

    2005-01-01

    Purpose: The purpose of this study was to determine factors associated with the development of radiation retinopathy in a large series of patients with head-and-neck cancer. In particular, we addressed whether the use of hyperfractionated radiation therapy was effective in reducing the risk of retinopathy. Methods and materials: One hundred eighty-six patients received a significant dose to the retina as part of curative radiotherapy. Primary sites included: nasopharynx, 46; paranasal sinus, 64; nasal cavity, 69; and palate, 7. Prescription doses varied depending on primary site and histology. Hyperfractionated (twice-daily) radiation was delivered to 42% of the patients in this study, typically at 1.10 to 1.20 Gy per fraction. The remainder were treated once-daily. Retinal doses were determined from computerized dosimetry plans when available. For all other patients, retinal doses were retrospectively calculated using reconstructed off-axis dosimetry taken from contours through the center of the globes. Retinal dose was defined as the minimum dose received by at least 25% of the globe. The median retinal dose was 56.85 Gy. Patients were followed for a median of 7.6 years. Results: Thirty-one eyes in 30 patients developed radiation retinopathy, resulting in monocular blindness in 25, bilateral blindness in 1, and decreased visual acuity in 4. The median time to the diagnosis of retinopathy was 2.6 years (range, 11 months to 5.3 years). The actuarial incidence of developing radiation retinopathy was 20% at both 5 and 10 years. The incidence of developing ipsilateral blindness due to retinopathy was 16% at 5 years and 17% at 10 years. Site-specific incidences varied considerably, with ethmoid sinus (9 of 25, 36%), nasal cavity (13 of 69, 19%), and maxillary sinus (6 of 35, 17%) being the most common sites associated with radiation retinopathy. Three of 72 patients (4%) receiving retinal doses less than 50 Gy developed retinopathy. Higher retinal doses resulted in a

  3. Randomized phase III trial of concurrent chemoradiotherapy vs accelerated hyperfractionation radiotherapy in locally advanced head and neck cancer

    International Nuclear Information System (INIS)

    Chitapanarux, Imjai; Kamnerdsupaphon, Pimkhuan; Pukanhapan, Nantaka; Tharavichitkul, Ekkasit; Vongtama, Roy

    2013-01-01

    The aim of this study was to compare the efficacy and safety of concurrent chemoradiotherapy (CCRT) vs accelerated hyperfractionation with concomitant boost (CCB) as a primary treatment for patients with Stage III-IV squamous cell carcinoma of head and neck (SCCHN). A total of 85 non-metastatic advanced SCCHN patients were accrued from January 2003 to December 2007. Of these, 48 and 37 patients received CCRT and CCB, respectively. The patients were randomized to receive either three cycles of carboplatin and 5-fluorouracil plus conventional radiotherapy (CCRT, 66 Gy in 6.5 weeks) or hybrid accelerated radiotherapy (CCB, 70 Gy in 6 weeks). The primary endpoint was determined by locoregional control rate. The secondary endpoints were overall survival and toxicity. With a median follow-up of 43 months (range, 3-102), the 5-year locoregional control rate was 69.6% in the CCRT arm vs 55.0% in the CCB arm (P = 0.184). The 5-year overall survival rate was marginally significantly different (P = 0.05): 76.1% in the CCRT arm vs 63.5% in the CCB arm. Radiotherapy treatment interruptions of more than three days were 60.4% and 40.5% in the CCRT arm and CCB arm, respectively. The median total treatment time was 55.5 days in the CCRT arm and 49 days in the CCB arm. The rate of Grade 3 - 4 acute mucositis was significantly higher in the CCB arm (67.6% vs 41.7%, P = 0.01), but no high grade hematologic toxicities were found in the CCB arm (27.2% vs 0%). CCRT has shown a trend of improving outcome over CCB irradiation in locoregionally advanced head and neck cancer. (author)

  4. Gemcitabine, cisplatin, and hyperfractionated accelerated radiotherapy for locally advanced non-small cell lung cancer.

    Science.gov (United States)

    Zwitter, Matjaz; Kovac, Viljem; Smrdel, Uros; Strojan, Primoz

    2006-09-01

    Due to potent radiosensitization and potential serious or fatal toxicity, concurrent gemcitabine and irradiation should only be applied within clinical trials. We here present experience from a phase I-II clinical trial for patients with locally advanced non-small cell lung cancer (NSCLC) treated with hyperfractionated accelerated radiotherapy and concurrent low-dose gemcitabine. Eligible patients had locally advanced inoperable NSCLC without pleural effusion, Eastern Cooperative Oncology Group performance status 0-1, were chemotherapy naïve and had no previous radiotherapy to the chest, and had adequate hematopoietic, liver, and kidney function. Routine brain computed tomography was not performed, and positron emission tomography/computed tomography was not available. Treatment consisted of three parts: induction chemotherapy with gemcitabine and cisplatin in standard doses, local treatment with concurrent chemotherapy and radiotherapy, and consolidation chemotherapy. Patients were irradiated with opposed AP-PA and oblique fields, using 2.5-D treatment planning. Although corrections for inhomogeneous tissue were made, volume of total lung receiving > or =20 Gy (V20) could not be determined. The trial started as phase I, aimed to determine the dose-limiting toxicity and maximal tolerated dose (MTD) for concurrent hyperfractionated radiotherapy (1.4 Gy twice daily) and gemcitabine 55 mg/m twice weekly as a radiosensitizer. Phase II of the trial then continued at the level of MTD. Twenty-eight patients with NSCLC, nine patients with stage IIIA, 16 patients with IIIB, and three patients with an inoperable recurrence after previous surgery, entered the trial. The first 12 patients entered Phase I of the trial at the initial level of 42 Gy in 30 fractions in 3 weeks. Dose-limiting toxicity was acute esophagitis; 47.6 Gy in 34 fractions in 3.5 weeks was the MTD for this regimen of concurrent chemotherapy and radiotherapy. In phase II of the trial, this dose was applied

  5. Measurement of the dosimetric parameters for low monitor units in step-and-shoot IMRT delivered by Siemens Artiste linear accelerators; Medida de los parametros dosimetricos para bajo numero de unidades monitor en IMRT segmentada estatica administrada por aceleradores lineales Siemens Artiste

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Lopez Fernandez, A.; Saez Beltran, M.; Martin Martin, G.; Alonso Iracheta, L.

    2012-07-01

    Absorbed dose linearity and beam stability, both for low monitor units, are important factors for ensuring planned dose delivery in step-and-shoot IMRT. For Siemens Artiste linear accelerators, under IMRT stable irradiation conditions and for a single segment of 20 cm x 20 cm field size, the linearity of the absorbed dose with the monitor units, field flatness and symmetry have been measured for the range between 1 and 10 monitor units. We have found that absorbed dose linearity with monitor units is within 2% down to 2 monitor units and it is about 9% for 1 monitor unit. Flatness and symmetry values show variations within 1% down to 2 monitor units and increase by 9% for lower values. Using our monitor unit distribution per segment in IMRT we estimate that the uncertainty in absorbed dose for a whole treatment due to these factors is less than 1% (k= 3). (Author) 13 refs.

  6. Intensified hyperfractionated accelerated radiotherapy limits the additional benefit of simultaneous chemotherapy--results of a multicentric randomized German trial in advanced head-and-neck cancer

    International Nuclear Information System (INIS)

    Staar, Susanne; Rudat, Volker; Stuetzer, Hartmut; Dietz, Andreas; Volling, Peter; Schroeder, Michael; Flentje, Michael; Eckel, Hans Edmund; Mueller, Rolf-Peter

    2001-01-01

    Purpose: To demonstrate the efficacy of radiochemotherapy (RCT) as the first choice of treatment for advanced unresectable head-and-neck cancer. To prove an expected benefit of simultaneously given chemotherapy, a two-arm randomized study with hyperfractionated accelerated radiochemotherapy (HF-ACC-RCT) vs. hyperfractionated accelerated radiotherapy (HF-ACC-RT) was initiated. The primary endpoint was 1-year survival with local control (SLC). Methods and Materials: Patients with Stage III and IV (UICC) unresectable oro- and hypopharyngeal carcinomas were randomized for HF-ACC-RCT with 2 cycles of 5-FU (600 mg/m 2 /day)/carboplatinum (70 mg/m 2 ) on days 1-5 and 29-33 (arm A) or HF-ACC-RT alone (arm B). In both arms, there was a second randomization for testing the effect of prophylactically given G-CSF (263 μg, days 15-19) on mucosal toxicity. Total RT dose in both arms was 69.9 Gy in 38 days, with a concomitant boost regimen (weeks 1-3: 1.8 Gy/day, weeks 4 and 5: b.i.d. RT with 1.8 Gy/1.5 Gy). Between July 1995 and May 1999, 263 patients were randomized (median age 56 years; 96% Stage IV tumors, 4% Stage III tumors). Results: This analysis is based on 240 patients: 113 patients with RCT and 127 patients with RT, qualified for protocol and starting treatment. There were 178 oropharyngeal and 62 hypopharyngeal carcinomas. Treatment was tolerable in both arms, with a higher mucosal toxicity after RCT. Restaging showed comparable nonsignificant different CR + PR rates of 92.4% after RCT and 87.9% after RT (p=0.29). After a median observed time of 22.3 months, l- and 2-year local-regional control (LRC) rates were 69% and 51% after RCT and 58% and 45% after RT (p=0.14). There was a significantly better 1-year SLC after RCT (58%) compared with RT (44%, p=0.05). Patients with oropharyngeal carcinomas showed significantly better SLC after RCT (60%) vs. RT (40%, p=0.01); the smaller group of hypopharyngeal carcinomas had no statistical benefit of RCT (p=0.84). For both

  7. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    International Nuclear Information System (INIS)

    Wiezorek, Tilo; Schubert, Kai; Wagner, Daniela; Wendt, Thomas G; Brachwitz, Tim; Georg, Dietmar; Blank, Eyck; Fotina, Irina; Habl, Gregor; Kretschmer, Matthias; Lutters, Gerd; Salz, Henning

    2011-01-01

    Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx) using the following treatment planning systems (TPS) for rotational IMRT: Monaco (ELEKTA VMAT solution), Eclipse (Varian RapidArc solution) and HiArt for the helical tomotherapy (Tomotherapy). Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V 5Gy ). Additionally, the cumulative monitor units (MUs) and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V 5Gy values were lowest for the sliding window IMRT technique (3499 ccm) and largest for RapidArc (5480 ccm). The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. All IMRT delivery technologies with their associated TPS

  8. Hyperfractionation as an altered fractionation regimen in primary radiotherapy for squamous cell carcinoma of the larynx

    International Nuclear Information System (INIS)

    Krstevska, V.; Smichkoska, S.

    2006-01-01

    The aim of the study was to investigate the efficacy of hyperfractionation as altered fractionation treatment schedule in comparison with conventional fractionation in primary definitive radiotherapy for laryngeal squamous cell carcinoma. From March 1999 to December 2000, a group of 28 patients with previously untreated squamous cell carcinoma of the larynx were irradiated with conventional fractionation to to total doses of 66 to 70 Gy in 33 to 35 fraction/6.5 to 7 weeks, 2 Gy/fraction/day, 5 days/week. From January 2001 to June 2004, the other 27 patients with the same diagnosis, were treated prospectively with hyperfractionation receiving radiotherapy delivered at 1.2 Gy/fraction, twice daily, 5 days/week to 74.4 to 79.2 Gy/62 to fractions/6.2 to 7 weeks. Complete response rates after two mounts of radiotherapy completion were 78.6% (22 of 28) and 66.7% (18 of 27) in the conventional fractionation and hyperfractionation group, respectively (Fisher exact test; P=0.246). The two year loco-regional control rates were 61 .0%±18.1 (95% CI) in the conventional fractionation group and 45.0%±18.8 (95% CI) in the hyperfractionation group (long-rank test; P=0.075). Overall survival rate at two years was 71.0%±16.8 (95% CI) for the conventional group and 43.0%±18.7 (95% CI) for the hyperfractionation group (long- rank test; P=0.071). The absence of statistically significant differences either in loco-regional control or overall survival observed between the two treatment modalities suggested that hyperfractionation regimen was not more efficacious than conventionally fractionated radiotherapy for previously untreated carcinoma of the larynx.

  9. Serial histopathological changes in irradiated guinea pig lung receiving conventional fractionated and hyperfractionated irradiation

    International Nuclear Information System (INIS)

    Itoh, Satoshi; Inomata, Taisuke; Ogawa, Yasuhiro; Yoshida, Shoji; Sonobe, Hiroshi; Ohtsuki, Yuji

    1999-01-01

    The purpose of this study is to determine serial histopathological differences in guinea pig lungs receiving the same total dose as clinically used between conventional fractionated and hyperfractionated irradiation. The guinea pigs received 80 Gy in 40 daily fractions of 2 Gy each (conventional fractionation), 80 Gy in 80 fractions of 1 Gy each twice a day (hyperfractionation), 81 Gy in 27 daily fractions of 3 Gy each (conventional fractionation), or 81 Gy in 54 fractions of 1.5 Gy each twice a day (hyperfractionation). We evaluated the histopathological changes of irradiated guinea pig lungs at 1, 2, 3, 6, 9, and 12 months after irradiation. The guinea pig lungs that received 81 Gy in 27 daily fractions showed histopathological changes of inflammation including formation of lymph follicles after 6 months. The lungs which received 81 Gy in 54 fractions showed similar but slightly less pronounced changes than those that received 81 Gy in 27 daily fractions. The guinea pig lungs of other groups showed no histopathological changes during the observation period. In hyperfractionated irradiation the damage to the guinea pig lung is quantitatively less than that occurring as a result of conventional fractionated irradiation of the same total dose. (author)

  10. Serial histopathological changes in irradiated guinea pig lung receiving conventional fractionated and hyperfractionated irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Satoshi; Inomata, Taisuke; Ogawa, Yasuhiro; Yoshida, Shoji; Sonobe, Hiroshi; Ohtsuki, Yuji [Kochi Medical School, Nankoku (Japan)

    1999-05-01

    The purpose of this study is to determine serial histopathological differences in guinea pig lungs receiving the same total dose as clinically used between conventional fractionated and hyperfractionated irradiation. The guinea pigs received 80 Gy in 40 daily fractions of 2 Gy each (conventional fractionation), 80 Gy in 80 fractions of 1 Gy each twice a day (hyperfractionation), 81 Gy in 27 daily fractions of 3 Gy each (conventional fractionation), or 81 Gy in 54 fractions of 1.5 Gy each twice a day (hyperfractionation). We evaluated the histopathological changes of irradiated guinea pig lungs at 1, 2, 3, 6, 9, and 12 months after irradiation. The guinea pig lungs that received 81 Gy in 27 daily fractions showed histopathological changes of inflammation including formation of lymph follicles after 6 months. The lungs which received 81 Gy in 54 fractions showed similar but slightly less pronounced changes than those that received 81 Gy in 27 daily fractions. The guinea pig lungs of other groups showed no histopathological changes during the observation period. In hyperfractionated irradiation the damage to the guinea pig lung is quantitatively less than that occurring as a result of conventional fractionated irradiation of the same total dose. (author)

  11. Tomotherapy: IMRT and tomographic verification

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2000-01-01

    Full text: External beam radiation therapy delivery began around the turn of the century with the use of one or a few kilovoltage beams directed to the presumed site of the tumor. Often the treatment lasted until erythema dose was reached. Delivering the beams rotationally allowed the dose to be focused on the tumor and the skin to be spared. With the advent of megavoltage radiation therapy in the 1950's, using Co-60 teletherapy and betatrons, the treatment could once again be delivered from only a few beam directions and the dose to the skin would be kept below tolerance. Fields were shaped by lead blocks and later by custom-made blocks fabricated from low-melting temperature heavy metal. Linear accelerators did not fundamentally change the way in which radiation was delivered. It is likely that this delivery paradigm would not have changed had it not been for the advent of computers. Brahme and Cormack showed in the late 1980's that highly conformal treatments could be delivered with non-uniform intensity beams. At that time the only way in which the intensity modulated beams could be delivered was using custom-milled compensators. Fabricating and using compensators for multiple fields is time-consuming and labor-intensive. Serial tomotherapy was the first successful delivery method for IMRT and went back to the earlier practice of rotation therapy. The NOMOS Peacock system uses a binary (on-off) multileaf collimator (MLC) system to modulate a fan beam of radiation. It uses an optimization system to determine when leaves should be opened and closed. The system delivers two beam slices at once and the couch is indexed to the next slices by precisely translating the couch. This approach was first used in 1994 and to-date has treated several thousand patients. Prior to the advent of IMRT, accelerator vendors introduced the multileaf collimator (MLC) to provide field shaping without the need to fabricate custom blocking. Most new linear accelerator purchases today

  12. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    Directory of Open Access Journals (Sweden)

    Lutters Gerd

    2011-02-01

    Full Text Available Abstract Background Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Methods Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx using the following treatment planning systems (TPS for rotational IMRT: Monaco (ELEKTA VMAT solution, Eclipse (Varian RapidArc solution and HiArt for the helical tomotherapy (Tomotherapy. Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V5Gy. Additionally, the cumulative monitor units (MUs and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Results Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V5Gy values were lowest for the sliding window IMRT technique (3499 ccm and largest for RapidArc (5480 ccm. The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. Conclusions All

  13. Phase II Trial of Hyperfractionated Intensity-Modulated Radiation Therapy and Concurrent Weekly Cisplatin for Stage III and IVa Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Maguire, Patrick D.; Papagikos, Michael; Hamann, Sue; Neal, Charles; Meyerson, Martin; Hayes, Neil; Ungaro, Peter; Kotz, Kenneth; Couch, Marion; Pollock, Hoke; Tepper, Joel

    2011-01-01

    Purpose: To investigate a novel chemoradiation regimen designed to maximize locoregional control (LRC) and minimize toxicity for patients with advanced head-and-neck squamous cell carcinoma (HNSCC). Methods and Materials: Patients received hyperfractionated intensity modulated radiation therapy (HIMRT) in 1.25-Gy fractions b.i.d. to 70 Gy to high-risk planning target volume (PTV). Intermediate and low-risk PTVs received 60 Gy and 50 Gy, at 1.07, and 0.89 Gy per fraction, respectively. Concurrent cisplatin 33 mg/m 2 /week was started Week 1. Patients completed the Quality of Life Radiation Therapy Instrument pretreatment (PRE), at end of treatment (EOT), and at 1, 3, 6, 9, and 12 months. Overall survival (OS), progression-free (PFS), LRC, and toxicities were assessed. Results: Of 39 patients, 30 (77%) were alive without disease at median follow-up of 37.5 months. Actuarial 3-year OS, PFS, and LRC were 80%, 82%, and 87%, respectively. No failures occurred in the electively irradiated neck and there were no isolated neck failures. Head and neck QOL was significantly worse in 18 of 35 patients (51%): mean 7.8 PRE vs. 3.9 EOT. By month 1, H and N QOL returned near baseline (mean 6.2, SD = 1.7). The most common acute Grade 3+ toxicities were mucositis (38%), fatigue (28%), dysphagia (28%), and leukopenia (26%). Conclusions: Hyperfractionated IMRT with low-dose weekly cisplatin resulted in good LRC with acceptable toxicity and QOL. Lack of elective nodal failures despite very low dose per fraction has led to an attempt to further minimize toxicity by reducing elective nodal doses in our subsequent protocol.

  14. Clinical validation of an in-house EPID dosimetry system for IMRT QA at the Prince of Wales Hospital

    Science.gov (United States)

    Tyler, M.; Vial, P.; Metcalfe, P.; Downes, S.

    2013-06-01

    In this study a simple method using standard flood-field corrected Electronic Portal Imaging Device (EPID) images for routine Intensity Modulated Radiation Therapy (IMRT) Quality Assurance (QA) was investigated. The EPID QA system was designed and tested on a Siemens Oncor Impression linear accelerator with an OptiVue 1000ST EPID panel (Siemens Medical Solutions USA, Inc, USA) and an Elekta Axesse linear accelerator with an iViewGT EPID (Elekta AB, Sweden) for 6 and 10 MV IMRT fields with Step-and-Shoot and dynamic-MLC delivery. Two different planning systems were used for patient IMRT field generation for comparison with the measured EPID fluences. All measured IMRT plans had >95% agreement to the planning fluences (using 3 cGy / 3 mm Gamma Criteria) and were comparable to the pass-rates calculated using a 2-D diode array dosimeter.

  15. Clinical validation of an in-house EPID dosimetry system for IMRT QA at the Prince of Wales Hospital

    International Nuclear Information System (INIS)

    Tyler, M; Downes, S; Vial, P; Metcalfe, P

    2013-01-01

    In this study a simple method using standard flood-field corrected Electronic Portal Imaging Device (EPID) images for routine Intensity Modulated Radiation Therapy (IMRT) Quality Assurance (QA) was investigated. The EPID QA system was designed and tested on a Siemens Oncor Impression linear accelerator with an OptiVue 1000ST EPID panel (Siemens Medical Solutions USA, Inc, USA) and an Elekta Axesse linear accelerator with an iViewGT EPID (Elekta AB, Sweden) for 6 and 10 MV IMRT fields with Step-and-Shoot and dynamic-MLC delivery. Two different planning systems were used for patient IMRT field generation for comparison with the measured EPID fluences. All measured IMRT plans had >95% agreement to the planning fluences (using 3 cGy / 3 mm Gamma Criteria) and were comparable to the pass-rates calculated using a 2-D diode array dosimeter.

  16. Study on the possibility of using a 60 Co therapeutical unity in Intensity Modulated Radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Dantas, Samuel Cesar

    2009-06-01

    With the increasing advances in complex treatment techniques, there is a tendency to obtain more sophisticated equipment to deliver the dose. The use of 3D conformal radiotherapy is now routine in many radiotherapy facilities as well as the utilization of intensity modulated radiotherapy (IMRT). Both are usually implemented using linear accelerators equipped with multi leaves collimators, which create the conformity and the fluence distributions required. However, the complexity of increasingly sophisticated equipment, such as linear accelerators, requires a frequent quality control of their operation, as well as a detailed and constant maintenance. Even carrying out these procedures, the accelerators may present technical problems interrupting for a long time a treatment using the IMRT technique. Despite the clear practical and technological advantages that linear accelerators have on 60 Co irradiators, these devices occupy an important place in radiotherapy, mainly due to the low cost of equipment installation and maintenance when compared to those required by accelerators. Many radiotherapy facilities that work with IMRT have tele therapeutic isocentric 60 Co units. In principle, such equipment would be able to be used for treatment with IMRT using compensating blocks to modulate the beam. This study investigates this possibility and shows that it is feasible. The comparison of treatment plans of a head-and-neck cancer and other of a cancer of the central nervous system, based on a 60 Co irradiator and a Linac 2300 C/D, presented advantages for the 60 Co irradiator. Furthermore; the delivery of dose obtained with the two systems showed themselves equivalent when compared to their respective plans. (author)

  17. Neurocognitive outcome in brain metastases patients treated with accelerated-fractionation vs. accelerated-hyperfractionated radiotherapy: an analysis from Radiation Therapy Oncology Group Study 91-04

    International Nuclear Information System (INIS)

    Regine, W.F.; Scott, C.; Murray, K.; Curran, W.

    2001-01-01

    Purpose: To evaluate neurocognitive outcome as measured by the Mini-Mental Status Examination (MMSE) among patients with unresectable brain metastases randomly assigned to accelerated fractionation (AF) vs. accelerated hyperfractionated (AH) whole-brain radiation therapy (WBRT). Methods and Materials: The Radiation Therapy Oncology Group (RTOG) accrued 445 patients with unresectable brain metastases to a Phase III comparison of AH (1.6 Gy b.i.d. to 54.4 Gy) vs. AF (3 Gy q.d. to 30 Gy). All had a KPS of ≥ 70 and a neurologic function status of 0-2. Three hundred fifty-nine patients had MMSEs performed and were eligible for this analysis. Changes in the MMSE were analyzed according to criteria previously defined in the literature. Results: The median survival was 4.5 months for both arms. The average change in MMSE at 2 and 3 months was a drop of 1.4 and 1.1, respectively, in the AF arm as compared to a drop of 0.7 and 1.3, respectively, in the AH arm (p=NS). Overall, 91 patients at 2 months and 23 patients at 3 months had both follow-up MMSE and computed tomography/magnetic resonance imaging documentation of the status of their brain metastases. When an analysis was performed taking into account control of brain metastases, a significant effect on MMSE was observed with time and associated proportional increase in uncontrolled brain metastases. At 2 months, the average change in MMSE score was a drop of 0.6 for those whose brain metastases were radiologically controlled as compared to a drop of 1.9 for those with uncontrolled brain metastases (p=0.47). At 3 months, the average change in MMSE score was a drop of 0.5 for those whose brain metastases were radiologically controlled as compared to a drop of 6.3 for those with uncontrolled brain metastases (p=0.02). Conclusion: Use of AH as compared to AF-WBRT was not associated with a significant difference in neurocognitive function as measured by MMSE in this patient population with unresectable brain metastases and

  18. A two isocenter IMRT technique with a controlled junction dose for long volume targets

    International Nuclear Information System (INIS)

    Zeng, G G; Heaton, R K; Catton, C N; Chung, P W; O'Sullivan, B; Lau, M; Parent, A; Jaffray, D A

    2007-01-01

    Most IMRT techniques have been designed to treat targets smaller than the field size of conventional linac accelerators. In order to overcome the field size restrictions in applying IMRT, we developed a two isocenter IMRT technique to treat long volume targets. The technique exploits an extended dose gradient throughout a junction region of 4-6 cm to minimize the impact of field match errors on a junction dose and manipulates the inverse planning and IMRT segments to fill in the dose gradient and achieve dose uniformity. Techniques for abutting both conventional fields with IMRT ('Static + IMRT') and IMRT fields ('IMRT + IMRT') using two separate isocenters have been developed. Five long volume sarcoma cases have been planned in Pinnacle (Philips, Madison, USA) using Elekta Synergy and Varian 2100EX linacs; two of the cases were clinically treated with this technique. Advantages were demonstrated with well-controlled junction target uniformity and tolerance to setup uncertainties. The junction target dose heterogeneity was controlled at a level of ±5%; for 3 mm setup errors at the field edges, the junction target dose changed less than 5% and the dose sparing to organs at risk (OARs) was maintained. Film measurements confirmed the treatment planning results

  19. Hyperfractionated radiotherapy alone for clinical stage I nonsmall cell lung cancer

    International Nuclear Information System (INIS)

    Jeremic, Branislav; Shibamoto, Yuta; Acimovic, Ljubisa; Milisavljevic, Slobodan

    1997-01-01

    Purpose: Among patients with Stage I nonsmall cell lung cancer (NSCLC), those treated with conventional radiotherapy show poorer prognosis than those treated by surgery. To improve the prognosis of such patients, we have used hyperfractionated radiation therapy. Methods and Materials: Between 1988 and 1993, 49 patients were treated with hyperfractionated radiotherapy with 1.2 Gy twice daily to a total dose of 69.6 Gy. All patients were technically operable, but 29 had medical problems and 20 refused surgery. The median age and Karnofsky Performance Status was 63 years and 90, respectively. No patient received chemotherapy or immunotherapy. Prophylactic mediastinal irradiation was not given. Results: The median survival time was 33 months, and the 5-year survival rate was 30%. The rate at 5 years for freedom from each of relapse, local recurrence, mediastinal lymphnode metastasis, and distant metastasis was 41%, 55%, 89%, and 75%, respectively. Univariate analysis revealed that higher Karnofsky Performance Status score, absence of weight loss before treatment, and T1 stage were associated with better survival, although the T stage became insignificant on multivariate analysis. There were two Grade 3 acute toxicities and three Grade 3 late toxicities, but there was no Grade 4-5 toxicity. Conclusion: The results of this study compare favorably with those of most previous studies employing conventional fractionation. Further studies on hyperfractionation seem to be warranted for Stage I NSCLC

  20. Single-Arc IMRT?

    International Nuclear Information System (INIS)

    Bortfeld, Thomas; Webb, Steve

    2009-01-01

    The idea of delivering intensity-modulated radiation therapy (IMRT) with a multileaf collimator in a continuous dynamic mode during a single rotation of the gantry has recently gained momentum both in research and industry. In this note we investigate the potential of this Single-Arc IMRT technique at a conceptual level. We consider the original theoretical example case from Brahme et al that got the field of IMRT started. Using analytical methods, we derive deliverable intensity 'landscapes' for Single-Arc as well as standard IMRT and Tomotherapy. We find that Tomotherapy provides the greatest flexibility in shaping intensity landscapes and that it allows one to deliver IMRT in a way that comes close to the ideal case in the transverse plane. Single-Arc and standard IMRT make compromises in different areas. Only in relatively simple cases that do not require substantial intensity modulation will Single-Arc be dosimetrically comparable to Tomotherapy. Compared with standard IMRT, Single-Arc could be dosimetrically superior in certain cases if one is willing to accept the spreading of low dose values over large volumes of normal tissue. In terms of treatment planning, Single-Arc poses a more challenging optimization problem than Tomotherapy or standard IMRT. We conclude that Single-Arc holds potential as an efficient IMRT technique especially for relatively simple cases. In very complex cases, Single-Arc may unduly compromise the quality of the dose distribution, if one tries to keep the treatment time below 2 min or so. As with all IMRT techniques, it is important to explore the tradeoff between plan quality and the efficiency of its delivery carefully for each individual case. (note)

  1. An IMRT dose distribution study using commercial verification software

    International Nuclear Information System (INIS)

    Grace, M.; Liu, G.; Fernando, W.; Rykers, K.

    2004-01-01

    Full text: The introduction of IMRT requires users to confirm that the isodose distributions and relative doses calculated by their planning system match the doses delivered by their linear accelerators. To this end the commercially available software, VeriSoft TM (PTW-Freiburg, Germany) was trialled to determine if the tools and functions it offered would be of benefit to this process. The CMS Xio (Computer Medical System) treatment planning system was used to generate IMRT plans that were delivered with an upgraded Elekta SL15 linac. Kodak EDR2 film sandwiched in RW3 solid water (PTW-Freiburg, Germany) was used to measure the IMRT fields delivered with 6 MV photons. The isodose and profiles measured with the film generally agreed to within ± 3% or ± 3 mm with the planned doses, in some regions (outside the IMRT field) the match fell to within ± 5%. The isodose distributions of the planning system and the film could be compared on screen and allows for electronic records of the comparison to be kept if so desired. The features and versatility of this software has been of benefit to our IMRT QA program. Furthermore, the VeriSoft TM software allows for quick and accurate, automated planar film analysis.Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  2. Late course accelerated fractionation in radiotherapy of esophageal carcinoma

    International Nuclear Information System (INIS)

    Shi, X.-H.; Yao, W.; Liu, T.

    1999-01-01

    Purpose: To evaluate the efficacy of adding accelerated fractionation after completing two thirds of routine fractionated radiotherapy in esophageal carcinoma.Methods and materials: From April 1988 to April 1990, 85 patients with histologically confirmed carcinoma of the esophagus were randomized into two groups. (1) The conventional fractionation (CF) group, received 1.8 Gy per day five times a week to a total dose of 68.4 Gy in 7-8 weeks, and (2) the late course accelerated hyperfractionated (LCAF) group which received the same schedule as the CF group during the first two thirds of the course of radiotherapy to a dose of 41.4 Gy/23 fx/4 to 5 weeks. This was then followed by accelerated hyperfractionation using reduced fields. In the LCAF portion of the radiotherapeutic course, the irradiation schedule was changed to 1.5 Gy twice a day, with an interval of 4 h between fractions, to a dose of 27 Gy/18 fx. Thus the total dose was also 68.4 Gy, the same as the CF group, but the course of radiotherapy was shorter, being only 6.4 weeks. The same Cobalt 60 teletherapy unit was used to treat all the cases.Results: The 5 year actuarial survival and disease-free survival rates in the LCAF group were 34% and 42%, as compared to 15% and 15% respectively in the CF group, all statistically significant. Better local control was seen in the LCAF group than in the CF group, the 5 year control rates being 55% versus 21% (P=0.003). The acute reactions were increased but acceptable in the LCAF patients, the radiation treatments could be completed without any breaks. The late reactions as observed after 5 years were not increased in comparison with the CF patients.Conclusions: The results from this study show that the late course accelerated hyperfractionated radiotherapy regime can improve results in esophageal carcinoma, with acceptable acute reactions as compared to conventional radiotherapy. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Head-and-neck IMRT treatments assessed with a Monte Carlo dose calculation engine

    International Nuclear Information System (INIS)

    Seco, J; Adams, E; Bidmead, M; Partridge, M; Verhaegen, F

    2005-01-01

    IMRT is frequently used in the head-and-neck region, which contains materials of widely differing densities (soft tissue, bone, air-cavities). Conventional methods of dose computation for these complex, inhomogeneous IMRT cases involve significant approximations. In the present work, a methodology for the development, commissioning and implementation of a Monte Carlo (MC) dose calculation engine for intensity modulated radiotherapy (MC-IMRT) is proposed which can be used by radiotherapy centres interested in developing MC-IMRT capabilities for research or clinical evaluations. The method proposes three levels for developing, commissioning and maintaining a MC-IMRT dose calculation engine: (a) development of a MC model of the linear accelerator, (b) validation of MC model for IMRT and (c) periodic quality assurance (QA) of the MC-IMRT system. The first step, level (a), in developing an MC-IMRT system is to build a model of the linac that correctly predicts standard open field measurements for percentage depth-dose and off-axis ratios. Validation of MC-IMRT, level (b), can be performed in a rando phantom and in a homogeneous water equivalent phantom. Ultimately, periodic quality assurance of the MC-IMRT system is needed to verify the MC-IMRT dose calculation system, level (c). Once the MC-IMRT dose calculation system is commissioned it can be applied to more complex clinical IMRT treatments. The MC-IMRT system implemented at the Royal Marsden Hospital was used for IMRT calculations for a patient undergoing treatment for primary disease with nodal involvement in the head-and-neck region (primary treated to 65 Gy and nodes to 54 Gy), while sparing the spinal cord, brain stem and parotid glands. Preliminary MC results predict a decrease of approximately 1-2 Gy in the median dose of both the primary tumour and nodal volumes (compared with both pencil beam and collapsed cone). This is possibly due to the large air-cavity (the larynx of the patient) situated in the centre

  4. IMRT in a pregnant patient: how to reduce the fetal dose?

    DEFF Research Database (Denmark)

    Josipovic, Mirjana; Nyström, Håkan; Kjaer-Kristoffersen, Flemming

    2008-01-01

    dose distribution. The peripheral dose originating from the final IMRT plan was measured at distances reaching from the most proximal to the most distal fetal position, along the accelerator's longitudinal axis, using an anthropomorphic phantom extended with water-equivalent plastic. The measured...... was built and placed beneath the accelerator head, extending caudally from the field edge, to function as an extra collimator jaw. This shield reduced the fetal dose by a factor of 3.5. The peripheral dose components were also measured for simple rectangular fields and also here the collimator scatter...... was the greatest contributor to the peripheral dose. Therefore, the shielding used for the IMRT treatment of our patient could also be used when shielding in conventional radiotherapy. It is important for a radiation therapy department to be prepared for treatment of a pregnant patient to shield the fetus...

  5. Rapidly alternating combination of cisplatin-based chemotherapy and hyperfractionated accelerated radiotherapy in split course for Stage IIIA and Stage IIIB non-small cell lung cancer: results of a Phase I-II study by the GOTHA group

    Energy Technology Data Exchange (ETDEWEB)

    Alberto, P.; Mermillod, B. [Hopital Cantonal Geneve, Geneva (Switzerland); Mirimanoff, R.O.; Leyvraz, S.; Nagy-Mignotte, H.; Bolla, M.; Wellmann, D.; Moro, D.; Brambilla, E. [Hopital Cantonal Universitaire, Lausanne (Switzerland)

    1995-08-01

    The prognosis of stage III non-small cell lung cancer (NSCLC) can be improved by a combination of radiotherapy (RT) and chemotherapy (CT). In this study, the GOTHA group evaluated the feasibility, tolerance, tumour response, pattern of failure and effect on survival of a combination alternating accelerated hyperfractionated (AH) RT and CT in patients with tumour stage III NSCLC. Toxic effects were leucopenia, nausea and vomiting, mucositis, diarrhoea, alopecia and peripheral neuropathy. Alternating CT and AHRT, as used in this study, were well tolerated and allowed full dose delivery within less than 12 weeks. Initial response was not predictive of survival. The survival curve is encouraging and the 5 year survival is superior to the 5% generally observed with conventionally fractionated radiotherapy. (author).

  6. Prospective randomized comparison of single-dose versus hyperfractionated total-body irradiation in patients with hematologic malignancies

    International Nuclear Information System (INIS)

    Girinsky, T.; Benhamou, E.; Bourhis, J.H.; Dhermain, F.; Guillot-Valls, D.; Ganansia, V.; Luboinski, M.; Perez, A.; Cosset, J.M.; Socie, G.; Baume, D.; Bouaouina, N.; Briot, E.; Baudre, A.; Bridier, A.; Pico, J.L.

    2001-01-01

    The efficiency of the two irradiation modes are similar, but the hyperfractionated irradiation seems superior in term of global and specific survival. The incidence rates of pneumopathies are not different between the two groups but the incidence rate of the liver vein-occlusive illness is superior in the group treated by non fractionated whole body irradiation. The cost of the hyperfractionated whole body irradiation is superior to this one of the non fractionated whole body irradiation around a thousand dollars. (N.C.)

  7. Effects of continuous hyperfractionated accelerated and conventionally fractionated radiotherapy on the parotid and submandibular salivary glands of rhesus monkeys

    International Nuclear Information System (INIS)

    Price, R.E.; Ang, K.K.; Stephens, L.C.; Peters, L.J.

    1995-01-01

    Radiotherapy is a major treatment modality for head and neck cancer. It is often not possible to exclude the salivary glands from the treatment fields. The unique susceptibility of the serous cells of the salivary glands to irradiation often results in xerostomia with ensuing secondary complications and discomfort to the patients. Recent reports have suggested that continuous hyperfractionated accelerated radiotherapy (CHART) can lead to considerably less reduction in salivary flow of the parotid salivary gland than conventional radiotherapy. This study was undertaken to assess histologic changes of salivary glands induced by CHART and conventional radiation fractionation schedules. The parotid and submandibular salivary glands of adult rhesus monkeys were irradiated with cobalt-60 γ radiation at 50 Gy/20 fractions/4 weeks, 55 Gy/25 fractions/5 weeks, or 54 Gy/36 fractions/12 days (CHART). Salivary tissues were harvested at 16 weeks following irradiation and evaluated histopathologically. Microscopically, the glands receiving 50 Gy, 55 Gy, or CHART were virtually indistinguishable. There was severe atrophy and fibrosis of all glands. Quantitative analysis revealed that 50 Gy, 55 Gy, and CHART induced a reduction of serous acini in parotid glands by 86.4%, 84.8%, and 88.8%, respectively. In submandibular glands, serous acini were reduced by 99.4%, 99.0%, and 100%, respectively. The corresponding reduction in mucous acini were 98.4%, 98.4%, and 99.2%, respectively. These histopathologic and quantitative morphologic studies show that the magnitude of serous gland atrophy in the parotid and submandibular salivary glands of rhesus monkeys was similar at 16 weeks after receiving 50 Gy in 20 fractions, 55 Gy in 25 fractions, or CHART

  8. Inverse planning IMRT

    International Nuclear Information System (INIS)

    Rosenwald, J.-C.

    2008-01-01

    The lecture addressed the following topics: Optimizing radiotherapy dose distribution; IMRT contributes to optimization of energy deposition; Inverse vs direct planning; Main steps of IMRT; Background of inverse planning; General principle of inverse planning; The 3 main components of IMRT inverse planning; The simplest cost function (deviation from prescribed dose); The driving variable : the beamlet intensity; Minimizing a 'cost function' (or 'objective function') - the walker (or skier) analogy; Application to IMRT optimization (the gradient method); The gradient method - discussion; The simulated annealing method; The optimization criteria - discussion; Hard and soft constraints; Dose volume constraints; Typical user interface for definition of optimization criteria; Biological constraints (Equivalent Uniform Dose); The result of the optimization process; Semi-automatic solutions for IMRT; Generalisation of the optimization problem; Driving and driven variables used in RT optimization; Towards multi-criteria optimization; and Conclusions for the optimization phase. (P.A.)

  9. SU-E-T-21: A Novel Sampling Algorithm to Reduce Intensity-Modulated Radiation Therapy (IMRT) Optimization Time

    International Nuclear Information System (INIS)

    Tiwari, P; Xie, Y; Chen, Y; Deasy, J

    2014-01-01

    Purpose: The IMRT optimization problem requires substantial computer time to find optimal dose distributions because of the large number of variables and constraints. Voxel sampling reduces the number of constraints and accelerates the optimization process, but usually deteriorates the quality of the dose distributions to the organs. We propose a novel sampling algorithm that accelerates the IMRT optimization process without significantly deteriorating the quality of the dose distribution. Methods: We included all boundary voxels, as well as a sampled fraction of interior voxels of organs in the optimization. We selected a fraction of interior voxels using a clustering algorithm, that creates clusters of voxels that have similar influence matrix signatures. A few voxels are selected from each cluster based on the pre-set sampling rate. Results: We ran sampling and no-sampling IMRT plans for de-identified head and neck treatment plans. Testing with the different sampling rates, we found that including 10% of inner voxels produced the good dose distributions. For this optimal sampling rate, the algorithm accelerated IMRT optimization by a factor of 2–3 times with a negligible loss of accuracy that was, on average, 0.3% for common dosimetric planning criteria. Conclusion: We demonstrated that a sampling could be developed that reduces optimization time by more than a factor of 2, without significantly degrading the dose quality

  10. Image guided IMRT dosimetry using anatomy specific MOSFET configurations.

    Science.gov (United States)

    Amin, Md Nurul; Norrlinger, Bern; Heaton, Robert; Islam, Mohammad

    2008-06-23

    We have investigated the feasibility of using a set of multiple MOSFETs in conjunction with the mobile MOSFET wireless dosimetry system, to perform a comprehensive and efficient quality assurance (QA) of IMRT plans. Anatomy specific MOSFET configurations incorporating 5 MOSFETs have been developed for a specially designed IMRT dosimetry phantom. Kilovoltage cone beam computed tomography (kV CBCT) imaging was used to increase the positional precision and accuracy of the detectors and phantom, and so minimize dosimetric uncertainties in high dose gradient regions. The effectiveness of the MOSFET based dose measurements was evaluated by comparing the corresponding doses measured by an ion chamber. For 20 head and neck IMRT plans the agreement between the MOSFET and ionization chamber dose measurements was found to be within -0.26 +/- 0.88% and 0.06 +/- 1.94% (1 sigma) for measurement points in the high dose and low dose respectively. A precision of 1 mm in detector positioning was achieved by using the X-Ray Volume Imaging (XVI) kV CBCT system available with the Elekta Synergy Linear Accelerator. Using the anatomy specific MOSFET configurations, simultaneous measurements were made at five strategically located points covering high dose and low dose regions. The agreement between measurements and calculated doses by the treatment planning system for head and neck and prostate IMRT plans was found to be within 0.47 +/- 2.45%. The results indicate that a cylindrical phantom incorporating multiple MOSFET detectors arranged in an anatomy specific configuration, in conjunction with image guidance, can be utilized to perform a comprehensive and efficient quality assurance of IMRT plans.

  11. A high-speed scintillation-based electronic portal imaging device to quantitatively characterize IMRT delivery.

    Science.gov (United States)

    Ranade, Manisha K; Lynch, Bart D; Li, Jonathan G; Dempsey, James F

    2006-01-01

    We have developed an electronic portal imaging device (EPID) employing a fast scintillator and a high-speed camera. The device is designed to accurately and independently characterize the fluence delivered by a linear accelerator during intensity modulated radiation therapy (IMRT) with either step-and-shoot or dynamic multileaf collimator (MLC) delivery. Our aim is to accurately obtain the beam shape and fluence of all segments delivered during IMRT, in order to study the nature of discrepancies between the plan and the delivered doses. A commercial high-speed camera was combined with a terbium-doped gadolinium-oxy-sulfide (Gd2O2S:Tb) scintillator to form an EPID for the unaliased capture of two-dimensional fluence distributions of each beam in an IMRT delivery. The high speed EPID was synchronized to the accelerator pulse-forming network and gated to capture every possible pulse emitted from the accelerator, with an approximate frame rate of 360 frames-per-second (fps). A 62-segment beam from a head-and-neck IMRT treatment plan requiring 68 s to deliver was recorded with our high speed EPID producing approximately 6 Gbytes of imaging data. The EPID data were compared with the MLC instruction files and the MLC controller log files. The frames were binned to provide a frame rate of 72 fps with a signal-to-noise ratio that was sufficient to resolve leaf positions and segment fluence. The fractional fluence from the log files and EPID data agreed well. An ambiguity in the motion of the MLC during beam on was resolved. The log files reported leaf motions at the end of 33 of the 42 segments, while the EPID observed leaf motions in only 7 of the 42 segments. The static IMRT segment shapes observed by the high speed EPID were in good agreement with the shapes reported in the log files. The leaf motions observed during beam-on for step-and-shoot delivery were not temporally resolved by the log files.

  12. A high-speed scintillation-based electronic portal imaging device to quantitatively characterize IMRT delivery

    International Nuclear Information System (INIS)

    Ranade, Manisha K.; Lynch, Bart D.; Li, Jonathan G.; Dempsey, James F.

    2006-01-01

    We have developed an electronic portal imaging device (EPID) employing a fast scintillator and a high-speed camera. The device is designed to accurately and independently characterize the fluence delivered by a linear accelerator during intensity modulated radiation therapy (IMRT) with either step-and-shoot or dynamic multileaf collimator (MLC) delivery. Our aim is to accurately obtain the beam shape and fluence of all segments delivered during IMRT, in order to study the nature of discrepancies between the plan and the delivered doses. A commercial high-speed camera was combined with a terbium-doped gadolinium-oxy-sulfide (Gd 2 O 2 S:Tb) scintillator to form an EPID for the unaliased capture of two-dimensional fluence distributions of each beam in an IMRT delivery. The high speed EPID was synchronized to the accelerator pulse-forming network and gated to capture every possible pulse emitted from the accelerator, with an approximate frame rate of 360 frames-per-second (fps). A 62-segment beam from a head-and-neck IMRT treatment plan requiring 68 s to deliver was recorded with our high speed EPID producing approximately 6 Gbytes of imaging data. The EPID data were compared with the MLC instruction files and the MLC controller log files. The frames were binned to provide a frame rate of 72 fps with a signal-to-noise ratio that was sufficient to resolve leaf positions and segment fluence. The fractional fluence from the log files and EPID data agreed well. An ambiguity in the motion of the MLC during beam on was resolved. The log files reported leaf motions at the end of 33 of the 42 segments, while the EPID observed leaf motions in only 7 of the 42 segments. The static IMRT segment shapes observed by the high speed EPID were in good agreement with the shapes reported in the log files. The leaf motions observed during beam-on for step-and-shoot delivery were not temporally resolved by the log files

  13. Second Study of Hyper-Fractionated Radiotherapy

    Directory of Open Access Journals (Sweden)

    R. Jacob

    1999-01-01

    Full Text Available Purpose and Method. Hyper-fractionated radiotherapy for treatment of soft tissue sarcomas is designed to deliver a higher total dose of radiation without an increase in late normal tissue damage. In a previous study at the Royal Marsden Hospital, a total dose of 75 Gy using twice daily 1.25 Gy fractions resulted in a higher incidence of late damage than conventional radiotherapy using 2 Gy daily fractions treating to a total of 60 Gy. The current trial therefore used a lower dose per fraction of 1.2 Gy and lower total dose of 72 Gy, with 60 fractions given over a period of 6 weeks.

  14. SU-E-T-521: Feasibility Study of a Rotational Step-And-Shoot IMRT Treatment Planning Approach

    International Nuclear Information System (INIS)

    Zhu, X; Chang, S; Cullip, T; Yuan, L; Zhang, X; Lian, J; Tang, X; Tracton, G; Dooley, J

    2014-01-01

    Purpose: Rotational step-and-shot IMRT (r-IMRT) could improve delivery efficiency with good dose conformity, especially if it can leverage the burst mode of the accelerator where radiation is turned on/off momentarily while the gantry rotates continuously. The challenge for the r-IMRT planning is to minimize the number of beams to achieve a fast and smooth rotational delivery. Methods: Treatment plans for r-IMRT were created using an in-house treatment planning system. To generate the plan using a very few beams, gantry angle was optimized by weighting the beam monitoring unit (MU), and beam shape optimization was a combination of column search with k-means clustering. A prostate case and a head and neck case were planned using r-IMRT. The dosimetry is compared to s-IMRT planned with Varian Eclipse treatment planning system. Results: With the same PTV dose coverage D95=100%, the r-IMRT plans shows comparable sparing as the s-IMRT plans in the prostate for the rectum D10cc and the bladder Dmean, and in the head and neck for the spinal cord Dmax, the brain stem Dmax, the left/right parotid Dmean, the larynx Dmean, and the mandible Dmean. Both plans meet the established institutional clinical dosimetric criteria. The r-IMRT plan uses 19 beam/405 MU for the prostate, and 68 beam/880 MU for the head and neck, while the s-IMRT uses 7 beam/724 MU and 9 beam/1812 MU, respectively. Compared to the corresponding s-IMRT, r-IMRT has a reduction of MUs of 44% for the prostate case and 41% for the head and neck case. Conclusions: We have demonstrated the feasibility of a rotational step and shoot IMRT treatment planning approach that significantly shortens the conventional IMRT treatment beam-on time without degrading the dose comformity

  15. SU-E-T-521: Feasibility Study of a Rotational Step-And-Shoot IMRT Treatment Planning Approach

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, X [Univ. of North Carolina at Chapel Hill, Chapel Hill, NC (United States); Chang, S [UNC School of Medicine, Chapel Hill, NC (United States); Cullip, T [UNC Hospitals, Chapel Hill, NC (United States); Yuan, L; Zhang, X [Duke University, Durham, NC (United States); Lian, J; Tang, X [UniversityNorth Carolina, Chapel Hill, NC (United States); Tracton, G; Dooley, J [University of North Carolina, Chapel Hill, NC (United States)

    2014-06-01

    Purpose: Rotational step-and-shot IMRT (r-IMRT) could improve delivery efficiency with good dose conformity, especially if it can leverage the burst mode of the accelerator where radiation is turned on/off momentarily while the gantry rotates continuously. The challenge for the r-IMRT planning is to minimize the number of beams to achieve a fast and smooth rotational delivery. Methods: Treatment plans for r-IMRT were created using an in-house treatment planning system. To generate the plan using a very few beams, gantry angle was optimized by weighting the beam monitoring unit (MU), and beam shape optimization was a combination of column search with k-means clustering. A prostate case and a head and neck case were planned using r-IMRT. The dosimetry is compared to s-IMRT planned with Varian Eclipse treatment planning system. Results: With the same PTV dose coverage D95=100%, the r-IMRT plans shows comparable sparing as the s-IMRT plans in the prostate for the rectum D10cc and the bladder Dmean, and in the head and neck for the spinal cord Dmax, the brain stem Dmax, the left/right parotid Dmean, the larynx Dmean, and the mandible Dmean. Both plans meet the established institutional clinical dosimetric criteria. The r-IMRT plan uses 19 beam/405 MU for the prostate, and 68 beam/880 MU for the head and neck, while the s-IMRT uses 7 beam/724 MU and 9 beam/1812 MU, respectively. Compared to the corresponding s-IMRT, r-IMRT has a reduction of MUs of 44% for the prostate case and 41% for the head and neck case. Conclusions: We have demonstrated the feasibility of a rotational step and shoot IMRT treatment planning approach that significantly shortens the conventional IMRT treatment beam-on time without degrading the dose comformity.

  16. Matching tomographic IMRT fields with static photon fields

    International Nuclear Information System (INIS)

    Sethi, A.; Leybovich, L.; Dogan, N.; Emami, B.

    2001-01-01

    The matching of abutting radiation fields presents a challenging problem in radiation therapy. Due to sharp penumbra of linear accelerator beams, small (1-2 mm) errors in field positioning can lead to large (>30%) hot or cold spots in the abutment region. With head and neck immobilization devices (thermoplastic mask/aquaplast) an average setup error of 3 mm has been reported. Therefore hot or cold spots approaching 50% of the prescription dose may occur along the matchline. Although abutting radiation fields have been investigated for static fields, there is no reported study regarding matching of tomographic IMRT and static fields. Compared to static fields, the matching of tomographic IMRT fields with static fields is more complicated. Since IMRT and static fields are planned on separate treatment planning computers, the dose in the abutment region is not specified. In addition, commonly used techniques for matching fields, such as feathering of junctions, are not practical. We have developed a method that substantially reduces dose inhomogeneity in the abutment region. In this method, a 'buffer zone' around the matchline was created and was included as part of the target for both IMRT and static field plans. In both fields, a small dose gradient (≤3%/mm) in the buffer zone was created. In the IMRT plan, the buffer zone was divided into three sections with dose varying from 83% to 25% of prescription dose. The static field dose profile was modified using either a specially designed physical (hard) or a dynamic (soft) wedge. When these modified fields were matched, the combined dose in the abutment region varied by ≤10% in the presence of setup errors spanning 4 mm (±2 mm) when the hard wedge was used and 10 mm (±5 mm) with the soft wedge

  17. Phase II, two-arm RTOG trial (94-11) of bischloroethyl-nitrosourea plus accelerated hyperfractionated radiotherapy (64.0 or 70.4 Gy) based on tumor volume (> 20 or ≤ 20 cm2, respectively) in the treatment of newly-diagnosed radiosurgery-ineligible glioblastoma multiforme patients

    International Nuclear Information System (INIS)

    Coughlin, C.; Scott, C.; Langer, C.; Coia, L.; Curran, W.; Rubin, P.

    2000-01-01

    Purpose: To compare survivorship, and acute and delayed toxicities following radiation therapy (RT) of radiosurgery-ineligible glioblastoma multiforme (GBM) patients treated with tumor volume-influenced, high-dose accelerated, hyperfractionated RT plus bischloroethyl-nitrosourea (BCNU), using prior RTOG malignant glioblastoma patients as historical controls. Methods and Materials: One hundred four of 108 patients accrued from June 1994 through May 1995 from 26 institutions were analyzable. Patients were histologically confirmed with GBM, and previously untreated. Treatment assignment (52 patients/arm) was based on tumor mass (TM), defined as the product of the maximum diameter and greatest perpendicular dimension of the titanium-gadolinium-enhanced postoperative MRI: Arm A, 64 Gy, TM > 20 cm 2 ; or Arm B, 70.4 Gy, TM ≤ 20 cm 2 . Both Arms A and B received BCNU (80 mg/m 2 , under hyperhydration) days 1-3, 56-58, then 4 cycles, each 8 weeks, for a total of 6 treatment series. Results: During the 24 months immediately post-treatment, the overall median survival was 9.1 months in Arm A (64 Gy) and 11.0 months in Arm B (70.4 Gy). Median survival in recursive partitioning analysis (RPA) Class III/IV was 10.4 months in Arm A and 12.2 months in Arm B, while RPA Class V/VI was 7.6 months in Arm A and 6.1 months in Arm B. There were no grade 4 neurological toxicities in Arm A; 2 grade 4 neurological toxicities were observed in Arm B (1 motor deficit, 1 necrosis at 157 days post-treatment). Conclusion: This strategy of high-dose, accelerated hyperfractionated radiotherapy shortens overall RT treatment times while allowing dose escalation, and it provides the potential for combination with currently available, as well as newer, chemotherapy agents. Survival is comparable with previously published RTOG data, and toxicities are within acceptable limits.

  18. Hyperfractionated abdominal radiotherapy in children. Efficacy and tolerance in 13 cases

    International Nuclear Information System (INIS)

    Lagrange, J.L.; Roullet, B.; Cosset, J.M.; Sarrazin, D.; Lemerle, J.

    1984-01-01

    The experience at IGR has shown that hyperfractionation, especially abdominal has been well tolerated in adult patients. This finding led to employ this technic in the pediatric population who had failed standard treatment. An experience with hyperfractionated radiotherapy of the abdomen and liver in children, is reported. The children were treated 4 days per week, receiving 5 fractions daily of 0.7 Gy, with a 2 hours interval between each treatment. A total dose of 28 Gy was delivered in 40 fractions over 12 days. A second course of irradiation was delivered in 5 patients, 3 with abdominal treatment and 2 with liver irradiation. The vital organs were shielded with blocks at normal dose tolerance levels. The results are encouraging since an immediate efficacy was observed in 8 of 13 patients. Long term survivals were observed in 4 patients with nephroblastomas and 1 patient with a hepatoblastoma. On the other hand acute gastrointestinal tolerance seemed less good in the children than previously observed in the adults. Five radiation hepatitis appeared, immediately after the irradiation, whom four children irradiated to the entire abdomen [fr

  19. Hyperfractionated conformal radiotherapy in locally advanced prostate cancer: results of a dose escalation study

    International Nuclear Information System (INIS)

    Forman, Jeffrey D.; Duclos, Marie; Shamsa, Falah; Porter, Arthur T.; Orton, Colin

    1996-01-01

    Purpose: This study was initiated to assess the incidence of chronic complications and histologic and biochemical control following hyperfractionated conformal radiotherapy in patients with locally advanced prostate cancer. Methods and Materials: Between October 1991 and October 1994, 49 patients with locally advanced prostate cancer were entered on the first two dose levels of a prospective dose-escalation study using hyperfractionated three dimensional conformal radiotherapy. The first 25 patients received a minimum tumor dose of 78 Gy to the prostate and seminal vesicles in 6 weeks at 1.3 Gy, b.i.d. No increase in chronic toxicity compared with conventional radiotherapy was noted; therefore, an additional 24 patients were treated to a minimum tumor dose of 82.8 Gy to the prostate and seminal vesicles in 7 weeks at 1.15 Gy, b.i.d. Toxicity was scored according to the Radiation Therapy Oncology Group morbidity grading scale. Efficacy was assessed through scheduled postradiation prostate specific antigen values and ultrasound-guided biopsies. The median follow-up for the entire group was 20 months. Results: The hyperfractionated external radiation was well tolerated with minimal acute morbidity. At 30 months, the actuarial probability of Grade 2 gastrointestinal toxicity was 17%. At 30 months, the actuarial probability of Grade 2 genitourinary toxicity was 16%. There was no statistically significant difference between the two dose levels. No Grade 3 or 4 gastrointestinal or genitourinary toxicity was noted. At 12 months, 84% of patients had a prostate specific antigen ≤ 4; and 53%; ≤ 1 ng/ml. At 12 months, 71% of patients had post radiation biopsies that were either negative (55%) or showed a marked therapeutic effect (16%). Conclusion: The use of hyperfractionated conformal radiotherapy facilitated dose escalation with no increase in chronic toxicity compared to standard doses. The initial tumor response based on prostate specific antigen measurements and

  20. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    International Nuclear Information System (INIS)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A.

    2011-01-01

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa. Conclusions: There is a lack of correlation between

  1. IMRT plan verification in radiotherapy

    International Nuclear Information System (INIS)

    Vlk, P.

    2006-01-01

    This article describes the procedure for verification of IMRT (Intensity modulated radiation therapy) plan, which is used in the Oncological Institute of St. Elisabeth in Bratislava. It contains basic description of IMRT technology and developing a deployment plan for IMRT planning system CORVUS 6.0, the device Mimic (Multilammelar intensity modulated collimator) and the overall process of verifying the schedule created. The aim of verification is particularly good control of the functions of MIMIC and evaluate the overall reliability of IMRT planning. (author)

  2. The use of IMRT in Germany

    International Nuclear Information System (INIS)

    Frenzel, Thorsten; Kruell, Andreas

    2015-01-01

    Intensity modulated radiotherapy (IMRT) is frequently used, but there are no data about current frequency regarding specific tumor sites and equipment used for quality assurance (QA). An online survey about IMRT was executed from April to October 2014 by the collaborative IMRT working group (AK IMRT) of the German Association of Medical Physicists (DGMP). A total of 23 German institutions took part in the survey. Most reports came from users working with Elekta, Varian, and Siemens treatment machines, but also from TomoTherapy and BrainLab. Most frequent IMRT technology was volumetric modulated arc therapy (58.37 %: VMAT/''rapid arc''), followed by step-and-shoot IMRT (14.66 %), dynamic MLC (dMLC: 14.53 %), TomoTherapy (9.25 %), and 3.2 % other techniques. Different commercial hard- and software solutions are available for QA, whereas many institutes still develop their own phantoms. Data of 26,779 patients were included in the survey; 44 % were treated using IMRT techniques. IMRT was most frequently used for anal cancer, (whole) craniospinal irradiation, head and neck cancer, prostate cancer, other tumors in the pelvic region, gynecological tumors (except for breast cancer), and brain tumors. An estimated 10 % of all patients treated in 2014 with radiation in Germany were included in the survey. It is representative for the members of the AK IMRT. IMRT may be on the way to replace other treatment techniques. However, many scientific questions are still open. In particular, it is unclear when the IMRT technique should not be used. (orig.) [de

  3. Specific patient verification of IMRT plans using two-dimensional array of ionization chambers.)

    International Nuclear Information System (INIS)

    Rodriguez Zayas, Michael; Perez Guevara, Adrian; Reyes Gonzalez, Tommy; Gonzalez Perez, Yelina; Sola Rodriguez, Yeline; Caballero, Roberto; Lopez Lopez, Alberto; Castro Crespo, Diosdado

    2009-01-01

    The most common procedures to validate treatments with IMRT combine planning and administration which introduces the specific patient approach. IMRT is being introduced in Cuba, so it is a study to use as verification for each IMRT treatment plan with the collapsed beam method (Collapsed beams). We present three case studies to look at different situations and presentation of data. The treatment beam and collapsed obtained with an Elekta Precise linear accelerator and TPS PrecisePLAN respectively. The system used to measure a two-dimensional array of ionization chambers and VeriSoft system, both of the firm PTW. Dummy is used as solid sheets of water. The dose difference is evaluated using the gamma index applied to dose map resulting of the comparison between measured and simulated projections. Also the dose absolute is measured using a cylindrical chamber with United electrometer, which is compare with the results of the TPS. In the cases studied are shown along two perpendicular profiles. Tolerance is taken as the gamma index (5%, 5 mm). The method of collapsed beams under two- dimensional beam ionization chambers has been accepted for verification of IMRT treatments at the Radiotherapy Service of the Hospital Hermanos Ameijeiras. (Author)

  4. Intensity Modulated Radiotherapy (IMRT) in locally advanced thyroid cancer: Acute toxicity results of a phase I study

    International Nuclear Information System (INIS)

    Urbano, Teresa Guerrero; Clark, Catharine H.; Hansen, Vibeke N.; Adams, Elizabeth J.; Miles, Elizabeth A.; Mc Nair, Helen; Bidmead, A. Margaret; Warrington, Jim; Dearnaley, David P.; Harmer, Clive; Harrington, Kevin J.; Nutting, Christopher M.

    2007-01-01

    Background and purpose: This phase 1 study was designed to determine the toxicity of accelerated fractionation IMRT in locally advanced thyroid cancer. Methods: Patients with high risk locally advanced thyroid cancer who required post-operative EBRT were recruited. A single-phase inverse-planned-simultaneous-boost was delivered by IMRT: 58.8 Gy/28F (daily) to the primary tumour and involved nodes and 50 Gy/28F to the elective nodes. Acute (NCICTCv.2.0) and late toxicity (RTOG and modified LENTSOM) was collected. Results: Thirteen patients were treated (7 medullary thyroid, 2 Hurthle cell and 4 well differentiated thyroid cancer). G3 and G2 radiation dermatitis rates were 38.5% and 31%; G3 and G2 mucositis rates 8% and 53% and G3 and G2 pain 23% and 54%. Thirty-one percentage required enteral feeding. G3 and G2 xerostomia rates were 0% and 31%. Recovery was seen, with 62% patients having dysphagia G ≤ 1 2 months after IMRT. Thirty percent of patients developed L'Hermitte's syndrome. No grade 4 toxicity was observed. No dose limiting toxicity was found. Conclusions: Accelerated fractionation IMRT in this group of patients is feasible and safe. The acute toxicity appeared acceptable and early indicators of late toxicity moderate and similar to what would be expected with conventional RT. Longer follow up is required to quantify late side effects

  5. Hyperfractionated external radiation therapy in stage IIIB carcinoma of uterine cervix: a prospective pilot study

    International Nuclear Information System (INIS)

    Faria, Sergio L.; Ferrigno, Robson

    1997-01-01

    Purpose: Brazil has one of the highest incidence of carcinoma of the cervix in the world. Half of the patients have advanced stages at the diagnosis. Due to this large number of patients we decided to conduct a prospective pilot study to investigate the tolerance to and survival rate with hyperfractionated external radiotherapy only in patients with Stage IIIB carcinoma of the uterine cervix. Methods and Materials: Between January 1991 and December 1993, 23 patients underwent hyperfractionated external beam radiotherapy without brachytherapy. All cases were biopsy proven squamous cell carcinoma of cervix clinically Staged as IIIB (FIGO). Hyperfractionation (HFX) was given with 1.2 Gy doses, twice daily at 6-h interval, 5 days/week, to the whole pelvis up to 72 Gy within 30 working days. Complications were evaluated by an adaptation of the RTOG Radiation Morbidity Scoring Table graded as 1 = none/mild; 2 = moderate, and 3 = severe. Results: Follow-up ranged from 27 to 50 months (median 40 months) on the 9 to 23 living patients at the time of the analysis in December 1995. There was no severe acute toxicity, but moderate acute reaction was high: 74%. The commonest site of complication was the intestine where severe late toxicity occurred in 2 of 23 (9%). Overall survival rate at 27 months was 48% and at 40 months was 43%. Discussion: There is little information in literature about HFX in carcinoma of the cervix. This is the third published study about it and the one that gave the highest total dose with external HFX of 60 x 1.2 Gy = 72 Gy. Theoretically, through the linear quadratic formula this schedule of HFX would be equivalent to 30 x 2 Gy = 60 Gy of standard fractionation, both treatments given in 30 working days. HFX schedules must be tested to establish their safety. Present results suggest being possible to further increase the total dose in the pelvis with hyperfractionated irradiation

  6. Evaluation of the Delta4 phantom for IMRT and VMAT verification

    International Nuclear Information System (INIS)

    Bedford, James L; Lee, Young K; Wai, Philip; South, Christopher P; Warrington, Alan P

    2009-01-01

    The Delta 4 diode array phantom (Scandidos, Uppsala, Sweden) was evaluated for verification of segmental intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) on an Elekta linear accelerator (Crawley UK). The device was tested for angular sensitivity by irradiating it from 36 different gantry angles, and the responses of the device to various step-and-shoot segment doses and dose rates were evaluated using an ionization chamber as a comparison. The phantom was then compared with ionization chamber and film results for two prostate and pelvic nodes IMRT plans, two head and neck IMRT plans and two lung VMAT plans. These plans were calculated using Pinnacle 3 (Philips Radiation Oncology Systems, Madison, WI). The uniformity of angular response was better than 0.5% over the range of gantry angles. The uniformity of response of the Delta 4 to different segment monitor units and dose rates was better than 0.5%. The assessment of the IMRT and VMAT plans showed that the Delta 4 measured a dose within 2.5% of the ionization chamber, and compared to film recorded a slightly larger region (range -2% to +7%) agreeing with the planned dose to within 3% and 3 mm. The Delta 4 is a complex device and requires careful benchmarking, but following the successful completion of these measurements, the Delta 4 has been introduced into clinical use. (note)

  7. Dosimetric comparison of standard three-dimensional conformal radiotherapy followed by intensity-modulated radiotherapy boost schedule (sequential IMRT plan) with simultaneous integrated boost-IMRT (SIB IMRT) treatment plan in patients with localized carcinoma prostate.

    Science.gov (United States)

    Bansal, A; Kapoor, R; Singh, S K; Kumar, N; Oinam, A S; Sharma, S C

    2012-07-01

    DOSIMETERIC AND RADIOBIOLOGICAL COMPARISON OF TWO RADIATION SCHEDULES IN LOCALIZED CARCINOMA PROSTATE: Standard Three-Dimensional Conformal Radiotherapy (3DCRT) followed by Intensity Modulated Radiotherapy (IMRT) boost (sequential-IMRT) with Simultaneous Integrated Boost IMRT (SIB-IMRT). Thirty patients were enrolled. In all, the target consisted of PTV P + SV (Prostate and seminal vesicles) and PTV LN (lymph nodes) where PTV refers to planning target volume and the critical structures included: bladder, rectum and small bowel. All patients were treated with sequential-IMRT plan, but for dosimetric comparison, SIB-IMRT plan was also created. The prescription dose to PTV P + SV was 74 Gy in both strategies but with different dose per fraction, however, the dose to PTV LN was 50 Gy delivered in 25 fractions over 5 weeks for sequential-IMRT and 54 Gy delivered in 27 fractions over 5.5 weeks for SIB-IMRT. The treatment plans were compared in terms of dose-volume histograms. Also, Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) obtained with the two plans were compared. The volume of rectum receiving 70 Gy or more (V > 70 Gy) was reduced to 18.23% with SIB-IMRT from 22.81% with sequential-IMRT. SIB-IMRT reduced the mean doses to both bladder and rectum by 13% and 17%, respectively, as compared to sequential-IMRT. NTCP of 0.86 ± 0.75% and 0.01 ± 0.02% for the bladder, 5.87 ± 2.58% and 4.31 ± 2.61% for the rectum and 8.83 ± 7.08% and 8.25 ± 7.98% for the bowel was seen with sequential-IMRT and SIB-IMRT plans respectively. For equal PTV coverage, SIB-IMRT markedly reduced doses to critical structures, therefore should be considered as the strategy for dose escalation. SIB-IMRT achieves lesser NTCP than sequential-IMRT.

  8. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A. [Canis Lupus LLC and Department of Human Oncology, University of Wisconsin, Merrimac, Wisconsin 53561 (United States); Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States); Departments of Human Oncology, Medical Physics, and Biomedical Engineering, University of Wisconsin, Madison, Wisconsin 53792 (United States)

    2011-02-15

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa

  9. Early termination of prostate cancer hyperfractionated dose escalation study

    International Nuclear Information System (INIS)

    Forman, Jeffrey D; Porter, Arthur T; Kocheril, Paul; Grignon, David; Orton, Colin

    1996-01-01

    Purpose: This study was initiated to determine the maximum tolerable dose of hyperfractionated radiation in patients with locally advanced prostate cancer. Materials and Methods: Forty-nine patients with locally advanced prostate cancer (T3-T4 Nx, 0, 1 M0 and/or Gleason Score ≥ 8) were treated on the first two steps of a prospective dose-escalation study using hyperfractionated conformal radiotherapy. The first 25 patients received a minimum dose of 78Gy to the clinical tumor volume (CTV) including the prostate, seminal vesicle and a 5mm margin at 1.3Gy b.i.d. The second group (24 patients) received a minimum dose to the CTV of 82.8Gy at 1.15Gy b.i.d. Twenty eight patients received neo-adjuvant hormonal therapy in conjunction with their radiation (8 of 25 patients at 78Gy and 20 of 24 patients at 82.8Gy). Toxicity was scored according to the RTOG grading scale. Efficacy was evaluated by PSA levels and ultrasound guided biopsies. Median follow up was 36 and 18 months for the 78Gy and 82.8Gy dose levels, respectively. Results: No grade 3 or 4 gastrointestinal (GI) or genitourinary (GU) toxicity was noted. At 36 months, the actuarial probability of Grade 2 GI and GU toxicity were 16 and 20%, respectively. Twelve to 18 months following radiation, 41 patients (86%) underwent ultrasound guided biopsy. At 78Gy, 60% of 20 patients had a biopsy which was negative or showed a marked therapeutic effect. At 82.8Gy, these combined rates were 95% in the 21 patients who had biopsies. Nine patients (50%) who did not receive neo-adjuvant hormones had positive biopsies. No patient who received neo-adjuvant hormones plus 78Gy (5 patients) or 82.8Gy (18 patients) had a positive biopsy. Conclusion: Proceeding to the next dose level (87.4Gy) was justified by the lack of severe chronic toxicity. However, in view of the high rate of histologic sterilization when hyperfractionated irradiation was given in conjunction with neo-adjuvant hormonal therapy, it was felt to be unethical to

  10. Clinical Evaluation of Direct Aperture Optimization When Applied to Head-And-Neck IMRT

    International Nuclear Information System (INIS)

    Jones, Stephen; Williams, Matthew

    2008-01-01

    Direct Machine Parameter Optimization (DMPO) is a leaf segmentation program released as an optional item of the Pinnacle planning system (Philips Radiation Oncology Systems, Milpitas, CA); it is based on the principles of direct aperture optimization where the size, shape, and weight of individual segments are optimized to produce an intensity modulated radiation treatment (IMRT) plan. In this study, we compare DMPO to the traditional method of IMRT planning, in which intensity maps are optimized prior to conversion into deliverable multileaf collimator (MLC) apertures, and we determine if there was any dosimetric improvement, treatment efficiency gain, or planning advantage provided by the use of DMPO. Eleven head-and-neck patients treated with IMRT had treatment plans generated using each optimization method. For each patient, the same planning parameters were used for each optimization method. All calculations were performed using Pinnacle version 7.6c software and treatments were delivered using a step-and-shoot IMRT method on a Varian 2100EX linear accelerator equipped with a 120-leaf Millennium MLC (Varian Medical Systems, Palo Alto, CA). Each plan was assessed based on the calculation time, a conformity index, the composite objective value used in the optimization, the number of segments, monitor units (MUs), and treatment time. The results showed DMPO to be superior to the traditional optimization method in all areas. Considerable advantages were observed in the dosimetric quality of DMPO plans, which also required 32% less time to calculate, 42% fewer MUs, and 35% fewer segments than the conventional optimization method. These reductions translated directly into a 29% decrease in treatment times. While considerable gains were observed in planning and treatment efficiency, they were specific to our institution, and the impact of direct aperture optimization on plan quality and workflow will be dependent on the planning parameters, planning system, and

  11. Clinical experience transitioning from IMRT to VMAT for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology, Jefferson Medical College of Thomas Jefferson University, Philadelphia, PA (United States); Bar-Ad, Voichita; Siglin, Joshua [Department of Radiation Oncology, Jefferson Medical College of Thomas Jefferson University, Philadelphia, PA (United States); Cognetti, David; Curry, Joseph [Department of Otolaryngology, Jefferson Medical College of Thomas Jefferson University, Philadelphia, PA (United States); Tuluc, Madalina [Department of Pathology, Jefferson Medical College of Thomas Jefferson University, Philadelphia, PA (United States); Harrison, Amy S. [Department of Radiation Oncology, Jefferson Medical College of Thomas Jefferson University, Philadelphia, PA (United States)

    2013-07-01

    To quantify clinical differences for volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) in terms of dosimetric endpoints and planning and delivery time, twenty head and neck cancer patients have been considered for VMAT using Nucletron Oncentra MasterPlan delivered via an Elekta linear accelerator. Differences in planning time between IMRT and VMAT were estimated accounting for both optimization and calculation. The average delivery time per patient was obtained retrospectively using the record and verify software. For the dosimetric comparison, all contoured organs at risk (OARs) and planning target volumes (PTVs) were evaluated. Of the 20 cases considered, 14 had VMAT plans approved. Six VMAT plans were rejected due to unacceptable dose to OARs. In terms of optimization time, there was minimal difference between the two modalities. The dose calculation time was significantly longer for VMAT, 4 minutes per 358 degree arc versus 2 minutes for an entire IMRT plan. The overall delivery time was reduced by 9.2 ± 3.9 minutes for VMAT (51.4 ± 15.6%). For the dosimetric comparison of the 14 clinically acceptable plans, there was almost no statistical difference between the VMAT and IMRT. There was also a reduction in monitor units of approximately 32% from IMRT to VMAT with both modalities demonstrating comparable quality assurance results. VMAT provides comparable coverage of target volumes while sparing OARs for the majority of head and neck cases. In cases where high dose modulation was required for OARs, a clinically acceptable plan was only achievable with IMRT. Due to the long calculation times, VMAT plans can cause delays during planning but marked improvements in delivery time reduce patient treatment times and the risk of intra-fraction motion.

  12. Comparison of single, fractionated and hyperfractionated irradiation on the development of normal tissue damage in rat lung

    International Nuclear Information System (INIS)

    Giri, P.G.S.; Kimler, B.F.; Giri, U.P.; Cox, G.G.; Reddy, E.K.

    1985-01-01

    The effect of fractionated thoracic irradiation on the development of normal tissue damage in rats was compared to that produced by single doses. Animals received a single dose of 15 Gy, 30 Gy in 10 daily fractions of 3 Gy each (fractionation), or 30 Gy in 30 fractions of 1 Gy each 3 times a day (hyperfractionation). The treatments produced minimal lethality since a total of only 6 animals died between days 273 and 475 after the initiation of treatment, with no difference in survival observed between the control and any of the 3 treated groups. Despite the lack of lethality, evidence of lung damage was obtained by histological examination. Animals that had received either single doses or fractionated doses had more of the pulmonary parenchyma involved than did animals that had received hyperfractionated doses. The authors conclude that, in the rat lung model, a total radiation dose of 30 Gy fractionated over 14 days produces no more lethality nor damage to lung tissue than does 15 Gy delivered as a single dose. However, long-term effects as evidenced by deposits of collagen and development of fibrosis are significantly reduced by hyperfractionation when compared to single doses and daily fractionation

  13. Does IMRT increase the peripheral radiation dose? A comparison of treatment plans 2000 and 2010

    International Nuclear Information System (INIS)

    Salz, Henning; Eichner, Regina; Wiezorek, Tilo

    2012-01-01

    It has been reported in several papers and textbooks that IMRT treatments increase the peripheral dose in comparison with non-IMRT fields. But in clinical practice not only open fields have been used in the pre-IMRT era, but also fields with physical wedges or composed fields. The aim of this work is to test the hypothesis of increased peripheral dose when IMRT is used compared to standard conformal radiotherapy. Furthermore, the importance of the measured dose differences in clinical practice is discussed and compared with other new technologies for the cases where an increase of the peripheral dose was observed. For cancers of the head and neck, the cervix, the rectum and for the brain irradiation due to acute leukaemia, one to four plans have been calculated with IMRT or conformal standard technique (non-IMRT). In an anthropomorphic phantom the dose at a distance of 30 cm in cranio-caudal direction from the target edge was measured with TLDs using a linear accelerator Oncor registered (Siemens) for both techniques. IMRT was performed using step-and-shoot technique (7 to 11 beams), non-IMRT plans with different techniques. The results depended on the site of irradiation. For head and neck cancers IMRT resulted in an increase of 0.05 - 0.09% of the prescribed total dose (Dptv) or 40 - 70 mGy (Dptv = 65 Gy), compared to non-IMRT technique without wedges or a decrease of 0.16% (approx. 100 mGy) of the prescribed total dose compared to non-IMRT techniques with wedges. For the cervical cancer IMRT resulted in an increased dose in the periphery (+ 0.07% - 0.15% of Dptv or 30 - 70 mGy at Dptv = 45 Gy), for the rectal cancer in a dose reduction (0.21 - 0.26% of Dptv or 100 - 130 mGy at Dptv = 50 Gy) and for the brain irradiation in an increase dose (+ 0.05% of Dptv = 18 Gy or 9 mSv). In summary IMRT does not uniformly cause increased radiation dose in the periphery in the model used. It can be stated that these dose values are smaller than reported in earlier papers

  14. TH-EF-204-04: Experience of IMRT and Other Conformal Techniques in Russia

    International Nuclear Information System (INIS)

    Krylova, T.

    2016-01-01

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  15. TH-EF-204-04: Experience of IMRT and Other Conformal Techniques in Russia

    Energy Technology Data Exchange (ETDEWEB)

    Krylova, T. [Russian Research Cancer Center (Russian Federation)

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  16. Hybrid IMRT plans-concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time

    International Nuclear Information System (INIS)

    Mayo, Charles S.; Urie, Marcia M.; Fitzgerald, Thomas J.

    2005-01-01

    Purpose: To evaluate a hybrid intensity modulated radiation therapy (IMRT) technique as a class solution for treatment of the intact breast. Methods and materials: The following five plan techniques were compared for 10 breast patients using dose-volume histogram analysis: conventional wedged-field tangents (Tangents), forward-planned field-within-a-field tangents (FIF), IMRT-only tangents (IMRT tangents), conventional open plus IMRT tangents (4-field hybrid), and conventional open plus IMRT tangents with 2 anterior oblique IMRT beams (6-field hybrid). Results: The 4-field hybrid and FIF achieved dose distributions better than Tangents and IMRT tangents. The volume of tissue outside the planning target volume receiving ≥110% of prescribed dose was largest for IMRT tangents (average 158 cc) and least for 6-field hybrid (average 1 cc); the FIF and 4-field hybrid were comparable (average 15 cc). Heart volume ≥30 Gy averaged 13 cc for all techniques, except Tangents, for which it was 32 cc. Average total lung volume ≥20 Gy was 7% for all. Contralateral breast doses were < 3% for all. Planning time for hybrid techniques was significantly less than for conventional FIF technique. Conclusions: The 4-field hybrid technique is a viable class solution. The 6-field hybrid technique creates the most conformal dose distribution at the expense of more normal tissue receiving low dose

  17. Pilot study of human recombinant interferon gamma and accelerated hyperfractionated thoracic radiation therapy in patients with unresectable stage IIIA/B nonsmall cell lung cancer

    International Nuclear Information System (INIS)

    Shaw, Edward G.; Deming, Richard L.; Creagan, Edward T.; Nair, Suresh; Su, John Q.; Levitt, Ralph; Steen, Preston D.; Wiesenfeld, Martin; Mailliard, James A.

    1995-01-01

    Purpose: Gamma interferon has a wide range of properties, including the ability to sensitize solid tumor cells to the effects of ionizing radiation. The North Central Cancer Treatment Group has previously completed pilot studies of accelerated hyperfractionated thoracic radiation therapy (AHTRT) in patients with unresectable Stage IIIA/B nonsmall cell lung cancer (NSCLC). This Phase I study was designed to assess the toxicity of concomitant gamma interferon and AHTRT in a similar patient population. Methods and Materials: Between December 1991 and May 1992, 18 patients with unresectable Stage IIIA/B NSCLC were treated with daily gamma interferon (0.2 mg subcutaneously) concomitant with AHTRT (60 Gy given in 1.5 Gy twice daily fractions). All patients had an Eastern Cooperative Oncology Group performance status of 0 or 1 with weight loss < 5%. Eight patients had Stage IIIA and 10 had Stage IIIB disease. Results: Nine patients (50%) experienced severe, life-threatening, or fatal toxicities. Eight of the patients (44%) developed significant radiation pneumonitis, which was severe in six patients and fatal in two patients (11% treatment-related mortality). Two patients (11%) developed severe radiation esophagitis. With follow-up of 15-21 months, 2 patients are alive, and 16 have died. The median survival time and 1-year survival rate is 7.8 months and 38%, respectively. Conclusion: Gamma interferon appeared to sensitize normal lung tissue to the effects of radiation, as demonstrated by the high incidence of severe or fatal radiation pneumonitis. We do not recommend pursuing gamma interferon as a radiosensitizer in this setting

  18. Long-term Outcomes in Treatment of Invasive Bladder Cancer With Concomitant Boost and Accelerated Hyperfractionated Radiation Therapy

    International Nuclear Information System (INIS)

    Canyilmaz, Emine; Yavuz, Melek Nur; Serdar, Lasif; Uslu, Gonca Hanedan; Zengin, Ahmet Yasar; Aynaci, Ozlem; Haciislamoglu, Emel; Bahat, Zumrut; Yoney, Adnan

    2014-01-01

    Purpose: The aim of this study was to evaluate the long-term clinical efficacy and toxicity of concomitant boost and accelerated hyperfractionated radiation therapy (CBAHRT) in patients with invasive bladder cancer. Methods and Materials: Between October 1997 and September 2012, 334 patients with diagnoses of invasive bladder cancer were selected. These patients received CBAHRT as a bladder-conserving approach. The treatment consisted of a dose of 45 Gy/1.8 Gy to the whole pelvis with a daily concomitant boost of 1.5 Gy to the tumor. Total dose was 67.5 Gy in 5 weeks. A total of 32 patients (10.3%) had a diagnosis of stage T1, 202 (64.3%) were at stage T2, 46 (14.6%) were at stage T3a, 22 (7%) were at stage T3b, and 12 (3.8%) were at stage T4a. Results: The follow-up period was 33.1 months (range, 4.3-223.3 months). Grade 3 late intestinal toxicity was observed in 9 patients (2.9%), whereas grade 3 late urinary toxicity was observed in 8 patients (2.5%). The median overall survival (OS) was 26.3 months (95% confidence interval [CI]: 21.4-31.2). The 5-, 10, and 15-year OS rates were 32.1% (standard error [SE], ± 0.027), 17.9% (SE, ± 0.025) and 12.5% (SE, ± 0.028), respectively. The median cause-specific survival (CSS) was 42.1 months (95% CI: 28.7-55.5). The 5-, 10-, and 15-year CSS rates were 43.2% (SE, ± 0.03), 30.3% (SE, ± 0.03), and 28% (SE, ± 0.04), respectively. The median relapse-free survival (RFS) was 111.8 months (95% CI: 99.6-124). The 5-, 10-, and 15-year RFS rates were 61.9% (SE, ± 0.03), 57.6% (SE, ± 0.04), and 48.2% (SE, ± 0.07), respectively. Conclusions: The CBAHRT technique demonstrated acceptable toxicity and local control rates in patients with invasive bladder cancer, and this therapy facilitated bladder conservation. In selected patients, the CBAHRT technique is a practical alternative treatment option with acceptable 5-, 10-, and 15-year results in patients undergoing cystectomy as well as concurrent chemoradiation therapy

  19. Long-term Outcomes in Treatment of Invasive Bladder Cancer With Concomitant Boost and Accelerated Hyperfractionated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Canyilmaz, Emine, E-mail: dremocan@yahoo.com [Department of Radiation Oncology, Karadeniz Technical University, Trabzon (Turkey); Yavuz, Melek Nur [Department of Radiation Oncology, Akdeniz University, Antalya (Turkey); Serdar, Lasif [Department of Radiation Oncology, Karadeniz Technical University, Trabzon (Turkey); Uslu, Gonca Hanedan; Zengin, Ahmet Yasar [Department of Radiation Oncology, Kanuni Research and Education Hospital, Trabzon (Turkey); Aynaci, Ozlem; Haciislamoglu, Emel; Bahat, Zumrut; Yoney, Adnan [Department of Radiation Oncology, Karadeniz Technical University, Trabzon (Turkey)

    2014-11-01

    Purpose: The aim of this study was to evaluate the long-term clinical efficacy and toxicity of concomitant boost and accelerated hyperfractionated radiation therapy (CBAHRT) in patients with invasive bladder cancer. Methods and Materials: Between October 1997 and September 2012, 334 patients with diagnoses of invasive bladder cancer were selected. These patients received CBAHRT as a bladder-conserving approach. The treatment consisted of a dose of 45 Gy/1.8 Gy to the whole pelvis with a daily concomitant boost of 1.5 Gy to the tumor. Total dose was 67.5 Gy in 5 weeks. A total of 32 patients (10.3%) had a diagnosis of stage T1, 202 (64.3%) were at stage T2, 46 (14.6%) were at stage T3a, 22 (7%) were at stage T3b, and 12 (3.8%) were at stage T4a. Results: The follow-up period was 33.1 months (range, 4.3-223.3 months). Grade 3 late intestinal toxicity was observed in 9 patients (2.9%), whereas grade 3 late urinary toxicity was observed in 8 patients (2.5%). The median overall survival (OS) was 26.3 months (95% confidence interval [CI]: 21.4-31.2). The 5-, 10, and 15-year OS rates were 32.1% (standard error [SE], ± 0.027), 17.9% (SE, ± 0.025) and 12.5% (SE, ± 0.028), respectively. The median cause-specific survival (CSS) was 42.1 months (95% CI: 28.7-55.5). The 5-, 10-, and 15-year CSS rates were 43.2% (SE, ± 0.03), 30.3% (SE, ± 0.03), and 28% (SE, ± 0.04), respectively. The median relapse-free survival (RFS) was 111.8 months (95% CI: 99.6-124). The 5-, 10-, and 15-year RFS rates were 61.9% (SE, ± 0.03), 57.6% (SE, ± 0.04), and 48.2% (SE, ± 0.07), respectively. Conclusions: The CBAHRT technique demonstrated acceptable toxicity and local control rates in patients with invasive bladder cancer, and this therapy facilitated bladder conservation. In selected patients, the CBAHRT technique is a practical alternative treatment option with acceptable 5-, 10-, and 15-year results in patients undergoing cystectomy as well as concurrent chemoradiation therapy.

  20. Local control of T3 carcinomas after accelerated fractionation: a look at the 'gap'

    International Nuclear Information System (INIS)

    Wang, C.C.; Efird, Jimmy; Nakfoor, Bruce; Martins, Patricia

    1996-01-01

    Purpose: To study the effects of midcourse treatment break or gaps related to the local control of T3 carcinoma of the oropharynx and larynx following accelerated hyperfractionated radiation therapy. Methods and Materials: All patients were treated at the Massachusetts General Hospital from 1979 through 1994 with treatment consisting of 1.6 Gy per fraction, two fractions a day for the treatment of T3 carcinoma of the oropharynx and larynx. They were entered in the head and neck data base. Their treatment dates, treatment breaks, and doses vs. local control were analyzed and compared. A p-value of 0.05 was considered statistically significant. Results: A total of 162 patients were available for review. Due to the acute severe mucosal effects, most of the patients required a midcourse pause or 'break' after a dose of 38.4-48 Gy before treatment could be resumed and completed. The data indicate that (a) prolongation of the treatment gap for more than 14 days, (b) total treatment course longer than 45 days, (c) total dose less than 67 Gy, and (d) male gender adversely affected local control. In spite of the gaps, the female patients with advanced carcinomas enjoyed the benefits of improved local control after the accelerated hyperfractionated radiation therapy. Conclusions: Accelerated hyperfractionation radiation therapy using 1.6 Gy per fraction/twice-a-day (b.i.d.) for a total dose of 70.4 Gy in 6 weeks is effective in achieving high local control of T3 squamous cell carcinoma of the oropharynx and larynx. The midcourse treatment gap should be as short as possible with the projected total dose and time. Should the gaps be unduly prolonged due to various circumstances, further increase in the total dose, for example, 72-75 Gy, and/or increase of the fraction sizes, for example, 1.8-2.0 Gy/f b.i.d. after the gap may be necessary to compensate for the adverse effects of the tumor regeneration from the prolonged gap

  1. Discussion of feasibility to carry out intensity modulated radiation therapy in conventional medical electron linear accelerator treatment rooms

    International Nuclear Information System (INIS)

    Yang Haiyou; Liu Liping; Liang Yueqin; Zhang Liang; Yu Shui

    2010-01-01

    Objective: To investigate the feasibility about the shielding effect of conventional medical electron linear accelerator treatment in the existing rooms to carry out intensity modulated radiation therapy (IMRT). Methods: The estimation model given in NCRP REPORT No. 151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities i s adopted by linking instances, which presents the calculation methods on radiation level at the ambience of megavoltage medical electron linear accelerator treatment room. Results: The radiation level, as well as the additional annual effect dose of occupational and public at the ambience of accelerator treatment room, in crease to a certain extent, when conventional medical electron linear accelerator treatment room; are used to carry out IMRT. Conclusion: It is necessary to make environmental impact assessment for conventional medical electron linear accelerator treatment rooms, which will be used to execute IMRT. (authors)

  2. Concurrent chemotherapy, accelerated hyperfractionated split course radiation therapy and surgery for esophageal cancer

    International Nuclear Information System (INIS)

    Becker, M.; Adelstein, D.J.; Rice, T.W.; Kirk, M.A. van; Kirby, T.J.; Koka, A.; Tefft, M.; Zuccaro, G.

