WorldWideScience

Sample records for absorptivity

  1. [Study on lead absorption in pumpkin by atomic absorption spectrophotometry].

    Science.gov (United States)

    Li, Zhen-Xia; Sun, Yong-Dong; Chen, Bi-Hua; Li, Xin-Zheng

    2008-07-01

    A study was carried out on the characteristic of lead absorption in pumpkin via atomic absorption spectrophotometer. The results showed that lead absorption amount in pumpkin increased with time, but the absorption rate decreased with time; And the lead absorption amount reached the peak in pH 7. Lead and cadmium have similar characteristic of absorption in pumpkin.

  2. Absorption studies

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Absorption studies were once quite popular but hardly anyone does them these days. It is easier to estimate the blood level of the nutrient directly by radioimmunoassay (RIA). However, the information obtained by estimating the blood levels of the nutrients is not the same that can be obtained from the absorption studies. Absorption studies are primarily done to find out whether some of the essential nutrients are absorbed from the gut or not and if they are absorbed, to determine how much is being absorbed. In the advanced countries, these tests were mostly done to detect pernicious anaemia where vitamin B 12 is not absorbed because of the lack of the intrinsic factor in the stomach. In the tropical countries, ''malabsorption syndrome'' is quire common. In this condition, several nutrients like fat, folic acid and vitamin B 12 are not absorbed. It is possible to study absorption of these nutrients by radioisotopic absorption studies

  3. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  4. Quasar Absorption Studies

    Science.gov (United States)

    Mushotzky, Richard (Technical Monitor); Elvis, Martin

    2004-01-01

    The aim of the proposal is to investigate the absorption properties of a sample of inter-mediate redshift quasars. The main goals of the project are: Measure the redshift and the column density of the X-ray absorbers; test the correlation between absorption and redshift suggested by ROSAT and ASCA data; constrain the absorber ionization status and metallicity; constrain the absorber dust content and composition through the comparison between the amount of X-ray absorption and optical dust extinction. Unanticipated low energy cut-offs where discovered in ROSAT spectra of quasars and confirmed by ASCA, BeppoSAX and Chandra. In most cases it was not possible to constrain adequately the redshift of the absorber from the X-ray data alone. Two possibilities remain open: a) absorption at the quasar redshift; and b) intervening absorption. The evidences in favour of intrinsic absorption are all indirect. Sensitive XMM observations can discriminate between these different scenarios. If the absorption is at the quasar redshift we can study whether the quasar environment evolves with the Cosmic time.

  5. Polarization control of intermediate state absorption in resonance-mediated multi-photon absorption process

    International Nuclear Information System (INIS)

    Xu, Shuwu; Yao, Yunhua; Jia, Tianqing; Ding, Jingxin; Zhang, Shian; Sun, Zhenrong; Huang, Yunxia

    2015-01-01

    We theoretically and experimentally demonstrate the control of the intermediate state absorption in an (n + m) resonance-mediated multi-photon absorption process by the polarization-modulated femtosecond laser pulse. An analytical solution of the intermediate state absorption in a resonance-mediated multi-photon absorption process is obtained based on the time-dependent perturbation theory. Our theoretical results show that the control efficiency of the intermediate state absorption by the polarization modulation is independent of the laser intensity when the transition from the intermediate state to the final state is coupled by the single-photon absorption, but will be affected by the laser intensity when this transition is coupled by the non-resonant multi-photon absorption. These theoretical results are experimentally confirmed via a two-photon fluorescence control in (2 + 1) resonance-mediated three-photon absorption of Coumarin 480 dye and a single-photon fluorescence control in (1 + 2) resonance-mediated three-photon absorption of IR 125 dye. (paper)

  6. Calcium absorption and achlorhydria

    International Nuclear Information System (INIS)

    Recker, R.R.

    1985-01-01

    Defective absorption of calcium has been thought to exist in patients with achlorhydria. The author compared absorption of calcium in its carbonate form with that in a pH-adjusted citrate form in a group of 11 fasting patients with achlorhydria and in 9 fasting normal subjects. Fractional calcium absorption was measured by a modified double-isotope procedure with 0.25 g of calcium used as the carrier. Mean calcium absorption (+/- S.D.) in the patients with achlorhydria was 0.452 +/- 0.125 for citrate and 0.042 +/- 0.021 for carbonate (P less than 0.0001). Fractional calcium absorption in the normal subjects was 0.243 +/- 0.049 for citrate and 0.225 +/- 0.108 for carbonate (not significant). Absorption of calcium from carbonate in patients with achlorhydria was significantly lower than in the normal subjects and was lower than absorption from citrate in either group; absorption from citrate in those with achlorhydria was significantly higher than in the normal subjects, as well as higher than absorption from carbonate in either group. Administration of calcium carbonate as part of a normal breakfast resulted in completely normal absorption in the achlorhydric subjects. These results indicate that calcium absorption from carbonate is impaired in achlorhydria under fasting conditions. Since achlorhydria is common in older persons, calcium carbonate may not be the ideal dietary supplement

  7. Review on absorption technology with emphasis on small capacity absorption machines

    Directory of Open Access Journals (Sweden)

    Labus Jerko M.

    2013-01-01

    Full Text Available The aim of this paper is to review the past achievements in the field of absorption systems, their potential and possible directions for future development. Various types of absorption systems and research on working fluids are discussed in detail. Among various applications, solar cooling and combined cooling, heating and power (CCHP are identified as two most promising applications for further development of absorption machines. Under the same framework, special attention is given to the small capacity absorption machines and their current status at the market. Although this technology looks promising, it is still in development and many issues are open. With respect to that fact, this paper covers all the relevant aspects for further development of small capacity absorption machines.

  8. Folate absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Folate is the generic term given to numerous compounds of pteroic acid with glutamic acid. Knowledge of absorption is limited because of the complexities introduced by the variety of compounds and because of the inadequacy of investigational methods. Two assay methods are in use, namely microbiological and radioactive. Techniques used to study absorption include measurement of urinary excretion, serum concentration, faecal excretion, intestinal perfusion, and haematological response. It is probably necessary to test absorption of both pteroylmonoglutamic acid and one or more polyglutamates, and such tests would be facilitated by availability of synthesized compounds labelled with radioactive tracers at specifically selected sites. (author)

  9. Thermodynamic performance optimization of the absorption-generation process in an absorption refrigeration cycle

    International Nuclear Information System (INIS)

    Chen, Yi; Han, Wei; Jin, Hongguang

    2016-01-01

    Highlights: • This paper proposes a new thermal compressor model with boost pressure ratio. • The proposed model is an effective way to optimize the absorption-generation process. • Boost pressure ratio is a key parameter in the proposed thermal compressor model. • The optimum boost pressure ratios for two typical refrigeration systems are obtained. - Abstract: The absorption refrigeration cycle is a basic cycle that establishes the systems for utilizing mid-low temperature heat sources. A new thermal compressor model with a key parameter of boost pressure ratio is proposed to optimize the absorption-generation process. The ultimate generation pressure and boost pressure ratio are used to represent the potential and operating conditions of the thermal compressor, respectively. Using the proposed thermal compressor model, the operation mechanism and requirements of the absorption refrigeration system and absorption-compression refrigeration system are elucidated. Furthermore, the two typical heat conversion systems are optimized based on the thermal compressor model. The optimum boost pressure ratios of the absorption refrigeration system and the absorption-compression refrigeration system are 0.5 and 0.75, respectively. For the absorption refrigeration system, the optimum generation temperature is 125.31 °C at the cooling water temperature of 30 °C, which is obtained by simple thermodynamic calculation. The optimized thermodynamic performance of the absorption-compression refrigeration system is 16.7% higher than that of the conventional absorption refrigeration system when the generation temperature is 100 °C. The thermal compressor model proposed in this paper is an effective method for simplifying the optimization of the thermodynamic systems involving an absorption-generation process.

  10. Calcium absorption

    International Nuclear Information System (INIS)

    Carlmark, B.; Reizenstein, P.; Dudley, R.A.

    1976-01-01

    The methods most commonly used to measure the absorption and retention of orally administered calcium are reviewed. Nearly all make use of calcium radioisotopes. The magnitude of calcium absorption and retention depends upon the chemical form and amount of calcium administered, and the clinical and nutritional status of the subject; these influences are briefly surveyed. (author)

  11. Particulate absorption properties in the Red Sea from hyperspectral particulate absorption spectra

    KAUST Repository

    Tiwari, Surya Prakash

    2018-03-16

    This paper aims to describe the variability of particulate absorption properties using a unique hyperspectral dataset collected in the Red Sea as part of the TARA Oceans expedition. The absorption contributions by phytoplankton (aph) and non-algal particles (aNAP) to the total particulate absorption coefficients are determined using a numerical decomposition method (NDM). The NDM is validated by comparing the NDM derived values of aph and aNAP with simulated values of aph and aNAP are found to be in excellent agreement for the selected wavelengths (i.e., 443, 490, 555, and 676nm) with high correlation coefficient (R2), low root mean square error (RMSE), mean relative error (MRE), and with a slope close to unity. Further analyses showed that the total particulate absorption coefficients (i.e., ap(443)average = 0.01995m−1) were dominated by phytoplankton absorption (i.e., aph(443)average = 0.01743m−1) with a smaller contribution by non-algal particles absorption (i.e., aNAP(443)average = 0.002524m−1). The chlorophyll a is computed using the absorption based Line Height Method (LHM). The derived chlorophyll-specific absorption ((a⁎ph = aph(λ)/ChlLH)) showed more variability in the blue part of spectrum as compared to the red part of spectrum representative of the package effect and changes in pigment composition. A new parametrization proposed also enabled the reconstruction of a⁎ph(λ) for the Red Sea. Comparison of derived spectral constants with the spectral constants of existing models showed that our study A(λ) values are consistent with the existing values, despite there is a divergence with the B(λ) values. This study provides valuable information derived from the particulate absorption properties and its spectral variability and this would help us to determine the relationship between the phytoplankton absorption coefficients and chlorophyll a and its host of variables for the Red Sea.

  12. Vitamin A absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Investigation of the absorption of vitamin A and related substances is complicated by the multiplicity of forms in which they occur in the diet and by the possibility that they may be subject to different mechanisms of absorption. Present knowledge of these mechanisms is inadequate, especially in the case of carotenoids. Numerous tests of absorption have been developed. The most common has been the biochemical measurement of the rise in plasma vitamin A after an oral dose of retinol or retinyl ester, but standardization is inadequate. Radioisotope tests based upon assay of serum or faecal activity following oral administration of tritiated vitamin A derivaties hold considerable promise, but again standardization is inadequate. From investigations hitherto performed it is known that absorption of vitamin A is influenced by several diseases, although as yet the consistency of results and the correlation with other tests of intestinal function have often been poor. However, the test of vitamin A absorption is nevertheless of clinical importance as a specialized measure of intestinal function. (author)

  13. D-xylose absorption

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003606.htm D-xylose absorption To use the sharing features on this page, please enable JavaScript. D-xylose absorption is a laboratory test to determine ...

  14. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  15. Absorption and excretion tests

    International Nuclear Information System (INIS)

    Berberich, R.

    1988-01-01

    The absorption and excretion of radiopharmaceuticals is still of interest in diagnostic investigations of nuclear medicine. In this paper the most common methods of measuring absorption and excretion are described. The performance of the different tests and their standard values are discussed. More over the basic possibilities of measuring absorption and excretion including the needed measurement equipments are presented. (orig.) [de

  16. Total photon absorption

    International Nuclear Information System (INIS)

    Carlos, P.

    1985-06-01

    The present discussion is limited to a presentation of the most recent total photonuclear absorption experiments performed with real photons at intermediate energy, and more precisely in the region of nucleon resonances. The main sources of real photons are briefly reviewed and the experimental procedures used for total photonuclear absorption cross section measurements. The main results obtained below 140 MeV photon energy as well as above 2 GeV are recalled. The experimental study of total photonuclear absorption in the nuclear resonance region (140 MeV< E<2 GeV) is still at its beginning and some results are presented

  17. Subgap absorption in conjugated polymers

    Energy Technology Data Exchange (ETDEWEB)

    Sinclair, M.; Seager, C.H. (Sandia National Labs., Albuquerque, NM (USA)); McBranch, D.; Heeger, A.J. (California Univ., Santa Barbara, CA (USA)); Baker, G.L. (Bell Communications Research, Inc., Red Bank, NJ (USA))

    1991-01-01

    Along with X{sup (3)}, the magnitude of the optical absorption in the transparent window below the principal absorption edge is an important parameter which will ultimately determine the utility of conjugated polymers in active integrated optical devices. With an absorptance sensitivity of < 10{sup {minus}5}, Photothermal Deflection Spectroscopy (PDS) is ideal for determining the absorption coefficients of thin films of transparent'' materials. We have used PDS to measure the optical absorption spectra of the conjugated polymers poly(1,4-phenylene-vinylene) (and derivitives) and polydiacetylene-4BCMU in the spectral region from 0.55 eV to 3 eV. Our spectra show that the shape of the absorption edge varies considerably from polymer to polymer, with polydiacetylene-4BCMU having the steepest absorption edge. The minimum absorption coefficients measured varied somewhat with sample age and quality, but were typically in the range 1 cm{sup {minus}1} to 10 cm{sup {minus}1}. In the region below 1 eV, overtones of C-H stretching modes were observed, indicating that further improvements in transparency in this spectral region might be achieved via deuteration of fluorination. 11 refs., 4 figs.

  18. Absorption of acoustic waves by sunspots. II - Resonance absorption in axisymmetric fibril models

    Science.gov (United States)

    Rosenthal, C. S.

    1992-01-01

    Analytical calculations of acoustic waves scattered by sunspots which concentrate on the absorption at the magnetohydrodynamic Alfven resonance are extended to the case of a flux-tube embedded in a uniform atmosphere. The model is based on a flux-tubes of varying radius that are highly structured, translationally invariant, and axisymmetric. The absorbed fractional energy is determined for different flux-densities and subphotospheric locations with attention given to the effects of twist. When the flux is highly concentrated into annuli efficient absorption is possible even when the mean magnetic flux density is low. The model demonstrates low absorption at low azimuthal orders even in the presence of twist which generally increases the range of wave numbers over which efficient absorption can occur. Resonance absorption is concluded to be an efficient mechanism in monolithic sunspots, fibril sunspots, and plage fields.

  19. Subgap Absorption in Conjugated Polymers

    Science.gov (United States)

    Sinclair, M.; Seager, C. H.; McBranch, D.; Heeger, A. J; Baker, G. L.

    1991-01-01

    Along with X{sup (3)}, the magnitude of the optical absorption in the transparent window below the principal absorption edge is an important parameter which will ultimately determine the utility of conjugated polymers in active integrated optical devices. With an absorptance sensitivity of materials. We have used PDS to measure the optical absorption spectra of the conjugated polymers poly(1,4-phenylene-vinylene) (and derivitives) and polydiacetylene-4BCMU in the spectral region from 0.55 eV to 3 eV. Our spectra show that the shape of the absorption edge varies considerably from polymer to polymer, with polydiacetylene-4BCMU having the steepest absorption edge. The minimum absorption coefficients measured varied somewhat with sample age and quality, but were typically in the range 1 cm{sup {minus}1} to 10 cm{sup {minus}1}. In the region below 1 eV, overtones of C-H stretching modes were observed, indicating that further improvements in transparency in this spectral region might be achieved via deuteration of fluorination.

  20. Geospatial Absorption and Regional Effects

    Directory of Open Access Journals (Sweden)

    IOAN MAC

    2009-01-01

    Full Text Available The geospatial absorptions are characterized by a specific complexity both in content and in their phenomenological and spatial manifestation fields. Such processes are differentiated according to their specificity to pre-absorption, absorption or post-absorption. The mechanisms that contribute to absorption are extremely numerous: aggregation, extension, diffusion, substitution, resistivity (resilience, stratification, borrowings, etc. Between these mechanisms frequent relations are established determining an amplification of the process and of its regional effects. The installation of the geographic osmosis phenomenon in a given territory (a place for example leads to a homogenization of the geospatial state and to the installation of the regional homogeneity.

  1. Particulate absorption properties in the Red Sea from hyperspectral particulate absorption spectra

    KAUST Repository

    Tiwari, Surya Prakash; Zarokanellos, Nikolaos; Kheireddine, Malika; Shanmugam, Palanisamy; Jones, Burton

    2018-01-01

    This paper aims to describe the variability of particulate absorption properties using a unique hyperspectral dataset collected in the Red Sea as part of the TARA Oceans expedition. The absorption contributions by phytoplankton (aph) and non

  2. Multifunctional hybrids for electromagnetic absorption

    International Nuclear Information System (INIS)

    Huynen, I.; Quievy, N.; Bailly, C.; Bollen, P.; Detrembleur, C.; Eggermont, S.; Molenberg, I.; Thomassin, J.M.; Urbanczyk, L.

    2011-01-01

    Highlights: → EM absorption requires low dielectric constant and ∼1 S/m electrical conductivity. → New hybrids were processed with CNT-filled polymer foam inserted in Al honeycomb. → The EM absorption in the GHz range is superior to any known material. → A closed form model is used to guide the design of the hybrid. → The architectured material is light with potential for thermal management. - Abstract: Electromagnetic (EM) interferences are ubiquitous in modern technologies and impact on the reliability of electronic devices and on living cells. Shielding by EM absorption, which is preferable over reflection in certain instances, requires combining a low dielectric constant with high electrical conductivity, which are antagonist properties in the world of materials. A novel class of hybrid materials for EM absorption in the gigahertz range has been developed based on a hierarchical architecture involving a metallic honeycomb filled with a carbon nanotube-reinforced polymer foam. The waveguide characteristics of the honeycomb combined with the performance of the foam lead to unexpectedly large EM power absorption over a wide frequency range, superior to any known material. The peak absorption frequency can be tuned by varying the shape of the honeycomb unit cell. A closed form model of the EM reflection and absorption provides a tool for the optimization of the hybrid. This designed material sets the stage for a new class of sandwich panels combining high EM absorption with mass efficiency, stiffness and thermal management.

  3. The absorption of carbon monoxide in COSORB solutions: absorption rate and capacity

    NARCIS (Netherlands)

    Hogendoorn, Kees; van Swaaij, Willibrordus Petrus Maria; Versteeg, Geert

    1995-01-01

    Absorption rate experiments and equilibrium experiments were carried out for the COSORB reaction at 300 K. The equilibrium data at 300 K could reasonably well be described with the following relation: [...] Determination of the kinetics and mechanism of a chemical reaction by means of absorption

  4. Uranium absorption study pile

    International Nuclear Information System (INIS)

    Raievski, V.; Sautiez, B.

    1959-01-01

    The report describes a pile designed to measure the absorption of fuel slugs. The pile is of graphite and comprises a central section composed of uranium rods in a regular lattice. RaBe sources and BF 3 counters are situated on either side of the center. A given uranium charge is compared with a specimen charge of about 560 kg, and the difference in absorption between the two noted. The sensitivity of the equipment will detect absorption variations of about a few ppm boron (10 -6 boron per gr. of uranium) or better. (author) [fr

  5. Examination of the Measurement of Absorption Using the Reverberant Room Method for Highly Absorptive Acoustic Foam

    Science.gov (United States)

    Hughes, William O.; McNelis, Anne M.; Chris Nottoli; Eric Wolfram

    2015-01-01

    The absorption coefficient for material specimens are needed to quantify the expected acoustic performance of that material in its actual usage and environment. The ASTM C423-09a standard, "Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberant Room Method" is often used to measure the absorption coefficient of material test specimens. This method has its basics in the Sabine formula. Although widely used, the interpretation of these measurements are a topic of interest. For example, in certain cases the measured Sabine absorption coefficients are greater than 1.0 for highly absorptive materials. This is often attributed to the diffraction edge effect phenomenon. An investigative test program to measure the absorption properties of highly absorbent melamine foam has been performed at the Riverbank Acoustical Laboratories. This paper will present and discuss the test results relating to the effect of the test materials' surface area, thickness and edge sealing conditions. A follow-on paper is envisioned that will present and discuss the results relating to the spacing between multiple piece specimens, and the mounting condition of the test specimen.

  6. Linear photophysics, two-photon absorption and femtosecond transient absorption spectroscopy of styryl dye bases

    Energy Technology Data Exchange (ETDEWEB)

    Shaydyuk, Ye.O. [Institute of Physics, Prospect Nauki, 46, Kyiv-28 03028 Ukraine (Ukraine); Levchenko, S.M. [Institute of Molecular Biology and Genetics, 150, Akademika Zabolotnoho Str., Kyiv 036803 (Ukraine); Kurhuzenkau, S.A. [Department of Chemistry, University of Parma, Parco Area delle Scienze 17/A, Parma 43124 (Italy); Anderson, D. [NanoScienece Technology Center, University of Central Florida, 12424 Research Parkway, PAV400, Orlando, FL 32826 (United States); Department of Chemistry, University of Central Florida, 4111 Libra Drive, PSB225, Orlando, FL 32816 (United States); Masunov, A.E. [NanoScienece Technology Center, University of Central Florida, 12424 Research Parkway, PAV400, Orlando, FL 32826 (United States); Department of Chemistry, University of Central Florida, 4111 Libra Drive, PSB225, Orlando, FL 32816 (United States); South Ural State University, Lenin pr. 76, Chelyabinsk 454080 (Russian Federation); Department of Condensed Matter Physics, National Research Nuclear University MEPhI, Kashirskoye shosse 31, Moscow 115409 (Russian Federation); Photochemistry Center RAS, ul. Novatorov 7a, Moscow 119421 (Russian Federation); Kachkovsky, O.D.; Slominsky, Yu.L.; Bricks, J.L. [Insitute of Organic Chemistry, Murmanskaya Street, 5, Kyiv 03094 (Ukraine); Belfield, K.D. [College of Science and Liberal Arts, New Jersey Institute of Technology, University Heights, Newark, NJ 07102 (United States); School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an, 710062 (China); Bondar, M.V., E-mail: mbondar@mail.ucf.edu [Institute of Physics, Prospect Nauki, 46, Kyiv-28 03028 Ukraine (Ukraine)

    2017-03-15

    The steady-state and time-resolved linear spectral properties, two-photon absorption spectra and fast relaxation processes in the excited states of styryl base-type derivatives were investigated. The nature of linear absorption, fluorescence and excitation anisotropy spectra were analyzed in solvents of different polarity at room temperature and specific dependence of the solvatochromic behavior on the donor-acceptor strength of the terminal substituents was shown. Two-photon absorption (2PA) efficiency of styryl dye bases was determined in a broad spectral range using two-photon induced fluorescence technique, and cross-sections maxima of ~ 100 GM were found. The excited state absorption (ESA) and fast relaxation processes in the molecular structures were investigated by transient absorption femtosecond pump-probe methodology. The role of twisted intramolecular charge transfer (TICT) effect in the excited state of styryl dye base with dimethylamino substituent was shown. The experimental spectroscopic data were also verified by quantum chemical calculations at the Time Dependent Density Functional Theory level, combined with a polarizable continuum model.

  7. Iron absorption in relation to iron status

    International Nuclear Information System (INIS)

    Magnusson, B.; Bjoern-Rasmussen, E.; Hallberg, L.; Rossander, L.

    1981-01-01

    The absorption from a 3 mg dose of ferrous iron was measured in 250 male subjects. The absorption was related to the log concentration of serum ferritin in 186 subjects of whom 99 were regular blood donors (r= -0.76), and to bone marrow haemosiderin grading in 52 subjects with varying iron status. The purpose was to try and establish a percentage absorption from such a dose that is representative of subjects who are borderline iron deficient. This information is necessary for food iron absorption studies in order (1) to calculate the absorption of iron from the diet at a given iron status and (2) compare the absorption of iron from different meals studied in different groups of subjects by different investigarors. The results suggest that an absorption of about 40% of a 3 mg reference dose of ferrous iron is given in a fasting state, roughly corresponds to the absorption in borderline-iron-deficient subjects. The results indicate that this 40% absorption value corresponds to a serum ferritin level of 30 μg/l and that food iron absorption in a group of subjects should be expressed preferably as the absorption corresponding to a reference-dose absorption of 45%, or possibly a serum ferritin level of 30 μg/l. (author)

  8. Nutrition and magnesium absorption

    NARCIS (Netherlands)

    Brink, E.J.

    1992-01-01

    The influence of various nutrients present in dairy products and soybean-based products on absorption of magnesium has been investigated. The studies demonstrate that soybean protein versus casein lowers apparent magnesium absorption in rats through its phytate component. However, true

  9. Uranium absorption study pile; Empilement pour le controle de l'absorption de l'uranium

    Energy Technology Data Exchange (ETDEWEB)

    Raievski, V; Sautiez, B [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    The report describes a pile designed to measure the absorption of fuel slugs. The pile is of graphite and comprises a central section composed of uranium rods in a regular lattice. RaBe sources and BF{sub 3} counters are situated on either side of the center. A given uranium charge is compared with a specimen charge of about 560 kg, and the difference in absorption between the two noted. The sensitivity of the equipment will detect absorption variations of about a few ppm boron (10{sup -6} boron per gr. of uranium) or better. (author) [French] Nous decrivons un dispositif permettant de mesurer l'absorption des elements combustibles d'une pile. Ce dispositif est constitue par un empilement de graphite dont la region centrale est formee par un reseau regulier de barres d'uranium. Des sources de RaBe et des compteurs a BF{sub 3} sont places de part et d'autre de cette region. En comparant un chargement d'uranium a un chargement etalon d'environ 560 kg, on peut determiner la difference d'absorption entre ces deux chargements. La sensibilite permettrait de deceler une variation d'absorption de l'ordre du ppm de bore (10{sup -6} g de bore par gramme d'uranium) et peut-etre mieux. (auteur)

  10. Unusual continuous dual absorption peaks in Ca-doped BiFeO3 nanostructures for broadened microwave absorption

    Science.gov (United States)

    Li, Zhong-Jun; Hou, Zhi-Ling; Song, Wei-Li; Liu, Xing-Da; Cao, Wen-Qiang; Shao, Xiao-Hong; Cao, Mao-Sheng

    2016-05-01

    Electromagnetic absorption materials have received increasing attention owing to their wide applications in aerospace, communication and the electronics industry, and multiferroic materials with both polarization and magnetic properties are considered promising ceramics for microwave absorption application. However, the insufficient absorption intensity coupled with the narrow effective absorption bandwidth has limited the development of high-performance multiferroic materials for practical microwave absorption. To address such issues, in the present work, we utilize interfacial engineering in BiFeO3 nanoparticles via Ca doping, with the purpose of tailoring the phase boundary. Upon Ca-substitution, the co-existence of both R3c and P4mm phases has been confirmed to massively enhance both dielectric and magnetic properties via manipulating the phase boundary and the destruction of the spiral spin structure. Unlike the commonly reported magnetic/dielectric hybrid microwave absorption composites, Bi0.95Ca0.05FeO3 has been found to deliver unusual continuous dual absorption peaks at a small thickness (1.56 mm), which has remarkably broadened the effective absorption bandwidth (8.7-12.1 GHz). The fundamental mechanisms based on the phase boundary engineering have been discussed, suggesting a novel platform for designing advanced multiferroic materials with wide applications.Electromagnetic absorption materials have received increasing attention owing to their wide applications in aerospace, communication and the electronics industry, and multiferroic materials with both polarization and magnetic properties are considered promising ceramics for microwave absorption application. However, the insufficient absorption intensity coupled with the narrow effective absorption bandwidth has limited the development of high-performance multiferroic materials for practical microwave absorption. To address such issues, in the present work, we utilize interfacial engineering in BiFeO3

  11. An inulin-type fructan enhances calcium absorption primarily via an effect on colonic absorption in humans

    Science.gov (United States)

    Calcium absorption efficiency and bone mineral mass are increased in adolescents who regularly consume inulin-type fructans (ITF). The mechanism of action in increasing absorption is unknown but may be related to increased colonic calcium absorption. We conducted a study in young adults designed to ...

  12. Solar absorption surface panel

    Science.gov (United States)

    Santala, Teuvo J.

    1978-01-01

    A composite metal of aluminum and nickel is used to form an economical solar absorption surface for a collector plate wherein an intermetallic compound of the aluminum and nickel provides a surface morphology with high absorptance and relatively low infrared emittance along with good durability.

  13. Absorption of controlled-release iron

    International Nuclear Information System (INIS)

    Cook, J.D.; Lipschitz, D.A.; Skikne, B.S.

    1982-01-01

    A multiple-dose double radioiron technic was used to compare absorption of iron administered as a controlled release (CR) capsule and as an elixir; both formulations contained 50 mg elemental iron as ferrous sulfate. When taken by normal subjects in the fasting state, mean absorption from the elixir and CR capsule averaged 4.92% and 4.38%, which gave a CR capsule:elixir ratio of 0.89. This difference was not significant, but when taken with meals that inhibit absorption of dietary iron by different degrees, absorption of the CR formulation was superior. CR capsule:elixir absorption ratios averaged 1.70 from a meal that is mildly inhibitory and 3.13 from a meal that causes more marked inhibition. It is concluded that CR iron formulations may offer a therapeutic advantage to patients who take oral iron with meals to avoid gastrointestinal side effects

  14. Nonlinear effects in collective absorption

    International Nuclear Information System (INIS)

    Uenoyama, Takeshi; Mima, Kunioki; Watanabe, Tsuguhiro.

    1981-01-01

    The collective absorption of high intensity laser radiation is analyzed numerically. Density profile modification due to the ponderomotive force associating laser radiation and the excited electron plasma waves is self-consistently taken into account, and the intensity dependences of the absorption efficiency are obtained. In the high intensity regime, the absorption efficiency is found to be strongly enhanced in the plasma without flow, but reduced with supersonic flow. (author)

  15. Unusual continuous dual absorption peaks in Ca-doped BiFeO3 nanostructures for broadened microwave absorption.

    Science.gov (United States)

    Li, Zhong-Jun; Hou, Zhi-Ling; Song, Wei-Li; Liu, Xing-Da; Cao, Wen-Qiang; Shao, Xiao-Hong; Cao, Mao-Sheng

    2016-05-21

    Electromagnetic absorption materials have received increasing attention owing to their wide applications in aerospace, communication and the electronics industry, and multiferroic materials with both polarization and magnetic properties are considered promising ceramics for microwave absorption application. However, the insufficient absorption intensity coupled with the narrow effective absorption bandwidth has limited the development of high-performance multiferroic materials for practical microwave absorption. To address such issues, in the present work, we utilize interfacial engineering in BiFeO3 nanoparticles via Ca doping, with the purpose of tailoring the phase boundary. Upon Ca-substitution, the co-existence of both R3c and P4mm phases has been confirmed to massively enhance both dielectric and magnetic properties via manipulating the phase boundary and the destruction of the spiral spin structure. Unlike the commonly reported magnetic/dielectric hybrid microwave absorption composites, Bi0.95Ca0.05FeO3 has been found to deliver unusual continuous dual absorption peaks at a small thickness (1.56 mm), which has remarkably broadened the effective absorption bandwidth (8.7-12.1 GHz). The fundamental mechanisms based on the phase boundary engineering have been discussed, suggesting a novel platform for designing advanced multiferroic materials with wide applications.

  16. Ultrasonic absorption in solid specimens

    International Nuclear Information System (INIS)

    Siwabessy, P.J. W.; Stewart, G.A.

    1996-01-01

    As part of a project to measure the absorption of high frequency (50 - 500 kHz) sonar signals in warm sea-water, a laboratory apparatus has been constructed and tested against room temperature distilled water and various solutions of MgSO 4 (chemical relaxation of MgSO 4 is the major contribution to absorption below 200 kHz). The technique involves monitoring the decay of an acoustic signal for different sizes of vessels of water suspended in an evacuated chamber. So far, all containing vessels used have been spherical in shape. Extrapolation of the results to infinite volume yields the absorption due to the water alone. In order to accommodate variations in temperature and pressure, and to make the system more robust (e.g. for ship deck usage), it is desirable to employ stainless steel vessels. However, it was found that the quality of the data was greatly improved when pyrex glass spheres were used. The stainless steel spheres were manufactured by welding together mechanically spun hemispheres. The linear frequency dependence characteristic of acoustic absorption in solids was observed (in contrast to the quadratic frequency dependence of acoustic absorption in water), and the acoustic absorption was found to depend strongly on the thermal history of the steel

  17. Characteristics of water absorption of beans

    OpenAIRE

    上中, 登紀子; 森, 孝夫; 豊沢, 功; Tokiko, Uenaka; Takao, Mori; Isao, Toyosawa

    2001-01-01

    Characteristics of water absorption of soybean, azuki bean and kidney beans (cv. Toramame and Taishokintoki) were investigated. The way of water absorption of soybean was different from that of other beans, because soybeans absorbed water from whole surface of seed coat immediately after the immersion. Azuki beans absorbed extremely slowly water from only strophiole, and then the water absorption in other tissue was induced by a certain amount of water absorption playing a role of trigger. Th...

  18. Atomic absorption spectrophotometry in perspective

    International Nuclear Information System (INIS)

    Soffiantini, V.

    1981-01-01

    Atomic absorption spectrophotometry is essentially an analytical technique used for quantitative trace metal analysis in a variety of materials. The speed and specificity of the technique is its greatest advantage over other analytical techniques. What atomic absorption spectrophotometry can and cannot do and its advantages and disadvantages are discussed, a summary of operating instructions are given, as well as a summary of analytical interferences. The applications of atomic absorption spectrophotometry are also shortly discussed

  19. Revisiting Absorptive Capacity

    DEFF Research Database (Denmark)

    de Araújo, Ana Luiza Lara; Ulhøi, John Parm; Lettl, Christopher

    Absorptive capacity has mostly been perceived as a 'passive' outcome of R&D investments. Recently, however, a growing interest into its 'proactive' potentials has emerged. This paper taps into this development and proposes a dynamic model for conceptualizing the determinants of the complementary...... learning processes of absorptive capacity, which comprise combinative and adaptive capabilities. Drawing on survey data (n=169), the study concludes that combinative capabilities primarily enhance transformative and exploratory learning processes, while adaptive capabilities strengthen all three learning...

  20. Absorption and Metabolism of Xanthophylls

    Directory of Open Access Journals (Sweden)

    Eiichi Kotake-Nara

    2011-06-01

    Full Text Available Dietary carotenoids, especially xanthophylls, have attracted significant attention because of their characteristic biological activities, including anti-allergic, anti-cancer, and anti-obese actions. Although no less than forty carotenoids are ingested under usual dietary habits, only six carotenoids and their metabolites have been found in human tissues, suggesting selectivity in the intestinal absorption of carotenoids. Recently, facilitated diffusion in addition to simple diffusion has been reported to mediate the intestinal absorption of carotenoids in mammals. The selective absorption of carotenoids may be caused by uptake to the intestinal epithelia by the facilitated diffusion and an unknown excretion to intestinal lumen. It is well known that β-carotene can be metabolized to vitamin A after intestinal absorption of carotenoids, but little is known about the metabolic transformation of non provitamin A xanthophylls. The enzymatic oxidation of the secondary hydroxyl group leading to keto-carotenoids would occur as a common pathway of xanthophyll metabolism in mammals. This paper reviews the absorption and metabolism of xanthophylls by introducing recent advances in this field.

  1. Absorption and metabolism of xanthophylls.

    Science.gov (United States)

    Kotake-Nara, Eiichi; Nagao, Akihiko

    2011-01-01

    Dietary carotenoids, especially xanthophylls, have attracted significant attention because of their characteristic biological activities, including anti-allergic, anti-cancer, and anti-obese actions. Although no less than forty carotenoids are ingested under usual dietary habits, only six carotenoids and their metabolites have been found in human tissues, suggesting selectivity in the intestinal absorption of carotenoids. Recently, facilitated diffusion in addition to simple diffusion has been reported to mediate the intestinal absorption of carotenoids in mammals. The selective absorption of carotenoids may be caused by uptake to the intestinal epithelia by the facilitated diffusion and an unknown excretion to intestinal lumen. It is well known that β-carotene can be metabolized to vitamin A after intestinal absorption of carotenoids, but little is known about the metabolic transformation of non provitamin A xanthophylls. The enzymatic oxidation of the secondary hydroxyl group leading to keto-carotenoids would occur as a common pathway of xanthophyll metabolism in mammals. This paper reviews the absorption and metabolism of xanthophylls by introducing recent advances in this field.

  2. Nasal Absorption of Macromolecules from Powder Formulations and Effects of Sodium Carboxymethyl Cellulose on Their Absorption.

    Directory of Open Access Journals (Sweden)

    Akiko Tanaka

    Full Text Available The nasal absorption of macromolecules from powder formulations and the effect of sodium carboxymethyl cellulose (CMC-Na as a pharmaceutical excipient on their absorption were studied. Model macromolecules were fluorescein isothiocyanate-labeled dextran (average molecular weight of 4.4kDa, FD4 and insulin. The plasma concentration of FD4 after application of the powder containing 50% starch (control was higher than that after application of the solution, and the absorption from 50% starch powder was enhanced by the substitution of starch with CMC-Na. The fractional absorption of FD4 after administration of the CMC-Na powder formulation was 30% and 40% higher than that after administration from the solution and the starch powder, respectively. The nasal absorption of insulin from the powder and the effect of CMC-Na were similar with those of FD4. The effective absorption of FD4 and insulin after application of powder with CMC-Na could be due to the increase in the nasal residence of FD4 and insulin. No damage in the nasal mucosa or dysfunction of the mucociliary clearance was observed after application of the drug powder and CMC-Na. The present findings indicate that nasal delivery of powder formulations with the addition of CMC-Na as an excipient is a promising approach for improving the nasal absorption of macromolecules.

  3. Modulation of intestinal absorption of calcium

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, P; Dupuis, Y [Ecole Pratique des Hautes Etudes, 75 - Paris (France); Paris-11 Univ., 92 - Chatenay-Malabry (France))

    1975-01-01

    Absorption of ingested calcium (2ml of a 10mM CaCl/sub 2/ solution + /sup 45/Ca) by the adult rat was shown to be facilitated by the simultaneous ingestion of an active carbohydrate, L-arabinose. As the carbohydrate concentration is increased from 10 to 200mM, the absorption of calcium is maximised at a level corresponding to about twice the control absorption level. A similar doubling of calcium absorption is obtained when a 100mM concentration of any one of a number of other carbohydrates is ingested simultaneously with a 10mM CaCl/sub 2/ solution. Conversely, the simultaneous ingestion of increasing doses (10 to 100mM) of phosphate (NaH/sub 2/PO/sub 4/) with a 10mM CaCl/sub 2/ solution results in decreased /sup 45/Ca absorption and retention by the adult rat. The maximum inhibition of calcium absorption by phosphate is independent of the concentration of the ingested calcium solution (from 5 to 50mM CaCl/sub 2/). The simultaneous ingestion of CaCl/sub 2/ (10mM) with lactose and sodium phosphate (50 and 10mM respectively) shows that the activation effect of lactose upon /sup 45/Ca absorption may be partly dissimulated by the presence of phosphate. These various observations indicate that, within a large concentration range (2 to 50mM CaCl/sub 2/) calcium absorption appears to be a precisely modulated diffusion process. Calcium absorption varies (between minimum and maximum levels) as a function of the state of saturation by the activators (carbohydrates) and inhibitors (phosphate) of the calcium transport system.

  4. Absorption lines, Faraday rotation, and magnetic field estimates for QSO absorption-line clouds

    International Nuclear Information System (INIS)

    Kronberg, P.P.; Perry, J.J.

    1982-01-01

    We have estimated the extragalactic component of Faraday rotation for a sample of 37 QSOs for which there is good absorption line data, which we have also analyzed. Statistical evidence is presented which suggests that we have isolated a component of Faraday rotation which is occurring in the absorption clouds of some QSOs

  5. Zeeman atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Loos-Vollebregt, M.T.C. de.

    1980-01-01

    A new method of background correction in atomic absorption spectroscopy has recently been introduced, based on the Zeeman splitting of spectral lines in a magnetic field. A theoretical analysis of the background correction capability observed in such instruments is presented. A Zeeman atomic absorption spectrometer utilizing a 50 Hz sine wave modulated magnetic field is described. (Auth.)

  6. Spectral interferences in atomic absorption spectrometry, (5)

    International Nuclear Information System (INIS)

    Daidoji, Hidehiro

    1979-01-01

    Spectral interferences were observed in trace element analysis of concentrated solutions by atomic absorption spectrometry. Molecular absorption and emission spectra for strontium chloride and nitrate, barium chloride and nitrate containing 12 mg/ml of metal ion in airacetylene flame were measured in the wavelength range from 200 to 700 nm. The absorption and emission spectra of SrO were centered near 364.6 nm. The absorption spectra of SrOH around 606.0, 671.0 and 682.0 nm were very strong. And, emission spectrum of BaOH in the wavelength range from 480 to 550 nm was stronger. But, the absorption of this band spectrum was very weak. In the wavelength range from 200 to 400 nm, some unknown bands of absorption were observed for strontium and barium. Absorption spectra of SrCl and BaCl were observed in the argon-hydrogen flame. Also, in the carbon tube atomizer, the absorption spectra of SrCl and BaCl were detected clearly in the wavelength range from 185 to 400 nm. (author)

  7. X-ray absorption in atomic potassium

    International Nuclear Information System (INIS)

    Gomilsek, Jana Padeznik; Kodre, Alojz; Arcon, Iztok; Nemanic, Vincenc

    2008-01-01

    A new high-temperature absorption cell for potassium vapor is described. X-ray absorption coefficient of atomic potassium is determined in the energy interval of 600 eV above the K edge where thresholds for simultaneous excitations of 1s and outer electrons, down to [1s2p] excitation, appear. The result represents also the atomic absorption background for XAFS (X-ray absorption fine structure) structure analysis. The K ionization energy in the potassium vapor is determined and compared with theoretical data and with the value for the metal

  8. Gastrointestinal absorption of Np in rats

    International Nuclear Information System (INIS)

    Wirth, R.; Volf, V.

    1985-01-01

    The effect of Np mass and the acidity of the administered Np solutions as well as the age, sex and nutritional status of the animals injected or gavaged with 239Np or 237Np were determined. The latter factor proved to be dominant for absorption of Np from the gut. Thus in fasting weanling and young adult male rats, the absorption of 239Np was sixfold higher (0.18% and 0.12%, respectively) than in fed ones (0.03% and 0.02%, respectively). Absorption by fasted adult females was 0.05% of the administered 239Np, about half of that of adult males. Raising the Np-mass gavaged to fasted female rats to 1 and 10 mg 237Np/kg resulted in an absorption of 0.23% and 0.26%, respectively. Thus, an increased absorption of Np in adult rats seems to be expected only if a large mass is ingested. No dependence of the absorption of Np on nitric acid concentration was found. The data obtained after oral administration of 238Pu and 239Np to adult rats suggest that the f1 factor recommended by the ICRP for fractional absorption of soluble Np compounds from the gut should be decreased, whereas the f1 factor for soluble Pu compounds should be raised

  9. Threshold nonlinear absorption in Zeeman transitions

    International Nuclear Information System (INIS)

    Narayanan, Andal; Hazra, Abheera; Sandhya, S N

    2010-01-01

    We experimentally study the absorption spectroscopy from a collection of gaseous 87 Rb atoms at room temperature irradiated with three fields. Two of these fields are in a pump-probe saturation absorption configuration. The third field co-propagates with the pump field. The three fields address Zeeman degenerate transitions between hyperfine levels 5S 1/2 , F = 1 and 5P 3/2 , F = 0, F = 1 around the D2 line. We find a sub-natural absorption resonance in the counter-propagating probe field for equal detunings of all three fields. This absorption arises in conjunction with the appearance of increased transmission due to electro-magnetically induced transparency in the co-propagating fields. The novel feature of this absorption is its onset only for the blue of 5P 3/2 , F = 0, as the laser frequency is scanned through the excited states 5P 3/2 , F = 0, F = 1 and F = 2. The absorption rapidly rises to near maximum values within a narrow band of frequency near 5P 3/2 , F = 0. Our experimental results are compared with a dressed atom model. We find the threshold absorption to be a result of coherent interaction between the dressed states of our system.

  10. Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2014-01-01

    into random incidence absorption coefficients for porous absorbers are investigated. Two optimization-based conversion methods are suggested: the surface impedance estimation for locally reacting absorbers and the flow resistivity estimation for extendedly reacting absorbers. The suggested conversion methods...

  11. Glucose absorption in acute peritoneal dialysis.

    Science.gov (United States)

    Podel, J; Hodelin-Wetzel, R; Saha, D C; Burns, G

    2000-04-01

    During acute peritoneal dialysis (APD), it is known that glucose found in the dialysate solution contributes to the provision of significant calories. It has been well documented in continuous ambulatory peritoneal dialysis (CAPD) that glucose absorption occurs. In APD, however, it remains unclear how much glucose absorption actually does occur. Therefore, the purpose of this study was to determine whether it is appropriate to use the formula used to calculate glucose absorption in CAPD (Grodstein et al) among patients undergoing APD. Actual measurements of glucose absorption (Method I) were calculated in 9 patients undergoing APD treatment for >24 hours who were admitted to the intensive care unit. Glucose absorption using the Grodstein et al formula (Method II) was also determined and compared with the results of actual measurements. The data was then further analyzed based on the factors that influence glucose absorption, specifically dwell time and concentration. The mean total amount of glucose absorbed was 43% +/- 15%. However, when dwell time and concentration were further examined, significant differences were noted. Method I showed a cumulative increase over time. Method II showed that absorption was fixed. This suggests that with the variation in dwell time commonly seen in the acute care setting, the use of Method II may not be accurate. In each of the 2 methods, a significant difference in glucose absorption was noted when comparing the use of 1.5% and 4.25% dialysate concentrations. The established formula designed for CAPD should not be used for calculating glucose absorption in patients receiving APD because variation in dwell time and concentration should be taken into account. Because of the time constraints and staffing required to calculate each exchange individually, combined with the results of the study, we recommend the use of the percentage estimate of 40% to 50%.

