WorldWideScience

Sample records for ac line conditioners

  1. Refrigerant lines in split-type air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Rettenberger, P

    1979-01-01

    Condensator and evaporating units of split-type air conditioners are evaluated and filled with the refrigerant by the producer. The line systems are hermetically closed and prevent the loss of refrigerant and the penetration of moisture or dirt. The best installation method is the 'bendable lines'. They combine flexibility and easy installation with the advantages of the copper pipe. Several ducting systems and their connecting elements like couplings and valves are described, their installation is explained. These flexible systems are especially suitable for small air-condition plants of the split-type the evaporating unit of which is portable and can put where it is desired.

  2. Active power line conditioners design, simulation and implementation for improving power quality

    CERN Document Server

    Revuelta, Patricio Salmeron; Litrán, Salvador Pérez

    2015-01-01

    Active Power Line Conditioners: Design, Simulation and Implementation for Improving Power Quality presents a rigorous theoretical and practical approach to active power line conditioners, one of the subjects of most interest in the field of power quality. Its broad approach offers a journey that will allow power engineering professionals, researchers, and graduate students to learn more about the latest landmarks on the different APLC configurations for load active compensation. By introducing the issues and equipment needs that arise when correcting the lack of power quality in power grids

  3. Composite Based EHV AC Overhead Transmission Lines

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard

    and analysed with regard to the possibilities, limitations and risks widespread application of composite materials on EHV AC overhead transmission lines may present. To form the basis for evaluation of the useability of composite materials, dierent overhead line projects aimed at reducing the environmental...

  4. Ac irreversibility line of bismuth-based high temperature superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Mehdaoui, A. [Laboratoire de Physique et de Spectroscopie Electronique, URA 1435 Faculte des Sciences, Universite de Haute Alsace 4, rue des Freres Lumiere, 68093 Mulhouse Cedex (France); Beille, J. [Laboratoire Louis Neel, CNRS, BP 166, 38042 Grenoble Cedex 9 (France); Berling, D.; Loegel, B. [Laboratoire de Physique et de Spectroscopie Electronique, URA 1435 Faculte des Sciences, Universite de Haute Alsace 4, rue des Freres Lumiere, 68093 Mulhouse Cedex (France); Noudem, J.G.; Tournier, R. [EPM-MATFORMAG, Laboratoire dElaboration par Procede Magnetique, CNRS, BP 166, 38042 Grenoble Cedex 9 (France)

    1997-09-01

    We discuss the magnetic properties of lead doped Bi-2223 bulk samples obtained through combined magnetic melt texturing and hot pressing (MMTHP). The ac complex susceptibility measurements are achieved over a broad ac field range (1 Oe{lt}h{sub ac}{lt}100 Oe) and show highly anisotropic properties. The intergranular coupling is improved in the direction perpendicular to the applied stress and magnetic field direction, and an intragranular loss peak is observed for the first time. A comparison is made with other bismuth-based compounds and it is shown that the MMTHP process shifts the ac irreversibility line (ac IL) toward higher fields. It is also shown that all the ac IL{close_quote}s for quasi 2D bismuth-based compounds show a nearly quadratic temperature dependence and deviate therefore strongly from the linear behavior observed in quasi 3D compounds and expected from a critical state model.{copyright} {ital 1997 Materials Research Society.}

  5. Ac irreversibility line of bismuth-based high temperature superconductors

    International Nuclear Information System (INIS)

    Mehdaoui, A.; Beille, J.; Berling, D.; Loegel, B.; Noudem, J.G.; Tournier, R.

    1997-01-01

    We discuss the magnetic properties of lead doped Bi-2223 bulk samples obtained through combined magnetic melt texturing and hot pressing (MMTHP). The ac complex susceptibility measurements are achieved over a broad ac field range (1 Oe ac <100 Oe) and show highly anisotropic properties. The intergranular coupling is improved in the direction perpendicular to the applied stress and magnetic field direction, and an intragranular loss peak is observed for the first time. A comparison is made with other bismuth-based compounds and it is shown that the MMTHP process shifts the ac irreversibility line (ac IL) toward higher fields. It is also shown that all the ac IL close-quote s for quasi 2D bismuth-based compounds show a nearly quadratic temperature dependence and deviate therefore strongly from the linear behavior observed in quasi 3D compounds and expected from a critical state model.copyright 1997 Materials Research Society

  6. AC conductivity of a quantum Hall line junction

    International Nuclear Information System (INIS)

    Agarwal, Amit; Sen, Diptiman

    2009-01-01

    We present a microscopic model for calculating the AC conductivity of a finite length line junction made up of two counter- or co-propagating single mode quantum Hall edges with possibly different filling fractions. The effect of density-density interactions and a local tunneling conductance (σ) between the two edges is considered. Assuming that σ is independent of the frequency ω, we derive expressions for the AC conductivity as a function of ω, the length of the line junction and other parameters of the system. We reproduce the results of Sen and Agarwal (2008 Phys. Rev. B 78 085430) in the DC limit (ω→0), and generalize those results for an interacting system. As a function of ω, the AC conductivity shows significant oscillations if σ is small; the oscillations become less prominent as σ increases. A renormalization group analysis shows that the system may be in a metallic or an insulating phase depending on the strength of the interactions. We discuss the experimental implications of this for the behavior of the AC conductivity at low temperatures.

  7. Cytotoxicity test of 40, 50 and 60% citric acid as dentin conditioner by using MTT assay on culture cell line

    Directory of Open Access Journals (Sweden)

    Christian Khoswanto

    2008-09-01

    Full Text Available Background: Open dentin is always covered by smear layer, therefore before restoration is performed, cavity or tooth which has been prepared should be clean from dirt. The researchers suggested that clean dentin surface would reach effective adhesion between resin and tooth structure, therefore dentin conditioner like citric acid was used to reach the condition. Even though citric acid is not strong acid but it can be very erosive to oral mucous. Several requirements should be fulfilled for dental product such as non toxic, non irritant, biocompatible and should not have negative effect against local, systemic or biological environment. Cytotoxicity test was apart of biomaterial evaluation and needed for standard screening. Purpose: This study was to know the cytotoxicity of 40, 50, 60% citric acid as dentin conditioner using MTT assay. Method: This study is an experimental research using the Post-Test Only Control Group Design. Six samples of each 40, 50 and 60% citric acid for citotoxicity test using MTT assay. The density of optic formazan indicated the number of living cells. All data were statistically analyzed by one way ANOVA. Result: The percentage of living cells in 40, 50 and 60% citric acid were 95.14%, 93.42% and 93.14%. Conclusion: Citric acid is non toxic and safe to be used as dentine conditioner.

  8. Air conditioner

    International Nuclear Information System (INIS)

    Sato, Masaaki

    1993-01-01

    The present invention provides an air conditioner which can prevent an undesirable effects on a human body due to radon daughter nuclides in a closed space. That is, the concentration of the radon daughter nuclides in the air in the closed space is continuously measured. A necessary amount of ventilation air is determined based on the measured concentration to generate control signals. External air is introduced into the closed space by the generated control signals. With such procedures, necessary amount of external air is taken from the atmospheric air which can be regarded to have the radon daughter nuclide concentration substantially at zero, thereby enabling to reduce the concentration of the radon daughter nuclides in the closed space. As a result, undesired effects on the human body due to the radon daughter nuclides staying in the closed space can be prevented. According to simulation, the radon daughter nuclides are rapidly decreased only by ventilation only for three times or so in one hour. Accordingly, ventilation is extremely effective and convenient means as a countermeasure for the radon daughter nuclides. (I.S.)

  9. WATER QUALITY AND TREATMENT CONSIDERATIONS FOR CEMENT-LINED AND A-C PIPE

    Science.gov (United States)

    Both cement mortar lined (CML) and asbestos-cement pipes (A-C) are widely used in many water systems. Cement linings are also commonly applied in-situ after pipe cleaning, usually to prevent the recurrence of red water or tuberculation problems. Unfortunately, little consideratio...

  10. Efficiency estimation method of three-wired AC to DC line transfer

    Science.gov (United States)

    Solovev, S. V.; Bardanov, A. I.

    2018-05-01

    The development of power semiconductor converters technology expands the scope of their application to medium voltage distribution networks (6-35 kV). Particularly rectifiers and inverters of appropriate power capacity complement the topology of such voltage level networks with the DC links and lines. The article presents a coefficient that allows taking into account the increase of transmission line capacity depending on the parameters of it. The application of the coefficient is presented by the example of transfer three-wired AC line to DC in various methods. Dependences of the change in the capacity from the load power factor of the line and the reactive component of the resistance of the transmission line are obtained. Conclusions are drawn about the most efficient ways of converting a three-wired AC line to direct current.

  11. Mold contamination of automobile air conditioner systems.

    Science.gov (United States)

    Kumar, P; Lopez, M; Fan, W; Cambre, K; Elston, R C

    1990-02-01

    Eight cars belonging to patients who were found to have exacerbation of allergic rhinitis and bronchial asthma after turning on the air conditioner in their cars were examined. Mold concentrations inside the passenger compartment with the a/c turned off and at different climate control settings were lower than concentrations in the outside air. After turning on the air conditioner to "Max", cultures obtained at various intervals revealed that mold concentrations decreased significantly with time. Furthermore, placement of a filter at the portal of entry of outside air significantly reduced the mold concentration in the passenger compartment.

  12. Photovoltaic array: Power conditioner interface characteristics

    Science.gov (United States)

    Gonzalez, C. C.; Hill, G. M.; Ross, R. G., Jr.

    1982-01-01

    The electrical output (power, current, and voltage) of flat plate solar arrays changes constantly, due primarily to changes in cell temperature and irradiance level. As a result, array loads such as dc-to-ac power conditioners must be capable of accommodating widely varying input levels while maintaining operation at or near the maximum power point of the array. The array operating characteristics and extreme output limits necessary for the systematic design of array load interfaces under a wide variety of climatic conditions are studied. A number of interface parameters are examined, including optimum operating voltage, voltage energy, maximum power and current limits, and maximum open circuit voltage. The effect of array degradation and I-V curve fill factor or the array power conditioner interface is also discussed. Results are presented as normalized ratios of power conditioner parameters to array parameters, making the results universally applicable to a wide variety of system sizes, sites, and operating modes.

  13. Corona Onset Characteristics of Bundle Conductors in UHV AC Power Lines at 2200 m Altitude

    Directory of Open Access Journals (Sweden)

    Shilong Huang

    2018-04-01

    Full Text Available The corona onset characteristic of bundle conductors is an important limiting factor for the design of UHV AC power lines in high-altitude areas. An experimental study on the corona characteristics of 8 × LGJ630, 6 × LGJ720, 8 × LGJ720 and 10 × LGJ720 bundle conductors commonly used in UHV power lines under dry and wet conductor conditions, as well as artificial moderate and heavy rain conditions, was conducted in Ping’an County, Xining City (elevation 2200 m. By using the tangent line method, the corona onset voltages and onset electric field of four types of conductors at high altitudes are obtained for the first time. In addition, the calculation model of corona onset voltage considering the outer strands’ effect on the electric field and the geometric factor in the corona cage in high altitude areas is established. The comparison of the calculation results and experimental results under dry conditions verifies the model’s correctness. Based on the results, an optimal selection scheme for high altitudes is proposed. The roughness coefficient was also calculated and analysed: the roughness coefficient of bundled conductors was between 0.59 and 0.77, and the roughness coefficient of the wet conductor was between the dry and rainy conditions. Both the experimental data and the calculation model can provide a reference for conductor selection for UHV AC power lines for use in high-altitude areas.

  14. Adapting AC Lines to DC Grids for Large-Scale Renewable Power Transmission

    Directory of Open Access Journals (Sweden)

    D. Marene Larruskain

    2014-10-01

    Full Text Available All over the world, governments of different countries are nowadays promoting the use of clean energies in order to achieve sustainable energy systems. In this scenario, since the installed capacity is continuously increasing, renewable sources can play an important role. Notwithstanding that, some important problems may appear when connecting these sources to the grid, being the overload of distribution lines one of the most relevant. In fact, renewable generation is usually connected to the nearest AC grid, although this HV system may not have been designed considering distributed generation. In the particular case of large wind farms, the electrical grid has to transmit all the power generated by wind energy and, as a consequence, the AC system may get overloaded. It is therefore necessary to determine the impact of wind power transmission so that appropriate measures can be taken. Not only are these measures influenced by the amount of power transmitted, but also by the quality of the transmitted power, due to the output voltage fluctuation caused by the highly variable nature of wind. When designing a power grid, although AC systems are usually the most economical solution because of its highly proven technology, HVDC may arise in some cases (e.g. offshore wind farms as an interesting alternative, offering some added values such as lower losses and better controllability. This way, HVDC technology can solve most of the aforementioned problems and has a good potential for future use. Additionally, the fast development of power electronics based on new and powerful semiconductor devices allow the spread of innovative technologies, such as VSC-HVDC, which can be applied to create DC grids. This paper focuses on the main aspects involved in adapting the existing overhead AC lines to DC grids, with the objective of improving the transmission of distributed renewable energy to the centers of consumption.

  15. Air Conditioner/Dehumidifier

    Science.gov (United States)

    1986-01-01

    An ordinary air conditioner in a very humid environment must overcool the room air, then reheat it. Mr. Dinh, a former STAC associate, devised a heat pipe based humidifier under a NASA Contract. The system used heat pipes to precool the air; the air conditioner's cooling coil removes heat and humidity, then the heat pipes restore the overcooled air to a comfortable temperature. The heat pipes use no energy, and typical savings are from 15-20%. The Dinh Company also manufactures a "Z" coil, a retrofit cooling coil which may be installed on an existing heater/air conditioner. It will also provide free hot water. The company has also developed a photovoltaic air conditioner and solar powered water pump.

  16. Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Woods, J.; Judkoff, R.

    2012-04-01

    This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

  17. Ultrahigh-rate supercapacitors based on eletrochemically reduced graphene oxide for ac line-filtering

    Science.gov (United States)

    Sheng, Kaixuan; Sun, Yiqing; Li, Chun; Yuan, Wenjing; Shi, Gaoquan

    2012-02-01

    The recent boom in multifunction portable electronic equipments requires the development of compact and miniaturized electronic circuits with high efficiencies, low costs and long lasting time. For the operation of most line-powered electronics, alternating current (ac) line-filters are used to attenuate the leftover ac ripples on direct current (dc) voltage busses. Today, aluminum electrolytic capacitors (AECs) are widely applied for this purpose. However, they are usually the largest components in electronic circuits. Replacing AECs by more compact capacitors will have an immense impact on future electronic devices. Here, we report a double-layer capacitor based on three-dimensional (3D) interpenetrating graphene electrodes fabricated by electrochemical reduction of graphene oxide (ErGO-DLC). At 120-hertz, the ErGO-DLC exhibited a phase angle of -84 degrees, a specific capacitance of 283 microfaradays per centimeter square and a resistor-capacitor (RC) time constant of 1.35 milliseconds, making it capable of replacing AECs for the application of 120-hertz filtering.

  18. Cardio-Muscular Conditioner

    Science.gov (United States)

    1993-01-01

    In the mid-sixties, Gary Graham, a Boeing designer, developed a cardiovascular conditioner for a planned Air Force orbiting laboratory. After the project was cancelled, Graham participated in space station conditioning studies for the Skylab program. Twenty years later, he used this expertise to develop the Shuttle 2000-1, a physical therapy and athletic development conditioner, available through Contemporary Designs. The machine is used by football teams, sports clinics and medical rehabilitation centers. Cardiovascular fitness and muscular strength development are promoted through both kinetic and plyometric exercises.

  19. Pulmonary function tests in air conditioner users | Vidya ...

    African Journals Online (AJOL)

    Background: Modernization has been implicated in the pathogenesis of allergic airway diseases. House dust, mites, and indoor air pollutants have been reported to cause elevation of serum IgE levels and/or enhancement of eosinophil activity. A component of modern lifestyle is the intense use of air-conditioners (AC) that ...

  20. Pulmonary functions in air conditioner users.

    Science.gov (United States)

    Khaliq, Farah; Sharma, Sameer; Tandon, O P

    2006-01-01

    Air conditioning may affect human health since it has profound effect on our environment, than just lowering temperature. The present study was planned to assess the effect of air conditioners (AC) on pulmonary functions in young healthy non-smoker males. The study group comprised of ten subjects who were using AC's in their cars for at least 1 hr daily since last 6 months. While ten subjects who did not use AC at all served as controls. The pulmonary functions were assessed using PK Morgan 232 spirometer in a closed room. The peak expiratory flow rate (PEFR) and Forced expiratory flow between 25-75% of vital capacity (FEF25-75) were significantly reduced in subjects using car AC's. Inspiratory flow rates also showed a trend towards decline in AC users but could not reach the level of significance. The lung volumes and capacities were not significantly different in the two groups except for forced expiratory volume in 0.5 sec (FEV 0.5 sec), which also decreased in AC users. The airway resistance and lung compliance did not show significant change. In the presence of normal FEV1, reduced FEF25-75% which is the flow rate over the middle half of vital capacity, is an evidence of mild airflow limitation. The result is suggestive of predisposition of AC users towards respiratory disorders in form of mild airflow restriction.

  1. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators

    Directory of Open Access Journals (Sweden)

    Dotsinsky Ivan

    2005-11-01

    Full Text Available Abstract Background Public access defibrillators (PADs are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Method Moving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed. This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling. Results The proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection. Conclusion The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression.

  2. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators.

    Science.gov (United States)

    Dotsinsky, Ivan

    2005-11-26

    Public access defibrillators (PADs) are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Moving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed). This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC) for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling. The proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection. The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression.

  3. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  4. High Efficiency Room Air Conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, Pradeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

  5. UPQC (Unified power Quality Conditioner)

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. UPQC (Unified power Quality Conditioner). Hybrid of Shunt and Series compensator. Compensate both Current Quality and Voltage Quality. Costlier Solution as it involves two set of Inverters.

  6. Micromorphology of pelletized soil conditioners

    Science.gov (United States)

    Hirsch, Florian; Dietrich, Nils; Knoop, Christine; Raab, Thomas

    2017-04-01

    Soil conditioners produced by anaerobic digestion and subsequent composting of organic household waste, bear the potential to improve unproductive farmland together with a reduced input risk of unwanted pollutants into the soils. Within the VeNGA project (http://www.biogas-network.de/venga), soil conditioners from anaerobically digested organic household waste are tested for their potential to increase plant growth in glasshouse and field experiments. Because the production techniques of these soil conditioners may influence their physical and chemical behaviour in the soil, two different techniques for pelletizing the soil conditioners where applied. We present findings from a pot experiment with cereal that has been sampled after two months for micromorphological analyses. We visualize the decomposition and the physical behaviour of the soil conditioners. Pellets produced in an agglomeration mixer result in dense balls, that are only slightly decomposed after the trial. But the soil conditioners created under pressure in a screw extruder are rich in voids and have the potential of retaining more soil water.

  7. Cry1Ac Protein expression in tissues of potato (solanumtuberosum spp. andigena) transgenic lines var. Diacol Capiro

    International Nuclear Information System (INIS)

    Vanegas Araujo, Pablo Andres; Blanco Martinez, Jennifer Teresa; Chaparro Giraldo, Alejandro

    2010-01-01

    The potato plant is the fourth most important crop in the world. In Colombia around 2.8 million tons are produced annually economically supporting 90000 families. In the country, the major economic impact in the crop is caused by Tecia solanivora that originates loses up to 100% in the tuber production. The genetic plant breeding related to the introduction of Cry genes which codify insecticidal crystal proteins is an alternative for reducing the insect attack in commercial crops. In this work, the insertion, transcription and expression of Cry1Ac gen was characterized in different tissues and three development stages of two transgenic lines of Solanum tuberosum variety Diacol Capiro that were previously transformed by Agrobacterium tumefaciens method. The characterization was realized by PCR, RT-PCR and ELISA techniques. The gen insertion and transcription was confirmed using primers for Cry1Ac gen that amplified a specific band of 766 bp. The protein expression levels were higher than 45 µg/g and were not significantly different between the analyzed lines or the three development stages. Furthermore, taking into account some relevant phenotypic features, no significant differences were found between transgenic lines and controls. The results suggest that monitoring and biosecurity assays are necessary with this vegetal material because their high level expression inside all the tissues analyzed that could affect non-targeted insects.

  8. Development of 2.8 V Ketjen black supercapacitors with high rate capabilities for AC line filtering

    Science.gov (United States)

    Yoo, Yongju; Park, Jinwoo; Kim, Min-Seop; Kim, Woong

    2017-08-01

    Supercapacitors are generally more compact than conventional bulky aluminum electrolytic capacitors (AECs). Replacement of AECs with supercapacitors can lead to miniaturization of electronic devices. However, even state-of-the-art supercapacitors developed in laboratories are superior to or competitive with AECs only in low voltage applications (<∼40 V). In order to improve the voltage limits of current supercapacitors, we have incorporated Ketjen black (KB) as an electrode material. Utilizing the open pore structure and the graphitic nature of KB, we demonstrate that the voltage limit can be extended to 53 V. The KB supercapacitor exhibits excellent areal capacitance, cell voltage, and phase angle values of ∼574 μF cm-2, 2.8 V, and ∼-80°, respectively. In addition, we demonstrate that an AC line filtering circuit with three supercapacitors connected in series can extend the application voltage without significant sacrifice in rate capability (ϕ ∼ -77° at 120 Hz). On the other hand, KBs are much less expensive than carbon materials previously demonstrated for AC line filtering and hence are very attractive for practical applications. We believe that this demonstration of high-performance supercapacitors made from low-cost carbon materials is both scientifically interesting and important for practical applications.

  9. Experimental Analysis on Solar Desiccant Air Conditioner

    OpenAIRE

    Dr. U. V. Kongre, C. M. Singh, A. B. Biswas

    2014-01-01

    The experiment investigated and evaluated the feasibility of an solar desiccant air conditioner. Its effectiveness as a possible air conditioner option used in household air conditioner or as an energy efficient and environmentally friendly alternative to conventional air conditioning units used in houses are evaluated. A solar water heater was used as heat gain. The model utilizes the technology of solar air conditioner system. The purpose in the long term wou...

  10. Power conditioner without isolation transformer; Toransuresu power conditioner no shohin kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Okado, C; Itami, T; Kimoto, K [Toshiba Corp., Tokyo (Japan)

    1996-10-27

    A light-weight downsized and high efficiency transformer-less type 4 kW power conditioner (inverter) has been developed. This power conditioner insures the system interconnection protection by monitoring the voltage of two single-phase three-line circuits. The power conditioner has weight of 17.5 kg and efficiency of 94%. Potential fluctuation of photovoltaic cells due to the switching of power devices at the inverter was reduced. Output capacity was reduced in the low input voltage range. Outflow of DC component was prevented in high accuracy by usually correcting the zero point drift of detector, and by using the current detector with excellent linearity. To detect the DC ground fault, and to trip the output side breaker locating at the ground fault current pass, a zero phase converter detection circuit has been developed, by which the DC component can be detected at the DC input side. As a result of performance verification, the efficiency, power factor, EMI level, protection of outflow of DC component, protection of ground fault, protection of single operation detection, and noise level were satisfied. This system is prospective for the diffusion of photovoltaic power generation in the future. 3 refs., 8 figs., 1 tab.

  11. Harmonic content in the variable-frequency ac power line of TFTR

    International Nuclear Information System (INIS)

    Zabar, Z.; Bronner, G.; McMurray, S.; Karady, G.

    1979-12-01

    Studies were made of the harmonic content of the current and voltage at the generator bus of the Tokamak Fusion Test Reactor. Out of numerous load scenarios, one case was considered in detail. The harmonics were found acceptable for the generator; however, control problems and substantial telecommunications interference may result, requiring appropriate control measures and shielded telecommunication lines

  12. Towards a Residential Air-Conditioner Usage Model for Australia

    Directory of Open Access Journals (Sweden)

    Mark Goldsworthy

    2017-08-01

    Full Text Available Realistic models of occupant behaviour in relation to air-conditioner (a/c use are fundamentally important for developing accurate building energy simulation tools. In Australia and elsewhere, such simulation tools are inextricably bound both in legislation and in the design of new technology, electricity infrastructure and regulatory schemes. An increasing number of studies in the literature confirm just how important occupants are in determining overall energy consumption, but obtaining the data on which to build behaviour models is a non-trivial task. Here data is presented on air-conditioner usage derived from three different types of case study analyses. These are: (i use of aggregate energy consumption data coupled with weather, demographic and building statistics across Australia to estimate key predictors of energy use at the aggregate level; (ii use of survey data to determine characteristic a/c switch on/off behaviours and usage frequencies; and (iii use of detailed household level sub-circuit monitoring from 140 households to determine a/c switch on/off probabilities and their dependence on different building and occupant parameters. These case studies are used to assess the difficulties associated with translation of different forms of individual, aggregate and survey based information into a/c behaviour simulation models. Finally a method of linking the data gathering methodologies with the model development is suggested. This method would combine whole-of-house “smart”-meter data measurements with linked targeted occupant surveying.

  13. Triple Line-Voltage Cascaded VIENNA Converter Applied as the Medium-Voltage AC Drive

    Directory of Open Access Journals (Sweden)

    Jia Zou

    2018-04-01

    Full Text Available A novel rectifier based on a triple line-voltage cascaded VIENNA converter (LVC-VC was proposed. Compared to the conventional cascaded H-bridge converters, the switch voltage stress is lower, and the numbers of switches and dc capacitors are fewer under similar operating conditions in the proposed new multilevel converter. The modeling and control for the LVC-VC ware presented. Based on the analysis of the operation principle of the new converter, the power factor correction of the proposed converter was realized by employing a traditional one-cycle control strategy. The minimum average value and maximum harmonic components of the dc-link voltages of the three VIENNA rectifier modules ware calculated. Three VIENNA dc-link voltages were unbalanced under the unbalanced load conditions, so the zero sequence current was injected to the three inner currents for balancing three VIENNA dc-link voltages. Simulation and the results of the experiment verified the availability of the new proposed multilevel converter and the effectiveness of the corresponding control strategy applied.

  14. Shuttle APS propellant thermal conditioner study

    Science.gov (United States)

    Pearson, W. E.

    1971-01-01

    A study program was performed to allow selection of thermal conditioner assemblies for superheating O2 and H2 at supercritical pressures. The application was the auxiliary propulsion system (APS) for the space shuttle vehicle. The O2/H2 APS propellant feed system included propellant conditioners, of which the thermal conditioner assemblies were a part. Cryogens, pumped to pressures above critical, were directed to the thermal conditioner assembly included: (1) a gas generator assembly with ignition system and bipropellant valves, which burned superheated O2 and H2 at rich conditions; (2) a heat exchanger assembly for thermal conditioning of the cryogenic propellant; and (3) a dump nozzle for heat exchanger exhaust.

  15. MOEA based design of decentralized controllers for LFC of interconnected power systems with nonlinearities, AC-DC parallel tie-lines and SMES units

    International Nuclear Information System (INIS)

    Ganapathy, S.; Velusami, S.

    2010-01-01

    A new design of Multi-Objective Evolutionary Algorithm based decentralized controllers for load-frequency control of interconnected power systems with Governor Dead Band and Generation Rate Constraint nonlinearities, AC-DC parallel tie-lines and Superconducting Magnetic Energy Storage (SMES) units, is proposed in this paper. The HVDC link is used as system interconnection in parallel with AC tie-line to effectively damp the frequency oscillations of AC system while the SMES unit provides bulk energy storage and release, thereby achieving combined benefits. The proposed controller satisfies two main objectives, namely, minimum Integral Squared Error of the system output and maximum closed-loop stability of the system. Simulation studies are conducted on a two area interconnected power system with nonlinearities, AC-DC tie-lines and SMES units. Results indicate that the proposed controller improves the transient responses and guarantees the closed-loop stability of the overall system even in the presence of system nonlinearities and with parameter changes.

  16. Conventional P-ω/Q-V Droop Control in Highly Resistive Line of Low-Voltage Converter-Based AC Microgrid

    DEFF Research Database (Denmark)

    Hou, Xiaochao; Sun, Yao; Yuan, Wenbin

    2016-01-01

    -ω/Q-V droop control is adopted in the low-voltage AC microgrid. As a result, the active power sharing among the distributed generators (DGs) is easily obtained without communication. More importantly, this study clears up the previous misunderstanding that conventional P-ω/Q-V droop control is only applicable...... to microgrids with highly inductive lines, and lays a foundation for the application of conventional droop control under different line impedances. Moreover, in order to guarantee the accurate reactive power sharing, a guide for designing Q-V droop gains is given, and virtual resistance is adopted to shape......In low-voltage converter-based alternating current (AC) microgrids with resistive distribution lines, the P-V droop with Q-f boost (VPD/FQB) is the most common method for load sharing. However, it cannot achieve the active power sharing proportionally. To overcome this drawback, the conventional P...

  17. Power system stabilization by SMES using current-fed pwm power conditioner

    International Nuclear Information System (INIS)

    Ishikawa, T.; Akita, S.; Taniguchi, H.; Kosho, S.; Tanaka, T.

    1988-01-01

    A superconducting magnetic energy storage (SMES) unit, consisted of superconducting coil and AC/DC power conditioner, can be used to suppress various kinds of instability that may cause service interruption in electric power system as it has high controllability of input/output electric power. Power system stabilizing ability of SMES has been examined experimentally by using model power system and small SMES unit. Current-fed PWM power conditioner was used to obtain maximum stabilizing effect by controlling active and reactive power simultaneously and independently. Power conditioner configuration, operating characteristics and control scheme for power system stabilization are also described. Results from experiments show the effectiveness of SMES on power system stabilization

  18. Substantial energy conservation in air conditioners; Substantiele energiebesparing bij luchtbehandelingsinstallaties

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    An air conditioner has been retrofitted by application of an optimized fan in combination with an EC motor (brushless dc-motor). Attention is paid to the difference between an AC- and and EC motor, between free-running and spiral housing fans, between direct or indirect-driven, and between forward-bended and backward-bended blades. By means of equations and diagrams the realized energy conservation is visualized. [Dutch] De renovatie van een luchtbehandelingskast wordt besproken. Door de toepassing van ventilatoren met een geoptimaliseerde waaier in combinatie met een EC-motor (borstelloze gelijkstroommotor) wordt een substantiele energiebesparing gerealiseerd. Er wordt op verschillende aspecten ingegaan. Onder meer het verschil tussen een AC- en EC-motor, tussen vrijlopende en slakkenhuisventilatoren, tussen direct- of indirect-gedreven schoepen en tussen voorwaarts- of achterwaartsgebogen schoepen. Aan de hand van vergelijkingen en diagrammen wordt de energiewinst zichtbaar gemaakt.

  19. Conditioner for a helically transported electron beam

    International Nuclear Information System (INIS)

    Wang, Changbiao.

    1992-05-01

    The kinetic theory is developed to investigate a conditioner for a helically transported electron beam. Linear expressions for axial velocity spread are derived. Numerical simulation is used to check the theoretical results and examine nonlinear aspects of the conditioning process. The results show that in the linear regime the action of the beam conditioner on a pulsed beam mainly depends on the phase at which the beam enters the conditioner and depends only slightly on the operating wavelength. In the nonlinear regime, however, the action of the conditioner strongly depends on the operating wavelength and only slightly upon the entrance phase. For a properly chosen operating wavelength, a little less than the electron's relativistic cyclotron wavelength, the conditioner can decrease the axial velocity spread of a pulsed beam down to less than one-third of its initial value

  20. Conditioner for a helically transported electron beam

    International Nuclear Information System (INIS)

    Wang, C.

    1992-05-01

    The kinetic theory is developed to investigate a conditioner for a helically imported electron beam. Linear expressions for axial velocity spread are derived. Numerical simulation is used to check the theoretical results and examine nonlinear aspects of the conditioning process. The results show that in the linear regime the action of the beam conditioner on a pulsed beam mainly depends on the phase at which the beam enters the conditioner and depends only slightly on the operating wavelength. In the nonlinear regime, however, the action of the conditioner strongly depends on the operating wavelength and only slightly upon the entrance phase. For a properly chosen operating wavelength, a little less than the electron's relativistic cyclotron wavelength, the conditioner can decrease the axial velocity spread of a pulsed beam down to less than one-third of its initial value

  1. Space shuttle aps propellant thermal conditioner study

    Science.gov (United States)

    Fulton, D. L.

    1973-01-01

    An analytical and experimental effort was completed to evaluate a baffle type thermal conditioner for superheating O2 and H2 at supercritical pressures. The thermal conditioner consisted of a heat exchanger and an integral reactor (gas generator) operating on O2/H2 propellants. Primary emphasis was placed on the hydrogen conditioner with some effort on the oxygen conditioner and a study completed of alternate concepts for use in conditioning oxygen. A hydrogen conditioner was hot fire tested under a range of conditions to establish ignition, heat exchange and response parameters. A parallel technology task was completed to further evaluate the integral reactor and heat exchanger with the side mounted electrical spark igniter.

  2. Bifurcated SEN with Fluid Flow Conditioners

    Directory of Open Access Journals (Sweden)

    F. Rivera-Perez

    2014-01-01

    Full Text Available This work evaluates the performance of a novel design for a bifurcated submerged entry nozzle (SEN used for the continuous casting of steel slabs. The proposed design incorporates fluid flow conditioners attached on SEN external wall. The fluid flow conditioners impose a pseudosymmetric pattern in the upper zone of the mold by inhibiting the fluid exchange between the zones created by conditioners. The performance of the SEN with fluid flow conditioners is analyzed through numerical simulations using the CFD technique. Numerical results were validated by means of physical simulations conducted on a scaled cold water model. Numerical and physical simulations confirmed that the performance of the proposed SEN is superior to a traditional one. Fluid flow conditioners reduce the liquid free surface fluctuations and minimize the occurrence of vortexes at the free surface.

  3. Deaths Due to Accidental Air Conditioner Compressor Explosion: A Case Series.

    Science.gov (United States)

    Behera, Chittaranjan; Bodwal, Jatin; Sikary, Asit K; Chauhan, Mohit Singh; Bijarnia, Manjul

    2017-01-01

    In an air-conditioning system, the compressor is a large electric pump that pressurizes the refrigerant gas as part of the process of turning it back into a liquid. The explosion of an air conditioner (AC) compressor is an uncommon event, and immediate death resulted from the blast effect is not reported in forensic literature. We report three such cases in which young AC mechanics were killed on the spot due to compressor blast, while repairing the domestic split AC unit. The autopsy findings, the circumstances leading to the explosion of the compressor, are discussed in this study. © 2016 American Academy of Forensic Sciences.

  4. Conventional P-ω/Q-V Droop Control in Highly Resistive Line of Low-Voltage Converter-Based AC Microgrid

    Directory of Open Access Journals (Sweden)

    Xiaochao Hou

    2016-11-01

    Full Text Available In low-voltage converter-based alternating current (AC microgrids with resistive distribution lines, the P-V droop with Q-f boost (VPD/FQB is the most common method for load sharing. However, it cannot achieve the active power sharing proportionally. To overcome this drawback, the conventional P-ω/Q-V droop control is adopted in the low-voltage AC microgrid. As a result, the active power sharing among the distributed generators (DGs is easily obtained without communication. More importantly, this study clears up the previous misunderstanding that conventional P-ω/Q-V droop control is only applicable to microgrids with highly inductive lines, and lays a foundation for the application of conventional droop control under different line impedances. Moreover, in order to guarantee the accurate reactive power sharing, a guide for designing Q-V droop gains is given, and virtual resistance is adopted to shape the desired output impedance. Finally, the effects of power sharing and transient response are verified through simulations and experiments in converter-based AC Microgrid.

  5. ENERGY STAR Certified Room Air Conditioners

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Room Air Conditioners that are effective as of...

  6. Energy performance and consumption for biogas heat pump air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhenjun [Architectural Engineering College, Qingdao Agricultural University, 266109 (China); Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China); Wu, Huaizhi; Wu, Meiling [Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China)

    2010-12-15

    Biogas engine-driven heat pump air conditioner is a new-style system which includes biogas engine-driven heat pump, primary heat exchanger, second heat exchanger, sprayed room and fans, pumps, etc. In summertime, the air can be reheated by the waste heat water from the biogas engine in the system, while the air can be reheated and humidified by the waste heat water in winter. Reducing or displacing electrical heating requirements can achieve the great opportunity for significant energy savings. This paper, therefore, aims to improve the energy performance of the AC system by using the waste heat from the biogas engine. The mathematic model was used to research the BHPAC. Explicitly, we investigated the influence of various factors including the outdoor air temperature and humidity in summer and winter. Results show that the biogas engine-driven heat pump air conditioner can save more energy than the electrical power heat pump. In summer, the minimum for percentage of primary energy saving for BHPAC is over 25%. With the outdoor air dry-bulb temperature and the relative humidity rises, the saving energy percentage rises. In winter, the minimum for percentage of primary energy saving for BHPAC is 37%. The more the outdoor air relative humidity of the outdoor air decreases, the more the BHPAC saves energy. It is proved that the system which is a highly actively fully utilizing energy technology has good partial load characteristic and good effects of energy saving. (author)

  7. ACAC Converters for UPS

    Directory of Open Access Journals (Sweden)

    Rusalin Lucian R. Păun

    2008-05-01

    Full Text Available This paper propose a new control technique forsingle – phase ACAC converters used for a on-line UPSwith a good dynamic response, a reduced-partscomponents, a good output characteristic, a good powerfactorcorrection(PFC. This converter no needs anisolation transformer. A power factor correction rectifierand an inverter with the proposed control scheme has beendesigned and simulated using Caspoc2007, validating theconcept.

  8. A hybrid air conditioner driven by a hybrid solar collector

    Science.gov (United States)

    Al-Alili, Ali

    The objective of this thesis is to search for an efficient way of utilizing solar energy in air conditioning applications. The current solar Air Conditioners (A/C)s suffer from low Coefficient of Performance (COP) and performance degradation in hot and humid climates. By investigating the possible ways of utilizing solar energy in air conditioning applications, the bottlenecks in these approaches were identified. That resulted in proposing a novel system whose subsystem synergy led to a COP higher than unity. The proposed system was found to maintain indoor comfort at a higher COP compared to the most common solar A/Cs, especially under very hot and humid climate conditions. The novelty of the proposed A/C is to use a concentrating photovoltaic/thermal collector, which outputs thermal and electrical energy simultaneously, to drive a hybrid A/C. The performance of the hybrid A/C, which consists of a desiccant wheel, an enthalpy wheel, and a vapor compression cycle (VCC), was investigated experimentally. This work also explored the use of a new type of desiccant material, which can be regenerated with a low temperature heat source. The experimental results showed that the hybrid A/C is more effective than the standalone VCC in maintaining the indoor conditions within the comfort zone. Using the experimental data, the COP of the hybrid A/C driven by a hybrid solar collector was found to be at least double that of the current solar A/Cs. The innovative integration of its subsystems allows each subsystem to do what it can do best. That leads to lower energy consumption which helps reduce the peak electrical loads on electric utilities and reduces the consumer operating cost since less energy is purchased during the on peak periods and less solar collector area is needed. In order for the proposed A/C to become a real alternative to conventional systems, its performance and total cost were optimized using the experimentally validated model. The results showed that for an

  9. Modeling of HVDC System to Improve Estimation of Transient DC Current and Voltages for AC Line-to-Ground Fault—An Actual Case Study in Korea

    Directory of Open Access Journals (Sweden)

    Dohoon Kwon

    2017-10-01

    Full Text Available A new modeling method for high voltage direct current (HVDC systems and associated controllers is presented for the power system simulator for engineering (PSS/E simulation environment. The aim is to improve the estimation of the transient DC voltage and current in the event of an AC line-to-ground fault. The proposed method consists primary of three interconnected modules for (a equation conversion; (b control-mode selection; and (c DC-line modeling. Simulation case studies were carried out using PSS/E and a power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC model of the Jeju– Haenam HVDC system in Korea. The simulation results are compared with actual operational data and the PSCAD/EMTDC simulation results for an HVDC system during single-phase and three-phase line-to-ground faults, respectively. These comparisons show that the proposed PSS/E modeling method results in the improved estimation of the dynamic variation in the DC voltage and current in the event of an AC network fault, with significant gains in computational efficiency, making it suitable for real-time analysis of HVDC systems.

  10. Accelerating Energy Efficiency Improvements in Room Air Conditioners in India: Potential, Costs-Benefits, and Policies

    OpenAIRE

    Abhyankar, N; Shah, N; Park, WY; Phadke, AA

    2017-01-01

    Rising incomes, increasing urbanization, and large cooling demand prompted by India’s hot, humid climate are driving increasing uptake of room air conditioners (ACs). Air conditioning already accounts for 40-60% of summer peak load in large Indian cities such as Delhi and is on track to contribute 140 gigawatts (GW) ( 30%) to peak demand in 2030. India’s standards and labeling policies improved the market average efficiency of room ACs by about 35% between 2006 and 2016 (3% per year) even as ...

  11. Application of the parametric proper generalized decomposition to the frequency-dependent calculation of the impedance of an AC line with rectangular conductors

    Directory of Open Access Journals (Sweden)

    Sancarlos-González Abel

    2017-12-01

    Full Text Available AC lines of industrial busbar systems are usually built using conductors with rectangular cross sections, where each phase can have several parallel conductors to carry high currents. The current density in a rectangular conductor, under sinusoidal conditions, is not uniform. It depends on the frequency, on the conductor shape, and on the distance between conductors, due to the skin effect and to proximity effects. Contrary to circular conductors, there are not closed analytical formulas for obtaining the frequency-dependent impedance of conductors with rectangular cross-section. It is necessary to resort to numerical simulations to obtain the resistance and the inductance of the phases, one for each desired frequency and also for each distance between the phases’ conductors. On the contrary, the use of the parametric proper generalized decomposition (PGD allows to obtain the frequency-dependent impedance of an AC line for a wide range of frequencies and distances between the phases’ conductors by solving a single simulation in a 4D domain (spatial coordinates x and y, the frequency and the separation between conductors. In this way, a general “virtual chart” solution is obtained, which contains the solution for any frequency and for any separation of the conductors, and stores it in a compact separated representations form, which can be easily embedded on a more general software for the design of electrical installations. The approach presented in this work for rectangular conductors can be easily extended to conductors with an arbitrary shape.

  12. Application of the parametric proper generalized decomposition to the frequency-dependent calculation of the impedance of an AC line with rectangular conductors

    Science.gov (United States)

    Sancarlos-González, Abel; Pineda-Sanchez, Manuel; Puche-Panadero, Ruben; Sapena-Bano, Angel; Riera-Guasp, Martin; Martinez-Roman, Javier; Perez-Cruz, Juan; Roger-Folch, Jose

    2017-12-01

    AC lines of industrial busbar systems are usually built using conductors with rectangular cross sections, where each phase can have several parallel conductors to carry high currents. The current density in a rectangular conductor, under sinusoidal conditions, is not uniform. It depends on the frequency, on the conductor shape, and on the distance between conductors, due to the skin effect and to proximity effects. Contrary to circular conductors, there are not closed analytical formulas for obtaining the frequency-dependent impedance of conductors with rectangular cross-section. It is necessary to resort to numerical simulations to obtain the resistance and the inductance of the phases, one for each desired frequency and also for each distance between the phases' conductors. On the contrary, the use of the parametric proper generalized decomposition (PGD) allows to obtain the frequency-dependent impedance of an AC line for a wide range of frequencies and distances between the phases' conductors by solving a single simulation in a 4D domain (spatial coordinates x and y, the frequency and the separation between conductors). In this way, a general "virtual chart" solution is obtained, which contains the solution for any frequency and for any separation of the conductors, and stores it in a compact separated representations form, which can be easily embedded on a more general software for the design of electrical installations. The approach presented in this work for rectangular conductors can be easily extended to conductors with an arbitrary shape.

  13. A comparative study on the performance and environmental characteristics of R410A and R22 residential air conditioners

    International Nuclear Information System (INIS)

    Chen, W.

    2008-01-01

    R410A is a long-term alternative refrigerant with zero ODP (ozone-depleting-potential) for replacing R22. In this paper, four sets of comparable R410A and R22 split-type residential A/C (air conditioners) were developed and then their performance was comparatively studied using one simulation software. The A/C performance compared in this paper included the cooling capacity, EER (energy efficiency ratio), annual power consumption of A/C and the global warming impact of refrigerants adopted by the A/C. It was concluded that the adoption of R410A could be helpful for A/C to decrease their heat exchanger size or improve their operation efficiency for power saving. Moreover, compared to R22, R410A could in fact help alleviate its overall impact on global warming through significantly reducing the indirect global warming impact caused by operating R410A A/C

  14. Vortex dynamics and irreversibility line in optimally doped SmFeAsO0.8F0.2 from ac susceptibility and magnetization measurements

    Science.gov (United States)

    Prando, G.; Carretta, P.; de Renzi, R.; Sanna, S.; Palenzona, A.; Putti, M.; Tropeano, M.

    2011-05-01

    Ac susceptibility and static magnetization measurements were performed in the optimally doped SmFeAsO0.8F0.2 superconductor. The field-temperature phase diagram of the superconducting state was drawn, and, in particular, the features of the flux lines were derived. The dependence of the intragrain depinning energy on the magnetic field intensity was derived in the thermally activated flux-creep framework, enlightening a typical 1/H dependence in the high-field regime. The intragrain critical current density was extrapolated in the zero-temperature and zero-magnetic-field limit, showing a remarkably high value Jc0(0)~2×107 A/cm2, which demonstrates that this material is rather interesting for potential future technological applications.

  15. Comparative investigation of thermoelectric air-conditioners versus vapour compression and absorption air-conditioners

    International Nuclear Information System (INIS)

    Riffat, S.B.; Qiu Guoquan

    2004-01-01

    This paper compares the performance of three types of domestic air-conditioners, namely the vapour compression air-conditioner (VCAC), the absorption air-conditioner (AAC) and the thermoelectric air-conditioner (TEAC). The basic cycles of the three types of air-conditioning systems are described and methods to calculate their coefficients of performance are presented. General specification data for each type of air-conditioner are given, and performance characteristics are presented. The comparison shows that although VCACs have the advantages of high COP and low purchase price, use of these systems will be phased out due to their contribution to the greenhouse effect and depletion of the ozone layer. AACs are generally bulky, complex and expensive but operate on thermal energy, so their operational consumption is low. TEACs are environmental friendly, simple and reliable but still very expensive at present. Their low COP is an additional factor limiting their application for domestic cooling. TEACs however, have a large potential market as air-conditioners for small enclosures, such as cars and submarine cabins, where the power consumption would be low, or safety and reliability would be important

  16. Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines

    International Nuclear Information System (INIS)

    Cong Haoxi; Li Qingmin; Xing Jinyuan; Li Jinsong; Chen Qiang

    2015-01-01

    The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low-voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines. (paper)

  17. Technical and Economic Aspects of Designing an Efficient Room Air-Conditioner Program in India

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.

    2017-09-05

    Several studies have projected a massive increase in the demand for air conditioners (ACs) over the next two decades in India. By 2030, room ACs could add 140 GW to the peak load, equivalent to over 30% of the total projected peak load. Therefore, there is significant interest among policymakers, regulators, and utilities in managing room AC demand by enhancing energy efficiency. Building on the historical success of the Indian Bureau of Energy Efficiency’s star-labeling program, Energy Efficiency Services Limited recently announced a program to accelerate the sale of efficient room ACs using bulk procurement, similar to their successful UJALA light-emitting diode (LED) bulk procurement program. This report discusses some of the key considerations in designing a bulk procurement or financial incentive program for enhancing room AC efficiency in India. We draw upon our previous research to demonstrate the overall technical potential and price impact of room AC efficiency improvement and its technical feasibility in India. We also discuss the importance of using low global warming potential (GWP) refrigerants and smart AC equipment that is demand response (DR) ready.

  18. 77 FR 28519 - Test Procedure Guidance for Room Air Conditioners, Residential Dishwashers, and Residential...

    Science.gov (United States)

    2012-05-15

    ... Guidance for Room Air Conditioners, Residential Dishwashers, and Residential Clothes Washers: Public... procedures for room air conditioners, residential dishwashers, and residential clothes washers. DATES: DOE...'s existing test procedures for residential room air conditioners, residential dishwashers, and...

  19. Increased Ac excision (iae): Arabidopsis thaliana mutations affecting Ac transposition

    International Nuclear Information System (INIS)

    Jarvis, P.; Belzile, F.; Page, T.; Dean, C.

    1997-01-01

    The maize transposable element Ac is highly active in the heterologous hosts tobacco and tomato, but shows very much reduced levels of activity in Arabidopsis. A mutagenesis experiment was undertaken with the aim of identifying Arabidopsis host factors responsible for the observed low levels of Ac activity. Seed from a line carrying a single copy of the Ac element inserted into the streptomycin phosphotransferase (SPT) reporter fusion, and which displayed typically low levels of Ac activity, were mutagenized using gamma rays. Nineteen mutants displaying high levels of somatic Ac activity, as judged by their highly variegated phenotypes, were isolated after screening the M2 generation on streptomycin-containing medium. The mutations fall into two complementation groups, iae1 and iae2, are unlinked to the SPT::Ac locus and segregate in a Mendelian fashion. The iae1 mutation is recessive and the iae2 mutation is semi-dominant. The iae1 and iae2 mutants show 550- and 70-fold increases, respectively, in the average number of Ac excision sectors per cotyledon. The IAE1 locus maps to chromosome 2, whereas the SPT::Ac reporter maps to chromosome 3. A molecular study of Ac activity in the iae1 mutant confirmed the very high levels of Ac excision predicted using the phenotypic assay, but revealed only low levels of Ac re-insertion. Analyses of germinal transposition in the iae1 mutant demonstrated an average germinal excision frequency of 3% and a frequency of independent Ac re-insertions following germinal excision of 22%. The iae mutants represents a possible means of improving the efficiency of Ac/Ds transposon tagging systems in Arabidopsis, and will enable the dissection of host involvement in Ac transposition and the mechanisms employed for controlling transposable element activity

  20. 16 CFR Appendix E to Part 305 - Room Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Room Air Conditioners E Appendix E to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS RULE... Appendix E to Part 305—Room Air Conditioners Range Information Manufacturer's rated cooling capacity in Btu...

  1. Effects of natural and synthetic soil conditioners on soil moisture ...

    African Journals Online (AJOL)

    The efficacy of a natural soil conditioner, Coco-Peat (C-P), and synthetic soil conditioners, Terawet (T-200) and Teraflow (T-F), in improving soil moisture content were examined on five Ghanaian soil series (Akroso, Akuse, Amo, Hake and Oyarifa). In general, the water retention of T-200 and C-P treated soils were similar ...

  2. Utilization of air conditioner condenser as water heater in an effort to energy conservation

    Science.gov (United States)

    Sonawan, Hery; Saputro, Panji; Kurniawan, Iden Muhtar

    2018-04-01

    This paper presents an experimental study of utilization of air conditioner condenser as water heater. Modification of existing air conditioner system is an effort to harvest waste heat energy from condenser. Modification is conducted in order to test the system into two mode tests, first mode with one condenser and second mode with two condensers. Harvesting the waste heat from condenser needs a theoretical and practice study to see how much the AC performance changes if modifications are made. It should also be considered how the technique of harvesting waste heat for water heating purposes. From the problem, this paper presents a comparison between AC performance before and after modification. From the experiment, an increase in compressor power consumption is 4.3% after adding a new condenser. The hot water temperature is attained to 69 °C and ready for warm bath. The increase in power consumption is not too significant compared to the attainable hot water temperature. Also seen that the value of condenser Performance Factor increase from 5.8 to 6.25 or by 7.8%.

  3. Effect of central ventilation and air conditioner system on the concentration and health risk from airborne polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Lv, Jinze; Zhu, Lizhong

    2013-03-01

    Central ventilation and air conditioner systems are widely utilized nowadays in public places for air exchange and temperature control, which significantly influences the transfer of pollutants between indoors and outdoors. To study the effect of central ventilation and air conditioner systems on the concentration and health risk from airborne pollutants, a spatial and temporal survey was carried out using polycyclic aromatic hydrocarbons (PAHs) as agent pollutants. During the period when the central ventilation system operated without air conditioning (AC-off period), concentrations of 2-4 ring PAHs in the model supermarket were dominated by outdoor levels, due to the good linearity between indoor air and outdoor air (r(p) > 0.769, p air conditioner systems were working simultaneously (AC-on period), although the total levels of PAHs were increased, the concentrations and percentage of the particulate PAHs indoors declined significantly. The BaP equivalency (BaPeq) concentration indicated that utilization of air conditioning reduced the health risks from PAHs in the model supermarket.

  4. AC Test Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Psychrometric Test Chamber’s primary purpose is to evaluate the performance of split type central air conditioners and heat pumps in the cooling capacity range...

  5. On-Line Testing and Reconfiguration of Field Programmable Gate Arrays (FPGAs) for Fault-Tolerant (FT) Applications in Adaptive Computing Systems (ACS)

    National Research Council Canada - National Science Library

    Abramovici, Miron

    2002-01-01

    Adaptive computing systems (ACS) rely on reconfigurable hardware to adapt the system operation to changes in the external environment, and to extend mission capability by implementing new functions on the same hardware platform...

  6. An experimental and theoretical study on an injection-assisted air-conditioner using R32 in the refrigeration cycle

    International Nuclear Information System (INIS)

    Qv, Dehu; Dong, Bingbing; Cao, Lin; Ni, Long; Wang, Jijin; Shang, Runxin; Yao, Yang

    2017-01-01

    Highlights: • An advanced injection-assisted air-conditioner (IAC) using R32 was proposed. • In the whole day-night cycle, cooling capacity and energy efficiency ratio of the IAC were enhanced dramatically. • The injection duration of 8 s maximized the IAC cooling potential. • Two-phase injection attained the highest exergetic efficiency approximating 50% or more. • The economic and environmental benefits of the IAC were demonstrated. - Abstract: An air-conditioner (AC) that uses refrigerant R32 assisted with one-phase vapor injection shows high energy efficiency and low discharge temperature in the heat-pump cycle, but the performance is not satisfactory in the refrigeration cycle. In this study, an improved injection cycle consisting of one-phase vapor injection mode and two-phase injection mode is proposed and integrated into an AC using R32, which is now referred to as an advanced injection-assisted air-conditioner (IAC). Through an experimental and theoretical study, an optimal injection duration of 8 s is attained for maximizing the refrigeration potential of the IAC. Furthermore, in an entire day–night cycle, both the cooling capacity and energy efficiency ratio (EER) of the IAC within the two-phase injection cycle are enhanced by 25% and 32%, respectively, compared with those of a noninjection-assisted AC. Moreover, two-phase injection offers the highest exergetic efficiency, approximately 50% or more in the refrigeration cycle, exhibiting remarkable thermodynamic performance of the IAC. In addition, compared to the conventional AC using R410A, the IAC using R32 within a two-phase injection cycle demonstrates reasonable payback performance and substantial reduction in carbon dioxide and sulfur dioxide emissions in the refrigeration cycle.

  7. [Gohieria fusca found in dust of air-conditioner filters].

    Science.gov (United States)

    Qiang, Chai; Xiao-Dong, Zhan; Wei, Guo; Chao-Pin, Li

    2017-09-25

    To investigate the pollution status of Gohieria fusca in the air conditioner-filters of different places in Wuhu City. The dust samples were collected from the filters of air-conditioners in dining rooms, shopping malls, hotels and households between June and September, 2013, and G. fusca was detected in the dust samples. There were 430 dust samples collected and 98 were G. fusca positive with the breeding rate of 22.79%. The difference of breeding rates of G. fusca were statistically significant among the different places ( χ 2 =18.294, P air-conditioner filters in Wuhu City gravely.

  8. Ventilation air conditioner for a reactor container

    International Nuclear Information System (INIS)

    Ikegame, Noboru; Nakagawa, Takeshi.

    1980-01-01

    Purpose: To suppress the variations in the internal pressure of a reactor container and smoothly ventilate the reactor container. Constitution: The air conditioner provides an air-flow-rate-control damper, a purge-air supply fan, and a filter device in the air-supply pipe of a reactor container. Furthermore, it provides a pressure difference detector at a part of the container. The air-flow-rate-control damper is connected electrically through a position-modulator-comparison amplifier to the pressure difference detector. When the filtration becomes insufficient by clogging of the filter device and the internal pressure increased abruptly in the container, the pressure-difference detector can detect it, and the damper is operated by a pressure regulator and the comparator so as to control the air flow to the container. Thus, the internal pressure variation is controlled so as to easily ventilate the container. (J.P.N.)

  9. Requirements of office air conditioners. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, W

    1988-01-01

    New building designs and experiences gained in the past are reponsible for the considerable changes the requirements of air conditioners have gone through in recent years. Details are given on an exemplary air conditioning system designed for the Colonia Insurances building complex located in the city of Cologne. The ventilation requirements and hygienic conditions set out for air conditioned rooms call for outside air supplies, the careful selection of air intakes, and the filtering of intake air. Details are given on the efficiency and limits of combined natural window ventilation/artificial ventilation systems, the influence of window types, and the influence of building structures. The pressure conditions to be expected for larger building complexes in the case of natural ventilation should be assessed with the help of models put to wind tunnel tests.

  10. Formulation of humic-based soil conditioners

    Science.gov (United States)

    Amanova, M. A.; Mamytova, G. A.; Mamytova, B. A.; Kydralieva, K. A.; Jorobekova, Sh. J.