    1996-01-01

    Purpose/Objectives: A prospective single arm trial was undertaken to determine the toxicity, the clinical and pathologic response rates and survival for patients with esophageal cancer treated with concurrent chemotherapy(CC) and accelerated hyperfractionated split course radiotherapy(AHFSCRT) followed by surgical resection. Materials and Methods: A prospective single arm trial was conducted between 1991 and 1995 for patients with T1-4, N0-1, M1(celiac or supraclavicular) adenocarcinoma or squamous cell carcinoma of the esophagus. A total of 74 patients entered onto the protocol, and 72 are eligible and evaluable. Neoadjuvant chemotherapy consisting of two cycles of Cisplatin(20mg/m2/day) and 5-fluorouracil (1000mg/m2/day) given concurrently with AHSCRT 1.5Gy BID (at least 6 hour between fractions) to 2400cGy and 2100cGy, with cycles 1 and 2 of chemotherapy respectively. Patients were staged/restaged with barium esophagram(BS), computerized tomograph of the chest(CAT), upper endoscopy(EGD) with ultrasound (EUS) and evaluated for surgical resection. A single adjuvant course of concurrent chemotherapy and AHSCRT was delivered for those patients who were pathologic partial responders(pPR). Results: Initial clinical staging revealed one patient stage I, 24 patients' stage IIA, 2 patients' with stage IIB, 34 patients' with stage III and 6 patients' with stage IV disease. Five patients could not be staged adequately. The toxicity to neoadjuvant therapy included nausea in 85% (grade 3 in 1%), esophagitis 90% (grade 3 in 18%), neutropenia grade 3 of 43% (with fever 17%), thrombocytopenia grade 4 in 10% and nephrotoxicity in 8%. There was one death due to neoadjuvant therapy. Of the 72 evaluable patients, 67 underwent surgery, and 65(90%) had a complete resection. Twenty-seven percent were pathologic complete responders, including 22% with adenocarcinoma and 36% with squamous cell carcinoma. Complete pathologic response after neoadjuvant therapy was accurately predicted by

  3. Letter to the Editor on 'Single-Arc IMRT?'.

    Science.gov (United States)

    Otto, Karl

    2009-04-21

    In the note 'Single Arc IMRT?' (Bortfeld and Webb 2009 Phys. Med. Biol. 54 N9-20), Bortfeld and Webb present a theoretical investigation of static gantry IMRT (S-IMRT), single-arc IMRT and tomotherapy. Based on their assumptions they conclude that single-arc IMRT is inherently limited in treating complex cases without compromising delivery efficiency. Here we present an expansion of their work based on the capabilities of the Varian RapidArc single-arc IMRT system. Using the same theoretical framework we derive clinically deliverable single-arc IMRT plans based on these specific capabilities. In particular, we consider the range of leaf motion, the ability to rapidly and continuously vary the dose rate and the choice of collimator angle used for delivery. In contrast to the results of Bortfeld and Webb, our results show that single-arc IMRT plans can be generated that closely match the theoretical optimum. The disparity in the results of each investigation emphasizes that the capabilities of the delivery system, along with the ability of the optimization algorithm to exploit those capabilities, are of particular importance in single-arc IMRT. We conclude that, given the capabilities available with the RapidArc system, single-arc IMRT can produce complex treatment plans that are delivered efficiently (in approximately 2 min).

  4. Costs of conventional radical radiotherapy versus continuous hyperfractionated accelerated radiotherapy (CHART) in the treatment of patients with head and neck cancer or carcinoma of the bronchus. Medical Research Council CHART Steering Committee.

    Science.gov (United States)

    Coyle, D; Drummond, M F

    1997-01-01

    The objective of this study was to compare the costs of treatment with continuous hyperfractionated accelerated radiotherapy (CHART) and those of conventional radiotherapy for patients with (1) head and neck cancer and (2) carcinoma of the bronchus. The study was conducted concurrently with two multicentre randomized controlled trials. Data were collected on the use of hospital and community service resources and patients' travel for treatment. Data on resource use up to 3 months after entry to the study were available for 526 head and neck patients (314 receiving CHART and 212 conventional therapy) and 284 bronchus patients (175 CHART and 109 conventional therapy). For patients with head and neck cancer, CHART cost Pounds 1092 (P hostel facilities. The results of this cost analysis will help to facilitate a decision about whether the benefits of CHART, as determined by the clinical trials, are worth the additional costs of hospital-based resource use. The collection of detailed patient-specific resource-use data from a number of centres allows the determination of ways for reducing the cost differential between therapies and making CHART a more cost effective treatment alternative.

  5. Hyperfractionation radiation therapy in advanced head and neck cancer

    International Nuclear Information System (INIS)

    Kim, Jin Hee; Ye, Ji Won

    2003-01-01

    The effects of hyperfractionation radiation therapy, such as the failure pattern and survival, on the treatment results in advanced stage head and neck cancer were studied. Between September 1990 and October 1998, 24 patients with advanced stage (III, IV) head and neck cancers, were treated using hyperfractionation radiation therapy in the Department at Radiation Oncology at the Keimyung University Dongsan Medical Center. The male to female ratio was 7 ; 1, and the age range from 38 to 71 years with the median of 56 years. With regard to the TNM stage, 11 patients were stage III and 13 were stage IV. The sites of primary cancer were the nasopharynx in six, the hypopharynx in 6, the larynx in five, the oropharynx in three, the maxillary sinus in three, and the oral cavity in one patient. The radiotherapy was delivered by 6 MV X-ray, with a fraction size of 1.2 Gy at two fractions a day, with at least 6 hours inter-fractional interval. The mean total radiation doses was 72 Gy, (ranging from 64.4 to 76.8 Gy). Fallow-up periods ranged between 3 and 136 months, with the median of 52 months. The overall survival rates at 3 and 5 years in all patients were 66.7% and 52.4%. The disease-free survival rates at 3 and 5 years (3YDFS, 5YDFS) in all patients Were 66.7% and 47.6%. The 3YDFS and 5YDFS in stage III patients were 81.8% and 63.6%, and those in stage IV patients were 53.8% and 32.3%. Ten patients were alive with no local nor distant failures at the time of analyses. Six patients (25%) died due to distant metastasis and 12.5% died due to local failure. Distant metastasis was the major cause of failure, but 2 patients died due to unknown failures and 3 of other diseases. The distant metastasis sites were the lung (3 patients), the bone (1 patient), and the liver (2 patients). One patient died of second esophageal cancer. There were no severe late complications, with the exception of 1 osteoradionecrosis of the mandible 58 months after treatment. Although this study was

  6. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  7. Independent checks of linear accelerators equipped with multileaf collimators

    International Nuclear Information System (INIS)

    Pavlikova, I.; Ekendahl, D.; Horakova, I.

    2005-01-01

    National Radiation Protection Institute (NRPI) provides independent checks of therapeutic equipment as a part of state supervision. In the end of 2003, the audit was broaden for linear accelerators equipped with multileaf collimators (MLC). NRPI provides TLD postal audits and on-site independent checks. This contribution describes tests for multileaf collimators and intensity modulated radiation therapy (IMRT) technique that are accomplished within the independent on-site check of linear accelerators. The character and type of tests that are necessary to pursue for multileaf collimator depends on application technique. There are three basic application of the MLC. The first we call 'static MLC' and it serves for replacing conventional blocking or for adjusting the field shape to match the beam's-eye view projection of a planning target volume during an arc rotation of the x-ray beam. This procedure is called conformal radiotherapy. The most advanced technique with MLC is intensity modulated radiation therapy. The dose can be delivered to the patient with IMRT in various different ways: dynamic MLC, segmented MLC and IMRT arc therapy. Independent audits represent an important instrument of quality assurance. Methodology for independent check of static MLC was successfully verified on two types of accelerators: Varian and Elekta. Results from pilot measurements with dynamic MLC imply that the methodology is applicable for Varian accelerators. In the future, the experience with other types of linear accelerators will contribute to renovation, modification, and broaden independent checks methodology. (authors)

  8. SU-F-T-384: Step and Shoot IMRT, VMAT and Autoplan VMAT Nasopharnyx Plan Robustness to Linear Accelerator Delivery Errors

    International Nuclear Information System (INIS)

    Pogson, EM; Hansen, C; Blake, S; Thwaites, D; Arumugam, S; Holloway, L

    2016-01-01

    Purpose: To identify the robustness of different treatment techniques in respect to simulated linac errors on the dose distribution to the target volume and organs at risk for step and shoot IMRT (ssIMRT), VMAT and Autoplan generated VMAT nasopharynx plans. Methods: A nasopharynx patient dataset was retrospectively replanned with three different techniques: 7 beam ssIMRT, one arc manual generated VMAT and one arc automatically generated VMAT. Treatment simulated uncertainties: gantry, collimator, MLC field size and MLC shifts, were introduced into these plans at increments of 5,2,1,−1,−2 and −5 (degrees or mm) and recalculated in Pinnacle. The mean and maximum doses were calculated for the high dose PTV, parotids, brainstem, and spinal cord and then compared to the original baseline plan. Results: Simulated gantry angle errors have <1% effect on the PTV, ssIMRT is most sensitive. The small collimator errors (±1 and ±2 degrees) impacted the mean PTV dose by <2% for all techniques, however for the ±5 degree errors mean target varied by up to 7% for the Autoplan VMAT and 10% for the max dose to the spinal cord and brain stem, seen in all techniques. The simulated MLC shifts introduced the largest errors for the Autoplan VMAT, with the larger MLC modulation presumably being the cause. The most critical error observed, was the MLC field size error, where even small errors of 1 mm, caused significant changes to both the PTV and the OAR. The ssIMRT is the least sensitive and the Autoplan the most sensitive, with target errors of up to 20% over and under dosages observed. Conclusion: For a nasopharynx patient the plan robustness observed is highest for the ssIMRT plan and lowest for the Autoplan generated VMAT plan. This could be caused by the more complex MLC modulation seen for the VMAT plans. This project is supported by a grant from NSW Cancer Council.

  9. SU-F-T-384: Step and Shoot IMRT, VMAT and Autoplan VMAT Nasopharnyx Plan Robustness to Linear Accelerator Delivery Errors

    Energy Technology Data Exchange (ETDEWEB)

    Pogson, EM [Institute of Medical Physics, The University of Sydney, Sydney, New South Wales (Australia); Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Sydney, NSW (Australia); Hansen, C [Laboratory of Radiation Physics, Odense University Hospital, Odense (Denmark); Institute of Clinical Research, University of Southern Denmark, Odense (Denmark); Blake, S; Thwaites, D [Institute of Medical Physics, The University of Sydney, Sydney, New South Wales (Australia); Arumugam, S [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Holloway, L [Institute of Medical Physics, The University of Sydney, Sydney, New South Wales (Australia); Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Laboratory of Radiation Physics, Odense University Hospital, Odense (Denmark); South Western Sydney Clinical School, University of New South Wales, Sydney, NSW (Australia); University of Wollongong, Wollongong, NSW (Australia)

    2016-06-15

    Purpose: To identify the robustness of different treatment techniques in respect to simulated linac errors on the dose distribution to the target volume and organs at risk for step and shoot IMRT (ssIMRT), VMAT and Autoplan generated VMAT nasopharynx plans. Methods: A nasopharynx patient dataset was retrospectively replanned with three different techniques: 7 beam ssIMRT, one arc manual generated VMAT and one arc automatically generated VMAT. Treatment simulated uncertainties: gantry, collimator, MLC field size and MLC shifts, were introduced into these plans at increments of 5,2,1,−1,−2 and −5 (degrees or mm) and recalculated in Pinnacle. The mean and maximum doses were calculated for the high dose PTV, parotids, brainstem, and spinal cord and then compared to the original baseline plan. Results: Simulated gantry angle errors have <1% effect on the PTV, ssIMRT is most sensitive. The small collimator errors (±1 and ±2 degrees) impacted the mean PTV dose by <2% for all techniques, however for the ±5 degree errors mean target varied by up to 7% for the Autoplan VMAT and 10% for the max dose to the spinal cord and brain stem, seen in all techniques. The simulated MLC shifts introduced the largest errors for the Autoplan VMAT, with the larger MLC modulation presumably being the cause. The most critical error observed, was the MLC field size error, where even small errors of 1 mm, caused significant changes to both the PTV and the OAR. The ssIMRT is the least sensitive and the Autoplan the most sensitive, with target errors of up to 20% over and under dosages observed. Conclusion: For a nasopharynx patient the plan robustness observed is highest for the ssIMRT plan and lowest for the Autoplan generated VMAT plan. This could be caused by the more complex MLC modulation seen for the VMAT plans. This project is supported by a grant from NSW Cancer Council.

  10. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    International Nuclear Information System (INIS)

    Saenz, Daniel L.; Paliwal, Bhudatt R.; Bayouth, John E.

    2014-01-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 ( 60 Co) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI), conformity index (CI), and volume receiving 60 Co ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system. (author)

  11. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans.

    Science.gov (United States)

    Saenz, Daniel L; Paliwal, Bhudatt R; Bayouth, John E

    2014-04-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI), conformity index (CI), and volume receiving ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system.

  12. Restricted Field IMRT Dramatically Enhances IMRT Planning for Mesothelioma

    International Nuclear Information System (INIS)

    Allen, Aaron M.; Schofield, Deborah; Hacker, Fred; Court, Laurence E.; Czerminska, Maria M.S.

    2007-01-01

    Purpose: To improve the target coverage and normal tissue sparing of intensity-modulated radiotherapy (IMRT) for mesothelioma after extrapleural pneumonectomy. Methods and Materials: Thirteen plans from patients previously treated with IMRT for mesothelioma were replanned using a restricted field technique. This technique was novel in two ways. It limited the entrance beams to 200 o around the target and three to four beams per case had their field apertures restricted down to the level of the heart or liver to further limit the contralateral lung dose. New constraints were added that included a mean lung dose of <9.5 Gy and volume receiving ≥5 Gy of <55%. Results: In all cases, the planning target volume coverage was excellent, with an average of 97% coverage of the planning target volume by the target dose. No change was seen in the target coverage with the new technique. The heart, kidneys, and esophagus were all kept under tolerance in all cases. The average mean lung dose, volume receiving ≥20 Gy, and volume receiving ≥5 Gy with the new technique was 6.6 Gy, 3.0%, and 50.8%, respectively, compared with 13.8 Gy, 15%, and 90% with the previous technique (p < 0.0001 for all three comparisons). The maximal value for any case in the cohort was 8.0 Gy, 7.3%, and 57.5% for the mean lung dose, volume receiving ≥20 Gy, and volume receiving ≥5 Gy, respectively. Conclusion: Restricted field IMRT provides an improved method to deliver IMRT to a complex target after extrapleural pneumonectomy. An upcoming Phase I trial will provide validation of these results

  13. Treatment accuracy of hypofractionated spine and other highly conformal IMRT treatments

    International Nuclear Information System (INIS)

    Sutherland, B.; Hanlon, P.; Charles, P.

    2011-01-01

    Full text: Spinal cord metastases pose difficult challenges for radiation treatment due to tight dose constraints and a concave PTY. This project aimed to thoroughly test the treatment accuracy of the Eclipse Treatment Planning System (TPS) for highly modulated IMRT treatments, in particular of the thoracic spine, using an Elekta Synergy Linear Accelerator. The increased understanding obtained through different quality assurance techniques allowed recommendations to be made for treatment site commissioning with improved accuracy at the Princess Alexandra Hospital (PAH). Three thoracic spine IMRT plans at the PAH were used for data collection. Complex phantom models were built using CT data, and fields simulated using Monte Carlo modelling. The simulated dose distributions were compared with the TPS using gamma analysis and DYH comparison. High resolution QA was done for all fields using the MatriXX ion chamber array, MapCHECK2 diode array shifted, and the EPlD to determine a procedure for commissioning new treatment sites. Basic spine simulations found the TPS overestimated absorbed dose to bone, however within spinal cord there was good agreement. High resolution QA found the average gamma pass rate of the fields to be 99.1 % for MatriXX, 96.5% for MapCHECK2 shifted and 97.7% for EPlD. Preliminary results indicate agreement between the TPS and delivered dose distributions higher than previously believed for the investigated IMRT plans. The poor resolution of the MatriXX, and normalisation issues with MapCHECK2 leads to probable recommendation of EPlD for future IMRT commissioning due to the high resolution and minimal setup required.

  14. Dosimetry tools and techniques for IMRT

    International Nuclear Information System (INIS)

    Low, Daniel A.; Moran, Jean M.; Dempsey, James F.; Dong Lei; Oldham, Mark

    2011-01-01

    Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA) radiation dose distributions. This report provides a comprehensive overview of how dosimeters, phantoms, and dose distribution analysis techniques should be used to support the commissioning and quality assurance requirements of an IMRT program. The proper applications of each dosimeter are described along with the limitations of each system. Point detectors, arrays, film, and electronic portal imagers are discussed with respect to their proper use, along with potential applications of 3D dosimetry. Regardless of the IMRT technique utilized, some situations require the use of multiple detectors for the acquisition of accurate commissioning data. The overall goal of this task group report is to provide a document that aids the physicist in the proper selection and use of the dosimetry tools available for IMRT QA and to provide a resource for physicists that describes dosimetry measurement techniques for purposes of IMRT commissioning and measurement-based characterization or verification of IMRT treatment plans. This report is not intended to provide a comprehensive review of commissioning and QA procedures for IMRT. Instead, this report focuses on the aspects of metrology, particularly the practical aspects of measurements that are unique to IMRT. The metrology of IMRT concerns the application of measurement instruments and their suitability, calibration, and quality control of measurements. Each of the dosimetry measurement tools has limitations that need to be considered when incorporating them into a commissioning process or a comprehensive QA program. For example, routine quality assurance procedures require the use of robust field dosimetry systems. These often exhibit limitations with respect to spatial resolution or energy response and need to themselves be commissioned against more established dosimeters. A chain of

  15. Experimental IMRT breast dosimetry in a thorax phantom

    International Nuclear Information System (INIS)

    Pimenta, Elsa B.; Campos, Tarcisio P.R.; Nogueira, Luciana B.; Lima, Andre C.S.

    2017-01-01

    Radiation therapy (RT) is an essential therapeutic method. RT is often used as adjuvant therapy in the treatment of breast cancer. The dose-volume restrictions of the organs at risk limit the prescribed dose to the target volume and biological and clinical effects may influence the final treatment outcome. The breast RT provides large risks to the adjacent organs and consequently the recommended dosimetry to the prescribed dose volume (PTV) is 50 Gy, lower than the most prescribed dose in other treatments (70-85 Gy). Such values implies in less tumor control compared to other sites. The present research proposal aimed to measure absorbed dose in a thorax phantom with synthetic breasts provided by an Intensity-Modulate Radiation Therapy (IMRT) protocol in a RT center. On the methodology, IMRT protocol was selected following recommendations from the Radiation Therapy Oncology Group (RTOG). Radiochromic films and a thorax simulator were prepared by the Ionizing Radiation Research Group (NRI). Dosimeters were calibrated on a selected linear accelerator (LINAC). The comparison of the dosimetry from treatment planning system (TPS), Xio (Elekta) and from experimental data was performed. The spatial distribution of the breast internal dose and in the adjacent organs was depicted by the experimental data. In the film's calibration, the quadratic polynomial fit presented a satisfactory coefficient. Two-dimensional dose profiles were obtained in the breast suggesting that films can supply details and information that TPS does not provide. At the phantom's dosimetry, the internal mean doses taken at the synthetic breast presented usual values above the prescribed dose, besides overall values were within the dosimetric MSKCC criterion. The non full reproduction of the build-up region in the films had occurred due to the asymmetrical positioning of the films in the inner breast, in addition to their non constant distance from the skin. The hot regions were present may be due to

  16. Evaluation of homogeneity and dose conformity in IMRT planning in prostate radiotherapy; Avaliacao da homogeneidade e conformidade de dose em planejamentos de IMRT de prostata em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Juliane S.; Leidens, Matheus; Estacio, Daniela R., E-mail: juliane.lopes@pucrs.br [Hospital Sao Lucas (PUC-RS), Porto Alegre, RS (Brazil). Servico de Radioterapia; Razera, Ricardo A.Z.; Streck, Elaine E.; Silva, Ana M.M. da [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica

    2015-12-15

    The goal of this study was to evaluate the dose distribution homogeneity and conformity of radiation therapy plans of prostate cancer using IMRT. Data from 34 treatment plans of Hospital Sao Lucas of PUCRS, where those plans were executed, were retrospectively analyzed. All of them were done with 6MV X-rays from a linear accelerator CLINAC IX, and the prescription doses varied between 60 and 74 Gy. Analyses showing the homogeneity and conformity indices for the dose distribution of those plans were made. During these analyses, some comparisons with the traditional radiation therapy planning technic, the 3D-CRT, were discussed. The results showed that there is no correlation between the prescribed dose and the homogeneity and conformity indices, indicating that IMRT works very well even for higher doses. Furthermore, a comparison between the results obtained and the recommendations of ICRU 83 was carried out. It has also been observed that the indices were really close to the ideal values. 82.4% of the cases showed a difference below 5% of the ideal value for the index of conformity, and 88.2% showed a difference below 10% for the homogeneity index. Concluding, it is possible to confirm the quality of the analyzed radiation therapy plans of prostate cancer using IMRT. (author)

  17. Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator

    International Nuclear Information System (INIS)

    Sterpin, E.; Tomsej, M.; Smedt, B. de; Reynaert, N.; Vynckier, S.

    2007-01-01

    The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm 2 ). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to the bone ribs were not fully taken into account by AAA, and small inhomogeneities may lead to planning errors. Second, AAA and MC were compared for IMRT plans in clinical conditions, i.e., dose calculations in a computed tomography scan of a patient. One ethmoid tumor, one orophaxynx and two lung tumors are presented in this paper. Small differences were found between the dose volume histograms. For instance, a 1.7% difference for the mean planning target volume dose was obtained for the ethmoid case. Since better agreement was achieved for the same plans but in homogeneous conditions, these differences must be attributed to the handling of inhomogeneities by AAA. Therefore, inherent assumptions of the algorithm, principally the assumption of independent depth and lateral directions in the scaling of the kernels, were slightly influencing AAA's validity in inhomogeneities. However, AAA showed a good accuracy overall and a great ability to handle small fields in inhomogeneous media compared to other pencil beam convolution

  18. A national dosimetric audit of IMRT

    International Nuclear Information System (INIS)

    Budgell, Geoff; Berresford, Joe; Trainer, Michael; Bradshaw, Ellie; Sharpe, Peter; Williams, Peter

    2011-01-01

    Background and purpose: A dosimetric audit of IMRT has been carried out within the UK between June 2009 and March 2010 in order to provide an independent check of safe implementation and to identify problems in the modelling and delivery of IMRT. Methods and materials: A mail based audit involving film and alanine dosimeters was utilized. Measurements were made for each individual field in an IMRT plan isocentrically in a flat water-equivalent phantom at a depth of 5 cm. The films and alanine dosimeters were processed and analysed centrally; additional ion chamber measurements were made by each participating centre. Results: 57 of 62 centres participated, with a total of 78 plans submitted. For the film measurements, all 176 fields from the less complex IMRT plans (including prostate and breast plans) achieved over 95% pixels passing a gamma criterion of 3%/3 mm within the 20% isodose. For the more complex IMRT plans (mainly head and neck) 8/245 fields (3.3%) achieved less than 95% pixels passing a 4%/4 mm gamma criterion. Of the alanine measurements, 4/78 (5.1%) of the measurements differed by >5% from the dose predicted by the treatment planning system. Three of these were large deviations of -77.1%, -29.1% and 14.1% respectively. Excluding the three measurements outside 10%, the mean difference was 0.05% with a standard deviation of 1.5%. The out of tolerance results have been subjected to further investigations. Conclusions: A dosimetric audit has been successfully carried out of IMRT implementation by over 90% of UK radiotherapy departments. The audit shows that modelling and delivery of IMRT is accurate, suggesting that the implementation of IMRT has been carried out safely.

  19. Comparison of two dimensional and three dimensional radiotherapy treatment planning in locally advanced non-small cell lung cancer treated with continuous hyperfractionated accelerated radiotherapy weekend less

    International Nuclear Information System (INIS)

    Wilson, Elena M.; Joy Williams, Frances; Ethan Lyn, Basil; Aird, Edwin G.A.

    2005-01-01

    Background and purpose: Patients with inoperable non-small cell lung cancer being treated with continuous hyperfractionated accelerated radiotherapy weekend less (CHARTWEL) were planned and treated with a three dimensional (3D) conformal protocol and comparison made with two dimensional (2D) planning, as used previously, to compare past practice and methods. Patients and methods: Twenty-four patients were planned initially using 3D and then replanned using a 2D system. The 2D plans were transferred onto the 3D system and recalculated. Dose volume histograms could then be constructed of planning target volumes for phases 1 and 2 (PTV 1 and 2, respectively), lung and spinal cord for the 2D plans and compared with the 3D plans. Results: There was a significantly lower absolute dose to the isocentre with 2D compared to 3D planning with dose reductions of 3.9% for phase 1, 4.4% for phase 2 and 4.7% for those treated with a single phase. Maximum dose to spinal cord was greater in 17 of the 24 2D plans with a median dose reduction of 0.82 Gy for 3D (P=0.04). The percentage volume of whole lung receiving ≥20 Gy (V 20 ) was greater in 16 of the 24 2D plans with a median reduction in V 20 of 2.4% for 3D (P=0.03). Conclusions: A lower dose to tumour was obtained using 2D planning due to the method of dose calculation and spinal cord and lung doses were significantly higher

  20. Intensity-modulated radiotherapy (IMRT) for carcinoma of the maxillary sinus: A comparison of IMRT planning systems

    International Nuclear Information System (INIS)

    Ahmed, Raef S.; Ove, Roger; Duan, Jun; Popple, Richard; Cobb, Glenn

    2006-01-01

    The treatment of maxillary sinus carcinoma with forward planning can be technically difficult when the neck also requires radiotherapy. This difficulty arises because of the need to spare the contralateral face while treating the bilateral neck. There is considerable potential for error in clinical setup and treatment delivery. We evaluated intensity-modulated radiotherapy (IMRT) as an improvement on forward planning, and compared several inverse planning IMRT platforms. A composite dose-volume histogram (DVH) was generated from a complex forward planned case. We compared the results with those generated by sliding window fixed field dynamic multileaf collimator (MLC) IMRT, using sets of coplanar beams. All setups included an anterior posterior (AP) beam, and 3-, 5-, 7-, and 9-field configurations were evaluated. The dose prescription and objective function priorities were invariant. We also evaluated 2 commercial tomotherapy IMRT delivery platforms. DVH results from all of the IMRT approaches compared favorably with the forward plan. Results for the various inverse planning approaches varied considerably across platforms, despite an attempt to prescribe the therapy similarly. The improvement seen with the addition of beams in the fixed beam sliding window case was modest. IMRT is an effective means of delivering radiotherapy reliably in the complex setting of maxillary sinus carcinoma with neck irradiation. Differences in objective function definition and optimization algorithms can lead to unexpected differences in the final dose distribution, and our evaluation suggests that these factors are more significant than the beam arrangement or number of beams

  1. Concomitant Cisplatin and Hyperfractionated Radiotherapy in Locally Advanced Head and Neck Cancer: 10-Year Follow-Up of a Randomized Phase III Trial (SAKK 10/94)

    International Nuclear Information System (INIS)

    Ghadjar, Pirus; Simcock, Mathew; Studer, Gabriela; Allal, Abdelkarim S.; Ozsahin, Mahmut; Bernier, Jacques; Töpfer, Michael; Zimmermann, Frank; Betz, Michael; Glanzmann, Christoph; Aebersold, Daniel M.

    2012-01-01

    Purpose: To compare the long-term outcome of treatment with concomitant cisplatin and hyperfractionated radiotherapy versus treatment with hyperfractionated radiotherapy alone in patients with locally advanced head and neck cancer. Methods and Materials: From July 1994 to July 2000, a total of 224 patients with squamous cell carcinoma of the head and neck were randomized to receive either hyperfractionated radiotherapy alone (median total dose, 74.4 Gy; 1.2 Gy twice daily; 5 days per week) or the same radiotherapy combined with two cycles of cisplatin (20 mg/m 2 for 5 consecutive days during weeks 1 and 5). The primary endpoint was the time to any treatment failure; secondary endpoints were locoregional failure, metastatic failure, overall survival, and late toxicity assessed according to Radiation Therapy Oncology Group criteria. Results: Median follow-up was 9.5 years (range, 0.1–15.4 years). Median time to any treatment failure was not significantly different between treatment arms (hazard ratio [HR], 1.2 [95% confidence interval {CI}, 0.9–1.7; p = 0.17]). Rates of locoregional failure-free survival (HR, 1.5 [95% CI, 1.1–2.1; p = 0.02]), distant metastasis-free survival (HR, 1.6 [95% CI, 1.1–2.5; p = 0.02]), and cancer-specific survival (HR, 1.6 [95% CI, 1.0–2.5; p = 0.03]) were significantly improved in the combined-treatment arm, with no difference in major late toxicity between treatment arms. However, overall survival was not significantly different (HR, 1.3 [95% CI, 0.9–1.8; p = 0.11]). Conclusions: After long-term follow-up, combined-treatment with cisplatin and hyperfractionated radiotherapy maintained improved rates of locoregional control, distant metastasis-free survival, and cancer-specific survival compared to that of hyperfractionated radiotherapy alone, with no difference in major late toxicity.

  2. Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

    International Nuclear Information System (INIS)

    Gordon, J. J.; Gardner, J. K.; Wang, S.; Siebers, J. V.

    2012-01-01

    Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of ≥5% in ∼1 mm 2 areas and ≥2% in ∼20 mm 2 areas. Conclusions: The ability to detect small dose differences (≤2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified.

  3. Evaluation of homogeneity and dose conformity in IMRT planning in prostate radiotherapy

    International Nuclear Information System (INIS)

    Lopes, Juliane S.; Leidens, Matheus; Estacio, Daniela R.; Razera, Ricardo A.Z.; Streck, Elaine E.; Silva, Ana M.M. da

    2015-01-01

    The goal of this study was to evaluate the dose distribution homogeneity and conformity of radiation therapy plans of prostate cancer using IMRT. Data from 34 treatment plans of Hospital Sao Lucas of PUCRS, where those plans were executed, were retrospectively analyzed. All of them were done with 6MV X-rays from a linear accelerator CLINAC IX, and the prescription doses varied between 60 and 74 Gy. Analyses showing the homogeneity and conformity indices for the dose distribution of those plans were made. During these analyses, some comparisons with the traditional radiation therapy planning technic, the 3D-CRT, were discussed. The results showed that there is no correlation between the prescribed dose and the homogeneity and conformity indices, indicating that IMRT works very well even for higher doses. Furthermore, a comparison between the results obtained and the recommendations of ICRU 83 was carried out. It has also been observed that the indices were really close to the ideal values. 82.4% of the cases showed a difference below 5% of the ideal value for the index of conformity, and 88.2% showed a difference below 10% for the homogeneity index. Concluding, it is possible to confirm the quality of the analyzed radiation therapy plans of prostate cancer using IMRT. (author)

  4. Can All Centers Plan Intensity-Modulated Radiotherapy (IMRT) Effectively? An External Audit of Dosimetric Comparisons Between Three-Dimensional Conformal Radiotherapy and IMRT for Adjuvant Chemoradiation for Gastric Cancer

    International Nuclear Information System (INIS)

    Chung, Hans T.; Lee, Brian; Park, Eileen; Lu, Jiade J.; Xia Ping

    2008-01-01

    Purpose: To compare dosimetric endpoints between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) at our center with limited IMRT experience, and to perform an external audit of the IMRT plans. Methods and Materials: Ten patients, who received adjuvant chemoradiation for gastric cancer, formed the study cohort. For standardization, the planning target volume (PTV) and organs at risk were recontoured with the assistance of a study protocol radiologic atlas. The cohort was replanned with CMS Xio to generate coplanar 3D-CRT and IMRT plans. All 10 datasets, including volumes but without the plans (i.e., blinded), were transmitted to an experienced center where IMRT plans were designed using Nomos Corvus (IMRT-C) and ADAC Pinnacle (IMRT-P). All IMRT plans were normalized to D95% receiving 45 Gy. Results: Intensity-modulated radiotherapy yielded higher PTV V45 (volume that receives ≥45 Gy) (p < 0.001) than 3D-CRT. No difference in V20 was seen in the right (p = 0.9) and left (p 0.3) kidneys, but the liver mean dose (p < 0.001) was superior with IMRT. For the external audit, IMRT-C (p = 0.002) and IMRT-P (p < 0.001) achieved significantly lower left kidney V20 than IMRT, and IMRT-P (p < 0.001) achieved lower right kidney V20 than IMRT. The IMRT-C (p = 0.003) but not IMRT-P (p = 0.6) had lower liver mean doses than IMRT. Conclusions: At our institution with early IMRT experience, IMRT improved PTV dose coverage and liver doses but not kidney doses. An external audit of IMRT plans showed that an experienced center can yield superior IMRT plans

  5. Induction Chemotherapy and Continuous Hyperfractionated Accelerated Radiotherapy (CHART) for Patients With Locally Advanced Inoperable Non-Small-Cell Lung Cancer: The MRC INCH Randomized Trial

    International Nuclear Information System (INIS)

    Hatton, Matthew; Nankivell, Matthew; Lyn, Ethan; Falk, Stephen; Pugh, Cheryl; Navani, Neal; Stephens, Richard; Parmar, Mahesh

    2011-01-01

    Purpose: Recent clinical trials and meta-analyses have shown that both CHART (continuous hyperfractionated accelerated radiation therapy) and induction chemotherapy offer a survival advantage over conventional radical radiotherapy for patients with inoperable non-small cell-lung cancer (NSCLC). This multicenter randomized controlled trial (INCH) was set up to assess the value of giving induction chemotherapy before CHART. Methods and Materials: Patients with histologically confirmed, inoperable, Stage I-III NSCLC were randomized to induction chemotherapy (ICT) (three cycles of cisplatin-based chemotherapy followed by CHART) or CHART alone. Results: Forty-six patients were randomized (23 in each treatment arm) from 9 UK centers. As a result of poor accrual, the trial was closed in December 2007. Twenty-eight patients were male, 28 had squamous cell histology, 34 were Stage IIIA or IIIB, and all baseline characteristics were well balanced between the two treatment arms. Seventeen (74%) of the 23 ICT patients completed the three cycles of chemotherapy. All 42 (22 CHART + 20 ICT) patients who received CHART completed the prescribed treatment. Median survival was 17 months in the CHART arm and 25 months in the ICT arm (hazard ratio of 0.60 [95% CI 0.31-1.16], p = 0.127). Grade 3 or 4 adverse events (mainly fatigue, dysphagia, breathlessness, and anorexia) were reported for 13 (57%) CHART and 13 (65%) ICT patients. Conclusions: This small randomized trial indicates that ICT followed by CHART is feasible and well tolerated. Despite closing early because of poor accrual, and so failing to show clear evidence of a survival benefit for the additional chemotherapy, the results suggest that CHART, and ICT before CHART, remain important options for the treatment of inoperable NSCLC and deserve further study.

  6. Exclusive image guided IMRT vs. radical prostatectomy followed by postoperative IMRT for localized prostate cancer: a matched-pair analysis based on risk-groups

    International Nuclear Information System (INIS)

    Azelie, Caroline; Créhange, Gilles; Gauthier, Mélanie; Mirjolet, Céline; Cormier, Luc; Martin, Etienne; Peignaux-Casasnovas, Karine; Truc, Gilles; Chamois, Jérôme; Maingon, Philippe

    2012-01-01

    To investigate whether patients treated for a localized prostate cancer (PCa) require a radical prostatectomy followed by postoperative radiotherapy or exclusive radiotherapy, in the modern era of image guided IMRT. 178 patients with PCa were referred for daily exclusive image guided IMRT (IG-IMRT) using an on-line 3D ultra-sound based system and 69 patients were referred for postoperative IMRT without image guidance after radical prostatectomy (RP + IMRT). Patients were matched in a 1:1 ratio according to their baseline risk group before any treatment. Late toxicity was scored using the CTV v3.0 scale. Biochemical failure was defined as a postoperative PSA ≤ 0.1 ng/mL followed by 1 consecutive rising PSA for the postoperative group of patients and by the Phoenix definition (nadir + 2 ng/mL) for the group of patients treated with exclusive radiotherapy. A total of 98 patients were matched (49:49). From the start of any treatment, the median follow-up was 56.6 months (CI 95% = [49.6-61.2], range [18.2-115.1]). No patient had late gastrointestinal grade ≥ 2 toxicity in the IG-IMRT group vs. 4% in the RP + IMRT group. Forty two percent of the patients in both groups had late grade ≥ 2 genitourinary toxicity. The 5-year FFF rates in the IG-IMRT group and in the RP + IMRT groups were 93.1% [80.0-97.8] and 76.5% [58.3-87.5], respectively (p = 0.031). Patients with a localized PCa treated with IG-IMRT had better oncological outcome than patients treated with RP + IMRT. Further improvements in postoperative IMRT using image guidance and dose escalation are urgently needed

  7. Compensating for the impact of non-stationary spherical air cavities on IMRT dose delivery in transverse magnetic fields

    NARCIS (Netherlands)

    Bol, G H; Lagendijk, J J W; Raaymakers, B W

    2015-01-01

    With the development of the 1.5 T MRI linear accelerator and the clinical introduction of the 0.35 T ViewRay™ system, delivering intensity-modulated radiotherapy (IMRT) in a transverse magnetic field becomes increasingly important. When delivering dose in the presence of a transverse magnetic field,

  8. IMRT for Image-Guided Single Vocal Cord Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Osman, Sarah O.S., E-mail: s.osman@erasmusmc.nl [Department of Radiation Oncology, Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Astreinidou, Eleftheria; Boer, Hans C.J. de; Keskin-Cambay, Fatma; Breedveld, Sebastiaan; Voet, Peter; Al-Mamgani, Abrahim; Heijmen, Ben J.M.; Levendag, Peter C. [Department of Radiation Oncology, Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands)

    2012-02-01

    Purpose: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. Methods and Materials: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. Results: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose {+-} standard deviation to the planning target volume was 67 {+-} 1 Gy. The contralateral vocal cord dose was reduced from 66 {+-} 1 Gy in the conventional plans to 39 {+-} 8 Gy and 36 {+-} 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. Conclusions: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.

  9. IMRT for Image-Guided Single Vocal Cord Irradiation

    International Nuclear Information System (INIS)

    Osman, Sarah O.S.; Astreinidou, Eleftheria; Boer, Hans C.J. de; Keskin-Cambay, Fatma; Breedveld, Sebastiaan; Voet, Peter; Al-Mamgani, Abrahim; Heijmen, Ben J.M.; Levendag, Peter C.

    2012-01-01

    Purpose: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. Methods and Materials: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. Results: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose ± standard deviation to the planning target volume was 67 ± 1 Gy. The contralateral vocal cord dose was reduced from 66 ± 1 Gy in the conventional plans to 39 ± 8 Gy and 36 ± 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. Conclusions: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.

  10. Experimental IMRT breast dosimetry in a thorax phantom

    Energy Technology Data Exchange (ETDEWEB)

    Pimenta, Elsa B.; Campos, Tarcisio P.R.; Nogueira, Luciana B.; Lima, Andre C.S., E-mail: elsabpimenta@gmail.com, E-mail: tprcampos@pq.cnpq.br, E-mail: lucibn19@yahoo.com.br, E-mail: radioterapia.andre@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Centro de Tratamento em Radioterapia, Betim, MG (Brazil)

    2017-11-01

    Radiation therapy (RT) is an essential therapeutic method. RT is often used as adjuvant therapy in the treatment of breast cancer. The dose-volume restrictions of the organs at risk limit the prescribed dose to the target volume and biological and clinical effects may influence the final treatment outcome. The breast RT provides large risks to the adjacent organs and consequently the recommended dosimetry to the prescribed dose volume (PTV) is 50 Gy, lower than the most prescribed dose in other treatments (70-85 Gy). Such values implies in less tumor control compared to other sites. The present research proposal aimed to measure absorbed dose in a thorax phantom with synthetic breasts provided by an Intensity-Modulate Radiation Therapy (IMRT) protocol in a RT center. On the methodology, IMRT protocol was selected following recommendations from the Radiation Therapy Oncology Group (RTOG). Radiochromic films and a thorax simulator were prepared by the Ionizing Radiation Research Group (NRI). Dosimeters were calibrated on a selected linear accelerator (LINAC). The comparison of the dosimetry from treatment planning system (TPS), Xio (Elekta) and from experimental data was performed. The spatial distribution of the breast internal dose and in the adjacent organs was depicted by the experimental data. In the film's calibration, the quadratic polynomial fit presented a satisfactory coefficient. Two-dimensional dose profiles were obtained in the breast suggesting that films can supply details and information that TPS does not provide. At the phantom's dosimetry, the internal mean doses taken at the synthetic breast presented usual values above the prescribed dose, besides overall values were within the dosimetric MSKCC criterion. The non full reproduction of the build-up region in the films had occurred due to the asymmetrical positioning of the films in the inner breast, in addition to their non constant distance from the skin. The hot regions were present may

  11. Preoperative hyperfractionated radiotherapy with concurrent chemotherapy in resectable esophageal cancer

    International Nuclear Information System (INIS)

    Kim, Jong H.; Choi, Eun K.; Kim, Sung B.; Park, Seung I.; Kim, Dong K.; Song, Ho Y.; Jung, Hwoon Y.; Min, Young I.

    2001-01-01

    Purpose: To evaluate the local control rates, survival rates, and patterns of failure for esophageal cancer patients receiving preoperative concurrent chemotherapy and hyperfractionated radiotherapy followed by esophagectomy. Methods and Materials: From May 1993 through January 1997, 94 patients with resectable esophageal cancers received continuous hyperfractionated radiation (4,800 cGy/40 fx/4 weeks), with concurrent FP chemotherapy (5-FU 1 g/m 2 /day, days 2-6, 30-34, CDDP 60 mg/m 2 /day, days 1, 29) followed by esophagectomy 3-4 weeks later. If there was evidence of disease progression on preoperative re-evaluation work-up, or if the patient refused surgery, definitive chemoradiotherapy was delivered. Minimum follow-up time was 2 years. Results: All patients successfully completed preoperative treatment and were then followed until death. Fifty-three patients received surgical resection, and another 30 were treated with definitive chemoradiotherapy. Eleven patients did not receive further treatment. Among 91 patients who received clinical reevaluation, we observed 35 having clinical complete response (CR) (38.5%). Pathologic CR rate was 49% (26 patients). Overall survival rate was 59.8% at 2 years and 40.3% at 5 years. Median survival time was 32 months. In 83 patients who were treated with surgery or definitive chemoradiotherapy, the esophagectomy group showed significantly higher survival, disease-free survival, and local disease-free survival rates than those in the definitive chemoradiation group. Conclusion: Preoperative chemoradiotherapy in this trial showed improved clinical and pathologic tumor response and survival when compared to historical results. Patients who underwent esophagectomy following chemoradiation showed decreased local recurrence and improved survival and disease-free survival rates compared to the definitive chemoradiation group

  12. Concurrent hyperfractionated accelerated radiotherapy with 5-FU and once weekly cisplatin in locally advanced head and neck cancer. The 10-year results of a prospective phase II trial

    Energy Technology Data Exchange (ETDEWEB)

    Budach, V.; Boehmer, D.; Badakhshi, H.; Jahn, U.; Stromberger, C. [Campus Virchow Klinikum, Charite Universitaetsmedizin Berlin, Department for Radiooncology, Clinic for Radiooncology, Berlin (Germany); Becker, E.T. [Charite Universitaetsmedizin, Department of Otorhinolaryngology, Berlin (Germany); Wernecke, K.D. [Sostana Statistics GmbH, Charite Universitaetsmedizin Berlin, Berlin (Germany)

    2014-03-15

    In this study, the acute toxicity and long-term outcome of a hyperfractionated accelerated chemoradiation regimen with cisplatin/5-fluorouracil (5-FU) in patients with locally advanced squamous cell carcinomas of head and neck were evaluated. From 2000-2002, 38 patients with stage III (5.3 %) and stage IV (94.7 %) head and neck cancer were enrolled in a phase II study. Patients received hyperfractionated-accelerated radiotherapy with 72 Gy in 15 fractions of 2 Gy followed by 1.4 Gy twice daily with concurrent, continuous infusion 5-FU of 600 mg/m{sup 2} on days 1-5 and 6 cycles of weekly cisplatin (30 mg/m{sup 2}). Acute toxicities (CTCAEv2.0), locoregional control (LRC), metastases-free (MFS), and overall survival (OS) were analyzed and exploratively compared with the ARO 95-06 trial. Median follow-up was 11.4 years (95 % CI 8.6-14.2) and mean dose 71.6 Gy. Of the patients, 82 % had 6 (n = 15) or 5 (n = 16) cycles of cisplatin, 5 and 2 patients received 4 and 3 cycles, respectively. Grade 3 anemia, leukopenia, and thrombocytopenia were observed in 15.8, 15.8, and 2.6 %, respectively. Grade 3 mucositis in 50 %, grade 3 and 4 dysphagia in 55 and 13 %. The 2-, 5-, and 10-year LRC was 65, 53.6, and 48.2 %, the MFS was 77.5, 66.7, and 57.2 % and the OS 59.6, 29.2, and 15 %, respectively. Chemoradiation with 5-FU and cisplatin seems feasible and superior in terms of LRC and OS to the ARO 95-06C-HART arm at 2 years. However, this did not persist at the 5- and 10-year follow-ups. (orig.) [German] Untersuchung der Akuttoxizitaet und des Langzeitueberlebens einer hyperfraktioniert-akzelerierten simultanen Radiochemotherapie mit Cisplatin/5-Fluorouracil (5-FU) bei Patienten mit lokal fortgeschrittenen Kopf-Hals-Tumoren. Von 2000 bis 2002 wurden 38 Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region im Stadium III (5,3 %) und IV (94,7 %) eingeschlossen. Es erfolgte eine simultane hyperfraktionierte akzelerierte Radiochemotherapie mit 72 Gy in 15 Fraktionen a 2 Gy

  13. SU-F-T-271: Comparing IMRT QA Pass Rates Before and After MLC Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Mazza, A; Perrin, D; Fontenot, J [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States)

    2016-06-15

    Purpose: To compare IMRT QA pass rates before and after an in-house MLC leaf calibration procedure. Methods: The MLC leaves and backup jaws on four Elekta linear accelerators with MLCi2 heads were calibrated using the EPID-based RIT Hancock Test as the means for evaluation. The MLCs were considered to be successfully calibrated when they could pass the Hancock Test with criteria of 1 mm jaw position tolerance, and 1 mm leaf position tolerance. IMRT QA results were collected pre- and postcalibration and analyzed using gamma analysis with 3%/3mm DTA criteria. AAPM TG-119 test plans were also compared pre- and post-calibration, at both 2%/2mm DTA and 3%/3mm DTA. Results: A weighted average was performed on the results for all four linear accelerators. The pre-calibration IMRT QA pass rate was 98.3 ± 0.1%, compared with the post-calibration pass rate of 98.5 ± 0.1%. The TG-119 test plan results showed more of an improvement, particularly at the 2%/2mm criteria. The averaged results were 89.1% pre and 96.1% post for the C-shape plan, 94.8% pre and 97.1% post for the multi-target plan, 98.6% pre and 99.7% post for the prostate plan, 94.7% pre and 94.8% post for the head/neck plan. Conclusion: The patient QA results did not show statistically significant improvement at the 3%/3mm DTA criteria after the MLC calibration procedure. However, the TG-119 test cases did show significant improvement at the 2%/2mm level.

  14. Dosimetry of parotid glands in IMRT plan of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lian Jiancheng; Yu Xinsheng; Jiang Guoliang

    2007-01-01

    Objective: To evaluate the effect of different intensity-modulated radiation therapy (IMRT) plan on the dosimetry of parotid in patients with nasopharyngeal carcinoma. Methods: Under the same constraints and objections, the IMRT plan of nasopharyngeal carcinoma with sparing unilateral parotid and the IMRT plan added plan tumor volume (PTV) margin for parotid gland was investigated. Results: Between conventional IMRT plan and the IMRT plan spared unilateral parotid, their target coverage, homogeneity index and conformal index of PTV 70 is similar. On PTV 60 , D min in the plan of sparing one parotid gland was more than that in normal IMRT plan (P 95 in the plan of sparing one parotid gland have improved (P 50%VOL and D mean of parotid gland were similar between the two plans. Between conventional IMRT plan and the IMRT plan added 2 or 3 mm margin for parotid gland, their target coverage, homogeneity index and conformal index of PTV 70 is similar. D min , D mean and D 95 of PTV 60 have decreased tendency from normal IMRT plan to 2 mm margin plan to 3 mm margin plan. D max of brainstem and spine cord have increased tendency from normal IMRT plan to 2 mm margin plan to 3 mm margin plan. Conclusions: The IMRT plan of nasopharyngeal carcinoma with sparing unilateral parotid may be adopted not to protect both two parotids, while PTV margin for parotid added as parotid move. (authors)

  15. Effect of single dose, fractionated, and hyperfractionated trunk irradiation on weight gain, respiration frequency, and survival in rats

    International Nuclear Information System (INIS)

    Kimler, B.F.; Giri, P.G.S.; Giri, U.P.; Cox, G.G.

    1986-01-01

    It is concluded that, in this rat trunk irradiation model, fractionation of a single dose into two equal doses separated by 4-6 h produced a sparing effect of approx. 5Gy as measured by delay in weight gain; approx. 4Gy as measured by increased respiration frequency; and approx. 6Gy as measured by survival. Fractionation into daily doses or hyperfractionation into twice-daily doses permitted an approximate doubling of the dose required for the same suppression of weight gain. For the respiration rates and survival endpoints, fractionation or hyperfractionation produced an even greater sparing effect since there was no increase in the respiration frequency at twice the doses that would produce changes if delivered within a few hours; and since essentially no lethality was observed at twice the doses that would kill 70%-100% of animals if delivered in one day. (UK)

  16. A Phase I Study of Chemoradiotherapy With Use of Involved-Field Conformal Radiotherapy and Accelerated Hyperfractionation for Stage III Non-Small Cell Lung Cancer: WJTOG 3305

    Energy Technology Data Exchange (ETDEWEB)

    Tada, Takuhito, E-mail: tada@msic.med.osaka-cu.ac.jp [Department of Radiology, Osaka City University Graduate School of Medicine, Osaka (Japan); Department of Radiology, Izumi Municipal Hospital, Izumi (Japan); Chiba, Yasutaka [Department of Environmental Medicine and Behavioural Science, Kinki University Faculty of Medicine, Osaka-sayama (Japan); Tsujino, Kayoko [Department of Radiation Oncology, Hyogo Cancer Center, Akashi (Japan); Fukuda, Haruyuki [Department of Radiology, Osaka Prefectural Medical Center for Respiratory and Allergic Diseases, Habikino (Japan); Nishimura, Yasumasa [Department of Radiation Oncology, Kinki University Faculty of Medicine, Osaka-sayama (Japan); Kokubo, Masaki [Division of Radiation Oncology, Institute of Biomedical Research and Innovation, Kobe (Japan); Negoro, Shunichi [Department of Medical Oncology, Hyogo Cancer Center, Akashi (Japan); Kudoh, Shinzoh [Department of Respiratory Medicine, Osaka City University Graduate School of Medicine, Osaka (Japan); Fukuoka, Masahiro [Department of Medical Oncology, Izumi Municipal Hospital, Izumi (Japan); Nakagawa, Kazuhiko [Department of Medical Oncology, Kinki University Faculty of Medicine, Osaka-sayama (Japan); Nakanishi, Yoichi [Research Institute for Disease of the Chest, Graduate School of Medical Science, Kyusyu University, Fukuoka (Japan)

    2012-05-01

    Purpose: A Phase I study to determine a recommended dose of thoracic radiotherapy using accelerated hyperfractionation for unresectable non-small-cell lung cancer was conducted. Methods and Materials: Patients with unresectable Stage III non-small-cell lung cancer were treated intravenously with carboplatin (area under the concentration curve 2) and paclitaxel (40 mg/m{sup 2}) on Days 1, 8, 15, and 22 with concurrent twice-daily thoracic radiotherapy (1.5 Gy per fraction) beginning on Day 1 followed by two cycles of consolidation chemotherapy using carboplatin (area under the concentration curve 5) and paclitaxel (200 mg/m{sup 2}). Total doses were 54 Gy in 36 fractions, 60 Gy in 40 fractions, 66 Gy in 44 fractions, and 72 Gy in 48 fractions at Levels 1 to 4. The dose-limiting toxicity, defined as Grade {>=}4 esophagitis and neutropenic fever and Grade {>=}3 other nonhematologic toxicities, was monitored for 90 days. Results: Of 26 patients enrolled, 22 patients were assessable for response and toxicity. When 4 patients entered Level 4, enrollment was closed to avoid severe late toxicities. Dose-limiting toxicities occurred in 3 patients. They were Grade 3 neuropathy at Level 1 and Level 3 and Grade 3 infection at Level 1. However, the maximum tolerated dose was not reached. The median survival time was 28.6 months for all patients. Conclusions: The maximum tolerated dose was not reached, although the dose of radiation was escalated to 72 Gy in 48 fractions. However, a dose of 66 Gy in 44 fractions was adopted for this study because late toxicity data were insufficient.

  17. A Phase I Study of Chemoradiotherapy With Use of Involved-Field Conformal Radiotherapy and Accelerated Hyperfractionation for Stage III Non-Small Cell Lung Cancer: WJTOG 3305

    International Nuclear Information System (INIS)

    Tada, Takuhito; Chiba, Yasutaka; Tsujino, Kayoko; Fukuda, Haruyuki; Nishimura, Yasumasa; Kokubo, Masaki; Negoro, Shunichi; Kudoh, Shinzoh; Fukuoka, Masahiro; Nakagawa, Kazuhiko; Nakanishi, Yoichi

    2012-01-01

    Purpose: A Phase I study to determine a recommended dose of thoracic radiotherapy using accelerated hyperfractionation for unresectable non–small-cell lung cancer was conducted. Methods and Materials: Patients with unresectable Stage III non–small-cell lung cancer were treated intravenously with carboplatin (area under the concentration curve 2) and paclitaxel (40 mg/m 2 ) on Days 1, 8, 15, and 22 with concurrent twice-daily thoracic radiotherapy (1.5 Gy per fraction) beginning on Day 1 followed by two cycles of consolidation chemotherapy using carboplatin (area under the concentration curve 5) and paclitaxel (200 mg/m 2 ). Total doses were 54 Gy in 36 fractions, 60 Gy in 40 fractions, 66 Gy in 44 fractions, and 72 Gy in 48 fractions at Levels 1 to 4. The dose-limiting toxicity, defined as Grade ≥4 esophagitis and neutropenic fever and Grade ≥3 other nonhematologic toxicities, was monitored for 90 days. Results: Of 26 patients enrolled, 22 patients were assessable for response and toxicity. When 4 patients entered Level 4, enrollment was closed to avoid severe late toxicities. Dose-limiting toxicities occurred in 3 patients. They were Grade 3 neuropathy at Level 1 and Level 3 and Grade 3 infection at Level 1. However, the maximum tolerated dose was not reached. The median survival time was 28.6 months for all patients. Conclusions: The maximum tolerated dose was not reached, although the dose of radiation was escalated to 72 Gy in 48 fractions. However, a dose of 66 Gy in 44 fractions was adopted for this study because late toxicity data were insufficient.

  18. Pre-trial quality assurance processes for an intensity-modulated radiation therapy (IMRT) trial: PARSPORT, a UK multicentre Phase III trial comparing conventional radiotherapy and parotid-sparing IMRT for locally advanced head and neck cancer.

    Science.gov (United States)

    Clark, C H; Miles, E A; Urbano, M T Guerrero; Bhide, S A; Bidmead, A M; Harrington, K J; Nutting, C M

    2009-07-01

    The purpose of this study was to compare conventional radiotherapy with parotid gland-sparing intensity-modulated radiation therapy (IMRT) using the PARSPORT trial. The validity of such a trial depends on the radiotherapy planning and delivery meeting a defined standard across all centres. At the outset, many of the centres had little or no experience of delivering IMRT; therefore, quality assurance processes were devised to ensure consistency and standardisation of all processes for comparison within the trial. The pre-trial quality assurance (QA) programme and results are described. Each centre undertook exercises in target volume definition and treatment planning, completed a resource questionnaire and produced a process document. Additionally, the QA team visited each participating centre. Each exercise had to be accepted before patients could be recruited into the trial. 10 centres successfully completed the quality assurance exercises. A range of treatment planning systems, linear accelerators and delivery methods were used for the planning exercises, and all the plans created reached the standard required for participation in this multicentre trial. All 10 participating centres achieved implementation of a comprehensive and robust IMRT programme for treatment of head and neck cancer.

  19. Thyroid dysfunction as a late effect in childhood medulloblastoma: a comparison of hyperfractionated versus conventionally fractionated craniospinal radiotherapy

    International Nuclear Information System (INIS)

    Ricardi, Umberto; Corrias, Andrea; Einaudi, Silvia; Genitori, Lorenzo; Sandri, Alessandro; Cordero Di Montezemolo, Luca; Besenzon, Luigi; Madon, Enrico; Urgesi, Alessandro

    2001-01-01

    Purpose: Primary hypothyroidism is a common sequela of craniospinal radiotherapy in the treatment of childhood medulloblastoma. Due to the strong radiobiologic rationale, hyperfractionation can reduce the delayed effects of radiation injury. Methods and Materials: The authors compared the incidence of thyroid dysfunction after conventionally fractionated radiotherapy (Group A, n=20 patients) vs. hyperfractionated radiotherapy (Group B, n=12 patients) in a group of pediatric patients with posterior fossa primitive neuroectodermal tumor (PNET). Results: The mean age at the time of tumor diagnosis was 7.4 years in Group A and 8.4 years in Group B. Thyroid function was evaluated yearly, with ultrasonographic examination every 2 years. The patients were followed after diagnosis for a mean of 10.8 years for Group A and 6.0 years for Group B. Approximately 80% of the Group A (16/20) and 33.3% of the Group B (4/12) patients developed primary hypothyroidism within a similar period after irradiation (4.2 vs. 3.5 years, respectively). Analysis by cumulative incidence function demonstrated a significant difference in the risk of developing thyroid dysfunction between these two groups of patients (p<0.05). Ultrasonography showed reduced thyroid volume in 7 Group A patients and structural changes in 21 patients (17 Group A, 4 Group B cases); a thyroid benign nodule was detected in 2 Group A patients. Conclusions: The current study findings suggest that the use of hyperfractionated craniospinal radiotherapy in the treatment of childhood medulloblastoma is associated with a lower risk of these patients' developing late thyroid dysfunction

  20. Software for simulating IMRT protocol

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Thelma C.F.; Campos, Tarcisio P.R. de, E-mail: tcff@ufmg.b, E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear

    2009-07-01

    The Intensity Modulated Radiation Therapy - IMRT is an advanced technique to cancer treatment widely used on oncology around the world. The present paper describes the SOFT-RT software which is a tool for simulating IMRT protocol. Also, it will be present a cerebral tumor case of studied in which three irradiation windows with distinct orientation were applied. The SOFT-RT collect and export data to MCNP code. This code simulates the photon transport on the voxel model. Later, a out-module from SOFT-RT import the results and express the dose-response superimposing dose and voxel model in a tree-dimensional graphic representation. The present paper address the IMRT software and its function as well a cerebral tumor case of studied is showed. The graphic interface of the SOFT-RT illustrates the example case. (author)

  1. Software for simulating IMRT protocol

    International Nuclear Information System (INIS)

    Fonseca, Thelma C.F.; Campos, Tarcisio P.R. de

    2009-01-01

    The Intensity Modulated Radiation Therapy - IMRT is an advanced technique to cancer treatment widely used on oncology around the world. The present paper describes the SOFT-RT software which is a tool for simulating IMRT protocol. Also, it will be present a cerebral tumor case of studied in which three irradiation windows with distinct orientation were applied. The SOFT-RT collect and export data to MCNP code. This code simulates the photon transport on the voxel model. Later, a out-module from SOFT-RT import the results and express the dose-response superimposing dose and voxel model in a tree-dimensional graphic representation. The present paper address the IMRT software and its function as well a cerebral tumor case of studied is showed. The graphic interface of the SOFT-RT illustrates the example case. (author)

  2. A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Oliver, Mike; Chen, Jeff; Wong, Eugene; Van Dyk, Jake; Perera, Francisco

    2007-01-01

    Purpose and background: Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast irradiation for their radiation conformity index, dose homogeneity index, and dose to organs at risk. Methods and materials: Small-field tangents, three-dimensional conformal radiation therapy, intensity-modulated radiation therapy and helical tomotherapy were compared for each of 15 patients (7 right, 8 left). One radiation conformity and two dose homogeneity indices were used to evaluate the dose to the target. The mean dose to organs at risk was also evaluated. Results: All proposed APBI techniques improved the conformity index significantly over whole breast tangents while maintaining dose homogeneity and without a significant increase in dose to organs at risk. Conclusion: The four-field IMRT plan produced the best dosimetric results; however this technique would require appropriate respiratory motion management. An alternative would be to use a four-field conformal technique that is less sensitive to the effects of respiratory motion

  3. IMRT delivery verification using a spiral phantom

    International Nuclear Information System (INIS)

    Richardson, Susan L.; Tome, Wolfgang A.; Orton, Nigel P.; McNutt, Todd R.; Paliwal, Bhudatt R.

    2003-01-01

    In this paper we report on the testing and verification of a system for IMRT delivery quality assurance that uses a cylindrical solid water phantom with a spiral trajectory for radiographic film placement. This spiral film technique provides more complete dosimetric verification of the entire IMRT treatment than perpendicular film methods, since it samples a three-dimensional dose subspace rather than using measurements at only one or two depths. As an example, the complete analysis of the predicted and measured spiral films is described for an intracranial IMRT treatment case. The results of this analysis are compared to those of a single field perpendicular film technique that is typically used for IMRT QA. The comparison demonstrates that both methods result in a dosimetric error within a clinical tolerance of 5%, however the spiral phantom QA technique provides a more complete dosimetric verification while being less time consuming. To independently verify the dosimetry obtained with the spiral film, the same IMRT treatment was delivered to a similar phantom in which LiF thermoluminescent dosimeters were arranged along the spiral trajectory. The maximum difference between the predicted and measured TLD data for the 1.8 Gy fraction was 0.06 Gy for a TLD located in a high dose gradient region. This further validates the ability of the spiral phantom QA process to accurately verify delivery of an IMRT plan

  4. An analysis of tolerance levels in IMRT quality assurance procedures

    International Nuclear Information System (INIS)

    Basran, Parminder S.; Woo, Milton K.

    2008-01-01

    Increased use of intensity modulated radiation therapy (IMRT) has resulted in increased efforts in patient quality assurance (QA). Software and detector systems intended to streamline the IMRT quality assurance process often report metrics, such as percent discrepancies between measured and computed doses, which can be compared to benchmark or threshold values. The purpose of this work is to examine the relationships between two different types of IMRT QA processes in order to define, or refine, appropriate tolerances values. For 115 IMRT plans delivered in a 3 month period, we examine the discrepancies between (a) the treatment planning system (TPS) and results from a commercial independent monitor unit (MU) calculation program; (b) TPS and results from a commercial diode-array measurement system; and (c) the independent MU calculation and the diode-array measurements. Statistical tests were performed to assess significance in the IMRT QA results for different disease site and machine models. There is no evidence that the average total dose discrepancy in the monitor unit calculation depends on the disease site. Second, the discrepancies in the two IMRT QA methods are independent: there is no evidence that a better --or worse--monitor unit validation result is related to a better--or worse--diode-array measurement result. Third, there is marginal benefit in repeating the independent MU calculation with a more suitable dose point, if the initial IMRT QA failed a certain tolerance. Based on these findings, the authors conclude at some acceptable tolerances based on disease site and IMRT QA method. Specifically, monitor unit validations are expected to have a total dose discrepancy of 3% overall, and 5% per beam, independent of disease site. Diode array measurements are expected to have a total absolute dose discrepancy of 3% overall, and 3% per beam, independent of disease site. The percent of pixels exceeding a 3% and 3 mm threshold in a gamma analysis should be

  5. AP-PA field orientation followed by IMRT reduces lung exposure in comparison to conventional 3D conformal and sole IMRT in centrally located lung tumors

    Directory of Open Access Journals (Sweden)

    Soyfer Viacheslav

    2012-02-01

    Full Text Available Abstract Little attention has been paid to the fact that intensity modulated radiation therapy (IMRT techniques do not easily enable treatment with opposed beams. Three treatment plans (3 D conformal, IMRT, and combined (anterior-posterior-posterio-anterior (AP-PA + IMRT of 7 patients with centrally-located lung cancer were compared for exposure of lung, spinal cord and esophagus. Combined IMRT and AP-PA techniques offer better lung tissue sparing compared to plans predicated solely on IMRT for centrally-located lung tumors.

  6. Radiation efficacy and biological risk from whole-breast irradiation via intensity modulated radiation therapy (IMRT)

    Science.gov (United States)

    Desantis, David M.

    Radiotherapy is an established modality for women with breast cancer. During the delivery of external beam radiation to the breast, leakage, scattered x-rays from the patient and the linear accelerator also expose healthy tissues and organs outside of the breast, thereby increasing the patient's whole-body dose, which then increases the chance of developing a secondary, radiation-induced cancer. Generally, there are three IntensityModulated Radiotherapy (IMRT) delivery techniques from a conventional linear accelerator; forward planned (FMLC), inverse planned 'sliding window' (DMLC), and inverse planned 'step-and-shoot' (SMLC). The goal of this study was to determine which of these three techniques delivers an optimal dose to the breast with the least chance of causing a fatal, secondary, radiation-induced cancer. A conventional, non-IMRT, 'Wedge' plan also was compared. Computerized Tomography (CT) data sets for both a large and small sized patient were used in this study. With Varian's Eclipse AAA algorithm, the organ doses specified in the revised ICRP 60 publication were used to calculate the whole-body dose. Also, an anthropomorphic phantom was irradiated with thermoluminescent dosimeters (TLD) at each organ site for measured doses. The risk coefficient from the Biological Effects of Ionizing Radiation (BEIR) VII report of 4.69 x 10-2 deaths per Gy was used to convert whole-body dose to risk of a fatal, secondary, radiation-induced cancer. The FMLC IMRT delivered superior tumor coverage over the 3D conventional plan and the inverse DMLC or SMLC treatment plans delivered clinically equivalent tumor coverage. However, the FMLC plan had the least likelihood of inadvertently causing a fatal, secondary, radiation-induced cancer compared to the inverse DMLC, SMLC, and Wedge plans.

  7. Planner concepts in IMRT planning

    International Nuclear Information System (INIS)

    Sahoo, Suvendu Kr.; Rath, A.K.; Patnaik, S.; Mishra, S.K.

    2008-01-01

    IMRT is the most sophisticated, innovative, three- dimensional conformal radiation treatment that delivers highly focused radiation with minimal impact to surrounding normal tissue. As it is a computer control technique, the planar should have adequate knowledge to execute the plan in proper way other wise it is very difficult to get the optimal plan. In this article we want to high light, planner should have the basic concepts before starting the IMRT planning

  8. SU-E-T-83: A Study On Evaluating the Directional Dependency of 2D Seven 29 Ion Chamber Array Clinically with Different IMRT Plans

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Syam [Malabar Cancer Centre, Kannur, Kerala (India); Aswathi, C.P. [University of Calicut, Calicut, Kerala (India)

    2015-06-15

    Purpose: To evaluate the directional dependency of 2D seven 29 ion chamber array clinically with different IMRT plans. Methods: 25 patients already treated with IMRT plans were selected for the study. Verification plans were created for each treatment plan in eclipse 10 treatment planning system using the AAA algorithm with the 2D array and the Octavius CT phantom. Verification plans were done 2 times for a single patient. First plan with real IMRT (plan-related approach) and second plan with zero degree gantry angle (field-related approach). Measurements were performed on a Varian Clinac-iX, linear accelerator equipped with a millennium 120 multileaf collimator. Fluence was measured for all the delivered plans and analyzed using the verisoft software. Comparison was done by selecting the fluence delivered in static gantry (zero degree gantry) versus IMRT with real gantry angles. Results: The gamma pass percentage is greater than 97 % for all IMRT delivered with zero gantry angle and between 95%–98% for real gantry angles. Dose difference between the TPS calculated and measured for IMRT delivered with zero gantry angle was found to be between (0.03 to 0.06Gy) and with real gantry angles between (0.02 to 0.05Gy). There is a significant difference between the gamma analysis between the zero degree and true angle with a significance of 0.002. Standard deviation of gamma pass percentage between the IMRT plans with zero gantry angle was 0.68 and for IMRT with true gantry angle was found to be 0.74. Conclusion: The gamma analysis for IMRT with zero degree gantry angles shows higher pass percentage than IMRT delivered with true gantry angles. Verification plans delivered with true gantry angles lower the verification accuracy when 2D array is used for measurement.

  9. Quality of Survival and Growth in Children and Young Adults in the PNET4 European Controlled Trial of Hyperfractionated Versus Conventional Radiation Therapy for Standard-Risk Medulloblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, Colin, E-mail: crk1@soton.ac.uk [University of Southampton Faculty of Medicine and University Hospital Southampton National Health Service Foundation Trust, Southampton (United Kingdom); Bull, Kim [University of Southampton Faculty of Medicine and University Hospital Southampton National Health Service Foundation Trust, Southampton (United Kingdom); Chevignard, Mathilde [Hôpitaux de Saint Maurice, Saint Maurice (France); Neurophysiology, University of Pierre et Marie-Curie Paris 6, Paris (France); Culliford, David [University of Southampton Faculty of Medicine and University Hospital Southampton National Health Service Foundation Trust, Southampton (United Kingdom); Dörr, Helmuth G. [Kinder- und Jugendklinik der Universität Erlangen, Erlangen (Germany); Doz, François [Institut Curie and University Paris Descartes, Sorbonne Paris Cité (France); Kortmann, Rolf-Dieter [Department of Radiation Therapy, University of Leipzig, Leipzig (Germany); Lannering, Birgitta [Department of Pediatrics, The Sahlgren Academy, University of Gothenburg, Gothenburg (Sweden); Massimino, Maura [Fondazione Istituto di Ricovero e Cura a Carattere Scientifico IRCCS Istituto Nazionale dei Tumori, Milan (Italy); Navajas Gutiérrez, Aurora [Hospital Universitario Cruces, Baracaldo-Vizcaya (Spain); Rutkowski, Stefan [University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Spoudeas, Helen A. [Center for Pediatric Endocrinology, University College London, London (United Kingdom); Calaminus, Gabriele [Pediatric Oncology, University of Muenster, Muenster (Germany)

    2014-02-01

    Purpose: To compare quality of survival in “standard-risk” medulloblastoma after hyperfractionated radiation therapy of the central nervous system with that after standard radiation therapy, combined with a chemotherapy regimen common to both treatment arms, in the PNET4 randomised controlled trial. Methods and Materials: Participants in the PNET4 trial and their parents/caregivers in 7 participating anonymized countries completed standardized questionnaires in their own language on executive function, health status, behavior, health-related quality of life, and medical, educational, employment, and social information. Pre- and postoperative neurologic status and serial heights and weights were also recorded. Results: Data were provided by 151 of 244 eligible survivors (62%) at a median age at assessment of 15.2 years and median interval from diagnosis of 5.8 years. Compared with standard radiation therapy, hyperfractionated radiation therapy was associated with lower (ie, better) z-scores for executive function in all participants (mean intergroup difference 0.48 SDs, 95% confidence interval 0.16-0.81, P=.004), but health status, behavioral difficulties, and health-related quality of life z-scores were similar in the 2 treatment arms. Data on hearing impairment were equivocal. Hyperfractionated radiation therapy was also associated with greater decrement in height z-scores (mean intergroup difference 0.43 SDs, 95% confidence interval 0.10-0.76, P=.011). Conclusions: Hyperfractionated radiation therapy was associated with better executive function and worse growth but without accompanying change in health status, behavior, or quality of life.

  10. Quality of Survival and Growth in Children and Young Adults in the PNET4 European Controlled Trial of Hyperfractionated Versus Conventional Radiation Therapy for Standard-Risk Medulloblastoma

    International Nuclear Information System (INIS)

    Kennedy, Colin; Bull, Kim; Chevignard, Mathilde; Culliford, David; Dörr, Helmuth G.; Doz, François; Kortmann, Rolf-Dieter; Lannering, Birgitta; Massimino, Maura; Navajas Gutiérrez, Aurora; Rutkowski, Stefan; Spoudeas, Helen A.; Calaminus, Gabriele

    2014-01-01

    Purpose: To compare quality of survival in “standard-risk” medulloblastoma after hyperfractionated radiation therapy of the central nervous system with that after standard radiation therapy, combined with a chemotherapy regimen common to both treatment arms, in the PNET4 randomised controlled trial. Methods and Materials: Participants in the PNET4 trial and their parents/caregivers in 7 participating anonymized countries completed standardized questionnaires in their own language on executive function, health status, behavior, health-related quality of life, and medical, educational, employment, and social information. Pre- and postoperative neurologic status and serial heights and weights were also recorded. Results: Data were provided by 151 of 244 eligible survivors (62%) at a median age at assessment of 15.2 years and median interval from diagnosis of 5.8 years. Compared with standard radiation therapy, hyperfractionated radiation therapy was associated with lower (ie, better) z-scores for executive function in all participants (mean intergroup difference 0.48 SDs, 95% confidence interval 0.16-0.81, P=.004), but health status, behavioral difficulties, and health-related quality of life z-scores were similar in the 2 treatment arms. Data on hearing impairment were equivocal. Hyperfractionated radiation therapy was also associated with greater decrement in height z-scores (mean intergroup difference 0.43 SDs, 95% confidence interval 0.10-0.76, P=.011). Conclusions: Hyperfractionated radiation therapy was associated with better executive function and worse growth but without accompanying change in health status, behavior, or quality of life

  11. Quality of survival and growth in children and young adults in the PNET4 European controlled trial of hyperfractionated versus conventional radiation therapy for standard-risk medulloblastoma.

    Science.gov (United States)

    Kennedy, Colin; Bull, Kim; Chevignard, Mathilde; Culliford, David; Dörr, Helmuth G; Doz, François; Kortmann, Rolf-Dieter; Lannering, Birgitta; Massimino, Maura; Navajas Gutiérrez, Aurora; Rutkowski, Stefan; Spoudeas, Helen A; Calaminus, Gabriele

    2014-02-01

    To compare quality of survival in "standard-risk" medulloblastoma after hyperfractionated radiation therapy of the central nervous system with that after standard radiation therapy, combined with a chemotherapy regimen common to both treatment arms, in the PNET4 randomised controlled trial. Participants in the PNET4 trial and their parents/caregivers in 7 participating anonymized countries completed standardized questionnaires in their own language on executive function, health status, behavior, health-related quality of life, and medical, educational, employment, and social information. Pre- and postoperative neurologic status and serial heights and weights were also recorded. Data were provided by 151 of 244 eligible survivors (62%) at a median age at assessment of 15.2 years and median interval from diagnosis of 5.8 years. Compared with standard radiation therapy, hyperfractionated radiation therapy was associated with lower (ie, better) z-scores for executive function in all participants (mean intergroup difference 0.48 SDs, 95% confidence interval 0.16-0.81, P=.004), but health status, behavioral difficulties, and health-related quality of life z-scores were similar in the 2 treatment arms. Data on hearing impairment were equivocal. Hyperfractionated radiation therapy was also associated with greater decrement in height z-scores (mean intergroup difference 0.43 SDs, 95% confidence interval 0.10-0.76, P=.011). Hyperfractionated radiation therapy was associated with better executive function and worse growth but without accompanying change in health status, behavior, or quality of life. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Phase I Trial of Gross Total Resection, Permanent Iodine-125 Brachytherapy, and Hyperfractionated Radiotherapy for Newly Diagnosed Glioblastoma Multiforme

    International Nuclear Information System (INIS)

    Chen, Allen M.; Chang, Susan; Pouliot, Jean; Sneed, Penny K.; Prados, Michael D.; Lamborn, Kathleen R.; Malec, Mary K.; McDermott, Michael W.; Berger, Mitchell S.; Larson, David A.

    2007-01-01

    Purpose: To evaluate the feasibility of gross total resection and permanent I-125 brachytherapy followed by hyperfractionated radiotherapy for patients with newly diagnosed glioblastoma. Methods and Materials: From April 1999 to May 2002, 21 patients with glioblastoma multiforme were enrolled on a Phase I protocol investigating planned gross total resection and immediate placement of permanent I-125 seeds, followed by postoperative hyperfractionated radiotherapy to a dose of 60 Gy at 100 cGy b.i.d., 5 days per week. Median age and Karnofsky performance status were 50 years (range, 32-65 years) and 90 (range, 70-100), respectively. Toxicity was assessed according to Radiation Therapy Oncology Group criteria. Results: Eighteen patients completed treatment according to protocol. The median preoperative tumor volume on magnetic resonance imaging was 18.6 cm 3 (range, 4.4-41.2 cm 3 ). The median brachytherapy dose measured 5 mm radially outward from the resection cavity was 400 Gy (range, 200-600 Gy). Ten patients underwent 12 reoperations, with 11 of 12 reoperations demonstrating necrosis without evidence of tumor. Because of high toxicity, the study was terminated early. Median progression-free survival and overall survival were 57 and 114 weeks, respectively, but not significantly improved compared with historical patients treated at University of California, San Francisco, with gross total resection and radiotherapy without brachytherapy. Conclusions: Treatment with gross total resection and permanent I-125 brachytherapy followed by hyperfractionated radiotherapy as performed in this study results in high toxicity and reoperation rates, without demonstrated improvement in survival

  13. Statistical process control analysis for patient-specific IMRT and VMAT QA.

    Science.gov (United States)

    Sanghangthum, Taweap; Suriyapee, Sivalee; Srisatit, Somyot; Pawlicki, Todd

    2013-05-01

    This work applied statistical process control to establish the control limits of the % gamma pass of patient-specific intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA), and to evaluate the efficiency of the QA process by using the process capability index (Cpml). A total of 278 IMRT QA plans in nasopharyngeal carcinoma were measured with MapCHECK, while 159 VMAT QA plans were undertaken with ArcCHECK. Six megavolts with nine fields were used for the IMRT plan and 2.5 arcs were used to generate the VMAT plans. The gamma (3%/3 mm) criteria were used to evaluate the QA plans. The % gamma passes were plotted on a control chart. The first 50 data points were employed to calculate the control limits. The Cpml was calculated to evaluate the capability of the IMRT/VMAT QA process. The results showed higher systematic errors in IMRT QA than VMAT QA due to the more complicated setup used in IMRT QA. The variation of random errors was also larger in IMRT QA than VMAT QA because the VMAT plan has more continuity of dose distribution. The average % gamma pass was 93.7% ± 3.7% for IMRT and 96.7% ± 2.2% for VMAT. The Cpml value of IMRT QA was 1.60 and VMAT QA was 1.99, which implied that the VMAT QA process was more accurate than the IMRT QA process. Our lower control limit for % gamma pass of IMRT is 85.0%, while the limit for VMAT is 90%. Both the IMRT and VMAT QA processes are good quality because Cpml values are higher than 1.0.

  14. Definitive Upfront Stereotactic Ablative Radiotherapy Combined with Image-Guided, Intensity Modulated Radiotherapy (IG-IMRT or IG-IMRT Alone for Locally Advanced Non-Small Cell Lung Cancer.

    Directory of Open Access Journals (Sweden)

    Alexander Chi

    Full Text Available Image-guided (IG intensity-modulated radiotherapy (IMRT enables maximal tumor margin reduction for the sparing of organs at risk (OARs when used to treat locally advanced non-small cell lung cancer (NSCLC with definitive chemo-radiation. It also allows for the incorporation of stereotactic ablative radiotherapy (SABR into the treatment regimen. Here, we describe our initial experience in combining definitive upfront SABR to the primary lesion with chemo-radiation delivered with conventionally fractionated IG-IMRT to the remaining regional disease; along with clinical outcome following chemo-radiation with conventionally fractionated IG-IMRT alone in the treatment of locally advanced NSCLC.The clinical outcome of 29 patients with locally advanced NSCLC who underwent conventionally fractionated IG-IMRT, or definitive upfront SABR followed by IG-IMRT combined with chemotherapy (induction, concurrent, or both was retrospectively reviewed.After a median follow up of 23.7 months, the median overall survival (OS and progression-free survival (PFS were 19.8 and 11.3 months, respectively. The 2 year local, regional, and distant control was 60%, 62%, and 38%, respectively. No local failure was observed in 3 patients following SABR + IG-IMRT while 6/26 patients failed locally following IG-IMRT alone. SABR + IG-IMRT was well tolerated. No ≥ grade 3 radiation-related toxicity was observed.Definitive upfront SABR followed by IG-IMRT in selected patients with locally advanced NSCLC warrants further investigation in future clinical trials, while chemo-radiation with IG-IMRT alone was well tolerated.

  15. Compensating for the impact of non-stationary spherical air cavities on IMRT dose delivery in transverse magnetic fields

    International Nuclear Information System (INIS)

    Bol, G H; Lagendijk, J J W; Raaymakers, B W

    2015-01-01

    With the development of the 1.5 T MRI linear accelerator and the clinical introduction of the 0.35 T ViewRay™ system, delivering intensity-modulated radiotherapy (IMRT) in a transverse magnetic field becomes increasingly important. When delivering dose in the presence of a transverse magnetic field, one of the most prominent phenomena occurs around air cavities: the electron return effect (ERE). For stationary, spherical air cavities which are centrally located in the phantom, the ERE can be compensated by using opposing beams configurations in combination with IMRT. In this paper we investigate the effects of non-stationary spherical air cavities, centrally located within the target in a phantom containing no organs at risk, on IMRT dose delivery in 0.35 T and 1.5 T transverse magnetic fields by using Monte Carlo simulations. We show that IMRT can be used for compensating ERE around those air cavities, except for intrafraction appearing or disappearing air cavities. For these cases, gating or plan re-optimization should be used. We also analyzed the option of using IMRT plans optimized at 0 T to be delivered in the presence of 0.35 T and 1.5 T magnetic field. When delivering dose at 0.35 T, IMRT plans optimized at 0 T and 0.35 T perform equally well regarding ERE compensation. Within a 1.5 T environment, the 1.5 T optimized plans perform slightly better for the static and random intra- and interfraction air cavity movement cases than the 0 T optimized plans. For non-stationary spherical air cavities with a baseline shift (intra- and interfraction) the 0 T optimized plans perform better. These observations show the intrinsic ERE compensation by equidistant and opposing beam configurations for spherical air cavities within the target area. IMRT gives some additional compensation, but only in case of correct positioning of the air cavity according to the IMRT compensation. For intrafraction appearing or disappearing air cavities this correct

  16. Malignant astrocytoma: hyperfractionated and standard radiotherapy with chemotherapy in a randomized prospective clinical trial

    International Nuclear Information System (INIS)

    Payne, D.G.; Simpson, W.J.; Keen, C.; Platts, M.E.

    1982-01-01

    A prospective randomized trial of 157 patients with malignant astrocytomas (Grade III or IV) was carried out at a single institution. The minimization technique ensured balanced distribution of prognostic factors between the treatment groups. All received oral lomustine (CCNU, 80 mg/m 2 ) six weekly and hydroxyurea (HU, 3.5 gm/m 2 over 5 days) three weekly, for one year or until recurrence, with doses adjusted for myelosuppression. Patients were randomized to daily (5000 rad in 25 fractions (fr) in 5 weeks) or Q3h (every 3 hours) Cobalt 60 irradiation (3600-4000 rad in 36-40 fr of 100 rad each, given 4 fr per day at 3-hour intervals over two weeks). Steroid therapy (up to 16 mg day dexamethasone) was permitted. Complications were moderate and equivalent in the two groups. No significant survival or toxicity differences were seen between the two groups. Age, initial performance status, and extent of surgical resection were found to be significant (P<0.01) prognostic factors for survival. Median survival of the whole group was 48 weeks with a minimum follow-up of one year. There was no advantage to large radiation fields. The hyperfractionation and daily regimes had similar efficacy and toxicity. Hyperfractionation with chemotherapy offers a useful alternative approach in the management of this disease

  17. IMRT limits nephrotoxicity after chemoradiotherapy for gastric cancer

    International Nuclear Information System (INIS)

    Trip, Anouk Kirsten; Nijkamp, Jasper; Tinteren, Harm van; Cats, Annemieke; Boot, Henk; Jansen, Edwin Petrus Marianus; Verheij, Marcel

    2014-01-01

    Objective: This observational study compares the effect of different radiotherapy techniques on late nephrotoxicity after postoperative chemoradiotherapy for gastric cancer. Patients and methods: Dosimetric parameters were compared between AP–PA, 3D-conformal and IMRT techniques. Renal function was measured by 99m Tc-MAG-3 renography, glomerular filtration rate (GFR) and the development of hypertension. Mixed effects models were used to compare renal function over time. Results: Eighty-seven patients treated between 2002 and 2010 were included, AP–PA (n = 31), 3D-conformal (n = 25) and IMRT (n = 31), all 45 Gy in 25 fractions. Concurrent chemotherapy: 5FU/leucovorin (n = 4), capecitabine (n = 37), and capecitabine/cisplatin (n = 46). Median follow-up time was 4.7 years (range 0.2–8). With IMRT, the mean dose to the left kidney was significantly lower. Left kidney function decreased progressively in the total study population, however with IMRT this occurred at a lower rate. A dose–effect relationship was present between mean dose to the left kidney and the left kidney function. GFR decreased only moderately in time, which was not different between techniques. Six patients developed hypertension, of whom none in the IMRT group. Conclusions: This study confirms progressive late nephrotoxicity in patients treated with postoperative chemoradiotherapy by different techniques for gastric cancer. Nephrotoxicity was less severe with IMRT and should be considered the preferred technique

  18. IMRT limits nephrotoxicity after chemoradiotherapy for gastric cancer.

    Science.gov (United States)

    Trip, Anouk Kirsten; Nijkamp, Jasper; van Tinteren, Harm; Cats, Annemieke; Boot, Henk; Jansen, Edwin Petrus Marianus; Verheij, Marcel

    2014-08-01

    This observational study compares the effect of different radiotherapy techniques on late nephrotoxicity after postoperative chemoradiotherapy for gastric cancer. Dosimetric parameters were compared between AP-PA, 3D-conformal and IMRT techniques. Renal function was measured by (99m)Tc-MAG-3 renography, glomerular filtration rate (GFR) and the development of hypertension. Mixed effects models were used to compare renal function over time. Eighty-seven patients treated between 2002 and 2010 were included, AP-PA (n=31), 3D-conformal (n=25) and IMRT (n=31), all 45 Gy in 25 fractions. Concurrent chemotherapy: 5FU/leucovorin (n=4), capecitabine (n=37), and capecitabine/cisplatin (n=46). Median follow-up time was 4.7 years (range 0.2-8). With IMRT, the mean dose to the left kidney was significantly lower. Left kidney function decreased progressively in the total study population, however with IMRT this occurred at a lower rate. A dose-effect relationship was present between mean dose to the left kidney and the left kidney function. GFR decreased only moderately in time, which was not different between techniques. Six patients developed hypertension, of whom none in the IMRT group. This study confirms progressive late nephrotoxicity in patients treated with postoperative chemoradiotherapy by different techniques for gastric cancer. Nephrotoxicity was less severe with IMRT and should be considered the preferred technique. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Predictive value of the flow cytometric PCNA - assay (proliferating cell nuclear antigen) in head and neck tumors after accelerated-hyperfractionated radiochemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wenz, F; Lohr, F; Rudat, V; Dietz, A; Flentje, M; Wannenmacher, M

    1995-07-01

    Purpose/Objective: Proliferation of surviving tumor cells during fractionated radiotherapy may limit tumor control, especially in rapidly proliferating tumors. It has been widely accepted, that this may play a major role in head and neck tumors. Several methods for the assessment of tumor proliferation have been developed, however, most of them are either laborious, invasive or potentially toxic. Today, the gold standard is the flow cytometric BrdUrd assay. We present a flow cytometric method for detection of PCNA, which is an intranuclear proliferation associated protein, in solid human head and neck tumors and how these data correlate with outcome. Materials and Methods: Pretherapeutic biopsies of 20 inoperable patients with squamous cell carcinoma of the head and neck (T3-4N2M0) were examined. The tissue was disaggregated with pepsin/HCl, antibody staining was performed using the clone PC10. Biparametric flow cytometry was performed after a FITC conjugated secondary antibody and propidiumjodine staining was applied. The PCNA-index (i.e. percentage PCNA-positive cells), the DNA-index and the S-phase fraction (SPF, euploid tumors only) were determined. The therapy consisted of combined accelerated-hyperfractionated radiochemotherapy (66 Gy in 5 wks, concomittant boost of 1.6 Gy/d in wks 4+5, Carboplatin in wks 1+5). The median follow-up time was 14 mths (5 - 28), the clinical partners (V.R., A.D.) were 'blinded' towards the PCNA-values. Results: 13 patients suffered from disease progession and 11 died. The actuarial median survival and disease free survival (DFS) were 14.4 and 10.7 mths, respectively. The PCNA-values ranged from 3.2 to 70% (median 9%), there were 7 aneuploid and 13 euploid tumors. SFP in the euploid tumors ranged from 4 to 14.5% (median 10.5%). Neither SFP nor ploidy had a significant influence on the outcome. The patients were divided according to their PCNA-value in higher (n=10) and lower (n=10) than the median. The survival and DFS were 13

  20. Institutional Patient-specific IMRT QA Does Not Predict Unacceptable Plan Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Kry, Stephen F., E-mail: sfkry@mdanderson.org [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Molineu, Andrea [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kerns, James R.; Faught, Austin M.; Huang, Jessie Y.; Pulliam, Kiley B.; Tonigan, Jackie [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States); Alvarez, Paola [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Stingo, Francesco [The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States); Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Followill, David S. [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States)

    2014-12-01

    Purpose: To determine whether in-house patient-specific intensity modulated radiation therapy quality assurance (IMRT QA) results predict Imaging and Radiation Oncology Core (IROC)-Houston phantom results. Methods and Materials: IROC Houston's IMRT head and neck phantoms have been irradiated by numerous institutions as part of clinical trial credentialing. We retrospectively compared these phantom results with those of in-house IMRT QA (following the institution's clinical process) for 855 irradiations performed between 2003 and 2013. The sensitivity and specificity of IMRT QA to detect unacceptable or acceptable plans were determined relative to the IROC Houston phantom results. Additional analyses evaluated specific IMRT QA dosimeters and analysis methods. Results: IMRT QA universally showed poor sensitivity relative to the head and neck phantom, that is, poor ability to predict a failing IROC Houston phantom result. Depending on how the IMRT QA results were interpreted, overall sensitivity ranged from 2% to 18%. For different IMRT QA methods, sensitivity ranged from 3% to 54%. Although the observed sensitivity was particularly poor at clinical thresholds (eg 3% dose difference or 90% of pixels passing gamma), receiver operator characteristic analysis indicated that no threshold showed good sensitivity and specificity for the devices evaluated. Conclusions: IMRT QA is not a reasonable replacement for a credentialing phantom. Moreover, the particularly poor agreement between IMRT QA and the IROC Houston phantoms highlights surprising inconsistency in the QA process.