  12. Reproducibility of The Random Incidence Absorption Coefficient Converted From the Sabine Absorption Coefficient

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Chang, Ji-ho

    2015-01-01

    largely depending on the test room. Several conversion methods for porous absorbers from the Sabine absorption coefficient to the random incidence absorption coefficient were suggested by considering the finite size of a test specimen and non-uniformly incident energy onto the specimen, which turned out...... resistivity optimization outperforms the surface impedance optimization in terms of the reproducibility....

  13. Aerosol Absorption Measurements in MILAGRO.

    Science.gov (United States)

    Gaffney, J. S.; Marley, N. A.; Arnott, W. P.; Paredes-Miranda, L.; Barnard, J. C.

    2007-12-01

    During the month of March 2006, a number of instruments were used to determine the absorption characteristics of aerosols found in the Mexico City Megacity and nearby Valley of Mexico. These measurements were taken as part of the Department of Energy's Megacity Aerosol Experiment - Mexico City (MAX-Mex) that was carried out in collaboration with the Megacity Interactions: Local and Global Research Observations (MILAGRO) campaign. MILAGRO was a joint effort between the DOE, NSF, NASA, and Mexican agencies aimed at understanding the impacts of a megacity on the urban and regional scale. A super-site was operated at the Instituto Mexicano de Petroleo in Mexico City (designated T-0) and at the Universidad Technologica de Tecamac (designated T-1) that was located about 35 km to the north east of the T-0 site in the State of Mexico. A third site was located at a private rancho in the State of Hidalgo approximately another 35 km to the northeast (designated T-2). Aerosol absorption measurements were taken in real time using a number of instruments at the T-0 and T-1 sites. These included a seven wavelength aethalometer, a multi-angle absorption photometer (MAAP), and a photo-acoustic spectrometer. Aerosol absorption was also derived from spectral radiometers including a multi-filter rotating band spectral radiometer (MFRSR). The results clearly indicate that there is significant aerosol absorption by the aerosols in the Mexico City megacity region. The absorption can lead to single scattering albedo reduction leading to values below 0.5 under some circumstances. The absorption is also found to deviate from that expected for a "well-behaved" soot anticipated from diesel engine emissions, i.e. from a simple 1/lambda wavelength dependence for absorption. Indeed, enhanced absorption is seen in the region of 300-450 nm in many cases, particularly in the afternoon periods indicating that secondary organic aerosols are contributing to the aerosol absorption. This is likely due

  14. Converting Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface...... coefficients to random incidence absorption coefficients are proposed. The overestimations of the Sabine absorption coefficient are investigated theoretically based on Miki's model for porous absorbers backed by a rigid wall or an air cavity, resulting in conversion factors. Additionally, three optimizations...... impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model...

  15. Field Measurements of Water Continuum and Water Dimer Absorption by Active Long Path Differential Optical Absorption Spectroscopy (DOAS)

    OpenAIRE

    Lotter, Andreas

    2006-01-01

    Water vapor plays an important role in Earth's radiative budget since water molecules strongly absorb the incoming solar shortwave and the outgoing thermal infrared radiation. Superimposed on the water monomer absorption, a water continuum absorption has long been recognized, but its true nature still remains controversial. On the one hand, this absorption is explained by a deformation of the line shape of the water monomer absorption lines as a consequence of a molecular collision. One the o...

  16. Optical absorption measurement system

    International Nuclear Information System (INIS)

    Draggoo, V.G.; Morton, R.G.; Sawicki, R.H.; Bissinger, H.D.

    1989-01-01

    This patent describes a non-intrusive method for measuring the temperature rise of optical elements under high laser power optical loading to determine the absorption coefficient. The method comprises irradiating the optical element with a high average power laser beam, viewing the optical element with an infrared camera to determine the temperature across the optical element and calculating the absorption of the optical element from the temperature

  17. Iron, lead, and cobalt absorption: similarities and dissimilarities

    International Nuclear Information System (INIS)

    Barton, J.C.; Conrad, M.E.; Holland, R.

    1981-01-01

    Using isolated intestinal segments in rats, the absorption of iron, lead, and cobalt was increased in iron deficiency and decreased in iron loading. Similarly, the absorption of these metals was decreased in transfusional erythocytosis, after intravenous iron injection and after parenteral endotoxin injection. Acute bleeding or abbreviated intervals of dietary iron deprivation resulted in increased iron absorption from isolated intestinal segments and in intact animals, while the absorption of lead and cobalt was unaffected. These results suggest that the specificity of the mucosal metal absorptive mechanism is either selectively enhanced for iron absorption by phlebotomy or brief periods of dietary iron deprivation, or that two or more mucosal pathways for iron absorption may exist

  18. On pair-absorption in intrinsic vapours

    International Nuclear Information System (INIS)

    Hotop, R.; Niemax, K.; Schlueter, D.

    1982-01-01

    The bound-state pair-absorption bands Cs(6 2 S 1 sub(/) 2 ) + Cs(6 2 S 1 sub(/) 2 ) + hν → Cs(5 2 D 5 sub(/) 2 sub(,) 3 sub(/) 2 ) + Cs(6 2 P 1 sub(/) 2 ) and the K-K continuum-state pair-absorptions in the wavelength region 2.350 <= lambda <= 2.850 Angstroem have been investigated experimentally. In the case of the bound-state pair-absorption bands a theoretical approach for the absorption cross section at the band centre is given which is in good agreement with the experimental observation. Differences between our and the theoretical formulas given by the Stanford group are discussed. (orig.)

  19. Compression-absorption (resorption) refrigerating machinery. Modeling of reactors; Machine frigorifique a compression-absorption (resorption). Modelisation des reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    Lottin, O; Feidt, M; Benelmir, R [LEMTA-UHP Nancy-1, 54 - Vandoeuvre-les-Nancy (France)

    1998-12-31

    This paper is a series of transparencies presenting a comparative study of the thermal performances of different types of refrigerating machineries: di-thermal with vapor compression, tri-thermal with moto-compressor, with ejector, with free piston, adsorption-type, resorption-type, absorption-type, compression-absorption-type. A prototype of ammonia-water compression-absorption heat pump is presented and modeled. (J.S.)

  20. Compression-absorption (resorption) refrigerating machinery. Modeling of reactors; Machine frigorifique a compression-absorption (resorption). Modelisation des reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    Lottin, O.; Feidt, M.; Benelmir, R. [LEMTA-UHP Nancy-1, 54 - Vandoeuvre-les-Nancy (France)

    1997-12-31

    This paper is a series of transparencies presenting a comparative study of the thermal performances of different types of refrigerating machineries: di-thermal with vapor compression, tri-thermal with moto-compressor, with ejector, with free piston, adsorption-type, resorption-type, absorption-type, compression-absorption-type. A prototype of ammonia-water compression-absorption heat pump is presented and modeled. (J.S.)

  1. Iron absorption after antrectomy with gastroduodenostomy

    International Nuclear Information System (INIS)

    Magnusson, B.E.O.

    1976-01-01

    Haematological values were studied in 177 unselected patients 3-6 years after antrectomy with gastroduodenostomy. The majority (76%) had been operated upon for duodenal ulcer, 20% for gastric ulcer and the remaining patients had had both a duodenal and a gastric ulcer before the operation. In 65 patients a vagotomy had been added to the resection. 10% of the males and 15% of the females had a haemoglobin concentration below 13.0 or 12.0 g/100 ml, respectively. The corresponding frequencies for iron defifiency, defined as absence or only traces of haemosiderin in bone marrow smears, were 7% and 15%. The absorption of a small test dose of inorganic iron (0.56 mg Fe ++ as ferrous ascorbate) was studied in all the antrectomized patients. The absorption was also investigated in normal men and in patients who had had a Billroth II partial gastrectomy. No malabsorption of inorganic iron could be found in any of the groups. An inverse relationship between iron absorption and the grading of haemosiderin in bone marrow smears was found in normal subjects as well as in operated patients. Thus, an adequate increase of the absorption of ferrous iron was found even in operated patients with iron deficiency. Gastric acid secretion, measured as the peak acid output (PAO) after stimulation, was determined in all antrectomized patients. In patients having the same grading of haemosiderin (grade II) a slight but significant positive correlation was found between PAO and the absorption from the test dose (Fe ++ ). The absorption of food iron from a composite meal and the absorption from an iron salt (3.0 mg Fe ++ as ferrous ascorbate) was studied in 4 different groups: 1) normal males, 2) non-operated patients with peptic ulcer, 3) antrectomized patients with gastroduodenostomy and 4) patients operated upon with Billroth II partial gastrectomy. The range and mean absorption values from the test dose of inorganic iron were about the same in all groups. The absorption of food iron

  2. Lithium absorption by the rabbit gall-bladder

    DEFF Research Database (Denmark)

    Hansen, C P; Holstein-Rathlou, N H; Skøtt, O

    1991-01-01

    Lithium (Li+) absorption across the low-resistance epithelium of the rabbit gall-bladder was studied in order to elucidate possible routes and mechanisms of Li+ transfer. Li+ at a concentration of 0.4 mM in both mucosal and serosal media did not affect isosmotic mucosa-to-serosa fluid absorption...... was elicited from the mucosal side and was not accounted for by compensatory Li+ absorption; water and Na+ absorption rates decreased nearly in parallel. The effects of 0.4 mM amiloride and of substitution with 20 mM Li+ were only partly additive. It is concluded that Li+ absorption in the rabbit gall...

  3. Sublinear absorption in OCS gas

    International Nuclear Information System (INIS)

    Bogani, F.; Querzoli, R.; Ernst, K.

    1988-01-01

    Sublinear absorption in OCS gas has been experimentally studied in detail by means of an optoacustic technique and transmission measurements. The best fit of the results is obtained by a phenomenological model, that considers the process as the sum of one-and two-photon absorptions

  4. Lactulose stimulates calcium absorption in postmenopausal women

    NARCIS (Netherlands)

    Heuvel, E.G.H.M. van den; Muijs, T.; Dokkum, W. van; Schaafsma, G.

    1999-01-01

    Animal studies have indicated that calcium absorption is increased by lactulose, a synthetic disaccharide. Therefore, the influence of lactulose on calcium absorption was measured in postmenopausal women who may benefit from the possible enhancing effect of lactulose on calcium absorption. Twelve

  5. 51Cr-ethylenediaminetetraacetic acid absorption test

    International Nuclear Information System (INIS)

    Aabakken, L.

    1989-01-01

    The 51 Cr-ethylenediaminetetraacetic acid (EDTA) absorption test was evaluated in 83 healthy, male volunteers. Base-line 24 h excretion after peroral administration ranged from 0.88% to 7.96%, with a higher median absorption than reported by most authors (2.45%). However, the reproducibility and stability of the method and the reproducibility of the results were satisfactory. Urinary excretion after intraduodenal installation (n=18) was comparable to that seen after peroral test dose administration, indicating a limited significance of gastric 51 Cr-EDTA absorption under normal conditions. In 16 subjects a single intake of alcohol immediately before the test gave a modest and short-lasting increase in 51 Cr-EDTA absorption. No correlation was seen to body mass index, creatinine clearance, urinary volume, or small-bowel transit time, possibly reducing the number of confounding factors in the evaluation of absorption data. A small but significant negative correlation was, however, found to body surface area and age

  6. Water absorption characteristic of interlocking compressed earth brick units

    Science.gov (United States)

    Bakar, B. H. Abu; Saari, S.; Surip, N. A.

    2017-10-01

    This study aims to investigate the water absorption characteristic of interlocking compressed earth brick (ICEB) units. Apart from compressive strength, water absorption is an important property in masonry. This property can affect the quality of the brick itself and the bond strength between the brick and mortar in masonry structures and can result in reducing its strength properties. The units were tested for 24 h water absorption and 5 h boiling water absorption. A total of 170 ICEB units from four ICEB types underwent both tests. For the 24 h water absorption, the ICEB units were dried in the oven for 24 h and then cooled before being weighed. Thereafter, each brick was immersed in water for 24 h and weighed. The same specimens used for the 24 h water absorption test were re-used for the 5 h boiling water absorption test. After completing the 24 h water absorption test, the brick was boiled for 5-hours and weighed. The highest water absorption for the ICEBs in the 24-hour water absorption and 5 h boiling water absorption tests are 15.09% and 17.18%, respectively. The half brick has the highest water absorption (15.87%), whereas the beam brick has the lowest (13.20%). The water absorption of an ICEB unit is higher than that of normal bricks, although the water absorption of the former remains below the maximum rate of the brick water absorption (21%).

  7. Absorptive capacity and smart companies

    Directory of Open Access Journals (Sweden)

    Patricia Moro González

    2014-12-01

    Full Text Available Purpose: The current competitive environment is substantially modifying the organizations’ learning processes due to a global increase of available information allowing this to be transformed into knowledge. This opportunity has been exploited since the nineties by the tools of “Business Analytics” and “Business Intelligence” but, nevertheless, being integrated in the study of new organizational capacities engaged in the process of creating intelligence inside organizations is still an outstanding task. The review of the concept of absorptive capacity and a detailed study from the perspective of this new reality will be the main objective of study of this paper.Design/methodology/approach: By comparing classical absorptive capacity and absorptive capacity from the point of view of information management tools in each one of the three stages of the organizational learning cycle, some gaps of the former are overcome/fulfilled. The academic/bibliographical references provided in this paper have been obtained from ISI web of knowledge, Scopus and Dialnet data bases, supporting the state of affairs on absorptive capacity and thereafter filtering by "Business Intelligence" and "Business Analytics". Specialized websites and Business Schools` Publications there have also been included, crowning the content on information management tools used that are currently used in the strategic consulting.Findings: Our contribution to the literature is the development of "smart absorptive capacity". This is a new capacity emerging from the reformulation of the classical concept of absorptive capacity wherein some aspects of its definition that might have been omitted are emphasized. The result of this new approach is the creation of a new Theoretical Model of Organizational Intelligence, which aims to explain, within the framework of the Resources and Capabilities Theory, the competitive advantage achieved by the so-called smart companies

  8. Enriching Absorptive Capacity Through Social Interaction

    DEFF Research Database (Denmark)

    Hotho, Jasper Jaap; Becker-Ritterspach, Florian; Saka-Helmhout, Ayse

    their organization’s capacity to put new knowledge to use. To address this shortcoming we conduct an in-depth comparative case study of a headquarters-initiated knowledge transfer initiative at two subsidiaries of the same MNE. The findings demonstrate that social interaction is a key requirement for subsidiary....... These insights contribute to the absorptive capacity literature by demonstrating the scale and scope of social interaction as the key link between individual- and organizational-level absorptive capacity.......Absorptive capacity is frequently highlighted as a key determinant of knowledge transfer within MNEs. But how individual behaviour translates to absorptive capacity at the subsidiary level, and exactly how this is contingent on subsidiaries’ social context, remains under-addressed. This not only...

  9. Enriching Absorptive Capacity through Social Interaction

    DEFF Research Database (Denmark)

    Hotho, Jasper J.; Saka-Helmhout, Ayse; Becker-Ritterspach, Florian

    2012-01-01

    their organization's capacity to put new knowledge to use. To address this shortcoming we conduct an in-depth comparative case study of a headquarters-initiated knowledge transfer at two subsidiaries of the same multinational enterprise. The findings demonstrate that social interaction is a prerequisite...... or constraining local interaction patterns. These insights contribute to the absorptive capacity literature by demonstrating the scale and scope of social interaction as a key link between individual- and organizational-level absorptive capacity.......Absorptive capacity is frequently highlighted as a key determinant of knowledge transfer within multinational enterprises. But how individual behaviour translates into absorptive capacity at the subsidiary level, and how this is contingent on subsidiaries' social context, remains under...

  10. Absorption Spectra of Gold Nanoparticle Suspensions

    Science.gov (United States)

    Anan'eva, M. V.; Nurmukhametov, D. R.; Zverev, A. S.; Nelyubina, N. V.; Zvekov, A. A.; Russakov, D. M.; Kalenskii, A. V.; Eremenko, A. N.

    2018-02-01

    Three gold nanoparticle suspensions are obtained, and mean radii in distributions - (6.1 ± 0.2), (11.9 ± 0.3), and (17.3 ± 0.7) nm - are determined by the transmission electron microscopy method. The optical absorption spectra of suspensions are obtained and studied. Calculation of spectral dependences of the absorption index of suspensions at values of the gold complex refractive index taken from the literature showed a significant deviation of experimental and calculated data in the region of 450-800 nm. Spectral dependences of the absorption of suspensions are simulated within the framework of the Mie-Drude theory taking into account the interband absorption in the form of an additional term in the imaginary part of the dielectric permittivity of the Gaussian type. It is shown that to quantify the spectral dependences in the region of the plasmon absorption band of nanoparticles, correction of the parameters of the interband absorption is necessary in addition to the increase of the relaxation parameter of the Drude theory. Spectral dependences of the dielectric permittivity of gold in nanodimensional state are refined from the solution of the inverse problem. The results of the present work are important for predicting the special features of operation of photonic devices and optical detonators based on gold nanoparticles.

  11. Wave energy absorption by ducks

    OpenAIRE

    Kurniawan, Adi

    2017-01-01

    We study the absorption of wave energy by a single and multiple cam-shaped bodies referred to as ducks. Numerical models are developed under the assumptions of linear theory. We consider wave absorption by a single duck as well as by two lines of ducks meeting at an angle.

  12. Wave energy absorption by ducks

    DEFF Research Database (Denmark)

    Kurniawan, Adi

    2018-01-01

    We study the absorption of wave energy by a single and multiple cam-shaped bodies referred to as ducks. Numerical models are developed under the assumptions of linear theory. We consider wave absorption by a single duck as well as by two lines of ducks meeting at an angle....

  13. Water absorption in brick masonry

    NARCIS (Netherlands)

    Brocken, H.J.P.; Smolders, H.R.

    1996-01-01

    The water absorption in brick, mortar that was cured separately, and masonry samples was studied using NMR. Models of the moisture transport are usually formulated on the basis of a diffusion equation. In the case of water absorption in separate brick and mortar samples, the moisture diffusivity in

  14. The effect of volatility on percutaneous absorption.

    Science.gov (United States)

    Rouse, Nicole C; Maibach, Howard I

    2016-01-01

    Topically applied chemicals may volatilize, or evaporate, from skin leaving behind a chemical residue with new percutaneous absorptive capabilities. Understanding volatilization of topical medications, such as sunscreens, fragrances, insect repellants, cosmetics and other commonly applied topicals may have implications for their safety and efficacy. A systematic review of English language articles from 1979 to 2014 was performed using key search terms. Articles were evaluated to assess the relationship between volatility and percutaneous absorption. A total of 12 articles were selected and reviewed. Key findings were that absorption is enhanced when coupled with a volatile substance, occlusion prevents evaporation and increases absorption, high ventilation increases volatilization and reduces absorption, and pH of skin has an affect on a chemical's volatility. The articles also brought to light that different methods may have an affect on volatility: different body regions; in vivo vs. in vitro; human vs. Data suggest that volatility is crucial for determining safety and efficacy of cutaneous exposures and therapies. Few articles have been documented reporting evaporation in the context of percutaneous absorption, and of those published, great variability exists in methods. Further investigation of volatility is needed to properly evaluate its role in percutaneous absorption.

  15. Aerosol Angstrom Absorption Coefficient Comparisons during MILAGRO.

    Science.gov (United States)

    Marley, N. A.; Marchany-Rivera, A.; Kelley, K. L.; Mangu, A.; Gaffney, J. S.

    2007-12-01

    Measurements of aerosol absorption were obtained as part of the MAX-Mex component of the MILAGRO field campaign at site T0 (Instituto Mexicano de Petroleo in Mexico City) by using a 7-channel aethalometer (Thermo- Anderson) during the month of March, 2006. The absorption measurements obtained in the field at 370, 470, 520, 590, 660, 880, and 950 nm were used to determine the aerosol Angstrom absorption exponents by linear regression. Since, unlike other absorbing aerosol species (e.g. humic like substances, nitrated PAHs), black carbon absorption is relatively constant from the ultraviolet to the infrared with an Angstrom absorption exponent of -1 (1), a comparison of the Angstrom exponents can indicate the presence of aerosol components with an enhanced UV absorption over that expected from BC content alone. The Angstrom exponents determined from the aerosol absorption measurements obtained in the field varied from - 0.7 to - 1.3 during the study and was generally lower in the afternoon than the morning hours, indicating an increase in secondary aerosol formation and photochemically generated UV absorbing species in the afternoon. Twelve-hour integrated samples of fine atmospheric aerosols (Petroleo (IMP) and CENICA.

  16. Photoionization-driven Absorption-line Variability in Balmer Absorption Line Quasar LBQS 1206+1052

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Luming; Zhou, Hongyan; Ji, Tuo; Jiang, Peng; Liu, Bo; Pan, Xiang; Shi, Xiheng; Zhang, Shaohua [Polar Research Institute of China, 451 Jinqiao Road, Shanghai (China); Liu, Wenjuan; Wang, Jianguo [Yunnan Observatories, Chinese Academy of Sciences, Kunming, Yunnan (China); Wang, Tinggui; Yang, Chenwei [Department of Astronomy, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui (China); Miller, Lauren P., E-mail: lmsun@mail.ustc.edu.cn [Lehigh University, 27 Memorial Drive West, Bethlehem, PA 18015 (United States)

    2017-04-01

    In this paper we present an analysis of absorption-line variability in mini-BAL quasar LBQS 1206+1052. The Sloan Digital Sky Survey spectrum demonstrates that the absorption troughs can be divided into two components of blueshift velocities of ∼700 and ∼1400 km s{sup −1} relative to the quasar rest frame. The former component shows rare Balmer absorption, which is an indicator of high-density absorbing gas; thus, the quasar is worth follow-up spectroscopic observations. Our follow-up optical and near-infrared spectra using MMT, YFOSC, TSpec, and DBSP reveal that the strengths of the absorption lines vary for both components, while the velocities do not change. We reproduce all of the spectral data by assuming that only the ionization state of the absorbing gas is variable and that all other physical properties are invariable. The variation of ionization is consistent with the variation of optical continuum from the V -band light curve. Additionally, we cannot interpret the data by assuming that the variability is due to a movement of the absorbing gas. Therefore, our analysis strongly indicates that the absorption-line variability in LBQS 1206+1052 is photoionization driven. As shown from photoionization simulations, the absorbing gas with blueshift velocity of ∼700 km s{sup −1} has a density in the range of 10{sup 9} to 10{sup 10} cm{sup −3} and a distance of ∼1 pc, and the gas with blueshift velocity of ∼1400 km s{sup −1} has a density of 10{sup 3} cm{sup −3} and a distance of ∼1 kpc.

  17. Uniform semiclassical approximation for absorptive scattering systems

    International Nuclear Information System (INIS)

    Hussein, M.S.; Pato, M.P.

    1987-07-01

    The uniform semiclassical approximation of the elastic scattering amplitude is generalized to absorptive systems. An integral equation is derived which connects the absorption modified amplitude to the absorption free one. Division of the amplitude into a diffractive and refractive components is then made possible. (Author) [pt

  18. Absorption factor for cylindrical samples

    International Nuclear Information System (INIS)

    Sears, V.F.

    1984-01-01

    The absorption factor for the scattering of X-rays or neutrons in cylindrical samples is calculated by numerical integration for the case in which the absorption coefficients of the incident and scattered beams are not equal. An extensive table of values having an absolute accuracy of 10 -4 is given in a companion report [Sears (1983). Atomic Energy of Canada Limited, Report No. AECL-8176]. In the present paper an asymptotic expression is derived for the absorption factor which can be used with an error of less than 10 -3 for most cases of interest in both neutron inelastic scattering and neutron diffraction in crystals. (Auth.)

  19. Importance of the green color, absorption gradient, and spectral absorption of chloroplasts for the radiative energy balance of leaves.

    Science.gov (United States)

    Kume, Atsushi

    2017-05-01

    Terrestrial green plants absorb photosynthetically active radiation (PAR; 400-700 nm) but do not absorb photons evenly across the PAR waveband. The spectral absorbance of photosystems and chloroplasts is lowest for green light, which occurs within the highest irradiance waveband of direct solar radiation. We demonstrate a close relationship between this phenomenon and the safe and efficient utilization of direct solar radiation in simple biophysiological models. The effects of spectral absorptance on the photon and irradiance absorption processes are evaluated using the spectra of direct and diffuse solar radiation. The radiation absorption of a leaf arises as a consequence of the absorption of chloroplasts. The photon absorption of chloroplasts is strongly dependent on the distribution of pigment concentrations and their absorbance spectra. While chloroplast movements in response to light are important mechanisms controlling PAR absorption, they are not effective for green light because chloroplasts have the lowest spectral absorptance in the waveband. With the development of palisade tissue, the incident photons per total palisade cell surface area and the absorbed photons per chloroplast decrease. The spectral absorbance of carotenoids is effective in eliminating shortwave PAR (solar radiation. However, most of the near infrared radiation is unabsorbed and heat stress is greatly reduced. The incident solar radiation is too strong to be utilized for photosynthesis under the current CO 2 concentration in the terrestrial environment. Therefore, the photon absorption of a whole leaf is efficiently regulated by photosynthetic pigments with low spectral absorptance in the highest irradiance waveband and through a combination of pigment density distribution and leaf anatomical structures.

  20. Dissociative absorption: An empirically unique, clinically relevant, dissociative factor.

    Science.gov (United States)

    Soffer-Dudek, Nirit; Lassri, Dana; Soffer-Dudek, Nir; Shahar, Golan

    2015-11-01

    Research of dissociative absorption has raised two questions: (a) Is absorption a unique dissociative factor within a three-factor structure, or a part of one general dissociative factor? Even when three factors are found, the specificity of the absorption factor is questionable. (b) Is absorption implicated in psychopathology? Although commonly viewed as "non-clinical" dissociation, absorption was recently hypothesized to be specifically associated with obsessive-compulsive symptoms. To address these questions, we conducted exploratory and confirmatory factor analyses on 679 undergraduates. Analyses supported the three-factor model, and a "purified" absorption scale was extracted from the original inclusive absorption factor. The purified scale predicted several psychopathology scales. As hypothesized, absorption was a stronger predictor of obsessive-compulsive symptoms than of general psychopathology. In addition, absorption was the only dissociative scale that longitudinally predicted obsessive-compulsive symptoms. We conclude that absorption is a unique and clinically relevant dissociative tendency that is particularly meaningful to obsessive-compulsive symptoms. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Comment on resonant absorption

    International Nuclear Information System (INIS)

    Hammerling, P.

    1977-01-01

    An average over angles of incidence of the usual resonant absorption function is presented. This form is appropriate under experimental conditions where the angles of incidence vary greatly and in an unknown manner. For comparison a lens-ellipsoidal mirror illumination system with a known longitudinal aberration is considered. In the latter example the angles of incidence are readily obtained and the resulting resonance absorption function evaluated. The associated fields are calculated in a similar fashion. (author)

  2. Atomic absorption instrument functional description

    International Nuclear Information System (INIS)

    Bystroff, R.I.; Boyle, W.G. Jr.; Barton, G.W. Jr.

    1976-01-01

    This report describes a proposed system for automating atomic absorption analysis. The system consists of two atomic absorption instruments and an automatic sampler that can be attached to either instrument. A computer program controls the sampling and gathers data. The program then uses the data to perform bookkeeping, data processing, and report writing

  3. Understanding Absorptive Capacities is an "Innovation Systems" Context

    DEFF Research Database (Denmark)

    Narula, Rajneesh

    2004-01-01

    This paper seeks to broaden our understanding of the concept underlying absorptive capacity atthe macro -level, paying particular attention to the growth and development perspectives. Weprovide definitions of absorptive and technological capacity, external technology flows,productivity growth....... We also undertake to explain how the nature ofabsorptive capacity changes with stages of economic development, and the importance of thedifferent aspects of absorptive capability at different stages. The relationship is not a linear one:the benefits that accrue from marginal increases in absorptive...... capability change over time.Finally, we provide a tentative and preliminary conceptual argument of how the different stagesof absorptive capacity are related to productivity growth, economic growth and employmentcreation.Key words: New economy, absorptive capacity, knowledge...

  4. The day to night absorption ratio in auroral and subauroral zone riometer measurements during auroral absorption

    International Nuclear Information System (INIS)

    Ranta, H.; Ranta, A.; Rosenberg, T.J.

    1984-01-01

    The day to night ratio of auroral absorption has been studied using data from auroral and subauroral latitudes and by application of different kinds of statistical analyses. Ratios between 0.5 and 3.0 are obtained, depending on the criteria applied to the selection of data. Previous studies obtained similar ratios, but reached different conclusions about the effective solar control of auroral absorption. It is concluded here that evidence of solar control of the day to night ratio of auroral absorption, or the lack thereof, cannot be extracted by these statistical analyses. (author)

  5. Biotin absorption by distal rat intestine

    International Nuclear Information System (INIS)

    Bowman, B.B.; Rosenberg, I.H.

    1987-01-01

    We used the in vivo intestinal loop approach, with short (10-min) and long (3-h) incubations, to examine biotin absorption in proximal jejunum, distal ileum, cecum and proximal colon. In short-term studies, luminal biotin disappearance from rat ileum was about half that observed in the jejunum, whereas absorption by proximal colon was about 12% of that in the jejunum. In 3-h closed-loop studies, the absorption of 1.0 microM biotin varied regionally. Biotin absorption was nearly complete in the small intestine after 3 h; however, only about 15% of the dose had been absorbed in the cecum and 27% in the proximal colon after 3 h. Independent of site of administration, the major fraction of absorbed biotin was recovered in the liver; measurable amounts of radioactive biotin were also present in kidney and plasma. The results support the potential nutritional significance for the rat of biotin synthesized by bacteria in the distal intestine, by demonstrating directly an absorptive capability of mammalian large bowel for this vitamin

  6. Iron absorption from adequate Filipinos meals

    International Nuclear Information System (INIS)

    Trinidad, T.P.; Madriaga, J.R.; Valdez, D.H.; Cruz, E.M.; Mallillin, A.C.; Sison, C.C.; Kuizon, M.D.

    1989-01-01

    Iron absorption from adequate Filipino meals representing the three major island groups of the Philippines (Luzon, Visayas, and Mindanao) was studied using double isotope extrinsic tag method. Mean iron absorption of the one-day meal for Metro Manila was 6.6 +- 1.26%. Central Visayas, 6.3 +- 1.15% and Southern Mindanao, 6.4 +- 1.19%. Comparison between meals (breakfast, lunch, dinner) for each region as well as one-day meal for the three regions showed no significant differences (P>0.01). Correlation tests done between iron absorption and the following iron enhancers: ascorbic acid, amount of fish, meat or poultry; and inhibitors: phytic acid and tannic acid, did not give significant results. The overall average of 6.4 +- 1.20% may be used as the iron absorption level from an adequate Filipino meal. This value can be considered as one of the bases for arriving at recommended dietary allowances for iron among Filipinos instead of the 10% iron absorption assumed in 1976. (Auth.). 21 refs.; 3 tabs.; 3 annexes

  7. Iron absorption from adequate Filipino meals

    International Nuclear Information System (INIS)

    Trinidad, T.P.; Madriaga, J.R.; Valdez, D.H.; Cruz, E.M.; Mallillin, A.C.; Sison, C.C.; Kuizon, M.D.

    1991-01-01

    Iron absorption from adequate Filipino meals representing the three major island groups of the Philippines (Luzon, Visayas and Mindanao) was studied using double isotope extrinsic tag method. Mean iron absorption of the one-day meal for Metro Manila was 6.6 ± 1.26%, Central Visayas, 6.3 ± 1.15% and Southern Mindanao, 6.4 ± 1.19%. Comparison between meals (breakfast, lunch, dinner) for each region as well as one-day meal for the three regions showed no significant differences (P > .01). Correlation tests done between iron absorption and the following iron enhancers: ascorbic acid, amount of fish, meat or poultry and inhibitors: phytic acid and tannic acid did not give significant results. The overall bar x of 6.4 ± 1.20% may be used as the non-heme iron absorption level from an adequate Filipino meal. This value can be considered as one of the bases for arriving at recommended dietary allowances for iron among Filipinos instead of the 10% iron absorption assumed in 1976

  8. Emission and Absorption Entropy Generation in Semiconductors

    DEFF Research Database (Denmark)

    Reck, Kasper; Varpula, Aapo; Prunnila, Mika

    2013-01-01

    While emission and absorption entropy generation is well known in black bodies, it has not previously been studied in semiconductors, even though semiconductors are widely used for solar light absorption in modern solar cells [1]. We present an analysis of the entropy generation in semiconductor...... materials due to emission and absorption of electromagnetic radiation. It is shown that the emission and absorption entropy generation reduces the fundamental limit on the efficiency of any semiconductor solar cell even further than the Landsberg limit. The results are derived from purely thermodynamical...

  9. Effect of oils on drug absorption

    OpenAIRE

    Palin, K.J.

    1981-01-01

    Oil and emulsion vehicles have been shown to alter the oral absorption of many drugs. This may be due to enhanced lymph flow and/or altered gastro-intestinal motility in the presence of the oils. The oral absorption of a model compound (DOT) in the presence of three chemically different oils, arachis oil, Miglyol 812 and liquid paraffin was investigated in rats, the influence of lymphatic absorption and gastro-intestinal motility being determined. The findings were applied to the for.mulation...

  10. Vitamin B12 absorption from eggs.

    Science.gov (United States)

    Doscherholmen, A; McMahon, J; Ripley, D

    1975-09-01

    The assimilation of 57Co B12 from in vivo labeled eggs was much inferior to that of a comparable amount of crystalline 57Co B12. Furthermore, the absorption varied with the form in which the eggs were served. Judged by the urinary excretion test and the plasma absorption of radioactivity the average absorption from boiled and fried eggs was more than twice that from scrambled whole eggs, but less than half that absorbed from crystalline 57Co B12.

  11. Iron absorption studies

    International Nuclear Information System (INIS)

    Ekenved, G.

    1976-01-01

    The main objective of the present work was to study iron absorption from different iron preparations in different types of subjects and under varying therapeutic conditions. The studies were performed with different radioiron isotope techniques and with a serum iron technique. The preparations used were solutions of ferrous sulphate and rapidly-disintegrating tablets containing ferrous sulphate, ferrous fumarate and ferrous carbonate and a slow-release ferrous sulphate tablet of an insoluble matrix type (Duroferon Durules). The serum iron method was evaluated and good correlation was found between the serum iron response and the total amount of iron absorbed after an oral dose of iron given in solution or in tablet form. New technique for studying the in-vivo release properties of tablets was presented. Iron tablets labelled with a radio-isotope were given to healthy subjects. The decline of the radioactivity in the tablets was followed by a profile scanning technique applied to different types of iron tablets. The release of iron from the two types of tablets was shown to be slower in vivo than in vitro. It was found that co-administration of antacids and iron tablets led to a marked reduction in the iron absorption and that these drugs should not be administered sumultaneously. A standardized meal markedly decreased the absorbability of iron from iron tablets. The influence of the meal was more marked with rapidly-disintegrating than with slow-release ferrous sulphate tablets. The absorption from rapidly-disintegrating and slow-release ferrous sulphate tablets was compared under practical clinical conditions during an extended treatment period. The studies were performed in healthy subjects, blood donors and patients with iron deficiency anaemia and it was found that the absorption of iron from the slow-release tablets was significantly better than from the rapidly-disintegrating tablets in all three groups of subjects. (author)

  12. Absorption properties of identical atoms

    International Nuclear Information System (INIS)

    Sancho, Pedro

    2013-01-01

    Emission rates and other optical properties of multi-particle systems in collective and entangled states differ from those in product ones. We show the existence of similar effects in the absorption probabilities for (anti)symmetrized states of two identical atoms. The effects strongly depend on the overlapping between the atoms and differ for bosons and fermions. We propose a viable experimental verification of these ideas. -- Highlights: •The absorption rates of a pair of identical atoms in product and (anti)symmetrized states are different. •The modifications of the optical properties are essentially determined by the overlapping between the atoms. •The absorption properties differ, in some cases, for bosons and fermions

  13. Phytases for improved iron absorption

    DEFF Research Database (Denmark)

    Nielsen, Anne Veller Friis; Meyer, Anne S.

    2016-01-01

    Phytase enzymes present an alternative to iron supplements, because they have been shown to improve iron absorption by means of catalysing the degradation of a potent iron absorption inhibitor: phytic acid. Phytic acid is a hexaphosphate of inositol and is particularly prevalent in cereal grains......, where it serves as a storage molecule for phosphorous. Phytic acid is also associated with minerals. The minerals are bound by chelation to the negatively charged phosphate groups in phytic acid. Phytases catalyse the dephosphorylation of phytic acid, thus releasing bound minerals to make them available...... for absorption. This article presents research on phytase catalysis in gastric conditions and considers potential benefits and drawbacks for using phytases as a food supplement....

  14. Enhancement of the atomic absorbance of Cr, Zn, Cd, and Pb in metal furnace atomic absorption spectrometry using absorption tubes

    Directory of Open Access Journals (Sweden)

    Yuya Koike

    2017-03-01

    Full Text Available Trace amounts of Cr, Zn, Cd, and Pb were determined by metal furnace atomic absorption spectrometry using absorption tubes. Various absorption tubes were designed as roof- and tube-types, and fixed above the metal furnace in order to extend the light path length. Aqueous standards and samples were injected in the metal furnace and atomized in a metal atomizer with an absorption tube (6 cm length, 15.5 mm diameter. The used of an absorption tube resulted in an enhancement of the atomic absorbance. The ratios of absorbance values with and without the roof- and tube-type absorption tubes were 1.33 and 1.11 for Cr; 1.42 and 1.99 for Zn; 1.66 and 1.98 for Cd; and 1.31 and 1.16 for Pb, respectively. The use of an absorption tube was effective for Zn and Cd analysis, as the absorbance values for these low boiling point metals doubled. The proposed method was successfully applied in the determination of Zn in tap water.

  15. Development of a new free radical absorption capacity assay method for antioxidants: aroxyl radical absorption capacity (ARAC).

    Science.gov (United States)

    Nagaoka, Shin-ichi; Nagai, Kanae; Fujii, Yuko; Ouchi, Aya; Mukai, Kazuo

    2013-10-23

    A new free radical absorption capacity assay method is proposed with use of an aroxyl radical (2,6-di-tert-butyl-4-(4'-methoxyphenyl)phenoxyl radical) and stopped-flow spectroscopy and is named the aroxyl radical absorption capacity (ARAC) assay method. The free radical absorption capacity (ARAC value) of each tocopherol was determined through measurement of the radical-scavenging rate constant in ethanol. The ARAC value could also be evaluated through measurement of the half-life of the aroxyl radical during the scavenging reaction. For the estimation of the free radical absorption capacity, the aroxyl radical was more suitable than the DPPH radical, galvinoxyl, and p-nitrophenyl nitronyl nitroxide. The ARAC value in tocopherols showed the same tendency as the free radical absorption capacities reported previously, and the tendency was independent of an oxygen radical participating in the scavenging reaction and of a medium surrounding the tocopherol and oxygen radical. The ARAC value can be directly connected to the free radical-scavenging rate constant, and the ARAC method has the advantage of treating a stable and isolable radical (aroxyl radical) in a user-friendly organic solvent (ethanol). The ARAC method was also successfully applied to a palm oil extract. Accordingly, the ARAC method would be useful in free radical absorption capacity assay of antioxidative reagents and foods.

  16. Determination of hafnium by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Yoshida, Isao; Kobayashi, Hiroshi; Ueno, Keihei.

    1977-01-01

    Optimum conditions for atomic absorption spectrophotometric determination of hafnium were investigated by use of a Jarrel-Ash AA-1 instrument which was equipped with a premixed gas burner slotted 50 mm in length and 0.4 mm in width. Absorption of hafnium, which was atomized in an nitrous oxide-acetylene flame, was measured on a resonance line at 307.29 nm. The absorption due to hafnium was enhanced in the presence of ammonium fluoride and iron(III) ion, as shown in Figs. 2 and 3, depending on their concentration. The highest absorption was attained by the addition of (0.15 -- 0.3)M ammonium fluoride, 0.07 M of iron(III) ion and 0.05 M of hydrochloric acid. An excess of the additives decreased the absorption. The presence of zirconium, which caused a significant interference in the ordinary analytical methods, did not affect the absorption due to hafnium, if the zirconium concentration is less than 0.2 M. A standard procedure was proposed; A sample containing a few mg of hafnium was dissolved in a 25-ml volumetric flask, and ammonium fluoride, ferric nitrate and hydrochloric acid were added so that the final concentrations were 0.3, 0.07 and 0.05 M, respectively. Atomic absorption was measured on the aqueous solution in a nitrous oxide-acetylene flame and the hafnium content was calculated from the absorbance. Sensitivity was as high as 12.5 μg of Hf/ml/l% absorption. The present method is especially recommendable to the direct determination of hafnium in samples containing zirconium. (auth.)

  17. Buffer-gas-induced absorption resonances in Rb vapor

    International Nuclear Information System (INIS)

    Mikhailov, Eugeniy E.; Novikova, Irina; Rostovtsev, Yuri V.; Welch, George R.

    2004-01-01

    We observe transformation of the electromagnetically induced transparency (EIT) resonance into an absorption resonance in a Λ interaction configuration in a cell filled with 87 Rb and a buffer gas. This transformation occurs as one-photon detuning of the coupling fields is varied from the atomic transition. No such absorption resonance is found in the absence of a buffer gas. The width of the absorption resonance is several times smaller than the width of the EIT resonance, and the changes of absorption near these resonances are about the same. Similar absorption resonances are detected in the Hanle configuration in a buffered cell

  18. Aerosol light absorption and its measurement: A review

    International Nuclear Information System (INIS)

    Moosmueller, H.; Chakrabarty, R.K.; Arnott, W.P.

    2009-01-01

    Light absorption by aerosols contributes to solar radiative forcing through absorption of solar radiation and heating of the absorbing aerosol layer. Besides the direct radiative effect, the heating can evaporate clouds and change the atmospheric dynamics. Aerosol light absorption in the atmosphere is dominated by black carbon (BC) with additional, significant contributions from the still poorly understood brown carbon and from mineral dust. Sources of these absorbing aerosols include biomass burning and other combustion processes and dust entrainment. For particles much smaller than the wavelength of incident light, absorption is proportional to the particle volume and mass. Absorption can be calculated with Mie theory for spherical particles and with more complicated numerical methods for other particle shapes. The quantitative measurement of aerosol light absorption is still a challenge. Simple, commonly used filter measurements are prone to measurement artifacts due to particle concentration and modification of particle and filter morphology upon particle deposition, optical interaction of deposited particles and filter medium, and poor angular integration of light scattered by deposited particles. In situ methods measure particle absorption with the particles in their natural suspended state and therefore are not prone to effects related to particle deposition and concentration on filters. Photoacoustic and refractive index-based measurements rely on the heating of particles during light absorption, which, for power-modulated light sources, causes an acoustic signal and modulation of the refractive index in the air surrounding the particles that can be quantified with a microphone and an interferometer, respectively. These methods may suffer from some interference due to light-induced particle evaporation. Laser-induced incandescence also monitors particle heating upon absorption, but heats absorbing particles to much higher temperatures to quantify BC mass

  19. Absorption of radionuclide through wounded skin

    International Nuclear Information System (INIS)

    Kusama, Tomoko; Ogaki, Kazushi; Yoshizawa, Yasuo

    1982-01-01

    The translocation and absorption of 58 Co(CoCl 2 ) through a wound was investigated experimentally with mice. Physical and chemical skin damages became the objects of the investigation. Abrasion, puncture and incision were made for types of the physical damage. The chemical damage included both acid and alkaline burns. The absorptions of the radionuclide through the contaminated wounds were measured with both a 2 inches NaI(Tl) scintillation detector and an auto well gamma counter at 15,30 and 60 min after the contamination. The radionuclide was hardly absorbed through an undamaged skin. After 30 min, 20 to 40% of the radionuclide applied on the physically damaged skin was absorbed, but was not absorbed through the chemically damaged skin. The absorption rate through the physically damaged skin reached a maximum at 15 to 60 min after the contamination. The velocity of the absorption through the physically damaged skin was 100 times as much as the chemically damaged skin. The absorption rates through the physically and the chemically damaged skins were expressed by the following formulas: A=a(1-e sup(-bt)) and A=a(e sup(bt)-1), where a and b is constant, respectively. (author)

  20. Optical absorption of irradiated carbohydrates

    International Nuclear Information System (INIS)

    Supe, A.A.; Tiliks, Yu.E.

    1994-01-01

    The optical absorption spectra of γ-irradiated carbohydrates (glucose, lactose, sucrose, maltose, and starch) and their aqueous solutions were studied. The comparison of the data obtained with the determination of the concentrations of molecular and radical products of radiolysis allows the absorption bands with maxima at 250 and 310 nm to be assigned to the radicals trapped in the irradiated carbohydrates

  1. Microwaves absorption in superconducting materials

    International Nuclear Information System (INIS)

    Biasi, R.S. de; Fernandes, A.A.R.; Pereira, R.F.R.

    1989-01-01

    Microwaves absorption measures in two superconductors ceramics systems, Y-Ba-Cu-O and Bi-Sr-Ca-Cu-O are compared with similars datas obtained in the same band of temperature by a conventional method, mutual inductance. The results suggest that the microwaves absorption can be used as single and non-destructive method for investigating the properties of ceramics superconductors. (C.G.C.) [pt

  2. In Silico Modeling of Gastrointestinal Drug Absorption: Predictive Performance of Three Physiologically Based Absorption Models.