    2009-04-01

    The goal of the study is to prepare soil conditioners (SC) able to carry out the following functions: (i) the chemical conditioning of soil mainly comprising the adjustment of pH, (ii) the balancing of inorganic nutrients, (iii) the physical conditioning of soil mainly comprising the improvement of water permeability, air permeability and water retention properties, and (iv) improvement of the ecological system concerning of useful microorganisms activity in the soil. The SC was made of a mixture of inorganic ingredients, a chemical composition and physical and chemical properties of which promoted improvement of physical characteristic of soil and enrichment by its mineral nutritious elements. In addition to aforesaid ingredients, this soil conditioner contains agronomical-valued groups of microorganisms having the function promoting the growth of the crop. As organic component of SC humic acids (HA) was used. HA serve many major functions that result in better soil and plant health. In soil, HA can increase microbial and mycorrhizal activity while enhancing nutrient uptake by plant roots. HA work as a catalyst by stimulating root and plant growth, it may enhance enzymatic activity that in turn accelerates cell division which can lead to increased yields. HA can help to increase crop yields, seed germination, and much more. In short, humic acids helps keep healthy plants health. The first stage goal was to evaluate mineral and organic ingredients for formulation of SC. Soil conditioners assessed included ash and slag. The use of slags has been largelly used in agriculture as a source of lime and phosphoric acid. The silicic acid of slags reduces Al-acitivity thus, promoting a better assimilation of P-fertilizer by plants. Additionally, silicic acid is also known to improve soil moisture capacity, thus enhancing soil water availability to plants. Physico-chemical characteristics of ash and slag were determined, as a total - about 20 samples. Results include

  11. Effects of water management practices on residue decomposition and degradation of Cry1Ac protein from crop-wild Bt rice hybrids and parental lines during winter fallow season.

    Science.gov (United States)

    Xiao, Manqiu; Dong, Shanshan; Li, Zhaolei; Tang, Xu; Chen, Yi; Yang, Shengmao; Wu, Chunyan; Ouyang, Dongxin; Fang, Changming; Song, Zhiping

    2015-12-01

    Rice is the staple diet of over half of the world's population and Bacillus thuringiensis (Bt) rice expressing insecticidal Cry proteins is ready for deployment. An assessment of the potential impact of Bt rice on the soil ecosystem under varied field management practices is urgently required. We used litter bags to assess the residue (leaves, stems and roots) decomposition dynamics of two transgenic rice lines (Kefeng6 and Kefeng8) containing stacked genes from Bt and sck (a modified CpTI gene encoding a cowpea trypsin inhibitor) (Bt/CpTI), a non-transgenic rice near-isoline (Minghui86), wild rice (Oryza rufipogon) and crop-wild Bt rice hybrid under contrasting conditions (drainage or continuous flooding) in the field. No significant difference was detected in the remaining mass, total C and total N among cultivars under aerobic conditions, whereas significant differences in the remaining mass and total C were detected between Kefeng6 and Kefeng8 and Minghui86 under the flooded condition. A higher decomposition rate constant (km) was measured under the flooded condition compared with the aerobic condition for leaf residues, whereas the reverse was observed for root residues. The enzyme-linked immunosorbent assay (ELISA), which was used to monitor the changes in the Cry1Ac protein in Bt rice residues, indicated that (1) the degradation of the Cry1Ac protein under both conditions best fit first-order kinetics, and the predicted DT50 (50% degradation time) of the Cry1Ac protein ranged from 3.6 to 32.5 days; (2) the Cry1Ac protein in the residue degraded relatively faster under aerobic conditions; and (3) by the end of the study (~154 days), the protein was present at a low concentration in the remaining residues under both conditions. The degradation rate constant was negatively correlated with the initial carbon content and positively correlated with the initial Cry1Ac protein concentration, but it was only correlated with the mass decomposition rate constants under

  12. Statistical analysis of the count and profitability of air conditioners.

    Science.gov (United States)

    Rady, El Houssainy A; Mohamed, Salah M; Abd Elmegaly, Alaa A

    2018-08-01

    This article presents the statistical analysis of the number and profitability of air conditioners in an Egyptian company. Checking the same distribution for each categorical variable has been made using Kruskal-Wallis test.

  13. Lemongrass-Incorporated Tissue Conditioner Against Candida albicans Culture

    Science.gov (United States)

    Amornvit, Pokpong; Srithavaj, Theerathavaj

    2014-01-01

    Background: Tissue conditioner is applied popularly with dental prosthesis during wound healing process but it becomes a reservoir of oral microbiota, especially Candida species after long-term usage. Several antifungal drugs have been mixed with this material to control fungal level. In this study, lemongrass essential oil was added into COE-COMFORT tissue conditioner before being determined for anti-Candida efficacy. Materials and Methods: Lemongrass (Cymbopogon citratus) essential oil was primarily determined for antifungal activity against C. albicans American type culture collection (ATCC) 10231 and MIC (minimum inhibitory concentration) value by agar disk diffusion and broth microdilution methods, respectively. COE-COMFORT tissue conditioner was prepared as recommended by the manufacturer after a fixed volume of the oil at its MIC or higher concentrations were mixed thoroughly in its liquid part. Antifungal efficacy of the tissue conditioner with/without herb was finally analyzed. Results: Lemongrass essential oil displayed potent antifungal activity against C. albicans ATCC 10231and its MIC value was 0.06% (v/v). Dissimilarly, the tissue conditioner containing the oil at MIC level did not cease the growth of the tested fungus. Both reference and clinical isolates of C. albicans were completely inhibited after exposed to the tissue conditioner containing at least 0.25% (v/v) of the oil (approximately 4-time MIC). The tissue conditioner without herb or with nystatin was employed as negative or positive control, respectively. Conclusion: COE-COMFORT tissue conditioner supplemented with lemongrass essential oil obviously demonstrated another desirable property as in vitro anti-Candida efficacy to minimize the risk of getting Candidal infection. PMID:25177638

  14. Ao38, a new cell line from eggs of the black witch moth, Ascalapha odorata (Lepidoptera: Noctuidae, is permissive for AcMNPV infection and produces high levels of recombinant proteins

    Directory of Open Access Journals (Sweden)

    Zhang Sheng

    2010-07-01

    Full Text Available Abstract Background The insect cell line is a critical component in the production of recombinant proteins in the baculovirus expression system and new cell lines hold the promise of increasing both quantity and quality of protein production. Results Seventy cell lines were established by single-cell cloning from a primary culture of cells derived from eggs of the black witch moth (Ascalapha odorata; Lepidoptera, Noctuidae. Among 8 rapidly growing lines, cell line 38 (Ao38 was selected for further analysis, based on susceptibility to AcMNPV infection and production of secreted alkaline phosphatase (SEAP from a baculovirus expression vector. In comparisons with low-passage High Five (BTI-Tn-5B1-4 cells, infected Ao38 cells produced β-galactosidase and SEAP at levels higher (153% and 150%, respectively than those measured from High Five cells. Analysis of N-glycans of SEAP produced in Ao38 cells revealed two N-glycosylation sites and glycosylation patterns similar to those reported for High Five and Sf9 cells. Glycopeptide isoforms consisted of pauci- or oligomannose, with and without fucose on N-acetylglucosamine(s linked to asparagine residues. Estimates of Ao38 cell volume suggest that Ao38 cells are approximately 2.5× larger than Sf9 cells but only approximately 74% of the size of High Five cells. Ao38 cells were highly susceptible to AcMNPV infection, similar to infectivity of Sf9 cells. Production of infectious AcMNPV budded virions from Ao38 cells peaked at approximately 4.5 × 107 IU/ml, exceeding that from High Five cells while lower than that from Sf9 cells. Ao38 cells grew rapidly in stationary culture with a population doubling time of 20.2 hr, and Ao38 cells were readily adapted to serum-free medium (Sf-900III and to a suspension culture system. Analysis of Ao38 and a parental Ascalapha odorata cell line indicated that these lines were free of the alphanodavirus that was recently identified as an adventitious agent in High Five cell

  15. Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners.

    Science.gov (United States)

    Batterman, S; Du, L; Mentz, G; Mukherjee, B; Parker, E; Godwin, C; Chin, J-Y; O'Toole, A; Robins, T; Rowe, Z; Lewis, T

    2012-06-01

    This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84±27%, but dropped to 63±33% in subsequent seasons. In months when households were not visited, use averaged only 34±30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. Environmental tobacco smoke (ETS) increased particulate matter (PM) levels by about 14 μg/m3 and was often detected using ETS-specific tracers despite restrictions on smoking in the house as reported on questionnaires administered to caregivers. PM concentrations depended on season, filter usage, relative humidity, air exchange ratios, number of children, outdoor PM levels, sweeping/dusting, and presence of a central air conditioner (AC). Free-standing air filters can be an effective intervention that provides substantial reductions in PM concentrations if the filters are used. However, filter use was variable across the study population and declined over the study duration, and

  16. Effect of Tower Shadow and Wind Shear in a Wind Farm on AC Tie-Line Power Oscillations of Interconnected Power Systems

    DEFF Research Database (Denmark)

    Tan, Jin; Hu, Weihao; Wang, Xiaoru

    2013-01-01

    This paper describes a frequency domain approach for evaluating the impact of tower shadow and wind shear effects (TSWS) on tie-line power oscillations. A simplified frequency domain model of an interconnected power system with a wind farm is developed. The transfer function, which relates the tie......-line power variation to the mechanical power variation of a wind turbine, and the expression of the maximum magnitude of tie-line power oscillations are derived to identify the resonant condition and evaluate the potential risk. The effects of the parameters on the resonant magnitude of the tie-line power...... are also discussed. The frequency domain analysis reveals that TSWS can excite large tie-line power oscillations if the frequency of TSWS approaches the tie-line resonant frequency, especially in the case that the wind farm is integrated into a relatively small grid and the tie-line of the interconnected...

  17. Orbiting compressor for residential air-conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Woo Young; Ahn, Jong Min [Department of Mechanical Engineering, University of Incheon, 12-1 Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea)

    2010-01-15

    A new type of compressor, called an orbiting compressor, is introduced in this paper. The orbiting compressor is characterized by an orbiting piston, and the piston or orbiter consists of a circular base plate and a ring type vane protruding vertically from the base plate. The orbiter is made to orbit in an annular space formed between two concentric circular walls via an Oldham-ring mechanism, producing two sealed gas pockets on both sides of the vane wrap with a 180 phase difference. This operating mechanism leads to alternating compression and discharge processes, which results in low torque variation. The orbiting compressor has been designed for an R410A residential air conditioner with a cooling capacity of 10.0 kW. The performance of the orbiting compressor model has been analytically investigated, where the volumetric, adiabatic and mechanical efficiencies were calculated to be 94.8%, 90.4% and 93.4%, respectively for the ARI condition. The EER was estimated to be about 10.86 with a motor efficiency of 89%. (author)

  18. High efficiency novel window air conditioner

    International Nuclear Information System (INIS)

    Bansal, Pradeep

    2015-01-01

    Highlights: • Use of novel refrigerant mixture of R32/R125 (85/15% molar conc.) to reduce global warming and improve energy efficiency. • Use of novel features such as electronically commuted motor (ECM) fan motor, slinger and sub-merged sub-cooler. • Energy savings of up to 0.1 Quads per year in USA and much more in Asia/Middle East where WACs are used in large numbers. • Payback period of only 1.4 years of the novel efficient WAC. - Abstract: This paper presents the results of an experimental and analytical evaluation of measures to raise the efficiency of window air conditioners (WAC). In order to achieve a higher energy efficiency ratio (EER), the original capacity of a baseline R410A unit was reduced by replacing the original compressor with a lower capacity but higher EER compressor, while all heat exchangers and the chassis from the original unit were retained. Subsequent major modifications included – replacing the alternating current fan motor with a brushless high efficiency electronically commutated motor (ECM) motor, replacing the capillary tube with a needle valve to better control the refrigerant flow and refrigerant set points, and replacing R410A with a ‘drop-in’ lower global warming potential (GWP) binary mixture of R32/R125 (85/15% molar concentration). All these modifications resulted in significant enhancement in the EER of the baseline WAC. Further, an economic analysis of the new WAC revealed an encouraging payback period

  19. Air conditioner for radioactive material handling facility

    International Nuclear Information System (INIS)

    Tanaka, Takeaki.

    1991-01-01

    An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 μm are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 μm grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10 -13 to 10 -14 μci/cm 3 in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. (I.N.)

  20. Embedding quantum into classical: contextualization vs conditionalization.

    Directory of Open Access Journals (Sweden)

    Ehtibar N Dzhafarov

    Full Text Available We compare two approaches to embedding joint distributions of random variables recorded under different conditions (such as spins of entangled particles for different settings into the framework of classical, Kolmogorovian probability theory. In the contextualization approach each random variable is "automatically" labeled by all conditions under which it is recorded, and the random variables across a set of mutually exclusive conditions are probabilistically coupled (imposed a joint distribution upon. Analysis of all possible probabilistic couplings for a given set of random variables allows one to characterize various relations between their separate distributions (such as Bell-type inequalities or quantum-mechanical constraints. In the conditionalization approach one considers the conditions under which the random variables are recorded as if they were values of another random variable, so that the observed distributions are interpreted as conditional ones. This approach is uninformative with respect to relations between the distributions observed under different conditions because any set of such distributions is compatible with any distribution assigned to the conditions.

  1. AC Initiation System.

    Science.gov (United States)

    An ac initiation system is described which uses three ac transmission signals interlocked for safety by frequency, phase, and power discrimination...The ac initiation system is pre-armed by the application of two ac signals have the proper phases, and activates a load when an ac power signal of the proper frequency and power level is applied. (Author)

  2. Feasibility study on novel room air conditioner with natural cooling capability

    International Nuclear Information System (INIS)

    Han, Zongwei; Liu, Qiankun; Zhang, Yanqing; Zhang, Shuwei; Liu, Jiangzhen; Li, Weiliang

    2016-01-01

    Highlights: • A novel heat pipe combined evaporative cooling room air conditioner is constructed. • The mathematical model of the air conditioner is established. • The reliability of the model is verified by experiments. • The performance of the novel and conventional air conditioner is compared. • The applicability of the novel air conditioner in different areas is investigated. - Abstract: In order to improve the energy efficiency of room air conditioners, this paper proposed a new air conditioner that combined evaporative cooling technology, separate type heat pipe technology, and vapour compression refrigeration technology (called “combined air conditioner”). The mathematical model of the air conditioner was established and its reliability was verified by experiments. Based on the model, the simulation of the operating performance of the combined air conditioner and a conventional air conditioner was studied in typical climate regions during the cooling period, with the following results: In cold and dry areas like Shenyang, compared with the conventional air conditioner, the average cooling coefficient of performance (COP) of the combined air conditioner was increased by 27.40%. As the climate gradually became warmer and humidity gradually increased, the running time of the heat pipe cooling mode was gradually reduced, and then the energy-saving effect of the combined air conditioner became worse. For example, in the hot and humid Guangzhou, the energy saving rate was only 11.81%. Therefore, it was found that the combined air conditioner had good energy-saving potential in cold and dry areas.

  3. Spectra of conditionalization and typicality in the multiverse

    Science.gov (United States)

    Azhar, Feraz

    2016-02-01

    An approach to testing theories describing a multiverse, that has gained interest of late, involves comparing theory-generated probability distributions over observables with their experimentally measured values. It is likely that such distributions, were we indeed able to calculate them unambiguously, will assign low probabilities to any such experimental measurements. An alternative to thereby rejecting these theories, is to conditionalize the distributions involved by restricting attention to domains of the multiverse in which we might arise. In order to elicit a crisp prediction, however, one needs to make a further assumption about how typical we are of the chosen domains. In this paper, we investigate interactions between the spectra of available assumptions regarding both conditionalization and typicality, and draw out the effects of these interactions in a concrete setting; namely, on predictions of the total number of species that contribute significantly to dark matter. In particular, for each conditionalization scheme studied, we analyze how correlations between densities of different dark matter species affect the prediction, and explicate the effects of assumptions regarding typicality. We find that the effects of correlations can depend on the conditionalization scheme, and that in each case atypicality can significantly change the prediction. In doing so, we demonstrate the existence of overlaps in the predictions of different "frameworks" consisting of conjunctions of theory, conditionalization scheme and typicality assumption. This conclusion highlights the acute challenges involved in using such tests to identify a preferred framework that aims to describe our observational situation in a multiverse.

  4. A Flexible Load Control Strategy for Distribution Network to Reduce the Line Losses and to Eliminate the Transmission Congestion

    Directory of Open Access Journals (Sweden)

    Beibei Wang

    2017-01-01

    Full Text Available There are many uncertain factors in the modern distribution network, including the access of renewable energy sources and the heavy load level. The existence of these factors has brought challenges to the stability of the power distribution network, as well as increasing the risk of exceeding transmission capacity of distribution lines. The appearance of flexible load control technology provides a new idea to solve the above problems. Air conditioners (ACs account for a great proportion of all loads. In this paper, the model of dispatching AC loads in the regional power grid is constructed, and the direct load control (DLC method is adopted to reduce the load of ACs. An improved tabu search technique is proposed to solve the problem of network dispatch in distribution systems in order to reduce the resistive line losses and to eliminate the transmission congestion in lines under normal operating conditions. The optimal node solution is obtained to find the best location and reduction capacity of ACs for load control. To demonstrate the validity and effectiveness of the proposed method, a test system is studied. The numerical results are also given in this article, which reveal that the proposed method is promising.

  5. 77 FR 8178 - Test Procedures for Central Air Conditioners and Heat Pumps: Public Meeting

    Science.gov (United States)

    2012-02-14

    .... EERE-2010-BT-TP-0038] Test Procedures for Central Air Conditioners and Heat Pumps: Public Meeting... methodologies and gather comments on testing residential central air conditioners and heat pumps designed to use... residential central air conditioners and heat pumps that are single phase with rated cooling capacities less...

  6. 48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.

    Science.gov (United States)

    2010-10-01

    ... and Air Conditioners. 52.223-12 Section 52.223-12 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor shall...

  7. 16 CFR 305.12 - Labeling for central air conditioners, heat pumps, and furnaces.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Labeling for central air conditioners, heat... (âAPPLIANCE LABELING RULEâ) Required Disclosures § 305.12 Labeling for central air conditioners, heat pumps, and furnaces. (a) Layout. All energy labels for central air conditioners, heat pumps, and...

  8. 75 FR 7987 - Energy Conservation Standards for Residential Clothes Dryers and Room Air Conditioners: Public...

    Science.gov (United States)

    2010-02-23

    ... Conservation Standards for Residential Clothes Dryers and Room Air Conditioners: Public Meeting and... conservation standards for residential clothes dryers and room air conditioners; the analytical framework..., Mailstop EE-2J, Public Meeting for Residential Clothes Dryers and Room Air Conditioners, EERE-2007-BT-STD...

  9. 10 CFR 431.92 - Definitions concerning commercial air conditioners and heat pumps.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Definitions concerning commercial air conditioners and... PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps § 431.92 Definitions concerning commercial air conditioners and heat pumps. The following definitions apply...

  10. 75 FR 72739 - Compliance Testing Procedures: Correction Factor for Room Air Conditioners

    Science.gov (United States)

    2010-11-26

    ...: Correction Factor for Room Air Conditioners AGENCY: Office of the General Counsel, Department of Energy (DOE... air conditioners. The petition seeks temporary enforcement forbearance, or in the alternative, a... procedures for room air conditioners. Public comment is requested on whether DOE should grant the petition...

  11. 75 FR 14368 - Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps: Public...

    Science.gov (United States)

    2010-03-25

    ... Conservation Standards for Residential Central Air Conditioners and Heat Pumps: Public Meeting and Availability... conservation standards for residential central air conditioners and heat pumps; the analytical framework..., Mailstop EE-2J, Public Meeting for Residential Central Air Conditioners and Heat Pumps, EERE-2008-BT- STD...

  12. 21 CFR 872.3750 - Bracket adhesive resin and tooth conditioner.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bracket adhesive resin and tooth conditioner. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3750 Bracket adhesive resin and tooth conditioner. (a) Identification. A bracket adhesive resin and tooth conditioner is a device...

  13. Air-conditioner filters enriching dust mites allergen.

    Science.gov (United States)

    Zhan, Xiaodong; Li, Chaopin; Xu, Haifeng; Xu, Pengfei; Zhu, Haibin; Diao, Jidong; Li, Na; Zhao, Beibei

    2015-01-01

    We detected the concentration of dust mites allergen (Der f1 & Der p1) in the air of different places before and after the starting of air-conditioners in Wuhu City, Anhui, China, and to discuss the relation between the dust mites allergen in air-conditioner filters and the asthma attack. The dust samples were collected from the air-conditioner filters in dining rooms, shopping malls, hotels and households respectively. Concentrations of dust mites major group allergen 1 (Der f 1, Der p1) were detected with enzyme linked immunosorbent assay (ELISA), and the dust mite immune activities were determined by dot-ELISA. The concentration of Der f1 in dining rooms, shopping malls, hotels and households was 1.52 μg/g, 1.24 μg/g, 1.31 μg/g and 1.46 μg/g respectively, and the concentration of Der p1 in above-mentioned places was 1.23 μg/g, 1.12 μg/g, 1.16 μg/g and 1.18 μg/g respectively. The concentration of Der f1 & Der p1 in air was higher after the air-conditioners starting one hours later, and the difference was significant (Pair-conditioner filters can enrich dust mites major group allergen, and the allergens can induce asthma. The air-conditioner filters shall be cleaned or replaced regularly to prevent or reduce accumulation of the dust mites and its allergens.

  14. Design of a signal conditioner for the Fermilab Magnet Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Giannelli, Pietro [Turin Polytechnic

    2012-01-01

    This thesis describes the design of a remotely-programmable signal conditioner for the harmonic measurement of accelerator magnets. A 10-channel signal conditioning circuit featuring bucking capabilities was designed from scratch and implemented to the level of the printed circuit board layout. Other system components were chosen from those available on the market. Software design was started with the definition of routine procedures. This thesis is part of an upgrade project for replacing obsolescent automated test equipment belonging to the Fermilab Magnet Test Facility. The design started with a given set of requirements. Using a top-down approach, all the circuits were designed and their expected performances were theoretically predicted and simulated. A limited prototyping phase followed. The printed circuit boards were laid out and routed using a CAD software and focusing the design on maximum electromagnetic interference immunity. An embedded board was selected for controlling and interfacing the signal conditioning circuitry with the instrumentation network. Basic low level routines for hardware access were defined. This work covered the entire design process of the signal conditioner, resulting in a project ready for manufacturing. The expected performances are in line with the requirements and, in the cases where this was not possible, approval of trade-offs was sought and received from the end users. Part I deals with the global structure of the signal conditioner and the subdivision in functional macro-blocks. Part II treats the hardware design phase in detail, covering the analog and digital circuits, the printed circuit layouts, the embedded controller and the power supply selection. Part III deals with the basic hardware-related routines to be implemented in the final software.

  15. Control Technologies for Room Air-conditioner and Packaged Air-conditioner

    Science.gov (United States)

    Ito, Nobuhisa

    Trends of control technologies about air-conditioning machineries, especially room or packaged air conditioners, are presented in this paper. Multiple air conditioning systems for office buildings are mainly described as one application of the refrigeration cycle control technologies including sensors for thermal comfort and heating/ cooling loads are also described as one of the system control technologies. Inverter systems and related technologies for driving variable speed compressors are described in both case of including induction motors and brushless DC motors. Technologies for more accurate control to meet various kind of regulations such as ozone layer destruction, energy saving and global warming, and for eliminating harmonic distortion of power source current, as a typical EMC problem, will be urgently desired.

  16. 10 CFR Appendix F to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Room Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... of Room Air Conditioners F Appendix F to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Conditioners 1. Test method. The test method for testing room air conditioners shall consist of application of the methods and conditions in American National Standard (ANS) Z234.1-1972, “Room Air Conditioners...

  17. Design of direct solar PV driven air conditioner

    KAUST Repository

    Huang, Bin-Juine; Hou, Tung-Fu; Hsu, Po-Chien; Lin, Tse-Han; Chen, Yan-Tze; Chen, Chi-Wen; Li, Kang; Lee, K.Y.

    2015-01-01

    ). The measured OPB is found to be greater than 0.98 at instantaneous solar irradiation IT > 600 W m-2 if rpL > 1.71 RF approaches 1.0 (the air conditioner is run in 100% with solar power) at daily-total solar radiation higher than 13 MJ m-2 day-1, if rpL > 3.

  18. Thermionic reactor power conditioner design for nuclear electric propulsion.

    Science.gov (United States)

    Jacobsen, A. S.; Tasca, D. M.

    1971-01-01

    Consideration of the effects of various thermionic reactor parameters and requirements upon spacecraft power conditioning design. A basic spacecraft is defined using nuclear electric propulsion, requiring approximately 120 kWe. The interrelationships of reactor operating characteristics and power conditioning requirements are discussed and evaluated, and the effects on power conditioner design and performance are presented.

  19. Domestic Refrigeration, Freezer, and Window Air Conditioner Service. Teacher Edition.

    Science.gov (United States)

    Clemons, Mark

    This curriculum guide contains six units of instruction for a course in domestic refrigerator, freezer, and window air conditioner service. The units cover the following topics: (1) service fundamentals; (2) mechanical components and functions; (3) electrical components and control devices; (4) refrigerator and freezer service; (5) domestic ice…

  20. Evaluation of ERINA Plus as a coat conditioner in canines

    Directory of Open Access Journals (Sweden)

    Srivastava

    Full Text Available Coat conditioning, deodorant and cleansing properties of ERINA Plus were evaluated in fifty-one dogs of different breeds. More than 80% of dogs showed good to excellent conditioning, deodorant and cleansing effects supported ERINA Plus as safe conditioner shampoo. [Vet. World 2008; 1(12.000: 361-362

  1. Transforming PC Power Supplies into Smart Car Battery Conditioners

    Science.gov (United States)

    Rodriguez-Ascariz, J. M.; Boquete-Vazquez, L.

    2011-01-01

    This paper describes a laboratory project consisting of a PC power supply modification into an intelligent car-battery conditioner with both wireless and wired networking capabilities. Adding a microcontroller to an average PC power supply transforms it into a flexible, intelligent device that can be configured and that is suitable to keep car…

  2. Design of direct solar PV driven air conditioner

    KAUST Repository

    Huang, Bin-Juine

    2015-12-05

    © 2015 Elsevier Ltd. Solar air conditioning system directly driven by stand-alone solar PV is studied. The air conditioning system will suffer from loss of power if the solar PV power generation is not high enough. It requires a proper system design to match the power consumption of air conditioning system with a proper PV size. Six solar air conditioners with different sizes of PV panel and air conditioners were built and tested outdoors to experimentally investigate the running probabilities of air conditioning at various solar irradiations. It is shown that the instantaneous operation probability (OPB) and the runtime fraction (RF) of the air conditioner are mainly affected by the design parameter rpL (ratio of maximum PV power to load power). The measured OPB is found to be greater than 0.98 at instantaneous solar irradiation IT > 600 W m-2 if rpL > 1.71 RF approaches 1.0 (the air conditioner is run in 100% with solar power) at daily-total solar radiation higher than 13 MJ m-2 day-1, if rpL > 3.

  3. Antifungal Effect of a Dental Tissue Conditioner Containing Nystatin-Loaded Alginate Microparticles.

    Science.gov (United States)

    Kim, Hyun-Jin; Son, Jun Sik; Kwon, Tae-Yub

    2018-02-01

    In this in vitro study, nystatin-alginate microparticles were successfully fabricated to control the release of nystatin from a commercial dental tissue conditioner. These nystatin-alginate microparticles were spherical and had a slightly rough surface. The microparticles incorporated into the tissue conditioner were distributed homogeneously throughout the tissue conditioner matrix. The incorporation of the microparticles did not deteriorate the mechanical properties of the original material. The agar diffusion test results showed that the tissue conditioner containing the microparticles had a good antifungal effect against Candida albicans. The nystatin-alginate microparticles efficiently controlled the release of nystatin from the tissue conditioner matrix over the experimental period of 14 days. Moreover, the nystatin-alginate microparticles incorporated in the tissue conditioner showed effective antifungal function even at lower concentrations of nystatin. The current study suggests that the tissue conditioner containing the nystatin-alginate microparticle carrier system has potential as an effective antifungal material.

  4. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Waide, Paul [Navigant Consulting Inc., Chicago, IL (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    This report presents the results of an analysis, commissioned by the U.S. Department of Energy, of Air Conditioner (AC) efficiency in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative.1 The International Energy Studies group at Lawrence Berkeley National Laboratory in collaboration with Navigant Consulting Inc. performed the analysis. SEAD aims to transform the global market by increasing the penetration of highly efficient equipment and appliances. SEAD partners work together in voluntary activities to: (1) “raise the efficiency ceiling” by pulling superefficient appliances and equipment into the market through cooperation on measures like incentives, procurement, awards, and research and development (R&D) investments; (2) “raise the efficiency floor” by working together to bolster national or regional policies like minimum efficiency standards; and (3) “strengthen the efficiency foundations” of programs by coordinating technical work to support these activities.2 The objective of this analysis is to provide the background technical information necessary to improve the efficiency of ACs and to provide a foundation for the activities of SEAD participating countries. We find that even the best currently available technology offers large efficiency improvement opportunities (35% to 50% reduction in energy consumption from the market average) in most SEAD countries. The cost effective efficiency improvements range from 20% to 30% reduction in energy consumption based on a consumer perspective.

  5. Design of Interline Unified Power Quality Conditioner for Power Quality Disturbances using Simulink

    Science.gov (United States)

    Kumaraswamy, G.; Reddy, Y. Rajasekhar; Harikrishna, Ch.

    2012-10-01

    Proliferation of electronic equipment in commercial and industrial processes has resulted in increasingly sensitive electrical loads to be fed from power distribution system which introduce contamination to voltage and current waveforms at the point of common coupling of industrial loads. The unified power quality conditioner (UPQC) is connected between two different feeders (lines), hence this method of connection of the UPQC is called as Interline UPQC (IUPQC).This paper proposes a new connection for a UPQC to improve the power quality of two feeders in a distribution system. Interline Unified Power Quality Conditioner (IUPQC), specifically aims at the integration of series VSC and Shunt VSC to provide high quality power supply by means of voltage sag/swell compensation, harmonic elimination and power factor correction in a power distribution network, so that improved power quality can be made available at the point of common coupling. The structure, control and capability of the IUPQC are discussed in this paper. The efficiency of the proposed configuration has been verified through simulation using MATLAB/ SIMULINK.

  6. Analysis of a variable speed air conditioner considering the R-290/POE ISO 22 mixture effect

    International Nuclear Information System (INIS)

    Ribeiro, Guilherme B.; Barbosa, Jader R.

    2016-01-01

    Highlights: • A numerical model that considers the oil-refrigerant mixture effect is proposed. • In order to compare the model, an air conditioner calorimeter was constructed. • The system was evaluated under oil circulation ratios between 1 and 7%. • The presence of oil resulted in a significant SEER deterioration (around 69%). - Abstract: Air-conditioning applications using propane (R-290) have several environmental and thermodynamic advantages over more commonly used refrigerants, such as R-410A and R-22. This paper presents the development of a mathematical model for variable capacity air conditioning systems that use R-290/POE ISO 22 as refrigerant/lubricant. The thermodynamic performance of the refrigeration system is evaluated in terms of the SEER (Seasonal Energy Efficiency Ratio). The thermodynamic properties of the refrigerant/lubricant mixture were obtained from a departure-function approach using the Peng-Robinson equation of state. The effect of the oil on the condenser and evaporator heat transfer coefficients and pressure drops was also taken into account. Sub-models were developed for each component of the air conditioning system, including the connecting lines and the scroll compressor. Furthermore, an air conditioner experimental calorimeter was constructed and tested in order to validate the proposed model.

  7. Residential air-conditioner usage in China and efficiency standardization

    International Nuclear Information System (INIS)

    Wu, Jianghong; Liu, Chaopeng; Li, Hongqi; Ouyang, Dong; Cheng, Jianhong; Wang, Yuanxia; You, Shaofang

    2017-01-01

    Determining the real energy consumption and usage pattern of a room air-conditioner (RAC) are important issues from the point of view of both RAC design and evaluation of its energy efficiency. An air-conditioner's running time is fundamental data for the calculation of SEER and APF values. Therefore, in 2010, a nationwide investigation of RAC usage was conducted and 400 selected air-conditioning-units were monitored for a full year to obtain data on their cooling and heating usage. Two running time curves (cooling and heating) were obtained for the air-conditioners as a function of outdoor air temperatures using statistical analysis. The results show that the 27–30 °C temperature range accounts for more than 52% of the cooling time. Conversely, the 0–8 °C temperature range is associated with more than 75% of the heating time. The research presented in this paper has significantly contributed to China's new variable-speed RAC efficiency standard (GB21455-2013). It also has far-reaching implications for both the air-conditioner industry and energy policy in China due to its different method of calculating energy efficiency. - Highlights: • A nationwide survey to realize China's residential air-conditions usage behaviors. • Air-conditioner running time-environment temperature curves are obtained. • The peak heating demand and peak cooling demand happen at 28 °C and 4 °C, respectively. • The temperature of 27 °C–30 °C accounts for over 52% refrigeration time. • The temperature of 0 °C–8 °C occupies more than 75% heating time.

  8. LINES

    Directory of Open Access Journals (Sweden)

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  9. Metallicities of Emission-Line Galaxies from HST ACS PEARS and HST WFC3 ERS Grism Spectroscopy at 0.6 is less than z is less than 2.4

    Science.gov (United States)

    Xia, Lifang; Malhotra, Sangetta; Rhoads, James; Pirzkal, Nor; Straughn, Amber; Finkelstein, Steven; Cohen, Seth; Kuntschner, Harald; Walsh, Jeremy; Windhorst, Rogier A.; hide

    2012-01-01

    Galaxies selected on the basis of their emission line strength. show low metallicities, regardless of their redshifts. We conclude this from a sample of faint galaxies at redshifts between 0.6 optiCa.i with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST) and in the near-infrared using Wide-Field Camera 3 (WFC3). Using a sample of 11 emission line galaxies (ELGs) at 0.6 < z < 2.4 with luminosities of -22 approx < MB approx -19 which have [OII], H-Beta, and [OIII] line flux measurements from the combination of two grism spectral surveys, we use the R23 method to derive the gas-phase oxygen abundances: 7.5 <12+log(0/H)<8.5. The galaxy stellar masses are derived using Bayesian based Markov Chain Monte Carlo (pi MC(exp 2)) fitting of their Spectral Energy Distribution (SED), and span the mass range 8.1 < log(M(stellar)/M(solar)) < 10.1. These galaxies show a mass-metal1icity (M-L) and Luminosity-Metallicity (LZ) relation, which is offset by -line selected galaxies most resemble the local "green peas" galaxies and Lyman-alpha galaxies at z approx = 0.3 and z approx = 2.3 in the M-Z and L-Z relations and their morphologies. The G - M(sub 20) morphology analysis shows that 10 out of 11 show disturbed morphology, even as the star-forming regions are compact. These galaxies may be intrinsically metal poor, being at early stages of formation, or the low metallicities may be due to gas infall and accretion due to mergers.

  10. Peltier ac calorimeter

    OpenAIRE

    Jung, D. H.; Moon, I. K.; Jeong, Y. H.

    2001-01-01

    A new ac calorimeter, utilizing the Peltier effect of a thermocouple junction as an ac power source, is described. This Peltier ac calorimeter allows to measure the absolute value of heat capacity of small solid samples with sub-milligrams of mass. The calorimeter can also be used as a dynamic one with a dynamic range of several decades at low frequencies.

  11. Low Offset AC Correlator.

    Science.gov (United States)

    This patent describes a low offset AC correlator avoids DC offset and low frequency noise by frequency operating the correlation signal so that low...noise, low level AC amplification can be substituted for DC amplification. Subsequently, the high level AC signal is demodulated to a DC level. (Author)

  12. Experimental investigations on performance of liquid desiccant-vapor compression hybrid air conditioner

    International Nuclear Information System (INIS)

    Mohan, B. Shaji; Tiwari, Shaligram; Maiya, M.P.

    2015-01-01

    A coupled desiccant column is integrated with a conventional room air conditioner (AC) to enhance dehumidification of the room air. One desiccant column (absorber) is placed after the evaporator the other (regenerator) after the condenser of the AC unit. Such a novel liquid desiccant vapour compression hybrid air conditioning system has been fabricated and tested in a balanced ambient room type calorimeter for very low flow rates of liquid desiccant (lithium bromide solution). The moisture from the cold supply air is transferred to the hot condenser air by the desiccant flowing in the loop, thereby complimenting the dehumidification of the room air at the evaporator. The supply air is also sensibly heated during the dehumidification process by liquid desiccant in the absorber, which together enables the hybrid system to maintain low humidity in the room. Whereas the liquid desiccant is regenerated by the condenser waste heat, the entire cooling is derived only by the AC unit. The experimental results show that an increase of room temperature reduces both dehumidification of process air and regeneration of liquid desiccant, whereas an increase of room specific humidity enhances both these for the flow rate of the liquid desiccant in the range of 0.2–1.6% of the air flow rate through the absorber. - Highlights: • A liquid desiccant vapor compression hybrid system is fabricated and tested. • The liquid desiccant reduces latent load but equally increases sensible load. • Hybrid system performance is studied for varying room temperature and humidity. • Higher room temperature lowers air dehumidification and desiccant regeneration. • Increase of room specific humidity enhances dehumidification and also regeneration

  13. [Verification of bacteriological safety of PCM 40 air conditioner].

    Science.gov (United States)

    Dumas, J L; Ducel, G; Rouge, J C

    1991-01-01

    This study assessed the bacteriological safety of the bedside air conditioner PCM 40 (Howorth Airtech), used for prevention of intraoperative hypothermia, by blowing filtered warm air through a special mattress. The 3 microns bacterial filter of the device released 2,968 +/- 5,618 particles of diameter less than 3 microns per m3 of room air, containing 78,798 +/- 37,243 of such particles per m3. The amount of bacteries in the air pulsed from the mattress was 30 +/- 41 cfu/m3 vs 120 cfu/m3 in the ambient air and in the hot air supply tubing it reached 6 +/- 5 cfu/m3 vs 175 +/- 77 cfu/m3. It is concluded that bacteriological data do not contra-indicate the use of this air conditioner in the operating theater. The only limitations for use are the position (prone or lateral position) and type of surgery (neurosurgery).

  14. Effect of conditioner load on the polishing pad surface during chemical mechanical planarization process

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheol Min; Qin, Hong Yi; Hong, Seok Jun; Jeon, Sang Hyuk; Kulkarni, Atul; Kim, Tae Sun [Sungkyunkwan University, Suwon (Korea, Republic of)

    2016-12-15

    During the Chemical mechanical planarization (CMP), the pad conditioning process can affect the pad surface characteristics. Among many CMP process parameters, the improper applied load on the conditioner arm may have adverse effects on the polyurethane pad. In this work, we evaluated the pad surface properties under the various conditioner arm applied during pad conditioning process. The conditioning pads were evaluated for surface topography, surface roughness parameters such as Rt and Rvk and Material removal rate (MRR) and within-wafer non-uniformity after wafer polishing. We observed that, the pad asperities were collapsed in the direction of conditioner rotation and blocks the pad pores applied conditioner load. The Rvk value and MRR were founded to be in relation with 4 > 1 > 7 kgF conditioner load. Hence, this study shows that, 4 kgF applied load by conditioner is most suitable for the pad conditioning during CMP.

  15. Viewpoint Mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia

    International Nuclear Information System (INIS)

    Mahlia, T.M.I.; Masjuki, H.H.; Saidur, R.; Amalina, M.A.

    2004-01-01

    Malaysian economy has grown rapidly in the last two decades. This growth has increased the ownership of household electrical appliances including room air conditioners. The number of users of air conditioners is predicted to grow dramatically in Malaysian households in the future. To reduce energy consumption in the residential sector, the Malaysia Energy Commission is considering implementing minimum energy efficiency standards for room air conditioners in early 2004. This paper attempts to predict the potential mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia. The calculations were based on the growth of room air conditioners ownership data in Malaysian households. The study found that the energy efficiency standards for room air conditioners would mitigate a significant amount of emissions in this country

  16. Active Participation of Air Conditioners in Power System Frequency Control Considering Users’ Thermal Comfort

    Directory of Open Access Journals (Sweden)

    Rongxiang Zhang

    2015-09-01

    Full Text Available Air conditioners have great potential to participate in power system frequency control. This paper proposes a control strategy to facilitate the active participation of air conditioners. For each air conditioner, a decentralized control law is designed to adjust its temperature set point in response to the system frequency deviation. The decentralized control law accounts for the user’s thermal comfort that is evaluated by a fuzzy algorithm. The aggregation of air conditioners’ response is conducted by using the Monte Carlo simulation method. A structure preserving model is applied to the multi-bus power system, in which air conditioners are aggregated at certain load buses. An inner-outer iteration scheme is adopted to solve power system dynamics. An experiment is conducted on a test air conditioner to examine the performance of the proposed decentralized control law. Simulation results on a test power system verify the effectiveness of the proposed strategy for air conditioners participating in frequency control.

  17. Research on a Micro-Grid Frequency Modulation Strategy Based on Optimal Utilization of Air Conditioners

    Directory of Open Access Journals (Sweden)

    Qingzhu Wan

    2016-12-01

    Full Text Available With the proportion of air conditioners increasing gradually, they can provide a certain amount of frequency-controlled reserves for a micro-grid. Optimizing utilization of air conditioners and considering load response characteristics and customer comfort, the frequency adjustment model is a quadratic function model between the trigger temperature of the air conditioner compressor, and frequency variation is provided, which can be used to regulate the trigger temperature of the air conditioner when the micro-grid frequency rises and falls. This frequency adjustment model combines a primary frequency modulation method and a secondary frequency modulation method of the energy storage system, in order to optimize the frequency of a micro-grid. The simulation results show that the frequency modulation strategy for air conditioners can effectively improve the frequency modulation ability of air conditioners and frequency modulation effects of a micro-grid in coordination with an energy storage system.

  18. Development of a solar-powered residential air conditioner

    Science.gov (United States)

    1975-01-01

    The initial objective of the program was the optimization (in terms of cost and performance) of a Rankine cycle mechanical refrigeration system which utilizes thermal energy from a flat solar collector for air conditioning residential buildings. However, feasibility investigations of the adsorption process revealed that a dessicant-type air conditioner offers many significant advantages. As a result, limited efforts were expended toward the optimization of such a system.

  19. Room air conditioner load control under summer comfort constraint

    OpenAIRE

    Da Silva , David; Brancaccio , M; Duplessis , Bruno; Adnot , J

    2010-01-01

    International audience; Load control options interest is growing because it can represent a response to future network investments and to congestion problems. In this frame, the present paper gives a methodology to quantify the value of load control for heat pumps (room air conditioners), in small tertiary and residential buildings, considering the occupant's comfort and the electrical grid needs for load shift. This methodology was applied to a small office building where simulations were ma...

  20. Ventilation-air conditioner system in nuclear power plant

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Sugisaki, Toshihiko.

    1989-01-01

    This invention concerns a ventilation-air conditioner system which enables, upon occurrence of accidents in a nuclear power plant, continuous operation for other adjacent nuclear power plants with no effect of accidents. Air supply system and exhaust system are operated during usual operaiton. If loss of coolants accidents should occur in an adjacent nuclear power plants, operation is switched from ventilation operaiton to the operation of re-cycling system based on an AND logic of three signals, that is, a pressure HIGH signal for the reactor container, a water level LOW signal for the reactor and a radioactivity signal of the ventilation-air conditioner sytem on the side of air supply in the nuclear power plant. Thus, nuclear reactor buildings of the nuclear power plant are from the external atmosphere. Therefore, the radioactivity HIGH signal for switching to the emergency air conditioner system of the nuclear power plant is not actuated due to the loss of coolant accidents in the adjacent nuclear power plant. In addition, since the atmospheric temperature in the nuclear reactor building can be maintained by a cooling device disposed to the recycling system, reactor shutdown can be prevented. (I.S.)

  1. Inverted Unified Power Quality Conditioner to compensate overvoltage

    Directory of Open Access Journals (Sweden)

    Yeison Alberto Garcés Gómez

    2017-07-01

    Full Text Available Introduction: The use of unified power quality conditioners UPQC in the electric systems can correct waveform distortions in a steady state, like harmonics, flicker, and the power factor. Objective: This paper presents a novel approach for active compensation of overvoltage with a UPQC in dual topology or iUPQC. Methodology: The study it is presented in five stages, the section I shows an introduction and the state of the art, section II presents the unified power quality conditioner UPQC, section III describes the generalized reactive power theory applied to the iUPQC (dual topology, section IV shows the numerical simulations and the results and section V presents the conclusions of the study. Results: The results for the application of the iUPQC to the compensation of overvoltage are proved and compared with the more representative theory related to compensation of harmonics and low power factor. Conclusions: The control algorithm presented for the unified power quality conditioner in dual topology allows to compensate the overvoltage in three-phase systems as well as voltage and current harmonics and the low power factor.

  2. Development of multiplexing network for air conditioner systems; Eakon yo LAN system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, T; Nakazawa, Y; Nakase, M; Sato, Y [Nissan Motor Co. Ltd., Tokyo (Japan); Nomura, M; Okasato, Y; Sunaga, H [Calsonic Corp., Tokyo (Japan)

    1997-10-01

    Plural air flap actuators of the air conditioner system in a vehicle have been integrated into a single-type actuator using two newly developed technologies: super-low-cost multiplexing network technology and digital motor control technology with a 1-bit A/D converter. The number of harnesses and connectors and the handling load of the air conditioner control microcomputer are reduced, so that we succeeded in sharply reducing the cost of the air conditioner system. 9 figs., 2 tabs.

  3. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Diddi, Saurabh [Government of India, New Delhi (India). Bureau of Energy Efficiency; Ahuja, Deepanshu [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Mukherjee, P. K. [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Walia, Archana [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States)

    2016-06-30

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. We assess several efficiency levels, two of which are summarized below in the report. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one star level) should be evaluated rigorously considering significant benefits to consumers, energy security and environment.

  4. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Diddi, Saurabh [Bureau of Energy Efficiency, Government of India (India); Ahuja, Deepanshu [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Mukherjee, P. K. [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Walia, Archana [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States)

    2016-06-01

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant,and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one-star level) should be evaluated rigorously considering significant benefits to consumers, energy security, and environment

  5. Superconductive AC current limiter

    International Nuclear Information System (INIS)

    Bekhaled, M.

    1987-01-01

    This patent describes an AC current limiter for a power transport line including a power supply circuit and feeding a load circuit via an overload circuit-breaker member. The limiter comprises a transformer having a primary winding connected in series between the power supply circuit and the load circuit and at least one secondary winding of superconductor material contained in a cryogenic enclosure and short-circuited on itself. The leakage reactance of the transformer as seen from the primary winding is low, and the resistance of the at least one secondary winding when in the non-superconducting state and as seen from the primary is much greater than the nominal impedance of the transformer. The improvement whereby the at least one secondary winding of the transformer comprises an active winding in association with a set of auxiliary windings. The set of auxiliary windings is constituted by an even number of series-connected auxiliary windings wound in opposite directions, with the total number of turns in one direction being equal to the total number of turns in the opposite direction, and with the thermal capacity of the secondary winding as a whole being sufficiently high to limit the expansion thereof to a value which remains small during the time it takes the circuit-breaking member to operate

  6. Determination of heavy metals in air conditioner dust using FAAS and INAA

    International Nuclear Information System (INIS)

    Siddique, N.

    2012-01-01

    The elements Cd, Cr, Cu, Mn, Ni, Pb and Zn were determined in dust samples collected from air conditioner (AC) filters from 15 commercial sites of Lahore using flame atomic absorption spectroscopy (FAAS). The elements Cr, Mn and Zn were also determined using instrumental neutron activation analysis (INAA). The results obtained showed that higher amounts of these metals were measured in these dust samples than normally found in soil. This was especially true for Cd, Cu, Pb and Zn. Generally the amounts of Cd, Cr and Mn did not vary throughout the city of Lahore but the amounts of the traffic related Cu, Pb and Zn elements had the more variable ranges of 30-140, 30-230 and 74-2810 mg/kg respectively. The concentrations obtained for Cr, Mn and Zn by INAA were found to be higher than those obtained using FAAS. Analysis of the data obtained showed the digestion procedure employed to be the possible cause for this occurrence. It was also found that Mn was being over-estimated by INAA due to the interference from the Mg peak. (author)

  7. Penggunaan Air Conditioner sebagai Aspek Pencegahan terhadap Kerusakan Bahan Pustaka

    Directory of Open Access Journals (Sweden)

    Irvan Muliyadi

    2013-12-01

    Full Text Available Penggunaan AC di perpustakaan dapat mengurangi kerusakan buku dan manuskrip yang disebabkan oleh panas. Secara praktis AC dapat mengontrol temperatur dan kelembaban serta membersihkan udara. Ada 4 fungsi dari AC yaitu fentilasi, filterasi, pengontrolan temperatur, dan pengontrolan kelembaban.

  8. FLUIDIC AC AMPLIFIERS.

    Science.gov (United States)

    Several fluidic tuned AC Amplifiers were designed and tested. Interstage tuning and feedback designs are considered. Good results were obtained...corresponding Q’s as high as 12. Element designs and test results of one, two, and three stage amplifiers are presented. AC Modulated Carrier Systems

  9. Evaluation of environmental and physiological factors of a whole ceiling-type air conditioner using a salivary biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yusuke; Yamaguchi, Masaki [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Morito, Naomi; Nishimiya, Hajime; Yamagishi, Hideyuki [Asahi Kasei Homes Corporation, R and D Laboratories, 2-1 Samejima, Fuji, Shizuoka 416-8501 (Japan)

    2009-06-15

    In order to improve environmental condition such as humidity and airflow in living spaces, a whole ceiling-type air conditioner is proposed. This novel air conditioner exhaust dispersed airflow from the whole ceiling by using a 3-dimensional knit fabric. The purpose of this paper is to reveal the effects when controlling humidity and airflow using the whole ceiling-type air conditioner compared to a commercialized concentrated exhaust air conditioner (normal-type air conditioner) under the same temperature. Salivary {alpha}-amylase activity (SAA) was used as an index of sympathetic nervous activity. An acute experiment for a 15 min period was conducted using 12 healthy young female adults. No significant differences in room and skin temperatures were observed between the whole ceiling-type air conditioner and the normal-type air conditioner. The whole ceiling-type air conditioner showed 11.1% lower humidity than the normal-type air conditioner. The whole ceiling-type air conditioner showed one-thirteenth the airflow of the normal-type air conditioner. As a result, the PMV of the whole ceiling-type air conditioner was more comfortable level than the normal one. Moreover, subjective evaluation questionnaire revealed a significant difference was observed in wind perception (windy). The SAA of subjects under the whole ceiling-type air conditioner showed significantly low values compared with the normal-type air conditioner. It was found that the subject's sympathetic nervous activity has been inactivated under the conditions of the whole ceiling-type air conditioner. Thus, it was revealed that the whole ceiling-type air conditioner provides a more comfortable air environment by reducing physical stimulations to humans. (author)

  10. AC power supply systems

    International Nuclear Information System (INIS)

    Law, H.

    1987-01-01

    An ac power supply system includes a rectifier fed by a normal ac supply, and an inverter connected to the rectifier by a dc link, the inverter being effective to invert the dc output of the receiver at a required frequency to provide an ac output. A dc backup power supply of lower voltage than the normal dc output of the rectifier is connected across the dc link such that the ac output of the rectifier is derived from the backup supply if the voltage of the output of the inverter falls below that of the backup supply. The dc backup power may be derived from a backup ac supply. Use in pumping coolant in nuclear reactor is envisaged. (author)

  11. 16 CFR Appendix I to Part 305 - Heating Performance and Cost for Central Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... RULEâ) Pt. 305, App. I Appendix I to Part 305—Heating Performance and Cost for Central Air Conditioners... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Heating Performance and Cost for Central Air Conditioners I Appendix I to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC...

  12. Bacterial community structures in air conditioners installed in Japanese residential buildings.

    Science.gov (United States)

    Hatayama, Kouta; Oikawa, Yurika; Ito, Hiroyuki

    2018-01-01

    The bacterial community structures in four Japanese split-type air conditioners were analyzed using a next-generation sequencer. A variety of bacteria were detected in the air filter of an air conditioner installed on the first floor. In the evaporator of this air conditioner, bacteria belonging to the genus Methylobacterium, or the family of Sphingomonadaceae, were predominantly detected. On the other hand, the majority of bacteria detected in the air filters and evaporators of air conditioners installed on the fifth and twelfth floors belonged to the family Enterobacteriaceae. The source of bacteria belonging to the family Enterobacteriaceae may have been aerosols generated by toilet flushing in the buildings. Our results suggested the possibility that the bacterial contamination in the air conditioners was affected by the floor level on which they were installed. The air conditioner installed on the lower floor, near the ground, may have been contaminated by a variety of outdoor bacteria, whereas the air conditioners installed on floors more distant from the ground may have been less contaminated by outdoor bacteria. However, these suppositions may apply only to the specific split-type air conditioners that we analyzed, because our sample size was small.

  13. 16 CFR Appendix H to Part 305 - Cooling Performance and Cost for Central Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... RULEâ) Pt. 305, App. H Appendix H to Part 305—Cooling Performance and Cost for Central Air Conditioners... Split System Units Central Air Conditioners (Cooling Only): All capacities 10.9 23.0 Heat Pumps (Cooling... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Cooling Performance and Cost for Central Air...

  14. Locally produced natural conditioners for dewatering of faecal sludge.

    Science.gov (United States)

    Gold, Moritz; Dayer, Pauline; Faye, Marie Christine Amie Sene; Clair, Guillaume; Seck, Alsane; Niang, Seydou; Morgenroth, Eberhard; Strande, Linda

    2016-11-01

    In urban areas of low-income countries, treatment of faecal sludge (FS) is insufficient or non-existent. This results in large amounts of FS being dumped into the environment. Existing treatment technologies for FS, such as settling-thickening tanks and drying beds, are land intensive which is limiting in urban areas. Enhanced settling and dewatering by conditioning was evaluated in order to reduce the treatment footprint (or increase treatment capacity). Conventional wastewater conditioners, such as commercially available lime and polymers, are expensive, and commonly rely on complex supply chains for use in low-income countries. Therefore, the treatment performance of five conditioners which could be produced locally was evaluated: Moringa oleifera seeds and press cake, Jatropha curcas seeds, Jatropha Calotropis leaves and chitosan. M. oleifera seeds and press cake, and chitosan improved settling and dewatering and had a similar performance compared to lime and polymers. Optimal dosages were 400-500 kg M. oleifera/t TS, 300-800 kg lime/t TS and 25-50 kg polymer solution/t TS. In comparison, chitosan required 1.5-3.75 kg/t TS. These dosages are comparable to those recommended for wastewater (sludge). The results indicate that conditioning of FS can reduce total suspended solids (TSS) in the effluent of settling-thickening tanks by 22-81% and reduce dewatering time with drying beds by 59-97%. This means that the area of drying beds could be reduced by 59-97% with end-use as soil conditioner, or 9-26% as solid fuel. Least expensive options and availability will depend on the local context. In Dakar, Senegal, chitosan produced from shrimp waste appears to be most promising.

  15. Capacity modulation of an inverter-driven multi-air conditioner using electronic expansion valves

    International Nuclear Information System (INIS)

    Choi, J.M.; Kim, Y.C.

    2003-01-01

    An inverter-driven multi-air conditioner provides the benefits of comfort, energy conservation and easy maintenance. Recently, the multi-air conditioner has been employed in small and medium-sized buildings. However, the performance data and control algorithm for multi-air conditioners are limited in literature due to complicated system parameters and operating conditions. In the present study, the performance of an inverter-driven multi-air conditioner having two indoor units with electronic expansion valves (EEV) was measured by varying indoor loads, EEV opening, and compressor speed. Based on the experimental results, the operating characteristics and capacity modulation of the inverter-driven multi-air conditioner are discussed. As a result, it is suggested that the superheats for both indoor units have to be maintained around 4 o C by utilizing the EEVs in this system, and consequently, the compressor speed needs to be adjusted to provide optimum cooling capacity for each indoor unit

  16. Improving Power Quality in AC Supply Grids

    Directory of Open Access Journals (Sweden)

    Piotr Fabijański

    2015-12-01

    Full Text Available This paper describes a digital and actual model of the UPQC (Unified Power Quality Conditioner integrated system for power quality improvement. The UPQC’s design and its connection to an AC supply grid, 1-phase and 3-phase alike, provide effective compensation of unwanted interferences in the waveforms of load supply voltages and non-linear load currents. This article presents an overview of topologies and control strategies. The study of the UPQC confirmed its positive impact on the power quality. The electricity parameters were significantly improved. Total harmonic distortion in supply voltage THDu decreased six-fold to 1.89%, and total harmonic distortion in load current THDi decreased more than ten-fold to 2.38% for a non-linear load (uncontrolled bridge rectifier with load L. Additionally, symmetrisation of supply voltages and reactive power compensation Q of linear load was obtained. The UPQC integrated system for power quality improvement can be used wherever high-quality and PN-EN 50160 standard – compliant electricity is required.

  17. ACS Zero Point Verification

    Science.gov (United States)

    Dolphin, Andrew

    2005-07-01

    The uncertainties in the photometric zero points create a fundamental limit to the accuracy of photometry. The current state of the ACS calibration is surprisingly poor, with zero point uncertainties of 0.03 magnitudes. The reason for this is that the ACS calibrations are based primarily on semi-emprical synthetic zero points and observations of fields too crowded for accurate ground-based photometry. I propose to remedy this problem by obtaining ACS images of the omega Cen standard field with all nine broadband ACS/WFC filters. This will permit the direct determination of the ACS zero points by comparison with excellent ground-based photometry, and should reduce their uncertainties to less than 0.01 magnitudes. A second benefit is that it will facilitate the comparison of the WFPC2 and ACS photometric systems, which will be important as WFPC2 is phased out and ACS becomes HST's primary imager. Finally, three of the filters will be repeated from my Cycle 12 observations, allowing for a measurement of any change in sensitivity.