  1. Institutional Patient-specific IMRT QA Does Not Predict Unacceptable Plan Delivery

    International Nuclear Information System (INIS)

    Kry, Stephen F.; Molineu, Andrea; Kerns, James R.; Faught, Austin M.; Huang, Jessie Y.; Pulliam, Kiley B.; Tonigan, Jackie; Alvarez, Paola; Stingo, Francesco; Followill, David S.

    2014-01-01

    Purpose: To determine whether in-house patient-specific intensity modulated radiation therapy quality assurance (IMRT QA) results predict Imaging and Radiation Oncology Core (IROC)-Houston phantom results. Methods and Materials: IROC Houston's IMRT head and neck phantoms have been irradiated by numerous institutions as part of clinical trial credentialing. We retrospectively compared these phantom results with those of in-house IMRT QA (following the institution's clinical process) for 855 irradiations performed between 2003 and 2013. The sensitivity and specificity of IMRT QA to detect unacceptable or acceptable plans were determined relative to the IROC Houston phantom results. Additional analyses evaluated specific IMRT QA dosimeters and analysis methods. Results: IMRT QA universally showed poor sensitivity relative to the head and neck phantom, that is, poor ability to predict a failing IROC Houston phantom result. Depending on how the IMRT QA results were interpreted, overall sensitivity ranged from 2% to 18%. For different IMRT QA methods, sensitivity ranged from 3% to 54%. Although the observed sensitivity was particularly poor at clinical thresholds (eg 3% dose difference or 90% of pixels passing gamma), receiver operator characteristic analysis indicated that no threshold showed good sensitivity and specificity for the devices evaluated. Conclusions: IMRT QA is not a reasonable replacement for a credentialing phantom. Moreover, the particularly poor agreement between IMRT QA and the IROC Houston phantoms highlights surprising inconsistency in the QA process

  2. Incidence of interstitial pneumonia after hyperfractionated total body irradiation before autologous bone marrow/stem cell transplantation

    International Nuclear Information System (INIS)

    Lohr, F.; Schraube, P.; Wenz, F.; Flentje, M.; Kalle, K. von; Haas, R.; Hunstein, W.; Wannenmacher, M.

    1995-01-01

    Purpose/Objectives Interstitial pneumonia (IP) is a severe complication after allogenic bone marrow transplantation (BMT) with incidence rates between 10 % and 40 % in different series. It is a polyetiologic disease that occurs depending on age, graft vs. host disease (GvHD), CMV-status, total body irradiation (TBI) and immunosuppressive therapy after BMT. The effects of fractionation and dose rate are not entirely clear. This study evaluates the incidence of lethal IP after hyperfractionated TBI for autologous BMT or stem cell transplantation. Materials and Methods Between 1982 and 1992, 182 patients (60 % male, 40 % female) were treated with hyperfractionated total body irradiation (TBI) before autologous bone marrow transplantation. Main indications were leukemias and lymphomas (53 % AML, 21 % ALL, 22 % NHL, 4 % others) Median age was 30 ys (15 - 55 ys). A total dose of 14.4 Gy was applied using lung blocks (12 fractions of 1.2 Gy in 4 days, dose rate 7-18 cGy/min, lung dose 9 - 9.5 Gy). TBI was followed by cyclophosphamide (200 mg/kg). 72 % were treated with bone marrow transplantation, 28 % were treated with stem cell transplantation. Interstitial pneumonia was diagnosed clinically, radiologically and by autopsy. Results 4 patients died most likely of interstitial pneumonia. For another 12 patients interstitial pneumonia was not the most likely cause of death but could not be excluded. Thus, the incidence of lethal IP was at least 2.2 % but certainly below 8.8 %. Conclusion Lethal interstitial pneumonia is a rare complication after total body irradiation before autologous bone marrow transplantation in this large, homogeously treated series. In the autologous setting, total doses of 14.4 Gy can be applied with a low risk for developing interstitial pneumonia if hyperfractionation and lung blocks are used. This falls in line with data from series with identical twins or t-cell depleted marrow and smaller, less homogeneous autologous transplant studies. Thus

  3. Automated IMRT planning with regional optimization using planning scripts.

    Science.gov (United States)

    Xhaferllari, Ilma; Wong, Eugene; Bzdusek, Karl; Lock, Michael; Chen, Jeff

    2013-01-07

    Intensity-modulated radiation therapy (IMRT) has become a standard technique in radiation therapy for treating different types of cancers. Various class solutions have been developed for simple cases (e.g., localized prostate, whole breast) to generate IMRT plans efficiently. However, for more complex cases (e.g., head and neck, pelvic nodes), it can be time-consuming for a planner to generate optimized IMRT plans. To generate optimal plans in these more complex cases which generally have multiple target volumes and organs at risk, it is often required to have additional IMRT optimization structures such as dose limiting ring structures, adjust beam geometry, select inverse planning objectives and associated weights, and additional IMRT objectives to reduce cold and hot spots in the dose distribution. These parameters are generally manually adjusted with a repeated trial and error approach during the optimization process. To improve IMRT planning efficiency in these more complex cases, an iterative method that incorporates some of these adjustment processes automatically in a planning script is designed, implemented, and validated. In particular, regional optimization has been implemented in an iterative way to reduce various hot or cold spots during the optimization process that begins with defining and automatic segmentation of hot and cold spots, introducing new objectives and their relative weights into inverse planning, and turn this into an iterative process with termination criteria. The method has been applied to three clinical sites: prostate with pelvic nodes, head and neck, and anal canal cancers, and has shown to reduce IMRT planning time significantly for clinical applications with improved plan quality. The IMRT planning scripts have been used for more than 500 clinical cases.

  4. Phantoms for IMRT dose distribution measurement and treatment verification

    International Nuclear Information System (INIS)

    Low, Daniel A.; Gerber, Russell L.; Mutic, Sasa; Purdy, James A.

    1998-01-01

    Background: The verification of intensity-modulated radiation therapy (IMRT) patient treatment dose distributions is currently based on custom-built or modified dose measurement phantoms. The only commercially available IMRT treatment planning and delivery system (Peacock, NOMOS Corp.) is supplied with a film phantom that allows accurate spatial localization of the dose distribution using radiographic film. However, measurements using other dosimeters are necessary for the thorough verification of IMRT. Methods: We have developed a phantom to enable dose measurements using a cylindrical ionization chamber and the localization of prescription isodose curves using a matrix of thermoluminescent dosimetry (TLD) chips. The external phantom cross-section is identical to that of the commercial phantom, to allow direct comparisons of measurements. A supplementary phantom has been fabricated to verify the IMRT dose distributions for pelvis treatments. Results: To date, this phantom has been used for the verification of IMRT dose distributions for head and neck and prostate cancer treatments. Designs are also presented for a phantom insert to be used with polymerizing gels (e.g., BANG-2) to obtain volumetric dose distribution measurements. Conclusion: The phantoms have proven useful in the quantitative evaluation of IMRT treatments

  5. SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification

    Energy Technology Data Exchange (ETDEWEB)

    Stathakis, S; Defoor, D; Linden, P; Kirby, N; Papanikolaou, N [University of Texas HSC SA, San Antonio, TX (United States)

    2015-06-15

    Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was used for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.

  6. Lhermitte's Sign Developing after IMRT for Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Dong C. Lim

    2010-01-01

    Full Text Available Background. Lhermitte's sign (LS is a benign form of myelopathy with neck flexion producing an unpleasant electric-shock sensation radiating down the extremities. Although rare, it can occur after head and neck radiotherapy. Results. We report a case of Lhermitte's developing after curative intensity-modulated radiotherapy (IMRT for a patient with locoregionally advanced oropharyngeal cancer. IMRT delivers a conformal dose of radiation in head and neck cancer resulting in a gradient of radiation dose throughout the spinal cord. Using IMRT, more dose is delivered to the anterior spinal cord than the posterior cord. Conclusions. Lhermitte's sign can develop after IMRT for head and neck cancer. We propose an anterior spinal cord structure, the spinothalamic tract to be the target of IMRT-caused LS.

  7. Final Results of a Randomized Phase 2 Trial Investigating the Addition of Cetuximab to Induction Chemotherapy and Accelerated or Hyperfractionated Chemoradiation for Locoregionally Advanced Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Seiwert, Tanguy Y., E-mail: tseiwert@medicine.bsd.uchicago.edu [Departments of Medicine, University of Chicago, Chicago, Illinois (United States); Melotek, James M. [Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois (United States); Blair, Elizabeth A. [Department of Otolaryngology, University of Chicago, Chicago, Illinois (United States); Stenson, Kerstin M. [Department of Otolaryngology, Rush University, Chicago, Illinois (United States); Salama, Joseph K. [Department of Radiation Oncology, Duke University, Durham, North Carolina (United States); Witt, Mary Ellyn [Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois (United States); Brisson, Ryan J.; Chawla, Apoorva; Dekker, Allison [Departments of Medicine, University of Chicago, Chicago, Illinois (United States); Lingen, Mark W. [Department of Pathology, University of Chicago, Chicago, Illinois (United States); Kocherginsky, Masha [Department of Public Health Sciences, University of Chicago, Chicago, Illinois (United States); Villaflor, Victoria M. [Departments of Medicine, University of Chicago, Chicago, Illinois (United States); Cohen, Ezra E.W. [Moores Cancer Center, University of California, San Diego, San Diego, California (United States); Haraf, Daniel J. [Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois (United States); Vokes, Everett E. [Departments of Medicine, University of Chicago, Chicago, Illinois (United States)

    2016-09-01

    Purpose: The role of cetuximab in the treatment of locoregionally advanced head and neck squamous cell cancer (LA-HNSCC) remains poorly defined. In this phase 2 randomized study, we investigated the addition of cetuximab to both induction chemotherapy (IC) and hyperfractionated or accelerated chemoradiation. Methods and Materials: Patients with LA-HNSCC were randomized to receive 2 cycles of weekly IC (cetuximab, paclitaxel, carboplatin) and either Cetux-FHX (concurrent cetuximab, 5-fluorouracil, hydroxyurea, and 1.5 Gy twice-daily radiation therapy every other week to 75 Gy) or Cetux-PX (cetuximab, cisplatin, and accelerated radiation therapy with delayed concomitant boost to 72 Gy in 42 fractions). The primary endpoint was progression-free survival (PFS), with superiority compared with historical control achieved if either arm had 2-year PFS ≥70%. Results: 110 patients were randomly assigned to either Cetux-FHX (n=57) or Cetux-PX (n=53). The overall response rate to IC was 91%. Severe toxicity on IC was limited to rash (23% grade ≥3) and myelosuppression (38% grade ≥3 neutropenia). The 2-year rates of PFS for both Cetux-FHX (82.5%) and Cetux-PX (84.9%) were significantly higher than for historical control (P<.001). The 2-year overall survival (OS) was 91.2% for Cetux-FHX and 94.3% for Cetux-PX. With a median follow-up time of 72 months, there were no significant differences in PFS (P=.35) or OS (P=.15) between the treatment arms. The late outcomes for the entire cohort included 5-year PFS, OS, locoregional failure, and distant metastasis rates of 74.1%, 80.3%, 15.7%, and 7.4%, respectively. The 5-year PFS and OS were 84.4% and 91.3%, respectively, among human papillomavirus (HPV)-positive patients and 65.9% and 72.5%, respectively, among HPV-negative patients. Conclusions: The addition of cetuximab to IC and chemoradiation was tolerable and produced long-term control of LA-HNSCC, particularly among poor-prognosis HPV-negative patients. Further

  8. Final Results of a Randomized Phase 2 Trial Investigating the Addition of Cetuximab to Induction Chemotherapy and Accelerated or Hyperfractionated Chemoradiation for Locoregionally Advanced Head and Neck Cancer

    International Nuclear Information System (INIS)

    Seiwert, Tanguy Y.; Melotek, James M.; Blair, Elizabeth A.; Stenson, Kerstin M.; Salama, Joseph K.; Witt, Mary Ellyn; Brisson, Ryan J.; Chawla, Apoorva; Dekker, Allison; Lingen, Mark W.; Kocherginsky, Masha; Villaflor, Victoria M.; Cohen, Ezra E.W.; Haraf, Daniel J.; Vokes, Everett E.

    2016-01-01

    Purpose: The role of cetuximab in the treatment of locoregionally advanced head and neck squamous cell cancer (LA-HNSCC) remains poorly defined. In this phase 2 randomized study, we investigated the addition of cetuximab to both induction chemotherapy (IC) and hyperfractionated or accelerated chemoradiation. Methods and Materials: Patients with LA-HNSCC were randomized to receive 2 cycles of weekly IC (cetuximab, paclitaxel, carboplatin) and either Cetux-FHX (concurrent cetuximab, 5-fluorouracil, hydroxyurea, and 1.5 Gy twice-daily radiation therapy every other week to 75 Gy) or Cetux-PX (cetuximab, cisplatin, and accelerated radiation therapy with delayed concomitant boost to 72 Gy in 42 fractions). The primary endpoint was progression-free survival (PFS), with superiority compared with historical control achieved if either arm had 2-year PFS ≥70%. Results: 110 patients were randomly assigned to either Cetux-FHX (n=57) or Cetux-PX (n=53). The overall response rate to IC was 91%. Severe toxicity on IC was limited to rash (23% grade ≥3) and myelosuppression (38% grade ≥3 neutropenia). The 2-year rates of PFS for both Cetux-FHX (82.5%) and Cetux-PX (84.9%) were significantly higher than for historical control (P<.001). The 2-year overall survival (OS) was 91.2% for Cetux-FHX and 94.3% for Cetux-PX. With a median follow-up time of 72 months, there were no significant differences in PFS (P=.35) or OS (P=.15) between the treatment arms. The late outcomes for the entire cohort included 5-year PFS, OS, locoregional failure, and distant metastasis rates of 74.1%, 80.3%, 15.7%, and 7.4%, respectively. The 5-year PFS and OS were 84.4% and 91.3%, respectively, among human papillomavirus (HPV)-positive patients and 65.9% and 72.5%, respectively, among HPV-negative patients. Conclusions: The addition of cetuximab to IC and chemoradiation was tolerable and produced long-term control of LA-HNSCC, particularly among poor-prognosis HPV-negative patients. Further

  9. Intensity modulated radiotherapy (IMRT) with compensators

    International Nuclear Information System (INIS)

    Salz, H.; Wiezorek, T.; Scheithauer, M.; Kleen, W.; Schwedas, M.; Wendt, T.G.

    2002-01-01

    The irradiation with intensity-modulated fields is possible with static as well as dynamic methods. In our university hospital, the intensity-modulated radiotherapy (IMRT) with compensators was prepared and used for the first time for patient irradiation in July 2001. The compensators consist of a mixture of tin granulate and wax, which is filled in a milled negative mould. The treatment planning is performed with Helax-TMS (MDS Nordion). An additional software is used for editing the modulation matrix ('Modifix'). Before irradiation of the first patient, extensive measurements have been carried out in terms of quality assurance of treatment planning and production of compensators. The results of the verification measurements have shown that IMRT with compensators possesses high spatial and dosimetric exactness. The calculated dose distributions are applied correctly. The accuracy of the calculated monitor units is normally better than 3%; in small volumes, further dosimetric inaccuracies between calculated and measured dose distributions are mostly less than 3%. Therefore, the compensators contribute to the achievement of high-level IMRT even when apparatuses without MLC are used. This paper describes the use of the IMRT with compensators, presents the limits of this technology, and discusses the first practical experiences. (orig.) [de

  10. BENEFITS OF INTENSITY-MODULATED RADIOTHERAPY (IMRT IN PATIENTS WITH HEAD AND NECK MALIGNANCIES- A SINGLE INSTITUTION EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Sherry Seasor Abraham

    2017-09-01

    Full Text Available BACKGROUND Radiotherapy and surgery are the principal curative modalities in treatment of head and neck cancer. Conventional twodimensional and three-dimensional conformal radiotherapy result in significant side effects and altered quality of life. IntensityModulated Radiotherapy (IMRT can spare the normal tissues, while delivering a curative dose to the tumour-bearing tissues. This study reveals the role of IMRT in head and neck cancer in view of normal tissue sparing with good tumour control. MATERIALS AND METHODS Radical radiotherapy was given using linear accelerator up to a dose of 66 to 70 gray in 30 to 33 fractions (intensity-modulated radiotherapy with simultaneous integrated boost over 6 to 7 weeks to 56 eligible patients. Concurrent cisplatin was given to patients with locally-advanced disease up to a dose of 40 mg/m2 weekly once along with radiation. The patients were monitored weekly once during the treatment for acute skin and mucosal toxicities using the RTOG scoring criteria. After the treatment, locoregional response was assessed and recorded at 6 weeks, 3 months and 6 months intervals. RESULTS Severe skin toxicity (grade III or more was seen in approximately 7% patients. Severe mucosal toxicity (grade III or more was seen in approximately 80% of patients. IMRT technique showed better skin sparing compared to 3D conformal radiotherapy. Severe mucosal toxicity was slightly higher in this study due to the simultaneous integrated boost technique used for dose intensification to the mucosa, which results in better primary tumour control. At the end of 6 months, 75% patients achieved locoregional control and residual/recurrent disease was seen in 25% of patients. IMRT offered good locoregional control with less skin toxicity and acceptable mucosal toxicity. The results were similar to the previous study reports using IMRT. CONCLUSION IMRT is a better treatment option in locally-advanced head and neck malignancies providing good

  11. Planning issues for IMRT

    International Nuclear Information System (INIS)

    Hoban, P.; Schneider, M.; Smee, R.

    2001-01-01

    Full text: Despite the 'inverse planning' stage of an intensity modulated radiotherapy (IMRT) treatment there remains a large number of variables that can, and must, be set manually. These variables can significantly affect the quality of the dose distribution arrived at by the optimisation. Clinical IMRT planning with the Radionics XPlan system for micro-multileaf collimator (MMLC) delivery has allowed for important lessons to be learned regarding the best beam and organ configurations prior to optimisation of beamlet weights. Important user-definable variables are beam directions, organ parameters (dose goals/penalties), and the margin (if any) around the planning target volume (PTV) used to aid coverage. Conventional stereotactic radiotherapy (SRT) treatments typically involve non-coplanar beams since there is often an advantage in terms of cranial organ at risk (OAR) sparing. IMRT can also benefit from such a configuration. The balance between target coverage and OAR sparing is largely controlled by user-defined goal doses and penalties. Once optimisation has been performed, intensity maps can be discretised into a selected number of levels. Less levels means less field segments and thus a shorter treatment time. Although IMRT beams attempt to spare structures which are in the 'beam's eye view' (BEV) of the target volume, sparing is greater if beams which minimise the involvement of OARs in their view are used. It has been found that the use of a margin is an effective way to ensure adequate PTV coverage. Alternatively the PTV penalties can be made larger. The best result is often obtained by the use of a 3-4 mm margin, whose penalty for underdosage is somewhat less than that for the PTV. Discretising the intensity maps to 4 or 5 levels is typically a good balance between shortening treatment time and not overly degrading the dose distribution. Beam configuration is still an important step in IMRT planning, even though optimisation of intensity maps is

  12. Direct aperture optimization for IMRT using Monte Carlo generated beamlets

    International Nuclear Information System (INIS)

    Bergman, Alanah M.; Bush, Karl; Milette, Marie-Pierre; Popescu, I. Antoniu; Otto, Karl; Duzenli, Cheryl

    2006-01-01

    This work introduces an EGSnrc-based Monte Carlo (MC) beamlet does distribution matrix into a direct aperture optimization (DAO) algorithm for IMRT inverse planning. The technique is referred to as Monte Carlo-direct aperture optimization (MC-DAO). The goal is to assess if the combination of accurate Monte Carlo tissue inhomogeneity modeling and DAO inverse planning will improve the dose accuracy and treatment efficiency for treatment planning. Several authors have shown that the presence of small fields and/or inhomogeneous materials in IMRT treatment fields can cause dose calculation errors for algorithms that are unable to accurately model electronic disequilibrium. This issue may also affect the IMRT optimization process because the dose calculation algorithm may not properly model difficult geometries such as targets close to low-density regions (lung, air etc.). A clinical linear accelerator head is simulated using BEAMnrc (NRC, Canada). A novel in-house algorithm subdivides the resulting phase space into 2.5x5.0 mm 2 beamlets. Each beamlet is projected onto a patient-specific phantom. The beamlet dose contribution to each voxel in a structure-of-interest is calculated using DOSXYZnrc. The multileaf collimator (MLC) leaf positions are linked to the location of the beamlet does distributions. The MLC shapes are optimized using direct aperture optimization (DAO). A final Monte Carlo calculation with MLC modeling is used to compute the final dose distribution. Monte Carlo simulation can generate accurate beamlet dose distributions for traditionally difficult-to-calculate geometries, particularly for small fields crossing regions of tissue inhomogeneity. The introduction of DAO results in an additional improvement by increasing the treatment delivery efficiency. For the examples presented in this paper the reduction in the total number of monitor units to deliver is ∼33% compared to fluence-based optimization methods

  13. The effect of concomitant chemotherapy on parotid gland function following head and neck IMRT

    International Nuclear Information System (INIS)

    Miah, Aisha B.; Gulliford, Sarah L.; Bhide, Shreerang A.; Zaidi, Shane H.; Newbold, Kate L.; Harrington, Kevin J.; Nutting, Christopher M.

    2013-01-01

    Purpose: To determine whether concomitant chemotherapy increases the incidence of high grade xerostomia following parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with locally advanced head and neck squamous cell cancer. Materials and methods: The incidence of high grade (⩾G2) acute (CTCAEv3.0) and late (LENTSOMA and RTOG) xerostomia was compared between patients treated with either IMRT or concomitant chemo-IMRT (c-IMRT) in 2 prospective studies. Parotid gland mean tolerance doses (D 50 ) were reported using non-linear logistic regression analysis. Results: Thirty-six patients received IMRT alone and 60 patients received c-IMRT. Patients received 65 Gy in 30 daily fractions to the primary site and involved nodal groups and 54 Gy in 30 fractions to elective nodal groups, mean doses to the parotid glands were comparable. Concomitant cisplatin 100 mg/m 2 was administered on days 1 and 29 of IMRT. The incidence of ⩾G2 subjective xerostomia was similar in both groups; acute-64.7% (IMRT) versus 60.3% (c-IMRT), p = 0.83; late-43% (IMRT) versus 34% (c-IMRT), p = 0.51. Recovery of parotid salivary flow at 1 year was higher with IMRT (64% vs 50%), but not statistically significant (p = 0.15). D 50 for absence of parotid saliva flow at 1 year was 23.2 Gy (95% CI: 17.7–28.7) for IMRT and 21.1 Gy (11.8–30.3) for c-IMRT. Conclusion: Concomitant c-IMRT does not increase the incidence of acute or late xerostomia relative to IMRT alone

  14. The effect of concomitant chemotherapy on parotid gland function following head and neck IMRT.

    Science.gov (United States)

    Miah, Aisha B; Gulliford, Sarah L; Bhide, Shreerang A; Zaidi, Shane H; Newbold, Kate L; Harrington, Kevin J; Nutting, Christopher M

    2013-03-01

    To determine whether concomitant chemotherapy increases the incidence of high grade xerostomia following parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with locally advanced head and neck squamous cell cancer. The incidence of high grade (≥G2) acute (CTCAEv3.0) and late (LENTSOMA and RTOG) xerostomia was compared between patients treated with either IMRT or concomitant chemo-IMRT (c-IMRT) in 2 prospective studies. Parotid gland mean tolerance doses (D₅₀) were reported using non-linear logistic regression analysis. Thirty-six patients received IMRT alone and 60 patients received c-IMRT. Patients received 65 Gy in 30 daily fractions to the primary site and involved nodal groups and 54 Gy in 30 fractions to elective nodal groups, mean doses to the parotid glands were comparable. Concomitant cisplatin 100mg/m(2) was administered on days 1 and 29 of IMRT. The incidence of ≥G2 subjective xerostomia was similar in both groups; acute-64.7% (IMRT) versus 60.3% (c-IMRT), p=0.83; late-43% (IMRT) versus 34% (c-IMRT), p=0.51. Recovery of parotid salivary flow at 1 year was higher with IMRT (64% vs 50%), but not statistically significant (p=0.15). D₅₀ for absence of parotid saliva flow at 1 year was 23.2 Gy (95% CI: 17.7-28.7) for IMRT and 21.1 Gy (11.8-30.3) for c-IMRT. Concomitant c-IMRT does not increase the incidence of acute or late xerostomia relative to IMRT alone. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linac - testing IMRT to the limit?

    International Nuclear Information System (INIS)

    Webb, S.

    1999-01-01

    In this paper it is proposed that intensity-modulated radiotherapy (IMRT) could be delivered optimally by a short-length linac mounted on a robotic arm. The robot would allow the linac to 'plant' narrow pencils of photon radiation with any orientation (excluding zones within which the linac and couch might collide) relative to the planning target volume (PTV). The treatment is specified by the trajectory of the robot and by the number of monitor units (MUs) delivered at each robotic orientation. An inverse-planning method to determine the optimum robotic trajectory is presented. It is shown that for complex PTVs, specifically those with concavities in their outline, the conformality of the treatment is improved by the use of a complex trajectory in comparison with a less complex constrained trajectory and this improvement is quantified. It is concluded that robotic linac delivery would lead to a great flexibility in those IMRT treatments requiring very complicated dose distributions with complex 3D shapes. However, even using very fast computers, the goal of determining whether robotic linac delivery is the ultimate IMRT cannot be conclusively reached at present. (author)

  16. General strategy for the protection of organs at risk in IMRT therapy of a moving body

    International Nuclear Information System (INIS)

    Abolfath, Ramin M.; Papiez, Lech

    2009-01-01

    We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dose delivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control of radiation delivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dose delivered to OAR in cases where organs at risk move relative to a treatment target.

  17. General strategy for the protection of organs at risk in IMRT therapy of a moving body

    Energy Technology Data Exchange (ETDEWEB)

    Abolfath, Ramin M.; Papiez, Lech [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas 75390 (United States)

    2009-07-15

    We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dose delivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control of radiation delivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dose delivered to OAR in cases where organs at risk move relative to a treatment target.

  18. Prospective evaluation of delayed central nervous system (CNS) toxicity of hyperfractionated total body irradiation (TBI)

    International Nuclear Information System (INIS)

    Wenz, Frederik; Steinvorth, Sarah; Lohr, Frank; Fruehauf, Stefan; Wildermuth, Susanne; Kampen, Michael van; Wannenmacher, Michael

    2000-01-01

    Purpose: Prospective evaluation of chronic radiation effects on the healthy adult brain using neuropsychological testing of intelligence, attention, and memory. Methods and Materials: 58 patients (43 ± 10 yr) undergoing hyperfractionated total body irradiation (TBI) (TBI, 14.4 Gy, 12 x 1.2 Gy in 4 days) before bone marrow or peripheral blood stem cell transplantation were prospectively included. Twenty-one recurrence-free long-term survivors were re-examined 6-36 months (median 27 months) after completion of TBI. Neuropsychological testing included assessment of general intelligence, attention, and memory using normative, standardized psychometric tests. Mood status was controlled, as well. Test results are given as IQ scores (population mean 100) or percentiles for attention and memory (population mean 50). Results: The 21 patients showed normal baseline test results of IQ (101 ± 13) and attention (53 ± 28), with memory test scores below average (35 ± 21). Test results of IQ (98 ± 17), attention (58 ± 27), and memory (43 ± 28) showed no signs of clinically measurable radiation damage to higher CNS (central nervous system) functions during the follow-up. The mood status was improved. Conclusion: The investigation of CNS toxicity after hyperfractionated TBI showed no deterioration of test results in adult recurrence-free patients with tumor-free CNS. The median follow-up of 27 months will be extended.

  19. Intensity modulated radiotherapy (IMRT) in bilateral retinoblastoma

    International Nuclear Information System (INIS)

    Atalar, Banu; Ozyar, Enis; Gunduz, Kaan; Gungor, Gorkem

    2010-01-01

    External beam radiotherapy (EBRT) for retinoblastoma has traditionally been done with conventional radiotherapy techniques which resulted high doses to the surrounding normal tissues. A 20 month-old girl with group D bilateral retinoblastoma underwent intensity modulated radiotherapy (IMRT) to both eyes after failing chemoreduction and focal therapies including cryotherapy and transpupillary thermotherapy. In this report, we discuss the use of IMRT as a method for reducing doses to adjacent normal tissues while delivering therapeutic doses to the tumour tissues compared with 3-dimensional conformal radiotherapy (3DCRT). At one year follow-up, the patient remained free of any obvious radiation complications. Image guided IMRT provides better dose distribution than 3DCRT in retinoblastoma eyes, delivering the therapeutic dose to the tumours and minimizing adjacent tissue damage

  20. Hyperfractionated 3D conformal radiotherapy and concurrent chemotherapy for unresectable stage III non-small cell lung cancer

    International Nuclear Information System (INIS)

    Choi, E.K.; Ahn, S.D.; Yi, B.Y.; Chang, H.S.; Lee, J.H.; Suh, C.W.; Lee, J.S.; Kim, S.H.; Koh, Y.S.; Kim, W.S.; Kim, D.S.; Kim, W.D.; Sohn, K.H.

    1997-01-01

    Purpose/Objective: This phase II study has been conducted to determine the feasibility, toxicity, response rate, local control, distant metastasis, and survival of hyperfractionated 3D conformal radiotherapy and concurrent chemotherapy with mitomycin C, vinblastine, and cisplatin in unresectable stage III non-small cell lung cancer (NSCLC), and also to find the most ideal 3D conformal radiotherapy technique. Materials and Methods: From Aug 1993, 173 patients with unresectable stage III NSCLC were entered into this trial and 146 (84%) completed the treatment. Hyperfractionated radiotherapy was given to a total dose of 65-70 Gy (120 cGy/fx, bid) with concurrent 2 cycles of MVP chemotherapy (Mitomycin C 6 mg/m 2 d2 and d29, Vinblastine 6 mg/m 2 d2 and d29, Cisplatin 60 mg/m 2 d1 and d28). Of these 146 patients who completed the treatment, 78 received noncoplanar 3D conformal radiotherapy using 4-6 fields and 17 received coplanar segmented conformal radiotherapy. Clinical tumor response was assessed one month after the completion of radiotherapy by computerized tomography (CT) scan. Toxicity was graded by RTOG and SWOG criteria. Normal tissue complication probability (NTCP) for lung was calculated to find the correlation with radiation pneumonitis. Results: Nineteen (13%) had stage IIIa and 127 (87%) had IIIb disease including 16 with pleural effusion and 20 with supraclavicular lymph node metastases. Response rate was 74%, including 20% complete response and 54% partial response. With a minimum follow up of 12 months, overall survival was 60% at 1 year, 30% at 2 years and median survival was 15 months. Patients achieving a complete response (n=29) had a 2-year overall survival of 46.5% compared to 28.7% for partial responders (n=79) (p=.001). Actuarial local control was 66.7% at 1 year and 43.7% at 2 years. Actuarial distant free survival was 52.3% at 1 year and 39.8% at 2 years. Major hematologic toxicity (Gr 3-4) occurred in 33% of the patients but treatment delay

  1. IMRT for adjuvant radiation in gastric cancer: A preferred plan?

    International Nuclear Information System (INIS)

    Ringash, Jolie; Perkins, Greg; Brierley, James; Lockwood, Gina; Islam, Mohammad; Catton, Pamela; Cummings, Bernard; Kim, John; Wong, Rebecca; Dawson, Laura

    2005-01-01

    Purpose: To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over conformal planning for postoperative adjuvant radiotherapy in patients with gastric carcinoma. Methods and Materials: Twenty patients who had undergone treatment planning with conformal beam arrangements for 4500 cGy adjuvant radiotherapy between 2000 and 2001 underwent repeat planning using IMRT techniques. Conformal five-field plans were compared with seven- to nine-field coplanar sliding-window IMRT plans. For each patient, the cumulative dose-volume histograms and organ-dose summaries (without distributions or digitally reconstructed radiographs) were provided to two independent, 'blinded' GI radiation oncologists. The oncologists indicated which plan provided better planning target volume coverage and critical organ sparing, any safety concerns with either plan, and which plan they would choose to treat the patient. Results: In 18 (90%) of 20 cases, both oncologists chose the same plan. Cases with disagreement were given to a third 'blinded' reviewer. A 'preferred plan' could be determined in 19 (95%) of 20 cases. IMRT was preferred in 17 (89%) of 19 cases. In 4 (20%) of 20 IMRT plans at least one radiation oncologist had safety concerns because of the spinal cord dose (3 cases) or small bowel dose (2 cases). Of 42 ratings, IMRT was thought to provide better planning target volume coverage in 36 (86%) and better sparing of the spinal cord in 31 (74%) of 42, kidneys in 29 (69%), liver in 30 (71%), and heart in 29 (69%) of 42 ratings. The median underdose volume (1.7 vs. 4.1 cm 3 ), maximal dose to the spinal cord (36.85 vs. 45.65 Gy), and dose to 50% of the liver (17.29 vs. 27.97), heart (12.89 vs. 15.50 Gy), and left kidney (15.50 vs. 16.06 Gy) were lower with IMRT than with the conformal plans. Conclusion: Compared with the conformal plans, oncologists frequently preferred IMRT plans when using dose-volume histogram data. The advantages of IMRT plans include both

  2. Emphasizing Conformal Avoidance Versus Target Definition for IMRT Planning in Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Harari, Paul M.; Song Shiyu; Tome, Wolfgang A.

    2010-01-01

    Purpose: To describe a method for streamlining the process of elective nodal volume definition for head-and-neck (H and N) intensity-modulated radiotherapy (IMRT) planning. Methods and Materials: A total of 20 patients who had undergone curative-intent RT for H and N cancer underwent comprehensive treatment planning using three distinct, plan design techniques: conventional three-field design, target-defined IMRT (TD-IMRT), and conformal avoidance IMRT (CA-IMRT). For each patient, the conventional three-field design was created first, thereby providing the 'outermost boundaries' for subsequent IMRT design. In brief, TD-IMRT involved physician contouring of the gross tumor volume, high- and low-risk clinical target volume, and normal tissue avoidance structures on consecutive 1.25-mm computed tomography images. CA-IMRT involved physician contouring of the gross tumor volume and normal tissue avoidance structures only. The overall physician time for each approach was monitored, and the resultant plans were rigorously compared. Results: The average physician working time for the design of the respective H and N treatment contours was 0.3 hour for the conventional three-field design plan, 2.7 hours for TD-IMRT, and 0.9 hour for CA-IMRT. Dosimetric analysis confirmed that the largest volume of tissue treated to an intermediate (50 Gy) and high (70 Gy) dose occurred with the conventional three-field design followed by CA-IMRT and then TD-IMRT. However, for the two IMRT approaches, comparable results were found in terms of salivary gland and spinal cord protection. Conclusion: CA-IMRT for H and N treatment offers an alternative to TD-IMRT. The overall time for physician contouring was substantially reduced (approximately threefold), yielding a more standardized elective nodal volume. Because of the complexity of H and N IMRT target design, CA-IMRT might ultimately prove a safer and more reliable method to export to general radiation oncology practitioners, particularly

  3. Inverse IMRT workflow process at Austin health

    International Nuclear Information System (INIS)

    Rykers, K.; Fernando, W.; Grace, M.; Liu, G.; Rolfo, A.; Viotto, A.; Mantle, C.; Lawlor, M.; Au-Yeung, D.; Quong, G.; Feigen, M.; Lim-Joon, D.; Wada, M.

    2004-01-01

    Full text: The work presented here will review the strategies adopted at Austin Health to bring IMRT into clinical use. IMRT is delivered using step and shoot mode on an Elekta Precise machine with 40 pairs of 1cm wide MLC leaves. Planning is done using CMS Focus/XiO. A collaborative approach for RO's, Physicists and RTs from concept to implementation was adopted. An overview will be given of the workflow for the clinic, the equipment used, tolerance levels and the lessons learned. 1. Strategic Planning for IMRT 2. Training a. MSKCC (New York) b.ESTRO (Amsterdam) c.Elekta (US and UK) 3. Linac testing and data acquisition a. Equipment and software review and selection b. Linac reliability/geometric and mechanical checks c. Draft Patient QA procedure d. EPI Image matching checks and procedures 4. Planning system checks a. export of dose matrix (options) b. dose calculation choices 5. IMRT Research Initiatives a. IMRT Planning Studies, Stabilisation, On-line Imaging 6. Equipment Procurement and testing a. Physics and Linac Equipment, Hardware, Software/Licences, Stabilisation 7. Establishing a DICOM Environment a. Prescription sending, Image transfer for EPI checks b. QA Files 8. Physics QA (Pre-Treatment) a.Clinical plan review; DVH checks b. geometry; dosimetry checks; DICOM checks c. 2D Distance to agreement; mm difference reports; Gamma function index 9. Documentation a.Protocol Development i. ICRU 50/62 reporting and prescribing b. QA for Physics c. QA for RT's d. Generation of a report for RO/patient history. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  4. Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: Does IMRT increase the integral dose to normal brain?

    International Nuclear Information System (INIS)

    Hermanto, Ulrich; Frija, Erik K.; Lii, MingFwu J.; Chang, Eric L.; Mahajan, Anita; Woo, Shiao Y.

    2007-01-01

    Purpose: To determine whether intensity-modulated radiotherapy (IMRT) treatment increases the total integral dose of nontarget tissue relative to the conventional three-dimensional conformal radiotherapy (3D-CRT) technique for high-grade gliomas. Methods and Materials: Twenty patients treated with 3D-CRT for glioblastoma multiforme were selected for a comparative dosimetric evaluation with IMRT. Original target volumes, organs at risk (OAR), and dose-volume constraints were used for replanning with IMRT. Predicted isodose distributions, cumulative dose-volume histograms of target volumes and OAR, normal tissue integral dose, target coverage, dose conformity, and normal tissue sparing with 3D-CRT and IMRT planning were compared. Statistical analyses were performed to determine differences. Results: In all 20 patients, IMRT maintained equivalent target coverage, improved target conformity (conformity index [CI] 95% 1.52 vs. 1.38, p mean by 19.8% and D max by 10.7%), optic chiasm (D mean by 25.3% and D max by 22.6%), right optic nerve (D mean by 37.3% and D max by 28.5%), and left optic nerve (D mean by 40.6% and D max by 36.7%), p ≤ 0.01. This was achieved without increasing the total nontarget integral dose by greater than 0.5%. Overall, total integral dose was reduced by 7-10% with IMRT, p < 0.001, without significantly increasing the 0.5-5 Gy low-dose volume. Conclusions: These results indicate that IMRT treatment for high-grade gliomas allows for improved target conformity, better critical tissue sparing, and importantly does so without increasing integral dose and the volume of normal tissue exposed to low doses of radiation

  5. IMRT in hypopharyngeal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Studer, G.; Luetolf, U.M.; Davis, J.B.; Glanzmann, C. [Dept. of Radiation Oncology, Univ. Hospital, Zurich (Switzerland)

    2006-06-15

    Background and purpose: intensity-modulated radiation therapy (IMRT) data on hypopharyngeal cancer (HC) are scant. In this study, the authors report on early results in an own HC patient cohort treated with IMRT. A more favorable outcome as compared to historical data on conventional radiation techniques was expected. Patients and methods: 29 consecutive HC patients were treated with simultaneous integrated boost (SIB) IMRT between 01/2002 and 07/2005 (mean follow-up 16 months, range 4-44 months). Doses of 60-71 Gy with 2.0-2.2 Gy/fraction were applied. 26/29 patients were definitively irradiated, 86% received simultaneous cisplatin-based chemotherapy. 60% presented with locally advanced disease (T3/4 Nx, Tx N2c/3). Mean primary tumor volume measured 36.2 cm{sup 3} (4-170 cm{sup 3}), mean nodal volume 16.6 cm{sup 3} (0-97 cm{sup 3}). Results: 2-year actuarial local, nodal, distant control, and overall disease-free survival were 90%, 93%, 93%, and 90%, respectively. In 2/4 patients with persistent disease (nodal in one, primary in three), salvage surgery was performed. The mean dose to the spinal cord (extension of > 5-15 mm) was 26 Gy (12-38 Gy); the mean maximum (point) dose was 44.4 Gy (26-58.9 Gy). One grade (G) 3 dysphagia and two G4 reactions (laryngeal fibrosis, dysphagia), both following the schedule with 2.2 Gy per fraction, have been observed so far. Larynx preservation was achieved in 25/26 of the definitively irradiated patients (one underwent a salvage laryngectomy); 23 had no or minimal dysphagia (G0-1). Conclusion: excellent early disease control and high patient satisfaction with swallowing function in HC following SIB IMRT were observed; these results need to be confirmed based on a longer follow-up period. In order to avoid G4 reactions, SIB doses of < 2.2 Gy/fraction are recommended for large tumors involving laryngeal structures. (orig.)

  6. Parotid-sparing intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma: Preserved parotid function after IMRT on quantitative salivary scintigraphy, and comparison with historical data after conventional radiotherapy

    International Nuclear Information System (INIS)

    Hsiung, C.-Y.; Ting, H.-M.; Huang, H.-Y.; Lee, C.-H.; Huang, E.-Y.; Hsu, H.-C.

    2006-01-01

    Purpose: To evaluate the parotid function after parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with nasopharyngeal carcinoma (NPC). Methods and Materials: From March 2003 to May 2004, 16 patients with nonmetastatic NPC underwent parotid-sparing IMRT. Eight of these patients had Stage III or IV NPC based on the 1997 American Joint Committee on Cancer staging system. The post-IMRT parotid function was evaluated by quantitative salivary scintigraphy and represented by the maximal excretion ratio (MER) of the parotid gland after sialogogue stimulation. The parotid function of 16 NPC patients who were previously treated with conventional radiotherapy was reviewed as the historical control. Results: In the parotid-sparing IMRT group, all 16 patients were alive and without cancer at the end of follow-up period (median, 24.2 months). The mean parotid MER was 53.5% before radiotherapy, 10.7% at 1 month post-IMRT, and 23.3% at 9 months post-IMRT. In the conventional radiotherapy group, the mean parotid MER was 0.6% at 6 to 12 months postradiotherapy. The difference was statistically significant (23.3% vs. 0.6%, p < 0.001, Mann-Whitney test). In the IMRT group, the mean parotid doses ranged from 33.2 Gy to 58.8 Gy (average, 43.9 Gy). The correlation between the mean parotid dose and the percentage decrease of parotid MER at 9 months post-IMRT (dMER) was statically significant (p = 0.008, Pearson correlation). Conclusions: Although the mean parotid doses are relatively high, the significant preservation of parotid function is achieved with IMRT for NPC patients. The significant correlation between mean parotid dose and parotid dMER demonstrates the dose-function relationship of the parotid gland

  7. A leaf sequencing algorithm to enlarge treatment field length in IMRT

    International Nuclear Information System (INIS)

    Xia Ping; Hwang, Andrew B.; Verhey, Lynn J.

    2002-01-01

    patterns. Using a single isocenter, the new algorithm provides a solution to extend the usable IMRT field length from 21 to 27 cm for IMRT on a commercial linear accelerator using the step and shoot delivery method

  8. Time-dose modifications

    International Nuclear Information System (INIS)

    Kian Ang, K.

    1987-01-01

    Changes in fractionation schedule can be made by various approaches. However, from the first principle, it is anticipated that strategies of hyperfractionation and/or accelerated fractionation offer the most promised in improving the therapeutic ratio. Hyperfractionation is defined as a treatment schedule in which a large number of significantly reduced dose fractions (--1.2 Gy/fraction) is used to give a greater total dose in a conventional overall time period. The results of the pilot studies testing the efficacy of hyperfractionation have been encouraging. The most valid clinical trial of pure hyperfractionation, however, is that conducted by the EORTC. This study compared 70 Gy in 35 fractions or 80.5 Gy in 70 fractions over 7 weeks in the treatment of patients with oropharyngeal carcinomas. The local tumor control was significantly improved in the hyperfractionated arm without increasing the morbidity. Accelerated fractionation is defined as a schedule in which the overall time of treatment is reduced without significant changes in the total dose and fraction size. The strategy has been used to treat patients with malignant gliomas, melanomas and Head and Neck cancers. The data in Head and Neck Cancers seem to be promising

  9. MO-D-213-05: Sensitivity of Routine IMRT QA Metrics to Couch and Collimator Rotations

    International Nuclear Information System (INIS)

    Alaei, P

    2015-01-01

    Purpose: To assess the sensitivity of gamma index and other IMRT QA metrics to couch and collimator rotations. Methods: Two brain IMRT plans with couch and/or collimator rotations in one or more of the fields were evaluated using the IBA MatriXX ion chamber array and its associated software (OmniPro-I’mRT). The plans were subjected to routine QA by 1) Creating a composite planar dose in the treatment planning system (TPS) with the couch/collimator rotations and 2) Creating the planar dose after “zeroing” the rotations. Plan deliveries to MatriXX were performed with all rotations set to zero on a Varian 21ex linear accelerator. This in effect created TPS-created planar doses with an induced rotation error. Point dose measurements for the delivered plans were also performed in a solid water phantom. Results: The IMRT QA of the plans with couch and collimator rotations showed clear discrepancies in the planar dose and 2D dose profile overlays. The gamma analysis, however, did pass with the criteria of 3%/3mm (for 95% of the points), albeit with a lower percentage pass rate, when one or two of the fields had a rotation. Similar results were obtained with tighter criteria of 2%/2mm. Other QA metrics such as percentage difference or distance-to-agreement (DTA) histograms produced similar results. The point dose measurements did not obviously indicate the error due to location of dose measurement (on the central axis) and the size of the ion chamber used (0.6 cc). Conclusion: Relying on Gamma analysis, percentage difference, or DTA to determine the passing of an IMRT QA may miss critical errors in the plan delivery due to couch/collimator rotations. A combination of analyses for composite QA plans, or per-beam analysis, would detect these errors

  10. Fast, daily linac verification for segmented IMRT using electronic portal imaging

    International Nuclear Information System (INIS)

    Vieira, Sandra C.; Bolt, Rene A.; Dirkx, Maarten L.P.; Visser, Andries G.; Heijmen, Ben J.M.

    2006-01-01

    Purpose: Intensity modulated radiotherapy (IMRT) requires dedicated quality assurance (QA). Recently, we have published a method for fast (1-2 min) and accurate linac quality control for dynamic multileaf collimation, using a portal imaging device. This method is in routine use for daily leaf motion verification. The purpose of the present study was to develop an equivalent procedure for QA of IMRT with segmented (static) multileaf collimation (SMLC). Materials and methods: The QA procedure is based on measurements performed during 3- to 8-month periods at Elekta, Siemens and Varian accelerators. On each measurement day, images were acquired for a field consisting of five 3 x 22 cm 2 segments. These 10 monitor unit (MU) segments were delivered in SMLC mode, moving the leaves from left to right. Deviations of realized leaf gap widths from the prescribed width were analysed to study the leaf positioning accuracy. To assess hysteresis in leaf positioning, the sequential delivery of the SMLC segments was also inverted. A static 20 x 20 cm 2 field was delivered with exposures between 1 and 50 MU to study the beam output and beam profile at low exposures. Comparisons with an ionisation chamber were made to verify the EPID dose measurements at low MU. Dedicated software was developed to improve the signal-to-noise ratio and to correct for image distortion. Results and conclusions: The observed long-term leaf gap reproducibility (1 standard deviation) was 0.1 mm for the Varian, and 0.2 mm for the Siemens and the Elekta accelerators. In all cases the hysteresis was negligible. Down to the lowest MU, beam output measurements performed with the EPID agreed within 1 ± 1% (1SD) with ionisation chamber measurements. These findings led to a fast (3-4 min) procedure for accurate, daily linac quality control for SMLC

  11. A planning and delivery study of a rotational IMRT technique with burst delivery

    International Nuclear Information System (INIS)

    Kainz, Kristofer; Chen, Guang-Pei; Chang, Yu-Wen; Prah, Douglas; Sharon Qi, X.; Shukla, Himanshu P.; Stahl, Johannes; Allen Li, X.

    2011-01-01

    Purpose: A novel rotational IMRT (rIMRT) technique using burst delivery (continuous gantry rotation with beam off during MLC repositioning) is investigated. The authors evaluate the plan quality and delivery efficiency and accuracy of this dynamic technique with a conventional flat 6 MV photon beam. Methods: Burst-delivery rIMRT was implemented in a planning system and delivered with a 160-MLC linac. Ten rIMRT plans were generated for five anonymized patient cases encompassing head and neck, brain, prostate, and prone breast. All plans were analyzed retrospectively and not used for treatment. Among the varied plan parameters were the number of optimization points, number of arcs, gantry speed, and gantry angle range (alpha) over which the beam is turned on at each optimization point. Combined rotational/step-and-shoot rIMRT plans were also created by superimposing multiple-segment static fields at several optimization points. The rIMRT trial plans were compared with each other and with plans generated using helical tomotherapy and VMAT. Burst-mode rotational IMRT plans were delivered and verified using a diode array, ionization chambers, thermoluminescent dosimeters, and film. Results: Burst-mode rIMRT can achieve plan quality comparable to helical tomotherapy, while the former may lead to slightly better OAR sparing for certain cases and the latter generally achieves slightly lower hot spots. Few instances were found in which increasing the number of optimization points above 36, or superimposing step-and-shoot IMRT segments, led to statistically significant improvements in OAR sparing. Using an additional rIMRT partial arc yielded substantial OAR dose improvements for the brain case. Measured doses from the rIMRT plan delivery were within 4% of the plan calculation in low dose gradient regions. Delivery time range was 228-375 s for single-arc rIMRT 200-cGy prescription with a 300 MU/min dose rate, comparable to tomotherapy and VMAT. Conclusions: Rotational IMRT

  12. Peripheral doses of cranial pediatric IMRT performed with attenuator blocks; Doses perifericas de IMRT cranial pediatrica realizada com blocos atenuadores

    Energy Technology Data Exchange (ETDEWEB)

    Soboll, Danyel Scheidegger; Schitz, Ivette; Schelin, Hugo Reuters, E-mail: soboll@utfpr.edu.b, E-mail: iveteschitz@yahoo.com.b, E-mail: schelin@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Silva, Ricardo Goulart da, E-mail: ricardo.goulart@ymail.co [Hospital Angelina Caron, Campina Grande do Sul, PR (Brazil); Viamonte, Alfredo, E-mail: aviamonte@inca.gov.b [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    This paper presents values of peripheral doses measured at six vital points of simulator objects which represent the ages of 2, 5 and 10 years old, submitted to a cranial IMRT procedure that applied compensator blocks interposed to 6 MV beams. The found values indicate that there is independence of dose with position of measurements and age of the patient, as the peripheral dose at the points nearest and the 2 year old simulator object where larger. The doses in thyroid reached the range of 1.4 to 2.9% of the dose prescribed in the isocenter, indicating that the peripheral doses for IMRT that employ compensator blocks can be greater than for the IMRT produced with sliding window technique

  13. SU-E-T-16: A Hybrid VMAT/IMRT Technique for the Treatment of Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Zhao, N; Yang, R; Wang, J

    2014-01-01

    Purpose: To investigate a Hybrid VMAT/IMRT technique which combines volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). Methods: 2 full arcs VMAT, 9-field IMRT and Hybrid VMAT/IMRT plans were created for 10 patients with NPC. The Hybrid VMAT/IMRT technique consisted of 1 full VMAT arc and 7 IMRT fields. The dose distribution of planning target volume (PTV) and organs at risk (OARs) for Hybrid VMAT/IMRT was compared with IMRT and VMAT. The monitor units (MUs) were also evaluated. Results: The Hybrid VMAT/IMRT technique significantly improved target dose homogeneity compared with IMRT and VMAT for PTV70 and PTV54. For PTV70 and PTV60, the Hybrid VMAT/IMRT technique significantly improved target dose conformity compared with IMRT (0.62 vs 0.47; p<0.05 and 0.64 vs 0.58; p<0.05, respectively) and VMAT (0.62 vs 0.43; p<0.05 and 0.64 vs 0.6; p<0.05, respectively). The near maximum dose (D2%) of temporomandibular joint (TMJ), temporal lobe and mandible for Hybrid plans were 5.5%, 7.9% and 5.2% lower than IMRT plans (p<0.05). The mean dose of TMJ, temporal lobe, mandible and unspecified tissue for Hybrid plans were 12.8%, 11.4%, 4.2% and 4.1% lower than IMRT plans (p<0.05). The mean dose of right parotid, mandible and unspecified tissue for Hybrid plans were 3.3%, 2.4% and 3.1% lower than VMAT plans (p<0.05). The mean MUs needed for IMRT, VMAT and Hybrid plans were 2256, 507 and 1394, respectively. Conclusion: Hybrid VMAT/IMRT technique significantly improved the target dose homogeneity and conformity compared with IMRT and VMAT and reduced the dose of OARs and unspecified tissue compared with IMRT with fewer MUs. Compared with VMAT, Hybrid VMAT/IMRT technique can better protect parotid gland, mandible and unspecified tissue. Ruijie Yang was funded by the grant project: National Natural Science Foundation of China (No. 81071237). Other authors have no competing interest for this work

  14. SU-E-T-16: A Hybrid VMAT/IMRT Technique for the Treatment of Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, N; Yang, R; Wang, J [Peking University Third Hospital, Beijing, Beijing (China)

    2014-06-01

    Purpose: To investigate a Hybrid VMAT/IMRT technique which combines volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). Methods: 2 full arcs VMAT, 9-field IMRT and Hybrid VMAT/IMRT plans were created for 10 patients with NPC. The Hybrid VMAT/IMRT technique consisted of 1 full VMAT arc and 7 IMRT fields. The dose distribution of planning target volume (PTV) and organs at risk (OARs) for Hybrid VMAT/IMRT was compared with IMRT and VMAT. The monitor units (MUs) were also evaluated. Results: The Hybrid VMAT/IMRT technique significantly improved target dose homogeneity compared with IMRT and VMAT for PTV70 and PTV54. For PTV70 and PTV60, the Hybrid VMAT/IMRT technique significantly improved target dose conformity compared with IMRT (0.62 vs 0.47; p<0.05 and 0.64 vs 0.58; p<0.05, respectively) and VMAT (0.62 vs 0.43; p<0.05 and 0.64 vs 0.6; p<0.05, respectively). The near maximum dose (D2%) of temporomandibular joint (TMJ), temporal lobe and mandible for Hybrid plans were 5.5%, 7.9% and 5.2% lower than IMRT plans (p<0.05). The mean dose of TMJ, temporal lobe, mandible and unspecified tissue for Hybrid plans were 12.8%, 11.4%, 4.2% and 4.1% lower than IMRT plans (p<0.05). The mean dose of right parotid, mandible and unspecified tissue for Hybrid plans were 3.3%, 2.4% and 3.1% lower than VMAT plans (p<0.05). The mean MUs needed for IMRT, VMAT and Hybrid plans were 2256, 507 and 1394, respectively. Conclusion: Hybrid VMAT/IMRT technique significantly improved the target dose homogeneity and conformity compared with IMRT and VMAT and reduced the dose of OARs and unspecified tissue compared with IMRT with fewer MUs. Compared with VMAT, Hybrid VMAT/IMRT technique can better protect parotid gland, mandible and unspecified tissue. Ruijie Yang was funded by the grant project: National Natural Science Foundation of China (No. 81071237). Other authors have no competing interest for this work.

  15. Genital marginal failures after intensity-modulated radiation therapy (IMRT) in squamous cell anal cancer: no higher risk with IMRT when compared to 3DCRT.

    Science.gov (United States)

    Dell'Acqua, V; Kobiela, J; Kraja, F; Leonardi, M C; Surgo, A; Zerella, M A; Arculeo, S; Fodor, C; Ricotti, R; Zampino, M G; Ravenda, S; Spinoglio, G; Biffi, R; Bazani, A; Luraschi, R; Vigorito, S; Spychalski, P; Orecchia, R; Glynne-Jones, R; Jereczek-Fossa, B A

    2018-03-28

    Intensity-modulated radiotherapy (IMRT) is considered the preferred option in squamous cell canal cancer (SCAC), delivering high doses to tumor volumes while minimizing dose to surrounding normal tissues. IMRT has steep dose gradients, but the technique is more demanding as deep understanding of target structures is required. To evaluate genital marginal failure in a cohort of patients with non-metastatic SCAC treated either with IMRT or 3DCRT and concurrent chemotherapy, 117 patients with SCAC were evaluated: 64 and 53 patients were treated with IMRT and 3DCRT techniques, respectively. All patients underwent clinical and radiological examination during their follow-up. Tumor response was evaluated with response evaluation criteria in solid tumors v1.1 guideline on regular basis. All patients' data were analyzed, and patients with marginal failure were identified. Concomitant chemotherapy was administered in 97 and 77.4% of patients in the IMRT and 3DCRT groups, respectively. In the IMRT group, the median follow-up was 25 months (range 6-78). Progressive disease was registered in 15.6% of patients; infield recurrence, distant recurrence and both infield recurrence and distant recurrence were identified in 5, 4 and 1 patient, respectively. Two out of 64 patients (3.1%) had marginal failures, localized at vagina/recto-vaginal septum and left perineal region. In the 3DCRT group, the median follow-up was 71.3 months (range 6-194 months). Two out of 53 patients (3.8%) had marginal failures, localized at recto-vaginal septum and perigenital structures. The rate of marginal failures was comparable in IMRT and 3DCRT groups (χ 2 test p = 0.85). In this series, the use of IMRT for the treatment of SCAC did not increase the rate of marginal failures offering improved dose conformity to the target. Dose constraints should be applied with caution-particularly in females with involvement of the vagina or the vaginal septum.

  16. Overview of IMRT - definitions and basic concepts

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2008-01-01

    A detailed advanced outline of the title topic is presented. Summary is formulated as follows: (i) Conventional MLC, developed for block replacement, require corrections and careful QA when when used for IMRT; (ii) There are both advantages and disadvantages of static or dynamic MLC delivery; (iii) Tomotherapy uses binary MLC systems specifically designed for IMRT; (iv) There are two types of optimization, grid of beamlets and direct aperture methods; (v) Optimization is controlled by objective functions. (P.A.)

  17. Comparison of film dosimetry and Monte Carlo simulations in small field IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.R.; Suh, T.S.; Choe, B.Y.; Lee, H.K. [The Catholic Univ., Seoul (Korea, Republic of); Sohn. Jason W. [Washington Univ., St. Louis (United States)

    2002-07-01

    Intensity modulated radiation therapy(IMRT) is a recent useful technique that conforms a high dose to the target volume while restricting dose to the surrounding critical organs. In IMRT, the small size beam let is used for intensity modulation. Thus, dose calculation in small field is very important. But, dose calculation in small field is not accurate in recent RTP system because electronic disequilibrium and the effect of multiple scattering electron are not considered in dose calculation. and therefore, We have evaluated the errors of depth dose and beam profile between measurement data and Monte Carlo simulation. With a homogeneous phantom and two heterogeneous phantoms, A thermoluminescent dosimeter (TLD) and radiochromic films have been selected for dose measurement in 6 MV photon beams. A linear accelerator Varian 2300C (Varian Medical Systems, USA) equipped with a multileaf collimator have been used in dose measurement. The results of simulations using the Monte Carlo systems BEAM/EGS4 (NRC, Canada) to model the beam geometry have been compared with dose measurements. Generally good agreements were found between measurements and dose calculations of Monte Carlo simulation. But some discrepancies were found in this study. Thus further study will be needed to compensate these errors.

  18. First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions

    International Nuclear Information System (INIS)

    Woodruff, Henry C.; Fuangrod, Todsaporn; Van Uytven, Eric; McCurdy, Boyd M.C.; Beek, Timothy van; Bhatia, Shashank; Greer, Peter B.

    2015-01-01

    Purpose: Gantry-mounted megavoltage electronic portal imaging devices (EPIDs) have become ubiquitous on linear accelerators. WatchDog is a novel application of EPIDs, in which the image frames acquired during treatment are used to monitor treatment delivery in real time. We report on the preliminary use of WatchDog in a prospective study of cancer patients undergoing intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) and identify the challenges of clinical adoption. Methods and Materials: At the time of submission, 28 cancer patients (head and neck, pelvis, and prostate) undergoing fractionated external beam radiation therapy (24 IMRT, 4 VMAT) had ≥1 treatment fraction verified in real time (131 fractions or 881 fields). EPID images acquired continuously during treatment were synchronized and compared with model-generated transit EPID images within a frame time (∼0.1 s). A χ comparison was performed to cumulative frames to gauge the overall delivery quality, and the resulting pass rates were reported graphically during treatment delivery. Every frame acquired (500-1500 per fraction) was saved for postprocessing and analysis. Results: The system reported the mean ± standard deviation in real time χ 91.1% ± 11.5% (83.6% ± 13.2%) for cumulative frame χ analysis with 4%, 4 mm (3%, 3 mm) criteria, global over the integrated image. Conclusions: A real-time EPID-based radiation delivery verification system for IMRT and VMAT has been demonstrated that aims to prevent major mistreatments in radiation therapy.

  19. First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, Henry C., E-mail: henry.woodruff@newcastle.edu.au [Faculty of Science and Information Technology, School of Mathematical and Physical Sciences, University of Newcastle, New South Wales (Australia); Fuangrod, Todsaporn [Faculty of Engineering and Built Environment, School of Electrical Engineering and Computer Science, University of Newcastle, New South Wales (Australia); Van Uytven, Eric; McCurdy, Boyd M.C.; Beek, Timothy van [Division of Medical Physics, CancerCare Manitoba, Winnipeg, Manitoba (Canada); Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba (Canada); Department of Radiology, University of Manitoba, Winnipeg, Manitoba (Canada); Bhatia, Shashank [Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, New South Wales (Australia); Greer, Peter B. [Faculty of Science and Information Technology, School of Mathematical and Physical Sciences, University of Newcastle, New South Wales (Australia); Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, New South Wales (Australia)

    2015-11-01

    Purpose: Gantry-mounted megavoltage electronic portal imaging devices (EPIDs) have become ubiquitous on linear accelerators. WatchDog is a novel application of EPIDs, in which the image frames acquired during treatment are used to monitor treatment delivery in real time. We report on the preliminary use of WatchDog in a prospective study of cancer patients undergoing intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) and identify the challenges of clinical adoption. Methods and Materials: At the time of submission, 28 cancer patients (head and neck, pelvis, and prostate) undergoing fractionated external beam radiation therapy (24 IMRT, 4 VMAT) had ≥1 treatment fraction verified in real time (131 fractions or 881 fields). EPID images acquired continuously during treatment were synchronized and compared with model-generated transit EPID images within a frame time (∼0.1 s). A χ comparison was performed to cumulative frames to gauge the overall delivery quality, and the resulting pass rates were reported graphically during treatment delivery. Every frame acquired (500-1500 per fraction) was saved for postprocessing and analysis. Results: The system reported the mean ± standard deviation in real time χ 91.1% ± 11.5% (83.6% ± 13.2%) for cumulative frame χ analysis with 4%, 4 mm (3%, 3 mm) criteria, global over the integrated image. Conclusions: A real-time EPID-based radiation delivery verification system for IMRT and VMAT has been demonstrated that aims to prevent major mistreatments in radiation therapy.

  20. Consequences of leaf calibration errors on IMRT delivery

    International Nuclear Information System (INIS)

    Sastre-Padro, M; Welleweerd, J; Malinen, E; Eilertsen, K; Olsen, D R; Heide, U A van der

    2007-01-01

    IMRT treatments using multi-leaf collimators may involve a large number of segments in order to spare the organs at risk. When a large proportion of these segments are small, leaf positioning errors may become relevant and have therapeutic consequences. The performance of four head and neck IMRT treatments under eight different cases of leaf positioning errors has been studied. Systematic leaf pair offset errors in the range of ±2.0 mm were introduced, thus modifying the segment sizes of the original IMRT plans. Thirty-six films were irradiated with the original and modified segments. The dose difference and the gamma index (with 2%/2 mm criteria) were used for evaluating the discrepancies between the irradiated films. The median dose differences were linearly related to the simulated leaf pair errors. In the worst case, a 2.0 mm error generated a median dose difference of 1.5%. Following the gamma analysis, two out of the 32 modified plans were not acceptable. In conclusion, small systematic leaf bank positioning errors have a measurable impact on the delivered dose and may have consequences for the therapeutic outcome of IMRT

  1. Hyperfractionated high-dose total body irradiation in bone marrow transplantation for Ph{sup 1}-positive acute lymphoblastic leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Akira; Ebihara, Yasuhiro; Mitsui, Tetsuo [Tokyo Univ. (Japan). Hospital of the Institute of Medical Science] [and others

    1998-12-01

    In two cases of Philadelphia-positive childhood acute lymphoblastic leukemia (Ph{sup 1} ALL), we performed allogeneic bone marrow transplantation (AlloBMT) with preconditioning regimen, including hyperfractionated high-dose total body irradiation (TBI) (13.5 Gy, in 9 fractions). Their disease statuses at BMT were hematological relapse in case 1 and molecular relapse in case 2. Bone marrow donors were unrelated in case 1, and HLA was a partially mismatched mother in case 2. Regimen-related toxicity was tolerable in both cases. Hematological recovery was rapid, and engraftment was obtained on day 14 in case 1 and on day 12 in case 2. BCR/ABL message in bone marrow disappeared on day 89 in case 1 and on day 19 in case 2 and throughout their subsequent clinical courses. Although short-term MTX and Cy-A continuous infusion were used for GVHD prophylaxis, grade IV GVHD was observed in case 1 and grade III in case 2. Both cases experienced hemorrhagic cystitis because of adenovirus type 11 infection. Although case 1 died of interstitial pneumonitis on day 442, case 2 has been free of disease through day 231. AlloBMT for Ph{sup 1} ALL with preconditioning regimen including hyperfractionated high-dose TBI is considered to be worth further investigation. (author)

  2. Comparison of Acute and Late Toxicity of Two Regimens of 3- and 5-Week Concomitant Boost Prone IMRT to Standard 6-Week Breast Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Raza, Shahzad; Lymberis, Stella C.; Ciervide, Raquel [Department of Radiation Oncology and Surgery, New York University School of Medicine, New York University Langone Medical Center, New York, NY (United States); Axelrod, Deborah [Department of Surgery, New York University School of Medicine, New York University Langone Medical Center, New York, NY (United States); Fenton-Kerimian, Maria; Magnolfi, Chiara; Rosenstein, Barry; DeWyngaert, J. Keith; Formenti, Silvia C., E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology and Surgery, New York University School of Medicine, New York University Langone Medical Center, New York, NY (United States)

    2012-05-08

    Purpose: Limited information is available comparing toxicity of accelerated radiotherapy (RT) to that of standard fractionation RT for early stage breast cancer. We report early and late toxicities of two prone regimens of accelerated intensity-modulated radiation therapy (IMRT) with a concomitant boost (CB) to the tumor bed delivered over 3 or 5 weeks as compared to standard 6 week RT with a sequential electron boost. Methods: From 2/2003 to 12/2007, 169 consecutive patients with Stage I–II breast cancer were offered the choice to undergo prone RT with either: a 6-week standard RT regimen of 46 Gy/23 fractions (fx) to the whole breast (WB), followed by a14 Gy sequential boost (SB) to the tumor bed (6wSB), a 5-week regimen of 50 Gy to WB with an IMRT CB of 6.25 Gy in 25 fx (5wCB); or a 3-week protocol of 40.5 Gy to WB with an IMRT CB of 7.5 Gy in 15 fx (3wCB). These regimens were estimated as biologically equivalent, based on alpha/beta = 4 for tumor control. Toxicities were reported using RTOG and LENT/SOMA scoring. Results: 51/169 patients chose standard 6wSB, 28 selected 5wCB, and 90 enrolled in 3wCB protocol. Maximum acute toxicity was Grade 3 dermatitis in 4% of the patients in the 6wSB compared 1% in 3wCB. In general, acute complications (breast pain, fatigue, and dermatitis) were significantly less in the 3wCB than in the other schedules (P < 0.05). With a median follow-up of 61 months, the only Grade 3 late toxicity was telangiectasia in two patients: one in 3wCB and one in 5wCB group. Notably, fibrosis was comparable among the three groups (P = NS). Conclusion: These preliminary data suggest that accelerated regimens of breast RT over 3 or 5 weeks in the prone position, with an IMRT tumor bed CB, result in comparable late toxicity to standard fractionation with a sequential tumor boost delivered over 6 weeks. As predicted by radiobiological modeling the shorter regimen was associated with less acute effects.

  3. A feasibility study of using conventional jaws to deliver complex IMRT plans for head and neck cancer

    International Nuclear Information System (INIS)

    Mu, G; Xia, P

    2009-01-01

    Previous studies have demonstrated that simple intensity-modulated radiotherapy (IMRT) plans can be produced with a series of rectangular segments formed by conventional jaws. This study investigates whether complex IMRT plans for head and neck cancer can be delivered with the conventional jaws efficiently. Six nasopharyngeal cancer patients, previously treated with multi-leaf collimator (MLC)-IMRT plans, were re-planned using conventional jaw delivery options. All IMRT plans were subject to the plan acceptance criteria of the RTOG-0225 protocol. For a selected patient, the maximum number of segments varied from five to nine per beam, and was tested for both jaws-only IMRT (JO-IMRT) plans and MLC-IMRT plans. Subsequently, JO-IMRT plans and MLC-IMRT on the same treatment planning system were attempted for all patients with identical beams. The dose distribution, dose volume histograms (DVH), the conformal index (COIN), the uniformity index and delivery efficiency were compared between the MLC-IMRT and JO-IMRT plans. All JO-IMRT plans met the RTOG-0225 criteria for tumor coverage and sensitive structures sparing. The corresponding MLC-IMRT and JO-IMRT plans show comparable conformality and uniformity, with average COINs of the planning gross tumor volume(pGTV) 37.7% ± 18.7% versus 37.9% ± 18.1%, and the average uniformity index 82.8% ± 2.5% versus 83.6% ± 3.1%, respectively. The average monitor unit for JO-IMRT plans was about twice that of MLC-IMRT plans. In conclusion, conventional jaws can be used solely to deliver complex IMRT plans for patients with nasopharyngeal cancer yet still within a practical delivery time.

  4. A Comprehensive Comparison of IMRT and VMAT Plan Quality for Prostate Cancer Treatment

    International Nuclear Information System (INIS)

    Quan, Enzhuo M.; Li Xiaoqiang; Li Yupeng; Wang Xiaochun; Kudchadker, Rajat J.; Johnson, Jennifer L.; Kuban, Deborah A.; Lee, Andrew K.; Zhang Xiaodong

    2012-01-01

    Purpose: We performed a comprehensive comparative study of the plan quality between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of prostate cancer. Methods and Materials: Eleven patients with prostate cancer treated at our institution were randomly selected for this study. For each patient, a VMAT plan and a series of IMRT plans using an increasing number of beams (8, 12, 16, 20, and 24 beams) were examined. All plans were generated using our in-house–developed automatic inverse planning (AIP) algorithm. An existing eight-beam clinical IMRT plan, which was used to treat the patient, was used as the reference plan. For each patient, all AIP-generated plans were optimized to achieve the same level of planning target volume (PTV) coverage as the reference plan. Plan quality was evaluated by measuring mean dose to and dose–volume statistics of the organs at risk, especially the rectum, from each type of plan. Results: For the same PTV coverage, the AIP-generated VMAT plans had significantly better plan quality in terms of rectum sparing than the eight-beam clinical and AIP-generated IMRT plans (p < 0.0001). However, the differences between the IMRT and VMAT plans in all the dosimetric indices decreased as the number of beams used in IMRT increased. IMRT plan quality was similar or superior to that of VMAT when the number of beams in IMRT was increased to a certain number, which ranged from 12 to 24 for the set of patients studied. The superior VMAT plan quality resulted in approximately 30% more monitor units than the eight-beam IMRT plans, but the delivery time was still less than 3 min. Conclusions: Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating prostate cancer.

  5. The impact of direct aperture optimization on plan quality and efficiency in complex head and neck IMRT

    Directory of Open Access Journals (Sweden)

    Sabatino Marcello

    2012-01-01

    Full Text Available Abstract Background Conventional step&shoot intensity modulated radio therapy (IMRT approaches potentially lead to treatment plans with high numbers of segments and monitor units (MU and, therefore, could be time consuming at the linear accelerator. Direct optimization methods are able to reduce the complexity without degrading the quality of the plan. The aim of this study is the evaluation of different IMRT approaches at standardized conditions for head and neck tumors. Method For 27 patients with carcinomas in the head and neck region a planning study with a 2-step-IMRT system (KonRad, a direct optimization system (Panther DAO and a mixture of both approaches (MasterPlan DSS was created. In order to avoid different prescription doses for boost volumes a simple standardization was realized. The dose was downscaled to 50 Gy to the planning target volume (PTV which included the primary tumor as well as the bilateral lymphatic drainage (cervical and supraclavicular. Dose restrictions for the organs at risk (OAR were downscaled to this prescription from high dose concepts up to 72 Gy. Those limits were defined as planning objectives while reaching definable PTV coverage with a standardized field setup. The parameters were evaluated from the corresponding dose volume histogram (DVH. Special attention was paid to the efficiency of the method, measured by means of calculated MU and required segments. Statistical tests of significance were applied to quantify the differences between the evaluated systems. Results PTV coverage for all systems in terms of V90% and V95% fell short of the requested 100% and 95%, respectively, but were still acceptable (range: 98.7% to 99.1% and 94.2% to 94.7%. Overall for OAR sparing and the burden of healthy tissue with low doses no technique was superior for all evaluated parameters. Differences were found for the number of segments where the direct optimization systems generated less segments. Lowest average numbers of

  6. The impact of direct aperture optimization on plan quality and efficiency in complex head and neck IMRT

    International Nuclear Information System (INIS)

    Sabatino, Marcello; Kretschmer, Matthias; Zink, Klemens; Würschmidt, Florian

    2012-01-01

    Conventional step&shoot intensity modulated radio therapy (IMRT) approaches potentially lead to treatment plans with high numbers of segments and monitor units (MU) and, therefore, could be time consuming at the linear accelerator. Direct optimization methods are able to reduce the complexity without degrading the quality of the plan. The aim of this study is the evaluation of different IMRT approaches at standardized conditions for head and neck tumors. For 27 patients with carcinomas in the head and neck region a planning study with a 2-step-IMRT system (KonRad), a direct optimization system (Panther DAO) and a mixture of both approaches (MasterPlan DSS) was created. In order to avoid different prescription doses for boost volumes a simple standardization was realized. The dose was downscaled to 50 Gy to the planning target volume (PTV) which included the primary tumor as well as the bilateral lymphatic drainage (cervical and supraclavicular). Dose restrictions for the organs at risk (OAR) were downscaled to this prescription from high dose concepts up to 72 Gy. Those limits were defined as planning objectives while reaching definable PTV coverage with a standardized field setup. The parameters were evaluated from the corresponding dose volume histogram (DVH). Special attention was paid to the efficiency of the method, measured by means of calculated MU and required segments. Statistical tests of significance were applied to quantify the differences between the evaluated systems. PTV coverage for all systems in terms of V 90% and V 95% fell short of the requested 100% and 95%, respectively, but were still acceptable (range: 98.7% to 99.1% and 94.2% to 94.7%). Overall for OAR sparing and the burden of healthy tissue with low doses no technique was superior for all evaluated parameters. Differences were found for the number of segments where the direct optimization systems generated less segments. Lowest average numbers of MU were 308 by Panther DAO calculated for

  7. Poster - Thur Eve - 29: Detecting changes in IMRT QA using statistical process control.

    Science.gov (United States)

    Drever, L; Salomons, G

    2012-07-01

    Statistical process control (SPC) methods were used to analyze 239 measurement based individual IMRT QA events. The selected IMRT QA events were all head and neck (H&N) cases with 70Gy in 35 fractions, and all prostate cases with 76Gy in 38 fractions planned between March 2009 and 2012. The results were used to determine if the tolerance limits currently being used for IMRT QA were able to indicate if the process was under control. The SPC calculations were repeated for IMRT QA of the same type of cases that were planned after the treatment planning system was upgraded from Eclipse version 8.1.18 to version 10.0.39. The initial tolerance limits were found to be acceptable for two of the three metrics tested prior to the upgrade. After the upgrade to the treatment planning system the SPC analysis found that the a priori limits were no longer capable of indicating control for 2 of the 3 metrics analyzed. The changes in the IMRT QA results were clearly identified using SPC, indicating that it is a useful tool for finding changes in the IMRT QA process. Routine application of SPC to IMRT QA results would help to distinguish unintentional trends and changes from the random variation in the IMRT QA results for individual plans. © 2012 American Association of Physicists in Medicine.

  8. IMRT fluence map editing to control hot and cold spots

    International Nuclear Information System (INIS)

    Taylor Cook, J.; Tobler, Matt; Leavitt, Dennis D.; Watson, Gordon

    2005-01-01

    Manually editing intensity-modulated radiation therapy (IMRT) fluence maps effectively controls hot and cold spots that the IMRT optimization cannot control. Many times, re-optimizing does not reduce the hot spots or increase the cold spots. In fact, re-optimizing only places the hot and cold spots in different locations. Fluence-map editing provides manual control of dose delivery and provides the best treatment plan possible. Several IMRT treatments were planned using the Varian Eclipse planning system. We compare the effects on dose distributions between fluence-map editing and re-optimization, discuss techniques for fluence-map editing, and analyze differences between fluence editing on one beam vs. multiple beams. When editing a beam's fluence map, it is essential to choose a beam that least affects dose to the tumor and critical structures. Editing fluence maps gives an advantage in treatment planning and provides controlled delivery of IMRT dose

  9. Current status of intensity-modulated radiation therapy (IMRT)

    International Nuclear Information System (INIS)

    Hatano, Kazuo; Araki, Hitoshi; Sakai, Mitsuhiro

    2007-01-01

    External-beam radiation therapy has been one of the treatment options for prostate cancer. The dose response has been observed for a dose range of 64.8-81 Gy. The problem of external-beam radiotherapy (RT) for prostate cancer is that as the dose increases, adverse effects also increase. Three-dimensional conformal radiation therapy (3D-CRT) has enabled us to treat patients with up to 72-76 Gy to the prostate, with a relatively acceptable risk of late rectal bleeding. Recently, intensity-modulated radiation therapy (IMRT) has been shown to deliver a higher dose to the target with acceptable low rates of rectal and bladder complications. The most important things to keep in mind when using an IMRT technique are that there is a significant trade-off between coverage of the target, avoidance of adjacent critical structures, and the inhomogeneity of the dose within the target. Lastly, even with IMRT, it should be kept in mind that a ''perfect'' plan that creates completely homogeneous coverage of the target volume and zero or small dose to the adjacent organs at risk is not always obtained. Participating in many treatment planning sessions and arranging the beams and beam weights create the best approach to the best IMRT plan. (author)

  10. Alterations of total non stimulated salivary flow in patients with squamous cell carcinoma of the mouth and oropharynx submitted to hyperfractionated radiation therapy

    International Nuclear Information System (INIS)

    Guebur, Maria Isabela; Rapoport, Abrao; Sassi, Laurindo Moacir; Oliveira, Benedito Valdecir de; Ramos, Gyl Henrique Albrecht; Pereira, Jose Carlos Gasparin

    2004-01-01

    Prevention and early diagnosis are actually the most effective measures that we dispose to improve the prognostic of the malignant tumors. The mouth and oropharynx tumors are treated with success, when early diagnosed. The radiotherapy is almost always one of the selected treatments for these tumors. When cancer is diagnosed in advanced stages, many a time the treatment needs to be carried out swiftly to be efficient, and consequently the radio therapist use the hyperfractionated therapy, with the patient receiving two lower doses of radiation in two sessions daily, amounting to a higher daily dosage, of about 160 cGy/2x/day. When the major salivary glands are present in the radiated field, the xerostomia appears by the second week of treatment (1500 to 2000 cGy), changing the patient's health, and causing difficulties for him to eat, speak and sleep. The objective of this study was to evaluate the quantitative alterations of the total non stimulated salivate flow of patients who underwent hyperfractionated therapy for the treatment of squamous cell carcinoma of mouth and oropharynx. Samples of twelve male patients saliva from Erasto Gaertner Hospital in Curitiba, PR, Brazil, were examined. Two samples of saliva were collected from each patient, the first one before the beginning of the radiotherapy, and the second at the end of the treatment. As a result, we obtained salivary loss in 91.7% of the patients, with a percentage of total salivary flow loss of 62.9%, registered in the second collection. We concluded that the hyperfractionated therapy causes a marked xerostomia when the major salivary glands are in the radiated field. (author)

  11. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    Directory of Open Access Journals (Sweden)

    Daniel L Saenz

    2014-01-01

    Full Text Available ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60 with 0.35 Tesla magnetic resonance imaging (MRI allows for magnetic resonance (MR-guided intensity-modulated radiation therapy (IMRT delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI, conformity index (CI, and volume receiving <20% of prescription dose (DRx were calculated to assess the plans. The 95% confidence intervals were recorded for all measurements and presented with the associated bars in graphs. The homogeneity index (D5/D95 had a 1-5% inhomogeneity increase for head and neck, 3-8% for lung, and 4-16% for prostate. CI revealed a modest conformity increase for lung. The volume receiving 20% of the prescription dose increased 2-8% for head and neck and up to 4% for lung and prostate. Overall, for head and neck Co-60 ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system.

  12. Hyperfractionated radiotherapy (2100 cGY) for stage 4 neuroblastoma as part of intensive multimodality therapy

    International Nuclear Information System (INIS)

    Gollamudi, S.V.; Kushner, B.H.; Merchant, T.E.; LaQuaglia, M.; Lindsley, K.; Rosenfield, N.; Abramson, S.; Kramer, K.; Cheung, N.K.V.

    1997-01-01

    PURPOSE: To retrospectively evaluate the role of hyperfractionated radiotherapy to the primary site following induction chemotherapy and aggressive surgical resection in patients (pts) with stage 4 neuroblastoma. MATERIALS AND METHODS: 48 previously untreated children (median age at diagnosis 3 yo, range 1-10 yo) with stage 4 neuroblastoma achieved a complete-, near-complete-, or partial-remission after multimodality therapy (protocol N4: 6 pts, N5: 7 pts, N6: 27 pts, or N7: 8 pts). All protocols included a regimen consisting of dose-intensive multiagent chemotherapy, maximal surgical debulking, followed by hyperfractionated radiotherapy. Most pts then underwent consolidation with either autologous marrow transplantation (N4 and N5), or immunotherapy (N6 and N7) with radioimmunotherapy (N7). Of 48 pts, 46 had microscopic disease at the primary site prior to beginning radiotherapy (45 underwent gross total resection of the primary, and one had no residual primary disease after chemotherapy alone). One pt had a partial resection, and one remained unresectable after mutimodality therapy. The pre-chemotherapy volume of the primary tumor and regional lymph nodes were irradiated to a total dose of 2100cGy delivered twice-daily in 150 cGy fractions over 7 treatment days. RESULTS: With a median follow-up of 32.5 months (range= 8-145 months), local-regional control was achieved in 44 of the 48 pts. Of the pts who are progression-free, median follow-up was 53.5 months. Overall, 24 of 48 pts progressed, three with local-regional recurrence as the first site of relapse, one with distant failure first and subsequent local-regional recurrence, and 21 with distant failure only. The probability of local-regional control at 32 months was 83%. One of the four pts with local-regional relapse never achieved a complete remission with either systemic therapy, surgical resection or radiotherapy. The progression-free survival at 32 months was 46%. Median time to overall progression was 16

  13. Patient reported outcome measures (PROMs) following forward planned field-in field IMRT: Results from the Cambridge Breast IMRT trial

    International Nuclear Information System (INIS)

    Mukesh, Mukesh B.; Qian, Wendi; Wilkinson, Jennifer S.; Dorling, Leila; Barnett, Gillian C.; Moody, Anne M.; Wilson, Charles; Twyman, Nicola; Burnet, Neil G.; Wishart, Gordon C.; Coles, Charlotte E.

    2014-01-01

    Background: The use of intensity-modulated radiotherapy (IMRT) in breast cancer reduces clinician-assessed breast tissue toxicity including fibrosis, telangectasia and sub-optimal cosmesis. Patient reported outcome measures (PROMs) are also important as they provide the patient’s perspective. This longitudinal study reports on (a) the effect of forward planned field-in-field IMRT (∼simple IMRT) on PROMs compared to standard RT at 5 years after RT, (b) factors affecting PROMs at 5 years after RT and (c) the trend of PROMs over 5 years of follow up. Methods: PROMs were assessed at baseline (pre-RT), 6, 24 and 60 months after completion of RT using global health (EORTC QLQ C30) and 4 breast symptom questions (BR23). Also, 4 breast RT-specific questions were included at 6, 24 and 60 months: change in skin appearance, firmness to touch, reduction in breast size and overall change in breast appearance since RT. The benefits of simple IMRT over standard RT at 5 years after RT were assessed using standard t-test for global health and logistic regression analysis for breast symptom questions and breast RT-specific questions. Clinical factors affecting PROMs at 5 years were investigated using a multivariate analysis. A repeated mixed model was applied to explore the trend over time for each of PROMs. Results: (89%) 727/815, 84%, 81% and 61% patients completed questionnaires at baseline, 6, 24 and 60 months respectively. Patients reported worse toxicity for all four BR23 breast symptoms at 6 months, which then improved over time (p < 0.0001). They also reported improvement in skin appearance and breast hardness over time (p < 0.0001), with no significant change for breast shrinkage (p = 0.47) and overall breast appearance (p = 0.13). At 5 years, PROMs assessments did not demonstrate a benefit for simple IMRT over standard radiotherapy. Large breast volume, young age, baseline surgical cosmesis and post-operative infection were the most important variables to affect PROMs

  14. Accelerated Partial Breast Irradiation With IMRT: New Technical Approach and Interim Analysis of Acute Toxicity in a Phase III Randomized Clinical Trial

    International Nuclear Information System (INIS)

    Livi, Lorenzo; Buonamici, Fabrizio Banci; Simontacchi, Gabriele; Scotti, Vieri; Fambrini, Massimiliano; Compagnucci, Antonella; Paiar, Fabiola; Scoccianti, Silvia; Pallotta, Stefania; Detti, Beatrice; Agresti, Benedetta; Talamonti, Cinzia; Mangoni, Monica; Bianchi, Simonetta; Cataliotti, Luigi; Marrazzo, Livia; Bucciolini, Marta; Biti, Giampaolo

    2010-01-01

    Purpose: To evaluate with a randomized clinical trial the possibility of treating the index quadrant with external intensity-modulated radiotherapy (IMRT) in a selected group of patients with early-stage breast cancer and to analyze the acute toxicity. Methods and Materials: From September 2005, a randomized Phase III clinical trial has been conducted to compare conventional (tangential field) fractionated whole breast treatment (Arm A) with accelerated partial breast irradiation plus intensity-modulated radiotherapy (Arm B). For intensity-modulated radiotherapy, the clinical target volume was drawn with a uniform 1-cm margin around the surgical clips in three dimensions. The ipsilateral and contralateral breast, ipsilateral and contralateral lung, heart, and spinal cord were contoured as organs at risk. All the regions of interest were contoured according to the International Commission on Radiation Units and Measurements reports 50 and 62 recommendations. Results: In September 2008, 259 patients were randomized and treated. The mean clinical target volume in Arm B was 44 cm 3 and the mean planning target volume was 123 cm 3 . The mean value of the ratio between the planning target volume and the ipsilateral breast volume was 21%. The rate of Grade 1 and Grade 2 acute skin toxicity was 22% and 19% in Arm A (Radiation Therapy Oncology Group scale), respectively. The tolerance in Arm B was excellent with only 5% Grade 1 and 0.8% Grade 2 acute skin toxicity. The planning constraints were fully satisfied in most patients. In a very few cases, this was not possible because of very unfavorable anatomy. Quality assurance procedures were performed according to our internal quality assurance protocol, with excellent results. Conclusion: In the present preliminary analysis, we have demonstrated that accelerated partial breast irradiation is feasible, with very low acute toxicity.

  15. Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.