    Science.gov (United States)

    Sjögren, Erik; Thörn, Helena; Tannergren, Christer

    2016-06-06

    Gastrointestinal (GI) drug absorption is a complex process determined by formulation, physicochemical and biopharmaceutical factors, and GI physiology. Physiologically based in silico absorption models have emerged as a widely used and promising supplement to traditional in vitro assays and preclinical in vivo studies. However, there remains a lack of comparative studies between different models. The aim of this study was to explore the strengths and limitations of the in silico absorption models Simcyp 13.1, GastroPlus 8.0, and GI-Sim 4.1, with respect to their performance in predicting human intestinal drug absorption. This was achieved by adopting an a priori modeling approach and using well-defined input data for 12 drugs associated with incomplete GI absorption and related challenges in predicting the extent of absorption. This approach better mimics the real situation during formulation development where predictive in silico models would be beneficial. Plasma concentration-time profiles for 44 oral drug administrations were calculated by convolution of model-predicted absorption-time profiles and reported pharmacokinetic parameters. Model performance was evaluated by comparing the predicted plasma concentration-time profiles, Cmax, tmax, and exposure (AUC) with observations from clinical studies. The overall prediction accuracies for AUC, given as the absolute average fold error (AAFE) values, were 2.2, 1.6, and 1.3 for Simcyp, GastroPlus, and GI-Sim, respectively. The corresponding AAFE values for Cmax were 2.2, 1.6, and 1.3, respectively, and those for tmax were 1.7, 1.5, and 1.4, respectively. Simcyp was associated with underprediction of AUC and Cmax; the accuracy decreased with decreasing predicted fabs. A tendency for underprediction was also observed for GastroPlus, but there was no correlation with predicted fabs. There were no obvious trends for over- or underprediction for GI-Sim. The models performed similarly in capturing dependencies on dose and

  3. Total absorption by degenerate critical coupling

    Energy Technology Data Exchange (ETDEWEB)

    Piper, Jessica R., E-mail: jrylan@stanford.edu; Liu, Victor; Fan, Shanhui, E-mail: shanhui@stanford.edu [Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States)

    2014-06-23

    We consider a mirror-symmetric resonator with two ports. We show that, when excited from a single port, complete absorption can be achieved through critical coupling to degenerate resonances with opposite symmetry. Moreover, any time two resonances with opposite symmetry are degenerate in frequency and absorption is always significantly enhanced. In contrast, when two resonances with the same symmetry are nearly degenerate, there is no absorption enhancement. We numerically demonstrate these effects using a graphene monolayer on top of a photonic crystal slab, illuminated from a single side in the near-infrared.

  4. Gas treating absorption theory and practice

    CERN Document Server

    Eimer, Dag

    2014-01-01

    Gas Treating: Absorption Theory and Practice provides an introduction to the treatment of natural gas, synthesis gas and flue gas, addressing why it is necessary and the challenges involved.  The book concentrates in particular on the absorption-desorption process and mass transfer coupled with chemical reaction. Following a general introduction to gas treatment, the chemistry of CO2, H2S and amine systems is described, and selected topics from physical chemistry with relevance to gas treating are presented. Thereafter the absorption process is discussed in detail, column hardware is explain

  5. Enriching Absorptive Capacity through Social Interaction

    NARCIS (Netherlands)

    Hotho, Jasper J.; Becker-Ritterspach, Florian; Saka-Helmhout, Ayse

    Absorptive capacity is frequently highlighted as a key determinant of knowledge transfer within multinational enterprises. But how individual behaviour translates into absorptive capacity at the subsidiary level, and how this is contingent on subsidiaries' social context, remains under-addressed.

  6. Multiphoton absorption coefficients in solids: an universal curve

    International Nuclear Information System (INIS)

    Brandi, H.S.; Araujo, C.B. de

    1983-04-01

    An universal curve for the frequency dependence of the multiphoton absorption coefficient is proposed based on a 'non-perturbative' approach. Specific applications have been made to obtain two, three, four and five photons absorption coefficient in different materials. Properly scaling of the two photon absorption coefficient and the use of the universal curve yields results for the higher order absorption coefficients in good agreement with the experimental data. (Author) [pt

  7. Interferometric measurement of lines shift in flames in connection with interpretation of lined absorption method in atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    L'vov, B.V.; Polzik, L.K.; Katskov, D.A.; Kruglikova, L.P.

    1975-01-01

    This paper is concerned with interferometric measuring of the line shift in flames in the view of interpretation of absorption lines in the atomic absorption spectroscopy. The newly measured line shifts were compared to the known data on Lorentz broadening of the same lines obtained by methods free of the systematic errors. The resonant lines of the alkaline earth elements (Sr, Ca, Ba) were investigated. To reduce self-absorption in the flame the solutions with minimum concentrations of the elements were used. The computation scheme includes the spectrometer apparatus width and line broadening due to the self-absorption. Formulae are given for computing the values studied. Good agreement was observed between the computed and experimental results. Error analysis was performed. It was concluded that any line shifts in the hydrocarbons were correctly taken into an account in the absolute computations of absorption

  8. Anomalous infrared absorption in granular superconductors

    International Nuclear Information System (INIS)

    Carr, G.L.; Garland, J.C.; Tanner, D.B.

    1983-01-01

    Granular superconductors are shown to have a far-infrared absorption that is larger when the samples are superconducting than when they are normal. By constrast, theoretical models for these materials predict that when the samples become superconducting, the absorption should decrease

  9. Oligofructose stimulates calcium absorption in adolescents

    NARCIS (Netherlands)

    Heuvel, E.G.H.M. van den; Muys, T.; Dokkum, W. van; Schaafsma, G.

    1999-01-01

    Background: In rats, nondigestible oligosaccharides stimulate calcium absorption. Recently, this effect was also found in human subjects. Objective: The objective of the study was to investigate whether consumption of 15 g oligofructose/d stimulates calcium absorption in male adolescents. Design:

  10. Optical absorption of carbon-gold core-shell nanoparticles

    Science.gov (United States)

    Wang, Zhaolong; Quan, Xiaojun; Zhang, Zhuomin; Cheng, Ping

    2018-01-01

    In order to enhance the solar thermal energy conversion efficiency, we propose to use carbon-gold core-shell nanoparticles dispersed in liquid water. This work demonstrates theoretically that an absorbing carbon (C) core enclosed in a plasmonic gold (Au) nanoshell can enhance the absorption peak while broadening the absorption band; giving rise to a much higher solar absorption than most previously studied core-shell combinations. The exact Mie solution is used to evaluate the absorption efficiency factor of spherical nanoparticles in the wavelength region from 300 nm to 1100 nm as well as the electric field and power dissipation profiles inside the nanoparticles at specified wavelengths (mostly at the localized surface plasmon resonance wavelength). The field enhancement by the localized plasmons at the gold surfaces boosts the absorption of the carbon particle, resulting in a redshift of the absorption peak with increased peak height and bandwidth. In addition to spherical nanoparticles, we use the finite-difference time-domain method to calculate the absorption of cubic core-shell nanoparticles. Even stronger enhancement can be achieved with cubic C-Au core-shell structures due to the localized plasmonic resonances at the sharp edges of the Au shell. The solar absorption efficiency factor can exceed 1.5 in the spherical case and reach 2.3 in the cubic case with a shell thickness of 10 nm. Such broadband absorption enhancement is in great demand for solar thermal applications including steam generation.

  11. Flame emission, atomic absorption and fluorescence spectrometry

    International Nuclear Information System (INIS)

    Horlick, G.

    1980-01-01

    Six hundred and thirty references are cited in this review. The information in the review is divided into 12 major areas: books, reviews, and bibliographies; fundamental studies in flames; developments in instrumentation; measurement techniques and procedure; flame emission spectrometry; flame atomic absorption spectrometry; flame molecular absorption spectrometry; electrothermal atomization atomic absorption spectroscopy; hydride generation techniques; graphite furnace atomic emission spectrometry; atomic fluorescence spectrometry; and analytical comparisons

  12. Phytosterol glycosides reduce cholesterol absorption in humans

    OpenAIRE

    Lin, Xiaobo; Ma, Lina; Racette, Susan B.; Anderson Spearie, Catherine L.; Ostlund, Richard E.

    2009-01-01

    Dietary phytosterols inhibit intestinal cholesterol absorption and regulate whole body cholesterol excretion and balance. However, they are biochemically heterogeneous and a portion is glycosylated in some foods with unknown effects on biological activity. We tested the hypothesis that phytosterol glycosides reduce cholesterol absorption in humans. Phytosterol glycosides were extracted and purified from soy lecithin in a novel two-step process. Cholesterol absorption was measured in a series ...

  13. Electromagnetically induced absorption via incoherent collisions

    International Nuclear Information System (INIS)

    Yang Xihua; Sheng Jiteng; Xiao Min

    2011-01-01

    We conduct theoretical studies on electromagnetically induced absorption via incoherent collisions in an inhomogeneously broadened ladder-type three-level system with the density-matrix approach. The effects of the collision-induced coherence decay rates as well as the probe laser field intensity on the probe field absorption are examined. It is shown that with the increase of the collisional decay rates in a moderate range, a narrow dip due to electromagnetically induced transparency superimposed on the Doppler-broadened absorption background can be turned into a narrow peak under the conditions that the probe field intensity is not very weak as compared to the pump field, which results from the enhancement of constructive interference and suppression of destructive interference between one-photon and multiphoton transition pathways. The physical origin of the collision-assisted electromagnetically induced absorption is analyzed with a power-series solution of the density-matrix equations.

  14. Absorption chillers: Part of the solution

    International Nuclear Information System (INIS)

    Occhionero, A.J.; Hughes, P.J.; Reid, E.A.

    1991-01-01

    Acid rain, ozone depletion, global warming, and implementation economics are considered as they relate to the advisability of expanding the application of absorption chillers. Introductory and background information are provided to put the discussion in the proper context. Then all four issues are discussed separately as they relate to absorption chillers. Acid rain and ozone depletion concerns, and implementation economics, are found to support the expanded use of absorption chillers. The global warming concern is found to be more of a gray area, but the areas of benefit correspond well with the conditions of greatest economic advantage. All things considered, absorption chillers are believed to be part of the environmental and economic solution. It is further believed that integrated resource planning (IRP) processes that consider electric and gas technologies on an equal footing would come to the same conclusion for many regions of the United States. 9 refs., 3 tabs

  15. Insulin analogues with improved absorption characteristics.

    Science.gov (United States)

    Brange, J; Hansen, J F; Langkjaer, L; Markussen, J; Ribel, U; Sørensen, A R

    1992-01-01

    The insulin preparations available today are not ideal for therapy as s.c. injection does not provide a physiological insulin profile. With the aim to improve the absorption properties recombinant DNA technology has been utilized to design novel insulin molecules with changed physico-chemical characteristics and hence altered subcutaneous absorption kinetics. Soluble, long-acting human insulin analogues in which the isoelectric point has been increased from 5.4 to approx. 7 are absorbed very slowly, providing a more constant basal insulin delivery with lower day-to-day variation than present protracted preparations. In addition they have better storage stability. Rapid-acting human insulin analogues with largely reduced self-association are absorbed substantially faster from subcutaneous tissue than current regular insulin and thus are better suited for bolus injection. The absorption kinetics of these analogues have been able to explain the mechanism behind the dose effect on insulin absorption rate.

  16. Studies on absorption coefficient near edge of multi elements

    International Nuclear Information System (INIS)

    Eisa, M.H.; Shen, H.; Yao, H.Y.; Mi, Y.; Zhou, Z.Y.; Hu, T.D.; Xie, Y.N.

    2005-01-01

    X-ray absorption near edge structure (XANES) was used to study the near edge mass-absorption coefficients of seven elements, such as, Ti, V, Fe, Co, Ni, Cu and Zn. It is well known that, on the near edge absorption of element, when incident X-ray a few eV change can make the absorption coefficient an order magnitude alteration. So that, there are only a few points mass-absorption coefficient at the near edge absorption and that always average value in published table. Our results showed a wide range of data, the total measured data of mass-absorption coefficient of the seven elements was about 505. The investigation confirmed that XANES is useful technique for multi-element absorption coefficient measurement. Details of experimental methods and results are given and discussed. The experimental work has been performed at Beijing Synchrotron Radiation Facility. The measured values were compared with the published data. Good agreement between experimental results and published data is obtained

  17. Studies on absorption coefficient near edge of multi elements

    Science.gov (United States)

    Eisa, M. H.; Shen, H.; Yao, H. Y.; Mi, Y.; Zhou, Z. Y.; Hu, T. D.; Xie, Y. N.

    2005-12-01

    X-ray absorption near edge structure (XANES) was used to study the near edge mass-absorption coefficients of seven elements, such as, Ti, V, Fe, Co, Ni, Cu and Zn. It is well known that, on the near edge absorption of element, when incident X-ray a few eV change can make the absorption coefficient an order magnitude alteration. So that, there are only a few points mass-absorption coefficient at the near edge absorption and that always average value in published table. Our results showed a wide range of data, the total measured data of mass-absorption coefficient of the seven elements was about 505. The investigation confirmed that XANES is useful technique for multi-element absorption coefficient measurement. Details of experimental methods and results are given and discussed. The experimental work has been performed at Beijing Synchrotron Radiation Facility. The measured values were compared with the published data. Good agreement between experimental results and published data is obtained.

  18. Saturable absorption in detonation nanodiamond dispersions

    Science.gov (United States)

    Vanyukov, Viatcheslav; Mikheev, Gennady; Mogileva, Tatyana; Puzyr, Alexey; Bondar, Vladimir; Lyashenko, Dmitry; Chuvilin, Andrey

    2017-07-01

    We report on a saturable absorption in aqueous dispersions of nanodiamonds with femtosecond laser pulse excitation at a wavelength of 795 nm. The open aperture Z-scan experiments reveal that in a wide range of nanodiamond particle sizes and concentrations, a light-induced increase of transmittance occurs. The transmittance increase originates from the saturation of light absorption and is associated with a light absorption at 1.5 eV by graphite and dimer chains (Pandey dimer chains). The obtained key nonlinear parameters of nanodiamond dispersions are compared with those of graphene and carbon nanotubes, which are widely used for the mode-locking.

  19. Absorption heat cycles. An experimental and theoretical study

    International Nuclear Information System (INIS)

    Abrahamsson, K.

    1993-09-01

    A flow sheeting programme, SHPUMP, was developed for simulating different absorption heat cycles. The programme consists of ten different modules which allow the user to construct his own absorption cycle. The ten modules configurate evaporators, absorbers, generators, rectifiers, condensers, solution heat exchangers, pumps, valves, mixers and splitters. Seven basic and well established absorption cycles are available in the configuration data base of the programme. A new Carnot model is proposed heat cycles. Together with exergy analysis, general equations for the Carnot coefficient of performance and equations for thermodynamic efficiency, exergetic efficiency and exergy index, are derived, discussed and compared for both absorption heat pumps and absorption heat transformers. Utilizing SHPUMP, simulation results are presented for different configurations where absorption heat cycles are suggested to be incorporated in three different unit operations within both pulp and paper and oleochemical industries. One of the application studies reveled that an absorption heat transformer incorporated with an evaporation plant in a major pulp and paper industry, would save 18% of the total prime energy consumption in one of the evaporation plants. It was also concluded that installing an absorption heat pump in a paper drying plant would result in steam savings equivalent to 12 MW. An experimental absorption heat transformer unit operating with self-circulation has been modified and thoroughly tested. A reference heat transformer plant has been designed and installed in a major pulp and paper mill where it is directly incorporated with one of the evaporation plants. Preliminary plant operation data are presented. 72 refs, 63 figs, 33 tabs

  20. UV laser long-path absorption spectroscopy

    Science.gov (United States)

    Dorn, Hans-Peter; Brauers, Theo; Neuroth, Rudolf

    1994-01-01

    Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive

  1. Infrared absorption of human breast tissues in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Liu Chenglin [Department of Physics, Surface Physics Laboratory (National Key laboratory), Synchrotron Radiation Research Center, Fudan University, Shanghai 200433 (China); Physics Department of Yancheng Teachers' College, Yancheng 224002 (China); Zhang Yuan [Department of Physics, Surface Physics Laboratory (National Key laboratory), Synchrotron Radiation Research Center, Fudan University, Shanghai 200433 (China); Yan Xiaohui [Department of Physics, Surface Physics Laboratory (National Key laboratory), Synchrotron Radiation Research Center, Fudan University, Shanghai 200433 (China); Zhang Xinyi [Department of Physics, Surface Physics Laboratory (National Key laboratory), Synchrotron Radiation Research Center, Fudan University, Shanghai 200433 (China) and Shanghai Research Center of Acupuncture and Meridian, Pudong, Shanghai 201203 (China)]. E-mail: xy-zhang@fudan.edu.cn; Li Chengxiang [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Yang Wentao [Cancer Hospital, Medical Center, Fudan University, Shanghai 200032 (China); Shi Daren [Cancer Hospital, Medical Center, Fudan University, Shanghai 200032 (China)

    2006-07-15

    The spectral characteristics of human breast tissues in normal status and during different cancerous stages have been investigated by synchrotron radiation based Fourier transform infrared (SR-FTIR) absorption spectroscopy. Thanks to the excellent synchrotron radiation infrared (IR) source, higher resolving power is achieved in SR-FTIR absorption spectra than in conventional IR absorption measurements. Obvious variations in IR absorption spectrum of breast tissues were found as they change from healthy to diseased, or say in progression to cancer. On the other hand, some specific absorption peaks were found in breast cancer tissues by SR-FTIR spectroscopic methods. These spectral characteristics of breast tissue may help us in early diagnosis of breast cancer.

  2. Nonresonant absorption of one photon by one atom and resonant absorption of two photons by two atoms

    International Nuclear Information System (INIS)

    Mizushima, Masataka

    1990-01-01

    When a radiation field of frequency ω 1 interacts with atoms, etch of which has a transition frequency ω ba =(E b -E a )/h, with ω 1 -ω ba =Δ≠0, nonresonant absorption can take place with probability P 1 inversely proportional to Δ 2 (a pressure broadening). When another radiation field of frequency ω 2 , such that ω 1 +ω 2 =2ω ba, interacts simultaneously with the gas a resonant two-photon absorption can take place in addition to the nonresonant absorption. The probability of this two-photon absorption process, P 2 , is found to be inversely proportional to Δ 4 . If Ω=| | is the Rabi frequency of the transition, it is found that P 2 /(P 1 (Δ)+P 1 (-Δ)) is given by 12 {Ω(-Δ)Ω(-Δ)} 2 / {Δ 2 (Ω(-Δ) 2 + Ω(Δ) 2 )}. (author)

  3. Absorption of hydrogen in vanadium, enhanced by ion bombardment; Ionenbeschussunterstuetzte Absorption des Wasserstoffs in Vanadium

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, H.; Lammers, M. [Inst. fuer Technologie- und Wissenstransfer, Soest (Germany); Mueller, K.H. [Inst. fuer Technologie- und Wissenstransfer, Soest (Germany)]|[Paderborn Univ. (Gesamthochschule), Soest (Germany). Fachbereich 16 - Elektrische Energietechnik; Kiss, G.; Kemeny, Z. [Technical Univ. Budapest (Hungary)

    1998-12-31

    Prior to hydrogen implantation into vanadium, the vanadium specimen usually is exposed to an activation process and is then heated at 1 atm hydrogen to temperatures between 500 and 600 C, subsequently cooled down in several steps. Within this temperature range, hydrogen solubility increases with declining temperature. A decisive factor determining hydrogen absorption is the fact that at temperatures above 250 C, oxygen desorbs from the material surface and thus no longer inhibits hydrogen absorption. Therefore a different approach was chosen for the experiments reported: Hydrogen absorption under UHV conditions at room temperature. After the usual activation process, the vanadium surface was cleaned by 5 keV Ar{sup +} ion bombardment. Thus oxygen absorption at the specimen surface (and new reactions with oxygen from the remaining gas) could be avoided, or removed. By means of thermal desorption mass spectrometry (TDMS), hydrogen absorption as a function of argon ion dose was analysed. TDMS measurements performed for specimens treated by ion bombardment prior to H{sup 2} exposure showed two H{sup 2} desorption peaks, in contrast to the profiles measured with specimens not exposed to ion bombardment. It is assumed that the ion bombardment disturbs the crystal structure so that further sites for hydrogen absorption are produced. (orig./CB) [Deutsch] Bei der Beladung von Vandium mit Wasserstoff wird ueblicherweise die Probe nach einer Aktivierungsprozedur bei 1 atm Wasserstoff auf Temperaturen im Bereich von 500 bis 600 C hochgeheizt und danach schrittweise abgekuehlt. In diesem Temperaturbereich nimmt die Wasserstoffloeslichkeit mit abnehmender Temperatur zu. Entscheidend fuer die Beladung ist aber auch die Tatsache, dass bei Temperaturen groesser 250 C Sauerstoff von der Oberflaeche desorbiert und dadurch die Absorption von Wasserstoff nicht mehr blockieren kann. Im Rahmen der hier beschriebenen Untersuchungen sollte die Wasserstoffbeladung unter UHV-Bedingungen bei

  4. A Low-Cost Quantitative Absorption Spectrophotometer

    Science.gov (United States)

    Albert, Daniel R.; Todt, Michael A.; Davis, H. Floyd

    2012-01-01

    In an effort to make absorption spectrophotometry available to high school chemistry and physics classes, we have designed an inexpensive visible light absorption spectrophotometer. The spectrophotometer was constructed using LEGO blocks, a light emitting diode, optical elements (including a lens), a slide-mounted diffraction grating, and a…

  5. Ultrafast THz Saturable Absorption in Semiconductors

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry; Hoffmann, Matthias C.

    2011-01-01

    We demonstrate THz saturable absorption in n-doped semiconductors GaAs, GaP, and Ge in a nonlinear THz time-domain spectroscopy experiment. Saturable absorption is caused by sample conductivity modulation due to electron heating and satellite valley scattering in the field of a strong THz pulse....

  6. High temperature measurement of water vapor absorption

    Science.gov (United States)

    Keefer, Dennis; Lewis, J. W. L.; Eskridge, Richard

    1985-01-01

    An investigation was undertaken to measure the absorption coefficient, at a wavelength of 10.6 microns, for mixtures of water vapor and a diluent gas at high temperature and pressure. The experimental concept was to create the desired conditions of temperature and pressure in a laser absorption wave, similar to that which would be created in a laser propulsion system. A simplified numerical model was developed to predict the characteristics of the absorption wave and to estimate the laser intensity threshold for initiation. A non-intrusive method for temperature measurement utilizing optical laser-beam deflection (OLD) and optical spark breakdown produced by an excimer laser, was thoroughly investigated and found suitable for the non-equilibrium conditions expected in the wave. Experiments were performed to verify the temperature measurement technique, to screen possible materials for surface initiation of the laser absorption wave and to attempt to initiate an absorption wave using the 1.5 kW carbon dioxide laser. The OLD technique was proven for air and for argon, but spark breakdown could not be produced in helium. It was not possible to initiate a laser absorption wave in mixtures of water and helium or water and argon using the 1.5 kW laser, a result which was consistent with the model prediction.

  7. Energy absorption build-up factors in teeth

    International Nuclear Information System (INIS)

    Manjunatha, H.C.; Rudraswamy, B.

    2012-01-01

    Geometric progression fitting method has been used to compute energy absorption build-up factor of teeth [enamel outer surface, enamel middle, enamel dentin junction towards enamel, enamel dentin junction towards dentin, dentin middle and dentin inner surface] for wide energy range (0.015-15 MeV) up to the penetration depth of 40 mean free path. The dependence of energy absorption build-up factor on incident photon energy, penetration depth, electron density and effective atomic number has also been studied. The energy absorption build-up factors increases with the penetration depth and electron density of teeth. So that the degree of violation of Lambert-Beer (I = I 0 e -μt ) law is less for least penetration depth and electron density. The energy absorption build-up factors for different regions of teeth are not same hence the energy absorbed by the different regions of teeth is not uniform which depends on the composition of the medium. The relative dose of gamma in different regions of teeth is also estimated. Dosimetric implication of energy absorption build-up factor in teeth has also been discussed. The estimated absorption build up factors in different regions of teeth may be useful in the electron spin resonance dosimetry. (author)

  8. The origin of electromagnetically induced absorption

    International Nuclear Information System (INIS)

    Park, Jong Dae; Hwang, Sung Tae; Lee, Ho Seong; Park, Sung Jong; Cho, Hyuck; Choi, Won Sik

    2000-01-01

    Recently, there have been a lot of interests in the coherence superposition of atomic states which are formed by laser fields. Coherent population trapping(CTP), electromagnetically induced transparency(EIT), enhancement of the refractive index without absorption, lasing without inversion(LWI), and electromagnetically induced absorption(EIA) are the examples where coherence effects are important. Previously, the spontaneous transfer of the light-induced coherence from the excited level to the ground one was emphasized for the essential ingredient for electromagnetically induced absorption. In this paper, we have considered a case where linearly polarized coupling laser and probe laser are applied to the same degenerated ground and excited levels. We have solved the master equations for density matrix using time varying Hamiltonian and studied the absorption spectra at various conditions. We demonstrate that EIA can be observed without spontaneous transfer of the light-induced coherence in F g = 1 -> F e = 2 D2 transitions of Hydrogen atoms

  9. Narrative absorption

    DEFF Research Database (Denmark)

    Narrative Absorption brings together research from the social sciences and Humanities to solve a number of mysteries: Most of us will have had those moments, of being totally absorbed in a book, a movie, or computer game. Typically we do not have any idea about how we ended up in such a state. No...

  10. Absorption-heat-pump system

    Science.gov (United States)

    Grossman, G.; Perez-Blanco, H.

    1983-06-16

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  11. A transient absorption study of allophycocyanin

    Indian Academy of Sciences (India)

    Transient dynamics of allophycocyanin trimers and monomers are observed by using the pump-probe, transient absorption technique. The origin of spectral components of the transient absorption spectra is discussed in terms of both kinetics and spectroscopy. We find that the energy gap between the ground and excited ...

  12. In vitro and in vivo percutaneous absorption of retinol from cosmetic formulations: Significance of the skin reservoir and prediction of systemic absorption

    International Nuclear Information System (INIS)

    Yourick, Jeffrey J.; Jung, Connie T.; Bronaugh, Robert L.

    2008-01-01

    The percutaneous absorption of retinol (Vitamin A) from cosmetic formulations was studied to predict systemic absorption and to understand the significance of the skin reservoir in in vitro absorption studies. Viable skin from fuzzy rat or human subjects was assembled in flow-through diffusion cells for in vitro absorption studies. In vivo absorption studies using fuzzy rats were performed in glass metabolism cages for collection of urine, feces, and body content. Retinol (0.3%) formulations (hydroalcoholic gel and oil-in-water emulsion) containing 3 H-retinol were applied and absorption was measured at 24 or 72 h. All percentages reported are % of applied dose. In vitro studies using human skin and the gel and emulsion vehicles found 0.3 and 1.3% retinol, respectively, in receptor fluid at 24 h. Levels of absorption in the receptor fluid increased over 72 h with the gel and emulsion vehicles. Using the gel vehicle, in vitro rat skin studies found 23% in skin and 6% in receptor fluid at 24 h, while 72-h studies found 18% in skin and 13% in receptor fluid. Thus, significant amounts of retinol remained in rat skin at 24 h and decreased over 72 h, with proportional increases in receptor fluid. In vivo rat studies with the gel found 4% systemic absorption of retinol after 24 h and systemic absorption did not increase at 72 h. Retinol remaining in rat skin after in vivo application was 18% and 13% of the applied dermal dose after 24 and 72 h, respectively. Similar observations were made with the oil-in water emulsion vehicle in the rat. Retinol formed a reservoir in rat skin both in vivo and in vitro. Little additional retinol was bioavailable after 24 h. Comparison of these in vitro and in vivo results for absorption through rat skin indicates that the 24-h in vitro receptor fluid value accurately estimated 24-h in vivo systemic absorption. Therefore, the best single estimate of retinol systemic absorption from in vitro human skin studies is the 24-h receptor fluid

  13. MNC Knowledge Transfer, Subsidiary Absorptive Capacity and HRM

    DEFF Research Database (Denmark)

    Minbaeva, Dana; Pedersen, Torben; Björkman, Ingmar

    2014-01-01

    Based on a sample of 169 subsidiaries of multinational corporations (MNCs) operating in the USA, Russia, and Finland, this paper investigates the relationship between MNC subsidiary HRM practices, absorptive capacity and knowledge transfer. First, we examine the relationship between the application...... of specific HRM practices and the level of the absorptive capacity. Second, we suggest that absorptive capacity should be conceptualized as being comprised of both employees’ ability and motivation. Further, results indicate that both ability and motivation (absorptive capacity) are needed to facilitate...

  14. Transdermic absorption of Melagenina II

    International Nuclear Information System (INIS)

    Hernandez Gonzalez, I.; Martinez Lopez, B.; Ruiz Pena, M.; Caso Pena, R.

    1997-01-01

    The transdermic absorption of Melagenina II (MII) was evaluated. MII was a labelled with 125I by the yodogen method and purified by column chromatography with Sephadex LH-20 in ethanol: water (7:3). In vitro absorption of ( 125I ) - MII thought human skin was carried out in Keshary-Chien modified diffusion cells. Tape stripping method was applied after 24 hours to evaluate the accumulated activity in dermis and epidermis. In vivo assays were performed in Sprague Dawley rats to analyze absorption of MII until 24 hours after a single application and for five days a low penetrability of the drug while in vivo there were not found blood levels significantly greater than zero , nevertheless and important amount of radioactivity was found in feces and urine. The activity was concentrated mainly in the application site in both models

  15. Architecture for Absorption Based Heaters

    Science.gov (United States)

    Moghaddam, Saeed; Chugh, Devesh

    2018-04-24

    An absorption based heater is constructed on a fluid barrier heat exchanging plate such that it requires little space in a structure. The absorption based heater has a desorber, heat exchanger, and absorber sequentially placed on the fluid barrier heat exchanging plate. The vapor exchange faces of the desorber and the absorber are covered by a vapor permeable membrane that is permeable to a refrigerant vapor but impermeable to an absorbent. A process fluid flows on the side of the fluid barrier heat exchanging plate opposite the vapor exchange face through the absorber and subsequently through the heat exchanger. The absorption based heater can include a second plate with a condenser situated parallel to the fluid barrier heat exchanging plate and opposing the desorber for condensation of the refrigerant for additional heating of the process fluid.

  16. Mercury absorption in aqueous hypochlorite

    International Nuclear Information System (INIS)

    Zhao, L.L.; Rochelle, G.T.

    1999-01-01

    The absorption of elemental Hg vapor into aqueous hypochlorite was measured in a stirred tank reactor at 25 and 55C. NaOCl strongly absorbs Hg even at high pH. Low pH, high Cl - and high-temperature favor mercury absorption. Aqueous free Cl 2 was the active species that reacted with mercury. However, chlorine desorption was evident at high Cl - and pH 15 M -1 s -1 at 25C and 1.4x10 17 M -1 s -1 at 55C. Gas-phase reaction was observed between Hg and Cl 2 on apparatus surfaces. Strong mercury absorption in water was also detected with Cl 2 present. Results indicate that the chlorine concentration, moisture, and surface area contribute positively to mercury removal. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  17. Quantum of optical absorption in two-dimensional semiconductors.

    Science.gov (United States)

    Fang, Hui; Bechtel, Hans A; Plis, Elena; Martin, Michael C; Krishna, Sanjay; Yablonovitch, Eli; Javey, Ali

    2013-07-16

    The optical absorption properties of free-standing InAs nanomembranes of thicknesses ranging from 3 nm to 19 nm are investigated by Fourier transform infrared spectroscopy. Stepwise absorption at room temperature is observed, arising from the interband transitions between the subbands of 2D InAs nanomembranes. Interestingly, the absorptance associated with each step is measured to be ∼1.6%, independent of thickness of the membranes. The experimental results are consistent with the theoretically predicted absorptance quantum, AQ = πα/nc for each set of interband transitions in a 2D semiconductor, where α is the fine structure constant and nc is an optical local field correction factor. Absorptance quantization appears to be universal in 2D systems including III-V quantum wells and graphene.

  18. Absorption of proteins and amino acids

    International Nuclear Information System (INIS)

    Jeejeebhoy, K.N.

    1976-01-01

    Although the absorption of proteins and amino acids is an important issue in nutrition, its measurement is not common because of the methodological difficulties. Complications are attributable in particular to the magnitude of endogenous protein secretion and to the diversity of absorption mechanisms for amino acids either as individual units or as peptides. Methods for studying absorption include balance techniques, tolerance tests, tracer techniques using proteins or amino acids labelled with 131 I, 3 H, or 15 N, intestinal perfusion studies, and others; they must be selected according to the nature of the information sought. Improvements over the current methods would be useful. (author)

  19. Gastrointestinal absorption of uranium in man

    International Nuclear Information System (INIS)

    Larsen, R.P.; Orlandini, K.A.

    1984-01-01

    A method has been established for determining the fractional absorption of uranium directly in man. Measurements are made of the urinary excretion rates of uranium for individuals whose drinking water has a high 234 U to 238 U activity ratio and is the primary source of 234 U in their diets. For two individuals, the values obtained for the fractional absorption of 234 U were 0.004 and 0.006. The values obtained for the fractional absorption of 238 U, using a literature value for the 238 U intake from food, were 0.008 and 0.015. The present ICRP value is 0.20. 7 references, 1 table

  20. Evidence for pion absorption on four nucleons

    International Nuclear Information System (INIS)

    Rzehorz, B.; Backenstoss, G.; Dzemidzic, M.; Zagreb Univ.; Furic, M.; Zagreb Univ.; Hoffart, A.; Petkovic, T.; Zagreb Univ.; Ullrich, H.; Weyer, H.J.; Weiser, D.; Wildi, M.

    1996-01-01

    Experimental spectra from the coincident detection of three nucleons after the pion absorption in 4 He are displayed. The presence of a mechanism with four nucleons participating in the absorption process is made obvious. The total cross-sections for this absorption mode are: σ 4NA abs =(1.0±0.2)mb at T π =120 MeV and σ 4NA abs =(2.18± 0.65) mb at T π =210 MeV. (orig.)

  1. Hopping absorption edge in silicon inversion layers

    International Nuclear Information System (INIS)

    Kostadinov, I.Z.

    1983-09-01

    The low frequency gap observed in the absorption spectrum of silicon inversion layers is related to the AC variable range hopping. The frequency dependence of the absorption coefficient is calculated. (author)

  2. Absorption in one-dimensional metallic-dielectric photonic crystals

    International Nuclear Information System (INIS)

    Yu Junfei; Shen Yifeng; Liu Xiaohan; Fu Rongtang; Zi Jian; Zhu Zhiqiang

    2004-01-01

    We show theoretically that the absorption of one-dimensional metallic-dielectric photonic crystals can be enhanced considerably over the corresponding constituent metal. By properly choosing the structural and material parameters, the absorption of one-dimensional metallic-dielectric photonic crystals can be enhanced by one order of magnitude in the visible and in the near infrared regions. It is found that the absorptance of such photonic crystals increases with increasing number of periods. Rules on how to obtain a absorption enhancement in a certain frequency range are discussed. (letter to the editor)

  3. Phytosterol glycosides reduce cholesterol absorption in humans

    Science.gov (United States)

    Lin, Xiaobo; Ma, Lina; Racette, Susan B.; Anderson Spearie, Catherine L.; Ostlund, Richard E.

    2009-01-01

    Dietary phytosterols inhibit intestinal cholesterol absorption and regulate whole body cholesterol excretion and balance. However, they are biochemically heterogeneous and a portion is glycosylated in some foods with unknown effects on biological activity. We tested the hypothesis that phytosterol glycosides reduce cholesterol absorption in humans. Phytosterol glycosides were extracted and purified from soy lecithin in a novel two-step process. Cholesterol absorption was measured in a series of three single-meal tests given at intervals of 2 wk to each of 11 healthy subjects. In a randomized crossover design, participants received ∼300 mg of added phytosterols in the form of phytosterol glycosides or phytosterol esters, or placebo in a test breakfast also containing 30 mg cholesterol-d7. Cholesterol absorption was estimated by mass spectrometry of plasma cholesterol-d7 enrichment 4–5 days after each test. Compared with the placebo test, phytosterol glycosides reduced cholesterol absorption by 37.6 ± 4.8% (P lecithin are bioactive in humans and should be included in methods of phytosterol analysis and tables of food phytosterol content. PMID:19246636

  4. Absorption Mode FT-ICR Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Donald F.; Kilgour, David P.; Konijnenburg, Marco; O' Connor, Peter B.; Heeren, Ronald M.

    2013-12-03

    Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here we present the first use of absorption mode for Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image and then these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode ?Datacubes? for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.

  5. Simulation of absorption refrigeration system for automobile application

    Directory of Open Access Journals (Sweden)

    Ramanathan Anand

    2008-01-01

    Full Text Available An automotive air-conditioning system based on absorption refrigeration cycle has been simulated. This waste heat driven vapor absorption refrigeration system is one alternate to the currently used vapour compression refrigeration system for automotive air-conditioning. Performance analysis of vapor absorption refrigeration system has been done by developing a steady-state simulation model to find the limitation of the proposed system. The water-lithium bromide pair is used as a working mixture for its favorable thermodynamic and transport properties compared to the conventional refrigerants utilized in vapor compression refrigeration applications. The pump power required for the proposed vapor absorption refrigeration system was found lesser than the power required to operate the compressor used in the conventional vapor compression refrigeration system. A possible arrangement of the absorption system for automobile application is proposed.

  6. Acoustic absorption behaviour of an open-celled aluminium foam

    CERN Document Server

    Han Fu Sheng; Zhao Yu Yuan; Gibbs, B

    2003-01-01

    Metal foams, especially close-celled foams, are generally regarded as poor sound absorbers. This paper studies the sound absorption behaviour of the open-celled Al foams manufactured by the infiltration process, and the mechanisms involved. The foams show a significant improvement in sound absorption compared with close-celled Al foams, because of their high flow resistance. The absorption performance can be further enhanced, especially at low frequencies, if the foam panel is backed by an appropriate air gap. Increasing the air-gap depth usually increases both the height and the width of the absorption peak and shifts the peak towards lower frequencies. The foam samples with the smallest pore size exhibit the best absorption capacities when there is no air gap, whereas those with medium pore sizes have the best overall performance when there is an air gap. The typical maximum absorption coefficient, noise reduction coefficient and half-width of the absorption peak are 0.96-0.99, 0.44-0.62 and 1500-3500 Hz, r...

  7. Absorption of ultraviolet radiation by antarctic phytoplankton

    Energy Technology Data Exchange (ETDEWEB)

    Vernet, M.; Mitchell, B.G. (Univ. of California-San Diego, La Jolla (United States))

    1990-01-09

    Antarctic phytoplankton contain UV-absorbing compounds that may block damaging radiation. Compounds that absorb from 320-340 nm were observed in spectral absorption of both particulates and in methanol extracts of the particulates. The decrease in the total concentration of these UV compounds with respect to chlorophyll a, as measured by the ratio of in vitro absorption at 335 nm to absorption at 665 nm is variable and decreases with depth. We observed up to 5-fold decrease in this ratio for samples within the physically mixes surface layer. The absorption of UV radiation in methanol extracts, which peaks from 320 to 340 nm, may be composed of several compounds. Shifts in peak absorption with depth (for example, from 331 nm at surface to 321 nm at 75 m), may be interpreted as a change in composition. Ratios of protective yellow xanthophylls (diadinoxanthin + diatoxanthin) to photosynthetic fucoxanthin-like pigments have highest values in surface waters. As these pigments also absorb in the near UV, their function might extend to protection as well as utilization of UV radiation for photosynthesis. We document strong absorption in the UV from 320-330 nm for Antarctic marine particulates. Below this region of the solar energy spectrum, absolute energy levels of incident radiation drop off dramatically. Only wavelengths shorter than about 320 nm will be significantly enhanced due to ozone depletion. If the absorption we observed serves a protective role for phytoplankton photosynthesis, it appears the peak band is in the region where solar energy increases rapidly, and not in the region where depletion would cause significant variations in absolute flux.

  8. Infrared absorption in PbTe single crystals

    International Nuclear Information System (INIS)

    Kudykina, T.A.

    1982-01-01

    A group-theoretical analysis is conducted to select rules for optical transitions between bands in PbTe single crystals. It is shown that transitions between valence bands which are near a forbidden band are also forbidden. The extra absorption observed in p-PbTe and p-Pbsub(1-x)Snsub(x)Te in the region between the self-absorption edge and the free-carrier absorption edge is probably connected with transitions between one of valence bands and the p-state of the impurity

  9. Optical absorption in a thin nickel wire

    OpenAIRE

    INAGAKI, Takashi; Goudonnet, J.P.; ARAKAWA, E.T.

    1986-01-01

    Absorption of a 633-nm phonton in a cylindrical nickel wire with diameter 13 m was measured by a photoacoustic method as a function of angle of phonton incidence . A good photoacoustic signal was obtained with a 6-m W He-Ne laser as a light source without employing focusing optics. The absorption measured for p-polarized phontons was found to be in good agreement with geometrical optics calculation. For s-polarized light, however, significant excess absorption was found for >35.

  10. Temperature-dependent optical absorption of SrTiO3

    International Nuclear Information System (INIS)

    Kok, Dirk J.; Irmscher, Klaus; Naumann, Martin; Guguschev, Christo; Galazka, Zbigniew; Uecker, Reinhard

    2015-01-01

    The optical absorption edge and near infrared absorption of SrTiO 3 were measured at temperatures from 4 to 1703 K. The absorption edge decreases from 3.25 eV at 4 K to 1.8 eV at 1703 K and is extrapolated to approximately 1.2 eV at the melting point (2350 K). The transmission in the near IR decreases rapidly above 1400 K because of free carrier absorption and is about 50% of the room temperature value at 1673 K. The free carriers are generated by thermal excitation of electrons over the band gap and the formation of charged vacancies. The observed temperature-dependent infrared absorption can be well reproduced by a calculation based on simple models for the intrinsic free carrier concentration and the free carrier absorption coefficient. The measured red shift of the optical absorption edge and the rising free carrier absorption strongly narrow the spectral range of transmission and impede radiative heat transport through the crystal. These effects have to be considered in high temperature applications of SrTiO 3 -based devices, as the number of free carriers rises considerably, and in bulk crystal growth to avoid growth instabilities. Temperature dependent optical absorption edge of SrTiO 3 , measured, fitted, and extrapolated to the melting point. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Laser Absorption by Over-Critical Plasmas

    Science.gov (United States)

    May, J.; Tonge, J.; Fiuza, F.; Fonseca, R. A.; Silva, L. O.; Mori, W. B.

    2015-11-01

    Absorption of high intensity laser light by matter has important applications to emerging sciences and technology, such as Fast Ignition ICF and ion acceleration. As such, understanding the underlying mechanisms of this absorption is key to developing these technologies. Critical features which distinguish the interaction of high intensity light - defined here as a laser field having a normalized vector potential greater than unity - are that the reaction of the material to the fields results in sharp high-density interfaces; and that the movement of the electrons is in general relativistic, both in a fluid and a thermal sense. The results of these features are that the absorption mechanisms are qualitatively distinct from those at lower intensities. We will review previous work, by our group and others, on the absorption mechanisms, and highlight current research. We will show that the standing wave structure of the reflected laser light is key to particle dynamics for normally incident lasers. The authors acknowledge the support of the Department of Energy under contract DE-NA 0001833 and the National Science Foundation under contract ACI 1339893.

  12. Water absorption of superabsorbent polymers in a cementitious environment

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede

    2011-01-01

    This paper focuses on the water absorption of superabsorbent polymers in a cementitious environment. The paper discusses different techniques to measure the water absorption capacity, and in particular it describes a technique which enables a simple and quick estimation of the water absorption...... capacity in a cementitious environment. The challenges met in defining the concept of water absorption capacity are treated, and the appropriateness of different types of superabsorbent polymers is also briefly dealt with. The concept “water absorption capacity” and its measurement seem straightforwardly...... simple, but a closer examination of the topic discloses many, significant difficulties. However, given proper cautiousness it is possible both to quickly estimate the water absorption capacity through a simple measurement as well as to examine how it will be influenced by different factors....

  13. Total photon absorption

    International Nuclear Information System (INIS)

    Carlos, P.

    1985-01-01

    Experimental methods using real photon beams for measurements of total photonuclear absorption cross section σ(Tot : E/sub γ/) are recalled. Most recent σ(Tot : E/sub γ/)results for complex nuclei and in the nucleon resonance region are presented

  14. Unveiling the Microfoundations of Absorptive Capacity

    DEFF Research Database (Denmark)

    Distel, Andreas Philipp

    2017-01-01

    to absorptive capacity at the organizational level and that this relationship is mediated through a microlevel process. The findings reveal that knowledge workers’ cognitive process of perspective taking and their creative behavior are important microfoundations of absorptive capacity. Moreover, the results...... emphasize the critical role of key employees in explaining firm-level heterogeneity in building organizational capabilities....

  15. Sustainable Absorption Panels from Agricultural Wastes

    Directory of Open Access Journals (Sweden)

    Ismail F.Z.

    2014-01-01

    Full Text Available Noise has become a serious environmental problem and there are demands for alternative sustainable materials which capable to reduce the noise level at various frequency ranges. Therefore, the aim of this research is to study the potential of turning the agricultural waste and waste paper into a sound absorption panel. For the purpose of this study, combination of two materials was under studied; coconut coir fibre from agriculture waste and shredded waste paper from the office. There were two main objective of the research; first is to develop absorption panels from coconut coir powder that available locally with a combination of shredded paper at different percentage of mixture. Second objective is to identify the absorption rate of the panels. The study encompasses the fabrication of the particle board using the coconut husk powder mix with shredded waste paper and using the gypsum powder as the binder for the two materials. Four acoustic panels of size 0.5m x 0.5m and 0.012 m thick were fabricated with different mix ratio; 25% of coconut coir powder mixed with 75% of shredded waste papers for sample 1, 50% both of the material for sample 2, 75% of coconut coir powder mixed with 25% of shredded waste paper for sample 3, and lastly 100% of coconut coir powder for sample 4. The absorption coefficient of the panels was tested in a reverberation chamber and in accordance with ISO 354:1985 standards. Based on the results, sample 1 gave the highest absorption coefficient compared to sample 2, 3 and 4. It can be concluded that the acoustic panel made from a mixture of 25% coconut coir powder with 75% shredded waste paper provided higher absorption coefficient compared to the performance of the other samples. This might be caused by the size of the coir powder which is very small, creating less void space in between the panel and thus causing it to absorb less sound. Since sound absorption is very much affected by the availability of void space of

  16. Absorption spectrum of Iodine around 5915 A

    International Nuclear Information System (INIS)

    1990-01-01

    The iodine absorption spectrum around 5915 A is of interest for many authors especially the hyperfine structure of the iodine line. Lodine absorption spectrum was obtained due to the interaction of iodine vapour with dye laser [(R6G) (0.5A) scanning range around 5915 A] which is pumped by(Ar + )laser absorption spectrum. The decrease in the peak of the transmission line around 5915 A shows the signal futher decreased by heating the iodine cell. This analysis has been done using a monochromator

  17. Optical absorption in a thin nickel wire

    International Nuclear Information System (INIS)

    Inagaki, T.; Goudonnet, J.P.; Arakawa, E.T.