  18. Research on a compact adsorption room air conditioner

    International Nuclear Information System (INIS)

    Yang, G.Z.; Xia, Z.Z.; Wang, R.Z.; Keletigui, Daou; Wang, D.C.; Dong, Z.H.; Yang, X.

    2006-01-01

    A novel compact adsorption room air conditioner with a cooling capacity of 1 kW has been designed, and two prototypes have been built. A two bed, continuous adsorption refrigeration cycle with heat recovery and mass recovery is adopted. Micropore spherical silica gel and water are selected as the working pair. A gravity heat pipe with methanol as working medium is designed to output the cooling. Experimental investigations have indicated that under typical air conditioning conditions, for the first prototype, a cooling capacity of 687 W and a COP (coefficient of performance) of 0.307 can be obtained. However, for the improved one, a cooling capacity of 790 W and a COP of 0.446 can be reached. It is also proved that the operating temperatures have strong influences on the performance. The designed room air conditioner can be driven by a low grade heat source ( o C) and has small dimensions of 300 mm (depth), 500 mm (width) and 950 mm (height)

  19. Huffing air conditioner fluid: a cool way to die?

    Science.gov (United States)

    Phatak, Darshan R; Walterscheid, Jeffrey

    2012-03-01

    "Huffing," the form of substance abuse involving inhalants, is growing in popularity because of the ease and availability of chemical inhalants in many household products. The purpose in huffing is to achieve euphoria when the chemicals in question interact with the central nervous system in combination with oxygen displacement. The abuser is lulled into a false sense of safety despite the well-documented potential for lethal cardiac arrhythmia and the effects of chronic inhalant abuse, including multisystem organ failure, and brain damage. Huffing air conditioner fluid is a growing problem given the accessibility to outdoor units and their fluid components, such as difluorochloromethane(chlorodifluoromethane, Freon), and we have classified multiple cases of accidental death due to the toxicity of difluorochloromethane. Given the ubiquity of these devices and the vast lack of gating or security devices, they make an inviting target for inhalant abusers. Acute huffing fatalities have distinct findings that are present at the scene, given the position of the decedent and proximity to the air conditioner unit. The purpose of the autopsy in these cases is to exclude other potential causes of death and to procure specimens for toxicological analysis.

  20. Shampoo and Conditioners: What a Dermatologist Should Know?

    Science.gov (United States)

    D'Souza, Paschal; Rathi, Sanjay K

    2015-01-01

    Dermatologists many a times encounter questions from patients and even colleagues asking about how to keep their hair looking clean, healthy and beautiful. Therefore, familiarity and a basic knowledge of the available hair care products will help them to guide their patients properly. A shampoo not only provides the cleaning of the scalp skin and hair as its primary function, but in addition also serves to condition and beautify hair and acts as an adjunct in the management of various scalp disorders. To achieve this, various ingredients in the correct proportion are mixed to provide a shampoo which is suitable for individuals having different hair types and hair need. Among the ingredients that go into the making of a shampoo are detergents, conditioners, thickeners, sequestering agents, pH adjusters, preservatives and specialty additives. Hair conditioners are designed to improve hair manageability, decrease hair static electricity and add luster. They are used in several ways depending upon the state of hair and requirement of the individual. This article attempts to put forward the basic and practical aspects regarding use of these products.

  1. Shampoo and conditioners: What a dermatologist should know?

    Directory of Open Access Journals (Sweden)

    Paschal D′Souza

    2015-01-01

    Full Text Available Dermatologists many a times encounter questions from patients and even colleagues asking about how to keep their hair looking clean, healthy and beautiful. Therefore, familiarity and a basic knowledge of the available hair care products will help them to guide their patients properly. A shampoo not only provides the cleaning of the scalp skin and hair as its primary function, but in addition also serves to condition and beautify hair and acts as an adjunct in the management of various scalp disorders. To achieve this, various ingredients in the correct proportion are mixed to provide a shampoo which is suitable for individuals having different hair types and hair need. Among the ingredients that go into the making of a shampoo are detergents, conditioners, thickeners, sequestering agents, pH adjusters, preservatives and specialty additives. Hair conditioners are designed to improve hair manageability, decrease hair static electricity and add luster. They are used in several ways depending upon the state of hair and requirement of the individual. This article attempts to put forward the basic and practical aspects regarding use of these products.

  2. AcMNPV

    African Journals Online (AJOL)

    USER

    2010-08-16

    Aug 16, 2010 ... biosynthesis pathway and plays an important role in insect growth and .... Construction and propagation of recombined AcMNPV. The recombined ... infected by virus increased with incubation time (Figure. 3). The growth of ...

  3. AC BREAKDOWN IN GASES

    Science.gov (United States)

    electron- emission (multipactor) region, and (3) the low-frequency region. The breakdown mechanism in each of these regions is explained. An extensive bibliography on AC breakdown in gases is included.

  4. THERMIONIC AC GENERATION

    Science.gov (United States)

    is shown that the maximum ac efficiency is equal to approximately 70% of the corresponding dc value. An illustrative example, including a proposed design for a rather unconventional transformer, is appended. (Author)

  5. Need Analysis for Air Conditioners in Public Sector of Surabaya City Government

    Directory of Open Access Journals (Sweden)

    Dwiarti Larasputri

    2017-01-01

    Full Text Available In typical buildings, air conditioners have the biggest percentage in energy consumption among all sectors. It makes a good management for air conditioners is needed and important in order to use the energy efficiently. Having a very hot and humid weather, it gives impact that most of buildings in Surabaya installed air conditioners, including Surabaya City Government office buildings. However, there is no regulation nor guidance how to manage air conditioners in Surabaya City Government, while Surabaya itself has a goal to become a green-eco city. Then, the existing condition of air conditioners usage in Surabaya Government units (SKPDs is evaluated. The evaluation resulted that most of air conditioners were over capacity and not all of them were efficient in energy consumption. Therefore, a need analysis is required to help Surabaya City Government managing its air conditioners better. By applying two different concepts, one is based on the architectural view and another one is based on green building criteria, the existing condition is analyzed and two procedures of need analysis are produced. The procedures can be implemented for two different conditions of office building rooms in Surabaya City Government.

  6. Influence of local air velocity from air conditioner evaluated by salivary and skin biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Masaki; Takahashi, Takayuki; Yoshino, Yuichiro; Sasaki, Makoto [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Nishimiya, Hajime [Asahi Kasei Homes Corporation, R and D Laboratories, 2-1 Samejima, Fuji, Shizuoka 416-8501 (Japan)

    2010-11-15

    The purpose of this paper is to reveal both the psychosomatic and the physical effects of local air velocity from an air conditioner using biomarkers which can be collected noninvasively. Salivary {alpha}-amylase activity (SAA) and salivary cortisol were used as the indexes of psychosomatic effects. The total protein (TP) collected from stratum corneum was used as an index of the physical condition of dry skin. A continuous experiment over a 5 days period in summer was conducted using 8 healthy young male adults for 2-types of airflow conditioners, a whole ceiling-type air conditioner (without local air velocity) and a normal-type air conditioner (with local air velocity). The subjects felt cool, windy, dry and uncomfortable when under the normal-type air conditioner as determined in a subjective evaluation. The SAA under the normal-type air conditioner fluctuated more widely than with the whole ceiling-type air conditioner. The level of salivary cortisol decreased more in a day under the normal-type air conditioner than with the whole ceiling-type air conditioner. These results showed that reducing local air velocity may provide more healthy psychosomatic conditions over the long-term. Moreover, the TP of a drying-exposed skin area showed a significant change during this experiment whereas the TP of drying-protected area was relatively unchanged. It was indicated that one week's exposure to local air velocity conditions possibly influences the drying of facial skin. Thus, air movement at low velocity can be provides more comfortable conditions not only psychosomatically but also physically. (author)

  7. Current Evaluation Procedures for Fertilizers and Soil Conditioners Used in Organic Agriculture. Proceedings of a workshop held April 29–30, 2004 at Emerson College, Great Britain

    OpenAIRE

    Canali, Stefano; Stopes, Christopher; Schmid, Otto; Speiser, Bernhard

    2005-01-01

    Table of Contents Fertilizers and soil conditioners in organic farming in Austria Alexandra Hozzank and Wilfried Hartl Fertilizers and soil conditioners in organic farming in the Czech Republic Anamarija Slabe Fertilizers and soil conditioners in organic farming in Denmark Rasmus Ørnberg Eriksen and Erik Steen Kristensen Fertilizers and soil conditioners in organic farming in France Marie-Christine Monnier Fertilizers and soil conditioners in organic fa...

  8. Air conditioner with three stages of indirect regeneration

    International Nuclear Information System (INIS)

    Worthington, M.N.

    1987-01-01

    An air conditioner is described comprising: a cabinet defining an internal evaporation chamber and having an air inlet and an air outlet; a heat exchanger mounted in the cabinet and defining an air movement path between the air inlet and the air outlet; means for supplying air to be cooled to the air inlet of the cabinet of movement through the air movement path of the heat exchanger in a heat exchanger relationship; air diversion means for continuously diverting some of the air emerging from the air outlet of the cabinet; and means in the evaporation chamber of the cabinet for recirculating spraying water into the chiller tube of the heat exchanger for interacting with the diverted air moving therethrough to evaporatively cool the heat exchanger

  9. Development of a solar powered residential air conditioner (General optimization)

    Science.gov (United States)

    Lowen, D. J.

    1976-01-01

    A commercially available 3-ton residential Lithium Bromide (LiBr) absorption air conditioner was modified for use with lower temperature solar heated water. The modification included removal of components such as the generator, concentration control chamber, liquid trap, and separator; and the addition of a Chrysler designed generator, an off-the-shelf LiBr-solution pump. The design goal of the modified unit was to operate with water as the heat-transfer fluid at a target temperature of 85 C (185 F), 29.4 C (85 F) cooling water inlet, producing 10.5 kW (3 tons) of cooling. Tests were performed on the system before and after modification to provide comparative data. At elevated temperatures (96 C, 205 F), the test results show that Lithium Bromide was carried into the condenser due to the extremely violent boiling and degraded the evaporator performance.

  10. Computational analysis of the flow field downstream of flow conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Erdal, Asbjoern

    1997-12-31

    Technological innovations are essential for maintaining the competitiveness for the gas companies and here metering technology is one important area. This thesis shows that computational fluid dynamic techniques can be a valuable tool for examination of several parameters that may affect the performance of a flow conditioner (FC). Previous design methods, such as screen theory, could not provide fundamental understanding of how a FC works. The thesis shows, among other things, that the flow pattern through a complex geometry, like a 19-hole plate FC, can be simulated with good accuracy by a k-{epsilon} turbulence model. The calculations illuminate how variations in pressure drop, overall porosity, grading of porosity across the cross-section and the number of holes affects the performance of FCs. These questions have been studied experimentally by researchers for a long time. Now an understanding of the important mechanisms behind efficient FCs emerges from the predictions. 179 ref., 110 figs., 8 tabs.

  11. Radio decontamination of hair conditioner for capillary ammniotherapy

    International Nuclear Information System (INIS)

    Romay, Z.; Otero, I.; Chavez, A.; Torriente, I.

    1996-01-01

    The Hair conditioner, which belongs to the group of cosmetic products Dr Miyares Cao, was artificially contaminated, kept at different values of temperature (-20 oC , 0 oC and +20 oC ) and irradiated to different doses (6, 10, 12, 15, 20, 25 and 30 kGy) and 25 oC for studying the effect of gamma radiation on it and the possibility of use of this technology for its decontamination. The radiobiological parameters of the contaminator and the quality of irradiated products were determined. Was conclude that the product maintain its organolepthics characteristics and others quality parameters after irradiated to 20 kGy and +20 oC of temperature before irradiation. Finally, the decontamination of studied product was obtained by means its irradiation to 16.2 kGy

  12. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece.

    Science.gov (United States)

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-05-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑21PBDE) in A/C dust ranged between 84 and 4062 ng g(-1) with a median value of 1092 ng g(-1), while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day(-1) (median 12 ng day(-1)). Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner...

  14. Development of a solar-powered residential air conditioner: System optimization preliminary specification

    Science.gov (United States)

    Rousseau, J.; Hwang, K. C.

    1975-01-01

    Investigations aimed at the optimization of a baseline Rankine cycle solar powered air conditioner and the development of a preliminary system specification were conducted. Efforts encompassed the following: (1) investigations of the use of recuperators/regenerators to enhance the performance of the baseline system, (2) development of an off-design computer program for system performance prediction, (3) optimization of the turbocompressor design to cover a broad range of conditions and permit operation at low heat source water temperatures, (4) generation of parametric data describing system performance (COP and capacity), (5) development and evaluation of candidate system augmentation concepts and selection of the optimum approach, (6) generation of auxiliary power requirement data, (7) development of a complete solar collector-thermal storage-air conditioner computer program, (8) evaluation of the baseline Rankine air conditioner over a five day period simulating the NASA solar house operation, and (9) evaluation of the air conditioner as a heat pump.

  15. DEMONSTRATION AND TESTING OF AN EER OPTIMIZER SYSTEM FOR DX AIR-CONDITIONERS

    Science.gov (United States)

    2017-10-07

    Conditioner and Any Web Connected Device Such as a Tablet, Phone, Laptop, or Desktop Computer. ............. 28  Figure 15. A Summary Screen Showing...efficiency specifications published by the Consortium for Energy Efficiency (CEEE) for new unitary air conditioning and heat pump systems5 establish Energy...Figure 14. Connection Diagram Showing Data Path between the Air Conditioner and Any Web Connected Device Such as a Tablet, Phone, Laptop, or Desktop

  16. Energy and economic analysis of a building air-conditioner with a phase change material (PCM)

    International Nuclear Information System (INIS)

    Chaiyat, Nattaporn

    2015-01-01

    Highlights: • Phase change material of Rubitherm20 was applied with the air-conditioner under the climate of Thailand. • PCM was used to reduce cooling load and electrical power of the air-conditioner. • Mathematical model of the packed ball bed of PCM was presented to predict the thermal performance. - Abstract: In this study, a concept of using phase change material (PCM) for improving cooling efficiency of an air-conditioner had been presented under Thailand climate. Rubitherm20 (RT-20) was selected to evaluate the thermal performance by reducing the air temperature entering the evaporating coil. The model of PCM celluloid balls had been performed with the air-conditioner. For the experiment, 2 TR of R-134a air-conditioner was chosen to test a pack bed of PCM balls with thickness 40 cm. The pressure drops of the air flowing through the bed were considered with and without a set of by-pass tubes along the height of the storage bed. The mathematical model of the air-conditioner with the PCM storage was developed and verified with the testing results. From the study results, it could be seen that pressure drops of the bed with and without bypass tubes were nearly the same results. Thus, PCM ball pack bed using RT-20 without bypass tubes was used to improve the cooling efficiency of the air-conditioner. The experimental result of the modified unit was compared and verified with the mathematical model, which agreed quite well with the simulation result. Finally, the model was used to analyze the economic result, which found that the electrical consumption of the modified air-conditioner could be decreased around 3.09 kW h/d. The saving cost from the PCM bed could be 9.10% of 170.03 USD/y and the payback period was around 4.15 y

  17. Mass of AC Andromedae

    International Nuclear Information System (INIS)

    King, D.S.; Cox, A.N.; Hodson, S.W.

    1975-01-01

    Calculations indicate that AC Andromedae is population I rather than population II. A mass and radius for this star are calculated using a new set of opacities for the Kippenhahn Ia mixture. It is concluded that the mass is too high for an ordinary RR Lyrae star. (BJG)

  18. AC/RF Superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Ciovati, G [Jefferson Lab (United States)

    2014-07-01

    This contribution provides a brief introduction to AC/RF superconductivity, with an emphasis on application to accelerators. The topics covered include the surface impedance of normal conductors and superconductors, the residual resistance, the field dependence of the surface resistance, and the superheating field.

  19. AC/RF Superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Ciovati, Gianluigi [JLAB

    2015-02-01

    This contribution provides a brief introduction to AC/RF superconductivity, with an emphasis on application to accelerators. The topics covered include the surface impedance of normal conductors and superconductors, the residual resistance, the field dependence of the surface resistance, and the superheating field.

  20. Improvement of Cooling Performance of a Compact Thermoelectric Air Conditioner Using a Direct Evaporative Cooling System

    Science.gov (United States)

    Tipsaenporm, W.; Lertsatitthanakorn, C.; Bubphachot, B.; Rungsiyopas, M.; Soponronnarit, S.

    2012-06-01

    This paper presents the results of tests carried out to investigate the potential application of a direct evaporative cooling (DEC) system for improving the performance of a compact thermoelectric (TE) air conditioner. The compact TE air conditioner is composed of three TE modules. The cold and hot sides of the TE modules were fixed to rectangular fin heat sinks. The DEC system produced cooling air that was used to assist the release of heat from the heat sinks at the hot side of the TE modules. The results showed that the cooling air dry bulb temperature from the DEC system achieved drops of about 5.9°C in parallel with about a 33.4% rise in relative humidity. The cooling efficiency of the DEC system varies between 72.1% and 81.5%. It increases the cooling capacity of the compact TE air conditioner from 53.0 W to 74.5 W. The 21.5 W (40.6%) increase represents the difference between the compact air conditioner operating with ambient air flowing through the TE module's heat sinks, and the compact air conditioner operating with the cooler air from the DEC system flowing through the TE module's heat sinks. In both scenarios, electric current of 4.5 A was supplied to the TE modules. It also has been experimentally proven that the coefficient of performance (COP) of the compact TE air conditioner can be improved by up to 20.9% by incorporating the DEC system.

  1. Application of evaporative cooling on the condenser of window-air-conditioner

    International Nuclear Information System (INIS)

    Hajidavalloo, Ebrahim

    2007-01-01

    Reduction of energy consumption is a major concern in the vapor compression refrigeration cycle especially in the area with very hot weather conditions (about 50 deg. C), where window-air-conditioners are usually used to cool homes. In this weather condition performance of air condenser window-air-conditioners decrease sharply and electrical power consumption increase considerably. These problems have activated the research programs in order to improve the performance of window-air-conditioners by enhancing heat transfer rate in the condenser. In this article, a new design with high commercialization potential for incorporating of evaporative cooling in the condenser of window-air-conditioner is introduced and experimentally investigated. A real air conditioner is used to test the innovation by putting two cooling pads in both sides of the air conditioner and injecting water on them in order to cool down the air before it passing over the condenser. The experimental results show that thermodynamic characteristics of new system are considerably improved and power consumption decreases by about 16% and the coefficient of performance increases by about 55%

  2. Application of evaporative cooling on the condenser of window-air-conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Hajidavalloo, Ebrahim [Shahid Chamran University, Department of Mechanical Engineering, Golestan St., Ahwaz, Khoozestan 61355 (Iran, Islamic Republic of)]. E-mail: hajidae_1999@yahoo.com

    2007-08-15

    Reduction of energy consumption is a major concern in the vapor compression refrigeration cycle especially in the area with very hot weather conditions (about 50 deg. C), where window-air-conditioners are usually used to cool homes. In this weather condition performance of air condenser window-air-conditioners decrease sharply and electrical power consumption increase considerably. These problems have activated the research programs in order to improve the performance of window-air-conditioners by enhancing heat transfer rate in the condenser. In this article, a new design with high commercialization potential for incorporating of evaporative cooling in the condenser of window-air-conditioner is introduced and experimentally investigated. A real air conditioner is used to test the innovation by putting two cooling pads in both sides of the air conditioner and injecting water on them in order to cool down the air before it passing over the condenser. The experimental results show that thermodynamic characteristics of new system are considerably improved and power consumption decreases by about 16% and the coefficient of performance increases by about 55%.

  3. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece

    International Nuclear Information System (INIS)

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-01-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑ 21 PBDE) in A/C dust ranged between 84 and 4062 ng g −1 with a median value of 1092 ng g −1 , while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day −1 (median 12 ng day −1 ). - Highlights: • PBDEs were investigated in dust of A/C filters in occupational settings in Thessaloniki, Greece. • BDE-209 was found to be the most abundant BDE congener. • High levels of PBDEs were found in a newspaper building, internet cafes and electronic shops. • PBDEs were attributable to the extensive presence and/or usage of electronic devices. • Exposure of employees to PBDEs via indoor dust ingestion was estimated at 12 ng day −1 . - PBDEs were for the first time measured in dust from central A/C filters in workplaces of Greece and their concentrations were used to estimate the non-dietary human exposure

  4. Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Thomas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Willem, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Ni, Chun Chun [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Stratton, Hannah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Chen, Yuting [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Ganeshalingam, Mohan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Iyer, Maithili [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Price, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Dunham, Camilla [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division

    2014-12-12

    As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States. LBNL performed its field-metering study from mid-April to late October 2014. The study, which monitored 19 sites in the Northeastern United States (4 in upstate New York and 15 near Philadelphia), collected real-time data on PAC energy consumption along with information regarding housing characteristics, consumer behavior, and environmental conditions that were expected to affect PAC performance. Given the limited number of test sites, this study was not intended to be statistically representative of PAC users in the United States but rather to understand the system response to the cooling demand and to

  5. The life cycle rebound effect of air-conditioner consumption in China

    International Nuclear Information System (INIS)

    Liu, Jingru; Sun, Xin; Lu, Bin; Zhang, Yunkun; Sun, Rui

    2016-01-01

    Highlights: • Develop a life cycle rebound effect model. • Assess the life cycle rebound effect of Chinese room air conditioners. • Conduct a questionnaire to assess the consumption behavior of Chinese room air conditioners. • Rebound effect should be considered by energy policy makers. - Abstract: Governments worldwide are attempting to reduce energy consumption and environmental pollution by confronting environmental problems and adopting more energy-efficient products. However, because of the rebound effect, energy-saving targets cannot always be fully achieved, and sometimes greater energy consumption is generated. Research on the rebound effect from the perspective of industrial ecology considers not only direct energy consumption but also its life cycle negative impacts on the environment with China’s rapid economic development and simultaneously improving quality of life, the ownership of room air conditioners (RACs) has increased more than three hundred times, and air conditioners’ energy consumption has increased one thousand times over the last twenty years. The Air Conditioner Energy Efficiency Standard is one of the most important measures in China for reducing the amount of energy consumed by RACs. This paper introduces a life cycle based method to estimate the rebound effect of Chinese RACs consumption. This model provides a product’s life-cycle view to assess the rebound effect, considering the contribution of both producer and consumer. Based on the established life cycle rebound effect model, we compared urban household RAC consumption behaviour before and after the launch of the Air Conditioner Energy Efficiency Standard. A rebound effect in RAC consumption was found that there was a longer daily usage period in the household as air conditioner efficiency levels improved. The life cycle rebound effect of household air-conditioner consumption was calculated to be 67%. The main conclusion obtained from this study is that policies and

  6. Thermoeconomic optimization of small size central air conditioner

    International Nuclear Information System (INIS)

    Zhang, G.Q.; Wang, L.; Liu, L.; Wang, Z.

    2004-01-01

    The application of thermoeconomic optimization design in an air-conditioning system is important in achieving economical life cycle cost. Previous work on thermoeconomic optimization mainly focused on directly calculating exergy input into the system. However, it is usually difficult to do so because of the uncertainty of input power of fan on the air side of the heat-exchanger and that of pump in the system. This paper introduces a new concept that exergy input into the system can be substituted for the sum of exergy destruction and exergy output from the system according to conservation of exergy. Although it is also difficult for a large-scale system to calculate exergy destruction, it is feasible to do so for a small-scale system, for instance, villa air conditioner (VAC). In order to perform thermoeconomic optimization, a program is firstly developed to evaluate the thermodynamic property of HFC134a on the basis of Martin-Hou state equation. Authors develop thermodynamic and thermoeconomic objective functions based on second law and thermoeconomic analysis of VAC system. Two optimization results are obtained. The design of VAC only aimed at decreasing the energy consumption is not comprehensive. Life cycle cost at thermoeconomic optimization is lower than that at thermodynamic optimization

  7. Elemental analysis of dust trapped in air conditioner filters for the assessment of Lahore city's air quality

    International Nuclear Information System (INIS)

    Siddique, N.

    2011-01-01

    A study was undertaken to assess the air quality of Lahore by the elemental analysis of air conditioner (AC) filter dust samples collected from 15 different commercial sites. Samples were prepared using the Leeds Public Analyst Method and were analyzed using instrumental neutron activation analysis (INAA) for up to 31 elements. The elements Al, As, Ba, Ce, Co, Cr, Cs, Fe, Hf, K, La, Lu, Mn, Na, Nd, Rb, Sc, Sm, Sn, Ta, Th, Yb and Zn were detected in all 15 samples whereas the remaining elements have been detected in fewer samples; i.e. Mg, Sb and Tb were detected in 14 samples, Br and V in ten samples, U in nine samples and Ca and Ti in eight samples only. Al, Ca, Fe, K, Mg and Na were determined in all samples at percentage levels. The concentrations of most elements were found to lie around the mean values for the 15 samples studied and were not orders of magnitude different. However the concentrations of Ca, Mg, Sn and Zn were found to be more variable and were found to be dependant on activities such as construction, fruit and vegetable handling, tin plating and transport, respectively. (author)

  8. Designing and testing the optimum design of automotive air-to-air thermoelectric air conditioner (TEAC) system

    International Nuclear Information System (INIS)

    Attar, Alaa; Lee, HoSung

    2016-01-01

    Highlights: • The optimum design of automotive thermoelectric AC system is proposed. • It is optimized by combining the thermal isolation and the dimensionless methods. • An experiment is conducted to validate the analytical design. - Abstract: The current project is discussing the optimization of counter flow air-to-air thermoelectric air conditioners (TEAC) system. Previous work showed an analytical model with experimental validation of a unit cell of TEAC system. However, the focus of this work is to simulate the optimum design of a whole TEAC system from given inlet parameters (i.e., hot and cold air mass flow rates and ambient temperatures). The analytical model was built by combining an optimal design method with dimensional analysis, which was recently developed, and the thermal isolation method in order to optimize the thermoelectric parameters (i.e., electrical current supplied and the number of thermocouples or the geometric factor, simultaneously). Moreover, based on the designed model, an experiment was conducted in order to study the accuracy of the analytical model. Even though the analytical model was built based on the thermoelectric ideal equations, it shows a good agreement with the experiment. This agreement was mainly a result of the use of the thermoelectric effective material properties which are obtained from the measured maximum thermoelectric module parameters. Since the experiment validate the analytical model, this model provides uncomplicated method to study the optimum design at given inputs.

  9. Superconducting ac cable

    Science.gov (United States)

    Schmidt, F.

    1980-11-01

    The components of a superconducting 110 kV ac cable for power ratings or = 2000 MVA were developed. The cable design is of the semiflexible type, with a rigid cryogenic envelope containing a flexible hollow coaxial cable core. The cable core consists of spirally wound Nb-A1 composite wires electrically insulated by high pressure polyethylene tape wrappings. A 35 m long single phase test cable with full load terminals rated at 110 kV and 10 kA was constructed and successfully tested. The results obtained prove the technical feasibility and capability of this cable design.

  10. ac superconducting articles

    International Nuclear Information System (INIS)

    Meyerhoff, R.W.

    1977-01-01

    A noval ac superconducting cable is described. It consists of a composite structure having a superconducting surface along with a high thermally conductive material wherein the superconducting surface has the desired physical properties, geometrical shape and surface finish produced by the steps of depositing a superconducting layer upon a substrate having a predetermined surface finish and shape which conforms to that of the desired superconducting article, depositing a supporting layer of material on the superconducting layer and removing the substrate, the surface of the superconductor being a replica of the substrate surface

  11. Superconducting ac cable

    International Nuclear Information System (INIS)

    Schmidt, F.

    1980-01-01

    The components of a superconducting 110 kV ac cable for power ratings >= 2000 MVA have been developed. The cable design especially considered was of the semiflexible type, with a rigid cryogenic envelope and flexible hollow coaxial cable cores pulled into the former. The cable core consists of spirally wound Nb-Al composite wires and a HDPE-tape wrapped electrical insulation. A 35 m long single phase test cable with full load terminations for 110 kV and 10 kA was constructed and successfully tested. The results obtained prove the technical feasibility and capability of our cable design. (orig.) [de

  12. [Research on dust mite allergen gathered from filters of air-conditioners].

    Science.gov (United States)

    Zhan, Xiao-dong; Wu, Hua; Hu, Hui-min; Li, Chao-pin

    2015-12-01

    To discuss the relation between the dust mite allergen (Der) in air-conditioner filters and the asthma attack. The dust samples were collected from the filters of air-conditioners in dining rooms, shopping malls, hotels and households, respectively. The concentrations of Der f 1 and Der p1 were detected by ELISA, and the dust mite immune activities were determined by dot-ELISA. The concentrations of Der f 1 in the dining rooms, shopping malls, hotels and households were 1.52, 1.24, 1.31 µg/g and 1.46 µg/g respectively, and the concentrations of Der p 1 were 1.23, 1.12, 1.16 µg/ g and 1.18 µg, respectively. One hour after the running of air-conditioners, the concentrations of Der f 1 and Der p 1 in the air were higher than those before the running of air-conditioners, and the differences were significant (P air-conditioners in domestic houses in Wuhu City, and the allergens can induce asthma.

  13. Technologies for high performance and energy saving in room air conditioners. Shoenegata kokoritsu eakon ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, N. (Toshiba Corp., Tokyo (Japan))

    1994-05-31

    An energy saving inverter type air-conditioner was introduced. It is important to increase the efficiency in the low capacity zone below the rated capacity to realize the energy saving. For the reduction of peak, improving the efficiency in the high capacity operation is also necessary. The power consumption in compressor and in inverter is about 90 % of the total power consumption in air-conditioner. The other 10 % are distributed to the fan motor and the control unit. For achieving the energy saving, the reduction of this 10 % part is also necessary because this 10 % part is constant regardless of the capacity of air-conditioner. The compressor motor was modified to the brushless DC motor with rotor position detecting device to improve the rotor structure and the position detection system. The heat exchanger was changed to a room heat exchanger with slit pattern. For the outdoor heat exchanger, the complex curvature blade fan was adopted. The control system of air-conditioner was changed. The PMV was previously learned and input in the microcomputer to calculate the data. Resultantly, the power consumption was reduced by about 20 % as compared with the conventional air-conditioner. 10 figs., 1 tab.

  14. Preliminary report of a gas conditioner to improve operational reliability of cryotherapy in developing countries

    Directory of Open Access Journals (Sweden)

    Broekhuizen Fredrik

    2006-02-01

    Full Text Available Abstract Background Cryotherapy is a safe, affordable, and effective method of treatment for cervical intraepithelial neoplasia. In some low-resource settings, environmental conditions or qualities of the refrigerant gas can lead to blockage of cryotherapy equipment, terminating treatment. A prototype of a gas conditioner to prevent operational failure was designed, built, and field tested. Methods The prototype conditioner device consists of an expansion chamber that filters and dries the refrigerant gas. Users in Peru and Kenya reported on their experience with the prototype conditioner. In Ghana, simulated cryotherapy procedures were used to test the effects of the prototype conditioner, as well as the commonly used "cough technique." Results Anecdotal reports from field use of the device were favorable. During simulated cryotherapy, the prevalence of blockage during freezing were 0% (0/25 with the device alone, 23.3% (7/30 with the cough technique alone, 5.9% (1/17 with both, and 55.2% (16/29 with neither (Pearson's Chi square = 26.6, df = 3, p Conclusion This prototype design of a cryotherapy gas conditioner is a potential solution for low-resource settings that are experiencing cryotherapy device malfunction.

  15. Net private benefits of purchasing eco-labeled air conditioners and subsidization policies in China

    International Nuclear Information System (INIS)

    Sun, Junxiu; Yin, Haitao; Wang, Feng

    2014-01-01

    Built on a data set of 527 air conditioner models collected from an online retailer, this study investigates whether the savings that consumers realize on their private electricity bills from purchasing energy-efficient appliances compensate for the additional cost of the appliances on the market, and if not, the size of the gap between the savings and the cost. Our findings show that, except for the most energy-efficient category, the cost savings from using energy-efficient air conditioners does compensate for their higher price. Therefore, any government subsidy should be reserved for the most efficient products. For less energy-efficient appliances, the best policy may be to provide more effective information instead of a subsidy because the subsidy might attract consumers away from more energy-efficient air conditioners and result in an unwanted effect. - Highlights: • This paper analyses the net private benefits of purchasing eco-labeled air conditioners in China. • There is no need to subsidize less energy-efficient air conditioners. • The most recently proposed policy development in China is a reform headed in the right direction

  16. Strategies for reducing the environmental impacts of room air conditioners in Europe

    International Nuclear Information System (INIS)

    Grignon-Masse, Laurent; Riviere, Philippe; Adnot, Jerome

    2011-01-01

    In Europe, buildings tend to be equipped with individual air conditioners, which constitute a fast growing electrical end-use. In this context, this study aims to assess the environmental impacts of European individual air conditioners and to analyse policy strategies to reduce these impacts. After analysing the European context concerning individual air conditioners, the environmental impacts of European air conditioners are assessed using a Life Cycle Analysis approach. The following step consists in studying, both technically and economically, different improvement options aiming at reducing the environmental impacts of these appliances. These results, obtained at the product level, are then generalised at the European level and different policy measures are defined and analysed. The main conclusion is that the implementation of a Minimum Energy Performance Standard based on Least Life Cycle Costs could save up to 49 TWh and 20 MtCO 2-eq in 2020 and be economically beneficial to the European end-user. - Research highlights: → A methodology based on Life Cycle Analysis is applied to European air conditioners. → Environmental impacts are mainly due to energy consumption. → There is a high potential for energy savings at very low costs for end users.

  17. Roseomonas aerofrigidensis sp. nov., isolated from an air conditioner.

    Science.gov (United States)

    Hyeon, Jong Woo; Jeon, Che Ok

    2017-10-01

    A Gram-stain-negative, strictly aerobic bacterium, designated HC1 T , was isolated from an air conditioner in South Korea. Cells were orange, non-motile cocci with oxidase- and catalase-positive activities and did not contain bacteriochlorophyll a. Growth of strain HC1 T was observed at 10-45 °C (optimum, 30 °C), pH 4.5-9.5 (optimum, pH 7.0) and 0-3 % (w/v) NaCl (optimum, 0 %). Strain HC1 T contained summed feature 8 (comprising C18 : 1ω7c/C18 : 1ω6c), C16 : 0 and cyclo-C19 : 0ω8c as the major fatty acids and ubiquinone-10 as the sole isoprenoid quinone. Phosphatidylglycerol, phosphatidylethanolamine, phosphatidylcholine and an unknown aminolipid were detected as the major polar lipids. The major carotenoid was hydroxyspirilloxanthin. The G+C content of the genomic DNA was 70.1 mol%. Phylogenetic analysis, based on 16S rRNA gene sequences, showed that strain HC1 T formed a phylogenetic lineage within the genus Roseomonas. Strain HC1 T was most closely related to the type strains of Roseomonas oryzae, Roseomonas rubra, Roseomonas aestuarii and Roseomonas rhizosphaerae with 98.1, 97.9, 97.6 and 96.8 % 16S rRNA gene sequence similarities, respectively, but the DNA-DNA relatedness values between strain HC1 T and closely related type strains were less than 70 %. Based on phenotypic, chemotaxonomic and molecular properties, strain HC1 T represents a novel species of the genus Roseomonas, for which the name Roseomonas aerofrigidensis sp. nov. is proposed. The type strain is HC1 T (=KACC 19097 T =JCM 31878 T ).

  18. Isolation and Identification of Pathogenic Fungi from Air Conditioners in Tutorial Rooms of the Faculty of Medicine, Universitas Padjadjaran

    Directory of Open Access Journals (Sweden)

    Gowre Govindasamy

    2014-02-01

    Full Text Available Background: Awareness about health problems caused by air conditioner is very important. Thus, it is crucial to have knowledge about proper maintenance of air conditioner. At the Faculty of Medicine, Universitas Padjadjaran, air conditioners are used in every tutorial rooms. This study was performed to provide adequate information on the fungi, such as Aspergillus, Penicillium and Mucor, found in air conditioners. Methods: A descriptive laboratory study was used to identify the presence and the type of pathogenic fungi from air conditioners in tutorial rooms. Thirty-four samples were collected from the air outlet grille of the air conditioners and cultured on Sabouraud agar at 27°C for 2 weeks. Fungi presence were then identified microscopically Results: The results showed that the majority of air conditioners in tutorial rooms of the Faculty of Medicine, University Padjadjaran contained many types of fungus that grew in Sabouraud agar. From 34 samples, thirty two samples were positive and 2 samples were negative. Various fungus have been identified, those were Penicillium (37.5%, Aspergillus (25%, Mucor (2.5% and unidentified (35% Conclusions : The majority of air conditioners in tutorial rooms of the Faculty of Medicine, University Padjadjaran contained many types of opportunistic fungus. [AMJ.2014;1(1:21–4

  19. High efficiency and long life of a three-phase power conditioner via interleave control

    Directory of Open Access Journals (Sweden)

    Kenji Amei

    2016-01-01

    Full Text Available This study describes the high efficiency and long life of three-phase power conditioners of a photovoltaic (PV system. The current PV system, which is widely spread, has two problems. The first problem is the lifetime of a power conditioner, whereas the other problem is the drop in the efficiency of the conversion because of the characteristics of the solar cell. For those problems, the solar panel and boost chopper circuit were divided into a plurality to configure a power conditioner, and an electrolytic capacitor-less driver with interleave control was realized. The drop in the current generated by the solar cell was suppressed, and an improvement in power generation efficiency was expected. The configuration and principle of a proposed circuit were explained, and results of simulation and experiment were reported.

  20. [Fungus microbiota in air conditioners in intensive care units in Teresina, Piauí].

    Science.gov (United States)

    Mobin, Mitra; do Amparo Salmito, Maria

    2006-01-01

    With the aim of identifying the fungus microbiota in air conditioners in intensive care units (ICUs) within public and private hospitals in Teresina, Piauí, solid material was collected from ten different ICUs. Thirty-three species of Moniliaceae and Dematiaceae were isolated, which was the first report of these in Piauí. High frequencies of Aspergillus niger Van Tieghem (60%), Aspergillus fumigatus Fres (50%), Trichoderma koningii Oudem (50%) and Aspergillus flavus Link: Fr. (40%) were recorded. The air conditioner cleanliness validity had expired in all the ICUs, and the quantity of colony-forming units exceeded the levels permitted by Law 176/00 from the Ministry of Health. It is important to provide individual protection equipment for professionals, adopt hospital infection control measures, raise the awareness of the presence of fungus infection, improve air circulation around the environment, periodically clean the air conditioners, and make health professionals alert to the importance of these fungi in the hospital environment.

  1. Characterization of the coal derived humic acids from Mukah, Sarawak as soil conditioner

    Directory of Open Access Journals (Sweden)

    Fong Sim Siong

    2006-01-01

    Full Text Available In Malaysia, abundant coal resources were found in Sarawak and Sabah. The utilization of coal resources, to date, is emphasized on the energy productions. The non-energy utilization as soil conditioner is unexplored. Therefore, this study attempted to characterize the coal humic acids extracted from Mukah coal and to evaluate its properties as soil conditioner. The coal humic acids from the regenerated sample were also assessed. The results revealed that different extractants and concentrations influenced the properties of humic acids. The extraction with KOH at 0.5 mol L-1 produced humic acids with low ash content and high acidic functional groups, which are substantial as soil conditioner. However, the yield was low. Regeneration of coal sample with 10% nitric acids improved the yield to an average of 83.45%. The acidic functional groups of nitrohumic acids were improved with the ash content remained at a low level.

  2. A desiccant-enhanced evaporative air conditioner: Numerical model and experiments

    International Nuclear Information System (INIS)

    Woods, Jason; Kozubal, Eric

    2013-01-01

    Highlights: ► We studied a new process combining liquid desiccants and evaporative cooling. ► We modeled the process using a finite-difference numerical model. ► We measured the performance of the process with experimental prototypes. ► Results show agreement between model and experiment of ±10%. ► Results add confidence to previous modeled energy savings estimates of 40–85%. - Abstract: This article presents modeling and experimental results on a recently proposed liquid desiccant air conditioner, which consists of two stages: a liquid desiccant dehumidifier and an indirect evaporative cooler. Each stage is a stack of channel pairs, where a channel pair is a process air channel separated from an exhaust air channel with a thin plastic plate. In the first stage, a liquid desiccant film, which lines the process air channels, removes moisture from the air through a porous hydrophobic membrane. An evaporating water film wets the surface of the exhaust channels and transfers the enthalpy of vaporization from the liquid desiccant into an exhaust airstream, cooling the desiccant and enabling lower outlet humidity. The second stage is a counterflow indirect evaporative cooler that siphons off and uses a portion of the cool-dry air exiting the second stage as the evaporative sink. The objectives of this article are to (1) present fluid-thermal numerical models for each stage, (2) present experimental results of prototypes for each stage, and (3) compare the modeled and experimental results. Several experiments were performed on the prototypes over a range of inlet temperatures and humidities, process and exhaust air flow rates, and desiccant concentrations and flow rates. The model predicts the experiments within ±10%.

  3. Chemical Risk Evaluation: A Case Study in an Automotive Air Conditioner Production Facility

    Directory of Open Access Journals (Sweden)

    Tengku Hanidza T.I.

    2010-01-01

    Full Text Available There has been limited knowledge on worker’s exposure to chemicals used in the automotive industries. The purpose of this study is to assess chemical risk and to determine the adequacy of the existing control measures to reduce chemical exposure. A cross sectional survey was conducted in a factory involving installation and servicing of automotive air conditioner units. Qualitative exposure assessment was carried out following the Malaysian Chemical Health Risk Assessment Manual (CHRA. There were 180 employees, 156 workers worked in the production line, which constitutes six work units Tube fin pressed, Brazing, Welding, Final assembly, Piping and Kit II. From the chemical risk evaluation for each work unit, 26 chemical compounds were used. Most of the chemicals were irritants (eye and skin and some were asphyxiants and sensitizers. Based on the work assignment, 93 out of 180 (51.67% of the workers were exposed to chemicals. The highest numbers of workers exposed to chemicals were from the Brazing section (22.22% while the Final Assembly section was the lowest (1.67%. Health survey among the workers showed occurrence of eye irritation, skin irritation, and respiratory irritation, symptoms usually associated with chemical exposure. Using a risk rating matrix, several work process were identified as having ‘significant risk’. For these areas, the workers are at risk of adverse health effects since chemical exposure is not adequately controlled. This study recommends corrective actions be taken in order to control the level of exposure and to provide a safe work environment for workers.

  4. Accelerating Improvements in the Energy Efficiency of Room Air Conditioners (RACs) in India: Potential, Cost-Benefit, and Policies (Interim Assessment)

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-06-01

    Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by

  5. Numerical study of the flow conditioner for the IFMIF liquid lithium target

    Energy Technology Data Exchange (ETDEWEB)

    Gordeev, S., E-mail: sergej.gordeev@kit.edu [Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute for Thechnology, Campus North, Hermann v. Helmholtz Platz 1, D76344, Eggenstein-Leopoldshafen (Germany); Gröschel, F. [KIT Fusion Program, Karlsruhe Institute for Thechnology, Campus North, Hermann v. Helmholtz Platz 1, D76344, Eggenstein-Leopoldshafen (Germany); Heinzel, V.; Hering, W.; Stieglitz, R. [Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute for Thechnology, Campus North, Hermann v. Helmholtz Platz 1, D76344, Eggenstein-Leopoldshafen (Germany)

    2014-10-15

    Highlights: • A detailed numerical analysis of the flow conditioner efficiency has been performed. • The calculations show that the present design of the flow conditioner cannot suppress swirl motions emerging from the bend. • The transient simulation reveals flow instabilities between the separation zone and the accelerated outer region. • Calculation shows that pitched guide vanes upstream the elbow reduces a generation of backflow areas downstream. - Abstract: IFMIF (International Fusion Materials Irradiation Facility) is an accelerator-based deuteron–lithium (D–Li) neutron source to simulate the neutron irradiation field in a fusion reactor. The target assembly of the IFMIF consists of the flow conditioners and the nozzle, which has to form a stable lithium jet. This work focuses on a numerical study of the flow conditioner efficiency, in which two different types of flow conditioners are compared by means of a detailed numerical analysis with respect to specific hydraulic effects in the pipe elbow and the inflow conditioners. The adequateness of three different turbulence models to simulate a flow through a 90° bend of circular cross section has been examined. The calculations show that a honeycomb-screen combination is not capable to suppress effectively large scale swirl motions emerging from the bend. An increasing number of screens improves the flow uniformity downstream, but increases the pressure drop. In order to detect any transient effects in the separation area a flow straightener configuration consisting of a honeycomb with a subsequent screen has been analyzed by means of a detached eddy simulation (DES). A frequency analysis of the normalized static pressure amplitude conducted by means of a detached eddy simulation (DES) reveals instabilities in the shear layer between the separation zone and the accelerated outer region, which additionally increase the inhomogeneity of the axial velocity distribution. A set of six circumferentially

  6. Potential CO{sub 2} reduction by implementing energy efficiency standard for room air conditioner in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Masjuki, H.H.; Choudhury, I.A.; Saidur, R. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2001-09-01

    This study attempts to predict the environmental impact of implementing an energy efficiency standard for room air conditioners in Malaysia. The ownership of room air conditioners has increased tremendously in this country. At present, there are about 528,792 room air conditioners in Malaysian households. In the year 2020, it will be about 1,511,276. The potential carbon dioxide reduction is based on the predicted electricity savings from implementing a minimum energy efficiency standard for room air conditioners. The electricity savings are calculated based on the predicted electricity consumption by a single air conditioner in the Malaysian household. The replacement of less efficient units of this appliance is reflected in reduced electricity consumption and emissions from power plants. The energy efficiency provisions of this regulation and agreement provide targets to save money, energy and, most importantly, to protect the environment. (Author)

  7. ACS Postflash Characterization

    Science.gov (United States)

    Smith, Linda

    2011-10-01

    This program will evaluate the in-flight performance of the ACS/WFC post-flash lamp. A series of observations of Omega Cen will be taken using short and long exposures. The short exposures will be post-flashed using pre-determined exposure times to produce backgrounds from 0 to 125 e-. The data will be used to {1} make an empirical study of the effectiveness in preserving counts for faint stars on various post-flash backgrounds; {2} validate that our current mechanisms for formula-based and pixel-based corrections provide good fixes for whatever CTE remains; and {3} probe a fine enough range of backgrounds that users will be able to pick the level that optimizes their science, which will be a straightforward compromise between the noise added and the signal preserved.

  8. Faradaic AC Electrokinetic Flow and Particle Traps

    Science.gov (United States)

    Ben, Yuxing; Chang, Hsueh-Chia

    2004-11-01

    Faradaic reaction at higher voltages can produce co-ion polarization at AC electrodes instead of counter-ion polarization due to capacitive charging from the bulk. The Faradaic co-ion polarization also does not screen the external field and hence can produce large net electro-kinetic flows at frequencies lower than the inverse RC time of the double layer. Due to the opposite polarization of capacitve and Faradaic charging, we can reverse the direction of AC flows on electrodes by changing the voltage and frequency. Particles and bacteria are trapped and then dispersed at stagnation lines, at locations predicted by our theory, by using these two flows sequentially. This technique offers a good way to concentrate and detect bacteria.

  9. ACS Photometric Zero Point Verification

    Science.gov (United States)

    Dolphin, Andrew

    2003-07-01

    The uncertainties in the photometric zero points create a fundamental limit to the accuracy of photometry. The current state of the ACS calibration is surprisingly poor, with zero point uncertainties of 0.03 magnitudes in the Johnson filters. The reason for this is that ACS observations of excellent ground-based standard fields, such as the omega Cen field used for WFPC2 calibrations, have not been obtained. Instead, the ACS photometric calibrations are based primarily on semi-emprical synthetic zero points and observations of fields too crowded for accurate ground-based photometry. I propose to remedy this problem by obtaining ACS broadband images of the omega Cen standard field with both the WFC and HRC. This will permit the direct determination of the ACS transformations, and is expected to double the accuracy to which the ACS zero points are known. A second benefit is that it will facilitate the comparison of the WFPC2 and ACS photometric systems, which will be important as WFPC2 is phased out and ACS becomes HST's primary imager.

  10. Simulation Models of Leaf Area Index and Yield for Cotton Grown with Different Soil Conditioners.

    Directory of Open Access Journals (Sweden)

    Lijun Su

    Full Text Available Simulation models of leaf area index (LAI and yield for cotton can provide a theoretical foundation for predicting future variations in yield. This paper analyses the increase in LAI and the relationships between LAI, dry matter, and yield for cotton under three soil conditioners near Korla, Xinjiang, China. Dynamic changes in cotton LAI were evaluated using modified logistic, Gaussian, modified Gaussian, log normal, and cubic polynomial models. Universal models for simulating the relative leaf area index (RLAI were established in which the application rate of soil conditioner was used to estimate the maximum LAI (LAIm. In addition, the relationships between LAIm and dry matter mass, yield, and the harvest index were investigated, and a simulation model for yield is proposed. A feasibility analysis of the models indicated that the cubic polynomial and Gaussian models were less accurate than the other three models for simulating increases in RLAI. Despite significant differences in LAIs under the type and amount of soil conditioner applied, LAIm could be described by aboveground dry matter using Michaelis-Menten kinetics. Moreover, the simulation model for cotton yield based on LAIm and the harvest index presented in this work provided important theoretical insights for improving water use efficiency in cotton cultivation and for identifying optimal application rates of soil conditioners.

  11. Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control

    Science.gov (United States)

    2012-11-01

    reading Current transformer Regen and conditioner Continental Controls CTS-0750-30 1 % of reading Pyranometer Horizontal Campbell...indoor comfort conditions. A pyranometer was used to quantify the efficiency of the solar collector array. Two measurements of electric energy were

  12. Dynamic performance of self-operated three-way valve used in a hybrid air conditioner

    International Nuclear Information System (INIS)

    Zhang, Penglei; Zhou, Dehai; Shi, Wenxing; Li, Xianting; Wang, Baolong

    2014-01-01

    A hybrid air conditioner combining a thermosyphon cycle with a vapor compression refrigeration cycle has a large energy saving potential compared with a common air conditioner for spaces requiring year-round cooling. The performance of the switch between the vapor compression mode and the thermosyphon mode largely impacts the safety and reliability of hybrid air conditioners. Therefore, a self-operated three-way valve is proposed. A thermodynamic model and a kinetic model are developed in this paper to evaluate the dynamic performance of the switch valve. The effects of the spring force constant, compressor discharging volume, fit clearance and piston length on the dynamic performance of the switch valve are analyzed. In conclusion, the proposed self-operated three-way valve can realize the switch operation accurately. - Highlights: •A self-operated three-way valve is proposed for hybrid air conditioners. •The thermodynamic model and kinetic model of the self-operated three-way valve are developed. •The validity of models is verified by experiments. •Effects of four main design parameters on the operating performance of the valve are researched

  13. Feasibility study of a green energy powered thermoelectric chip based air conditioner for electric vehicles

    International Nuclear Information System (INIS)

    Miranda, Á.G.; Chen, T.S.; Hong, C.W.

    2013-01-01

    Traditional compressed-refrigerant air conditioning systems consume substantial energy that may reduce the driving performance and cruising mileage of electric vehicles considerably. It is crucial to design a new climate control system, using a direct energy conversion principle, to further aid in the commercialization of modern electric vehicles. A solid state air conditioner model consisting on TECs (thermoelectric chips) as the load, DSSCs (dye sensitized solar cells) as the renewable energy source and high power LiBs (lithium-ion batteries) as an energy storage device are considered for a personal mobility vehicle. The power management between the main power net and the solid state air conditioner interface is designed with an outer proportional-integral controller and an inner passivity based current controller with a loss included model for perfect tracking. This model is intended to comprise thermal and electrical elements which can be tunable for performance benchmarking and optimization of a solid state air conditioning system. Dynamic performance simulations of the solid-state air conditioner are performed, alongside guidelines for feasibility. - Highlights: • Alternative model extraction for dye sensitized solar cells. • Improved and computationally fast model for the cabin air temperature dynamics. • Euler–Lagrange loss included modeling of a buck converter. • Loss-included passivity based inner loop current control. • The thermoelectric chip air conditioner is tested in simulated cooling/heating scenarios

  14. Energy reduction of building air-conditioner with phase change material in Thailand

    Directory of Open Access Journals (Sweden)

    Nattaporn Chaiyat

    2014-11-01

    Full Text Available In this study, a concept of using phase change material (PCM for improving cooling efficiency of an air-conditioner had been presented under Thai climate. Paraffin waxes melting point at around 20 °C was selected to evaluate the thermal performance by reducing the air temperature entering the evaporating coil. The model of PCM celluloid balls had been performed with the air-conditioner. Moreover, the mathematical model of the air-conditioner with the PCM storage was developed and verified with the testing results. From the study results, it could be seen that the simulated data agreed quite well with the experimental result at the discrepant around 2–4%. Finally, the model was used to analyze the economic result which was found that the electrical consumption of the modified air-conditioner could be decreased 3.09 kW h/d. The electrical power consumption of the modified unit was 36.27 kW h/d at the operating time 15 h/d compared with 39.36 kW h/d of the normal unit at the operating time 12 h/d. The saving cost of the PCM bed could be 9.10% or 170.03 USD and the payback period was 4.15 y.

  15. Product lifetime, energy efficiency and climate change: A case study of air conditioners in Japan.

    Science.gov (United States)

    Nishijima, Daisuke

    2016-10-01

    This study proposed a modelling technique for estimating life-cycle CO2 emissions of durable goods by considering changes in product lifetime and energy efficiency. The stock and flow of durable goods was modelled by Weibull lifetime distributions and the trend in annual energy efficiency (i.e., annual electricity consumption) of an "average" durable good was formulated as a reverse logistic curve including a technologically critical value (i.e., limit energy efficiency) with respect to time. I found that when the average product lifetime is reduced, there is a trade-off between the reduction in emissions during product use (use phase), due to the additional purchases of new, more energy-efficient air conditioners, and the increase in emissions arising from the additional production of new air conditioners stimulated by the reduction of the average product lifetime. A scenario analysis focused on residential air conditioners in Japan during 1972-2013 showed that for a reduction of average lifetime of 1 year, if the air conditioner energy efficiency limit can be improved by 1.4% from the estimated current efficiency level, then CO2 emissions can be reduced by approximately the same amount as for an extension of average product lifetime of 1 year. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Acoustic resonance of outer-rotor brushless dc motor for air-conditioner fan

    Science.gov (United States)

    Lee, Hong-Joo; Chung, Shi-Uk; Hwang, Sang-Moon

    2008-04-01

    Generation of acoustic noise in electric motor is an interacting combination of mechanical and electromagnetic sources. In this paper, a brushless dc motor for air-conditioner fan is analyzed by finite element method to identify noise source, and the analysis results are verified by experiments, and sensitivity analysis is performed by design of experiments.

  17. The Hubble Legacy Archive ACS grism data

    Science.gov (United States)

    Kümmel, M.; Rosati, P.; Fosbury, R.; Haase, J.; Hook, R. N.; Kuntschner, H.; Lombardi, M.; Micol, A.; Nilsson, K. K.; Stoehr, F.; Walsh, J. R.

    2011-06-01

    A public release of slitless spectra, obtained with ACS/WFC and the G800L grism, is presented. Spectra were automatically extracted in a uniform way from 153 archival fields (or "associations") distributed across the two Galactic caps, covering all observations to 2008. The ACS G800L grism provides a wavelength range of 0.55-1.00 μm, with a dispersion of 40 Å/pixel and a resolution of ~80 Å for point-like sources. The ACS G800L images and matched direct images were reduced with an automatic pipeline that handles all steps from archive retrieval, alignment and astrometric calibration, direct image combination, catalogue generation, spectral extraction and collection of metadata. The large number of extracted spectra (73,581) demanded automatic methods for quality control and an automated classification algorithm was trained on the visual inspection of several thousand spectra. The final sample of quality controlled spectra includes 47 919 datasets (65% of the total number of extracted spectra) for 32 149 unique objects, with a median iAB-band magnitude of 23.7, reaching 26.5 AB for the faintest objects. Each released dataset contains science-ready 1D and 2D spectra, as well as multi-band image cutouts of corresponding sources and a useful preview page summarising the direct and slitless data, astrometric and photometric parameters. This release is part of the continuing effort to enhance the content of the Hubble Legacy Archive (HLA) with highly processed data products which significantly facilitate the scientific exploitation of the Hubble data. In order to characterize the slitless spectra, emission-line flux and equivalent width sensitivity of the ACS data were compared with public ground-based spectra in the GOODS-South field. An example list of emission line galaxies with two or more identified lines is also included, covering the redshift range 0.2 - 4.6. Almost all redshift determinations outside of the GOODS fields are new. The scope of science projects

  18. Application of best practice for setting minimum energy efficiency standards in technically disadvantaged countries: Case study of Air Conditioners in Brunei Darussalam

    International Nuclear Information System (INIS)

    Shi, Xunpeng

    2015-01-01

    Highlights: • Setting MEPS requires significant data, financial resources and technical capacity. • Application of best practice in technical disadvantaged countries (TDCs) was demonstrated. • Best practice was successfully applied to Brunei for its AC MEPS. • For Brunei, COP at 2.9 is recommended and 15% efficiency improvement is achievable. • The methodology is applicable to other appliances in any TDCs. - Abstract: Application of the best practice of setting minimum energy performance standards (MEPS) in technically disadvantaged countries (TDCs) faces many barriers. The best practice of determining MEPS has a comprehensive analytical framework including engineering-economic analysis, life-cycle cost-benefit analysis, as well stakeholders’ and market impact assessments. However, TDCs usually are lack of reference product classes, market data, and other necessary inputs data. This study demonstrated how to overcome those barriers to apply the best practice to TDCs using the actual experience in setting initial MEPS for Air Conditioners (ACs) in Brunei from scratch with limited secondary data as an example. The series of application works include definition of the product classes and the baseline group; collection of market data; formulation of cost-efficiency relationship from the market data; examination of the economic, environmental, and financial impacts of various MEPS options; revealing of the consumers’ willingness to pay; and analysis of the impacts and responses from the industry and consumers. The coordination with the compliance of the Montreal Protocol was also considered. The methodology should also be applicable to setting MEPF for other appliances in any TDCs.