    Science.gov (United States)

    Netherton, Tucker; Li, Yuting; Nitsch, Paige; Shaitelman, Simona; Balter, Peter; Gao, Song; Klopp, Ann; Muruganandham, Manickam; Court, Laurence

    2018-06-01

    Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. To study lung interplay, eight VMAT plans (1-6 arcs) and four-nine-field sliding-window IMRT plans varying in complexity were created. For the breast plans, four-four-field sliding-window IMRT plans were created. Using the Halcyon 1.0 linear accelerator, each plan was delivered five times each under sinusoidal breathing motion to a phantom with 20 implanted MOSFET detectors; MOSFET dose (cGy), delivery time, and MU/cGy values were recorded. Maximum and mean dose deviations were calculated from MOSFET data. The number of MOSFETs with at least 19 of 20 detectors agreeing with their expected dose within 5% per fraction was calculated across 10 6 iterations to model dose deviation as function of fraction number for all plan variants. To put interplay plans into clinical context, additional IMRT and VMAT plans were created and delivered for the sites of head and neck, prostate, whole brain, breast, pelvis, and lung. Average modulation and interplay effect were compared to those from conventional linear accelerators, as reported from previous studies. The mean beam modulation for plans created for the Halcyon 1.0 linear accelerator was 2.9 MU/cGy (two- to four-field IMRT breast plans), 6.2 MU/cGy (at least five-field IMRT), and 3.6 MU/cGy (four-arc VMAT). To achieve treatment plan objectives, Halcyon 1.0 VMAT plans require more arcs and modulation than VMAT on conventional linear accelerators. Maximum and mean dose deviations increased with increasing plan complexity under tumor motion for breast and lung treatments. Concerning VMAT plans under motion, maximum, and mean dose deviations were higher for one arc than for two arcs regardless of plan complexity. For plan variants

  16. Hyperfractionated total body irradiation for T-depleted HLA identical bone marrow transplants

    International Nuclear Information System (INIS)

    Latini, P.; Checcaglini, F.; Maranzano, E.; Aristei, C.; Panizza, B.M.; Gobbi, G.; Raymondi, C.; Aversa, F.; Martelli, M.F.

    1988-01-01

    Twenty patients suffering from malignant hemopathies (mean age 31.7 years) were given hyperfractionated total body irradiation (TBI) as conditioning for T-depleted HLA identical allogeneic bone marrow transplantation. At an average of 12 months (range of 4.5-22 months) follow-up there were two cases of early death and two cases (11%) of rejection. There were no cases of acute or chronic graft versus host disease nor cases of interstitial pneumonitis. The average time for durable engraftment was 22 days. Disease-free survival at 12 months was 65%. To improve the results and further reduce the percent of rejection, the authors propose intensifying the immunosuppressive conditioning by increasing the cyclophosphamide dose and that of TBI so that a total dose of 1560 cGy is reached. 35 refs.; 1 figure

  17. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.

    Science.gov (United States)

    Sikora, M; Dohm, O; Alber, M

    2007-08-07

    A dedicated, efficient Monte Carlo (MC) accelerator head model for intensity modulated stereotactic radiosurgery treatment planning is needed to afford a highly accurate simulation of tiny IMRT fields. A virtual source model (VSM) of a mini multi-leaf collimator (MLC) (the Elekta Beam Modulator (EBM)) is presented, allowing efficient generation of particles even for small fields. The VSM of the EBM is based on a previously published virtual photon energy fluence model (VEF) (Fippel et al 2003 Med. Phys. 30 301) commissioned with large field measurements in air and in water. The original commissioning procedure of the VEF, based on large field measurements only, leads to inaccuracies for small fields. In order to improve the VSM, it was necessary to change the VEF model by developing (1) a method to determine the primary photon source diameter, relevant for output factor calculations, (2) a model of the influence of the flattening filter on the secondary photon spectrum and (3) a more realistic primary photon spectrum. The VSM model is used to generate the source phase space data above the mini-MLC. Later the particles are transmitted through the mini-MLC by a passive filter function which significantly speeds up the time of generation of the phase space data after the mini-MLC, used for calculation of the dose distribution in the patient. The improved VSM model was commissioned for 6 and 15 MV beams. The results of MC simulation are in very good agreement with measurements. Less than 2% of local difference between the MC simulation and the diamond detector measurement of the output factors in water was achieved. The X, Y and Z profiles measured in water with an ion chamber (V = 0.125 cm(3)) and a diamond detector were used to validate the models. An overall agreement of 2%/2 mm for high dose regions and 3%/2 mm in low dose regions between measurement and MC simulation for field sizes from 0.8 x 0.8 cm(2) to 16 x 21 cm(2) was achieved. An IMRT plan film verification

  18. Heterogeneity in head and neck IMRT target design and clinical practice

    International Nuclear Information System (INIS)

    Hong, Theodore S.; Tomé, Wolfgang A.; Harari, Paul M.

    2012-01-01

    Purpose: To assess patterns of H and N IMRT practice with particular emphasis on elective target delineation. Materials and methods: Twenty institutions with established H and N IMRT expertise were solicited to design clinical target volumes for the identical H and N cancer case. To limit contouring variability, a primary tonsil GTV and ipsilateral level II node were pre-contoured. Participants were asked to accept this GTV, and contour their recommended CTV and PTV. Dose prescriptions, contouring time, and recommendations regarding chemotherapy were solicited. Results: All 20 institutions responded. Remarkable heterogeneity in H and N IMRT design and practice was identified. Seventeen of 20 centers recommended treatment of bilateral necks whereas 3/20 recommended treatment of the ipsilateral neck only. The average CTV volume was 250 cm 3 (range 37–676 cm 3 ). Although there was high concordance in coverage of ipsilateral neck levels II and III, substantial variation was identified for levels I, V, and the contralateral neck. Average CTV expansion was 4.1 mm (range 0–15 mm). Eight of 20 centers recommended chemotherapy (cisplatin), whereas 12/20 recommended radiation alone. Responders prescribed on average 69 and 68 Gy to the tumor and metastatic node GTV, respectively. Average H and N target volume contouring time was 102.5 min (range 60–210 min). Conclusion: This study identifies substantial heterogeneity in H and N IMRT target definition, prescription, neck treatment, and use of chemotherapy among practitioners with established H and N IMRT expertise. These data suggest that continued efforts to standardize and simplify the H and N IMRT process are desirable for the safe and effective global advancement of H and N IMRT practice.

  19. Minimum monitor unit per segment IMRT planning and over-shoot-ratio

    International Nuclear Information System (INIS)

    Grigorov, G.; Barnett, R.; Chow, J.

    2004-01-01

    The aim of this work is to describe the modulation quality for dose delivery of small Multi-Leaf Collimator (MLC) fields and MU/segment. The results were obtained with Pinnacle (V6) and a Varian Clinac 2100 EX (Varis 6.2) linear accelerator. The over-shoot effect was investigated by comparing integrated multiple segmented exposures to a single exposure with the same number of total MU (1, 2, 3,4, 5 and 6 MU). To present the OS effect the Over-Shoot-Ratio (OSR) was defined as the ratio of the segmented dose for a 1 cm 2 field at depth to the static dose for the same field size and depth. OSR was measured as a function of MU/segment and dose rate. Measured results can be used to optimise IMRT planning and also to calculate the surface dose. The dependence of the dose in depth with 1, 2, 3, 4, and 5 MU/segments for 6 MV photon beam, dose rate of 100 MU/min and 1 cm 2 beam field at the central axis is presented, where the argument of the function is the depth and parameter of the function is the number of minimum MU/segment. The dependence of the overshoot ratio on the MU/segment with a parameter of the dose rates (100, 400 and 600 MU/min) is also shown. The effect increases with the dose rate and decreases with the increasing of the minimum number of MU/segment. Having measured OSR for the 2100 EX linac it is possible to do correction and calibration of the dose of the first segment of IMRT beam, where the dose to the target and on the surface can increase over the planed dose of 1 MU by 40% and 70% for dose rate of 400 and 600 MU/min respectively. The Over-Shoot-Ratio is an important parameter to be determined as part of the routine quality assurance for IMRT and can be used to significantly improve the agreement between planned and delivered doses to the patient

  20. Comparison of VMAT and IMRT strategies for cervical cancer patients using automated planning.

    Science.gov (United States)

    Sharfo, Abdul Wahab M; Voet, Peter W J; Breedveld, Sebastiaan; Mens, Jan Willem M; Hoogeman, Mischa S; Heijmen, Ben J M

    2015-03-01

    In a published study on cervical cancer, 5-beam IMRT was inferior to single arc VMAT. Here we compare 9, 12, and 20 beam IMRT with single and dual arc VMAT. For each of 10 patients, automated plan generation with the in-house Erasmus-iCycle optimizer was used to assist an expert planner in generating the five plans with the clinical TPS. For each patient, all plans were clinically acceptable with a high and similar PTV coverage. OAR sparing increased when going from 9 to 12 to 20 IMRT beams, and from single to dual arc VMAT. For all patients, 12 and 20 beam IMRT were superior to single and dual arc VMAT, with substantial variations in gain among the study patients. As expected, delivery of VMAT plans was significantly faster than delivery of IMRT plans. Often reported increased plan quality for VMAT compared to IMRT has not been observed for cervical cancer. Twenty and 12 beam IMRT plans had a higher quality than single and dual arc VMAT. For individual patients, the optimal delivery technique depends on a complex trade-off between plan quality and treatment time that may change with introduction of faster delivery systems. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Comparison of VMAT and IMRT strategies for cervical cancer patients using automated planning

    International Nuclear Information System (INIS)

    Sharfo, Abdul Wahab M.; Voet, Peter W.J.; Breedveld, Sebastiaan; Mens, Jan Willem M.; Hoogeman, Mischa S.; Heijmen, Ben J.M.

    2015-01-01

    Background and purpose: In a published study on cervical cancer, 5-beam IMRT was inferior to single arc VMAT. Here we compare 9, 12, and 20 beam IMRT with single and dual arc VMAT. Material and methods: For each of 10 patients, automated plan generation with the in-house Erasmus-iCycle optimizer was used to assist an expert planner in generating the five plans with the clinical TPS. Results: For each patient, all plans were clinically acceptable with a high and similar PTV coverage. OAR sparing increased when going from 9 to 12 to 20 IMRT beams, and from single to dual arc VMAT. For all patients, 12 and 20 beam IMRT were superior to single and dual arc VMAT, with substantial variations in gain among the study patients. As expected, delivery of VMAT plans was significantly faster than delivery of IMRT plans. Conclusions: Often reported increased plan quality for VMAT compared to IMRT has not been observed for cervical cancer. Twenty and 12 beam IMRT plans had a higher quality than single and dual arc VMAT. For individual patients, the optimal delivery technique depends on a complex trade-off between plan quality and treatment time that may change with introduction of faster delivery systems

  2. Comments on shielding for dual energy accelerators

    International Nuclear Information System (INIS)

    Rossi, M. C.; Lincoln, H. M.; Quarin, D. J.; Zwicker, R. D.

    2008-01-01

    Determination of shielding requirements for medical linear accelerators has been greatly facilitated by the publication of the National Council on Radiation Protection and Measurements (NCRP) latest guidelines on this subject in NCRP Report No. 151. In the present report the authors review their own recent experience with patient treatments on conventional dual energy linear accelerators to examine the various input parameters needed to follow the NCRP guidelines. Some discussion is included of workloads, occupancy, use factors, and field size, with the effects of intensity modulated radiotherapy (IMRT) treatments included. Studies of collimator settings showed average values of 13.1x16.2 cm 2 for 6 MV and 14.1x16.8 cm 2 for 18 MV conventional ports, and corresponding average unblocked areas of 228 and 254 cm 2 , respectively. With an average of 77% of the field area unblocked, this gives a mean irradiated area of 196 cm 2 for the 18 MV beam, which dominates shielding considerations for most dual energy machines. Assuming conservatively small room dimensions, a gantry bin angle of 18 deg. was found to represent a reasonable unit for tabulation of use factors. For conventional 18 MV treatments it was found that the usual treatment angles of 0, 90, 180, and 270 deg. were still favored, and use factors of 0.25 represent reasonable estimates for these beams. As expected, the IMRT fields (all at 6 MV) showed a high degree of gantry angle randomization, with no bin having a use factor in excess of 0.10. It is concluded that unless a significant number of patients are treated with high energy IMRT, the traditional use factors of 0.25 are appropriate for the dominant high energy beam

  3. Comments on shielding for dual energy accelerators.

    Science.gov (United States)

    Rossi, M C; Lincoln, H M; Quarin, D J; Zwicker, R D

    2008-06-01

    Determination of shielding requirements for medical linear accelerators has been greatly facilitated by the publication of the National Council on Radiation Protection and Measurements (NCRP) latest guidelines on this subject in NCRP Report No. 151. In the present report the authors review their own recent experience with patient treatments on conventional dual energy linear accelerators to examine the various input parameters needed to follow the NCRP guidelines. Some discussion is included of workloads, occupancy, use factors, and field size, with the effects of intensity modulated radiotherapy (IMRT) treatments included. Studies of collimator settings showed average values of 13.1 x 16.2 cm2 for 6 MV and 14.1 x 16.8 cm2 for 18 MV conventional ports, and corresponding average unblocked areas of 228 and 254 cm2, respectively. With an average of 77% of the field area unblocked, this gives a mean irradiated area of 196 cm2 for the 18 MV beam, which dominates shielding considerations for most dual energy machines. Assuming conservatively small room dimensions, a gantry bin angle of 18 degrees was found to represent a reasonable unit for tabulation of use factors. For conventional 18 MV treatments it was found that the usual treatment angles of 0, 90, 180, and 270 degrees were still favored, and use factors of 0.25 represent reasonable estimates for these beams. As expected, the IMRT fields (all at 6 MV) showed a high degree of gantry angle randomization, with no bin having a use factor in excess of 0.10. It is concluded that unless a significant number of patients are treated with high energy IMRT, the traditional use factors of 0.25 are appropriate for the dominant high energy beam.

  4. Prostate Dose Escalation by a Innovative Inverse Planning-Driven IMRT

    National Research Council Canada - National Science Library

    Xing, Lei

    2008-01-01

    ...) Developed a voxel-specific penalty scheme for TRV-based inverse planning; (iv) Established a cine-EPID image retrospective dose reconstruction in IMRT dose delivery for adaptive planning and IMRT dose verification. These works are both timely and important and should lead to widespread impact on prostate cancer management.

  5. Phase I/II Trial of Hyperfractionated Concomitant Boost Proton Radiotherapy for Supratentorial Glioblastoma Multiforme

    International Nuclear Information System (INIS)

    Mizumoto, Masashi; Tsuboi, Koji; Igaki, Hiroshi; Yamamoto, Tetsuya; Takano, Shingo; Oshiro, Yoshiko; Hayashi, Yasutaka; Hashii, Haruko; Kanemoto, Ayae; Nakayama, Hidetsugu; Sugahara, Shinji; Sakurai, Hideyuki; Matsumura, Akira; Tokuuye, Koichi

    2010-01-01

    Purpose: To evaluate the safety and efficacy of postoperative hyperfractionated concomitant boost proton radiotherapy with nimustine hydrochloride for supratentorial glioblastoma multiforme (GBM). Methods and Materials: Twenty patients with histologically confirmed supratentorial GBM met the following criteria: (1) a Karnofsky performance status of ≥60; (2) the diameter of the enhanced area before radiotherapy was ≤40 cm; and (3) the enhanced area did not extend to the brain stem, hypothalamus, or thalamus. Magnetic resonance imaging (MRI) T 2 -weighted high area (clinical tumor volume 3 [CTV3]) was treated by x-ray radiotherapy in the morning (50.4 Gy in 28 fractions). More than 6 hours later, 250 MeV proton beams were delivered to the enhanced area plus a 10-mm margin (CTV2) in the first half of the protocol (23.1 GyE in 14 fractions) and to the enhanced volume (CTV1) in the latter half (23.1 GyE in 14 fraction). The total dose to the CTV1 was 96.6 GyE. Nimustine hydrochloride (80 mg/m2) was administered during the first and fourth weeks. Results: Acute toxicity was mainly hematologic and was controllable. Late radiation necrosis and leukoencephalopathy were each seen in one patient. The overall survival rates after 1 and 2 years were 71.1% and 45.3%, respectively. The median survival period was 21.6 months. The 1- and 2-year progression-free survival rates were 45.0% and 15.5%, respectively. The median MRI change-free survival was 11.2 months. Conclusions: Hyperfractionated concomitant boost proton radiotherapy (96.6 GyE in 56 fractions) for GBM was tolerable and beneficial if the target size was well considered. Further studies are warranted to pursue the possibility of controlling border region recurrences.

  6. Virtual couch shift (VCS): accounting for patient translation and rotation by online IMRT re-optimization

    International Nuclear Information System (INIS)

    Bol, G H; Lagendijk, J J W; Raaymakers, B W

    2013-01-01

    When delivering conventional intensity modulated radiotherapy (IMRT), discrepancies between the pre-treatment CT/MRI/PET based patient geometry and the daily patient geometry are minimized by performing couch translations and/or small rotations. However, full compensation of, in particular, rotations is usually not possible. In this paper, we introduce an online ‘virtual couch shift (VCS)’: we translate and/or rotate the pre-treatment dose distribution to compensate for the changes in patient anatomy and generate a new plan which delivers the transformed dose distribution automatically. We show for a phantom and a cervical cancer patient case that VCS accounts for both translations and large rotations equally well in terms of DVH results and 2%/2 mm γ analyses and when the various aspects of the clinical workflow can be implemented successfully, VCS can potentially outperform physical couch translations and/or rotations. This work is performed in the context of our hybrid 1.5 T MRI linear accelerator, which can provide translations and rotations but also deformations of the anatomy. The VCS is the first step toward compensating all of these anatomical changes by online re-optimization of the IMRT dose distribution. (paper)

  7. Dosimetry audit for a multi-centre IMRT head and neck trial

    International Nuclear Information System (INIS)

    Clark, Catharine H.; Hansen, Vibeke Nordmark; Chantler, Hannah; Edwards, Craig; James, Hayley V.; Webster, Gareth; Miles, Elizabeth A.; Guerrero Urbano, M. Teresa; Bhide, Shree A.; Bidmead, A. Margaret; Nutting, Christoper M.

    2009-01-01

    Background and purpose: PARSPORT was a multi-centre randomised trial in the UK which compared Intensity-Modulated Radiotherapy (IMRT) and conventional radiotherapy (CRT) for patients with head and neck cancer. The dosimetry audit goals were to verify the plan delivery in participating centres, ascertain what tolerances were suitable for head and neck IMRT trials and develop an IMRT credentialing program. Materials and methods: Centres enrolling patients underwent rigorous quality assurance before joining the trial. Following this each centre was visited for a dosimetry audit, which consisted of treatment planning system tests, fluence verification films, combined field films and dose point measurements. Results: Mean dose point measurements were made at six centres. For the primary planning target volume (PTV) the differences with the planned values for the IMRT and CRT arms were -0.6% (1.8% to -2.4%) and 0.7% (2.0% to -0.9%), respectively. Ninety-four percent of the IMRT fluence films for individual fields passed gamma criterion of 3%/3 mm and 75% of the films for combined fields passed gamma criterion 4%/3 mm (no significant difference between dynamic delivery and step and shoot delivery). Conclusions: This audit suggests that a 3% tolerance could be applied for PTV point doses. For dose distributions tolerances of 3%/3 mm on individual fields and 4%/3 mm for combined fields are proposed for multi-centre head and neck IMRT trials.

  8. Phase I and pharmacologic study of 72-hour infused 5-fluorouracil and hyperfractionated cyclical radiation

    Energy Technology Data Exchange (ETDEWEB)

    Byfield, J.E.; Frankel, S.S.; Sharp, T.R.; Hornbeck, C.L.; Callipari, F.B.

    1985-04-01

    The authors have studied 21 patients infused for 72 hours with 5- Fluorouracil (5-FU) at progressive doses combined with hyperfractionated radiation. The schedule was chosen as being one capable of inducing 5-FU radiosensitization (RS). All patients were started at a daily 5-FU dose of 40 mg/kg/24 hours; doses were then escalated with each subsequent treatment cycle to limiting toxicity or until taken off study. Patients received between one and six infusion cycles. Every treatment cycle included coincident hyperfractionated radiation to various body areas including the abdomen, chest, and head and neck region. Radiation fractionation was invariant; 1,000 rad were delivered in four equal fractions. Two fractions of 250 rad each were given on days 1 and 2 of each three day 5-FU cycle, i.e. at approximately 0, 8, 24, and 32 hours into the drug infusion. Patients were followed for toxicity; serum 5-FU concentrations were determined using a high pressure liquid chromatographic assay. 5-FU clearances were calculated from the mean serum drug levels and the infused drug dose. The toxicity spectrum was not found to be significantly different from infused drug alone in this dose range except when the head and neck region received coincident irradiation. In that region the two anticipated toxicities combined in what appears to be a synergistic fashion to enhance mucositis. Most toxicities including gastrointestinal and bone marrow appeared dependent on the mean serum 5-FU level as did mucositis itself. 5-FU clearance was found to be non-linear in this dose region but did not appear influenced by radiation to any part of the body.

  9. Hyperfractionated Radiotherapy with Concomitant Boost Technique for Unresectable Non-Small Cell Carcinoma of the Lung

    International Nuclear Information System (INIS)

    Chun, Ha Chung; Lee, Myung Za

    1991-01-01

    Twenty five patients with unresectable non-small cell carcinoma of the lung have been treated with hyperfractionated radiotherapy with concomitant boost technique since September, 1989. Those patients with history of previous surgery or chemotherapy, pleural effusion or significant weight loss (greater than 10% of body weight) were excluded from the study. Initially, 27 Gy were delivered in 15 fractions in 3 weeks to the large field. Thereafter, large field received 1.8 Gy and cone down boost field received 1.4Gy with twice a day fractinations up to 49.4Gy. After 49.4Gy, only boost field was treated twice a day with 1.8 and 1.4 Gy. Total tumor doses were 62.2Gy for 12 patients and 65.4Gy for remaining 13 patients. Follow up period was ranged from 6 to 24 month. Actuarial survival rates at 6, 12, and 18 month were 88%, 62%, and 38%, respectively. Corresponding disease free survival rates were 88%, 41%, and 21%, respectively. Actuarial cumulative local failure rates at 9,12 and 15 month were 36%, 42%, and 59%, respectively. No significant increase of acute or late complications including radiation pneumonitis was noted with maximum follow up of 24 month. Although the longer follow up is needed, it is worthwhile to try the prospective randomized study to evaluate the efficacy of hyperfractionated radiotherapy with concomitant boost technique for unresectable non-small cell lung cancers in view of excellent tolerance of this treatment. In the future, further increase of total radiation dose might be necessary to improve local control for non-small cell lung cancer

  10. Phase I and pharmacologic study of 72-hour infused 5-fluorouracil and hyperfractionated cyclical radiation

    International Nuclear Information System (INIS)

    Byfield, J.E.; Frankel, S.S.; Sharp, T.R.; Hornbeck, C.L.; Callipari, F.B.

    1985-01-01

    The authors have studied 21 patients infused for 72 hours with 5- Fluorouracil (5-FU) at progressive doses combined with hyperfractionated radiation. The schedule was chosen as being one capable of inducing 5-FU radiosensitization (RS). All patients were started at a daily 5-FU dose of 40 mg/kg/24 hours; doses were then escalated with each subsequent treatment cycle to limiting toxicity or until taken off study. Patients received between one and six infusion cycles. Every treatment cycle included coincident hyperfractionated radiation to various body areas including the abdomen, chest, and head and neck region. Radiation fractionation was invariant; 1,000 rad were delivered in four equal fractions. Two fractions of 250 rad each were given on days 1 and 2 of each three day 5-FU cycle, i.e. at approximately 0, 8, 24, and 32 hours into the drug infusion. Patients were followed for toxicity; serum 5-FU concentrations were determined using a high pressure liquid chromatographic assay. 5-FU clearances were calculated from the mean serum drug levels and the infused drug dose. The toxicity spectrum was not found to be significantly different from infused drug alone in this dose range except when the head and neck region received coincident irradiation. In that region the two anticipated toxicities combined in what appears to be a synergistic fashion to enhance mucositis. Most toxicities including gastrointestinal and bone marrow appeared dependent on the mean serum 5-FU level as did mucositis itself. 5-FU clearance was found to be non-linear in this dose region but did not appear influenced by radiation to any part of the body

  11. The MLC tongue-and-groove effect on IMRT dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Deng Jun [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305 (United States). E-mail: jun@reyes.stanford.edu; Pawlicki, Todd; Chen Yan; Li Jinsheng; Jiang, Steve B.; Ma, C.-M. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305 (United States)

    2001-04-01

    We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groove effect could be up to 10% of the maximum dose in the dose distributions. For an IMRT treatment with multiple gantry angles ({>=} 5), the difference between the dose distributions with and without the tongue-and-groove effect was hardly visible, less than 1.6% for the two typical clinical cases studied. After considering the patient setup errors, the dose distributions were smoothed with reduced and insignificant differences between plans with and without the tongue-and-groove effect. Therefore, for a multiple-field IMRT plan ({>=} 5), the tongue-and-groove effect on the IMRT dose distributions will be generally clinically insignificant due to the smearing effect of individual fields. The tongue-and-groove effect on an IMRT plan with small number of fields (<5) will vary depending on the number of fields in a plan (coplanar or non-coplanar), the MLC leaf sequences and the patient setup uncertainty, and may be significant (>5% of maximum dose) in some cases, especially when the patient setup uncertainty is small ({<=} 2 mm). (author)

  12. Surviving Hypopharynx-Larynx Carcinoma in the Era of IMRT

    International Nuclear Information System (INIS)

    Studer, Gabriela; Peponi, Evangelia; Kloeck, Stephan; Dossenbach, Thomas; Huber, Gerhard; Glanzmann, Christoph

    2010-01-01

    Purpose: Outcome in locoregionally advanced laryngeal carcinoma and hypopharyngeal carcinoma after conventional radiation techniques is known for modest disease control and considerable late toxicity. Considering the lack of standardization in prescription dose for intensity-modulated radiotherapy (IMRT), we aimed to compare the results after our methods of simultaneously integrated boost IMRT with published results. Methods and Materials: Between March 2002 and December 2008, 65 hypopharyngeal, 31 supraglottic, and 27 locoregionally advanced glottic tumor patients underwent definitive IMRT (with simultaneous chemotherapy in 86%). Of these, 64% presented with locoregionally advanced disease. Mean follow-up was 26 months (range, 3-83 months), with a median of 21 months. Treatment (2.0-2.2Gy per fraction, 66-72.6Gy) followed a prospectively defined protocol. If the boost volume included more than half of the larynx or a substantial part of the pharynx, dose was limited to 2.0Gy per fraction. Results: The 2-year local, nodal, and locoregional control (LRC) rates for the entire cohort were 82%, 90%, and 77%, respectively; the disease-free and overall survival rates were 75% and 83%, respectively. The ultimate 2-year LRC rate, including salvage surgery, was 86%. Laryngectomy was required in 2 LRC patients needing tracheostoma already before; 2 further LRC patients needed tracheostomy before IMRT and remained tracheostoma dependent, and 3 patients remained feeding tube dependent after IMRT. Salvage laryngectomy was successful in 8 of 11. Of all 123 patients, 91 patients (74%) are locoregionally controlled and live with a functional laryngopharynx. Conclusions: Simultaneously integrated boost IMRT with limited acceptance of dose inhomogeneity resulted in very satisfactory disease control despite a slight left shift of planning target volume curves on the dose-volume histogram. Considering the treatment tolerance, a careful increase in dose in our patients seems possible

  13. Fluence complexity for IMRT field and simplification of IMRT verification

    International Nuclear Information System (INIS)

    Hanushova, Tereza; Vondarchek, Vladimir

    2013-01-01

    Intensity Modulated Radiation Therapy (IMRT) requires dosimetric verification of each patient’s plan, which is time consuming. This work deals with the idea of minimizing the number of fields for control, or even replacing plan verification by machine quality assurance (QA). We propose methods for estimation of fluence complexity in an IMRT field based on dose gradients and investigate the relation between results of gamma analysis and this quantity. If there is a relation, it might be possible to only verify the most complex field of a plan. We determine the average fluence complexity in clinical fields and design a test fluence corresponding to this amount of complexity which might be used in daily QA and potentially replace patient-related verification. Its applicability is assessed in clinical practice. The relation between fluence complexity and results of gamma analysis has been confirmed for plans but not for single fields. There is an agreement between the suggested test fluence and clinical fields in the average gamma parameter. A critical value of average gamma has been specified for the test fluence as a criterion for distinguishing between poorly and well deliverable plans. It will not be possible to only verify the most complex field of a plan but verification of individual plans could be replaced by a morning check of the suggested test fluence, together with a well-established set of QA tests. (Author)

  14. Induction chemotherapy followed by simultaneous hyperfractionated radiochemotherapy in advanced head and neck cancer. A pilot study

    International Nuclear Information System (INIS)

    Jereczek-Fossa, B.; Medical Univ. Gdansk; De Braud, F.; Gasparetto, M.; De Pas, T.; Tradati, N.; Leonardi, M.C.; Marsiglia, H.R.; Orecchia, R.; Milan Univ.

    1998-01-01

    Purpose: To evaluate the feasibility of induction chemotherapy followed by concomitant chemotherapy and hyperfractionated irradiation in locally advanced, inoperable head and neck cancer. Methods: A pilot study was undertaken comprising 3 cycles of cisplatinum (100 mg/m 2 , day 1) and 5-fluorouracil (1000 mg/m 2 in continuous intravenous infusion over the first 120 h) followed by bifractionated radiotherapy applied to tumor/involved lymph nodes up to the dose of 74.4 Gy given in 2 fractions of 1.2 Gy daily for 5 days a week combined with concomitant weekly cisplatinum infusion (50 mg/m 2 ). Results: Six patients were enrolled in the study. All of them completed the protocol therapy. Severe mucositis and myelotoxicity were the most common acute side effects observed in all and in 5 of the patients, respectively. Acute toxicity required interruption of concomitant chemotherapy in 5 cases and in 2 interruption of radiotherapy was necessary. Opioid analgesic parenteral therapy was administered in 4 patients. Three of them had to be hospitalized. One patient experienced cerebral stroke 1 day after the completion of therapy and died 7 days later. Due to high acute toxicity, patient accrual was terminated after 6 patients. At the mean follow-up of 17 months, 4 patients are alive, 3 of them are free of disease and in 1 local progression has been diagnosed. Conclusions: High acute toxicity of induction cisplatinum and 5-fluorouracil followed by concomitant cisplatinum and hyperfractionated irradiation calls for less toxic treatment schedules in locally advanced inoperable head and neck cancer. (orig.) [de

  15. Treatment of 29 patients with bulky squamous cell carcinoma of the cervix with simultaneous cisplatin, 5-fluorouracil, and split-course hyperfractionated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Heaton, D.; Yordan, E.; Reddy, S.; Bonomi, P.; Lee, M.S.; Lincoln, S.; Graham, J.; Dolan, T.; Miller, A.; Phillips, A. (Rush Presbyterian-St. Lukes Hospital, Chicago, IL (USA))

    1990-09-01

    Attempting to improve local disease control in bulky primary or recurrent pelvic tumors, 29 patients with squamous cell carcinoma of the cervix were treated with concomitant chemotherapy and split-course hyperfractionated radiation therapy between April 1983 and August 1988. Cisplatin (CDDP) and 5-fluorouracil (5-FU) have been shown to be radiation enhancers; furthermore, CDDP, radiation therapy, and continuous-infusion 5-FU have elicited high local response rates in head and neck squamous cell carcinoma. A pilot study of cyclical week on/week off CDDP, continuous-infusion 5-FU, and hyperfractionated radiation therapy was developed. Radiation was administered at 116 cGy twice daily, Days 1-5, every other week for a median dose of 4600 cGy to a pelvic field, with paraaortic extension if indicated. Concomitant chemotherapy included CDDP 60 mg/m2 IV Day 1 and 5-FU 600 mg/m2 IV continuous infusion for 96 hr following CDDP infusion. Patients received a median of four cycles of combined treatment, and intracavitary or interstitial brachytherapy followed in 21 patients. Local pelvic response was achieved in 29 of 29 (100%): complete response (CR) in 19 of 29 (66%), partial response (PR) in 10 of 29 (34%). Among CR patients 10 of 19 (53%) were without evidence of disease at a mean follow-up of 29 (range 12-76) months. Five-year actuarial disease-free survival among complete responders was 65%. Of the 10 CR patients 2 failed in the pelvis, for a local control rate of 17/19 (89%). Chemotherapy-related and acute radiation morbidity was minimal but 2 patients required surgical correction of radiation injury. Aggressive combination of split-course hyperfractionated radiation therapy with radiation enhancers resulted in promising local control of bulky pelvic tumor, with an acceptable complication rate, in this otherwise very poor prognostic group of patients.

  16. Q A IMRT comparison specific patient by means of radiochromic films, radiographic films and ionization chambers arrangement; Comparacion de QA IMRT paciente especifico mediante films radiocromicos, films radiograficos y arreglo de camaras de ionizacion

    Energy Technology Data Exchange (ETDEWEB)

    Medina, L.; Venencia, D.; Garrigo, E., E-mail: fisicamedina11@gmail.com [Instituto Privado de Radioterapia, Obispo Oro 423, X5000BFI Cordoba (Argentina)

    2014-08-15

    IMRT uses radiation beams of nonuniform intensity. Quality assurance (Q A) specific patient is mandatory in this treatment modality. The purpose of this study is to compare results of patient specific Q A IMRT dose distributions of the total plan and individual fields using different dosimetric systems. We used a photon beam 6 MV generated for linear accelerator PRIMUS, were used planning systems iPLAN and Konrad for IMRT inverse planning with modality Step and Shoot. For plans total dose distributions were measured with radiographic films EDR2 and Radiochromic Film EBT3. For individual fields the dose distributions were measured with radiographic films X-Omat-V, Radiochromic Film EBT3 and PTW 2D-Array. We used a scanner VIDAR Dosimetry Pro Red and software Rit v6.1 for analysis, was used Gamma index [Γ] for comparison of measured and calculated dose recording the number of pixels with Γ> 1. We analyzed 50 plan dose distributions total 50 individual fields. For the total plan the number of pixels with Γ>1 (3%-3m m) was 0.7%±1.2 [0.1%; 2.82%] for EBT3 y 1%±1.8 [0.2%; 3%] for EDR2. For individual fields (5%-3m m) was obtained 0.97%±1,7 [0%, 3%] for X-Omat-V, 0.84%±1.1[0.3%,3.1%] for EBT3 and 2.6%±1.9 [0.01%,6.8%] PTW 2D-Array. All three methods can be used. Radiochromic Films revealed the advantage and disadvantage of the cost. Both systems are slightly better film to PTW 2D-Array. (author)

  17. Hyperfractionated radiation in combination with local hyperthermia in the treatment of advanced squamous cell carcinoma of the head and neck: a phase I-II study

    International Nuclear Information System (INIS)

    Amichetti, Maurizio; Romano, Mario; Busana, Lucia; Bolner, Andrea; Fellin, Gianni; Pani, Giuseppe; Tomio, Luigi; Valdagni, Riccardo

    1997-01-01

    Twenty-seven patients with cervical metastases from squamous cell head and neck tumours were treated with hyperfractionated XRT (total dose 69.60-76.80 Gy, 1.2 Gy b.i.d. five times a week) combined with a total of two to six sessions of superficial external HT. Acute local toxicity was mild; as major acute side effects, only one ulceration was recorded. No severe late side effects were observed. Late toxicity was similar to that observed in our previous studies with the combination of heat and radiation. Nodal complete response was observed in 77% of patients, partial response was observed in 15% of patients and no change was observed in 8% of patients. Five-year actuarial nodal control was 64.5 ± 19% and 5-year actuarial survival was 24 ± 10%. The treatment of nodal metastases from head and neck tumours with the combination of HT and hyperfractionated XRT is feasible with an acceptable acute and late toxicity profile

  18. Concurrent platinum-based chemotherapy and hyperfractionated radiotherapy with late intensification in advanced head and neck cancer

    International Nuclear Information System (INIS)

    Glicksman, Arvin S.; Wanebo, Harold J.; Slotman, Gus; Liu Li; Landmann, Christine; Clark, Jeffrey; Zhu, Timothy C.; Lohri, Andreas; Probst, Rudolf

    1997-01-01

    Purpose: To determine whether a course of hyperfractionated radiation therapy concomitant with escalated radiosensitizing platinum compounds can be administered with acceptable morbidity and achieve a high rate of loco-regional control for Stage III and IV head and neck cancer and whether the patients can be tumor free at the primary site after initial therapy and cured by the additional chemoradiation without radical resection of the primary tumor. Methods and Materials: Patients with Stage III/IV head and neck cancer were treated in this multicenter Phase II Study with 1.8 Gy fraction radiotherapy for 2 weeks, with escalation to 1.2 Gy b.i.d. hyperfractionation to 46.8 Gy. Concomitant continuous infusion cisplatinum (CDDP) 20 mg per meter square on day 1 to 4 and 22 to 25 was given. Reassessment by biopsy of primary and nodes was done. Patients with a complete response continued with hyperfractionated radiotherapy to 75.6 Gy with simultaneous carboplatinum (Carbo), 25 mg per meter square b.i.d. for 12 consecutive treatment days. Patients with residual disease at 46.8 Gy required curative surgery. Seventy-four patients were treated at the three institutions; 20 were Stage III and 54 were Stage IV. All patients had daily mouth care, nutritional, and psychosocial support. Results: This regime was well tolerated. Eighty-five percent of toxicities were Grade 1 or 2 and there was only one Grade 4 hematologic toxicity. Late toxicities included xerostomia in 25 patients, dysplasia in 18, and mild speech impediment in 11. Biopsies of primary site were done after the first course of treatment in 59 patients. Neck dissections were performed in 35 patients. Forty-four of 59 (75%) primary sites and 16 of 35 (46%) lymph nodes had pathologically complete response (CR). Of the 74 patients, only 12 required surgical resection of the primary site. Thirty-five of the 50 node positive patients had neck dissections, 16 of these were CRs at surgery. At 4 years (median follow-up of 26

  19. A multi-institutional phase II study of hyperfractionated accelerated radiation therapy for unresectable non-small cell lung cancer: initial report of ECOG 4593

    International Nuclear Information System (INIS)

    Tannehill, Scott P.; Froseth, Carrie; Wagner, Henry; Petereit, Dan P.; Mehta, Minesh P.

    1996-01-01

    Purpose: To assess the feasibility, acute toxicity, response and survival in a trial of hyperfractionated accelerated radiation therapy for unresectable locally advanced non-small cell lung cancer (NSCLC) using a t.i.d. regimen 5 days a week in an 8 hour schedule. Materials and Methods: Thirty patients (pts) from 6 institutions were enrolled in this pilot trial. Pt characteristics: 24 male, 6 female; median age 67 yrs (range 47-84); ECOG PS 0 in 22 pts, 1 in 8 pts; weight loss >5% in 7 pts. Stage was II (inoperable) in 1 pt, IIIA in 12 pts, and IIIB in 17 pts. Radiation therapy (total 57.6 Gy/36 fx) encompassing gross disease and draining lymphatics to 36 Gy (1.5 Gy b.i.d., 8 hours apart) with daily off-cord concomitant boost to 21.6 Gy (1.8 Gy 4 hours after first fraction) was given over 12 treatment days (15 elapsed days). Results: (28(30)) (93%) pts completed radiation therapy on schedule without toxicity-related treatment interruptions. Two pts did not complete radiation therapy; 1 due to in-field progression and 1 due to fatal acute gastric bleed unrelated to therapy. Two additional pts died in the first 6 weeks: 1 due to a presumed acute cardiovascular event and another due to complications of pre-existing cardiovascular disease. The major treatment-related toxicities were esophagitis in 6 pts (18%: 5 Grade 3 and 1 Grade 4) scored using a study specific esophagitis grading tool and 2 grade 3 dermatitis, in a total of 6 pts. Only 1 pt (3%) required hospitalization for IV hydration (Grade 4 esophagitis). Median weight loss at 6 weeks was 3 kg. Response data are pending in 2 pts and unavailable in 2 due to early death. Of the remaining 26 pts, local response analysis showed CR in 4, PR in 14, stable in 7 and progressive disease in 1 for an overall response rate of (18(26)) (69%). With a median potential follow-up of 13 months, the median survival has not yet been reached. The 1-yr actuarial survival is 63%. Exclusion of the 3 pts experiencing early death (in

  20. An absorbed dose calorimeter for IMRT dosimetry

    International Nuclear Information System (INIS)

    Duane, S.; Aldehaybes, M.; Bailey, M.; Lee, N.D.; Thomas, C.G.; Palmans, H.

    2012-01-01

    A new calorimeter for dosimetry in small and complex fields has been built. The device is intended for the direct determination of absorbed dose to water in moderately small fields and in composite fields such as IMRT treatments, and as a transfer instrument calibrated against existing absorbed dose standards in conventional reference conditions. The geometry, materials and mode of operation have been chosen to minimize detector perturbations when used in a water phantom, to give a reasonably isotropic response and to minimize the effects of heat transfer when the calorimeter is used in non-reference conditions in a water phantom. The size of the core is meant to meet the needs of measurement in IMRT treatments and is comparable to the size of the air cavity in a type NE2611 ionization chamber. The calorimeter may also be used for small field dosimetry. Initial measurements in reference conditions and in an IMRT head and neck plan, collapsed to gantry angle zero, have been made to estimate the thermal characteristics of the device, and to assess its performance in use. The standard deviation (estimated repeatability) of the reference absorbed dose measurements was 0.02 Gy (0.6%). (authors)

  1. Evaluation of quality control tools for patients submitted to IMRT; Avaliacao das ferramentas de controle da qualidade para pacientes submetidos ao IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Lavor, Milton; Rodrigues, Laura N.; Silva, Marco A., E-mail: miltonlavor@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2013-04-15

    Intensity modulated radiation therapy (IMRT) is currently being implemented in a rapidly growing number of centers in Brazil. As consequence many institutions are now facing the problem of performing a comprehensive quality control program before and during the implementation of IMRT in the clinical practice. This paper proposes a methodology for quality control and presents the results and evaluations of the data obtained from the proposed methodology. Ionization chamber and two-dimensional array detector were performed in IMRT treatment planning in order to assess the absolute value of the total dose of all fields. The relative total dose distribution of all fields was measured with a radiochromic film and a two-dimensional array in a phantom. A comparison between measured and calculated dose distributions was performed using the gamma-index method, assessing the percentage of points that meet the criteria of ±3% dose difference and ±3mm distance to agreement. As a result and review of 113 tested IMRT beams using ionization chamber and 81 using two-dimensional array, the proposal was to take an action level of about ±5% compared to the treatment planning systems and measurements, for the verification of the dose in a single point at the low gradient dose region. Analysis of the two-dimensional array measurements showed that the gamma value was <1 for 97.7% of the data and for the film the gamma value was <1 for 96.6% of the data. This work can establish action levels required for quality control program proposed and implemented in the Department of Radiotherapy - Hospital das Clinicas in Sao Paulo that allows an accurate delivery of dose in 'sliding-window' IMRT with micro multi leaf collimator. (author)

  2. Automated IMRT planning in Pinnacle. A study in head-and-neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kusters, J.M.A.M.; Kollenburg, P.G.M. van; Kunze-Busch, M.C.; Wendling, M.; Dijkema, T.; Kaanders, J.H.A.M. [Radboud University Medical Center, Department of Radiation Oncology, Nijmegen (Netherlands); Bzdusek, K. [Philips Healthcare, Philips Radiation Oncology Systems, Fitchburg, WI (United States); Kumar, P. [Philips Electronics India Ltd., Philips Innovation Campus, Bangalore (India)

    2017-12-15

    This study evaluates the performance and planning efficacy of the Auto-Planning (AP) module in the clinical version of Pinnacle 9.10 (Philips Radiation Oncology Systems, Fitchburg, WI, USA). Twenty automated intensity-modulated radiotherapy (IMRT) plans were compared with the original manually planned clinical IMRT plans from patients with oropharyngeal cancer. Auto-Planning with IMRT offers similar coverage of the planning target volume as the original manually planned clinical plans, as well as better sparing of the contralateral parotid gland, contralateral submandibular gland, larynx, mandible, and brainstem. The mean dose of the contralateral parotid gland and contralateral submandibular gland could be reduced by 2.5 Gy and 1.7 Gy on average. The number of monitor units was reduced with an average of 143.9 (18%). Hands-on planning time was reduced from 1.5-3 h to less than 1 h. The Auto-Planning module was able to produce clinically acceptable head and neck IMRT plans with consistent quality. (orig.) [German] Diese Studie untersucht die Leistungsfaehigkeit und Planungseffektivitaet des Auto-Planning-Moduls in der klinischen Version von Pinnacle 9.10 (Philips Radiation Oncology Systems, Fitchburg, WI, USA). Zwanzig automatisch erstellte Plaene fuer die intensitaetsmodulierte Strahlentherapie (IMRT) wurden mit den urspruenglichen manuell erstellten klinischen IMRT-Plaenen von Patienten mit Oropharynxkarzinom verglichen. Die automatisch erstellten IMRT-Plaene bieten eine vergleichbare Deckung des Planungszielvolumens (PTV) wie die urspruenglichen, manuell erstellten klinischen Plaene sowie eine verbesserte Schonung der kontralateralen Ohrspeicheldruese, der kontralateralen Unterkieferspeicheldruese, des Kehlkopfs, des Unterkiefers und des Hirnstamms. Die mittlere Dosis der kontralateralen Ohr- und kontralateralen Unterkieferspeicheldruese konnte um durchschnittlich 2,5 bzw. 1,7 Gy reduziert werden. Die Anzahl der Monitoreinheiten wurde im Durchschnitt um 143

  3. Variable beam dose rate and DMLC IMRT to moving body anatomy

    International Nuclear Information System (INIS)

    Papiez, Lech; Abolfath, Ramin M.

    2008-01-01

    Derivation of formulas relating leaf speeds and beam dose rates for delivering planned intensity profiles to static and moving targets in dynamic multileaf collimator (DMLC) intensity modulated radiation therapy (IMRT) is presented. The analysis of equations determining algorithms for DMLC IMRT delivery under a variable beam dose rate reveals a multitude of possible delivery strategies for a given intensity map and for any given target motion patterns. From among all equivalent delivery strategies for DMLC IMRT treatments specific subclasses of strategies can be selected to provide deliveries that are particularly suitable for clinical applications providing existing delivery devices are used. Special attention is devoted to the subclass of beam dose rate variable DMLC delivery strategies to moving body anatomy that generalize existing techniques of such deliveries in Varian DMLC irradiation methodology to static body anatomy. Few examples of deliveries from this subclass of DMLC IMRT irradiations are investigated to illustrate the principle and show practical benefits of proposed techniques.

  4. Variable beam dose rate and DMLC IMRT to moving body anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Papiez, Lech; Abolfath, Ramin M. [Department of Radiation Oncology, UTSouthwestern Medical Center, Dallas, Texas 75390 (United States)

    2008-11-15

    Derivation of formulas relating leaf speeds and beam dose rates for delivering planned intensity profiles to static and moving targets in dynamic multileaf collimator (DMLC) intensity modulated radiation therapy (IMRT) is presented. The analysis of equations determining algorithms for DMLC IMRT delivery under a variable beam dose rate reveals a multitude of possible delivery strategies for a given intensity map and for any given target motion patterns. From among all equivalent delivery strategies for DMLC IMRT treatments specific subclasses of strategies can be selected to provide deliveries that are particularly suitable for clinical applications providing existing delivery devices are used. Special attention is devoted to the subclass of beam dose rate variable DMLC delivery strategies to moving body anatomy that generalize existing techniques of such deliveries in Varian DMLC irradiation methodology to static body anatomy. Few examples of deliveries from this subclass of DMLC IMRT irradiations are investigated to illustrate the principle and show practical benefits of proposed techniques.

  5. SU-E-T-256: Development of a Monte Carlo-Based Dose-Calculation System in a Cloud Environment for IMRT and VMAT Dosimetric Verification

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Y [Tokai University School of Medicine, Isehara, Kanagawa (Japan)

    2015-06-15

    Purpose: Intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are techniques that are widely used for treating cancer due to better target coverage and critical structure sparing. The increasing complexity of IMRT and VMAT plans leads to decreases in dose calculation accuracy. Monte Carlo simulations are the most accurate method for the determination of dose distributions in patients. However, the simulation settings for modeling an accurate treatment head are very complex and time consuming. The purpose of this work is to report our implementation of a simple Monte Carlo simulation system in a cloud-computing environment for dosimetric verification of IMRT and VMAT plans. Methods: Monte Carlo simulations of a Varian Clinac linear accelerator were performed using the BEAMnrc code, and dose distributions were calculated using the DOSXYZnrc code. Input files for the simulations were automatically generated from DICOM RT files by the developed web application. We therefore must only upload the DICOM RT files through the web interface, and the simulations are run in the cloud. The calculated dose distributions were exported to RT Dose files that can be downloaded through the web interface. The accuracy of the calculated dose distribution was verified by dose measurements. Results: IMRT and VMAT simulations were performed and good agreement results were observed for measured and MC dose comparison. Gamma analysis with a 3% dose and 3 mm DTA criteria shows a mean gamma index value of 95% for the studied cases. Conclusion: A Monte Carlo-based dose calculation system has been successfully implemented in a cloud environment. The developed system can be used for independent dose verification of IMRT and VMAT plans in routine clinical practice. The system will also be helpful for improving accuracy in beam modeling and dose calculation in treatment planning systems. This work was supported by JSPS KAKENHI Grant Number 25861057.

  6. SU-E-T-256: Development of a Monte Carlo-Based Dose-Calculation System in a Cloud Environment for IMRT and VMAT Dosimetric Verification

    International Nuclear Information System (INIS)

    Fujita, Y

    2015-01-01

    Purpose: Intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are techniques that are widely used for treating cancer due to better target coverage and critical structure sparing. The increasing complexity of IMRT and VMAT plans leads to decreases in dose calculation accuracy. Monte Carlo simulations are the most accurate method for the determination of dose distributions in patients. However, the simulation settings for modeling an accurate treatment head are very complex and time consuming. The purpose of this work is to report our implementation of a simple Monte Carlo simulation system in a cloud-computing environment for dosimetric verification of IMRT and VMAT plans. Methods: Monte Carlo simulations of a Varian Clinac linear accelerator were performed using the BEAMnrc code, and dose distributions were calculated using the DOSXYZnrc code. Input files for the simulations were automatically generated from DICOM RT files by the developed web application. We therefore must only upload the DICOM RT files through the web interface, and the simulations are run in the cloud. The calculated dose distributions were exported to RT Dose files that can be downloaded through the web interface. The accuracy of the calculated dose distribution was verified by dose measurements. Results: IMRT and VMAT simulations were performed and good agreement results were observed for measured and MC dose comparison. Gamma analysis with a 3% dose and 3 mm DTA criteria shows a mean gamma index value of 95% for the studied cases. Conclusion: A Monte Carlo-based dose calculation system has been successfully implemented in a cloud environment. The developed system can be used for independent dose verification of IMRT and VMAT plans in routine clinical practice. The system will also be helpful for improving accuracy in beam modeling and dose calculation in treatment planning systems. This work was supported by JSPS KAKENHI Grant Number 25861057

  7. Peripheral doses of cranial pediatric IMRT performed with attenuator blocks

    International Nuclear Information System (INIS)

    Soboll, Danyel Scheidegger; Schitz, Ivette; Schelin, Hugo Reuters; Silva, Ricardo Goulart da; Viamonte, Alfredo

    2011-01-01

    This paper presents values of peripheral doses measured at six vital points of simulator objects which represent the ages of 2, 5 and 10 years old, submitted to a cranial IMRT procedure that applied compensator blocks interposed to 6 MV beams. The found values indicate that there is independence of dose with position of measurements and age of the patient, as the peripheral dose at the points nearest and the 2 year old simulator object where larger. The doses in thyroid reached the range of 1.4 to 2.9% of the dose prescribed in the isocenter, indicating that the peripheral doses for IMRT that employ compensator blocks can be greater than for the IMRT produced with sliding window technique

  8. Radiotherapy through intensity modulation (IMRT). A new modality in the treatment of head and neck cancer

    International Nuclear Information System (INIS)

    Besa de C, Pelayo; Venencia M, Daniel

    2006-01-01

    Objective: To describe the treatment and evaluate the advantages of IMRT in the treatment of head and neck cancer. Material and methods: Four years ago, at the Cancer Center of the Pontificia Universidad Catolica, the IMRT technique for the treatment of head and neck tumors was implemented. The IMRT technique is based on modifying the intensity of the radiation beam through a multisheet collimator in order to produce a more exact distribution in the radiation doses. The results are evaluated with dose/ volume histograms. The distributions of doses and toxicity for tridimensional con formed therapy (CRT-3D) and IMRT are compared. Results: The distribution of the dose in the dose/volume histograms showed a better coverage of the white volume (PTV), with IMRT. The doses received by the organs under risk: salivary glands, eyes, ears and brain diminish with IMRT. The spinal marrow is protected with IMRT without dividing the treatment area, preventing points with lower dosage that could reduce control of the tumor. Conclusions: IMRT achieves a better conformation of the dose obtaining a better coverage of the tumor and higher protection of the organs under risk

  9. Automatic learning-based beam angle selection for thoracic IMRT

    International Nuclear Information System (INIS)

    Amit, Guy; Marshall, Andrea; Purdie, Thomas G.; Jaffray, David A.; Levinshtein, Alex; Hope, Andrew J.; Lindsay, Patricia; Pekar, Vladimir

    2015-01-01

    Purpose: The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process, which requires the planner to iterate between choosing beam angles, specifying dose–volume objectives and executing IMRT optimization. In thorax treatment planning, where there are no class solutions for beam placement, beam angle selection is performed manually, based on the planner’s clinical experience. The purpose of this work is to propose and study a computationally efficient framework that utilizes machine learning to automatically select treatment beam angles. Such a framework may be helpful for reducing the overall planning workload. Methods: The authors introduce an automated beam selection method, based on learning the relationships between beam angles and anatomical features. Using a large set of clinically approved IMRT plans, a random forest regression algorithm is trained to map a multitude of anatomical features into an individual beam score. An optimization scheme is then built to select and adjust the beam angles, considering the learned interbeam dependencies. The validity and quality of the automatically selected beams evaluated using the manually selected beams from the corresponding clinical plans as the ground truth. Results: The analysis included 149 clinically approved thoracic IMRT plans. For a randomly selected test subset of 27 plans, IMRT plans were generated using automatically selected beams and compared to the clinical plans. The comparison of the predicted and the clinical beam angles demonstrated a good average correspondence between the two (angular distance 16.8° ± 10°, correlation 0.75 ± 0.2). The dose distributions of the semiautomatic and clinical plans were equivalent in terms of primary target volume

  10. IMRT QA using machine learning: A multi-institutional validation.

    Science.gov (United States)

    Valdes, Gilmer; Chan, Maria F; Lim, Seng Boh; Scheuermann, Ryan; Deasy, Joseph O; Solberg, Timothy D

    2017-09-01

    To validate a machine learning approach to Virtual intensity-modulated radiation therapy (IMRT) quality assurance (QA) for accurately predicting gamma passing rates using different measurement approaches at different institutions. A Virtual IMRT QA framework was previously developed using a machine learning algorithm based on 498 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3 mm with 10% threshold at Institution 1. An independent set of 139 IMRT measurements from a different institution, Institution 2, with QA data based on portal dosimetry using the same gamma index, was used to test the mathematical framework. Only pixels with ≥10% of the maximum calibrated units (CU) or dose were included in the comparison. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. The methodology predicted passing rates within 3% accuracy for all composite plans measured using diode-array detectors at Institution 1, and within 3.5% for 120 of 139 plans using portal dosimetry measurements performed on a per-beam basis at Institution 2. The remaining measurements (19) had large areas of low CU, where portal dosimetry has a larger disagreement with the calculated dose and as such, the failure was expected. These beams need further modeling in the treatment planning system to correct the under-response in low-dose regions. Important features selected by Lasso to predict gamma passing rates were as follows: complete irradiated area outline (CIAO), jaw position, fraction of MLC leafs with gaps smaller than 20 or 5 mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted average irregularity factor, and duty cycle. We have demonstrated that Virtual IMRT QA can predict passing rates using different measurement techniques and across multiple

  11. Health-Related Quality-of-Life Outcomes Following IMRT Versus Conventional Radiotherapy for Oropharyngeal Squamous Cell Carcinoma

    International Nuclear Information System (INIS)

    Yao Min; Karnell, Lucy H.; Funk, Gerry F.; Lu Heming; Dornfeld, Ken; Buatti, John M.

    2007-01-01

    Purpose: To compare health-related quality-of-life (HRQOL) outcomes of patients with oropharyngeal squamous cell carcinoma treated using intensity-modulated radiotherapy (IMRT) vs. conventional radiotherapy (CRT). Patients and Methods: Patients with oropharyngeal squamous cell carcinoma were extracted from the database of an ongoing longitudinal Outcome Assessment Project. Eligible criteria included (1) treated with definitive radiation, and (2) provided 12-month posttreatment HRQOL data. Excluded were 7 patients who received IMRT before October 1, 2002, during this institution's developmental phase of the IMRT technique. The HRQOL outcomes of patients treated with IMRT were compared with those of patients who received CRT. Results: Twenty-six patients treated using IMRT and 27 patients treated using CRT were included. Patients in the IMRT group were older and had more advanced-stage diseases and more patients received concurrent chemotherapy. However, the IMRT group had higher mean Head and Neck Cancer Inventory scores (which represent better outcomes) for each of the four head-and-neck cancer-specific domains, including eating, speech, aesthetics, and social disruption, at 12 months after treatment. A significantly greater percentage of patients in the CRT group had restricted diets compared with those in the IMRT group (48.0% vs. 16.0%, p = 0.032). At 3 months after treatment, both groups had significant decreases from pretreatment eating scores. However, the IMRT group had a significant improvement during the first year, but the CRT group had only small improvement. Conclusions: Proper delivery of IMRT can improve HRQOL for patients with oropharyngeal cancer compared with CRT

  12. Locoregionally advanced carcinoma of the oropharynx: conventional radiotherapy vs. accelerated hyperfractionated radiotherapy vs. concomitant radiotherapy and chemotherapy - a multicenter randomized trial

    International Nuclear Information System (INIS)

    Olmi, Patrizia; Crispino, Sergio; Fallai, Carlo; Torri, Valter; Rossi, Francesca; Bolner, Andrea; Amichetti, Maurizio; Signor, Marco; Taino, Raffaella; Squadrelli, Massimo; Colombo, Alessandro; Ardizzoia, Alessandro; Ponticelli, Pietro; Franchin, Giovanni; Minatel, Emilio; Gobitti, Carlo; Atzeni, Guido; Gava, Alessandro; Flann, Monica; Marsoni, Silvia

    2003-01-01

    Purpose: To compare conventional fractionation radiation therapy (RT), Arm A, vs. split-course accelerated hyperfractionated RT (S-AHF), Arm B, vs. conventional fractionation RT plus concomitant chemotherapy (CT), Arm C, in terms of survival and toxicity for advanced, unresectable epidermoid tumors of oropharynx. Methods and Materials: Between January 1993 and June 1998, 192 previously untreated patients affected with Stage III and IV oropharyngeal carcinoma (excluding T1N1 and T2N1) were accrued in a multicenter, randomized Phase III trial (ORO 93-01). For Arms A and C, 66-70 Gy in 33-35 fractions, 5 days a week, were administered in 6.5-7 weeks to tumor and positive nodes. In Arm B, the dose delivered to tumor and involved nodes was 64-67.2 Gy, giving 2 fractions of 1.6 Gy every day with an interfraction interval of at least 4 h and preferably 6 h, 5 days a week. At 38.4 Gy, a 2-week split was planned; after the split, RT was resumed with the same modality. In Arm C, CT regimen consisted of carboplatin and 5-fluorouracil (CBDCA 75 mg/m 2 , Days 1-4; 5-FU 1,000 mg/m 2 i.v. over 96 h, Days 1-4, recycling every 28 days (at 1st, 5th, and 9th week). Results: No statistically significant difference was detected in overall survival (p=0.129): 40% Arm A vs. 37% Arm B vs. 51% Arm C were alive at 24 months. Similarly, there was no statistically significant difference in terms of event-free survival (p=0.196): 20% for Arm A, 19% for Arm B, and 37% for Arm C were event free at 24 months. On the contrary, the 2-year disease-free survival was significantly different among the three arms (p = 0.022), with a superiority for Arm C. At 24 months, the proportion of patients without relapse was 42% for Arm C vs. 23% for Arm A and 20% for Arm B. Patients in Arm A less frequently developed G3+ acute mucositis than their counterparts in Arm B or C (14.7% vs. 40.3% vs. 44%). Regarding the CT-related acute toxicity, apart from 1 case of fatal nephrotoxicity, only hematologic G3+ (Grade 3

  13. Superior sulcus non-small cell lung carcinoma: A comparison of IMRT and 3D-RT dosimetry.

    Science.gov (United States)

    Truntzer, Pierre; Antoni, Delphine; Santelmo, Nicola; Schumacher, Catherine; Falcoz, Pierre-Emmanuel; Quoix, Elisabeth; Massard, Gilbert; Noël, Georges

    2016-01-01

    A dosimetric study comparing intensity modulated radiotherapy (IMRT) by TomoTherapy to conformational 3D radiotherapy (3D-RT) in patients with superior sulcus non-small cell lung cancer (NSCLC). IMRT became the main technique in modern radiotherapy. However it was not currently used for lung cancers. Because of the need to increase the dose to control lung cancers but because of the critical organs surrounding the tumors, the gains obtainable with IMRT is not still demonstrated. A dosimetric comparison of the planned target and organs at risk parameters between IMRT and 3D-RT in eight patients who received preoperative or curative intent irradiation. In the patients who received at least 66 Gy, the mean V95% was significantly better with IMRT than 3D-RT (p = 0.043). IMRT delivered a lower D2% compared to 3D-RT (p = 0.043). The IH was significantly better with IMRT (p = 0.043). The lung V 5 Gy and V 13 Gy were significantly higher in IMRT than 3D-RT (p = 0.043), while the maximal dose (D max) to the spinal cord was significantly lower in IMRT (p = 0.043). The brachial plexus D max was significantly lower in IMRT than 3D-RT (p = 0.048). For patients treated with 46 Gy, no significant differences were found. Our study showed that IMRT is relevant for SS-NSCLC. In patients treated with a curative dose, it led to a reduction of the exposure of critical organs, allowing a better dose distribution in the tumor. For the patients treated with a preoperative schedule, our results provide a basis for future controlled trials to improve the histological complete response by increasing the radiation dose.

  14. A fast dose calculation method based on table lookup for IMRT optimization

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Lauterbach, Marc; Wu Yan; Mohan, Radhe

    2003-01-01

    This note describes a fast dose calculation method that can be used to speed up the optimization process in intensity-modulated radiotherapy (IMRT). Most iterative optimization algorithms in IMRT require a large number of dose calculations to achieve convergence and therefore the total amount of time needed for the IMRT planning can be substantially reduced by using a faster dose calculation method. The method that is described in this note relies on an accurate dose calculation engine that is used to calculate an approximate dose kernel for each beam used in the treatment plan. Once the kernel is computed and saved, subsequent dose calculations can be done rapidly by looking up this kernel. Inaccuracies due to the approximate nature of the kernel in this method can be reduced by performing scheduled kernel updates. This fast dose calculation method can be performed more than two orders of magnitude faster than the typical superposition/convolution methods and therefore is suitable for applications in which speed is critical, e.g., in an IMRT optimization that requires a simulated annealing optimization algorithm or in a practical IMRT beam-angle optimization system. (note)

  15. The number of beams in IMRT-theoretical investigations and implications for single-arc IMRT

    International Nuclear Information System (INIS)

    Bortfeld, Thomas

    2010-01-01

    The first purpose of this paper is to shed some new light on the old question of selecting the number of beams in intensity-modulated radiation therapy (IMRT). The second purpose is to illuminate the related issue of discrete static beam angles versus rotational techniques, which has recently re-surfaced due to the advancement of volumetric modulated arc therapy (VMAT). A specific objective is to find analytical expressions that allow one to address the points raised above. To make the problem mathematically tractable, it is assumed that the depth dose is flat and that the lateral dose profile can be approximated by polynomials, specifically Chebyshev polynomials of the first kind, of finite degree. The application of methods known from image reconstruction then allows one to answer the first question above as follows: the required number of beams is determined by the maximum degree of the polynomials used in the approximation of the beam profiles, which is a measure of the dose variability. There is nothing to be gained by using more beams. In realistic cases, in which the variability of the lateral dose profile is restricted in several ways, the required number of beams is of the order of 10-20. The consequence of delivering the beams with a 'leaf sweep' technique during continuous rotation of the gantry, as in VMAT, is also derived in an analytical form. The main effect is that the beams fan out, but the effect near the axis of rotation is small. This result can serve as a theoretical justification of VMAT. Overall the analytical derivations in this paper, albeit based on strong simplifications, provide new insights into, and a deeper understanding of, the beam angle problem in IMRT. The decomposition of the beam profiles into well-behaved and easily deliverable smooth functions, such as Chebyshev polynomials, could be of general interest in IMRT treatment planning.

  16. Risk profile for osteoradionecrosis of the mandible in the IMRT era

    Energy Technology Data Exchange (ETDEWEB)

    Studer, Gabriela; Glanzmann, Christoph [University Hospital Zurich, Department of Radiation Oncology, Head Neck Cancer Center, Zurich (Switzerland); Bredell, Marius; Studer, Stephan [University Hospital Zurich, Department of Craniomaxillofacial and Oral Surgery, Head Neck Cancer Center, Zurich (Switzerland); Huber, Gerhard [University Hospital Zurich, Department of Otorhinolaryngology, Head Neck Cancer Center, Head and Neck Surgery, Zurich (Switzerland)

    2016-01-15

    The risk for osteoradionecrosis (ORN) of the mandible is positively related to bone volume exposed to >∝ 60 Gy. We hypothesized that in combined treatment, surgery may also be a risk factor. The impact of mandibular surgery on ORN in locally disease-free IMRT cohorts was retrospectively analyzed. Between October 2002 and October 2013, 531 of 715 patients with oral cavity cancer (OCC), mesopharyngeal cancer (MC), or salivary gland tumor were treated with the mandible bone exposed to ∝> 60 Gy (mean follow-up, 38 months; 7-143 months). Of the 531 patients, 36 developed ORN (7 %; 1.5 % with grade 3-4). The ORN rate in definitive IMRT MC (16/227) and in postoperative IMRT OCC patients with no mandibular surgery (3/46) was 7 % each; in OCC patients with mandibular surgery the rate was 29 % (15/60, p = 0.002). Marginal or periosteal bone resection was found to be a high risk factor (39 %, vs. 7 % followed by segmental or no resection, p < 0.0001). Marginal or periosteal bone resection of the mandible was identified as the highest ORN risk factor in our IMRT cohort. (orig.) [German] Das Risiko fuer die Entwicklung einer Kiefernekrose nach Radiotherapie (Osteoradionekrose, ORN) korreliert bekanntlich mit dem Knochenvolumen, das einer Dosis von ∝> 60 Gy ausgesetzt wurde. Hypothese war, dass die Chirurgie bei kombinierten Therapien ebenfalls einen Risikofaktor darstellt. Der Einfluss chirurgischer Interventionen am Kiefer auf das Risiko einer ORN wurde in unserem lokal krankheitsfreien IMRT-Kollektiv retrospektiv analysiert. Zwischen Oktober 2002 und Oktober 2013 wurden 531/715 Patienten mit Mundhoehlenkarzinomen (OCC), Mesopharynxkarzinomen (MC) oder Speicheldruesentumoren mit Dosen > 60 Gy am Kieferknochen behandelt (mittlere Beobachtungszeit 38 Monate; Spanne 7-143 Monate). Von 531 Patienten entwickelten 36 eine ORN (7 %; 1,5 % mit Grad 3-4). Die ORN-Rate nach definitiver IMRT bei MC (16/227) und nach postoperativer IMRT bei OCC ohne chirurgischen Eingriff am

  17. Hyperfractionated total body irradiation for bone marrow transplantation. Results in seventy leukemia patients with allogeneic transplants

    International Nuclear Information System (INIS)

    Shank, B.; Chu, F.C.H.; Dinsmore, R.

    1983-01-01

    From May, 1979 to March, 1981, 76 leukemia patients were prepared for bone marrow transplantation (BMT) with a new hyperfractionated total body irradiation (TBI) regimen (1320 cGy in 11 fractions, 3x/day), followed by cyclophosphamide, 60 mg/kg, for two days. Partial lung shielding was done on each treatment, with supplemental electron beam treatments of the chest wall to compensate, and of the testes, a sanctuary site. This regimen was initiated to potentially reduce fatal interstitial pneumonitis as well as decrease leukemic relapse. Overall actuarial survival at 1 year for acute non-lymphocytic leukemia (ANLL) patients is 63%, while relapse-free survival at 1 year is 53%. On the other hand, for acute lymphocytic leukemia (ALL) patients, there is no significant difference between relapse or remission patients with regard to overall survival or relapse-free survival, when relapse is defined as > 5% blasts in the marrow at the time of cytoreduction. Overall actuarial survival at 1 year for ALL is 61% and relapse-free survival is 45% at 1 year. Fatal interstitial pneumonitis has dropped to 18% compared with 50% in our previous single-dose TBI regimen (1000 cGy), in which the same doses of cyclophosphamide were given prior to TBI. In conclusion, not only has fatal interstitial pneumonitis been reduced by hyperfractionation and partial lung blocking, but there may be a survival advantage in ALL patients in relapse, who have a survival equal to that of remission patients. This may indicate a greater cell kill with the higher dose (1320 cGy) attained with this regimen, in these patients with a higher leukemic cell burden

  18. Quantification of Prostate and Seminal Vesicle Interfraction Variation During IMRT

    International Nuclear Information System (INIS)

    Frank, Steven J.; Dong Lei; Kudchadker, Rajat J.; De Crevoisier, Renaud; Lee, Andrew K.; Cheung, Rex; Choi, Seungtaek; O'Daniel, Jennifer; Tucker, Susan L.; Wang He; Kuban, Deborah A.

    2008-01-01

    Purpose: To quantify the interfraction variability in prostate and seminal vesicle (SV) positions during a course of intensity-modulated radiotherapy (IMRT) using an integrated computed tomography (CT)-linear accelerator system and to assess the impact of rectal and bladder volume changes. Methods and Materials: We studied 15 patients who had undergone IMRT for prostate carcinoma. Patients had one pretreatment planning CT scan followed by three in-room CT scans per week using a CT-on-rails system. The prostate, bladder, rectum, and pelvic bony anatomy were contoured in 369 CT scans. Using the planning CT scan as a reference, the volumetric and positional changes were analyzed in the subsequent CT scans. Results: For all 15 patients, the mean systematic internal prostate and SV variation was 0.1 ± 4.1 mm and 1.2 ± 7.3 mm in the anteroposterior axis, -0.5 ± 2.9 mm and -0.7 ± 4.5 mm in the superoinferior axis, and 0.2 ± 0.9 mm and -0.9 ± 1.9 mm in the lateral axis, respectively. The mean magnitude of the three-dimensional displacement vector was 4.6 ± 3.5 mm for the prostate and 7.6 ± 4.7 mm for the SVs. The rectal and bladder volume changes during treatment correlated with the anterior and superior displacement of the prostate and SVs. Conclusion: The dominant prostate and SV variations occurred in the anteroposterior and superoinferior directions. The systematic prostate and SV variation between the treatment planning CT and daily therapy as a result of the rectal and bladder volume changes emphasizes the need for daily directed target localization and/or immobilization techniques

  19. Intensity-modulated radiation therapy (IMRT) of cancers of the head and neck: Comparison of split-field and whole-field techniques

    International Nuclear Information System (INIS)

    Dabaja, Bouthaina; Salehpour, Mohammad R.; Rosen, Isaac; Tung, Sam; Morrison, William H.; Ang, K. Kian; Garden, Adam S.

    2005-01-01

    Background: Oropharynx cancers treated with intensity-modulated radiation (IMRT) are often treated with a monoisocentric or half-beam technique (HB). IMRT is delivered to the primary tumor and upper neck alone, while the lower neck is treated with a matching anterior beam. Because IMRT can treat the entire volume or whole field (WF), the primary aim of the study was to test the ability to plan cases using WF-IMRT while obtaining an optimal plan and acceptable dose distribution and also respecting normal critical structures. Methods and Materials: Thirteen patients with early-stage oropharynx cancers had treatment plans created with HB-IMRT and WF-IMRT techniques. Plans were deemed acceptable if they met the planning guidelines (as defined or with minor violations) of the Radiation Therapy Oncology Group protocol H0022. Comparisons included coverage to the planning target volume (PTV) of the primary (PTV66) and subclinical disease (PTV54). We also compared the ability of both techniques to respect the tolerance of critical structures. Results: The volume of PTV66 treated to >110% was less in 9 of the 13 patients in the WF-IMRT plan as compared to the HB-IMRT plan. The calculated mean volume receiving >110% for all patients planned with WF-IMRT was 9.3% (0.8%-25%) compared to 13.7% (2.7%-23.7%) with HB-IMRT (p = 0.09). The PTV54 volume receiving >110% of dose was less in 10 of the 13 patients planned with WF-IMRT compared to HB-IMRT. The mean doses to all critical structures except the larynx were comparable with each plan. The mean dose to the larynx was significantly less (p = 0.001), 18.7 Gy, with HB-IMRT compared to 47 Gy with WF-IMRT. Conclusions: Regarding target volumes, acceptable plans can be generated with either WF-IMRT or HB-IMRT. WF-IMRT has an advantage if uncertainty at the match line is a concern, whereas HB-IMRT, particularly in cases not involving the base of tongue, can achieve much lower doses to the larynx

  20. Evaluation tools of quality control for patients submitted to IMRT

    International Nuclear Information System (INIS)

    Lavor, Milton

    2011-01-01

    Intensity modulated radiation therapy (IMRT) is currently been implemented in a rapidly growing number of centers in Brazil. As consequence many institutions are now facing the problem of performing a comprehensive quality control program before and during the implementation of IMRT in the clinical routine practice. The aim of this work is to evaluate and propose a methodology for quality assurance in IMRT treatments. An ionization chamber and a two-dimensional array detector were performed to assess the absolute value of the total dose of all fields in one specific point. The relative total dose distribution of all fields was measured with a radiochromic film and a two-dimensional array at one depth in a phantom. A comparison between measured and calculated dose distributions was performed using the gamma-index method, assessing the percentage of points that meet the criteria of +-3% dose difference and +-3 mm distance to agreement. As a result of 113 tested IMRT beams using ionization chamber and 81 using two-dimensional array, the proposal was to take an action level of about +- 5% compared to the treatment planning systems and measurements, for the verification of the dose in a single point at the low gradient dose region. Analysis of the two-dimensional array measurements showed that the gamma value was <1 for 97.7% of the data and for the film the gamma value was <1 for 96.6% of the data. This can be concluded that for an accurate delivery of dose in 'sliding-window' IMRT with micro multileaf collimator, the absolute value of the total dose and the relative total dose distribution should be checked by absolute and relative dosimetry respectively. (author)

  1. Development of an IMRT quality assurance program using an amorphous silicon electronic portal imaging device

    International Nuclear Information System (INIS)

    Hunt, P.; Oliver, L.; Mallik, A.

    2000-01-01

    Full text: Quality Assurance (QA) for an intensity modulated radiotherapy (IMRT) megavoltage beam is a complex task. The positional accuracy of the MLC; its radiation leakage; the overall distribution of the dose delivered as compared to the treatment plan and; the accuracy of the calculated monitor units to deliver this dose, are all important parameters to clinically monitor. We are presently assessing the Varian version 6 software package with CadPlan, Helios with IMRT and inverse planning, VARiS Vision and the linear accelerator DMLC controller. Whilst conventional QA tools such as ionisation chamber and film measurements are used, these methods are inconvenient for directly monitoring an IMRT patient treatment. Varian Medical Systems has developed an improved electronic portal imaging device (EPID) with an amorphous silicon (a-Si) detector array. The A-Si has a sensitive area of 40x30cm and an improved image resolution of 512x384 pixels. Images are recorded at approximately 7-10 frames per second for an exposure rate of 100-600 MU/minute. Although the A-Si was designed as an EPID for a static treatment field, this new device could be a valuable IMRT QA tool for a range of different tests. Measurements taken on the RNSH and Varian prototype A-Si EPI devices showed a linear dose response for 6-18MeV X-ray energy. In addition to the Varian IAS2 internal software handlers, we have developed some image data handling programs to view and analyse these images in more detail. The software is primarily used to view the images; measure the reading in a region of interest or profile; or merge, overlay, add or subtract images during the analysis. The small pixel resolution provides a reliable, highly accurate means of measuring beam size, leaf position, MLC radiation leakage or profile intensity curves with a positional accuracy of 0.8mm. The images produced by an IMRT exposure is clearly discernible and appears consistent with the result expected. Step wedge images

  2. Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    Science.gov (United States)

    Miften, Moyed; Olch, Arthur; Mihailidis, Dimitris; Moran, Jean; Pawlicki, Todd; Molineu, Andrea; Li, Harold; Wijesooriya, Krishni; Shi, Jie; Xia, Ping; Papanikolaou, Nikos; Low, Daniel A

    2018-04-01

    Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review aimed at improving the understanding and consistency of these processes as well as recommendations for methodologies and tolerance limits in patient-specific IMRT QA. The performance of the dose difference/distance-to-agreement (DTA) and γ dose distribution comparison metrics are investigated. Measurement methods are reviewed and followed by a discussion of the pros and cons of each. Methodologies for absolute dose verification are discussed and new IMRT QA verification tools are presented. Literature on the expected or achievable agreement between measurements and calculations for different types of planning and delivery systems are reviewed and analyzed. Tests of vendor implementations of the γ verification algorithm employing benchmark cases are presented. Operational shortcomings that can reduce the γ tool accuracy and subsequent effectiveness for IMRT QA are described. Practical considerations including spatial resolution, normalization, dose threshold, and data interpretation are discussed. Published data on IMRT QA and the clinical experience of the group members are used to develop guidelines and recommendations on tolerance and action limits for IMRT QA. Steps to check failed IMRT QA plans are outlined. Recommendations on delivery methods, data interpretation, dose normalization, the use of γ analysis routines and choice of tolerance limits for IMRT QA are made with focus on detecting differences between calculated and measured doses via the use of robust analysis methods and an in-depth understanding of IMRT verification metrics. The recommendations are intended to improve the IMRT QA process and establish consistent, and comparable IMRT QA

  3. Parotid gland sparing IMRT for head and neck cancer improves xerostomia related quality of life

    International Nuclear Information System (INIS)

    Rij, CM van; Oughlane-Heemsbergen, WD; Ackerstaff, AH; Lamers, EA; Balm, AJM; Rasch, CRN

    2008-01-01

    To assess the impact of intensity modulated radiotherapy (IMRT) versus conventional radiation on late xerostomia and Quality of Life aspects in head and neck cancer patients. Questionnaires on xerostomia in rest and during meals were sent to all patients treated between January 1999 and December 2003 with a T1-4, N0-2 M0 head and neck cancer, with parotid gland sparing IMRT or conventional bilateral neck irradiation to a dose of at least 60 Gy, who were progression free and had no disseminated disease (n = 192). Overall response was 85% (n = 163); 97% in the IMRT group (n = 75) and 77% in the control group (n = 88) the median follow-up was 2.6 years. The prevalence of complaints was compared between the two groups, correcting for all relevant factors at multivariate ordinal regression analysis. Patients treated with IMRT reported significantly less difficulty transporting and swallowing their food and needed less water for a dry mouth during day, night and meals. They also experienced fewer problems with speech and eating in public. Laryngeal cancer patients in general had fewer complaints than oropharynx cancer patients but both groups benefited from IMRT. Within the IMRT group the xerostomia scores were better for those patients with a mean parotid dose to the 'spared' parotid below 26 Gy. Parotid gland sparing IMRT for head and neck cancer patients improves xerostomia related quality of life compared to conventional radiation both in rest and during meals. Laryngeal cancer patients had fewer complaints but benefited equally compared to oropharyngeal cancer patients from IMRT

  4. Incorporating prior knowledge into beam orientation optimization in IMRT

    International Nuclear Information System (INIS)

    Pugachev, Andrei M.S.; Lei Xing

    2002-01-01

    Purpose: Selection of beam configuration in currently available intensity-modulated radiotherapy (IMRT) treatment planning systems is still based on trial-and-error search. Computer beam orientation optimization has the potential to improve the situation, but its practical implementation is hindered by the excessive computing time associated with the calculation. The purpose of this work is to provide an effective means to speed up the beam orientation optimization by incorporating a priori geometric and dosimetric knowledge of the system and to demonstrate the utility of the new algorithm for beam placement in IMRT. Methods and Materials: Beam orientation optimization was performed in two steps. First, the quality of each possible beam orientation was evaluated using beam's-eye-view dosimetrics (BEVD) developed in our previous study. A simulated annealing algorithm was then employed to search for the optimal set of beam orientations, taking into account the BEVD scores of different incident beam directions. During the calculation, sampling of gantry angles was weighted according to the BEVD score computed before the optimization. A beam direction with a higher BEVD score had a higher probability of being included in the trial configuration, and vice versa. The inclusion of the BEVD weighting in the stochastic beam angle sampling process made it possible to avoid spending valuable computing time unnecessarily at 'bad' beam angles. An iterative inverse treatment planning algorithm was used for beam intensity profile optimization during the optimization process. The BEVD-guided beam orientation optimization was applied to an IMRT treatment of paraspinal tumor. The advantage of the new optimization algorithm was demonstrated by comparing the calculation with the conventional scheme without the BEVD weighting in the beam sampling. Results: The BEVD tool provided useful guidance for the selection of the potentially good directions for the beams to incident and was used

  5. Automated IMRT planning in Pinnacle. A study in head-and-neck cancer

    International Nuclear Information System (INIS)

    Kusters, J.M.A.M.; Kollenburg, P.G.M. van; Kunze-Busch, M.C.; Wendling, M.; Dijkema, T.; Kaanders, J.H.A.M.; Bzdusek, K.; Kumar, P.

    2017-01-01

    This study evaluates the performance and planning efficacy of the Auto-Planning (AP) module in the clinical version of Pinnacle 9.10 (Philips Radiation Oncology Systems, Fitchburg, WI, USA). Twenty automated intensity-modulated radiotherapy (IMRT) plans were compared with the original manually planned clinical IMRT plans from patients with oropharyngeal cancer. Auto-Planning with IMRT offers similar coverage of the planning target volume as the original manually planned clinical plans, as well as better sparing of the contralateral parotid gland, contralateral submandibular gland, larynx, mandible, and brainstem. The mean dose of the contralateral parotid gland and contralateral submandibular gland could be reduced by 2.5 Gy and 1.7 Gy on average. The number of monitor units was reduced with an average of 143.9 (18%). Hands-on planning time was reduced from 1.5-3 h to less than 1 h. The Auto-Planning module was able to produce clinically acceptable head and neck IMRT plans with consistent quality. (orig.) [de

  6. Automated IMRT planning in Pinnacle : A study in head-and-neck cancer.

    Science.gov (United States)

    Kusters, J M A M; Bzdusek, K; Kumar, P; van Kollenburg, P G M; Kunze-Busch, M C; Wendling, M; Dijkema, T; Kaanders, J H A M

    2017-12-01

    This study evaluates the performance and planning efficacy of the Auto-Planning (AP) module in the clinical version of Pinnacle 9.10 (Philips Radiation Oncology Systems, Fitchburg, WI, USA). Twenty automated intensity-modulated radiotherapy (IMRT) plans were compared with the original manually planned clinical IMRT plans from patients with oropharyngeal cancer. Auto-Planning with IMRT offers similar coverage of the planning target volume as the original manually planned clinical plans, as well as better sparing of the contralateral parotid gland, contralateral submandibular gland, larynx, mandible, and brainstem. The mean dose of the contralateral parotid gland and contralateral submandibular gland could be reduced by 2.5 Gy and 1.7 Gy on average. The number of monitor units was reduced with an average of 143.9 (18%). Hands-on planning time was reduced from 1.5-3 h to less than 1 h. The Auto-Planning module was able to produce clinically acceptable head and neck IMRT plans with consistent quality.

  7. Dosimetric comparison of RapidArc with fixed gantry dynamic IMRT for loco-regionally advanced nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Wu Hao; Han Shukui; Sun Yan; Jiang Fan

    2010-01-01

    Objective: To compare the dosimetric difference of RapidArc and fixed gantry angle dynamic IMRT (dIMRT) for loco-regionally advanced nasopharyngeal carcinoma. Methods: Ten previously treated patients with loco-regionally advanced nasopharyngeal carcinoma were replanned with RapidArc and dIMRT, respectively. The prescription dose was GTV 70 Gy/33 f and PTV 60 Gy/33 f. All plans met the requirement: 95% of PTV was covered by 60 Gy. Dose-volume histogram data, isodose distribution, monitor units, and treatment time were compared. Results: Dose distribution has no significant difference between the two techniques. RapidArc reduced the dose of the brainstem, mandible, and other normal tissues compared with dIMRT. Mean monitor units were 589.5 and 1381.0 for RapidArc and dIMRT (reduced by 57% relatively). Mean treatment time was 2.33 min and 7.82 min for RapidArc and dIMRT (reduced by 70% relatively). Conclusions: Compared with dIMRT, RapidArc achieves equal target coverage and OAR sparing while using fewer monitor units and less time during radiotherapy for patient with loco-regionally advanced nasopharyngeal carcinoma. (authors)

  8. SU-E-J-125: A Novel IMRT Planning Technique to Spare Sacral Bone Marrow in Pelvic Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, S; Bhatia, S; Sun, W; Menda, Y; Ponto, L; Gross, B; Buatti, J [University Of Iowa, Iowa City, IA (United States)

    2015-06-15

    Purpose: Develop an IMRT planning technique that can preferentially spare sacral bone marrow for pelvic cancer patients. Methods: Six pelvic cancer patients (two each with anal, cervical, and rectal cancer) were enrolled in an IRB approved protocol to obtain FLT PET images at simulation, during, and post chemoradiation therapy. Initially, conventional IMRT plans were created to maintain target coverage and reduce dose to OARs such as bladder, bowel, rectum, and femoral heads. Simulation FLT PET images were used to create IMRT plans to spare bone marrow identified as regions with SUV of 2 or greater (IMRT-BMS) within the pelvic bones from top of L3 to 5mm below the greater trochanter without compromising PTV coverage or OAR sparing when compared to the initial IMRT plan. IMRT-BMS plans used 8–10 beam angles that surrounded the subject. These plans were used for treatment. Retrospectively, the same simulation FLT PET images were used to create IMRT plans that spared bone marrow located in the sacral pelvic bone region (IMRT-FAN) also without compromising PTV coverage or OAR sparing. IMRT-FAN plans used 16 beam angles every 12° anteriorly from 90° – 270°. Optimization objectives for the sacral bone marrow avoidance region were weighted to reduce ≥V10. Results: IMRT-FAN reduced dose to the sacral bone marrow for all six subjects. The average V5, V10, V20, and V30 differences from the IMRT-BMS plan were −2.2 ± 1.7%, −11.4 ± 3.6%, −17.6 ± 5.1%, and −19.1 ± 8.1% respectively. Average PTV coverage change was 0.5% ± 0.8% from the conventional IMRT plan. Conclusion: An IMRT planning technique that uses beams from the anterior and lateral directions reduced the volume of sacral bone marrow that receives ≤10Gy while maintaining PTV coverage and OAR sparing. Additionally, the volume of sacral bone marrow that received 20 or 30 Gy was also reduced.

  9. Effect of beamlet step-size on IMRT plan quality

    International Nuclear Information System (INIS)

    Zhang Guowei; Jiang Ziping; Shepard, David; Earl, Matt; Yu, Cedric

    2005-01-01

    We have studied the degree to which beamlet step-size impacts the quality of intensity modulated radiation therapy (IMRT) treatment plans. Treatment planning for IMRT begins with the application of a grid that divides each beam's-eye-view of the target into a number of smaller beamlets (pencil beams) of radiation. The total dose is computed as a weighted sum of the dose delivered by the individual beamlets. The width of each beamlet is set to match the width of the corresponding leaf of the multileaf collimator (MLC). The length of each beamlet (beamlet step-size) is parallel to the direction of leaf travel. The beamlet step-size represents the minimum stepping distance of the leaves of the MLC and is typically predetermined by the treatment planning system. This selection imposes an artificial constraint because the leaves of the MLC and the jaws can both move continuously. Removing the constraint can potentially improve the IMRT plan quality. In this study, the optimized results were achieved using an aperture-based inverse planning technique called direct aperture optimization (DAO). We have tested the relationship between pencil beam step-size and plan quality using the American College of Radiology's IMRT test case. For this case, a series of IMRT treatment plans were produced using beamlet step-sizes of 1, 2, 5, and 10 mm. Continuous improvements were seen with each reduction in beamlet step size. The maximum dose to the planning target volume (PTV) was reduced from 134.7% to 121.5% and the mean dose to the organ at risk (OAR) was reduced from 38.5% to 28.2% as the beamlet step-size was reduced from 10 to 1 mm. The smaller pencil beam sizes also led to steeper dose gradients at the junction between the target and the critical structure with gradients of 6.0, 7.6, 8.7, and 9.1 dose%/mm achieved for beamlet step sizes of 10, 5, 2, and 1 mm, respectively

  10. Reducing dose calculation time for accurate iterative IMRT planning

    International Nuclear Information System (INIS)

    Siebers, Jeffrey V.; Lauterbach, Marc; Tong, Shidong; Wu Qiuwen; Mohan, Radhe

    2002-01-01

    A time-consuming component of IMRT optimization is the dose computation required in each iteration for the evaluation of the objective function. Accurate superposition/convolution (SC) and Monte Carlo (MC) dose calculations are currently considered too time-consuming for iterative IMRT dose calculation. Thus, fast, but less accurate algorithms such as pencil beam (PB) algorithms are typically used in most current IMRT systems. This paper describes two hybrid methods that utilize the speed of fast PB algorithms yet achieve the accuracy of optimizing based upon SC algorithms via the application of dose correction matrices. In one method, the ratio method, an infrequently computed voxel-by-voxel dose ratio matrix (R=D SC /D PB ) is applied for each beam to the dose distributions calculated with the PB method during the optimization. That is, D PB xR is used for the dose calculation during the optimization. The optimization proceeds until both the IMRT beam intensities and the dose correction ratio matrix converge. In the second method, the correction method, a periodically computed voxel-by-voxel correction matrix for each beam, defined to be the difference between the SC and PB dose computations, is used to correct PB dose distributions. To validate the methods, IMRT treatment plans developed with the hybrid methods are compared with those obtained when the SC algorithm is used for all optimization iterations and with those obtained when PB-based optimization is followed by SC-based optimization. In the 12 patient cases studied, no clinically significant differences exist in the final treatment plans developed with each of the dose computation methodologies. However, the number of time-consuming SC iterations is reduced from 6-32 for pure SC optimization to four or less for the ratio matrix method and five or less for the correction method. Because the PB algorithm is faster at computing dose, this reduces the inverse planning optimization time for our implementation

  11. Irradiation of head-and-neck tumors with intensity modulated radiotherapy (IMRT). Comparison between two IMRT techniques with 3D conformal irradiation

    International Nuclear Information System (INIS)

    Heeger, Jonas

    2013-01-01

    For 12 patients with inoperable head-neck carcinoma that were treated with 3D conformal irradiation techniques additional irradiation plans using IMRT were developed. It was shown that the IMRT techniques are superior to the 3D conformal technique. The new rapid arc technique is unclear with respect to the critical organs (parotid glands, spinal canal and mandibles) but is significantly advantageous for the other normal tissue with respect to conformity (steeper dose gradients) and thus radiation dose reduction. The resulting lower irradiation time and the reduced radiation exposure being important for the treatment economy and patients' comfort should favor the more planning intensive rapid arc technique.