    1986-01-01

    Absorption of a 633-nm photon in a cylindrical nickel wire with diameter 13 μm was measured by a photoacoustic method as a function of angle of photon incidence theta. A good photoacoustic signal was obtained with a 6-mW He-Ne laser as a light source without employing focusing optics. The absorption measured for p-polarized photons was found to be in good agreement with geometrical optics calculation. For s-polarized light, however, significant excess absorption was found for theta > 35 0

  18. Absorption spectrum of DNA for wavelengths greater than 300 nm

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Griffin, K.P.

    1981-01-01

    Although DNA absorption at wavelengths greater than 300 nm is much weaker than that at shorter wavelengths, this absorption seems to be responsible for much of the biological damage caused by solar radiation of wavelengths less than 320 nm. Accurate measurement of the absorption spectrum of DNA above 300 nm is complicated by turbidity characteristic of concentrated solutions of DNA. We have measured the absorption spectra of DNA from calf thymus, Clostridium perfringens, Escherichia coli, Micrococcus luteus, salmon testis, and human placenta using procedures which separate optical density due to true absorption from that due to turbidity. Above 300 nm, the relative absorption of DNA increases as a function of guanine-cytosine content, presumably because the absorption of guanine is much greater than the absorption of adenine at these wavelengths. This result suggests that the photophysical processes which follow absorption of a long-wavelength photon may, on the average, differ from those induced by shorter-wavelength photons. It may also explain the lower quantum yield for the killing of cells by wavelengths above 300 nm compared to that by shorter wavelengths

  19. In vivo analysis of supersaturation/precipitation/absorption behavior after oral administration of pioglitazone hydrochloride salt; determinant site of oral absorption.

    Science.gov (United States)

    Tanaka, Yusuke; Sugihara, Masahisa; Kawakami, Ayaka; Imai, So; Itou, Takafumi; Murase, Hirokazu; Saiki, Kazunori; Kasaoka, Satoshi; Yoshikawa, Hiroshi

    2017-08-30

    The purpose of this study was to evaluate in vivo supersaturation/precipitation/absorption behavior in the gastrointestinal (GI) tract based on the luminal concentration-time profiles after oral administration of pioglitazone (PG, a highly permeable lipophilic base) and its hydrochloride salt (PG-HCl) to rats. In the in vitro precipitation experiment in the classic closed system, while the supersaturation was stable in the simulated gastric condition, PG drastically precipitated in the simulated intestinal condition, particularly at a higher initial degree of supersaturation. Nonetheless, a drastic and moderate improvement in absorption was observed in vivo at a low and high dose of PG-HCl, respectively. Analysis based on the luminal concentration of PG after oral administration of PG-HCl at a low dose revealed that most of the dissolved PG emptied from the stomach was rapidly absorbed before its precipitation in the duodenum. At a high dose of PG-HCl, PG partly precipitated in the duodenum but was absorbed to some extent. Therefore, the extent of the absorption was mainly dependent on the duodenal precipitation behavior. Furthermore, a higher-than expected absorption after oral administration of PG-HCl from in vitro precipitation study may be due to the absorption process in the small intestine, which suppresses the precipitation by removal of the drug. This study successfully clarify the impact of the absorption process on the supersaturation/precipitation/absorption behavior and key absorption site for a salt formulation of a highly permeable lipophilic base based on the direct observation of in vivo luminal concentration. Our findings may be beneficial in developing an ideal physiologically based pharmacokinetic model and in vitro predictive dissolution tools and/or translating the in silico and in vitro data to the in vivo outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. OZONE ABSORPTION IN RAW WATERS

    Directory of Open Access Journals (Sweden)

    LJILJANA TAKIĆ

    2008-03-01

    Full Text Available The ozone absorption in raw water entering the main ozonization step at the Belgrade drinking water supply plant was investigated in a continuous stirred tank reactor (CSTR. A slow chemical reaction rate of dissolved ozone and pollutants present in raw water have been experimentally determined. The modified Hatta number was defined and calculated as a criterion which determines whether and to which extent the reactions of ozone and pollutants influence the rate of the pure physical ozone absorption.

  1. Enhanced Water Vapor Absorption within Tropospheric Clouds: A Partial Explanation for Anomalous Absorption

    Science.gov (United States)

    Crisp, David; Zuffada, Cinzia

    1996-01-01

    Comparisons between solar flux measurements and predictions obtained from theoretical radiative transfer models indicate that most of these models underestimate the globally averaged solar energy absorbed by cloudy atmospheres by up to 25Wm&sup-2;.The origin of this anomalous absorption has not yet been established, but it has been attributed to a variety of sources including oversimplified or missing physical processes in the existing models, uncertainties in the input data, and even measurement errors. We used a sophisticated atmospheric radiative transfer model to provide improved constraints on the physical processes that contribute to the absorption of solar radiation by Earth's atmosphere. The results are described herein.

  2. Zinc absorption in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Valberg, L.S.; Flanagan, P.R.; Kertesz, A.; Bondy, D.C.

    1986-01-01

    Zinc absorption was measured in 29 patients with inflammatory bowel disease and a wide spectrum of disease activity to determine its relationship to disease activity, general nutritional state, and zinc status. Patients with severe disease requiring either supplementary oral or parenteral nutrition were excluded. The mean 65ZnCl2 absorption, in the patients, determined using a 65Zn and 51Cr stool-counting test, 45 +/- 17% (SD), was significantly lower than the values, 54 +/- 16%, in 30 healthy controls, P less than 0.05. Low 65ZnCl2 absorption was related to undernutrition, but not to disease activity in the absence of undernutrition or to zinc status estimated by leukocyte zinc measurements. Mean plasma zinc or leukocyte zinc concentrations in patients did not differ significantly from controls, and only two patients with moderate disease had leukocyte zinc values below the 5th percentile of normal. In another group of nine patients with inflammatory bowel disease of mild-to-moderate severity and minimal nutritional impairment, 65Zn absorption from an extrinsically labeled turkey test meal was 31 +/- 10% compared to 33 +/- 7% in 17 healthy controls, P greater than 0.1. Thus, impairment in 65ZnCl2 absorption in the patients selected for this study was only evident in undernourished persons with moderate or severe disease activity, but biochemical evidence of zinc deficiency was uncommon, and clinical features of zinc depletion were not encountered

  3. An in silico skin absorption model for fragrance materials.

    Science.gov (United States)

    Shen, Jie; Kromidas, Lambros; Schultz, Terry; Bhatia, Sneha

    2014-12-01

    Fragrance materials are widely used in cosmetics and other consumer products. The Research Institute for Fragrance Materials (RIFM) evaluates the safety of these ingredients and skin absorption is an important parameter in refining systemic exposure. Currently, RIFM's safety assessment process assumes 100% skin absorption when experimental data are lacking. This 100% absorption default is not supportable and alternate default values were proposed. This study aims to develop and validate a practical skin absorption model (SAM) specific for fragrance material. It estimates skin absorption based on the methodology proposed by Kroes et al. SAM uses three default absorption values based on the maximum flux (J(max)) - namely, 10%, 40%, and 80%. J(max) may be calculated by using QSAR models that determine octanol/water partition coefficient (K(ow)), water solubility (S) and permeability coefficient (K(p)). Each of these QSAR models was refined and a semi-quantitative mechanistic model workflow is presented. SAM was validated with a large fragrance-focused data set containing 131 materials. All resulted in predicted values fitting the three-tiered absorption scenario based on Jmax ranges. This conservative SAM may be applied when fragrance material lack skin absorption data. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Acoustic absorption behaviour of an open-celled aluminium foam

    International Nuclear Information System (INIS)

    Han Fusheng; Seiffert, Gary; Zhao Yuyuan; Gibbs, Barry

    2003-01-01

    Metal foams, especially close-celled foams, are generally regarded as poor sound absorbers. This paper studies the sound absorption behaviour of the open-celled Al foams manufactured by the infiltration process, and the mechanisms involved. The foams show a significant improvement in sound absorption compared with close-celled Al foams, because of their high flow resistance. The absorption performance can be further enhanced, especially at low frequencies, if the foam panel is backed by an appropriate air gap. Increasing the air-gap depth usually increases both the height and the width of the absorption peak and shifts the peak towards lower frequencies. The foam samples with the smallest pore size exhibit the best absorption capacities when there is no air gap, whereas those with medium pore sizes have the best overall performance when there is an air gap. The typical maximum absorption coefficient, noise reduction coefficient and half-width of the absorption peak are 0.96-0.99, 0.44-0.62 and 1500-3500 Hz, respectively. The sound dissipation mechanisms in the open-celled foams are principally viscous and thermal losses when there is no air-gap backing and predominantly Helmholtz resonant absorption when there is an air-gap backing

  5. The low-ion QSO absorption-line systems

    International Nuclear Information System (INIS)

    Lanzetta, K.M.

    1988-01-01

    Various techniques are used to investigate the class of QSO absorption-line systems that exhibit low-ion absorption lines. Four separate investigations are conducted as follows: Spectroscopy of 32 QSOs at red wavelengths is presented and used to investigate intermediate-redshift MgII absorption. A total of 22 Mg II doublets are detected, from which properties of the Mg II absorbers are derived. Marginal evidence for intrinsic evolution of the number density of the Mg II absorbers with redshift is found. The data are combined with previous observations of C IV and C II seen in the same QSOs at blue wavelengths, and the properties of Mg II- and C IV-selected systems are compared. A sample is constructed of 129 QSOs for which are available published data suitable for detecting absorption-line systems that are optically thick to Lyman continuum radiation. A total of 53 such Lyman-limit systems are found, from which properties of the Lyman-limit systems are derived. It is found that the rate of incidence of the systems does not strongly evolved with redshift. This result is contrasted with the evolution found previously for systems selected on the basis of Mg II absorption. Spectroscopy at red wavelengths of eight QSOs with known damped Lyα absorption systems is presented. Spectroscopic and spectrophotometric observations aimed at detecting molecular hydrogen and dust in the z = 2.796 damped Lyα absorber toward Q1337 + 113 are presented

  6. Chemical Absorption Materials

    DEFF Research Database (Denmark)

    Thomsen, Kaj

    2011-01-01

    Chemical absorption materials that potentially can be used for post combustion carbon dioxide capture are discussed. They fall into five groups, alkanolamines, alkali carbonates, ammonia, amino acid salts, and ionic liquids. The chemistry of the materials is discussed and advantages and drawbacks...

  7. Phytosterol glycosides reduce cholesterol absorption in humans.

    Science.gov (United States)

    Lin, Xiaobo; Ma, Lina; Racette, Susan B; Anderson Spearie, Catherine L; Ostlund, Richard E

    2009-04-01

    Dietary phytosterols inhibit intestinal cholesterol absorption and regulate whole body cholesterol excretion and balance. However, they are biochemically heterogeneous and a portion is glycosylated in some foods with unknown effects on biological activity. We tested the hypothesis that phytosterol glycosides reduce cholesterol absorption in humans. Phytosterol glycosides were extracted and purified from soy lecithin in a novel two-step process. Cholesterol absorption was measured in a series of three single-meal tests given at intervals of 2 wk to each of 11 healthy subjects. In a randomized crossover design, participants received approximately 300 mg of added phytosterols in the form of phytosterol glycosides or phytosterol esters, or placebo in a test breakfast also containing 30 mg cholesterol-d7. Cholesterol absorption was estimated by mass spectrometry of plasma cholesterol-d7 enrichment 4-5 days after each test. Compared with the placebo test, phytosterol glycosides reduced cholesterol absorption by 37.6+/-4.8% (Pphytosterol esters 30.6+/-3.9% (P=0.0001). These results suggest that natural phytosterol glycosides purified from lecithin are bioactive in humans and should be included in methods of phytosterol analysis and tables of food phytosterol content.

  8. Absorption coefficients of silicon: A theoretical treatment

    Science.gov (United States)

    Tsai, Chin-Yi

    2018-05-01

    A theoretical model with explicit formulas for calculating the optical absorption and gain coefficients of silicon is presented. It incorporates direct and indirect interband transitions and considers the effects of occupied/unoccupied carrier states. The indirect interband transition is calculated from the second-order time-independent perturbation theory of quantum mechanics by incorporating all eight possible routes of absorption or emission of photons and phonons. Absorption coefficients of silicon are calculated from these formulas. The agreements and discrepancies among the calculated results, the Rajkanan-Singh-Shewchun (RSS) formula, and Green's data are investigated and discussed. For example, the RSS formula tends to overestimate the contributions of indirect transitions for cases with high photon energy. The results show that the state occupied/unoccupied effect is almost negligible for silicon absorption coefficients up to the onset of the optical gain condition where the energy separation of Quasi-Femi levels between electrons and holes is larger than the band-gap energy. The usefulness of using the physics-based formulas, rather than semi-empirical fitting ones, for absorption coefficients in theoretical studies of photovoltaic devices is also discussed.

  9. Frenkel defect absorption on dislocations and dislocation discharge rate. Modeling determination of the absorption zone

    International Nuclear Information System (INIS)

    Mikhlin, Eh.Ya.

    1988-01-01

    A situation connected with the fact that evaluations of dislocation discharge strength which somehow or other are based on the elasticity theory in the dislocation nucleus or near it, do not lead to results complying with experimental data, is discussed. Bases of the alternative approach to this problem consisting in direct investigation into the process of Frenkel defect absorption on dislocation by its computerized simulation at the microscopic level are also presented. Methods of investigation and results are described using α dislocation in iron-alpha as an example. The concept of zones of vacancy and interstitial atom absorption on dislocation is discussed. It is shown that a spontaneous transition, performed by any of these defects near a dislocation is not always identical to absorption and usually appears to be only a part of a multistage process leading to the defect disappearance. Potential relief characteristics for vacancy movement near the dislocation are found. An area wide enough in a transverse direction is found around the dislocation. Vacncies reaching this area can be easily transported to places of their disappearance. Therefore the vacancy entry to this area is equivalent to the absorption. the procedure of simulating the atomic structure of a crystallite containing a dislocation with a step is described. Positions from which these defects perform spontaneous transitions, reaching the disappearance places are found on the dislocation near the step

  10. Far-wing absorption in Na-Ar collision

    International Nuclear Information System (INIS)

    Kulander, K.C.

    1985-01-01

    Collision-induced absorption and emission at wavelengths well removed from line center play important roles in many atomic and molecular processes. The authors have developed the theory and computer codes to calculate exact quantum mechanical cross sections for these optical and radiative collisions between atoms. The authors also have produced a quasi-classical model that can efficiently generate accurate absorption cross sections. This model cannot, however, give branching ratios for the final-state populations. Their codes and model can be used to study the propagation of nearly resonant light through gaseous media and to calculate accurate gain and absorption cross sections for the far wings of atomic transitions. The authors have used their theory to study the collision-induced absorption by sodium in argon for wavelengths in the vicinity of the resonance lines D 1 and D 2

  11. Linear absorptive dielectrics

    Science.gov (United States)

    Tip, A.

    1998-06-01

    Starting from Maxwell's equations for a linear, nonconducting, absorptive, and dispersive medium, characterized by the constitutive equations D(x,t)=ɛ1(x)E(x,t)+∫t-∞dsχ(x,t-s)E(x,s) and H(x,t)=B(x,t), a unitary time evolution and canonical formalism is obtained. Given the complex, coordinate, and frequency-dependent, electric permeability ɛ(x,ω), no further assumptions are made. The procedure leads to a proper definition of band gaps in the periodic case and a new continuity equation for energy flow. An S-matrix formalism for scattering from lossy objects is presented in full detail. A quantized version of the formalism is derived and applied to the generation of Čerenkov and transition radiation as well as atomic decay. The last case suggests a useful generalization of the density of states to the absorptive situation.

  12. Coherent enhancement of resonance-mediated multiphoton absorption

    International Nuclear Information System (INIS)

    Zhang, Shian; Zhang, Hui; Jia, Tianqing; Wang, Zugeng; Sun, Zhenrong

    2010-01-01

    In this paper, we theoretically investigate the coherent enhancement of resonance-mediated (2+2) four-photon absorption. It is found that by shaping the spectral phase with a π phase step, the resonance-mediated (2+2) four-photon transition probability can be enhanced. Furthermore, the coherent enhancement dependences on the detuning between the two two-photon absorptions, laser spectral bandwidth and laser centre frequency are explicitly discussed and analysed. We believe these theoretical results may play an important role in enhancing more complex resonance-mediated multiphoton absorption processes.

  13. The Driving Forces of Subsidiary Absorptive Capacity

    DEFF Research Database (Denmark)

    Schleimer, Stephanie C.; Pedersen, Torben

    2013-01-01

    The study investigates how a multinational corporation (MNC) can promote the absorptive capacity of its subsidiaries. The focus is on what drives the MNC subsidiary's ability to absorb marketing strategies that are initiated by the MNC parent, as well as how the subsidiary enacts on this absorptive...... as a purposeful response to this dual embeddedness. An analysis of marketing strategy absorptions undertaken by 213 subsidiaries reveals that MNCs can assist their subsidiaries to compete in competitive and dynamic focal markets by forming specific organizational mechanisms that are conducive to the development...

  14. Analytic descriptions of ion cyclotron absorption

    International Nuclear Information System (INIS)

    Bers, A.; Francis, G.; Fuchs, V.; Lashmore-Davies, C.N.; Ram, A.K.

    1987-05-01

    Analysis of energy propagation and absorption in ion-cyclotron heating of tokamak plasmas has relied on numerical solutions of fourth (and sixth) order differential equations for slab models of the plasma (poloidal) cross section. Realistic two-dimensional and fully toroidal geometry analyses would become quite unwieldy. It is shown here that the analysis of the slab model can be simplified considerably. A first-order differential equation is shown to describe the transmission coefficient for the fast wave, and it is solved analytically. A second order differential equation is shown to adequately describe both transmission and reflection. Conditions for ion absorption or mode conversion are derived. Including toroidal effects in propagation, conditions for electron absorption on the mode-converted ion-Bernstein waves are also described analytically

  15. Absorption spectra of AA-stacked graphite

    International Nuclear Information System (INIS)

    Chiu, C W; Lee, S H; Chen, S C; Lin, M F; Shyu, F L

    2010-01-01

    AA-stacked graphite shows strong anisotropy in geometric structures and velocity matrix elements. However, the absorption spectra are isotropic for the polarization vector on the graphene plane. The spectra exhibit one prominent plateau at middle energy and one shoulder structure at lower energy. These structures directly reflect the unique geometric and band structures and provide sufficient information for experimental fitting of the intralayer and interlayer atomic interactions. On the other hand, monolayer graphene shows a sharp absorption peak but no shoulder structure; AA-stacked bilayer graphene has two absorption peaks at middle energy and abruptly vanishes at lower energy. Furthermore, the isotropic features are expected to exist in other graphene-related systems. The calculated results and the predicted atomic interactions could be verified by optical measurements.

  16. Multi-spectral optical absorption in substrate-free nanowire arrays

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Junpeng; Chia, Andrew; Boulanger, Jonathan; LaPierre, Ray, E-mail: lapierr@mcmaster.ca [Department of Engineering Physics, McMaster University, 1280 Main St. West, Hamilton, Ontario L8S 4L7 (Canada); Dhindsa, Navneet; Khodadad, Iman; Saini, Simarjeet [Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave West, Waterloo, Ontario N2L 3G1 (Canada); Waterloo Institute of Nanotechnology, University of Waterloo, 200 University Ave West, Waterloo, Ontario N2L 3G1 (Canada)

    2014-09-22

    A method is presented of fabricating gallium arsenide (GaAs) nanowire arrays of controlled diameter and period by reactive ion etching of a GaAs substrate containing an indium gallium arsenide (InGaP) etch stop layer, allowing the precise nanowire length to be controlled. The substrate is subsequently removed by selective etching, using the same InGaP etch stop layer, to create a substrate-free GaAs nanowire array. The optical absorptance of the nanowire array was then directly measured without absorption from a substrate. We directly observe absorptance spectra that can be tuned by the nanowire diameter, as explained with rigorous coupled wave analysis. These results illustrate strong optical absorption suitable for nanowire-based solar cells and multi-spectral absorption for wavelength discriminating photodetectors. The solar-weighted absorptance above the bandgap of GaAs was 94% for a nanowire surface coverage of only 15%.

  17. Calcium absorption from fortified ice cream formulations compared with calcium absorption from milk.

    Science.gov (United States)

    van der Hee, Regine M; Miret, Silvia; Slettenaar, Marieke; Duchateau, Guus S M J E; Rietveld, Anton G; Wilkinson, Joy E; Quail, Patricia J; Berry, Mark J; Dainty, Jack R; Teucher, Birgit; Fairweather-Tait, Susan J

    2009-05-01

    Optimal bone mass in early adulthood is achieved through appropriate diet and lifestyle, thereby protecting against osteoporosis and risk of bone fracture in later life. Calcium and vitamin D are essential to build adequate bones, but calcium intakes of many population groups do not meet dietary reference values. In addition, changes in dietary patterns are exacerbating the problem, thereby emphasizing the important role of calcium-rich food products. We have designed a calcium-fortified ice cream formulation that is lower in fat than regular ice cream and could provide a useful source of additional dietary calcium. Calcium absorption from two different ice cream formulations was determined in young adults and compared with milk. Sixteen healthy volunteers (25 to 45 years of age), recruited from the general public of The Netherlands, participated in a randomized, reference-controlled, double-blind cross-over study in which two test products and milk were consumed with a light standard breakfast on three separate occasions: a standard portion of ice cream (60 g) fortified with milk minerals and containing a low level (3%) of butter fat, ice cream (60 g) fortified with milk minerals and containing a typical level (9%) of coconut oil, and reduced-fat milk (1.7% milk fat) (200 mL). Calcium absorption was measured by the dual-label stable isotope technique. Effects on calcium absorption were evaluated by analysis of variance. Fractional absorption of calcium from the 3% butterfat ice cream, 9% coconut oil ice cream, and milk was 26%+/-8%, 28%+/-5%, and 31%+/-9%, respectively, and did not differ significantly (P=0.159). Results indicate that calcium bioavailability in the two calcium-fortified ice cream formulations used in this study is as high as milk, indicating that ice cream may be a good vehicle for delivery of calcium.

  18. Systematic review: Helicobacter pylori infection and impaired drug absorption.

    Science.gov (United States)

    Lahner, E; Annibale, B; Delle Fave, G

    2009-02-15

    Impaired acid secretion may affect drug absorption and may be consequent to corporal Helicobacter pylori-gastritis, which may affect the absorption of orally administered drugs. To focus on the evidence of impaired drug absorption associated with H. pylori infection. Data sources were the systematic search of MEDLINE/EMBASE/SCOPUS databases (1980-April 2008) for English articles using the keywords: drug malabsorption/absorption, stomach, Helicobacter pylori, gastritis, gastric acid, gastric pH, hypochlorhydria, gastric hypoacidity. Study selection was made from 2099 retrieved articles, five studies were identified. Data were extracted from selected papers, investigated drugs, study type, main features of subjects, study design, intervention type and results were extracted. In all, five studies investigated impaired absorption of l-dopa, thyroxine and delavirdine in H. pylori infection. Eradication treatment led to 21-54% increase in l-dopa in Parkinson's disease. Thyroxine requirement was higher in hypochlorhydric goitre with H. pylori-gastritis and thyrotropin levels decreased by 94% after treatment. In H. pylori- and HIV-positive hypochlorhydric subjects, delavirdine absorption increased by 57% with orange juice administration and by 150% after eradication. A plausible mechanism of impaired drug absorption is decreased acid secretion in H. pylori-gastritis patients. Helicobacter pylori infection and hypochlorhydria should be considered in prescribing drugs the absorption of which is potentially affected by intragastric pH.

  19. Wine absorption by cork stoppers research in foods

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Adrados, J. R.; Gonzalez-Hernandez, F.; Garcia de Ceca, J. L.; Caceres-Esteban, M. J.; Garcia-Vallejo, M. C.

    2008-07-01

    To evaluate the magnitude of wine absorption by cork under conditions as close to reality as possible and its evolution in time, ready-to-use natural cork stoppers and ''1+1'' cork stoppers were used to close bottles filled with red wine. Stoppers were removed after 3, 6, 12 and 24 months of contact to determine absorption of liquid and liquid progression along the lateral surface of the cork stopper.Variation of absorption with contact time was studied by adjusting the model Absorption = a {radical} t(R{sup 2}: 82.19 - 93.63%). A scheme of the evolution of wine absorption with time is proposed, differentiating liquid flow along cork-glass interface, diffusion in cell walls and liquid flow through the cell lumens. In conditions of use, a value of 4.48.10{sup 1}3 m{sup 2} s{sup -}1 was obtained for non-radial diffusion coefficient (D). (Author) 13 refs.

  20. Exercise, Insulin Absorption Rates, and Artificial Pancreas Control

    Science.gov (United States)

    Frank, Spencer; Hinshaw, Ling; Basu, Rita; Basu, Ananda; Szeri, Andrew J.

    2016-11-01

    Type 1 Diabetes is characterized by an inability of a person to endogenously produce the hormone insulin. Because of this, insulin must be injected - usually subcutaneously. The size of the injected dose and the rate at which the dose reaches the circulatory system have a profound effect on the ability to control glucose excursions, and therefore control of diabetes. However, insulin absorption rates via subcutaneous injection are variable and depend on a number of factors including tissue perfusion, physical activity (vasodilation, increased capillary throughput), and other tissue geometric and physical properties. Exercise may also have a sizeable effect on the rate of insulin absorption, which can potentially lead to dangerous glucose levels. Insulin-dosing algorithms, as implemented in an artificial pancreas controller, should account accurately for absorption rate variability and exercise effects on insulin absorption. The aforementioned factors affecting insulin absorption will be discussed within the context of both fluid mechanics and data driven modeling approaches.

  1. Absorption of medicamental iron and iron from food

    International Nuclear Information System (INIS)

    Reizenstein, P.; Carlmark, B.; Ehn, L.; Forsberg, K.; Hoeglund, S.; Terpstra, T.

    1976-01-01

    Methods are reviewed for the measurement of iron absorption. The chemical balance method has been almost entirely supplanted by radioisotope methods, which include notably whole-body counting and measurement of incorporation of radioiron into red cells. A survey is also given of the various conditions that influence iron absorption, including chemical form of iron, amount of iron, accompanying diet. Absorption tests must be conducted under relevant conditions. (author)

  2. Acoustic absorption of natural gas compression facility enclosures

    Energy Technology Data Exchange (ETDEWEB)

    Lassen, P.; Wong, G. [Noise Management Ltd., Calgary, AB (Canada)

    2009-07-01

    Noise sources at gas compressor facilities include the enclosure/building housing a gas engine and compressor, the ventilation openings, doors and windows for the enclosure, the engine air intake and exhaust, and a cooler. Accurate predictions of the noise levels inside the enclosure, the breakout noise from open windows and doors and ventilation, as well as the transmission through the walls, is necessary in order to determine cost effective noise mitigation for the facility. In order to accurately predict the sound breakout from these facilities it is necessary to know the acoustic absorption of the interior of these equipment enclosures. Although the acoustic absorption data of the wall systems may be available, the absorption attributable to the non-enclosure surfaces, the equipment and fittings, is not usually known and is difficult to predict. Since piping, instrumentation and mechanical equipment often take on a typical arrangement, shape, volumetric density and material composition, it is useful to know the typical acoustic absorption attributable to these items. In this study, reverberation time (RT) measurements were taken at 2 decommissioned gas compressor facilities in order to determine the absorption characteristics of the enclosure. The RT was measured according to ASTM C423-02a. The overall absorption coefficient of a compressor enclosure with a solid liner was found to be similar to that of steel decking. Fittings within the enclosure did not increase the high frequency absorption of the enclosure. It was concluded that room modes, structural vibrations, and fittings may serve to increase the effective absorption at frequencies below 630 Hz. Because of the small dimensions of the enclosure, low-frequency response of the room affected the reliability of the data below 160Hz. Structural vibration of the enclosure was investigated, and may considerably influence the noise breakout from the enclosure apart from the interior acoustical considerations. 4

  3. Acoustic absorption of natural gas compression facility enclosures

    International Nuclear Information System (INIS)

    Lassen, P.; Wong, G.

    2009-01-01

    Noise sources at gas compressor facilities include the enclosure/building housing a gas engine and compressor, the ventilation openings, doors and windows for the enclosure, the engine air intake and exhaust, and a cooler. Accurate predictions of the noise levels inside the enclosure, the breakout noise from open windows and doors and ventilation, as well as the transmission through the walls, is necessary in order to determine cost effective noise mitigation for the facility. In order to accurately predict the sound breakout from these facilities it is necessary to know the acoustic absorption of the interior of these equipment enclosures. Although the acoustic absorption data of the wall systems may be available, the absorption attributable to the non-enclosure surfaces, the equipment and fittings, is not usually known and is difficult to predict. Since piping, instrumentation and mechanical equipment often take on a typical arrangement, shape, volumetric density and material composition, it is useful to know the typical acoustic absorption attributable to these items. In this study, reverberation time (RT) measurements were taken at 2 decommissioned gas compressor facilities in order to determine the absorption characteristics of the enclosure. The RT was measured according to ASTM C423-02a. The overall absorption coefficient of a compressor enclosure with a solid liner was found to be similar to that of steel decking. Fittings within the enclosure did not increase the high frequency absorption of the enclosure. It was concluded that room modes, structural vibrations, and fittings may serve to increase the effective absorption at frequencies below 630 Hz. Because of the small dimensions of the enclosure, low-frequency response of the room affected the reliability of the data below 160Hz. Structural vibration of the enclosure was investigated, and may considerably influence the noise breakout from the enclosure apart from the interior acoustical considerations. 4

  4. Photoelectric absorption cross sections with variable abundances

    Science.gov (United States)

    Balucinska-Church, Monika; Mccammon, Dan

    1992-01-01

    Polynomial fit coefficients have been obtained for the energy dependences of the photoelectric absorption cross sections of 17 astrophysically important elements. These results allow the calculation of X-ray absorption in the energy range 0.03-10 keV in material with noncosmic abundances.

  5. Alkali absorption and citrate excretion in calcium nephrolithiasis

    Science.gov (United States)

    Sakhaee, K.; Williams, R. H.; Oh, M. S.; Padalino, P.; Adams-Huet, B.; Whitson, P.; Pak, C. Y.

    1993-01-01

    The role of net gastrointestinal (GI) alkali absorption in the development of hypocitraturia was investigated. The net GI absorption of alkali was estimated from the difference between simple urinary cations (Ca, Mg, Na, and K) and anions (Cl and P). In 131 normal subjects, the 24 h urinary citrate was positively correlated with the net GI absorption of alkali (r = 0.49, p origin of hypocitraturia. However, the normal dependence was maintained in CDS and in idiopathic hypocitraturia, suggesting that reduced citrate excretion was largely dietary in origin as a result of low net alkali absorption (from a probable relative deficiency of vegetables and fruits or a relative excess of animal proteins).

  6. Absorption technology for solar and waste heat utilization

    International Nuclear Information System (INIS)

    Grossman, G.

    1993-01-01

    Absorption heat pumps, first developed in the 19th century, have received renewed and growing attention in the past two decades. With the increasing cost of oil and electricity, the particular features of this heat-powered cycle have made it attractive for both residential and industrial applications. Solar-powered air conditioning, gas-fired domestic cooling and waste-heat-powered temperature boosters are some of the applications on which intensive research and development has been conducted. This paper describes the operation of absorption systems and discusses several practical applications. It surveys recent advances in absorption technology, including the selection of working fluids, cycle improvements and multi-staging, and fundamentals of the combined heat and mass transfer in absorption processes. (author)

  7. Theory of X-ray absorption and emission spectra

    International Nuclear Information System (INIS)

    Mukoyama, Takeshi

    2004-01-01

    Theoretical studies on X-ray absorption and emission spectroscopy are discussed. Simple expressions for X-ray emission rate and X-ray absorption cross section are presented in the dipole approximation. Various atomic models to obtain realistic wave functions and theoretical calculations for X-ray absorption cross sections and X-ray emission rates are described. In the case of molecules and solids, molecular orbital methods for electronic structures and molecular wave functions are discussed. The emphasis is on the procedures to obtain the excited-state and continuum wave functions for molecules and to calculate the multi-center dipole matrix elements. The examples of the calculated X-ray absorption and emission spectra are shown and compared with the experimental results

  8. Absorption of femtosecond laser pulses by atomic clusters

    International Nuclear Information System (INIS)

    Lin Jingquan; Zhang Jie; Li Yingjun; Chen Liming; Lu Tiezheng; Teng Hao

    2001-01-01

    Energy absorption by Xe, Ar, He atomic clusters are investigated using laser pulses with 5 mJ energy in 150 fs duration. Experimental results show that the size of cluster and laser absorption efficiency are strongly dependent on several factors, such as the working pressure of pulse valve, atomic number Z of the gas. Absorption fraction of Xe clusters is as high as 45% at a laser intensity of 1 x 10 15 W/cm 2 with 20 x 10 5 Pa gas jet backing pressure. Absorption of the atomic clusters is greatly reduced by introducing pre-pulses. Ion energy measurements confirm that the efficient energy deposition results in a plasma with very high ion temperature

  9. Identifying the perfect absorption of metamaterial absorbers

    Science.gov (United States)

    Duan, G.; Schalch, J.; Zhao, X.; Zhang, J.; Averitt, R. D.; Zhang, X.

    2018-01-01

    We present a detailed analysis of the conditions that result in unity absorption in metamaterial absorbers to guide the design and optimization of this important class of functional electromagnetic composites. Multilayer absorbers consisting of a metamaterial layer, dielectric spacer, and ground plane are specifically considered. Using interference theory, the dielectric spacer thickness and resonant frequency for unity absorption can be numerically determined from the functional dependence of the relative phase shift of the total reflection. Further, using transmission line theory in combination with interference theory we obtain analytical expressions for the unity absorption resonance frequency and corresponding spacer layer thickness in terms of the bare resonant frequency of the metamaterial layer and metallic and dielectric losses within the absorber structure. These simple expressions reveal a redshift of the unity absorption frequency with increasing loss that, in turn, necessitates an increase in the thickness of the dielectric spacer. The results of our analysis are experimentally confirmed by performing reflection-based terahertz time-domain spectroscopy on fabricated absorber structures covering a range of dielectric spacer thicknesses with careful control of the loss accomplished through water absorption in a semiporous polyimide dielectric spacer. Our findings can be widely applied to guide the design and optimization of the metamaterial absorbers and sensors.

  10. Heavy nucleus resonance absorption in heterogeneous lattices

    International Nuclear Information System (INIS)

    Coste, M.; Tellier, H.; Brienne-Raepsaet, C.; Van Der Gucht, C.

    1992-01-01

    To compute easily the neutron reaction rates in the resonance energy range, the reactor physicists use the self-shielding formalism and the effective cross-section concept. Usually, for these calculations, and equivalence process is used, in such a way that the absorption rate is correctly computed for the whole fuel pin. This procedure does not allow to preserve the spatial absorption rate distribution inside the pin. It is an important handicap if we want to reproduce the plutonium distribution in a spent fuel. To avoid this inconvenience, new improvements of the self-shielding formalism have been recently introduced in the new assembly calculation code of the French Atomic Energy Commission, APOLLO 2. With this improved formalism, it is now possible to represent the spatial and energetic dependence of the heavy nucleus absorption inside the fuel pin and to use a fine energy dependent equivalence process. As it does not exist clean experimental results for the spatial and energetic dependence of the absorption, the authors used reference calculations to qualify the self-shielding formalism. For the strongly self-shielded nuclei of interest in reactor physics, U238, Pu240 and Th232, the agreement between the self-shielding calculation and the reference ones is fairly good for the spatial and energetic dependence of the absorption rate

  11. Absorption dynamics and delay time in complex potentials

    Science.gov (United States)

    Villavicencio, Jorge; Romo, Roberto; Hernández-Maldonado, Alberto

    2018-05-01

    The dynamics of absorption is analyzed by using an exactly solvable model that deals with an analytical solution to Schrödinger’s equation for cutoff initial plane waves incident on a complex absorbing potential. A dynamical absorption coefficient which allows us to explore the dynamical loss of particles from the transient to the stationary regime is derived. We find that the absorption process is characterized by the emission of a series of damped periodic pulses in time domain, associated with damped Rabi-type oscillations with a characteristic frequency, ω = (E + ε)/ℏ, where E is the energy of the incident waves and ‑ε is energy of the quasidiscrete state of the system induced by the absorptive part of the Hamiltonian; the width γ of this resonance governs the amplitude of the pulses. The resemblance of the time-dependent absorption coefficient with a real decay process is discussed, in particular the transition from exponential to nonexponential regimes, a well-known feature of quantum decay. We have also analyzed the effect of the absorptive part of the potential on the dynamical delay time, which behaves differently from the one observed in attractive real delta potentials, exhibiting two regimes: time advance and time delay.

  12. On the nature of absorption features toward nearby stars

    Science.gov (United States)

    Kohl, S.; Czesla, S.; Schmitt, J. H. M. M.

    2016-06-01

    Context. Diffuse interstellar absorption bands (DIBs) of largely unknown chemical origin are regularly observed primarily in distant early-type stars. More recently, detections in nearby late-type stars have also been claimed. These stars' spectra are dominated by stellar absorption lines. Specifically, strong interstellar atomic and DIB absorption has been reported in τ Boo. Aims: We test these claims by studying the strength of interstellar absorption in high-resolution TIGRE spectra of the nearby stars τ Boo, HD 33608, and α CrB. Methods: We focus our analysis on a strong DIB located at 5780.61 Å and on the absorption of interstellar Na. First, we carry out a differential analysis by comparing the spectra of the highly similar F-stars, τ Boo and HD 33608, whose light, however, samples different lines of sight. To obtain absolute values for the DIB absorption, we compare the observed spectra of τ Boo, HD 33608, and α CrB to PHOENIX models and carry out basic spectral modeling based on Voigt line profiles. Results: The intercomparison between τ Boo and HD 33608 reveals that the difference in the line depth is 6.85 ± 1.48 mÅ at the DIB location which is, however, unlikely to be caused by DIB absorption. The comparison between PHOENIX models and observed spectra yields an upper limit of 34.0 ± 0.3 mÅ for any additional interstellar absorption in τ Boo; similar results are obtained for HD 33608 and α CrB. For all objects we derive unrealistically large values for the radial velocity of any presumed interstellar clouds. In τ Boo we find Na D absorption with an equivalent width of 0.65 ± 0.07 mÅ and 2.3 ± 0.1 mÅ in the D2 and D1 lines. For the other Na, absorption of the same magnitude could only be detected in the D2 line. Our comparisons between model and data show that the interstellar absorption toward τ Boo is not abnormally high. Conclusions: We find no significant DIB absorption in any of our target stars. Any differences between modeled and

  13. Absorption/desorption in sprays

    International Nuclear Information System (INIS)

    Naimpally, A.

    1987-01-01

    This survey paper shall seek to present the present state of knowledge concerning absorption and desorption in spray chambers. The first part of the paper presents the theories and formulas for the atomization and break-up of sprays in nozzles. Formulas for the average (sauter-mean) diameters are then presented. For the case of absorption processes, the formulas for the dimensionless mass transfer coefficients is in drops. The total; mass transfer is the total of the transfer in individual drops. For the case of desorption of sparingly soluble gases from liquids in a spray chamber, the mass transfer occurs in the spray just at the point of break-up of the jet. Formulas for the desorption of gases are presented

  14. Experimental methodology for obtaining sound absorption coefficients

    Directory of Open Access Journals (Sweden)

    Carlos A. Macía M

    2011-07-01

    Full Text Available Objective: the authors propose a new methodology for estimating sound absorption coefficients using genetic algorithms. Methodology: sound waves are generated and conducted along a rectangular silencer. The waves are then attenuated by the absorbing material covering the silencer’s walls. The attenuated sound pressure level is used in a genetic algorithm-based search to find the parameters of the proposed attenuation expressions that include geometric factors, the wavelength and the absorption coefficient. Results: a variety of adjusted mathematical models were found that make it possible to estimate the absorption coefficients based on the characteristics of a rectangular silencer used for measuring the attenuation of the noise that passes through it. Conclusions: this methodology makes it possible to obtain the absorption coefficients of new materials in a cheap and simple manner. Although these coefficients might be slightly different from those obtained through other methodologies, they provide solutions within the engineering accuracy ranges that are used for designing noise control systems.

  15. Is oral absorption of vigabatrin carrier-mediated?

    DEFF Research Database (Denmark)

    Nøhr, M. K.; Juul, R. V.; Thale, Z. I.

    2015-01-01

    by mechanistic non-linear mixed effects modelling, evaluating PAT1-ligands as covariates on the PK parameters with a full covariate modelling approach. The oral absorption of vigabatrin was adequately described by a Michaelis-Menten type saturable absorption. Using a Michaelis constant of 32.8 mM, the model......-mediated and if the proton-coupled amino acid transporter 1 (PAT1) was involved in the absorption processes. Vigabatrin (0.3-300 mg/kg) was administered orally or intravenously to Sprague Dawley rats in the absence or presence of PAT1-ligands l-proline, l-tryptophan or sarcosine. The PK profiles of vigabatrin were described...... estimated a maximal oral absorption rate (Vmax) of 64.6 mmol/min and dose-dependent bioavailability with a maximum of 60.9%. Bioavailability was 58.5-60.8% at 0.3-30 mg/kg doses, but decreased to 46.8% at 300 mg/kg. Changes in oral vigabatrin PK after co-administration with PAT1-ligands was explained...

  16. Radiant absorption characteristics of corrugated curved tubes

    Directory of Open Access Journals (Sweden)

    Đorđević Milan Lj.

    2017-01-01

    Full Text Available The utilization of modern paraboloidal concentrators for conversion of solar radiation into heat energy requires the development and implementation of compact and efficient heat absorbers. Accurate estimation of geometry influence on absorption characteristics of receiver tubes is an important step in this process. This paper deals with absorption characteristics of heat absorber made of spirally coiled tubes with transverse circular corrugations. Detailed 3-D surface-to-surface Hemicube method was applied to compare radiation performances of corrugated and smooth curved tubes. The numerical results were obtained by varying the tube curvature ratio and incident radiant heat flux intensity. The details of absorption efficiency of corrugated tubes and the effect of curvature on absorption properties for both corrugated and smooth tubes were presented. The results may have significance to further analysis of highly efficient heat absorbers exposed to concentrated radiant heating. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 42006

  17. Theory of strong-field attosecond transient absorption

    International Nuclear Information System (INIS)

    Wu, Mengxi; Chen, Shaohao; Camp, Seth; Schafer, Kenneth J; Gaarde, Mette B

    2016-01-01

    Attosecond transient absorption is one of the promising new techniques being developed to exploit the availability of sub-femtosecond extreme ultraviolet (XUV) pulses to study the dynamics of the electron on its natural time scale. The temporal resolution in a transient absorption setup comes from the control of the relative delay and coherence between pump and probe pulses, while the spectral resolution comes from the characteristic width of the features that are being probed. In this review we focus on transient absorption scenarios where an attosecond pulse of XUV radiation creates a broadband excitation that is subsequently probed by a few cycle infrared (IR) laser. Because the attosecond XUV pulses are locked to the IR field cycle, the exchange of energy in the laser–matter interaction can be studied with unprecedented precision. We focus on the transient absorption by helium atoms of XUV radiation around the first ionization threshold, where we can simultaneoulsy solve the time-dependent Schrödinger equation for the single atom response and the Maxwell wave equation for the collective response of the nonlinear medium. We use a time-domain method that allows us to treat on an equal footing all the different linear and nonlinear processes by which the medium can exchange energy with the fields. We present several simple models, based on a few-level system interacting with a strong IR field, to explain many of the novel features found in attosecond transient absorption spectrograms. These include the presence of light-induced states, which demonstrate the ability to probe the dressed states of the atom. We also present a time-domain interpretation of the resonant pulse propagation features that appear in absorption spectra in dense, macroscopic media. We close by reviewing several recent experimental results that can be explained in terms of the models we discuss. Our aim is to present a road map for understanding future attosecond transient absorption

  18. A new in vitro lipid digestion - in vivo absorption model to evaluate the mechanisms of drug absorption from lipid-based formulations.

    Science.gov (United States)

    Crum, Matthew F; Trevaskis, Natalie L; Williams, Hywel D; Pouton, Colin W; Porter, Christopher J H

    2016-04-01

    In vitro lipid digestion models are commonly used to screen lipid-based formulations (LBF), but in vitro-in vivo correlations are in some cases unsuccessful. Here we enhance the scope of the lipid digestion test by incorporating an absorption 'sink' into the experimental model. An in vitro model of lipid digestion was coupled directly to a single pass in situ intestinal perfusion experiment in an anaesthetised rat. The model allowed simultaneous real-time analysis of the digestion and absorption of LBFs of fenofibrate and was employed to evaluate the influence of formulation digestion, supersaturation and precipitation on drug absorption. Formulations containing higher quantities of co-solvent and surfactant resulted in higher supersaturation and more rapid drug precipitation in vitro when compared to those containing higher quantities of lipid. In contrast, when the same formulations were examined using the coupled in vitro lipid digestion - in vivo absorption model, drug flux into the mesenteric vein was similar regardless of in vitro formulation performance. For some drugs, simple in vitro lipid digestion models may underestimate the potential for absorption from LBFs. Consistent with recent in vivo studies, drug absorption for rapidly absorbed drugs such as fenofibrate may occur even when drug precipitation is apparent during in vitro digestion.