  19. Introduction to AC machine design

    CERN Document Server

    Lipo, Thomas A

    2018-01-01

    AC electrical machine design is a key skill set for developing competitive electric motors and generators for applications in industry, aerospace, and defense. This book presents a thorough treatment of AC machine design, starting from basic electromagnetic principles and continuing through the various design aspects of an induction machine. Introduction to AC Machine Design includes one chapter each on the design of permanent magnet machines, synchronous machines, and thermal design. It also offers a basic treatment of the use of finite elements to compute the magnetic field within a machine without interfering with the initial comprehension of the core subject matter. Based on the author's notes, as well as after years of classroom instruction, Introduction to AC Machine Design: * Brings to light more advanced principles of machine design--not just the basic principles of AC and DC machine behavior * Introduces electrical machine design to neophytes while also being a resource for experienced designers * ...

  20. The Signal Validation method of Digital Process Instrumentation System on signal conditioner for SMART

    International Nuclear Information System (INIS)

    Moon, Hee Gun; Park, Sang Min; Kim, Jung Seon; Shon, Chang Ho; Park, Heui Youn; Koo, In Soo

    2005-01-01

    The function of PIS(Process Instrumentation System) for SMART is to acquire the process data from sensor or transmitter. The PIS consists of signal conditioner, A/D converter, DSP(Digital Signal Process) and NIC(Network Interface Card). So, It is fully digital system after A/D converter. The PI cabinet and PDAS(Plant Data Acquisition System) in commercial plant is responsible for data acquisition of the sensor or transmitter include RTD, TC, level, flow, pressure and so on. The PDAS has the software that processes each sensor data and PI cabinet has the signal conditioner, which is need for maintenance and test. The signal conditioner has the potentiometer to adjust the span and zero for test and maintenance. The PIS of SMART also has the signal conditioner which has the span and zero adjust same as the commercial plant because the signal conditioner perform the signal condition for AD converter such as 0∼10Vdc. But, To adjust span and zero is manual test and calibration. So, This paper presents the method of signal validation and calibration, which is used by digital feature in SMART. There are I/E(current to voltage), R/E(resistor to voltage), F/E(frequency to voltage), V/V(voltage to voltage). Etc. In this paper show only the signal validation and calibration about I/E converter that convert level, pressure, flow such as 4∼20mA into signal for AD conversion such as 0∼10Vdc

  1. Comparative scanning electron microscopic study of the effect of different dental conditioners on dentin micromorphology

    Directory of Open Access Journals (Sweden)

    Alexandre Henrique Susin

    2008-04-01

    Full Text Available This study evaluated comparatively by scanning electron microscopy (SEM the effect of different dental conditioners on dentin micromorphology, when used according to the same protocol. Forty dentin sticks were obtained from 20 caries-free third human molars and were assigned to 4 groups corresponding to 3 conditioners (phosphoric acid 37%, Clearfil SE Bond and iBond and an untreated control group. After application of the conditioners, the specimens were immersed in 50% ethanol solution during 10 s, chemically fixed and dehydrated to prepare them to SEM analysis. In the control group, dentin surface was completely covered by smear layer and all dentinal tubules were occluded. In the phosphoric acid-etched group, dentin surface was completely clean and presented exposed dentinal tubule openings; this was the only group in which the tubules exhibited the funnel-shaped aspect. In the groups conditioned with Clearfil SE Bond primer and iBond, which are less acidic than phosphoric acid, tubule openings were occluded or partially occluded, though smear layer removal was observed. SE Bond was more efficient in removing the smear layer than iBond. In the Clearfil SE Bond group, the cuff-like aspect of peritubular dentin was more evident. It may be concluded all tested conditioners were able to change dentin morphology. However, it cannot be stated that the agent aggressiveness was the only cause of the micromorphological alterations because a single morphological pattern was not established for each group, but rather an association of different aspects, according to the aggressiveness of the tested conditioner.

  2. Aislamiento acústico

    Directory of Open Access Journals (Sweden)

    Tobío, J. M.

    1970-07-01

    Full Text Available This is a very specific subject in the field of architectural acoustics, namely, insulation'. Emphasis is placed on the theoretical foundations of this phenomenon, and the most simple formula are developed to calculate easily the transmission losses of a material or the constructional insulating arrangements. The practical aspect of insulation can be considered by means of several graphs and charts, without the use of mathematics, and utilising common materials, that will not substantially increase the cost of the project. Finally this papers offers a critical discussion of building codes, and their reference to the acoustical insulation of dwellings, and data is included on the new regulations of the Madrid Municipality.Se trata un tema muy concreto de la Acústica Arquitectónica, el aislamiento, haciendo hincapié en los fundamentos teóricos del fenómeno y estableciendo las fórmulas más sencillas que permiten calcular fácilmente las pérdidas de transmisión de un material o disposición constructiva aislante. Varias gráficas y abacos permiten abordar, sin ningún tratamiento matemático, el problema práctico del aislamiento, aprovechando los materiales comunes y sin ocasionar gastos que graven sustancialmente el importe del proyecto. Por último, se hace un estudio crítico de las normas y su incidencia en los problemas del aislamiento de viviendas, incluyendo datos referentes a la nueva Ordenanza del Ayuntamiento de Madrid.

  3. Programmable Power Supply for AC Switching Magnet of Proton Accelerator

    CERN Document Server

    Jeong, Seong-Hun; Kang Heung Sik; Lee, Chi-Hwan; Lee, Hong-Gi; Park, Ki-Hyeon; Ryu, Chun-Kil; Sik Han, Hong; Suck Suh, Hyung

    2005-01-01

    The 100-MeV PEFP proton linac has two proton beam extraction lines for user' experiment. Each extraction line has 5 beamlines and has 5 Hz operating frequency. An AC switching magnet is used to distribute the proton beam to the 5 beamlines, An AC switching magnet is powered by PWM-controlled bipolar switching-mode converters. This converter is designed to operate at ±350A, 5 Hz programmable step output. The power supply is employed IGBT module and has controlled by a DSP (Digital Signal Process). This paper describes the design and test results of the power supply.

  4. c-axis ac susceptibility in high-Tc superconductors

    International Nuclear Information System (INIS)

    Waldmann, O.; Lichtschlag, G.; Talalaevskii, A.; Kleiner, R.; Mueller, P.; Steinmeyer, F.; Gerhaeuser, W.

    1996-01-01

    We have investigated the angle and magnetic field dependence of the ac susceptibility in Bi 2 Sr 2 CaCu 2 O 8 and YBa 2 Cu 3 O 7 single crystals at low external fields. The ac field was applied perpendicular to the CuO 2 planes. The first and third harmonics of the ac susceptibility exhibit remarkably sharp features when the dc field component perpendicular to the CuO 2 planes passes a threshold field H th . H th is strongly temperature dependent, but is independent of the parallel field component. We propose a simple model which excellently explains the data. Within this model the peak structures are related to the irreversibility line. We discuss the implications of the model for the interpretation of the ac susceptibility. copyright 1996 The American Physical Society

  5. The role of technology, product lifetime, and energy efficiency in climate mitigation: A case study of air conditioners in Japan

    International Nuclear Information System (INIS)

    Nishijima, Daisuke

    2017-01-01

    This study analyzed the impact on the life-cycle CO_2 emissions derived from a specific durable good (i.e., household air conditioners in this study) of industrial technology changes, product lifetime changes, and energy efficiency improvements. I proposed a comprehensive structural decomposition analysis including two factors of average lifetime and energy efficiency trend of household air conditioners and applied the decomposition method to the Japanese environmental input-output tables of 1990, 1995, 2000, and 2005. The empirical results show that “Household air-conditioner sector” itself contributed to reducing life-cycle CO_2 emissions derived from household air conditioners, while other sectors such as “On-site power generation sector” and “Retail trade sector” contributed to increasing life-cycle CO_2 emissions derived from household air conditioners. I also conducted combined scenario analysis about reduction potential of product lifetime and energy efficiency of air conditioners and the results showed the reduction rate of energy efficiency necessary for maintain CO_2 emissions in 2005 at 1990 level on each average lifetime scenario. (e.g. if average lifetime of air conditioners is shortened by 1 year, energy efficiency of air conditioners have to be further improved by 20.6% from current level. - Highlights: • This study provides a decomposition framework for air conditioner’s CO_2 emissions. • Technology, product lifetime and energy efficiency are considered in the framework. • “Household air conditioner” sector contributed to reducing CO_2 emissions largely. • “On-site power generation” indirectly contributed to increasing CO_2 emissions. • I showed the improvement rates of energy efficiency to achieve a reduction target.

  6. Assessing Fungal Population in Soil Planted with Cry1Ac and CPTI Transgenic Cotton and Its Conventional Parental Line using 18S and ITS rDNA Sequences over Four Seasons

    Directory of Open Access Journals (Sweden)

    Xiemin Qi

    2016-07-01

    Full Text Available Long-term growth of genetically modified plants (GMPs has raised concerns regarding their ecological effects. Here, FLX-pyrosequencing of region I (18S and region II (ITS1, 5.8S and ITS2 rDNA was used to characterize fungal communities in soil samples after 10-year monoculture of one representative transgenic cotton line (TC-10 and 15-year plantation of various transgenic cotton cultivars (TC-15mix over four seasons. Soil fungal communities in the rhizosphere of non-transgenic control (CC were also compared. No notable differences were observed in soil fertility variables among CC, TC-10 and TC-15mix. Within seasons, the different estimations were statistically indistinguishable. There were 411 and 2 067 fungal operational taxonomic units in the two regions, respectively. More than 75% of fungal taxa were stable in both CC and TC except for individual taxa with significantly different abundance between TC and CC. Statistical analysis revealed no significant differences between CC and TC-10, while discrimination of separating TC-15mix from CC and TC-10 with 37.86% explained variance in PCoA and a significant difference of Shannon indexes between TC-10 and TC-15mix were observed in region II. As TC-15mix planted with a mixture of transgenic cottons (Zhongmian-29, 30, and 33B for over 5 years, different genetic modifications may introduce variations in fungal diversity. Further clarification is necessary by detecting the fungal dynamic changes in sites planted in monoculture of various transgenic cottons. Overall, we conclude that monoculture of one representative transgenic cotton cultivar may have no effect on fungal diversity compared with conventional cotton. Furthermore, the choice of amplified region and methodology has potential to affect the outcome of the comparison between GM-crop and its parental line.

  7. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    International Nuclear Information System (INIS)

    Zhang Weijiang; Zhang Chunlu

    2011-01-01

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed.

  8. [Air-conditioner disease. Results of an industrial medicine survey (author's transl)].

    Science.gov (United States)

    Molina, C; Aiache, J M; Bedu, M; Menaut, P; Wahl, D; Brestowski, J; Grall, Y

    1982-07-03

    The results of a survey conducted in a company employing 1850 persons working in air-conditioned premises are reported. One hundred and five persons were examined, including 790 who mostly complained of respiratory disorders and 20 controls. Regular check-ups during the last two years have failed to reveal any serious disease. The most frequent complaints were rhinitis and tracheitis, especially among female employees. No alveolitis was observed. The finding of Bacillus subtilis in samples of ambient air and air-conditioner filters in conjunction with the presence of precipitating antibodies against crude extracts from these samples, suggested that the respiratory disorders might have been due to this microorganism. A multifactorial analysis demonstrated a statistically significant correlation between clinical symptoms and immunological disorders. The air-conditioner disease, therefore, may present as a benign condition.

  9. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei-Jiang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang, Chun-Lu [College of Mechanical Engineering, Tongji University, 4800 Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed. (author)

  10. Study of noise in offices with window-type room air-conditioners

    International Nuclear Information System (INIS)

    Shaikh, G.H.; Hashmi, R.; Shareef, A.

    2005-01-01

    A Study of Noise has been carried out in 17 private offices, with window-type room air-conditioners, to assess noise levels in these offices. A-Weighted equivalent sound-pressure levels (dB(A) LAeq) and equivalent octave-band sound-pressure levels (dB Leq) were measured in each office, and Preferred Speech Interference Levels (PSIL) evaluated. The results show that the interior noise-levels in these offices vary from 59.6 to 72.2 dB(A) LAeq. which are very high and much above the interior noise limits, recommended for offices by some individual workers. Some ways and means to limit its emission of high level of noise from the air conditioners are also discussed. (author)

  11. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Weijiang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang Chunlu, E-mail: chunlu.zhang@carrier.utc.co [College of Mechanical Engineering, Tongji University, 4800 Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed.

  12. A LVDT conditioner for the beam profile monitors of the AmPS

    International Nuclear Information System (INIS)

    Es, J.T. van; Trigt, J.H. van.

    1991-01-01

    A LVDT (Linear Variable Differential Transformer) is a transducer for localization. Because of its applied materials, its construction and the absence of bearings etc. the instrument is suitable to be applied in locations where radioactive radiation is present. In order to obtain information about the position of the iron core in the transducer, a conditioner is needed. In 1977 by Digel a conditioner has been developed for the beam profile monitors (moving wire) of MEA because the 'market' could not meet the requirements then. Nowadays the 'market' offers i.c.'s which can take over the work of the Eurocard developed then. Digel has investigated them in order to see if they are applicable for the beam profile monitors of AmPS. (author). 5 refs.; 7 figs.; 13 tabs

  13. Dynamic modeling of brushless dc motor-power conditioner unit for electromechanical actuator application

    Science.gov (United States)

    Demerdash, N. A.; Nehl, T. W.

    1979-01-01

    A comprehensive digital model for the analysis of the dynamic-instantaneous performance of a power conditioner fed samarium-cobalt permanent magnet brushless DC motor is presented. The particular power conditioner-machine system at hand, for which this model was developed, is a component of an actual prototype electromechanical actuator built for NASA-JSC as a possible alternative to hydraulic actuators as part of feasibility studies for the shuttle orbiter applications. Excellent correlation between digital simulated and experimentally obtained performance data was achieved for this specific prototype. This is reported on in this paper. Details of one component of the model, its applications and the corresponding results are given in this paper.

  14. The application of fuzzy control on energy saving for multi-unit room air-conditioners

    International Nuclear Information System (INIS)

    Chiou, C.B.; Chiou, C.H.; Chu, C.M.; Lin, S.L.

    2009-01-01

    Most research, on energy saving methods for air-conditioners have focused on large chillers as its subject. As most school offices, laboratories, and classrooms are equipped with unitary systems for air-conditioning, this paper discusses methods for energy savings with regard to unitary systems. This paper will put forward the fuzzy temperature control method for multi-unit air-conditioners to enhance energy efficiency. The results show that the use of fuzzy control is efficient for energy saving as well as causing temperature control be steadier, even if there is a change to the thermal loading, the fuzzy control system is able to control the air-conditioning in stable conditions

  15. Effect of Agri-SC as a soil conditioner on runoff, soil loss and crust ...

    African Journals Online (AJOL)

    This study was carried out to determine the effect of Agri-SC as a soil conditioner at different doses (0, 18.50, 37.00, 55.50 and 74.00 l ha-1) on water erosion and crust strengths under laboratory conditions with three replicates. The Agri-SC solutions were sprayed and two consecutive simulated rainfalls (60 mm h-1) were ...

  16. Influence of local air velocity from air conditioner evaluated by salivary and skin biomarkers

    OpenAIRE

    Yamaguchi, Masaki; Takahashi, Takayuki; Yoshino, Yuichiro; Sasaki, Makoto; Nishiyama, Hajime

    2010-01-01

    The purpose of this paper is to reveal both the psychosomatic and the physical effects of local air velocity from an air conditioner using biomarkers which can be collected noninvasively. Salivary α-amylase activity (SAA) and salivary cortisol were used as the indexes of psychosomatic effects. The total protein (TP) collected from stratum corneum was used as an index of the physical condition of dry skin. A continuous experiment over a 5 days period in summer was conducted using 8 healthy you...

  17. Different Modeling Aspects and Energy Systems of Unified Power Quality Conditioner (UPQC): An Overview

    OpenAIRE

    Deshpande, Payal; Shrivastava, Amit; Khare, Anula

    2016-01-01

    Abstract: This paper highlights the classification of Unified Power Quality Conditioner (UPQC) to enhance the electric power quality at distribution levels. It aims to present a broad overview on the different possible UPQC system configurations for single-phase (two-wire) and three-phase (three-wire and four-wire) networks, different modeling approaches and backup energy storages, and recent developments in the field. It is noticed that several researchers have used different names for the U...

  18. Capacity enhancement and flexible operation of unified power quality conditioner in smart and microgrid network

    OpenAIRE

    Khadem, Shafiuzzaman Khan; Basu, Malabika; Conlon, Michael F.

    2018-01-01

    This paper presents a new approach to design Unified Power Quality Conditioner (UPQC), termed as distributed UPQC (D-UPQC), for smart or microgrid network where capacity enhancement and flexible operation of UPQC are the important issues. This paper shows the possibility of capacity enhancement and operational flexibility of UPQC through a coordinated control of existing resources. This UPQC consists of a single unit series active power filter (APFse) and multiple shunt APF (APFsh) units in a...

  19. Physical Properties of Sandy Soil Affected by Soil Conditioner Under Wetting and Drying cycles

    Directory of Open Access Journals (Sweden)

    M.I. Choudhary

    1998-06-01

    Full Text Available Information on the effectiveness of soil conditioners over a prolonged period is scarce. A laboratory experiment was undertaken to evaluate the effectiveness of a polyacrylamide (Broadleaf P4 soil conditioner on the physical properties of sandy soil subjected to wetting and drying cycles. Four concentrations of Broadleaf P4 0, 0.2, 0.4, and 0.6% on dry weight basis were uniformly mixed with a calcareous sandy soil. Addition of Broadleaf P4 to sandy soil increased the water holding capacity, decreased the bulk density, and increased the porosity and void ratio at 0 and 16 wetting and drying cycles. The coefficient of linear extensibility increased considerably with increasing concentrations of the polymer. The addition of polymer at 0 and 16 cycles increased considerably the retention and availability of water in sandy soil. Saturated hydraulic conductivity decreased with increasing concentrations of Broadleaf P4 whereas unsaturated hydraulic conductivity at 0 and 16 cycles showed an increase with increasing soil moisture contents. After I6 wetting and drying cycles, the capacity of the soil to hold water was lost on average by 15.8% when compared to the 0 wetting and drying cycle. The effectiveness of the soil conditioner on bulk density, coefficient of linear extensibility, available water and saturated hydraulic conductivity was reduced on average by 14.1, 24.5, 21.l and 53.7% respectively. The significant changes in soil properties between 0 and 16 cycles suggested that the effectiveness of the conditioner decreased with the application of wetting and drying cycles. However, its effect was still considerable when compared to untreated soil under laboratory conditions.

  20. Band extension in digital methods of transfer function determination – signal conditioners asymmetry error corrections

    Directory of Open Access Journals (Sweden)

    Zbigniew Staroszczyk

    2014-12-01

    Full Text Available [b]Abstract[/b]. In the paper, the calibrating method for error correction in transfer function determination with the use of DSP has been proposed. The correction limits/eliminates influence of transfer function input/output signal conditioners on the estimated transfer functions in the investigated object. The method exploits frequency domain conditioning paths descriptor found during training observation made on the known reference object.[b]Keywords[/b]: transfer function, band extension, error correction, phase errors

  1. Effects of a non-rinse conditioner on the enamel of primary teeth

    Directory of Open Access Journals (Sweden)

    Fava Marcelo

    2003-01-01

    Full Text Available The aim of this in vitro study was to evaluate by scanning electron microscopy the morphological aspects of the enamel of primary teeth after etching with 36% phosphoric acid or a non-rinse conditioner. Ten naturally exfoliated anterior primary teeth were selected. The samples were subjected to prophylaxis with pumice paste and water using a low-speed hand piece. Etching was done on the buccal surface. Specimens were divided into 2 groups: G1 (n=10: etching with 36% phosphoric acid gel - Conditioner 36 (Dentsply for 20 s, followed by water rinse for 15 s; G2 (n=10: etching with NRC - Non Rinse Conditioner (Dentsply for 20 s, followed by air drying for 15 s. The samples were dehydrated, mounted on metal stubs, coated with gold and observed with Jeol JSM-6100 scanning electron microscope. Electron-micrographic analysis showed that both etching agents were effective for etching the enamel of primary teeth causing the formation of microporosities on the enamel surface, although the etching pattern was more effective with the use of 36% phosphoric acid gel.

  2. Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion

    Science.gov (United States)

    Tuthill, Richard Sterling; Bechtel, II, William Theodore; Benoit, Jeffrey Arthur; Black, Stephen Hugh; Bland, Robert James; DeLeonardo, Guy Wayne; Meyer, Stefan Martin; Taura, Joseph Charles; Battaglioli, John Luigi

    2002-01-01

    A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

  3. Air conditioner operation behaviour based on students' skin temperature in a classroom.

    Science.gov (United States)

    Song, Gook-Sup; Lim, Jae-Han; Ahn, Tae-Kyung

    2012-01-01

    A total of 25 college students participated in a study to determine when they would use an air conditioner during a lecture in a university classroom. The ambient temperature and relative humidity were measured 75 cm above the floor every minute. Skin temperatures were measured every minute at seven points, according to the recommendation of Hardy and Dubois. The average clothing insulation value (CLO) of subjects was 0.53 ± 0.07 CLO. The mean air velocity in the classroom was 0.13 ± 0.028 m/s. When the subjects turned the air conditioner both on and off, the average ambient temperatures, relative humidity and mean skin temperatures were 27.4 and 23.7 °C (p = 0.000), 40.9 and 40.0% (p = 0.528) and 32.7 and 32.2 °C (p = 0.024), respectively. When the status of the air conditioner was changed, the differences of skin temperatures in core body parts (head, abdomen and thigh) were not statistically significant. However, in the extremities (mid-lower arm, hand, shin and instep), the differences were statistically significant. Subjects preferred a fluctuating environment to a constant temperature condition. We found that a changing environment does not affect classroom study. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  4. The effect of sealer and water storage on permanent deformation of a tissue conditioner

    Directory of Open Access Journals (Sweden)

    Rafael Leonardo Xediek Consani

    2008-01-01

    Full Text Available When they are used to treat inflamed, irritated, or distorted tissues or in implant therapy, tissue conditioners are required to function over relatively long time periods. Purpose: This in vitro study evaluated the effect of sealer and water storage on permanent deformation one tissue conditioner. Material and methods: Sixty cylindrically-shaped specimens (12.7-mm diameter 3 19.0-mm height were used for the deformation tests. Specimens were divided into 6 test groups (n=10, according to surface treatment (sealer application and water storage (1 hour, 1 week and 2 weeks. Permanent deformation, expressed as a percent (%, was determined using ADA specification no. 18. Data were examined a analysis of variance and a Mann-Whitney test (a= 0.05. Results: Significant differences were observed only after 1 week of water storage, for both groups. The surface treated group presented the highest permanent deformation percentage. Conclusions: This in vitro study indicated that the tissue conditioner evaluated is only useful for 1 week. After this period, the material must be replaced.

  5. Performance curves of room air conditioners for building energy simulation tools

    International Nuclear Information System (INIS)

    Meissner, José W.; Abadie, Marc O.; Moura, Luís M.; Mendonça, Kátia C.; Mendes, Nathan

    2014-01-01

    Highlights: • Experimental characteristic curves for two room air conditioners are presented. • These results can be implemented in building simulation codes. • The energy consumption under different conditions can numerically determine. • The labeled higher energy efficiency product not always provides the best result. - Abstract: In order to improve the modeling of air conditioners in building simulation tools, the characteristic curves for total cooling capacity, sensible cooling capacity and energy efficiency ratio of two room units were determined. They were obtained by means of standard capacity tests on climatic chambers in a set of environmental conditions described by external dry- and internal wet bulb temperatures. Afterward, the performance of these two units and that of four other units, with and without taking into to account the thermodynamic variations of the surrounding environments on it, were compared using a whole building simulation program for simulating a conditioned space. The comparative analysis showed that the air conditioner with the higher energy efficiency rating not always provides the lowest power consumption in real conditions of use

  6. Starting and stopping control on power conditioner in photovoltaic power system; Taiyoko hatsuden system ni okeru power conditioner no kido teishi seigyo ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Hirose, M.; Ishihara, Y.; Todaka, T.; Harada, K. [Doshisha University, Kyoto (Japan); Oshiro, H.; Nakamura, H. [Japan Quality Assurance Organization, Tokyo (Japan)

    1997-11-25

    Studies are made about the control of the power conditioner over the maximum power point tracking (MPPT) function in a photovoltaic power generation system. The analysis is conducted by means of computer simulation into the effect of a start/stop function added to the control of MPPT and the effect on the generation of power of the setting of parameters in the start/stop function. The reduction in output power due to difference between the actual operation point and the optimum operation point is evaluated by use of a load matching correction factor. In this simulation, it is assumed that the solar cell array consists of 13 rows in 5 parallel columns, is capable of a normal output of 3.149kW, has a panel tilted at 30 degrees, and faces due south. The power conditioner is assumed to be a system rated at 3kVA, equipped with system interconnection and back flow features. As a result, it is learned that the stop voltage should be set at 180V or lower and the steady voltage near 185.5V for a good result and that there is not much need after all for the start/stop technique. 2 refs., 8 figs., 2 tabs.

  7. Induced AC voltages on pipelines may present a serious hazard

    International Nuclear Information System (INIS)

    Kirkpatrick, E.L.

    1997-01-01

    The problem of induced AC voltages on pipelines has always been with us. Early pipeline construction consisted of bare steel or cast iron pipe, which was very well grounded. Bell and spigot, mechanical, or dresser-style joint couplings often were used, creating electrically discontinuous pipelines which are less susceptible to AC induction. Although induced AC affects any pipeline parallel to a high-voltage alternating current (HVAC) power line, the effects were not noticeable on bare pipelines. With the advent of welded steel pipelines, modern cathodic protection (CP) methods and materials, and the vastly improved quality of protective coatings, induced AC effects on pipelines have become a significant consideration on many pipeline rights-of-way. In the last two to three decades, one has been seeing much more joint occupancy of the same right-of-way by one or more pipelines and power lines. As the cost of right-of-way and the difficulty in acquisition, particularly in urban areas, have risen, the concept of joint occupancy rights-of-way has become more attractive to many utility companies. Federal and state regulations usually insist on joint-use right-of-way when a utility proposes crossing regulated or publicly owned lands, wherever there is an existing easement. Such joint use allows the induced AC phenomena to occur and may create electrical hazards and interference to pipeline facilities. Underground pipelines are especially susceptible if they are well-coated and electrically isolated for CP

  8. Hopping models and ac universality

    DEFF Research Database (Denmark)

    Dyre, Jeppe; Schrøder, Thomas

    2002-01-01

    Some general relations for hopping models are established. We proceed to discuss the universality of the ac conductivity which arises in the extreme disorder limit of the random barrier model. It is shown that the relevant dimension entering into the diffusion cluster approximation (DCA) is the h......Some general relations for hopping models are established. We proceed to discuss the universality of the ac conductivity which arises in the extreme disorder limit of the random barrier model. It is shown that the relevant dimension entering into the diffusion cluster approximation (DCA......) is the harmonic (fracton) dimension of the diffusion cluster. The temperature scaling of the dimensionless frequency entering into the DCA is discussed. Finally, some open problems regarding ac universality are listed....

  9. Autonomous Operation of a Hybrid AC/DC Microgrid with Multiple Interlinking Converters

    DEFF Research Database (Denmark)

    Peyghami, Saeed; Mokhtari, Hossein; Blaabjerg, Frede

    2018-01-01

    Applying conventional dc-voltage based droop approaches for hybrid ac/dc microgrids interconnected by a single interlinking converter (IC) can properly manage the power flow among ac and dc subgrids. However, due to the effect of line resistances, these approaches may create a circulating power a...

  10. Nuclear structure of 231Ac

    International Nuclear Information System (INIS)

    Boutami, R.; Borge, M.J.G.; Mach, H.; Kurcewicz, W.; Fraile, L.M.; Gulda, K.; Aas, A.J.; Garcia-Raffi, L.M.; Lovhoiden, G.; Martinez, T.; Rubio, B.; Tain, J.L.; Tengblad, O.

    2008-01-01

    The low-energy structure of 231 Ac has been investigated by means of γ ray spectroscopy following the β - decay of 231 Ra. Multipolarities of 28 transitions have been established by measuring conversion electrons with a MINI-ORANGE electron spectrometer. The decay scheme of 231 Ra → 231 Ac has been constructed for the first time. The Advanced Time Delayed βγγ(t) method has been used to measure the half-lives of five levels. The moderately fast B(E1) transition rates derived suggest that the octupole effects, albeit weak, are still present in this exotic nucleus

  11. Analysis of noise lines in the Virgo C7 data

    International Nuclear Information System (INIS)

    Acernese, F; Amico, P; Alshourbagy, M

    2007-01-01

    The paper presents a description of the work of detection and identification of frequency lines in the Virgo dark fringe data from run C7. A number of methods are highlighted by which noise frequency lines are detected by data analysis and measurements in the laboratory. In this paper we give a description of the list of noise line candidates provided by the pulsar search analysis, the investigation of 10 Hz (and harmonics) noise, violin modes, noise from the end station buildings' air conditioners, sidebands in calibration lines and aliasing in the 4 kHz reconstructed data

  12. Analysis of noise lines in the Virgo C7 data

    Energy Technology Data Exchange (ETDEWEB)

    Acernese, F [INFN, Sezione di Napoli and/or Universita di Napoli ' Federico II' Complesso Universitario di Monte S Angelo, and/or Universita di Salerno, Fisciano (Italy); Amico, P [INFN, Sezione di Perugia and/or Universita di Perugia, Perugia (Italy); Alshourbagy, M [INFN, Sezione di Pisa and/or Universita di Pisa, Pisa (Italy)] (and others)

    2007-10-07

    The paper presents a description of the work of detection and identification of frequency lines in the Virgo dark fringe data from run C7. A number of methods are highlighted by which noise frequency lines are detected by data analysis and measurements in the laboratory. In this paper we give a description of the list of noise line candidates provided by the pulsar search analysis, the investigation of 10 Hz (and harmonics) noise, violin modes, noise from the end station buildings' air conditioners, sidebands in calibration lines and aliasing in the 4 kHz reconstructed data.

  13. Influence of environmental characteristics and climatic factors on mites in the dust of air-conditioner filters.

    Science.gov (United States)

    Wu, J; Liu, Z G; Ran, P X; Wang, B

    2009-12-01

    To investigate mites in the dust of air-conditioner filters (MACF) in China, a total of 652 dust samples were collected from six cities: Guangzhou (n = 129), Nanchang (n = 127), Shanghai (n = 113), Xian (n = 93), Beijing (n = 93), and Shenyang (n = 79). Tarsonemus granarius was the most dominant species (87.2%). Dermatophagoides pteronyssinus and Dermatophagoides farinae only represented 7.0 and 3.0% of total mites, respectively. With latitude increasing, both mite occurrence rate (P air-conditioner age, utilization time and power. Wall and window type air-conditioner had higher risk of finding MACF than the floor type air-conditioner. As far as the cleaning interval time of ACF was concerned, higher risk ratio and the highest density of MACF were found in the time stage of >3, air-conditioner filters are potential indoor threat to asthma and allergy sufferers. In this study, we find that the storage mite Tarsonemus granarius is the predominant species of mites in the dust of air-conditioner filters (MACF). Thus, the possible clinical importance of T. granarius should cause more our attentions in the future. The abundance and distribution of MACF are also found significantly varied in different climatic regions of China. When we try to assess the possible risk of MACF, more attentions should be focused on subtropical region than temperate region. The influence analysis of environmental characteristics on the prevalence of MACF will shed light on the establishment of mite control strategy and the design of mite defense air-conditioner.

  14. AC ignition of HID lamps

    NARCIS (Netherlands)

    Sobota, A.; Kanters, J.H.M.; Manders, F.; Veldhuizen, van E.M.; Haverlag, M.

    2010-01-01

    Our aim was to examine the starting behaviour of mid-pressure argon discharges in pin-pin (point-to-point) geometry, typically used in HID lamps. We focused our work on AC ignition of 300 and 700 mbar Ar discharges in Philips 70W standard burners. Frequency was varied between 200 kHz and 1 MHz. In

  15. A nonlinear model for AC induced corrosion

    Directory of Open Access Journals (Sweden)

    N. Ida

    2012-09-01

    Full Text Available The modeling of corrosion poses particular difficulties. The understanding of corrosion as an electrochemical process has led to simple capacitive-resistive models that take into account the resistance of the electrolytic cell and the capacitive effect of the surface potential at the interface between conductors and the electrolyte. In some models nonlinear conduction effects have been added to account for more complex observed behavior. While these models are sufficient to describe the behavior in systems with cathodic protection, the behavior in the presence of induced AC currents from power lines and from RF sources cannot be accounted for and are insufficient to describe the effects observed in the field. Field observations have shown that a rectifying effect exists that affects the cathodic protection potential and this effect is responsible for corrosion in the presence of AC currents. The rectifying effects of the metal-corrosion interface are totally missing from current models. This work proposes a nonlinear model based on finite element analysis that takes into account the nonlinear behavior of the metal-oxide interface and promises to improve modeling by including the rectification effects at the interface.

  16. Calculation of single phase AC and monopolar DC hybrid corona effects

    International Nuclear Information System (INIS)

    Zhao, T.; Sebo, S.A.; Kasten, D.G.

    1996-01-01

    Operating a hybrid HVac and HVdc line is an option for increasing the efficiency of power transmission and overcoming the difficulties in obtaining a new right-of-way. This paper proposes a new calculation method for the study of hybrid line corona. The proposed method can be used to calculate dc corona losses and corona currents in dc or ac conductors for single phase ac and monopolar dc hybrid lines. Profiles of electric field strength and ion current density at ground level can be estimated. The effects of the presence of an energized ac conductor on dc conductor corona and dc voltage on ac conductor corona are included in the method. Full-scale and reduced-scale experiments were utilized to investigate the hybrid line corona effects. Verification of the proposed calculation method is given

  17. Performance test of a grid-tied PV system to power a split air conditioner system in Surabaya

    Science.gov (United States)

    Tarigan, E.

    2017-11-01

    Air conditioner for cooling air is one of the major needs for those who live in hot climate area such as Indonesia. This work presents the performance test of a grid-tied PV system to power air conditioner under a hot tropical climate in Surabaya, Indonesia. A 800 WP grid-tied photovoltaic (PV) system was used, and its performance was tested to power a 0.5 pk of split air conditioner system. It was found that about 3.5 kWh daily energy was consumed by the tested air conditioner system, and about 80% it could be supplied from the PV system. While the other 20% was supplied by the grid during periods of low solar irradiation, 440 Wh of energy was fed into the grid during operation out of office hours. By using the grid-tied PV system, the energy production by PV system did not need to match the consumption of the air conditioner. However, a larger capacity of PV system would mean that a higher percentage of the load would be covered by PV system.

  18. On the Application of TLS Techniques to AC Electrical Drives

    Directory of Open Access Journals (Sweden)

    M. Cirrincione

    2005-03-01

    Full Text Available This paper deals with the application of a new neuron, the TLS EXIN neuron, to AC induction motor drives. In particular, it addresses two important subjects of AC induction motor drives: the on-line estimation of the electrical parameters of the machine and the speed estimation in sensorless drives. On this basis, this work summarizes the parameter estimation and sensorless techniques already developed by the authors over these last few years, all based on the TLS EXIN. With regard to sensorless, two techniques are proposed: one based on the MRAS and the other based on the full-order Luenberger observer. The work show some of the most significant results obtained by the authors in these fields and stresses the important potentiality of this new neural technique in AC induction machine drives.

  19. AcEST: DK954361 [AcEST

    Lifescience Database Archive (English)

    Full Text Available in 5-4 OS=Homo sap... 33 1.1 sp|Q9DBY1|SYVN1_MOUSE E3 ubiquitin-protein ligase synoviolin OS=... 33 1.4 sp|Q...86TM6|SYVN1_HUMAN E3 ubiquitin-protein ligase synoviolin OS=... 33 1.4 sp|O55188|DMP1_MOUSE Dentin matrix ac

  20. Planning aspects of ac extra high voltage lines

    Energy Technology Data Exchange (ETDEWEB)

    Engelhardt, H

    1964-01-01

    The technical points arising in any project for application of higher voltages on power grids in Europe are discussed. The cost aspects of two alternative ways of extending the voltage level of existing systems are discussed in detail. The short-circuit current in a high-power system with isolated or grounded neutral point and its relation to the mode of grounding is examined. For a transmission distance of 200 kVm, operating cost for each kWh transmitted are shown on curves for voltages of 220, 380 and 700 kV against transmitted energy. This shows that for any rated voltage there is a range of energy values which can be transmitted economically. Factors to be considered in maintaining, selecting or rejecting transformers and switchgear of other systems for higher voltage purposes are mentioned.

  1. Noninvasive evaluation of the chronic influence of local air velocity from an air conditioner using salivary cortisol and skin caspase-14 as biomarkers of psychosomatic and environmental stress.

    Science.gov (United States)

    Yamaguchi, M; Nishimiya, H

    2012-01-01

    To demonstrate the possibility of evaluating the chronic influence of local air velocity from an air conditioner using noninvasive biomarkers. Over a consecutive 5-day period, 16 healthy young male adults were exposed to air flow from a whole ceiling-type air conditioner (low local air velocity) and from a commercial concentrated exhaust air conditioner (high local air velocity). Salivary cortisol was used as an index of the psychological effects and caspase-14, collected from the stratum corneum, was used as a marker of environmental stress on the skin. Local air velocity generated from the whole ceiling-type air conditioner where the subject's head was positioned was one-seventh that of the exhaust air conditioner. After exposure to the exhaust air conditioner for 5 days, salivary cortisol decreased significantly from morning to evening and skin caspase-14 gradually increased during the day. A significant increase in hydration index from the morning to the evening was found with the whole ceiling-type air conditioner. The effects of chronic exposure to air movement generated by an air conditioner may be quantified by measurement of salivary cortisol and skin caspase-14.

  2. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building

    Energy Technology Data Exchange (ETDEWEB)

    Ni Honggang; Cao Shanping; Chang Wenjing [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Zeng Hui, E-mail: huizeng0608@gmail.com [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Department of Ecology, College of Urban and Environmental Sciences, Peking University, Beijing 100871 (China)

    2011-07-15

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM{sub 2.5} (Particulate Matter up to 2.5 {mu}m in size) bounded {Sigma}{sub 15}PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM{sub 10} (Particulate Matter up to 10 {mu}m in size) bounded {Sigma}{sub 15}PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of {Sigma}{sub 15}PBDEs via dust inhalation and ingestion for adults reached {approx}141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. - Highlights: > Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than that in the old ones. > PBDE emissions from indoor sources can be expected to continue for a long time as the PBDE-containing products in offices were to be kept many years. > The household consumer products, especially computers, are the main sources of PBDEs in central air conditioner filter dust. > Further studies are needed to fully understand the emission mechanism of PBDE from indoor consumer products. - PBDEs in central air conditioner filter dust from a new building were investigated

  3. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building

    International Nuclear Information System (INIS)

    Ni Honggang; Cao Shanping; Chang Wenjing; Zeng Hui

    2011-01-01

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM 2.5 (Particulate Matter up to 2.5 μm in size) bounded Σ 15 PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM 10 (Particulate Matter up to 10 μm in size) bounded Σ 15 PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of Σ 15 PBDEs via dust inhalation and ingestion for adults reached ∼141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. - Highlights: → Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than that in the old ones. → PBDE emissions from indoor sources can be expected to continue for a long time as the PBDE-containing products in offices were to be kept many years. → The household consumer products, especially computers, are the main sources of PBDEs in central air conditioner filter dust. → Further studies are needed to fully understand the emission mechanism of PBDE from indoor consumer products. - PBDEs in central air conditioner filter dust from a new building were investigated

  4. Analysis for SEER of variable speed room air conditioner in China. Paper no. IGEC-1-104

    International Nuclear Information System (INIS)

    Yitai, M.; Shengchun, L.; Lirong, M.

    2005-01-01

    In this paper, the calculation method for seasonal energy efficiency ratio (SEER) given in Standard JRA4046-1999 is analyzed and further modified. Based on temperature zone map of U.S., Japan and China and detailed weather data of eight Chinese cities in last 30 years, regional seasonal energy efficiency ratio (RSEER) and energy saving percentage of variable speed room air conditioner are analyzed and compared with various geographical regions in China. It is concluded that RSEER presents the associated effect of season, climate and geography, and therefore should be taken as an evaluation standard for room air conditioner, especially variable speed room air conditioner. Experimental measurements are conducted in the analysis to investigate the effect of energy efficiency ratio (EER) on the improvement of energy saving percentage and SEER. (author)

  5. Comparative analysis of objective techniques for criteria weighing in two MCDM methods on example of an air conditioner selection

    Directory of Open Access Journals (Sweden)

    Vujičić Momčilo D.

    2017-01-01

    Full Text Available This paper deals with comparative analysis of two different types of objective techniques for criteria weighing: Entropy and CRITIC and two MCDM methods: MOORA and SAW on example of an air conditioner selection. We used six variants for calculation of normalized performance ratings. Results showed that the decision of the best air conditioner was basically independent of the MCDM method used, despite the applied technique for determination of criteria weights. Complete ranking within all of the combinations of methods and techniques with diverse ratio calculation variants showed that the best ranked air conditioner was A7, while the worst ones were A5 and A9. Significant positive correlation was obtained for almost all the pairs of variants in all the combinations except for the MOORA - CRITIC combination with SAW - Entropy combination to have the highest correlations between variants (p < 0.01.

  6. Compressor motor for air conditioners realizing high efficiency and low cost; Kokoritsu tei cost wo jitsugenshita eakonyo asshukuki motor

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, Y.; Kawamura, K.; Imazawa, K. [Toshiba Corp., Tokyo (Japan)

    2000-01-01

    The compressor motor accounts for most of the consumption of electric power in an air conditioner. To promote energy-saving, Toshiba has been progressively changing the compressor motors in its air conditioners to high-efficiency brushless DC motors. We have now developed a new compressor motor in order to achieve even greater energy-saving. A concentrated winding system was adopted featuring direct winding on the teeth of the stator core, for the first time in the industry. As a result, it was possible to realize a high-efficiency, compact, lightweight, and low-cost motor. Moreover, by constructing a new system for production, we were able to improve productivity and quality. The newly developed motor is expected to contribute to the further diffusion of energy-saving air conditioners. (author)

  7. Aperture measurements with AC dipole

    CERN Document Server

    Fuster Martinez, Nuria; Dilly, Joschua Werner; Nevay, Laurence James; Bruce, Roderik; Tomas Garcia, Rogelio; Redaelli, Stefano; Persson, Tobias Hakan Bjorn; CERN. Geneva. ATS Department

    2018-01-01

    During the MDs performed on the 15th of September and 29th of November 2017, we measured the LHC global aperture at injection with a new AC dipole method as well as using the Transverse Damper (ADT) blow-up method used during the 2017 LHC commissioning for benchmarking. In this note, the MD procedure is presented as well as the analysis of the comparison between the two methods. The possible benefits of the new method are discussed.

  8. Optimum dry-cooling sub-systems for a solar air conditioner

    Science.gov (United States)

    Chen, J. L. S.; Namkoong, D.

    1978-01-01

    Dry-cooling sub-systems for residential solar powered Rankine compression air conditioners were economically optimized and compared with the cost of a wet cooling tower. Results in terms of yearly incremental busbar cost due to the use of dry-cooling were presented for Philadelphia and Miami. With input data corresponding to local weather, energy rate and capital costs, condenser surface designs and performance, the computerized optimization program yields design specifications of the sub-system which has the lowest annual incremental cost.

  9. The Performance of a Desiccant-Based air Conditioner on a Florida School

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J.

    2001-08-22

    Indoor air quality has become a major public health issue in recent years. ASHRAE standard 62-1989-which is an attempt to improve indoor air quality by increasing building ventilation rates-greatly increases the latent loads on many buildings. In more humid climates, the Sensible Heat Ratio (SHR) of a building's air conditioner (which is the fraction of total delivered cooling that is sensible) is too high to meet the existing latent loads. The implementation of ASHRAE 62-1989 will only exacerbate this problem.

  10. Select Components and Finish System Design of a Window Air Conditioner with Propane

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-01

    This report describes the technical targets for developing a high efficiency window air conditioner (WAC) using propane (R-290). The baseline unit selected for this activity is a GE R-410A WAC. We established collaboration with a Chinese rotary compressor manufacturer, to select an R-290 compressor. We first modelled and calibrated the WAC system model using R-410A. Next, we applied the calibrated system model to design the R-290 WAC, and decided the strategies to reduce the system charge below 260 grams and achieve the capacity and efficiency targets.

  11. Evaluation of a clay-based acidic bedding conditioner for dairy cattle bedding.

    Science.gov (United States)

    Proietto, R L; Hinckley, L S; Fox, L K; Andrew, S M

    2013-02-01

    This study investigated the effects of a clay-based acidic bedding conditioner on sawdust bedding pH, dry matter (DM), environmental pathogen counts, and environmental bacterial counts on teat ends of lactating dairy cows. Sixteen lactating Holstein cows were paired based on parity, days in milk, milk yield, and milk somatic cell count, and were negative for the presence of an intramammary pathogen. Within each pair, cows were randomly assigned to 1 of 2 treatments with 3-wk periods in a crossover design. Treatment groups consisted of 9 freestalls per group bedded with either untreated sawdust or sawdust with a clay-based acidic bedding conditioner, added at 3- to 4-d intervals over each 21-d period. Bedding and teat ends were aseptically sampled on d 0, 1, 2, 7, 14, and 21 for determination of environmental bacterial counts. At the same time points, bedding was sampled for DM and pH determination. The bacteria identified in the bedding material were total gram-negative bacteria, Streptococcus spp., and coliform bacteria. The bacteria identified on the teat ends were Streptococcus spp., coliform bacteria, and Klebsiella spp. Teat end score, milk somatic cell count, and intramammary pathogen presence were measured weekly. Bedding and teat cleanliness, environmental high and low temperatures, and dew point data were collected daily. The bedding conditioner reduced the pH, but not the DM, of the sawdust bedding compared with untreated sawdust. Overall environmental bacterial counts in bedding were lower for treated sawdust. Total bacterial counts in bedding and on teat ends increased with time over both periods. Compared with untreated sawdust, the treated bedding had lower counts of total gram-negative bacteria and streptococci, but not coliform counts. Teat end bacterial counts were lower for cows bedded on treated sawdust for streptococci, coliforms, and Klebsiella spp. compared with cows bedded on untreated sawdust. The clay-based acidic bedding conditioner

  12. Experimental study on split air conditioner with new hybrid equipment of energy storage and water heater all year round

    International Nuclear Information System (INIS)

    Wang Shaowei; Liu Zhenyan; Li Yuan; Zhao Keke; Wang Zhigang

    2005-01-01

    This paper presents a split air conditioner with a new hybrid equipment of energy storage and water heater all year round (ACWES). The authors made a special design on the storage tank to adjust the refrigerant capacity in the storage coils under different functions, instead of adding an accumulator to the system. An ACWES prototype, rebuilt from an original split air conditioner, has been finished, and experimental study of the operation processes of the prototype was done from which some important conclusions and suggestions have been made, which were helpful in the primary design and improvement of an ACWES system for potential users

  13. Security analysis of interconnected AC/DC systems

    DEFF Research Database (Denmark)

    Eriksson, Robert

    2015-01-01

    This paper analyses N-1 security in an interconnected ac/dc transmission system using power transfer distribution factors (PTDFs). In the case of a dc converter outage the power needs to be redistributed among the remaining converter to maintain power balance and operation of the dc grid...... any line or transformer limits. Simulations were performed in a model of the Nordic power system where a dc grid is placed on top. The simulation supports the method as a tool to consider transfer limits in the grid to avoid violate the same and increase the security after a converter outage........ The redistribution of power has a sudden effect on the power-flow in the interconnected ac system. This may cause overloading of lines and transformers resulting in disconnection of equipment, and as a consequence cascading failure. The PTDF is used as a method to analyze and avoid violating limits by in the dc...

  14. Numerical and Physical Parametric Analysis of a SEN with Flow Conditioners in Slab Continuous Casting Mold

    Directory of Open Access Journals (Sweden)

    Gonzalez-Trejo J.

    2017-06-01

    Full Text Available Some of the most recent technologies that improves the performance in continuous casting process has installed infrastructure outside the mold to modify the natural fluid flow pattern to obtain a quasi-steady condition and promote a uniform solidified shell of steel. The submerged entry nozzle distributes the liquid steel in the mold and can be used to obtain the flow symmetry condition with external geometry improvements. The fluid flow conditioners were located near the outlet ports of the nozzle. The aim of the modifiers is to impose a pseudo symmetric pattern in the upper zone of the mold by inhibiting the fluid exchange between the zones created by conditioners. This work evaluates the effect of the thickness and length of the fluid-flow modifiers on the overall performance of the submerged nozzle. These properties of the fluid-flow modifiers were normalized based on two of the geometric dimensions of the standard equipment. Numerical and physical simulations suggest that the flow modifier should be as thin as possible.

  15. Small fan assisted air conditioner for thermal comfort and energy saving in Thailand

    International Nuclear Information System (INIS)

    Atthajariyakul, Surat; Lertsatittanakorn, Charoenporn

    2008-01-01

    From the fact that Thai people have a tolerance to high air temperature and are accustomed to high air movement from electric fans in non-air conditioned space, this paper proposes the use of small fan assisted air conditioners for human thermal comfort and energy saving in Thailand. In the study, a total 15 students were tested in a 2.5 x 3.5 x 2.5 m 3 test room equipped with a 12,000 Btu/h split type air conditioner. During the tests, the room air temperature was varied from 25, 26, 27 and 28 deg. C every 1 h. A small fan with 15 cm diameter was placed in front of each subject. In each hour, the small fan was varied to supply a small area with velocity from 0.2, 0.5, 1, 1.5 and 2 m/s. In each condition, the subjects were asked to vote for their thermal sensation. The results showed that the temperature set point could be increased up to 28 deg. C when a small fan was used to supply local air velocity from 0.5 to 2 m/s according to individual preference. This would reduce the electricity consumption of the air conditioning unit. According to the proposed method, this can save energy for office buildings in the commercial sector as high as 1959.51 GWh/year

  16. Numerical Analysis and Geometry Optimisation of Vertical Vane of Room Air-conditioner

    Directory of Open Access Journals (Sweden)

    Al-Obaidi Abdulkareem Sh. Mahdi

    2018-01-01

    Full Text Available Vertical vanes of room air-conditioners are used to control and direct cold air. This paper aims to study vertical vane as one of the parameters that affect the efficiency of dissipating cold air to a given space. The vertical vane geometry is analysed and optimised for lower production cost using CFD. The optimised geometry of the vertical vane should have the same or increased efficiency of dissipating cold air and have lesser mass compared to the existing original design. The existing original design of vertical vane is simplified and analysed by using ANSYS Fluent. Efficiency of wind direction is define as how accurate the direction of airflow coming out from vertical vane. In order to calculate the efficiency of wind direction, 15° and 30° rotation of vertical vane inside room air-conditioner are simulated. The efficiency of wind direction for 15° rotation of vertical vane is 57.81% while efficiency of wind direction for 30° rotation of vertical vane is 47.54%. The results of the efficiency of wind direction are used as base reference for parametric study. The parameters investigated for optimisation of vertical vane are focused at length of long span, tip chord and short span. The design of 15% decreased in vane surface area at tip chord is the best optimised design of vertical vane because the efficiency of wind direction is the highest as 60.32%.

  17. Applying water cooled air conditioners in residential buildings in Hong Kong

    International Nuclear Information System (INIS)

    Chen Hua; Lee, W.L.; Yik, F.W.H.

    2008-01-01

    The objective of this study is to conduct a realistic prediction of the potential energy saving for using water cooled air conditioners in residential buildings in Hong Kong. A split type air conditioner with air cooled (AAC) and water cooled (WAC) options was set up for experimental study at different indoor and outdoor conditions. The cooling output, power consumption and coefficient of performance (COP) of the two options were measured and calculated for comparison. The experimental results showed that the COP of the WAC is, on average, 17.4% higher than that of the AAC. The results were used to validate the mathematical models formulated for predicting the performance of WACs and AACs at different operating conditions and load characteristics. While the development of the mathematical models for WACs was reported in an earlier paper, this paper focuses on the experimental works for the AAC. The mathematical models were further used to predict the potential energy saving for application of WACs in residential buildings in Hong Kong. The predictions were based on actual building developments and realistic operating characteristics. The overall energy savings were estimated to be around 8.7% of the total electricity consumption for residential buildings in Hong Kong. Wider use of WACs in subtropical cities is, therefore, recommended

  18. A Proposal for the Time Domain Modeling of Split Air Conditioners for Consumer Reimbursement Studies

    Science.gov (United States)

    Rezende, Paulo Henrique Oliveira; Almeida Junior, Afonso Bernardino; Gondim, Isaque Nogueira; Oliveira, José Carlos

    2015-04-01

    This paper deals with computer application procedures for the evaluation of the causal consistency between anomalous phenomena manifested in electrical networks, along with the physical damage associated with electrical equipment and possible reimbursement requests. The focus is on the development of an air conditioner appliance model of the type known as split founded upon a representation, in the time domain, in accordance with the Alternative Transients Program (ATP) simulator requirements. This approach permits investigations concerning the performance of the product when submitted to ideal and non-ideal supply conditions. Once the equipment model is implemented in the program, a set of investigative studies are carried out to show the device performance under specific energy quality disturbance conditions. In addition, there are still the results for the validation of the process established through the correlation between computational performance of the air conditioner with corresponding studies carried out experimentally, which are presented herein. Moreover, once the effectiveness of the developed model is verified, it is implemented into the Requests for Reimbursement Software. Investigations related to the correlation between disturbances and the levels of thermal and dielectric tolerance are then performed aiming at illustrating the use of the research results for the reimbursement analyzes purposes.

  19. Simultaneous distribution of AC and DC power

    Science.gov (United States)

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  20. Performance of AC/graphite capacitors at high weight ratios of AC/graphite

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hongyu [IM and T Ltd., Advanced Research Center, Saga University, 1341 Yoga-machi, Saga 840-0047 (Japan); Yoshio, Masaki [Advanced Research Center, Department of Applied Chemistry, Saga University, 1341 Yoga-machi, Saga 840-0047 (Japan)

    2008-03-01

    The effect of negative to positive electrode materials' weight ratio on the electrochemical performance of both activated carbon (AC)/AC and AC/graphite capacitors has been investigated, especially in the terms of capacity and cycle-ability. The limited capacity charge mode has been proposed to improve the cycle performance of AC/graphite capacitors at high weight ratios of AC/graphite. (author)

  1. [A patient with acute hypersensitivity pneumonitis with a diagnosis of air-conditioner lung, who responded to therapy].

    Science.gov (United States)

    Ishikawa, Rie; Kamiya, Hiroyuki; Ikushima, Souichiro; Oristu, Masaru; Takemura, Tamiko

    2010-02-01

    The patient was a 48-year-old woman and current smoker. In May 2007, she moved to a new residence. In the middle of the following month, she developed acute respiratory distress and a fever (38 degrees C) after running her air conditioner continuously throughout the night. The chest X-ray film showed diffuse infiltrative shadows in the middle and lower lung fields. After hospital admission, her oxygenation improved without treatment and the infiltrates improved over the clinical course. As a consequence, we suspected hypersensitivity pneumonitis. The bronchoalveolar lavage showed predominant lymphocytes of 72.6%, with a low CD 4/8 ratio of 0.2. Transbronchial lung biopsy findings corresponded to acute hypersensitivity pneumonitis. The results of the environmental challenge test were positive only when her air conditioner was on, resulting, in a diagnosis of air-conditioner lung. Several microorganisms were detected in an environmental sample, but 20 kinds of serum precipitating antibodies were negative on a thorough screening, so no responsible antigen could be identified. The patient's symptoms did not recur after her air conditioner was replaced.

  2. Numerical Study of an Ejector as an Expansion Device in Split-type Air Conditioners for Energy Savings

    Directory of Open Access Journals (Sweden)

    Kasni Sumeru

    2013-07-01

    Full Text Available The present study describes a numerical approach for determining both the motive nozzle and constant-area diameters of an ejector as an expansion device, based on the cooling capacity of a split-type air-conditioner using R290 as refrigerant. Previous studies have shown that replacement of HCFC R22 with HC290 (propane in the air conditioner can improve the coefficient of performance (COP. The purpose of replacing the capillary tube with an ejector as an expansion device in a split-type air conditioner using HC290 is to further improve the COP. In developing the model, conservation laws of mass, momentum and energy equations were applied to each part of the ejector. The numerical results show that the motive nozzle diameter remains constant (1.03 mm under varying condenser temperatures, whereas the diameter of the constant-area decreases as the condenser temperature increases. It was also found that improvement of the COP can reach 32.90% at a condenser temperature of 55 °C. From the results mentioned above, it can be concluded that the use of an ejector can further improve the COP of a split-type air conditioner using HC290 as working fluid.