  12. Radio-chemotherapy in advanced tumors of the oral cavity, oro- and hypopharynx

    International Nuclear Information System (INIS)

    Schmitt, G.; Schnabel, T.

    1992-01-01

    Among combined radio-chemotherapy regimens of advanced head and neck tumors four modalities can be discriminated: 1. Induction chemotherapy, 2. simultaneous radio-chemotherapy, 3. adjuvant chemotherapy, 4. accelerated-hyperfractionated radiotherapy and chemotherapy. The results of the presently available randomized trials are as follows: 1. Induction chemotherapy has no influence on long-term recurrence-free survival. 2. With respect to simultaneous radio-chemotherapy, recurrence-free survival has been unproved with 5-FU and Mitomycin C. 3. There is evidence that adjuvant cis-platin therapy improves recurrence-free survival. 4. No results are available to date using hyperfractionated accelerated radiotherapy regimens in combination with chemotherapy. (orig.) [de

  13. SU-E-T-319: Dosimetric Evaluation of IMRT with Mix-Energy Beam for Deep Seated Targets

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, S; Manigandan, D; Gandhi, A; Sharma, D; Subramani, V; Chander, S; Julkha, P [Fortis Hospital, Mohali, Punjab (India); Rath, G

    2015-06-15

    Purpose: IMRT is preferred in the range of 6–10MV X-rays. Partially adding high energy (>10MV) treatment fields, may provide advantage of both higher and lower energies. To study IMRT dose distribution obtained from treatment plans with single (6MV) and mixed-energy (6MV and 15MV) for deep seated targets (separation more than 30cm). Methods: Five patients of carcinoma of cervix were studied using eclipse planning system. Two different dynamic IMRT plans were generated for Varian CL2300C/D linear accelerator; one is by using 6MV X-ray with seven equally spaced coplanar beams. In second plan, 2 lateral oblique fields (gantry angle 102°, 255°) beam energy was modified to 15MV by keeping all other parameters and dose volume constraints constant. Dose prescription for the planning target volume (PTV) was (5040cGy/28f). For plan comparison, dose volume histogram (DVH) was used and PTV coverage index (CI=Target volume covered by prescription dose/Target volume), heterogeneity index (D5/D95), mean dose to organ at risk (OAR) and normal tissue integral dose (NTID, liter-Gray) was also noted. Total monitor unit (MU) required to deliver a plan was also noted. Results: Mixed-energy plan showed a better conformity and CI values were 0.942±0.032 and 0.960±0.040 for single-energy and mixed-energy plan, respectively. In addition, HI value of mixed energy beam is comparable to that of single energy and the values were within 1.084±0.034 and 1.082±0.032 for single energy and mixed-energy plan, respectively. Variation in mean dose to bladder, rectum and bowel were within 1.05%, 0.87% and 0.90%. NTID was lesser for mixed-energy beam due to use of two high-energy fields. NTID were 1573.40±214.60 and 1510.20±249.80 litre-Gray for single energy and mixed-energy plan. MU needed to deliver a plan was similar in both plans and MUs were 238±45 and 237±47. Conclusion: Partial use of 15MV treatment fields in IMRT plan for deep seated targets showed dosimetric advantage over 6MV

  14. Study on the photoneutrons produced in 15 MV medical linear accelerators : Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Oh Nam [Gangneung Asan Hospital, Gangneung (Korea, Republic of); Yang, Oh Nam; Lim, Cheong Hwan [Hanseo Univ., Seosan (Korea, Republic of)

    2012-12-15

    Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photoneutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photon beams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

  15. Study on the photoneutrons produced in 15 MV medical linear accelerators : Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Yang, Oh Nam; Yang, Oh Nam; Lim, Cheong Hwan

    2012-01-01

    Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photoneutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photon beams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose

  16. Q A IMRT comparison specific patient by means of radiochromic films, radiographic films and ionization chambers arrangement

    International Nuclear Information System (INIS)

    Medina, L.; Venencia, D.; Garrigo, E.

    2014-08-01

    IMRT uses radiation beams of nonuniform intensity. Quality assurance (Q A) specific patient is mandatory in this treatment modality. The purpose of this study is to compare results of patient specific Q A IMRT dose distributions of the total plan and individual fields using different dosimetric systems. We used a photon beam 6 MV generated for linear accelerator PRIMUS, were used planning systems iPLAN and Konrad for IMRT inverse planning with modality Step and Shoot. For plans total dose distributions were measured with radiographic films EDR2 and Radiochromic Film EBT3. For individual fields the dose distributions were measured with radiographic films X-Omat-V, Radiochromic Film EBT3 and PTW 2D-Array. We used a scanner VIDAR Dosimetry Pro Red and software Rit v6.1 for analysis, was used Gamma index [Γ] for comparison of measured and calculated dose recording the number of pixels with Γ> 1. We analyzed 50 plan dose distributions total 50 individual fields. For the total plan the number of pixels with Γ>1 (3%-3m m) was 0.7%±1.2 [0.1%; 2.82%] for EBT3 y 1%±1.8 [0.2%; 3%] for EDR2. For individual fields (5%-3m m) was obtained 0.97%±1,7 [0%, 3%] for X-Omat-V, 0.84%±1.1[0.3%,3.1%] for EBT3 and 2.6%±1.9 [0.01%,6.8%] PTW 2D-Array. All three methods can be used. Radiochromic Films revealed the advantage and disadvantage of the cost. Both systems are slightly better film to PTW 2D-Array. (author)

  17. Preoperative hyperfractionated radiotherapy for locally advanced rectal cancers: a phase I-II trial

    International Nuclear Information System (INIS)

    Allal, Abdelkarim S.; Bieri, Sabine; Bruendler, Marie-Anne; Soravia, Claudio; Gertsch, Philippe; Bernier, Jacques; Morel, Philippe; Roth, Arnaud D.

    2002-01-01

    Purpose: To assess the toxicity, pathologic response rates, type of surgery, and oncologic results in a prospective Phase I-II trial using pure hyperfractionated radiotherapy (RT) preoperatively in locally advanced rectal cancer. Methods and Materials: Between September 1997 and April 2000, 50 patients with T3-T4 or N1 rectal cancers were treated preoperatively with 50 Gy (45 Gy to the pelvis and a 5-Gy tumor boost) in 40 fractions of 1.25 Gy during 4 weeks. The pretreatment tumor stage as determined by CT and endorectal ultrasonography (80% of patients) included 1 Stage T2 (2%), 45 T3 (90%), and 4 T4 (8%). Nodal involvement (N1) was documented in 26 patients (52%). Surgery was performed at a median interval of 45 days (range 26-114 days) after RT completion. Seventeen patients who presented with pT4 or pN1 and/or pM1 received 5-fluorouracil-based chemotherapy postoperatively. Results: All patients completed the RT schedule as planned. Severe acute toxicities included two Grade 3 skin reactions (4%) that did not require a break. The other acute toxicities were Grade 2 or less (skin, diarrhea, urinary, rectal tenesmus, and fatigue). A complete pathologic response was observed in 7 patients (14%), and microscopic residual cancer was found in 10 (20%). Of the 20 patients presenting with tumor located ≤6 cm from the anal verge, sphincter-saving surgery was performed in 14 (70%). At 3 years, the actuarial locoregional control rate was 90.5%, and the disease-free survival rate was 74.6%. At a median follow-up of 32 months, 4 patients (8%) presented with severe late complications (Grade 3-4) that might have been RT related (one rectovaginal fistula, two chronic perineal fistulas, and one bilateral ureteral stenosis). Conclusion: In locally advanced rectal cancer, preoperative hyperfractionated RT to a total dose of 50 Gy is feasible, with acceptable acute and late toxicity and an objective downstaging effect. In view of these results, this schedule might be used as a

  18. Fast IMRT with narrow high energy scanned photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Andreassen, Bjoern; Straaring t, Sara Janek; Holmberg, Rickard; Naefstadius, Peder; Brahme, Anders [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm (Sweden); Department of Hospital Physics, Karolinska University Hospital, SE-171 76 Stockholm (Sweden); Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm, Sweden and Department of Hospital Physics, Karolinska University Hospital, SE-171 76 Stockholm (Sweden)

    2011-08-15

    Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity

  19. Dosimetric Analysis of Unflattened (FFFB) and Flattened (FB) Photon Beam Energy for Gastric Cancers Using IMRT and VMAT-a Comparative Study.

    Science.gov (United States)

    Bhushan, Manindra; Yadav, Girigesh; Tripathi, Deepak; Kumar, Lalit; Kishore, Vimal; Dewan, Abhinav; Kumar, Gourav; Wahi, Inderjit Kaur; Gairola, Munish

    2018-03-08

    To evaluate the feasibility of flattening filter free beam (FFFB) for the treatment of gastric tumors and to review their benefits over 6MV flatten beam (6MV_FFB). Fifteen patients with histologically proven gastric carcinoma were selected. CT scans with slice thickness of 0.3 cm were acquired and planning target volume (PTV) and organ at risk (OAR) were delineated. Plans were made retrospectively for each patient for the prescription dose of 45 Gy/25 fractions to the PTV. Four isocentric plans were compared in the present study on Varian TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, CA, USA). PTV D98% was 44.41 ± 0.12, 44.38 ± 0.13, 44.59 ± 0.14, and 44.49 ± 0.19 Gy for IMRT 6MV_FFB, IMRT 6MV_FFFB, VMAT 6MV_FFB, and VMAT 6MV_FFFB respectively. 6MV_FFFB beam minimizes the mean heart dose D mean (P = 0.001). VMAT dominates over IMRT when it came to kidney doses V 12Gy (P = 0.02), V 23Gy (P = 0.015), V 28Gy (P = 0.011), and D max (P < 0.01). VMAT has significantly reduced the doses to kidneys. It was analyzed that 6MV_FFFB significantly reduces the dose to normal tissues (P = 0.006 and P = 0.018). VMAT significantly reduces the TMU, which is required to deliver the similar dose by IMRT (P < 0.01). Unflattened beam spares the organs at risk significantly to avoid the chances of secondary malignancies and reduces the intra-fraction motion during treatment due to provision of higher dose rate. Hence, we conclude that 6MV unflattened beam can be used to treat gastric carcinoma.

  20. Parotid gland sparing IMRT for head and neck cancer improves xerostomia related quality of life

    Science.gov (United States)

    van Rij, CM; Oughlane-Heemsbergen, WD; Ackerstaff, AH; Lamers, EA; Balm, AJM; Rasch, CRN

    2008-01-01

    Background and purpose To assess the impact of intensity modulated radiotherapy (IMRT) versus conventional radiation on late xerostomia and Quality of Life aspects in head and neck cancer patients. Patients and nethods Questionnaires on xerostomia in rest and during meals were sent to all patients treated between January 1999 and December 2003 with a T1-4, N0-2 M0 head and neck cancer, with parotid gland sparing IMRT or conventional bilateral neck irradiation to a dose of at least 60 Gy, who were progression free and had no disseminated disease (n = 192). Overall response was 85% (n = 163); 97% in the IMRT group (n = 75) and 77% in the control group (n = 88) the median follow-up was 2.6 years. The prevalence of complaints was compared between the two groups, correcting for all relevant factors at multivariate ordinal regression analysis. Results Patients treated with IMRT reported significantly less difficulty transporting and swallowing their food and needed less water for a dry mouth during day, night and meals. They also experienced fewer problems with speech and eating in public. Laryngeal cancer patients in general had fewer complaints than oropharynx cancer patients but both groups benefited from IMRT. Within the IMRT group the xerostomia scores were better for those patients with a mean parotid dose to the "spared" parotid below 26 Gy. Conclusion Parotid gland sparing IMRT for head and neck cancer patients improves xerostomia related quality of life compared to conventional radiation both in rest and during meals. Laryngeal cancer patients had fewer complaints but benefited equally compared to oropharyngeal cancer patients from IMRT. PMID:19068126

  1. Parotid gland sparing IMRT for head and neck cancer improves xerostomia related quality of life

    Directory of Open Access Journals (Sweden)

    Balm AJM

    2008-12-01

    Full Text Available Abstract Background and purpose To assess the impact of intensity modulated radiotherapy (IMRT versus conventional radiation on late xerostomia and Quality of Life aspects in head and neck cancer patients. Patients and nethods Questionnaires on xerostomia in rest and during meals were sent to all patients treated between January 1999 and December 2003 with a T1-4, N0-2 M0 head and neck cancer, with parotid gland sparing IMRT or conventional bilateral neck irradiation to a dose of at least 60 Gy, who were progression free and had no disseminated disease (n = 192. Overall response was 85% (n = 163; 97% in the IMRT group (n = 75 and 77% in the control group (n = 88 the median follow-up was 2.6 years. The prevalence of complaints was compared between the two groups, correcting for all relevant factors at multivariate ordinal regression analysis. Results Patients treated with IMRT reported significantly less difficulty transporting and swallowing their food and needed less water for a dry mouth during day, night and meals. They also experienced fewer problems with speech and eating in public. Laryngeal cancer patients in general had fewer complaints than oropharynx cancer patients but both groups benefited from IMRT. Within the IMRT group the xerostomia scores were better for those patients with a mean parotid dose to the "spared" parotid below 26 Gy. Conclusion Parotid gland sparing IMRT for head and neck cancer patients improves xerostomia related quality of life compared to conventional radiation both in rest and during meals. Laryngeal cancer patients had fewer complaints but benefited equally compared to oropharyngeal cancer patients from IMRT.

  2. SIFT: A method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device

    International Nuclear Information System (INIS)

    Vieira, Sandra C.; Dirkx, Maarten L.P.; Heijmen, Ben J.M.; Boer, Hans C.J. de

    2004-01-01

    Purpose: Radiotherapy patients are increasingly treated with intensity-modulated radiotherapy (IMRT) and high tumor doses. As part of our quality control program to ensure accurate dose delivery, a new method was investigated that enables the verification of the IMRT fluence delivered during patient treatment using an electronic portal imaging device (EPID), irrespective of changes in patient geometry. Methods and materials: Each IMRT treatment field is split into a static field and a modulated field, which are delivered in sequence. Images are acquired for both fields using an EPID. The portal dose image obtained for the static field is used to determine changes in patient geometry between the planning CT scan and the time of treatment delivery. With knowledge of these changes, the delivered IMRT fluence can be verified using the portal dose image of the modulated field. This method, called split IMRT field technique (SIFT), was validated first for several phantom geometries, followed by clinical implementation for a number of patients treated with IMRT. Results: The split IMRT field technique allows for an accurate verification of the delivered IMRT fluence (generally within 1% [standard deviation]), even if large interfraction changes in patient geometry occur. For interfraction radiological path length changes of 10 cm, deliberately introduced errors in the delivered fluence could still be detected to within 1% accuracy. Application of SIFT requires only a minor increase in treatment time relative to the standard IMRT delivery. Conclusions: A new technique to verify the delivered IMRT fluence from EPID images, which is independent of changes in the patient geometry, has been developed. SIFT has been clinically implemented for daily verification of IMRT treatment delivery

  3. Monte Carlo simulations to replace film dosimetry in IMRT verification

    International Nuclear Information System (INIS)

    Goetzfried, Thomas; Trautwein, Marius; Koelbi, Oliver; Bogner, Ludwig; Rickhey, Mark

    2011-01-01

    Patient-specific verification of intensity-modulated radiation therapy (IMRT) plans can be done by dosimetric measurements or by independent dose or monitor unit calculations. The aim of this study was the clinical evaluation of IMRT verification based on a fast Monte Carlo (MC) program with regard to possible benefits compared to commonly used film dosimetry. 25 head-and-neck IMRT plans were recalculated by a pencil beam based treatment planning system (TPS) using an appropriate quality assurance (QA) phantom. All plans were verified both by film and diode dosimetry and compared to MC simulations. The irradiated films, the results of diode measurements and the computed dose distributions were evaluated, and the data were compared on the basis of gamma maps and dose-difference histograms. Average deviations in the high-dose region between diode measurements and point dose calculations performed with the TPS and MC program were 0.7 ± 2.7% and 1.2 ± 3.1%, respectively. For film measurements, the mean gamma values with 3% dose difference and 3 mm distance-to-agreement were 0.74 ± 0.28 (TPS as reference) with dose deviations up to 10%. Corresponding values were significantly reduced to 0.34 ± 0.09 for MC dose calculation. The total time needed for both verification procedures is comparable, however, by far less labor intensive in the case of MC simulations. The presented study showed that independent dose calculation verification of IMRT plans with a fast MC program has the potential to eclipse film dosimetry more and more in the near future. Thus, the linac-specific QA part will necessarily become more important. In combination with MC simulations and due to the simple set-up, point-dose measurements for dosimetric plausibility checks are recommended at least in the IMRT introduction phase. (orig.)

  4. After low and high dose-rate interstitial brachytherapy followed by IMRT radiotherapy for intermediate and high risk prostate cancer

    International Nuclear Information System (INIS)

    Nakamura, Satoshi; Murakami, Naoya; Inaba, Koji; Wakita, Akihisa; Kobayashi, Kazuma; Takahashi, Kana; Okamoto, Hiroyuki; Umezawa, Rei; Morota, Madoka; Sumi, Minako; Igaki, Hiroshi; Ito, Yoshinori; Itami, Jun

    2016-01-01

    The study aimed to compare urinary symptoms in patients with clinically localized prostate cancer after a combination of either low-dose-rate or high-dose-rate interstitial brachytherapy along with intensity-modulated radiation therapy (LDR-ISBT + IMRT or HDR-ISBT + IMRT). From June 2009 to April 2014, 16 and 22 patients were treated with LDR-ISBT + IMRT and HDR-ISBT + IMRT, respectively. No patient from these groups was excluded from this study. The prescribed dose of LDR-ISBT, HDR-ISBT, and IMRT was 115 Gy, 20 Gy in 2 fractions, and 46 Gy in 23 fractions, respectively. Obstructive and irritative urinary symptoms were assessed by the International Prostate Symptom Score (IPSS) examined before and after treatments. After ISBT, IPSS was evaluated in the 1st and 4th weeks, then every 2–3 months for the 1st year, and every 6 months thereafter. The median follow-up of the patients treated with LDR-ISBT + IMRT and HDR-ISBT + IMRT was 1070.5 days and 1048.5 days, respectively (p = 0.321). The IPSS-increment in the LDR-ISBT + IMRT group was greater than that in the HDR-ISBT + IMRT between 91 and 180 days after ISBT (p = 0.015). In the LDR-ISBT + IMRT group, the IPSS took longer time to return to the initial level than in the HDR-ISBT + IMRT group (in LDR-ISBT + IMRT group, the recovery time was 90 days later). The dose to urethra showed a statistically significant association with the IPSS-increment in the irritative urinary symptoms (p = 0.011). Clinical outcomes were comparable between both the groups. Both therapeutic modalities are safe and well suited for patients with clinically localized prostate cancer; however, it took patients longer to recover from LDR-ISBT + IMRT than from HDR-ISBT + IMRT. It is possible that fast dose delivery induced early symptoms and early recovery, while gradual dose delivery induced late symptoms and late recovery. Urethral dose reductions were associated with small increments in IPSS

  5. Local control and intermediate-term cosmetic outcome following IMRT for nasal tumors. An update

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Yuki [University Hospital Zurich, Department of Radiation Oncology, Head Neck Cancer Center, Zurich (Switzerland); Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama (Japan); Janssen, Stefan [University Hospital Zurich, Department of Radiation Oncology, Head Neck Cancer Center, Zurich (Switzerland); Glanzmann, Christoph; Studer, Gabriela [University Hospital Zurich, Department of Radiation Oncology, Head Neck Cancer Center, Zurich (Switzerland); Cantonal Hospital Lucerne, Institute for Radiation Oncology, Lucerne (Switzerland); Holzmann, David [University Hospital Zurich, Department of Otorhinolaryngology, Head and Neck Surgery, Head Neck Cancer Center, Zurich (Switzerland)

    2017-04-15

    This study aims to evaluate local control and intermediate-term cosmetic outcome in patients with cancer of the nose treated with intensity-modulated radiotherapy (IMRT). From June 2008 to September 2015, 36 consecutive patients presenting with nasal cavity, ala of the nose, or nasal vestibule tumors were treated at the Department of Radiation Oncology, University Hospital Zurich either postoperatively (n = 14; 3/14 with nasal ablation) or with definitive IMRT (n = 22). Of these 36 patients, 8 presented with recurrent disease after surgery only and 1/36 with N1 disease. Concurrent systemic therapy was administered in 18/36 patients (50%). Nasal follow-up (FU) imaging documentation of 13 patients with preserved organ and >6 months FU offers a pre/post IMRT FU comparison. In addition, these patients' subjective evaluation of cosmesis was assessed. Mean/median FU was 41/33 months (range 5-92 months). Salvage ablation with curative intent was undergone by 3 patients with local relapse after definitive (n = 2) and postoperative (n = 1) IMRT. The 3-year local control, ultimate local control, and overall survival rates were 90, 97, and 90 %, respectively. Subjective and objective cosmetic outcome after IMRT is very satisfying so far. IMRT for nasal tumors was found to be effective and well tolerated. Intermediate-term cosmetic results are good. Radical surgical procedures may be saved for curative salvage treatment. (orig.) [German] Evaluation der Lokalkontrolle und des mittelfristigen kosmetischen Resultats nach intensitaetsmodulierter Radiotherapie (IMRT) von Patienten mit Nasentumoren. Von Juni 2008 bis September 2015 wurden an der Klinik fuer RadioOnkologie am UniversitaetsSpital Zuerich 36 konsekutive Patienten mit Tumoren der Nasenhoehle, der Nasenfluegel oder des Vestibulum nasi postoperativ (n = 14; 3/14 nach Nasenablation) oder definitiv IMRT-bestrahlt (n = 22). Von diesen 36 Patienten zeigten 8 ein Lokalrezidiv nach alleiniger vorangegangener Chirurgie und

  6. Dosimetric comparison of treatment techniques IMRT and VMAT for breast cancer; Comparacion dosimetrica de las tecnicas de tratamiento IMRT y VMAT para cancer en mama

    Energy Technology Data Exchange (ETDEWEB)

    Urbina, G. L. [Universidad Nacional de Ingenieria, Maestria en Fisica Medica, Av. Tupac Amaru s/n, Rimac, Lima 25 (Peru); Garcia, B. G., E-mail: gerlup@hotmail.com [Red AUNA, Clinica Delgado, Av. Angamos Cdra. 4 esquina Gral. Borgono, Miraflores, Lima (Peru)

    2015-10-15

    In this study the dosimetric distribution was compared in the different treatment techniques such as Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) in female patients with breast cancer with stage II-B and III-A, 6 cases (both calculated on VMAT and IMRT) were studied, comparison parameter that are taken into account are: compliance rate, homogeneity index, monitor units, volume dose 50 Gy (D-50%) and 5 Gy (D-5%) volume dose. Comparisons are made in primary tumor volume to optimize treatment in patients with breast cancer, with IMRT using Step, Shoot and VMAT Monte Carlo algorithm, in addition to the organs at risk; the concern to make this work is due to technological advances in radiotherapy and the application of new treatment techniques, that increase the accuracy allowing treatment dose climbing delivering a higher dose to the patient. (Author)

  7. Simulation of respiratory motion during IMRT dose delivery

    International Nuclear Information System (INIS)

    Mohn, Silje; Wasboe, Ellen

    2011-01-01

    Background. When intensity modulated radiation therapy (IMRT) is realised with dynamic multi-leaf collimators (MLC) and given under respiratory motion, dosimetric errors may occur. These errors are a consequence of the dose blurring and the interplay between the organ motion and the leaf motion. In the present study, a model for evaluating these dosimetric effects for patient-specific cases has been developed and tested. Material and methods. In the purpose written software, three dimensional (3D) dose distributions can be calculated both with and without a generated breathing cycle. To validate the presented model and illustrate its application, periodic breathing cycles were generated, where the starting phase was set randomly for each field during the calculations. Respiration in the anterior-posterior (AP), superior-inferior (SI) and left-right (LR) direction was tested and verified. To illustrate the application of the presented model, two 5-fields IMRT plans with different complexity were calculated with a 2 cm peak-to-peak motion in the AP direction for one fraction and for 25 fractions. Results. The results showed that the calculation method is of good accuracy, in particular for IMRT plans consisting of several fields, where 97% of the pixels within the body fulfilled a tolerance set to 4% dose difference and 4 mm distance to agreement (DTA). For the two IMRT plans with different complexity, pronounced respiratory induced dose errors, which increased with increasing complexity, were found for both one fraction and 25 fractions, but due to the random stating phase the interplay effect was considerably reduced for the plans consisting of 25 fractions. This illustrates how the dosimetric effects will vary depending on the dose plan and on the number of fractions investigated. Conclusion. For patient specific cases, the model can with good accuracy calculate 3D dose distributions both with and without respiratory motion, and evaluate the dosimetric effects

  8. A comparison of HDR brachytherapy and IMRT techniques for dose escalation in prostate cancer: A radiobiological modeling study

    Energy Technology Data Exchange (ETDEWEB)

    Fatyga, M.; Williamson, J. F.; Dogan, N.; Todor, D.; Siebers, J. V.; George, R.; Barani, I.; Hagan, M. [Department of Radiation Oncology, Virginia Commonwealth University Medical Center, 401 College Street, Richmond, Virginia 23298 (United States)

    2009-09-15

    A course of one to three large fractions of high dose rate (HDR) interstitial brachytherapy is an attractive alternative to intensity modulated radiation therapy (IMRT) for delivering boost doses to the prostate in combination with additional external beam irradiation for intermediate risk disease. The purpose of this work is to quantitatively compare single-fraction HDR boosts to biologically equivalent fractionated IMRT boosts, assuming idealized image guided delivery (igIMRT) and conventional delivery (cIMRT). For nine prostate patients, both seven-field IMRT and HDR boosts were planned. The linear-quadratic model was used to compute biologically equivalent dose prescriptions. The cIMRT plan was evaluated as a static plan and with simulated random and setup errors. The authors conclude that HDR delivery produces a therapeutic ratio which is significantly better than the conventional IMRT and comparable to or better than the igIMRT delivery. For the HDR, the rectal gBEUD analysis is strongly influenced by high dose DVH tails. A saturation BED, beyond which no further injury can occur, must be assumed. Modeling of organ motion uncertainties yields mean outcomes similar to static plan outcomes.

  9. DARS: a phase III randomised multicentre study of dysphagia- optimised intensity- modulated radiotherapy (Do-IMRT) versus standard intensity- modulated radiotherapy (S-IMRT) in head and neck cancer

    International Nuclear Information System (INIS)

    Petkar, Imran; Rooney, Keith; Roe, Justin W. G.; Patterson, Joanne M.; Bernstein, David; Tyler, Justine M.; Emson, Marie A.; Morden, James P.; Mertens, Kathrin; Miles, Elizabeth; Beasley, Matthew; Roques, Tom; Bhide, Shreerang A.; Newbold, Kate L.; Harrington, Kevin J.; Hall, Emma; Nutting, Christopher M.

    2016-01-01

    Persistent dysphagia following primary chemoradiation (CRT) for head and neck cancers can have a devastating impact on patients’ quality of life. Single arm studies have shown that the dosimetric sparing of critical swallowing structures such as the pharyngeal constrictor muscle and supraglottic larynx can translate to better functional outcomes. However, there are no current randomised studies to confirm the benefits of such swallow sparing strategies. The aim of Dysphagia/Aspiration at risk structures (DARS) trial is to determine whether reducing the dose to the pharyngeal constrictors with dysphagia-optimised intensity- modulated radiotherapy (Do-IMRT) will lead to an improvement in long- term swallowing function without having any detrimental impact on disease-specific survival outcomes. The DARS trial (CRUK/14/014) is a phase III multicentre randomised controlled trial (RCT) for patients undergoing primary (chemo) radiotherapy for T1-4, N0-3, M0 pharyngeal cancers. Patients will be randomised (1:1 ratio) to either standard IMRT (S-IMRT) or Do-IMRT. Radiotherapy doses will be the same in both groups; however in patients allocated to Do-IMRT, irradiation of the pharyngeal musculature will be reduced by delivering IMRT identifying the pharyngeal muscles as organs at risk. The primary endpoint of the trial is the difference in the mean MD Anderson Dysphagia Inventory (MDADI) composite score, a patient-reported outcome, measured at 12 months post radiotherapy. Secondary endpoints include prospective and longitudinal evaluation of swallow outcomes incorporating a range of subjective and objective assessments, quality of life measures, loco-regional control and overall survival. Patients and speech and language therapists (SLTs) will both be blinded to treatment allocation arm to minimise outcome-reporting bias. DARS is the first RCT investigating the effect of swallow sparing strategies on improving long-term swallowing outcomes in pharyngeal cancers. An integral

  10. Dose distribution of IMRT and 3D-CRT on treating central non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Zhu Xiaoyang; Yu Guangwei

    2010-01-01

    3D-CRT and IMRT were used in the radiation therapy of Central Non-small-cell lung cancer (NSCLC), and the dose difference of the methods was estimated. Thirty-two patients suffering with II class NSCLC were selected. Based on CT images, each patient was given 1 3D-CRT (3 dimensional conformal radiotherapy) and 2 IMRT(intensity modulated radiation therapy) treatment plans (5 fields and 7 fields), respectively, and the dose distribution was evaluated too. The results showed that PTVD mean and the PTV max , PTVD max (%) and CI of IMRT were both higher than those of 3D-CRT, but the uniformity was not as good as 3D-CRT. All indexes of lung and spinal cord treated with IMRT were lower than that treated with 3D-CRT. Moreover, there was no significance of the difference between 5 fields and 7 fields. In a conclusion, IMRT could not only decrease the target dose of NSCLC, but it can protect normal tissue from radiation damage effectively. And when IMRT was used, 5 fields might be enough. (authors)

  11. A potential to reduce pulmonary toxicity: The use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Christian, Judith A.; Partridge, Mike; Niotsikou, Elena; Cook, Gary; Parker, Michelle; Bedford, James L.; Brada, Michael

    2007-01-01

    Background and purpose: The study aimed to examine specific avoidance of functional lung (FL) defined by a single photon emission computerized tomography (SPECT) lung perfusion scan, using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3-DCRT) in patients with non-small cell lung cancer (NSCLC). Materials and methods: Patients with NSCLC underwent planning computerized tomography (CT) and lung perfusion SPECT scan in the treatment position using fiducial markers to allow co-registration in the treatment planning system. Radiotherapy (RT) volumes were delineated on the CT scan. FL was defined using co-registered SPECT images. Two inverse coplanar RT plans were generated for each patient: 4-field 3-DCRT and 5-field step-and-shoot IMRT. 3-DCRT plans were created using automated AutoPlan optimisation software, and IMRT plans were generated employing Pinnacle 3 treatment planning system (Philips Radiation Oncology Systems). All plans were prescribed to 64 Gy in 32 fractions using data for the 6 MV beam from an Elekta linear accelerator. The objectives for both plans were to minimize the volume of FL irradiated to 20 Gy (fV 20 ) and dose variation within the planning target volume (PTV). A spinal cord dose was constrained to 46 Gy. Volume of PTV receiving 90% of the prescribed dose (PTV 90 ), fV 20 , and functional mean lung dose (fMLD) were recorded. The PTV 90 /fV 20 ratio was used to account for variations in both measures, where a higher value represented a better plan. Results: Thirty-four RT plans of 17 patients with stage I-IIIB NSCLC suitable for radical RT were analysed. In 6 patients with stage I-II disease there was no improvement in PTV 90 , fV 20 , PTV/fV 20 ratio and fMLD using IMRT compared to 3-DCRT. In 11 patients with stage IIIA-B disease, the PTV was equally well covered with IMRT and 3-DCRT plans, with IMRT producing better PTV 90 /fV 20 ratio (mean ratio - 7.2 vs. 5.3, respectively, p = 0.001) and reduced f

  12. Pre-segmented 2-Step IMRT with subsequent direct machine parameter optimisation – a planning study

    International Nuclear Information System (INIS)

    Bratengeier, Klaus; Meyer, Jürgen; Flentje, Michael

    2008-01-01

    Modern intensity modulated radiotherapy (IMRT) mostly uses iterative optimisation methods. The integration of machine parameters into the optimisation process of step and shoot leaf positions has been shown to be successful. For IMRT segmentation algorithms based on the analysis of the geometrical structure of the planning target volumes (PTV) and the organs at risk (OAR), the potential of such procedures has not yet been fully explored. In this work, 2-Step IMRT was combined with subsequent direct machine parameter optimisation (DMPO-Raysearch Laboratories, Sweden) to investigate this potential. In a planning study DMPO on a commercial planning system was compared with manual primary 2-Step IMRT segment generation followed by DMPO optimisation. 15 clinical cases and the ESTRO Quasimodo phantom were employed. Both the same number of optimisation steps and the same set of objective values were used. The plans were compared with a clinical DMPO reference plan and a traditional IMRT plan based on fluence optimisation and consequent segmentation. The composite objective value (the weighted sum of quadratic deviations of the objective values and the related points in the dose volume histogram) was used as a measure for the plan quality. Additionally, a more extended set of parameters was used for the breast cases to compare the plans. The plans with segments pre-defined with 2-Step IMRT were slightly superior to DMPO alone in the majority of cases. The composite objective value tended to be even lower for a smaller number of segments. The total number of monitor units was slightly higher than for the DMPO-plans. Traditional IMRT fluence optimisation with subsequent segmentation could not compete. 2-Step IMRT segmentation is suitable as starting point for further DMPO optimisation and, in general, results in less complex plans which are equal or superior to plans generated by DMPO alone

  13. Kidney-Sparing Methods for Extended-Field Intensity-Modulated Radiotherapy (EF-IMRT) in Cervical Carcinoma Treatment.

    Science.gov (United States)

    Kunogi, Hiroaki; Yamaguchi, Nanae; Terao, Yasuhisa; Sasai, Keisuke

    2016-01-01

    Coplanar extended-field intensity-modulated radiation therapy (EF-IMRT) targeting the whole-pelvic and para-aortic lymph nodes in patients with advanced cervical cancer results in impaired creatinine clearance. An improvement in renal function cannot be expected unless low-dose (approximately 10 Gy) kidney exposure is reduced. The dosimetric method should be considered during EF-IMRT planning to further reduce low-dose exposure to the kidneys. To assess the usefulness of non-coplanar EF-IMRT with kidney-avoiding beams to spare the kidneys during cervical carcinoma treatment in dosimetric analysis between non-coplanar and coplanar EF-IMRT, we compared the doses of the target organ and organs at risk, including the kidney, in 10 consecutive patients. To estimate the influence of EFRT on renal dysfunction, creatinine clearance values after treatment were also examined in 18 consecutive patients. Of these 18 patients, 10 patients who were included in the dosimetric analysis underwent extended field radiation therapy (EFRT) with concurrent chemotherapy, and eight patients underwent whole-pelvis radiation therapy with concurrent chemotherapy to treat cervical carcinoma between April 2012 and March 2015 at our institution. In the dosimetric analysis, non-coplanar EF-IMRT was effective at reducing low-dose (approximately 10 Gy) exposure to the kidneys, thus maintaining target coverage and sparing other organs at risk, such as the small bowel, rectum, and bladder, compared with coplanar EF-IMRT. Renal function in all 10 patients who underwent EFRT, including coplanar EF-IMRT (with kidney irradiation), was low after treatment, and differed significantly from that of the eight patients who underwent WPRT (no kidney irradiation) 6 months after the first day of treatment (P = 0.005). In conclusion, non-coplanar EF-IMRT should be considered in patients with advanced cervical cancer, particularly in patients with a long life expectancy or with pre-existing renal dysfunction.

  14. Analysis of late complications after rapid hyperfractionated radiotherapy in advanced head and neck cancers

    International Nuclear Information System (INIS)

    Nguyen, T.D.; Panis, X.; Froissart, D.; Legros, M.; Coninx, P.; Loirette, M.

    1988-01-01

    Late effects were analyzed in a series of 39 patients with a 2-year minimal follow-up who were treated by rapid hyperfractionated radiotherapy. The total dose was 66-72 Gy delivered in two series of 33-36 Gy separated by a 2-4 week rest interval. The number of daily fractions ranged from 8 to 6 and the interval between each fraction was 2 hr. Late complications consisted of cervical fibrosis, mucosal necrosis, bone necrosis, trismus, and laryngeal edema. Seventy percent of patients experienced late complications, and in 54% of cases, these reactions were considered severe, causing death in 13% of patients. No relationship was found between field sizes, dosimetric data and type and frequency of late effects. It is therefore suggested that the interval between two daily sessions in any multifractionated protocol may be of critical importance

  15. Analysis of results of checks IMRT in almost a thousand patients

    International Nuclear Information System (INIS)

    Richart, J.; Doval, S.; Perez-Calatayud, J.; Depieaggio, M.; Rodriguez, S.; Santos, M.

    2013-01-01

    Since November 2006 IMRT treatments being made in the mode of sliding-window in our Hospital. The major sites of application of this technique are: head and neck, prostate, and gynecological. Specific checks are performed of each plan both yield and analysis ionometric extent in which a dummy was exported IMRT plan. Over one thousand patients, the objective of this work is the presentation and analysis of results. (Author)

  16. Split Course Hyperfractionated Accelerated Radio-Chemotherapy (SCHARC for patients with advanced head and neck cancer: Influence of protocol deviations and hemoglobin on overall survival, a retrospective analysis

    Directory of Open Access Journals (Sweden)

    Sprague Lisa D

    2006-12-01

    Full Text Available Abstract Background The advantage of hyperfractionated accelerated radiation therapy for advanced head and neck cancer has been reported. Furthermore, randomized trials and meta-analyses have confirmed the survival benefit of additional chemotherapy to radiotherapy. We retrospectively analyzed the efficiency and toxicity of the Regensburg standard therapy protocol "SCHARC" and the overall survival of our patients. Methods From 1997 to 2004, 64 patients suffering from advanced head and neck cancer (88 % stage IV, 12 % stage III were assigned to receive the SCHARC protocol. Around half of the patients were diagnosed with oro-hypopharynx carcinoma (52 %, one third with tongue and floor of mouth tumors (29 % and one fifth (19 % suffered from H & N cancer at other sites. The schedule consisted of one therapy block with 30 Gy in 20 fractions over a two week period with concomitant chemotherapy (d 1–5: 20 mg/m2/d DDP + 750–1000 mg/m2/d 5FU (cont. infusion. This therapy block was repeated after a fortnight break up to a cumulative dose of 60 Gy and followed by a boost up to 70 Gy (69–70.5 Gy. All patients assigned to this scheme were included in the survival evaluation. Results Forty patients (63 % received both radiation and chemotherapy according to the protocol. The mean follow up was 2.3 years (829 d and the median follow up was 1.9 years (678 d, respectively. The analysis of survival revealed an estimated 3 year overall survival rate of 57 %. No patient died of complications, 52 patients (80 % had acute grade 2–3 mucositis, and 33 patients (58 % suffered from acute grade 3 skin toxicity. Leucopenia was no major problem (mean nadir 3.4 g/nl, no patient 10.5 g/dl and for patients who completed the protocol. Conclusion The SCHARC protocol was effective in patients diagnosed with advanced head and neck cancer. It led to long-term disease control and survival in about 50 % of the patients with significant but acceptable toxicity. Most patients

  17. Split Course Hyperfractionated Accelerated Radio-Chemotherapy (SCHARC) for patients with advanced head and neck cancer: Influence of protocol deviations and hemoglobin on overall survival, a retrospective analysis

    International Nuclear Information System (INIS)

    Stadler, Peter; Putnik, Kurt; Kreimeyer, Thore; Sprague, Lisa D; Koelbl, Oliver; Schäfer, Christof

    2006-01-01

    The advantage of hyperfractionated accelerated radiation therapy for advanced head and neck cancer has been reported. Furthermore, randomized trials and meta-analyses have confirmed the survival benefit of additional chemotherapy to radiotherapy. We retrospectively analyzed the efficiency and toxicity of the Regensburg standard therapy protocol 'SCHARC' and the overall survival of our patients. From 1997 to 2004, 64 patients suffering from advanced head and neck cancer (88 % stage IV, 12 % stage III) were assigned to receive the SCHARC protocol. Around half of the patients were diagnosed with oro-hypopharynx carcinoma (52 %), one third with tongue and floor of mouth tumors (29 %) and one fifth (19 %) suffered from H & N cancer at other sites. The schedule consisted of one therapy block with 30 Gy in 20 fractions over a two week period with concomitant chemotherapy (d 1–5: 20 mg/m 2 /d DDP + 750–1000 mg/m 2 /d 5FU (cont. infusion). This therapy block was repeated after a fortnight break up to a cumulative dose of 60 Gy and followed by a boost up to 70 Gy (69–70.5 Gy). All patients assigned to this scheme were included in the survival evaluation. Forty patients (63 %) received both radiation and chemotherapy according to the protocol. The mean follow up was 2.3 years (829 d) and the median follow up was 1.9 years (678 d), respectively. The analysis of survival revealed an estimated 3 year overall survival rate of 57 %. No patient died of complications, 52 patients (80 %) had acute grade 2–3 mucositis, and 33 patients (58 %) suffered from acute grade 3 skin toxicity. Leucopenia was no major problem (mean nadir 3.4 g/nl, no patient < 1.0 g/nl) and the mean hemoglobin value decreased from 13.2 to 10.5 g/dl. Univariate analysis of survival showed a better outcome for patients with a hemoglobin nadir >10.5 g/dl and for patients who completed the protocol. The SCHARC protocol was effective in patients diagnosed with advanced head and neck cancer. It led

  18. Split course hyperfractionated accelerated radio-chemotherapy (SCHARC) for patients with advanced head and neck cancer: influence of protocol deviations and hemoglobin on overall survival, a retrospective analysis.

    Science.gov (United States)

    Stadler, Peter; Putnik, Kurt; Kreimeyer, Thore; Sprague, Lisa D; Koelbl, Oliver; Schäfer, Christof

    2006-12-07

    The advantage of hyperfractionated accelerated radiation therapy for advanced head and neck cancer has been reported. Furthermore, randomized trials and meta-analyses have confirmed the survival benefit of additional chemotherapy to radiotherapy. We retrospectively analyzed the efficiency and toxicity of the Regensburg standard therapy protocol "SCHARC" and the overall survival of our patients. From 1997 to 2004, 64 patients suffering from advanced head and neck cancer (88 % stage IV, 12 % stage III) were assigned to receive the SCHARC protocol. Around half of the patients were diagnosed with oro-hypopharynx carcinoma (52 %), one third with tongue and floor of mouth tumors (29 %) and one fifth (19 %) suffered from H & N cancer at other sites. The schedule consisted of one therapy block with 30 Gy in 20 fractions over a two week period with concomitant chemotherapy (d 1-5: 20 mg/m2/d DDP + 750-1000 mg/m2/d 5FU (cont. infusion). This therapy block was repeated after a fortnight break up to a cumulative dose of 60 Gy and followed by a boost up to 70 Gy (69-70.5 Gy). All patients assigned to this scheme were included in the survival evaluation. Forty patients (63 %) received both radiation and chemotherapy according to the protocol. The mean follow up was 2.3 years (829 d) and the median follow up was 1.9 years (678 d), respectively. The analysis of survival revealed an estimated 3 year overall survival rate of 57 %. No patient died of complications, 52 patients (80 %) had acute grade 2-3 mucositis, and 33 patients (58 %) suffered from acute grade 3 skin toxicity. Leucopenia was no major problem (mean nadir 3.4 g/nl, no patient hemoglobin value decreased from 13.2 to 10.5 g/dl. Univariate analysis of survival showed a better outcome for patients with a hemoglobin nadir >10.5 g/dl and for patients who completed the protocol. The SCHARC protocol was effective in patients diagnosed with advanced head and neck cancer. It led to long-term disease control and survival in

  19. A case study of IMRT planning (Plan B) subsequent to a previously treated IMRT plan (Plan A)

    International Nuclear Information System (INIS)

    2Department of Radiation Oncology, Fraser Valley Centre, BC Cancer Agency, Surrey, British Columbia (Canada))" data-affiliation=" (Department of Medical Physics and 2Department of Radiation Oncology, Fraser Valley Centre, BC Cancer Agency, Surrey, British Columbia (Canada))" >Cao, F; 2Department of Radiation Oncology, Fraser Valley Centre, BC Cancer Agency, Surrey, British Columbia (Canada))" data-affiliation=" (Department of Medical Physics and 2Department of Radiation Oncology, Fraser Valley Centre, BC Cancer Agency, Surrey, British Columbia (Canada))" >Leong, C; 2Department of Radiation Oncology, Fraser Valley Centre, BC Cancer Agency, Surrey, British Columbia (Canada))" data-affiliation=" (Department of Medical Physics and 2Department of Radiation Oncology, Fraser Valley Centre, BC Cancer Agency, Surrey, British Columbia (Canada))" >Schroeder, J; 2Department of Radiation Oncology, Fraser Valley Centre, BC Cancer Agency, Surrey, British Columbia (Canada))" data-affiliation=" (Department of Medical Physics and 2Department of Radiation Oncology, Fraser Valley Centre, BC Cancer Agency, Surrey, British Columbia (Canada))" >Lee, B

    2014-01-01

    Background and purpose: Treatment of the contralateral neck after previous ipsilateral intensity modulated radiation therapy (IMRT) for head and neck cancer is a challenging problem. We have developed a technique that limits the cumulative dose to the spinal cord and brainstem while maximizing coverage of a planning target volume (PTV) in the contralateral neck. Our case involves a patient with right tonsil carcinoma who was given ipsilateral IMRT with 70Gy in 35 fractions (Plan A). A left neck recurrence was detected 14 months later. The patient underwent a neck dissection followed by postoperative left neck radiation to a dose of 66 Gy in 33 fractions (Plan B). Materials and Methods: The spinal cord-brainstem margin (SCBM) was defined as the spinal cord and brainstem with a 1.0 cm margin. Plan A was recalculated on the postoperative CT scan but the fluence outside of SCBM was deleted. A further modification of Plan A resulted in a base plan that was summed with Plan B to evaluate the cumulative dose received by the spinal cord and brainstem. Plan B alone was used to evaluate for coverage of the contralateral neck PTV. Results: The maximum cumulative doses to the spinal cord with 0.5cm margin and brainstem with 0.5cm margin were 51.96 Gy and 45.60 Gy respectively. For Plan B, 100% of the prescribed dose covered 95% of PTVb1. Conclusion: The use of a modified ipsilateral IMRT plan as a base plan is an effective way to limit the cumulative dose to the spinal cord and brainstem while enabling coverage of a PTV in the contralateral neck.

  20. Validation of the implementation of IMRT with three dosimetric methods of independent verification; Validacion de la puesta en marcha de la IMRT con tres metodos dosimetricos de verificacion independientes

    Energy Technology Data Exchange (ETDEWEB)

    Tortosa Oliver, R. A.; Chinillach ferrando, N.; Alonso Arrizabalaga, S.; Campayo Esteban, J. M.; Morales Marco, J. C.; Soler Catalan, P.; Andreu Martinez, F. J.

    2013-07-01

    The TG119 is a simple and clear framework to verify the implementation of IMRT technique in a radiotherapy service. Verifications of this document recommended tests conducted with the three dosimetric methods listed above, allow to affirm that our Center is within the margins of tolerance considered suitable in the TG119 for the clinical implementation of IMRT. (Author)

  1. Comparison of dental health of patients with head and neck cancer receiving IMRT vs conventional radiation.

    Science.gov (United States)

    Duarte, Victor M; Liu, Yuan F; Rafizadeh, Sassan; Tajima, Tracey; Nabili, Vishad; Wang, Marilene B

    2014-01-01

    To analyze the dental health of patients with head and neck cancer who received comprehensive dental care after intensity-modulated radiation therapy (IMRT) compared with radiation therapy (RT). Historical cohort study. Veteran Affairs (VA) hospital. In total, 158 patients at a single VA hospital who were treated with RT or IMRT between 2003 and 2011 were identified. A complete dental evaluation was performed prior to radiation treatment, including periodontal probing, tooth profile, cavity check, and mobility. The dental treatment plan was formulated to eliminate current and potential dental disease. The rates of dental extractions, infections, caries, mucositis, xerostomia, and osteoradionecrosis (ORN) were analyzed, and a comparison was made between patients treated with IMRT and those treated with RT. Of the 158 patients, 99 were treated with RT and 59 were treated with IMRT. Compared with those treated with IMRT, significantly more patients treated with RT exhibited xerostomia (46.5% vs 16.9%; P radiation treatment (32.2% vs 11.1%; P = .002; OR, 3.8; 95% CI, 1.65-8.73). Patients who were treated with IMRT had fewer instances of dental disease, more salivary flow, and fewer requisite posttreatment extractions compared with those treated with RT. The number of posttreatment extractions has been reduced with the advent of IMRT and more so with a complete dental evaluation prior to treatment.

  2. TU-C-BRE-01: KEYNOTE PRESENTATION - Emerging Frontiers in IMRT QA

    Energy Technology Data Exchange (ETDEWEB)

    Siebers, J [University of Virginia Health System, Charlottesville, VA (United States)

    2014-06-15

    As IMRT treatment processes advance and mature, so must the quality assurance processes being used to validate their delivery. In some respects, treatment delivery advancements (e.g. VMAT) have out-paced QA advancements. The purpose of this session is to describe new processes that are being implemented to bring IMRT QA up-to-date with the treatment delivery advances. It would explore emerging IMRT QA paradigms, including requirements-based IMRT QA which necessitates definition of delivery errors (e.g. patient dose error, leaf positioning error) and development of processes to ensure reliable error detection. Engineeringbased QA approaches, including use of IMRT treatment delivery process trees, fault tree analysis and failure modes effects analysis would be described. Approaches to detect errors such as (1) during treatment delivery validation using exit fluence detectors (e.g. EPIDs); (2) analysis of treatment delivery via use of machine parameter log files; (3) dose recalculation using (3a) treatment planning system; (3b) record-and-verify; or (3c) entrance and exit fluence measurement parameters would be explained. The relative advantages and disadvantages of each method would be discussed. Schemes for error classification and root cause analysis would be described – steps which are essential for future error prevention. For each QA method, testing procedures and results would be presented indicating the types of errors that can be detected, those that cannot be detected, and the reliability of the error detection method (for example determined via ROC analysis). For speakers, we are seeking to engage non-commercially biased experts. Those listed below are a sub-sample of possible qualified individuals.

  3. TU-C-BRE-01: KEYNOTE PRESENTATION - Emerging Frontiers in IMRT QA

    International Nuclear Information System (INIS)

    Siebers, J

    2014-01-01

    As IMRT treatment processes advance and mature, so must the quality assurance processes being used to validate their delivery. In some respects, treatment delivery advancements (e.g. VMAT) have out-paced QA advancements. The purpose of this session is to describe new processes that are being implemented to bring IMRT QA up-to-date with the treatment delivery advances. It would explore emerging IMRT QA paradigms, including requirements-based IMRT QA which necessitates definition of delivery errors (e.g. patient dose error, leaf positioning error) and development of processes to ensure reliable error detection. Engineeringbased QA approaches, including use of IMRT treatment delivery process trees, fault tree analysis and failure modes effects analysis would be described. Approaches to detect errors such as (1) during treatment delivery validation using exit fluence detectors (e.g. EPIDs); (2) analysis of treatment delivery via use of machine parameter log files; (3) dose recalculation using (3a) treatment planning system; (3b) record-and-verify; or (3c) entrance and exit fluence measurement parameters would be explained. The relative advantages and disadvantages of each method would be discussed. Schemes for error classification and root cause analysis would be described – steps which are essential for future error prevention. For each QA method, testing procedures and results would be presented indicating the types of errors that can be detected, those that cannot be detected, and the reliability of the error detection method (for example determined via ROC analysis). For speakers, we are seeking to engage non-commercially biased experts. Those listed below are a sub-sample of possible qualified individuals

  4. MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

    International Nuclear Information System (INIS)

    Valdes, G; Scheuermann, R; Solberg, T; Chan, M; Deasy, J

    2016-01-01

    Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

  5. MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

    Energy Technology Data Exchange (ETDEWEB)

    Valdes, G; Scheuermann, R; Solberg, T [University of Pennsylvania, Philadelphia, PA (United States); Chan, M; Deasy, J [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

  6. Histopathological changes in the irradiated normal organs of guinea pigs with conventional fractionation and hyperfractionation

    International Nuclear Information System (INIS)

    Inomata, Taisuke; Itoh, Satoshi; Tsuboi, Nobuaki

    1998-01-01

    Guinea pigs were divided into groups according to four irradiation schedules : 2 Gy/3 Gy x 1/day, five fractions/week, total 80 Gy/81 Gy (A/C group) and 1.0 Gy/1.5 Gy x 2/day, ten fractions/week, total 80 Gy/81 Gy (B/D group). The A group and the C group pathologically caused severe damage in the kidney six and three months after irradiation, respectively. In the B group pathological analysis suggested that only slight-to-moderate changes were occurred in the Bowman's capsule. The D group caused slight damage in the kidney six months after irradiation. Hyperfractionation (B/D group) used in this protocol can clearly reduce radiation damage in the kidney of guinea pigs as compared with conventional fractionation (A/C group). (author)

  7. Clinical implementation of dose-volume histogram predictions for organs-at-risk in IMRT planning

    International Nuclear Information System (INIS)

    Moore, K L; Appenzoller, L M; Tan, J; Michalski, J M; Thorstad, W L; Mutic, S

    2014-01-01

    True quality control (QC) of the planning process requires quantitative assessments of treatment plan quality itself, and QC in IMRT has been stymied by intra-patient anatomical variability and inherently complex three-dimensional dose distributions. In this work we describe the development of an automated system to reduce clinical IMRT planning variability and improve plan quality using mathematical models that predict achievable OAR DVHs based on individual patient anatomy. These models rely on the correlation of expected dose to the minimum distance from a voxel to the PTV surface, whereby a three-parameter probability distribution function (PDF) was used to model iso-distance OAR subvolume dose distributions. DVH models were obtained by fitting the evolution of the PDF with distance. Initial validation on clinical cohorts of 40 prostate and 24 head-and-neck plans demonstrated highly accurate model-based predictions for achievable DVHs in rectum, bladder, and parotid glands. By quantifying the integrated difference between candidate DVHs and predicted DVHs, the models correctly identified plans with under-spared OARs, validated by replanning all cases and correlating any realized improvements against the predicted gains. Clinical implementation of these predictive models was demonstrated in the PINNACLE treatment planning system by use of existing margin expansion utilities and the scripting functionality inherent to the system. To maintain independence from specific planning software, a system was developed in MATLAB to directly process DICOM-RT data. Both model training and patient-specific analyses were demonstrated with significant computational accelerations from parallelization.

  8. Final report of a randomized trial on altered-fractionated radiotherapy in nasopharyngeal carcinoma prematurely terminated by significant increase in neurologic complications

    International Nuclear Information System (INIS)

    Teo, Peter Man Lung; Leung, Sing Fai; Chan, Anthony Tak Cheung; Leung, Thomas Wai Tong; Choi, Peter Ho Keung; Kwan, Wing Hong; Lee, Wai Yee; Chau, Ricky Ming Chun; Yu, Peter Kau Wing; Johnson, Philip James

    2000-01-01

    Purpose: The aim of the present study was to compare the survival, local control and complications of conventional/accelerated-hyperfractionated radiotherapy and conventional radiotherapy in nonmetastatic nasopharyngeal carcinoma (NPC). Methods and Materials: From February 1993 to October 1995, 159 patients with newly diagnosed nonmetastatic (M0) NPC with N0 or 4 cm or less N1 disease (Ho's N-stage classification, 1978) were randomized to receive either conventional radiotherapy (Arm I, n = 82) or conventional/accelerated-hyperfractionated radiotherapy (Arm II, n = 77). Stratification was according to the T stage. The biologic effective dose (10 Grays) to the primary and the upper cervical lymphatics were 75.0 and 73.1 for Arm I and 84.4 and 77.2 for Arm II, respectively. Results: With comparable distribution among the T stages between the two arms, the free from local failure rate at 5 years after radiotherapy was not significantly different between the two arms (85.3%; 95% confidence interval, 77.2-93.4% for Arm I; and 88.9%; 95% confidence interval, 81.7-96.2% for Arm II). The two arms were also comparable in overall survival, relapse-free survival, and rates of distant metastasis and regional relapse. Conventional/accelerated-hyperfractionated radiotherapy was associated with significantly increased radiation-induced damage to the central nervous system (including temporal lobe, cranial nerves, optic nerve/chiasma, and brainstem/spinal cord) in Arm II. Although insignificant, radiation-induced cranial nerve(s) palsy (typically involving VIII-XII), trismus, neck soft tissue fibrosis, and hypopituiturism and hypothyroidism occurred more often in Arm II. In addition, the complications occurred at significantly shorter intervals after radiotherapy in Arm II. Conclusion: Accelerated hyperfractionation when used in conjunction with a two-dimensional radiotherapy planning technique, in this case the Ho's technique, resulted in increased radiation damage to the central

  9. Process control analysis of IMRT QA: implications for clinical trials

    International Nuclear Information System (INIS)

    Pawlicki, Todd; Rice, Roger K; Yoo, Sua; Court, Laurence E; McMillan, Sharon K; Russell, J Donald; Pacyniak, John M; Woo, Milton K; Basran, Parminder S; Boyer, Arthur L; Bonilla, Claribel

    2008-01-01

    The purpose of this study is two-fold: first is to investigate the process of IMRT QA using control charts and second is to compare control chart limits to limits calculated using the standard deviation (σ). Head and neck and prostate IMRT QA cases from seven institutions in both academic and community settings are considered. The percent difference between the point dose measurement in phantom and the corresponding result from the treatment planning system (TPS) is used for analysis. The average of the percent difference calculations defines the accuracy of the process and is called the process target. This represents the degree to which the process meets the clinical goal of 0% difference between the measurements and TPS. IMRT QA process ability defines the ability of the process to meet clinical specifications (e.g. 5% difference between the measurement and TPS). The process ability is defined in two ways: (1) the half-width of the control chart limits, and (2) the half-width of ±3σ limits. Process performance is characterized as being in one of four possible states that describes the stability of the process and its ability to meet clinical specifications. For the head and neck cases, the average process target across institutions was 0.3% (range: -1.5% to 2.9%). The average process ability using control chart limits was 7.2% (range: 5.3% to 9.8%) compared to 6.7% (range: 5.3% to 8.2%) using standard deviation limits. For the prostate cases, the average process target across the institutions was 0.2% (range: -1.8% to 1.4%). The average process ability using control chart limits was 4.4% (range: 1.3% to 9.4%) compared to 5.3% (range: 2.3% to 9.8%) using standard deviation limits. Using the standard deviation to characterize IMRT QA process performance resulted in processes being preferentially placed in one of the four states. This is in contrast to using control charts for process characterization where the IMRT QA processes were spread over three of the

  10. IMRT delivers lower radiation doses to dental structures than 3DRT in head and neck cancer patients

    International Nuclear Information System (INIS)

    Fregnani, Eduardo Rodrigues; Parahyba, Cláudia Joffily; Morais-Faria, Karina; Fonseca, Felipe Paiva; Ramos, Pedro Augusto Mendes; Moraes, Fábio Yone de; Conceição Vasconcelos, Karina Gondim Moutinho da; Menegussi, Gisela; Santos-Silva, Alan Roger; Brandão, Thais B.

    2016-01-01

    Radiotherapy (RT) is frequently used in the treatment of head and neck cancer, but different side-effects are frequently reported, including a higher frequency of radiation-related caries, what may be consequence of direct radiation to dental tissue. The intensity-modulated radiotherapy (IMRT) was developed to improve tumor control and decrease patient’s morbidity by delivering radiation beams only to tumor shapes and sparing normal tissue. However, teeth are usually not included in IMRT plannings and the real efficacy of IMRT in the dental context has not been addressed. Therefore, the aim of this study is to assess whether IMRT delivers lower radiation doses to dental structures than conformal 3D radiotherapy (3DRT). Radiation dose delivery to dental structures of 80 patients treated for head and neck cancers (oral cavity, tongue, nasopharynx and oropharynx) with IMRT (40 patients) and 3DRT (40 patients) were assessed by individually contouring tooth crowns on patients’ treatment plans. Clinicopathological data were retrieved from patients’ medical files. The average dose of radiation to teeth delivered by IMRT was significantly lower than with 3DRT (p = 0.007); however, only patients affected by nasopharynx and oral cavity cancers demonstrated significantly lower doses with IMRT (p = 0.012 and p = 0.011, respectively). Molars received more radiation with both 3DRT and IMRT, but the latter delivered significantly lower radiation in this group of teeth (p < 0.001), whereas no significant difference was found for the other dental groups. Maxillary teeth received lower doses than mandibular teeth, but only IMRT delivered significantly lower doses (p = 0.011 and p = 0.003). Ipsilateral teeth received higher doses than contralateral teeth with both techniques and IMRT delivered significantly lower radiation than 3DRT for contralateral dental structures (p < 0.001). IMRT delivered lower radiation doses to teeth than 3DRT, but only for some groups of patients and

  11. Dosimetry investigation of MOSFET for clinical IMRT dose verification.

    Science.gov (United States)

    Deshpande, Sudesh; Kumar, Rajesh; Ghadi, Yogesh; Neharu, R M; Kannan, V

    2013-06-01

    In IMRT, patient-specific dose verification is followed regularly at each centre. Simple and efficient dosimetry techniques play a very important role in routine clinical dosimetry QA. The MOSFET dosimeter offers several advantages over the conventional dosimeters such as its small detector size, immediate readout, immediate reuse, multiple point dose measurements. To use the MOSFET as routine clinical dosimetry system for pre-treatment dose verification in IMRT, a comprehensive set of experiments has been conducted, to investigate its linearity, reproducibility, dose rate effect and angular dependence for 6 MV x-ray beam. The MOSFETs shows a linear response with linearity coefficient of 0.992 for a dose range of 35 cGy to 427 cGy. The reproducibility of the MOSFET was measured by irradiating the MOSFET for ten consecutive irradiations in the dose range of 35 cGy to 427 cGy. The measured reproducibility of MOSFET was found to be within 4% up to 70 cGy and within 1.4% above 70 cGy. The dose rate effect on the MOSFET was investigated in the dose rate range 100 MU/min to 600 MU/min. The response of the MOSFET varies from -1.7% to 2.1%. The angular responses of the MOSFETs were measured at 10 degrees intervals from 90 to 270 degrees in an anticlockwise direction and normalized at gantry angle zero and it was found to be in the range of 0.98 ± 0.014 to 1.01 ± 0.014. The MOSFETs were calibrated in a phantom which was later used for IMRT verification. The measured calibration coefficients were found to be 1 mV/cGy and 2.995 mV/cGy in standard and high sensitivity mode respectively. The MOSFETs were used for pre-treatment dose verification in IMRT. Nine dosimeters were used for each patient to measure the dose in different plane. The average variation between calculated and measured dose at any location was within 3%. Dose verification using MOSFET and IMRT phantom was found to quick and efficient and well suited for a busy radiotherapy

  12. The inter- and intrafraction reproducibilities of three common IMRT delivery techniques

    International Nuclear Information System (INIS)

    Buckey, Courtney R.; Stathakis, Sotirios; Papanikolaou, Niko

    2010-01-01

    Purpose: Intensity modulated radiation therapy (IMRT) treatment delivery requires higher precision than conventional 3D treatment delivery because of the sensitivity of the resulting dose to small geometric misalignment of the modulated beamlets. The chosen treatment delivery technique will affect the treatment precision in different ways, based on the characteristics of the delivery method. Delivery using a multileaf collimator (MLC) can reduce treatment time and therapist workload, but typically requires a greater number of monitor units and the fields are prone to both systematic and random leaf positioning errors. An alternative to MLC-based fields, patient specific brass compensators, do not suffer from these leaf positioning errors. In our study, we set out to investigate which delivery method will provide the highest levels of dosimetric reproducibility and the minimum amount of interfraction variability. Methods: In our study, a seven field IMRT plan for a head and neck treatment was created using the Pinnacle 3 treatment planning system and the intensity maps for each field were obtained. The intensity maps of the fields were delivered with a Varian 2100C/D linear accelerator, using solid compensators and sliding window (SW) and step-and-shoot (SS) MLC segments. Three fields were selected from the seven-beam IMRT plan for comparison. Analysis was carried out using the MatriXX ion chamber array, radiochromic film, and Varian dynalog files. Results: Our results show that the error in MLC leaf positioning has no gantry angle dependence. The compensator and SW deliveries showed excellent agreement, even when stricter than usual gamma criteria were applied. However, we noted that under these strict conditions, the SS fields had at least ten times more pixels out of range than did the compensators. When using step-and-shoot MLC fields, it was observed that the increase in dose rate or the increase of MU/segment degrades the quality of the plan. Analysis of the

  13. Re-Planning for Compensator-Based IMRT with Original Compensators

    International Nuclear Information System (INIS)

    Zhang, Geoffrey; Feygelman, Vladimir; Stevens, Craig; Li Weiqi; Leuthold, Susan; Springett, Gregory; Hoffe, Sarah

    2011-01-01

    Compared with multileaf collimator (MLC)-based intensity-modulated radiotherapy (IMRT) for moving targets, compensator-based IMRT has advantages such as shorter beam-on time, fewer monitor units with potentially decreased secondary carcinogenesis risk, better optimization-to-deliverable dose conversion, and often better dose conformity. Some of the disadvantages include additional time for the compensators to be built and delivered, as well as extra cost. Patients undergoing treatment of abdominal cancers often experience weight loss. It would be necessary to account for this change in weight with a new plan and a second set of compensators. However, this would result in treatment delays and added costs. We have developed a method to re-plan the patient using the same set of compensators. Because the weight changes seen with the treatment of abdominal cancers are usually relatively small, a new 4D computed tomography (CT) acquired in the treatment position with markers on the original isocenter tattoos can be registered to the original planning scan. The contours of target volumes from the original scans are copied to the new scan after fusion. The original compensator set can be used together with a few field-in-field (FiF) beams defined by the MLC (or beams with cerrobend blocks for accelerators not equipped with a MLC). The weights of the beams with compensators are reduced so that the FiF or blocked beams can be optimized to mirror the original plan and dose distribution. Seven abdominal cancer cases are presented using this technique. The new plan on the new planning CT images usually has the same dosimetric quality as the original. The target coverage and dose uniformity are improved compared with the plan without FiF/block modification. Techniques combining additional FiF or blocked beams with the original compensators optimize the treatment plans when patients lose weight and save time and cost compared with generating plans with a new set of compensators.

  14. Retrospective analysis of 'gamma distribution' based IMRT QA criteria

    International Nuclear Information System (INIS)

    Wen, C.; Chappell, R.A.

    2010-01-01

    Full text: IMRT has been implemented into clinical practice at Royal Hobart Hospital (RHH) since mid 2006 for treating patients with Head and Neck (H and N) or prostate tumours. A local quality assurance (QA) acceptance criteria based on 'gamma distribution' for approving IMRT plan was developed and implemented in early 2007. A retrospective analysis of such criteria over 194 clinical cases will be presented. The RHH IMRT criteria was established with assumption that gamma distribution obtained through inter-comparison of 2 D dose maps between planned and delivered was governed by a positive-hail' normal distribution. A commercial system-MapCheck was used for 2 D dose map comparison with a built-in gamma analysis tool. Gamma distribution histogram was generated and recorded for all cases. By retrospectively analysing those distributions using curve fitting technique, a statistical gamma distribution can be obtained and evaluated. This analytical result can be used for future IMRT planing and treatment delivery. The analyses indicate that gamma distribution obtained through MapCheckTM is well under the normal distribution, particularly for prostate cases. The applied pass/fail criteria is not overly sensitive to identify 'false fails' but can be further tighten-up for smaller field while for larger field found in both H and N and prostate cases, the criteria was correctly applied. Non-uniform distribution of detectors in MapCheck and experience level of planners are two major factors to variation in gamma distribution among clinical cases. This criteria derived from clinical statistics is superior and more accurate than single-valued criteria for lMRT QA acceptance procedure. (author)

  15. A Method for Correcting IMRT Optimizer Heterogeneity Dose Calculations

    International Nuclear Information System (INIS)

    Zacarias, Albert S.; Brown, Mellonie F.; Mills, Michael D.

    2010-01-01

    Radiation therapy treatment planning for volumes close to the patient's surface, in lung tissue and in the head and neck region, can be challenging for the planning system optimizer because of the complexity of the treatment and protected volumes, as well as striking heterogeneity corrections. Because it is often the goal of the planner to produce an isodose plan with uniform dose throughout the planning target volume (PTV), there is a need for improved planning optimization procedures for PTVs located in these anatomical regions. To illustrate such an improved procedure, we present a treatment planning case of a patient with a lung lesion located in the posterior right lung. The intensity-modulated radiation therapy (IMRT) plan generated using standard optimization procedures produced substantial dose nonuniformity across the tumor caused by the effect of lung tissue surrounding the tumor. We demonstrate a novel iterative method of dose correction performed on the initial IMRT plan to produce a more uniform dose distribution within the PTV. This optimization method corrected for the dose missing on the periphery of the PTV and reduced the maximum dose on the PTV to 106% from 120% on the representative IMRT plan.

  16. There is no role for hyperfractionated radiotherapy in the management of children with newly diagnosed diffuse intrinsic brainstem tumors: results of a pediatric oncology group phase III trial comparing conventional vs. hyperfractionated radiotherapy

    International Nuclear Information System (INIS)

    Mandell, Lynda R.; Kadota, Richard; Freeman, Carolyn; Douglass, Edwin C.; Fontanesi, James; Cohen, Michael E.; Kovnar, Edward; Burger, Peter; Sanford, Robert A.; Kepner, James; Friedman, Henry; Kun, Larry E.

    1999-01-01

    Purpose: In June 1992, POG began accrual to a phase III study, POG-9239, designed to compare the time to disease progression, overall survival, and toxicities observed in children with newly diagnosed brainstem tumor treated with 100 mg/m 2 of infusional cisplatin and randomized to either conventional vs. hyperfractionated radiotherapy. Methods and Materials: Patients eligible for study were those between 3 and 21 years of age with previously untreated tumors arising in the pons. Histologic confirmation of diagnosis was not mandatory, provided that the clinical and MRI scan findings were typical for a diffusely infiltrating pontine lesion. Treatment consisted of a six-week course of local field radiotherapy with either once a day treatment of 180 cGy per fraction to a total dose of 5400 cGy (arm 1) or a twice a day regimen of 117 cGy per fraction to a total dose of 7020 cGy (the second of the three hyperfractionated dose escalation levels of POG-8495) (arm 2). Because of previously reported poor results with conventional radiotherapy alone, cisplatin was included as a potential radiosensitizer in an attempt to improve progression-free and ultimate survival rates. Based on results of the phase I cisplatin dose escalation trial, POG-9139, 100 mg/m 2 was chosen for this trial and was delivered by continuous infusion over a 120-hour period, beginning on the first day of radiotherapy and repeated during weeks 3 and 5. One hundred thirty eligible patients were treated on protocol, 66 on arm 1 and 64 on arm 2. Results: The results we report are from time of diagnosis through October 1997. For patients treated on arm 1, the median time to disease progression (defined as time to off study) was 6 months (range 2-15 months) and the median time to death 8.5 months (range 3-24 months); survival at 1 year was 30.9% and at 2 years, 7.1%. For patients treated on arm 2, the corresponding values were 5 months (range 1-12 months) and 8 months (range 1-23 months), with 1- and 2-year

  17. IMRT delivers lower radiation doses to dental structures than 3DRT in head and neck cancer patients.

    Science.gov (United States)

    Fregnani, Eduardo Rodrigues; Parahyba, Cláudia Joffily; Morais-Faria, Karina; Fonseca, Felipe Paiva; Ramos, Pedro Augusto Mendes; de Moraes, Fábio Yone; da Conceição Vasconcelos, Karina Gondim Moutinho; Menegussi, Gisela; Santos-Silva, Alan Roger; Brandão, Thais B

    2016-09-07

    Radiotherapy (RT) is frequently used in the treatment of head and neck cancer, but different side-effects are frequently reported, including a higher frequency of radiation-related caries, what may be consequence of direct radiation to dental tissue. The intensity-modulated radiotherapy (IMRT) was developed to improve tumor control and decrease patient's morbidity by delivering radiation beams only to tumor shapes and sparing normal tissue. However, teeth are usually not included in IMRT plannings and the real efficacy of IMRT in the dental context has not been addressed. Therefore, the aim of this study is to assess whether IMRT delivers lower radiation doses to dental structures than conformal 3D radiotherapy (3DRT). Radiation dose delivery to dental structures of 80 patients treated for head and neck cancers (oral cavity, tongue, nasopharynx and oropharynx) with IMRT (40 patients) and 3DRT (40 patients) were assessed by individually contouring tooth crowns on patients' treatment plans. Clinicopathological data were retrieved from patients' medical files. The average dose of radiation to teeth delivered by IMRT was significantly lower than with 3DRT (p = 0.007); however, only patients affected by nasopharynx and oral cavity cancers demonstrated significantly lower doses with IMRT (p = 0.012 and p = 0.011, respectively). Molars received more radiation with both 3DRT and IMRT, but the latter delivered significantly lower radiation in this group of teeth (p dental groups. Maxillary teeth received lower doses than mandibular teeth, but only IMRT delivered significantly lower doses (p = 0.011 and p = 0.003). Ipsilateral teeth received higher doses than contralateral teeth with both techniques and IMRT delivered significantly lower radiation than 3DRT for contralateral dental structures (p radiation doses to teeth than 3DRT, but only for some groups of patients and teeth, suggesting that this decrease was more likely due to the protection of

  18. Implementation of dosimetric quality control on IMRT and VMAT treatments in radiotherapy using diodes; Implementacion de control de calidad dosimetrico en tratamientos de IMRT y VMAT en radioterapia usando diodos

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, A.; Garcia, B.; Ramirez, J.; Marquina, J., E-mail: andres.gonzales@aliada.com.pe [ALIADA, Oncologia Integral, Av. Jose Galvez Barrenechea 1044, San Isidro, Lima 27 (Peru)

    2014-08-15

    To implement quality control of IMRT and VMAT treatments Rapid Arc radiotherapy using diode array. Were tested 90 patients with IMRT and VMAT Rapid Arc, comparing the planned dose to the dose administered, used the Map-Check-2 and Arc-Check of Sun Nuclear, they using the gamma factor for calculating and using comparison parameters 3% / 3m m. The statistic shows that the quality controls of the 90 patients analyzed, presented a percentage of diodes that pass the test between 96,7% and 100,0% of the irradiated diodes. Implemented in Clinical ALIADA Oncologia Integral, the method for quality control of IMRT and VMAT treatments Rapid Arc radiotherapy using diode array. (Author)

  19. Is ad-hoc plan adaptation based on 2-Step IMRT feasible?

    International Nuclear Information System (INIS)

    Bratengeier, Klaus; Polat, Buelent; Gainey, Mark; Grewenig, Patricia; Meyer, Juergen; Flentje, Michael

    2009-01-01

    Background: The ability of a geometry-based method to expeditiously adapt a '2-Step' step and shoot IMRT plan was explored. Both changes of the geometry of target and organ at risk have to be balanced. A retrospective prostate planning study was performed to investigate the relative benefits of beam segment adaptation to the changes in target and organ at risk coverage. Methods: Four patients with six planning cases with extraordinarily large deformations of rectum and prostate were chosen for the study. A 9-field IMRT plan (A) using 2-Step IMRT segments was planned on an initial CT study. The plan had to fulfil all the requirements of a conventional high-quality step and shoot IMRT plan. To adapt to changes of the anatomy in a further CT data set, three approaches were considered: the original plan with optimized isocentre position (B), a newly optimized plan (C) and the original plan, adapted using the 2-Step IMRT optimization rules (D). DVH parameters were utilized for quantification of plan quality: D 99 for the CTV and the central planning target volume (PTV), D 95 for an outer PTV, V 95 , V 80 and V 50 for rectum and bladder. Results: The adapted plan (D) achieved almost the same target coverage as the newly optimized plan (C). Target coverage for plan B was poor and for the organs at risk, the rectum V 80 was slightly increased. The volume with more than 95% of the target dose (V 95 ) was 1.5 ± 1.5 cm 3 for the newly optimized plan (C), compared to 2.2 ± 1.3 cm 3 for the original plan (A) and 7.2 ± 4.8 cm 3 (B) on the first and the second CT, respectively. The adapted plan resulted in 4.3 ± 2.1 cm 3 (D), an intermediate dose load to the rectum. All other parameters were comparable for the newly optimized and the adapted plan. Conclusions: The first results for adaptation of interfractional changes using the 2-Step IMRT algorithm are encouraging. The plans were superior to plans with optimized isocentre position and only marginally inferior to a newly

  20. Verification of patient position and delivery of IMRT by electronic portal imaging

    International Nuclear Information System (INIS)

    Fielding, Andrew L.; Evans, Philip M.; Clark, Catharine H.

    2004-01-01

    Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 2 deg. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam

  1. Dosimetric comparison of treatment techniques IMRT and VMAT for breast cancer

    International Nuclear Information System (INIS)

    Urbina, G. L.; Garcia, B. G.

    2015-10-01

    In this study the dosimetric distribution was compared in the different treatment techniques such as Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) in female patients with breast cancer with stage II-B and III-A, 6 cases (both calculated on VMAT and IMRT) were studied, comparison parameter that are taken into account are: compliance rate, homogeneity index, monitor units, volume dose 50 Gy (D-50%) and 5 Gy (D-5%) volume dose. Comparisons are made in primary tumor volume to optimize treatment in patients with breast cancer, with IMRT using Step, Shoot and VMAT Monte Carlo algorithm, in addition to the organs at risk; the concern to make this work is due to technological advances in radiotherapy and the application of new treatment techniques, that increase the accuracy allowing treatment dose climbing delivering a higher dose to the patient. (Author)

  2. Combined Adjuvant Radiochemotherapy With IMRT/XELOX Improves Outcome With Low Renal Toxicity in Gastric Cancer

    International Nuclear Information System (INIS)

    Boda-Heggemann, Judit; Hofheinz, Ralf-Dieter; Weiss, Christel; Mennemeyer, Philipp; Mai, Sabine K.; Hermes, Petra; Wertz, Hansjoerg; Post, Stefan; Massner, Bernd; Hieber, Udo; Hochhaus, Andreas; Wenz, Frederik; Lohr, Frank

    2009-01-01

    Objectives: Adjuvant radiochemotherapy improves survival of patients with advanced gastric cancer. We assessed in two sequential cohorts whether improved radiotherapy technique (IMRT) together with intensified chemotherapy improves outcome vs. conventional three-dimensional conformal radiotherapy (3D-CRT) and standard chemotherapy in these patients while maintaining or reducing renal toxicity. Materials and Methods: Sixty consecutive patients treated for gastric cancer either with 3D-CRT (n = 27) and IMRT (n = 33) were evaluated. More than 70% had undergone D2 resection. Although there was a slight imbalance in R0 status between cohorts, N+ status was balanced. Chemotherapy consisted predominantly of 5-fluorouracil/folinic acid (n = 36) in the earlier cohort and mostly of oxaliplatin/capecitabine (XELOX, n = 24) in the later cohort. Primary end points were overall survival (OS), disease-free survival (DFS), and renal toxicity based on creatinine levels. Results: Median follow-up (FU) of all patients in the 3D-CRT group was 18 months and in the IMRT group 22 months (median FU of surviving patients 67 months in the 3D-CRT group and 25 months in the IMRT group). Overall median survival (and DFS) were 18 (13) months in the 3D-CRT group and both not reached in the IMRT group (p = 0.0492 and 0.0216). Actuarial 2-year survival was 37% and 67% in the 3D-CRT and IMRT groups, respectively. No late renal toxicity >Grade 2 (LENT-SOMA scale) was observed in either cohort. Conclusion: When comparing sequentially treated patient cohorts with similar characteristics, OS and DFS improved with the use of IMRT and intensified chemotherapy without signs of increased renal toxicity.

  3. Micro ionization chamber dosimetry in IMRT verification: Clinical implications of dosimetric errors in the PTV

    International Nuclear Information System (INIS)

    Sanchez-Doblado, Francisco; Capote, Roberto; Rosello, Joan V.; Leal, Antonio; Lagares, Juan I.; Arrans, Rafael; Hartmann, Guenther H.

    2005-01-01

    Background and purpose: Absolute dose measurements for Intensity Modulated Radiotherapy (IMRT) beamlets is difficult due to the lack of lateral electron equilibrium. Recently we found that the absolute dosimetry in the penumbra region of the IMRT beamlet, can suffer from significant errors (Capote et al., Med Phys 31 (2004) 2416-2422). This work has the goal to estimate the error made when measuring the Planning Target Volume's (PTV) absolute dose by a micro ion chamber (μIC) in typical IMRT treatment. The dose error comes from the assumption that the dosimetric parameters determining the absolute dose are the same as for the reference conditions. Materials and Methods: Two IMRT treatment plans for common prostate carcinoma case, derived by forward and inverse optimisation, were considered. Detailed geometrical simulation of the μIC and the dose verification set-up was performed. The Monte Carlo (MC) simulation allows us to calculate the delivered dose to water and the dose delivered to the active volume of the ion chamber. However, the measured dose in water is usually derived from chamber readings assuming reference conditions. The MC simulation provides needed correction factors for ion chamber dosimetry in non reference conditions. Results: Dose calculations were carried out for some representative beamlets, a combination of segments and for the delivered IMRT treatments. We observe that the largest dose errors (i.e. the largest correction factors) correspond to the smaller contribution of the corresponding IMRT beamlets to the total dose delivered in the ionization chamber within PTV. Conclusion: The clinical impact of the calculated dose error in PTV measured dose was found to be negligible for studied IMRT treatments

  4. SU-E-T-105: An FMEA Survey of Intensity Modulated Radiation Therapy (IMRT) Step and Shoot Dose Delivery Failure Modes

    International Nuclear Information System (INIS)

    Faught, J Tonigan; Johnson, J; Stingo, F; Kry, S; Court, L; Balter, P; Followill, D

    2015-01-01

    Purpose: To assess the perception of TG-142 tolerance level dose delivery failures in IMRT and the application of FMEA process to this specific aspect of IMRT. Methods: An online survey was distributed to medical physicists worldwide that briefly described 11 different failure modes (FMs) covered by basic quality assurance in step- and-shoot IMRT at or near TG-142 tolerance criteria levels. For each FM, respondents estimated the worst case H&N patient percent dose error and FMEA scores for Occurrence, Detectability, and Severity. Demographic data was also collected. Results: 181 individual and three group responses were submitted. 84% were from North America. Most (76%) individual respondents performed at least 80% clinical work and 92% were nationally certified. Respondent medical physics experience ranged from 2.5–45 years (average 18 years). 52% of individual respondents were at least somewhat familiar with FMEA, while 17% were not familiar. Several IMRT techniques, treatment planning systems and linear accelerator manufacturers were represented. All FMs received widely varying scores ranging from 1–10 for occurrence, at least 1–9 for detectability, and at least 1–7 for severity. Ranking FMs by RPN scores also resulted in large variability, with each FM being ranked both most risky (1st ) and least risky (11th) by different respondents. On average MLC modeling had the highest RPN scores. Individual estimated percent dose errors and severity scores positively correlated (p<0.10) for each FM as expected. No universal correlations were found between the demographic information collected and scoring, percent dose errors, or ranking. Conclusion: FMs investigated overall were evaluated as low to medium risk, with average RPNs less than 110. The ranking of 11 FMs was not agreed upon by the community. Large variability in FMEA scoring may be caused by individual interpretation and/or experience, thus reflecting the subjective nature of the FMEA tool

  5. SU-C-BRD-03: Closing the Loop On Virtual IMRT QA

    International Nuclear Information System (INIS)

    Valdes, G; Scheuermann, R; Y, H C.; Olszanski, A; Bellerive, M; Solberg, T

    2015-01-01

    Purpose: To develop an algorithm that predicts a priori IMRT QA passing rates. Methods: 416 IMRT plans from all treatment sites were planned in Eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam linacs (Varian Medical Systems, Palo Alto, CA). The 3%/3mm and 2%/2mm local distance to agreement (DTA) were recorded during clinical operations using a commercial 2D diode array (MapCHECK 2, Sun Nuclear, Melbourne, FL). Each plan was characterized by 37 metrics that describe different failure modes between the calculated and measured dose. Machine-learning algorithms (MLAs) were trained to learn the relation between the plan characteristics and each passing rate. Minimization of the cross validated error, together with maximum a posteriori estimation (MAP), were used to choose the model parameters. Results: 3%/3mm local DTA can be predicted with an error smaller than 3% for 98% of the plans. For the remaining 2% of plans, the residual error was within 5%. For 2%/2mm local DTA passing rates, 96% percent of the plans were successfully predicted with an error smaller than 5%. All high-risk plans that failed the 2%/2mm local criteria were correctly identified by the algorithm. The most important metric to describe the passing rates was determined to be the MU per Gray (modulation factor). Conclusions: Logs files and independent dose calculations have been suggested as possible substitutes for measurement based IMRT QA. However, none of these methods answer the fundamental question of whether a plan can be delivered with a clinically acceptable error given the limitations of the linacs and the treatment planning system. Predicting the IMRT QA passing rates a priori closes that loop. For additional robustness, virtual IMRT QA can be combined with Linac QA and log file analysis to confirm appropriate delivery

  6. SU-C-BRD-03: Closing the Loop On Virtual IMRT QA

    Energy Technology Data Exchange (ETDEWEB)

    Valdes, G; Scheuermann, R; Y, H C.; Olszanski, A; Bellerive, M; Solberg, T [University of Pennsylvania, Philadelphia, PA (United States)

    2015-06-15

    Purpose: To develop an algorithm that predicts a priori IMRT QA passing rates. Methods: 416 IMRT plans from all treatment sites were planned in Eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam linacs (Varian Medical Systems, Palo Alto, CA). The 3%/3mm and 2%/2mm local distance to agreement (DTA) were recorded during clinical operations using a commercial 2D diode array (MapCHECK 2, Sun Nuclear, Melbourne, FL). Each plan was characterized by 37 metrics that describe different failure modes between the calculated and measured dose. Machine-learning algorithms (MLAs) were trained to learn the relation between the plan characteristics and each passing rate. Minimization of the cross validated error, together with maximum a posteriori estimation (MAP), were used to choose the model parameters. Results: 3%/3mm local DTA can be predicted with an error smaller than 3% for 98% of the plans. For the remaining 2% of plans, the residual error was within 5%. For 2%/2mm local DTA passing rates, 96% percent of the plans were successfully predicted with an error smaller than 5%. All high-risk plans that failed the 2%/2mm local criteria were correctly identified by the algorithm. The most important metric to describe the passing rates was determined to be the MU per Gray (modulation factor). Conclusions: Logs files and independent dose calculations have been suggested as possible substitutes for measurement based IMRT QA. However, none of these methods answer the fundamental question of whether a plan can be delivered with a clinically acceptable error given the limitations of the linacs and the treatment planning system. Predicting the IMRT QA passing rates a priori closes that loop. For additional robustness, virtual IMRT QA can be combined with Linac QA and log file analysis to confirm appropriate delivery.

  7. Dosimetric evaluation of the response of the TLD-100 dosemeters in the IMRT technique by 'Step and Shoot'; Evaluacion dosimetrica de la respuesta de los dosimetros TLD-100 en la tecnica de IMRT por 'Step and Shoot'

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, J. [Fundacion Clinica Valle del Lili, A.A. 020338, Cali (Colombia); Benavides, S.O. [Depto. de Fisica, Universidad del Valle, A.A. 25360, Cali (Colombia)

    2005-07-01

    We show the results of the dosimetry response of LiF thermoluminescent crystals: TLD-100, where they were radiated in a linear accelerator Siemens Primus Hl using the Intensity Modulated Radiation Therapy (IMRT) by step and shoot technique. Previous to the crystals calibration and response evaluation, the acceptation procedures recommended by the TG-53 protocol for validation of the technique were carried out. The planning system utilized was the Theraplan Plus 3.8, using the algorithm of Pencil Kernel. The register and verification system was Lantis 5.2. The response curve of dose versus charge was obtained from the readings of the TLD in a Harshaw 3500. The crystals were radiated in a Bench- Marck phantom with doses previously determined by using ionization chambers for square radiation fields, in a beam with a 0.68 TPR20,10 corresponding to 6 MV of energy. We compare the response of these through of radiation of segmented fields in a Anthropomorphic phantom and the calculated doses by the planning system. The results obtained in the crystals response show deviations less than 5 % between the measured dose and the calculated dose in the zones of low gradient. It allows its implementation like routine control of quality by IMRT. (Author)

  8. Analysis of Local Control in Patients Receiving IMRT for Resected Pancreatic Cancers

    International Nuclear Information System (INIS)

    Yovino, Susannah; Maidment, Bert W.; Herman, Joseph M.; Pandya, Naimish; Goloubeva, Olga; Wolfgang, Chris; Schulick, Richard; Laheru, Daniel; Hanna, Nader; Alexander, Richard; Regine, William F.