  19. Determination of the separation between the soft X-ray K-emission and K-absorption edges in beryllium metal from self-absorption studies

    International Nuclear Information System (INIS)

    Crisp, R.S.

    1979-01-01

    Recent theoretical studies have aroused interest in the phonon broadening of the soft X-ray emission and absorption edges and the shift between them. Using a self-absorption technique a separation of about 0.2 eV is shown to exist between the edges in Be metal. This shift explains the very small self-absorption effects previously observed in Be. (Auth.)

  20. Absorptive form factors for high-energy electron diffraction

    International Nuclear Information System (INIS)

    Bird, D.M.; King, Q.A.

    1990-01-01

    The thermal diffuse scattering contribution to the absorptive potential in high-energy electron diffraction is calculated in the form of an absorptive contribution to the atomic form factor. To do this, the Einstein model of lattice vibrations is used, with isotropic Debye-Waller factors. The absorptive form factors are calculated as a function of scattering vector s and temperature factor M on a grid which enables polynomial interpolation of the results to be accurate to better than 2% for much of the ranges 0≤Ms 2 ≤6 and 0≤M≤2 A 2 . The computed values, together with an interpolation routine, have been incorporated into a Fortran subroutine which calculates both the real and absorptive form factors for 54 atomic species. (orig.)

  1. Luminescence and optical absorption determination in porous silicon

    International Nuclear Information System (INIS)

    Nogal, U.; Calderon, A.; Marin, E.; Rojas T, J. B.; Juarez, A. G.

    2012-10-01

    We applied the photoacoustic spectroscopy technique in order to obtain the optical absorption spectrum in porous silicon samples prepared by electrochemical anodic etching on n-type, phosphorous doped, (100)-oriented crystal-line silicon wafer with thickness of 300 μm and 1-5 ωcm resistivity. The porous layers were prepared with etching times of 13, 20, 30, 40 and 60 minutes. Also, we realized a comparison among the optical absorption spectrum with the photoluminescence and photo reflectance ones, both obtained at room temperature. Our results show that the absorption spectrum of the samples of porous silicon depends notably of the etching time an it consist of two distinguishable absorption bands, one in the Vis region and the other one in the UV region. (Author)

  2. Comparison and Analysis of Lithium Bromide-water Absorption Chillers Using Plastic Heat Transfer Tubes and Traditional Lithium Bromide-water Absorption Chillers

    OpenAIRE

    Xue-dong Zhang

    2010-01-01

    There are extensive applications of lithium bromide-water absorption chillers in industry, but the heat exchangers corrosion and refrigerating capacity loss are very difficult to be solved. In this paper, an experiment was conducted by using plastic heat transfer tubes instead of copper tubes. As an example, for a lithium bromide-water absorption chiller of refrigerating capacity of 35kW, the correlative performance of the lithium bromide-water absorption chiller using pl...

  3. Absorption of orally administered 65Zn by normal human subjects

    International Nuclear Information System (INIS)

    Aamodt, R.L.; Rumble, W.F.; Johnston, G.S.; Markley, E.J.; Henkin, R.I.

    1981-01-01

    Despite studies by several investigators of human gastrointestinal 65Zn absorption, implications of these data for evaluation of functional zinc status are unclear because limited numbers of normal subjects have been studied. To evaluated zinc absorption in normal humans, 75 subjects (31 women, 44 men, ages 18 to 84 yr) were given 10 micro Ci carrier-free 65Zn orally after an overnight fast. Absorption calculated from total body retention measured 7, 14, and 21 days after administration of tracer was 65 +/- 11% (mean +/- 1 SD), range from 40 to 86%. Comparison of these results with those for patients with a variety of diseases indicate that patients exhibit a wider range of absorption and, in four of six studies patients exhibit decreased mean zinc absorption. These results of gastrointestinal zinc absorption in a large number of normal humans offer a basis for a clearer comparison with data from patients who exhibit abnormalities of zinc absorption

  4. Intestinal absorption of copper: influence of carbohydrates.

    Science.gov (United States)

    Wapnir, R A; Balkman, C

    1992-02-01

    Macronutrients can modulate the intestinal absorption of trace elements by binding the metal or altering mucosal function. We investigated whether certain simple and complex carbohydrates modify copper (Cu) absorption, using an in vivo perfusion technique in the rat. Corn syrup solids, which contain a mixture of glucose polymers of diverse length, added at either 20 or 50 mosm/kg enhanced Cu absorption from a 31.5 microM (2 mg/liter) Cu solution (128 +/- 11 and 130 +/- 11 pmol/min x cm, respectively, vs 101 +/- 4 pmol/min x cm, P less than 0.05, in the absence of carbohydrate). This was concomitant with a stimulation of net water absorption (1.05 +/- 0.08 and 0.84 +/- 0.08 microliter/min x cm, respectively, vs 0.63 +/- 0.02 microliter/min x cm with no carbohydrate, P less than 0.05). Glucose, fructose, lactose, or sucrose had no influence on Cu absorption, although they altered water exchanges, an effect attributable to a reduction of the outflow component of fluid recirculation. Low concentrations of lactose resulted in a greater accumulation of Cu in the intestinal mucosa (8.75 +/- 0.71 micrograms/g vs 5.77 +/- 0.68 micrograms/g for controls, P less than 0.05). Hence, solutes that moderately stimulate mucosa-to-serosa fluid influx in a progressive manner, such as glucose polymers, may contribute to functionally increase Cu absorption. Conversely, conditions which tend to reduce water inflow or increase water outflow across the small intestinal mucosa, as may occur with high lactose diets or in cases of chronic diarrhea, may have negative effects.

  5. Variations in the spectral values of specific absorption of phytoplankton

    Digital Repository Service at National Institute of Oceanography (India)

    Sathyendranath, S.; Lazzara, L.; Prieur, L.

    Absorption spectra of laboratory cultures of eight species of phytoplankton were studied. These spectra, normalized per unit of chlorophyll a concentration (specific absorption) show variability in magnitude and spectral form. Specific absorption...

  6. Controlling enhanced absorption in graphene metamaterial

    Science.gov (United States)

    Zhou, Qihui; Liu, Peiguo; Bian, Li-an; Liu, Hanqing; Liu, Chenxi; Chen, Genghui

    2018-04-01

    In this paper, a controllable terahertz (THz) metamaterial absorber (MA) is designed with the circuit analog method. Taking advantage of the patterned graphene on SiO2/doped Si/polyimide substrates with a gold reflector, the controllable MA achieves perfect absorption at 0.75 THz. The chemical potential of graphene is regulated by controlling the voltage between graphene and doped Si layers. As the chemical potential varies from 0 eV to 0.5 eV, the MA is changed from reflection (0.99). The distributions of surface current and electric field are illustrated to analyze the resonant characteristic of patterned graphene. According to the resonant characteristic, we introduce patterned graphene elements with different dimension in a unit cell, which effectively extends the effective absorption bandwidth (absorption > 0 . 9) from 0.67-0.93 THz to 0.52-0.95 THz. Moreover, replacing part of the graphene structure with gold, the switchable MA is turned into a frequency tunable MA. The absorption peak moves from 0.62 THz to 0.92 THz as the chemical potential increases from 0.1 eV to 0.5 eV. These designs overcome limitation of traditional absorbers and exhibit great potentials in many practical applications.

  7. Realistic absorption coefficient of ultrathin films

    International Nuclear Information System (INIS)

    Cesaria, M; Caricato, A P; Martino, M

    2012-01-01

    Both a theoretical algorithm and an experimental procedure are discussed of a new route to determine the absorption/scattering properties of thin films deposited on transparent substrates. Notably, the non-measurable contribution of the film–substrate interface is inherently accounted for. While the experimental procedure exploits only measurable spectra combined according to a very simple algorithm, the theoretical derivation does not require numerical handling of the acquired spectra or any assumption on the film homogeneity and substrate thickness. The film absorption response is estimated by subtracting the measured absorption spectrum of the bare substrate from that of the film on the substrate structure but in a non-straightforward way. In fact, an assumption about the absorption profile of the overall structure is introduced and a corrective factor accounting for the relative film-to-substrate thickness. The method is tested on films of a well known material (ITO) as a function of the film structural quality and influence of the film–substrate interface, both deliberately changed by thickness tuning and doping. Results are found fully consistent with information obtained by standard optical analysis and band gap values reported in the literature. Additionally, comparison with a conventional method demonstrates that our route is generally more accurate even if particularly suited for very thin films. (paper)

  8. Realistic absorption coefficient of ultrathin films

    Science.gov (United States)

    Cesaria, M.; Caricato, A. P.; Martino, M.

    2012-10-01

    Both a theoretical algorithm and an experimental procedure are discussed of a new route to determine the absorption/scattering properties of thin films deposited on transparent substrates. Notably, the non-measurable contribution of the film-substrate interface is inherently accounted for. While the experimental procedure exploits only measurable spectra combined according to a very simple algorithm, the theoretical derivation does not require numerical handling of the acquired spectra or any assumption on the film homogeneity and substrate thickness. The film absorption response is estimated by subtracting the measured absorption spectrum of the bare substrate from that of the film on the substrate structure but in a non-straightforward way. In fact, an assumption about the absorption profile of the overall structure is introduced and a corrective factor accounting for the relative film-to-substrate thickness. The method is tested on films of a well known material (ITO) as a function of the film structural quality and influence of the film-substrate interface, both deliberately changed by thickness tuning and doping. Results are found fully consistent with information obtained by standard optical analysis and band gap values reported in the literature. Additionally, comparison with a conventional method demonstrates that our route is generally more accurate even if particularly suited for very thin films.

  9. Absorption from iron tablets given with different types of meals

    International Nuclear Information System (INIS)

    Hallberg, L.; Bjoern-Rasmussen, E.; Ekenved, G.; Garby, L.; Rossander, L.; Pleehachinda, R.; Suwanik, R.; Arvidsson, B.

    1978-01-01

    The absorption from iron tablets given with 5 types of meals was studied in 153 subjects. The meals were: a hamburger meal with beans and potatoes, a simple breakfast meal, a Latin American meal composed of black beans, rice and maize and two Southeast Asian meals composed of rice, vegetables, and spices served with and without fish. The groups were directly compared by relating the absorption from the iron tablets to the absorption from a standardized reference dose of iron given on an empty stomach. The composition of meals with respect to content of meat or fish or the presence of large amounts of phytates seemed to have no influence on the absorption of iron from tablets. The absorption from iron tablets was about 40% higher when they were given with rice meals than when they were given with the other meals studied. The average decrease in absorption by meals was about 50-60% based on a comparison when tablets were given on an empty stomach. When tablets from which the iron was released more slowly were used, the absorption increased by about 30% except when they were given with rice meals, where the absorption was unchanged. The differences among the meals in their effect on the absorption of iron from tablets thus disappeared when the slow-release tablets were given. (author)

  10. Absorption from iron tablets given with different types of meals

    Energy Technology Data Exchange (ETDEWEB)

    Hallberg, L; Bjoern-Rasmussen, E; Ekenved, G; Garby, L; Rossander, L; Pleehachinda, R; Suwanik, R; Arvidsson, B

    1978-01-01

    The absorption from iron tablets given with 5 types of meals was studied in 153 subjects. The meals were: a hamburger meal with beans and potatoes, a simple breakfast meal, a Latin American meal composed of black beans, rice and maize and two Southeast Asian meals composed of rice, vegetables, and spices served with and without fish. The groups were directly compared by relating the absorption from the iron tablets to the absorption from a standardized reference dose of iron given on an empty stomach. The composition of meals with respect to content of meat or fish or the presence of large amounts of phytates seemed to have no influence on the absorption of iron from tablets. The absorption from iron tablets was about 40% higher when they were given with rice meals than when they were given with the other meals studied. The average decrease in absorption by meals was about 50-60% based on a comparison when tablets were given on an empty stomach. When tablets from which the iron was released more slowly were used, the absorption increased by about 30% except when they were given with rice meals, where the absorption was unchanged. The differences among the meals in their effect on the absorption of iron from tablets thus disappeared when the slow-release tablets were given.

  11. Absorption from iron tablets given with different types of meals.

    Science.gov (United States)

    Hallberg, L; Björn-Rasmussen, E; Ekenved, G; Garby, L; Rossander, L; Pleehachinda, R; Suwanik, R; Arvidsson, B

    1978-09-01

    The absorption of iron from tablets given with 5 types of meals was studied in 153 subjects. The meals were: a hamburger meal with beans and potatoes, a simple breakfast meal, a Latin American meal composed of black beans, rice and maize and two Southeast Asian meals composed of rice, vegetables and spices served with and without fish. The groups were directly compared by relating the absorption from the iron tablets to the absorption from a standardized reference dose of iron given on an empty stomach. The composition of meals with respect to content of meat or fish or the presence of large amounts of phytates seemed to have no influence on the absorption of iron from tablets. The absorption from iron tablets was about 40% higher when they were given with rice meals than when they were given with the other meals studied. The average decrease in absorption by meals was about 50-60% based on a comparison when tablets were given on an empty stomach. When tablets from which the iron was released more slowly were used, the absorption increased by about 30% except when they were given with rice meals, where the absorption was unchanged. The differences among the meals in their effect on the absorption of iron from tablets thus disappeared when the slow-release tablets were given.

  12. Gold analysis by the gamma absorption technique

    International Nuclear Information System (INIS)

    Kurtoglu, Arzu; Tugrul, A.B.

    2003-01-01

    Gold (Au) analyses are generally performed using destructive techniques. In this study, the Gamma Absorption Technique has been employed for gold analysis. A series of different gold alloys of known gold content were analysed and a calibration curve was obtained. This curve was then used for the analysis of unknown samples. Gold analyses can be made non-destructively, easily and quickly by the gamma absorption technique. The mass attenuation coefficients of the alloys were measured around the K-shell absorption edge of Au. Theoretical mass attenuation coefficient values were obtained using the WinXCom program and comparison of the experimental results with the theoretical values showed generally good and acceptable agreement

  13. Comparison of water absorption methods: testing the water absorption of recently quarried and weathered porous limestone on site and under laboratory conditions

    Science.gov (United States)

    Rozgonyi-Boissinot, Nikoletta; Agárdi, Tamás; Karolina Cebula, Ágnes; Török, Ákos

    2017-04-01

    The water absorption of weathering sensitive stones is a critical parameter that influences durability. The current paper compares different methods of water absorption tests by using on site and laboratory tests. The aims of the tests were to assess the water absorption of un-weathered quarry stones and various weathering forms occurring on porous limestone monuments. For the tests a Miocene porous limestone was used that occurs in Central and Western Hungary and especially near and in Budapest. Besides the Hungarian occurrences the same or very similar porous limestones are found in Austria, Slovakia and in the Czech Republic. Several quarries were operating in these countries. Due to the high workability the stone have been intensively used as construction material from the Roman period onward. The most prominent monuments made of this stone were built in Vienna and in Budapest during the 18th -19th century and in the early 20th century. The high porosity and the micro-fabric of the stone make it prone to frost- and salt weathering. Three different limestone types were tested representing coarse-, medium- and fine grained lithologies. The test methods included Rilem tube (Karsten tube) tests and capillary water absorption tests. The latter methodology has been described in detail in EN 1925:2000. The test results of on-site tests of weathered porous limestone clearly show that the water absorption of dissolved limestone surfaces and crumbling or micro-cracked limestone is similar. The water absorption curves have similar inclinations marking high amount of absorbed water. To the contrary, the white weathering crusts covered stone blocks and black crusts have significantly lower water absorptions and many of these crusts are considered as very tight almost impermeable surfaces. Capillary water absorption tests in the laboratory allowed the determination of maximum water absorption of quarried porous limestone. Specimens were placed in 3 mm of water column and the

  14. Time-resolved absorption measurements on OMEGA

    International Nuclear Information System (INIS)

    Jaanimagi, P.A.; DaSilva, L.; Delettrez, J.; Gregory, G.G.; Richardson, M.C.

    1986-01-01

    Time-resolved measurements of the incident laser light that is scattered and/or refracted from targets irradiated by the 24 uv-beam OMEGA laser at LLE, have provided some interesting features related to time-resolved absorption. The decrease in laser absorption characteristic of irradiating a target that implodes during the laser pulse has been observed. The increase in absorption expected as the critical density surface moves from a low to a high Z material in the target has also been noted. The detailed interpretation of these results is made through comparisons with simulation using the code LILAC, as well as with streak data from time-resolved x-ray imaging and spectroscopy. In addition, time and space-resolved imaging of the scattered light yields information on laser irradiation uniformity conditions on the target. The report consists of viewgraphs

  15. Selective gas absorption by ionic liquids

    DEFF Research Database (Denmark)

    Shunmugavel, Saravanamurugan; Kegnæs, Søren; Due-Hansen, Johannes

    2010-01-01

    Reversible absorption performance for the flue gas components CO 2, NO and SO2 has been tested for several different ionic liquids (ILs) at different temperatures and flue gas compositions. Furthermore, different porous, high surface area carriers have been applied as supports for the ionic liquids...... to obtain Supported Ionic Liquid-Phase (SILP) absorber materials. The use of solid SILP absorbers with selected ILs were found to significantly improve the absorption capacity and sorption dynamics at low flue gas concentration, thus making the applicability of ILs viable in technical, continuous flow...... processes for flue gas cleaning. The results show that CO 2, NO and SO2 can be reversible and selective absorbed using different ILs and that Supported Ionic Liquid-Phase (SILP) absorbers are promising materials for industrial flue gas cleaning. Absorption/desorption dynamics can be tuned by temperatures...

  16. Lithium absorption by the rabbit gall-bladder

    DEFF Research Database (Denmark)

    Hansen, C P; Holstein-Rathlou, N H; Skøtt, O

    1991-01-01

    Lithium (Li+) absorption across the low-resistance epithelium of the rabbit gall-bladder was studied in order to elucidate possible routes and mechanisms of Li+ transfer. Li+ at a concentration of 0.4 mM in both mucosal and serosal media did not affect isosmotic mucosa-to-serosa fluid absorption...

  17. Absorption of plutonium in the iron-deficient rat

    International Nuclear Information System (INIS)

    Ragan, H.A.

    1977-01-01

    Iron deficiency did not enhance absorption of plutonium following intragastric gavage of rats. Absorption of plutonium citrate in both control and iron-deficient rats was about 0.03% of the administered dose

  18. Vehicle effects on human stratum corneum absorption and skin penetration.

    Science.gov (United States)

    Zhang, Alissa; Jung, Eui-Chang; Zhu, Hanjiang; Zou, Ying; Hui, Xiaoying; Maibach, Howard

    2017-05-01

    This study evaluated the effects of three vehicles-ethanol (EtOH), isopropyl alcohol (IPA), and isopropyl myristate (IPM)-on stratum corneum (SC) absorption and diffusion of the [ 14 C]-model compounds benzoic acid and butenafine hydrochloride to better understand the transport pathways of chemicals passing through and resident in SC. Following application of topical formulations to human dermatomed skin for 30 min, penetration flux was observed for 24 h post dosing, using an in vitro flow-through skin diffusion system. Skin absorption and penetration was compared to the chemical-SC (intact, delipidized, or SC lipid film) binding levels. A significant vehicle effect was observed for chemical skin penetration and SC absorption. IPA resulted in the greatest levels of intact SC/SC lipid absorption, skin penetration, and total skin absorption/penetration of benzoic acid, followed by IPM and EtOH, respectively. For intact SC absorption and total skin absorption/penetration of butenafine, the vehicle that demonstrated the highest level of sorption/penetration was EtOH, followed by IPA and IPM, respectively. The percent doses of butenafine that were absorbed in SC lipid film and penetrated through skin in 24 h were greatest for IPA, followed by EtOH and IPM, respectively. The vehicle effect was consistent between intact SC absorption and total chemical skin absorption and penetration, as well as SC lipid absorption and chemical penetration through skin, suggesting intercellular transport as a main pathway of skin penetration for model chemicals. These results suggest the potential to predict vehicle effects on skin permeability with simple SC absorption assays. As decontamination was applied 30 min after chemical exposure, significant vehicle effects on chemical SC partitioning and percutaneous penetration also suggest that skin decontamination efficiency is vehicle dependent, and an effective decontamination method should act on chemical solutes in the lipid domain.

  19. Absorption Efficiency of Receiving Antennas

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Frandsen, Aksel

    2005-01-01

    A receiving antenna with a matched load will always scatter some power. This paper sets an upper and a lower bound on the absorption efficiency (absorbed power over sum of absorbed and scattered powers), which lies between 0 and 100% depending on the directivities of the antenna and scatter...... patterns. It can approach 100% as closely as desired, although in practice this may not be an attractive solution. An example with a small endfire array of dipoles shows an efficiency of 93%. Several examples of small conical horn antennas are also given, and they all have absorption efficiencies less than...

  20. Calcium absorption response to cholecalciferol supplementation in hemodialysis.

    Science.gov (United States)

    Armas, Laura A G; Zena, Mohsen; Lund, Richard; Heaney, Robert P

    2013-06-01

    Recent understanding of extrarenal production of calcitriol has led to the use of more vitamin D supplementation in CKD populations. This paper reports the effect of cholecalciferol supplementation on calcium absorption. Paired calcium absorption tests were done before and after 12-13 weeks of 20,000 IU weekly cholecalciferol supplementation in 30 participants with stage 5 CKD on hemodialysis. The study was conducted from April to December of 2011. Calcium absorption was tested with a standardized meal containing 300 mg calcium carbonate intrinsically labeled with (45)Ca; 25-hydroxyvitamin D and 1,25-dihydroxyvitamin D were measured. 25-Hydroxyvitamin D rose from 14.2 ng/ml (11.5-18.5) at baseline to 49.3 ng/ml (42.3-58.1) at the end of the study (P<0.001). 1,25-Dihydroxyvitamin D rose from 15.1 (10.5-18.8) pg/ml at baseline to 20.5 (17.0-24.7) pg/ml at the end of the study (P<0.001). The median baseline calcium absorption was 12% (7%-17%) and 12% (7%-16%) at the end of study. Patients with stage 5 CKD on hemodialysis had very low calcium absorption values at baseline, and cholecalciferol supplementation that raised 25(OH)D levels to 50 ng/ml had no effect on calcium absorption.

  1. Dynamics of water absorption through superabsorbent polymer

    Science.gov (United States)

    Chang, Sooyoung; Kim, Wonjung

    2017-11-01

    Superabsorbent polymers (SAPs) consist of hydrophilic cross-linked polymer networks that can absorb and retain a great amount of water relative to their own mass, so that they are widely used for disposable diapers and holding soil moisture in agriculture. SAPs are typically available in the form of submillimeter-sized particles, and the water absorption is driven by capillary flows between particles as well as diffusion that entail swelling. Although the control of water absorption of SAPs is important in engineering applications, but the dynamics of water absorption in SAP particles has not been fully understood. We examine the dynamics of the water absorption of sodium polyacrylate, one of the most common SAP. We experimentally measured the water absorption of sodium polyacrylate particles in one-dimensional confined channel. The water flows through the particles were analyzed by capillarity dominant at the early stage and by diffusion involving volume expansion critical at a later stage. The results provide a quantitative basis of the hydrodynamic analysis of the water flow through SAP particles from a macroscopic point of view, facilitating the prediction of water uptake of SAPs in hygienic and agricultural applications. This work was supported by the National Research Foundation of Korea (NRF) Grant funded by the Korea government (MSIP) (No.2015R1A2A2A04006181).

  2. Optical absorption in recycled waste plastic polyethylene

    Science.gov (United States)

    Aji, M. P.; Rahmawati, I.; Priyanto, A.; Karunawan, J.; Wati, A. L.; Aryani, N. P.; Susanto; Wibowo, E.; Sulhadi

    2018-03-01

    We investigated the optical properties of UV spectrum absorption in recycled waste plastic from polyethylene polymer type. Waste plastic polyethylene showed an optical spectrum absorption after it’s recycling process. Spectrum absorption is determined using spectrophotometer UV-Nir Ocean Optics type USB 4000. Recycling method has been processed using heating treatment around the melting point temperature of the polyethylene polymer that are 200°C, 220°C, 240°C, 260°C, and 280°C. In addition, the recycling process was carried out with time variations as well, which are 1h, 1.5h, 2h, and 2.5h. The result of this experiment shows that recycled waste plastic polyethylene has a spectrum absorption in the ∼ 340-550 nm wavelength range. The absorbance spectrum obtained from UV light which is absorbed in the orbital n → π* and the orbital π → π*. This process indicates the existence of electron transition phenomena. This mechanism is affected by the temperature and the heating time where the intensity of absorption increases and widens with the increase of temperature and heating time. Furthermore this study resulted that the higher temperature affected the enhancement of the band gap energy of waste plastic polyethylene. These results show that recycled waste plastic polyethylene has a huge potential to be absorber materials for solar cell.

  3. Determination of the separation between the soft X-ray K-emission and K-absorption edges in beryllium metal from self-absorption studies

    International Nuclear Information System (INIS)

    Crisp, R.S.

    1979-01-01

    Recent theoretical studies have aroused interest in the phonon broadening of the soft X-ray emission and absorption edges and the shift between them. Using a self-absorption technique a separation of about 0.2 eV is shown to exist between the edges in Be metal. This shift explains the very small self-absorption effects previously observed in Be by Crisp (1977). (Auth.)

  4. Zeeman atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Hadeishi, T.; McLaughlin, R.

    1978-08-01

    The design and development of a Zeeman atomic absorption spectrometer for trace element analysis are described. An instruction manual is included which details the operation, adjustment, and maintenance. Specifications and circuit diagrams are given

  5. The application of atomic absorption spectrometry to chemical analysis

    International Nuclear Information System (INIS)

    Walsh, A.

    1980-01-01

    YhThe history of the development of atomic absorption methods of elemental analysis is outlined. The theoretical basis of atomic absorption methods is discussed and the principle of modern methods of atomic absorption measurements is described. The advantages, scope and limations of these methods are discussed. Related methods based on the measurement of atomic fluorescence are also described

  6. Molecular absorption spectra of beryllium, cerium, lanthanum, iron, and platinum salts

    International Nuclear Information System (INIS)

    Daidoji, Hidehiro

    1980-01-01

    The absorption spectra of some salts of beryllium, cerium, lanthanum, iron and platinum in air-acetylene flame were measured in the wavelength range from 200 to 400 nm. A Hitachi 207 type atomic absorption spectrophotometer was used. A deuterium lamp, a home-made continuous radiation lamp and some hollow cathode lamps were used as light sources. The new molecular absorption spectra of cerium, lanthanum and platinum and the absorption spectra due to Be(OH) 2 , LaO, PtH, FeO and FeCl in 200-400 nm region were obtained. Emission spectra of CeO, LaO and FeOH were also obtained. These molecular absorption bands were estimated as absorption errors of maximum 15 times to the sensitivity of each elements in atomic absorption spectrometry. In addition, spectral line interferences of iron were observed in atomic absorption spectrometry of Zn, Cd, Ni, Cu and Cr. (author)

  7. Bent Electro-Absorption Modulator

    DEFF Research Database (Denmark)

    2002-01-01

    by applying a variable electric or electronmagnetic field. The modulation of the complex refractive index results in a modulation of the refractive index contrast and the absorption coefficient for the waveguide at the frequency of the light. By carefully adjusting the composition of the semiconducting...... components and the applied electric field in relation to the frequency of the modulated radiation, the bending losses (and possibly coupling losses) will provide extinction of light guided by the bent waveguide section. The refractive index contract may be modulated while keeping the absorption coefficient......The present invention relates to a method and a device for modulating optical signals based on modulating bending losses in bend, quantum well semiconductor waveguide sections. The complex refractive index of the optical active semiconducting components of the waveguide section is modulated...

  8. Structural slow light can enhance Beer-Lambert absorption

    OpenAIRE

    Dicaire Isabelle; Chin Sanghoon; Thévenaz Luc

    2011-01-01

    We experimentally demonstrate that structural slow light can enhance Beer-Lambert absorption. A 4-fold reduction of the group velocity induced by mere cavity effects has caused an increase of molecular absorption by 130%.

  9. Absorption of l-methionine from the human small intestine

    Science.gov (United States)

    Schedl, Harold P.; Pierce, Charles E.; Rider, Alan; Clifton, James A.

    1968-01-01

    Absorption of L-methionine was measured in all parts of the human small intestine using transintestinal intubation and perfusion. In four normal subjects, adsorption was higher in the proximal than in the distal intestine. In two patients with nontropical sprue in relapse, there was a proximal zone of low absorption with higher absorption distally. In all parts of the small intestine, absorption showed rate-limiting kinetics as methionine concentration was increased. In normal subjects, the proximal Km (Michaelis constant) was more than 3 times higher than the distal, which suggests a difference in transport mechanisms between the two segments. PMID:12066784

  10. Angular absorption of iridium - ICW12 needles: practical considerations

    International Nuclear Information System (INIS)

    Szymczyk, W.; Lesiak, J.

    1984-01-01

    An analysis was made of two potential sources of error in Ir 192 dosimetry: the effect of angular absorption and the differences in the ionization constants found in literature. Corrections for selfabsorption in the ICW12 iridium source were determined from measurements and calculations. It was found that the decrease in the dose caused by the angular absorption in the central therapeutic area of a typical implantation can exceed 5 percent. The need for employing the concept of ''constant exposure rate'' is stressed as well as that for using angular absorption in the form of absorption. 13 refs., 6 figs., 1 tab. (author)

  11. X-ray absorption intensity at high-energy region

    International Nuclear Information System (INIS)

    Fujikawa, Takashi; Kaneko, Katsumi

    2012-01-01

    We theoretically discuss X-ray absorption intensity in high-energy region far from the deepest core threshold to explain the morphology-dependent mass attenuation coefficient of some carbon systems, carbon nanotubes (CNTs), highly oriented pyrolytic graphite (HOPG) and fullerenes (C 60 ). The present theoretical approach is based on the many-body X-ray absorption theory including the intrinsic losses (shake-up losses). In the high-energy region the absorption coefficient has correction term dependent on the solid state effects given in terms of the polarization part of the screened Coulomb interaction W p . We also discuss the tail of the valence band X-ray absorption intensity. In the carbon systems C 2s contribution has some influence on the attenuation coefficient even in the high energy region at 20 keV.

  12. Determination of optical absorption coefficient with focusing photoacoustic imaging.

    Science.gov (United States)

    Li, Zhifang; Li, Hui; Zeng, Zhiping; Xie, Wenming; Chen, Wei R

    2012-06-01

    Absorption coefficient of biological tissue is an important factor for photothermal therapy and photoacoustic imaging. However, its determination remains a challenge. In this paper, we propose a method using focusing photoacoustic imaging technique to quantify the target optical absorption coefficient. It utilizes the ratio of the amplitude of the peak signal from the top boundary of the target to that from the bottom boundary based on wavelet transform. This method is self-calibrating. Factors, such as absolute optical fluence, ultrasound parameters, and Grüneisen parameter, can be canceled by dividing the amplitudes of the two peaks. To demonstrate this method, we quantified the optical absorption coefficient of a target with various concentrations of an absorbing dye. This method is particularly useful to provide accurate absorption coefficient for predicting the outcomes of photothermal interaction for cancer treatment with absorption enhancement.

  13. Light absorption and scattering mechanisms in laser fusion plasmas

    International Nuclear Information System (INIS)

    Barnes, C.; Estabrook, K.G.; Kruer, W.L.; Langdon, A.B.; Lasinski, B.F.; Max, C.E.; Randall, C.; Thomson, J.J.

    1977-01-01

    The picture of laser light absorption and scattering which is emerging from theory and computer simulation studies of laser-plasma interactions is described. On the subject of absorption, we discuss theoretical and experimental evidence that resonance absorption in a steepened density profile is a dominant absorption mechanism. Recent work also indicates the presence of critical surface ripples, which we study using two and three dimensional computer simulations. Predictions of hot electron spectra due to resonance absorption are described, as are effects of plasma outflow. We then discuss two regimes where stimulated scattering may occur. Brillouin scattering is expected in the underdense target blow-off, for long laser pulses, and is limited by ion heating. Raman scattering in the background gas of a reactor target chamber is predicted to be at most a 10 percent effect for 1 μm lasers

  14. Does lead use the intestinal absorptive pathways of iron? Impact of iron status on murine 210Pb and 59Fe absorption in duodenum and ileum in vivo

    International Nuclear Information System (INIS)

    Elsenhans, Bernd; Janser, Heinz; Windisch, Wilhelm; Schuemann, Klaus

    2011-01-01

    Highlights: → Absorption of 210 Pb increases much less than that of 59 Fe in murine duodena. → 210 Pb-absorption is almost equally high in murine duodenal and ileal segments. → 59 Fe absorption is much lower in ileal than in duodenal segments. → There must be an additional DMT1-independet pathway for intestinal Pb absorption. -- Abstract: Background: Human isotope studies and epidemiological trials are controversial as to whether lead absorption shares the absorptive pathways of iron and whether body lead content can be reduced by iron supplementation. Aim: To compare the impact of iron-deficiency on 59 Fe- and 210 Pb-absorption rates in duodenal and ileal segments. Methods: 59 Fe- and 210 Pb-absorption was determined in ligated duodenal and ileal segments from juvenile and adult iron-deficient and iron-adequate C57Bl6 wild-type mice (n = 6) in vivo at luminal concentrations corresponding to human exposure (Fe: 1 and 100 μmol/L; Pb: 1 μmol/L). Results and discussion: 59 Fe-absorption increased 10-15-fold in iron-deficient duodena from adult and adolescent mice. Ileal 59 Fe-absorption was 4-6 times lower than in iron-adequate duodena showing no adaptation to iron-deficiency. This in accordance to expectation as the divalent metal transport 1 (DMT1) shows low ileal expression levels. Juvenile 59 Fe-absorption was about twice as high as in adult mice. In contrast, duodenal 210 Pb-absorption was increased only 1.5-1.8-fold in iron-deficiency in juvenile and adult mice and, again in contrast to 59 Fe, ileal 210 Pb-absorption was as high as in iron-adequate duodena. Conclusions: The findings suggest a DMT1-independent pathway to mediate lead absorption along the entire small intestine in addition to DMT1-mediated duodenal uptake. Ileal lead absorption appears substantial, due the much longer residence of ingesta in the distal small intestine. Differences in lead-solubility and -binding to luminal ligands can, thus, explain the conflicting findings regarding the

  15. Water analysis. Determination of elements by atomic absorption

    International Nuclear Information System (INIS)

    Anon.

    Analysis of homogeneous water solutions (plain water, polluted waters, effluents...) by atomic absorption spectrometry with correction for non specific absorption. The quantity ratio is determined by comparison with standard solutions, correction tables are given [fr

  16. Absorptive products

    International Nuclear Information System (INIS)

    Assarsson, P.G.; King, P.A.

    1976-01-01

    Applications for hydrophile gels produced by the radiation induced cross-linking in aqueous solution of polyethylene oxide and starch, as described in Norwegian patent 133501 (INIS RN 281494), such as sanitary napkins (diapers) and sanitary towels, are discussed. The process itself is also discussed and results, expressed as the percentage of insoluble gel and its absorptive capacity for saline solution as functions of the ratio of polyethylene oxide to starch and the radiation dose, are presented. (JIW)

  17. Cosmological Evolution of QSO Absorption Systems

    Science.gov (United States)

    Stengler-Larrea, Erik

    1995-08-01

    First, the evolution with cosmic time of the hydrogen clouds which produce the Lyman-alpha absorption lines is studied in dependence on the strength of these lines. From the analysis it is concluded that the results show no evidence of a dependence in the sense of stronger lines evolving faster, although for the resolution at which the used observations were done, it can not be ruled out. Within the same analysis, a distribution of the Doppler parameter of the lines was obtained, with large values and a wide spread. This parameter being an indicator of the gas temperature, this result is in accordance with high temperatures and, consequently, large ionised fractions and a large fraction of the baryonic matter of the universe being associated with these clouds. However, recent high resolution studies seem to reveal that much lower temperatures are characteristic of the clouds. The main content of this thesis, however, focuses on the redshift evolution of the absorbing systems producing absorption at the Lyman limit and of the amount of CIV producing CIV absorption lines. Regarding the CIV absorbers, previous predictions on the effects underlying their redshift distribution pointed to an increase with redshift of the absorbing column densities. In this thesis the first direct measurements of such column densities by profile fitting of a large number of absorption systems (73) are presented, confirming the predictions of a decrease of at least a factor of 3 between z=1.5 and z=3.0. The study on the evolution of Lyman limit absorption systems (LLSs) puts an end to previous discrepancies between the results of different groups. Both a smooth single power law dependence of the LLS number density on redshift indicating no evolution in number density for 0.4 Team of the HST Key Project on QSO absorption lines, and in particular to estimate the necessary exposure times, the magnitudes of several of these objects had to be re-measured. The acquisition of their images and the

  18. Correction to the Beer-Lambert-Bouguer law for optical absorption.

    Science.gov (United States)

    Abitan, Haim; Bohr, Henrik; Buchhave, Preben

    2008-10-10

    The Beer-Lambert-Bouguer absorption law, known as Beer's law for absorption in an optical medium, is precise only at power densities lower than a few kW. At higher power densities this law fails because it neglects the processes of stimulated emission and spontaneous emission. In previous models that considered those processes, an analytical expression for the absorption law could not be obtained. We show here that by utilizing the Lambert W-function, the two-level energy rate equation model is solved analytically, and this leads into a general absorption law that is exact because it accounts for absorption as well as stimulated and spontaneous emission. The general absorption law reduces to Beer's law at low power densities. A criterion for its application is given along with experimental examples. (c) 2008 Optical Society of America

  19. Numerical study of surface plasmon enhanced nonlinear absorption and refraction.

    Science.gov (United States)

    Kohlgraf-Owens, Dana C; Kik, Pieter G

    2008-07-07

    Maxwell Garnett effective medium theory is used to study the influence of silver nanoparticle induced field enhancement on the nonlinear response of a Kerr-type nonlinear host. We show that the composite nonlinear absorption coefficient, beta(c), can be enhanced relative to the host nonlinear absorption coefficient near the surface plasmon resonance of silver nanoparticles. This enhancement is not due to a resonant enhancement of the host nonlinear absorption, but rather due to a phase shifted enhancement of the host nonlinear refractive response. The enhancement occurs at the expense of introducing linear absorption, alpha(c), which leads to an overall reduced figure of merit beta(c)/alpha(c) for nonlinear absorption. For thin (< 1 microm) composites, the use of surface plasmons is found to result in an increased nonlinear absorption response compared to that of the host material.

  20. Mid-IR Absorption Cross-Section Measurements of Hydrocarbons

    KAUST Repository

    Alrefae, Majed Abdullah

    2013-01-01

    -known at combustion-relevant conditions. Absorption cross-section is an important spectroscopic quantity and has direct relation to the species concentration. In this work, the absorption cross-sections of basic hydrocarbons are measured using Fourier Transform

  1. $J/\\psi$ Absorption in Heavy Ion Collisions

    CERN Document Server

    Maiani, Luciano; Polosa, Antonio; Riquer, V

    2004-01-01

    We present a new calculation of the pi-J/psi dissociation cross sections within the Constituent Quark-Meson Model recently introduced. To discuss the absorption of J/psi in heavy-ion collisions, we assume the J/psi to be produced inside a thermalized pion gas, as discussed by Bjorken, and introduce the corrections due to absorption by nuclear matter as well. We fit the absorption length of the J/psi to the data obtained at the CERN SPS by the NA50 Collaboration for Pb-Pb collisions. Collisions of lower centrality allow us to determine the temperature and the energy density of the pion gas. For both these quantities we find values close to those indicated by lattice gauge calculations for the transition to a quark-gluon plasma. A simple extrapolation to more central collisions, which takes into account the increase of the energy deposited due to the increased nucleon flux, fails to reproduce the break in J/psi absorption indicated by NA50, thus lending support to the idea that an unconfined quark-gluon phase m...

  2. Absorption-Edge-Modulated Transmission Spectra for Water Contaminant Monitoring

    Science.gov (United States)

    2016-03-31

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6390--16-9675 Absorption- Edge -Modulated Transmission Spectra for Water Contaminant...ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT Absorption- Edge -Modulated Transmission Spectra for Water Contaminant Monitoring...contaminants, within a volume of sampled solution, requires sufficient sensitivity. The present study examines the sensitivity of absorption- edge

  3. Use of a standard meal to study iron absorption in humans

    International Nuclear Information System (INIS)

    Reddy, M.B.; Cook, J.D.

    1994-01-01

    Iron absorption varies widely between subjects and groups of subjects because of differences in iron status which markedly influence iron assimilation from the gastrointestinal tract. A small dose of isotopically labelled inorganic iron termed the reference dose (3 mg iron as FeSO 4 ) has been used extensively during the past two decades to standardize food iron absorption in human subjects and thereby eliminate the effect of differences in iron status. Recent studies from this laboratory have shown that because of the high variability of absorption from the reference dose, nonheme iron absorption from a standardized meal provides a more reliable means of standardizing absorption from regional diets. We therefore performed initial studies with a rice based meal but we found a relatively high variation in absorption from 2.0 to 4.7% that presumably reflects differences in the phytate content of rice fours. We then undertook the evaluation of meals prepared with farina, a wheat product that is available in most regions of the world. In six different studies from a farina based meal, iron absorption ranged from 3.4 to 6.5%. Nonheme iron absorption from the farina meal when evaluated in separate laboratories extensively engaged in human studies of iron absorption, ranged from 5.1 to 10.8% but when related to the FeSO 4 dose, a more consistent ratio between 0.21 to 0.26 was observed with the exception of one laboratory where a very low absorption of 1.1.% was observed. Percentage absorption from the farina based meal decreased when the iron content of the meal was increased and showed the expected facilitation of absorption when increasing amounts of ascorbic acid were added. By reducing variability and measuring iron absorption from food rather than inorganic iron, we believe that the use of this standard meal will facilitate comparison of iron absorption data obtained in laboratories throughout the world. 4 refs, 2 tabs

  4. Rotational averaging of multiphoton absorption cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Friese, Daniel H., E-mail: daniel.h.friese@uit.no; Beerepoot, Maarten T. P.; Ruud, Kenneth [Centre for Theoretical and Computational Chemistry, University of Tromsø — The Arctic University of Norway, N-9037 Tromsø (Norway)

    2014-11-28

    Rotational averaging of tensors is a crucial step in the calculation of molecular properties in isotropic media. We present a scheme for the rotational averaging of multiphoton absorption cross sections. We extend existing literature on rotational averaging to even-rank tensors of arbitrary order and derive equations that require only the number of photons as input. In particular, we derive the first explicit expressions for the rotational average of five-, six-, and seven-photon absorption cross sections. This work is one of the required steps in making the calculation of these higher-order absorption properties possible. The results can be applied to any even-rank tensor provided linearly polarized light is used.

  5. A Review: Characteristics of Noise Absorption Material

    Science.gov (United States)

    Amares, S.; Sujatmika, E.; Hong, T. W.; Durairaj, R.; Hamid, H. S. H. B.

    2017-10-01

    Noise is always treated as a nuisance to human and even noise pollution appears in the environmental causing discomfort. This also concerns the engineering design that tends to cultivate this noise propagation. Solution such as using material to absorb the sound have been widely used. The fundamental of the sound absorbing propagation, sound absorbing characteristics and its factors are minimally debated. Furthermore, the method in order to pertain sound absorbing related to the sound absorption coefficient is also limited, as many studies only contributes in result basis and very little in literature aspect. This paper revolves in providing better insight on the importance of sound absorption and the materials factors in obtaining the sound absorption coefficient.

  6. Tunable electromagnetically induced absorption based on graphene

    Science.gov (United States)

    Cao, Maoyong; Wang, Tongling; Zhang, Huiyun; Zhang, Yuping

    2018-04-01

    In this paper, an electronically induced absorption (EIA) structure based on graphene at the infrared frequency is proposed. A pair of nanorods is coupled to a ring resonator, resulting in electronically induced transparency (EIT), and then, Babinet's principle is applied to transform the EIT structure into an EIA structure. Based on the bright and dark modes of the coupling schemes, the adjustment of the coupling strength between the dark and bright modes can be achieved by changing the asymmetry degree. In addition, the transparency window and the absorption peak can be tuned by changing the Fermi energy of graphene. This graphene-based EIA structure can develop the path in narrow-band filtering and, absorptive switching in the future.

  7. Measurement of Absorption Coefficient of Paraformaldehyde and Metaldehyde with Terahertz Spectroscopy

    Science.gov (United States)

    Zhang, J.; Xia, T.; Chen, Q.; Sun, Q.; Deng, Y.; Wang, C.

    2018-03-01

    The characteristic absorption spectra of paraformaldehyde and metaldehyde in the terahertz frequency region are obtained by terahertz time-domain spectroscopy (THz-TDS). In order to reduce the absorption of terahertz (THz) wave by water vapor in the air and the background noise, the measurement system was filled with dry air and the measurements were conducted at the temperature of 24°C. Meanwhile, the humidity was controlled within 10% RH. The THz frequency domain spectra of samples and their references from 0 to 2.5 THz were analyzed via Fourier transform. The refractive index and absorption coefficients of the two aldehydes were calculated by the model formulas. From 0.1 to 2.5 THz, there appear two weak absorption peaks at 1.20 and 1.66 THz in the absorption spectra of paraformaldehyde. Only one distinct absorption peak emerges at 1.83 THz for metaldehyde. There are significant differences between the terahertz absorption coefficients of paraformaldehyde and metaldehyde, which can be used as "fingerprints" to identify these substances. Furthermore, the relationship between the average absorption coefficients and mass concentrations was investigated and the average absorption coefficient-mass concentration diagrams of paraformaldehyde and metaldehyde were shown. For paraformaldehyde, there is a linear relationship between the average absorption coefficient and the natural logarithm of mass concentration. For metaldehyde, there exists a simpler linear relationship between the average absorption coefficient and the mass concentration. Because of the characteristics of THz absorption of paraformaldehyde and metaldehyde, the THz-TDS can be applied to the qualitative and quantitative detection of the two aldehydes to reduce the unpredictable hazards due to these substances.