  3. Experimental Determination of Demand Response Control Models and Cost of Control for Ensembles of Window-Mount Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Geller, Drew Adam [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Backhaus, Scott N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-29

    Control of consumer electrical devices for providing electrical grid services is expanding in both the scope and the diversity of loads that are engaged in control, but there are few experimentally-based models of these devices suitable for control designs and for assessing the cost of control. A laboratory-scale test system is developed to experimentally evaluate the use of a simple window-mount air conditioner for electrical grid regulation services. The experimental test bed is a single, isolated air conditioner embedded in a test system that both emulates the thermodynamics of an air conditioned room and also isolates the air conditioner from the real-world external environmental and human variables that perturb the careful measurements required to capture a model that fully characterizes both the control response functions and the cost of control. The control response functions and cost of control are measured using harmonic perturbation of the temperature set point and a test protocol that further isolates the air conditioner from low frequency environmental variability.

  4. Control strategy for Single-phase Transformerless Three-leg Unified Power Quality Conditioner Based on Space Vector Modulation

    DEFF Research Database (Denmark)

    Lu, Yong; Xiao, Guochun; Wang, Xiongfei

    2016-01-01

    The unified power quality conditioner (UPQC) is known as an effective compensation device to improve PQ for sensitive end-users. This paper investigates the operation and control of a single-phase three-leg UPQC (TL-UPQC), where a novel space vector modulation method is proposed for naturally...

  5. SNS AC Power Distribution and Reliability of AC Power Supply

    CERN Document Server

    Holik, Paul S

    2005-01-01

    The SNS Project has 45MW of installed power. A design description under the Construction Design and Maintenance (CDM) with regard to regulations (OSHA, NFPA, NEC), reliability issues and maintenance of the AC power distribution system are herewith presented. The SNS Project has 45MW of installed power. The Accelerator Systems are Front End (FE)and LINAC KLYSTRON Building (LK), Central Helium Liquefier (CHL), High Energy Beam Transport (HEBT), Accumulator Ring and Ring to Target Beam Transport (RTBT) Support Buildings have 30MW installed power. FELK has 16MW installed, majority of which is klystron and magnet power supply system. CHL, supporting the super conducting portion of the accelerator has 7MW installed power and the RING Systems (HEBT, RING and RTBT) have also 7MW installed power.*

  6. Inhibition of acrolein-stimulated MUC5AC production by fucoidan in human bronchial epithelial cells.

    Science.gov (United States)

    Pokharel, Yuba Raj; Yoon, Se Young; Kim, Sang Kyum; Li, Jian-Dong; Kang, Keon Wook

    2008-10-01

    Fucoidan, a marine sulfated polysaccharide has both antithrombotic and anti-inflammatory effects. We determined the effect of fucoidan on MUC5AC expression in a human bronchial epithelial cell line, NCI-H292. Reverse transcription-polymerase chain reaction (RT-PCR) analysis showed that fucoidan inhibited MUC5AC expression and protein secretion in cells stimulated with acrolein, a toxic aldehyde present in tobacco smoke. The activation of both nuclear factor-kappa B (NF-kappa B) and activator protein 1 (AP-1) are key steps in the transcriptional activation of MUC5AC. We found that the acrolein-mediated transactivation of MUC5AC was selectively dependent on AP-1 activation and was suppressed by fucoidan. Fucoidan-induced AP-1 inhibition and MUC5AC repression might be associated with fucoidan's protective effects against respiratory diseases.

  7. Fixed switching frequency applied in single-phase boost AC to DC converter

    International Nuclear Information System (INIS)

    Chen, T.-C.; Ren, T.-J.; Ou, J.-C.

    2009-01-01

    The fixed switching frequency control for a single-phase boost AC to DC converter to achieve a sinusoidal line current and unity power factor is proposed in this paper. The relation between the line current error and the fixed switching frequency was developed. For a limit line current error, the minimum switching frequency for a boost AC to DC converter can be achieved. The proposed scheme was implemented using a 32-bit digital signal processor TMS320C32. Simulations and experimental results demonstrate the feasibility and fast dynamic response of the proposed control strategy.

  8. Resonance reduction for AC drives with small capacitance in the DC link

    DEFF Research Database (Denmark)

    Máthé, Lászlo; Török, Lajos; Wang, Dong

    2016-01-01

    Pulse Width Modulated AC drives equipped with small DC-link capacitor are becoming an attractive solution for electric drive applications with moderate requirements for shaft dynamic performance. However, when these drives are fed from a weak grid a resonance between the line side impedance...... and the DC-link capacitor appears. Due to this resonance, the THD and the partially weighted harmonic distortion of the line currents are increased, which may rise compatibility problems with the AC line harmonic standards. By using vector control the motor drive is transformed into a constant power load...

  9. Simulated and experimental performance of split packaged air conditioner using refrigerant HC-290 as a substitute for HCFC-22

    International Nuclear Information System (INIS)

    Padalkar, Atul S.; Mali, Kundlik V.; Devotta, Sukumar

    2014-01-01

    This paper discusses the use of propane (HC-290) as a safe and energy efficient alternative to HCFC-22 in a typical split air conditioner with nominal cooling capacities up to 5.1 kW. Initially split air conditioner performance is simulated for cooling capacity, energy efficiency ratio (EER), and refrigerant charge. Tests were conducted for different test cases in a psychrometric test chamber with HCFC-22 and HC-290. The test conditions considered are as per Indian Standards, IS 1391 (1992) Part I. The various parameters considered were based on simulated performance with the objective to achieve maximum EER for the desired cooling capacity. As the flammability is an issue for HC-290, the reduction of HC-290 charge was another objective. Two different types of condensers, first with smaller size tubing and another parallel flow condenser (PFC) or minichannel condenser were used in order to reduce HC-290 charge. For HC-290, the highest EER achieved was 3.7 for cooling capacity 4.90 kW for a refrigerant charge of 360 g. The important safety aspects of using HC-290 in air conditioner are discussed. The refrigerant charge as per EN 378 for different cooling capacities and room sizes is also considered. -- Highlights: • Simulation for performance of split air conditioner has been done using HC-290 as a replacement to HCFC-22. • The safety aspects of HC-290 are discussed when used in split air conditioner. • HC-290 was tested in psychrometric test chamber as per IS 1391 part 1. • With PFC, HC-290 gave highest EER of 3.7 which was 37% higher than that of HCFC-22. • The lowest HC-290 charge used in test was 340 g which is well below LFL

  10. Energy efficiency and energy saving air conditioners window and split type; Eficiencia energetica e economia de energia de condicionadores de ar tipo janela e split

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Edson Palhares de; Cardoso, Rafael Balbino; Nogueira, Luiz Augusto Horta [Universidade Federal de Itajuba (EXCEN/UNIFEI), MG (Brazil). Centro de Excelencia em Eficiencia Energetica

    2010-07-01

    The air-conditioners of window end Split type are responsible for a significant portion of energy consumption in residential sector of Brazil, from 20% of the sector. This study evaluates the impact energy of the Seal Program PROCEL in air-conditioners of window end Split type, showing the efficiency gains for the country in terms of energy saving. For this evaluation it was considered the effects of temperature and loss of performance due to age, PROCEL Stamp Program resulted in a power savings of 664 GWh in air-conditioners of window type residential sector in 2008. (author)

  11. A Case Study of Wind-PV-Thermal-Bundled AC/DC Power Transmission from a Weak AC Network

    Science.gov (United States)

    Xiao, H. W.; Du, W. J.; Wang, H. F.; Song, Y. T.; Wang, Q.; Ding, J.; Chen, D. Z.; Wei, W.

    2017-05-01

    Wind power generation and photovoltaic (PV) power generation bundled with the support by conventional thermal generation enables the generation controllable and more suitable for being sent over to remote load centre which are beneficial for the stability of weak sending end systems. Meanwhile, HVDC for long-distance power transmission is of many significant technique advantages. Hence the effects of wind-PV-thermal-bundled power transmission by AC/DC on power system have become an actively pursued research subject recently. Firstly, this paper introduces the technical merits and difficulties of wind-photovoltaic-thermal bundled power transmission by AC/DC systems in terms of meeting the requirement of large-scale renewable power transmission. Secondly, a system model which contains a weak wind-PV-thermal-bundled sending end system and a receiving end system in together with a parallel AC/DC interconnection transmission system is established. Finally, the significant impacts of several factors which includes the power transmission ratio between the DC and AC line, the distance between the sending end system and receiving end system, the penetration rate of wind power and the sending end system structure on system stability are studied.

  12. Universality of ac conduction in disordered solids

    DEFF Research Database (Denmark)

    Dyre, Jeppe; Schrøder, Thomas

    2000-01-01

    The striking similarity of ac conduction in quite different disordered solids is discussed in terms of experimental results, modeling, and computer simulations. After giving an overview of experiment, a macroscopic and a microscopic model are reviewed. For both models the normalized ac conductivity...... as a function of a suitably scaled frequency becomes independent of details of the disorder in the extreme disorder limit, i.e., when the local randomly varying mobilities cover many orders of magnitude. The two universal ac conductivities are similar, but not identical; both are examples of unusual non......-power-law universalities. It is argued that ac universality reflects an underlying percolation determining dc as well as ac conductivity in the extreme disorder limit. Three analytical approximations to the universal ac conductivities are presented and compared to computer simulations. Finally, model predictions...

  13. The AC photovoltaic module is here!

    Science.gov (United States)

    Strong, Steven J.; Wohlgemuth, John H.; Wills, Robert H.

    1997-02-01

    This paper describes the design, development, and performance results of a large-area photovoltaic module whose electrical output is ac power suitable for direct connection to the utility grid. The large-area ac PV module features a dedicated, integrally mounted, high-efficiency dc-to-ac power inverter with a nominal output of 250 watts (STC) at 120 Vac, 60 H, that is fully compatible with utility power. The module's output is connected directly to the building's conventional ac distribution system without need for any dc wiring, string combiners, dc ground-fault protection or additional power-conditioning equipment. With its advantages, the ac photovoltaic module promises to become a universal building block for use in all utility-interactive PV systems. This paper discusses AC Module design aspects and utility interface issues (including islanding).

  14. A Secondary Voltage Control Method for an AC/DC Coupled Transmission System Based on Model Predictive Control

    DEFF Research Database (Denmark)

    Xu, Fengda; Guo, Qinglai; Sun, Hongbin

    2015-01-01

    For an AC/DC coupled transmission system, the change of transmission power on the DC lines will significantly influence the AC systems’ voltage. This paper describes a method to coordinated control the reactive power of power plants and shunt capacitors at DC converter stations nearby, in order t...

  15. Electric efficiency in lighting system and air conditioners replacement and automation of air conditioners split type in public buildings; Eficiencia eletrica na substituicao do sistema de iluminacao e de condicionadores de ar e automacao do sistema de condicionadores de ar tipo split em predios publicos

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcellos, Arnulfo Barroso de; Apolonio, Roberto; Silva, Luciana Oliveira da; Gomes, Fernanda Leles [Universidade Federal de Mato Grosso (UFMT), MT (Brazil); Malheiro, Teresa Irene Ribeiro de Carvalho [Instituto Federal de Educacao, Ciencia e Tecnologia de Mato Grosso (IFMT), MT (Brazil); Barros, Regiane Silva de [Universidade Estadual de Campinas (UNICAMP), SP (Brazil)

    2010-07-01

    The reduction in expenditure on electricity is a major benefit not only consumers but also to utilities. In this context, this article examines the process of replacing the system of internal lighting, window type air conditioners and automation of Split type air conditioners from buildings of public institutions of the state of Mato Grosso during 2009 year and verifies the reduction in annual consumption of electric power and demand active power. Thus, measurements and calculations performed are presented for the interior lighting systems and air conditioners of these buildings before and after implementation of the process of replacing the system of internal lighting and window type air conditioners and automation of Split type air conditioners. This work is the result of integration among the Dealer Network Energy Rede Cemat, the Federal University of Mato Grosso (UFMT) and the Administration of all public buildings, where the academy answered these real issues, solving the specific problem presented. (author)

  16. Study on ac losses of HTS coil carrying ac transport current

    International Nuclear Information System (INIS)

    Dai Taozhen; Tang Yuejin; Li Jingdong; Zhou Yusheng; Cheng Shijie; Pan Yuan

    2005-01-01

    Ac loss has an important influence on the thermal performances of HTS coil. It is necessary to quantify ac loss to ascertain its impact on coil stability and for sizing the coil refrigeration system. In this paper, we analyzed in detail the ac loss components, hysteresis loss, eddy loss and flux flow loss in the pancake HTS coil carrying ac transport current by finite element method. We also investigated the distribution of the ac losses in the coil to study the effects of magnetic field distribution on ac losses

  17. Topologically protected loop flows in high voltage AC power grids

    International Nuclear Information System (INIS)

    Coletta, T; Delabays, R; Jacquod, Ph; Adagideli, I

    2016-01-01

    Geographical features such as mountain ranges or big lakes and inland seas often result in large closed loops in high voltage AC power grids. Sizable circulating power flows have been recorded around such loops, which take up transmission line capacity and dissipate but do not deliver electric power. Power flows in high voltage AC transmission grids are dominantly governed by voltage angle differences between connected buses, much in the same way as Josephson currents depend on phase differences between tunnel-coupled superconductors. From this previously overlooked similarity we argue here that circulating power flows in AC power grids are analogous to supercurrents flowing in superconducting rings and in rings of Josephson junctions. We investigate how circulating power flows can be created and how they behave in the presence of ohmic dissipation. We show how changing operating conditions may generate them, how significantly more power is ohmically dissipated in their presence and how they are topologically protected, even in the presence of dissipation, so that they persist when operating conditions are returned to their original values. We identify three mechanisms for creating circulating power flows, (i) by loss of stability of the equilibrium state carrying no circulating loop flow, (ii) by tripping of a line traversing a large loop in the network and (iii) by reclosing a loop that tripped or was open earlier. Because voltages are uniquely defined, circulating power flows can take on only discrete values, much in the same way as circulation around vortices is quantized in superfluids. (paper)

  18. Development of a solar-powered residential air conditioner: Economic analysis

    Science.gov (United States)

    1975-01-01

    The results of investigations aimed at the development of cost models to be used in the economic assessment of Rankine-powered air conditioning systems for residential application are summarized. The rationale used in the development of the cost model was to: (1) collect cost data on complete systems and on the major equipment used in these systems; (2) reduce these data and establish relationships between cost and other engineering parameters such as weight, size, power level, etc; and (3) derive simple correlations from which cost-to-the-user can be calculated from performance requirements. The equipment considered in the survey included heat exchangers, fans, motors, and turbocompressors. This kind of hardware represents more than 2/3 of the total cost of conventional air conditioners.

  19. Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2013-10-01

    This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

  20. Method and apparatus for analog signal conditioner for high speed, digital x-ray spectrometer

    International Nuclear Information System (INIS)

    Warburton, W.K.; Hubbard, B.

    1999-01-01

    A signal processing system which accepts input from an x-ray detector-preamplifier and produces a signal of reduced dynamic range for subsequent analog-to-digital conversion is disclosed. The system conditions the input signal to reduce the number of bits required in the analog-to-digital converter by removing that part of the input signal which varies only slowly in time and retaining the amplitude of the pulses which carry information about the x-rays absorbed by the detector. The parameters controlling the signal conditioner's operation can be readily supplied in digital form, allowing it to be integrated into a feedback loop as part of a larger digital x-ray spectroscopy system. 13 figs

  1. Size optimization of stand-alone photovoltaic (PV) room air conditioners

    International Nuclear Information System (INIS)

    Chen, Chien-Wei; Zahedi, A.

    2006-01-01

    Sizing of a stand-alone PV system determines the main cost of the system. PV electricity cost is determined by the amount of solar energy received, hence the actual climate and weather conditions such as solar irradiance and ambient temperature affect the size required and cost of the system. Air conditioning demand also depends on the weather conditions. Therefore, sizing a PV powered air conditioner must consider the characteristics of local climate and temperature. In this paper, sizing procedures and special considerations for air conditioning under Melbourne's climatic conditions is presented. The reliability of various PV-battery size combinations is simulated by MATLAB. As a result, excellent system performance can be predicated.(Author)

  2. Modeling of a split type air conditioner with integrated water heater

    International Nuclear Information System (INIS)

    Techarungpaisan, P.; Theerakulpisut, S.; Priprem, S.

    2007-01-01

    This paper presents a steady state simulation model to predict the performance of a small split type air conditioner with integrated water heater. The mathematical model consists of submodels of system components such as evaporator, condenser, compressor, capillary tube, receiver and water heater. These submodels were built based on fundamental principles of heat transfer, thermodynamics, fluid mechanics, empirical relationships and manufacturer's data as necessary. The model was coded into a simulation program and used to predict system parameters of interest such as hot water temperature, condenser exit air temperature, evaporator exit air temperature, mass flow rate of refrigerant, heat rejection in the condenser and cooling capacity of the system. The simulation results were compared with experimental data obtained from an experimental rig built for validating the mathematical model. It was found that the experimental and simulation results are in good agreement

  3. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner Equipment that are effective as of September 15, 2015. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=airsrc_heat.pr_crit_as_heat_pumps Listed products have been submitted to EPA by ENERGY STAR partners that do not participate in the AHRI certification program. EPA will continue to update this list with products that are certified by EPA-recognized certification bodies other than AHRI. The majority of ENERGY STAR products, certified by AHRI, can be found on the CEE/AHRI Verified Directory at http://www.ceedirectory.org/

  4. Modeling of unified power quality conditioner (UPQC) in distribution systems load flow

    International Nuclear Information System (INIS)

    Hosseini, M.; Shayanfar, H.A.; Fotuhi-Firuzabad, M.

    2009-01-01

    This paper presents modeling of unified power quality conditioner (UPQC) in load flow calculations for steady-state voltage compensation. An accurate model for this device is derived to use in load flow calculations. The rating of this device as well as direction of reactive power injection required to compensate voltage to the desired value (1 p.u.) is derived and discussed analytically and mathematically using phasor diagram method. Since performance of the compensator varies when it reaches to its maximum capacity, modeling of UPQC in its maximum rating of reactive power injection is derived. The validity of the proposed model is examined using two standard distribution systems consisting of 33 and 69 nodes, respectively. The best location of UPQC for under voltage problem mitigation in the distribution network is determined. The results show the validity of the proposed model for UPQC in large distribution systems.

  5. Design and Analysis of Grid Connected Photovoltaic Fed Unified Power Quality Conditioner

    Science.gov (United States)

    Dash, Santanu Kumar; Ray, Pravat Kumar

    2016-06-01

    This paper proposes the integration scheme and operation of the Unified Power Quality conditioner (UPQC) with Photovoltaic source as distributed generations for power quality improvement. Thus, it provides a novel PV-grid integration configuration and prevents any adverse situation related to current or voltage in power system. Voltage related issues are maintained by the series part of UPQC and the current related issues are handles by shunt part of the UPQC. The various operation modes of PV-UPQC schemes are broadly classified according to the direction of power flow, (i) Interconnected mode, (ii) Islanding mode. PV-UPQC has advantage over the conventional UPQC scheme as it has developed the capability to compensate the voltage interruption problems Control algorithms for shunt and series part of the UPQC is implemented. Development of the proposed configuration has been designed in the laboratory with control algorithm implemented in dSPACE and results are discussed.

  6. Modeling of unified power quality conditioner (UPQC) in distribution systems load flow

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, M.; Shayanfar, H.A. [Center of Excellence for Power System Automation and Operation, Department of Electrical Engineering, Iran University of Science and Technology, Tehran (Iran); Fotuhi-Firuzabad, M. [Department of Electrical Engineering, Sharif University of Technology, Tehran (Iran)

    2009-06-15

    This paper presents modeling of unified power quality conditioner (UPQC) in load flow calculations for steady-state voltage compensation. An accurate model for this device is derived to use in load flow calculations. The rating of this device as well as direction of reactive power injection required to compensate voltage to the desired value (1 p.u.) is derived and discussed analytically and mathematically using phasor diagram method. Since performance of the compensator varies when it reaches to its maximum capacity, modeling of UPQC in its maximum rating of reactive power injection is derived. The validity of the proposed model is examined using two standard distribution systems consisting of 33 and 69 nodes, respectively. The best location of UPQC for under voltage problem mitigation in the distribution network is determined. The results show the validity of the proposed model for UPQC in large distribution systems. (author)

  7. New Application’s Approach to Unified Power Quality Conditioners for Mitigation of Surge Voltages

    Directory of Open Access Journals (Sweden)

    Yeison Alberto Garcés Gomez

    2016-01-01

    Full Text Available This paper outlines a new approach for the compensation of power systems presented through the use of a unified power quality conditioner (UPQC which compensates impulsive and oscillatory electromagnetic transients. The newly proposed control technique involves a dual analysis of the UPQC where the parallel compensator is modelled as a sinusoidal controlled voltage source, while the series compensator is modelled as a sinusoidal controlled current source, opposed to the traditional approach where the parallel and series compensators are modelled as current and voltage nonsinusoidal sources, respectively. Also a new compensation algorithm is proposed through the application of the theory of generalized reactive power; this is then compared with the theory of active and reactive instantaneous power, or pq theory. The results are presented by means of simulations in MATLAB-Simulink®.

  8. Life-cycle cost and payback period analysis for commercial unitary air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

    2004-03-31

    This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results show how the savings vary among customers facing different electricity prices and other conditions. At 11.5 EER, at least 80% of the users achieve a positive LCC savings. At 12.0 EER, the maximum efficiency analyzed, mean LCC savings are lower but still positive. For the {ge} $65,000 Btu/h to <135,000 Btu/h equipment class, 59% of users achieve a positive LCC savings. For the $135,000 Btu/h to <240,000 Btu/h equipment class, 91% of users achieve a positive LCC savings.

  9. Optimum placement of condensing units of split-type air-conditioners by numerical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Avara, Abdollah; Daneshgar, Ehsan [Mechanical Engineering Department, Persian Gulf University, Bushehr (Iran, Islamic Republic of)

    2008-07-01

    Split-type air-conditioners used in residential or office buildings often have the outdoor condensing units installed at the sidewalls or on the roofs. Installation distance from the supporting wall for the first group and the height of installation for the second group are two factors that affect the condenser efficiency. In this study, a CFD code is used to calculate the effect of distance from the supporting wall on the entrance air temperature and on the on-coil temperature of condenser installed between two walls. In the case of condenser installed on the roof, the effect of installation height of the condenser from the finished roof on on-coil temperature is investigated and the minimum recommended height of installation is determined. (author)

  10. Characterization of cesium uptake mediated by a potassium transport system of bacteria in a soil conditioner

    International Nuclear Information System (INIS)

    Zhang, Pengyao; Idota, Yoko; Yano, Kentaro; Negishi, Masayuki; Kawabata, Hideaki; Arakawa, Hiroshi; Ogihara, Takuo; Morimoto, Kaori; Tsuji, Akira

    2014-01-01

    We found that bacteria in a commercial soil conditioner sold in Ishinomaki, Miyagi, exhibited concentrative and saturable cesium ion (Cs + ) uptake in the natural range of pH and temperature. The concentration of intracellular Cs + could be condensed at least a few times higher compared with the outside medium of the cells. This uptake appeared to be mediated by a K + transport system, since Cs + uptake was dose-dependently inhibited by potassium ion (K + ). Eadie-Hofstee plot analysis indicated that the Cs + uptake involved a single saturable process. The maximum uptake amount (J max ) was the same in the presence and absence of K + , suggesting that Cs + and K + uptakes were competitive with respect to each other. These bacteria might be useful for bioremediation of cesium-contaminated soil. (author)

  11. Comparison of air conditioners for horticulture; Vergelijking van luchtbehandelingssystemen voor de tuinbouw

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, B.; Hendriksen, L. [TNO, Delft (Netherlands)

    2011-12-15

    The desire to reduce energy consumption in the greenhouse sector results into new techniques and applications. As such air conditioners are applied in greenhouses. They serve to control temperature, relative humidity and air flow in the greenhouse. However, because of the totally different climatic conditions in the greenhouses such systems must be adapted. TNO investigates how the systems can be evaluated properly [Dutch] De wens om het energieverbruik in de glastuinbouw omlaag te brengen, leidt tot nieuwe technieken en toepassingen. Zo vinden in de utiliteit gangbare luchtbehandelingssystemen nu ook hun weg naar de kas. Ze dienen om temperatuur, relatieve luchtvochtigheid en luchtbeweging in de kas te beheersen. Maar vanwege de totaal andere klimaatomstandigheden moeten de systemen worden aangepast. TNO onderzoekt hoe de systemen goed kunnen worden geevalueerd.

  12. RNA interference suppression of mucin 5AC (MUC5AC reduces the adhesive and invasive capacity of human pancreatic cancer cells

    Directory of Open Access Journals (Sweden)

    Yamada Nobuya

    2010-05-01

    Full Text Available Abstract Background MUC5AC is a secretory mucin normally expressed in the surface muconous cells of stomach and bronchial tract. It has been known that MUC5AC de novo expression occurred in the invasive ductal carcinoma and pancreatic intraepithelial neoplasm with no detectable expression in normal pancreas, however, its function remains uncertain. Here, we report the impact of MUC5AC on the adhesive and invasive ability of pancreatic cancer cells. Methods We used two MUC5AC expressing cell lines derived from human pancreatic cancer, SW1990 and BxPC3. Small-interfering (si RNA directed against MUC5AC were used to assess the effects of MUC5AC on invasion and adhesion of pancreas cancer cells in vitro and in vivo. We compared parental cells (SW1990 and BxPC3 with MUC5AC suppressed cells by si RNA (si-SW1990 and si-BxPC3. Results MUC5AC was found to express in more than 80% of pancreatic ductal carcinoma specimens. Next we observed that both of si-SW1990 and si-BxPC3 showed significantly lower adhesion and invasion to extracellular matrix components compared with parental cell lines. Expression of genes associated with adhesion and invasion including several integerins, matrix metalloproteinase (MMP -3 and vascular endothelial growth factor (VEGF were down-regulated in both MUC5AC suppressed cells. Furthermore, production of VEGF and phosphorylation of VEGFR-1 were significantly reduced by MUC5AC down regulation. Both of si-SW1990 and si-BxPC3 attenuated activation of Erk1/2. In vivo, si-SW1990 did not establish subcutaneous tumor in nude mice. Conclusions Knockdown of MUC5AC reduced the ability of pancreatic cancer cells to adhesion and invasion, suggesting that MUC5AC might contribute to the invasive motility of pancreatic cancer cells by enhancing the expression of integrins, MMP-3, VEGF and activating Erk pathway.

  13. A comparison of four methods to evaluate the effect of a utility residential air-conditioner load control program on peak electricity use

    Energy Technology Data Exchange (ETDEWEB)

    Newsham, Guy R., E-mail: guy.newsham@nrc-cnrc.gc.ca [National Research Council Canada-Institute for Research in Construction, Building M24, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Birt, Benjamin J. [National Research Council Canada-Institute for Research in Construction, Building M24, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Rowlands, Ian H. [University of Waterloo, Ontario (Canada)

    2011-10-15

    We analyzed the peak load reductions due to a residential direct load control program for air-conditioners in southern Ontario in 2008. In this program, participant thermostats were increased by 2 deg. C for four hours on five event days. We used hourly, whole-house data for 195 participant households and 268 non-participant households, and four different methods of analysis ranging from simple spreadsheet-based comparisons of average loads on event days, to complex time-series regression. Average peak load reductions were 0.2-0.9 kWh/h per household, or 10-35%. However, there were large differences between event days and across event hours, and in results for the same event day/hour, with different analysis methods. There was also a wide range of load reductions between individual households, and only a minority of households contributed to any given event. Policy makers should be aware of how the choice of an analysis method may affect decisions regarding which demand-side management programs to support, and how they might be incentivized. We recommend greater use of time-series methods, although it might take time to become comfortable with their complexity. Further investigation of what type of households contribute most to aggregate load reductions would also help policy makers better target programs. - Highlights: > We analyzed peak load reductions due to residential a/c load control. > We used four methods, ranging from simple comparisons to time-series regression. > Average peak load reductions were 0.2-0.9 kW per household, varying by method. > We recommend a move towards time-series regression for future studies. > A minority of participant households contributed to a given load control event.

  14. RHIC spin flipper AC dipole controller

    Energy Technology Data Exchange (ETDEWEB)

    Oddo, P.; Bai, M.; Dawson, C.; Gassner, D.; Harvey, M.; Hayes, T.; Mernick, K.; Minty, M.; Roser, T.; Severino, F.; Smith, K.

    2011-03-28

    The RHIC Spin Flipper's five high-Q AC dipoles which are driven by a swept frequency waveform require precise control of phase and amplitude during the sweep. This control is achieved using FPGA based feedback controllers. Multiple feedback loops are used to and dynamically tune the magnets. The current implementation and results will be presented. Work on a new spin flipper for RHIC (Relativistic Heavy Ion Collider) incorporating multiple dynamically tuned high-Q AC-dipoles has been developed for RHIC spin-physics experiments. A spin flipper is needed to cancel systematic errors by reversing the spin direction of the two colliding beams multiple times during a store. The spin flipper system consists of four DC-dipole magnets (spin rotators) and five AC-dipole magnets. Multiple AC-dipoles are needed to localize the driven coherent betatron oscillation inside the spin flipper. Operationally the AC-dipoles form two swept frequency bumps that minimize the effect of the AC-dipole dipoles outside of the spin flipper. Both AC bumps operate at the same frequency, but are phase shifted from each other. The AC-dipoles therefore require precise control over amplitude and phase making the implementation of the AC-dipole controller the central challenge.

  15. Cosmic Shear With ACS Pure Parallels

    Science.gov (United States)

    Rhodes, Jason

    2002-07-01

    Small distortions in the shapes of background galaxies by foreground mass provide a powerful method of directly measuring the amount and distribution of dark matter. Several groups have recently detected this weak lensing by large-scale structure, also called cosmic shear. The high resolution and sensitivity of HST/ACS provide a unique opportunity to measure cosmic shear accurately on small scales. Using 260 parallel orbits in Sloan textiti {F775W} we will measure for the first time: beginlistosetlength sep0cm setlengthemsep0cm setlengthopsep0cm em the cosmic shear variance on scales Omega_m^0.5, with signal-to-noise {s/n} 20, and the mass density Omega_m with s/n=4. They will be done at small angular scales where non-linear effects dominate the power spectrum, providing a test of the gravitational instability paradigm for structure formation. Measurements on these scales are not possible from the ground, because of the systematic effects induced by PSF smearing from seeing. Having many independent lines of sight reduces the uncertainty due to cosmic variance, making parallel observations ideal.

  16. Long-term indoor air conditioner filtration and cardiovascular health: A randomized crossover intervention study.

    Science.gov (United States)

    Chuang, Hsiao-Chi; Ho, Kin-Fai; Lin, Lian-Yu; Chang, Ta-Yuan; Hong, Gui-Bing; Ma, Chi-Ming; Liu, I-Jung; Chuang, Kai-Jen

    2017-09-01

    The association of short-term air pollution filtration with cardiovascular health has been documented. However, the effect of long-term indoor air conditioner filtration on the association between air pollution and cardiovascular health is still unclear. We recruited 200 homemakers from Taipei and randomly assigned 100 of them to air filtration or control intervention; six home visits were conducted per year from 2013 to 2014. The participants under air filtration intervention during 2013 were reassigned to control intervention in 2014. The air pollution measurements consisted of particulate matter less than or equal to 2.5μm in diameter (PM 2.5 ) and total volatile organic compounds (VOCs); blood pressure was monitored for each participant during each visit. The following morning, blood samples were collected after air pollution monitoring. The blood samples were used to analyze biological markers, including high sensitivity-C-reactive protein (hs-CRP), 8-hydroxy-2'-deoxyguanosine (8-OHdG) and fibrinogen. Household information, including cleaning, cooking, and air conditioning, was collected by a questionnaire. Mixed-effects models were used to investigate the associations among air pollution measurements, blood pressure and biological markers. The results showed that increased levels of PM 2.5 and total VOCs were associated with increased hs-CRP, 8-OHdG and blood pressure. The health variables were higher among participants in the control intervention phase than among those in the air filtration intervention phase. We concluded that air pollution exposure was associated with systemic inflammation, oxidative stress and elevated blood pressure. The long-term filtration of air pollution with an air conditioner filter was associated with cardiovascular health of adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Evaluation of the use of sludge containing plutonium as a soil conditioner for food crops

    International Nuclear Information System (INIS)

    Myers, D.S.; Silver, W.J.; Coles, D.G.; Lamson, K.C.; McIntyre, D.R.; Mendoza, B.

    1975-01-01

    An experiment was conducted to assess the potential hazard associated with the use of sludge containing plutonium as a soil conditioner for food crops. Conditions were chosen that would maximize exposure to the 239 Pu in the sludge through resuspension and in plant content and thus approximated the maximum potential hazards due to the inhalation and ingestion pathways. The estimated 50-year radiation doses to the pulmonary region of the lung, bone, and liver based on the results of the inhalation experiment are 6 x 10 -4 rem, 1.2 x 10 -3 rem, and 0.55 x 10 -4 rem, respectively. Similarly, the 50-year radiation doses attributable to ingestion of the sludge-grown vegetables were 2.2 x 10 -5 rem to the bone and 1.5 x 10 -5 rem to the liver. Thus, the inhalation pathway is the more critical of the two. The maximum permissible annual doses to the lungs, bone, and the liver for a member of the general public are 1.5, 3.0, and 1.5 rem, respectively. Thus, the maximum credible 50-year lung, bone, and liver dose commitments associated with the use of the 239 Pu-contaminated sludge as a soil conditioner are approximately 4.0 x 10 -2 percent of the annual maximum permissible dose. Under more realistic exposure circumstances, one might expect less drying of the sludge, less resuspension of dust and flying dirt before and during rototilling, and a much smaller sludge vegetable consumption rate. The conservative assumptions made in this analysis tend to assure that actual radiation doses would be even less than those calculated. (auth)

  18. Offshore windfarm connection with low frequency AC transmission technology

    DEFF Research Database (Denmark)

    Qin, Nan; Xu, Zhao; You, Shi

    2009-01-01

    This paper investigates the feasibility of using the low frequency AC transmission (LFAC) system, e.g. fraction of 50 Hz or 60 Hz, for connecting the large offshore wind farm to the grid by modelling and simulation. The LFAC system improves the transmission capacity and distance compared...... to the conventional AC solution at the nominal frequency, e.g. 50 Hz or 60 Hz. and reduces the investment cost compared to the HVDC solution. It is estimated that the LFAC system is competitive in the transmission distance of about 30-150 km. The simulation model of the wind integration using the LFAC system has been...... developed, which consists of three parts, the fixed-speed wind turbine representing a wind farm, the transmission line and the frequency converter. Although the transmission capability is greatly improved by the LFAC system, simulation shows it gives negative influences on the wind turbine operation due...

  19. Design and AC loss analysis of a superconducting synchronous motor

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Q [Cambridge University Engineering Department, Trumpington Street, Cambridge CB2 1PZ (United Kingdom); Majoros, M [Department of Materials Science and Engineering, Ohio State University (United States); Hong, Z [Cambridge University Engineering Department, Trumpington Street, Cambridge CB2 1PZ (United Kingdom); Campbell, A M [Cambridge University Engineering Department, Trumpington Street, Cambridge CB2 1PZ (United Kingdom); Coombs, T A [Cambridge University Engineering Department, Trumpington Street, Cambridge CB2 1PZ (United Kingdom)

    2006-11-15

    This paper gives a conceptual design of a superconducting synchronous motor consisting of both high-temperature superconducting rotating field winding and armature winding. The AC losses of the armature winding of the motor have been investigated experimentally and numerically, by considering the self-field of the superconducting coils and the rotating magnetic field exposed on the armature winding. The recent developments of YBCO-coated conductors present the possibility of achieving a wholly superconducting machine of significantly smaller size and weight than a conventional machine. Both the rotating field winding and the armature winding are composed of YBCO high-temperature superconducting (HTS) coils. A low AC loss armature winding design has been developed for this superconducting synchronous motor. The performance of the machine was investigated by modelling with the finite-element method. The machine's torque is calculated from first principles by considering the angle between the field and the armature main flux lines.

  20. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    International Nuclear Information System (INIS)

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER

  1. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-10-10

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

  2. Pipeline grounding condition: A control of pipe-to-soil potential for AC interference induced corrosion reduction

    CSIR Research Space (South Africa)

    Adedeji, KB

    2017-02-01

    Full Text Available The interference effect from high voltage overhead lines on nearby metallic pipelines is a major challenge for utility owners due to the induced AC potentials on metallic pipelines. Nevertheless, numerous mitigation techniques have been proposed...

  3. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  4. Bioinformatics and Astrophysics Cluster (BinAc)

    Science.gov (United States)

    Krüger, Jens; Lutz, Volker; Bartusch, Felix; Dilling, Werner; Gorska, Anna; Schäfer, Christoph; Walter, Thomas

    2017-09-01

    BinAC provides central high performance computing capacities for bioinformaticians and astrophysicists from the state of Baden-Württemberg. The bwForCluster BinAC is part of the implementation concept for scientific computing for the universities in Baden-Württemberg. Community specific support is offered through the bwHPC-C5 project.

  5. Influences of Cry1Ac broccoli on larval survival and oviposition of diamondback moth.

    Science.gov (United States)

    Yi, Dengxia; Cui, Shusong; Yang, Limei; Fang, Zhiyuan; Liu, Yumei; Zhuang, Mu; Zhang, Yangyong

    2015-01-01

    Larval survival and oviposition behavior of three genotypes of diamondback moth, Plutella xylostella L. (Lepidoptera: Plutellidae), (homozygous Cry1Ac-susceptibile, Cry1Ac-resistant, and their F1 hybrids), on transgenic Bacillus thuringiensis (Bt) broccoli expressing different levels of Cry1Ac protein were evaluated in laboratory. These Bt broccoli lines were designated as relative low, medium, and high, respectively, according to the Cry1Ac content. Untransformed brocccoli plants were used as control. Larval survival of diamondback moth on non-Bt leaves was not significantly different among the three genotypes. The Cry1Ac-resistant larvae could survive on the low level of Bt broccoli plants, while Cry1Ac-susceptible and F1 larvae could not survive on them. The three genotypes of P. xylostella larvae could not survive on medium and high levels of Bt broccoli. In oviposition choice tests, there was no significant difference in the number of eggs laid by the three P. xylostella genotypes among different Bt broccoli plants. The development of Cry1Ac-susceptible and Cry1Ac-resistant P. xylostella on intact Bt plants was also tested in greenhouse. All susceptible P. xylostella larvae died on all Bt plants, while resistant larvae could survive on broccoli, which expresses low Cry1Ac protein under greenhouse conditions. The results of the greenhouse trials were similar to that of laboratory tests. This study indicated that high dose of Bt toxins in broccoli cultivars or germplasm lines is required for effective resistance management. © The Author 2015. Published by Oxford University Press on behalf of the Entomological Society of America.

  6. Study on residential appliances energy efficiency standards Refrigerators, air-conditioners, incandescent lamps, fluorescent lamps, color TVs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.G.; Cho, S.K.; Choi, S.H.; Jung, B.M.; Han, S.B.; Kim, K.D. [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    The energy efficiency standards and rating act, as amended by the rational energy utilization act, provides energy efficiency standards and ratings for 6 types of consumer products(refrigerators, air-conditioners, fluorescent lamps, incandescent lamps, ballasts and cars) authorizes the Ministry of Trade, Industry and Energy(MOTIE) to prescribe amended or new energy efficiency standards and rating standards. This study was initiated by the KIER in 1992. KIER`s assessment of the standards is designed to evaluate their statistical and engineering analysis according to Korean(Industrial) Standards(KS). And to make distinction between the poor efficiency and good efficiency models, 5 grades are classified depending on their tested energy efficiency. This year, based on our analysis, MOTIE mandated updated standards for refrigerators, air-conditioners, incandescent lamps, and fluorescent lamps. Also the objective of this study is to set the energy efficiency standards and to grade for color TV sets. (author). 37 refs., 89 figs., 85 tabs.

  7. Study on emergency power control strategy for AC/DC hybrid power system containing VSC-HVDC

    Science.gov (United States)

    Liu, Lin; Hu, Zhenda; Ye, Rong; Lin, Zhangsui; Yang, Xiaodong; Yi, Yang

    2018-04-01

    This paper presents a comprehensive emergency power control strategy for AC/DC hybrid power systems containing VSC-HVDC. Firstly, the paper analyzes the power support of the VSC-HVDC to the AC lines using the Power Transferring Relativity Factor (PTRF). Then the power adjustment of the VSC-HVDC in several different circumstances are calculated. Finally, the online power control strategies of VSC-HVDC are designed, which could rapidly control the power of the VSC-HVDC, keeping the power flow of AC lines below the upper limit. Furthermore, the strategy is proven to be effective by the simulations with EMTDC/PSCAD.

  8. Alternative Refrigerant Evaluation for High-Ambient-Temperature Environments: R-22 and R-410A Alternatives for Rooftop Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goetzler, William [Navigant Consulting Inc., Burlington, MA (United States); Guernsey, Matt [Navigant Consulting Inc., Burlington, MA (United States); Bargach, Youssef [Navigant Consulting Inc., Burlington, MA (United States)

    2016-09-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for Low-Global Warming Potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants relative to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in packaged or Rooftop Unit (RTU) air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerants selection process, the test procedures, and the final results.

  9. Life cycle analysis of retrofitting with high energy efficiency air-conditioner and fluorescent lamp in existing buildings

    International Nuclear Information System (INIS)

    Techato, Kua-anan; Watts, Daniel J.; Chaiprapat, Sumate

    2009-01-01

    Life cycle analysis of mercury in discarded low energy efficiency fluorescent lamps (36 W) and of HCFC in air-conditioners (12,000 Btu) removed from service has been conducted in this study. The objective was to find out the environmental impact (EDIP 1997 category, waste evaluation) of the products that appear in the waste stream as a result of facility upgrades. The scope of the study starts from retrofitting of the lamps and air-conditioners through recycling and disposal. For a 36 W fluorescent lamp, the bulk waste 1.64E-5 kg, hazardous waste 1.11E-4 kg, radioactive waste 1.09E-9 kg, and slag-ash 6.02E-7 kg occurred at the end of life of the retrofitting cycle. For a 12,000 Btu air-conditioner, the bulk waste 0.58 kg, hazardous waste 0.11 kg, radioactive waste 0.0002 kg, and slag-ash 0.01 kg also occurred at the end of life of the retrofitting cycle. These small amounts become important when viewed at the country level. These quantities imply that the policy makers who deal with hazardous waste should be aware of this waste-generating characteristic before issuing any pertinent policy. Consideration of this characteristic and planning for appropriate waste management methods at the beginning stage will reduce any future problem of contamination by the hazardous waste

  10. Experimental study on the performance of a multi-functional domestic air conditioner with integrated water heater

    International Nuclear Information System (INIS)

    Dong, Jiankai; Li, Hui; Yao, Yang; Jiang, Yiqiang; Zhang, Xinran

    2017-01-01

    Highlights: • A novel MDACWH was presented and experimentally studied. • MDACWH has high performance on making domestic hot water and air conditioning. • The time for heating water reduced to 22.0 min after modification. • Average COP reached 4.32, which was 1.58 times higher than the unmodified unit. - Abstract: The recovery of condenser heat is concerned one of the most effective methods to curb energy consumption in residential dwellings. Aiming at recovering the condenser heat of domestic air conditioner, this paper experimentally studied a multi-functional domestic air conditioner with integrated water heater (MDACWH) which can effectively provide space – cooling and domestic hot water simultaneously. The dynamic operation characteristics, such as hot water supply and energy efficiency were tested to verify the availability of the MDACWH. The results showed that the MDACWH can effectively heat the domestic hot water without losing its cooling capacity. It was also found that with the use of MDACWH, the coefficient of comprehensive energy performance of the MDACWH was about 1.58 times higher than that of the unmodified experimental unit. Furthermore, the water-heating time was shorten remarkably from 128.5 min to 22.0 min. The novel domestic air conditioner, compared with the unmodified initial prototype, can be more practical and provide significant energy savings in space-cooling and hot water supply.

  11. Consumption-efficient regulation and switching concepts for air conditioners in buses; Verbrauchseffiziente Regelungs- und Verschaltungskonzepte fuer Omnibusklimaanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, Christian; Tegethoff, Wilhelm [TLK-Thermo GmbH, Braunschweig (Germany); Koehler, Juergen [TU Braunschweig (Germany). Inst. fuer Thermodynamik; Sonnekalb, Michael [Konvekta AG, Schwalmstadt (Germany)

    2012-07-01

    The reduction of the fuel consumption and the related reduction of CO{sub 2} emissions is one of the most important requirements in the current development of vehicles. This includes the development of fuel-efficient drive systems and the optimization of the so-called auxiliary users such as the air conditioner. The majority of the buses used today have an air conditioner in order to meet the increased demand of passengers for comfort. Since the operation of the air conditioner results in a significant increase in fuel consumption and thus in enhanced emissions of CO{sub 2}, an essential task of the development engineer is to minimize this additional consumption. In order to identify possible optimization potentials, a bus simulation model was developed which investigates not only exclusively compression refrigeration systems, but also is in communication with their relevant systems: heating circuit with engine cooling circuit, vehicle interior, on-board electrical system and vehicle longitudinal dynamics with the drive train. In the contribution under consideration, potentials of energy conservation should be identified that can be achieved due to the use of improved control and switching concepts. For this purpose, both the conventional R-744 (CO{sub 2}) bus air conditioning systems as well as alternative systems such as an ejector cycle were studied by means of a total vehicle simulation of the bus and compared.

  12. THE EFFECT OF SOIL CONDITIONERS ON CELLULOSE, HEMICELLULOSE, AND THE ADL FIBRE FRACTION CONCENTRATION IN DACTYLIS GLOMERATA AND LOLIUM PERENNE

    Directory of Open Access Journals (Sweden)

    Milena Truba

    2017-01-01

    Full Text Available Replicated three times, the research was conducted in the experimental field between 2011 and 2014. Three soil conditioners with the following trade names: UGmax, Eko-Użyźniacz, and Humus Active Papka were used in the experiment, separately or together with NPK fertilisers. They were all used on plots sown with two species of grass, Dactylis glomerata of the Bora variety and Lolium perenne of the Info variety. The plant material from both grass species was tested for the concentration of ADL fraction (% DM, cellulose (% DM, and hemicellulose (% DM. It was found that the concentration of cellulose, hemicelluloses, and the ADL fraction was significantly higher in the biomass of Dactylis glomerata than in the biomass of Lolium perenne. The grass from the plot with the UGmax soil conditioner applied had the highest amount of cellulose and hemicellulose. The lowest amount of those organic compounds was found in the grass treated with UGmax together with mineral fertilisers and in plants treated with Humus Active, together with mineral fertilisers. However, the fertilisers and conditioners did not increase the ADL content in both grass species.

  13. Hardware-in-the-Loop Simulation of a Distribution System with Air Conditioners under Model Predictive Control: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, Bethany F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ruth, Mark F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Krishnamurthy, Dheepak [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Pratt, Annabelle [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lunacek, Monte S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jones, Wesley B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wu, Hongyu [Kansas State University; Mittal, Saurabh [Mitre Corporation; Marks, Jesse [University of Missouri

    2017-08-01

    Many have proposed that responsive load provided by distributed energy resources (DERs) and demand response (DR) are an option to provide flexibility to the grid and especially to distribution feeders. However, because responsive load involves a complex interplay between tariffs and DER and DR technologies, it is challenging to test and evaluate options without negatively impacting customers. This paper describes a hardware-in-the-loop (HIL) simulation system that has been developed to reduce the cost of evaluating the impact of advanced controllers (e.g., model predictive controllers) and technologies (e.g., responsive appliances). The HIL simulation system combines large-scale software simulation with a small set of representative building equipment hardware. It is used to perform HIL simulation of a distribution feeder and the loads on it under various tariff structures. In the reported HIL simulation, loads include many simulated air conditioners and one physical air conditioner. Independent model predictive controllers manage operations of all air conditioners under a time-of-use tariff. Results from this HIL simulation and a discussion of future development work of the system are presented.

  14. Chemical Stability Analysis of Hair Cleansing Conditioners under High-Heat Conditions Experienced during Hair Styling Processes

    Directory of Open Access Journals (Sweden)

    Derek A. Drechsel

    2018-03-01

    Full Text Available Chemical stability is a key component of ensuring that a cosmetic product is safe for consumer use. The objective of this study was to evaluate the chemical stability of commercially available hair cleansing conditioners subjected to high heat stresses from the styling processes of blow drying or straightening. Two hair cleansing conditioners were subjected to temperatures of 60 °C and 185 °C to simulate the use of a blow dryer or flatiron hair straightener, respectively and analyzed via Gas Chromatography-Mass Spectrometry (GC-MS, High-Performance Liquid Chromatography-UV (HPLC and Fourier-Transform Infrared Spectroscopy (FT-IR to capture a chemical profile of the samples. The resulting spectra from matched heated and unheated samples were compared to identify any changes in chemical composition. Overall, no differences in the spectra were observed between the heated and unheated samples at both temperatures evaluated. Specifically, no new peaks were observed during analysis, indicating that no degradation products were formed. In addition, all chemicals identified during GC-MS analysis were known listed ingredients of the products. In summary, no measurable changes in chemical composition were observed in the hair cleansing conditioner samples under high-heat stress conditions. The presented analytical methods can serve as an initial screening tool to evaluate the chemical stability of a cosmetic product under conditions of anticipated use.

  15. Effect of conditioners upon the thermodynamics and kinetics of methane hydrate formation. A preliminary structure-properties relationship study

    Energy Technology Data Exchange (ETDEWEB)

    Di Profio, Pietro; Arca, Simone; Germani, Raimondo; Savelli, Gianfranco

    2005-07-01

    The synthesis and stability of gas hydrates was found to be heavily affected by the presence of small quantities of additives, or conditioners, particularly surfactants. In a recent work, we showed that the enhancement of hydrate formation, both from previously described and newly synthesized surfactants, is probably due to surfactant monomers, rather than micelles, and that the features of hydrate induction time should not be used as a measure of critical micelle concentration. In the present paper, we discuss the results of a structure-properties relationship study in which a preliminary attempt to relate the structural features of several amphiphilic additives to some kinetic and thermodynamic parameters of methane hydrate formation - e.g., induction times, rate of formation, occupancy, etc. - is conducted. According to the present study, it is found that, for a particular conditioner, a reduction of induction time does not correlate to an increase of the formation rate and occupancy, and vice versa. This may be related to the nature of chemical moieties forming a particular amphiphile (e.g., the hydrophobic tail, head group, counterion, etc.). The understanding of the mechanisms by which those moieties play their differential role may be the key tool to the design and synthesis of tailored conditioners. (Author)

  16. Adhesive bonding of super-elastic titanium-nickel alloy castings with a phosphate metal conditioner and an acrylic adhesive.

    Science.gov (United States)

    Matsumura, H; Tanoue, N; Yanagida, H; Atsuta, M; Koike, M; Yoneyama, T

    2003-06-01

    The purpose of the current study was to evaluate the bonding characteristics of super-elastic titanium-nickel (Ti-Ni) alloy castings. Disk specimens were cast from a Ti-Ni alloy (Ti-50.85Ni mol%) using an arc centrifugal casting machine. High-purity titanium and nickel specimens were also prepared as experimental references. The specimens were air-abraded with alumina, and bonded with an adhesive resin (Super-Bond C & B). A metal conditioner containing a phosphate monomer (Cesead II Opaque Primer) was also used for priming the specimens. Post-thermocycling average bond strengths (MPa) of the primed groups were 41.5 for Ti-Ni, 30.4 for Ti and 19.5 for Ni, whereas those of the unprimed groups were 21.6 for Ti, 19.3 for Ti-Ni and 9.3 for Ni. Application of the phosphate conditioner elevated the bond strengths of all alloy/metals (P elastic Ti-Ni alloy castings can be achieved with a combination of a phosphate metal conditioner and a tri-n-butylborane-initiated adhesive resin.

  17. Life cycle analysis of retrofitting with high energy efficiency air-conditioner and fluorescent lamp in existing buildings

    Energy Technology Data Exchange (ETDEWEB)

    Techato, Kua-anan [International Postgraduate Programs in Environmental Management (Hazardous Waste Management) and ERI (Energy Research Institute), Chulalongkorn University, Bangkok 10330 (Thailand); Watts, Daniel J. [Otto H. York Center for Environmental Engineering and Science, New Jersey Institute of Technology, Newark, NJ 07102 (United States); Chaiprapat, Sumate [Department of Civil Engineering, Faculty of Engineering, Prince of Songkla University, Hat Yai Campus, Hat Yai, Songkhla 90112 (Thailand); National Center of Excellence for Environmental and Hazardous Waste Management-Satellite Center at Prince of Songkla University (Thailand)

    2009-01-15

    Life cycle analysis of mercury in discarded low energy efficiency fluorescent lamps (36 W) and of HCFC in air-conditioners (12,000 Btu) removed from service has been conducted in this study. The objective was to find out the environmental impact (EDIP 1997 category, waste evaluation) of the products that appear in the waste stream as a result of facility upgrades. The scope of the study starts from retrofitting of the lamps and air-conditioners through recycling and disposal. For a 36 W fluorescent lamp, the bulk waste 1.64E-5 kg, hazardous waste 1.11E-4 kg, radioactive waste 1.09E-9 kg, and slag-ash 6.02E-7 kg occurred at the end of life of the retrofitting cycle. For a 12,000 Btu air-conditioner, the bulk waste 0.58 kg, hazardous waste 0.11 kg, radioactive waste 0.0002 kg, and slag-ash 0.01 kg also occurred at the end of life of the retrofitting cycle. These small amounts become important when viewed at the country level. These quantities imply that the policy makers who deal with hazardous waste should be aware of this waste-generating characteristic before issuing any pertinent policy. Consideration of this characteristic and planning for appropriate waste management methods at the beginning stage will reduce any future problem of contamination by the hazardous waste. (author)

  18. 78 FR 49318 - Availability of Draft Advisory Circular (AC) 90-106A and AC 20-167A

    Science.gov (United States)

    2013-08-13

    ...] Availability of Draft Advisory Circular (AC) 90-106A and AC 20- 167A AGENCY: Federal Aviation Administration... of draft Advisory Circular (AC) 90-106A, Enhanced Flight Vision Systems and draft AC 20- 167A... Federal holidays. FOR FURTHER INFORMATION CONTACT: For technical questions concerning draft AC 90-106A...

  19. Performance analysis of a novel heat pump type air conditioner coupled with a liquid dehumidification/humidification cycle

    International Nuclear Information System (INIS)

    Cai, Dehua; Qiu, Chengbo; Zhang, Jiazheng; Liu, Yue; Liang, Xiao; He, Guogeng

    2017-01-01

    Graphical abstract: Cycle performance of a small scale heat pump type air conditioner coupled with a liquid desiccant/humidification cycle has been theoretically and experimentally evaluated by the present study. The liquid desiccant and humidification cycle is driven by the exhaust heat of the compressor. LDAC not only greatly improves the indoor air quality by controlling the humidity and temperature independently, but also decrease the electrical energy consumption of the traditional air conditioner. Parametric analysis on cycle performance of the present cycle based on both theoretical and experimental methods are carried out. - Highlights: • Hybrid cycle consists of refrigeration cycle and liquid desiccant cycle is proposed. • Liquid desiccant cycle is driven by the compressor exhaust heat. • Theoretical and experimental studies on cycle performance are provided. • Energy consumption decreases about 22.64% compared with the conventional one. - Abstract: In recent years, liquid desiccant air-conditioning system (LDAC) has shown a great potential alternative to the conventional vapor compression systems. LDAC not only greatly improves the indoor air quality by controlling the humidity and temperature independently, but also deceases the electrical energy consumption of the conventional air conditioner. In this work, the liquid desiccant and humidification cycle is driven by the exhaust heat of the compressor. Cycle performance of a small-scale heat pump type air conditioner coupled with a liquid desiccant/humidification cycle has been theoretically and experimentally evaluated by the present study. Parametric analysis on cycle performance of the present cycle is carried out through both theoretical and experimental methods, and lithium chloride aqueous solution is used as the working fluid of the solution cycle. The thermodynamic analysis results show that while the evaporating temperature of the present cycle increases to 15 °C, the energy consumption

  20. Transmission line capital costs

    International Nuclear Information System (INIS)

    Hughes, K.R.; Brown, D.R.

    1995-05-01

    The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy's Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs

  1. Analysis and Assessment of Operation Risk for Hybrid AC/DC Power System based on the Monte Carlo Method

    Science.gov (United States)

    Hu, Xiaojing; Li, Qiang; Zhang, Hao; Guo, Ziming; Zhao, Kun; Li, Xinpeng

    2018-06-01

    Based on the Monte Carlo method, an improved risk assessment method for hybrid AC/DC power system with VSC station considering the operation status of generators, converter stations, AC lines and DC lines is proposed. According to the sequential AC/DC power flow algorithm, node voltage and line active power are solved, and then the operation risk indices of node voltage over-limit and line active power over-limit are calculated. Finally, an improved two-area IEEE RTS-96 system is taken as a case to analyze and assessment its operation risk. The results show that the proposed model and method can intuitively and directly reflect the weak nodes and weak lines of the system, which can provide some reference for the dispatching department.

  2. Analysis and Assessment of Operation Risk for Hybrid AC/DC Power System based on the Monte Carlo Method

    Directory of Open Access Journals (Sweden)

    Hu Xiaojing

    2018-01-01

    Full Text Available Based on the Monte Carlo method, an improved risk assessment method for hybrid AC/DC power system with VSC station considering the operation status of generators, converter stations, AC lines and DC lines is proposed. According to the sequential AC/DC power flow algorithm, node voltage and line active power are solved, and then the operation risk indices of node voltage over-limit and line active power over-limit are calculated. Finally, an improved two-area IEEE RTS-96 system is taken as a case to analyze and assessment its operation risk. The results show that the proposed model and method can intuitively and directly reflect the weak nodes and weak lines of the system, which can provide some reference for the dispatching department.