    2012-01-01

    Purpose: Intensity-modulated radiotherapy (IMRT) is increasingly incorporated into therapy for pancreatic cancer. A concern regarding this technique is the potential for geographic miss and decreased local control. We analyzed patterns of first failure among patients treated with IMRT for resected pancreatic cancer. Methods and Materials: Seventy-one patients who underwent resection and adjuvant chemoradiation for pancreas cancer are included in this report. IMRT was used for all to a median dose of 50.4 Gy. Concurrent chemotherapy was 5-FU–based in 72% of patients and gemcitabine-based in 28%. Results: At median follow-up of 24 months, 49/71 patients (69%) had failed. The predominant failure pattern was distant metastases in 35/71 patients (49%). The most common site of metastases was the liver. Fourteen patients (19%) developed locoregional failure in the tumor bed alone in 5 patients, regional nodes in 4 patients, and concurrently with metastases in 5 patients. Median overall survival (OS) was 25 months. On univariate analysis, nodal status, margin status, postoperative CA 19-9 level, and weight loss during treatment were predictive for OS. On multivariate analysis, higher postoperative CA19-9 levels predicted for worse OS on a continuous basis (p < 0.01). A trend to worse OS was seen among patients with more weight loss during therapy (p = 0.06). Patients with positive nodes and positive margins also had significantly worse OS (HR for death 2.8, 95% CI 1.1–7.5; HR for death 2.6, 95% CI 1.1–6.2, respectively). Grade 3-4 nausea and vomiting was seen in 8% of patients. Late complication of small bowel obstruction occurred in 4 (6%) patients. Conclusions: This is the first comprehensive report of patterns of failure among patients treated with adjuvant IMRT for pancreas cancer. IMRT was not associated with an increase in local recurrences in our cohort. These data support the use of IMRT in the recently activated EORTC/US Intergroup/RTOG 0848 adjuvant

  9. Esophagus and contralateral lung-sparing IMRT for locally advanced lung cancer in the community hospital setting

    Directory of Open Access Journals (Sweden)

    Johnny eKao

    2015-06-01

    Full Text Available Background: The optimal technique for performing lung IMRT remains poorly defined. We hypothesize that improved dose distributions associated with normal tissue sparing IMRT can allow for safe dose escalation resulting in decreased acute and late toxicity. Methods: We performed a retrospective analysis of 82 consecutive lung cancer patients treated with curative intent from 1/10 to 9/14. From 1/10 to 4/12, 44 patients were treated with the community standard of 3-dimensional conformal radiotherapy or IMRT without specific esophagus or contralateral lung constraints (standard RT. From 5/12 to 9/14, 38 patients were treated with normal tissue-sparing IMRT with selective sparing of contralateral lung and esophagus. The study endpoints were dosimetry, toxicity and overall survival.Results: Despite higher mean prescribed radiation doses in the normal tissue-sparing IMRT cohort (64.5 Gy vs. 60.8 Gy, p=0.04, patients treated with normal tissue-sparing IMRT had significantly lower lung V20, V10, V5, mean lung, maximum esophagus and mean esophagus doses compared to patients treated with standard RT (p≤0.001. Patients in the normal tissue-sparing IMRT group had reduced acute grade ≥3 esophagitis (0% vs. 11%, p<0.001, acute grade ≥2 weight loss (2% vs. 16%, p=0.04, late grade ≥2 pneumonitis (7% vs. 21%, p=0.02. The 2-year overall survival was 52% with normal tissue-sparing IMRT arm compared to 28% for standard RT (p=0.015.Conclusion: These data provide proof of principle that suboptimal radiation dose distributions are associated with significant acute and late lung and esophageal toxicity that may result in hospitalization or even premature mortality. Strict attention to contralateral lung and esophageal dose volume constraints are feasible in the community hospital setting without sacrificing disease control.

  10. Influence of intra-fractional breathing movement in step-and-shoot IMRT

    International Nuclear Information System (INIS)

    Schaefer, M; Muenter, M W; Thilmann, C; Sterzing, F; Haering, P; Combs, S E; Debus, J

    2004-01-01

    Efforts have been made to extend the application of intensity-modulated radiotherapy to a variety of organs. One of the unanswered questions is whether breathing-induced organ motion may lead to a relevant over- or underdosage, e.g., in treatment plans for the irradiation of lung cancer. Theoretical considerations have been made concerning the different kinds of IMRT but there is still a lack of experimental data. We examined 18 points in a fraction of a clinical treatment plan of a NSCLC delivered in static IMRT with a new phantom and nine ionization chambers. Measurements were performed at a speed of 12 and 16 breathing cycles per minute. The dose differences between static points and moving target points ranged between -2.4% and +5.5% (mean: +0.2%, median: -0.1%) when moving with 12 cycles min -1 and between -3.6% and +5.0% (mean: -0.4%, median: -0.6%) when moving with 16 cycles min -1 . All differences of measurements with and without movements were below 5%, with one exception. In conclusion, our results underline that at least in static IMRT breathing effects (concerning target dose coverage) due to interplay effects between collimator leaf movement and target movement are of secondary importance and will not reduce the clinical value of IMRT in the step-and-shoot technique for irradiation of thoracic targets. (note)

  11. Computational model to simulate the interplay effect in dynamic IMRT delivery

    International Nuclear Information System (INIS)

    Yoganathan, S A; Maria Das, K J; Kumar, Shaleen

    2014-01-01

    The purpose of this study was to develop and experimentally verify a patient specific model for simulating the interplay effect in a DMLC based IMRT delivery. A computational model was developed using MATLAB program to incorporate the interplay effect in a 2D beams eye view fluence of dynamic IMRT fields. To simulate interplay effect, the model requires two inputs: IMRT field (DMLC file with dose rate and MU) and the patient specific respiratory motion. The interplay between the DMLC leaf motion and target was simulated for three lung patients. The target trajectory data was acquired using RPM system during the treatment simulation. The model was verified experimentally for the same patients using Imatrix 2D array device placed over QUASAR motion platform in CL2100 linac. The simulated fluences and measured fluences were compared with the TPS generated static fluence (no motion) using an in-house developed gamma evaluation program (2%/2mm). The simulated results were well within agreement with the measured. Comparison of the simulated and measured fluences with the TPS static fluence resulted 55.3% and 58.5% pixels passed the gamma criteria. A patient specific model was developed and validated for simulating the interplay effect in the dynamic IMRT delivery. This model can be clinically used to quantify the dosimetric uncertainty due to the interplay effect prior to the treatment delivery.

  12. IMRT QA: Selecting gamma criteria based on error detection sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Steers, Jennifer M. [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 and Physics and Biology in Medicine IDP, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095 (United States); Fraass, Benedick A., E-mail: benedick.fraass@cshs.org [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 (United States)

    2016-04-15

    Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose

  13. Six years of experience in the planning and verification of the IMRT dynamics with portal dosimetry; Seis anos de expereincia en la planificacion y verificacion de la IMRT dinamica con portal dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Molina Lopez, M. Y.; Pardo Perez, E.; Ruiz Maqueda, S.; Castro Novais, J.; Diaz Gavela, A. A.

    2013-07-01

    The objective of this study is the make a review of the method of verification of the IMRT throughout the 6 years of functioning of the service of-radiophysics and radiology protection, analyzing the parameters of each field evaluation to the 718 made IMRT during this period. (Author)

  14. An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT

    International Nuclear Information System (INIS)

    Hugo, Geoffrey D.; Agazaryan, Nzhde; Solberg, Timothy D.

    2002-01-01

    A respiratory gating system has been developed based on a commercial patient positioning system. The purpose of this study is to investigate the ability of the gating system to reproduce normal, nongated IMRT operation and to quantify the errors produced by delivering a nongated IMRT treatment onto a moving target. A moving phantom capable of simultaneous two-dimensional motion was built, and an analytical liver motion function was used to drive the phantom. Studies were performed to assess the effect of gating window size and choice of delivery method (segmented and dynamic multileaf collimation). Additionally, two multiple field IMRT cases were delivered to quantify the error in gated and nongated IMRT with motion. Dosimetric error between nonmoving and moving deliveries is related to gating window size. By reducing the window size, the error can be reduced. Delivery error can be reduced for both dynamic and segmented delivery with gating. For the implementation of dynamic IMRT delivery in this study, dynamic delivery was found to generate larger delivery errors than segmented delivery in most cases studied. For multiple field IMRT delivery, the largest errors were generated in regions where high field modulation was present parallel to the axis of motion. Gating was found to reduce these large errors to clinically acceptable levels

  15. IMRT and radiation protection in the prostate cancer therapy; IMRT e a protecao radiologica no tratamento do cancer de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Helena C.; Silva, Andre R.M.; Oliveira, Claudia F.M., E-mail: andrerichard88@bol.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil)

    2015-07-01

    This study aims to specify the technological advances that IMRT presents relative to other traditional radiotherapy, particularly to conformal radiotherapy three dimensional (3D-TCR) and benefits compared to the side effects caused by from treatment of radiotherapy.

  16. Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT and Arc technique for esophageal carcinoma

    International Nuclear Information System (INIS)

    Martin, Spencer; Chen, Jeff Z.; Rashid Dar, A.; Yartsev, Slav

    2011-01-01

    Purpose: To compare radiotherapy treatment plans for mid- and distal-esophageal cancer with primary involvement of the gastroesophageal (GE) junction using a novel IMRT and Arc technique (IMRT and Arc), helical tomotherapy (HT), and RapidArc (RA1 and RA2). Methods and materials: Eight patients treated on HT for locally advanced esophageal cancer with radical intent were re-planned for RA and IMRT and Arc. RA plans employed single and double arcs (RA1 and RA2, respectively), while IMRT and Arc plans had four fixed-gantry IMRT fields and a conformal arc. Dose-volume histogram statistics, dose uniformity, and dose homogeneity were analyzed to compare treatment plans. Results: RA2 plans showed significant improvement over RA1 plans in terms of OAR dose and PTV dose uniformity and homogeneity. HT plan provided best dose uniformity (p = 0.001) and dose homogeneity (p = 0.002) to planning target volume (PTV), while IMRT and Arc and RA2 plans gave lowest dose to lungs among four radiotherapy techniques with acceptable PTV dose coverage. Mean V 10 of the lungs was significantly reduced by the RA2 plans compared to IMRT and Arc (40.3%, p = 0.001) and HT (66.2%, p 15 of the lungs for the RA2 plans also showed significant improvement over the IMRT and Arc (25.2%, p = 0.042) and HT (34.8%, p = 0.027) techniques. These improvements came at the cost of higher doses to the heart volume compared to HT and IMRT and Arc techniques. Mean lung dose (MLD) for the IMRT and Arc technique (21.2 ± 5.0% of prescription dose) was significantly reduced compared to HT (26.3%, p = 0.004), RA1 (23.3%, p = 0.028), and RA2 (23.2%, p = 0.017) techniques. Conclusion: The IMRT and Arc technique is a good option for treating esophageal cancer with thoracic involvement. It achieved optimal low dose to the lungs and heart with acceptable PTV coverage. HT is a good option for treating esophageal cancer with little thoracic involvement as it achieves superior dose conformality and uniformity. The RA2

  17. Validation of the implementation of IMRT with three dosimetric methods of independent verification

    International Nuclear Information System (INIS)

    Tortosa Oliver, R. A.; Chinillach ferrando, N.; Alonso Arrizabalaga, S.; Campayo Esteban, J. M.; Morales Marco, J. C.; Soler Catalan, P.; Andreu Martinez, F. J.

    2013-01-01

    The TG119 is a simple and clear framework to verify the implementation of IMRT technique in a radiotherapy service. Verifications of this document recommended tests conducted with the three dosimetric methods listed above, allow to affirm that our Center is within the margins of tolerance considered suitable in the TG119 for the clinical implementation of IMRT. (Author)

  18. Dosimetric evaluation of the response of the TLD-100 dosemeters in the IMRT technique by 'Step and Shoot'

    International Nuclear Information System (INIS)

    Vasquez, J.; Benavides, S.O.

    2005-01-01

    We show the results of the dosimetry response of LiF thermoluminescent crystals: TLD-100, where they were radiated in a linear accelerator Siemens Primus Hl using the Intensity Modulated Radiation Therapy (IMRT) by step and shoot technique. Previous to the crystals calibration and response evaluation, the acceptation procedures recommended by the TG-53 protocol for validation of the technique were carried out. The planning system utilized was the Theraplan Plus 3.8, using the algorithm of Pencil Kernel. The register and verification system was Lantis 5.2. The response curve of dose versus charge was obtained from the readings of the TLD in a Harshaw 3500. The crystals were radiated in a Bench- Marck phantom with doses previously determined by using ionization chambers for square radiation fields, in a beam with a 0.68 TPR20,10 corresponding to 6 MV of energy. We compare the response of these through of radiation of segmented fields in a Anthropomorphic phantom and the calculated doses by the planning system. The results obtained in the crystals response show deviations less than 5 % between the measured dose and the calculated dose in the zones of low gradient. It allows its implementation like routine control of quality by IMRT. (Author)

  19. A mathematical framework for virtual IMRT QA using machine learning.

    Science.gov (United States)

    Valdes, G; Scheuermann, R; Hung, C Y; Olszanski, A; Bellerive, M; Solberg, T D

    2016-07-01

    It is common practice to perform patient-specific pretreatment verifications to the clinical delivery of IMRT. This process can be time-consuming and not altogether instructive due to the myriad sources that may produce a failing result. The purpose of this study was to develop an algorithm capable of predicting IMRT QA passing rates a priori. From all treatment, 498 IMRT plans sites were planned in eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam Linacs. 3%/3 mm local dose/distance-to-agreement (DTA) was recorded using a commercial 2D diode array. Each plan was characterized by 78 metrics that describe different aspects of their complexity that could lead to disagreements between the calculated and measured dose. A Poisson regression with Lasso regularization was trained to learn the relation between the plan characteristics and each passing rate. Passing rates 3%/3 mm local dose/DTA can be predicted with an error smaller than 3% for all plans analyzed. The most important metrics to describe the passing rates were determined to be the MU factor (MU per Gy), small aperture score, irregularity factor, and fraction of the plan delivered at the corners of a 40 × 40 cm field. The higher the value of these metrics, the worse the passing rates. The Virtual QA process predicts IMRT passing rates with a high likelihood, allows the detection of failures due to setup errors, and it is sensitive enough to detect small differences between matched Linacs.

  20. Node-positive left-sided breast cancer. Does VMAT improve treatment plan quality with respect to IMRT?

    Energy Technology Data Exchange (ETDEWEB)

    Pasler, M.; Bartelt, S.; Lutterbach, J. [Lake Constance Radiation Oncology Center Singen, Friedrichshafen (Germany); Georg, D. [Medical University Vienna/AKH Wien, Vienna (Austria). Dept. of Radiooncology; Medical University Vienna (Austria). Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology

    2013-05-15

    Purpose: The aim of the present work was to explore plan quality and dosimetric accuracy of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for lymph node-positive left-sided breast cancer. Methods: VMAT and IMRT plans were generated with the Pinnacle{sup 3} V9.0 treatment planning system for 10 lymph node-positive left-sided breast cancer patients. VMAT plans were created using a single arc and IMRT was performed with 4 beams using 6, 10, and 15 MV photon energy, respectively. Plans were evaluated both manually and automatically using ArtiView trademark. Dosimetric plan verification was performed with a 2D ionization chamber array placed in a full scatter phantom. Results: Photon energy had no significant influence on plan quality for both VMAT and IMRT. Large variability in low doses to the heart was found due to patient anatomy (range V{sub 5} {sub Gy} 26.5-95 %). Slightly more normal tissue dose was found for VMAT (e.g., V{sub Tissue30%} = 22 %) than in IMRT (V{sub Tissue30%} = 18 %). The manual and ArtiView trademark plan evaluation coincided very accurately for most dose metrics (difference < 1 %). In VMAT, 96.7 % of detector points passed the 3 %/3 mm gamma criterion; marginally better accuracy was found in IMRT (98.3 %). Conclusion: VMAT for node-positive left-sided breast cancer retains target homogeneity and coverage when compared to IMRT and allows maximum doses to organs at risk to be reduced. ArtiView trademark enables fast and accurate plan evaluation. (orig.)

  1. Theoretical and practical model for implementing intensity modulated radiotherapy (IMRT) based on openness in head and neck tumors

    International Nuclear Information System (INIS)

    Napoles Morales, Misleidy; Yanes Lopez, Yaima; Ascension, Yudith; Alfonso La Guardia, Rodolfo; Calderon, Carlos

    2009-01-01

    Certain requirements have been internationally recommended for the transition from radiation therapy (3D-CRT) to intensity modulated radiation therapy (IMRT). They have been filling in clinical practice in the physical, dosimetry and quality of treatment. Prior to the implementation of IMRT have been developed preclinical will proceed according to the treatment planning techniques in the real images of patients, validating the rationale for the transition from the point of view and radiobiological dosimetry. The comparison was based on a group of patients eligible for IMRT, which were actually treated with 3D-CRT. IMRT plans were designed and applied to virtually the same patients, simulating the IMRT treatment. The prescribed dose and fractionation were similar in both techniques, to be able to compare radiobiology. The results show the rationality of IMRT in terms of reducing complications and the possibility of scaling doses in the PTV. Were used Dose Volume Histograms (HDV) obtained from the dosimetric calculations for radiobiological evaluation of treatment plans, letting through a software: 'Albireo Target' version 4.0.1.2008 calculate the equivalent uniform dose (EUD) for tumor and organs of risks (OAR) and tumor control probability (TCP) and the likelihood of damage to healthy tissue (NTCP). The results obtained with IMRT plans were more significant than with 3D-CRT especially in terms of EUD for organs at risk and NTCP. These results allow us to create the definitive basis for the implementation of IMRT in our environment. (Author)

  2. Development of a quality control system in intensity modulated radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Souza, Roberto Salomon de; Braz, Delson

    2013-01-01

    The more complex the technique of radiotherapy is, the more refined the quality control must be. The technique of Intensity Modulated Radiotherapy (IMRT) is one of the technological innovations that gained space in the whole worlds in the last decade whose parameters of quality control are not fully established yet. The present work developed a phantom for quality control in IMRT to be implemented in the routine of the Radiotherapy Quality Control Program (PQRT) of the Brazilian National Cancer Institute (INCa). The device consists of a block formed by several polystyrene slice with TDLs and radiochromic film inserted. It should be sent (or taken) to the Program participating institutions to be irradiated under certain conditions and then be returned to the PQRT., where the discrepancy degree between the planned treatment and those effectively delivered will be evaluated. The system was validated through the test cases and the pilot program preformed in nine radiotherapy centers that perform IMRT in the southeast region of Brazil. (author)

  3. Is IMRT Superior or Inferior to 3DCRT in Radiotherapy for NSCLC? A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Xingsheng Hu

    Full Text Available There are no adequate data to determine whether intensity-modulated radiotherapy (IMRT is superior to three-dimensional conformal radiotherapy (3DCRT in the treatment of non-small cell lung cancer (NSCLC. This meta-analysis was conducted to compare the clinical outcomes of IMRT and 3DCRT in the treatment of NSCLC.No exclusions were made based on types of study design. We performed a literature search in PubMed, EMBASE and the Cochrane library databases from their inceptions to April 30, 2015. The overall survival (OS and relative risk (RR of radiation pneumonitis and radiation oesophagitis were evaluated. Two authors independently assessed the methodological quality and extracted data. Publication bias was evaluated by funnel plot using Egger's test results.From the literature search, 10 retrospective studies were collected, and of those, 5 (12,896 patients were selected for OS analysis, 4 (981 patients were selected for radiation pneumonitis analysis, and 4 (1339 patients were selected for radiation oesophagitis analysis. Cox multivariate proportional hazards models revealed that 3DCRT and IMRT had similar OS (HR = 0.96, P = 0.477 but that IMRT reduced the incidence of grade 2 radiation pneumonitis (RR = 0.74, P = 0.009 and increased the incidence of grade 3 radiation oesophagitis (RR = 2.47, P = 0.000.OS of IMRT for NSCLC is not inferior to that of 3DCRT, but IMRT significantly reduces the risk of radiation pneumonitis and increases the risk of radiation oesophagitis compared to 3DCRT.

  4. IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119

    Energy Technology Data Exchange (ETDEWEB)

    Ezzell, Gary A.; Burmeister, Jay W.; Dogan, Nesrin [Department of Radiation Oncology, Mayo Clinic Scottsdale, 5777 East Mayo Boulevard, MCSB Concourse, Phoenix, Arizona 89054 (United States); and others

    2009-11-15

    AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit=|mean|+1.96{sigma}. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.

  5. Quality correction factors of composite IMRT beam deliveries: Theoretical considerations

    International Nuclear Information System (INIS)

    Bouchard, Hugo

    2012-01-01

    Purpose: In the scope of intensity modulated radiation therapy (IMRT) dosimetry using ionization chambers, quality correction factors of plan-class-specific reference (PCSR) fields are theoretically investigated. The symmetry of the problem is studied to provide recommendable criteria for composite beam deliveries where correction factors are minimal and also to establish a theoretical limit for PCSR delivery k Q factors. Methods: The concept of virtual symmetric collapsed (VSC) beam, being associated to a given modulated composite delivery, is defined in the scope of this investigation. Under symmetrical measurement conditions, any composite delivery has the property of having a k Q factor identical to its associated VSC beam. Using this concept of VSC, a fundamental property of IMRT k Q factors is demonstrated in the form of a theorem. The sensitivity to the conditions required by the theorem is thoroughly examined. Results: The theorem states that if a composite modulated beam delivery produces a uniform dose distribution in a volume V cyl which is symmetric with the cylindrical delivery and all beams fulfills two conditions in V cyl : (1) the dose modulation function is unchanged along the beam axis, and (2) the dose gradient in the beam direction is constant for a given lateral position; then its associated VSC beam produces no lateral dose gradient in V cyl , no matter what beam modulation or gantry angles are being used. The examination of the conditions required by the theorem lead to the following results. The effect of the depth-dose gradient not being perfectly constant with depth on the VSC beam lateral dose gradient is found negligible. The effect of the dose modulation function being degraded with depth on the VSC beam lateral dose gradient is found to be only related to scatter and beam hardening, as the theorem holds also for diverging beams. Conclusions: The use of the symmetry of the problem in the present paper leads to a valuable theorem showing

  6. A silicon strip detector dose magnifying glass for IMRT dosimetry

    International Nuclear Information System (INIS)

    Wong, J. H. D.; Carolan, M.; Lerch, M. L. F.; Petasecca, M.; Khanna, S.; Perevertaylo, V. L.; Metcalfe, P.; Rosenfeld, A. B.

    2010-01-01

    Purpose: Intensity modulated radiation therapy (IMRT) allows the delivery of escalated radiation dose to tumor while sparing adjacent critical organs. In doing so, IMRT plans tend to incorporate steep dose gradients at interfaces between the target and the organs at risk. Current quality assurance (QA) verification tools such as 2D diode arrays, are limited by their spatial resolution and conventional films are nonreal time. In this article, the authors describe a novel silicon strip detector (CMRP DMG) of high spatial resolution (200 μm) suitable for measuring the high dose gradients in an IMRT delivery. Methods: A full characterization of the detector was performed, including dose per pulse effect, percent depth dose comparison with Farmer ion chamber measurements, stem effect, dose linearity, uniformity, energy response, angular response, and penumbra measurements. They also present the application of the CMRP DMG in the dosimetric verification of a clinical IMRT plan. Results: The detector response changed by 23% for a 390-fold change in the dose per pulse. A correction function is derived to correct for this effect. The strip detector depth dose curve agrees with the Farmer ion chamber within 0.8%. The stem effect was negligible (0.2%). The dose linearity was excellent for the dose range of 3-300 cGy. A uniformity correction method is described to correct for variations in the individual detector pixel responses. The detector showed an over-response relative to tissue dose at lower photon energies with the maximum dose response at 75 kVp nominal photon energy. Penumbra studies using a Varian Clinac 21EX at 1.5 and 10.0 cm depths were measured to be 2.77 and 3.94 mm for the secondary collimators, 3.52 and 5.60 mm for the multileaf collimator rounded leaf ends, respectively. Point doses measured with the strip detector were compared to doses measured with EBT film and doses predicted by the Philips Pinnacle treatment planning system. The differences were 1.1%

  7. From analytic inversion to contemporary IMRT optimization: radiation therapy planning revisited from a mathematical perspective.

    Science.gov (United States)

    Censor, Yair; Unkelbach, Jan

    2012-04-01

    In this paper we look at the development of radiation therapy treatment planning from a mathematical point of view. Historically, planning for Intensity-Modulated Radiation Therapy (IMRT) has been considered as an inverse problem. We discuss first the two fundamental approaches that have been investigated to solve this inverse problem: Continuous analytic inversion techniques on one hand, and fully-discretized algebraic methods on the other hand. In the second part of the paper, we review another fundamental question which has been subject to debate from the beginning of IMRT until the present day: The rotation therapy approach versus fixed angle IMRT. This builds a bridge from historic work on IMRT planning to contemporary research in the context of Intensity-Modulated Arc Therapy (IMAT). Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Verification of PTV margins for IMRT prostate cancer using EPID; Verificacao das margens de PTV para IMRT de cancer de prostata utilizando EPID

    Energy Technology Data Exchange (ETDEWEB)

    Leidens, Matheus; Santos, Romulo R.; Estacio, Daniela R. [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil). Hospital Sao Lucas. Servico de Fisica Medica; Silva, Ana Maria Marques da, E-mail: matheus_leidens@hotmail.com [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil). Faculdade de Fisica

    2014-12-15

    The aim of this work is to present the results of a strategy to define the PTV margins for patients with prostate cancer treated with IMRT technique, due to geometrical uncertainties associated with the planned placement. 341 images of 31 patients in supine position, before applying the fractions, were obtained using an EPID attached to a linear accelerator, where only setup errors were studied. The displacements were analyzed in relation to the AP (antero-posterior), SI (superior-inferior) and LR (left-right) directions. The distribution pattern of systematic displacement deviation values were 0.12 cm, 0.06 cm, 0.02 cm and the standard deviation of the distribution of random deviations was 0.62 cm, 0.53 cm, and 0.24 cm in the AP, SI and LR directions, respectively. Data evaluation, according to Stroom and Heijmen’s method, suggests that PTV margins should be 0.66 cm in the AP direction, 0.49 cm in the SI direction and 0.20 cm in the LR direction. These data show a high reproducibility in the positioning of patients, given by a method for the correction of planned relative to the bony anatomy checked with the EPID position. (author)

  9. Comparative dosimetric analysis of IMRT and VMAT (RapidArc in brain, head and neck, breast and prostate malignancies

    Directory of Open Access Journals (Sweden)

    Mirza Athar Ali

    2015-03-01

    Full Text Available Purpose: Intensity modulated radiotherapy (IMRT in the recent past has established itself as a gold standard for organs at risk (OAR sparing, target coverage and dose conformity. With the advent of a rotational treatment technology such as volumetric modulated arc therapy (VMAT, an inter-comparison is warranted to address the advantages and disadvantages of each technique. Methods: Twenty patients were selected retrospectively from our patient database. Sites included were brain, head and neck, chest wall, and prostate, with five patients for each site. For all the selected patients, both the IMRT and VMAT treatment plans were generated. Plan comparison was done in terms of OAR dose, dose homogeneity index (HI, dose conformity index (CI, target coverage, low isodose volumes, monitor units (MUs, and treatment time.Results: The VMAT showed better sparing of “parotids minus planning target volume (PTV”, spinal cord and head of femur as compared to the IMRT. The lung V40 for VMAT was lower, whereas the lung V10, contralateral lung mean dose, contralateral breast mean dose and mean body dose were lower with IMRT for chest wall cases. Both the VMAT and IMRT achieved comparable HI except for the brain site, where IMRT scored over VMAT. The CI achieved by the IMRT and VMAT were similar except for chest wall cases, whereas the VMAT achieved better dose conformity. The target coverage was comparable with both the plans. The VMAT clearly scored over IMRT in terms of average MUs (486 versus 812 respectively and average treatment time (2.54 minutes versus 5.54 minutes per treatment session. Conclusion: The VMAT (RapidArc has a potential to generate treatment plans for various anatomical sites which are comparable with the corresponding IMRT plans in terms of OAR sparing and plan quality parameters. The VMAT significantly reduces treatment time as compared to the IMRT, thus VMAT can increase the throughput of a busy radiotherapy department.

  10. Evaluation of intrafraction patient movement for CNS and head and neck IMRT

    International Nuclear Information System (INIS)

    Kim, Siyong; Akpati, Hilary C.; Kielbasa, Jerrold E.; Li, Jonathan G.; Liu, Chihray; Amdur, Robert J.; Palta, Jatinder R.

    2004-01-01

    Intrafraction patient motion is much more likely in intensity-modulated radiation therapy (IMRT) than in conventional radiotherapy primarily due to longer beam delivery times in IMRT treatment. In this study, we evaluated the uncertainty of intrafraction patient displacement in CNS and head and neck IMRT patients. Immobilization is performed in three steps: (1) the patient is immobilized with thermoplastic facemask, (2) the patient displacement is monitored using a commercial stereotactic infrared IR camera (ExacTrac, BrainLab) during treatment, and (3) repositioning is carried out as needed. The displacement data were recorded during beam-on time for the entire treatment duration for 5 patients using the camera system. We used the concept of cumulative time versus patient position uncertainty, referred to as an uncertainty time histogram (UTH), to analyze the data. UTH is a plot of the accumulated time during which a patient stays within the corresponding movement uncertainty. The University of Florida immobilization procedure showed an effective immobilization capability for CNS and head and neck IMRT patients by keeping the patient displacement less than 1.5 mm for 95% of treatment time (1.43 mm for 1, and 1.02 mm for 1, and less than 1.0 mm for 3 patients). The maximum displacement was 2.0 mm

  11. Independent calculation-based verification of IMRT plans using a 3D dose-calculation engine

    International Nuclear Information System (INIS)

    Arumugam, Sankar; Xing, Aitang; Goozee, Gary; Holloway, Lois

    2013-01-01

    Independent monitor unit verification of intensity-modulated radiation therapy (IMRT) plans requires detailed 3-dimensional (3D) dose verification. The aim of this study was to investigate using a 3D dose engine in a second commercial treatment planning system (TPS) for this task, facilitated by in-house software. Our department has XiO and Pinnacle TPSs, both with IMRT planning capability and modeled for an Elekta-Synergy 6 MV photon beam. These systems allow the transfer of computed tomography (CT) data and RT structures between them but do not allow IMRT plans to be transferred. To provide this connectivity, an in-house computer programme was developed to convert radiation therapy prescription (RTP) files as generated by many planning systems into either XiO or Pinnacle IMRT file formats. Utilization of the technique and software was assessed by transferring 14 IMRT plans from XiO and Pinnacle onto the other system and performing 3D dose verification. The accuracy of the conversion process was checked by comparing the 3D dose matrices and dose volume histograms (DVHs) of structures for the recalculated plan on the same system. The developed software successfully transferred IMRT plans generated by 1 planning system into the other. Comparison of planning target volume (TV) DVHs for the original and recalculated plans showed good agreement; a maximum difference of 2% in mean dose, − 2.5% in D95, and 2.9% in V95 was observed. Similarly, a DVH comparison of organs at risk showed a maximum difference of +7.7% between the original and recalculated plans for structures in both high- and medium-dose regions. However, for structures in low-dose regions (less than 15% of prescription dose) a difference in mean dose up to +21.1% was observed between XiO and Pinnacle calculations. A dose matrix comparison of original and recalculated plans in XiO and Pinnacle TPSs was performed using gamma analysis with 3%/3 mm criteria. The mean and standard deviation of pixels passing

  12. Beam angle selection for intensity-modulated radiotherapy (IMRT) treatment of unresectable pancreatic cancer: are noncoplanar beam angles necessary?

    Science.gov (United States)

    Chang, D S; Bartlett, G K; Das, I J; Cardenes, H R

    2013-09-01

    External beam radiation therapy with concurrent chemotherapy (CRT) is widely used for the treatment of unresectable pancreatic cancer. Noncoplanar (NCP) 3D conformal radiotherapy (3DCRT) and coplanar (CP) IMRT have been reported to lower the radiation dose to organs at risk (OARs). The purpose of this article is to examine the utility of noncoplanar beam angles in IMRT for the management of pancreatic cancer. Sixteen patients who were treated with CRT for unresectable adenocarcinoma of the pancreatic head or neck were re-planned using CP and NCP beams in 3DCRT and IMRT with the Varian Eclipse treatment planning system. Compared to CP IMRT, NCP IMRT had similar target coverage with slightly increased maximum point dose, 5,799 versus 5,775 cGy (p = 0.008). NCP IMRT resulted in lower mean kidney dose, 787 versus 1,210 cGy (p kidney dose, but did not improve other dose-volume criteria. The use of NCP beam angles is preferred only in patients with risk factors for treatment-related kidney dysfunction.

  13. Dosimetric Comparison Between 3DCRT and IMRT Using Different Multileaf Collimators in the Treatment of Brain Tumors

    International Nuclear Information System (INIS)

    Ding Meisong; Newman, Francis M.S.; Chen Changhu; Stuhr, Kelly; Gaspar, Laurie E.

    2009-01-01

    We investigated the differences between 3-dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT), and the impact of collimator leaf-width on IMRT plans for the treatment of nonspherical brain tumors. Eight patients treated by 3DCRT with Novalis were selected. We developed 3 IMRT plans with different multileaf collimators (Novalis m3, Varian MLC-120, and Varian MLC-80) with the same treatment margins, number of beams, and gantry positions as in the 3DCRT treatment plans. Treatment planning utilized the BrainLAB treatment planning system. For each patient, the dose constraints and optimization parameters remained identical for all plans. The heterogeneity index, the percentage target coverage, critical structures, and normal tissue volumes receiving 50% of the prescription dose were calculated to compare the dosimetric difference. Equivalent uniform dose (EUD) and tumor control probability (TCP) were also introduced to evaluate the radiobiological effect for different plans. We found that IMRT significantly improved the target dose homogeneity compared to the 3DCRT. However, IMRT showed the same radiobiological effect as 3DCRT. For the brain tumors adjacent to (or partially overlapping with) critical structures, IMRT dramatically spared the volume of the critical structures to be irradiated. In IMRT plans, the smaller collimator leaf width could reduce the volume of critical structures irradiated to the 50% level for those partially overlapping with the brain tumors. For relatively large and spherical brain tumors, the smaller collimator leaf widths give no significant benefit

  14. Phase I dose escalating trial of hyperfractionated pre-operative chemoradiation for locally advanced rectal cancer

    International Nuclear Information System (INIS)

    Movsas, Benjamin; Hanlon, Alexandra L.; Lanciano, Rachelle; Scher, Richard M.; Weiner, Louis M.; Sigurdson, Elin R.; Hoffman, John P.; Eisenberg, Burton L.; Cooper, Harry S.; Provins, Susan; Coia, Lawrence R.

    1998-01-01

    Purpose: To determine the acute toxicity, post-operative complications, pathologic response and extent of downstaging to high dose pre-operative radiation using a hyperfractionated radiation boost and concurrent chemotherapy in a prospective Phase I trial. Materials and Methods: To be eligible for this study, patients had to have adenocarcinoma of the rectum less than 12 cm from the anal verge with either Stage T4 or T3 but greater than 4 cm or greater than 40% of the bowel circumference. All patients received 45 Gy pelvic radiation (1.8 Gy per fraction). Subsequent radiation was given to the region of the gross tumor with a 2 cm margin. This 'boost' treatment was given at 1.2 Gy twice daily to a total dose of 54.6 Gy for Level I, 57 Gy for Level II, and 61.8 Gy for Level III. 5-FU was given at 1g/m 2 over 24 hours for a four day infusion during the first and sixth weeks of radiation, with the second course concurrent with the hyperfractionated radiation. Surgical resection was carried out 4-6 weeks following completion of chemoradiation (in curative cases) and additional adjuvant chemotherapy consisting of 5-FU and Leucovorin was given for an additional 4 monthly cycles Days 1 through 5 beginning four weeks post surgery. Results: Twenty-seven patients, age 40-82 (median 61), completed the initial course of chemoradiation and are included in the analysis of toxicity. The median follow-up is 27 months (range 8-68). Eleven patients were treated to a dose of 54.6 Gy, nine patients to 57 Gy, and seven patients to 61.8 Gy. Twenty-one patients had T3 tumors, and six patients T4 tumors. Grade III acute toxicity from chemoradiation included proctitis (5 patients), dermatitis (9), diarrhea (five), leukopenia (1), cardiac (1). Grade IV toxicities included one patient with diarrhea (on dose Level I) and one patient (on dose Level III) with cardiac toxicity (unrelated to radiation). Surgical resection consisted of abdominal perineal resection in 16 and low anterior resection

  15. MVP Chemotherapy and Hyperfractionated Radiotherapy for Stage III Unresectable Non-Small Cell Lung Cancer - Randomized for maintenance Chemotherapy vs. Observation; Preliminary Report-

    International Nuclear Information System (INIS)

    Choi, Euk Kyung; Chang, Hye Sook; Suh, Cheol Won

    1991-01-01

    To evaluate the effect of MVP chemotherapy and hyperfractionated radiotherapy in Stage III unresectable non small cell lung cancer (NSCLC), authors have conducted a prospective randomized study since January 1991. Stage IIIa or IIIb unresectable NSCLC patients were treated with hyperfractionated radiotherapy (120 cGy/fx BID) up to 6500 cGY following 3 cycles of induction MVP (Mitomycin C 6 mg/m 2 , vinblastine 6 mg/m 2 , Cisplatin 60 mg/m 2 ) and randomized for either observation or 3 cycles of maintenance MVP chemotherapy. Until August 1991, 18 patients were registered to this study. 4 cases were stage IIIa and 14 were stage IIIb. Among 18 cases 2 were lost after 2 cycles of chemotherapy, and 16 were analyzed for this preliminary report. The response rate of induction chemotherapy was 62.5%; partial response, 50% and minimal response, 12.5%. Residual tumor of the one partial responder was completely disappeared after radiotherapy. Among 6 cases who were progressed during induction chemotherapy, 4 of them were also progressed after radiotherapy. All patients were tolerated BID radiotherapy without definite increase of acute complications, compared with conventional radiotherapy group. But at the time of this report, one patient expired in two month after the completion of the radiotherapy because of treatment related complication. Although the longer follow up is needed, authors are encouraged with higher response rate and acceptable toxicity of this treatment. Authors believe that this study is worthwhile to continue

  16. Adjuvant IMRT/XELOX radiochemotherapy improves long-term overall- and disease-free survival in advanced gastric cancer

    International Nuclear Information System (INIS)

    Boda-Heggemann, J.; Schneider, V.; Weiss, C.

    2013-01-01

    Purpose: In a retrospective analysis, adjuvant intensity-modulated radiation therapy (IMRT) combined with modern chemotherapy improved advanced gastric cancer survival rates compared to a combination of three-dimensional conformal radiation therapy (3D-CRT) and conventional chemotherapy. We report on the long-term outcomes of two consecutive patient cohorts that were treated with either IMRT and intensive chemotherapy, or 3D-CRT and conventional chemotherapy. Patients and methods: Between 2001 and 2008, 65 consecutive gastric cancer patients received either 3D-CRT (n = 27) or IMRT (n = 38) following tumor resection. Chemotherapy comprised predominantly 5-fluorouracil/folinic acid (5-FU/FA) in the earlier cohort and capecitabine plus oxaliplatin (XELOX) in the latter. The primary endpoints were overall survival (OS) and disease-free survival (DFS). Results: Median OS times were 18 and 43 months in the 3D-CRT and IMRT groups, respectively (p = 0.0602). Actuarial 5-year OS rates were 26 and 47 %, respectively. Within the IMRT group, XELOX gave better results than 5-FU/FA in terms of OS, but this difference was not statistically significant. The primary cause of death in both groups was distant metastasis. Median DFS times were 14 and 35 months in the 3D-CRT and IMRT groups, respectively (p = 0.0693). Actuarial 5-year DFS rates were 22 and 44 %, respectively. Among patients receiving 5-FU/FA, DFS tended to be better in the IMRT group, but this was not statistically significant. A similar analysis for the XELOX group was not possible as 3D-CRT was almost never used to treat these patients. No late toxicity exceeding grade 3 or secondary tumors were observed. Conclusion: After a median follow-up period of over 5 years, OS and DFS were improved in the IMRT/XELOX treated patients compared to the 3D-CRT/5-FU/FA group. Long-term observation revealed no clinical indications of therapy-induced secondary tumors or renal toxicity. (orig.)

  17. Adjuvant IMRT/XELOX radiochemotherapy improves long-term overall- and disease-free survival in advanced gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Boda-Heggemann, J.; Schneider, V. [Heidelberg Univ., Universitaetsmedizin Mannheim (Germany). Dept. of Radiation Oncology; Weiss, C. [Heidelberg Univ., Universitaetsmedizin Mannheim (Germany). Dept. of Biomathematics and Medical Statistics] [and others

    2013-05-15

    Purpose: In a retrospective analysis, adjuvant intensity-modulated radiation therapy (IMRT) combined with modern chemotherapy improved advanced gastric cancer survival rates compared to a combination of three-dimensional conformal radiation therapy (3D-CRT) and conventional chemotherapy. We report on the long-term outcomes of two consecutive patient cohorts that were treated with either IMRT and intensive chemotherapy, or 3D-CRT and conventional chemotherapy. Patients and methods: Between 2001 and 2008, 65 consecutive gastric cancer patients received either 3D-CRT (n = 27) or IMRT (n = 38) following tumor resection. Chemotherapy comprised predominantly 5-fluorouracil/folinic acid (5-FU/FA) in the earlier cohort and capecitabine plus oxaliplatin (XELOX) in the latter. The primary endpoints were overall survival (OS) and disease-free survival (DFS). Results: Median OS times were 18 and 43 months in the 3D-CRT and IMRT groups, respectively (p = 0.0602). Actuarial 5-year OS rates were 26 and 47 %, respectively. Within the IMRT group, XELOX gave better results than 5-FU/FA in terms of OS, but this difference was not statistically significant. The primary cause of death in both groups was distant metastasis. Median DFS times were 14 and 35 months in the 3D-CRT and IMRT groups, respectively (p = 0.0693). Actuarial 5-year DFS rates were 22 and 44 %, respectively. Among patients receiving 5-FU/FA, DFS tended to be better in the IMRT group, but this was not statistically significant. A similar analysis for the XELOX group was not possible as 3D-CRT was almost never used to treat these patients. No late toxicity exceeding grade 3 or secondary tumors were observed. Conclusion: After a median follow-up period of over 5 years, OS and DFS were improved in the IMRT/XELOX treated patients compared to the 3D-CRT/5-FU/FA group. Long-term observation revealed no clinical indications of therapy-induced secondary tumors or renal toxicity. (orig.)

  18. PET/CT Staging Followed by Intensity-Modulated Radiotherapy (IMRT) Improves Treatment Outcome of Locally Advanced Pharyngeal Carcinoma: a matched-pair comparison

    International Nuclear Information System (INIS)

    Rothschild, Sacha; Studer, Gabriela; Seifert, Burkhardt; Huguenin, Pia; Glanzmann, Christoph; Davis, J Bernard; Lütolf, Urs M; Hany, Thomas F; Ciernik, I Frank

    2007-01-01

    Impact of non-pharmacological innovations on cancer cure rates is difficult to assess. It remains unclear, whether outcome improves with 2- [18-F]-fluoro-2-deoxyglucose-positron emission tomography and integrated computer tomography (PET/CT) and intensity-modulated radiotherapy (IMRT) for curative treatment of advanced pharyngeal carcinoma. Forty five patients with stage IVA oro- or hypopharyngeal carcinoma were staged with an integrated PET/CT and treated with definitive chemoradiation with IMRT from 2002 until 2005. To estimate the impact of PET/CT with IMRT on outcome, a case-control analysis on all patients with PET/CT and IMRT was done after matching with eighty six patients treated between 1991 and 2001 without PET/CT and 3D-conformal radiotherapy with respect to gender, age, stage, grade, and tumor location with a ratio of 1:2. Median follow-up was eighteen months (range, 6–49 months) for the PET/CT-IMRT group and twenty eight months (range, 1–168 months) for the controls. PET/CT and treatment with IMRT improved cure rates compared to patients without PET/CT and IMRT. Overall survival of patients with PET/CT and IMRT was 97% and 91% at 1 and 2 years respectively, compared to 74% and 54% for patients without PET/CT or IMRT (p = 0.002). The event-free survival rate of PET/CT-IMRT group was 90% and 80% at 1 and 2 years respectively, compared to 72% and 56% in the control group (p = 0.005). PET/CT in combination with IMRT and chemotherapy for pharyngeal carcinoma improve oncological therapy of pharyngeal carcinomas. Long-term follow-up is needed to confirm these findings

  19. SU-F-T-256: 4D IMRT Planning Using An Early Prototype GPU-Enabled Eclipse Workstation

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, A; Modiri, A; Sawant, A [University of Maryland in Baltimore, Baltimore, MD (United States); Svatos, M [Varian Medical Systems, Palo Alto, CA (United States)

    2016-06-15

    Purpose: True 4D IMRT planning, based on simultaneous spatiotemporal optimization has been shown to significantly improve plan quality in lung radiotherapy. However, the high computational complexity associated with such planning represents a significant barrier to widespread clinical deployment. We introduce an early prototype GPU-enabled Eclipse workstation for inverse planning. To our knowledge, this is the first GPUintegrated Eclipse system demonstrating the potential for clinical translation of GPU computing on a major commercially-available TPS. Methods: The prototype system comprised of four NVIDIA Tesla K80 GPUs, with a maximum processing capability of 8.5 Tflops per K80 card. The system architecture consisted of three key modules: (i) a GPU-based inverse planning module using a highly-parallelizable, swarm intelligence-based global optimization algorithm, (ii) a GPU-based open-source b-spline deformable image registration module, Elastix, and (iii) a CUDA-based data management module. For evaluation, aperture fluence weights in an IMRT plan were optimized over 9 beams,166 apertures and 10 respiratory phases (14940 variables) for a lung cancer case (GTV = 95 cc, right lower lobe, 15 mm cranio-caudal motion). Sensitivity of the planning time and memory expense to parameter variations was quantified. Results: GPU-based inverse planning was significantly accelerated compared to its CPU counterpart (36 vs 488 min, for 10 phases, 10 search agents and 10 iterations). The optimized IMRT plan significantly improved OAR sparing compared to the original internal target volume (ITV)-based clinical plan, while maintaining prescribed tumor coverage. The dose-sparing improvements were: Esophagus Dmax 50%, Heart Dmax 42% and Spinal cord Dmax 25%. Conclusion: Our early prototype system demonstrates that through massive parallelization, computationally intense tasks such as 4D treatment planning can be accomplished in clinically feasible timeframes. With further

  20. SU-F-T-256: 4D IMRT Planning Using An Early Prototype GPU-Enabled Eclipse Workstation

    International Nuclear Information System (INIS)

    Hagan, A; Modiri, A; Sawant, A; Svatos, M

    2016-01-01

    Purpose: True 4D IMRT planning, based on simultaneous spatiotemporal optimization has been shown to significantly improve plan quality in lung radiotherapy. However, the high computational complexity associated with such planning represents a significant barrier to widespread clinical deployment. We introduce an early prototype GPU-enabled Eclipse workstation for inverse planning. To our knowledge, this is the first GPUintegrated Eclipse system demonstrating the potential for clinical translation of GPU computing on a major commercially-available TPS. Methods: The prototype system comprised of four NVIDIA Tesla K80 GPUs, with a maximum processing capability of 8.5 Tflops per K80 card. The system architecture consisted of three key modules: (i) a GPU-based inverse planning module using a highly-parallelizable, swarm intelligence-based global optimization algorithm, (ii) a GPU-based open-source b-spline deformable image registration module, Elastix, and (iii) a CUDA-based data management module. For evaluation, aperture fluence weights in an IMRT plan were optimized over 9 beams,166 apertures and 10 respiratory phases (14940 variables) for a lung cancer case (GTV = 95 cc, right lower lobe, 15 mm cranio-caudal motion). Sensitivity of the planning time and memory expense to parameter variations was quantified. Results: GPU-based inverse planning was significantly accelerated compared to its CPU counterpart (36 vs 488 min, for 10 phases, 10 search agents and 10 iterations). The optimized IMRT plan significantly improved OAR sparing compared to the original internal target volume (ITV)-based clinical plan, while maintaining prescribed tumor coverage. The dose-sparing improvements were: Esophagus Dmax 50%, Heart Dmax 42% and Spinal cord Dmax 25%. Conclusion: Our early prototype system demonstrates that through massive parallelization, computationally intense tasks such as 4D treatment planning can be accomplished in clinically feasible timeframes. With further

  1. Hyperfractionated stereotactic reirradiation for recurrent head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cvek, Jakub; Knybel, Lukas; Skacelikova, Eva; Otahal, Bretislav; Molenda, Lukas; Feltl, David [University Hospital Ostrava, Department of Oncology, Ostrava (Czech Republic); Stransky, Jiri; Res, Oldrich [University Hospital Ostrava, Department of Maxilofacial Surgery, Ostrava (Czech Republic); Matousek, Petr; Zelenik, Karol [University Hospital Ostrava, Department of Otolaryngology, Ostrava (Czech Republic)

    2016-01-15

    The goal of this work was to evaluate the efficacy and toxicity of hyperfractionated stereotactic reirradiation (re-RT) as a treatment for inoperable, recurrent, or second primary head and neck squamous cell cancer (HNSCC) that is not suitable for systemic treatment. Forty patients with recurrent or second primary HNSCC were included in this study. The patients had a median gross tumor volume of 76 ml (range 14-193 ml) and a previous radiotherapy dose greater than 60 Gy. Treatment was designed to cover 95 % of the planning target volume (PTV, defined as gross tumor volume [GTV] + 3 mm to account for microscopic spreading, with no additional set-up margin) with the prescribed dose (48 Gy in 16 fractions b.i.d.). Treatment was administered twice daily with a minimum 6 h gap. Uninvolved lymph nodes were not irradiated. Treatment was completed as planned for all patients (with median duration of 11 days, range 9-14 days). Acute toxicity was evaluated using the RTOG/EORTC scale. A 37 % incidence of grade 3 mucositis was observed, with recovery time of ≤ 4 weeks for all of these patients. Acute skin toxicity was never observed to be higher than grade 2. Late toxicity was also evaluated according to the RTOG/EORTC scale. Mandible radionecrosis was seen in 4 cases (10 %); however, neither carotid blowout syndrome nor other grade 4 late toxicity occurred. One-year overall survival (OS) and local progression-free survival (L-PFS) were found to be 33 and 44 %, respectively. Performance status and GTV proved to be significant prognostic factors regarding local control and survival. Hyperfractionated stereotactic re-RT is a reasonable treatment option for patients with recurrent/second primary HNSCC who were previously exposed to high-dose irradiation and who are not candidates for systemic treatment or hypofractionation. (orig.) [German] Ziel der Studie war es, die Effektivitaet und Toxizitaet der hyperfraktionierten akzelerierten stereotaktischen Wiederbestrahlung (re

  2. Total dural irradiation: RapidArc versus static-field IMRT: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Paul J., E-mail: paulj.kelly@hse.ie [Department of Radiation Oncology, Dana Farber/Brigham and Women' s Cancer Center, Harvard Medical School, Boston, MA (United States); Mannarino, Edward; Lewis, John Henry; Baldini, Elizabeth H.; Hacker, Fred L. [Department of Radiation Oncology, Dana Farber/Brigham and Women' s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2012-07-01

    The purpose of this study was to compare conventional fixed-gantry angle intensity-modulated radiation therapy (IMRT) with RapidArc for total dural irradiation. We also hypothesize that target volume-individualized collimator angles may produce substantial normal tissue sparing when planning with RapidArc. Five-, 7-, and 9-field fixed-gantry angle sliding-window IMRT plans were generated for comparison with RapidArc plans. Optimization and normal tissue constraints were constant for all plans. All plans were normalized so that 95% of the planning target volume (PTV) received at least 100% of the dose. RapidArc was delivered using 350 Degree-Sign clockwise and counterclockwise arcs. Conventional collimator angles of 45 Degree-Sign and 315 Degree-Sign were compared with 90 Degree-Sign on both arcs. Dose prescription was 59.4 Gy in 33 fractions. PTV metrics used for comparison were coverage, V{sub 107}%, D1%, conformality index (CI{sub 95}%), and heterogeneity index (D{sub 5}%-D{sub 95}%). Brain dose, the main challenge of this case, was compared using D{sub 1}%, Dmean, and V{sub 5} Gy. Dose to optic chiasm, optic nerves, globes, and lenses was also compared. The use of unconventional collimator angles (90 Degree-Sign on both arcs) substantially reduced dose to normal brain. All plans achieved acceptable target coverage. Homogeneity was similar for RapidArc and 9-field IMRT plans. However, heterogeneity increased with decreasing number of IMRT fields, resulting in unacceptable hotspots within the brain. Conformality was marginally better with RapidArc relative to IMRT. Low dose to brain, as indicated by V5Gy, was comparable in all plans. Doses to organs at risk (OARs) showed no clinically meaningful differences. The number of monitor units was lower and delivery time was reduced with RapidArc. The case-individualized RapidArc plan compared favorably with the 9-field conventional IMRT plan. In view of lower monitor unit requirements and shorter delivery time, Rapid

  3. Dosimetric verification of IMRT plans

    International Nuclear Information System (INIS)

    Bulski, W.; Cheimicski, K.; Rostkowska, J.

    2012-01-01

    Intensity modulated radiotherapy (IMRT) is a complex procedure requiring proper dosimetric verification. IMRT dose distributions are characterized by steep dose gradients which enable to spare organs at risk and allow for an escalation of the dose to the tumor. They require large number of radiation beams (sometimes over 10). The fluence measurements for individual beams are not sufficient for evaluation of the total dose distribution and to assure patient safety. The methods used at the Centre of Oncology in Warsaw are presented. In order to measure dose distributions in various cross-sections the film dosimeters were used (radiographic Kodak EDR2 films and radiochromic Gafchromic EBT films). The film characteristics were carefully examined. Several types of tissue equivalent phantoms were developed. A methodology of comparing measured dose distributions against the distributions calculated by treatment planning systems (TPS) was developed and tested. The tolerance level for this comparison was set at 3% difference in dose and 3 mm in distance to agreement. The so called gamma formalism was used. The results of these comparisons for a group of over 600 patients are presented. Agreement was found in 87 % of cases. This film dosimetry methodology was used as a benchmark to test and validate the performance of commercially available 2D and 3D matrices of detectors (ionization chambers or diodes). The results of these validations are also presented. (authors)

  4. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans

    International Nuclear Information System (INIS)

    Stapleton, S; Zavgorodni, S; Popescu, I A; Beckham, W A

    2005-01-01

    The fluence-convolution method for incorporating random set-up errors (RSE) into the Monte Carlo treatment planning dose calculations was previously proposed by Beckham et al, and it was validated for open field radiotherapy treatments. This study confirms the applicability of the fluence-convolution method for dynamic intensity modulated radiotherapy (IMRT) dose calculations and evaluates the impact of set-up uncertainties on a clinical IMRT dose distribution. BEAMnrc and DOSXYZnrc codes were used for Monte Carlo calculations. A sliding window IMRT delivery was simulated using a dynamic multi-leaf collimator (DMLC) transport model developed by Keall et al. The dose distributions were benchmarked for dynamic IMRT fields using extended dose range (EDR) film, accumulating the dose from 16 subsequent fractions shifted randomly. Agreement of calculated and measured relative dose values was well within statistical uncertainty. A clinical seven field sliding window IMRT head and neck treatment was then simulated and the effects of random set-up errors (standard deviation of 2 mm) were evaluated. The dose-volume histograms calculated in the PTV with and without corrections for RSE showed only small differences indicating a reduction of the volume of high dose region due to set-up errors. As well, it showed that adequate coverage of the PTV was maintained when RSE was incorporated. Slice-by-slice comparison of the dose distributions revealed differences of up to 5.6%. The incorporation of set-up errors altered the position of the hot spot in the plan. This work demonstrated validity of implementation of the fluence-convolution method to dynamic IMRT Monte Carlo dose calculations. It also showed that accounting for the set-up errors could be essential for correct identification of the value and position of the hot spot

  5. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans

    Science.gov (United States)

    Stapleton, S.; Zavgorodni, S.; Popescu, I. A.; Beckham, W. A.

    2005-02-01

    The fluence-convolution method for incorporating random set-up errors (RSE) into the Monte Carlo treatment planning dose calculations was previously proposed by Beckham et al, and it was validated for open field radiotherapy treatments. This study confirms the applicability of the fluence-convolution method for dynamic intensity modulated radiotherapy (IMRT) dose calculations and evaluates the impact of set-up uncertainties on a clinical IMRT dose distribution. BEAMnrc and DOSXYZnrc codes were used for Monte Carlo calculations. A sliding window IMRT delivery was simulated using a dynamic multi-leaf collimator (DMLC) transport model developed by Keall et al. The dose distributions were benchmarked for dynamic IMRT fields using extended dose range (EDR) film, accumulating the dose from 16 subsequent fractions shifted randomly. Agreement of calculated and measured relative dose values was well within statistical uncertainty. A clinical seven field sliding window IMRT head and neck treatment was then simulated and the effects of random set-up errors (standard deviation of 2 mm) were evaluated. The dose-volume histograms calculated in the PTV with and without corrections for RSE showed only small differences indicating a reduction of the volume of high dose region due to set-up errors. As well, it showed that adequate coverage of the PTV was maintained when RSE was incorporated. Slice-by-slice comparison of the dose distributions revealed differences of up to 5.6%. The incorporation of set-up errors altered the position of the hot spot in the plan. This work demonstrated validity of implementation of the fluence-convolution method to dynamic IMRT Monte Carlo dose calculations. It also showed that accounting for the set-up errors could be essential for correct identification of the value and position of the hot spot.

  6. Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Rawlinson, J. Alan; Islam, Mohammad K.; Galbraith, Duncan M.

    2002-01-01

    The increased beam-on times which characterize intensity-modulated radiation therapy (IMRT) could lead to an increase in the dose received by radiation therapists due to induced activity. To examine this, gamma ray spectrometry was used to identify the major isotopes responsible for activation at a representative location in the treatment room of an 18 MV accelerator (Varian Clinac 21EX). These were found to be 28 Al, 56 Mn, and 24 Na. The decay of the dose rate measured at this location following irradiation was analyzed in terms of the known half-lives to yield saturation dose rates of 9.6, 12.4, and 6.2 μSv/h, respectively. A formalism was developed to estimate activation dose (μSv/week) due to successive patient irradiation cycles, characterized by the number of 18 MV fractions per week, F, the number of MU per fraction, M, the in-room time between fractions, t d (min), and the treatment delivery time t r ' (min). The results are represented by the sum of two formulas, one for the dose from 28 Al≅1.8x10 -3 F M (1-e -0.3t r ' )/t r ' and one for the dose from the other isotopes ≅1.1x10 -6 F 1.7 Mt d . For conventional therapy doses are about 60 μ Sv/week for an 18 MV workload of 60 000 MU/week. Irradiation for QA purposes can significantly increase the dose. For IMRT as currently practiced, lengthy treatment delivery times limit the number of fractions that can be delivered per week and hence limit the dose to values similar to those in conventional therapy. However for an IMRT regime designed to maximize patient throughput, doses up to 330 μSv/week could be expected. To reduce dose it is recommended that IMRT treatments should be delivered at energies lower than 18 MV, that in multienergy IMRT, high-energy treatments should be scheduled in the latter part of the day, and that equipment manufacturers should strive to minimize activation in the design of high-energy accelerators

  7. Implementation of dosimetric quality control on IMRT and VMAT treatments in radiotherapy using diodes

    International Nuclear Information System (INIS)

    Gonzales, A.; Garcia, B.; Ramirez, J.; Marquina, J.

    2014-08-01

    To implement quality control of IMRT and VMAT treatments Rapid Arc radiotherapy using diode array. Were tested 90 patients with IMRT and VMAT Rapid Arc, comparing the planned dose to the dose administered, used the Map-Check-2 and Arc-Check of Sun Nuclear, they using the gamma factor for calculating and using comparison parameters 3% / 3m m. The statistic shows that the quality controls of the 90 patients analyzed, presented a percentage of diodes that pass the test between 96,7% and 100,0% of the irradiated diodes. Implemented in Clinical ALIADA Oncologia Integral, the method for quality control of IMRT and VMAT treatments Rapid Arc radiotherapy using diode array. (Author)

  8. Prostate Dose Escalation by Innovative Inverse Planning-Driven IMRT

    National Research Council Canada - National Science Library

    Xing, Lei

    2005-01-01

    .... Because of the tacit ignorance of intra-structural tradeoff, the IMRT plans generated by these systems for prostate treatment are, at best, sub-optimal and our endeavor of providing the best possible...

  9. GPU-Monte Carlo based fast IMRT plan optimization

    Directory of Open Access Journals (Sweden)

    Yongbao Li

    2014-03-01

    Full Text Available Purpose: Intensity-modulated radiation treatment (IMRT plan optimization needs pre-calculated beamlet dose distribution. Pencil-beam or superposition/convolution type algorithms are typically used because of high computation speed. However, inaccurate beamlet dose distributions, particularly in cases with high levels of inhomogeneity, may mislead optimization, hindering the resulting plan quality. It is desire to use Monte Carlo (MC methods for beamlet dose calculations. Yet, the long computational time from repeated dose calculations for a number of beamlets prevents this application. It is our objective to integrate a GPU-based MC dose engine in lung IMRT optimization using a novel two-steps workflow.Methods: A GPU-based MC code gDPM is used. Each particle is tagged with an index of a beamlet where the source particle is from. Deposit dose are stored separately for beamlets based on the index. Due to limited GPU memory size, a pyramid space is allocated for each beamlet, and dose outside the space is neglected. A two-steps optimization workflow is proposed for fast MC-based optimization. At first step, a rough dose calculation is conducted with only a few number of particle per beamlet. Plan optimization is followed to get an approximated fluence map. In the second step, more accurate beamlet doses are calculated, where sampled number of particles for a beamlet is proportional to the intensity determined previously. A second-round optimization is conducted, yielding the final result.Results: For a lung case with 5317 beamlets, 105 particles per beamlet in the first round, and 108 particles per beam in the second round are enough to get a good plan quality. The total simulation time is 96.4 sec.Conclusion: A fast GPU-based MC dose calculation method along with a novel two-step optimization workflow are developed. The high efficiency allows the use of MC for IMRT optimizations.--------------------------------Cite this article as: Li Y, Tian Z

  10. Use of the 3DVH Software as a complementary method of IMRT pretreatment evaluation; Utilizacao do Software 3DVH como metodo complementar de avaliacao de pre-tratamento de IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Lyra, Jesse G.P.; Bruning, Fabio F.; Funchal, Melissa; Toledo, Hugo V.; Bornatto, Pricila; Fernandes, Tatiane C.O., E-mail: jesse_lyra@hotmail.com [Hospital Erasto Gaertner / Liga Paranaense de Combate ao Cancer (LPCC), Departamento de Radioterapia, Curitiba, PR (Brazil)

    2013-04-15

    The aim of this study is to compare the method of treatment planning evaluation for IMRT using the gamma index to the method of the 3DVH Software. The 3DVH Software was used with the MapCheck2 detector 2D array under a 6MV x-ray beam of linear accelerator equipped with 120 leafs MLC. Nine treatment plans of prostate patients chose randomly and fully anonimatize were performed in the Eclipse planning system, using the AAA calculation algorithm in IMRT sliding window technique. These plans were approved and treated according to the gamma analysis criteria of the institution. The comparisons were made in absolute dose and normalized at maximum dose for each field and then with the 3DVH Software the Dmax, Dmean, D15%, D25%, D35% and D50% parameters for the bladder and rectum, Dmean for the bulb, Dmax for the femur and D95% for the PTV were evaluated. In the planar analysis by field, the plans studied had a minimum of 97.5% approval. The PTV-related differences have relative variation from 1.3 to 2.2%, that is, greater coverage than expected for this structure. For the organs at risk, the relative differences observed were between -5.3 to 25.8%, which could result in a non-approved plan if these variations are close to the clinical tolerances of the OAR. The results show that even a plan compatible with greater than or equal to 95% of the points, the gamma analysis does not give enough information if this plan can or cannot be approved for treatment and that there is a need for more detailed verification of the plan which considers not only the planar evaluation, but also the evaluation of the DVH measured, and the 3DVH Software proved be adequate for this analysis. (author)

  11. Preliminary results of phase I/II study of simultaneous modulated accelerated (SMART) for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Hong; Lee, Sang Wook; Back, Geum Mun [College of Medicine, University of Ulsan, Asan Medical Center, Seoul (Korea, Republic of)] (and others)

    2006-03-15

    To present preliminary results of intensity-modulated radiotherapy (IMRT) using the simultaneous modulated accelerated radiation therapy (SMART) boost technique in patients with nasopharyngeal carcinoma (NPC). Twenty patients who underwent IMRT for non-metastatic NPC at the Asan Medical Center between September 2001 and December 2003 were prospectively evaluated. IMRT was delivered using the 'step and shoot' SMART technique at prescribed doses of 72 Gy (2.4 Gy/day) to the gross tumor volume (GTV), 60 Gy (2 Gy/day) to the clinical target volume (CTV) and metastatic nodal station, and 46 Gy (2 Gy/day) to the clinically negative neck region. Eighteen patients also received concurrent chemotherapy using cisplatin once per week. The median follow-up period was 27 months. Nineteen patients completed the treatment without interruption; the remaining patient interrupted treatment for 2 weeks owing to severe pharyngitis and malnutrition. Five patients (25%) had RTOG grade 3 mucositis, whereas nine (45%) had grade 3 pharyngitis. Seven patients (35%) lost more than 10% of their pretreatment weight, whereas 11 (55%) required intravenous fluids and/or tube feeding. There was no grade 3 or 4 chronic xerostomia. All patients showed complete response. Two patients had distant metastases and loco-regional recurrence, respectively. IMRT using the SMART boost technique allows parotid sparing, as shown clinically and by dosimetry, and may also be more effective biologically. A larger population of patients and a longer follow-up period are needed to evaluate ultimate tumor control and late toxicity.

  12. SU-G-TeP4-02: A Method for Evaluating the Direct Impact of Failed IMRT QAs On Patient Dose

    International Nuclear Information System (INIS)

    Geneser, S; Butkus, M

    2016-01-01

    Purpose: We developed a method to calculate patient doses corresponding to IMRT QA measurements in order to determine and assess the actual dose delivered for plans with failed (or borderline) IMRT QA. This work demonstrates the feasibility of automatically computing delivered patient dose from portal dosimetry measurements in the Varian TPS system, which would provide a valuable and clinically viable IMRT QA tool for physicists and physicians. Methods: IMRT QA fluences were measured using portal dosimetry, processed using in-house matlab software, and imported back into Eclipse to calculate dose on the planning CT. To validate the proposed workflow, the Eclipse calculated portal dose for a 5-field sliding window prostate boost plan was processed as described above. The resulting dose was compared to the planned dose and found to be within 0.5 Gy. Two IMRT QA results for the prostate boost plan (one that failed and one that passed) were processed and the resulting patient doses were evaluated. Results: The max dose difference between IMRT QA #1 and the original planned and approved dose is 4.5 Gy, while the difference between the planned and IMRT QA #2 dose is 4.0 Gy. The inferior portion of the PTV is slightly underdosed in both plans, and the superior portion is slightly overdosed. The patient dose resulting from IMRT QA #1 and #2 differs by only 0.5 Gy. With this new information, it may be argued that the evaluated plan alteration to obtain passing gamma analysis produced clinically irrelevant differences. Conclusion: Evaluation of the delivered QA dose on the planning CT provides valuable information about the clinical relevance of failed or borderline IMRT QAs. This particular workflow demonstrates the feasibility of pushing the measured IMRT QA portal dosimetry results directly back onto the patient planning CT within the Varian system.

  13. SU-G-TeP4-02: A Method for Evaluating the Direct Impact of Failed IMRT QAs On Patient Dose

    Energy Technology Data Exchange (ETDEWEB)

    Geneser, S; Butkus, M [Yale University School of Medicine/YNHH Radiology, New Haven, CT (United States)

    2016-06-15

    Purpose: We developed a method to calculate patient doses corresponding to IMRT QA measurements in order to determine and assess the actual dose delivered for plans with failed (or borderline) IMRT QA. This work demonstrates the feasibility of automatically computing delivered patient dose from portal dosimetry measurements in the Varian TPS system, which would provide a valuable and clinically viable IMRT QA tool for physicists and physicians. Methods: IMRT QA fluences were measured using portal dosimetry, processed using in-house matlab software, and imported back into Eclipse to calculate dose on the planning CT. To validate the proposed workflow, the Eclipse calculated portal dose for a 5-field sliding window prostate boost plan was processed as described above. The resulting dose was compared to the planned dose and found to be within 0.5 Gy. Two IMRT QA results for the prostate boost plan (one that failed and one that passed) were processed and the resulting patient doses were evaluated. Results: The max dose difference between IMRT QA #1 and the original planned and approved dose is 4.5 Gy, while the difference between the planned and IMRT QA #2 dose is 4.0 Gy. The inferior portion of the PTV is slightly underdosed in both plans, and the superior portion is slightly overdosed. The patient dose resulting from IMRT QA #1 and #2 differs by only 0.5 Gy. With this new information, it may be argued that the evaluated plan alteration to obtain passing gamma analysis produced clinically irrelevant differences. Conclusion: Evaluation of the delivered QA dose on the planning CT provides valuable information about the clinical relevance of failed or borderline IMRT QAs. This particular workflow demonstrates the feasibility of pushing the measured IMRT QA portal dosimetry results directly back onto the patient planning CT within the Varian system.

  14. Dosimetric Comparison of Split Field and Fixed Jaw Techniques for Large IMRT Target Volumes in the Head and Neck

    International Nuclear Information System (INIS)

    Srivastava, Shiv P.; Das, Indra J.; Kumar, Arvind; Johnstone, Peter A.S.

    2011-01-01

    Some treatment planning systems (TPSs), when used for large-field (>14 cm) intensity-modulated radiation therapy (IMRT), create split fields that produce excessive multiple-leaf collimator segments, match-line dose inhomogeneity, and higher treatment times than nonsplit fields. A new method using a fixed-jaw technique (FJT) forces the jaw to stay at a fixed position during optimization and is proposed to reduce problems associated with split fields. Dosimetric comparisons between split-field technique (SFT) and FJT used for IMRT treatment is presented. Five patients with head and neck malignancies and regional target volumes were studied and compared with both techniques. Treatment planning was performed on an Eclipse TPS using beam data generated for Varian 2100C linear accelerator. A standard beam arrangement consisting of nine coplanar fields, equally spaced, was used in both techniques. Institutional dose-volume constraints used in head and neck cancer were kept the same for both techniques. The dosimetric coverage for the target volumes between SFT and FJT for head and neck IMRT plan is identical within ±1% up to 90% dose. Similarly, the organs at risk (OARs) have dose-volume coverage nearly identical for all patients. When the total monitor unit (MU) and segments were analyzed, SFT produces statistically significant higher segments (17.3 ± 6.3%) and higher MU (13.7 ± 4.4%) than the FJT. There is no match line in FJT and hence dose uniformity in the target volume is superior to the SFT. Dosimetrically, SFT and FJT are similar for dose-volume coverage; however, the FJT method provides better logistics, lower MU, shorter treatment time, and better dose uniformity. The number of segments and MU also has been correlated with the whole body radiation dose with long-term complications. Thus, FJT should be the preferred option over SFT for large target volumes.

  15. Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linac-conformality versus efficiency of dose delivery

    International Nuclear Information System (INIS)

    Webb, Steve

    2000-01-01

    Intensity-modulated radiotherapy (IMRT) may be delivered with a high-energy-photon linac mounted on a robotic gantry and executing a complex trajectory. In a previous paper an inverse-planning technique was developed for such an application. Here the work is extended to demonstrate the dependence of conformality on the size of the elemental pencil beam, on the complexity of the trajectory and on the sampling of azimuth and elevation of the collimated source. The improved conformality of complex trajectories is demonstrated and benchmarked relative to simpler trajectories, more representative of existing non-robotic IMRT techniques. Specifically, by choosing a very fine pencil beam, exquisitely conformal dose distributions have been obtained. Important sampling considerations have been determined. Expressions have been derived for the dosimetry and monitor-unit efficiency of robotic IMRT. Equivalent trajectories were computed for executing the complex robotic trajectories instead by using a conventional linac. The work benchmarks an ideal in IMRT against which more practical and more common techniques may be measured. (author)

  16. The clinical impact of the couch top and rails on IMRT and arc therapy

    International Nuclear Information System (INIS)

    Pulliam, Kiley B; Howell, Rebecca M; Followill, David; Luo, Dershan; Kry, Stephen F; White, R Allen

    2011-01-01

    The clinical impact of the Varian Exact Couch on dose, volume coverage to targets and critical structures, and tumor control probability (TCP) has not been described. Thus, we examined their effects on IMRT and arc therapy. Five clinical prostate patients were planned with both 6 MV eight-field IMRT and 6 MV two-arc RapidArc techniques using the Eclipse treatment planning system. These plans neglected treatment couch attenuation, as is a common clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the dose-volume histograms from each plan iteration. We used a TCP model to calculate losses in tumor control resulting from not accounting for the couch top and rails. We also verified dose measurements in a phantom. Failure to account for the treatment couch and rails resulted in clinically unacceptable dose and volume coverage losses to the targets for both IMRT and RapidArc. The couch caused average prescription dose losses (relative to plans that ignored the couch) to the prostate of 4.2% and 2.0% for IMRT with the rails out and in, respectively, and 3.2% and 2.9% for RapidArc with the rails out and in, respectively. On average, the percentage of the target covered by the prescribed dose dropped to 35% and 84% for IMRT (rails out and in, respectively) and to 18% and 17% for RapidArc (rails out and in, respectively). The TCP was also reduced by as much as 10.5% (6.3% on average). Dose and volume coverage losses for IMRT plans were primarily due to the rails, while the imaging couch top contributed most to losses for RapidArc. Both the couch top and rails contribute to dose and coverage losses that can render plans clinically unacceptable. A follow-up study we performed found that the less attenuating unipanel mesh couch top available with the Varian Exact couch does not cause a clinically

  17. SU-F-T-295: MLCs Performance and Patient-Specific IMRT QA Using Log File Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Osman, A [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); American University of Biuret Medical Center, Biuret (Lebanon); Maalej, N [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Jayesh, K; Abdel-Rahman, W [King Fahad Specialist Hospital-Dammam, Eastern Province (Saudi Arabia)

    2016-06-15

    Purpose: To analyze the performance of the multi-leaf collimators (MLCs) from the log files recorded during the intensity modulated radiotherapy (IMRT) treatment and to construct the relative fluence maps and do the gamma analysis to compare the planned and executed MLCs movement. Methods: We developed a program to extract and analyze the data from dynamic log files (dynalog files) generated from sliding window IMRT delivery treatments. The program extracts the planned and executed (actual or delivered) MLCs movement, calculates and compares the relative planned and executed fluences. The fluence maps were used to perform the gamma analysis (with 3% dose difference and 3 mm distance to agreement) for 3 IMR patients. We compared our gamma analysis results with those obtained from portal dose image prediction (PDIP) algorithm performed using the EPID. Results: For 3 different IMRT patient treatments, the maximum difference between the planned and the executed MCLs positions was 1.2 mm. The gamma analysis results of the planned and delivered fluences were in good agreement with the gamma analysis from portal dosimetry. The maximum difference for number of pixels passing the gamma criteria (3%/3mm) was 0.19% with respect to portal dosimetry results. Conclusion: MLC log files can be used to verify the performance of the MLCs. Patientspecific IMRT QA based on MLC movement log files gives similar results to EPID dosimetry results. This promising method for patient-specific IMRT QA is fast, does not require dose measurements in a phantom, can be done before the treatment and for every fraction, and significantly reduces the IMRT workload. The author would like to thank King Fahd University of petroleum and Minerals for the support.

  18. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    Science.gov (United States)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Introduction Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. Methods A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. Results The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. Conclusion The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques. PMID:26229623

  19. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    International Nuclear Information System (INIS)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques

  20. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT).

    Science.gov (United States)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-12-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147-53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose-volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  1. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    Energy Technology Data Exchange (ETDEWEB)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham [Andrew Love Cancer Centre, Geelong Hospital, Geelong, Victoria (Australia)

    2013-12-15

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  2. Characteristics of response of oral and pharyngeal mucosa in patients receiving chemo-IMRT for head and neck cancer using hypofractionated accelerated radiotherapy

    International Nuclear Information System (INIS)

    Bhide, Shreerang A.; Gulliford, Sarah; Fowler, Jack; Rosenfelder, Nicola; Newbold, Katie; Harrington, Kevin J.; Nutting, Christopher M.

    2010-01-01

    Purpose: This study describes the acute response of oral and pharyngeal mucosa to chemo-IMRT schedules using different doses per fraction. Materials and methods: Patients, treated in prospective trials of concomitant chemo-IMRT with 2.17 Gy, 2.25 Gy and 2.4 Gy per fraction and identical dose of cisplatin, were included in this study. Acute toxicity was recorded prospectively using the CTCAE v2.0. We describe the incidence and prevalence of grade 3 oral mucositis and dysphagia over time and report the influence of overall treatment time (OTT). The association between the lengths of pharyngeal mucosa receiving 50 Gy (L50) and 60 Gy (L60) and grade 3 dysphagia was tested. Results: The incidence and the peak prevalence of grade 3 dysphagia were significantly higher in patients receiving 2.4 Gy per fraction. The peak prevalence of grade 3 dysphagia was higher and the recovery was slower in patients with lower OTT (median 38 days vs. 42 days) treatment. There was a significant correlation between L50, L60 and grade 3 dysphagia. A L50 and L60 greater than 8 cm resulted in greater than 60% and 70% incidence of grade 3 dysphagia, respectively. Conclusion: The length of pharyngeal mucosa receiving doses close to the prescription dose correlates with grade 3 dysphagia. It was observed that incidence of grade 3 dysphagia was lower and recovery from it was quicker in patients with greater OTT.

  3. Characteristics of response of oral and pharyngeal mucosa in patients receiving chemo-IMRT for head and neck cancer using hypofractionated accelerated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bhide, Shreerang A., E-mail: sabhide@yahoo.co [Royal Marsden Hospital, Sutton, London (United Kingdom); Institute of Cancer Research, Sutton, London (United Kingdom); Gulliford, Sarah [Institute of Cancer Research, Sutton, London (United Kingdom); Fowler, Jack [Department of Human Oncology, University of Wisconsin, Madison (United States); Department of Medical Physics, University of Wisconsin, Madison (United States); Rosenfelder, Nicola; Newbold, Katie [Royal Marsden Hospital, Sutton, London (United Kingdom); Harrington, Kevin J; Nutting, Christopher M [Royal Marsden Hospital, Sutton, London (United Kingdom); Institute of Cancer Research, Sutton, London (United Kingdom)

    2010-10-15

    Purpose: This study describes the acute response of oral and pharyngeal mucosa to chemo-IMRT schedules using different doses per fraction. Materials and methods: Patients, treated in prospective trials of concomitant chemo-IMRT with 2.17 Gy, 2.25 Gy and 2.4 Gy per fraction and identical dose of cisplatin, were included in this study. Acute toxicity was recorded prospectively using the CTCAE v2.0. We describe the incidence and prevalence of grade 3 oral mucositis and dysphagia over time and report the influence of overall treatment time (OTT). The association between the lengths of pharyngeal mucosa receiving 50 Gy (L50) and 60 Gy (L60) and grade 3 dysphagia was tested. Results: The incidence and the peak prevalence of grade 3 dysphagia were significantly higher in patients receiving 2.4 Gy per fraction. The peak prevalence of grade 3 dysphagia was higher and the recovery was slower in patients with lower OTT (median 38 days vs. 42 days) treatment. There was a significant correlation between L50, L60 and grade 3 dysphagia. A L50 and L60 greater than 8 cm resulted in greater than 60% and 70% incidence of grade 3 dysphagia, respectively. Conclusion: The length of pharyngeal mucosa receiving doses close to the prescription dose correlates with grade 3 dysphagia. It was observed that incidence of grade 3 dysphagia was lower and recovery from it was quicker in patients with greater OTT.

  4. Hematologic Toxicity in RTOG 0418: A Phase 2 Study of Postoperative IMRT for Gynecologic Cancer

    International Nuclear Information System (INIS)

    Klopp, Ann H.; Moughan, Jennifer; Portelance, Lorraine; Miller, Brigitte E.; Salehpour, Mohammad R.; Hildebrandt, Evangeline; Nuanjing, Jenny; D'Souza, David; Souhami, Luis; Small, William; Gaur, Rakesh; Jhingran, Anuja

    2013-01-01

    Purpose: Intensity modulated radiation therapy (IMRT), compared with conventional 4-field treatment, can reduce the volume of bone marrow irradiated. Pelvic bone marrow sparing has produced a clinically significant reduction in hematologic toxicity (HT). This analysis investigated HT in Radiation Therapy Oncology Group (RTOG) 0418, a prospective study to test the feasibility of delivering postoperative IMRT for cervical and endometrial cancer in a multiinstitutional setting. Methods and Materials: Patients in the RTOG 0418 study were treated with postoperative IMRT to 50.4 Gy to the pelvic lymphatics and vagina. Endometrial cancer patients received IMRT alone, whereas patients with cervical cancer received IMRT and weekly cisplatin (40 mg/m 2 ). Pelvic bone marrow was defined within the treatment field by using a computed tomography density-based autocontouring algorithm. The volume of bone marrow receiving 10, 20, 30, and 40 Gy and the median dose to bone marrow were correlated with HT, graded by Common Terminology Criteria for Adverse Events, version 3.0, criteria. Results: Eighty-three patients were eligible for analysis (43 with endometrial cancer and 40 with cervical cancer). Patients with cervical cancer treated with weekly cisplatin and pelvic IMRT had grades 1-5 HT (23%, 33%, 25%, 0%, and 0% of patients, respectively). Among patients with cervical cancer, 83% received 5 or more cycles of cisplatin, and 90% received at least 4 cycles of cisplatin. The median percentage volume of bone marrow receiving 10, 20, 30, and 40 Gy in all 83 patients, respectively, was 96%, 84%, 61%, and 37%. Among cervical cancer patients with a V40 >37%, 75% had grade 2 or higher HT compared with 40% of patients with a V40 less than or equal to 37% (P =.025). Cervical cancer patients with a median bone marrow dose of >34.2 Gy also had higher rates of grade ≥2 HT than did those with a dose of ≤34.2 Gy (74% vs 43%, P=.049). Conclusions: Pelvic IMRT with weekly cisplatin is

  5. Hematologic Toxicity in RTOG 0418: A Phase 2 Study of Postoperative IMRT for Gynecologic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Klopp, Ann H., E-mail: aklopp@mdanderson.org [The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Moughan, Jennifer [RTOG Statistical Center, Philadelphia, Pennsylvania (United States); Portelance, Lorraine [Sylvester Comprehensive Cancer Center, Miami, Florida (United States); Miller, Brigitte E. [Wake Forest University Baptist Medical Center, Winston-Salem, North Carolina (United States); Salehpour, Mohammad R.; Hildebrandt, Evangeline; Nuanjing, Jenny [The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); D' Souza, David [London Regional Cancer Center, University of Western Ontario, London, Ontario (Canada); Souhami, Luis [Sylvester Comprehensive Cancer Center, Miami, Florida (United States); Small, William [Northwestern Memorial Hospital, Chicago, Illinois (United States); Gaur, Rakesh [St. Luke' s Cancer Institute, Kansas City, Missouri (United States); Jhingran, Anuja [The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2013-05-01

    Purpose: Intensity modulated radiation therapy (IMRT), compared with conventional 4-field treatment, can reduce the volume of bone marrow irradiated. Pelvic bone marrow sparing has produced a clinically significant reduction in hematologic toxicity (HT). This analysis investigated HT in Radiation Therapy Oncology Group (RTOG) 0418, a prospective study to test the feasibility of delivering postoperative IMRT for cervical and endometrial cancer in a multiinstitutional setting. Methods and Materials: Patients in the RTOG 0418 study were treated with postoperative IMRT to 50.4 Gy to the pelvic lymphatics and vagina. Endometrial cancer patients received IMRT alone, whereas patients with cervical cancer received IMRT and weekly cisplatin (40 mg/m{sup 2}). Pelvic bone marrow was defined within the treatment field by using a computed tomography density-based autocontouring algorithm. The volume of bone marrow receiving 10, 20, 30, and 40 Gy and the median dose to bone marrow were correlated with HT, graded by Common Terminology Criteria for Adverse Events, version 3.0, criteria. Results: Eighty-three patients were eligible for analysis (43 with endometrial cancer and 40 with cervical cancer). Patients with cervical cancer treated with weekly cisplatin and pelvic IMRT had grades 1-5 HT (23%, 33%, 25%, 0%, and 0% of patients, respectively). Among patients with cervical cancer, 83% received 5 or more cycles of cisplatin, and 90% received at least 4 cycles of cisplatin. The median percentage volume of bone marrow receiving 10, 20, 30, and 40 Gy in all 83 patients, respectively, was 96%, 84%, 61%, and 37%. Among cervical cancer patients with a V40 >37%, 75% had grade 2 or higher HT compared with 40% of patients with a V40 less than or equal to 37% (P =.025). Cervical cancer patients with a median bone marrow dose of >34.2 Gy also had higher rates of grade ≥2 HT than did those with a dose of ≤34.2 Gy (74% vs 43%, P=.049). Conclusions: Pelvic IMRT with weekly cisplatin is

  6. Fifteen-year results of a randomized prospective trial of hyperfractionated chest wall irradiation versus once-daily chest wall irradiation after chemotherapy and mastectomy for patients with locally advanced noninflammatory breast cancer

    International Nuclear Information System (INIS)

    Buchholz, Thomas A.; Strom, Eric A.; Oswald, Mary Jane; Perkins, George H.; Oh, Julia; Domain, Delora; Yu, Tse-Kuan; Woodward, Wendy A.; Tereffe, Welela; Singletary, S. Eva; Thomas, Eva; Buzdar, Aman U.; Hortobagyi, Gabriel N.; McNeese, Marsha D.

    2006-01-01

    Purpose: To analyze the results of a Phase III clinical trial that investigated whether a hyperfractionated radiotherapy (RT) schedule could reduce the risk of locoregional recurrence in patients with locally advanced breast cancer treated with chemotherapy and mastectomy. Methods and Materials: Between 1985 and 1989, 200 patients with clinical Stage III noninflammatory breast cancer were enrolled in a prospective study investigating neoadjuvant and adjuvant chemotherapy. Of the 179 patients treated with mastectomy after neoadjuvant chemotherapy, 108 participated in a randomized component of the trial that compared a dose-escalated, hyperfractionated (twice-daily, b.i.d.) chest wall RT schedule (72 Gy in 1.2-Gy b.i.d. fractions) with a once-daily (q.d.) schedule (60 Gy in 2-Gy q.d. fractions). In both arms of the study, the supraclavicular fossa and axillary apex were treated once daily to 50 Gy. The median follow-up period was 15 years. Results: The 15-year actuarial locoregional recurrence rate was 7% for the q.d. arm and 12% for the b.i.d. arm (p = 0.36). The rates of severe acute toxicity were similar (4% for q.d. vs. 5% for b.i.d.), but moist desquamation developed in 42% of patients in the b.i.d. arm compared with 28% of the patients in the q.d. arm (p = 0.16). The 15-year actuarial rate of severe late RT complications did not differ between the two arms (6% for q.d. vs. 11% for b.i.d., p = 0.54). Conclusion: Although the sample size of this study was small, we found no evidence that this hyperfractionation schedule of postmastectomy RT offered a clinical advantage. Therefore, we have concluded that it should not be further studied in this cohort of patients

  7. Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom

    International Nuclear Information System (INIS)

    Han Tao; Mourtada, Firas; Kisling, Kelly; Mikell, Justin; Followill, David; Howell, Rebecca

    2012-01-01

    Purpose: The purpose of this study was to verify the dosimetric performance of Acuros XB (AXB), a grid-based Boltzmann solver, in intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Methods: The Radiological Physics Center (RPC) head and neck (H and N) phantom was used for all calculations and measurements in this study. Clinically equivalent IMRT and VMAT plans were created on the RPC H and N phantom in the Eclipse treatment planning system (version 10.0) by using RPC dose prescription specifications. The dose distributions were calculated with two different algorithms, AXB 11.0.03 and anisotropic analytical algorithm (AAA) 10.0.24. Two dose report modes of AXB were recorded: dose-to-medium in medium (D m,m ) and dose-to-water in medium (D w,m ). Each treatment plan was delivered to the RPC phantom three times for reproducibility by using a Varian Clinac iX linear accelerator. Absolute point dose and planar dose were measured with thermoluminescent dosimeters (TLDs) and GafChromic registered EBT2 film, respectively. Profile comparison and 2D gamma analysis were used to quantify the agreement between the film measurements and the calculated dose distributions from both AXB and AAA. The computation times for AAA and AXB were also evaluated. Results: Good agreement was observed between measured doses and those calculated with AAA or AXB. Both AAA and AXB calculated doses within 5% of TLD measurements in both the IMRT and VMAT plans. Results of AXB Dm,m (0.1% to 3.6%) were slightly better than AAA (0.2% to 4.6%) or AXB Dw,m (0.3% to 5.1%). The gamma analysis for both AAA and AXB met the RPC 7%/4 mm criteria (over 90% passed), whereas AXB Dm,m met 5%/3 mm criteria in most cases. AAA was 2 to 3 times faster than AXB for IMRT, whereas AXB was 4-6 times faster than AAA for VMAT. Conclusions: AXB was found to be satisfactorily accurate when compared to measurements in the RPC H and N phantom. Compared with AAA, AXB results were equal

  8. Domestic comparison of radiation treatment techniques for breast cancer: 3D-CRT, IMRT and VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bo Ram; Yoon, Myong Geun [Dept. of Bio-convergence Engineering, College of Health Science, Korea University, Seoul (Korea, Republic of); Lee, Sun Young [Dept. of Radiation Oncology, Yusung Sun Medical Center, Daejeon (Korea, Republic of)

    2013-09-15

    The purpose of this study is to compare method in the treatment of breast cancer using dose index. And, it is to find the optimized treatment technique to the patient. The phantom filled with tissue-equivalent material were used simulation and treatment as techniques of 3D-CRT, IMRT, VMAT was planned using Eclipse v10. By using HI(homogeneity index), CI(Conformity index), OE (Organ equivalent dose), EAR(Excess Absolute Risk), were assessed for each treatment plans. HI and CI of 3D-CRT, IMRT, VMAT were calculated 16.89, 11.21, 9.55 and 0.59, 0.61, 0.83. The organ average doses of Lt lung, Rt lung, liver, heart, esophagus, cord, Lt breast, trachea and stomach were 0.01 ∼ 2.02 Gy, 0.36 ∼ 5.01 Gy, 0.25 ∼ 2.49 Gy, 0.14 ∼ 6.92 Gy, 0.03 ∼ 2.02 Gy, 0.01 ∼ 1.06 Gy, 0.25 ∼ 6.08 Gy, 0.08 ∼ 0.59 Gy, 0.01 ∼ 1.34 Gy, respectively. The OED, EAR of the IMRT and VMAT show higher than 3D-CRT. As the result of this study, we could confirm being higher dose index(HI, CI) in IMRT and VMAT than 3D-CRT, but doses of around normal organs was higher IMRT, VMAT than 3D-CRT.