  8. Process for neptunium analysis by absorption spectrophotometry

    International Nuclear Information System (INIS)

    Wagner, J.F.

    1987-01-01

    An aqueous solution of a neptunium compounds is treated by a reagent, preferentially a vanadyl sulfate oxidized by cerium IV ions, to obtain neptunium V by oxidation of neptunium IV and reduction of neptunium VI. The reagent is chosen for a negligible absorption at the wavelength used for neptunium V absorption spectrophotometry for instance 981 nm [fr

  9. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  10. Vitamin B12 absorption capacity in healthy children

    International Nuclear Information System (INIS)

    Hjelt, K.; Krasilnikoff, P.A.

    1986-01-01

    B12 absorption was investigated in 47 healthy children aged 7 months to 15.8 years (median 4.9 years). The patients had either recovered from giardiasis, the post-gastroenteritis syndrome, or had celiac disease in remission (treated with a gluten-free diet). The B12 absorption was measured by a double-isotope technique using 57 CoB12 and 51 CrCl 3 , the latter being the inabsorbable marker. The radiation dose was minimal. The results were presented as fractional absorption of B12 (FAB12). Within the different age groups, the absorption test was performed by means of the following oral amounts of B12: 0- less than 1 year, 0.5 microgram; 1-3 years: 1.7 micrograms, 4-6 years, 2.5 micrograms; 7-10 years; 3.3 micrograms; and 11-15 years, 4.5 micrograms. When using these oral amounts of B12, the medians (and ranges) of FAB12 were found to be: 1-3 years (n = 18), 37% (16-80%); 4-6 years (n = 10), 27% (19-40%); 7-10 years (n = 9), 32% (21-44%); and 11-15 years (n = 8), 27% (19-59%). The FAB12 in two children aged 7 and 11 months was 31% and 32%, respectively. These results may be interpretated as reference values for B12 absorption in children. Further absorption tests were performed in seven children representing the four age groups from 1 to 15 years. When a high oral amount of B12 was given (i.e., three times the saturation dose), the FAB12 ranged from 0 to 20% (median 9%), whereas a low amount (i.e., one-ninth of the saturation dose) produced fractional absorptions from 65 to 82% (median 74%)

  11. Vitamin B12 absorption capacity in healthy children

    Energy Technology Data Exchange (ETDEWEB)

    Hjelt, K.; Krasilnikoff, P.A.

    1986-03-01

    B12 absorption was investigated in 47 healthy children aged 7 months to 15.8 years (median 4.9 years). The patients had either recovered from giardiasis, the post-gastroenteritis syndrome, or had celiac disease in remission (treated with a gluten-free diet). The B12 absorption was measured by a double-isotope technique using /sup 57/CoB12 and /sup 51/CrCl/sub 3/, the latter being the inabsorbable marker. The radiation dose was minimal. The results were presented as fractional absorption of B12 (FAB12). Within the different age groups, the absorption test was performed by means of the following oral amounts of B12: 0- less than 1 year, 0.5 microgram; 1-3 years: 1.7 micrograms, 4-6 years, 2.5 micrograms; 7-10 years; 3.3 micrograms; and 11-15 years, 4.5 micrograms. When using these oral amounts of B12, the medians (and ranges) of FAB12 were found to be: 1-3 years (n = 18), 37% (16-80%); 4-6 years (n = 10), 27% (19-40%); 7-10 years (n = 9), 32% (21-44%); and 11-15 years (n = 8), 27% (19-59%). The FAB12 in two children aged 7 and 11 months was 31% and 32%, respectively. These results may be interpretated as reference values for B12 absorption in children. Further absorption tests were performed in seven children representing the four age groups from 1 to 15 years. When a high oral amount of B12 was given (i.e., three times the saturation dose), the FAB12 ranged from 0 to 20% (median 9%), whereas a low amount (i.e., one-ninth of the saturation dose) produced fractional absorptions from 65 to 82% (median 74%).

  12. Paracellular absorption: a bat breaks the mammal paradigm.

    Directory of Open Access Journals (Sweden)

    Enrique Caviedes-Vidal

    Full Text Available Bats tend to have less intestinal tissue than comparably sized nonflying mammals. The corresponding reduction in intestinal volume and hence mass of digesta carried is advantageous because the costs of flight increase with load carried and because take-off and maneuverability are diminished at heavier masses. Water soluble compounds, such as glucose and amino acids, are absorbed in the small intestine mainly via two pathways, the transporter-mediated transcellular and the passive, paracellular pathways. Using the microchiropteran bat Artibeus literatus (mean mass 80.6+/-3.7 g, we tested the predictions that absorption of water-soluble compounds that are not actively transported would be extensive as a compensatory mechanism for relatively less intestinal tissue, and would decline with increasing molecular mass in accord with sieve-like paracellular absorption. Using a standard pharmacokinetic technique, we fed, or injected intraperitoneally the metabolically inert carbohydrates L-rhamnose (molecular mass = 164 Da and cellobiose (molecular mass = 342 Da which are absorbed only by paracellular transport, and 3-O-methyl-D-glucose (3OMD-glucose which is absorbed via both mediated (active and paracellular transport. As predicted, the bioavailability of paracellular probes declined with increasing molecular mass (rhamnose, 90+/-11%; cellobiose, 10+/-3%, n = 8 and was significantly higher in bats than has been reported for laboratory rats and other mammals. In addition, absorption of 3OMD-glucose was high (96+/-11%. We estimated that the bats rely on passive, paracellular absorption for more than 70% of their total glucose absorption, much more than in non-flying mammals. Although possibly compensating for less intestinal tissue, a high intestinal permeability that permits passive absorption might be less selective than a carrier-mediated system for nutrient absorption and might permit toxins to be absorbed from plant and animal material in the

  13. Compressive Behaviour and Energy Absorption of Aluminium Foam Sandwich

    Science.gov (United States)

    Endut, N. A.; Hazza, M. H. F. Al; Sidek, A. A.; Adesta, E. T. Y.; Ibrahim, N. A.

    2018-01-01

    Development of materials in automotive industries plays an important role in order to retain the safety, performance and cost. Metal foams are one of the idea to evolve new material in automotive industries since it can absorb energy when it deformed and good for crash management. Recently, new technology had been introduced to replace metallic foam by using aluminium foam sandwich (AFS) due to lightweight and high energy absorption behaviour. Therefore, this paper provides reliable data that can be used to analyze the energy absorption behaviour of aluminium foam sandwich by conducting experimental work which is compression test. Six experiments of the compression test were carried out to analyze the stress-strain relationship in terms of energy absorption behavior. The effects of input variables include varying the thickness of aluminium foam core and aluminium sheets on energy absorption behavior were evaluated comprehensively. Stress-strain relationship curves was used for energy absorption of aluminium foam sandwich calculation. The result highlights that the energy absorption of aluminium foam sandwich increases from 12.74 J to 64.42 J respectively with increasing the foam and skin thickness.

  14. Near-infrared free carrier absorption in heavily doped silicon

    International Nuclear Information System (INIS)

    Baker-Finch, Simeon C.; McIntosh, Keith R.; Yan, Di; Fong, Kean Chern; Kho, Teng C.

    2014-01-01

    Free carrier absorption in heavily doped silicon can have a significant impact on devices operating in the infrared. In the near infrared, the free carrier absorption process can compete with band to band absorption processes, thereby reducing the number of available photons to optoelectronic devices such as solar cells. In this work, we fabricate 18 heavily doped regions by phosphorus and boron diffusion into planar polished silicon wafers; the simple sample structure facilitates accurate and precise measurement of the free carrier absorptance. We measure and model reflectance and transmittance dispersion to arrive at a parameterisation for the free carrier absorption coefficient that applies in the wavelength range between 1000 and 1500 nm, and the range of dopant densities between ∼10 18 and 3 × 10 20  cm −3 . Our measurements indicate that previously published parameterisations underestimate the free carrier absorptance in phosphorus diffusions. On the other hand, published parameterisations are generally consistent with our measurements and model for boron diffusions. Our new model is the first to be assigned uncertainty and is well-suited to routine device analysis

  15. Credibility judgments of narratives: language, plausibility, and absorption.

    Science.gov (United States)

    Nahari, Galit; Glicksohn, Joseph; Nachson, Israel

    2010-01-01

    Two experiments were conducted in order to find out whether textual features of narratives differentially affect credibility judgments made by judges having different levels of absorption (a disposition associated with rich visual imagination). Participants in both experiments were exposed to a textual narrative and requested to judge whether the narrator actually experienced the event he described in his story. In Experiment 1, the narrative varied in terms of language (literal, figurative) and plausibility (ordinary, anomalous). In Experiment 2, the narrative varied in terms of language only. The participants' perceptions of the plausibility of the story described and the extent to which they were absorbed in reading were measured. The data from both experiments together suggest that the groups applied entirely different criteria in credibility judgments. For high-absorption individuals, their credibility judgment depends on the degree to which the text can be assimilated into their own vivid imagination, whereas for low-absorption individuals it depends mainly on plausibility. That is, high-absorption individuals applied an experiential mental set while judging the credibility of the narrator, whereas low-absorption individuals applied an instrumental mental set. Possible cognitive mechanisms and implications for credibility judgments are discussed.

  16. Development of an Ionic-Liquid Absorption Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, Don

    2011-03-29

    Solar Fueled Products (SFP) is developing an innovative ionic-liquid absorption heat pump (ILAHP). The development of an ILAHP is extremely significant, as it could result in annual savings of more than 190 billion kW h of electrical energy and $19 billion. This absorption cooler uses about 75 percent less electricity than conventional cooling and heating units. The ILAHP also has significant environmental sustainability benefits, due to reduced CO2 emissions. Phase I established the feasibility and showed the economic viability of an ILAHP with these key accomplishments: • Used the breakthrough capabilities provided by ionic liquids which overcome the key difficulties of the common absorption coolers. • Showed that the theoretical thermodynamic performance of an ILAHP is similar to existing absorption-cooling systems. • Established that the half-effect absorption cycle reduces the peak generator temperature, improving collector efficiency and reducing collector area. • Component testing demonstrated that the most critical components, absorber and generator, operate well with conventional heat exchangers. • Showed the economic viability of an ILAHP. The significant energy savings, sustainability benefits, and economic viability are compelling reasons to continue the ILAHP development.

  17. Exciton absorption of entangled photons in semiconductor quantum wells

    Science.gov (United States)

    Rodriguez, Ferney; Guzman, David; Salazar, Luis; Quiroga, Luis; Condensed Matter Physics Group Team

    2013-03-01

    The dependence of the excitonic two-photon absorption on the quantum correlations (entanglement) of exciting biphotons by a semiconductor quantum well is studied. We show that entangled photon absorption can display very unusual features depending on space-time-polarization biphoton parameters and absorber density of states for both bound exciton states as well as for unbound electron-hole pairs. We report on the connection between biphoton entanglement, as quantified by the Schmidt number, and absorption by a semiconductor quantum well. Comparison between frequency-anti-correlated, unentangled and frequency-correlated biphoton absorption is addressed. We found that exciton oscillator strengths are highly increased when photons arrive almost simultaneously in an entangled state. Two-photon-absorption becomes a highly sensitive probe of photon quantum correlations when narrow semiconductor quantum wells are used as two-photon absorbers. Research funds from Facultad de Ciencias, Universidad de los Andes

  18. Optical absorption of hyperbolic metamaterial with stochastic surfaces

    DEFF Research Database (Denmark)

    Liu, Jingjing; Naik, Gururaj V.; Ishii, Satoshi

    2014-01-01

    We investigate the absorption properties of planar hyperbolic metamaterials (HMMs) consisting of metal-dielectric multilayers, which support propagating plane waves with anomalously large wavevectors and high photonic-density-of-states over a broad bandwidth. An interface formed by depositing...... indium-tin-oxide nanoparticles on an HMM surface scatters light into the high-k propagating modes of the metamaterial and reduces reflection. We compare the reflection and absorption from an HMM with the nanoparticle cover layer versus those of a metal film with the same thickness also covered...... with the nanoparticles. It is predicted that the super absorption properties of HMM show up when exceedingly large amounts of high-k modes are excited by strong plasmonic resonances. In the case that the coupling interface is formed by non-resonance scatterers, there is almost the same enhancement in the absorption...

  19. Effects of iron, tin, and copper on zinc absorption in humans

    International Nuclear Information System (INIS)

    Valberg, L.S.; Flanagan, P.R.; Chamberlain, M.J.

    1984-01-01

    Zinc absorption as measured by body retention of [65Zn]zinc chloride or a turkey test meal extrinsically labeled with 65Zn was determined in human subjects by whole body counting after 7 days. Average 65Zn absorption from zinc chloride in persons with a high iron-absorbing capacity was similar to persons with a low capacity to absorb iron. Inorganic iron, 920 mumol (51 mg), or HB iron, 480 mumol (26 mg), inhibited 65Zn absorption from 92 mumol (6 mg) of zinc chloride. When 610 mumol of iron (34 mg) was added to a turkey test meal containing 61 mumol of zinc (4 mg), 65Zn absorption was not inhibited. Tin, 306 mumol (36 mg), given with zinc chloride or turkey test meals (61 mumol, 4 mg, of Zn) significantly reduced 65Zn absorption. Copper, 79 mumol (5 mg), had no significant effect on the 65Zn absorption from 7.9 mumol (0.5 mg) of zinc chloride. In summary, the capacity to absorb iron did not influence 65Zn absorption, but both inorganic iron and heme-iron inhibited 65Zn absorption from zinc chloride. Inorganic iron had no effect, however, on 65Zn absorption from the turkey test meal. Tin in a large dose also inhibited 65Zn absorption from both zinc chloride and the turkey test meal

  20. Narrow absorption lines complex I: one form of broad absorption line

    Science.gov (United States)

    Lu, Wei-Jian; Lin, Ying-Ru

    2018-03-01

    We discover that some of the broad absorption lines (BALs) are actually a complex of narrow absorption lines (NALs). As a pilot study of this type of BAL, we show this discovery through a typical example in this paper. Utilizing the two-epoch observations of J002710.06-094435.3 (hereafter J0027-0944) from the Sloan Digital Sky Survey (SDSS), we find that each of the C IV and Si IV BAL troughs contains at least four NAL doublets. By resolving the Si IV BAL into multiple NALs, we present the following main results and conclusions. First, all these NALs show coordinated variations between the two-epoch SDSS observations, suggesting that they all originate in the quasar outflow, and that their variations are due to global changes in the ionization condition of the absorbing gas. Secondly, a BAL consisting of a number of NAL components indicates that this type of BAL is basically the same as the intrinsic NAL, which tends to support the inclination model rather than the evolution model. Thirdly, although both the C IV and Si IV BALs originate from the same clumpy substructures of the outflow, they show different profile shapes: multiple absorption troughs for the Si IV BAL in a wider velocity range, while P-Cygni for the C IV BAL in a narrower velocity range. This can be interpreted by the substantial differences in fine structure and oscillator strength between the Si IVλλ1393, 1402 and C IVλλ1548, 1551 doublets. Based on the above conclusions, we consider that the decomposition of a BAL into NALs can serve as a way to resolve the clumpy structure for outflows, and it can be used to learn more about characteristics of the clumpy structure and to test the outflow model, when utilizing high-resolution spectra and photoionization model.

  1. Intrinsic defect oriented visible region absorption in zinc oxide films

    Science.gov (United States)

    Rakhesh, V.; Shankar, Balakrishnan

    2018-05-01

    Zinc Oxide films were deposited on the glass substrate using vacuum arc sputtering technology. Films were prepared in oxygen ambience for 10mA and 15 mA deposition current separately. The UV-Visible spectroscopy of the samples showed that both samples possess sharp absorption near 3.5eV which is the characteristic band gap absorption energy of ZnO films. The absorption coefficient were calculated for the samples and the (αℎϑ)2 vs energy plot is drawn. The plot suggested that in addition to the sharp band edge absorption, the sample prepared at 10mA deposition current showed sharp absorption edge near 1.51eV and that at 15 mA showed absorption edge near 1.47eV. This refers to the presence of an intrinsic defect level which is likely to be deep in the band gap.

  2. Water vapor absorption of carbon dioxide laser radiation

    Science.gov (United States)

    Shumate, M. S.; Menzies, R. T.; Margolis, J. S.; Rosengren, L.-G.

    1976-01-01

    An optoacoustic detector or spectrophone has been used to perform detailed measurements of the absorptivity of mixtures of water vapor in air. A (C-12) (O-16)2 laser was used as the source, and measurements were made at forty-nine different wavelengths from 9.2 to 10.7 microns. The details of the optoacoustic detector and its calibration are presented, along with a discussion of its performance characteristics. The results of the measurements of water vapor absorption show that the continuum absorption in the wavelength range covered is 5-10% lower than previous measurements.

  3. Exciton molecule in semiconductors by two-photon absorption

    International Nuclear Information System (INIS)

    Arya, K.; Hassan, A.R.

    1976-07-01

    Direct creation of bi-exciton states by two-photon absorption in direct gap semiconductors is investigated theoretically. A numerical application to the case of CuCl shows that the two-photon absorption coefficient for bi-excitonic transitions is larger than that for two-photon interband transitions by three orders of magnitude. It becomes comparable to that for one-photon excitonic transitions for available laser intensities. The main contribution to this enhancement of the absorption coefficient for the transitions to the bi-exciton states is found to be from the resonance effect

  4. Photon absorption of calcium phosphate-based dental biomaterials

    International Nuclear Information System (INIS)

    Singh, V. P.; Badiger, N. M.; Tekin, H. O.; Kara, U.; Vega C, H. R.; Fernandes Z, M. A.

    2017-10-01

    Effective atomic number and mass energy absorption buildup factors for four calcium phosphate-based biomaterials used in dental treatments were calculated for 0.015 to 15 MeV photons. The mass energy absorption coefficients were calculated for 0.5 to 40 mean free paths of photons. In the energy region important for dental radiology the Zeff for all studied biomaterials are larger in comparison to larger energies. In x-rays for dental radiology and the energy absorption buildup factors are low, however CbMDI bio material shows a resonance at 80 keV. (Author)

  5. Mass: Fortran program for calculating mass-absorption coefficients

    International Nuclear Information System (INIS)

    Nielsen, Aa.; Svane Petersen, T.

    1980-01-01

    Determinations of mass-absorption coefficients in the x-ray analysis of trace elements are an important and time consuming part of the arithmetic calculation. In the course of time different metods have been used. The program MASS calculates the mass-absorption coefficients from a given major element analysis at the x-ray wavelengths normally used in trace element determinations and lists the chemical analysis and the mass-absorption coefficients. The program is coded in FORTRAN IV, and is operational on the IBM 370/165 computer, on the UNIVAC 1110 and on PDP 11/05. (author)

  6. Development and comparison of different advanced absorption cycles

    Energy Technology Data Exchange (ETDEWEB)

    Arh, S; Gaspersic, B [Faculty of Mechanical Engineering, Ljubjana (YU)

    1990-01-01

    A method for the calculation of the coefficient of performance for any absorption cycle is described. This method was used for the evaluation of different advanced absorption cycles working between four temperature and two or three pressure levels. Similar cycles were compared in the same temperature range with regard to the coefficient of performance, exergy efficiency and two working fluid pairs, NH{sub 3}-H{sub 2}O and H{sub 2}O-LiBr. Cycles and numerical results are presented and a computer-aided absorption cycle development system described. (author).

  7. Pavement sound absorption measurements in the U.S.

    Science.gov (United States)

    2012-08-19

    In the U.S., the topic of pavement sound absorption in regard to tire-pavement noise has shown increased interest and research over the last several years. Four types of pavement sound absorption measurements with various applications are discussed: ...

  8. Absorption by Spinning Dust: A Contaminant for High-redshift 21 cm Observations

    Science.gov (United States)

    Draine, B. T.; Miralda-Escudé, Jordi

    2018-05-01

    Spinning dust grains in front of the bright Galactic synchrotron background can produce a weak absorption signal that could affect measurements of high-redshift 21 cm absorption. At frequencies near 80 MHz where the Experiment to Detect the Global EoR Signature (EDGES) has reported 21 cm absorption at z≈ 17, absorption could be produced by interstellar nanoparticles with radii a≈ 50 \\mathringA in the cold interstellar medium (ISM), with rotational temperature T ≈ 50 K. Atmospheric aerosols could contribute additional absorption. The strength of the absorption depends on the abundance of such grains and on their dipole moments, which are uncertain. The breadth of the absorption spectrum of spinning dust limits its possible impact on measurement of a relatively narrow 21 cm absorption feature.

  9. Parameter study of self-absorption effects in Total Reflection X-ray Fluorescence-X-ray Absorption Near Edge Structure analysis of arsenic

    International Nuclear Information System (INIS)

    Meirer, F.; Pepponi, G.; Streli, C.; Wobrauschek, P.; Kregsamer, P.; Zoeger, N.; Falkenberg, G.

    2008-01-01

    Total reflection X-ray Fluorescence (TXRF) analysis in combination with X-ray Absorption Near Edge Structure (XANES) analysis is a powerful method to perform chemical speciation studies at trace element levels. However, when measuring samples with higher concentrations and in particular standards, damping of the oscillations is observed. In this study the influence of self-absorption effects on TXRF-XANES measurements was investigated by comparing measurements with theoretical calculations. As(V) standard solutions were prepared at various concentrations and dried on flat substrates. The measurements showed a correlation between the damping of the oscillations and the As mass deposited. A Monte-Carlo simulation was developed using data of the samples shapes obtained from confocal white light microscopy. The results showed good agreement with the measurements; they confirmed that the key parameters are the density of the investigated atom in the dried residues and the shape of the residue, parameters that combined define the total mass crossed by a certain portion of the incident beam. The study presents a simple approach for an a priori evaluation of the self-absorption in TXRF X-ray absorption studies. The consequences for Extended X-ray Absorption Fine Structure (EXAFS) and XANES measurements under grazing incidence conditions are discussed, leading to the conclusion that the damping of the oscillations seems to make EXAFS of concentrated samples non feasible. For XANES 'fingerprint' analysis samples should be prepared with a deposited mass and sample shape leading to an acceptable absorption for the actual investigation

  10. 21 CFR 862.2850 - Atomic absorption spectrophotometer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Atomic absorption spectrophotometer for clinical... Laboratory Instruments § 862.2850 Atomic absorption spectrophotometer for clinical use. (a) Identification. An atomic absorption spectrophotometer for clinical use is a device intended to identify and measure...

  11. Gastrointestinal drug absorption in rats exposed to 60Co γ-radiation

    International Nuclear Information System (INIS)

    Brady, M.E.

    1976-01-01

    Following exposure of the gastrointestinal (GI) tract to ionizing radiation, its structure and function are altered for several days. Such alterations may affect the bioavailability of orally administered drugs. The potential mechanisms by which radiation may affect drug absorption were explored by studying the absorption of four test drugs, sulfanilamide, bretylium, sulfisoxazole acetyl, and riboflavin, in rats that were exposed to 850 R cobalt-60 gamma-radiation or sham irradiated. In one series of experiments, the drugs were administered orally and the amount of drug excreted in urine was used as a measure of the extent of their absorption. Cumulative urinary excretion of the drugs was shown to be a valid measure of absorption since it was not affected by radiation after intravenous administration of the drugs. At one day post-irradiation, the extent of absorption of sulfanilamide and bretylium was not affected by radiation but the absorption of sulfisoxazole acetyl and riboflavin was increased. At five days post-irradiation, there was no detectable difference between irradiated and control animals in the extent of absorption of the drugs. The fraction of sulfanilamide excreted in the urine as 4 N-conjugate was increased at one day post-irradiation. The increased excretion of metabolite appeared to result from metabolism of the drug by gut flora prior to absorption. This study shows that radiation-induced alterations in the absorption of orally administered drugs are due primarily to slowed gastric emptying. In general, slowed gastric emptying causes the rate of drug absorption to decline. The extent of absorption of drugs that are normally well absorbed is not affected by radiation while the extent of absorption of drugs that normally are absorbed poorly may be increased after irradiation of the GI tract

  12. Factors affecting the absorption and excretion of lead in the rat

    International Nuclear Information System (INIS)

    Conrad, M.E.; Barton, J.C.

    1978-01-01

    A reliable method for studying lead absorption and excretion in rats is described. Lead absorption occurs primarily in the duodenum where lead enters the epithelial mucosal cells. There is a relative mucosal block for lead with increasing intraluminal doses. Certain substances which bind lead and increase its solubility enhance its absorption. Iron, zinc, and calcium decrease the absorption of lead without affecting its solubility, probably by competing for shared absorptive receptors in the intestinal mucosa. The total body burden of lead does not affect lead absorption. Thus, lead does not have a feedback mechanism which limits absorption. Lead absorption is increased during rapid periods of growth and in iron-deficient animals. It is diminished with starvation and in iron-overloaded animals. The excretion and kinetics of tracer doses of radiolead were quantified. Erythrocytes seem to serve an important role in transport. Excretion occurs in urine and stool. Bile is an important route of excretion in the gut. Although most of a tracer dose is rapidly excreted, the excretory process is limited permitting lead accumulation primarily in bone

  13. Anomalous water absorption in porous materials

    CERN Document Server

    Lockington, D A

    2003-01-01

    The absorption of fluid by unsaturated, rigid porous materials may be characterized by the sorptivity. This is a simple parameter to determine and is increasingly being used as a measure of a material's resistance to exposure to fluids (especially moisture and reactive solutes) in aggressive environments. The complete isothermal absorption process is described by a nonlinear diffusion equation, with the hydraulic diffusivity being a strongly nonlinear function of the degree of saturation of the material. This diffusivity can be estimated from the sorptivity test. In a typical test the cumulative absorption is proportional to the square root of time. However, a number of researchers have observed deviation from this behaviour when the infiltrating fluid is water and there is some potential for chemo-mechanical interaction with the material. In that case the current interpretation of the test and estimation of the hydraulic diffusivity is no longer appropriate. Kuentz and Lavallee (2001) discuss the anomalous b...

  14. Gastrointestinal absorption of soluble uranium from drinking water. Published paper

    International Nuclear Information System (INIS)

    Wrenn, M.E.; Singh, N.P.; Ruth, H.; Burleigh, D.

    1988-04-01

    This manuscript describes results of an experiment to determine the gastrointestinal absorption of uranium from drinking water in 12 health adults. Most of the uranium ingested was excreted in feces in the first 2 days following ingestion of the water. The absorption was the same for (234)U and (238)U for each subject. Absorption varied among subjects from -0.02% to 2.6%, with a mean of 0.6%. Low absorption may be due to concurrent ingestion of food

  15. Cimetidine absorption in humans during sucralfate coadministration.

    OpenAIRE

    D'Angio, R; Mayersohn, M; Conrad, K A; Bliss, M

    1986-01-01

    Cimetidine absorption after a single 300 mg oral dose was evaluated in six normal subjects in the absence or presence of sucralfate. Sucralfate was ingested four times a day for 2 days prior to and for two additional doses on the day of cimetidine ingestion. Sucralfate coadministration had no statistically significant influence on the rate or extent of cimetidine absorption.

  16. Improvement of intestinal absorption of forsythoside A in weeping forsythia extract by various absorption enhancers based on tight junctions.

    Science.gov (United States)

    Zhou, Wei; Qin, Kun Ming; Shan, Jin Jun; Ju, Wen Zheng; Liu, Shi Jia; Cai, Bao Chang; Di, Liu Qing

    2012-12-15

    Forsythoside A (FTA), one of the main active ingredients in weeping forsythia extract, possesses strong antibacterial, antioxidant and antiviral effects, and its content was about 8% of totally, higher largely than that of other ingredients, but the absolute bioavailability orally was approximately 0.5%, which is significant low influencing clinical efficacies of its oral preparations. In the present study, in vitro Caco-2 cell, in situ single-pass intestinal perfusion and in vivo pharmacokinetics study were performed to investigate the effects of absorption enhancers based on tight junctions: sodium caprate and water-soluble chitosan on the intestinal absorption of FTA, and the eventual mucosal epithelial damage resulted from absorption enhancers was evaluated by MTT test, measurement of total amount of protein and the activity of LDH and morphology observation, respectively. The pharmacological effects such as antioxidant activity improvement by absorption enhancers were verified by PC12 cell damage inhibition rate after H₂O₂ insults. The observations from in vitro Caco-2 cell showed that the absorption of FTA in weeping forsythia extract could be improved by absorption enhancers. Meanwhile, the absorption enhancing effect of water-soluble chitosan may be almost saturable up to 0.0032% (w/v), and sodium caprate at concentrations up to 0.64 mg/ml was safe for the Caco-2 cells, but water-soluble chitosan at different concentrations was all safe for these cells. The observations from single-pass intestinal perfusion in situ model showed that duodenum, jejunum, ileum and colon showed significantly concentration-dependent increase in P(eff)-value, and that P(eff)-value in the ileum and colon groups, where sodium caprate was added, was higher than that of duodenum and jejunum groups, but P(eff)-value in the jejunum group was higher than that of duodenum, ileum and colon groups where water-soluble chitosan was added. Intestinal mucosal toxicity studies showed no

  17. Enhancing effect of bile salts on gastrointestinal absorption of insulin ...

    African Journals Online (AJOL)

    Purpose: To investigate the effect of co-administration of two absorption enhancing bile alts, sodium glycocholate (NaGc) and sodium salicylate (NaSal), on insulin absorption via intestinal targeted delivery system. Methods: Insulin (10 IU/kg), associated with and without absorption enhancers (5 % enhancer solution of ...

  18. Protein Hydrolysates as Promoters of Non-Haem Iron Absorption

    Science.gov (United States)

    Li, Yanan; Jiang, Han; Huang, Guangrong

    2017-01-01

    Iron (Fe) is an essential micronutrient for human growth and health. Organic iron is an excellent iron supplement due to its bioavailability. Both amino acids and peptides improve iron bioavailability and absorption and are therefore valuable components of iron supplements. This review focuses on protein hydrolysates as potential promoters of iron absorption. The ability of protein hydrolysates to chelate iron is thought to be a key attribute for the promotion of iron absorption. Iron-chelatable protein hydrolysates are categorized by their absorption forms: amino acids, di- and tri-peptides and polypeptides. Their structural characteristics, including their size and amino acid sequence, as well as the presence of special amino acids, influence their iron chelation abilities and bioavailabilities. Protein hydrolysates promote iron absorption by keeping iron soluble, reducing ferric iron to ferrous iron, and promoting transport across cell membranes into the gut. We also discuss the use and relative merits of protein hydrolysates as iron supplements. PMID:28617327

  19. Absorption and emission spectroscopic characterisation of 8-amino-riboflavin

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, A.; Zirak, P. [Institut II - Experimentelle und Angewandte Physik, Universitaet Regensburg, Universitaetsstrasse 31, D-93053 Regensburg (Germany); Penzkofer, A., E-mail: alfons.penzkofer@physik.uni-regensburg.de [Institut II - Experimentelle und Angewandte Physik, Universitaet Regensburg, Universitaetsstrasse 31, D-93053 Regensburg (Germany); Mathes, T.; Hegemann, P. [Institut fuer Biologie/Experimentelle Biophysik, Humboldt Universitaet zu Berlin, Invalidenstrasse 42, D-10115 Berlin (Germany); Mack, M. [Institut fuer Technische Mikrobiologie, Hochschule Mannheim, Paul-Wittsack-Str. 10, D-68163 Mannheim (Germany); Ghisla, S. [Universitaet Konstanz, Fakultaet fuer Biologie, P.O. Box 5560-M644, D-78457 Konstanz (Germany)

    2009-10-16

    The flavin dye 8-amino-8-demethyl-D-riboflavin (AF) in the solvents water, DMSO, methanol, and chloroform/DMSO was studied by absorption and fluorescence spectroscopy. The first absorption band is red-shifted compared to riboflavin, and blue-shifted compared to roseoflavin (8-dimethylamino-8-demethyl-D-riboflavin). The fluorescence quantum yield of AF in the studied solvents varies between 20% and 50%. The fluorescence lifetimes were found to be in the 2-5 ns range. AF is well soluble in DMSO, weakly soluble in water and methanol, and practically insoluble in chloroform. The limited solubility causes AF aggregation, which was seen in differences between measured absorption spectra and fluorescence excitation spectra. Light scattering in the dye absorption region is discussed and approximate absorption cross-section spectra are determined from the combined measurement of transmission and fluorescence excitation spectra. The photo-stability of AF was studied by prolonged light exposure. The photo-degradation routes of AF are discussed.

  20. Absorption and emission spectroscopic characterisation of 8-amino-riboflavin

    Science.gov (United States)

    Tyagi, A.; Zirak, P.; Penzkofer, A.; Mathes, T.; Hegemann, P.; Mack, M.; Ghisla, S.

    2009-10-01

    The flavin dye 8-amino-8-demethyl- D-riboflavin (AF) in the solvents water, DMSO, methanol, and chloroform/DMSO was studied by absorption and fluorescence spectroscopy. The first absorption band is red-shifted compared to riboflavin, and blue-shifted compared to roseoflavin (8-dimethylamino-8-demethyl-D-riboflavin). The fluorescence quantum yield of AF in the studied solvents varies between 20% and 50%. The fluorescence lifetimes were found to be in the 2-5 ns range. AF is well soluble in DMSO, weakly soluble in water and methanol, and practically insoluble in chloroform. The limited solubility causes AF aggregation, which was seen in differences between measured absorption spectra and fluorescence excitation spectra. Light scattering in the dye absorption region is discussed and approximate absorption cross-section spectra are determined from the combined measurement of transmission and fluorescence excitation spectra. The photo-stability of AF was studied by prolonged light exposure. The photo-degradation routes of AF are discussed.

  1. Absorption and emission spectroscopic characterisation of 8-amino-riboflavin

    International Nuclear Information System (INIS)

    Tyagi, A.; Zirak, P.; Penzkofer, A.; Mathes, T.; Hegemann, P.; Mack, M.; Ghisla, S.

    2009-01-01

    The flavin dye 8-amino-8-demethyl-D-riboflavin (AF) in the solvents water, DMSO, methanol, and chloroform/DMSO was studied by absorption and fluorescence spectroscopy. The first absorption band is red-shifted compared to riboflavin, and blue-shifted compared to roseoflavin (8-dimethylamino-8-demethyl-D-riboflavin). The fluorescence quantum yield of AF in the studied solvents varies between 20% and 50%. The fluorescence lifetimes were found to be in the 2-5 ns range. AF is well soluble in DMSO, weakly soluble in water and methanol, and practically insoluble in chloroform. The limited solubility causes AF aggregation, which was seen in differences between measured absorption spectra and fluorescence excitation spectra. Light scattering in the dye absorption region is discussed and approximate absorption cross-section spectra are determined from the combined measurement of transmission and fluorescence excitation spectra. The photo-stability of AF was studied by prolonged light exposure. The photo-degradation routes of AF are discussed.

  2. Protein Hydrolysates as Promoters of Non-Haem Iron Absorption

    Directory of Open Access Journals (Sweden)

    Yanan Li

    2017-06-01

    Full Text Available Iron (Fe is an essential micronutrient for human growth and health. Organic iron is an excellent iron supplement due to its bioavailability. Both amino acids and peptides improve iron bioavailability and absorption and are therefore valuable components of iron supplements. This review focuses on protein hydrolysates as potential promoters of iron absorption. The ability of protein hydrolysates to chelate iron is thought to be a key attribute for the promotion of iron absorption. Iron-chelatable protein hydrolysates are categorized by their absorption forms: amino acids, di- and tri-peptides and polypeptides. Their structural characteristics, including their size and amino acid sequence, as well as the presence of special amino acids, influence their iron chelation abilities and bioavailabilities. Protein hydrolysates promote iron absorption by keeping iron soluble, reducing ferric iron to ferrous iron, and promoting transport across cell membranes into the gut. We also discuss the use and relative merits of protein hydrolysates as iron supplements.

  3. Noble gas absorption process

    International Nuclear Information System (INIS)

    Thomas, J.W.

    1975-01-01

    A method of removing a noble gas from air comprising the use of activated carbon filters in stages in which absorption and desorption steps in succession are conducted in order to increase the capacity of the filters is described. (U.S.)

  4. UV absorption by cerium oxide nanoparticles/epoxy composite thin films

    International Nuclear Information System (INIS)

    Dao, Ngoc Nhiem; Luu, Minh Dai; Nguyen, Quang Khuyen; Kim, Byung Sun

    2011-01-01

    Cerium oxide (CeO 2 ) nanoparticles have been used to modify properties of an epoxy matrix in order to improve the ultra-violet (UV) absorption property of epoxy thin films. The interdependence of mechanical properties, UV absorption property and the dispersed concentration of CeO 2 nanoparticles was investigated. Results showed that, by increasing the dispersed concentration of CeO 2 nanoparticles up to 3 wt%, tensile modulus increases while two other mechanical properties, namely tensile strength and elongation, decrease. The UV absorption peak and the absorption edges of the studied thin films were observed in the UV-Vis absorption spectra. By incorporating CeO 2 nanoparticles into the epoxy matrix, an absorption peak appears at around 318 nm in UV-Vis spectra with increasing CeO 2 concentration from 0.1 to 1.0 wt%. Scanning electron microscopy (SEM) images revealed that a good dispersion of nanoparticles in the epoxy matrix by an ultrasonic method was achieved

  5. Synthesis, characterization and microwave absorption of carbon-coated Cu nanocapsules

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yuping [Center for Engineering Practice and Innovation Education, Anhui University of Technology, Maanshan, (China); Feng, Chao; Liu, Xianguo; Jin, Chuangui, E-mail: liuxianguohugh@gmail.com [School of Materials Science and Engineering, Anhui University of Technology, Maanshan (China); Or, Siu Wing [Department of Electrical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, (Hong Kong)

    2014-03-15

    The microstructure and microwave absorption of carbon-coated Cu nanocapsules have been investigated. Carbon-coated Cu nanocapsules have been synthesized by an arc-discharge method. The paraffin-Cu/C nanocapsules composite shows excellent electromagnetic (EM) absorption properties. An optimal reflection loss (RL) value of –40.0 dB is reached at 10.52 GHz for a layer 1.9 mm thickness. RL exceeding –20 dB can be realized in any interval within the 1-18 GHz range by choosing an appropriate thickness of the absorbent layer between 1.1 and 10.0 mm. Theoretical simulation for the microwave absorption using the transmission line theory agrees reasonably well with the experimental results. The EM-wave absorption properties of nanocapsules materials are illustrated by means of an absorption-tube-map. The carbon-coated Cu nano capsule is an attractive candidate for EM-wave absorption, which significantly enriches the family of EM-wave nano absorbents. (author)

  6. Standard Practice for Evaluating Solar Absorptive Materials for Thermal Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice covers a testing methodology for evaluating absorptive materials used in flat plate or concentrating collectors, with concentrating ratios not to exceed five, for solar thermal applications. This practice is not intended to be used for the evaluation of absorptive surfaces that are (1) used in direct contact with, or suspended in, a heat-transfer liquid, (that is, trickle collectors, direct absorption fluids, etc.); (2) used in evacuated collectors; or (3) used in collectors without cover plate(s). 1.2 Test methods included in this practice are property measurement tests and aging tests. Property measurement tests provide for the determination of various properties of absorptive materials, for example, absorptance, emittance, and appearance. Aging tests provide for exposure of absorptive materials to environments that may induce changes in the properties of test specimens. Measuring properties before and after an aging test provides a means of determining the effect of the exposure. 1.3 Th...

  7. Water absorption and mechanical properties of water-swellable natural rubber

    Directory of Open Access Journals (Sweden)

    Diew Saijun

    2009-11-01

    Full Text Available Water-swellable rubber (WSR was prepared by blending superabsorbent polymer (SAP of crosslinked poly(acrylamide-co-sodium acrylate with natural rubber in latex condition. The crosslinked poly(acrylamide-co-sodium acrylate was first prepared by inverse suspension polymerization from acrylamide and sodium acrylate monomers with potassiumpersulfate initiator and N,N-methylenebisacrylamide crosslinker. The reaction was carried out at 60oC for 40 mins. Water absorption properties, such as the degree of water absorption, water absorption rate, degree of weight loss, and mechanicalproperties of WSR were then investigated. It was found that the degree of water absorption, water absorption rate, and thedegree of weight loss increased, while tensile strength and elongation at break decreased with increasing quantity of SAP inthe blends. However, the degree of water absorption, degree of weight loss, and elongation at break decreased, but tensilestrength increased with increasing quantity of the N-tert-butyl-2-benzothiazyl sulphenamide (TBBS accelerator used in thecompounds formulation.

  8. Reliability of graphite furnace atomic absorption spectrometry as ...

    African Journals Online (AJOL)

    Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry (GFAAS) and hydride generation atomic absorption spectrometry (HGAAS) for trace analysis of arsenic (As) in natural herbal products (NHPs). Method: Arsenic analysis in natural herbal products and standard reference ...

  9. Thomson Thick X-Ray Absorption in a Broad Absorption Line Quasar, PG 0946+301.

    Science.gov (United States)

    Mathur; Green; Arav; Brotherton; Crenshaw; deKool; Elvis; Goodrich; Hamann; Hines; Kashyap; Korista; Peterson; Shields; Shlosman; van Breugel W; Voit

    2000-04-20

    We present a deep ASCA observation of a broad absorption line quasar (BALQSO) PG 0946+301. The source was clearly detected in one of the gas imaging spectrometers, but not in any other detector. If BALQSOs have intrinsic X-ray spectra similar to normal radio-quiet quasars, our observations imply that there is Thomson thick X-ray absorption (NH greater, similar1024 cm-2) toward PG 0946+301. This is the largest column density estimated so far toward a BALQSO. The absorber must be at least partially ionized and may be responsible for attenuation in the optical and UV. If the Thomson optical depth toward BALQSOs is close to 1, as inferred here, then spectroscopy in hard X-rays with large telescopes like XMM would be feasible.

  10. Effects of divalent amino acids on iron absorption

    International Nuclear Information System (INIS)

    Christensen, J.M.; Ghannam, M.; Ayres, J.W.

    1984-01-01

    Solutions of each of 10 amino acids or ascorbic acid were mixed with iron and orally administered to rats. Iron was absorbed to a statistically significantly greater extent when mixed with asparagine, glycine, serine, or ascorbic acid as compared with a control solution of iron. The largest effects were for asparagine and glycine, which also increased iron absorption to a significantly greater extent than did serine or ascorbic acid. No statistically significant increase in iron absorption occurred when any of the other amino acids was mixed with iron. The extent of iron absorption from each test solution, as measured by area under the concentration of iron-59 in the blood-time curve (r2 . 0.0002), and the initial rate of iron absorption for each test solution (r2 . 0.01) showed no correlation with the stability constant of the amino acid-iron complex

  11. Absorption spectra of trapped holes in anatase TiO2

    DEFF Research Database (Denmark)

    Zawadzki, Pawel

    2013-01-01

    absorption spectroscopy (TAS), but the understanding of the optical absorption due to trapped carriers in TiO2 is incomplete. On the basis of the generalized Δ self-consistent field density functional theory (Δ-SCF DFT) calculations, we attribute the experimentally observed absorption band at 430-550 nm...

  12. The effects of three absorption-modifying critical excipients on the in vivo intestinal absorption of six model compounds in rats and dogs.

    Science.gov (United States)

    David, Dahlgren; Carl, Roos; Pernilla, Johansson; Christer, Tannergren; Anders, Lundqvist; Peter, Langguth; Markus, Sjöblom; Erik, Sjögren; Hans, Lennernäs

    2018-05-11

    Pharmaceutical excipients that may affect gastrointestinal (GI) drug absorption are called critical pharmaceutical excipients (CPEs), or absorption-modifying excipients (AMEs) if they act by altering the integrity of the intestinal epithelial cell membrane. Some of these excipients increase intestinal permeability, and subsequently the absorption and bioavailability of the drug. This could have implications for both the assessment of bioequivalence and the efficacy of the absorption-enhancing drug delivery system. The absorption-enhancing effects of AMEs/CPEs with different mechanisms (chitosan, sodium caprate, sodium dodecyl sulfate (SDS)) have previously been evaluated in the rat single-pass intestinal perfusion (SPIP) model. However, it remains unclear whether these SPIP data are predictive in a more in vivo like model. The same excipients were in this study evaluated in rat and dog intraintestinal bolus models. SDS and chitosan did exert an absorption-enhancing effect in both bolus models, but the effect was substantially lower than those observed in the rat SPIP model. This illustrates the complexity of the AME/CPE effects, and indicates that additional GI physiological factors need to be considered in their evaluation. We therefore recommend that AME/CPE evaluations obtained in transit-independent, preclinical permeability models (e.g. Ussing, SPIP) should be verified in animal models better able to predict in vivo relevant GI effects, at multiple excipient concentrations. Copyright © 2018. Published by Elsevier B.V.