  3. The Ethylene Biosynthesis Gene CitACS4 Regulates Monoecy/Andromonoecy in Watermelon (Citrullus lanatus).

    Science.gov (United States)

    Manzano, Susana; Aguado, Encarnación; Martínez, Cecilia; Megías, Zoraida; García, Alicia; Jamilena, Manuel

    2016-01-01

    Monoecious and andromonoecious cultivars of watermelon are characterised by the production of male and female flower or male and hermaphrodite flowers, respectively. The segregation analysis in the offspring of crosses between monoecious and andromonoecious lines has demonstrated that this trait is controlled by a single gene pair, being the monoecious allele M semi-dominant to the andromonoecious allele A. The two studied F1 hybrids (MA) had a predominantly monoecious phenotype since both produced not only female flowers, but also bisexual flowers with incomplete stamens, and hermaphrodite flowers with pollen. Given that in other cucurbit species andromonoecy is conferred by mutations in the ethylene biosynthesis genes CmACS7, CsACS2 and CpACS27A we have cloned and characterised CitACS4, the watermelon gene showing the highest similarity with the formers. CitACS4 encoded for a type ACS type III enzyme that is predominantly expressed in pistillate flowers of watermelon. In the andromonoecious line we have detected a missense mutation in a very conserved residue of CitACS4 (C364W) that cosegregates with the andromonoecious phenotype in two independent F2 populations, concomitantly with a reduction in ethylene production in the floral buds that will develop as hermaphrodite flowers. The gene does not however co-segregates with other sex expression traits regulated by ethylene in this species, including pistillate flowering transition and the number of pistillate flowers per plant. These data indicate that CitAC4 is likely to be involved in the biosynthesis of the ethylene required for stamen arrest during the development of female flowers. The C364W mutation would reduce the production of ethylene in pistillate floral buds, promoting the conversion of female into hermaphrodite flowers, and therefore of monoecy into andromonoecy.

  4. AC distribution system for TFTR pulsed loads

    International Nuclear Information System (INIS)

    Carroll, R.F.; Ramakrishnan, S.; Lemmon, G.N.; Moo, W.I.

    1977-01-01

    This paper outlines the AC distribution system associated with the Tokamak Fusion Test Reactor and discusses the significant areas related to design, protection, and equipment selection, particularly where there is a departure from normal utility and industrial applications

  5. Nonlinear AC susceptibility, surface and bulk shielding

    Science.gov (United States)

    van der Beek, C. J.; Indenbom, M. V.; D'Anna, G.; Benoit, W.

    1996-02-01

    We calculate the nonlinear AC response of a thin superconducting strip in perpendicular field, shielded by an edge current due to the geometrical barrier. A comparison with the results for infinite samples in parallel field, screened by a surface barrier, and with those for screening by a bulk current in the critical state, shows that the AC response due to a barrier has general features that are independent of geometry, and that are significantly different from those for screening by a bulk current in the critical state. By consequence, the nonlinear (global) AC susceptibility can be used to determine the origin of magnetic irreversibility. A comparison with experiments on a Bi 2Sr 2CaCu 2O 8+δ crystal shows that in this material, the low-frequency AC screening at high temperature is mainly due to the screening by an edge current, and that this is the unique source of the nonlinear magnetic response at temperatures above 40 K.

  6. Logistics Reduction: Advanced Clothing System (ACS)

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the Advanced Exploration System (AES) Logistics Reduction (LR) project's Advanced Clothing System (ACS) is to use advanced commercial off-the-shelf...

  7. Performance analysis of the electric vehicle air conditioner by replacing hydrocarbon refrigerant

    Science.gov (United States)

    Santoso, Budi; Tjahjana, D. D. D. P.

    2017-01-01

    The thermal comfort in passenger cabins needs an automotive air-conditioning system. The electric vehicle air conditioner system is driven by an electric compressor which includes a compressor and an electric motor. Almost air-conditioning system uses CFC-12, CFC-22 and HFC-134a as refrigerant. However, CFC-12 and CFC-22 will damage the ozone layer. The extreme huge global warming potentials (GWP) values of CFC-12, CFC-22, and HFC-134a represent the serious greenhouse effect of Earth. This article shows new experimental measurements and analysis by using a mixture of HC-134 to replace HFC-134a. The result is a refrigerating effect, the coefficient of performance and energy factor increase along with cooling capacity, both for HFC-134a and HC-134. The refrigerating effect of HC-134 is almost twice higher than HFC-134a. The coefficient of performance value of HC-134 is also 36.42% greater than HFC-134a. Then, the energy factor value of HC-134 is 3.78% greater than HFC-134a.

  8. Greenhouse gas emissions for refrigerant choices in room air conditioner units.

    Science.gov (United States)

    Galka, Michael D; Lownsbury, James M; Blowers, Paul

    2012-12-04

    In this work, potential replacement refrigerants for window-mounted room air conditioners (RACs) in the U.S. have been evaluated using a greenhouse gas (GHG) emissions analysis. CO(2)-equivalent emissions for several hydrofluoroethers (HFEs) and other potential replacements were compared to the most widely used refrigerants today. Included in this comparison are pure refrigerants that make up a number of hydrofluorocarbon (HFC) mixtures, pure hydrocarbons, and historically used refrigerants such as propane and ammonia. GHG emissions from direct and indirect sources were considered in this thermodynamic analysis. Propylene, dimethyl ether, ammonia, R-152a, propane, and HFE-152a all performed effectively in a 1 ton window unit and produced slightly lower emissions than the currently used R-22 and R-134a. The results suggest that regulation of HFCs in this application would have some effect on reducing emissions since end-of-life emissions remain at 55% of total refrigerant charge despite EPA regulations that mandate 80% recovery. Even so, offsite emissions due to energy generation dominate over direct GHG emissions and all the refrigerants perform similarly in totals of indirect GHG emissions.

  9. The use of helical heat exchanger for heat recovery domestic water-cooled air-conditioners

    International Nuclear Information System (INIS)

    Yi Xiaowen; Lee, W.L.

    2009-01-01

    An experimental study on the performance of a domestic water-cooled air-conditioner (WAC) using tube-in-tube helical heat exchanger for preheating of domestic hot water was carried out. The main aims are to identify the comprehensive energy performance (space cooling and hot water preheating) of the WAC and the optimum design of the helical heat exchanger taking into account the variation in tap water flow rate. A split-type WAC was set up for experimental study at different indoor and outdoor conditions. The cooling output, the amount of recovered heat, and the power consumption for different hot water flow rates were measured. The experimental results showed that the cooling coefficient of performance (COP) of the WAC improves with the inclusion of the heat recovery option by a minimum of 12.3%. This can be further improved to 20.6% by an increase in tap water flow rate. Same result was observed for the comprehensive COP of the WAC. The maximum achievable comprehensive COP was 4.92 when the tap water flow rate was set at 7.7 L/min. The overall heat transfer coefficient of the helical heat exchanger under various operating conditions were determined by Wilson plot. A mathematical model relating the over all heat transfer coefficient to the outer pipe diameter was established which provides a convenient way of optimising the design of the helical heat exchanger

  10. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building.

    Science.gov (United States)

    Ni, Hong-Gang; Cao, Shan-Ping; Chang, Wen-Jing; Zeng, Hui

    2011-07-01

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM(2.5) (Particulate Matter up to 2.5 μm in size) bounded Σ(15)PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM(10) (Particulate Matter up to 10 μm in size) bounded Σ(15)PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of Σ(15)PBDEs via dust inhalation and ingestion for adults reached ∼ 141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Evaluation of malodor for automobile air conditioner evaporator by using laboratory-scale test cooling bench.

    Science.gov (United States)

    Kim, Kyung Hwan; Kim, Sun Hwa; Jung, Young Rim; Kim, Man Goo

    2008-09-12

    As one of the measures to improve the environment in an automobile, malodor caused by the automobile air-conditioning system evaporator was evaluated and analyzed using laboratory-scale test cooling bench. The odor was simulated with an evaporator test cooling bench equipped with an airflow controller, air temperature and relative humidity controller. To simulate the same odor characteristics that occur from automobiles, one previously used automobile air conditioner evaporator associated with unpleasant odors was selected. The odor was evaluated by trained panels and collected with aluminum polyester bags. Collected samples were analyzed by thermal desorption into a cryotrap and subsequent gas chromatographic separation, followed by simultaneous olfactometry, flame ionization detector and identified by atomic emission detection and mass spectrometry. Compounds such as alcohols, aldehydes, and organic acids were identified as responsible odor-active compounds. Gas chromatography/flame ionization detection/olfactometry combined sensory method with instrumental analysis was very effective as an odor evaluation method in an automobile air-conditioning system evaporator.

  12. Development of a solar-powered residential air conditioner: Screening analysis

    Science.gov (United States)

    1975-01-01

    Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

  13. Capacity enhancement and flexible operation of unified power quality conditioner in smart and microgrid network

    Directory of Open Access Journals (Sweden)

    Shafiuzzaman Khan Khadem

    2018-01-01

    Full Text Available This paper presents a new approach to design Unified Power Quality Conditioner (UPQC, termed as distributed UPQC (D-UPQC, for smart or microgrid network where capacity enhancement and flexible operation of UPQC are the important issues. This paper shows the possibility of capacity enhancement and operational flexibility of UPQC through a coordinated control of existing resources. This UPQC consists of a single unit series active power filter (APFse and multiple shunt APF (APFsh units in a distributed (parallel mode. These units can be connected with a common/separate dc linked capacitor(s. The requirement of capacity enhancement arises from the flexibility to cope up with the increased harmonic load demand at low voltage (LV distribution network. This can be accomplished by a coordinated control where multiple APFsh units are operated by utilizing the capacity of APFse while it is in idle/low mode using. Operational flexibility can be accomplished by compensating (i the reactive and harmonic current individually or (ii splitting the combined reactive and harmonic current/power among the APFsh units. Design and control issues have been discussed to identify the capacity enhancement limit with the possibility of operational flexibility. A system then has been simulated in MATLAB to show the effectiveness of D-UPQC in capacity enhancement and flexible operation by applying its existing resource utilization capability.

  14. Analysis and experimental verification of a control scheme for unified power quality conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Peng Cheng Zhu; Xun Li; Yong Kang; Jian Chen [Huazhong Univ. of Science and Techmnology, Wuhan (China). Dept. of Electrical Engineering

    2005-07-01

    Improving power quality for sensitive load by a Unified Power Quality Conditioner (UPQC) in a distributed generation system is presented in this paper. The power balance of a UPQC, consisting of back-to-back connected series and shunt Active Filters (AF), is analysed. Based on the analysis a novel control scheme is established in a 2-phase Synchronous Rotating d-q Frame (SRF). In this control scheme, the series AF is controlled as a current source and makes the input current sinusoidal, while the shunt AF is controlled as a voltage source and keeps the load voltage in the normal value. With the proposed control strategy, the UPQC is capable of compensating not only harmonic and reactive currents of the load but also grid voltage distortion. There is no harmonic interference between harmonic-producing loads and harmonic-sensitive loads, which are connected on the common bus. The performance of a UPQC with the proposed control scheme under nonlinear load and grid voltage distortion is investigated with simulation as well as experimental works. (Author)

  15. Power quality enhancement at distribution level utilizing the unified power quality conditioner (UPQC)

    Science.gov (United States)

    Khadkikar, Vinod

    The present doctoral work is based on the philosophy of optimal utilization of the available resources in a most effective and efficient way to improve the product efficiency and to reduce the overall cost. This work proposes a novel control philosophy termed as power angle control (PAC), in which both the series and shunt inverters share the load reactive power in co-ordination with each other without affecting the basic UPQC compensation capabilities. This eventually results in a better utilization of the series inverter, reduction in the shunt inverter rating to some extent and ultimately in the reduction of the overall cost of UPQC. Moreover, in this thesis work several other control approaches are also proposed, such as, unit vector template generation, quadrature voltage injection, generalized single-phase p-q theory and novel current unbalance compensation approach. All the developed concepts are successfully validated through digital simulation as well as extensive experimental investigations. Keywords. power quality, active power filter, unified power quality conditioner, reactive power compensation, harmonics compensation.

  16. Effect of shampoo, conditioner and permanent waving on the molecular structure of human hair.

    Science.gov (United States)

    Zhang, Yuchen; Alsop, Richard J; Soomro, Asfia; Yang, Fei-Chi; Rheinstädter, Maikel C

    2015-01-01

    The hair is a filamentous biomaterial consisting of the cuticle, the cortex and the medulla, all held together by the cell membrane complex. The cortex mostly consists of helical keratin proteins that spiral together to form coiled-coil dimers, intermediate filaments, micro-fibrils and macro-fibrils. We used X-ray diffraction to study hair structure on the molecular level, at length scales between ∼3-90 Å, in hopes of developing a diagnostic method for diseases affecting hair structure allowing for fast and noninvasive screening. However, such an approach can only be successful if common hair treatments do not affect molecular hair structure. We found that a single use of shampoo and conditioner has no effect on packing of keratin molecules, structure of the intermediate filaments or internal lipid composition of the membrane complex. Permanent waving treatments are known to break and reform disulfide linkages in the hair. Single application of a perming product was found to deeply penetrate the hair and reduce the number of keratin coiled-coils and change the structure of the intermediate filaments. Signals related to the coiled-coil structure of the α-keratin molecules at 5 and 9.5 Å were found to be decreased while a signal associated with the organization of the intermediate filaments at 47 Å was significantly elevated in permed hair. Both these observations are related to breaking of the bonds between two coiled-coil keratin dimers.

  17. Effect of shampoo, conditioner and permanent waving on the molecular structure of human hair

    Directory of Open Access Journals (Sweden)

    Yuchen Zhang

    2015-10-01

    Full Text Available The hair is a filamentous biomaterial consisting of the cuticle, the cortex and the medulla, all held together by the cell membrane complex. The cortex mostly consists of helical keratin proteins that spiral together to form coiled-coil dimers, intermediate filaments, micro-fibrils and macro-fibrils. We used X-ray diffraction to study hair structure on the molecular level, at length scales between ∼3–90 Å, in hopes of developing a diagnostic method for diseases affecting hair structure allowing for fast and noninvasive screening. However, such an approach can only be successful if common hair treatments do not affect molecular hair structure. We found that a single use of shampoo and conditioner has no effect on packing of keratin molecules, structure of the intermediate filaments or internal lipid composition of the membrane complex. Permanent waving treatments are known to break and reform disulfide linkages in the hair. Single application of a perming product was found to deeply penetrate the hair and reduce the number of keratin coiled-coils and change the structure of the intermediate filaments. Signals related to the coiled-coil structure of the α-keratin molecules at 5 and 9.5 Å were found to be decreased while a signal associated with the organization of the intermediate filaments at 47 Å was significantly elevated in permed hair. Both these observations are related to breaking of the bonds between two coiled-coil keratin dimers.

  18. Meloidogyne javanica control by Pochonia chlamydosporia, Gracilibacillus dipsosauri and soil conditioner in tomato

    Directory of Open Access Journals (Sweden)

    Guilherme Silva de Podestá

    2013-06-01

    Full Text Available Organic matter plays a fundamental role in the antagonistic activity of microorganisms against phytonematode populations on the soil. In this study, the compatibility between the fungus Pochonia chlamydosporia (Pc-12 and the rhizobacterium Gracilibacillus dipsosauri (MIC 14 was evaluated in vitro, as well as the effect of the fungus at the concentration of 5,000 chlamydospores per gram of soil, rhizobacterium at 4.65 x 10(9 cells/g of soil, and the soil conditioner Ribumin® at 10 g/pot, either alone or in combination, against Meloidogyne javanica population in tomato plants (3,000 eggs/pot. A suspension of water or Ribumin® alone was applied on the soil as negative control, while a suspension of nematode eggs was applied as positive control. The reduction in the number of galls in roots per plant was 48 and 41% for the treatments Ribumin + MIC 14 + Pc-12 and MIC 14 + Pc-12, respectively. Regarding to the number of eggs per plant, MIC 14 and Pc-12 + Ribumin led to a reduction by 26 and 21%, respectively, compared to the control treatment. Interaction between the nematophagous fungus and the rhizobacterium was positive for the nematode control, even though G. dipsosauri inhibited P. chlamydosporia growth by up to 30% in in vitro tests.

  19. Marketingová komunikace AC Sparta Praha

    OpenAIRE

    Fanta, Jan

    2016-01-01

    Title: Marketing communications of AC Sparta Praha Objectives: The main objective of this thesis is to analyze contemporary state of marketing communications with the audience of AC Sparta Praha, identify deficiencies and develop a proposal to improve the marketing communications with fans of this club. Methods: In this thesis have been used methods of case study, analysis of available documents and texts, structured interview with director od marketing, and director of communications and pub...

  20. Cooperative Frequency Control for Autonomous AC Microgrids

    DEFF Research Database (Denmark)

    Shafiee, Qobad; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2015-01-01

    Distributed secondary control strategies have been recently studied for frequency regulation in droop-based AC Microgrids. Unlike centralized secondary control, the distributed one might fail to provide frequency synchronization and proportional active power sharing simultaneously, due to having...... not require measuring the system frequency as compared to the other presented methods. An ac Microgrid with four sources is used to verify the performance of the proposed control methodology....

  1. Construction and characterisation of near-isogenic Plutella xylostella (Lepidoptera: Plutellidae) strains resistant to Cry1Ac toxin.

    Science.gov (United States)

    Zhu, Xun; Lei, Yanyuan; Yang, Yanjv; Baxter, Simon W; Li, Jianhong; Wu, Qingjun; Wang, Shaoli; Xie, Wen; Guo, Zhaojiang; Fu, Wei; Zhang, Youjun

    2015-02-01

    Resistance to insecticidal Bacillus thuringiensis (Bt) toxins has arisen in multiple populations of the worldwide Brassica pest Plutella xylostella (L.). To help elucidate the mechanism of resistance to Bt Cry1Ac toxin in a population from Florida, two pairs of near-isogenic lines (NILs) were developed. NILs were generated using either backcross or recombinant inbred line methodologies and evaluated for near-isogenicity with inter-simple-sequence-repeat (ISSR) markers. Backcross line BC6F4 maintained a similar level of Cry1Ac resistance to parental strain DBM1Ac-R (>5000-fold) yet showed 98.24% genetic similarity to the susceptible parental strain DBM1Ac-S. Single-pair backcrosses between DBM1Ac-S and BC6F4 revealed that Cry1Ac resistance was controlled by one recessive autosomal locus. BC6F4 exhibited high levels of cross-resistance to Cry1Ab and Cry1Ah but not to Cry1Ca or Cry1Ie. Near-isogenic strains were constructed to provide a reliable biological system to investigate the mechanism of Cry1Ac resistance in P. xylostella. These data suggest that resistance to Cry1Ac, Cry1Ab and Cry1Ah is probably caused by the alteration of a common receptor not recognised by Cry1Ca or Cry1Ie. Understanding Bt toxin cross-resistance provides valuable information to consider when developing pest control strategies to delay resistance evolution. © 2014 Society of Chemical Industry. © 2014 Society of Chemical Industry.

  2. Transport AC losses in YBCO coated conductors

    Energy Technology Data Exchange (ETDEWEB)

    Majoros, M [Ohio State University, Columbus, OH 43210 (United States); Ye, L [IRC in Superconductivity, University of Cambridge, Madingley Road, Cambridge CB3 0HE (United Kingdom); Velichko, A V [IRC in Superconductivity, University of Cambridge, Madingley Road, Cambridge CB3 0HE (United Kingdom); Coombs, T A [IRC in Superconductivity, University of Cambridge, Madingley Road, Cambridge CB3 0HE (United Kingdom); Sumption, M D [Ohio State University, Columbus, OH 43210 (United States); Collings, E W [Ohio State University, Columbus, OH 43210 (United States)

    2007-09-15

    Transport AC loss measurements have been made on YBCO-coated conductors prepared on two different substrate templates-RABiTS (rolling-assisted biaxially textured substrate) and IBAD (ion-beam-assisted deposition). RABiTS samples show higher losses compared with the theoretical values obtained from the critical state model, with constant critical current density, at currents lower than the critical current. An origin of this extra AC loss was demonstrated experimentally by comparison of the AC loss of two samples with different I-V curves. Despite a difference in I-V curves and in the critical currents, their measured losses, as well as the normalized losses, were practically the same. However, the functional dependence of the losses was affected by the ferromagnetic substrate. An influence of the presence of a ferromagnetic substrate on transport AC losses in YBCO film was calculated numerically by the finite element method. The presence of a ferromagnetic substrate increases transport AC losses in YBCO films depending on its relative magnetic permeability. The two loss contributions-transport AC loss in YBCO films and ferromagnetic loss in the substrate-cannot be considered as mutually independent.

  3. Proportional-Integral-Resonant AC Current Controller

    Directory of Open Access Journals (Sweden)

    STOJIC, D.

    2017-02-01

    Full Text Available In this paper an improved stationary-frame AC current controller based on the proportional-integral-resonant control action (PIR is proposed. Namely, the novel two-parameter PIR controller is applied in the stationary-frame AC current control, accompanied by the corresponding parameter-tuning procedure. In this way, the proportional-resonant (PR controller, common in the stationary-frame AC current control, is extended by the integral (I action in order to enable the AC current DC component tracking, and, also, to enable the DC disturbance compensation, caused by the voltage source inverter (VSI nonidealities and by nonlinear loads. The proposed controller parameter-tuning procedure is based on the three-phase back-EMF-type load, which corresponds to a wide range of AC power converter applications, such as AC motor drives, uninterruptible power supplies, and active filters. While the PIR controllers commonly have three parameters, the novel controller has two. Also, the provided parameter-tuning procedure needs only one parameter to be tuned in relation to the load and power converter model parameters, since the second controller parameter is directly derived from the required controller bandwidth value. The dynamic performance of the proposed controller is verified by means of simulation and experimental runs.

  4. Lamin A/C might be involved in the EMT signalling pathway.

    Science.gov (United States)

    Zuo, Lingkun; Zhao, Huanying; Yang, Ronghui; Wang, Liyong; Ma, Hui; Xu, Xiaoxue; Zhou, Ping; Kong, Lu

    2018-07-15

    We have previously reported a heterogeneous expression pattern of the nuclear membrane protein lamin A/C in low- and high-Gleason score (GS) prostate cancer (PC) tissues, and we have now found that this change is not associated with LMNA mutations. This expression pattern appears to be similar to the process of epithelial to mesenchymal transition (EMT) or to that of mesenchymal to epithelial transition (MET). The role of lamin A/C in EMT or MET in PC remains unclear. Therefore, we first investigated the expression levels of and the associations between lamin A/C and several common EMT markers, such as E-cadherin, N-cadherin, β-catenin, snail, slug and vimentin in PC tissues with different GS values and in different cell lines with varying invasion abilities. Our results suggest that lamin A/C might constitute a type of epithelial marker that better signifies EMT and MET in PC tissue, since a decrease in lamin A/C expression in GS 4 + 5 cases is likely associated with the EMT process, while the re-expression of lamin A/C in GS 5 + 4 cases is likely linked with MET. The detailed GS better exhibited the changes in lamin A/C and the EMT markers examined. Lamin A/C overexpression or knockdown had an impact on EMT biomarkers in a cell model by direct regulation of β-catenin. Hence, we suggest that lamin A/C might serve as a reliable epithelial biomarker for the distinction of PC cell differentiation and might also be a fundamental factor in the occurrence of EMT or MET in PC. Copyright © 2018. Published by Elsevier B.V.

  5. The Effect of the Feedback Controller on Superconducting Tokamak AC Losses + AC-CRPP user manual

    International Nuclear Information System (INIS)

    Schaerz, B.; Bruzzone, P.; Favez, J.Y.; Lister, J.B.; Zapretilina, E.

    2001-11-01

    Superconducting coils in a Tokamak are subject to AC losses when the field transverse to the coil current varies. A simple model to evaluate the AC losses has been derived and benchmarked against a complete model used in the ITER design procedure. The influence of the feedback control strategy on the AC losses is examined using this model. An improved controller is proposed, based on this study. (author)

  6. Response of microbial community of organic-matter-impoverished arable soil to long-term application of soil conditioner derived from dynamic rapid fermentation of food waste.

    Science.gov (United States)

    Hou, Jiaqi; Li, Mingxiao; Mao, Xuhui; Hao, Yan; Ding, Jie; Liu, Dongming; Xi, Beidou; Liu, Hongliang

    2017-01-01

    Rapid fermentation of food waste can be used to prepare soil conditioner. This process consumes less time and is more cost-effective than traditional preparation technology. However, the succession of the soil microbial community structure after long-term application of rapid fermentation-derived soil conditioners remains unclear. Herein, dynamic rapid fermentation (DRF) of food waste was performed to develop a soil conditioner and the successions and diversity of bacterial communities in an organic-matter-impoverished arable soil after six years of application of DRF-derived soil conditioner were investigated. Results showed that the treatment increased soil organic matter (SOM) accumulation and strawberry yield by 5.3 g/kg and 555.91 kg/ha, respectively. Proteobacteria, Actinobacteria, Acidobacteria, and Firmicutes became the dominant phyla, occupying 65.95%-77.52% of the bacterial sequences. Principal component analysis (PCA) results showed that the soil bacterial communities were largely influenced by the treatment. Redundancy analysis (RDA) results showed that the relative abundances of Gemmatimonadetes, Chloroflexi, Verrucomicrobia, Nitrospirae, and Firmicutes were significantly correlated with soil TC, TN, TP, NH4+-N, NO3--N, OM, and moisture. These communities were all distributed in the soil samples collected in the sixth year of application. Long-term treatment did not enhance the diversity of bacterial species but significantly altered the distribution of major functional bacterial communities in the soils. Application of DRF-derived soil conditioner could improve the soil quality and optimize the microbial community, ultimately enhancing fruit yields.

  7. Design and synthesis of 225Ac radioimmunopharmaceuticals

    International Nuclear Information System (INIS)

    McDevitt, Michael R.; Ma, Dangshe; Simon, Jim; Frank, R. Keith; Scheinberg, David A.

    2002-01-01

    The alpha-particle-emitting radionuclides 213 Bi, 211 At, 224 Ra are under investigation for the treatment of leukemias, gliomas, and ankylosing spondylitis, respectively. 213 Bi and 211 At were attached to monoclonal antibodies and used as targeted immunotherapeutic agents while unconjugated 224 Ra chloride selectively seeks bone. 225 Ac possesses favorable physical properties for radioimmunotherapy (10 d half-life and 4 net alpha particles), but has a history of unfavorable radiolabeling chemistry and poor metal-chelate stability. We selected functionalized derivatives of DOTA as the most promising to pursue from out of a group of potential 225 Ac chelate compounds. A two-step synthetic process employing either MeO-DOTA-NCS or 2B-DOTA-NCS as the chelating moiety was developed to attach 225 Ac to monoclonal antibodies. This method was tested using several different IgG systems. The chelation reaction yield in the first step was 93±8% radiochemically pure (n=26). The second step yielded 225 Ac-DOTA-IgG constructs that were 95±5% radiochemically pure (n=27) and the mean percent immunoreactivity ranged from 25% to 81%, depending on the antibody used. This process has yielded several potential novel targeted 225 Ac-labeled immunotherapeutic agents that may now be evaluated in appropriate model systems and ultimately in humans

  8. CHARACTERISTICS OF COMPOSTED BIO-TOILET RESIDUE AND ITS POTENTIAL USE AS A SOIL CONDITIONER

    Directory of Open Access Journals (Sweden)

    Jovita Triastuti

    2016-10-01

    Full Text Available Bio-toilet is a dry toilet where human excreta is trapped in a lignocelluloses soil matrix such as wood sawdust, then it is decomposed by aerobic  bacteria to organic compost rich in minerals such as N, P, and K. The study aimed to characterize the bio-toilet residue and its potential use as a soil conditioner for Jatropha curcas. The study was conducted in a private school of Daarut Tauhid in Bandung West Java. A bio-toilet S-50 type of Japan was constructed consisting of a composting chamber, mixer, heater, exhaust fan, and closet. The composting chamber was filled with 63 kg of Albizzia sawdust. Feces and urine was loaded daily by 54 students for 122-day observation. At the end of observation, the decomposed bio-toilet residue was evaluated for its physical properties such as bulk density (rb, porosity (%, and water retention (WR. Chemical properties such as pH, C/N ratio, N, P, and K, as well as microbiological properties such as numbers of bacteria, fungi, and worm eggs were evaluated at 14 and 122 days of decomposition process. Effect of the composted bio-toilet residue as plant growth media was evaluated using J. curcass as a plant indicator. Before it was used as a growth media, the composted bio-toilet residue was dried in a room temperature for 30 days. The experiment was designed in a completely randomized design 2 x 4 factorial with three replications. The first factor was the rate of composted biotoilet residue, i.e., 0, 20, 40, and 60% based on weight of the growth media mixture (1500 g pot-1, and the second was NPK fertilizer addition at 0 and 2 g pot-1. Each pot was planted with 2-month old of J. curcas seedlings. Parameters evaluated were leaf number, leaf area, stem height, and stem diameter measured at 12 weeks after planting. The results showed that the biotoilet residue was suitable as soil conditioner because it had high porosity (76%, low bulk density (0.19 g cm-3, high water retention (2.6 ml g-1 DM, neutral pH (6.9, C

  9. AC measurements on uranium doped high temperature superconductors

    International Nuclear Information System (INIS)

    Eisterer, M.

    1999-11-01

    The subject of this thesis is the influence of fission tracks on the superconducting properties of melt textured Y-123. The critical current densities, the irreversibility lines and the transition temperature were determined by means of ac measurements. The corresponding ac techniques are explored in detail. Deviations of the ac signal from the expectations according to the Bean model were explained by the dependence of the shielding currents on the electric field. This explanation is supported by the influence of the ac amplitude and frequency on the critical current density but also by a comparison of the obtained data with other experimental techniques. Y-123 has to be doped with uranium in order to induce fission tracks. Uranium forms normal conducting clusters, which are nearly spherical, with a diameter of about 300 nm. Fission of uranium-235 by thermal neutrons creates two high energy ions with a total energy of about 160 MeV. Each of these fission products induces a linear defect with a diameter of about 10 nm. The length of one fission track is 2-4 μm. At 77 K the critical current density is enhanced by the pinning action of the uranium clusters, compared to undoped samples. With decreasing temperature this influence becomes negligible. The critical current densities are strongly enhanced due to the irradiation. At low magnetic fields we find extremely high values for melt textured materials, e.g. 2.5x10 9 Am -2 at 77 K and 0.25 T or 6x10 10 Am -2 at 5 K. Since the critical current was found to be inverse proportional to the square root of the applied magnetic field it decreases rapidly as the field increases. This behavior is predicted by simple theoretical considerations, but is only valid at low temperatures as well as in low magnetic fields at high temperatures. At high fields the critical current drops more rapidly. The irreversibility lines are only slightly changed by this irradiation technique. Only a small shift to higher fields and temperatures

  10. Normal form of particle motion under the influence of an ac dipole

    Directory of Open Access Journals (Sweden)

    R. Tomás

    2002-05-01

    Full Text Available ac dipoles in accelerators are used to excite coherent betatron oscillations at a drive frequency close to the tune. These beam oscillations may last arbitrarily long and, in principle, there is no significant emittance growth if the ac dipole is adiabatically turned on and off. Therefore the ac dipole seems to be an adequate tool for nonlinear diagnostics provided the particle motion is well described in the presence of the ac dipole and nonlinearities. Normal forms and Lie algebra are powerful tools to study the nonlinear content of an accelerator lattice. In this article a way to obtain the normal form of the Hamiltonian of an accelerator with an ac dipole is described. The particle motion to first order in the nonlinearities is derived using Lie algebra techniques. The dependence of the Hamiltonian terms on the longitudinal coordinate is studied showing that they vary differently depending on the ac dipole parameters. The relation is given between the lines of the Fourier spectrum of the turn-by-turn motion and the Hamiltonian terms.

  11. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

  12. Use of expanded vermiculite as a soil conditioner in the tropics

    International Nuclear Information System (INIS)

    Libardi, P.L.; Salati, E.; Reichardt, K.

    1983-01-01

    Expanded vermiculite is used as a soil conditioner to improve soil-water retention and cation exchange properties of poor tropical soils (alfisols and oxisols). Results show that fresh laboratory mixtures of soil and expanded vermiculite increase the amount of water retained, the process being affected by the rate of application, origin and granule size of the vermiculite. Pot experiments show that the incorporation of vermiculite into the soil increases soil-water storage capacity without affecting evapotranspiration rates. This indicates that crops grown in soils conditioned with vermiculite lose the same quantities of water through evapotranspiration, but support plants for longer periods without water addition. Diminishing irrigation frequency raises the possibility of irrigating larger areas and/or using irrigation equipment more rationally. Field experiments have been developed to examine the potential use of vermiculite, at low application rates, in extensive agriculture. Encouraging results have been obtained regarding crop resistance to drought spells, and yield in vermiculite conditioned soils. This new management practice seems to be one solution for semi-arid agriculture and for areas of soil with poor water retention properties subjected to irregular rainfall patterns. Experiments show also that vermiculite addition improves root growth and affects soil nutrient ratios. This depends again on soil type, vermiculite origin and granule size, application rates, form of incorporation into the soil and type of crop. It affects Ca/K, Ca/Mg and Mg/K ratios in soil extracts and the availability of micronutrients. Tracers were used to study some aspects of the dynamics of N and P. (author)

  13. Flow, stock, and impact assessment of refrigerants in the Japanese household air conditioner sector.

    Science.gov (United States)

    Xue, Mianqiang; Kojima, Naoya; Machimura, Takashi; Tokai, Akihiro

    2017-05-15

    Refrigerants provide society with great benefits while have the potential to cause adverse effects on the environment and human health. The present study estimated time-dependent flows and stocks and assessed the effects of refrigerants (R-22, R-410a, and R-32) in household air conditioners in Japan. It was found that stock of R-22 and R-410a peaked at 49,147t in 2000 and 55,994t in 2017, respectively. The largest flow of R-22 and R-410a to waste phase occurred at 3417t/yr. in 2005 and 4011t/yr. in 2023, respectively. The total global warming potential (GWP) due to refrigerant emissions increased from 3.6kt CO 2 eq. in 1952 to 6999kt CO 2 eq. in 2019, and then decreased to 5314kt CO 2 eq. in 2030. The ozone depletion potential (ODP) peaked at 141t CFC-11 eq. in 2002. When substituting R-410a for R-22, the ODP decreased 50% while the GDP increased 8%. When substituting R-32 for R-410a, there was no effect on the ODP while the GDP decreased 6%. The human health damage due to the global warming effect of refrigerant emission was much higher than that due to the ozone depleting effect. The refrigerant emission in use and waste management phases dominated the human health damage. The dynamic estimation not only allows us to evaluate the performance of past policies but also supports the future sustainable management associated with the health effects of refrigerants. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Best control strategy for unified power quality conditioner (UPQC) based on simulation

    Energy Technology Data Exchange (ETDEWEB)

    Shayanfar, H.A. [Iran Univ. of Science and Technology, Tehran (Iran, Islamic Republic of). Dept. of Electrical Engineering; Tabatabaei, N.M. [Azarbaijan Univ. of Tarbiat Moallem, Tabriz (Iran, Islamic Republic of). Dept. of Electrical Engineering; Mokhtarpour, A. [Islamic Azad Univ., Tabriz (Iran, Islamic Republic of). Dept. of Electrical Engineering

    2007-07-01

    Electronic devices used in both industry and residences need high-quality energy to work properly. Unified Power Quality Conditioners (UPQC) solve any power quality problems faced by these devices. Three new control strategies for UPQCs were presented and their operation was investigated and compared using the MATLAB Simulink simulation software package. A UPQC consists of a Shunt-Active Filter and a Series Active Filter with a common direct current link to compensate for any source currents and delivered voltage to the load. As such, it isolates the utility from current quality problems associated with load. It also isolates the load from the voltage quality problems of the utility. In the first control strategy, the Parallel Active Filter (PAF) and Series Active Filter (SAF) are based on the Fourier transform theory. In the second control strategy, the Parallel Active Filter is based on the power quality theory and the Series Active Filter is based on the Fourier transform theory. In the third control strategy, the Parallel Active Filter is based on Fourier transform theory and the Series Active Filter is based on positive sequence detection. Operating the PAF using these methods compensates for reactive power and current harmonics, while operating the SAF compensates for imbalances, voltage harmonics and positive and zero sequences of utility voltages. MATLAB simulation software was used to explain the compensation resolution and speed of the 3 new control strategies. According to simulation test results, it was concluded that the best compensation speed and resolution can be obtained using the third control strategy. 7 refs., 2 tabs., 24 figs.

  15. Locating room air-conditioners at floor level for energy saving in residential buildings

    International Nuclear Information System (INIS)

    Gao, C.F.; Lee, W.L.; Chen Hua

    2009-01-01

    Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential

  16. Locating room air-conditioners at floor level for energy saving in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gao, C.F.; Lee, Hua; Chen, W.L. [Department of Building Services Engineering, Hong Kong Polytechnic University, Hung Hom (China)

    2009-08-15

    Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential

  17. Approaches to building single-stage AC/AC conversion switch-mode audio power amplifiers

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2004-01-01

    This paper discusses the possible topologies and promising approaches towards direct single-phase AC-AC conversion of the mains voltage for audio applications. When compared to standard Class-D switching audio power amplifiers with a separate power supply, it is expected that direct conversion...

  18. The experimental investigation of refrigerant distribution and leaking characteristics of R290 in split type household air conditioner

    International Nuclear Information System (INIS)

    Tang, Weier; He, Guogeng; Cai, Dehua; Zhu, Yihao; Zhang, Aoni; Tian, Qiqi

    2017-01-01

    Highlights: • A new quasi-liquid nitrogen method (QLNM) was proposed and firstly applied in experiments. • The R290 distribution was investigated by QLNM and the results proved the validation. • A solenoid valve was proposed to install near the capillary in STHAC in order to reduce risk factor. • R290 leaking rate was firstly measured by QLNM before and after the installation a solenoid valve. - Abstract: As a high-profile replacement for R22 split type household air conditioner (STHAC), R290 has several advantages in terms of thermodynamic properties, environmental characteristics, and cost. However, the obvious shortcoming of R290 is its flammability, which has a potential fire risk to the building. At present, the most important measure to ensure the safety of a R290 STHAC is to limit the refrigerant charge by domestic and international standards. But in fact, when the leakage of R290 occur from a STHAC, the distribution of R290 in STHAC, and the leaking rate also will seriously affect the safety of an R290 STHAC. In this study, a new quasi-liquid nitrogen method (QLNM) has been proposed in order to investigate the refrigerant distribution in R290 STHACs and the leaking rate under various conditions, and the experiments have been conducted. The experimental results of distribution proved the validation of the QLNM and showed that a large portion of the refrigerant distributed in the condenser when the air conditioner is on running stage and the refrigerant will migrate from the condenser to the evaporator when the air conditioner is on closed stage. Based on this, the installation of a solenoid valve near the capillary has been proposed. The comparison of experimental results of R290 leaking rate before and after the installation of a solenoid valve showed it will obviously reduce the leaking rate and thereby improve the safety of the R290 STHACs.

  19. Impacts of soil conditioners and water table management on phosphorus loss in tile drainage from a clay loam soil.

    Science.gov (United States)

    Zhang, T Q; Tan, C S; Zheng, Z M; Welacky, T W; Reynolds, W D

    2015-03-01

    Adoption of waste-derived soil conditioners and refined water management can improve soil physical quality and crop productivity of fine-textured soils. However, the impacts of these practices on water quality must be assessed to ensure environmental sustainability. We conducted a study to determine phosphorus (P) loss in tile drainage as affected by two types of soil conditioners (yard waste compost and swine manure compost) and water table management (free drainage and controlled drainage with subirrigation) in a clay loam soil under corn-soybean rotation in a 4-yr period from 1999 to 2003. Tile drainage flows were monitored and sampled on a year-round continuous basis using on-site auto-sampling systems. Water samples were analyzed for dissolved reactive P (DRP), particulate P (PP), and total P (TP). Substantially greater concentrations and losses of DRP, PP, and TP occurred with swine manure compost than with control and yard waste compost regardless of water table management. Compared with free drainage, controlled drainage with subirrigation was an effective way to reduce annual and cumulative losses of DRP, PP, and TP in tile drainage through reductions in flow volume and P concentration with control and yard waste compost but not with swine manure compost. Both DRP and TP concentrations in tile drainage were well above the water quality guideline for P, affirming that subsurface loss of P from fine-textured soils can be one critical source for freshwater eutrophication. Swine manure compost applied as a soil conditioner must be optimized by taking water quality impacts into consideration. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  20. ac propulsion system for an electric vehicle

    Science.gov (United States)

    Geppert, S.

    1980-01-01

    It is pointed out that dc drives will be the logical choice for current production electric vehicles (EV). However, by the mid-80's, there is a good chance that the price and reliability of suitable high-power semiconductors will allow for a competitive ac system. The driving force behind the ac approach is the induction motor, which has specific advantages relative to a dc shunt or series traction motor. These advantages would be an important factor in the case of a vehicle for which low maintenance characteristics are of primary importance. A description of an EV ac propulsion system is provided, taking into account the logic controller, the inverter, the motor, and a two-speed transmission-differential-axle assembly. The main barrier to the employment of the considered propulsion system in EV is not any technical problem, but inverter transistor cost.

  1. Superconducting three element synchronous ac machine

    International Nuclear Information System (INIS)

    Boyer, L.; Chabrerie, J.P.; Mailfert, A.; Renard, M.

    1975-01-01

    There is a growing interest in ac superconducting machines. Of several new concepts proposed for these machines in the last years one of the most promising seems to be the ''three elements'' concept which allows the cancellation of the torque acting on the superconducting field winding, thus overcoming some of the major contraints. This concept leads to a device of induction-type generator. A synchronous, three element superconducting ac machine is described, in which a room temperature, dc fed rotating winding is inserted between the superconducting field winding and the ac armature. The steady-state machine theory is developed, the flux linkages are established, and the torque expressions are derived. The condition for zero torque on the field winding, as well as the resulting electrical equations of the machine, are given. The theoretical behavior of the machine is studied, using phasor diagrams and assuming for the superconducting field winding either a constant current or a constant flux condition

  2. 21 CFR 886.4440 - AC-powered magnet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and remove...

  3. Proposal of digital interface for the system of the air conditioner's remote control: analysis of the system of feedback.

    Science.gov (United States)

    da Silva de Queiroz Pierre, Raisa; Kawada, Tarô Arthur Tavares; Fontes, André Guimarães

    2012-01-01

    Develop a proposal of digital interface for the system of the remote control, that functions as support system during the manipulation of air conditioner adjusted for the users in general, from ergonomic parameters, objectifying the reduction of the problems faced for the user and improving the process. 20 people with questionnaire with both qualitative and quantitative level. Linear Method consists of a sequence of steps in which the input of one of them depends on the output from the previous one, although they are independent. The process of feedback, when necessary, must occur within each step separately.

  4. Adhesive bonding of resin composite to various titanium surfaces using different metal conditioners and a surface modification system

    Directory of Open Access Journals (Sweden)

    Hercules Jorge ALMILHATTI

    2013-12-01

    Full Text Available Objective: This study evaluated the effect of three metal conditioners on the shear bond strength (SBS of a prosthetic composite material to cpTi grade I having three surface treatments. Material and Methods: One hundred sixty eight rivet-shaped specimens (8.0x2.0 mm were cast and subjected to polishing (P or sandblasting with either 50 mm (50SB or 250 mm (250SB Al2O3. The metal conditioners Metal Photo Primer (MPP, Cesead II Opaque Primer (OP, Targis Link (TL, and one surface modification system Siloc (S, were applied to the specimen surfaces, which were covered with four 1-mm thick layers of resin composite. The resin layers were exposed to curing light for 90 s separately. Seven specimens from each experimental group were stored in water at 37ºC for 24 h while the other 7 specimens were subjected to 5,000 thermal cycles consisting of water baths at 4ºC and 60ºC (n=7. All specimens were subjected to SBS test (0.5 mm/min until failure occurred, and further 28 specimens were analyzed using scanning electron microscope (SEM and X-ray energy-dispersive spectroscopy (EDS. Data were analyzed by 3-way ANOVA followed by post-hoc Tukey's test (α=0.05. Results: On 50SB surfaces, OP groups showed higher SBS means than MPP (P<0.05, while no significant difference was found among OP, S, and TL groups. On 250SB surfaces, OP and TL groups exhibited higher SBS than MPP and S (P<0.05. No significant difference in SBS was found between OP and TL groups nor between MPP and S groups. The use of conditioners on 250SB surfaces resulted in higher SBS means than the use of the same products on 50SB surfaces (P<0.05. Conclusion: Sandblasting associated with the use of metal conditioners improves SBS of resin composites to cpTi.

  5. AC conductivity for a holographic Weyl semimetal

    Energy Technology Data Exchange (ETDEWEB)

    Grignani, Gianluca; Marini, Andrea; Peña-Benitez, Francisco; Speziali, Stefano [Dipartimento di Fisica e Geologia, Università di Perugia,I.N.F.N. Sezione di Perugia,Via Pascoli, I-06123 Perugia (Italy)

    2017-03-23

    We study the AC electrical conductivity at zero temperature in a holographic model for a Weyl semimetal. At small frequencies we observe a linear dependence in the frequency. The model shows a quantum phase transition between a topological semimetal (Weyl semimetal phase) with a non vanishing anomalous Hall conductivity and a trivial semimetal. The AC conductivity has an intermediate scaling due to the presence of a quantum critical region in the phase diagram of the system. The phase diagram is reconstructed using the scaling properties of the conductivity. We compare with the experimental data of https://www.doi.org/10.1103/PhysRevB.93.121110 obtaining qualitative agreement.

  6. Mapa acústico parcial de Benetusser

    OpenAIRE

    MORILLA CASTELLANOS, EMILIO

    2012-01-01

    Se establece el mapa de ruido del municipio de Benetússer para evaluar y conocer su exposición al ruido ambiental y así poder dar cumplimiento a la Directiva Europea sobre Gestión y Evaluación de Ruido Ambiental (2002/49/CE) y a la Ley nacional 37/2003 del Ruido. Los mapas estratégicos de ruido nos aportan la información fundamental para diagnosticar la situación acústica y para la gestión del ruido ambiental. Morilla Castellanos, E. (2012). Mapa acústico parcial de Benetusser. http://h...

  7. Preliminary study on AC superconducting machines

    International Nuclear Information System (INIS)

    Yamamoto, M.; Ishigohka, T.; Shimohka, T.; Mizukami, N.; Yamaguchi, M.

    1988-01-01

    This paper describes the issues involved in developing AC superconducting machines. In the first phase, as a preliminary experiment, a 4kVa AC superconducting coil which employs 100A class 50/60Hz superconductors is made and tested. And, in the second phase, as an extension of the 4kVa coil, a model superconducting transformer is made and examined. The transformer has a novel quench protection system with an auxiliary coil only in the low voltage side. The behavior of the overcurrent protection system is confirmed

  8. Nuclear structure of {sup 231}Ac

    Energy Technology Data Exchange (ETDEWEB)

    Boutami, R. [Instituto de Estructura de la Materia, CSIC, Serrano 113 bis, E-28006 Madrid (Spain); Borge, M.J.G. [Instituto de Estructura de la Materia, CSIC, Serrano 113 bis, E-28006 Madrid (Spain)], E-mail: borge@iem.cfmac.csic.es; Mach, H. [Department of Radiation Sciences, ISV, Uppsala University, SE-751 21 Uppsala (Sweden); Kurcewicz, W. [Department of Physics, University of Warsaw, Pl-00 681 Warsaw (Poland); Fraile, L.M. [Departamento Fisica Atomica, Molecular y Nuclear, Facultad CC. Fisicas, Universidad Complutense, E-28040 Madrid (Spain); ISOLDE, PH Department, CERN, CH-1211 Geneva 23 (Switzerland); Gulda, K. [Department of Physics, University of Warsaw, Pl-00 681 Warsaw (Poland); Aas, A.J. [Department of Chemistry, University of Oslo, PO Box 1033, Blindern, N-0315 Oslo (Norway); Garcia-Raffi, L.M. [Instituto de Fisica Corpuscular, CSIC - Universidad de Valencia, Apdo. 22805, E-46071 Valencia (Spain); Lovhoiden, G. [Department of Physics, University of Oslo, PO Box 1048, Blindern, N-0316 Oslo (Norway); Martinez, T.; Rubio, B.; Tain, J.L. [Instituto de Fisica Corpuscular, CSIC - Universidad de Valencia, Apdo. 22805, E-46071 Valencia (Spain); Tengblad, O. [Instituto de Estructura de la Materia, CSIC, Serrano 113 bis, E-28006 Madrid (Spain); ISOLDE, PH Department, CERN, CH-1211 Geneva 23 (Switzerland)

    2008-10-15

    The low-energy structure of {sup 231}Ac has been investigated by means of {gamma} ray spectroscopy following the {beta}{sup -} decay of {sup 231}Ra. Multipolarities of 28 transitions have been established by measuring conversion electrons with a MINI-ORANGE electron spectrometer. The decay scheme of {sup 231}Ra {yields}{sup 231}Ac has been constructed for the first time. The Advanced Time Delayed {beta}{gamma}{gamma}(t) method has been used to measure the half-lives of five levels. The moderately fast B(E1) transition rates derived suggest that the octupole effects, albeit weak, are still present in this exotic nucleus.

  9. Control of Power Converters in AC Microgrids

    DEFF Research Database (Denmark)

    Rocabert, Joan; Luna, Alvaro; Blaabjerg, Frede

    2012-01-01

    The enabling of ac microgrids in distribution networks allows delivering distributed power and providing grid support services during regular operation of the grid, as well as powering isolated islands in case of faults and contingencies, thus increasing the performance and reliability of the ele......The enabling of ac microgrids in distribution networks allows delivering distributed power and providing grid support services during regular operation of the grid, as well as powering isolated islands in case of faults and contingencies, thus increasing the performance and reliability...

  10. Statistical time lags in ac discharges

    International Nuclear Information System (INIS)

    Sobota, A; Kanters, J H M; Van Veldhuizen, E M; Haverlag, M; Manders, F

    2011-01-01

    The paper presents statistical time lags measured for breakdown events in near-atmospheric pressure argon and xenon. Ac voltage at 100, 400 and 800 kHz was used to drive the breakdown processes, and the voltage amplitude slope was varied between 10 and 1280 V ms -1 . The values obtained for the statistical time lags are roughly between 1 and 150 ms. It is shown that the statistical time lags in ac-driven discharges follow the same general trends as the discharges driven by voltage of monotonic slope. In addition, the validity of the Cobine-Easton expression is tested at an alternating voltage form.

  11. Statistical time lags in ac discharges

    Energy Technology Data Exchange (ETDEWEB)

    Sobota, A; Kanters, J H M; Van Veldhuizen, E M; Haverlag, M [Eindhoven University of Technology, Department of Applied Physics, Postbus 513, 5600MB Eindhoven (Netherlands); Manders, F, E-mail: a.sobota@tue.nl [Philips Lighting, LightLabs, Mathildelaan 1, 5600JM Eindhoven (Netherlands)

    2011-04-06

    The paper presents statistical time lags measured for breakdown events in near-atmospheric pressure argon and xenon. Ac voltage at 100, 400 and 800 kHz was used to drive the breakdown processes, and the voltage amplitude slope was varied between 10 and 1280 V ms{sup -1}. The values obtained for the statistical time lags are roughly between 1 and 150 ms. It is shown that the statistical time lags in ac-driven discharges follow the same general trends as the discharges driven by voltage of monotonic slope. In addition, the validity of the Cobine-Easton expression is tested at an alternating voltage form.

  12. Natural refrigerants for air conditioners in passenger cars. A contribution to climate protection. Background; Natuerliche Kaeltemittel fuer PKW-Klimaanlagen. Ein Beitrag zum Klimaschutz. Hintergrund

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Gabriele; Plehn, Wolfgang

    2010-09-15

    Air conditioners in passenger cars contain a refrigerant which significantly increases the greenhouse effect. Currently about 30 % of global emissions of partially fluorinated hydrocarbons originate from these air conditioners. According to the directive 2006/40/EC, this refrigerant must be replaced by a less harmful substance. Under this aspect, the contribution under consideration initially reports on the stock and level of air conditioning of passenger cars as well as on the refrigerant tetrafluoroethane. Subsequently, refrigerants for air conditioning of passenger cars such as carbon dioxide, 1.1-difluoroethane and 2,3,3,3-tetrafluoro propylene are described. Overall, the refrigerant carbon dioxide is the best alternative for mobile air conditioning.

  13. Investigate Transient Behaviours and Select Appropriate Fault Protection Solutions of Uni-grounded AC Microgrids

    Directory of Open Access Journals (Sweden)

    Duong Minh Bui

    2016-03-01

    Full Text Available Transient situations of a uni-grounded low-voltage AC microgrid are simulated in this paper, which include different fault tests and operation transition test between the grid-connected and islanded modes of the uni-grounded microgrid. Based on transient simulation results, available fault protection methods are proposed for the main and back-up protection of a uni-grounded AC microgrid. Main contributions of this paper are (i analysing transient responses of a typically uni-grounded lowvoltage AC microgrid from line-to-line, single line-to-ground, three-phase faults and a microgrid operation transition test; and (ii proposing available fault protection methods for uni-grounded AC microgrids, such as non-directional/directional overcurrent protection solutions, under/over voltage protection solutions, differential protection, voltage-restrained overcurrent protection, and other protection principles not based on high fault currents (e.g. total harmonic distortion detection of phase currents and voltages, or protection methods using symmetrical sequence components of current and voltage.

  14. A Generalised Fault Protection Structure Proposed for Uni-grounded Low-Voltage AC Microgrids

    Science.gov (United States)

    Bui, Duong Minh; Chen, Shi-Lin; Lien, Keng-Yu; Jiang, Jheng-Lun

    2016-04-01

    This paper presents three main configurations of uni-grounded low-voltage AC microgrids. Transient situations of a uni-grounded low-voltage (LV) AC microgrid (MG) are simulated through various fault tests and operation transition tests between grid-connected and islanded modes. Based on transient simulation results, available fault protection methods are proposed for main and back-up protection of a uni-grounded AC microgrid. In addition, concept of a generalised fault protection structure of uni-grounded LVAC MGs is mentioned in the paper. As a result, main contributions of the paper are: (i) definition of different uni-grounded LVAC MG configurations; (ii) analysing transient responses of a uni-grounded LVAC microgrid through line-to-line faults, line-to-ground faults, three-phase faults and a microgrid operation transition test, (iii) proposing available fault protection methods for uni-grounded microgrids, such as: non-directional or directional overcurrent protection, under/over voltage protection, differential current protection, voltage-restrained overcurrent protection, and other fault protection principles not based on phase currents and voltages (e.g. total harmonic distortion detection of currents and voltages, using sequence components of current and voltage, 3I0 or 3V0 components), and (iv) developing a generalised fault protection structure with six individual protection zones to be suitable for different uni-grounded AC MG configurations.

  15. Multi-phase AC/AC step-down converter for distribution systems

    Science.gov (United States)

    Aeloiza, Eddy C.; Burgos, Rolando P.

    2017-10-25

    A step-down AC/AC converter for use in an electric distribution system includes at least one chopper circuit for each one of a plurality of phases of the AC power, each chopper circuit including a four-quadrant switch coupled in series between primary and secondary sides of the chopper circuit and a current-bidirectional two-quadrant switch coupled between the secondary side of the chopper circuit and a common node. Each current-bidirectional two-quadrant switch is oriented in the same direction, with respect to the secondary side of the corresponding chopper circuit and the common node. The converter further includes a control circuit configured to pulse-width-modulate control inputs of the switches, to convert a first multiphase AC voltage at the primary sides of the chopper circuits to a second multiphase AC voltage at the secondary sides of the chopper circuits, the second multiphase AC voltage being lower in voltage than the first multiphase AC voltage.

  16. AC loss in superconducting tapes and cables

    NARCIS (Netherlands)

    Oomen, M.P.

    2000-01-01

    The present study discusses the AC loss in high-temperature superconductors. Superconducting materials with a relatively high critical temperature were discovered in 1986. They are presently developed for use in large-scale power-engineering devices such as power-transmission cables, transformers

  17. Ac-dc converter firing error detection

    International Nuclear Information System (INIS)

    Gould, O.L.

    1996-01-01

    Each of the twelve Booster Main Magnet Power Supply modules consist of two three-phase, full-wave rectifier bridges in series to provide a 560 VDC maximum output. The harmonic contents of the twelve-pulse ac-dc converter output are multiples of the 60 Hz ac power input, with a predominant 720 Hz signal greater than 14 dB in magnitude above the closest harmonic components at maximum output. The 720 Hz harmonic is typically greater than 20 dB below the 500 VDC output signal under normal operation. Extracting specific harmonics from the rectifier output signal of a 6, 12, or 24 pulse ac-dc converter allows the detection of SCR firing angle errors or complete misfires. A bandpass filter provides the input signal to a frequency-to-voltage converter. Comparing the output of the frequency-to-voltage converter to a reference voltage level provides an indication of the magnitude of the harmonics in the ac-dc converter output signal

  18. THE ACS NEARBY GALAXY SURVEY TREASURY

    International Nuclear Information System (INIS)

    Dalcanton, Julianne J.; Williams, Benjamin F.; Rosema, Keith; Gogarten, Stephanie M.; Christensen, Charlotte; Gilbert, Karoline; Hodge, Paul; Seth, Anil C.; Dolphin, Andrew; Holtzman, Jon; Skillman, Evan D.; Weisz, Daniel; Cole, Andrew; Girardi, Leo; Karachentsev, Igor D.; Olsen, Knut; Freeman, Ken; Gallart, Carme; Harris, Jason; De Jong, Roelof S.