  9. Acute toxicity of postoperative IMRT and chemotherapy for endometrial cancer

    International Nuclear Information System (INIS)

    Tierney, R.M.; Powell, M.A.; Mutch, D.G.; Gibb, R.K.; Rader, J.S.; Grigsby, P.W.

    2007-01-01

    The aim of this study was to determine the acute toxicity of postoperative intensity-modulated radiotherapy (IMRT) with and without chemotherapy in patients with endometrial cancer. A total of 19 patients with stages IB-IVB endometrial cancer who underwent surgery and postoperative IMRT were reviewed. The treatment planning goal was to cover the tissue at risk and minimize the dose to the bladder, bowel, and bone marrow. Median dose was 50.4 Gy (range 49.6-51.2 Gy). Altogether, 14 patients underwent chemotherapy; most were given carboplatin and paclitaxel. Toxicity was scored according to the Common Terminology Criteria for Adverse Events version 3.0 (CTCAE). The prescribed radiation treatment was completed in all patients. The prescribed cycles of chemotherapy were completed in all 14 patients, except one who received five of six cycles limited by prolonged thrombocytopenia. Chemotherapy was delayed in two patients (14%). Three patients required growth factor support during chemotherapy, and one patient required a blood transfusion. Acute grades 3-4 hematological toxicity occurred in 9 of the 14 patients (64%) who underwent chemotherapy. None experienced acute grade 3 or 4 genitourinary or gastrointestinal toxicity. Adjuvant IMRT and chemotherapy following surgery in patients with endometrial cancer is well tolerated and did not lead to treatment modification in most patients. (author)

  10. Intensity modulated radiation therapy (IMRT: differences in target volumes and improvement in clinically relevant doses to small bowel in rectal carcinoma

    Directory of Open Access Journals (Sweden)

    Delclos Marc E

    2011-06-01

    Full Text Available Abstract Background A strong dose-volume relationship exists between the amount of small bowel receiving low- to intermediate-doses of radiation and the rates of acute, severe gastrointestinal toxicity, principally diarrhea. There is considerable interest in the application of highly conformal treatment approaches, such as intensity-modulated radiation therapy (IMRT, to reduce dose to adjacent organs-at-risk in the treatment of carcinoma of the rectum. Therefore, we performed a comprehensive dosimetric evaluation of IMRT compared to 3-dimensional conformal radiation therapy (3DCRT in standard, preoperative treatment for rectal cancer. Methods Using RTOG consensus anorectal contouring guidelines, treatment volumes were generated for ten patients treated preoperatively at our institution for rectal carcinoma, with IMRT plans compared to plans derived from classic anatomic landmarks, as well as 3DCRT plans treating the RTOG consensus volume. The patients were all T3, were node-negative (N = 1 or node-positive (N = 9, and were planned to a total dose of 45-Gy. Pairwise comparisons were made between IMRT and 3DCRT plans with respect to dose-volume histogram parameters. Results IMRT plans had superior PTV coverage, dose homogeneity, and conformality in treatment of the gross disease and at-risk nodal volume, in comparison to 3DCRT. Additionally, in comparison to the 3DCRT plans, IMRT achieved a concomitant reduction in doses to the bowel (small bowel mean dose: 18.6-Gy IMRT versus 25.2-Gy 3DCRT; p = 0.005, bladder (V40Gy: 56.8% IMRT versus 75.4% 3DCRT; p = 0.005, pelvic bones (V40Gy: 47.0% IMRT versus 56.9% 3DCRT; p = 0.005, and femoral heads (V40Gy: 3.4% IMRT versus 9.1% 3DCRT; p = 0.005, with an improvement in absolute volumes of small bowel receiving dose levels known to induce clinically-relevant acute toxicity (small bowel V15Gy: 138-cc IMRT versus 157-cc 3DCRT; p = 0.005. We found that the IMRT treatment volumes were typically larger than that

  11. Long-term disease control and toxicity outcomes following surgery and intensity modulated radiation therapy (IMRT) in pediatric craniopharyngioma.

    Science.gov (United States)

    Greenfield, Brad J; Okcu, Mehmet F; Baxter, Patricia A; Chintagumpala, Murali; Teh, Bin S; Dauser, Robert C; Su, Jack; Desai, Snehal S; Paulino, Arnold C

    2015-02-01

    To report long-term progression-free survival (PFS) and late-toxicity outcomes in pediatric craniopharyngioma patients treated with IMRT. Twenty-four children were treated with IMRT to a median dose of 50.4Gy (range, 49.8-54Gy). The clinical target volume (CTV) was the gross tumor volume (GTV) with a 1cm margin. The planning target volume (PTV) was the CTV with a 3-5mm margin. Median follow-up was 107.3months. The 5- and 10-year PFS rates were 65.8% and 60.7%. The 5- and 10-year cystic PFS rates were 70.2% and 65.2% while the 5- and 10-year solid PFS were the same at 90.7%. Endocrinopathy was seen in 42% at initial diagnosis and in 74% after surgical intervention, prior to IMRT. Hypothalamic dysfunction and visual deficits were associated with increasing PTV and number of surgical interventions. IMRT is a viable treatment option for pediatric craniopharyngioma. Despite the use of IMRT, majority of the craniopharyngioma patients experienced long-term toxicity, many of which present prior to radiotherapy. Limitations of retrospective analyses on small patient cohort elicit the need for a prospective multi-institutional study to determine the absolute benefit of IMRT in pediatric craniopharyngioma. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. Long-term disease control and toxicity outcomes following surgery and intensity modulated radiation therapy (IMRT) in pediatric craniopharyngioma

    International Nuclear Information System (INIS)

    Greenfield, Brad J.; Okcu, Mehmet F.; Baxter, Patricia A.; Chintagumpala, Murali; Teh, Bin S.; Dauser, Robert C.; Su, Jack; Desai, Snehal S.; Paulino, Arnold C.

    2015-01-01

    Purpose: To report long-term progression-free survival (PFS) and late-toxicity outcomes in pediatric craniopharyngioma patients treated with IMRT. Patients and methods: Twenty-four children were treated with IMRT to a median dose of 50.4 Gy (range, 49.8–54 Gy). The clinical target volume (CTV) was the gross tumor volume (GTV) with a 1 cm margin. The planning target volume (PTV) was the CTV with a 3–5 mm margin. Median follow-up was 107.3 months. Results: The 5- and 10-year PFS rates were 65.8% and 60.7%. The 5- and 10-year cystic PFS rates were 70.2% and 65.2% while the 5- and 10-year solid PFS were the same at 90.7%. Endocrinopathy was seen in 42% at initial diagnosis and in 74% after surgical intervention, prior to IMRT. Hypothalamic dysfunction and visual deficits were associated with increasing PTV and number of surgical interventions. Conclusions: IMRT is a viable treatment option for pediatric craniopharyngioma. Despite the use of IMRT, majority of the craniopharyngioma patients experienced long-term toxicity, many of which present prior to radiotherapy. Limitations of retrospective analyses on small patient cohort elicit the need for a prospective multi-institutional study to determine the absolute benefit of IMRT in pediatric craniopharyngioma

  13. An Approach for Practical Multiobjective IMRT Treatment Planning

    International Nuclear Information System (INIS)

    Craft, David; Halabi, Tarek; Shih, Helen A.; Bortfeld, Thomas

    2007-01-01

    Purpose: To introduce and demonstrate a practical multiobjective treatment planning procedure for intensity-modulated radiation therapy (IMRT) planning. Methods and Materials: The creation of a database of Pareto optimal treatment plans proceeds in two steps. The first step solves an optimization problem that finds a single treatment plan which is close to a set of clinical aspirations. This plan provides an example of what is feasible, and is then used to determine mutually satisfiable hard constraints for the subsequent generation of the plan database. All optimizations are done using linear programming. Results: The two-step procedure is applied to a brain, a prostate, and a lung case. The plan databases created allow for the selection of a final treatment plan based on the observed tradeoffs between the various organs involved. Conclusions: The proposed method reduces the human iteration time common in IMRT treatment planning. Additionally, the database of plans, when properly viewed, allows the decision maker to make an informed final plan selection

  14. Continuous Arc Rotation of the Couch Therapy for the Delivery of Accelerated Partial Breast Irradiation: A Treatment Planning Analysis

    International Nuclear Information System (INIS)

    Shaitelman, Simona F.; Kim, Leonard H.; Yan Di; Martinez, Alvaro A.; Vicini, Frank A.; Grills, Inga S.

    2011-01-01

    Purpose: We present a novel form of arc therapy: continuous arc rotation of the couch (C-ARC) and compare its dosimetry with three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) for accelerated partial breast irradiation (APBI). C-ARC, like VMAT, uses a modulated beam aperture and dose rate, but with the couch, not the gantry, rotating. Methods and Materials: Twelve patients previously treated with APBI using 3D-CRT were replanned with (1) C-ARC, (2) IMRT, and (3) VMAT. C-ARC plans were designed with one medial and one lateral arc through which the couch rotated while the gantry was held stationary at a tangent angle. Target dose coverage was normalized to the 3D-CRT plan. Comparative endpoints were dose to normal breast tissue, lungs, and heart and monitor units prescribed. Results: Compared with 3D-CRT, C-ARC, IMRT, and VMAT all significantly reduced the ipsilateral breast V50% by the same amount (mean, 7.8%). Only C-ARC and IMRT plans significantly reduced the contralateral breast maximum dose, the ipsilateral lung V5Gy, and the heart V5%. C-ARC used on average 40%, 30%, and 10% fewer monitor units compared with 3D-CRT, IMRT, and VMAT, respectively. Conclusions: C-ARC provides improved dosimetry and treatment efficiency, which should reduce the risks of toxicity and secondary malignancy. Its tangent geometry avoids irradiation of critical structures that is unavoidable using the en face geometry of VMAT.

  15. Hippocampal-Sparing Whole-Brain Radiotherapy: A 'How-To' Technique Using Helical Tomotherapy and Linear Accelerator-Based Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Gondi, Vinai; Tolakanahalli, Ranjini; Mehta, Minesh P.; Tewatia, Dinesh; Rowley, Howard; Kuo, John S.; Khuntia, Deepak; Tome, Wolfgang A.

    2010-01-01

    Purpose: Sparing the hippocampus during cranial irradiation poses important technical challenges with respect to contouring and treatment planning. Herein we report our preliminary experience with whole-brain radiotherapy using hippocampal sparing for patients with brain metastases. Methods and Materials: Five anonymous patients previously treated with whole-brain radiotherapy with hippocampal sparing were reviewed. The hippocampus was contoured, and hippocampal avoidance regions were created using a 5-mm volumetric expansion around the hippocampus. Helical tomotherapy and linear accelerator (LINAC)-based intensity-modulated radiotherapy (IMRT) treatment plans were generated for a prescription dose of 30 Gy in 10 fractions. Results: On average, the hippocampal avoidance volume was 3.3 cm 3 , occupying 2.1% of the whole-brain planned target volume. Helical tomotherapy spared the hippocampus, with a median dose of 5.5 Gy and maximum dose of 12.8 Gy. LINAC-based IMRT spared the hippocampus, with a median dose of 7.8 Gy and maximum dose of 15.3 Gy. On a per-fraction basis, mean dose to the hippocampus (normalized to 2-Gy fractions) was reduced by 87% to 0.49 Gy 2 using helical tomotherapy and by 81% to 0.73 Gy 2 using LINAC-based IMRT. Target coverage and homogeneity was acceptable with both IMRT modalities, with differences largely attributed to more rapid dose fall-off with helical tomotherapy. Conclusion: Modern IMRT techniques allow for sparing of the hippocampus with acceptable target coverage and homogeneity. Based on compelling preclinical evidence, a Phase II cooperative group trial has been developed to test the postulated neurocognitive benefit.

  16. Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

    International Nuclear Information System (INIS)

    Ostheimer, Christian; Huebsch, Patrick; Janich, Martin; Gerlach, Reinhard; Vordermark, Dirk

    2016-01-01

    Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8% –88.4% in coplanar, 77.5%–88.2% in non-coplanar IMRT and 82.8%–90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue

  17. Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

    Energy Technology Data Exchange (ETDEWEB)

    Ostheimer, Christian; Huebsch, Patrick; Janich, Martin; Gerlach, Reinhard; Vordermark, Dirk [Dept. of Radiation Oncology, Faculty of Medicine, Martin Luther University Halle-Wittenberg, Halle (Germany)

    2016-12-15

    Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8% –88.4% in coplanar, 77.5%–88.2% in non-coplanar IMRT and 82.8%–90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

  18. A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer

    International Nuclear Information System (INIS)

    Chitapanarux, Imjai; Tharavichitkul, Ekkasit; Nobnop, Wannapa; Wanwilairat, Somsak; Vongtama, Roy; Traisathit, Patrinee

    2015-01-01

    The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy TM (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our center between January 2011 and January 2014. SaS-IMRT and HT treatment plans were generated for each patient. The dosimetric values for target coverage and organ-at-risk (OAR) sparing were compared according to the criteria of the International Commission on Radiation Units and Measurements 83 (ICRU 83) guidelines. Differences in beam-on time (BOT) were also compared. All the PTV dosimetric parameters (D5%, D50% and D95%) for the HT plan were (statistically significantly) of better quality than those for the SaS-IMRT plan (P-value < 0.001 in all respects). HT was also significantly more accurate than SaS-IMRT with respect to the D98% and Dmean of the CTV (P-values of 0.008 and <0.001, respectively). The median Conformity Index (CI) did not differ between the two plans (P-value = 0.057). However, the Uniformity Index for HT was significantly better than that for SaS-IMRT (P-value < 0.001). The median of D50% for the bladder, rectum and small bowel were significantly lower in HT planning than SaS-IMRT (P-value < 0.001). For D2%, we found that HT provided better sparing to the rectum and bladder (P-value < 0.001). However, the median of D2% for the small bowel was comparable for both plans. The median of Dmax of the head of the left femur was significantly lower in the HT plan, but this did not apply for the head of the right femur. BOT for HT was significantly shorter than for SaS-IMRT (P-value < 0.001). HT provided highly accurate plans, with more homogeneous PTV coverage and superior sparing of OARs than SaS-IMRT. In addition, HT enabled a shorter delivery time than SaS-IMRT. (author)

  19. Whole brain radiotherapy with adjuvant or concomitant boost in brain metastasis: dosimetric comparison between helical and volumetric IMRT technique.

    Science.gov (United States)

    Borghetti, Paolo; Pedretti, Sara; Spiazzi, Luigi; Avitabile, Rossella; Urpis, Mauro; Foscarini, Federica; Tesini, Giulia; Trevisan, Francesca; Ghirardelli, Paolo; Pandini, Sara Angela; Triggiani, Luca; Magrini, Stefano Maria; Buglione, Michela

    2016-04-19

    To compare and evaluate the possible advantages related to the use of VMAT and helical IMRT and two different modalities of boost delivering, adjuvant stereotactic boost (SRS) or simultaneous integrated boost (SIB), in the treatment of brain metastasis (BM) in RPA classes I-II patients. Ten patients were treated with helical IMRT, 5 of them with SRS after whole brain radiotherapy (WBRT) and 5 with SIB. MRI co-registration with planning CT was mandatory and prescribed doses were 30 Gy in 10 fractions (fr) for WBRT and 15Gy/1fr or 45Gy/10fr in SRS or SIB, respectively. For each patient, 4 "treatment plans" (VMAT SRS and SIB, helical IMRT SRS and SIB) were calculated and accepted if PTV boost was included in 95 % isodose and dose constraints of the main organs at risk were respected without major deviations. Homogeneity Index (HI), Conformal Index (CI) and Conformal Number (CN) were considered to compare the different plans. Moreover, time of treatment delivery was calculated and considered in the analysis. Volume of brain metastasis ranged between 1.43 and 51.01 cc (mean 12.89 ± 6.37 ml) and 3 patients had double lesions. V95% resulted over 95 % in the average for each kind of technique, but the "target coverage" was inadequate for VMAT planning with two sites. The HI resulted close to the ideal value of zero in all cases; VMAT-SIB, VMAT-SRS, Helical IMRT-SIB and Helical IMRT-SRS showed mean CI of 2.15, 2.10, 2.44 and 1.66, respectively (optimal range: 1.5-2.0). Helical IMRT-SRS was related to the best and reliable finding of CN (0.66). The mean of treatment time was 210 s, 467 s, 440 s, 1598 s, respectively, for VMAT-SIB, VMAT-SRS, Helical IMRT-SIB and Helical IMRT-SRS. This dosimetric comparison show that helical IMRT obtain better target coverage and respect of CI and CN; VMAT could be acceptable in solitary metastasis. SIB modality can be considered as a good choice for clinical and logistic compliance; literature's preliminary data are confirming also a

  20. Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation

    International Nuclear Information System (INIS)

    Bortfeld, Thomas; Jokivarsi, Kimmo; Goitein, Michael; Kung, Jong; Jiang, Steve B.

    2002-01-01

    There has been some concern that organ motion, especially intra-fraction organ motion due to breathing, can negate the potential merit of intensity-modulated radiotherapy (IMRT). We wanted to find out whether this concern is justified. Specifically, we wanted to investigate whether IMRT delivery techniques with moving parts, e.g., with a multileaf collimator (MLC), are particularly sensitive to organ motion due to the interplay between organ motion and leaf motion. We also wanted to know if, and by how much, fractionation of the treatment can reduce the effects. We performed a statistical analysis and calculated the expected dose values and dose variances for volume elements of organs that move during the delivery of the IMRT. We looked at the overall influence of organ motion during the course of a fractionated treatment. A linear-quadratic model was used to consider fractionation effects. Furthermore, we developed software to simulate motion effects for IMRT delivery with an MLC, with compensators, and with a scanning beam. For the simulation we assumed a sinusoidal motion in an isocentric plane. We found that the expected dose value is independent of the treatment technique. It is just a weighted average over the path of motion of the dose distribution without motion. If the treatment is delivered in several fractions, the distribution of the dose around the expected value is close to a Gaussian. For a typical treatment with 30 fractions, the standard deviation is generally within 1% of the expected value for MLC delivery if one assumes a typical motion amplitude of 5 mm (1 cm peak to peak). The standard deviation is generally even smaller for the compensator but bigger for scanning beam delivery. For the latter it can be reduced through multiple deliveries ('paintings') of the same field. In conclusion, the main effect of organ motion in IMRT is an averaging of the dose distribution without motion over the path of the motion. This is the same as for treatments

  1. A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware.

    Science.gov (United States)

    Rosca, Florin

    2012-06-01

    To present a mixed electron and photon IMRT planning technique using electron beams with an energy range of 6-22 MeV and standard hardware that minimizes integral dose to patients for targets as deep as 7.5 cm. Ten brain cases, two lung, a thyroid, an abdominal, and a parotid case were planned using two planning techniques: a photon-only IMRT (IMRT) versus a mixed modality treatment (E+IMRT) that includes an enface electron beam and a photon IMRT portion that ensures a uniform target coverage. The electron beam is delivered using a regular cutout placed in an electron cone. The electron energy was chosen to provide a good trade-off between minimizing integral dose and generating a uniform, deliverable plan. The authors choose electron energies that cover the deepest part of PTV with the 65%-70% isodose line. The normal tissue integral dose, the dose for ring structures around the PTV, and the volumes of the 75%, 50%, and 25% isosurfaces were used to compare the dose distributions generated by the two planning techniques. The normal tissue integral dose was lowered by about 20% by the E+IMRT plans compared to the photon-only IMRT ones for most studied cases. With the exception of lungs, the dose reduction associated to the E+IMRT plans was more pronounced further away from the target. The average dose ratio delivered to the 0-2 cm and the 2-4 cm ring structures for brain patients for the two planning techniques were 89.6% and 70.8%, respectively. The enhanced dose sparing away from the target for the brain patients can also be observed in the ratio of the 75%, 50%, and 25% isodose line volumes for the two techniques, which decreases from 85.5% to 72.6% and further to 65.1%, respectively. For lungs, the lateral electron beams used in the E+IMRT plans were perpendicular to the mostly anterior/posterior photon beams, generating much more conformal plans. The authors proved that even using the existing electron delivery hardware, a mixed electron/photon planning

  2. IMRT and radiation protection in the prostate cancer therapy

    International Nuclear Information System (INIS)

    Santos, Helena C.; Silva, Andre R.M.; Oliveira, Claudia F.M.

    2015-01-01

    This study aims to specify the technological advances that IMRT presents relative to other traditional radiotherapy, particularly to conformal radiotherapy three dimensional (3D-TCR) and benefits compared to the side effects caused by from treatment of radiotherapy

  3. Importance of the initial volume of parotid glands in xerostomia for patients with head and neck cancers treated with IMRT

    International Nuclear Information System (INIS)

    Nishimura, Yasumasa; Nakamatsu, Kiyoshi; Shibata, Toru; Kanamori, Shuichi; Koike, Ryuta; Okumura, Masahiko; Suzuki, Minoru

    2005-01-01

    Our aim was to evaluate predictors of xerostomia in patients with head and neck cancers treated with intensity-modulated radiation therapy (IMRT). Thirty-three patients with pharyngeal cancer were evaluated for xerostomia after having been treated with IMRT. All patients were treated with whole-neck irradiation of 46-50 Gy by IMRT, followed by boost IMRT to the high-risk clinical target volume to a total dose of 56-70 Gy in 28-35 fractions (median, 68 Gy). For boost IMRT, a second computed tomography (CT-2) scan was done in the third to fourth week of IMRT. Xerostomia was scored 3-4 months after the start of IMRT. The mean doses to the contralateral and ipsilateral parotid glands were 24.0±6.2 and 30.3±6.6 Gy, respectively. Among the 33 patients, xerostomia of grades 0, 1, 2 and 3 was noted in one, 18, 12 and two patients, respectively. Although the mean dose to the parotid glands was not correlated with the grade of xerostomia, the initial volume of the parotid glands was correlated with the grade of xerostomia (P=0.04). Of 17 patients with small parotid glands (≤38.8 ml) on initial CT (CT-1), 11 (65%) showed grade 2 or grade 3 xerostomia, whereas only three (19%) of 16 patients with larger parotid glands showed grade 2 xerostomia (P<0.05). The mean volume of the parotid glands on CT-1 was 43.1±15.2 ml, but decreased significantly to 32.0±11.4 ml (74%) on CT-2 (P<0.0001). Initial volumes of the parotid glands are significantly correlated with the grade of xerostomia in patients treated with IMRT. The volume of the parotid glands decreased significantly during the course of IMRT. (author)

  4. Investigation of effective decision criteria for multiobjective optimization in IMRT.

    Science.gov (United States)

    Holdsworth, Clay; Stewart, Robert D; Kim, Minsun; Liao, Jay; Phillips, Mark H

    2011-06-01

    To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two interacting algorithms: (i) a deterministic inverse planning optimization of beamlet intensities that minimizes a weighted sum of quadratic penalty objectives to generate IMRT plans and (ii) an evolutionary algorithm that selects the superior IMRT plans using decision criteria and uses those plans to determine the new weights and penalty objectives of each new plan. Plans resulting from the deterministic algorithm were evaluated by the evolutionary algorithm using a set of decision criteria for both targets and organs at risk (OARs). Decision criteria used included variation in the target dose distribution, mean dose, maximum dose, generalized equivalent uniform dose (gEUD), an equivalent uniform dose (EUD(alpha,beta) formula derived from the linear-quadratic survival model, and points on dose volume histograms (DVHs). In order to quantatively compare results from trials using different decision criteria, a neutral set of comparison metrics was used. For each set of decision criteria investigated, IMRT plans were calculated for four different cases: two simple prostate cases, one complex prostate Case, and one complex head and neck Case. When smaller numbers of decision criteria, more descriptive decision criteria, or less anti-correlated decision criteria were used to characterize plan quality during multiobjective optimization, dose to OARs and target dose variation were reduced in the final population of plans. Mean OAR dose and gEUD (a = 4) decision criteria were comparable. Using maximum dose decision criteria for OARs near targets resulted in inferior populations that focused solely on low target variance at the expense of high OAR dose. Target dose range, (D

  5. Feasibility Study of Moderately Accelerated Intensity-Modulated Radiotherapy Plus Concurrent Weekly Cisplatin After Induction Chemotherapy in Locally Advanced Head-and Neck Cancer

    International Nuclear Information System (INIS)

    Morganti, Alessio G.; Mignogna, Samantha; Deodato, Francesco; Massaccesi, Mariangela; Cilla, Savino; Calista, Franco; Serafini, Giovanni; Digesu, Cinzia; Macchia, Gabriella; Picardi, Vincenzo; Caravatta, Luciana; Di Lullo, Liberato; Giglio, Gianfranco; Sallustio, Giuseppina; Piermattei, Angelo

    2011-01-01

    Purpose: To evaluate the feasibility and efficacy of moderately accelerated intensity-modulated radiation therapy (IMRT) along with weekly cisplatin, after induction chemotherapy, in patients with locally advanced unresectable head and neck cancer (HNC). Methods and Materials: Patients with Stage III or IV locally advanced HNC, without progressive disease after three courses of induction chemotherapy, received concurrent chemo-IMRT (weekly cisplatin 30 mg/m 2 plus simultaneous integrated boost IMRT). A total of 67.5 Gy in 30 fractions were delivered to primary tumor and involved nodes, 60 Gy in 30 fractions to high-risk nodal areas, and 55.5 Gy in 30 fractions to low-risk nodal areas. Results: In all, 36 patients (median age, 56 years) with International Union Against Cancer (UICC) Stage III (n = 5) and IV (n = 31) were included. Of the 36 patients, 17 had received CF (cisplatin and 5-fluorouracil (CF) and 19 had received docetaxel cisplatin and 5-fluorouracil (DCF). During concurrent chemoradiation, 11 of 36 patients (30.5%) experienced Grade III mucositis (CF, 47%; DCF, 15%; p < 0.04). Grade III pharyngeal-esophageal toxicity was observed in 5 of 19 patients (26.3%; CF, 0.0%; DCF, 26.3%; p = 0.02). Two patients died of complications (5.5%). After chemoradiation, the complete response rate was 63.8%. Two-year local control was 88.7%. Two-year progression free survival and overall survival were 74.5% and 60.9%, respectively. Conclusions: In our experience, a moderately accelerated chemo-IMRT was feasible after induction chemotherapy. However, a noteworthy early death rate of 5.5% was observed. Intensive supportive care strategies should be defined to better manage radiation-induced toxic effects. Longer follow-up is required to determine the incidence of late radiation toxicities and tumor control rates.

  6. SU-E-T-643: Pure Alanine Dosimeter for Verification Dosimetry in IMRT

    International Nuclear Information System (INIS)

    Al-Karmi, Anan M.; Zraiqat, Fadi

    2015-01-01

    Purpose: The objective of this study was evaluation of accuracy of pure alanine dosimeters measuring intensity-modulated radiation therapy (IMRT) dose distributions in a thorax phantom. Methods: Alanine dosimeters were prepared in the form of 110 mg pure L-α-alanine powder filled into clear tissue-equivalent polymethylmethacrylate (PMMA) plastic tubes with the dimensions 25 mm length, 3 mm inner diameter, and 1 mm wall thickness. A dose-response calibration curve was established for the alanine by placing the dosimeters at 1.5 cm depth in a 30×30×30 cm 3 solid water phantom and then irradiating on a linac with 6 MV photon beam at 10×10 cm 2 field size to doses ranging from 1 to 5 Gy. Electron paramagnetic resonance (EPR) spectroscopy was used to determine the absorbed dose in alanine. An IMRT treatment plan was designed for a commercial heterogeneous CIRS thorax phantom and the dose values were calculated at three different points located in tissue, lung, and bone equivalent materials. A set of dose measurements was carried out to compare measured and calculated dose values by placing the alanine dosimeters at those selected locations inside the thorax phantom and delivering the IMRT to the phantom. Results: The alanine dose measurements and the IMRT plan dose calculations were found to be in agreement within ±2%. Specifically, the deviations were −0.5%, 1.3%, and −1.7% for tissue, lung, and bone; respectively. The slightly large deviations observed for lung and bone may be attributed to tissue inhomogeneity, steep dose gradients in these regions, and uncontrollable changes in spectrometer conditions. Conclusion: The results described herein confirmed that pure alanine dosimeter was suitable for in-phantom dosimetry of IMRT beams because of its high sensitivity and acceptable accuracy. This makes the dosimeter a promising option for quality control of the therapeutic beams, complementing the commonly used ionization chambers, TLDs, and films

  7. Comparison of whole-field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xiance; Yi, Jinling; Zhou, Yongqiang; Yan, Huawei; Han, Ce; Xie, Congying, E-mail: billy07@wzhospital.cn

    2013-01-01

    To study the feasibility of using volumetric-modulated arc therapy (VMAT) to deliver whole-field simultaneous integrated boost (WF-SIB) to treat patients with nasopharyngeal cancer (NPC). WF-SIB intensity-modulated radiotherapy (IMRT) plans, one-arc WF-SIB VMAT plans, and two-arc WF-SIB VMAT plans were generated with identical objective functions for 8 patients with NPC of various stages. Isodose distributions and dose-volume histograms were evaluated. Dosimetric and biological quality indices of clinical target volume (CTV) and organs at risk (OARs) were calculated to study the optimization capability of these 3 modalities in the treatment of patients with NPC. The optimization time, delivery time, required monitor units (MUs), and delivery accuracy were also compared to investigate the feasibility of these 3 modalities. There was no significant difference (p = 0.92) in target coverage (TC) between WF-SIB IMRT (99.00 ± 0.79) and two-arc WF-SIB VMAT (97.98 ± 1.29). However, both had higher TC than one-arc VMAT plans (89.92 ± 6.32, p < 0.01). IMRT demonstrated the best protection of the spinal cord, whereas two-arc VMAT showed the minimum D{sub max} to OARs. No other significant differences were observed among these 3 modalities on CTV coverage and OAR sparing. The delivery and MU efficiency of one-arc and two-arc WF-SIB VMAT were greatly improved compared with WF-SIB IMRT. The optimization time of one-arc and two-arc WF-SIB VMAT plans were 5 and 10 times greater than that of WF-SIB IMRT, respectively. The delivery accuracy of WF-SIB VMAT was not affected by the increased freedom. For patients with NPC, one-arc WF-SIB VMAT might not be able to achieve sufficient TC, whereas two-arc WF-SIB VMAT was able to achieve reasonable TC. No significant advantage on OAR protection was demonstrated by VMAT compared with IMRT. WF-SIB VMAT has significantly shorter delivery times, but WF-SIB IMRT may still be the first treatment choice for patients with NPC.

  8. The effects of tumor motion on planning and delivery of respiratory-gated IMRT

    International Nuclear Information System (INIS)

    Hugo, Geoffrey D.; Agazaryan, Nzhde; Solberg, Timothy D.

    2003-01-01

    The purpose of this study is to investigate the effects of object motion on the planning and delivery of IMRT. Two phantoms containing objects were imaged using CT under a variety of motion conditions. The effects of object motion on axial CT acquisition with and without gating were assessed qualitatively and quantitatively. Measurements of effective slice width and position for the CT scans were made. Mutual information image fusion was adapted for use as a quantitative measure of object deformation in CT images. IMRT plans were generated on the CT scans of the moving and gated object images. These plans were delivered with motion, with and without gating, and the delivery error between the moving deliveries and a nonmoving delivery was assessed using a scalable vector-based index. Motion during CT acquisition produces motion artifact, object deformation, and object mispositioning, which can be substantially reduced with gating. Objects that vary in cross section in the direction of motion exhibit the most deformation in CT images. Mutual information provides a useful quantitative estimate of object deformation. The delivery of IMRT in the presence of target motion significantly alters the delivered dose distribution in relation to the planned distribution. The utilization of gating for IMRT treatment, including imaging, planning, and delivery, significantly reduces the errors introduced by object motion

  9. TH-AB-BRA-07: PENELOPE-Based GPU-Accelerated Dose Calculation System Applied to MRI-Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Wang, Y; Mazur, T; Green, O; Hu, Y; Li, H; Rodriguez, V; Wooten, H; Yang, D; Zhao, T; Mutic, S; Li, H

    2016-01-01

    Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: We first translated PENELOPE from FORTRAN to C++ and validated that the translation produced equivalent results. Then we adapted the C++ code to CUDA in a workflow optimized for GPU architecture. We expanded upon the original code to include voxelized transport boosted by Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, we incorporated the vendor-provided MRIdian head model into the code. We performed a set of experimental measurements on MRIdian to examine the accuracy of both the head model and gPENELOPE, and then applied gPENELOPE toward independent validation of patient doses calculated by MRIdian’s KMC. Results: We achieve an average acceleration factor of 152 compared to the original single-thread FORTRAN implementation with the original accuracy preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen (1), mediastinum (1) and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: We developed a Monte Carlo simulation platform based on a GPU-accelerated version of PENELOPE. We validated that both the vendor provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and accumulation, IMRT optimization, and dosimetry system modeling for next generation MR-IGRT systems.

  10. TH-AB-BRA-07: PENELOPE-Based GPU-Accelerated Dose Calculation System Applied to MRI-Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y; Mazur, T; Green, O; Hu, Y; Li, H; Rodriguez, V; Wooten, H; Yang, D; Zhao, T; Mutic, S; Li, H [Washington University School of Medicine, Saint Louis, MO (United States)

    2016-06-15

    Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: We first translated PENELOPE from FORTRAN to C++ and validated that the translation produced equivalent results. Then we adapted the C++ code to CUDA in a workflow optimized for GPU architecture. We expanded upon the original code to include voxelized transport boosted by Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, we incorporated the vendor-provided MRIdian head model into the code. We performed a set of experimental measurements on MRIdian to examine the accuracy of both the head model and gPENELOPE, and then applied gPENELOPE toward independent validation of patient doses calculated by MRIdian’s KMC. Results: We achieve an average acceleration factor of 152 compared to the original single-thread FORTRAN implementation with the original accuracy preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen (1), mediastinum (1) and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: We developed a Monte Carlo simulation platform based on a GPU-accelerated version of PENELOPE. We validated that both the vendor provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and accumulation, IMRT optimization, and dosimetry system modeling for next generation MR-IGRT systems.

  11. Six years of experience in the planning and verification of the IMRT dynamics with portal dosimetry

    International Nuclear Information System (INIS)

    Molina Lopez, M. Y.; Pardo Perez, E.; Ruiz Maqueda, S.; Castro Novais, J.; Diaz Gavela, A. A.

    2013-01-01

    The objective of this study is the make a review of the method of verification of the IMRT throughout the 6 years of functioning of the service of-radiophysics and radiology protection, analyzing the parameters of each field evaluation to the 718 made IMRT during this period. (Author)

  12. Comparison of 3DCRT,VMAT and IMRT techniques in metastatic vertebra radiotherapy: A phantom Study

    Directory of Open Access Journals (Sweden)

    Gedik Sonay

    2017-01-01

    Full Text Available Vertebra metastases can be seen during the prognosis of cancer patients. Treatment ways of the metastasis are radiotherapy, chemotherapy and surgery. Three-dimensional conformal therapy (3D-CRT is widely used in the treatment of vertebra metastases. Also, Intensity Modulated Radiotherapy (IMRT and Volumetric Arc Therapy (VMAT are used too. The aim of this study is to examine the advantages and disadvantages of the different radiotherapy techniques. In the aspect of this goal, it is studied with a randophantom in Uludag University Medicine Faculty, Radiation Oncology Department. By using a computerized tomography image of the phantom, one 3DCRT plan, two VMAT and three IMRT plans for servical vertebra and three different 3DCRT plans, two VMAT and two IMRT plans for lomber vertebra are calculated. To calculate 3DCRT plans, CMS XiO Treatment System is used and to calculate VMAT and IMRT plans Monaco Treatment Planning System is used in the department. The study concludes with the dosimetric comparison of the treatment plans in the spect of critical organ doses, homogeneity and conformity index. As a result of this study, all critical organ doses are suitable for QUANTEC Dose Limit Report and critical organ doses depend on the techniques which used in radiotherapy. According to homogeneity and conformity indices, VMAT and IMRT plans are better than one in 3DCRT plans in servical and lomber vertebra radiotherapy plans.

  13. A dynamic supraclavicular field-matching technique for head-and-neck cancer patients treated with IMRT

    International Nuclear Information System (INIS)

    Duan, Jun; Shen Sui; Spencer, Sharon A.; Ahmed, Raef S.; Popple, Richard A.; Ye, Sung-Joon; Brezovich, Ivan A.

    2004-01-01

    Purpose: The conventional single-isocenter and half-beam (SIHB) technique for matching supraclavicular fields with head-and-neck (HN) intensity-modulated radiotherapy (IMRT) fields is subject to substantial dose inhomogeneities from imperfect accelerator jaw/MLC calibration. It also limits the isocenter location and restricts the useful field size for IMRT. We propose a dynamic field-matching technique to overcome these limitations. Methods and materials: The proposed dynamic field-matching technique makes use of wedge junctions for the abutment of supraclavicular and HN IMRT fields. The supraclavicular field was shaped with a multileaf collimator (MLC), which was orientated such that the leaves traveled along the superoinferior direction. The leaves that defined the superior field border moved continuously during treatment from 1.5 cm below to 1.5 cm above the conventional match line to generate a 3-cm-wide wedge-shaped junction. The HN IMRT fields were optimized by taking into account the dose contribution from the supraclavicular field to the junction area, which generates a complementary wedge to produce a smooth junction in the abutment region. This technique was evaluated on a polystyrene phantom and 10 HN cancer patients. Treatment plans were generated for the phantom and the 10 patients. Dose profiles across the abutment region were measured in the phantom on films. For patient plans, dose profiles that passed through the center of the neck lymph nodes were calculated using the proposed technique and the SIHB technique, and dose uniformity in the abutment region was compared. Field mismatches of ± 1 mm and ± 2 mm because of imperfect jaw/MLC calibration were simulated, and the resulting dose inhomogeneities were studied for the two techniques with film measurements and patient plans. Three-dimensional volumetric doses were analyzed, and equivalent uniform doses (EUD) were computed. The effect of field mismatches on EUD was compared for the two match

  14. Is it time to rethink the role of hyperfractionated radiotherapy in the management of children with newly-diagnosed brainstem glioma?: Results of a Pediatric Oncology Group Phase III trial comparing conventional VS. hyperfractionated radiotherapy

    International Nuclear Information System (INIS)

    Mandell, L.; Kadota, R.; Douglass, E.C.; Fontanesi, J.; Freeman, C.; Cohen, M.; Kovnar, E.; Burger, P.; Sanford, R.A.; Kepner, J.; Friedman, H.; Kun, L.

    1997-01-01

    Purposes/Objective: In June 1992, POG began accrual to a Phase III study, POG 9239, designed to compare the time to disease progression, overall survival, and toxicities observed in children with newly diagnosed brainstem glioma treated with 100 mg/m 2 of infusional Cisplatin and randomized to either conventional vs. hyperfractionated radiotherapy. The trial was closed in March 1996, having achieved its accrual goal. Materials and Methods: Patients (pts) eligible for study were those between 3 and 21 years of age with previously untreated tumors arising in the pons. Histologic confirmation of diagnosis was not mandatory, provided that the clinical and MRI scan findings were typical for diffusely infiltrating pontine glioma. Treatment (Rx) consisted of a six-week course of local field radiotherapy with either once a day treatment (Rx 1) of 180 cGy per fraction to a total dose of 5400 cGy or a twice a day regimen (Rx 2) of 117 cGy per fraction to a total dose of 7020 cGy (the second of the three hyperfractionated dose escalation levels of POG 8495). Because of previously reported poor results with conventional radiotherapy alone, Cisplatin was included as a potential radiosensitizer in an attempt to improve progression-free and ultimate survival rates. Based on results of the Phase I Cisplatin dose escalation trial, POG 9139, 100 mg/m 2 was chosen for this trial and was delivered by continuous infusion over a 120-hour period, beginning on the first day of radiotherapy and repeated during Weeks 3 and 5. Of the 132 pts accrued to the study, 94 are eligible for review based upon time since entry, 47 in each Rx arm. In Rx 1, there were 23 males and 24 females, ranging in age from 40 to 161 mo (median, 77 mo); in Rx 2, there were 20 males and 27 females, ranging in age from 41 to 212 mo (median, 77 mo). As of 4/18/96, the study coordinator had not yet verified eligibility and assessed the evaluability of the remaining pts. Results: All results are from time of diagnosis

  15. Lung damage following bone marrow transplantation after hyperfractionated total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Latini, Paolo; Aristei, Cynthia; Checcaglini, Franco; Maranzano, Ernesto; Panizza, B.M.; Perrucci, Elisabetta (University and Hospital, Policlinico, Perugia (Italy). Radiation Oncology Service); Aversa, Franco; Martelli, M.F. (University and Hospital, Policlinico, Perugia (Italy). Department of Haematology); Raymondi, Carlo (University and Hospital, Policlinico, Perugia (Italy). Radiation Physics Service)

    1991-10-01

    From July 1985 to December 1989, 72 evaluable patients aged 6-51 (median age 27) suffering from hematological malignancies received allo-geneic bone marrow transplant (BMT) depleted of T-lymphocytes to reduce risks of graft-versus-host-disease (GvHD); 57 were matched and 15 mis-matched. Three different conditioning regiments were used in an effort to enhance cytoreduction without increase extramedullary toxicity. Mis-matched patients were treated with more immunosuppressive regimens. Total body irradiation (TBI) was given in 3 doses/day, 5 h apart over 4 days for a total of 12 fractions. The dose to the lungs was 14.4, 15.6 and 9 Gy according to the conditioning regimen. The incidence of inter-stitial pneumonia (IP) was 12.3 percent in matched and 46.7 in mis-matched patients. The results seem to indicate that lung toxicity is correlated with the intensity of the conditioning regimen, the stage of disease and, in mismatched patients, with the degree of human leucocyte antigen (HLA) disparity and the poor post-BMT reconstitution, rather than the radiotherapy dose delivered to the lungs. On the contrary, the hyperfractionated scheme adopted, the absence of GvHD and, perhaps, the post-TBI administration of cyclophosphamide all seem to have contributed to the low incidence of IP in the matched patients. (author). 30 refs.; 5 figs.; 1 tab.

  16. Lung damage following bone marrow transplantation after hyperfractionated total body irradiation

    International Nuclear Information System (INIS)

    Latini, Paolo; Aristei, Cynthia; Checcaglini, Franco; Maranzano, Ernesto; Panizza, B.M.; Perrucci, Elisabetta; Aversa, Franco; Martelli, M.F.; Raymondi, Carlo

    1991-01-01

    From July 1985 to December 1989, 72 evaluable patients aged 6-51 (median age 27) suffering from hematological malignancies received allo-geneic bone marrow transplant (BMT) depleted of T-lymphocytes to reduce risks of graft-versus-host-disease (GvHD); 57 were matched and 15 mis-matched. Three different conditioning regiments were used in an effort to enhance cytoreduction without increase extramedullary toxicity. Mis-matched patients were treated with more immunosuppressive regimens. Total body irradiation (TBI) was given in 3 doses/day, 5 h apart over 4 days for a total of 12 fractions. The dose to the lungs was 14.4, 15.6 and 9 Gy according to the conditioning regimen. The incidence of inter-stitial pneumonia (IP) was 12.3 percent in matched and 46.7 in mis-matched patients. The results seem to indicate that lung toxicity is correlated with the intensity of the conditioning regimen, the stage of disease and, in mismatched patients, with the degree of human leucocyte antigen (HLA) disparity and the poor post-BMT reconstitution, rather than the radiotherapy dose delivered to the lungs. On the contrary, the hyperfractionated scheme adopted, the absence of GvHD and, perhaps, the post-TBI administration of cyclophosphamide all seem to have contributed to the low incidence of IP in the matched patients. (author). 30 refs.; 5 figs.; 1 tab

  17. Comparative study between IMRT planning and RapidArc® sliding window for head and neck tumors; Estudo comparativo de planejamento entre IMRT sliding window e RapidArc® para tumores de cabeca e pescoco

    Energy Technology Data Exchange (ETDEWEB)

    Pirani, Luiz F.; Silva, Leonardo P.; Lima, Marilia B.; Bittencourt, Guilherme R.; Ferreira, Anne Caroline M.; Batista, Delano V.S., E-mail: nando_lfp@yahoo.com.br [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2012-12-15

    This study aims to evaluate the RapidArc (RA) technique in the treatment of head and neck tumors and compare the results of treatments with intensity modulated radiation therapy (IMRT) in the National Cancer Institute (INCA). Head and neck carcinomas have a natural history with relative expansion to others regions, especially in advanced levels. Faster treatments, with better coverage of the Planning Target Volume (PTV) and sparing more risks organs (ROs) are necessary and bring a better clinical impact. Ten patients with head and neck cancer, planned with IMRT technique were replanned using the RA technique. Some dosimetric indexes were calculated for both techniques, with the intention of verifying which of them, at the same time, would promote greater coverage of the PTV and preserve more healthy tissue. In terms of coverage, both indexes were similar. The RA technique was more efficient for delivered doses to ROs. The number of monitor units (MU), number of fields and treatments time estimated were lower than IMRT technique. Finally, the results have showed that the RA technique clearly reduces the treatment time, reducing the average and maximum dose to ROs and conforming the target as IMRT technique. (author)

  18. Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Kwang-Ho; Kang, Sei-Kwon; Lee, MeYeon; Kim, Su SSan; Park, SoAh; Hwang, Tae-Jin; Kim, Kyoung Ju; Oh, Do Hoon; Bae, Hoonsik; Suh, Tae-Suk [Department of Radiation Oncology, Hallym University College of Medicine, Seoul, 431070 (Korea, Republic of) and Department of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 137701 (Korea, Republic of); Department of Radiation Oncology, Hallym University College of Medicine, Seoul 431070 (Korea, Republic of); Department of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 137701 (Korea, Republic of)

    2010-03-15

    Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

  19. Endocavitary in vivo Dosimetry for IMRT Treatments of Gynecologic Tumors

    International Nuclear Information System (INIS)

    Cilla, Savino; Macchia, Gabriella; Digesù, Cinzia; Deodato, Francesco; Sabatino, Domenico; Morganti, Alessio G.; Piermattei, Angelo

    2011-01-01

    The accuracy and reproducibility of endometrial carcinoma treatment with intensity-modulated radiotherapy (IMRT) was assessed by means of in vivo dosimetry. Six patients who had previously undergone radical hysterectomy for endometrial carcinoma were treated with IMRT using a vaginal applicator with radio-opaque fiducial markers. An ion-chamber inserted into the applicator supplied an endocavitary in vivo dosimetry for quality assurance purposes. The ratio R = D/D TPS between the in vivo measured dose D and the predicted dose by the treatment planning system D TPS was determined for every fraction of the treatment. Results showed that 90% and 100% of the ratios resulted equal to 1 within 5% and 10%, respectively. The mean value of the ratios distribution for the 6 patients was R = 0.995 and the SD = 0.034. The ratio R* between the measured and predicted total doses for each patient was near to 1, within 2%. The dosimetric results suggest that the use of a vaginal applicator in an image-guided approach could make the interfractions target position stable and reproducible, allowing a safe use of the IMRT technique in the treatment of postoperative vaginal vault. In vivo dosimetry may supply useful information about the discrimination of random vs. systematic errors. The workload is minimum and this in vivo dosimetry can be applied also in the clinical routine.

  20. Comparison of radiotherapy dosimetry for 3D-CRT, IMRT, and SBRT based on electron density calibration

    International Nuclear Information System (INIS)

    Kartutik, K; Pawiro, S A; Wibowo, W E

    2016-01-01

    Accurate calculation of dose distribution affected by inhomogeneity tissue is required in radiotherapy planning. This study was performed to determine the ratio between radiotherapy planning using 3D-CRT, IMRT, and SBRT based on a calibrated curve of CT-number in the lung for different target's shape in 3D-CRT, IMRT, and spinal cord for SBRT. Calibration curves of CT-number were generated under measurement basis and introduced into TPS, then planning was performed for 3D-CRT, IMRT, and SBRT with 7, and 15 radiation fields. Afterwards, planning evaluation was performed by comparing the DVH curve, HI, and CI. 3D-CRT and IMRT produced the lowest HI at calibration curve of CIRS 002LFC with the value 0.24 and 10. Whereas SBRT produced the lowest HI on a linear calibration curve with a value of 0.361. The highest CI in IMRT and SBRT technique achieved using a linear calibration curve was 0.97 and 1.77 respectively. For 3D-CRT, the highest CI was obtained by using calibration curve of CIRS 062M with the value of 0.45. From the results of CI and HI, it is concluded that the calibration curve of CT-number does not significantly differ with Schneider's calibrated curve, and inverse planning gives a better result than forward planning. (paper)

  1. Conventional patient specific IMRT QA and 3DVH verification of dose distribution for helical tomotherapy

    International Nuclear Information System (INIS)

    Sharma, Prabhat Krishna; Joshi, Kishore; Epili, D.; Gavake, Umesh; Paul, Siji; Reena, Ph.; Jamema, S.V.

    2016-01-01

    In recent years, patient-specific IMRT QA has transitioned from point dose measurements by ion chambers to films to 2D array measurements. 3DVH software has taken this transition a step further by estimating the 3D dose delivered to the patient volume from 2D diode measurements using a planned dose perturbation (PDP) algorithm. This algorithm was developed to determine, if the conventional IMRT QA though sensitive at detecting errors, has any predictive power in detecting dose errors of clinical significance related to dose to the target volume and organs at risk (OAR). The aim of this study is to compare the conventional IMRT patient specific QA and 3DVH dose distribution for patients treated with helical tomotherapy (HT)

  2. Department of Accelerator Physics and Technology: Overview

    International Nuclear Information System (INIS)

    Plawski, E.

    2004-01-01

    Full text: Due to the drastic reduction (in previous years) of scientific and technical staff of the Department, our basic work in 2003 was limited to the following subjects: - the development of radiographic 4 MeV electron accelerator, - computational verification of basic parameters of a simplified version of ''6/15 MeV'' medical accelerator. - continuation of the study of photon and electron spectra of narrow photon beams with the use of the BEAMnrc Monte Carlo codes, - a study of accelerating and deflecting travelling wave RF structures based on experience already gained. The small 4-6 MeV electron linac was constructed in the Department as a tool for radiographic services which may be offered by our Institute. In 2003, the most important sub-units of the accelerator were constructed and completed. Accelerated electron beam intensity up to 80 mA was already obtained and for the following year the energy spectrum measurement, energy and intensity optimisation for e - /X-ray conversion and also first exposures are planned. Because in the realisation of the 6/15 MeV Accelerator Project, the Department was responsible for calculations of beam guiding and acceleration (accelerating section with triode electron gun, beam focusing, achromatic deviation), last year some verifying computations were done. This concerned mainly the influence of the variation of gun injection energy and RF frequency shifts on beam dynamics. The computational codes written in the Department are still used and continuously developed for this and similar purposes. The triode gun, originally thought as a part of 6/15 MeV medical accelerator, is on long term testing, showing very good performance; a new pulse modulator for that sub-unit was designed. The Monte Carlo calculations of narrow photon beams are continued. Intensity modulated radiation therapy (IMRT) is expected to play a dominant role in the years to come. Our principal researcher hereafter receiving PhD degree collaborates on IMRT

  3. Aggressive simultaneous radiochemotherapy with cisplatin and paclitaxel in combination with accelerated hyperfractionated radiotherapy in locally advanced head and neck tumors. Results of a phase I-II trial

    Energy Technology Data Exchange (ETDEWEB)

    Kuhnt, T.; Pigorsch, S.; Pelz, T.; Haensgen, G.; Dunst, J. [Dept. of Radiotherapy, Martin Luther Univ., Halle (Germany); Becker, A. [Dept. of Radiotherapy, Martin Luther Univ., Halle (Germany); Dept. of Radiotherapy, Municipial Hospital, Dessau (Germany); Bloching, M.; Passmann, M. [Dept. of Head and Neck Surgery, Martin Luther Univ., Halle (Germany); Lotterer, E. [Dept. of Internal Medicine I, Martin Luther Univ., Halle (Germany)

    2003-10-01

    We have tested a very aggressive combination protocol with cisplatin and escalated paclitaxel in combination with accelerated hyperfractionated radiotherapy to assess the maximum tolerated dose (MTD), dose-limiting toxicity (DLT), overall toxicity, and response rate. Patients and Methods: The trial recruited 24 patients (21 males, three females, mean age 57 years) treated at our department from 1998 through 2001. Irradiation was administered in daily doses of 2 Gy up to 30 Gy followed by 1.4 Gy twice daily up to 70.6 Gy to the primary tumor and involved nodes and 51 Gy to the clinically negative regional nodes. The chemotherapy schedule included cisplatin in a fixed dose of 20 mg/m{sup 2} on days 1-5 and 29-33 and paclitaxel at increasing dose levels of 20, 25, 30 mg/m{sup 2} twice weekly over the whole treatment time. Patients were recruited in cohorts of three to six, and the MTD was reached if two out of six patients in one cohort developed DLT. DLT was defined as any grade 4 toxicity or any grade 3 toxicity requiring treatment interruption or unplanned hospitalization or any grade 3 neurotoxicity. We recruited mainly patients with large tumors for this protocol; all patients were stage IV, and the mean tumor volume (primary + metastases) amounted to 72 {+-} 61 cm{sup 3}. The mean follow-up was 30 months (range 4-39 months). Results: One early death (peritonitis and sepsis a t day 10) occurred, and 23 patients were evaluable for acute toxicity and response. The MTD of paclitaxel was reached at the third dose level (30 mg/m{sup 2} paclitaxel twice weekly). The DLT was severe mucositis grade 3 (n = 1) and skin erythema grade 4 (n = 2). After determining the MTD, another 14 patients were treated at the recommended dose level of paclitaxel with 25 mg/m{sup 2} twice weekly. In summary, 13/23 patients (57%) developed grade 3 and 10/23 (43%) grade 2 mucositis. Two patients (9%) had grade 4, five (22%) grade 3, and 16 (69%) grade 2 dermatitis. One patient died at day 30

  4. Aggressive simultaneous radiochemotherapy with cisplatin and paclitaxel in combination with accelerated hyperfractionated radiotherapy in locally advanced head and neck tumors. Results of a phase I-II trial

    International Nuclear Information System (INIS)

    Kuhnt, T.; Pigorsch, S.; Pelz, T.; Haensgen, G.; Dunst, J.; Becker, A.; Bloching, M.; Passmann, M.; Lotterer, E.

    2003-01-01

    We have tested a very aggressive combination protocol with cisplatin and escalated paclitaxel in combination with accelerated hyperfractionated radiotherapy to assess the maximum tolerated dose (MTD), dose-limiting toxicity (DLT), overall toxicity, and response rate. Patients and Methods: The trial recruited 24 patients (21 males, three females, mean age 57 years) treated at our department from 1998 through 2001. Irradiation was administered in daily doses of 2 Gy up to 30 Gy followed by 1.4 Gy twice daily up to 70.6 Gy to the primary tumor and involved nodes and 51 Gy to the clinically negative regional nodes. The chemotherapy schedule included cisplatin in a fixed dose of 20 mg/m 2 on days 1-5 and 29-33 and paclitaxel at increasing dose levels of 20, 25, 30 mg/m 2 twice weekly over the whole treatment time. Patients were recruited in cohorts of three to six, and the MTD was reached if two out of six patients in one cohort developed DLT. DLT was defined as any grade 4 toxicity or any grade 3 toxicity requiring treatment interruption or unplanned hospitalization or any grade 3 neurotoxicity. We recruited mainly patients with large tumors for this protocol; all patients were stage IV, and the mean tumor volume (primary + metastases) amounted to 72 ± 61 cm 3 . The mean follow-up was 30 months (range 4-39 months). Results: One early death (peritonitis and sepsis a t day 10) occurred, and 23 patients were evaluable for acute toxicity and response. The MTD of paclitaxel was reached at the third dose level (30 mg/m 2 paclitaxel twice weekly). The DLT was severe mucositis grade 3 (n = 1) and skin erythema grade 4 (n = 2). After determining the MTD, another 14 patients were treated at the recommended dose level of paclitaxel with 25 mg/m 2 twice weekly. In summary, 13/23 patients (57%) developed grade 3 and 10/23 (43%) grade 2 mucositis. Two patients (9%) had grade 4, five (22%) grade 3, and 16 (69%) grade 2 dermatitis. One patient died at day 30 of neutropenic infection

  5. Whole brain radiotherapy with adjuvant or concomitant boost in brain metastasis: dosimetric comparison between helical and volumetric IMRT technique

    International Nuclear Information System (INIS)

    Borghetti, Paolo; Pedretti, Sara; Spiazzi, Luigi; Avitabile, Rossella; Urpis, Mauro; Foscarini, Federica; Tesini, Giulia; Trevisan, Francesca; Ghirardelli, Paolo; Pandini, Sara Angela; Triggiani, Luca; Magrini, Stefano Maria; Buglione, Michela

    2016-01-01

    To compare and evaluate the possible advantages related to the use of VMAT and helical IMRT and two different modalities of boost delivering, adjuvant stereotactic boost (SRS) or simultaneous integrated boost (SIB), in the treatment of brain metastasis (BM) in RPA classes I-II patients. Ten patients were treated with helical IMRT, 5 of them with SRS after whole brain radiotherapy (WBRT) and 5 with SIB. MRI co-registration with planning CT was mandatory and prescribed doses were 30 Gy in 10 fractions (fr) for WBRT and 15Gy/1fr or 45Gy/10fr in SRS or SIB, respectively. For each patient, 4 “treatment plans” (VMAT SRS and SIB, helical IMRT SRS and SIB) were calculated and accepted if PTV boost was included in 95 % isodose and dose constraints of the main organs at risk were respected without major deviations. Homogeneity Index (HI), Conformal Index (CI) and Conformal Number (CN) were considered to compare the different plans. Moreover, time of treatment delivery was calculated and considered in the analysis. Volume of brain metastasis ranged between 1.43 and 51.01 cc (mean 12.89 ± 6.37 ml) and 3 patients had double lesions. V95% resulted over 95 % in the average for each kind of technique, but the “target coverage” was inadequate for VMAT planning with two sites. The HI resulted close to the ideal value of zero in all cases; VMAT-SIB, VMAT-SRS, Helical IMRT-SIB and Helical IMRT-SRS showed mean CI of 2.15, 2.10, 2.44 and 1.66, respectively (optimal range: 1.5–2.0). Helical IMRT-SRS was related to the best and reliable finding of CN (0.66). The mean of treatment time was 210 s, 467 s, 440 s, 1598 s, respectively, for VMAT-SIB, VMAT-SRS, Helical IMRT-SIB and Helical IMRT-SRS. This dosimetric comparison show that helical IMRT obtain better target coverage and respect of CI and CN; VMAT could be acceptable in solitary metastasis. SIB modality can be considered as a good choice for clinical and logistic compliance; literature’s preliminary data are confirming

  6. Simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) in nasopharyngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Studer, Gabriela [Dept. of Radiation Oncology, Univ. Hospital, Zurich (Switzerland); Peponi, Evangelia; Glanzmann, Christoph; Kunz, Guntram; Renner, Christoph; Tomuschat, Katja

    2010-03-15

    Purpose: To assess the efficacy and safety of using simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) to treat nasopharyngeal cancer (NPC) in a Caucasian cohort. Outcome was analyzed with respect to dose-volume histogram (DVH) values. Patients and Methods: Between 03/2002 and 01/2008, 39 NPC patients underwent SIB-IMRT (37 Caucasians; 31 males; mean age 53 years [16-78 years]). 41% presented with WHO (World Health Organization) type 1 unfavorable histology, 85% with stage III/IV disease. 19 patients had total gross tumor volume (GTV) 16-70 cm{sup 3} (mean 36 cm{sup 3}), while 16 had GTV > 70 cm{sup 3} (73-217 cm{sup 3}; mean 115 cm{sup 3}). All patients with stage II-IV disease received concomitant cisplatin. The prescribed SIB dose delivered to the planning target volume (PTV) was 70 Gy (2.00 Gy/fraction) in 17, 69.6 Gy (2.11 Gy/fraction) in 19, and 66 Gy (2.20 Gy/fraction) in three patients. Results: 3-year local relapse-free, nodal relapse-free, distant metastases-free, disease-free rates and overall survival were 86%, 89%, 85%, 72%, and 85% (median follow-up 30 months [8-71 months]). Histology was a significant prognostic factor concerning overall survival, with worst prognosis in WHO type 1 compared to type 2/3 (75% vs. 93%; p = 0.03). There was a trend in favor of WHO type 2/3 regarding local control (74% vs. 94%; p = 0.052). The PTV DVHs showed a slight left shift compared to reported series. Three patients developed grade 3 late effects (xerostomia [n=2], dysphagia [n=1], hearing loss [n=1]). Conclusion: In comparison with predominantly Asian NPC IMRT series in the literature, chemo-IMRT in the own Caucasian cohort, characterized by less radioresponsive WHO type 1, was equally effective. Treatment tolerance was excellent. (orig.)

  7. Monte Carlo investigation of collapsed versus rotated IMRT plan verification.

    Science.gov (United States)

    Conneely, Elaine; Alexander, Andrew; Ruo, Russell; Chung, Eunah; Seuntjens, Jan; Foley, Mark J

    2014-05-08

    IMRT QA requires, among other tests, a time-consuming process of measuring the absorbed dose, at least to a point, in a high-dose, low-dose-gradient region. Some clinics use a technique of measuring this dose with all beams delivered at a single gantry angle (collapsed delivery), as opposed to the beams delivered at the planned gantry angle (rotated delivery). We examined, established, and optimized Monte Carlo simulations of the dosimetry for IMRT verification of treatment plans for these two different delivery modes (collapsed versus rotated). The results of the simulations were compared to the treatment planning system dose calculations for the two delivery modes, as well as to measurements taken. This was done in order to investigate the validity of the use of a collapsed delivery technique for IMRT QA. The BEAMnrc, DOSXYZnrc, and egs_chamber codes were utilized for the Monte Carlo simulations along with the MMCTP system. A number of different plan complexity metrics were also used in the analysis of the dose distributions in a bid to qualify why verification in a collapsed delivery may or may not be optimal for IMRT QA. Following the Alfonso et al. formalism, the kfclin,frefQclin,Q correction factor was calculated to correct the deviation of small fields from the reference conditions used for beam calibration. We report on the results obtained for a cohort of 20 patients. The plan complexity was investigated for each plan using the complexity metrics of homogeneity index, conformity index, modulation complexity score, and the fraction of beams from a particular plan that intersect the chamber when performing the QA. Rotated QA gives more consistent results than the collapsed QA technique. The kfclin,frefQclin,Qfactor deviates less from 1 for rotated QA than for collapsed QA. If the homogeneity index is less than 0.05 then the kfclin,frefQclin,Q factor does not deviate from unity by more than 1%. A value this low for the homogeneity index can only be obtained

  8. IMRT treatment planning-A comparative inter-system and inter-centre planning exercise of the ESTRO QUASIMODO group

    International Nuclear Information System (INIS)

    Bohsung, Joerg; Gillis, Sofie; Arrans, Rafael; Bakai, Annemarie; De Wagter, Carlos; Knoeoes, Tommy; Mijnheer, Ben J.; Paiusco, Marta; Perrin, Bruce A.; Welleweerd, Hans; Williams, Peter

    2005-01-01

    Background and purpose: The purpose of this work was a comparison of realistic IMRT plans based on the same CT-image data set and a common predefined set of dose objectives for the planning target volume and the organs at risk. This work was part of the larger European QUASIMODO IMRT verification project. Materials and methods: Eleven IMRT plans were produced by nine different European groups, each applying a representative set of clinically used IMRT treatment planning systems. The plans produced were to be deliverable in a clinically acceptable treatment time with the local technical equipment. All plans were characterized using a set of different quality measures such as dose-volume histograms, number of monitor units and treatment time. Results: Only one plan was able to fulfil all dose objectives strictly; six plans failed some of the objectives but were still considered to be clinically acceptable; four plans were not able to reach the objectives. Additional quality scores such as the number of monitor units and treatment time showed large variations, which mainly depend on the delivery technique. Conclusion: The presented planning study showed that with nearly all presently available IMRT planning and delivery systems comparable dose distributions could be achieved if the planning goals are clearly defined in advance

  9. Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancer

    International Nuclear Information System (INIS)

    Mu, G; Ludlum, E; Xia, P

    2008-01-01

    The dosimetric impact of random and systematic multi-leaf collimator (MLC) leaf position errors is relatively unknown for head and neck intensity-modulated radiotherapy (IMRT) patients. In this report we studied 17 head and neck IMRT patients, including 12 treated with simple plans ( 100 segments). Random errors (-2 to +2 mm) and systematic errors (±0.5 mm and ±1 mm) in MLC leaf positions were introduced into the clinical plans and the resultant dose distributions were analyzed based on defined endpoint doses. The dosimetric effect was insignificant for random MLC leaf position errors up to 2 mm for both simple and complex plans. However, for systematic MLC leaf position errors, we found significant dosimetric differences between the simple and complex IMRT plans. For 1 mm systematic error, the average changes in D 95% were 4% in simple plans versus 8% in complex plans. The average changes in D 0.1cc of the spinal cord and brain stem were 4% in simple plans versus 12% in complex plans. The average changes in parotid glands were 9% in simple plans versus 13% for the complex plans. Overall, simple IMRT plans are less sensitive to leaf position errors than complex IMRT plans

  10. SU-F-T-391: Comparative Study of Treatment Planning Between IMRT and IMAT for Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Duan, J

    2016-01-01

    Purpose: The purpose of this study was to compare the dosimetric differences between intensitymodulated radiation therapy (IMRT) and intensity modulated arc therapy (IMAT) for malignant pleural mesothelioma (MPM) patients with regard to the sparing effect on organs at risk (OARs), plan quality, and delivery efficiency. Methods: Ten MPM patients were recruited in this study. To avoid the inter-operator variability, IMRT and IMAT plans for each patient were performed by one experienced dosimetrist. The treatment planning optimization process was carried out using the Eclipse 13.0 software. For a fair comparison, the planning target volume (PTV) coverage of the two plans was normalized to the same level. The treatment plans were evaluated on the following dosimetric variables: conformity index (CI) and homogeneity index (HI) for PTV, OARs dose, and the delivery efficiency for each plan. Results: All plans satisfied clinical requirements. The IMAT plans gained better CI and HI. The IMRT plans performed better sparing for heart and lung. Less MUs and control points were found in the IMAT plans. IMAT shortened delivery time compared with IMRT. Conclusion: For MPM, IMAT gains better conformity and homogeneity for PTV with IMRT, but increases the irradiation dose for OARs. IMAT shows an advantage in delivery efficiency.

  11. SU-F-T-391: Comparative Study of Treatment Planning Between IMRT and IMAT for Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Duan, J [Shandong Cancer Hospital and Institute, Jinan, Shandong province (China)

    2016-06-15

    Purpose: The purpose of this study was to compare the dosimetric differences between intensitymodulated radiation therapy (IMRT) and intensity modulated arc therapy (IMAT) for malignant pleural mesothelioma (MPM) patients with regard to the sparing effect on organs at risk (OARs), plan quality, and delivery efficiency. Methods: Ten MPM patients were recruited in this study. To avoid the inter-operator variability, IMRT and IMAT plans for each patient were performed by one experienced dosimetrist. The treatment planning optimization process was carried out using the Eclipse 13.0 software. For a fair comparison, the planning target volume (PTV) coverage of the two plans was normalized to the same level. The treatment plans were evaluated on the following dosimetric variables: conformity index (CI) and homogeneity index (HI) for PTV, OARs dose, and the delivery efficiency for each plan. Results: All plans satisfied clinical requirements. The IMAT plans gained better CI and HI. The IMRT plans performed better sparing for heart and lung. Less MUs and control points were found in the IMAT plans. IMAT shortened delivery time compared with IMRT. Conclusion: For MPM, IMAT gains better conformity and homogeneity for PTV with IMRT, but increases the irradiation dose for OARs. IMAT shows an advantage in delivery efficiency.

  12. Soft-Rt: software for IMRT simulations based on MCNPX

    International Nuclear Information System (INIS)

    Ferreira F, T. C.; Campos, T.

    2015-10-01

    Intensity Modulated Radiation Therapy (IMRT) is an advanced treatment technique, widely used in external radiotherapy. This paper presents the Soft-Rt which allows the simulation of an entire IMRT treatment protocol. The Soft-Rt performs a full three-dimensional rendering of a set of patient images, including the definitions of region of interest with organs in risk, and the target tumor volume and margins (PTV). Thus, a more accurate analysis and planning can be performed, taking into account the features and orientation of the radiation beams. The exposed tissues as well as the amount of absorbed dose is depicted in healthy and/or cancerous tissues. As conclusion, Soft-Rt can predict dose on the PTV accurately, preserving the surrounding healthy tissues. Soft-Rt is coupled with SISCODES code. The SISCODES code is firstly applied to segment the set of CT or MRI patient images in distinct tissues pointing out its respective density and chemical compositions. Later, the voxel model is export to the Soft-Rt IMRT planning module in which a full treatment planning is created. All geometrical parameters are sent to the general purpose Monte Carlo transport code - MCNP - to simulate the interaction of each incident beam towards to the PTV avoiding organs in risk. The normalized dose results are exported to the Soft-Rt out-module, in which the three-dimensional model visualization is shown in a transparent glass procedure adopting gray scale for the dependence on the mass density of the correlated tissue; while, a color scale to depict dose values in a superimpose protocol. (Author)

  13. Soft-Rt: software for IMRT simulations based on MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira F, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Campos, T., E-mail: tcff01@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Programa de Pos Graduacao em Ciencias e Tecnicas Nucleares, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Intensity Modulated Radiation Therapy (IMRT) is an advanced treatment technique, widely used in external radiotherapy. This paper presents the Soft-Rt which allows the simulation of an entire IMRT treatment protocol. The Soft-Rt performs a full three-dimensional rendering of a set of patient images, including the definitions of region of interest with organs in risk, and the target tumor volume and margins (PTV). Thus, a more accurate analysis and planning can be performed, taking into account the features and orientation of the radiation beams. The exposed tissues as well as the amount of absorbed dose is depicted in healthy and/or cancerous tissues. As conclusion, Soft-Rt can predict dose on the PTV accurately, preserving the surrounding healthy tissues. Soft-Rt is coupled with SISCODES code. The SISCODES code is firstly applied to segment the set of CT or MRI patient images in distinct tissues pointing out its respective density and chemical compositions. Later, the voxel model is export to the Soft-Rt IMRT planning module in which a full treatment planning is created. All geometrical parameters are sent to the general purpose Monte Carlo transport code - MCNP - to simulate the interaction of each incident beam towards to the PTV avoiding organs in risk. The normalized dose results are exported to the Soft-Rt out-module, in which the three-dimensional model visualization is shown in a transparent glass procedure adopting gray scale for the dependence on the mass density of the correlated tissue; while, a color scale to depict dose values in a superimpose protocol. (Author)

  14. IMRT treatment of anal cancer with a scrotal shield

    International Nuclear Information System (INIS)

    Hood, Rodney C.; Wu, Q. Jackie; McMahon, Ryan; Czito, Brian; Willett, Christopher

    2012-01-01

    The risk of sterility in males undergoing radiotherapy in the pelvic region indicates the use of a shielding device, which offers protection to the testes for patients wishing to maintain fertility. The use of such devices in the realm of intensity-modulated radiotherapy (IMRT) in the pelvic region can pose many obstacles during simulation, treatment planning, and delivery of radiotherapy. This work focuses on the development and execution of an IMRT plan for the treatment of anal cancer using a scrotal shielding device on a clinical patient. An IMRT plan was developed using Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA), using a wide array of gantry angles as well as fixed jaw and fluence editing techniques. When possible, the entire target volume was encompassed by the treatment field. When the beam was incident on the scrotal shield, the jaw was fixed to avoid the device and the collimator rotation optimized to irradiate as much of the target as possible. This technique maximizes genital sparing and allows minimal irradiation of the gonads. When this fixed-jaw technique was found to compromise adequate coverage of the target, manual fluence editing techniques were used to avoid the shielding device. Special procedures for simulation, imaging, and treatment verification were also developed. In vivo dosimetry was used to verify and ensure acceptable dose to the gonads. The combination of these techniques resulted in a highly conformal plan that spares organs and risk and avoids the genitals as well as entrance of primary radiation onto the shielding device.

  15. SU-F-J-124: Reduction in Dosimetric Impact of Motion Using VMAT Compared to IMRT in Hypofractionated Prostate Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ravindranath, B; Xiong, J; Happersett, L; Mageras, G; Zhang, P; Hunt, M [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: To quantify and compare the dosimetric impact of motion management correction strategies during VMAT and IMRT for hypofractionated prostate treatment. Methods: Two arc VMAT and 9 field IMRT plans were generated for two prostate cancer patients undergoing hypofractionated radiotherapy (7.5Gy × 5 and 8Gy × 5). 212 motion traces were retrospectively extracted from treatment records of prostate cancer patients with implanted Calypso beacons. Dose to the CTV and normal tissues was reconstructed for each trace and plan taking into account the actual treatment delivery time. Following motion correction scenarios were simulated: (1) VMAT plan – (a) No correction, (b) correction between arcs, (c) correction every 20 degrees of gantry rotation and (2) IMRT plan - (a) No correction,(b) correction between fields. Two mm action threshold for position correction was assumed. The 5–95% confidence interval (CI) range was extracted from the family of DVHs for each correction scenario. Results: Treatment duration for 8Gy plan (VMAT vs IMRT) was 3 vs 12 mins and for 7.5Gy plan was 3 vs 9 mins. In the absence of correction, the VMAT 5–−95% CI dose spread was, on average, less than the IMRT dose spread by 2% for CTVD95, 9% for rectalwall (RW) D1cc and 9% for bladderwall (BW) D53. Further, VMAT b/w arcs correction strategy reduced the spread about the planned value compared to IMRT b/w fields correction by: 1% for CTVD95, 2.6% for RW1cc and 2% for BWD53. VMAT 20 degree strategy led to greater reduction in dose spread compared to IMRT by: 2% for CTVD95, 4.5% for RW1cc and 6.7% for BWD53. Conclusion: In the absence of a correction strategy, the limited motion during VMAT’s shorter delivery times translates into less motion-induced dosimetric degradation than IMRT. Performing limited periodic motion correction during VMAT can yield excellent conformity to planned values that is superior to IMRT. This work was partially supported by Varian Medical Systems.

  16. A dosimetric selectivity intercomparison of HDR brachytherapy, IMRT and helical tomotherapy in prostate cancer radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hermesse, Johanne; Biver, Sylvie; Jansen, Nicolas; Coucke, Philippe [Dept. of Radiation Oncology, Liege Univ. Hospital (Belgium); Lenaerts, Eric [Dept. of Medical Physics, Liege Univ. Hospital (Belgium); De Patoul, Nathalie; Vynckier, Stefaan [Dept. of Medical Physics, St Luc Univ. Hospital, Brussels (Belgium); Scalliet, Pierre [Dept. of Radiation Oncology, St Luc Univ. Hospital, Brussels (Belgium); Nickers, Philippe [Dept. of Radiation Oncology, Oscar Lambret Center, Lille (France)

    2009-11-15

    Background and purpose: dose escalation in order to improve the biochemical control in prostate cancer requires the application of irradiation techniques with high conformality. The dosimetric selectivity of three radiation modalities is compared: high-dose-rate brachytherapy (HDR-BT), intensity-modulated radiation radiotherapy (IMRT), and helical tomotherapy (HT). Patients and methods: ten patients with prostate adenocarcinoma treated by a 10-Gy HDR-BT boost after external-beam radiotherapy were investigated. For each patient, HDR-BT, IMRT and HT theoretical treatment plans were realized using common contour sets. A 10-Gy dose was prescribed to the planning target volume (PTV). The PTVs and critical organs' dose-volume histograms obtained were compared using Student's t-test. Results: HDR-BT delivers spontaneously higher mean doses to the PTV with smaller cold spots compared to IMRT and HT. 33% of the rectal volume received a mean HDR-BT dose of 3.86 {+-} 0.3 Gy in comparison with a mean IMRT dose of 6.57 {+-} 0.68 Gy and a mean HT dose of 5.58 {+-} 0.71 Gy (p < 0.0001). HDR-BT also enables to better spare the bladder. The hot spots inside the urethra are greater with HDR-BT. The volume of healthy tissue receiving 10% of the prescribed dose is reduced at least by a factor of 8 with HDR-BT (p < 0.0001). Conclusion: HDR-BT offers better conformality in comparison with HT and IMRT and reduces the volume of healthy tissue receiving a low dose. (orig.)

  17. Poster - Thur Eve - 57: Craniospinal irradiation with jagged-junction IMRT approach without beam edge matching for field junctions.

    Science.gov (United States)

    Cao, F; Ramaseshan, R; Corns, R; Harrop, S; Nuraney, N; Steiner, P; Aldridge, S; Liu, M; Carolan, H; Agranovich, A; Karva, A

    2012-07-01

    Craniospinal irradiation were traditionally treated the central nervous system using two or three adjacent field sets. A intensity-modulated radiotherapy (IMRT) plan (Jagged-Junction IMRT) which overcomes problems associated with field junctions and beam edge matching, improves planning and treatment setup efficiencies with homogenous target dose distribution was developed. Jagged-Junction IMRT was retrospectively planned on three patients with prescription of 36 Gy in 20 fractions and compared to conventional treatment plans. Planning target volume (PTV) included the whole brain and spinal canal to the S3 vertebral level. The plan employed three field sets, each with a unique isocentre. One field set with seven fields treated the cranium. Two field sets treated the spine, each set using three fields. Fields from adjacent sets were overlapped and the optimization process smoothly integrated the dose inside the overlapped junction. For the Jagged-Junction IMRT plans vs conventional technique, average homogeneity index equaled 0.08±0.01 vs 0.12±0.02, and conformity number equaled 0.79±0.01 vs 0.47±0.12. The 95% isodose surface covered (99.5±0.3)% of the PTV vs (98.1±2.0)%. Both Jagged-Junction IMRT plans and the conventional plans had good sparing of the organs at risk. Jagged-Junction IMRT planning provided good dose homogeneity and conformity to the target while maintaining a low dose to the organs at risk. Jagged-Junction IMRT optimization smoothly distributed dose in the junction between field sets. Since there was no beam matching, this treatment technique is less likely to produce hot or cold spots at the junction in contrast to conventional techniques. © 2012 American Association of Physicists in Medicine.

  18. Stereotactic intensity-modulated radiation therapy (IMRT) and inverse treatment planning for advanced pleural mesothelioma. Feasibility and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Muenter, M.W.; Thilmann, C.; Hof, H.; Debus, J. [Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (dkfz), Heidelberg (Germany); Nill, S.; Hoess, A.; Partridge, M. [Dept. of Medical Physics, German Cancer Research Center (dkfz), Heidelberg (Germany); Haering, P. [Dept. of Central Dosimetry, German Cancer Research Center (dkfz), Heidelberg (Germany); Manegold, C. [Dept. of Medical Oncology/Internal Medicine, Thoraxklinik Heidelberg gGmbH, Heidelberg (Germany); Wannenmacher, M. [Dept. of Clinical Radiology, Univ. of Heidelberg, Heidelberg (Germany)

    2003-08-01

    Background and Purpose: Complex-shaped malignant pleural mesotheliomas (MPMs) with challenging volumes are extremely difficult to treat by conventional radiotherapy due to tolerance doses of the surrounding normal tissue. In a feasibility study, we evaluated if inversely planned stereotactic intensity-modulated radiation therapy (IMRT) could be applied in the treatment of MPM. Patients and Methods: Eight patients with unresectable lesions were treated after failure of chemotherapy. All patients were positioned using noninvasive patient fixation techniques which can be attached to the applied extracranial stereotactic system. Due to craniocaudal extension of the tumor, it was necessary to develop a special software attached to the inverse planning program KonRad, which can connect two inverse treatment plans and consider the applied dose of the first treatment plan in the area of the matchline of the second treatment plan. Results: Except for one patient, in whom radiotherapy was canceled due to abdominal metastasis, treatment could be completed in all patients and was well tolerated. Median survival after diagnosis was 20 months and after IMRT 6.5 months. Therefore, both the 1-year actuarial overall survival from the start of radiotherapy and the 2-year actuarial overall survival since diagnosis were 28%. IMRT did not result in clinically significant acute side effects. By using the described inverse planning software, over- or underdosage in the region of the field matchline could be prevented. Pure treatment time ranged between 10 and 21 min. Conclusion: This study showed that IMRT is feasible in advanced unresectable MPM. The presented possibilities of stereotactic IMRT in the treatment of MPM will justify the evaluation of IMRT in early-stage pleural mesothelioma combined with chemotherapy in a study protocol, in order to improve the outcome of these patients. Furthermore, dose escalation should be possible by using IMRT. (orig.)

  19. Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion

    International Nuclear Information System (INIS)

    Zhang Guowei; Jiang Ziping; Shepard, David; Zhang Bin; Yu, Cedric

    2006-01-01

    We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the dose distribution for the optimized IMRT plan was recalculated with the isocentre sampled from a predefined distribution in a Monte Carlo convolution/superposition dose engine with the breast simulated as a rigid object. The motion amplitudes applied in this study ranged from 0.5 to 2.0 cm. For a range of weighting levels assigned to the open field, comparisons were made between the static plans and the plans recalculated with motion. For the static plans, we found that uniform dose distributions could be generated with relative weights for the open segments equal to and below 80% and unacceptable levels of underdosage were observed with the weights larger than 80%. When simulated breathing motion was incorporated into the dose calculation, we observed a loss in dose uniformity as the weight of the open field was decreased to below 65%. More quantitatively, for each 1% decrease in the weight, the per cent volume of the target covered by at least 95% of the prescribed dose decreased by approximately 0.10% and 0.16% for motion amplitudes equal to 1.5 cm and 2.0 cm, respectively. When taking into account the

  20. Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields

    International Nuclear Information System (INIS)

    Hsu, Shu-Hui; Moran, Jean M.; Chen Yu; Kulasekere, Ravi; Roberson, Peter L.

    2010-01-01

    Purpose: Dose accuracy in the buildup region for radiotherapy treatment planning suffers from challenges in both measurement and calculation. This study investigates the dosimetry in the buildup region at normal and oblique incidences for open and IMRT fields and assesses the quality of the treatment planning calculations. Methods: This study was divided into three parts. First, percent depth doses and profiles (for 5x5, 10x10, 20x20, and 30x30 cm 2 field sizes at 0 deg., 45 deg., and 70 deg. incidences) were measured in the buildup region in Solid Water using an Attix parallel plate chamber and Kodak XV film, respectively. Second, the parameters in the empirical contamination (EC) term of the convolution/superposition (CVSP) calculation algorithm were fitted based on open field measurements. Finally, seven segmental head-and-neck IMRT fields were measured on a flat phantom geometry and compared to calculations using γ and dose-gradient compensation (C) indices to evaluate the impact of residual discrepancies and to assess the adequacy of the contamination term for IMRT fields. Results: Local deviations between measurements and calculations for open fields were within 1% and 4% in the buildup region for normal and oblique incidences, respectively. The C index with 5%/1 mm criteria for IMRT fields ranged from 89% to 99% and from 96% to 98% at 2 mm and 10 cm depths, respectively. The quality of agreement in the buildup region for open and IMRT fields is comparable to that in nonbuildup regions. Conclusions: The added EC term in CVSP was determined to be adequate for both open and IMRT fields. Due to the dependence of calculation accuracy on (1) EC modeling, (2) internal convolution and density grid sizes, (3) implementation details in the algorithm, and (4) the accuracy of measurements used for treatment planning system commissioning, the authors recommend an evaluation of the accuracy of near-surface dose calculations as a part of treatment planning commissioning.

  1. SU-F-T-378: Evaluation of Dose-Volume Variability and Parameters Between Prostate IMRT and VMAT Plans

    Energy Technology Data Exchange (ETDEWEB)

    Chow, J [Princess Margaret Cancer Centre, Toronto, ON (Canada); Jiang, R [Grand River Regional Cancer Centre, Kitchener, ON (Canada); Kiciak, A [University of Waterloo, Waterloo, ON (Canada)

    2016-06-15

    Purpose: This study compared the rectal dose-volume consistency, equivalent uniform dose (EUD) and normal tissue complication probability (NTCP) in prostate intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: For forty prostate IMRT and fifty VMAT patients treated using the same dose prescription (78 Gy/39 fraction) and dose-volume criteria in inverse planning optimization, the rectal EUD and NTCP were calculated for each patient. The rectal dose-volume consistency, showing the variability of dose-volume histogram (DVH) among patients, was defined and calculated based on the deviation between the mean and corresponding rectal DVH. Results: From both the prostate IMRT and VMAT plans, the rectal EUD and NTCP were found decreasing with the rectal volume. The decrease rates for the IMRT plans (EUD = 0.47 × 10{sup −3} Gy cm{sup −3} and NTCP = 3.94 × 10{sup −2} % cm{sup −3}) were higher than those for the VMAT (EUD = 0.28 × 10{sup −3} Gy cm{sup −3} and NTCP = 2.61 × 10{sup −2} % cm{sup −3}). In addition, the dependences of the rectal EUD and NTCP on the dose-volume consistency were found very similar between the prostate IMRT and VMAT plans. This shows that both delivery techniques have similar variations of the rectal EUD and NTCP on the dose-volume consistency. Conclusion: Dependences of the dose-volume consistency on the rectal EUD and NTCP were compared between the prostate IMRT and VMAT plans. It is concluded that both rectal EUD and NTCP decreased with an increase of the rectal volume. The variation rates of the rectal EUD and NTCP on the rectal volume were higher for the IMRT plans than VMAT. However, variations of the rectal dose-volume consistency on the rectal EUD and NTCP were found not significant for both delivery techniques.

  2. SU-E-T-163: Evaluation of Dose Distributions Recalculated with Per-Field Measurement Data Under the Condition of Respiratory Motion During IMRT for Liver Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Song, J; Yoon, M; Nam, T; Ahn, S; Chung, W [Chonnam National University Hwasun Hospital, Hwasun-kun, Chonnam (Korea, Republic of)

    2014-06-01

    Purpose: The dose distributions within the real volumes of tumor targets and critical organs during internal target volume-based intensity-modulated radiation therapy (ITV-IMRT) for liver cancer were recalculated by applying the effects of actual respiratory organ motion, and the dosimetric features were analyzed through comparison with gating IMRT (Gate-IMRT) plan results. Methods: The 4DCT data for 10 patients who had been treated with Gate-IMRT for liver cancer were selected to create ITV-IMRT plans. The ITV was created using MIM software, and a moving phantom was used to simulate respiratory motion. The period and range of respiratory motion were recorded in all patients from 4DCT-generated movie data, and the same period and range were applied when operating the dynamic phantom to realize coincident respiratory conditions in each patient. The doses were recalculated with a 3 dose-volume histogram (3DVH) program based on the per-field data measured with a MapCHECK2 2-dimensional diode detector array and compared with the DVHs calculated for the Gate-IMRT plan. Results: Although a sufficient prescription dose covered the PTV during ITV-IMRT delivery, the dose homogeneity in the PTV was inferior to that with the Gate-IMRT plan. We confirmed that there were higher doses to the organs-at-risk (OARs) with ITV-IMRT, as expected when using an enlarged field, but the increased dose to the spinal cord was not significant and the increased doses to the liver and kidney could be considered as minor when the reinforced constraints were applied during IMRT plan optimization. Conclusion: Because Gate-IMRT cannot always be considered an ideal method with which to correct the respiratory motional effect, given the dosimetric variations in the gating system application and the increased treatment time, a prior analysis for optimal IMRT method selection should be performed while considering the patient's respiratory condition and IMRT plan results.