  13. Linking Transformational Leadership, Absorptive Capacity, and Corporate Entrepreneurship

    Directory of Open Access Journals (Sweden)

    Imran Shafique

    2018-03-01

    Full Text Available This study aims to analyze the nexus between transformational leadership and corporate entrepreneurship through an integration of dispersed scholarly work on transformational leadership, absorptive capacity, and corporate entrepreneurship under one framework. A survey method was employed for the collection of data from small and medium-sized enterprises (SMEs of Pakistan. The data were analyzed using structural equation modeling (SEM technique to empirically test the hypotheses. The results demonstrate that transformational leadership positively affects corporate entrepreneurship and its dimensions—namely, innovation, new business venturing, self-renewal, proactivity, and risk-taking—both directly and through absorptive capacity. The potential of transformational leadership to influence corporate entrepreneurship via absorptive capacity added additional interesting substitutes. Future studies may produce novel insights by examining different leadership styles, settings, or utilizing qualitative technique. Firms should invest to initiate transformational leadership training programs for their managers. Additionally, if these firms are aiming to promote corporate entrepreneurship, they should focus on hiring managers that have attributes of transformational leadership. Furthermore, they should also invest in absorptive capacity to utilize outside knowledge for the enhancement of entrepreneurial activities. This study exploits research work on the relationship between transformational leadership and corporate entrepreneurship in a novel way; it investigates the dimensions of entrepreneurship individually, as well as unidimensionally, and includes the mediating role of absorptive capacity and tests several other hypotheses that previously have been ignored. This study, compared to the existing research, contributes to the impact of transformational leadership on corporate entrepreneurship and absorptive capacity, especially in Pakistan

  14. An Empirical Investigation into a Subsidiary Absorptive Capacity Process Model

    DEFF Research Database (Denmark)

    Schleimer, Stephanie; Pedersen, Torben

    2011-01-01

    and empirically test a process model of absorptive capacity. The setting of our empirical study is 213 subsidiaries of multinational enterprises and the focus is on the capacity of these subsidiaries to successfully absorb best practices in marketing strategy from their headquarters. This setting allows us...... to explore the process model in its entirety, including different drivers of subsidiary absorptive capacity (organizational mechanisms and contextual drivers), the three original dimensions of absorptive capacity (recognition, assimilation, application), and related outcomes (implementation...... and internalization of the best practice). The study’s findings reveal that managers have discretion in promoting absorptive capacity through the application of specific organizational mechanism and that the impact of contextual drivers on subsidiary absorptive capacity is not direct, but mediated...

  15. Optical absorptions in ZnO/a-Si distributed Bragg reflectors

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Aqing, E-mail: aqchen@hdu.edu.cn; Chen, Zhian [Hangzhou Dianzi University, College of Materials & Environmental Engineering (China); Zhu, Kaigui [Beihang University, Department of physics (China); Ji, Zhenguo [Hangzhou Dianzi University, College of Materials & Environmental Engineering (China)

    2017-01-15

    The distributed Bragg reflectors (DBRs) consisting of alternating layers of ZnO and heavy doped amorphous silicon (a-Si) have been fabricated by magnetron sputtering. It is novel to find that the optical absorptions exist in the stopband of the DBRs, and that many discrete strong optical absorption peaks exist in the wavelength range of visible to near-infrared. The calculated results by FDTD show that the absorptions in the stopband mainly exist in the first a-Si layer, and that the light absorbed by other a-Si layers inside contributes to the two absorption peaks in near-infrared range. The strong absorptions ranged from visible to infrared open new possibilities to the enhancement of the performance of amorphous silicon solar cells.

  16. [INVITED] Coherent perfect absorption of electromagnetic wave in subwavelength structures

    Science.gov (United States)

    Yan, Chao; Pu, Mingbo; Luo, Jun; Huang, Yijia; Li, Xiong; Ma, Xiaoliang; Luo, Xiangang

    2018-05-01

    Electromagnetic (EM) absorption is a common process by which the EM energy is transformed into other kinds of energy in the absorber, for example heat. Perfect absorption of EM with structures at subwavelength scale is important for many practical applications, such as stealth technology, thermal control and sensing. Coherent perfect absorption arises from the interplay of interference and absorption, which can be interpreted as a time-reversed process of lasing or EM emitting. It provides a promising way for complete absorption in both nanophotonics and electromagnetics. In this review, we discuss basic principles and properties of a coherent perfect absorber (CPA). Various subwavelength structures including thin films, metamaterials and waveguide-based structures to realize CPAs are compared. We also discuss the potential applications of CPAs.

  17. Absorption from multicomponent gas mixtures comparing with Elemir gasoline plant

    Energy Technology Data Exchange (ETDEWEB)

    Miscevic, D

    1970-10-01

    A short description and explanation are outlined of all factors which have influence on hydrocarbon absorption from multicomponent gas mixtures. A short review of these different methods for absorption efficiency calculation is given. On the basis of the explained methods, the absorption from one natural gas at the Elemir plant is calculated and the results are given in tabular data. The number of the theoretical plate and L/V ratio for a given recovery of the key component is fixed by the calculation and by a graphical solution. Special attention is given for absorption oil depending on gas flow, pressure, and temperature. A series of diagrams is presented showing required absorption oil at the Elemir plant for given propane recovery, depending on the variables which are mentioned.

  18. Fluoride absorption: independence from plasma fluoride levels

    International Nuclear Information System (INIS)

    Whitford, G.M.; Williams, J.L.

    1986-01-01

    The concept that there are physiologic mechanisms to homeostatically regulate plasma fluoride concentrations has been supported by results in the literature suggesting an inverse relationship between plasma fluoride levels and the absorption of the ion from the gastrointestinal tract of the rat. The validity of the relationship was questioned because of possible problems in the experimental design. The present work used four different methods to evaluate the effect of plasma fluoride levels on the absorption of the ion in rats: (i) the percentage of the daily fluoride intake that was excreted in the urine; (ii) the concentration of fluoride in femur epiphyses; (iii) the net areas under the time-plasma fluoride concentration curves after intragastric fluoride doses; and (iv) the residual amounts or fluoride in the gastrointestinal tracts after the intragastric fluoride doses. None of these methods indicated that plasma fluoride levels influence the rate or the degree or fluoride absorption. It was concluded that, unless extremely high plasma fluoride levels are involved (pharmacologic or toxic doses), the absorption of the ion is independent of plasma levels. The results provide further evidence that plasma fluoride concentrations are not homeostatically regulated

  19. The Role of Absorption Cooling for Reaching Sustainable Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lindmark, Susanne

    2005-07-01

    This thesis focuses on the role and potential of absorption cooling in future energy systems. Two types of energy systems are investigated: a district energy system based on waste incineration and a distributed energy system with natural gas as fuel. In both cases, low temperature waste heat is used as driving energy for the absorption cooling. The main focus is to evaluate the absorption technology in an environmental perspective, in terms of reduced CO{sub 2} emissions. Economic evaluations are also performed. The reduced electricity when using absorption cooling instead of compression cooling is quantified and expressed as an increased net electrical yield. The results show that absorption cooling is an environmentally friendly way to produce cooling as it reduces the use of electrically driven cooling in the energy system and therefore also reduces global CO{sub 2} emissions. In the small-scale trigeneration system the electricity use is lowered with 84 % as compared to cooling production with compression chillers only. The CO{sub 2} emissions can be lowered to 45 CO{sub 2}/MWh{sub c} by using recoverable waste heat as driving heat for absorption chillers. However, the most cost effective cooling solution in a district energy system is a combination between absorption and compression cooling technologies according to the study. Absorption chillers have the potential to be suitable bottoming cycles for power production in distributed systems. Net electrical yields over 55 % may be reached in some cases with gas motors and absorption chillers. This small-scale system for cogeneration of power and cooling shows electrical efficiencies comparable to large-scale power plants and may contribute to reducing peak electricity demand associated with the cooling demand.

  20. Interference-free mid-IR laser absorption detection of methane

    International Nuclear Information System (INIS)

    Pyun, Sung Hyun; Cho, Jungwan; Davidson, David F; Hanson, Ronald K

    2011-01-01

    A novel, mid-IR scanned-wavelength laser absorption diagnostic was developed for time-resolved, interference-free, absorption measurement of methane concentration. A differential absorption (peak minus valley) scheme was used that takes advantage of the structural differences of the absorption spectrum of methane and other hydrocarbons. A peak and valley wavelength pair was selected to maximize the differential cross-section (σ peak minus valley ) of methane for the maximum signal-to-noise ratio, and to minimize that of the interfering absorbers. Methane cross-sections at the peak and valley wavelengths were measured over a range of temperatures, 1000 to 2000 K, and pressures 1.3 to 5.4 atm. The cross-sections of the interfering absorbers were assumed constant over the small wavelength interval between the methane peak and valley features. Using this diagnostic, methane concentration time histories during n-heptane pyrolysis were measured behind reflected shock waves in a shock tube. The differential absorption scheme efficiently rejected the absorption interference and successfully recovered the vapor-phase methane concentration. These measurements allowed the comparison with methane concentration time-history simulations derived from a current n-heptane reaction mechanism (Sirjean et al 2009 A high-temperature chemical kinetic model of n-alkane oxidation JetSurF version 1.0)

  1. Molecular Dynamics Investigation of Efficient SO₂ Absorption by ...

    Indian Academy of Sciences (India)

    Ionic liquids are appropriate candidates for the absorption of acid gases such as SO₂. Six anion functionalized ionic liquids with different basicities have been studied for SO₂ absorption capacity by employing quantum chemical calculations and molecular dynamics (MD) simulations. Gas phase quantum calculations ...

  2. Self-absorption corrections for well-type germanium detectors

    International Nuclear Information System (INIS)

    Appleby, P.G.; Richardson, N.; Nolan, P.J.

    1992-01-01

    Corrections for self-absorption are of vital importance to accurate determination by gamma spectrometry of radionuclides such as 210 Pb, 241 Am and 234 Th which emit low energy gamma radiation. A simple theoretical model for determining the necessary corrections for well-type germanium detectors is presented. In this model, self-absorption factors are expressed in terms of the mass attenuation coefficient of the sample and a parameter characterising the well geometry. Experimental measurements of self-absorption are used to evaluate the model and to determine a semi-empirical algorithm for improved estimates of the geometrical parameter. (orig.)

  3. Wet bar detection by using water absorption detector

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Bae, Yong Chae; Kee, Chang Doo

    2008-01-01

    Water leaks in water-cooled generator stator windings can generate serious accidents such as insulation breakdown and result in unexpected sudden outages. Thus, it is important to diagnose their water absorption for effective operation of the power plant. Especially, since the capacitance values that are measured for diagnosis are very small so special diagnosis methods like stochastic theory are needed. KEPRI developed a more advanced water absorption detector and diagnosis technology for it. They were applied to a real system and the results of the water absorption test for stator windings agree with the water leak test

  4. Hydrolysis Batteries: Generating Electrical Energy during Hydrogen Absorption.

    Science.gov (United States)

    Xiao, Rui; Chen, Jun; Fu, Kai; Zheng, Xinyao; Wang, Teng; Zheng, Jie; Li, Xingguo

    2018-02-19

    The hydrolysis reaction of aluminum can be decoupled into a battery by pairing an Al foil with a Pd-capped yttrium dihydride (YH 2 -Pd) electrode. This hydrolysis battery generates a voltage around 0.45 V and leads to hydrogen absorption into the YH 2 layer. This represents a new hydrogen absorption mechanism featuring electrical energy generation during hydrogen absorption. The hydrolysis battery converts 8-15 % of the thermal energy of the hydrolysis reaction into usable electrical energy, leading to much higher energy efficiency compared to that of direct hydrolysis. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Systemic Absorption of Nanomaterials by Oral Exposure

    DEFF Research Database (Denmark)

    Binderup, Mona-Lise; Bredsdorff, Lea; Beltoft, Vibe Meister

    This report and accompanying database systematically evaluates the reliability and relevance of the existing scientific literature regarding systemic absorption of nanomaterials by oral exposure and makes specific recommendations for future testing approaches.......This report and accompanying database systematically evaluates the reliability and relevance of the existing scientific literature regarding systemic absorption of nanomaterials by oral exposure and makes specific recommendations for future testing approaches....

  6. Nonlinear cyclotron absorption and stimulated scattering

    International Nuclear Information System (INIS)

    Chung, T.H.

    1986-01-01

    In electron cyclotron resonance heating (ECRH), wave sources heating a plasma linearly with respect to intensity; but as the intensity of ECRH gets larger, there might appear nonlinear effects that would result in cutoff of net absorption. This thesis uses quantum mechanical theory to derive a threshold microwave intensity for nonlinear absorption. The quantum mechanical theory estimates that the threshold microwave intensity for nonlinear absorption is about 10 5 watts/cm 2 for a microwave heating experiment (T/sub e/ = 100 ev, λ = 3,783 cm, B = 2.5 kG). This value seems large considering the present power capabilities of microwave sources (10 2 ∼ 10 3 watts/cm 2 ), but for a low temperature plasma, this threshold will go down. There is another nonlinear phenomenon called stimulated cyclotron scattering that enhances photon scattering by electrons gyrating in a magnetic field. This is expected to prevent incoming photons from arriving at the central region of the fusion plasma, where absorption mainly takes place. Theory based on a photon transport model predicts that the threshold intensity for the stimulated cyclotron scattering is about 10 4 watts/cm 2 for the plasma parameters mentioned above. This value seems large also, but a longer wavelength of microwaves and a larger magnitude magnetic field, which will be the case in reactor type facilities, will lower the threshold intensity to levels comparable with the currently developed microwave sources

  7. Chloride absorption by root, leaf and floral tissues of Petunia

    International Nuclear Information System (INIS)

    Jooste, J.H.

    1980-01-01

    Chloride absorption by root, leaf and floral tissues of Petunia was compared at two temperatures (30 and 2 degrees Celcius), employing different absorption periods, and in the presence and absence of a desorption treatment. All treatments revealed highest absorption by floral tissue. This was further confirmed by the absorption of chloride by the various tissues from solutions in the low (0-1 mM) and high (1-50 mM) concentration ranges. The results offer a possible explanation for the observed effects of organic and inorganic solutes on the longevity of cut flowers [af

  8. Organizational forms and knowledge absorption

    Directory of Open Access Journals (Sweden)

    Radovanović Nikola

    2016-01-01

    Full Text Available Managing the entire portion of knowledge in an organization is a challenging task. At the organizational level, there can be enormous quantities of unknown, poorly valued or inefficiently applied knowledge. This is normally followed with the underdeveloped potential or inability of organizations to absorb knowledge from external sources. Facilitation of the efficient internal flow of knowledge within the established communication network may positively affect organizational capacity to absorb or identify, share and subsequently apply knowledge to commercial ends. Based on the evidences that the adoption of different organizational forms affects knowledge flows within an organization, this research analyzed the relationship between common organizational forms and absorptive capacity of organizations. In this paper, we test the hypothesis stating that the organizational structure affects knowledge absorption and exploitation in the organization. The methodology included quantitative and qualitative research method based on a questionnaire, while the data has been statistically analyzed and the hypothesis has been tested with the use of cross-tabulation and chi-square tests. The findings suggest that the type of organizational form affects knowledge absorption capacity and that having a less formalized and more flexible structure in an organization increases absorbing and exploiting opportunities of potentially valuable knowledge.

  9. Derivative flame atomic absorption spectrometry and its application in trace analysis

    International Nuclear Information System (INIS)

    Sun, H. W.; Li, L. Q.

    2005-01-01

    Flame atomic absorption spectrometry is an accepted and widely used method for the determination of trace elements in a great variety of samples. But its sensitivity doesn't meet the demands of trace and ultra-trace analysis for some samples. The derivative signal processing technique, with a very high capability for enhancing sensitivity, was developed for flame atomic absorption spectrometry. The signal models of conventional flame atomic absorption spectrometry are described. The equations of derivative signals are established for flame atomic absorption spectrometry, flow injection atomic absorption spectrometry (FI-FAAS) and atom trapping flame atomic absorption spectrometry (AT-FAAS). The principle and performance of the derivative atomic absorption spectrometry are evaluated. The derivative technique based on determination of variation rate of signal intensity with time (dl/dt) is different from the derivative spectrophotometry based on determination of variation rate of signal intensity with wavelength (dl/dhλ). Derivative flame atomic absorption spectrometry has higher sensitivity, lower detection limits and better accuracy. It has been applied to the direct determination of trace elements without preconcentration. If the derivative technique was combined with several preconcentration techniques, the sensitivity would be enhanced further for ultra-trace analysis with good linearity. The applications of derivative flame atomic absorption spectroscopy are reviewed for trace element analysis in biological, pharmaceutical, environmental and food samples

  10. Identification of MgII Absorption Line Systems from SDSS Quasar ...

    Indian Academy of Sciences (India)

    Motivation. The quasar absorption lines are crucial to our understanding of the Universe since the absorption lines provide a wealth of information on the gaseous Universe from high redshift to present day. The absorption lines can also allow us to probe the metallicity and ionization state of the gas (Wild et al. 2008).

  11. Scramjet Performance Assessment Using Water Absorption Diagnostics (U)

    Science.gov (United States)

    Cavolowsky, John A.; Loomis, Mark P.; Deiwert, George

    1995-01-01

    Simultaneous multiple path measurements of temperature and H2O concentration will be presented for the AIMHYE test entries in the NASA Ames 16-Inch Shock Tunnel. Monitoring the progress of high temperature chemical reactions that define scramjet combustor efficiencies is a task uniquely suited to nonintrusive optical diagnostics. One application strategy to overcome the many challenges and limitations of nonintrusive measurements is to use laser absorption spectroscopy coupled with optical fibers. Absorption spectroscopic techniques with rapidly tunable lasers are capable of making simultaneous measurements of mole fraction, temperature, pressure, and velocity. The scramjet water absorption diagnostic was used to measure combustor efficiency and was compared to thrust measurements using a nozzle force balance and integrated nozzle pressures to develop a direct technique for evaluating integrated scramjet performance. Tests were initially performed with a diode laser tuning over a water absorption feature at 1391.7 nm. A second diode laser later became available at a wavelength near 1343.3 nm covering an additional water absorption feature and was incorporated in the system for a two-wavelength technique. Both temperature and mole fraction can be inferred from the lineshape analysis using this approach. Additional high temperature spectroscopy research was conducted to reduce uncertainties in the scramjet application. The lasers are optical fiber coupled to ports at the combustor exit and in the nozzle region. The output from the two diode lasers were combined in a single fiber, and the resultant two-wavelength beam was subsequently split into four legs. Each leg was directed through 60 meters of optical fiber to four combustor exit locations for measurement of beam intensity after absorption by the water within the flow. Absorption results will be compared to 1D combustor analysis using RJPA and nozzle CFD computations as well as to data from a nozzle metric

  12. Subcutaneous insulin absorption explained by insulin's physicochemical properties. Evidence from absorption studies of soluble human insulin and insulin analogues in humans.

    Science.gov (United States)

    Kang, S; Brange, J; Burch, A; Vølund, A; Owens, D R

    1991-11-01

    To study the influence of molecular aggregation on rates of subcutaneous insulin absorption and to attempt to elucidate the mechanism of absorption of conventional soluble human insulin in humans. Seven healthy male volunteers aged 22-43 yr and not receiving any drugs comprised the study. This study consisted of a single-blind randomized comparison of equimolar dosages of 125I-labeled forms of soluble hexameric 2 Zn2+ human insulin and human insulin analogues with differing association states at pharmaceutical concentrations (AspB10, dimeric; AspB28, mixture of monomers and dimers; AspB9, GluB27, monomeric). After an overnight fast and a basal period of 1 h, 0.6 nmol/kg of either 125I-labeled human soluble insulin (Actrapid HM U-100) or 125I-labeled analogue was injected subcutaneously on 4 separate days 1 wk apart. Absorption was assessed by measurement of residual radioactivity at the injection site by external gamma-counting. The mean +/- SE initial fractional disappearance rates for the four preparations were 20.7 +/- 1.9 (hexameric soluble human insulin), 44.4 +/- 2.5 (dimeric analogue AspB10), 50.6 +/- 3.9 (analogue AspB28), and 67.4 +/- 7.4%/h (monomeric analogue AspB9, GluB27). Absorption of the dimeric analogue was significantly faster than that of hexameric human insulin (P less than 0.001); absorption of monomeric insulin analogue AspB9, GluB27 was significantly faster than that of dimeric analogue AspB10 (P less than 0.01). There was an inverse linear correlation between association state and the initial fractional disappearance rates (r = -0.98, P less than 0.02). Analysis of the disappearance data on a log linear scale showed that only the monomeric analogue had a monoexponential course throughout. Two phases in the rates of absorption were identified for the dimer and three for hexameric human insulin. The fractional disappearance rates (%/h) calculated by log linear regression analysis were monomer 73.3 +/- 6.8; dimer 44.4 +/- 2.5 from 0 to 2 h and

  13. Sound absorption and morphology characteristic of porous concrete paving blocks

    Science.gov (United States)

    Halim, N. H. Abd; Nor, H. Md; Ramadhansyah, P. J.; Mohamed, A.; Hassan, N. Abdul; Ibrahim, M. H. Wan; Ramli, N. I.; Nazri, F. Mohamed

    2017-11-01

    In this study, sound absorption and morphology characteristic of Porous Concrete Paving Blocks (PCPB) at different sizes of coarse aggregate were presented. Three different sizes of coarse aggregate were used; passing 10 mm retained 5 mm (as Control), passing 8 mm retained 5 mm (8 - 5) and passing 10 mm retained 8 mm (10 - 8). The sound absorption test was conducted through the impedance tube at different frequency. It was found that the size of coarse aggregate affects the level of absorption of the specimens. It also shows that PCPB 10 - 8 resulted in high sound absorption compared to the other blocks. On the other hand, microstructure morphology of PCPB shows a clearer version of existing micro-cracks and voids inside the specimens which affecting the results of sound absorption.

  14. The CO_2 absorption spectrum in the 2.3 µm transparency window by high sensitivity CRDS: (II) Self-absorption continuum

    International Nuclear Information System (INIS)

    Mondelain, D.; Vasilchenko, S.; Čermák, P.; Kassi, S.; Campargue, A.

    2017-01-01

    The CO_2 absorption continuum near 2.3 µm is determined for a series of sub atmospheric pressures (250–750 Torr) by high sensitivity Cavity Ring Down Spectroscopy. An experimental procedure consisting in injecting successively a gas flow of CO_2 and synthetic air, keeping constant the gas pressure in the CRDS cell, has been developed. This procedure insures a high stability of the spectra baseline by avoiding changes of the optical alignment due to pressure changes. The CO_2 continuum was obtained as the difference between the CO_2 absorption coefficient and a local lines simulation using a Voigt profile truncated at ±25 cm"−"1. Following the results of the preceding analysis of the CO_2 rovibrational lines (Vasilchenko S et al. J Quant Spectrosc Radiat Transfer (10.1016/j.jqsrt.2016.07.002), a CO_2 line list with intensities obtained by variational calculations and empirical line positions was preferred to the HITRAN line list. A quadratic pressure dependence of the absorption continuum is observed, with an average binary absorption coefficient increasing from 2 to 4×10"−"8 cm"−"1 amagat"−"2 between 4320 and 4380 cm"−"1. The obtained continuum is found in good agreement with a previous measurement using much higher densities (20 amagat) and a low resolution grating spectrograph and is consistent with values currently used in the analysis of Venus spectra. - Highlights: • The CO_2 absorption continuum is measured by CRDS in the 2.3 µm window. • The achieved sensitivity and stability allow measurements at sub-atmospheric pressure. • The absorption coefficient is on the order of 3×10"−"8 cm"−"1 amagat"−"2 near 4350 cm"−"1. • A good agreement is obtained with previous results at much higher density (20 amagat).

  15. The TApIR experiment. IR absorption spectra of liquid hydrogen isotopologues

    International Nuclear Information System (INIS)

    Groessle, Robin

    2015-01-01

    The scope of the thesis is the infrared absorption spectroscopy of liquid hydrogen isotopologues with the tritium absorption infrared spectroscopy (TApIR) experiment at the tritium laboratory Karlsruhe (TLK). The calibration process from the sample preparation to the reference measurements are described. A further issue is the classical evaluation of FTIR absorption spectra and the extension using the rolling circle filter (RCF) including the effects on statistical and systematical errors. The impact of thermal and nuclear spin temperature on the IR absorption spectra is discussed. An empirical based modeling for the IR absorption spectra of liquid hydrogen isotopologues is performed.

  16. Temperature Dependences of Mechanisms Responsible for the Water-Vapor Continuum Absorption

    Science.gov (United States)

    Ma, Qiancheng

    2014-01-01

    The water-vapor continuum absorption plays an important role in the radiative balance in the Earth's atmosphere. It has been experimentally shown that for ambient atmospheric conditions, the continuum absorption scales quadratically with the H2O number density and has a strong, negative temperature dependence (T dependence). Over the years, there have been three different theoretical mechanisms postulated: far-wings of allowed transition lines, water dimers, and collision-induced absorption. The first mechanism proposed was the accumulation of absorptions from the far-wings of the strong allowed transition lines. Later, absorption by water dimers was proposed, and this mechanism provides a qualitative explanation for the continuum characters mentioned above. Despite the improvements in experimental data, at present there is no consensus on which mechanism is primarily responsible for the continuum absorption.

  17. Enhanced index and negative dispersion without absorption in driven cascade media

    International Nuclear Information System (INIS)

    Hu Xiangming; Xu Jun

    2004-01-01

    In this paper we investigate the dispersive and absorptive properties of a system of three-level cascade atoms driven by a strong coherent field. Three characteristic features are found. First, for the same set of atom-light interaction parameters, the indices of refraction are large at three different frequencies where the absorption vanishes. These three frequencies are determined by the resonance transition frequencies between dressed states produced by the strong driving field. Second, negative dispersion without absorption, which leads to superluminal light propagation, is achievable in the central resonance structure of the dispersion spectrum. Third, the whole absorption spectrum displays, in general, three pairs of absorption peaks and three pairs of gain (negative absorption) peaks. The minimal spacing between dressed states determines whether the outer adjacent gain peaks are separated from each other

  18. Single-shot measurement of nonlinear absorption and nonlinear refraction.

    Science.gov (United States)

    Jayabalan, J; Singh, Asha; Oak, Shrikant M

    2006-06-01

    A single-shot method for measurement of nonlinear optical absorption and refraction is described and analyzed. A spatial intensity variation of an elliptical Gaussian beam in conjugation with an array detector is the key element of this method. The advantages of this single-shot technique were demonstrated by measuring the two-photon absorption and free-carrier absorption in GaAs as well as the nonlinear refractive index of CS2 using a modified optical Kerr setup.

  19. Sound absorption of low-temperature reusable surface insulation candidate materials

    Science.gov (United States)

    Johnston, J. D.

    1974-01-01

    Sound absorption data from tests of four candidate low-temperature reusable surface insulation materials are presented. Limitations on the use of the data are discussed, conclusions concerning the effective absorption of the materials are drawn, and the relative significance to Vibration and Acoustic Test Facility test planning of the absorption of each material is assessed.

  20. Attenuation studies near K-absorption edges using Compton ...

    Indian Academy of Sciences (India)

    The results are consistent with theoretical values derived from the XCOM package. Keywords. Photon interaction; 241Am; gamma ray attenuation; Compton scattering; absorption edge; rare earth elements. PACS Nos 32.80.-t; 32.90.+a. 1. Introduction. Photon interaction studies at energies around the absorption edge have ...

  1. Deuterium absorption property of Al/Zr-V/Mo multifilms

    International Nuclear Information System (INIS)

    Wang Haifeng; Peng Shuming; Zhang Xiaohong; Long Xinggui; Yang Benfu

    2005-01-01

    Deuterium absorption property of Al/Zr-V/Mo multifilms was studied experimentally to explore the effect of Al film. There is only one desorption peak at 320 degree C for Al film, two desorption peaks at 220 degree C and 350 degree C for Zr-V film. When the average thickness of Al film is less than 0.6 μm, the desorption property of Al/Zr-V multifilms is just as Zr-V film, when it is more than 0.6 μm, just as Al film. Deuterium absorption by Al/Zr-V multifilms decreases as the thickness of Al film increases until 0.7 μm, then the deuterium absorption no longer changes significantly. The Al film of multifilms cracks on desorbing, so the absorption rate varies as Zr-V film when the thickness of Al film is less than 0.6 μ. When the thickness of Al film is more than 0.6 μm, the deuterium absorption rate of multifilm does not change with the thickness of Al film. (author)

  2. Resonant absorption of electromagnetic waves in transition anisotropic media.

    Science.gov (United States)

    Kim, Kihong

    2017-11-27

    We study the mode conversion and resonant absorption phenomena occurring in a slab of a stratified anisotropic medium, optical axes of which are tilted with respect to the direction of inhomogeneity, using the invariant imbedding theory of wave propagation. When the tilt angle is zero, mode conversion occurs if the longitudinal component of the permittivity tensor, which is the one in the direction of inhomogeneity in the non-tilted case, varies from positive to negative values within the medium, while the transverse component plays no role. When the tilt angle is nonzero, the wave transmission and absorption show an asymmetry under the sign change of the incident angle in a range of the tilt angle, while the reflection is always symmetric. We calculate the reflectance, the transmittance and the absorptance for several configurations of the permittivity tensor and find that resonant absorption is greatly enhanced when the medium from the incident surface to the resonance region is hyperbolic than when it is elliptic. For certain configurations, the transmittance and absorptance curves display sharp peaks at some incident angles determined by the tilt angle.

  3. Infrared-laser spectroscopy using a long-pathlength absorption cell

    International Nuclear Information System (INIS)

    Kim, K.C.; Briesmeister, R.A.

    1983-01-01

    The absorption measurements in an ordinary cell may require typically a few torr pressure of sample gas. At these pressures the absorption lines are usually pressure-broadened and, therefore, closely spaced transitions are poorly resolved even at diode-laser resolution. This situation is greatly improved in Doppler-limited spectroscopy at extremely low sample pressures. Two very long-pathlength absorption cells were developed to be used in conjunction with diode lasers. They were designed to operate at controlled temperatures with the optical pathlength variable up to approx. 1.5 km. Not only very low sample pressures are used for studies with such cells but also the spectroscopic sensitivity is enhanced over conventional methods by a factor of 10 3 to 10 4 , improving the analytical capability of measuring particle densities to the order of 1 x 10'' molecules/cm 3 . This paper presents some analytical aspects of the diode laser spectroscopy using the long-pathlength absorption cells in the areas of absorption line widths, pressure broadening coefficients, isotope composition measurements and trace impurity analysis

  4. Red gold analysis by using gamma absorption tchnique

    International Nuclear Information System (INIS)

    Kurtoglu, A.; Tugrul, A.B.

    2001-01-01

    Gold is a valuable metal and also preferable materials for antique artefacts and some advanced technology products. It can be offered for the analysis of the gold as namely; neutron activation analysis, X-ray florescence technique, Auger spectroscopy, atomic absorption and wet chemistry. Some limitations exist in practice for these techniques, especially in the points of financial and applicability concepts. An advanced a practical technique is gamma absorption technique for the gold alloys. This technique is based on discontinuities in the absorption coefficient for gamma rays at corresponding to the electronic binding energies of the absorber. If irradiation is occurred at gamma absorption energy for gold, absorption rates of the red gold changes via the gold amounts in the alloy. Red gold is a basic and generally preferable alloy that has copper and silver additional of the gold in it. The gold amount defines as carat of the gold. Experimental studies were observed for four different carats of red gold; these are 8, 14, 18 and 22 carats. K-edge energy level of the gold is on 80 keV energy. So, Ba-133 radioisotope is preferred as the gamma source because of it has gamma energy peak in that energy. Experiments observed in the same geometry for all samples. NaI(Tl) detector and multichannel analyser were used for measurements. As a result of the experiments, the calibration curves could be drawn for red gold. For examine this curve, unknown samples are measured in experimental set and it can be determined the carat of it with the acceptability. So the red gold analysis can be observed non-destructively, easily and quickly by using the gamma absorption technique

  5. THz induced nonlinear absorption in ZnTe

    DEFF Research Database (Denmark)

    Pedersen, Pernille Klarskov; Jepsen, Peter Uhd

    2015-01-01

    Absorption spectra of ZnTe during strong-field THz interaction are investigated. Bleaching of the difference phonon modes below the fundamental TO mode is observed when field strengths higher than 4 MV/cm are applied.......Absorption spectra of ZnTe during strong-field THz interaction are investigated. Bleaching of the difference phonon modes below the fundamental TO mode is observed when field strengths higher than 4 MV/cm are applied....

  6. Concentration-modulated absorption spectroscopy and the triplet state: Photoinduced absorption/bleaching in erythrosin B, rose bengal and eosin y

    Science.gov (United States)

    Jones, W. Jeremy; Grofcsik, Andras; Kubinyi, Miklos; Thomas, Daniel

    2006-07-01

    The pump and probe method concentration-modulated absorption spectroscopy has been applied for studying the triplet characteristics of dyes erythrosin B, rose bengal and eosin y in ethanol solutions. Using the 514.5 and 488 nm lines of an argon ion laser for pump and probe beams, respectively, photoinduced bleaching for erythrosin B and eosin y and photoinduced absorption for rose bengal have been observed. The theory developed for describing the interactions of dye molecules of strong triplet forming ability with continuous wave pump and probe beams of Gaussian beam profiles has been tested by analysing the probe power gain or loss at different positions along the optical path of the focused collinear beams. From the gain-modulation frequency curves triplet absorption cross sections and the lifetimes of the triplet states have been determined.

  7. Transient absorption studies in pure rare gases from 2500 A to 4000 A

    Energy Technology Data Exchange (ETDEWEB)

    Champagne, L F; Chang, R S.F. [Naval Research Lab., Washington, DC (USA)

    1980-01-01

    The broad band absorption in electron beam excited rare gas plasmas was measured for neon, argon, krypton and xenon gas. A broad continuum emission from a xenon flashlamp was used as the probe source. Absorption data was obtained over a 1500 A range. Absorption peaks in argon, neon and xenon correlate well with the predicted peak absorption cross sections for the respective dimer ions. No absorption peak in krypton was observed. Secondary absorption peaks of comparable magnitude to the dimer absorption peak were also observed in argon and xenon.

  8. Optical absorption and energy transfer processes in dendrimers

    International Nuclear Information System (INIS)

    Reineker, P.; Engelmann, A.; Yudson, V.I.

    2004-01-01

    For dendrimers of various sizes the energy transfer and the optical absorption is investigated theoretically. The molecular subunits of a dendrimer are modeled as two-level systems. The electronic interaction between them is described via transfer integrals and the influence of vibrational degrees of freedom is taken into account in a first approach using a stochastic model. We discuss the time dependence of the energy transport and show that rim states of the dendrimer dominate the absorption spectra, that in general the electronic excitation energy is concentrated on peripheric molecules, and that the energetically lowest absorption peak is redshifted with increasing dendrimer size due to delocalization of the electronic excitation

  9. Probing molecular chirality by coherent optical absorption spectra

    Energy Technology Data Exchange (ETDEWEB)

    Jia, W. Z. [Quantum Optoelectronics Laboratory, School of Physics and Technology, Southwest Jiaotong University, Chengdu 610031 (China); Wei, L. F. [Quantum Optoelectronics Laboratory, School of Physics and Technology, Southwest Jiaotong University, Chengdu 610031 (China); State Key Laboratory of Optoelectronic Materials and Technologies, School of Physics and Engineering, Sun Yat-Sen University, Guangzhou 510275 (China)

    2011-11-15

    We propose an approach to sensitively probe the chirality of molecules by measuring their coherent optical-absorption spectra. It is shown that quantum dynamics of the cyclic three-level chiral molecules driven by appropriately designed external fields is total-phase dependent. This will result in chirality-dependent absorption spectra for the probe field. As a consequence, the charality-dependent information in the spectra (such as the locations and relative heights of the characteristic absorption peaks) can be utilized to identify molecular chirality and determinate enantiomer excess (i.e., the percentages of different enantiomers). The feasibility of the proposal with chiral molecules confined in hollow-core photonic crystal fiber is also discussed.

  10. Microwave absorption studies of MgB 2 superconductor

    Indian Academy of Sciences (India)

    Microwave absorption studies have been carried out on MgB2 superconductor using a standard X-band EPR spectrometer. The modulated low-field microwave absorption signals recorded for polycrystalline (grain size ∼ 10m) samples suggested the absence of weak-link character. The field dependent direct microwave ...

  11. Measurements of the Absorption by Auditorium SEATING—A Model Study

    Science.gov (United States)

    BARRON, M.; COLEMAN, S.

    2001-01-01

    One of several problems with seat absorption is that only small numbers of seats can be tested in standard reverberation chambers. One method proposed for reverberation chamber measurements involves extrapolation when the absorption coefficient results are applied to actual auditoria. Model seat measurements in an effectively large model reverberation chamber have allowed the validity of this extrapolation to be checked. The alternative barrier method for reverberation chamber measurements was also tested and the two methods were compared. The effect on the absorption of row-row spacing as well as absorption by small numbers of seating rows was also investigated with model seats.

  12. Experimental study of absorption of iron in foods using whole-body counter

    International Nuclear Information System (INIS)

    Nakamura, Tadamitsu

    1978-01-01

    Male rats of Wistar strain which showed normal hematological picture were given 59 Fe-labeled foods orally, and the iron absorption rate was determined by an animal whole body counter. When 59 Fe was given in a mixture with each of gruel, spinach, cow's milk, the yolk, and the yolk with orange juice, the iron absorption rates in each food were 9.4%, 8.9%, 6.6%, 10.8% and 7.2% respectively. None of these foods seemed to inhibit the 59 Fe absorption. When 59 Fe was given in a mixture with chicken, the iron absorption rate was 35.8%. This result suggested that the chicken promoted the 59 Fe absorption. When the yolk labeled in vivo with 59 Fe was given, the iron absorption rate was 4.9%. If the yolk labeled in vitro was used, the absorption rate was 10.8%. When the yolk labeled in vivo with 59 Fe was given with orange juice, the iron absorption rate was 13.3%. If the yolk labeled in vivo with 59 Fe was given, the absorption rate was 7.2%. Orange juice had no effect on the iron absorption when the yolk labeled in vitro was used. After chicken eggs labeled in vivo with 59 Fe was given to children, the iron absorption was determined by a whole body counter; the rate averaged 5.4 in the children without anemia and 24.7 in those with anemia. (Ueda, J.)

  13. Nonlinear bleaching, absorption, and scattering of 532-nm-irradiated plasmonic nanoparticles

    International Nuclear Information System (INIS)

    Liberman, V.; Sworin, M.; Kingsborough, R. P.; Geurtsen, G. P.; Rothschild, M.

    2013-01-01

    Single-pulse irradiation of Au and Ag suspensions of nanospheres and nanodisks with 532-nm 4-ns pulses has identified complex optical nonlinearities while minimizing material damage. For all materials tested, we observe competition between saturable absorption (SA) and reverse SA (RSA), with RSA behavior dominating for intensities above ∼50 MW/cm 2 . Due to reduced laser damage in single-pulse experiments, the observed intrinsic nonlinear absorption coefficients are the highest reported to date for Au nanoparticles. We find size dependence to the nonlinear absorption enhancement for Au nanoparticles, peaking in magnitude for 80-nm nanospheres and falling off at larger sizes. The nonlinear absorption coefficients for Au and Ag spheres are comparable in magnitude. On the other hand, the nonlinear absorption for Ag disks, when corrected for volume fraction, is several times higher. These trends in nonlinear absorption are correlated to local electric field enhancement through quasi-static mean-field theory. Through variable size aperture measurements, we also separate nonlinear scattering from nonlinear absorption. For all materials tested, we find that nonlinear scattering is highly directional and that its magnitude is comparable to that of nonlinear absorption. These results indicate methods to improve the efficacy of plasmonic nanoparticles as optical limiters in pulsed laser systems.

  14. Brown carbon absorption in the red and near-infrared spectral region

    Science.gov (United States)

    Hoffer, András; Tóth, Ádám; Pósfai, Mihály; Eddy Chung, Chul; Gelencsér, András

    2017-06-01

    Black carbon (BC) aerosols have often been assumed to be the only light-absorbing carbonaceous particles in the red and near-infrared spectral regions of solar radiation in the atmosphere. Here we report that tar balls (a specific type of organic aerosol particles from biomass burning) do absorb red and near-infrared radiation significantly. Tar balls were produced in a laboratory experiment, and their chemical and optical properties were measured. The absorption of these particles in the range between 470 and 950 nm was measured with an aethalometer, which is widely used to measure atmospheric aerosol absorption. We find that the absorption coefficient of tar balls at 880 nm is more than 10 % of that at 470 nm. The considerable absorption of red and infrared light by tar balls also follows from their relatively low absorption Ångström coefficient (and significant mass absorption coefficient) in the spectral range between 470 and 950 nm. Our results support the previous finding that tar balls may play an important role in global warming. Due to the non-negligible absorption of tar balls in the near-infrared region, the absorption measured in the field at near-infrared wavelengths cannot solely be due to soot particles.

  15. Absorption of Electro-magnetic Waves in a Magnetized Medium

    OpenAIRE

    Ganguly, Avijit K.; Konar, Sushan

    2000-01-01

    In continuation to our earlier work, in which the structure of the vacuum polarisation tensor in a medium was analysed in presence of a background electro-magnetic field, we discuss the absorptive part of the vacuum polarization tensor. Using the real time formalism of finite temperature field theory we calculate the absorptive part of 1-loop vacuum polarisation tensor in the weak field limit ($eB < m^2$). Estimates of the absorption probability are also made for different physical conditions...

  16. Effect of idler absorption in pulsed optical parametric oscillators.

    Science.gov (United States)

    Rustad, Gunnar; Arisholm, Gunnar; Farsund, Øystein

    2011-01-31

    Absorption at the idler wavelength in an optical parametric oscillator (OPO) is often considered detrimental. We show through simulations that pulsed OPOs with significant idler absorption can perform better than OPOs with low idler absorption both in terms of conversion efficiency and beam quality. The main reason for this is reduced back conversion. We also show how the beam quality depends on the beam width and pump pulse length, and present scaling relations to use the example simulations for other pulsed nanosecond OPOs.

  17. Calculation of effective absorption coefficient for aerosols of internal mixture

    International Nuclear Information System (INIS)

    Xu Bo; Huang Yinbo; Fan Chengyu; Qiao Chunhong

    2012-01-01

    The effective absorption coefficient with time of strong absorbing aerosol made of carbon dusts and water of internal mixture is analyzed, and the influence of different wavelengths and radius ratios on it is discussed. The shorter the wavelength is, the larger the effective absorption coefficient is , and more quickly it increases during 1-100 μs, and the largest increase if 132.65% during 1-100 μs. Different ratios between inner and outer radius have large influence on the effective absorption coefficient. The larger the ratio is, the larger the effective absorption coefficient is, and more quickly it increases during 1-100 μs. The increase of the effective absorption coefficient during 1-100 μs is larger than that during 100-1000 μs, and the largest increase is 138.66% during 1-100 μs. (authors)

  18. Simulation of solar-powered absorption cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Atmaca, I.; Yigit, A. [Uludag Univ., Bursa (Turkey). Dept. of Mechanical Engineering

    2003-07-01

    With developing technology and the rapid increase in world population, the demand for energy is ever increasing. Conventional energy will not be enough to meet the continuously increasing need for energy in the future. In this case, renewable energy sources will become important. Solar energy is a very important energy source because of its advantages. Instead of a compressor system, which uses electricity, an absorption cooling system, using renewable energy and kinds of waste heat energy, may be used for cooling. In this study, a solar-powered, single stage, absorption cooling system, using a water-lithium bromide solution, is simulated. A modular computer program has been developed for the absorption system to simulate various cycle configurations and solar energy parameters for Antalya, Turkey. So, the effects of hot water inlet temperatures on the coefficient of performance (COP) and the surface area of the absorption cooling components are studied. In addition, reference temperatures which are the minimum allowable hot water inlet temperatures are determined and their effect on the fraction of the total load met by non-purchased energy (FNP) and the coefficient of performance are researched. Also, the effects of the collector type and storage tank mass are investigated in detail. (author)

  19. Extreme Variability in a Broad Absorption Line Quasar

    Energy Technology Data Exchange (ETDEWEB)

    Stern, Daniel; Jun, Hyunsung D. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Mail Stop 169-221, Pasadena, CA 91109 (United States); Graham, Matthew J.; Djorgovski, S. G.; Donalek, Ciro; Drake, Andrew J.; Mahabal, Ashish A.; Steidel, Charles C. [California Institute of Technology, 1200 E. California Boulevard, Pasadena, CA 91125 (United States); Arav, Nahum; Chamberlain, Carter [Department of Physics, Virginia Tech, Blacksburg, VA 24061 (United States); Barth, Aaron J. [Department of Physics and Astronomy, 4129 Frederick Reines Hall, University of California, Irvine, CA 92697 (United States); Glikman, Eilat, E-mail: daniel.k.stern@jpl.nasa.gov [Department of Physics, Middlebury College, Middlebury, VT 05753 (United States)

    2017-04-20

    CRTS J084133.15+200525.8 is an optically bright quasar at z = 2.345 that has shown extreme spectral variability over the past decade. Photometrically, the source had a visual magnitude of V ∼ 17.3 between 2002 and 2008. Then, over the following five years, the source slowly brightened by approximately one magnitude, to V ∼ 16.2. Only ∼1 in 10,000 quasars show such extreme variability, as quantified by the extreme parameters derived for this quasar assuming a damped random walk model. A combination of archival and newly acquired spectra reveal the source to be an iron low-ionization broad absorption line quasar with extreme changes in its absorption spectrum. Some absorption features completely disappear over the 9 years of optical spectra, while other features remain essentially unchanged. We report the first definitive redshift for this source, based on the detection of broad H α in a Keck/MOSFIRE spectrum. Absorption systems separated by several 1000 km s{sup −1} in velocity show coordinated weakening in the depths of their troughs as the continuum flux increases. We interpret the broad absorption line variability to be due to changes in photoionization, rather than due to motion of material along our line of sight. This source highlights one sort of rare transition object that astronomy will now be finding through dedicated time-domain surveys.

  20. Absorption of carbon dioxide in waste tanks

    International Nuclear Information System (INIS)

    Hobbs, D.T.