    2009-01-01

    The ACS Nearby Galaxy Survey Treasury (ANGST) is a systematic survey to establish a legacy of uniform multi-color photometry of resolved stars for a volume-limited sample of nearby galaxies (D 4 in luminosity and star formation rate. The survey data consist of images taken with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST), supplemented with archival data and new Wide Field Planetary Camera 2 (WFPC2) imaging taken after the failure of ACS. Survey images include wide field tilings covering the full radial extent of each galaxy, and single deep pointings in uncrowded regions of the most massive galaxies in the volume. The new wide field imaging in ANGST reaches median 50% completenesses of m F475W = 28.0 mag, m F606W = 27.3 mag, and m F814W = 27.3 mag, several magnitudes below the tip of the red giant branch (TRGB). The deep fields reach magnitudes sufficient to fully resolve the structure in the red clump. The resulting photometric catalogs are publicly accessible and contain over 34 million photometric measurements of >14 million stars. In this paper we present the details of the sample selection, imaging, data reduction, and the resulting photometric catalogs, along with an analysis of the photometric uncertainties (systematic and random), for both ACS and WFPC2 imaging. We also present uniformly derived relative distances measured from the apparent magnitude of the TRGB.

  19. Predicting AC loss in practical superconductors

    International Nuclear Information System (INIS)

    Goemoery, F; Souc, J; Vojenciak, M; Seiler, E; Klincok, B; Ceballos, J M; Pardo, E; Sanchez, A; Navau, C; Farinon, S; Fabbricatore, P

    2006-01-01

    Recent progress in the development of methods used to predict AC loss in superconducting conductors is summarized. It is underlined that the loss is just one of the electromagnetic characteristics controlled by the time evolution of magnetic field and current distribution inside the conductor. Powerful methods for the simulation of magnetic flux penetration, like Brandt's method and the method of minimal magnetic energy variation, allow us to model the interaction of the conductor with an external magnetic field or a transport current, or with both of them. The case of a coincident action of AC field and AC transport current is of prime importance for practical applications. Numerical simulation methods allow us to expand the prediction range from simplified shapes like a (infinitely high) slab or (infinitely thin) strip to more realistic forms like strips with finite rectangular or elliptic cross-section. Another substantial feature of these methods is that the real composite structure containing an array of superconducting filaments can be taken into account. Also, the case of a ferromagnetic matrix can be considered, with the simulations showing a dramatic impact on the local field. In all these circumstances, it is possible to indicate how the AC loss can be reduced by a proper architecture of the composite. On the other hand, the multifilamentary arrangement brings about a presence of coupling currents and coupling loss. Simulation of this phenomenon requires 3D formulation with corresponding growth of the problem complexity and computation time

  20. Meso Mechanical Analysis of AC Mixture Response

    NARCIS (Netherlands)

    Woldekidan, M.F.; Huurman, M.; Vaccari, E.; Poot, M.

    2012-01-01

    Ongoing research into performance modeling of Asphalt Concrete (AC) mixtures using meso mechanics approaches is being undertaken at Delft University of Technology (TUD). The approach has already been successfully employed for evaluating the long term performance of porous asphalt concrete. The work

  1. Updating the HST/ACS G800L Grism Calibration

    Science.gov (United States)

    Hathi, Nimish P.; Pirzkal, Norbert; Grogin, Norman A.; Chiaberge, Marco; ACS Team

    2018-06-01

    We present results from our ongoing work on obtaining newly derived trace and wavelength calibrations of the HST/ACS G800L grism and comparing them to previous set of calibrations. Past calibration efforts were based on 2003 observations. New observations of an emission line Wolf-Rayet star (WR96) were recently taken in HST Cycle 25 (PID: 15401). These observations are used to analyze and measure various grism properties, including wavelength calibration, spectral trace/tilt, length/size of grism orders, and spacing between various grism orders. To account for the field dependence, we observe WR96 at 3 different observing positions over the HST/ACS field of view. The three locations are the center of chip 1, the center of chip 2, and the center of the WFC1A-2K subarray (center of WFC Amp A on chip 1). This new data will help us to evaluate any differences in the G800L grism properties compared to previous calibration data, and to apply improved data analysis techniques to update these old measurements.

  2. A novel power control strategy of Modular Multi-level Converter in HVDC-AC hybrid transmission systems for passive networks

    DEFF Research Database (Denmark)

    Hu, Zhenda; Wu, Rui; Yang, Xiaodong

    2014-01-01

    With the development of High Voltage DC Transmission (HVDC) technology, there will be more and more HVDC-AC hybrid transmission system in the world. A basic challenge in HVDC-AC hybrid transmission systems is to optimize the power sharing between DC and AC lines, which become more severe when sup...... control strategy of Modular Multi-level Converter in VSC-HVDC, which can optimize converter output power according to passive network loading variation. Proposal method is studied with a case study of a VSC-HVDC AC hybrid project by PSCAD/EMTDC simulations....

  3. The design of the motor bracket for reduction of structure-borne noise in package air-conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Hyoun Jin; Lee, Sung Jin; Oh, Jae Eung [Hanyang University, Seoul (Korea, Republic of); Kang, Tae Ho [WiniaMando, Asan (Korea, Republic of); Lee, Jung Yoon [Kyonggi University, Suwon (Korea, Republic of)

    2006-02-15

    As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the air-conditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is developed. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as Operational Deflection Shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of Experiments) in the noise and vibration point a view.

  4. Performance evaluation of a stack cooling system using CO{sub 2} air conditioner in fuel cell vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Chul; Won, Jong Phil [Thermal Management Research Center, Korea Automotive Technology Institute, Chungnam 330-912 (Korea); Park, Yong Sun; Lim, Tae Won [Corporate Research and Development Division, Hyundai-Kia Motors, Gyeonggi 449-912 (Korea); Kim, Min Soo [School of Mechanical and Aerospace Engineering, Seoul National University, Seoul 151-744 (Korea)

    2009-01-15

    A relation between the heat release from a fuel cell stack and an air conditioning system's performance was investigated. The air conditioning system installed in a fuel cell vehicle can be used for stack cooling when additional stack heat release is required over a fixed radiator capacity during high vehicle power generation. This study investigated the performance of a stack cooling system using CO{sub 2} air conditioner at various operating conditions. Also, the heat releasing effectiveness and mutual interference were analyzed and compared with those for the conventional radiator cooling system with/without cabin cooling. When the radiator coolant inlet temperature and flow rate were 65 C and 80 L/min, respectively, for the outdoor air inlet speed of 5 m/s, the heat release of the stack cooling system with the aid of CO{sub 2} air conditioner increased up to 36% more than that of the conventional radiator cooling system with cabin cooling. Furthermore, this increased by 7% versus the case without cabin cooling. (author)

  5. Effects of ejector geometries on performance of ejector-expansion R410A air conditioner considering cooling seasonal performance factor

    International Nuclear Information System (INIS)

    Jeon, Yongseok; Jung, Jongho; Kim, Dongwoo; Kim, Sunjae; Kim, Yongchan

    2017-01-01

    Highlights: •The performance of an ejector-expansion R410A air conditioner is measured. •The effect of ejector geometries on the COP and CSPF is analyzed. •The mixing-section diameter of the ejector is optimized based on the CSPF. •The mixing-section diameter is optimized based on the climatic conditions. -- Abstract: The objective of this study was to investigate the effects of ejector geometries on the performance of an ejector-expansion air conditioner (EEAC) considering the cooling seasonal performance factor (CSPF). The performance of the EEAC using R410A was measured and analyzed by varying the compressor speed, outdoor-bin temperature, operating pressures, nozzle-throat diameter, and mixing-section diameter. The EEAC in the medium-capacity mode exhibited maximum coefficient of performance (COP) improvement, i.e., 7.5%, over the baseline (conventional) cycle. The optimum mixing-section diameter was determined to be 9 mm based on the CSPF. In addition, the optimum mixing-section diameter increased with an increase in the annual average outdoor temperature. The CSPF of the EEAC with the optimized mixing-section diameter improved in the range of 16.0–20.3% over the baseline cycle depending on the climatic conditions.

  6. A review on test procedure, energy efficiency standards and energy labels for room air conditioners and refrigerator-freezers

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Saidur, R. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2010-09-15

    Air conditioners and refrigerator-freezers are major energy users in a household environment and hence efficiency improvement of these appliances can be considered as an important step to reduce their energy consumption along with environmental pollution prevention. Energy efficiency standards and labels are commonly used tools to reduce the energy uses for household appliances for many countries around the world. The first step towards adopting energy efficiency standards is to establish a test procedure for rating and testing of an appliance. It may be mentioned that an energy test procedure is the technical foundation for energy efficiency standards, energy labels, and other related programs. This paper reviews requirements and specifications of various international test standards for testing and rating of room air conditioners and refrigerators. A review on the development of the energy efficiency standards has been provided as well. Finally, energy labels that provide some useful information for identifying energy efficient products have been reviewed for these appliances. It may be stated that the review will be useful for the developing countries who wish to develop these energy savings strategies. It is also expected to be useful to revise the existing strategies for a few selected countries who already implemented these strategies earlier. (author)

  7. Performance of a prototype micro wind turbine in the manmade wind field from air conditioner of buildings

    Directory of Open Access Journals (Sweden)

    K. H. Goh

    2012-03-01

    Full Text Available Harnessing waste energy from the manmade air fields of buildings presents a new area of renewable energy to explore. Due to the unpredictability of the natural wind, this study is to evaluate the practicality for harnessing waste energy from the air conditioner exhaust units which are a more constant and predictable source available in the buildings. A prototype of the micro wind turbine has been designed to minimize the negative effect of the exhaust sources. After the micro wind turbine was manufactured, the performance of the turbine was tested in the selected air conditioner exhaust unit. Increasing the rotor solidity and decreasing the resistance of the generator contribute to improved starting torque and decreased generator break in torque respectively in the design. The power generation of the micro wind turbine increases with an increase of the rotor speed. The 24-hour operation of the prototype presents an observation for both exhaust performance and power generation prediction when the prototype is mounted on the exhaust unit.

  8. Effectiveness of finish materials and room air-conditioner on the reduction of indoor radon concentration in Hong Kong

    International Nuclear Information System (INIS)

    Ma, A.K.; Man, C.K.; Ho, E.; Pang, S.W.

    1995-01-01

    Four different kinds of finish material were investigated: wallpaper, paint, plaster and tile. When applied to the bare concrete walls of uninhabited rooms in flats of a building under construction, all of them were found to reduce indoor radon concentration. The magnitude of reduction by these finish materials ranged from 20% to 80%. Wallpaper was found to provide the best protection against radon emission from bare concrete walls in a bedroom with a size of 19.3 m 3 . Wallpaper can reduce the indoor radon concentration about twice as much as paint (water-based) or plaster in this investigation. Tile was also found to be a good material against radon emission from concrete walls in a bathroom with a size of 6.3 m 3 . Indoor radon concentration was found to decrease with elevation from the ground level, and was affected strongly by mechanical ventilation. Another 30% to 50% reduction in indoor radon concentration in addition to finish material can be achieved by a room air-conditioner. It was also found that indoor radon concentrations were not affected by turning the fresh air shutter to the 'on' or 'off' position in the room air-conditioner. (author)

  9. Experimental investigations on automobile air conditioners working with R134a and R290/R600a as an alternative

    Directory of Open Access Journals (Sweden)

    Kandhaswamy Karthikeyan

    2017-01-01

    Full Text Available In this work, the performance of R134a based automobile air conditioning system has been evaluated by retrofitted with R290/R600a mixture (in the ratio of 50:50, by mass, as an alternative. The performance was evaluated at five different operating speeds (1000, 1500, 2000, 2500, and 3000, which covers the entire range of working conditions with four different cabin load (100, 200, 300, and 400 W. The condenser inlet air temperature was varied in the range between 30 and 50°C, which covers the entire climatic variations in Coimbatore city of India. The performance characteristics such as, refrigerating effect, coefficient of performance, compressor power consumption, and compressor discharge temperatures were considered for comparison. The results showed that, hydrocarbon mixture has faster cooling rate due to its high latent heat of vaporization, 5% higher coefficient of performance due to higher refrigeration effect, 8-10 K lower compressor discharge temperature due to its lower specific heat ratio with 5% lower compressor power consumption due to its lower viscosity and lower liquid density. The charge requirement of R290/R600a mixture is about 50% less compared to R134a. However, the mixture composition is considered as an interment replacement in automobile air conditioners due to composition shift under leak-age conditions. Hence, R290/R600a mixture is considered as an interim energy efficient and environment friendly option in R134a automobile air conditioners to extend its life.

  10. The design of the motor bracket for reduction of structure-borne noise in package air-conditioner

    International Nuclear Information System (INIS)

    Sim, Hyoun Jin; Lee, Sung Jin; Oh, Jae Eung; Kang, Tae Ho; Lee, Jung Yoon

    2006-01-01

    As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the air-conditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is developed. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as Operational Deflection Shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of Experiments) in the noise and vibration point a view

  11. Effect of heat recovery water heater system on the performance of residential split air conditioner using hydrocarbon refrigerant (HCR22)

    Science.gov (United States)

    Aziz, A.; Thalal; Amri, I.; Herisiswanto; Mainil, A. K.

    2017-09-01

    This This paper presents the performance of residential split air conditioner (RSAC) using hydrocarbon refrigerant (HCR22) as the effect on the use of heat recovery water heater system (HRWHS). In this study, RSAC was modified with addition of dummy condenser (trombone coil type) as heat recovery water heater system (HRWHS). This HRWHS is installed between a compressor and a condenser by absorbing a part of condenser waste heat. The results show that RSAC with HRWHS is adequate to generate hot water with the temperature range about 46.58˚C - 48.81˚C when compared to without HRWHS and the use of dummy condenser does not give significant effect to the split air conditioner performance. When the use of HRWHS, the refrigerant charge has increase about 19.05%, the compressor power consumption has slightly increase about 1.42% where cooling capacity almost the same with slightly different about 0.39%. The condenser heat rejection is lower about 2.68% and the COP has slightly increased about 1.05% when compared to without HRWHS. The use of HRWHS provide free hot water, it means there is energy saving for heating water without negative impact to the system performance of RSAC.

  12. Study on the complexity pricing game and coordination of the duopoly air conditioner market with disturbance demand

    Science.gov (United States)

    Ma, Junhai; Xie, Lei

    2016-03-01

    The paper focuses on the dynamic pricing game of the duopoly air conditioner market with disturbance in demand and analyzes the influence of disturbance on the dynamic game system. Considering the demand for products, such as air conditioner, varies with different seasons, we assume three cases based on the condition of disturbance, including growth market (Case 1), declining market (Case 2) and completely random market (Case 3). By analyzing these three cases and making comparison among them, the paper shows that the growth market is more sensitive to the changing parameters such as the adjustment variable and the competitive factor than the declining market. It is more difficult to keep the system stable in a growth market. Although the demand is completely random, the dynamic system can reach a stable state, on condition that the adjustment variable is small enough. The results also indicate that the bullwhip effect between the order quantity and the actual demand is weakened gradually along with the price adjustment.

  13. Your employees: the front line in cyber security

    OpenAIRE

    Ashenden, D

    2016-01-01

    First published in The Chemical Engineer and reproduced by Crest - Centre for Research and Evidence on Security Threats, 26/01/2016 (https://crestresearch.ac.uk/comment/employees-front-line-cyber-security/)

  14. Performance evaluation of a solar energy assisted hybrid desiccant air conditioner integrated with HDH desalination system

    International Nuclear Information System (INIS)

    Kabeel, A.E.; Abdelgaied, Mohamed; Zakaria, Yehya

    2017-01-01

    Highlights: • The performance of a solar hybrid air conditioner integrated with HDH desalination system is numerically investigated. • For increase the regeneration air from 70 to 130 m 3 /h, the distillate water productivity increases from 2.988 to 4.78 L/h. • For increase the regeneration air from 70 to 130 m 3 /h, COP overall daily decreases from 4.66 to 3.386. • For increases the regeneration air temperature from 75 to 95 °C, the distillate water increases from 3.1752 to 5.011 L/h. • For increases the regeneration air temperature from 75 to 95 °C, COP overall daily decreases from 4.392 to 3.636. - Abstract: In this study, the performances of a solar energy assisted hybrid desiccant air conditioning system integrated with humidification–dehumidification (HDH) desalination system are numerically investigated. The aim of this study is to benefit from the temperature rise of the regeneration air outside of the desiccant conditioning system as well as the water vapor content in this regeneration air by feeding it to the humidification-dehumidification water desalination unit to produce distillate water. The distillate water productivity, human thermal comfort issues, and energy saving represent the main objective of the present numerical study. The simulated results developed for subsystems are validated with the published experimental results. The effects of regeneration air temperature and flow rate on supply cooled air temperature, distillate water productivity, the cooling coefficient of performance and overall daily coefficient of performance of the proposed system are investigated. The results show that (i) the distillate water productivity increases from 3.175 to 5.011 L/h and overall daily coefficient of performance decreases from 4.392 to 3.636 with increasing the regeneration air temperature from 75 to 95 as (ii) the increase in the regeneration air flow rate from 70 to 130 m 3 /h, increases the distillate water productivity from 2.988 to 4

  15. Future emissions and atmospheric fate of HFC-1234yf from mobile air conditioners in Europe.

    Science.gov (United States)

    Henne, Stephan; Shallcross, Dudley E; Reimann, Stefan; Xiao, Ping; Brunner, Dominik; O'Doherty, Simon; Buchmann, Brigitte

    2012-02-07

    HFC-1234yf (2,3,3,3-tetrafluoropropene) is under discussion for replacing HFC-134a (1,1,1,2-tetrafluoroethane) as a cooling agent in mobile air conditioners (MACs) in the European vehicle fleet. Some HFC-1234yf will be released into the atmosphere, where it is almost completely transformed to the persistent trifluoroacetic acid (TFA). Future emissions of HFC-1234yf after a complete conversion of the European vehicle fleet were assessed. Taking current day leakage rates and predicted vehicle numbers for the year 2020 into account, European total HFC-1234yf emissions from MACs were predicted to range between 11.0 and 19.2 Gg yr(-1). Resulting TFA deposition rates and rainwater concentrations over Europe were assessed with two Lagrangian chemistry transport models. Mean European summer-time TFA mixing ratios of about 0.15 ppt (high emission scenario) will surpass previously measured levels in background air in Germany and Switzerland by more than a factor of 10. Mean deposition rates (wet + dry) of TFA were estimated to be 0.65-0.76 kg km(-2) yr(-1), with a maxium of ∼2.0 kg km(-2) yr(-1) occurring in Northern Italy. About 30-40% of the European HFC-1234yf emissions were deposited as TFA within Europe, while the remaining fraction was exported toward the Atlantic Ocean, Central Asia, Northern, and Tropical Africa. Largest annual mean TFA concentrations in rainwater were simulated over the Mediterranean and Northern Africa, reaching up to 2500 ng L(-1), while maxima over the continent of about 2000 ng L(-1) occurred in the Czech Republic and Southern Germany. These highest annual mean concentrations are at least 60 times lower than previously determined to be a safe level for the most sensitive aquatic life-forms. Rainwater concentrations during individual rain events would still be 1 order of magnitude lower than the no effect level. To verify these results future occasional sampling of TFA in the atmospheric environment should be considered. If future HFC-1234yf

  16. Assay Methods for ACS Activity and ACS Phosphorylation by MAP Kinases In Vitro and In Vivo.

    Science.gov (United States)

    Han, Xiaomin; Li, Guojing; Zhang, Shuqun

    2017-01-01

    Ethylene, a gaseous phytohormone, has profound effects on plant growth, development, and adaptation to the environment. Ethylene-regulated processes begin with the induction of ethylene biosynthesis. There are two key steps in ethylene biosynthesis. The first is the biosynthesis of 1-aminocyclopropane-1-carboxylic acid (ACC) from S-Adenosyl-Methionine (SAM), a common precursor in many metabolic pathways, which is catalyzed by ACC synthase (ACS). The second is the oxidative cleavage of ACC to form ethylene under the action of ACC oxidase (ACO). ACC biosynthesis is the committing and generally the rate-limiting step in ethylene biosynthesis. As a result, characterizing the cellular ACS activity and understanding its regulation are important. In this chapter, we detail the methods used to measure, (1) the enzymatic activity of both recombinant and native ACS proteins, and (2) the phosphorylation of ACS protein by mitogen-activated protein kinases (MAPKs) in vivo and in vitro.

  17. High voltage AC/AC electrochemical capacitor operating at low temperature in salt aqueous electrolyte

    Science.gov (United States)

    Abbas, Qamar; Béguin, François

    2016-06-01

    We demonstrate that an activated carbon (AC)-based electrochemical capacitor implementing aqueous lithium sulfate electrolyte in 7:3 vol:vol water/methanol mixture can operate down to -40 °C with good electrochemical performance. Three-electrode cell investigations show that the faradaic contributions related with hydrogen chemisorption in the negative AC electrode are thermodynamically unfavored at -40 °C, enabling the system to work as a typical electrical double-layer (EDL) capacitor. After prolonged floating of the AC/AC capacitor at 1.6 V and -40°C, the capacitance, equivalent series resistance and efficiency remain constant, demonstrating the absence of ageing related with side redox reactions at this temperature. Interestingly, when temperature is increased back to 24 °C, the redox behavior due to hydrogen storage reappears and the system behaves as a freshly prepared one.

  18. Digital model for harmonic interactions in AC/DC/AC systems

    Energy Technology Data Exchange (ETDEWEB)

    Guarini, A P; Rangel, R D; Pilotto, L A.S.; Pinto, R J; Passos, Junior, R [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil)

    1994-12-31

    The main purpose of this paper is to present a model for calculation of HVdc converter harmonics taking into account the influence of the harmonic interactions between the ac systems in dc link transmissions. The ideas and methodologies used in the model development take into account the dc current ripple and ac voltage distortion in the ac systems. The theory of switching functions is applied to contemplate for the frequency conversions between the ac and dc sides, in an iterative process. It is possible then to obtain, even in balanced situations, non-characteristic harmonics that are produced by frequencies originated in the other terminal, which can be significant in a strongly coupled system, such as back-to-back configuration. (author) 9 refs., 3 figs.

  19. Engineering cotton (Gossypium hirsutum L.) for resistance to cotton leaf curl disease using viral truncated AC1 DNA sequences.

    Science.gov (United States)

    Hashmi, Jamil A; Zafar, Yusuf; Arshad, Muhammad; Mansoor, Shahid; Asad, Shaheen

    2011-04-01

    Several important biological processes are performed by distinct functional domains found on replication-associated protein (Rep) encoded by AC1 of geminiviruses. Two truncated forms of replicase (tAC1) gene, capable of expressing only the N-terminal 669 bp (5'AC1) and C-terminal 783 bp (3'AC1) nucleotides cloned under transcriptional control of the CaMV35S were introduced into cotton (Gossypium hirsutum L.) using LBA4404 strain of Agrobacterium tumefaciens to make use of an interference strategy for impairing cotton leaf curl virus (CLCuV) infection in transgenic cotton. Compared with nontransformed control, we observed that transgenic cotton plants overexpressing either N-terminal (5'AC1) or C-terminal (3'AC1) sequences confer resistance to CLCuV by inhibiting replication of viral genomic and β satellite DNA components. Molecular analysis by Northern blot hybridization revealed high transgene expression in early and late growth stages associated with inhibition of CLCuV replication. Of the eight T(1) transgenic lines tested, six had delayed and minor symptoms as compared to nontransformed control lines which developed disease symptoms after 2-3 weeks of whitefly-mediated viral delivery. Virus biological assay and growth of T(2) plants proved that transgenic cotton plants overexpressing 5'- and 3'AC1 displayed high resistance level up to 72, 81%, respectively, as compared to non-transformed control plants following inoculation with viruliferous whiteflies giving significantly high cotton seed yield. Progeny analysis of these plants by polymerase chain reaction (PCR), Southern blotting and virus biological assay showed stable transgene, integration, inheritance and cotton leaf curl disease (CLCuD) resistance in two of the eight transgenic lines having single or two transgene insertions. Transgenic cotton expressing partial AC1 gene of CLCuV can be used as virus resistance source in cotton breeding programs aiming to improve virus resistance in cotton crop.

  20. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan; Fridley, David; Zheng, Nina; Pierrot, Andre

    2010-06-07

    consuming products has always been an important component of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor

  1. Approaches to building single-stage AC/AC conversion switch-mode audio power amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    This paper discusses the possible topologies and promising approaches towards direct single-phase AC-AC conversion of the mains voltage for audio applications. When compared to standard Class-D switching audio power amplifiers with a separate power supply, it is expected that direct conversion will provide better efficiency and higher level of integration, leading to lower component count, volume and cost, but at the expense of a minor performance deterioration. (au)

  2. 10 CFR Appendix M to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Consumption of Central Air Conditioners and Heat Pumps 1. DEFINITIONS 2. TESTING CONDITIONS 2.1Test room... more common ducts within each test room that contains multiple indoor coils. At the plane where each...

  3. Design and implementation of co-operative control strategy for hybrid AC/DC microgrids

    Science.gov (United States)

    Mahmud, Rasel

    This thesis is mainly divided in two major sections: 1) Modeling and control of AC microgrid, DC microgrid, Hybrid AC/DC microgrid using distributed co-operative control, and 2) Development of a four bus laboratory prototype of an AC microgrid system. At first, a distributed cooperative control (DCC) for a DC microgrid considering the state-of-charge (SoC) of the batteries in a typical plug-in-electric-vehicle (PEV) is developed. In DC microgrids, this methodology is developed to assist the load sharing amongst the distributed generation units (DGs), according to their ratings with improved voltage regulation. Subsequently, a DCC based control algorithm for AC microgrid is also investigated to improve the performance of AC microgrid in terms of power sharing among the DGs, voltage regulation and frequency deviation. The results validate the advantages of the proposed methodology as compared to traditional droop control of AC microgrid. The DCC-based control methodology for AC microgrid and DC microgrid are further expanded to develop a DCC-based power management algorithm for hybrid AC/DC microgrid. The developed algorithm for hybrid microgrid controls the power flow through the interfacing converter (IC) between the AC and DC microgrids. This will facilitate the power sharing between the DGs according to their power ratings. Moreover, it enables the fixed scheduled power delivery at different operating conditions, while maintaining good voltage regulation and improved frequency profile. The second section provides a detailed explanation and step-by-step design and development of an AC/DC microgrid testbed. Controllers for the three-phase inverters are designed and tested on different generation units along with their corresponding inductor-capacitor-inductor (LCL) filters to eliminate the switching frequency harmonics. Electric power distribution line models are developed to form the microgrid network topology. Voltage and current sensors are placed in the proper

  4. Fast-ion losses induced by ACs and TAEs in the ASDEX Upgrade tokamak

    International Nuclear Information System (INIS)

    GarcIa-Munoz, M.; Hicks, N.; Classen, I.G.J.; Bilato, R.; Bobkov, V.; Brambilla, M.; Bruedgam, M.; Fahrbach, H.-U.; Igochine, V.; Maraschek, M.; Sassenberg, K.; Van Voornveld, R.; Jaemsae, S.

    2010-01-01

    The phase-space of convective and diffusive fast-ion losses induced by shear Alfven eigenmodes has been characterized in the ASDEX Upgrade tokamak. Time-resolved energy and pitch-angle measurements of fast-ion losses correlated in frequency and phase with toroidal Alfven eigenmodes (TAEs) and Alfven cascades (ACs) have allowed to identify both loss mechanisms. While single ACs and TAEs eject resonant fast-ions in a convective process, the overlapping of AC and TAE spatial structures leads to a large fast-ion diffusion and loss. The threshold for diffusive fast-ion losses depends on the ion energy (gyroradius). Diffusive fast-ion losses with gyroradius ∼70 mm have been observed with a single TAE for local radial displacements of the magnetic field lines larger than ∼2 mm. Multiple frequency chirping ACs cause an enhancement of the diffusive losses. The ACs and TAEs radial structures have been reconstructed by means of cross-correlation techniques between the fast-ion loss detector and the electron cyclotron emission radiometer.

  5. AC susceptibility of thin Pb films in intermediate and mixed state

    Energy Technology Data Exchange (ETDEWEB)

    Janu, Zdenek, E-mail: janu@fzu.cz [Institute of Physics of the AS CR, v.v.i., Na Slovance 2, CZ-182 21 Prague 8 (Czech Republic); Svindrych, Zdenek [Institute of Physics of the AS CR, v.v.i., Na Slovance 2, CZ-182 21 Prague 8 (Czech Republic); Trunecek, Otakar [Charles University in Prague, Faculty of Mathematics and Physics, Ke Karlovu 3, CZ-121 16 Prague 2 (Czech Republic); Kus, Peter; Plecenik, Andrej [Komenius University in Bratislava, Faculty of Mathematics, Physics, and Informatics, Mlynska dolina, 842 48 Bratislava 4 (Slovakia)

    2011-12-15

    Thickness dependent transition in AC susceptibility between intermediate and mixed state in type-I superconducting films. The temperature induced crossover between reversible and irreversible behavior was observed in the thicker film. The temperature dependence of the AC susceptibility in mixed state follows prediction of model based on Bean critical state. The temperature dependence of the harmonics of the complex AC susceptibility in the intermediate state is explained. Thin films of type I superconductors of a thickness comparable or less than a flux penetration length behave like type II superconductors in a mixed state. With decreasing film thickness normal domains carrying a magnetic flux get smaller with smaller number of flux quanta per domain and finally transform into single quantum flux lines, i.e. quantum vortices similar to those found in type II superconductors. We give an evidence of this behavior from the measurements of the nonlinear response of a total magnetic moment to an applied AC magnetic field, directly from the temperature dependence of an AC susceptibility.

  6. AC application of second generation HTS wire

    Science.gov (United States)

    Thieme, C. L. H.; Gagnon, K.; Voccio, J.; Aized, D.; Claassen, J.

    2008-02-01

    For the production of Second Generation (2G) YBCO High Temperature Superconductor wire American Superconductor uses a wide-strip MOD-YBCO/RABiTSTM process, a low-cost approach for commercial manufacturing. It can be engineered with a high degree of flexibility to manufacture practical 2G conductors with architectures and properties tailored for specific applications and operating conditions. For ac applications conductor and coil design can be geared towards low hysteretic losses. For applications which experience high frequency ac fields, the stabilizer needs to be adjusted for low eddy current losses. For these applications a stainless-steel laminate is used. An example is a Low Pass Filter Inductor which was developed and built in this work.

  7. Aging, Counterfeiting Configuration Control (AC3)

    Science.gov (United States)

    2010-01-31

    Systems Intergrated Into AC3 CABS - Common As-Built System PRISM - Process Re-inventing Integration Systems for Manufacturing PDM - Product Data...looks forward to deploying the completed tool at Raytheon in a true production environment, for as much as we like the challenge associated with...performance of DoD systems. DoD systems are particularly susceptible to intrusion of counterfeit parts, especially during surge and extended production

  8. The LHC AC Dipole system: an introduction

    CERN Document Server

    Serrano, J; CERN. Geneva. BE Department

    2010-01-01

    The LHC AC Dipole is an instrument to study properties of the LHC lattice by inducing large transverse displacements in the beam. These displacements are generated by exciting the beam with an oscillating magnetic field at a frequency close to the tune. This paper presents the system requirements and the technical solution chosen to meet them, based of high-power audio amplifiers and a resonant parallel RLC circuit.

  9. Modeling photovoltaic systems for AC appliances

    Directory of Open Access Journals (Sweden)

    Andreea Maria Neaca

    2009-10-01

    Full Text Available In this paper is described the development of a model which can simulate the performance of a photovoltaic (PV system under specific meteorological conditions and transforming the DC current into AC current. In this model, the accent stands on the design of a series charge regulator. It is treated also the benefit of creating a circuit, with different methods, that can test the maximum power point trackers (MPPT for different photovoltaic applications.

  10. Control of grid interactive AC microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Guerrero, Josep M.; Chen, Zhe

    2010-01-01

    Over the last decade, distributed energy resources (DER) technology has undergone a fast development. Increased penetration of DER units and wide spread use of renewable energy sources challenge the entire architecture of traditional power system. Microgrid, characterizing higher flexibility......, microgrid controls and power management strategies are presented. Future trends of microgrid are discussed pointing out how this concept can be a key to achieve a more intelligent and flexible AC grid....

  11. CTE Corrections for WFPC2 and ACS

    Science.gov (United States)

    Dolphin, Andrew

    2003-07-01

    The error budget for optical broadband photometry is dominated by three factors: CTE corrections, long-short anomaly corrections, and photometric zero points. Questions about the dependencies of the CTE have largely been resolved, and my CTE corrections have been included in the WFPC2 handbook and tutorial. What remains to be done is the determination of the "final" CTE correction at the end of the WFPC2 mission, which will increase the accuracy of photometry obtained in the final few cycles. The long-short anomaly is still the subject of much debate, as it remains unclear whethere or not this effect is real and, if so, what its size and nature is. Photometric zero points have likewise varied by over 0.05 magnitudes in the literature, and will likely remain unresolved until the long-short anomaly is addressed {given that most calibration exposures are short while most science exposures are long}. It is also becoming apparent that similar issues will affect the accuracy of ACS photometry, and consequently that an ACS CTE study analogous to my WFPC2 work would significantly improve the calibration of ACS. I therefore propose to use archival WFPC2 images of omega Cen and ACS images of 47 Tuc to continue my HST calibration work. I also propose to begin work on "next-generation" CTE corrections, in which corrections are applied to the images based on accurate charge-trapping models rather than to the reduced photometry. This technique will allow for more accurate CTE corrections in certain cases {such as a star above a bright star or on a variable background}, improved PSF-fitting photometry of faint stars, and image restoration for accurate analysis of extended objects.

  12. Non-Federal participation in AC Intertie: Final environmental impact statement

    International Nuclear Information System (INIS)

    1994-01-01

    Bonneville Power Administration (BPA) is considering action in two areas: (1) non-Federal access to the AC Intertie, and, (2) BPA Intertie marketing. BPA's preferred alternative for non-Federal access is the Capacity Ownership alternative combined with the Increased Assured Delivery -- Access for Non-Scheduling Utilities alternative; the preferred alternative for BPA Intertie marketing is the Federal Marketing and Joint Ventures alternative. BPA considered these two areas previously in its Intertie Development and Use EIS of April 1988. The EIS resulted in BPA decisions to participate in the construction of the Third AC Intertie, to allow non-Federal access to BPA's share of the Pacific Northwest-Pacific Southwest (PNW-PSW) Intertie (AC and DC lines) pursuant to a Long-Term Intertie Access Policy (LTIAP), and to pursue BPA's export marketing alternative. The decision on allowing direct financial non-Federal participation in the Third AC line was deferred to a later, separate process, examined here. Also, BPA's export marketing objectives must now be examined in view of changed operations of Columbia River hydro facilities for improved fish survival

  13. Non-Federal Participation in AC Intertie : Final Environmental Impact Statement. Volume 1: Environmental Analysis.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1994-01-01

    Bonneville Power Administration (BPA) is considering action in two areas: (1) non-Federal access to the AC Intertie, and, (2) BPA Intertie marketing. BPA`s preferred alternative for non-Federal access is the Capacity Ownership alternative combined with the Increased Assured Delivery -- Access for Non-Scheduling Utilities alternative; the preferred alternative for BPA Intertie marketing is the Federal Marketing and Joint Ventures alternative. BPA considered these two areas previously in its Intertie Development and Use EIS of April 1988. The EIS resulted in BPA decisions to participate in the construction of the Third AC Intertie, to allow non-Federal access to BPA`s share of the Pacific Northwest-Pacific Southwest (PNW-PSW) Intertie (AC and DC lines) pursuant to a Long-Term Intertie Access Policy (LTIAP), and to pursue BPA`s export marketing alternative. The decision on allowing direct financial non-Federal participation in the Third AC line was deferred to a later, separate process, examined here. Also, BPA`s export marketing objectives must now be examined in view of changed operations of Columbia River hydro facilities for improved fish survival.

  14. Direct amplitude detuning measurement with ac dipole

    Directory of Open Access Journals (Sweden)

    S. White

    2013-07-01

    Full Text Available In circular machines, nonlinear dynamics can impact parameters such as beam lifetime and could result in limitations on the performance reach of the accelerator. Assessing and understanding these effects in experiments is essential to confirm the accuracy of the magnetic model and improve the machine performance. A direct measurement of the machine nonlinearities can be obtained by characterizing the dependency of the tune as a function of the amplitude of oscillations (usually defined as amplitude detuning. The conventional technique is to excite the beam to large amplitudes with a single kick and derive the tune from turn-by-turn data acquired with beam position monitors. Although this provides a very precise tune measurement it has the significant disadvantage of being destructive. An alternative, nondestructive way of exciting large amplitude oscillations is to use an ac dipole. The perturbation Hamiltonian in the presence of an ac dipole excitation shows a distinct behavior compared to the free oscillations which should be correctly taken into account in the interpretation of experimental data. The use of an ac dipole for direct amplitude detuning measurement requires careful data processing allowing one to observe the natural tune of the machine; the feasibility of such a measurement is demonstrated using experimental data from the Large Hadron Collider. An experimental proof of the theoretical derivations based on measurements performed at injection energy is provided as well as an application of this technique at top energy using a large number of excitations on the same beam.

  15. Flame spread over inclined electrical wires with AC electric fields

    KAUST Repository

    Lim, Seung J.; Park, Sun H.; Park, Jeong; Fujita, Osamu; Keel, Sang I.; Chung, Suk-Ho

    2017-01-01

    Flame spread over polyethylene-insulated electrical wires was studied experimentally with applied alternating current (AC) by varying the inclination angle (θ), applied voltage (VAC), and frequency (fAC). For the baseline case with no electric field

  16. Interior point algorithm-based power flow optimisation of a combined AC and DC multi-terminal grid

    Directory of Open Access Journals (Sweden)

    Farhan Beg

    2015-01-01

    Full Text Available The high cost of power electronic equipment, lower reliability and poor power handling capacity of the semiconductor devices had stalled the deployment of systems based on DC (multi-terminal direct current system (MTDC networks. The introduction of voltage source converters (VSCs for transmission has renewed the interest in the development of large interconnected grids based on both alternate current (AC and DC transmission networks. Such a grid platform also realises the added advantage of integrating the renewable energy sources into the grid. Thus a grid based on DC MTDC network is a possible solution to improve energy security and check the increasing supply demand gap. An optimal power solution for combined AC and DC grids obtained by the solution of the interior point algorithm is proposed in this study. Multi-terminal HVDC grids lie at the heart of various suggested transmission capacity increases. A significant difference is observed when MTDC grids are solved for power flows in place of conventional AC grids. This study deals with the power flow problem of a combined MTDC and an AC grid. The AC side is modelled with the full power flow equations and the VSCs are modelled using a connecting line, two generators and an AC node. The VSC and the DC losses are also considered. The optimisation focuses on several different goals. Three different scenarios are presented in an arbitrary grid network with ten AC nodes and five converter stations.

  17. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

    2014-06-19

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  18. Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

    2013-10-15

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  19. Electrical and Biological Effects of Transmission Lines: A Review.

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jack M.

    1989-06-01

    This review describes the electrical properties of a-c and d-c transmission lines and the resulting effects on plants, animals, and people. Methods used by BPA to mitigate undesirable effects are also discussed. Although much of the information in this review pertains to high-voltage transmission lines, information on distribution lines and electrical appliances is included. The electrical properties discussed are electric and magnetic fields and corona: first for alternating-current (a-c) lines, then for direct current (d-c).

  20. Alpha decay 225 Ac → 221Fr

    International Nuclear Information System (INIS)

    Gromov, K. Ya.; Gorozhankin, V.M.; Malov, L.A.; Fominykh, V.I.; Tsupko-Sitnikov, V.V.; Chumin, V.G.; Jakushev, E.A.; Kudrya, S.A.; Sergienko, V.A.; Malikov, Sh.R.

    2004-01-01

    Full text: Considerable attention has been given to nuclei with A = 220 - 230 recently. In this region there occurs transition from the spherical to the deformed nuclear shape, which gives rise to some specific features in the nuclear structure. In particular, negative parity levels with low excitation energies have been found in even-even nuclei from this region [1, 2]. One of the nuclei allowing experimental investigation of the above properties is 221 Fr. The nuclide 221 Fr is from the region of isotopes which does not include stable nuclei and thus it cannot be studied in several-nucleon transfer reactions. In addition, the neutron excess in this nucleus makes it impossible to study the nucleus in reactions with heavy ions. Experimental information on the 221 Fr level structure can only be gained from investigation of the 225 Ac (T 1/2 = 10 days) alpha decay or the 221 Rn (T 1/2 = 25 min) beta decay. In the latter case the possibilities of the investigation are restricted by difficulties in making of 221 Rn sources. Therefore, most information on the structure and properties of 221 Fr is derived from investigation of the 225 Ac α -decay [3]. In-depth investigation of ( α - γ )- coincidences at the 225 Ac decay is carried out. Twenty-one new weak γ - rays are found; 18 γ-rays earlier ascribed to the 225 Ac decay are not confirmed. The quantitative analysis of the ( α - γ )- coincidences makes it possible to find the intensity of 221 Fr levels by the decay and multipolarities of five weak γ -transitions. The conversion electron spectrum is investigated in the range of 5 † 24 keV with a high (some 20 eV) energy resolution. A new M1 type 10.6-keV γ-transition is found. The proposed 225 Ac decay scheme includes 31 excited 221 Fr states. Parities are established for 16 of them. Possible spin values are proposed for 221 Fr levels. Properties of excited 221 Fr states are satisfactorily described by the quasiparticle-phonon nuclear model without the

  1. Molecular and functional characterization of CpACS27A gene reveals its involvement in monoecy instability and other associated traits in squash (Cucurbita pepo L.).

    Science.gov (United States)

    Martínez, Cecilia; Manzano, Susana; Megías, Zoraida; Barrera, Alejandro; Boualem, Adnane; Garrido, Dolores; Bendahmane, Abdelhafid; Jamilena, Manuel

    2014-06-01

    A number of Cucurbita pepo genotypes showing instable monoecy or partial andromonoecy, i.e. an incomplete conversion of female into bisexual flowers, have been detected. Given that in melon and cucumber andromonoecy is the result of reduction of ethylene production in female floral buds, caused by mutations in the ethylene biosynthesis genes CmACS7 and CsACS2; we have cloned and characterized two related C. pepo genes, CpACS27A and CpACS27B. The molecular structure of CpACS27A and its specific expression in the carpels of female flowers during earlier stages of flower development suggests that this gene is the Cucurbita ortholog of CmACS7 and CsACS2. CpACS27B is likely to be a paralogous pseudogene since it has not been found to be expressed in any of the analyzed tissues. CpACS27A was sequenced in Bolognese (Bog) and Vegetable Spaghetti (Veg), two monoecious inbred lines whose F2 was segregating for partial andromonoecy. The Bog allele of CpACS27A carried a missense mutation that resulted in a substitution of the conserved serine residue in position 176 by an alanine. Segregation analysis indicated that this mutant variant is necessary but not sufficient to confer the andromonoecious phenotype in squash. In concordance with its involvement in stamen arrest, a reduction in CpACS27A expression has been found in bisexual flower buds at earlier stages of development. This reduction in CpACS27A expression was concomitant with a downregulation of other ethylene biosynthesis and signaling genes during earlier and later stages of ovary development. The role of CpACS27A is discussed regarding the regulation of ethylene biosynthesis and signaling genes in the control of andromonoecy-associated traits, such as the delayed maturation of corolla and stigma as well as the parthenocarpic development of the fruit.

  2. Importance of Attenuation Correction (AC) for Small Animal PET Imaging

    DEFF Research Database (Denmark)

    El Ali, Henrik H.; Bodholdt, Rasmus Poul; Jørgensen, Jesper Tranekjær

    2012-01-01

    was performed. Methods: Ten NMRI nude mice with subcutaneous implantation of human breast cancer cells (MCF-7) were scanned consecutively in small animal PET and CT scanners (MicroPETTM Focus 120 and ImTek’s MicroCATTM II). CT-based AC, PET-based AC and uniform AC methods were compared. Results: The activity...

  3. An AMOLED AC-Biased Pixel Design Compensating the Threshold Voltage and I-R Drop

    Directory of Open Access Journals (Sweden)

    Ching-Lin Fan

    2011-01-01

    Full Text Available We propose a novel pixel design and an AC bias driving method for active-matrix organic light-emitting diode (AM-OLED displays using low-temperature polycrystalline silicon thin-film transistors (LTPS-TFTs. The proposed threshold voltage and I-R drop compensation circuit, which comprised three transistors and one capacitor, have been verified to supply uniform output current by simulation work using the Automatic Integrated Circuit Modeling Simulation Program with Integrated Circuit Emphasis (AIM-SPICE simulator. The simulated results demonstrate excellent properties such as low error rate of OLED anode voltage variation (<0.7% and low voltage drop of VDD power line. The proposed pixel circuit effectively enables threshold-voltage-deviation correction of driving TFT and compensates for the voltage drop of VDD power line using AC bias on OLED cathode.

  4. Sea-to-land transfer of technetium-99 through the use of contaminated seaweed as an agricultural soil conditioner

    International Nuclear Information System (INIS)

    Webster, Shona; Salt, Carol A.; Howard, Brenda J.

    2003-01-01

    The use of seaweed as an agricultural soil conditioner gives rise to a potential pathway for the transfer of Technetium-99 ( 99 Tc) from marine to terrestrial ecosystems and thence to man. However, to date there is little information on the extent of the release of 99 Tc from seaweed into soil and the mechanisms involved. This pot experiment has shown that 99 Tc is released fairly rapidly from Fucus vesiculosus into a sandy coastal soil. Despite low temperature conditions, 60% of the 99 Tc added with the seaweed had accumulated in the soil 15 weeks after addition. Concurrent CO 2 monitoring (used as a measure of microbial decomposition or catabolism) suggested that the initial 99 Tc release (up to 40% in the first 8 weeks) was due to leaching from the seaweed and that microbial decomposition was responsible for the release of the remaining 99 Tc in the latter phase (12-15 weeks)

  5. Power quality improvement by unified power quality conditioner based on CSC topology using synchronous reference frame theory.

    Science.gov (United States)

    Dharmalingam, Rajasekaran; Dash, Subhransu Sekhar; Senthilnathan, Karthikrajan; Mayilvaganan, Arun Bhaskar; Chinnamuthu, Subramani

    2014-01-01

    This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems.

  6. Cocomposting with and without Eisenia fetida for conversion of toxic paper mill sludge to a soil conditioner.

    Science.gov (United States)

    Kaur, Arvinder; Singh, Jaswinder; Vig, Adarsh Pal; Dhaliwal, S S; Rup, Pushpinder J

    2010-11-01

    Present study was envisaged for fast bioremediation of toxic paper mill sludge into a soil ameliorating agent. Although a rich source of organic carbon this sludge cannot be directly applied in fields and is recycled very slowly in landfills as it is deficient in other nutrients. Therefore it was mixed with cattle dung in various proportions and subjected to aerobic cocomposting (without worms) and vermicocomposting (with Eisenia fetida). It was observed that mixing cattle dung with the sludge improved physico-chemical characteristics (with transition metals in the permissible range for manures) of the products of both the processes and enhanced its acceptability for worms. Higher decline in organic carbon and higher content of nitrogen and phosphorous along with lower electrical conductivity and higher pH of the products of vermicomposting indicated that E. fetida helped in fast conversion of toxic paper mill sludge into a soil conditioner in 100days. Copyright 2010 Elsevier Ltd. All rights reserved.

  7. Power Quality Improvement by Unified Power Quality Conditioner Based on CSC Topology Using Synchronous Reference Frame Theory

    Directory of Open Access Journals (Sweden)

    Rajasekaran Dharmalingam

    2014-01-01

    Full Text Available This paper deals with the performance of unified power quality conditioner (UPQC based on current source converter (CSC topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems.

  8. Power Quality Improvement by Unified Power Quality Conditioner Based on CSC Topology Using Synchronous Reference Frame Theory

    Science.gov (United States)

    Dharmalingam, Rajasekaran; Dash, Subhransu Sekhar; Senthilnathan, Karthikrajan; Mayilvaganan, Arun Bhaskar; Chinnamuthu, Subramani

    2014-01-01

    This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems. PMID:25013854

  9. Radio decontamination of hair conditioner for capillary ammniotherapy; Radiodescontaminacion del acondicionador del cabello destinado a la amnioterapia capilar

    Energy Technology Data Exchange (ETDEWEB)

    Romay, Z; Otero, I; Chavez, A [Centro de Estudios Aplicados al Desarrollo Nuclear (CEADEN), La Habana (Cuba); Torriente, I [Centro de Histoterapia Placentaria, La Habana (Cuba)

    1997-12-31

    The Hair conditioner, which belongs to the group of cosmetic products Dr Miyares Cao, was artificially contaminated, kept at different values of temperature (-20 {sup oC}, 0{sup oC} and +20{sup oC}) and irradiated to different doses (6, 10, 12, 15, 20, 25 and 30 kGy) and 25 {sup oC} for studying the effect of gamma radiation on it and the possibility of use of this technology for its decontamination. The radiobiological parameters of the contaminator and the quality of irradiated products were determined. Was conclude that the product maintain its organolepthics characteristics and others quality parameters after irradiated to 20 kGy and +20{sup oC} of temperature before irradiation. Finally, the decontamination of studied product was obtained by means its irradiation to 16.2 kGy.

  10. Development of a hardware-based AC microgrid for AC stability assessment

    Science.gov (United States)

    Swanson, Robert R.

    As more power electronic-based devices enable the development of high-bandwidth AC microgrids, the topic of microgrid power distribution stability has become of increased interest. Recently, researchers have proposed a relatively straightforward method to assess the stability of AC systems based upon the time-constants of sources, the net bus capacitance, and the rate limits of sources. In this research, a focus has been to develop a hardware test system to evaluate AC system stability. As a first step, a time domain model of a two converter microgrid was established in which a three phase inverter acts as a power source and an active rectifier serves as an adjustable constant power AC load. The constant power load can be utilized to create rapid power flow transients to the generating system. As a second step, the inverter and active rectifier were designed using a Smart Power Module IGBT for switching and an embedded microcontroller as a processor for algorithm implementation. The inverter and active rectifier were designed to operate simultaneously using a synchronization signal to ensure each respective local controller operates in a common reference frame. Finally, the physical system was created and initial testing performed to validate the hardware functionality as a variable amplitude and variable frequency AC system.

  11. Pixel-based CTE Correction of ACS/WFC: Modifications To The ACS Calibration Pipeline (CALACS)

    Science.gov (United States)

    Smith, Linda J.; Anderson, J.; Armstrong, A.; Avila, R.; Bedin, L.; Chiaberge, M.; Davis, M.; Ferguson, B.; Fruchter, A.; Golimowski, D.; Grogin, N.; Hack, W.; Lim, P. L.; Lucas, R.; Maybhate, A.; McMaster, M.; Ogaz, S.; Suchkov, A.; Ubeda, L.

    2012-01-01

    The Advanced Camera for Surveys (ACS) was installed on the Hubble Space Telescope (HST) nearly ten years ago. Over the last decade, continuous exposure to the harsh radiation environment has degraded the charge transfer efficiency (CTE) of the CCDs. The worsening CTE impacts the science that can be obtained by altering the photometric, astrometric and morphological characteristics of sources, particularly those farthest from the readout amplifiers. To ameliorate these effects, Anderson & Bedin (2010, PASP, 122, 1035) developed a pixel-based empirical approach to correcting ACS data by characterizing the CTE profiles of trails behind warm pixels in dark exposures. The success of this technique means that it is now possible to correct full-frame ACS/WFC images for CTE degradation in the standard data calibration and reduction pipeline CALACS. Over the past year, the ACS team at STScI has developed, refined and tested the new software. The details of this work are described in separate posters. The new code is more effective at low flux levels (repair ACS electronics) and pixel-based CTE correction. In addition to the standard cosmic ray corrected, flat-fielded and drizzled data products (crj, flt and drz files) there are three new equivalent files (crc, flc and drc) which contain the CTE-corrected data products. The user community will be able to choose whether to use the standard or CTE-corrected products.

  12. Experimental investigation of HFC407C/HC290/HC600a mixture in a window air conditioner

    International Nuclear Information System (INIS)

    Jabaraj, D.B.; Avinash, P.; Lal, D. Mohan; Renganarayan, S.

    2006-01-01

    HCFC22, one of the widely used refrigerants in window air conditioners must be phased out soon as per the Montreal protocol. Presently, HFC407C is considered as a potential drop in substitute for HCFC22, but retrofitting HCFC22 systems with HFC407C with polyol ester oil (POE) is a major issue as HFC407C is immiscible with mineral oil. The miscibility issue of HFC407C with mineral oil was overcome with the addition of a HC blend to it. The above technoeconomic feasibility issues to retrofit the existing HCFC22 systems with an ozone friendly refrigerant and retain the energy efficiency of the system are challenges in the air conditioning sector. In this present work, an experimental analysis has been conducted in a window air conditioner retrofitted with eco-friendly refrigerant mixtures of HFC407C/HC290/HC600a without changing the mineral oil. Its performance, as well as energy consumption, was compared with the conventional one. It is observed that the mixtures demand lengthening of the condenser in order to maintain the discharge pressure within acceptable limits. This also resulted in better heat transfer at the condenser. Therefore, in this study, the condenser tube length was increased by 19% to suit the mixtures as compared to HCFC22. Compared to HCFC22, the refrigeration capacity of the new mixture was 9.54-12.76% higher than that of HCFC22, while the actual COP was found to be 11.91-13.24% higher than that of HCFC22. The overall performance has proved that the HFC407C/HC blend refrigerant mixture could be an eco-friendly substitute to phase out HCFC22

  13. Kalanchosides A-C, new cytotoxic bufadienolides from the aerial parts of Kalanchoe gracilis.

    Science.gov (United States)

    Wu, Pei-Lin; Hsu, Yu-Lin; Wu, Tian-Shung; Bastow, K F; Lee, Kuo-Hsiung

    2006-11-09

    [Structure: see text] Three new compounds, kalanchosides A-C (1-3), as well as five known compounds, were isolated from the aerial parts of Kalanchoe gracilis. The compound structures were determined by spectroscopic methods. All eight isolated compounds showed significant cytotoxic activity against a panel of human tumor cell lines, with potency reaching the nanomolar range. However, only bryophyllin B (8) inhibited HIV replication in H9 lymphocyte cells.

  14. The role of baculovirus apoptotic suppressors in AcMNPV-mediated translation arrest in Ld652Y cells

    International Nuclear Information System (INIS)

    Thiem, Suzanne M.; Chejanovsky, Nor

    2004-01-01

    Infecting the insect cell line IPLB-Ld652Y with the baculovirus Autographa californica multinucleocapsid nucleopolyhedrovirus (AcMNPV) results in global translation arrest, which correlates with the presence of the AcMNPV apoptotic suppressor, p35. In this study, we investigated the role of apoptotic suppression on AcMNPV-induced translation arrest. Infecting cells with AcMNPV bearing nonfunctional mutant p35 did not result in global translation arrest. In contrast, global translation arrest was observed in cells infected with AcMNPV in which p35 was replaced with Opiap, Cpiap, or p49, baculovirus apoptotic suppressors that block apoptosis by different mechanisms than p35. These results indicated that suppressing apoptosis triggered translation arrest in AcMNPV-infected Ld652Y cells. Experiments using the DNA synthesis inhibitor aphidicolin and temperature shift experiments, using the AcMNPV replication mutants ts8 and ts8Δp35, indicated that translation arrest initiated during the early phase of infection, but events during the late phase were required for global translation arrest. Peptide caspase inhibitors could not substitute for baculovirus apoptotic suppressors to induce translation arrest in Ld652Y cells infected with a p35-null virus. However, if the p35-null-AcMNPV also carried hrf-1, a novel baculovirus host range gene, progeny virus was produced and treatment with peptide caspase inhibitors enhanced translation of a late viral gene transcript. Together, these results indicate that translation arrest in AcMNPV-infected Ld652Y cells is due to the anti-apoptotic function of p35, but suggests that rather than simply preventing caspase activation, its activity enhances signaling to a separate translation arrest pathway, possibly by stimulating the late stages of the baculovirus infection cycle

  15. MATHEMATICAL MODELING OF AC ELECTRIC POINT MOTOR

    Directory of Open Access Journals (Sweden)

    S. YU. Buryak

    2014-03-01

    Full Text Available Purpose. In order to ensure reliability, security, and the most important the continuity of the transportation process, it is necessary to develop, implement, and then improve the automated methods of diagnostic mechanisms, devices and rail transport systems. Only systems that operate in real time mode and transmit data on the instantaneous state of the control objects can timely detect any faults and thus provide additional time for their correction by railway employees. Turnouts are one of the most important and responsible components, and therefore require the development and implementation of such diagnostics system.Methodology. Achieving the goal of monitoring and control of railway automation objects in real time is possible only with the use of an automated process of the objects state diagnosing. For this we need to know the diagnostic features of a control object, which determine its state at any given time. The most rational way of remote diagnostics is the shape and current spectrum analysis that flows in the power circuits of railway automatics. Turnouts include electric motors, which are powered by electric circuits, and the shape of the current curve depends on both the condition of the electric motor, and the conditions of the turnout maintenance. Findings. For the research and analysis of AC electric point motor it was developed its mathematical model. The calculation of parameters and interdependencies between the main factors affecting the operation of the asynchronous machine was conducted. The results of the model operation in the form of time dependences of the waveform curves of current on the load on engine shaft were obtained. Originality. During simulation the model of AC electric point motor, which satisfies the conditions of adequacy was built. Practical value. On the basis of the constructed model we can study the AC motor in various mode of operation, record and analyze current curve, as a response to various changes

  16. AC susceptibility enhancement studies in magnetic systems

    International Nuclear Information System (INIS)

    Mukherjee, S.; Ranganathan, R.; Chakravarti, A.; Sil, S.