  3. Integration method of 3D MR spectroscopy into treatment planning system for glioblastoma IMRT dose painting with integrated simultaneous boost

    International Nuclear Information System (INIS)

    Ken, Soléakhéna; Cassol, Emmanuelle; Delannes, Martine; Celsis, Pierre; Cohen-Jonathan, Elizabeth Moyal; Laprie, Anne; Vieillevigne, Laure; Franceries, Xavier; Simon, Luc; Supper, Caroline; Lotterie, Jean-Albert; Filleron, Thomas; Lubrano, Vincent; Berry, Isabelle

    2013-01-01

    To integrate 3D MR spectroscopy imaging (MRSI) in the treatment planning system (TPS) for glioblastoma dose painting to guide simultaneous integrated boost (SIB) in intensity-modulated radiation therapy (IMRT). For sixteen glioblastoma patients, we have simulated three types of dosimetry plans, one conventional plan of 60-Gy in 3D conformational radiotherapy (3D-CRT), one 60-Gy plan in IMRT and one 72-Gy plan in SIB-IMRT. All sixteen MRSI metabolic maps were integrated into TPS, using normalization with color-space conversion and threshold-based segmentation. The fusion between the metabolic maps and the planning CT scans were assessed. Dosimetry comparisons were performed between the different plans of 60-Gy 3D-CRT, 60-Gy IMRT and 72-Gy SIB-IMRT, the last plan was targeted on MRSI abnormalities and contrast enhancement (CE). Fusion assessment was performed for 160 transformations. It resulted in maximum differences <1.00 mm for translation parameters and ≤1.15° for rotation. Dosimetry plans of 72-Gy SIB-IMRT and 60-Gy IMRT showed a significantly decreased maximum dose to the brainstem (44.00 and 44.30 vs. 57.01 Gy) and decreased high dose-volumes to normal brain (19 and 20 vs. 23% and 7 and 7 vs. 12%) compared to 60-Gy 3D-CRT (p < 0.05). Delivering standard doses to conventional target and higher doses to new target volumes characterized by MRSI and CE is now possible and does not increase dose to organs at risk. MRSI and CE abnormalities are now integrated for glioblastoma SIB-IMRT, concomitant with temozolomide, in an ongoing multi-institutional phase-III clinical trial. Our method of MR spectroscopy maps integration to TPS is robust and reliable; integration to neuronavigation systems with this method could also improve glioblastoma resection or guide biopsies

  4. A dose planning study on applicator guided stereotactic IMRT boost in combination with 3D MRI based brachytherapy in locally advanced cervical cancer

    International Nuclear Information System (INIS)

    Assenholt, Marianne S.; Petersen, Joergen B.; Nielsen, Soeren K.; Lindegaard, Jacob C.; Tanderup, Kari

    2008-01-01

    Purpose. Locally advanced cervical cancer is usually treated with external beam radiotherapy followed by brachytherapy (BT). However, if response or tumour topography is unfavourable it may be difficult to reach a sufficient BT dose. The purpose of this study was to explore whether an applicator guided stereotactic IMRT boost could be combined with brachytherapy to improve dose volume parameters. Material and methods. Dose plans of 6 patients with HR CTV volumes of 31-100cc at the time of BT were analysed. MRI was performed with a combined intracavitary (IC)-interstitial (IS) ring applicator in situ. A radiotherapy schedule consisting of 45Gy (1.8Gyx25) IMRT followed by boost of 28Gy (7Gyx4fx) was modelled. Four different boost techniques were evaluated: IC-BT, IC/IS-BT, IC-BT+IMRT and IMRT. Dose plans were optimised for maximal tumour dose (D90) and coverage (V85Gy) while respecting DVH constraints in organs at risk: D2cc <75Gy in rectum and sigmoid and <90Gy in bladder (EQD2). In combined BT+IMRT dose plans, the IMRT plan was optimised on top of the BT dose distribution. Volumes irradiated to more than 60 Gy EQD2 (V60Gy) were evaluated. Results. Median dose coverage in IC plans was 74% [66-93%]. By using IC/IS or IC-BT+IMRT boost, the median coverage was improved to 95% [78-99%], and to 96% [69-99%] respectively. For IMRT alone, a median coverage of 98% [90-100%] was achieved, but V60Gy volumes were significantly increased by a median factor of 2.0 [1.4-2.3] as compared to IC/IS. It depended on the individual tumour topography whether IC/IS-BT or IC-BT+IMRT boost was the most favourable technique. Conclusion. It is technically possible to create dose plans that combine image guided BT and IMRT. In this study the dose coverage could be significantly increased by adding IS-BT or IMRT boost to the intracavitary dose. Using IMRT alone for boost cannot be advocated since this results in a significant increase of the volume irradiated to 60Gy

  5. Cardiac dose-sparing effects of deep-inspiration breath-hold in left breast irradiation. Is IMRT more beneficial than VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Sakka, Mazen; Grabenbauer, Gerhard G. [Coburg Cancer Center, Department of Radiation Oncology, Coburg (Germany); Friedrich-Alexander University of Erlangen-Nuernberg, Faculty of Medicine, Erlangen (Germany); Kunzelmann, Leonie; Metzger, Martin [Coburg Cancer Center, Department of Radiation Oncology, Coburg (Germany)

    2017-10-15

    Given the reduction in death from breast cancer, as well as improvements in overall survival, adjuvant radiotherapy is considered the standard treatment for breast cancer. However, left-sided breast irradiation was associated with an increased rate of fatal cardiovascular events due to incidental irradiation of the heart. Recently, considerable efforts have been made to minimize cardiac toxicity of left-sided breast irradiation by new treatment methods such as deep-inspiration breath-hold (DIBH) and new radiation techniques, particularly intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). The primary aim of this study was to evaluate the effect of DIBH irradiation on cardiac dose compared with free-breathing (FB) irradiation, while the secondary objective was to compare the advantages of IMRT versus VMAT plans in both the FB and the DIBH position for left-sided breast cancer. In all, 25 consecutive left-sided breast cancer patients underwent CT simulation in the FB and DIBH position. Five patients were excluded with no cardiac displacement following DIBH-CT simulation. The other 20 patients were irradiated in the DIBH position using respiratory gating. Four different treatment plans were generated for each patient, an IMRT and a VMAT plan in the DIBH and in the FB position, respectively. The following parameters were used for plan comparison: dose to the heart, left anterior descending coronary artery (mean dose, maximum dose, D25% and D45%), ipsilateral, contralateral lung (mean dose, D20%, D30%) and contralateral breast (mean dose). The percentage in dose reduction for organs at risk achieved by DIBH for both IMRT and VMAT plans was calculated and compared for each patient by each treatment plan. DIBH irradiation significantly reduced mean dose to the heart and left anterior descending coronary artery (LADCA) using both IMRT (heart -20%; p = 0.0002, LADCA -9%; p = 0.001) and VMAT (heart -23%; p = 0.00003, LADCA -16%; p = 0

  6. Radiotherapy-induced secondary cancer risk for breast cancer: 3D conformal therapy versus IMRT versus VMAT

    International Nuclear Information System (INIS)

    Lee, Boram; Sung, Jiwon; Yoon, Myonggeun; Lee, Sunyoung

    2014-01-01

    This study evaluated the secondary cancer risk to various organs due to radiation treatment for breast cancer. Organ doses to an anthropomorphic phantom were measured using a photoluminescent dosimeter (PLD) for breast cancer treatment with 3D conformal radiation therapy (3D-CRT), intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Cancer risk based on the measured dose was calculated using the BEIR (Biological Effects of Ionizing Radiation) VII models. The secondary dose per treatment dose (50.4 Gy) to various organs ranged from 0.02 to 0.36 Gy for 3D-CRT, but from 0.07 to 8.48 Gy for IMRT and VMAT, indicating that the latter methods are associated with higher secondary radiation doses than 3D-CRT. The result of the homogeneity index in the breast target shows that the dose homogeneity of 3D-CRT was worse than those of IMRT and VMAT. The organ specific lifetime attributable risks (LARs) to the thyroid, contralateral breast and ipsilateral lung per 100 000 population were 0.02, 19.71, and 0.76 respectively for 3D-CRT, much lower than the 0.11, 463.56, and 10.59 respectively for IMRT and the 0.12, 290.32, and 12.28 respectively for VMAT. The overall estimation of LAR indicated that the radiation-induced cancer risk due to breast radiation therapy was lower with 3D-CRT than with IMRT or VMAT. (paper)

  7. Optimization of dose distributions for adjuvant locoregional radiotherapy of gastric cancer by IMRT

    International Nuclear Information System (INIS)

    Lohr, F.; Dobler, B.; Mai, S.; Hermann, B.; Tiefenbacher, U.; Wieland, P.; Steil, V.; Wenz, F.

    2003-01-01

    Background and Purpose: Locoregional relapse is a problem frequently encountered with advanced gastric cancer. Data from the randomized Intergroup trial 116 suggest effectiveness of adjuvant radiochemotherapy, albeit with significant toxicity. The potential of intensity-modulated radiotherapy (IMRT) to reduce toxicity by significantly reducing maximum and median doses to organs at risk while still applying sufficient dose to the target volume in the upper abdomen was studied. Patient and Methods: For a typical configuration of target volumes and organs, a step-and-shoot IMRT plan (eight beam orientations), developed as a class solution for treatment of tumors in the upper abdomen (Figures 1 to 3), a conventional plan, a combination of the conventional plan with a kidney-sparing boost plan, and a conventional plan with noncoplanar ap and pa fields for improved kidney sparing were compared with respect to coverage of target volume and dose to organs at risk with a dose of 45 Gy delivered as the median dose to the target volume. Results: When using the conventional three-dimensionally planned box techniques, the right kidney could be kept below tolerance, but median dose to the left kidney amounted to between 14.8 and 26.9 Gy, depending on the plan. IMRT reduced the median dose to the left kidney to 10.5 Gy, while still keeping the dose to the right kidney 90% of prescription dose were delivered to > 90% of target volume with IMRT (Table 1). Conclusion: IMRT has the potential to deliver efficient doses to target volumes in the upper abdomen, while delivering dose to organs at risk in a more advantageous fashion than a conventional technique. For clinical implementation, the possibility of extensive organ motion in the upper abdomen has to be taken into account for treatment planning and patient positioning. The multitude of potential risks related to its application has to be the subject of thorough follow-up and further studies. (orig.)

  8. Advances in conformal radiotherapy using Monte Carlo Code to design new IMRT and IORT accelerators and interpret CT numbers

    CERN Document Server

    Wysocka-Rabin, A

    2013-01-01

    The introductory chapter of this monograph, which follows this Preface, provides an overview of radiotherapy and treatment planning. The main chapters that follow describe in detail three significant aspects of radiotherapy on which the author has focused her research efforts. Chapter 2 presents studies the author worked on at the German National Cancer Institute (DKFZ) in Heidelberg. These studies applied the Monte Carlo technique to investigate the feasibility of performing Intensity Modulated Radiotherapy (IMRT) by scanning with a narrow photon beam. This approach represents an alternative to techniques that generate beam modulation by absorption, such as MLC, individually-manufactured compensators, and special tomotherapy modulators. The technical realization of this concept required investigation of the influence of various design parameters on the final small photon beam. The photon beam to be scanned should have a diameter of approximately 5 mm at Source Surface Distance (SSD) distance, and the penumbr...

  9. IMRT implementation and patient specific dose verification with film and ion chamber array detectors

    International Nuclear Information System (INIS)

    Saminathan, S.; Manickam, R.; Chandraraj, V.; Supe, S. S.; Keshava, S. L.

    2009-01-01

    Implementation of Intensity Modulation Radiotherapy (IMRT) and patient dose verification was carried out with film and I'mariXX using linear accelerator with 120-leaf Millennium dynamic multi leaf collimator (dMLC). The basic mechanical and electrical commissioning and quality assurance tests of linear accelerator were carried out. The leaf position accuracy and leaf position repeatability checks were performed for static MLC positions. Picket fence test and garden fence test were performed to check the stability of the dMLC and the reproducibility of the gap between leaves. The radiation checks were performed to verify the position accuracy of MLCs in the collimator system. The dMLC dosimetric checks like output stability, average leaf transmission and dosimetric leaf separation were also investigated. The variation of output with gravitation at different gantry angles was found to be within 0.9%. The measured average leaf transmission for 6 MV was 1.6% and 1.8% for 18 MV beam. The dosimetric leaf separation was found to be 2.2 mm and 2.3 mm for 6 MV and 18 MV beams. In order to check the consistency of the stability and the precision of the dMLC, it is necessary to carryout regular weekly and monthly checks. The dynalog files analysis for Garden fence, leaf gap width and step wedge test patterns carried out weekly were in good agreement. Pretreatment verification was performed for 50 patients with ion chamber and I'matiXX device. The variations of calculated absolute dose for all treatment fields with the ion chamber measurement were within the acceptable criterion. Treatment Planning System (TPS) calculated dose distribution pattern was comparable with the I'matriXX measured dose distribution pattern. Out of 50 patients for which the comparison was made, 36 patients were agreed with the gamma pixel match of>95% and 14 patients were with the gamma pixel match of 90-95% with the criteria of 3% delta dose (DD) and 3 mm distance-to-agreement (DTA). Commissioning and

  10. GATE Monte Carlo simulation in radiation therapy for complex and dynamic beams in IMRT

    International Nuclear Information System (INIS)

    Benhalouche, Saadia

    2014-01-01

    Radiotherapy is one of the three methods of cancer treatment along with surgery and chemotherapy. It has evolved with the development of treatment techniques such as IMRT and VMAT along with IGRT for patient positioning. The aim is to effectively treat tumors while limiting the dose to healthy organs. In our work, we use the GATE Monte Carlo simulation platform to model a LINAC for a 6 MV photon beam. The resulting model is then validated with a dosimetric study by calculating relevant parameters for the beam quality. The LINAC model is then used for simulating clinical IMRT treatment plans in the ORL domain. Simulation results are compared with experimental measurements. We also explored the possibility of modeling the LINAC portal imaging system. This technique referred to as MV-CBCT combine the LINAC source with a flat panel detector to acquire 3D images of the patient. This part was validated first by acquiring 2D projections on patient and anthropomorphic phantom, and by reconstructing 3D volumes. Here again, validation was performed by comparing simulated and actual images. As a second step, a dosimetric validation was done by evaluating the dose deposited by IMRT beams, by means of portal signal only. We show in the present work the ability of GATE to perform complex IMRT treatments and portal images as they are performed routinely for dosimetric quality control. (author) [fr

  11. SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, R; Kamima, T [Cancer Institute Hospital of Japanese Foundation for Cancer Research, Koto, Tokyo (Japan); Tachibana, H [National Cancer Center, Kashiwa, Chiba (Japan)

    2016-06-15

    Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dose deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

  12. Radiation therapy technology innovations applied to the treatment of head and neck patients: - Clinical results of Intensity Modulated Radiotherapy (IMRT), - Contribution of Image Guided Radiotherapy (IGRT) in the management of head and neck patients treated with IMRT

    International Nuclear Information System (INIS)

    Graff-Cailleaud, Pierre

    2011-01-01

    Numerous and exciting technological innovations were recently developed in radiotherapy. We aimed to assess benefits in two specific fields. 1) Clinical results of Intensity Modulated Radiotherapy (IMRT) applied to the treatment of Head and Neck (H and N) patients. The first study was a long-term mono-centric prospective registration of all H and N patients treated with IMRT in our institution. Locoregional control was excellent and toxicities limited. Recurrences were in-field. Dosimetric recommendations (parotids mean dose) were established. The second study assessed the impact of IMRT on health-related quality of life for H and N patients through a multicentric matched-pair comparison with conventional radiotherapy. Outstanding benefits were observed particularly in the fields of salivary dysfunction and oral discomfort. 2) Contribution of Image Guided Radiotherapy (IGRT) in the management of H and N patients treated with IMRT. The first study was a monitoring of delivered dose, using 3D dose recalculation from Megavoltage Cone-Beam CT (CBCT), as a quality assurance measure of a panel of H and N IMRT patients aligned with IGRT. Dosimetric consequences of anatomical changes were assessed. Contribution of color-coded MVCBCT dose-difference maps was studied. The aim of the second study was to quantify the inherent relative mobility between anatomic regions of the H and N area and to assess the dosimetric impact of several different matching procedures. Recommendations for the use of CBCT images in a daily practice were established. (author) [fr

  13. Intensity modulated radiotherapy (IMRT in the treatment of children and Adolescents - a single institution's experience and a review of the literature

    Directory of Open Access Journals (Sweden)

    Huber Peter

    2009-09-01

    Full Text Available Abstract Background While IMRT is widely used in treating complex oncological cases in adults, it is not commonly used in pediatric radiation oncology for a variety of reasons. This report evaluates our 9 year experience using stereotactic-guided, inverse planned intensity-modulated radiotherapy (IMRT in children and adolescents in the context of the current literature. Methods Between 1999 and 2008 thirty-one children and adolescents with a mean age of 14.2 years (1.5 - 20.5 were treated with IMRT in our department. This heterogeneous group of patients consisted of 20 different tumor entities, with Ewing's sarcoma being the largest (5 patients, followed by juvenile nasopharyngeal fibroma, esthesioneuroblastoma and rhabdomyosarcoma (3 patients each. In addition a review of the available literature reporting on technology, quality, toxicity, outcome and concerns of IMRT was performed. Results With IMRT individualized dose distributions and excellent sparing of organs at risk were obtained in the most challenging cases. This was achieved at the cost of an increased volume of normal tissue receiving low radiation doses. Local control was achieved in 21 patients. 5 patients died due to progressive distant metastases. No severe acute or chronic toxicity was observed. Conclusion IMRT in the treatment of children and adolescents is feasible and was applied safely within the last 9 years at our institution. Several reports in literature show the excellent possibilities of IMRT in selective sparing of organs at risk and achieving local control. In selected cases the quality of IMRT plans increases the therapeutic ratio and outweighs the risk of potentially increased rates of secondary malignancies by the augmented low dose exposure.

  14. Comparison of dose distribution between 3DCRT and IMRT in middle thoracic and under thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Li Dingjie; Liu Hailong; Mao Ronghu; Liu Ru; Guo Xiaoqi; Lei Hongchang; Wang Jianhua

    2011-01-01

    Objective: To compare the dose distribution between three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) in treating esophageal carcinoma (middle thoracic section and under thoracic section) and to select reasonable treatment methods for esophagus cancer. Methods: Ten cases with cancer of the middle thoracic section and under thoracic section esophagus were chosen for a retrospective treatment-planning study. 3DCRT and IMRT plans were created for each patient: Some critical indicators were evolved in evaluating the treatment plans of IMRT (5B and 7B) and 3DCRT (3B), such as, PTV coverage and dose-volumes to irradiated normal structures. Evaluation indicators: prescription of 50 Gy. total lung volume (V5, V10, V20), mean lung dose (MLD), spinal cord (Dmax), heart (V40) and conformality index (CI). Each plan was evaluated with respect to dose distribution,dose-volume histograms (DVHs), and additional dosimetric endpoints described below. Results: There is no significance of CRT and IMRT technique in protection of total lung volume,mean lung dose, spinal cord (Dmax), target, CI and heart. Conclusion: As To radiotherapy of esophagus cancer of the middle thoracic section and under thoracic section, IMRT has no advantage compared with 3DCRT, the selection of plan should be adapted to the situations of every patient. (authors)

  15. Multi-institutional Comparison of Intensity Modulated Radiation Therapy (IMRT) Planning Strategies and Planning Results for Nasopharyngeal Cancer

    Science.gov (United States)

    Park, Sung Ho; Park, Suk Won; Oh, Do Hoon; Choi, Youngmin; Kim, Jeung Kee; Ahn, Yong Chan; Park, Won; Suh, Hyun Sook; Lee, Rena; Bae, Hoonsik

    2009-01-01

    The intensity-modulated radiation therapy (IMRT) planning strategies for nasopharyngeal cancer among Korean radiation oncology facilities were investigated. Five institutions with IMRT planning capacity using the same planning system were invited to participate in this study. The institutions were requested to produce the best plan possible for 2 cases that would deliver 70 Gy to the planning target volume of gross tumor (PTV1), 59.4 Gy to the PTV2, and 51.5 Gy to the PTV3 in which elective irradiation was required. The advised fractionation number was 33. The planning parameters, resultant dose distributions, and biological indices were compared. We found 2-3-fold variations in the volume of treatment targets. Similar degree of variation was found in the delineation of normal tissue. The physician-related factors in IMRT planning had more influence on the plan quality. The inhomogeneity index of PTV dose ranged from 4 to 49% in Case 1, and from 5 to 46% in Case 2. Variation in tumor control probabilities for the primary lesion and involved LNs was less marked. Normal tissue complication probabilities for parotid glands and skin showed marked variation. Results from this study suggest that greater efforts in providing training and continuing education in terms of IMRT planning parameters usually set by physician are necessary for the successful implementation of IMRT. PMID:19399266

  16. Dosimetric impact of interplay effect in lung IMRT and VMAT treatment using in-house dynamic thorax phantom

    International Nuclear Information System (INIS)

    Mukhlisin; Pawiro, S A

    2016-01-01

    Tumor motion due to patient's respiratory is a significant problem in radiotherapy treatment of lung cancer. The purpose of this project is to study the interplay effect through dosimetry verification between the calculated and delivered dose, as well as the dosimetric impact of leaf interplay with breathing-induced tumor motion in IMRT and VMAT treatment. In this study, a dynamic thorax phantom was designed and constructed for dosimetry measurement. The phantom had a linear sinusoidal tumor motion toward superior-inferior direction with variation of amplitudes and periods. TLD-100 LiF:Mg,Ti and Gafchromic EBT2 film were used to measure dose in the midpoint target and the spinal cord. The IMRT and VMAT treatment had prescription dose of 200 cGy per fraction. The dosimetric impact due to interplay effect during IMRT and VMAT treatment were resulted in the range of 0.5% to -6.6% and 0.9% to -5.3% of target dose reduction, respectively. Meanwhile, mean dose deviation of spinal cord in IMRT and VMAT treatment were around 1.0% to -6.9% and 0.9% to -6.3%, respectively. The results showed that if respiratory management technique were not implemented, the presence of lung tumor motion during dose delivery in IMRT and VMAT treatment causes dose discrepancies inside tumor volume. (paper)

  17. IMRT treatment of anal cancer with a scrotal shield.

    Science.gov (United States)

    Hood, Rodney C; Wu, Q Jackie; McMahon, Ryan; Czito, Brian; Willett, Christopher

    2012-01-01

    The risk of sterility in males undergoing radiotherapy in the pelvic region indicates the use of a shielding device, which offers protection to the testes for patients wishing to maintain fertility. The use of such devices in the realm of intensity-modulated radiotherapy (IMRT) in the pelvic region can pose many obstacles during simulation, treatment planning, and delivery of radiotherapy. This work focuses on the development and execution of an IMRT plan for the treatment of anal cancer using a scrotal shielding device on a clinical patient. An IMRT plan was developed using Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA), using a wide array of gantry angles as well as fixed jaw and fluence editing techniques. When possible, the entire target volume was encompassed by the treatment field. When the beam was incident on the scrotal shield, the jaw was fixed to avoid the device and the collimator rotation optimized to irradiate as much of the target as possible. This technique maximizes genital sparing and allows minimal irradiation of the gonads. When this fixed-jaw technique was found to compromise adequate coverage of the target, manual fluence editing techniques were used to avoid the shielding device. Special procedures for simulation, imaging, and treatment verification were also developed. In vivo dosimetry was used to verify and ensure acceptable dose to the gonads. The combination of these techniques resulted in a highly conformal plan that spares organs and risk and avoids the genitals as well as entrance of primary radiation onto the shielding device. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  18. NEOADJUVANT RADIOTHERAPY FOR BLADDER CARCINOMA IN ...

    African Journals Online (AJOL)

    Objective To evaluate the impact of preoperative accelerated hyperfractionated radiotherapy in the management of bladder carcinoma in Egyptian patients. Patients and Methods Between December 1996 and February 2000, 104 Egyptian patients with pathologically proven infiltrative bladder carcinoma were enrolled in ...

  19. Step-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Kaveh Shirani Tak Abi

    2015-05-01

    Full Text Available Introduction Intensity-Modulated Radiotherapy (IMRT is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the patient. The aim of the present study was to calculate and compare the integral dose in normal and target organs in two different procedures of IMRT: Step-and-Shoot (SAS and compensator-based IMRT. Materials and Methods In this comparative study, five patients with prostate cancer were selected. Module Integrated Radiotherapy System was applied, using three energy ranges. In both treatment planning methods, the integral dose dramatically decreased by increasing energy. Results Comparison of two treatment methods showed that on average, the integral dose of body in SAS radiation therapy was about 1.62% lower than that reported in compensator-based IMRT. In planning target volume, rectum, bladder, and left and right femoral heads, the integral doses for SAS method were 1.01%, 1.02%, 1.11%, 1.47%, and 1.40% lower than compensator-based IMRT, respectively. Conclusion Considering the treatment conditions, the definition of dose volume constraints for healthy tissues, and the equal volume of organs in both treatment methods, SAS radiation therapy by providing a lower integral dose seems to be more advantageous and efficient for prostate cancer treatment, compared to compensator-based IMRT.

  20. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian [Saarland University Medical School, Department of Radiotherapy and Radiation Oncology, Homburg/Saar (Germany)

    2016-02-15

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [German] Das Potenzial der intensitaetsmodulierten Strahlentherapie (IMRT) soll im Rahmen der FDG-PET basierten Bestrahlungsplanung des lokal fortgeschrittenen nichtkleinzelligen Bronchialkarzinoms (LA-NSCLC) fuer 2 Zielvolumenansaetze (Involved-Field-Bestrahlung, IF) sowie elektive Nodalbestrahlung (ENI) geprueft und mit der 3-D-konformalen Strahlentherapie (3-D

  1. Comparative study between IMRT planning and RapidArc® sliding window for head and neck tumors

    International Nuclear Information System (INIS)

    Pirani, Luiz F.; Silva, Leonardo P.; Lima, Marilia B.; Bittencourt, Guilherme R.; Ferreira, Anne Caroline M.; Batista, Delano V.S.

    2012-01-01

    This study aims to evaluate the RapidArc (RA) technique in the treatment of head and neck tumors and compare the results of treatments with intensity modulated radiation therapy (IMRT) in the National Cancer Institute (INCA). Head and neck carcinomas have a natural history with relative expansion to others regions, especially in advanced levels. Faster treatments, with better coverage of the Planning Target Volume (PTV) and sparing more risks organs (ROs) are necessary and bring a better clinical impact. Ten patients with head and neck cancer, planned with IMRT technique were replanned using the RA technique. Some dosimetric indexes were calculated for both techniques, with the intention of verifying which of them, at the same time, would promote greater coverage of the PTV and preserve more healthy tissue. In terms of coverage, both indexes were similar. The RA technique was more efficient for delivered doses to ROs. The number of monitor units (MU), number of fields and treatments time estimated were lower than IMRT technique. Finally, the results have showed that the RA technique clearly reduces the treatment time, reducing the average and maximum dose to ROs and conforming the target as IMRT technique. (author)

  2. Clinical and dosimetric evaluation of RapidArc versus standard sliding window IMRT in the treatment of head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Smet, Stephanie; Lambrecht, Maarten; Vanstraelen, Bianca; Nuyts, Sandra [University Hospitals Leuven, Department of Radiation Oncology, Leuven (Belgium)

    2014-08-29

    Several planning studies have already proven the substantial dosimetric advantages of RapidArc (RA) over standard intensity-modulated radiotherapy. We retrospectively compared RapidArc and standard sliding window IMRT (swIMRT) in locally advanced head and neck cancer, looking both at dosimetrics as well as toxicity and outcome. CT datasets of 78 patients treated with swIMRT and 79 patients treated with RA were included. To compare the resulting dose distributions, the dose-volume parameters were evaluated for the planning target volumes (PTVs), clinical target volumes (CTVs), and organs at risk (OARs), and the number of MU were calculated. Acute toxicity was assessed by the Common Toxicity Criteria version 3.0. PTV coverage with the 95 % isodose was slightly better for RA. Dose distribution has proven to be significantly more homogenous with RA and led to a reduction of 62 % in MU with better OAR sparing. As for toxicity, more grade 3 mucositis and dysphagia was observed for swIMRT, though we observed more grade 3 dermatitis for RA. In our retrospective analysis, RA had better target coverage and better sparing of the OAR. Overall, the grade of acute toxicity was lower for RA than for swIMRT for the same types of tumor locations, except for the grade of dermatitis. (orig.) [German] Mehrere Studien haben die dosimetrische Ueberlegenheit der RapidArc (RA) gegenueber der intensitaetsmodulierten Standard-Radiotherapie (IMRT) bereits gezeigt. In unserer Studie verglichen wir retrospektiv die RapidArc und die dynamische (''standard sliding window'') IMRT (swIMRT) bei lokal fortgeschrittenen Kopf-Hals-Karzinomen sowohl hinsichtlich dosimetrischer Daten als auchEffektivitaet und Toxizitaet. Die CT-Datenanalysen von 78 Patienten, die mit swIMRT behandelt wurden, und von 79 Patienten, welche RA erhalten hatten, wurden in die Studie aufgenommen. Um die darauf resultierenden applizierten Dosen vergleichen zu koennen, wurden die Dosis-Volumen-Parameter fuer

  3. Toxicity and outcome of pelvic IMRT for node-positive prostate cancer

    International Nuclear Information System (INIS)

    Mueller, A.C.; Luetjens, J.; Eckert, F.; Bamberg, M.; Alber, M.; Schilling, D.; Belka, C.; Gaswindt, U.

    2012-01-01

    Background and purpose: This study reports on the treatment techniques, toxicity, and outcome of pelvic intensity-modulated radiotherapy (IMRT) for lymph node-positive prostate cancer (LNPPC, T1-4, c/pN1 cM0). Patients and methods: Pelvic IMRT to 45-50.4 Gy was applied in 39 cases either after previous surgery of involved lymph nodes (n = 18) or with a radiation boost to suspicious nodes (n = 21) with doses of 60-70 Gy, usually combined with androgen deprivation (n = 37). The prostate and seminal vesicles received 70-74 Gy. In cases of previous prostatectomy, prostatic fossa and remnants of seminal vesicles were given 66-70 Gy. Treatment-related acute and late toxicity was graded according to the RTOG criteria. Results: Acute radiation-related toxicity higher than grade 2 occurred in 2 patients (with the need for urinary catheter/subileus related to adhesions after surgery). Late toxicity was mild (grade 1-2) after a median follow-up of 70 months. Over 50% of the patients reported no late morbidity (grade 0). PSA control and cancer-specific survival reached 67% and 97% at over 5 years. Conclusion: Pelvic IMRT after the removal of affected nodes or with a radiation boost to clinically positive nodes led to an acceptable late toxicity (no grade 3/4 events), thus justifying further evaluation of this approach in a larger cohort. (orig.)

  4. Plan averaging for multicriteria navigation of sliding window IMRT and VMAT

    International Nuclear Information System (INIS)

    Craft, David; Papp, Dávid; Unkelbach, Jan

    2014-01-01

    Purpose: To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. Methods: The authors show that by taking an appropriately defined average of leaf trajectories of sliding window plans, the authors obtain a sliding window plan whose fluence map is the exact average of the fluence maps corresponding to the initial plans. In the case of static-beam IMRT, this also implies that the dose distribution of the averaged plan is the exact dosimetric average of the initial plans. In VMAT delivery, the dose distribution of the averaged plan is a close approximation of the dosimetric average of the initial plans. Results: The authors demonstrate the method on three Pareto optimal VMAT plans created for a demanding paraspinal case, where the tumor surrounds the spinal cord. The results show that the leaf averaged plans yield dose distributions that approximate the dosimetric averages of the precomputed Pareto optimal plans well. Conclusions: The proposed method enables the navigation of deliverable Pareto optimal plans directly, i.e., interactive multicriteria exploration of deliverable sliding window IMRT and VMAT plans, eliminating the need for a sequencing step after navigation and hence the dose degradation that is caused by such a sequencing step

  5. Plan averaging for multicriteria navigation of sliding window IMRT and VMAT.

    Science.gov (United States)

    Craft, David; Papp, Dávid; Unkelbach, Jan

    2014-02-01

    To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. The authors show that by taking an appropriately defined average of leaf trajectories of sliding window plans, the authors obtain a sliding window plan whose fluence map is the exact average of the fluence maps corresponding to the initial plans. In the case of static-beam IMRT, this also implies that the dose distribution of the averaged plan is the exact dosimetric average of the initial plans. In VMAT delivery, the dose distribution of the averaged plan is a close approximation of the dosimetric average of the initial plans. The authors demonstrate the method on three Pareto optimal VMAT plans created for a demanding paraspinal case, where the tumor surrounds the spinal cord. The results show that the leaf averaged plans yield dose distributions that approximate the dosimetric averages of the precomputed Pareto optimal plans well. The proposed method enables the navigation of deliverable Pareto optimal plans directly, i.e., interactive multicriteria exploration of deliverable sliding window IMRT and VMAT plans, eliminating the need for a sequencing step after navigation and hence the dose degradation that is caused by such a sequencing step.

  6. Plan averaging for multicriteria navigation of sliding window IMRT and VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Craft, David, E-mail: dcraft@partners.org; Papp, Dávid; Unkelbach, Jan [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2014-02-15

    Purpose: To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. Methods: The authors show that by taking an appropriately defined average of leaf trajectories of sliding window plans, the authors obtain a sliding window plan whose fluence map is the exact average of the fluence maps corresponding to the initial plans. In the case of static-beam IMRT, this also implies that the dose distribution of the averaged plan is the exact dosimetric average of the initial plans. In VMAT delivery, the dose distribution of the averaged plan is a close approximation of the dosimetric average of the initial plans. Results: The authors demonstrate the method on three Pareto optimal VMAT plans created for a demanding paraspinal case, where the tumor surrounds the spinal cord. The results show that the leaf averaged plans yield dose distributions that approximate the dosimetric averages of the precomputed Pareto optimal plans well. Conclusions: The proposed method enables the navigation of deliverable Pareto optimal plans directly, i.e., interactive multicriteria exploration of deliverable sliding window IMRT and VMAT plans, eliminating the need for a sequencing step after navigation and hence the dose degradation that is caused by such a sequencing step.

  7. Minimizing Late Effects for Patients With Mediastinal Hodgkin Lymphoma: Deep Inspiration Breath-Hold, IMRT, or Both?

    Energy Technology Data Exchange (ETDEWEB)

    Aznar, Marianne C., E-mail: marianne.camille.aznar@regionh.dk [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Faculty of Sciences, Niels Bohr Institute, and Faculty of Health Sciences, University of Copenhagen, Copenhagen (Denmark); Maraldo, Maja V.; Schut, Deborah A. [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Lundemann, Michael [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Faculty of Sciences, Niels Bohr Institute, and Faculty of Health Sciences, University of Copenhagen, Copenhagen (Denmark); Brodin, N Patrik [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Institute of Onco-Physics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Vogelius, Ivan R. [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Berthelsen, Anne K. [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Specht, Lena; Petersen, Peter M. [Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-01

    Purpose: Hodgkin lymphoma (HL) survivors have an increased risk of cardiovascular disease (CD), lung cancer, and breast cancer. We investigated the risk for the development of CD and secondary lung, breast, and thyroid cancer after radiation therapy (RT) delivered with deep inspiration breath-hold (DIBH) compared with free-breathing (FB) using 3-dimensional conformal RT (3DCRT) and intensity modulated RT (IMRT). The aim of this study was to determine which treatment modality best reduced the combined risk of life-threatening late effects in patients with mediastinal HL. Methods and Materials: Twenty-two patients with early-stage mediastinal HL were eligible for the study. Treatment plans were calculated with both 3DCRT and IMRT on both DIBH and FB planning computed tomographic scans. We reported the estimated dose to the heart, lung, female breasts, and thyroid and calculated the estimated life years lost attributable to CD and to lung, breast, and thyroid cancer. Results: DIBH lowered the estimated dose to heart and lung regardless of delivery technique (P<.001). There was no significant difference between IMRT-FB and 3DCRT-DIBH in mean heart dose, heart V20Gy, and lung V20Gy. The mean breast dose was increased with IMRT regardless of breathing technique. Life years lost was lowest with DIBH and highest with FB. Conclusions: In this cohort, 3DCRT-DIBH resulted in lower estimated doses and lower lifetime excess risks than did IMRT-FB. Combining IMRT and DIBH could be beneficial for a subgroup of patients.

  8. Integral dose delivered to normal brain with conventional intensity-modulated radiotherapy (IMRT) and helical tomotherapy IMRT during partial brain radiotherapy for high-grade gliomas with and without selective sparing of the hippocampus, limbic circuit and neural stem cell compartment

    International Nuclear Information System (INIS)

    Marsh, James C.; Ziel, Ellis G; Diaz, Aidnag Z; Turian, Julius V; Wendt, Julie A.; Gobole, Rohit

    2013-01-01

    We compared integral dose with uninvolved brain (ID brain ) during partial brain radiotherapy (PBRT) for high-grade glioma patients using helical tomotherapy (HT) and seven field traditional inverse-planned intensity-modulated radiotherapy (IMRT) with and without selective sparing (SPA) of contralateral hippocampus, neural stem cell compartment (NSC) and limbic circuit. We prepared four PBRT treatment plans for four patients with high-grade gliomas (60Gy in 30 fractions delivered to planning treatment volume (PTV60Gy)). For all plans, a structure denoted 'uninvolved brain' was created, which included all brain tissue not part of PTV or standard (STD) organs at risk (OAR). No dosimetric constraints were included for uninvolved brain. Selective SPA plans were prepared with IMRT and HT; contralateral hippocampus, NSC and limbic circuit were contoured; and dosimetric constraints were entered for these structures without compromising dose to PTV or STD OAR. We compared V100 and D95 for PTV46Gy and PTV60Gy, and ID brain for all plans. There were no significant differences in V100 and D95 for PTV46Gy and PTV60Gy. ID brain was lower in traditional IMRT versus HT plans for STD and SPA plans (mean ID brain 23.64Gy vs. 28Gy and 18.7Gy vs. 24.5Gy, respectively) and in SPA versus STD plans both with IMRT and HT (18.7Gy vs. 23.64Gy and 24.5Gy vs. 28Gy, respectively). n the setting of PBRT for high-grade gliomas, IMRT reduces ID brain compared with HT with or without selective SPA of contralateral hippocampus, limbic circuit and NSC, and the use of selective SPA reduces ID brain compared with STD PBRT delivered with either traditional IMRT or HT.

  9. A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model

    International Nuclear Information System (INIS)

    Wang, Yuhe; Mazur, Thomas R.; Green, Olga; Hu, Yanle; Li, Hua; Rodriguez, Vivian; Wooten, H. Omar; Yang, Deshan; Zhao, Tianyu; Mutic, Sasa; Li, H. Harold

    2016-01-01

    Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: PENELOPE was first translated from FORTRAN to C++ and the result was confirmed to produce equivalent results to the original code. The C++ code was then adapted to CUDA in a workflow optimized for GPU architecture. The original code was expanded to include voxelized transport with Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, the vendor-provided MRIdian head model was incorporated into the code in an effort to apply gPENELOPE as both an accurate and rapid dose validation system. A set of experimental measurements were performed on the MRIdian system to examine the accuracy of both the head model and gPENELOPE. Ultimately, gPENELOPE was applied toward independent validation of patient doses calculated by MRIdian’s KMC. Results: An acceleration factor of 152 was achieved in comparison to the original single-thread FORTRAN implementation with the original accuracy being preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen(1), mediastinum (1), and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: A Monte Carlo simulation platform was developed based on a GPU- accelerated version of PENELOPE. This platform was used to validate that both the vendor-provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this

  10. A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model.

    Science.gov (United States)

    Wang, Yuhe; Mazur, Thomas R; Green, Olga; Hu, Yanle; Li, Hua; Rodriguez, Vivian; Wooten, H Omar; Yang, Deshan; Zhao, Tianyu; Mutic, Sasa; Li, H Harold

    2016-07-01

    The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on penelope and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. penelope was first translated from fortran to c++ and the result was confirmed to produce equivalent results to the original code. The c++ code was then adapted to cuda in a workflow optimized for GPU architecture. The original code was expanded to include voxelized transport with Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gpenelope highly user-friendly. Moreover, the vendor-provided MRIdian head model was incorporated into the code in an effort to apply gpenelope as both an accurate and rapid dose validation system. A set of experimental measurements were performed on the MRIdian system to examine the accuracy of both the head model and gpenelope. Ultimately, gpenelope was applied toward independent validation of patient doses calculated by MRIdian's kmc. An acceleration factor of 152 was achieved in comparison to the original single-thread fortran implementation with the original accuracy being preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen(1), mediastinum (1), and breast (1), the MRIdian dose calculation engine agrees with gpenelope with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). A Monte Carlo simulation platform was developed based on a GPU- accelerated version of penelope. This platform was used to validate that both the vendor-provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and

  11. A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuhe; Mazur, Thomas R.; Green, Olga; Hu, Yanle; Li, Hua; Rodriguez, Vivian; Wooten, H. Omar; Yang, Deshan; Zhao, Tianyu; Mutic, Sasa; Li, H. Harold, E-mail: hli@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110 (United States)

    2016-07-15

    Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: PENELOPE was first translated from FORTRAN to C++ and the result was confirmed to produce equivalent results to the original code. The C++ code was then adapted to CUDA in a workflow optimized for GPU architecture. The original code was expanded to include voxelized transport with Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, the vendor-provided MRIdian head model was incorporated into the code in an effort to apply gPENELOPE as both an accurate and rapid dose validation system. A set of experimental measurements were performed on the MRIdian system to examine the accuracy of both the head model and gPENELOPE. Ultimately, gPENELOPE was applied toward independent validation of patient doses calculated by MRIdian’s KMC. Results: An acceleration factor of 152 was achieved in comparison to the original single-thread FORTRAN implementation with the original accuracy being preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen(1), mediastinum (1), and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: A Monte Carlo simulation platform was developed based on a GPU- accelerated version of PENELOPE. This platform was used to validate that both the vendor-provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this

  12. Improving IMRT-plan quality with MLC leaf position refinement post plan optimization

    International Nuclear Information System (INIS)

    Niu Ying; Zhang Guowei; Berman, Barry L.; Parke, William C.; Yi Byongyong; Yu, Cedric X.

    2012-01-01

    Purpose: In intensity-modulated radiation therapy (IMRT) planning, reducing the pencil-beam size may lead to a significant improvement in dose conformity, but also increase the time needed for the dose calculation and plan optimization. The authors develop and evaluate a postoptimization refinement (POpR) method, which makes fine adjustments to the multileaf collimator (MLC) leaf positions after plan optimization, enhancing the spatial precision and improving the plan quality without a significant impact on the computational burden. Methods: The authors’ POpR method is implemented using a commercial treatment planning system based on direct aperture optimization. After an IMRT plan is optimized using pencil beams with regular pencil-beam step size, a greedy search is conducted by looping through all of the involved MLC leaves to see if moving the MLC leaf in or out by half of a pencil-beam step size will improve the objective function value. The half-sized pencil beams, which are used for updating dose distribution in the greedy search, are derived from the existing full-sized pencil beams without need for further pencil-beam dose calculations. A benchmark phantom case and a head-and-neck (HN) case are studied for testing the authors’ POpR method. Results: Using a benchmark phantom and a HN case, the authors have verified that their POpR method can be an efficient technique in the IMRT planning process. Effectiveness of POpR is confirmed by noting significant improvements in objective function values. Dosimetric benefits of POpR are comparable to those of using a finer pencil-beam size from the optimization start, but with far less computation and time. Conclusions: The POpR is a feasible and practical method to significantly improve IMRT-plan quality without compromising the planning efficiency.

  13. Cardiac dose-sparing effects of deep-inspiration breath-hold in left breast irradiation : Is IMRT more beneficial than VMAT?

    Science.gov (United States)

    Sakka, Mazen; Kunzelmann, Leonie; Metzger, Martin; Grabenbauer, Gerhard G

    2017-10-01

    Given the reduction in death from breast cancer, as well as improvements in overall survival, adjuvant radiotherapy is considered the standard treatment for breast cancer. However, left-sided breast irradiation was associated with an increased rate of fatal cardiovascular events due to incidental irradiation of the heart. Recently, considerable efforts have been made to minimize cardiac toxicity of left-sided breast irradiation by new treatment methods such as deep-inspiration breath-hold (DIBH) and new radiation techniques, particularly intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). The primary aim of this study was to evaluate the effect of DIBH irradiation on cardiac dose compared with free-breathing (FB) irradiation, while the secondary objective was to compare the advantages of IMRT versus VMAT plans in both the FB and the DIBH position for left-sided breast cancer. In all, 25 consecutive left-sided breast cancer patients underwent CT simulation in the FB and DIBH position. Five patients were excluded with no cardiac displacement following DIBH-CT simulation. The other 20 patients were irradiated in the DIBH position using respiratory gating. Four different treatment plans were generated for each patient, an IMRT and a VMAT plan in the DIBH and in the FB position, respectively. The following parameters were used for plan comparison: dose to the heart, left anterior descending coronary artery (mean dose, maximum dose, D25% and D45%), ipsilateral, contralateral lung (mean dose, D20%, D30%) and contralateral breast (mean dose). The percentage in dose reduction for organs at risk achieved by DIBH for both IMRT and VMAT plans was calculated and compared for each patient by each treatment plan. DIBH irradiation significantly reduced mean dose to the heart and left anterior descending coronary artery (LADCA) using both IMRT (heart -20%; p = 0.0002, LADCA -9%; p = 0.001) and VMAT (heart -23%; p = 0.00003, LADCA -16%; p = 0

  14. Multi-wire detector characterization for daily quality control on IMRT; Caracterizacao de um detector planar de multiplos fios para controle de qualidade diario de tratamentos com IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, Vilma A.; Watanabe, Erika Y.; Santos, Gabriela R.; Menegussi, Gisela, E-mail: vilmaferrari@uol.com.br [Instituto do Cancer do Estado de Sao Paulo (ICESP), SP (Brazil). Setor de Radioterapia

    2012-08-15

    Several dosimetry devices are being developed for quality control of radiation treatments using modern techniques as, for example, the Intensity Modulated Radiation Therapy (IMRT). The main function of these devices are to daily quality control of treatments of patients submitted to IMRT technique. The aim of this study is to characterize a type of planar multi-wire detector - DAVID (PTW) - for use in clinical practice. It was evaluated the influence of the system in the radiation beam by measuring the absorption factors and surface dose. We also analyzed the dose-linearity, reproducibility, the dependence with the dose rate and the angle of the linac head. Small errors in the position of the multi-leaf were inserted to evaluate the sensitivity of the system. The results showed that the detector can absorb up to 6.7% of the dose, depending of the energy beam and the field size. A significant increase in surface dose was observed, indicating that individual analysis is necessary for each patient. The system showed good reproducibility, linear response with dose, low dependence with dose rate and low dependence with the angle of the linac head. When small errors were inserted in the position of the multi-leaf, the system was able to detect them. Thus, the detector DAVID proved to be suitable for daily verification of IMRT treatments. (author)

  15. Local confidence limits for IMRT and VMAT techniques: a study based on TG119 test suite

    International Nuclear Information System (INIS)

    Thomas, M.; Chandroth, M.

    2014-01-01

    The aim of this study was to generate a local confidence limit (CL) for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques used at Waikato Regional Cancer Centre. This work was carried out based on the American Association of Physicists in Medicine (AAPM) Task Group (TG) 119 report. The AAPM TG 119 report recommends CLs as a bench mark for IMRT commissioning and delivery based on its multiple institutions planning and dosimetry comparisons. In this study the locally obtained CLs were compared to TG119 benchmarks. Furthermore, the same bench mark was used to test the capabilities and quality of the VMAT technique in our clinic. The TG 119 test suite consists of two primary and four clinical tests for evaluating the accuracy of IMRT planning and dose delivery systems. Pre defined structure sets contoured on computed tomography images were downloaded from AAPM website and were transferred to a locally designed phantom. For each test case two plans were generated using IMRT and VMAT optimisation. Dose prescriptions and planning objectives recommended by TG119 report were followed to generate the test plans in Eclipse Treatment Planning System. For each plan the point dose measurements were done using an ion chamber at high dose and low dose regions. The planar dose distribution was analysed for percentage of points passing the gamma criteria of 3 %/3 mm, for both the composite plan and individual fields of each plan. The CLs were generated based on the results from the gamma analysis and point dose measurements. For IMRT plans, the CLs obtained were (1) from point dose measurements: 2.49 % at high dose region and 2.95 % for the low dose region (2) from gamma analysis: 2.12 % for individual fields and 5.9 % for the composite plan. For VMAT plans, the CLs obtained were (1) from point dose measurements: 2.56 % at high dose region and 2.6 % for the low dose region (2) from gamma analysis: 1.46 % for individual fields and 0

  16. Investigation of the use of MOSFET for clinical IMRT dosimetric verification

    International Nuclear Information System (INIS)

    Chuang, Cynthia F.; Verhey, Lynn J.; Xia Ping

    2002-01-01

    With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advantage of a faster and simpler reading procedure compared to thermoluminescent dosimeters (TLD), and with the commercial MOSFET system, multiple detectors can be used simultaneously. In addition, the small size of the detector could be advantageous, especially for point dose measurements in small homogeneous dose regions. To evaluate the feasibility of MOSFET for routine IMRT dosimetry, a comprehensive set of experiments has been conducted, to investigate the stability, linearity, energy, and angular dependence. For a period of two weeks, under a standard measurement setup, the measured dose standard deviation using the MOSFETs was ±0.015 Gy with the mean dose being 1.00 Gy. For a measured dose range of 0.3 Gy to 4.2 Gy, the MOSFETs present a linear response, with a linearity coefficient of 0.998. Under a 10x10 cm 2 square field, the dose variations measured by the MOSFETs for every 10 degrees from 0 to 180 degrees is ±2.5%. The percent depth dose (PDD) measurements were used to verify the energy dependence. The measured PDD using the MOSFETs from 0.5 cm to 34 cm depth agreed to within ±3% when compared to that of the ionization chamber. For IMRT dose verification, two special phantoms were designed. One is a solid water slab with 81 possible MOSFET placement holes, and another is a cylindrical phantom with 48 placement holes. For each IMRT phantom verification, an ionization chamber and 3 to 5 MOSFETs were used to measure multiple point doses at different locations. Preliminary results show that the agreement between dose measured by MOSFET and that calculated by Corvus is within 5% error, while the agreement between ionization chamber measurement and the calculation is within 3% error. In conclusion, MOSFET detectors are suitable for

  17. Monte Carlo-based QA for IMRT of head and neck cancers

    Science.gov (United States)

    Tang, F.; Sham, J.; Ma, C.-M.; Li, J.-S.

    2007-06-01

    It is well-known that the presence of large air cavity in a dense medium (or patient) introduces significant electronic disequilibrium when irradiated with megavoltage X-ray field. This condition may worsen by the possible use of tiny beamlets in intensity-modulated radiation therapy (IMRT). Commercial treatment planning systems (TPSs), in particular those based on the pencil-beam method, do not provide accurate dose computation for the lungs and other cavity-laden body sites such as the head and neck. In this paper we present the use of Monte Carlo (MC) technique for dose re-calculation of IMRT of head and neck cancers. In our clinic, a turn-key software system is set up for MC calculation and comparison with TPS-calculated treatment plans as part of the quality assurance (QA) programme for IMRT delivery. A set of 10 off-the-self PCs is employed as the MC calculation engine with treatment plan parameters imported from the TPS via a graphical user interface (GUI) which also provides a platform for launching remote MC simulation and subsequent dose comparison with the TPS. The TPS-segmented intensity maps are used as input for the simulation hence skipping the time-consuming simulation of the multi-leaf collimator (MLC). The primary objective of this approach is to assess the accuracy of the TPS calculations in the presence of air cavities in the head and neck whereas the accuracy of leaf segmentation is verified by fluence measurement using a fluoroscopic camera-based imaging device. This measurement can also validate the correct transfer of intensity maps to the record and verify system. Comparisons between TPS and MC calculations of 6 MV IMRT for typical head and neck treatments review regional consistency in dose distribution except at and around the sinuses where our pencil-beam-based TPS sometimes over-predicts the dose by up to 10%, depending on the size of the cavities. In addition, dose re-buildup of up to 4% is observed at the posterior nasopharyngeal

  18. TU-C-17A-06: Evaluating IMRT Plan Deliverability Via PTV Shape and MLC Motion

    International Nuclear Information System (INIS)

    McGurk, R; Smith, VA; Price, M

    2014-01-01

    Purpose: For step-and-shoot intensity-modulated radiation therapy (IMRT) plans, the dosimetry and deliverability can be affected by the number and shape of the segments used. Thus, plan deliverability is likely related to target volume and shape. We investigated whether the sphericity of target volumes and the previously proposed Modulation Complexity Score (MCS) could be used together to improve the detection of IMRT fields that failed quality assurance (QA). Methods: 526 and 353 IMRT fields from 32 prostate and 28 head-and-neck (H'N) patients, respectively, were analyzed. MCS was used to quantify the complexity of multi-leaf collimator shapes and motion patterns for each field. Sphericity was calculated using the surface area and volume of each patient’s planning target volume (PTV). Logistic regression models with MCS-alone or MCS and sphericity terms were fit to PlanUNC IMRT pass/fail results (5% dose difference, 4mm distance-to-agreement criteria) using SAS 9.3 (Cary, NC). Model concordance, discordance and area under the curve (AUC) were used to quantify model accuracy. Results: Mean (±1 standard deviation) MCS for prostate and H'N were 0.58(±0.15) and 0.40 (±0.14), respectively. Mean sphericity scores were 0.75(±0.05) for prostate and 0.63 (±0.12) for H'N. Both metrics were significantly different between treatment locations (p<0.01, Wilcoxon Rank Sum Test) indicating greater complexity in shape and variations for H'N PTVs. For prostate, concordance, discordance and AUC using MCS alone were 80.8%, 18.7% and 0.811. Including sphericity in the model improved these to 81.7%, 17.7% and 0.820. For H'N, the original concordance, discordance and AUC were of 72.9%, 26.9% and 0.729. Including sphericity into the model improved these metrics to 76.5%, 23.2% and 0.729. Conclusion: Sphericity provides a quantitative measure of PTV shape. While improvement in IMRT QA failure detection was modest for both prostate and H'N plans

  19. Implementation of an integral program of quality assurance based on EPID to the IMRT

    International Nuclear Information System (INIS)

    Yannez Ruiz-Labrandera; Emilio; Gonzalez Perez, Y.

    2015-01-01

    We bring forward with this research the implementation of a procedure related to the assurance guaranty in the control of tue quality of IMRT treatment based on the technology of electronic portal images digital (EPID). For the sake of accomplishing quality controls, based in pylic digital images, we used like main tool the System of pylic digital images IviewGT TM with his application software. For the control of positioning of the multi-plates, we implemented a program in MATLAB, which yields the errors of positioning of the plates. For the dosimetric controls, the images obtained for the fields of treatment were climbed with the software ImageJ, and compared with the treatment planning systems (TPS) model Elekta's PrecisePlan ® for it we used the software Verisoft. We managed to implement a comprehensive program of quality control for IMRT. The positioning errors of the multiplates intervening bayouth's test younger errors of positioning under a 1m threw which the requisite is for the IMRT. The rest of the geometric proofs yielded favorable results inmail with them tolerance, same as the test Picket Fence. We verified 2 cases with the technique step and shoot, for it we verified 16 field, where gamma Index varied 85,8 - 98,9. It was checked the possibility to accomplish the quality controls for IMRT using pylic digital images, in our case checked itself himself I apply the Linac Elekta specify on the Ameijeiras. (Author)

  20. SU-F-T-388: Comparison of Biophysical Indices in Hippocampal-Avoidance Whole Brain VMAT and IMRT Radiation Therapy Treatment Plans

    International Nuclear Information System (INIS)

    Kendall, E; Ahmad, S; Algan, O; Higby, C; Hossain, S

    2016-01-01

    Purpose: To compare biophysical indices of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) treatment plans for whole brain radiation therapy following the NRG-CC001 protocol. Methods: In this retrospective study, a total of fifteen patients were planned with Varian Eclipse Treatment Planning System using VMAT (RapidArc) and IMRT techniques. The planning target volume (PTV) was defined as the whole brain volume excluding a uniform three-dimensional 5mm expansion of the hippocampus volume. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 95% of the target volume receiving 100% of the prescribed dose. The NRG Oncology protocol guidelines were followed for contouring and dose-volume constraints. A single radiation oncologist evaluated all treatment plans. Calculations of statistical significance were performed using Student’s paired t-test. Results: All VMAT and IMRT plans met the NRG-CC001 protocol dose-volume criteria. The average equivalent uniform dose (EUD) for the PTV for VMAT vs. IMRT was respectively (19.05±0.33 Gy vs. 19.38±0.47 Gy) for α/β of 2 Gy and (19.47±0.30 Gy vs. 19.84±0.42 Gy) for α/β of 10 Gy. For the PTV, the average mean and maximum doses were 2% and 5% lower in VMAT plans than in IMRT plans, respectively. The average EUD and the normal tissue complication probability (NTCP) for the hippocampus in VMAT vs. IMRT plans were (15.28±1.35 Gy vs. 15.65±0.99 Gy, p=0.18) and (0.305±0.012 Gy vs. 0.308±0.008 Gy, p=0.192), respectively. The average EUD and NTCP for the optic chiasm were both 2% higher in VMAT than in IMRT plans. Conclusion: Though statistically insignificant, VMAT plans indicate a lower hippocampus EUD than IMRT plans. Also, a small variation in NTCP was found between plans.

  1. SU-F-T-388: Comparison of Biophysical Indices in Hippocampal-Avoidance Whole Brain VMAT and IMRT Radiation Therapy Treatment Plans

    Energy Technology Data Exchange (ETDEWEB)

    Kendall, E; Ahmad, S; Algan, O; Higby, C; Hossain, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To compare biophysical indices of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) treatment plans for whole brain radiation therapy following the NRG-CC001 protocol. Methods: In this retrospective study, a total of fifteen patients were planned with Varian Eclipse Treatment Planning System using VMAT (RapidArc) and IMRT techniques. The planning target volume (PTV) was defined as the whole brain volume excluding a uniform three-dimensional 5mm expansion of the hippocampus volume. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 95% of the target volume receiving 100% of the prescribed dose. The NRG Oncology protocol guidelines were followed for contouring and dose-volume constraints. A single radiation oncologist evaluated all treatment plans. Calculations of statistical significance were performed using Student’s paired t-test. Results: All VMAT and IMRT plans met the NRG-CC001 protocol dose-volume criteria. The average equivalent uniform dose (EUD) for the PTV for VMAT vs. IMRT was respectively (19.05±0.33 Gy vs. 19.38±0.47 Gy) for α/β of 2 Gy and (19.47±0.30 Gy vs. 19.84±0.42 Gy) for α/β of 10 Gy. For the PTV, the average mean and maximum doses were 2% and 5% lower in VMAT plans than in IMRT plans, respectively. The average EUD and the normal tissue complication probability (NTCP) for the hippocampus in VMAT vs. IMRT plans were (15.28±1.35 Gy vs. 15.65±0.99 Gy, p=0.18) and (0.305±0.012 Gy vs. 0.308±0.008 Gy, p=0.192), respectively. The average EUD and NTCP for the optic chiasm were both 2% higher in VMAT than in IMRT plans. Conclusion: Though statistically insignificant, VMAT plans indicate a lower hippocampus EUD than IMRT plans. Also, a small variation in NTCP was found between plans.

  2. Imaging response is highly predictive of survival of malignant glioma patients treated with standard or hyperfractionated RT and carmustine in RTOG 9006

    International Nuclear Information System (INIS)

    Curran, Walter J.; Scott, Charles B.; Yung, W.K. Alfred; Scarantino, Charles; Urtasun, Raul; Movsas, Benjamin; Jones, Christopher; Simpson, Joseph; Fischbach, A. Jennifer; Petito, Carol; Nelson, James

    1996-01-01

    Objectives: Limited information is available correlating response to initial therapy and survival outcome among malignant glioma patients. This analysis was conducted to determine the response rate of malignant glioma patients to either standard (STN) or hyperfractionated (HFX) RT and carmustine and to correlate the tumor response status with survival. Patients and Methods: From (11(90)) to (3(94)), 712 newly diagnosed malignant glioma patients were registered on RTOG 9006 and randomized between hyperfractionated RT of 72.0 Gy in 1.2 Gy twice-daily fractions and 60.0 Gy in 2.0 Gy daily fractions. All patients received 80 mg/m-2 of carmustine D 1-3 q 8 wks. As reported in the 1996 Proceedings of the Amer Soc Clin Oncol (Abstr no. 280), there was no survival benefit observed for the HFX regimen. 529 of the 686 eligible patients had pre-operative, post-operative, and post-RT contrast-enhanced MR and/or CT scans available for central review of tumor and peritumoral edema measurements. Response status was judged by applying standard response criteria to a comparison of tumor measurements on follow-up and post-operative films. Results: Of the 529 patients evaluated for imaging response, the complete and partial response rates were 14% and 20%, respectively. A significant correlation between response and survival was observed (P<0.0001). Variables which predicted for a better tumor response were anaplastic astrocytoma vs glioblastoma multiforme histology, better performance status, more extensive resection, and a more favorable Recursive Partitioning and Amalgamation class assignment (JNCI 85:704-710, 1993). Conclusion: The objective response rate for malignant glioma patients to RTOG 9006 therapy was 34%, and survival outcome is strongly correlated with tumor response status. These observations justify the testing of aggressive salvage strategies for patients without imaging evidence of response following initial therapy

  3. Prone Hypofractionated Whole-Breast Radiotherapy Without a Boost to the Tumor Bed: Comparable Toxicity of IMRT Versus a 3D Conformal Technique

    Energy Technology Data Exchange (ETDEWEB)

    Hardee, Matthew E.; Raza, Shahzad; Becker, Stewart J.; Jozsef, Gabor; Lymberis, Stella C. [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States); Hochman, Tsivia; Goldberg, Judith D. [Division of Biostatistics, New York University School of Medicine, New York, NY (United States); DeWyngaert, Keith J. [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States); Formenti, Silvia C., E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States)

    2012-03-01

    Purpose: We report a comparison of the dosimetry and toxicity of three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT) among patients treated in the prone position with the same fractionation and target of the hypofractionation arm of the Canadian/Whelan trial. Methods and Materials: An institutional review board-approved protocol identified a consecutive series of early-stage breast cancer patients treated according to the Canadian hypofractionation regimen but in the prone position. Patients underwent IMRT treatment planning and treatment if the insurance carrier approved reimbursement for IMRT; in case of refusal, a 3D-CRT plan was used. A comparison of the dosimetric and toxicity outcomes during the acute, subacute, and long-term follow-up of the two treatment groups is reported. Results: We included 97 consecutive patients with 100 treatment plans in this study (3 patients with bilateral breast cancer); 40 patients were treated with 3D-CRT and 57 with IMRT. IMRT significantly reduced the maximum dose (Dmax median, 109.96% for 3D-CRT vs. 107.28% for IMRT; p < 0.0001, Wilcoxon test) and improved median dose homogeneity (median, 1.15 for 3D-CRT vs. 1.05 for IMRT; p < 0.0001, Wilcoxon test) when compared with 3D-CRT. Acute toxicity consisted primarily of Grade 1 to 2 dermatitis and occurred in 92% of patients. Grade 2 dermatitis occurred in 13% of patients in the 3D-CRT group and 2% in the IMRT group. IMRT moderately decreased rates of acute pruritus (p = 0.03, chi-square test) and Grade 2 to 3 subacute hyperpigmentation (p = 0.01, Fisher exact test). With a minimum of 6 months' follow-up, the treatment was similarly well tolerated in either group, including among women with large breast volumes. Conclusion: Hypofractionated breast radiotherapy is well tolerated when treating patients in the prone position, even among those with large breast volumes. Breast IMRT significantly improves dosimetry but yields only a modest

  4. SU-E-T-593: Outcomes and Toxicities From a Clinical Trial of APBI Using MERT+IMRT with the Same XMLC

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez-Ortega, E.; Ureba, A.; Barbeiro, A.R.; Baeza, J.A.; Plaza, A. Leal [Universidad de Sevilla, Departamento de Fisiologia Medica y Biofisica, Seville (Spain); Miguez-Sanchez, C.; Carrasco, F. [Hospital Universitario Virgen Macarena, Servicio de Radioterapia, Seville (Spain); Palma, B. [Stanford University, Department of Radiation Oncology, Stanford, CA (United States); Miras, H.; Arrans, R.

    2015-06-15

    Purpose: We present the results from a clinical trial of accelerated partial breast irradiation (APBI), using mixed modulated photon and electron beams (MERT+IMRT) with the same photon multileaf collimator (xMLC). Methods: Seven patients were enrolled in the first year of the APBI clinical trial. Patients were selected following the conditions included in the NSABP B-39/RTOG 0413 protocol. The targets and clinically relevant normal structures were contoured on the CT images following this protocol for APBI-EBRT. All treatments were delivered using combined modulated electron and photon beams by means of the same xMLC installed in a SIEMENS Primus linac, with a reduced SSD equal to 60 cm for electron beams. The plans were performed with a treatment planning system based on full Monte Carlo simulations, called CARMEN, developed by our group. Simultaneously, an alternative IMRT plan was calculated with the commercial TPS PINNACLE v8.0m (Philips), and both plans were compared. An ad-hoc breast phantom with semi-spherical geometry called NAOMI was designed for a specific QA protocol. Patients received a total dose of 38.5 Gy, delivered in 10 fractions over 5 consecutive days, with a twice-a-day hypofractionated schema.Follow-up visits during 2.5 years on average were repeated at 1 month post-treatment, every 3 months for the first year, and every 6 months for the second year. Toxicity was scored according to National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0). Results: This APBI technique achieved high loco-regional control rates and showed low acute toxicity (grade 1 of CTCAE) and no toxicities from first month onwards. Photographic assessment of cosmesis showed skin excellent results. Conclusion: The clinical results achieved with MERT+IMRT by using the same xMLC are comparable or even better than those obtained with other APBI techniques, thanks to a software solution without any additional equipment or specific device.

  5. SU-E-T-593: Outcomes and Toxicities From a Clinical Trial of APBI Using MERT+IMRT with the Same XMLC

    International Nuclear Information System (INIS)

    Jimenez-Ortega, E.; Ureba, A.; Barbeiro, A.R.; Baeza, J.A.; Plaza, A. Leal; Miguez-Sanchez, C.; Carrasco, F.; Palma, B.; Miras, H.; Arrans, R.

    2015-01-01

    Purpose: We present the results from a clinical trial of accelerated partial breast irradiation (APBI), using mixed modulated photon and electron beams (MERT+IMRT) with the same photon multileaf collimator (xMLC). Methods: Seven patients were enrolled in the first year of the APBI clinical trial. Patients were selected following the conditions included in the NSABP B-39/RTOG 0413 protocol. The targets and clinically relevant normal structures were contoured on the CT images following this protocol for APBI-EBRT. All treatments were delivered using combined modulated electron and photon beams by means of the same xMLC installed in a SIEMENS Primus linac, with a reduced SSD equal to 60 cm for electron beams. The plans were performed with a treatment planning system based on full Monte Carlo simulations, called CARMEN, developed by our group. Simultaneously, an alternative IMRT plan was calculated with the commercial TPS PINNACLE v8.0m (Philips), and both plans were compared. An ad-hoc breast phantom with semi-spherical geometry called NAOMI was designed for a specific QA protocol. Patients received a total dose of 38.5 Gy, delivered in 10 fractions over 5 consecutive days, with a twice-a-day hypofractionated schema.Follow-up visits during 2.5 years on average were repeated at 1 month post-treatment, every 3 months for the first year, and every 6 months for the second year. Toxicity was scored according to National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0). Results: This APBI technique achieved high loco-regional control rates and showed low acute toxicity (grade 1 of CTCAE) and no toxicities from first month onwards. Photographic assessment of cosmesis showed skin excellent results. Conclusion: The clinical results achieved with MERT+IMRT by using the same xMLC are comparable or even better than those obtained with other APBI techniques, thanks to a software solution without any additional equipment or specific device

  6. The development of intensity modulated radiotherapy (IMRT) for prostate cancer at Austin and Repatriation Medical Centre (ARMC)

    International Nuclear Information System (INIS)

    Joon, D.L.; Mantle, C.; Viotto, A.; Rolfo, A.; Rykers, K.; Fernando, W.; Grace, M.; Liu, G.; Quong, G.; Feigen, M.; Wada, M.; Joon, M.L.; Fogarty, G.; Chao, M.W.; Khoo, V.

    2003-01-01

    To describe the protocol development of the IMRT program for prostate cancer at the ARMC. A series of protocols were defined and developed to facilitate the delivery of intensity modulated radiotherapy for prostate cancer. These included the following: 1. Physical Simulation including bowel and bladder preparation and immobilization 2. Image Acquisition including CT and MRI simulation scans with image co-registration 3. Contouring Definitions including target and organ at risk volumes as well as IMRT optimization and evaluation volumes 4. Radiotherapy Planning including constraint definition, inverse planning and CMS Focus specific parameters 5. DICOM RT interface including data transfer between CMS Focus and the Elekta Linac Desktop record and verify system 6. Verification including action limits and pre-treatment online EPID verification 7. Radiotherapy Delivery being that of step and shoot 8. Quality Assurance including physics testing and documentation The protocol development and testing has lead to the precise clinical delivery of IMRT for prostate cancer at ARMC that exceeds most of the parameters that were previously measured with our conventional and 3D conformal radiotherapy. Further development is now underway to allow it to be implemented as the routine treatment of prostate cancer at ARMC. The clinical implementation of IMRT for prostate cancer involves a collaborative team approach including radiation oncologists, radiation therapists, and radiation physics. This is necessary to develop the appropriate protocols and quality assurance for precision radiotherapy that is required for IMRT

  7. A new plan quality index for nasopharyngeal cancer SIB IMRT.

    Science.gov (United States)

    Jin, X; Yi, J; Zhou, Y; Yan, H; Han, C; Xie, C

    2014-02-01

    A new plan quality index integrating dosimetric and radiobiological indices was proposed to facilitate the evaluation and comparison of simultaneous integrated boost (SIB) intensity modulated radiotherapy (IMRT) plans for nasopharyngeal cancer (NPC) patients. Ten NPC patients treated by SIB-IMRT were enrolled in the study. Custom software was developed to read dose-volume histogram (DVH) curves from the treatment planning system (TPS). A plan filtering matrix was introduced to filter plans that fail to satisfy treatment protocol. Target plan quality indices and organ at risk (OAR) plan quality indices were calculated for qualified plans. A unique composite plan quality index (CPQI) was proposed based on the relative weight of these indices to evaluate and compare competing plans. Plan ranking results were compared with detailed statistical analysis, radiation oncology quality system (ROQS) scoring results and physician's evaluation results to verify the accuracy of this new plan quality index. The average CPQI values for plans with OAR priority of low, normal, high, and PTV only were 0.22 ± 0.08, 0.49 ± 0.077, 0.71 ± 0.062, and -0.21 ± 0.16, respectively. There were significant differences among these plan quality indices (One-way ANOVA test, p plans were selected. Plan filtering matrix was able to speed up the plan evaluation process. The new matrix plan quality index CPQI showed good consistence with physician ranking results. It is a promising index for NPC SIB-IMRT plan evaluation. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization

    International Nuclear Information System (INIS)

    Siebers, Jeffrey V.; Lauterbach, Marc; Keall, Paul J.; Mohan, Radhe

    2002-01-01

    Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and characteristics of the MLC, the deliverable intensity distributions often differ from those produced by the optimizer, leading to differences between the delivered and the optimized doses. Objective function parameters are then adjusted empirically, and the plan is reoptimized to achieve a desired deliverable dose distribution. The resulting plan, though usually acceptable, may not be the best achievable. A method has been developed to incorporate the MLC restrictions into the optimization process. Our in-house IMRT system has been modified to include the calculation of the deliverable intensity into the optimizer. In this process, prior to dose calculation, the MLC leaf sequencer is used to convert intensities to dynamic MLC sequences, from which the deliverable intensities are then determined. All other optimization steps remain the same. To evaluate the effectiveness of deliverable-based optimization, 17 patient cases have been studied. Compared with standard optimization plus conversion to deliverable beams, deliverable-based optimization results show improved isodose coverage and a reduced dose to critical structures. Deliverable-based optimization results are close to the original nondeliverable optimization results, suggesting that IMRT can overcome the MLC limitations by adjusting individual beamlets. The use of deliverable-based optimization may reduce the need for empirical adjustment of objective function parameters and reoptimization of a plan to achieve desired results

  9. Verification of eye lens dose in IMRT by MOSFET measurement.

    Science.gov (United States)

    Wang, Xuetao; Li, Guangjun; Zhao, Jianling; Song, Ying; Xiao, Jianghong; Bai, Sen

    2018-04-17

    The eye lens is recognized as one of the most radiosensitive structures in the human body. The widespread use of intensity-modulated radiotherapy (IMRT) complicates dose verification and necessitates high standards of dose computation. The purpose of this work was to assess the computed dose accuracy of eye lens through measurements using a metal-oxide-semiconductor field-effect transistor (MOSFET) dosimetry system. Sixteen clinical IMRT plans of head and neck patients were copied to an anthropomorphic head phantom. Measurements were performed using the MOSFET dosimetry system based on the head phantom. Two MOSFET detectors were imbedded in the eyes of the head phantom as the left and the right lens, covered by approximately 5-mm-thick paraffin wax. The measurement results were compared with the calculated values with a dose grid size of 1 mm. Sixteen IMRT plans were delivered, and 32 measured lens doses were obtained for analysis. The MOSFET dosimetry system can be used to verify the lens dose, and our measurements showed that the treatment planning system used in our clinic can provide adequate dose assessment in eye lenses. The average discrepancy between measurement and calculation was 6.7 ± 3.4%, and the largest discrepancy was 14.3%, which met the acceptability criterion set by the American Association of Physicists in Medicine Task Group 53 for external beam calculation for multileaf collimator-shaped fields in buildup regions. Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  10. A randomized phase II/III study of adverse events between sequential (SEQ) versus simultaneous integrated boost (SIB) intensity modulated radiation therapy (IMRT) in nasopharyngeal carcinoma; preliminary result on acute adverse events.

    Science.gov (United States)

    Songthong, Anussara P; Kannarunimit, Danita; Chakkabat, Chakkapong; Lertbutsayanukul, Chawalit

    2015-08-08

    To investigate acute and late toxicities comparing sequential (SEQ-IMRT) versus simultaneous integrated boost intensity modulated radiotherapy (SIB-IMRT) in nasopharyngeal carcinoma (NPC) patients. Newly diagnosed stage I-IVB NPC patients were randomized to receive SEQ-IMRT or SIB-IMRT, with or without chemotherapy. SEQ-IMRT consisted of two sequential radiation treatment plans: 2 Gy x 25 fractions to low-risk planning target volume (PTV-LR) followed by 2 Gy x 10 fractions to high-risk planning target volume (PTV-HR). In contrast, SIB-IMRT consisted of only one treatment plan: 2.12 Gy and 1.7 Gy x 33 fractions to PTV-HR and PTV-LR, respectively. Toxicities were evaluated according to CTCAE version 4.0. Between October 2010 and November 2013, 122 eligible patients were randomized between SEQ-IMRT (54 patients) and SIB-IMRT (68 patients). With median follow-up time of 16.8 months, there was no significant difference in toxicities between the two IMRT techniques. During chemoradiation, the most common grade 3-5 acute toxicities were mucositis (15.4% vs 13.6%, SEQ vs SIB, p = 0.788) followed by dysphagia (9.6% vs 9.1%, p = 1.000) and xerostomia (9.6% vs 7.6%, p = 0.748). During the adjuvant chemotherapy period, 25.6% and 32.7% experienced grade 3 weight loss in SEQ-IMRT and SIB-IMRT (p = 0.459). One-year overall survival (OS) and progression-free survival (PFS) were 95.8% and 95.5% in SEQ-IMRT and 98% and 90.2% in SIB-IMRT, respectively (p = 0.472 for OS and 0.069 for PFS). This randomized, phase II/III trial comparing SIB-IMRT versus SEQ-IMRT in NPC showed no statistically significant difference between both IMRT techniques in terms of acute adverse events. Short-term tumor control and survival outcome were promising.

  11. A randomized phase II/III study of adverse events between sequential (SEQ) versus simultaneous integrated boost (SIB) intensity modulated radiation therapy (IMRT) in nasopharyngeal carcinoma; preliminary result on acute adverse events

    International Nuclear Information System (INIS)

    Songthong, Anussara P.; Kannarunimit, Danita; Chakkabat, Chakkapong; Lertbutsayanukul, Chawalit

    2015-01-01

    To investigate acute and late toxicities comparing sequential (SEQ-IMRT) versus simultaneous integrated boost intensity modulated radiotherapy (SIB-IMRT) in nasopharyngeal carcinoma (NPC) patients. Newly diagnosed stage I-IVB NPC patients were randomized to receive SEQ-IMRT or SIB-IMRT, with or without chemotherapy. SEQ-IMRT consisted of two sequential radiation treatment plans: 2Gy x 25 fractions to low-risk planning target volume (PTV-LR) followed by 2Gy x 10 fractions to high-risk planning target volume (PTV-HR). In contrast, SIB-IMRT consisted of only one treatment plan: 2.12Gy and 1.7Gy x 33 fractions to PTV-HR and PTV-LR, respectively. Toxicities were evaluated according to CTCAE version 4.0. Between October 2010 and November 2013, 122 eligible patients were randomized between SEQ-IMRT (54 patients) and SIB-IMRT (68 patients). With median follow-up time of 16.8 months, there was no significant difference in toxicities between the two IMRT techniques. During chemoradiation, the most common grade 3–5 acute toxicities were mucositis (15.4 % vs 13.6 %, SEQ vs SIB, p = 0.788) followed by dysphagia (9.6 % vs 9.1 %, p = 1.000) and xerostomia (9.6 % vs 7.6 %, p = 0.748). During the adjuvant chemotherapy period, 25.6 % and 32.7 % experienced grade 3 weight loss in SEQ-IMRT and SIB-IMRT (p = 0.459). One-year overall survival (OS) and progression-free survival (PFS) were 95.8 % and 95.5 % in SEQ-IMRT and 98 % and 90.2 % in SIB-IMRT, respectively (p = 0.472 for OS and 0.069 for PFS). This randomized, phase II/III trial comparing SIB-IMRT versus SEQ-IMRT in NPC showed no statistically significant difference between both IMRT techniques in terms of acute adverse events. Short-term tumor control and survival outcome were promising

  12. An inter-centre quality assurance network for IMRT verification: Results of the ESTRO QUASIMODO project

    International Nuclear Information System (INIS)

    Gillis, Sofie; Wagter, Carlos de; Bohsung, Joerg; Perrin, Bruce; Williams, Peter; Mijnheer, Ben J.

    2005-01-01

    Background and purpose: IMRT necessitates extension of existing inter-centre quality assurance programs due to its increased complexity. We assessed the feasibility of an inter-centre verification method for different IMRT techniques. Materials and methods: Eight European radiotherapy institutions of the QUASIMODO network, have designed an IMRT plan for a horseshoe-shaped PTV surrounding a cylindrical OAR in a simplified pelvic phantom. All centres applied common plan objectives but used their own equipment for planning and delivery. They verified the delivery of this plan according to a common protocol with radiographic film and ionisation chamber measurements. The irradiated films, the results of the ionisation chamber measurements and the computed dose distributions were sent to one analysis centre that compared the measured and computed dose distributions with the gamma method and composite dose-area histograms. Results: 4% (relative to the prescribed dose) and 3 mm (distance-to-agreement) were decided feasible gamma criteria. The composite dose-area histograms showed a maximum local deviation of 3.5% in the mean dose of the PTV and 5% in the OAR. Systematic differences could be identified, and in some cases explained. Conclusions: This multi-centre dosimetric verification study demonstrated both the feasibility of a multi-centre quality assurance network to evaluate any IMRT planning and delivery system combination, as well as the validity of the methodology involved

  13. Beam position optimisation for IMRT

    International Nuclear Information System (INIS)

    Holloway, L.; Hoban, P.

    2001-01-01

    Full text: The introduction of IMRT has not generally resulted in the use of optimised beam positions because to find the global solution of the problem a time consuming stochastic optimisation method must be used. Although a deterministic method may not achieve the global minimum it should achieve a superior dose distribution compared to no optimisation. This study aimed to develop and test such a method. The beam optimisation method developed relies on an iterative process to achieve the desired number of beams from a large initial number of beams. The number of beams is reduced in a 'weeding-out' process based on the total fluence which each beam delivers. The process is gradual, with only three beams removed each time (following a small number of iterations), ensuring that the reduction in beams does not dramatically affect the fluence maps of those remaining. A comparison was made between the dose distributions achieved when the beams positions were optimised in this fashion and when the beams positions were evenly distributed. The method has been shown to work quite effectively and efficiently. The Figure shows a comparison in dose distribution with optimised and non optimised beam positions for 5 beams. It can be clearly seen that there is an improvement in the dose distribution delivered to the tumour and a reduction in the dose to the critical structure with beam position optimisation. A method for beam position optimisation for use in IMRT optimisations has been developed. This method although not necessarily achieving the global minimum in beam position still achieves quite a dramatic improvement compared with no beam position optimisation and is very efficiently achieved. Copyright (2001) Australasian College of Physical Scientists and Engineers in Medicine

  14. Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E. [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Opp, Daniel; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir, E-mail: vladimir.feygelman@moffitt.org [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2014-06-15

    Purpose: In this work, the feasibility of implementing a motion-perturbation approach to accurately estimate volumetric dose in the presence of organ motion—previously demonstrated for VMAT-–is studied for static gantry IMRT. The method's accuracy is improved for the voxels that have very low planned dose but acquire appreciable dose due to motion. The study describes the modified algorithm and its experimental validation and provides an example of a clinical application. Methods: A contoured region-of-interest is propagated according to the predefined motion kernel throughout time-resolved 4D phantom dose grids. This timed series of 3D dose grids is produced by the measurement-guided dose reconstruction algorithm, based on an irradiation of a staticARCCHECK (AC) helical dosimeter array (Sun Nuclear Corp., Melbourne, FL). Each moving voxel collects dose over the dynamic simulation. The difference in dose-to-moving voxel vs dose-to-static voxel in-phantom forms the basis of a motion perturbation correction that is applied to the corresponding voxel in the patient dataset. A new method to synchronize the accelerator and dosimeter clocks, applicable to fixed-gantry IMRT, was developed. Refinements to the algorithm account for the excursion of low dose voxels into high dose regions, causing appreciable dose increase due to motion (LDVE correction). For experimental validation, four plans using TG-119 structure sets and objectives were produced using segmented IMRT direct machine parameters optimization in Pinnacle treatment planning system (v. 9.6, Philips Radiation Oncology Systems, Fitchburg, WI). All beams were delivered with the gantry angle of 0°. Each beam was delivered three times: (1) to the static AC centered on the room lasers; (2) to a static phantom containing a MAPCHECK2 (MC2) planar diode array dosimeter (Sun Nuclear); and (3) to the moving MC2 phantom. The motion trajectory was an ellipse in the IEC XY plane, with 3 and 1.5 cm axes. The period

  15. Hyperfractionated Radiotherapy and Concurrent Chemotherapy for Stage III Unascertainable Non Small Cell Lung Cancer : Preliminary Report for Response and Toxicity

    International Nuclear Information System (INIS)

    Choi, Eun Kyung; Kim, Jong Hoon; Chang, Hye Sook

    1995-01-01

    Lung cancer study group at Asan Medical Center has conducted the second prospective study to determine the efficacy and feasibility of MVP chemotherapy with concurrent hyperfractionated radiotherapy for patients with stage III unresectable non-small cell lung cancer(NSCLC). All eligible patients with stage III unresectable NSCLC were treated with hyperfractionated radiotherapy( 120 cGy/fx BID, 6480 cGY/54fx) and concurrent 2 cycles of MVP(Motomycin C 6 mg/m 2 , d2 and d29, Vinblastin 6 mg/m 2 , d2 and d29, Cisplatin 6 mg/m 2 , d1 and d28) chemotherapy. Between Aug. 1993 and Nov. 1994, 62 patients entered this study ; 6(10%) had advanced stage IIIa and 56(90%) had IIIb disease including 1 with pleural effusion and 10 with supraclavicular metastases. Among 62 Patients, 48(77%) completed planned therapy. Fourteen patients refused further treatment during chemoradiotherapy. Of 46 patients evaluable for response, 34(74%) showed major response including 10(22%) with complete and 24(52%) with partial responses. Of 48 patients evaluable for toxicity, 13(27%) showed grade IV hematologic toxicity but treatment delay did not exceed 5 days. Two patients died of sepsis during chemoradiotherapy. Server weight(more than 10%) occurred in 9 patients(19%) during treatment. Nine patients(19%) developed radiation pneumonitis. Six of these patients had grad I(mild) pneumonitis with radiographic changes within the treatment fields. Three other patients had grade II pneumonitis, but none of theses patients had continuous symptoms after steroid treatment. Concurrent chemoradiotherapy for patients with advanced NSCLC was well tolerated with acceptable toxicity and achieved higher response rates than the first study, but rather low compliance rate(7%) in this study is worrisome. We need to improve nutritional support during treatment and to use G-CSF to improve leukopenia and if necessary, supportive care will given as in patients. Longer follow-up and larger sample size is needed to

  16. Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT

    International Nuclear Information System (INIS)

    Yang, Y.; Xing, L.; Li, J.G.; Palta, J.; Chen, Y.; Luxton, Gary; Boyer, A.

    2003-01-01

    Independent verification of the MU settings and dose calculation of IMRT treatment plans is an important step in the IMRT quality assurance (QA) procedure. At present, the verification is mainly based on experimental measurements, which are time consuming and labor intensive. Although a few simplified algorithms have recently been proposed for the independent dose (or MU) calculation, head scatter has not been precisely taken into account in all these investigations and the dose validation has mainly been limited to the central axis. In this work we developed an effective computer algorithm for IMRT MU and dose validation. The technique is superior to the currently available computer-based MU check systems in that (1) it takes full consideration of the head scatter and leaf transmission effects; and (2) it allows a precise dose calculation at an arbitrary spatial point instead of merely a point on the central axis. In the algorithm the dose at an arbitrary spatial point is expressed as a summation of the contributions of primary and scatter radiation from all beamlets. Each beamlet is modulated by a dynamic modulation factor (DMF), which is determined by the MLC leaf trajectories, the head scatter, the jaw positions, and the MLC leaf transmission. A three-source model was used to calculate the head scatter distribution for irregular segments shaped by MLC and the scatter dose contributions were computed using a modified Clarkson method. The system reads in MLC leaf sequence files (or RTP files) generated by the Corvus (NOMOS Corporation, Sewickley, PA) inverse planning system and then computes the doses at the desired points. The algorithm was applied to study the dose distributions of several testing intensity modulated fields and two multifield Corvus plans and the results were compared with Corvus plans and experimental measurements. The final dose calculations at most spatial points agreed with the experimental measurements to within 3% for both the specially

  17. Fast IMRT by increasing the beam number and reducing the number of segments

    International Nuclear Information System (INIS)

    Bratengeier, Klaus; Gainey, Mark B; Flentje, Michael

    2011-01-01

    The purpose of this work is to develop fast deliverable step and shoot IMRT technique. A reduction in the number of segments should theoretically be possible, whilst simultaneously maintaining plan quality, provided that the reduction is accompanied by an increased number of gantry angles. A benefit of this method is that the segment shaping could be performed during gantry motion, thereby reducing the delivery time. The aim was to find classes of such solutions whose plan quality can compete with conventional IMRT. A planning study was performed. Step and shoot IMRT plans were created using direct machine parameter optimization (DMPO) as a reference. DMPO plans were compared to an IMRT variant having only one segment per angle ('2-Step Fast'). 2-Step Fast is based on a geometrical analysis of the topology of the planning target volume (PTV) and the organs at risk (OAR). A prostate/rectum case, spine metastasis/spinal cord, breast/lung and an artificial PTV/OAR combination of the ESTRO-Quasimodo phantom were used for the study. The composite objective value (COV), a quality score, and plan delivery time were compared. The delivery time for the DMPO reference plan and the 2-Step Fast IMRT technique was measured and calculated for two different linacs, a twelve year old Siemens Primus™ ('old' linac) and two Elekta Synergy™ 'S' linacs ('new' linacs). 2-Step Fast had comparable or better quality than the reference DMPO plan. The number of segments was smaller than for the reference plan, the number of gantry angles was between 23 and 34. For the modern linac the delivery time was always smaller than that for the reference plan. The calculated (measured) values showed a mean delivery time reduction of 21% (21%) for the new linac, and of 7% (3%) for the old linac compared to the respective DMPO reference plans. For the old linac, the data handling time per beam was the limiting factor for the treatment time reduction. 2-Step

  18. Fast IMRT by increasing the beam number and reducing the number of segments

    Directory of Open Access Journals (Sweden)

    Bratengeier Klaus

    2011-12-01

    Full Text Available Abstract Purpose The purpose of this work is to develop fast deliverable step and shoot IMRT technique. A reduction in the number of segments should theoretically be possible, whilst simultaneously maintaining plan quality, provided that the reduction is accompanied by an increased number of gantry angles. A benefit of this method is that the segment shaping could be performed during gantry motion, thereby reducing the delivery time. The aim was to find classes of such solutions whose plan quality can compete with conventional IMRT. Materials/Methods A planning study was performed. Step and shoot IMRT plans were created using direct machine parameter optimization (DMPO as a reference. DMPO plans were compared to an IMRT variant having only one segment per angle ("2-Step Fast". 2-Step Fast is based on a geometrical analysis of the topology of the planning target volume (PTV and the organs at risk (OAR. A prostate/rectum case, spine metastasis/spinal cord, breast/lung and an artificial PTV/OAR combination of the ESTRO-Quasimodo phantom were used for the study. The composite objective value (COV, a quality score, and plan delivery time were compared. The delivery time for the DMPO reference plan and the 2-Step Fast IMRT technique was measured and calculated for two different linacs, a twelve year old Siemens Primus™ ("old" linac and two Elekta Synergy™ "S" linacs ("new" linacs. Results 2-Step Fast had comparable or better quality than the reference DMPO plan. The number of segments was smaller than for the reference plan, the number of gantry angles was between 23 and 34. For the modern linac the delivery time was always smaller than that for the reference plan. The calculated (measured values showed a mean delivery time reduction of 21% (21% for the new linac, and of 7% (3% for the old linac compared to the respective DMPO reference plans. For the old linac, the data handling time per beam was the limiting factor for the treatment time

  19. IMRT optimization with pseudo-biologic objective function

    International Nuclear Information System (INIS)

    Yi, B. Y.; Ahn, S. D.; Kim, J. H.; Lee, S. W.; Choi, E. K.

    2002-01-01

    The pseudo-biologic objective function has been proposed for the IMRT optimization. It is similar to the biological objective function in mathematical shape, but uses physical parameters. The pseudo-biologic objective function concept is consisted of the target coverage index (TCI) and the organ score index (OSI), was introduced. The TCI was expressed as the sum of all of the weighted bins of target dose volume histogram (DVH). The weights were given as the normal distribution of which the average is 100 % and the standard deviation is ±. The OSI was expressed as similar way. The average of the normal distribution was 0% of the dose and that of standard deviation was selected as a function of limiting dose and its importance. The objective function could be calculated as the product of the TCI and OSI's. The RTP Tool Box (RTB) was used for this study. The constraints applied in the optimization was intuitively clinical experience based numbers, while the physical objective function asks just numbers which are not necessarily based on the clinic, and the parameters for the biologic objective functions are uncertain. The OSI's from the pseudo-biological function showed better results than from the physical functions, while TCI's showed similar tendency. We could show that the pseudo-biologic function can be used for an IMRT objective function on behalf of the biological objective function

  20. Implementation of IMRT in a real case of breast cancer radiotherapy in the 'Hospital Hermanos Ameijeiras' Service

    International Nuclear Information System (INIS)

    Rodriguez Zayas, Michael; Correa Pablos, Tamara; Perez Guevara, Adrian; Gonzalez Perez, Yelina; Sola Rodriguez, Yeline; Reyes Gonzalez, Tommy; Caballero, Roberto; Del Castillo Carrillo, Concepcion; Mena Huerta, Yailen

    2009-01-01

    Patients with left breast cancer suggest a clinical challenge because it radiates significantly heart, lung and contralateral breast with tangential beam techniques. We performed a study to: (1) design a plan using intensity modulated radiation therapy (IMRT), (2) compare IMRT plan with a plan of 3DCRT beam shear, (3) quantify the benefits of a treatment modality over another. A case diagnosed with breast cancer and treated with IMRT planned. The planning is done with the TPS Precise Plan version 2.16, with the inverse method based on openings, the treatment is carried out by way of step and shoot in the Elekta Precise Linac model with nominal energy of photons 6mV (TPR20, 10 = 0.681). (Author)