    2001-01-01

    Enhancement of AC susceptibility has been observed for typical ferromagnets (Gd), reentrant spin glasses like (Fe 1.5 Mn 1.5 Si) and canted spin systems (Ce(Fe 0.96 Al 0.04 ) 2 ). The data have been interpreted with the help of a simulation model based on dry friction-like pinning of domain walls for systems having ferromagnetic domain structures. A strong pinning mechanism appears in the reentrant spin glass like and canted spin systems at low temperatures in addition to the intrinsic one in the ferromagnetic phase. The temperature variation of the pinning potential has been given qualitatively for the reentrant spin glass like systems

  17. Protection of AC and DC Microgrids

    DEFF Research Database (Denmark)

    Beheshtaein, Siavash; Savaghebi, Mehdi; Quintero, Juan Carlos Vasquez

    2015-01-01

    and DC microgrids, and then investigates the existing and promising solutions for the corresponding challenges. To the authors’ knowledge, three parts of smart grids are required to be developed to facilitate implementation of protection scheme in microgrids. The main requirements and open issues......In future, distributed energy resources (RESs) will be utilized at consumption points. As a consequence, power flow and fault current would be bidirectional and topologydependent; and hence the conventional protection strategies would be inefficient. This paper categorizes the main challenges in AC...

  18. Flexible AC transmission systems modelling and control

    CERN Document Server

    Zhang, Xiao-Ping; Pal, Bikash

    2012-01-01

    The extended and revised second edition of this successful monograph presents advanced modeling, analysis and control techniques of Flexible AC Transmission Systems (FACTS). The book covers comprehensively a range of power-system control problems: from steady-state voltage and power flow control, to voltage and reactive power control, to voltage stability control, to small signal stability control using FACTS controllers. In the six years since the first edition of the book has been published research on the FACTS has continued to flourish while renewable energy has developed into a mature and

  19. DC injection into low voltage AC networks

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This report summarises the results of a study investigating the impact of levels of injected DC current injections on a low voltage AC distribution network systems in order to recommend acceptable limits of DC from microgeneration. Relevant literature is reviewed, and the impact of DC levels in distribution transformers, transformer modelling, and instrumental transformers are discussed. The impact of DC in residual current devices (RCD) and in domestic electricity watt hour meters is examined along with DC enhanced corrosion, corrosion failure, and the measurement of DC current injection. Sources of DC injection outlined include DC from computer power supplies, network faults, geomagnetic phenomena, lighting circuits/dimmers, and embedded generators.

  20. Three-Level AC-DC-AC Z-Source Converter Using Reduced Passive Component Count

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Gao, Feng; Tan, Pee-Chin

    2009-01-01

    This paper presents a three-level ac-dc-ac Z-source converter with output voltage buck-boost capability. The converter is implemented by connecting a low-cost front-end diode rectifier to a neutral-point-clamped inverter through a single X-shaped LC impedance network. The inverter is controlled...... to switch with a three-level output voltage, where the middle neutral potential is uniquely tapped from the star-point of a wye-connected capacitive filter placed before the front-end diode rectifier for input current filtering. Through careful control, the resulting converter can produce the correct volt...

  1. Transcranial Alternating Current Stimulation (tACS Mechanisms and Protocols

    Directory of Open Access Journals (Sweden)

    Amir V. Tavakoli

    2017-09-01

    Full Text Available Perception, cognition and consciousness can be modulated as a function of oscillating neural activity, while ongoing neuronal dynamics are influenced by synaptic activity and membrane potential. Consequently, transcranial alternating current stimulation (tACS may be used for neurological intervention. The advantageous features of tACS include the biphasic and sinusoidal tACS currents, the ability to entrain large neuronal populations, and subtle control over somatic effects. Through neuromodulation of phasic, neural activity, tACS is a powerful tool to investigate the neural correlates of cognition. The rapid development in this area requires clarity about best practices. Here we briefly introduce tACS and review the most compelling findings in the literature to provide a starting point for using tACS. We suggest that tACS protocols be based on functional brain mechanisms and appropriate control experiments, including active sham and condition blinding.

  2. UHV A.C. transmission: Technology and prospects

    International Nuclear Information System (INIS)

    Cauzillo, B.A.; Manzoni, G.; Nicolini, P.

    1992-04-01

    At the beginning of the 70's, UHV transmission was regarded as imminent in many countries in view of the expected concentration of generating units (possibly of the nuclear type and grouped together in a few large plants, each of several GW), and research projects were therefore launched in the U.S.A., Canada, Italy, Japan, USSR, etc. Nowadays, the expected introduction of UHV transmission seems remote due to the slowdown in electricity growth and to the tendency towards distributed generation. Nevertheless, there are exceptions: the 1,200 kV 2,400 km-long transmission system in operation in Siberia-Kazahkstan-Urals, and the 1,100 kV 200 km double-circuit line under construction in Japan (which will, however, be operated at 500 kV up to the end of the century). In addition, in Italy, the research programme of a 1000 kV project has now been completed and a 1,050 kV pilot plant is under construction in Tuscany, consisting of a short 1,050kV line and a 420/1,050 kV 1,200 MVA substation. The technology of UHV AC transmission has therefore been proved effective and may represent an available option for the power systems of the next century. From the power system planning point-of-view, UHV's favourable characteristics lie in the possibility of transmitting large amount of power, of the order of 5 GW per circuit, with lower costs, reduced losses, and less land occupation than in the case of EHV lines

  3. Bifurcation theory of ac electric arcing

    International Nuclear Information System (INIS)

    Christen, Thomas; Peinke, Emanuel

    2012-01-01

    The performance of alternating current (ac) electric arcing devices is related to arc extinction or its re-ignition at zero crossings of the current (so-called ‘current zero’, CZ). Theoretical investigations thus usually focus on the transient behaviour of arcs near CZ, e.g. by solving the modelling differential equations in the vicinity of CZ. This paper proposes as an alternative approach to investigate global mathematical properties of the underlying periodically driven dynamic system describing the electric circuit containing the arcing device. For instance, the uniqueness of the trivial solution associated with the insulating state indicates the extinction of any arc. The existence of non-trivial attractors (typically a time-periodic state) points to a re-ignition of certain arcs. The performance regions of arcing devices, such as circuit breakers and arc torches, can thus be identified with the regions of absence and existence, respectively, of non-trivial attractors. Most important for applications, the boundary of a performance region in the model parameter space is then associated with the bifurcation of the non-trivial attractors. The concept is illustrated for simple black-box arc models, such as the Mayr and the Cassie model, by calculating for various cases the performance boundaries associated with the bifurcation of ac arcs. (paper)

  4. Measuring Gravitational Flexion in ACS Clusters

    Science.gov (United States)

    Goldberg, David

    2005-07-01

    We propose measurement of the gravitational "Flexion" signal in ACS cluster images. The flexion, or "arciness" of a lensed background galaxy arises from variations in the lensing field. As a result, it is extremely sensitive to small scale perturbations in the field, and thus, to substructure in clusters. Moreover, because flexion represents gravitationally induced asymmetries in the lensed image, it is completely separable from traditional measurements of shear, which focus on the induced ellipticity of the image, and thus, the two signals may be extracted simultaneously. Since typical galaxies are roughly symmetric upon 180 degree rotation, even a small induced flexion can potentially produce a noticeable effect {Goldberg & Bacon, 2005}. We propose the measurement of substructure within approximately 4 clusters with high-quality ACS data, and will further apply a test of a new tomographic technique whereby comparisons of lensed arcs at different redshifts may be used to estimate the background cosmology, and thus place constraints on the equation of state of dark energy.

  5. Deletion of the AcMNPV core gene ac109 results in budded virions that are non-infectious

    International Nuclear Information System (INIS)

    Fang Minggang; Nie, Yingchao; Theilmann, David A.

    2009-01-01

    Autographa californica multiple nucleopolyhedrovirus (AcMNPV) ac109 is a core gene and its function in the virus life cycle is unknown. To determine its role in the baculovirus life cycle, we used the AcMNPV bacmid system to generate an ac109 deletion virus (vAc 109KO ). Fluorescence and light microscopy showed that transfection of vAc 109KO results in a single-cell infection phenotype. Viral DNA replication is unaffected and the development of occlusion bodies in vAc 109KO -transfected cells evidenced progression to the very late phases of viral infection. Western blot and confocal immunofluorescence analysis showed that AC109 is expressed in the cytoplasm and nucleus throughout infection. In addition, AC109 is a structural protein as it was detected in both budded virus (BV) and occlusion derived virus in both the envelope and nucleocapsid fractions. Titration assays by qPCR and TCID 50 showed that vAc 109KO produced BV but the virions are non-infectious. The vAc 109KO BV were indistinguishable from the BV of repaired and wild type control viruses as determined by negative staining and electron microscopy.

  6. Modeling and reliability analysis of three phase z-source AC-AC converter

    Directory of Open Access Journals (Sweden)

    Prasad Hanuman

    2017-12-01

    Full Text Available This paper presents the small signal modeling using the state space averaging technique and reliability analysis of a three-phase z-source ac-ac converter. By controlling the shoot-through duty ratio, it can operate in buck-boost mode and maintain desired output voltage during voltage sag and surge condition. It has faster dynamic response and higher efficiency as compared to the traditional voltage regulator. Small signal analysis derives different control transfer functions and this leads to design a suitable controller for a closed loop system during supply voltage variation. The closed loop system of the converter with a PID controller eliminates the transients in output voltage and provides steady state regulated output. The proposed model designed in the RT-LAB and executed in a field programming gate array (FPGA-based real-time digital simulator at a fixedtime step of 10 μs and a constant switching frequency of 10 kHz. The simulator was developed using very high speed integrated circuit hardware description language (VHDL, making it versatile and moveable. Hardware-in-the-loop (HIL simulation results are presented to justify the MATLAB simulation results during supply voltage variation of the three phase z-source ac-ac converter. The reliability analysis has been applied to the converter to find out the failure rate of its different components.

  7. Dynamic characteristics of corona discharge generated under rainfall condition on AC charged conductors

    Science.gov (United States)

    Xu, Pengfei; Zhang, Bo; Wang, Zezhong; Chen, Shuiming; He, Jinliang

    2017-12-01

    By synchronous measurement of corona current and the water droplet deformation process on a conductor surface, different types of corona discharge are visualized when AC voltage is applied on a line-ground electrode system. The corona characteristics are closely related to the applied voltage and water supply rate. With the increase of AC voltage, the positive Taylor cone discharge firstly appears and then disappears, replaced by the dripping and crashing discharge. Furthermore, the number of pulses in each pulse train increases with the increase of applied voltage. The mechanism of the transfer from the positive Taylor cone discharge to the dripping and crashing discharge is found to be related to the oscillation process of the water droplet. The water supply rate also has a great influence on the characteristics of corona currents. The number of positive pulse trains increases linearly when the water supply rate gets larger, leading to a higher audible noise and radio interference level from the AC corona, which is quite different from that of the DC corona. The difference between the AC and DC coronas under rainfall conditions is analyzed finally.

  8. Temperature control of the four-zone split inverter air conditioners using LMI expression based on LQR for mixed H2/H∞

    International Nuclear Information System (INIS)

    Yang, YauBin; Wu, Min-Der; Chang, Yu-Choung

    2014-01-01

    Highlights: • The optimal control gains were obtained from the linear matrix inequalities with mixed H 2 and H ∞ control algorithm. • The proposed method guaranteed convergence, stability, and provided a way for disturbance rejection and energy savings. • The coupling effects occurred among the compressor speed, opening degrees, evaporator temperatures and superheats. • The system identification and thermal dynamics equations could obtain the inner and outer loop transfer functions. • All simulations in this paper were in discrete time domain. - Abstract: Air conditioners in either commercial or residential buildings consume substantial electricity. Enhancing the air conditioner efficiency by using a new control scheme is critical. In four-zone multi-evaporator air conditioner systems, coupling effects occur among the compressor speed, the degree of opening of the four electronic expansion valves, the temperatures of the four evaporators, and the four superheats. The system identification and thermodynamic equations could be used to obtain the inner and outer loop transfer functions between the air conditioner and its environment. A variable structure (switching) for the proportional integral anti-windup method could circumvent the saturation phenomenon generated from the integral controller. The optimal control gains were obtained from the linear matrix inequalities (LMI) based on a linear quadratic regulator (LQR) with a mixed H 2 and H ∞ control algorithm. In a simulated example, this efficient method, through those feedback gains, guaranteed convergence and stability. In addition, the results indicated that the proposed LMI using a mixed H 2 and H ∞ control method is also an alternative way for disturbance rejection and energy savings in buildings

  9. The use of heteroduplex analysis of polymerase chain reaction products to support the possible transmission of Legionella pneumophila from a malfunctioning automobile air conditioner.

    Science.gov (United States)

    Pinar, Ahmet; Ramirez, Julio A; Schindler, Laura L; Miller, Richard D; Summersgill, James T

    2002-03-01

    Air conditioner condensates have not been previously associated with cases of Legionnaires' disease. We report the possible transmission of Legionella pneumophila serogroup 1 from a malfunctioning automobile air conditioning system's leaking water onto the floorboard of a car driven for a long distance by the patient. Heteroduplex analysis of polymerase chain reaction products was used to help establish an epidemiologic link between the water specimen and the patient.

  10. Draft Genome Sequence of a Novel Chitinophaga sp. Strain, MD30, Isolated from a Biofilm in an Air Conditioner Condensate Pipe.

    Science.gov (United States)

    Wan, Xuehua; Darris, Maxwell; Hou, Shaobin; Donachie, Stuart P

    2017-10-19

    Most of the 24 known Chitinophaga species were originally isolated from soils. We report the draft genome sequence of a putatively novel Chitinophaga sp. from a biofilm in an air conditioner condensate pipe. The genome comprises 7,661,303 bp in one scaffold, 5,694 predicted protein-coding sequences, and a G+C content of 47.6%. Copyright © 2017 Wan et al.

  11. Alternative Refrigerant Evaluation for High-Ambient Temperature Environments: R-22 and R-410A Alternatives for Mini-Split Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Munk, Jeffrey D [ORNL; Shrestha, Som S [ORNL; Linkous, Randall Lee [ORNL; Goetzler, William [Navigant Consulting Inc.; Guernsey, Matt [Navigant Consulting Inc.; Kassuga, Theo [Navigant Consulting Inc.

    2015-08-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient Temperature Testing Program for Low-GWP Refrigerants aims to develop an understanding of the performance of low-Global Warming Potential (low-GWP) alternatives to Hydrochlorofluorocarbon (HCFC) and Hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high ambient temperature conditions. This interim working paper describes the parties involved, the alternative refrigerants selection process, the test procedures, and the preliminary results.

  12. Alternative Refrigerant Evaluation for High-Ambient-Temperature Environments: R-22 and R-410A Alternatives for Mini-Split Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goetzler, William [Navigant Consulting Inc., Burlington, MA (United States); Guernsey, Matt [Navigant Consulting Inc., Burlington, MA (United States); Kassuga, Theo [Navigant Consulting Inc., Burlington, MA (United States)

    2015-10-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for low– global warming potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerant selection process, the test procedures, and the final results.

  13. AC losses in high Tc superconductors

    International Nuclear Information System (INIS)

    Campbell, A.M.

    1998-01-01

    Full text: Although in principle the AC losses in high Tc superconductors can be calculated from the critical current density, a number of complications make this difficult. The Jc is very field dependent, there are intergranular and intragranular critical currents, the material is anisotropic and there is usually a large demagnetising factor. Care must be taken in interpreting electrical measurements since the voltage depends on the position of the contacts. In spite of these complications the simple theory of Norris has proved surprisingly successful and arguments will be presented as to why this is the case. Results on a range of tapes will be compared with theory and numerical methods for predicting losses discussed. Finally a theory for coupling losses will be given for a composite conductor with high resistance barriers round the filaments

  14. Transcranial alternating current stimulation (tACS

    Directory of Open Access Journals (Sweden)

    Andrea eAntal

    2013-06-01

    Full Text Available Transcranial alternating current stimulation (tACS seems likely to open a new era of the field of noninvasive electrical stimulation of the human brain by directly interfering with cortical rhythms. It is expected to synchronize (by one single resonance frequency or desynchronize (e.g. by the application of several frequencies cortical oscillations. If applied long enough it may cause neuroplastic effects. In the theta range it may improve cognition when applied in phase. Alpha rhythms could improve motor performance, whereas beta intrusion may deteriorate them. TACS with both alpha and beta frequencies has a high likelihood to induce retinal phosphenes. Gamma intrusion can possibly interfere with attention. Stimulation in the ripple range induces intensity dependent inhibition or excitation in the motor cortex most likely by entrainment of neuronal networks, whereas stimulation in the low kHz range induces excitation by neuronal membrane interference. TACS in the 200 kHz range may have a potential in oncology.

  15. Ac loss measurement of SSC dipole magnets

    International Nuclear Information System (INIS)

    Delchamps, S.; Hanft, R.; Jaffery, T.; Kinney, W.; Koska, W.; Lamm, M.J.; Mazur, P.O.; Orris, D.; Ozelis, J.P.; Strait, J.; Wake, M.

    1992-09-01

    AC losses in full length and 1.5 m model SSC collider dipoles were successfully measured by the direct observation of energy flow into and out of magnets during a ramp cycle. The measurement was performed by using two double-integrating type digital volt meters (DVM's) for current and voltage measurement. Measurements were performed for six is m long ASST magnets and five 1.5 m long model magnets, inducting one 40 mm diameter magnet. There were large variations in the eddy current losses. Since these magnets use conductors with slight deviations in their internal structures and processing of the copper surface depending on the manufacturer, it is likely that there are differences in the contact resistance between strands. Correlation between the ramp rate dependence of the,quench current and the eddy current loss was evident

  16. Increased prevalence of IgG-induced sensitization and hypersensitivity pneumonitis (humidifier lung) in nonsmokers exposed to aerosols of a contaminated air conditioner.

    Science.gov (United States)

    Baur, X; Richter, G; Pethran, A; Czuppon, A B; Schwaiblmair, M

    1992-01-01

    Specific IgG antibodies against antigens of a contaminated air conditioner were estimated in serum of 134 workers of a printing company. Altogether 64% of the workers investigated revealed significantly elevated levels (> 3 U/ml) of IgG antibodies specific to these antigens as compared to a nonexposed control group. The occurrence of IgG antibodies for microbial extracts were 25% for Fusarium, 23% for Penicillium notatum, 13% for Alternaria tenuis, 12% for Aureobasidium pullulans, 9% for Sphaeropsidales species, 3% for Micropolyspora faeni, 2% for Aspergillus fumigatus and 2% for Thermoactionomyces vulgaris. Out of the 86 workers with elevated IgG antibodies for air conditioner antigens, 59 were nonsmokers. Considering a cut-off level of 10 U/ml IgG for high values, the proportion of smokers to nonsmokers becomes even more pronounced (6 to 36 respectively, binominal test p air conditioners are the best choice as antigen source for the diagnosis of humidifier lung in exposed workers. Nonsmokers are shown to have a high risk for immunological sensitization.

  17. Study on load levelling by means of the control of air conditioner operation; Kuchoki kado seigyo ni yoru fuka heijunka ni kansuru ichikosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, H. [Hiroshima University, Hiroshima (Japan); Sadakuni, S. [Japan Broadcasting Corp., Tokyo (Japan)

    1995-04-20

    The recent drastic increase in the number of air conditioners has caused sharp and narrow peaks in summer seasons due to the inherent temperature sensitive characteristics. The authors proposed to reduce the peak power demand by controlling air conditioner operations, verifying its effectiveness on peak demand clipping. However, the former study has shortcomings in that any qualitative treatment of room temperatures or pleasant feeling was not attempted and it did not provide a way of assessing peak demand clipping in a power system as a whole. In this paper, we shall first propose a new control method that can compromise pleasant feeling and reduction in power demand. Although air conditioners are used to pursue `pleasant feeling`, this contradicts to reduce power consumption and further more the concept of `pleasant feeling` is very vague. Hence, `Weber-Fechner`s law` is utilized to quantify the pleasant feeling which is treated as fuzzy quantity. Fuzzy co-ordination method is used to compromise power demand curtailment and pleasantness. In the second part of this paper, we shall propose an approach of assessing the amount of peak load clipping when the newly proposed control strategy is adopted in a real size power system: A decrease in the required generation capacity is estimated provided that the Loss of Load Probability (LOLP) is maintained at the same level before and after the application of the new control strategy. The reduction can be regarded as a dividend of load management. 5 refs., 9 figs., 5 tabs.

  18. High Line

    DEFF Research Database (Denmark)

    Kiib, Hans

    2015-01-01

    At just over 10 meters above street level, the High Line extends three kilometers through three districts of Southwestern Manhattan in New York. It consists of simple steel construction, and previously served as an elevated rail line connection between Penn Station on 34th Street and the many....... The High Line project has been carried out as part of an open conversion strategy. The result is a remarkable urban architectural project, which works as a catalyst for the urban development of Western Manhattan. The greater project includes the restoration and reuse of many old industrial buildings...

  19. AC conductivity and dielectric behavior of bulk Furfurylidenemalononitrile

    Science.gov (United States)

    El-Nahass, M. M.; Ali, H. A. M.

    2012-06-01

    AC conductivity and dielectric behavior for bulk Furfurylidenemalononitrile have been studied over a temperature range (293-333 K) and frequency range (50-5×106 Hz). The frequency dependence of ac conductivity, σac, has been investigated by the universal power law, σac(ω)=Aωs. The variation of the frequency exponent (s) with temperature was analyzed in terms of different conduction mechanisms, and it was found that the correlated barrier hopping (CBH) model is the predominant conduction mechanism. The temperature dependence of σac(ω) showed a linear increase with the increase in temperature at different frequencies. The ac activation energy was determined at different frequencies. Dielectric data were analyzed using complex permittivity and complex electric modulus for bulk Furfurylidenemalononitrile at various temperatures.

  20. Transition towards DC micro grids: From an AC to a hybrid AC and DC energy infrastructure

    Directory of Open Access Journals (Sweden)

    Evi Ploumpidou

    2017-12-01

    Full Text Available Our electricity is predominantly powered by alternating current (AC, ever since the War of Currents ended in the favor of Nicola Tesla at the end of the 19th century. However, lots of the appliances we use, such as electronics and lights with light-emitting diode (LED technology, work internally on direct current (DC and it is projected that the number of these appliances will increase in the near future. Another contributor to the increase in DC consumption is the ongoing electrification of mobility (Electric Vehicles (EVs. At the same time, photovoltaics (PV generate DC voltages, while the most common storage technologies also use DC. In order to integrate all these appliances and technologies to the existing AC grid, there is a need for converters which introduce power losses. By distributing DC power to DC devices instead of converting it to AC first, it is possible to avoid substantial energy losses that occur every time electricity is converted. This situation initiated the concept for the implementation of the DC-Flexhouse project. A prototype DC installation will be developed and tested in one of the buildings of the developing living lab area called the District of Tomorrow (De Wijk van Morgen which is located in Heerlen, the Netherlands. A neighborhood cooperative (Vrieheide cooperatie is also part of the consortium in order to address the aspect of social acceptance. Although DC seems to be a promising solution for a more sustainable energy system, the business case is still debatable due to both technology- and market-related challenges. The current energy infrastructure is predominantly based on AC, manufacturers produce devices based on AC standards and people are using many AC products across a long life span. This Smart Energy Buildings & Cities (SEB&C PDEng project is a contribution to the DC-Flexhouse project. The aim is to analyze the challenges in the transition to DC micro grids, assess the market potential of DC

  1. Low field critical currents and ac losses of thin film niobium--tin superconductors

    International Nuclear Information System (INIS)

    Howard, R.E.

    1977-01-01

    The results of a study of the low field critical current and ac loss properties of niobium-tin thin films and layered composites fabricated by electron-beam coevaporation are presented. Particular emphasis is placed upon determining the suitability of this material for use as a conductor in a superconducting power transmission line. Chapter I contains a summary of this work and its major results together with an introduction to the scientific and engineering concepts associated with a superconducting power transmission line. Chapter II is a discussion of the physics of current transport and the associated loss mechanisms in a type-II superconductor. Chapter III gives the details of the electron-beam coevaporation technique developed to fabricate the samples for this study. Also discussed in this chapter are the effects of the evaporation conditions on the growth morphology of the niobium-tin films. Chapter IV presents the details of the experimental techniques developed to measure the ac loss and critical current in these samples as a function of temperature. Chapter V shows the dependence of the critical current of these films and composites on temperature, magnetic field, and on the number of artificially introduced pinning centers in the layered composites. Experimental results are also presented concerning the stability of these conductors against flux jumps. Chapter VI is a discussion of the ac losses in these samples. Detailed comparisons are made between the measured loss and the predictions of the critical state model

  2. Spectroscopic Observations and Analysis of the Unusual Type Ia SN1999ac

    International Nuclear Information System (INIS)

    Garavini, G.; Aldering, G.; Amadon, A.; Amanullah, R.; Astier, P.; Balland, C.; Blanc, G.; Conley, A.; Dahlen, T.; Deustua, S.E.; Ellis, R.; Fabbro, S.; Fadeyev, V.; Fan, X.; Folatelli, G.; Frye, B.; Gates, E.L.; Gibbons, R.; Goldhaber, G.; Goldman, B.; Goobar, A.; Groom, D.E.; Haissinski, J.; Hardin, D.; Hook, I.; Howell, D.A.; Kent, S.; Kim, A.G.; Knop, R.A.; Kowalski, M.; Kuznetsova, N.; Lee, B.C.; Lidman, C.; Mendez, J.; Miller, G.J.; Moniez, M.; Mouchet, M.; Mourao, A.; Newberg, H.; Nobili, S.; Nugent, P.E.; Pain, R.; Perdereau, O.; Perlmutter, S.; Quimby, R.; Regnault, N.; Rich, J.; Richards, G.T.; Ruiz-Lapuente, P.; Schaefer, B.E.; Schahmaneche, K.; Smith, E.; Spadafora, A.L.; Stanishev, V.; Thomas, R.C.; Walton, N.A.; Wang, L.; Wood-Vasey, W.M.

    2005-01-01

    The authors present optical spectra of the peculiar Type Ia supernova (SN Ia) 1999ac. The data extend from -15 to +42 days with respect to B-band maximum and reveal an event that is unusual in several respects. prior to B-band maximum, the spectra resemble those of SN 1999aa, a slowly declining event, but possess stronger Si II and Ca II signatures (more characteristic of a spectroscopically normal SN). Spectra after B-band maximum appear more normal. The expansion velocities inferred from the Iron lines appear to be lower than average; whereas, the expansion velocity inferred from Calcium H and K are higher than average. The expansion velocities inferred from the Iron lines appear to be lower than average; whereas, the expansion velocity inferred from Calcium H and K are higher than average. The expansion velocities inferred from Si II are among the slowest ever observed, though SN 1999ac is not particularly dim. The analysis of the parameters v 10 (Si II), R(Si II), v, and Δm 15 further underlines the unique characteristics of SN 1999ac. They find convincing evidence of C II λ6580 in the day -15 spectrum with ejection velocity v > 16,000 km s -1 , but this signature disappears by day -9. This rapid evolution at early times highlights the importance of extremely early-time spectroscopy

  3. Design, Realization and First Tests of a Prototype of Mower-Conditioner to Harvest Fibre Sorghum through Haymaking

    Energy Technology Data Exchange (ETDEWEB)

    Assirelli, A.; Pari, L. (Consiglio per la Ricerca e la Sperimentazione in Agricoltura, Unita di Ricerca per l' Ingegneria Agraria, Monterotondo, RM (Italy))

    2008-10-15

    The baling of dried fibre sorghum introduces some specific problems due mostly to stalk development, height and rigidity and to the volume of green biomass to process. To improve storage and to reduce transport cost, the main aspect to consider is the achievement of a satisfactory natural drying of the plant on the ground. Previous tests with mowers and mower-conditioners pointed out operational problems: the mowers, in relation to height and rigidity of the stalks, showed low working capacity, while the mower-conditioners, both with rolls or spokes, were not able to obtain a conditioning level good enough to achieve sufficient natural drying. The structure of the plant, particularly of its stalk, is such that without a continuous cleavage along the whole length, water content decreases slower than it would be suitable for harvesting period in Italy. Following these considerations, CRA-ING developed a back mounted harvester prototype, connected to the rear three-point linkage of a reversible drive tractor. Such equipment permits the cutting and conditioning of the whole plant, leaving it spread on the ground, without forming windrows, so to make full use of the solar radiation for drying. When the water contents drops to the optimum value for storing, the product can be collected in windrow and then baled with existing round balers or big balers. The adopted conditioning system is formed by six couples of longitudinal rolls, similar to those used in corn harvesting, because also the fibre sorghum is a row cultivation; each roll is provided with alternate blades and pads to press and cleave all along the stalk while pulling down the plant. Rolls dimensions and rotational speed are such to hit the stalk every 5 cm. Under the rolls, next to the ground, a saw cuts the plants. During the first year tests in Central Italy, the idea was confirmed successful: it was possible, working at 5 km/h speed, corresponding to 1,5 ha/h effective working capacity, to windrow and to

  4. Magnetic irreversibility in granular superconductors: ac susceptibility study

    International Nuclear Information System (INIS)

    Perez, F.; Obradors, X.; Fontcuberta, J.; Vallet, M.; Gonzalez-Calbet, J.

    1991-01-01

    Ac susceptibility measurements of a ceramic weak-coupled superconductor in very low ac fields (2mG, 111Hz) are reported. We present evidence for the observation of the magnetic irreversibility following a ZFC-FC thermal cycling by means of ac susceptibilty measurements. It is shown that this technique also reflect local magnetic field effects in granular superconductors, as previously suggested in microwave surface resistance and I-V characteristics. (orig.)

  5. Fault Detection And Diagnosis For Air Conditioners And Heat Pumps Based On Virtual Sensors

    OpenAIRE

    Kim, Woohyun

    2013-01-01

    The primary goal of this research is to develop and demonstrate an integrated, on-line performance monitoring and diagnostic system with low cost sensors for air conditioning and heat pump equipment. Automated fault detection and diagnostics (FDD) has the potential for improving energy efficiency along with reducing service costs and comfort complaints. To achieve this goal, virtual sensors with low cost measurements and simple models were developed to estimate quantities that would be expens...

  6. World lines.

    OpenAIRE

    Waser Jürgen; Fuchs Raphael; Ribicic Hrvoje; Schindler Benjamin; Blöschl Günther; Gröller Eduard

    2010-01-01

    In this paper we present World Lines as a novel interactive visualization that provides complete control over multiple heterogeneous simulation runs. In many application areas decisions can only be made by exploring alternative scenarios. The goal of the suggested approach is to support users in this decision making process. In this setting the data domain is extended to a set of alternative worlds where only one outcome will actually happen. World Lines integrate simulation visualization and...

  7. AC Own Motion Percentage of Randomly Sampled Cases

    Data.gov (United States)

    Social Security Administration — Longitudinal report detailing the numbers and percentages of Appeals Council (AC) own motion review actions taken on un-appealed favorable hearing level decisions...

  8. AC electric motors control advanced design techniques and applications

    CERN Document Server

    Giri, Fouad

    2013-01-01

    The complexity of AC motor control lies in the multivariable and nonlinear nature of AC machine dynamics. Recent advancements in control theory now make it possible to deal with long-standing problems in AC motors control. This text expertly draws on these developments to apply a wide range of model-based control designmethods to a variety of AC motors. Contributions from over thirty top researchers explain how modern control design methods can be used to achieve tight speed regulation, optimal energetic efficiency, and operation reliability and safety, by considering online state var

  9. Cosmic Shear With ACS Pure Parallels. Targeted Portion.

    Science.gov (United States)

    Rhodes, Jason

    2002-07-01

    Small distortions in the shapes of background galaxies by foreground mass provide a powerful method of directly measuring the amount and distribution of dark matter. Several groups have recently detected this weak lensing by large-scale structure, also called cosmic shear. The high resolution and sensitivity of HST/ACS provide a unique opportunity to measure cosmic shear accurately on small scales. Using 260 parallel orbits in Sloan i {F775W} we will measure for the first time: the cosmic shear variance on scales Omega_m^0.5, with signal-to-noise {s/n} 20, and the mass density Omega_m with s/n=4. They will be done at small angular scales where non-linear effects dominate the power spectrum, providing a test of the gravitational instability paradigm for structure formation. Measurements on these scales are not possible from the ground, because of the systematic effects induced by PSF smearing from seeing. Having many independent lines of sight reduces the uncertainty due to cosmic variance, making parallel observations ideal.

  10. Improved Design Methods for Robust Single- and Three-Phase ac-dc-ac Power Converters

    DEFF Research Database (Denmark)

    Qin, Zian

    . The approaches for improving their performance, in terms of the voltage stress, efficiency, power density, cost, loss distribution, and temperature, will be studied. The structure of the thesis is as follows, Chapter 1 presents the introduction and motivation of the whole project as well as the background...... becomes a emerging challenge. Accordingly, installation of sustainable power generators like wind turbines and solar panels has experienced a large increase during the last decades. Meanwhile, power electronics converters, as interfaces in electrical system, are delivering approximately 80 % electricity...... back-to-back, and meanwhile improve the harmonics, control flexibility, and thermal distribution between the switches. Afterwards, active power decoupling methods for single-phase inverters or rectifiers that are similar to the single-phase ac-dc-ac converter, are studied in Chapter 4...

  11. Wind-powered asynchronous AC/DC/AC converter system. [for electric power supply regulation

    Science.gov (United States)

    Reitan, D. K.

    1973-01-01

    Two asynchronous ac/dc/ac systems are modelled that utilize wind power to drive a variable or constant hertz alternator. The first system employs a high power 60-hertz inverter tie to the large backup supply of the power company to either supplement them from wind energy, storage, or from a combination of both at a preset desired current; rectifier and inverter are identical and operate in either mode depending on the silicon control rectifier firing angle. The second system employs the same rectification but from a 60-hertz alternator arrangement; it provides mainly dc output, some sinusoidal 60-hertz from the wind bus and some high harmonic content 60-hertz from an 800-watt inverter.

  12. Definitive determination of the transverse Hamiltonian parameters in the single molecule magnet Mn_12-Ac

    Science.gov (United States)

    Edwards, Rachel S.; Hill, Stephen; North, J. Micah; Dalal, Naresh; Jones, Shaela; Maccagnano, Sara

    2003-03-01

    We present high frequency high field electron paramagnetic resonance (EPR) measurements on the single molecule magnet Mn_12-Ac. Using a split coil magnet and highly sensitive resonant cavity techniques we are able to perform an angle dependent study of the single crystal EPR with the field applied in the hard plane, and hence unambiguously determine the transverse Hamiltonian parameters to fourth order. A variation in the line-shape of the resonances with angle supports the recent proposal of a ligand disorder in this material causing local quadratic anisotropy, and is used to determine the magnitude of the second order transverse term. This could have important implications for describing magnetic quantum tunneling in Mn_12-Ac. S. Hill, J.A.A.J. Perenboom, N.S. Dalal, T. Hathaway, T. Stalcup and J.S. Brooks, Phys. Rev. Lett. 80, 2453 (1998). A. Cornia, R. Sessoli, L. Sorace, D. Gatteschi, A.L. Barra and C. Daiguebonne, cond-mat/0112112.

  13. Experimental performance of R432A to replace R22 in residential air-conditioners and heat pumps

    International Nuclear Information System (INIS)

    Park, Ki-Jung; Shim, Yun-Bo; Jung, Dongsoo

    2009-01-01

    In this study, thermodynamic performance of R432A and HCFC22 is measured in a heat pump bench tester under both air-conditioning and heat pumping conditions. R432A has no ozone depletion potential and very low greenhouse warming potential of less than 5. R432A also offers a similar vapor pressure to HCFC22 for 'drop-in' replacement. Test results showed that the coefficient of performance and capacity of R432A are 8.5-8.7% and 1.9-6.4% higher than those of HCFC22 for both conditions. The compressor discharge temperature of R432A is 14.1-17.3 deg. C lower than that of HCFC22 while the amount of charge for R432A is 50% lower than that of HCFC22 due to its low density. Overall, R432A is a good long term 'drop-in' environmentally friendly alternative to replace HCFC22 in residential air-conditioners and heat pumps due to its excellent thermodynamic and environmental properties

  14. Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290

    International Nuclear Information System (INIS)

    Zhou, Guobing; Zhang, Yufeng

    2010-01-01

    This paper experimentally investigated the system performance of a split-type air conditioner matching with different coiled adiabatic capillary tubes for HCFC22 and HC290. Experiments were carried out in a room-type calorimeter. The results have shown that (1) similar cooling effects can be achieved by matching various capillary tubes of different inner diameters; (2) parallel capillary tubes presented better system performance and flow stability with weaker inlet pressure fluctuations than the single capillary tube; (3) with the coil diameter of the capillary tube increasing from 40 mm to 120 mm, the mass flow rate tended to increase slightly. But the cooling capacity, input power and energy efficiency ratio (EER) did not show evident tendency of change; (4) the refrigerant charge and mass flow rate for HC290 were only 44% and 47% of that for HCFC22, respectively, due to the much lower density. And HC290 had 4.7-6.7% lower cooling capacity and 12.1-12.3% lower input power with respect to HCFC22. However, the EER of HC290 can be 8.5% higher than that of HCFC22, which exhibits the advantage of using HC290. In addition, the experimental uncertainties were analyzed and some application concerns of HC290 were discussed.

  15. Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps

    International Nuclear Information System (INIS)

    Park, Ki-Jung; Shim, Yun-Bo; Jung, Dongsoo

    2008-01-01

    In this study, thermodynamic performance of R433A and HCFC22 is measured in a heat pump bench tester under air-conditioning and heat pumping conditions. R433A has no ozone depletion potential and very low greenhouse warming potential of less than 5. R433A also offers a similar vapor pressure to HCFC22 for possible 'drop-in' replacement. Test results showed that the coefficient of performance of R433A is 4.9-7.6% higher than that of HCFC22 while the capacity of R433A is 1.0-5.5% lower than that of HCFC22 for both conditions. The compressor discharge temperature of R433A is 22.6-27.9 deg. C lower than that of HCFC22 while the amount of charge for R433A is 57.0-57.7% lower than that of HCFC22 due to its low density. Overall, R433A is a good long term environmentally friendly alternative to replace HCFC22 in residential air-conditioners and heat pumps due to its excellent thermodynamic and environmental properties with minor adjustments

  16. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner.

    Science.gov (United States)

    Kim, Chul Jin; Choi, Hyo Hyun; Sohn, Chae Hoon

    2011-01-15

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 °C. First, its auto-ignition temperature is measured 365 °C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 °C to 255 °C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chul Jin; Choi, Hyo Hyun [Department of Mechanical Engineering, Sejong University, Seoul 143-747 (Korea, Republic of); Sohn, Chae Hoon, E-mail: chsohn@sejong.ac.kr [Department of Mechanical Engineering, Sejong University, Seoul 143-747 (Korea, Republic of)

    2011-01-15

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 deg. C. First, its auto-ignition temperature is measured 365 deg. C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 deg. C to 255 deg. C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor.

  18. Estimation of heat rejection based on the air conditioner use time and its mitigation from buildings in Taipei City

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Chun-Ming; Aramaki, Toshiya; Hanaki, Keisuke [The University of Tokyo, Bunkyo-ku, Tokyo (Japan). Department of Urban Engineering

    2007-09-15

    The main work in the research focuses on the analysis and mitigation of the anthropogenic heat discharged from buildings, which is one of the main reasons leading to the heat island effect. The residential and commercial buildings, divided into 10 categories, with HVAC systems were analyzed by the building energy program, EnergyPlus. With the help of GIS, the heat rejection of all the residential and commercial buildings in DaAn Ward of Taipei City were evaluated, in which the spatial data and diurnal variation of the heat rejection were described by 3-h time periods. Furthermore, the effect of mitigation strategies was discussed. The first strategy was to change the wall/roof material of building envelope. The second and third strategies, from the viewpoint of energy saving, were to change the temperature setting of air conditioners and to turn off the lighting and equipment when not in use. The fourth strategy was to use a better efficiency of the cooling systems. Finally, the evaluation of installing the water-cooled cooling system, which discharges heat in the form of sensible and latent heat, was also included. (author)

  19. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner

    International Nuclear Information System (INIS)

    Kim, Chul Jin; Choi, Hyo Hyun; Sohn, Chae Hoon

    2011-01-01

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 deg. C. First, its auto-ignition temperature is measured 365 deg. C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 deg. C to 255 deg. C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor.

  20. Performance of unified power quality conditioner (UPQC) based on fuzzy controller for attenuating of voltage and current harmonics

    Science.gov (United States)

    Milood Almelian, Mohamad; Mohd, Izzeldin I.; Asghaiyer Omran, Mohamed; Ullah Sheikh, Usman

    2018-04-01

    Power quality-related issues such as current and voltage distortions can adversely affect home and industrial appliances. Although several conventional techniques such as the use of passive and active filters have been developed to increase power quality standards, these methods have challenges and are inadequate due to the increasing number of applications. The Unified Power Quality Conditioner (UPQC) is a modern strategy towards correcting the imperfections of voltage and load current supply. A UPQC is a combination of both series and shunt active power filters in a back-to-back manner with a common DC link capacitor. The control of the voltage of the DC link capacitor is important in achieving a desired UPQC performance. In this paper, the UPQC with a Fuzzy logic controller (FLC) was used to precisely eliminate the imperfections of voltage and current harmonics. The results of the simulation studies using MATLAB/Simulink and Simpower system programming for R-L load associated through an uncontrolled bridge rectifier was used to assess the execution process. The UPQC with FLC was simulated for a system with distorted load current and a system with distorted source voltage and load current. The outcome of the comparison of %THD in the load current and source voltage before and after using UPQC for the two cases was presented.

  1. Swimming pools as heat sinks for air conditioners: Model design and experimental validation for natural thermal behavior of the pool

    Energy Technology Data Exchange (ETDEWEB)

    Woolley, Jonathan; Harrington, Curtis; Modera, Mark [University of California Davis, Western Cooling Efficiency Center, 1450 Drew Avenue, Suite 100, Davis, CA 95618 (United States)

    2011-01-15

    Swimming pools as thermal sinks for air conditioners could save approximately 40% on peak cooling power and 30% of overall cooling energy, compared to standard residential air conditioning. Heat dissipation from pools in semi-arid climates with large diurnal temperature shifts is such that pool heating and space cooling may occur concurrently; in which case heat rejected from cooling equipment could directly displace pool heating energy, while also improving space cooling efficiency. The performance of such a system relies on the natural temperature regulation of swimming pools governed by evaporative and convective heat exchange with the air, radiative heat exchange with the sky, and conductive heat exchange with the ground. This paper describes and validates a model that uses meteorological data to accurately predict the hourly temperature of a swimming pool to within 1.1 C maximum error over the period of observation. A thorough review of literature guided our choice of the most appropriate set of equations to describe the natural mass and energy exchange between a swimming pool and the environment. Monitoring of a pool in Davis, CA, was used to confirm the resulting simulations. Comparison of predicted and observed pool temperature for all hours over a 56 day experimental period shows an R-squared relatedness of 0.967. (author)

  2. Deacetylation of H4-K16Ac and heterochromatin assembly in senescence

    Directory of Open Access Journals (Sweden)

    Contrepois Kévin

    2012-08-01

    Full Text Available Abstract Background Cellular senescence is a stress response of mammalian cells leading to a durable arrest of cell proliferation that has been implicated in tumor suppression, wound healing, and aging. The proliferative arrest is mediated by transcriptional repression of genes essential for cell division by the retinoblastoma protein family. This repression is accompanied by varying degrees of heterochromatin assembly, but little is known regarding the molecular mechanisms involved. Results We found that both deacetylation of H4-K16Ac and expression of HMGA1/2 can contribute to DNA compaction during senescence. SIRT2, an NAD-dependent class III histone deacetylase, contributes to H4-K16Ac deacetylation and DNA compaction in human fibroblast cell lines that assemble striking senescence-associated heterochromatin foci (SAHFs. Decreased H4-K16Ac was observed in both replicative and oncogene-induced senescence of these cells. In contrast, this mechanism was inoperative in a fibroblast cell line that did not assemble extensive heterochromatin during senescence. Treatment of senescent cells with trichostatin A, a class I/II histone deacetylase inhibitor, also induced rapid and reversible decondensation of SAHFs. Inhibition of DNA compaction did not significantly affect the stability of the senescent state. Conclusions Variable DNA compaction observed during senescence is explained in part by cell-type specific regulation of H4 deacetylation and HMGA1/2 expression. Deacetylation of H4-K16Ac during senescence may explain reported decreases in this mark during mammalian aging and in cancer cells.

  3. Ac and dc motor flooding times

    International Nuclear Information System (INIS)

    Crowley, D.A.; Hinton, J.H.

    1988-01-01

    Reactor safety studies, such as the emergency cooling system (ECS) limits analyses and the probabilistic risk assessment, require that the flood-out times be calculated for the ac and dc motors at the -40 foot level. New calculations are needed because dams of an improved design have been installed between the pump room and motor room, and because updated leak rate calculations have shown that the maximum possible leak rate is larger than that which had been previously calculated. The methodology for calculating the motor flood-out times has also been improved. A computer program has been written to calculate flood-out times for various leak rates and sump pump operabilities. For ECS limits analyses, the worst case dc motor flood-out times are 161 and 297 seconds in LKC and P-areas, respectively. These times are for a 135,468 gpm leak that first flows to the motor room and all of the sump pumps are off

  4. Neurinoma central do nervo acústico

    Directory of Open Access Journals (Sweden)

    Paulo Pinto Pupo

    1950-03-01

    Full Text Available O autor apresenta o caso de uma paciente com 45 anos, com hipertensão arterial, queixando-se de tonturas e surdez progressiva à esquerda que, ao exame neurológico, apresentava síndrome protuberancial, com hemi-anestesia táctil e dolorosa à direita respeitando a face, hemiparesia direita, ataxia de tipo sensitivo nos membros da direita, paralisia facial de tipo periférico, hipoacusia, paresia de motor ocular externo à esquerda, síndrome vertiginosa e nistagmo horizontal ao olhar para a direita. À necrópsia foi encontrado um tumor na hemicalota protuberancial esquerda e foco malácico adjacente, secundário a distúrbio circulatório. O tumor, intimamente dependente das raízes intraprotuberanciais do nervo acústico, se apresentava com as características histológicas dos neurinomas. Além dessas particularidades, a lesão do feixe central da calota e conseqüente degeneração "hipertrófica" da oliva bulbar constituem outro aspecto de grande interêsse dêste caso.

  5. Silver linings.

    Science.gov (United States)

    Bultas, Margaret W; Pohlman, Shawn

    2014-01-01

    The purpose of this interpretive phenomenological study was to gain a better understanding of the experiences of 11 mothers of preschool children with autism spectrum disorder (ASD). Mothers were interviewed three times over a 6 week period. Interviews were analyzed using interpretive methods. This manuscript highlights one particular theme-a positive perspective mothers described as the "silver lining." This "silver lining" represents optimism despite the adversities associated with parenting a child with ASD. A deeper understanding of this side of mothering children with ASD may help health care providers improve rapport, communication, and result in more authentic family centered care. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Introduction of hvdc transmission into a predominantly ac network

    Energy Technology Data Exchange (ETDEWEB)

    Casson, W; Last, F H; Huddart, K W

    1966-02-01

    Methods for reinforcing the supply network, including systems employing dc links, without introducing a new primary network are briefly described. The arrangement for dc links is outlined and the application to an existing ac system is considered. The economics of ac and dc for reinforcement schemes are briefly mentioned.

  7. Low ac loss geometries in YBCO coated conductors

    International Nuclear Information System (INIS)

    Duckworth, R.C.; List, F.A.; Paranthaman, M.P.; Rupich, M.W.; Zhang, W.; Xie, Y.Y.; Selvamanickam, V.

    2007-01-01

    Reduction of ac losses in applied ac fields can be accomplished through either the creation of filaments and bridging in YBCO coated conductors or by an assembly of narrow width YBCO tapes. The ac losses for each of these geometries were measured at 77 K in perpendicular ac fields up to 100 mT. Despite physical isolation of the filaments, coupling losses were still present in the samples when compared to the expected hysteretic loss. In addition to filamentary conductors the assembly of stacked YBCO conductor provides an alternative method of ac loss reduction. When compared to a 4-mm wide YBCO coated conductor with a critical current of 60 A, the ac loss in a stack of 2-mm wide YBCO coated conductors with a similar total critical current was reduced. While the reduction in ac loss in a 2-mm wide stack coincided with the reduction in the engineering current density of the conductor, further reduction of ac loss was obtained through the splicing of the 2-mm wide tapes with low resistance solders

  8. Low ac loss geometries in YBCO coated conductors

    Energy Technology Data Exchange (ETDEWEB)

    Duckworth, R.C. [Oak Ridge National Laboratory, One Bethel Valley Road, P.O. Box 2008, MS-6305, Oak Ridge, TN 37831-6305 (United States)], E-mail: duckworthrc@ornl.gov; List, F.A.; Paranthaman, M.P. [Oak Ridge National Laboratory, One Bethel Valley Road, P.O. Box 2008, MS-6305, Oak Ridge, TN 37831-6305 (United States); Rupich, M.W.; Zhang, W. [American Superconductor, Two Technology Drive, Westborough, MA 01581 (United States); Xie, Y.Y.; Selvamanickam, V. [SuperPower, 450 Duane Ave, Schenectady, NY 12304 (United States)

    2007-10-01

    Reduction of ac losses in applied ac fields can be accomplished through either the creation of filaments and bridging in YBCO coated conductors or by an assembly of narrow width YBCO tapes. The ac losses for each of these geometries were measured at 77 K in perpendicular ac fields up to 100 mT. Despite physical isolation of the filaments, coupling losses were still present in the samples when compared to the expected hysteretic loss. In addition to filamentary conductors the assembly of stacked YBCO conductor provides an alternative method of ac loss reduction. When compared to a 4-mm wide YBCO coated conductor with a critical current of 60 A, the ac loss in a stack of 2-mm wide YBCO coated conductors with a similar total critical current was reduced. While the reduction in ac loss in a 2-mm wide stack coincided with the reduction in the engineering current density of the conductor, further reduction of ac loss was obtained through the splicing of the 2-mm wide tapes with low resistance solders.

  9. Flexible AC transmission systems: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Edris, Abdel-Aty [Electric Power Research Inst., Palo Alto, CA (United States). Electric Systems Division

    1994-12-31

    Flexible AC transmission systems (FACTS) is a concept promoting the use of power electronic controllers to enhance the controllability and usable capacity of AC transmission. This paper presents the state of the art of FACTS and the status of the current projects for the application of the FACTS controllers in transmission systems. (author) 8 refs., 8 figs.

  10. Ammonia treated Mo/AC catalysts for CO hydrogenation with ...

    Indian Academy of Sciences (India)

    SHARIF F ZAMAN

    the influence of acid treated AC as a support with K-Ni-. Mo active ... K-Ni-Mo/AC catalyst was more selective to oxygenates. (>40% ... mineral impurities (K, Si, Sn and Fe) <1%. ...... edge technical support with thanks Science and Technology.

  11. ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY I: TECHNIQUE FUNDAMENTALS

    Directory of Open Access Journals (Sweden)

    Róbinson Torres

    Full Text Available Basic fundamentals of AC electrogravimetry are introduced. Their main requirements and characteristics are detailed to establish the design of an electronic system that allows the appropriate extraction of data needed to determine the electrogravimetric transfer function (EGTF and electrochemical impedance (EI, in an experimental set-up for the AC electrogravimetry technique.

  12. Operation of AC Adapters Visualized Using Light-Emitting Diodes

    Science.gov (United States)

    Regester, Jeffrey

    2016-01-01

    A bridge rectifier is a diamond-shaped configuration of diodes that serves to convert alternating current(AC) into direct current (DC). In our world of AC outlets and DC electronics, they are ubiquitous. Of course, most bridge rectifiers are built with regular diodes, not the light-emitting variety, because LEDs have a number of disadvantages. For…

  13. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Science.gov (United States)

    2010-01-01

    ... an ACS are provided in RUS Telecommunications Engineering and Construction Manual section 205. (e... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage... the borrower's records contain sufficient information as to subscriber development to enable cost...

  14. 21 CFR 880.5500 - AC-powered patient lift.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5500 AC-powered patient lift. (a) Identification. An AC-powered lift is an electrically powered device either fixed or mobile, used to lift and transport patients in the horizontal or other...

  15. Effect of temperature on the AC impedance of protein

    Indian Academy of Sciences (India)

    The depression parameter reveals the electrical equivalent circuit for the biopolymers. The AC electrical conductivity in the biopolymers follows the universal power law. From this, it is observed that the AC conductivity is frequency dependent and the biopolymer papain obeys large polaron tunnelling model, gum acacia and ...

  16. Effect of temperature on the AC impedance of protein and ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... The depression parameter reveals the electrical equivalent circuit for the biopolymers. The AC electrical conductivity in the biopolymers follows the universal power law. From this, it is observed that the AC conductivity is frequency dependent and the biopolymer papain obeys large polaron tunnelling model ...

  17. VizieR Online Data Catalog: Hubble Legacy Archive ACS grism data (Kuemmel+, 2011)

    Science.gov (United States)

    Kuemmel, M.; Rosati, P.; Fosbury, R.; Haase, J.; Hook, R. N.; Kuntschner, H.; Lombardi, M.; Micol, A.; Nilsson, K. K.; Stoehr, F.; Walsh, J. R.

    2011-09-01

    A public release of slitless spectra, obtained with ACS/WFC and the G800L grism, is presented. Spectra were automatically extracted in a uniform way from 153 archival fields (or "associations") distributed across the two Galactic caps, covering all observations to 2008. The ACS G800L grism provides a wavelength range of 0.55-1.00um, with a dispersion of 40Å/pixel and a resolution of ~80Å for point-like sources. The ACS G800L images and matched direct images were reduced with an automatic pipeline that handles all steps from archive retrieval, alignment and astrometric calibration, direct image combination, catalogue generation, spectral extraction and collection of metadata. The large number of extracted spectra (73,581) demanded automatic methods for quality control and an automated classification algorithm was trained on the visual inspection of several thousand spectra. The final sample of quality controlled spectra includes 47919 datasets (65% of the total number of extracted spectra) for 32149 unique objects, with a median iAB-band magnitude of 23.7, reaching 26.5 AB for the faintest objects. Each released dataset contains science-ready 1D and 2D spectra, as well as multi-band image cutouts of corresponding sources and a useful preview page summarising the direct and slitless data, astrometric and photometric parameters. This release is part of the continuing effort to enhance the content of the Hubble Legacy Archive (HLA) with highly processed data products which significantly facilitate the scientific exploitation of the Hubble data. In order to characterize the slitless spectra, emission-line flux and equivalent width sensitivity of the ACS data were compared with public ground-based spectra in the GOODS-South field. An example list of emission line galaxies with two or more identified lines is also included, covering the redshift range 0.2-4.6. Almost all redshift determinations outside of the GOODS fields are new. The scope of science projects possible

  18. Levitação acústica

    OpenAIRE

    Andrade, Marco Aurélio Brizzotti; Pérez, Nicolás; Adamowski, Julio Cezar

    2015-01-01

    A levitação acústica pode ser uma ferramenta valiosa para auxiliar estudantes de graduação a aprender conceitos básicos de física, tais como movimento harmônico simples, ondas acústicas estacionárias, e energia potencial. Neste artigo, apresentamos o princípio de funcionamento de um levitador acústico e explicamos como aplicar as equações básicas da acústica para determinar a força de radiação acústica que atua numa esfera em uma onda estacionária. Acoustic levitation can be a valuable too...

  19. Characterisation of AC1: a naturally decaffeinated coffee

    Directory of Open Access Journals (Sweden)

    Luciana Benjamim Benatti

    2012-01-01

    Full Text Available We compared the biochemical characteristics of the beans of a naturally decaffeinated Arabica coffee (AC1 discovered in 2004 with those of the widely grown Brazilian Arabica cultivar "Mundo Novo" (MN. Although we observed differences during fruit development, the contents of amino acids, organic acids, chlorogenic acids, soluble sugars and trigonelline were similar in the ripe fruits of AC1 and MN. AC1 beans accumulated theobromine, and caffeine was almost entirely absent. Tests on the supply of [2-14C] adenine and enzymatic analysis of theobromine synthase and caffeine synthase in the endosperm of AC1 confirmed that, as in the leaves, caffeine synthesis is blocked during the methylation of theobromine to caffeine. The quality of the final coffee beverage obtained from AC1 was similar to that of MN.

  20. Estimation of the Thurstonian model for the 2-AC protocol

    DEFF Research Database (Denmark)

    Christensen, Rune Haubo Bojesen; Lee, Hye-Seong; Brockhoff, Per B.

    2012-01-01

    . This relationship makes it possible to extract estimates and standard errors of δ and τ from general statistical software, and furthermore, it makes it possible to combine standard regression modelling with the Thurstonian model for the 2-AC protocol. A model for replicated 2-AC data is proposed using cumulative......The 2-AC protocol is a 2-AFC protocol with a “no-difference” option and is technically identical to the paired preference test with a “no-preference” option. The Thurstonian model for the 2-AC protocol is parameterized by δ and a decision parameter τ, the estimates of which can be obtained...... by fairly simple well-known methods. In this paper we describe how standard errors of the parameters can be obtained and how exact power computations can be performed. We also show how the Thurstonian model for the 2-AC protocol is closely related to a statistical model known as a cumulative probit model...