    1987-01-01

    Air flow rates and carbon dioxide concentrations of air entering and exiting eight H-Area waste tanks were monitored for a period of one year. The average instanteous concentration of carbon dioxide in air is within the range reported offsite, and therefore is not affect by operation of the coal-fired power plant adjacent to the tank farm. Waste solutions in each of the tanks were observed to be continuously absorbing carbon dioxide. The rate of absorption of carbon dioxide decreased linearly with the pH of the solution. Personnel exposure associated with the routine sampling and analysis of radioactive wastes stored at SRP to determine the levels of corrosion inhibitors in solution could be reduced by monitoring the absorption of carbon dioxide and using the relationship between pH and carbon dioxide absorption to determine the free hydroxide concentration in solution

  1. Use of appropriate absorption coefficients in gamma-ray dosimetry

    International Nuclear Information System (INIS)

    Gopinath, D.V.; Natarajan, A.; Subbaiah, K.V.

    1985-01-01

    The current use of the different types of absorption coefficients in the computation of γ-ray energy deposition rates and air dose is critically analyzed. Transport calculations are presented to bring out the errors associated with the use of different absorption coefficients. It is observed that except for source energies in the range of 0.3 to 3.0 MeV the consistent use of the absorption coefficient, μ/sub a/ results in an underestimate of the air dose everywhere and of energy deposition at regions away from source. The underestimate becomes more significant with increased atomic number (Z) of the medium. Based on the computations and analysis it is concluded that the absorption coefficients μ/sub a/ and μ/sub k/ are of very limited use in practical γ-ray dosimetry

  2. Absorption of continuum radiation in a resonant expanding gaseous sphere

    International Nuclear Information System (INIS)

    Shaparev, N Y

    2014-01-01

    The paper deals with absorption of external continuum radiation in a self-similarly expanding gaseous sphere. Frequency probability and integral probability of radiation absorption in the resonance frequency range are determined depending on the expansion velocity gradient and thickness of the optical medium. It is shown that expansion results in a reduced optical thickness of the medium and enhanced integral absorption. (paper)

  3. Absorption corrections for x-ray fluorescence analysis of environmental samples

    International Nuclear Information System (INIS)

    Bazan, F.; Bonner, N.A.

    1975-01-01

    The discovery of a very simple and useful relationship between the absorption coefficient of a particular element and the ratio of incoherent to coherent scattering by the sample containing the element is discussed. By measuring the absorption coefficients for a few elements in a few samples, absorption coefficients for many elements in an entire set of similar samples can be obtained. (auth)

  4. Absorption corrections for x-ray fluorescence analysis of environmental samples

    International Nuclear Information System (INIS)

    Bazan, F.; Bonner, N.A.

    1976-01-01

    The discovery of a very simple and useful relationship between the absorption coefficient of a particular element and the ratio of incoherent to coherent scattering by the sample containing the element is discussed. By measuring the absorption coefficients for a few elements in a few samples, absorption coefficients for many elements in an entire set of similar samples can be obtained

  5. Ultrafast THz Saturable Absorption in Doped Semiconductors

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry; Hoffmann, Matthias C.

    2011-01-01

    We demonstrate ultrafast THz saturable absorption in n-doped semiconductors by nonlinear THz time-domain spectroscopy. This effect is caused by the semiconductor conductivity modulation due to electron heating and satellite-valley scattering in strong THz fields.......We demonstrate ultrafast THz saturable absorption in n-doped semiconductors by nonlinear THz time-domain spectroscopy. This effect is caused by the semiconductor conductivity modulation due to electron heating and satellite-valley scattering in strong THz fields....

  6. Gamma absorption meter

    International Nuclear Information System (INIS)

    Dincklage, R.D. von.

    1984-01-01

    The absorption meter consists of a radiation source, a trough for the absorbing liquid and a detector. It is characterized by the fact that there is a foil between the detector and the trough, made of a material whose binding energy of the K electrons is a little greater than the energy of the photons emitted by the radiation source. The source of radiation and foil are replaceable. (orig./HP) [de

  7. Total Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Rubio, B.; Gelletly, W.

    2007-01-01

    The problem of determining the distribution of beta decay strength (B(GT)) as a function of excitation energy in the daughter nucleus is discussed. Total Absorption Spectroscopy is shown to provide a way of determining the B(GT) precisely. A brief history of such measurements and a discussion of the advantages and disadvantages of this technique, is followed by examples of two recent studies using the technique. (authors)

  8. [Spectral absorption properties of the water constituents in the estuary of Zhujiang River].

    Science.gov (United States)

    Wang, Shan-shan; Wang, Yong-bo; Fu, Qing-hua; Yin, Bin; Li, Yun-mei

    2014-12-01

    Spectral absorption properties of the water constituents is the main factor affecting the light field under the surface of the water and the spectrum above the surface of the water. Thus, the study is useful for understanding of the water spectral property and the remote reversing of water quality parameters. Absorption properties of total suspended particles, non-algal particles, phytoplankton and CDOM were analyzed using the 30 samples collected in July 2013 in the estuary of Zhujiang River. The results indicated that: (1) the non-algal particles absorption dominated the absorption of the total suspended particles; (2) the absorption coefficient of the non-algal particles, which mainly came from the terrigenous deposits, decreased exponentially from short to long wavelength. In addition, the average value and spatial variation of the slope S(d) were higher than those in inland case- II waters; (3) the absorption coefficient of phytoplankton in 440 nm showed a better polynomial relationship with chlorophyll a concentration, while the absorption coefficient of phytoplankton in 675 nm linearly related with the chlorophyll a concentration. Moreover, the influence of accessory pigments on phytoplankton absorption coefficient mainly existed in the range of short wavelength, and Chlorophyll a was the main influencing factor for phytoplankton absorption in long wavelength. The specific absorption coefficient of phytoplankton decreased the power exponentially with the increase of the chlorophyll a concentration; (4) CDOM mainly came from the terrigenous sources and its spectral curve had an absorption shoulder between 250-290 nm. Thus, a piecewise S(g) fitting function could effectively express CDOM absorption properties, i.e., M value and S(g) value in period A (240-260 nm) showed a strong positive correlation. The M value was low, and the humic acid had a high proportion in CDOM; (5) the non-algal particles absorption dominated the total absorption in the estuary of

  9. XUV Absorption by Solid Density Aluminum

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, C A

    2009-09-21

    An inverse bremsstrahlung model for plasmas and simple metals that approximates the cold, solid Al experimental data below the L-edge is applied to matter conditions relevant to XUV laser applications. The model involves an all-order calculation using a semi-analytical effective electron-ion interaction. The predicted increases in XUV absorption with rising temperature occur via two effects: increased availability of final states from reduced electron degeneracy and a stronger electron-ion interaction from reduced screening. Discrepancies in the temperature dependence as well as other details between the present approach and a recently proposed absorption model are discussed.

  10. Restricted mass energy absorption coefficients for use in dosimetry

    International Nuclear Information System (INIS)

    Brahme, A.

    1977-02-01

    When matter is irradiated by a photon beam the fraction of energy absorbed locally in some region Rsub(Δ) (where the size of the region Rsub(Δ) is related to the range of secondary electrons of some restriction energy Δ) is expressed by the restricted mass energy absorption coefficient. In this paper an example is given of how restricted mass energy absorption coefficients can be calculated from existing differential photon interaction cross sections. Some applications of restricted mass absorption coefficients in dosimetry are also given. (B.D.)

  11. Study of Material Moisture Measurement Method and Instrument by the Combination of Fast Neutron Absorption and γ Absorption

    International Nuclear Information System (INIS)

    Hou Chaoqin; Gong Yalin; Zhang Wei; Shang Qingmin; Li Yanfeng; Gou Qiangyuan; Yin Deyou

    2010-01-01

    To solve the problem of on-line sinter moisture measurement in the iron making plant, we developed material moisture measurement method and instrument by the combination of fast neutron absorption and y-absorption. It overcomes the present existed problems of other moisture meters for the sinter. Compare with microwave moisture meter, the measurement dose not affected by conductance and magnetism of material; to infrared moisture meter, the measurement result dose not influenced by colour and light-reflect performance of material surface, dose not influenced by changes of material kind; to slow neutron scatter moisture meter, the measurement dose not affected by density of material and thickness of hopper wall; to the moisture measurement meter which combined by slow neutron penetrate through and y-absorption, there are definite math model and good linear relation between the measurement values, and the measurement dose not affected by material thickness, changes of material form and component. (authors)

  12. Urbach tails in the absorption spectra of semiconducting molybdenum-borate glasses

    International Nuclear Information System (INIS)

    Jamel Basha Adlan, M.; Wan Yusri Wan Yusuff; Tan, C.W.; Yam, F.K.

    1991-01-01

    The absorption curve of many amorphous compound semiconductors may be divided into three regions: (1) the high absorption region (α(w)≥10 4 cm -1 ), (2) an exponential region (1cm -1 ≤(w)≤10 4 cm -1 ) which obeys Urbach's rule and (3) a weak absorption tail (α(w)≤1cm -1 ). In this paper we will present the absorption edge of binary Molybdenum-Borate glasses at the exponential region of the spectra

  13. Radioisotope studies for quantitative measurement of manganese absorption

    International Nuclear Information System (INIS)

    Helbig, U.

    1981-01-01

    Purpose of the present study was to quantitatively determine the manganese absorption in growing rats by means of radioisotopes. First of all the following factors had to be investigated, which are significant for this determination: Measurability of stable and radioactive Mn in rat tissues; labelling of stable Mn and distribution of stable and radioactive Mn in the organism; verification of the isotope dilution method and of the comparative balance method with regard to its applicability for the determination of the true Mn absorption. We useed male and female Sprague-Dawley rats. The most important results are summarized in the following: in some separate tissues measurement of stable Mn was accompanied by difficulties. The measurement of radioactive Mn however, could be performed without any problems. 10 d after i.m. injection of 54 Mn only 17% of the administered Mn was still detectable in the organism. However, there was no uniform tissue labelling found. Therefore it is possible to an only restricted extent to draw quantitative conclusions on the content of stable Mn. A high percentage of stable and radioactive Mn was found above all in the liver. The isotope dilution method permits by feces analysis to differentiate between unabsorbed Mn coming from the food and endogenic Mn coming from the organism itself. The effective Mn absorption was also determined by means of the comparative balance method. By means of the isotope dilution method we determined the quantitative Mn-absorption with staged Mn administration and the contribution of absorption and excretion to the homeostatic regulation mechanisms of Mn. We found that absorption and excretion help the organism to keep an almost constant Mn concentration even with a differing Mn supply. (orig./MG) [de

  14. Gas absorption and discharge behaviors of lead-lithium

    International Nuclear Information System (INIS)

    Sakabe, Toshiro; Yokomine, Takehiko; Kunugi, Tomoaki; Kawara, Zensaku; Ueki, Yoshitaka; Tanaka, Teruya

    2014-01-01

    Highlights: • The absorption of argon in the lead-lithium is comparable with that of helium even at the solid state. • For the molten state of lead-lithium, the absorption of argon could be larger than that of helium. • It is observed that the argon tends to desorb when the phase change of lead-lithium occurs. • It is observed from the TPD-MS analysis that the argon tends to desorb when the phase change of lead-lithium occurs. - Abstract: The absorption of rare gas in the lead-lithium has been quite low and the gas is used as a cover-gas to control the environment of experiment. In our previous thermo-fluid experiment by using lithium-lead, it was found the cover gas pressure enclosed in the very leak tight container of lithium-lead was decreased with time, that is, the gas-absorption of the solid lithium-lead occurred at room temperature under atmospheric pressure. The variation of pressure exceeded the retention of argon in lead-lithium which is expected by the published data. Therefore, we aim to confirm those phenomena under well-controlled experimental condition by using argon, nitrogen and helium. According to the results of gas exposure tests, the absorption of argon in the lead-lithium is comparable with that of helium even at the solid state. For the molten state of lead-lithium, the absorption of argon could be larger than that of helium. It is also observed from the TPD-MS analysis that the argon tends to desorb when the phase change of lead-lithium occurs. If the retention of argon in the lead-lithium cannot be ignored, the problem of Ar-41 activity should be taken into consideration as well as the problem of argon bubble in the lead-lithium

  15. Mixture component effects on the in vitro dermal absorption of pentachlorophenol

    Energy Technology Data Exchange (ETDEWEB)

    Riviere, J.E.; Qiao, G.; Baynes, R.E.; Brooks, J.D. [Coll. of Veterinary Medicine, North Carolina State Univ., Raleigh, NC (United States); Mumtaz, M. [Agency for Toxic Substances and Disease Registry (ATSDR), Atlanta, GA (United States)

    2001-08-01

    Interactions between chemicals in a mixture and interactions of mixture components with the skin can significantly alter the rate and extent of percutaneous absorption, as well as the cutaneous disposition of a topically applied chemical. The predictive ability of dermal absorption models, and consequently the dermal risk assessment process, would be greatly improved by the elucidation and characterization of these interactions. Pentachlorophenol (PCP), a compound known to penetrate the skin readily, was used as a marker compound to examine mixture component effects using in vitro porcine skin models. PCP was administered in ethanol or in a 40% ethanol/60% water mixture or a 40% ethanol/60% water mixture containing either the rubefacient methyl nicotinate (MNA) or the surfactant sodium lauryl sulfate (SLS), or both MNA and SLS. Experiments were also conducted with {sup 14}C-labelled 3,3',4,4'-tetrachlorobiphenyl (TCB) and 3,3',4,4',5-pentachlorobiphenyl (PCB). Maximal PCP absorption was 14.12% of the applied dose from the mixture containing SLS, MNA, ethanol and water. However, when PCP was administered in ethanol only, absorption was only 1.12% of the applied dose. There were also qualitative differences among the absorption profiles for the different PCP mixtures. In contrast with the PCP results, absorption of TCB or PCB was negligible in perfused porcine skin, with only 0.14% of the applied TCB dose and 0.05% of the applied PCB dose being maximally absorbed. The low absorption levels for the PCB congeners precluded the identification of mixture component effects. These results suggest that dermal absorption estimates from a single chemical exposure may not reflect absorption seen after exposure as a chemical mixture and that absorption of both TCB and PCB are minimal in this model system. (orig.)

  16. Techniques For Measuring Absorption Coefficients In Crystalline Materials

    Science.gov (United States)

    Klein, Philipp H.

    1981-10-01

    Absorption coefficients smaller than 0.001 cm-1 can, with more or less difficulty, be measured by several techniques. With diligence, all methods can be refined to permit measurement of absorption coefficients as small as 0.00001 cm-1. Spectral data are most readily obtained by transmission (spectrophotometric) methods, using multiple internal reflection to increase effective sample length. Emissivity measurements, requiring extreme care in the elimination of detector noise and stray light, nevertheless afford the most accessible spectral data in the 0.0001 to 0.00001 cm-1 range. Single-wavelength informa-tion is most readily obtained with modifications of laser calorimetry. Thermo-couple detection of energy absorbed from a laser beam is convenient, but involves dc amplification techniques and is susceptible to stray-light problems. Photoacoustic detection, using ac methods, tends to diminish errors of these types, but at some expense in experimental complexity. Laser calorimetry has been used for measurements of absorption coefficients as small as 0.000003 cm-1. Both transmission and calorimetric data, taken as functions of intensity, have been used for measurement of nonlinear absorption coefficients.

  17. (EXAFS) X-ray absorption spectroscopy

    International Nuclear Information System (INIS)

    Craievich, A.F.

    1983-01-01

    The technique EXAFS (Extended X-Ray Absorption Fine Structure) is presented and its applications using the synchrotron radiation as an incidente beam in Science of Materials and Biophysics are shown. (L.C.) [pt

  18. A SURVEY OF ALKALI LINE ABSORPTION IN EXOPLANETARY ATMOSPHERES

    International Nuclear Information System (INIS)

    Jensen, Adam G.; Redfield, Seth; Endl, Michael; Cochran, William D.; Koesterke, Lars; Barman, Travis S.

    2011-01-01

    We obtained over 90 hr of spectroscopic observations of four exoplanetary systems with the Hobby-Eberly Telescope. Observations were taken in transit and out of transit, and we analyzed the differenced spectra—i.e., the transmission spectra—to inspect it for absorption at the wavelengths of the neutral sodium (Na I) doublet at λλ5889, 5895 and neutral potassium (K I) at λ7698. We used the transmission spectrum at Ca I λ6122—which shows strong stellar absorption but is not an alkali metal resonance line that we expect to show significant absorption in these atmospheres—as a control line to examine our measurements for systematic errors. We use an empirical Monte Carlo method to quantify these systematic errors. In a reanalysis of the same data set using a reduction and analysis pipeline that was derived independently, we confirm the previously seen Na I absorption in HD 189733b at a level of (– 5.26 ± 1.69) × 10 –4 (the average value over a 12 Å integration band to be consistent with previous authors). Additionally, we tentatively confirm the Na I absorption seen in HD 209458b (independently by multiple authors) at a level of (– 2.63 ± 0.81) × 10 –4 , though the interpretation is less clear. Furthermore, we find Na I absorption of (– 3.16 ± 2.06) × 10 –4 at <3σ in HD 149026b; features apparent in the transmission spectrum are consistent with real absorption and indicate this may be a good target for future observations to confirm. No other results (Na I in HD 147506b and Ca I and K I in all four targets) are significant to ≥3σ, although we observe some features that we argue are primarily artifacts.

  19. The Role of Trait and State Absorption in the Enjoyment of Music

    Science.gov (United States)

    2016-01-01

    Little is known about the role of state versus trait characteristics on our enjoyment of music. The aim of this study was to investigate the influence of state and trait absorption upon preference for music, particularly preference for music that evokes negative emotions. The sample consisted of 128 participants who were asked to listen to two pieces of self-selected music and rate the music on variables including preference and felt and expressed emotions. Participants completed a brief measure of state absorption after listening to each piece, and a trait absorption inventory. State absorption was strongly positively correlated with music preference, whereas trait absorption was not. Trait absorption was related to preference for negative emotions in music, with chi-square analyses demonstrating greater enjoyment of negative emotions in music among individuals with high trait absorption. This is the first study to show that state and trait absorption have separable and distinct effects on a listener’s music experience, with state characteristics impacting music enjoyment in the moment, and trait characteristics influencing music preference based on its emotional content. PMID:27828970

  20. Effect of meal composition on calcium absorption: enhancing effect of carbohydrate polymers

    International Nuclear Information System (INIS)

    Kelly, S.E.; Chawla-Singh, K.; Sellin, J.H.; Yasillo, N.J.; Rosenberg, I.H.

    1984-01-01

    Meal components including fat, fiber, and carbohydrates can influence the intestinal absorption of calcium; such interactions may be of even greater importance in the presence of intestinal disease. This study compares intestinal absorption of 47CaCl2 administered in four ways: in water, within a standard meal, with a liquid formula (Ensure, Ross Laboratories, Columbus, Ohio), or with a glucose polymer solution (Frodex-15, Ross). Studies were carried out in 9 patients with ileal resection, 3 patients with jejunoileal bypass, and 14 controls. Fractional calcium absorption from water was lower in patients than in controls. Absorption was enhanced 1.5- to 5-fold when 47CaCl2 was administered with a liquid formula diet containing a glucose polymer or with the glucose polymer alone. Patients with the lowest calcium absorption from breakfast showed the greatest effect of calcium ingestion with formula or glucose polymer. These findings further emphasize the importance of meal composition on calcium absorption and provide a possible mechanism for enhancing calcium absorption in some patients with chronically impaired absorption

  1. The Role of Trait and State Absorption in the Enjoyment of Music.

    Science.gov (United States)

    Hall, Sarah E; Schubert, Emery; Wilson, Sarah J

    2016-01-01

    Little is known about the role of state versus trait characteristics on our enjoyment of music. The aim of this study was to investigate the influence of state and trait absorption upon preference for music, particularly preference for music that evokes negative emotions. The sample consisted of 128 participants who were asked to listen to two pieces of self-selected music and rate the music on variables including preference and felt and expressed emotions. Participants completed a brief measure of state absorption after listening to each piece, and a trait absorption inventory. State absorption was strongly positively correlated with music preference, whereas trait absorption was not. Trait absorption was related to preference for negative emotions in music, with chi-square analyses demonstrating greater enjoyment of negative emotions in music among individuals with high trait absorption. This is the first study to show that state and trait absorption have separable and distinct effects on a listener's music experience, with state characteristics impacting music enjoyment in the moment, and trait characteristics influencing music preference based on its emotional content.

  2. A Review of Some Features of Radiowave Absorption | Iheonu ...

    African Journals Online (AJOL)

    . The analysis deals with absorption of radiowaves through the ionosphere using the absorption method – A3 (CW Field Strength) adopting data from the Swiss PTT MNIFTZ 4.1 computer predictions for shortwave transmission. The study gives ...

  3. Low-reflective wire-grid polarizers with absorptive interference overlayers

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Motofumi [Department of Micro Engineering, Kyoto University, Kyoto 606-8501 (Japan); Takada, Akio; Yamada, Takatoshi; Hayasaka, Takashi; Sasaki, Kouji; Takahashi, Eiji; Kumagai, Seiji, E-mail: m-snki@me.kyoto-u.ac.jp [Devices Technology Department, Devices Division, Sony Chemical and Information Device Corporation, 3-4-1 Sakuragi, Tagajyo, Miyagi 985-0842 (Japan)

    2010-04-30

    Wire-grid (WG) polarizers with low reflectivity for visible light have been successfully developed. We theoretically consider the optical properties of simple sandwich structures of absorptive layer/transparent layer (gap layer)/high-reflective mirrors and found that it is possible to develop an antireflection (AR) coating owing to the interference along with the absorption in the absorptive layer. A wide variety of materials can be used for AR coatings by tuning the thicknesses of both the absorptive and the gap layers. This AR concept has been applied to reduce the reflectance of WG polarizers of Al. FeSi{sub 2} as an absorptive layer has been deposited by the glancing angle deposition technique immediately on the top of Al wires covered with a thin SiO{sub 2} layer as a gap layer. For the optimum combination of the thicknesses of FeSi{sub 2} and SiO{sub 2}, the reflectance becomes lower than a few per cent, independent of the polarization, whereas the transmission polarization properties remain good. Because low-reflective (LR) WG polarizers are completely composed of inorganic materials, they are useful for applications requiring high-temperature durability such as liquid crystal projection displays.

  4. Gamm-ray absorption techniques

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1986-01-01

    In this chapter the principles of gamma-ray absorption are described and important applications in plant and process techniques such as measurement of thickness of deposits on pipes, checking for voids in concrete, metal corrosion, measurement of the density of materials inside vessels in industrial radiography are discussed. (U.K.)

  5. Thiamine absorption is not compromised in folate-deficient rats

    International Nuclear Information System (INIS)

    Walzem, R.L.; Clifford, A.J.

    1988-01-01

    Thiamine absorption and excretion were assessed in rats with severe folate deficiency (FD) by determining the fate of oral 3 H-labeled and intravenous 14 C-labeled thiamine over a 6-h test period. Thiamine status was evaluated in these same rats by measuring transketolase activity levels of blood before (TKA) and after (TPPE) addition of thiamine pyrophosphate to the incubation mixture of the assay procedure. Two additional experiments assessed active transport of thiamine and the effect of dietary succinylsulfathiazole (SST) on TKA and TPPE in rats with moderate FD. Intestinal absorption in general and thiamine absorption in particular and thiamine status were unaltered in rats with severe FD. Inanition associated with severe FD may impair thiamine status. Thiamine absorption by active transport was not compromised in FD, and dietary succinylsulfathiazole did not affect thiamine status

  6. Absorption and oxidation of no in ionic liquids

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention concerns the absorption and in situ oxidation of nitric oxide (NO) in the presence of water and oxygen in ionic liquid compositions at ambient temperature.......The present invention concerns the absorption and in situ oxidation of nitric oxide (NO) in the presence of water and oxygen in ionic liquid compositions at ambient temperature....

  7. Butyrate absorption and lactate secretion in ulcerative colitis

    DEFF Research Database (Denmark)

    Hove, H; Holtug, K; Jeppesen, P B

    1995-01-01

    .12. Despite normal butyrate absorption, sodium absorption was compromised in active ulcerative colitis (11.5 +/- 1.4 mumol/cm2/h) compared with quiescent (15.4 +/- 1.0 mumol/cm2/h) and controls (18.7 +/- 0.8 mumol/cm2/h) (P = 0.0006). Mucosal secretion of L-lactate was minimal in both healthy controls...

  8. Additional absorption of cosmic radio moises at microturbulences of ionosphere plasma

    International Nuclear Information System (INIS)

    Berezhko, E.G.; Gel'berg, M.G.; Krymskij, G.F.

    1987-01-01

    Electromagnetic wave interaction with a turbulent plasma of the ionosphere is considered. Electron scattering on plasma microturbulences is shown to result in supplementary wave absorption as compared with usual absorption conditioned by pair collisions. Effective frequency of collisions describing supplementary absorption essentially depends on frequency of the electromagnetic wave. The conducted estimations show that under the conditions of the high-latitude ionosphere accountancy of collective collisions may be important, particularly, it permits to explain anomalously steep spectra of riometric absorption

  9. Study of absorption spectra for alkali and alkaline earth metal salts in flameless atomic absorption spectrometry using a carbon tube atomizer

    International Nuclear Information System (INIS)

    Yasuda, Seiji; Kakiyama, Hitoo

    1975-01-01

    Absorption spectra of various salts such as alkali metal salts, alkaline earth dichlorides, and ammonium halides were investigated and absorptions of some molecular species produced in the carbon tube were identified. The aqueous solution (20 μl) containing 1.0 mg/ml of each salt was placed in the carbon tube atomizer and heated in a similar manner to usual flameless atomic absorption method. D 2 -lamp was used as a continuous light source and argon gas was employed as an inert sheath gas. The spectra were obtained over the range of wavelength 200 to 350 nm. When alkali halides were feeded, the absorption spectra agreed with those of alkali halide vapors. Therefore, in such cases vapors of the alkali halides were probably produced by the sublimation or vaporization in the atomizer. The spectra of alkali perchlorates were considered to be those of alkali chlorides produced by the pyrolysis of the perchlorates in the atomizer. The absorptions of alkaline earth chlorides below 250 nm were probably due to their gaseous states. Sulfur dioxide was found to be produced by the pyrolysis of alkali sulfates, bisulfates and sulfites in the atomizer, Alkali phosphates and pyrophosphates gave almost identical spectra below 300 nm. Gamma band spectrum of nitrogen monoxide was observed from 200 to 240 nm during ashing at bout 330 0 C for alkali nitrates and nitrites. Ammonia vapor was produced from ammonium halides during drying at about 170 0 C. Although the absorptions of alkali carbonates and hydroxides were almost undetectable, the same spectra as those of alkali halides were observed by the addition of ammonium halides to the solutions of alkali compounds. This shows that alkali halides are produced in the atomizer by the addition of halide ions. (auth.)

  10. The distribution of absorptive power dissipation in irradiated nanoparticulate system

    International Nuclear Information System (INIS)

    Li, Jiayu; Yang, Jian; Gu, Xiaobing

    2016-01-01

    The knowledge of local radiant absorption is important to the nanostructure optimization, it is beneficial to the applications in energy harvesting, optical heating, photocatalysis, etc. In this paper, FDTD model is constructed for the distribution of absorptive power dissipation in irradiated nanoparticulate system. The theoretical model extended from Mie theory is used to examine the FDTD model, the parameters and conditions set for FDTD simulation are confirmed based on the comparison. Then, the influence of Ag nanoparticle on the absorptive properties of nearby TiO_2 nanoparticle is investigated by FDTD simulation at the wavelength of 0.25 μm. It is indicated that suitable distance between TiO_2 and Ag particles is beneficial to the spectral radiant absorption of TiO_2 particle. Considering the agglomeration of nanoparticles and the oxidation at the TiO_2–Ag interface, the Ag core coated with Al_2O_3 shell is suggested, and the simulated results indicated that the shell thickness and the Ag core size need to be optimized for enhancing the radiant absorption of TiO_2 particle. - Highlights: • The absorptive power distribution in nanoparticulate system is simulated by FDTD. • FDTD simulation is compared with theoretical model extended from Mie theory. • The parameters and conditions are confirmed based on the comparison. • The influence of Ag nanoparticle on nearby TiO_2 particle's absorption is analyzed.

  11. Electrically tunable coherent optical absorption in graphene with ion gel.

    Science.gov (United States)

    Thareja, Vrinda; Kang, Ju-Hyung; Yuan, Hongtao; Milaninia, Kaveh M; Hwang, Harold Y; Cui, Yi; Kik, Pieter G; Brongersma, Mark L

    2015-03-11

    We demonstrate electrical control over coherent optical absorption in a graphene-based Salisbury screen consisting of a single layer of graphene placed in close proximity to a gold back reflector. The screen was designed to enhance light absorption at a target wavelength of 3.2 μm by using a 600 nm-thick, nonabsorbing silica spacer layer. An ionic gel layer placed on top of the screen was used to electrically gate the charge density in the graphene layer. Spectroscopic reflectance measurements were performed in situ as a function of gate bias. The changes in the reflectance spectra were analyzed using a Fresnel based transfer matrix model in which graphene was treated as an infinitesimally thin sheet with a conductivity given by the Kubo formula. The analysis reveals that a careful choice of the ionic gel layer thickness can lead to optical absorption enhancements of up to 5.5 times for the Salisbury screen compared to a suspended sheet of graphene. In addition to these absorption enhancements, we demonstrate very large electrically induced changes in the optical absorption of graphene of ∼3.3% per volt, the highest attained so far in a device that features an atomically thick active layer. This is attributable in part to the more effective gating achieved with the ion gel over the conventional dielectric back gates and partially by achieving a desirable coherent absorption effect linked to the presence of the thin ion gel that boosts the absorption by 40%.

  12. Satisfactory surgical option for cartilage graft absorption in microtia reconstruction.

    Science.gov (United States)

    Han, So-Eun; Oh, Kap Sung

    2016-04-01

    We routinely perform auricular elevation at least 6 months after implantation of framework in microtia reconstruction using costal cartilage. However, in a few cases, cartilage graft absorption has occurred, which has led to contour irregularity with unfavorable long-term results. In the present study, we recount the details of using additional rib cartilage augmentation to achieve an accentuated contour in cartilage graft absorption cases. The cartilage graft absorption was defined as contour irregularity or cartilage graft deformation as evaluated by the surgeon and patient. Depending on the extent of cartilage graft absorption, another rib cartilage framework was added to the previously implanted framework, targeting the absorption area. We used banked cartilage or harvested new cartilage based on three-dimensional rib computed tomography. Additional recontouring of framework was conducted in eight patients who were examined for cartilage graft absorption from 1.5 to 5 years after implantation of the framework. Four patients received additional rib cartilage augmentation and tissue expander insertion simultaneously prior to auricular elevation. Two patients underwent auricular elevation simultaneously. In another two patients, additional rib cartilage augmentation was performed before auricular elevation. The mean follow-up period was 18 months, and in all cases reconstructive results were acceptable. Although further follow-up evaluation is required, additional rib cartilage augmentation is an attractive surgical option for cartilage graft absorption cases. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Drug absorption from the irradiated rat small intestine in situ

    International Nuclear Information System (INIS)

    Venho, V.M.K.

    1976-01-01

    The absorption of acidic drugs phenobarbitone and sulphafurazole, basic drugs mecamylamine and quinidine, and a neutral drug isoniazid was studied in situ. Rats were irradiated 750 rad whole-body with 60 Co and the absorption experiment was done three and six days thereafter using the cannulated small intestine of urethane-anaesthetized rats. Drug disappearance from the intestinal lumen and drug levels in the whole blood and intestinal wall were measured. In control rats phenobarbitone showed the most rapid absorption and mecamylamine the slowest. Irradiation retarded the disappearance of all drugs from the intestinal lumen on the third postirradiation day. Fluid absorption was also diminished. On the sixth postirradiation day the absorption of phenobarbitone, sulphafurazole and mecamylamine had returned to the control level, but the absorption of quinidine and isoniazid was still retarded. After i.v. administration of drugs they were not significantly excreted into the intestinal contents and irradiation did not modify excretion. The distribution of drugs between the intestinal fluid and the intestinal wall was complete in the first 10 min of experiment. Mecamylamine and quinidine were lowered in the whole blood by irradiation. Blood levels of drugs did not correlate well to the rate of disappearance of drugs from the intestinal lumen. The reversible changes in absorption induced by irradiation are probably secondary effects of irradiation on intestinal morphology, permeability and transport capacity, composition, and possibly blood flow. (orig.) [de

  14. Spectroscopy of the 4.6 - 4.7 micron interstellar absorption features

    International Nuclear Information System (INIS)

    Geballe, T.R.

    1984-01-01

    Perhaps the most successful application of spectroscopy to the study of interstellar solid state infrared absorption features has been in the case of the previously unidentified feature near 4.6 μm first seen in absorption toward the protostar W33A. Whereas the original spectrum of this object, obtained at a resolving power of 70, revealed only a single deep absorption feature, a later spectrum, using a single channel grating spectrometer at ten times the resolving power, indicates that it is made up of three separate components. The central narrow absorption feature at 2140 cm -1 (4.67 μm) coincides in wavelength precisely with that of solid CO. It and its unresolved shoulder at just lower frequency have now been seen quite commonly in absorption toward other protostars. The broad absorption seen in W33A at 2165 cm -1 (4.62 μm) is apparently much less common. (author)

  15. Absorption of ozone, sulfur dioxide, and nitrogen dioxide by petunia plants

    Energy Technology Data Exchange (ETDEWEB)

    Elkiey, T.; Ormrod, D.P.

    1981-01-01

    Petunia plants (Petunia hybrida Vilm.) of three varieties with differing air pollutant sensitivities were grown in controlled environments and the absorption rates of ozone (O/sub 3/), sulfur dioxide (SO/sub 2/) and nitrogen dioxide (NO/sub 2/) determined during single gas and mixed gas exposures. Additional experiments were conducted to evaluate effects of duration of exposure, leaf age, and plant growth stage on absorption of O/sub 3/. Absorption of all pollutants from single gases or the mixture was generally greater for the more sensitive varieties. Absorption from single gases was generally greater than from the mixed gases. Absorption rates tended to decrease gradually throughout the day and from day to day with continuous exposure. Absorption of O/sub 3/ was proportional to exposure concentration and decreased with time at differing rates for each variety. More O/sub 3/ was absorbed by older than younger leaves and by plants at the early vegetative stage compared with those in the prefloral stage.

  16. Studies on the absorption, distribution of rare earth elements and its effect on absorption of phosphorus and potassium in sugarcane (Saccharum officnarum L.)

    International Nuclear Information System (INIS)

    Kuang Yanhua; Liu Qiongying; Zheng Yuemei; Deng Zhouhuo; Xu Shengjie

    1991-01-01

    Study on the absorption, distribution and translocation of area earth elements (RE) and their effects on absorption of phosphorus and potassium ( 86 Rb as tracer) in sugarcane showed that the sugarcane could absorb soluble RE fast by its root or leaves. Within the 1-7 days after treatment, the absorption rate of 141 Ce in organs of the plant increased with the time. At the 7th day after treatment, the absorption rate of 141 Ce by sugarcane plant reached the maximum which was about 2-3 times of that at the 1st day and after that it gradually decreased. The utilization efficiency of 141 Ce by sugarcane plant was 0.836-3.24%. The absorption and distribution of RE in sugarcane plant varied with the treatment methods. It was shown that about 90% 141 Ce in nutrient solution was concentrated in the roots while only about 10% of them was transferred into the shoots. The distribution and accumulation of 141 Ce in suggarcene plant was in order of root>stem>leaf. If smeared on the leaf of sugarcane, the distribution and accumulation of 141 Ce in sugarcane plant was in order of leaf>stem>root. When treated with 300, 500 and 800 ppm R(NO 3 ) 3 ·4H 2 O, Ce, La, Sm, Pr, Nd and Y, the absorption and translocation rate of phosphorus and rubidium in sugarcane were increased

  17. Determination of iron absorption and excretion by whole-body counting

    International Nuclear Information System (INIS)

    Hollard, D.; Benabid, Y.; Berard, M.; Bonnin, J.; Darnault, J.; Millet, M.

    1969-01-01

    Using a whole-body counter, the authors have studied 59 Fe absorption and loss in 8 normal subjects and in 30 iron deficient patients. Results showed that whole-body counting provided an excellent and simple method for iron retention measurements, obviating many inaccuracies of previous technic. Normal absorption of radio iron with this procedure has ranged from 9 per cent to 20 per cent of the administered tracer in normal subjects, with a mean of 15 per cent. A significant increase in 59 Fe absorption was noted in 21 iron-deficient patients in whom the retention ranged from 40 to 100 per cent. However, 3 iron-deficient patients were found to have low absorption, and their severe iron deficiency could be correlated with this defect in absorption. This method permits also the determination of the rate of iron excretion during the following months and therefore the study of the mechanism of some pathological loss. (authors) [fr

  18. Absorption of surface acoustic waves by topological insulator thin films

    International Nuclear Information System (INIS)

    Li, L. L.; Xu, W.

    2014-01-01

    We present a theoretical study on the absorption of the surface acoustic waves (SAWs) by Dirac electrons in topological insulator (TI) thin films (TITFs). We find that due to momentum and energy conservation laws, the absorption of the SAWs in TITFs can only be achieved via intra-band electronic transitions. The strong absorption can be observed up to sub-terahertz frequencies. With increasing temperature, the absorption intensity increases significantly and the cut-off frequency is blue-shifted. More interestingly, we find that the absorption of the SAWs by the TITFs can be markedly enhanced by the tunable subgap in the Dirac energy spectrum of the TI surface states. Such a subgap is absent in conventional two-dimensional electron gases (2DEGs) and in the gapless Dirac 2DEG such as graphene. This study is pertinent to the exploration of the acoustic properties of TIs and to potential application of TIs as tunable SAW devices working at hypersonic frequencies

  19. Acetaminophen (paracetamol) oral absorption and clinical influences.

    Science.gov (United States)

    Raffa, Robert B; Pergolizzi, Joseph V; Taylor, Robert; Decker, John F; Patrick, Jeffrey T

    2014-09-01

    Acetaminophen (paracetamol) is a widely used nonopioid, non-NSAID analgesic that is effective against a variety of pain types, but the consequences of overdose can be severe. Because acetaminophen is so widely available as a single agent and is increasingly being formulated in fixed-ratio combination analgesic products for the potential additive or synergistic analgesic effect and/or reduced adverse effects, accidental cumulative overdose is an emergent concern. This has rekindled interest in the sites, processes, and pharmacokinetics of acetaminophen oral absorption and the clinical factors that can influence these. The absorption of oral acetaminophen occurs primarily along the small intestine by passive diffusion. Therefore, the rate-limiting step is the rate of gastric emptying into the intestines. Several clinical factors can affect absorption per se or the rate of gastric emptying, such as diet, concomitant medication, surgery, pregnancy, and others. Although acetaminophen does not have the abuse potential of opioids or the gastrointestinal bleeding or organ adverse effects of NSAIDs, excess amounts can produce serious hepatic injury. Thus, an understanding of the sites and features of acetaminophen absorption--and how they might be influenced by factors encountered in clinical practice--is important for pain management using this agent. It can also provide insight for design of formulations that would be less susceptible to clinical variables. © 2013 World Institute of Pain.

  20. Absorption of cosmic radio noise at different frequencies at Sanae

    International Nuclear Information System (INIS)

    Steyn, T.F.J.

    1983-12-01

    Electron density profiles are simulated as a function of altitude for the D- and E-regions during disturbed ionospheric conditions using auroral absorption data from riometers recording cosmic radio noise at 20, 30 and 51 MHz at Sanae, Antarctica. An elliptical function was used to simulate, as a function of height, the electron density profiles. Using these profiles the measured absorption was calculated by utilizing the Appleton-Hartree treatment for radio waves crossing the ionosphere. The frequency dependence of the riometer absorption is represented by a power law of the frequency: A(f) = C.f -n , and values of n were determined from calculations of the absorptions from the simulated electron density profiles. This power law is a fairly accurate representation in the frequency range 20 to 51 MHz. It appears that the exponent of the power law and the height of maximum absorption are effective parameters to determine the hardness of the energy spectra of precipitating electrons. A method is discussed whereby interferences on the riometer recordings are filtered from the data. Quiet day curves are obtained by the superposition of successive riometer recordings with a period of one sidereal day. A Fourier series is fitted to the points of maximum density to represent the quiet day recordings. Absorption events on day 175 and day 178 (1982) are analized for each riometer frequency, and the hardness of the precipitating electrons is inferred from the n-values of power law presentation. It is shown that the absorption of cosmic radio noise increases by increasing the depth of ionization without increasing the ionization rate (number of electrons /m 3 ) in the upper D-region. This may mean that a hardening of a precipitation spectrum will increase the absorption of cosmic radio noise

  1. Upper limits for absorption by water vapor in the near-UV

    International Nuclear Information System (INIS)

    Wilson, Eoin M.; Wenger, John C.; Venables, Dean S.

    2016-01-01

    There are few experimental measurements of absorption by water vapor in the near-UV. Here we report the results of spectral measurements of water vapor absorption at ambient temperature and pressure from 325 nm to 420 nm, covering most tropospherically relevant short wavelengths. Spectra were recorded using a broadband optical cavity in the chemically controlled environment of an atmospheric simulation chamber. No absorption attributable to the water monomer (or the dimer) was observed at the 0.5 nm resolution of our system. Our results are consistent with calculated spectra and recent DOAS field observations, but contradict a report of significant water absorption in the near-UV. Based on the detection limit of our instrument, we report upper limits for the water absorption cross section of less than 5×10 −26 cm 2 molecule −1 at our instrument resolution. For a typical, indicative slant column density of 4×10 23 cm 2 , we calculate a maximum optical depth of 0.02 arising from absorption of water vapor in the atmosphere at wavelengths between 340 nm and 420 nm, with slightly higher maximum optical depths below 340 nm. The results of this work, together with recent atmospheric observations and computational results, suggest that water vapor absorption across most of the near-UV is small compared to visible and infrared wavelengths. - Highlights: • The absorption cross section of water vapor was studied from 325 to 420 nm. • The upper limit was 5×10 −26 cm 2 molecule −1 above 340 nm at 0.5 nm resolution. • Our result contradicts a recent report of appreciable absorption by water vapor.

  2. Absorption of lower hybrid waves by alpha particles in ITER

    International Nuclear Information System (INIS)

    Imbeaux, F.; Peysson, Y.; Eriksson, L.G.

    2003-01-01

    Absorption of lower hybrid (LH) waves by alpha particles may reduce significantly the current drive efficiency of the waves in a reactor or burning plasma experiment. This absorption is quantified for ITER using the ray-tracing+2D relativistic Fokker-Planck code Delphine. The absorption is calculated as a function of the superthermal alpha particle density, which is constant in these simulations, for two candidate frequencies for the LH system of ITER. Negligible absorption by alpha particles at 3.7 GHz requires n(alpha,supra) = 7.5 10 16 m -3 , while no significant impact on the driven current is found at 5 GHz, even if n(alpha,supra) = 1.5 10 18 m -3 . (authors)

  3. Enhanced microwave absorption properties of Ni-doped ordered mesoporous carbon/polyaniline nanocomposites

    International Nuclear Information System (INIS)

    Wang, Liuding; Wu, Hongjing; Shen, Zhongyuan; Guo, Shaoli; Wang, Yiming

    2012-01-01

    Highlights: ► OMC-Ni/PANI nanocomposites were prepared by in situ polymerization method. ► The effective absorption bandwidth was 4.7 GHz for OMC-Ni0.15/PANI. ► OMC-Ni/PANI showed excellent microwave absorption with respect to OMC-Ni. ► This effect could be mainly attributed to the improvement of impendence matching. - Abstract: We propose and demonstrate a new scheme to improve microwave absorption property through polyaniline (PANI)-functionalized Ni-doped ordered mesoporous carbon (OMC) by in situ polymerization method. The polymer-functionalized nanocomposites, embedding polyaniline within ordered mesoporous carbon, exhibit strong and broadband microwave absorption due to its better dielectric loss characteristic. OMC-Ni0.15/PANI exhibits an effective absorption bandwidth (i.e., reflection loss (RL) ≤ −10 dB) of 4.7 GHz and an absorption peak of −51 dB at 9.0 GHz. The absorption peak intensity and position can be tuned by controlling the thickness of the coating.

  4. Dielectric and microwave absorption properties of TiO_2/Al_2O_3 coatings and improved microwave absorption by FSS incorporation

    International Nuclear Information System (INIS)

    Yang, Zhaoning; Luo, Fa; Hu, Yang; Duan, Shichang; Zhu, Dongmei; Zhou, Wancheng

    2016-01-01

    In this paper, TiO_2/Al_2O_3 ceramic coatings were prepared by atmospheric plasma spraying (APS) technique. The phase composition and morphological characterizations of the synthesized TiO_2/Al_2O_3 powders and coatings were performed by X-ray diffraction and scanning electron microscopy (SEM), respectively. The dielectric properties of these coatings were discussed in the frequency range from 8.2 to 12.4 GHz (X-band). By calculating the microwave-absorption as a single-layer absorber, their microwave absorption properties were investigated at different content and thickness in details. Furthermore, by combination of the Frequency selective surface (FSS) and ceramic coatings, a double absorption band of the reflection loss spectra had been observed. The microwave absorbing properties of coatings both in absorbing intensity and absorbing bandwidth were improved. The reflection loss values of TiO_2/Al_2O_3 coatings exceeding −10 dB (larger than 90% absorption) can be obtained in the whole frequency range of X-band with 17 wt% TiO_2 content when the coating thickness is 2.3 mm. - Highlights: • Dielectric properties of TiO_2/Al_2O_3 ceramics fabricated by APS technique are reported for the first time. • Microwave absorption properties of TiO_2/Al_2O_3 composites are improved by FSS. • Reflection loss values exceeding −10 dB can be obtained in the whole X-band when coating thickness is 2.3 mm.

  5. Seasonal Solar Thermal Absorption Energy Storage Development.

    Science.gov (United States)

    Daguenet-Frick, Xavier; Gantenbein, Paul; Rommel, Mathias; Fumey, Benjamin; Weber, Robert; Gooneseker, Kanishka; Williamson, Tommy

    2015-01-01

    This article describes a thermochemical seasonal storage with emphasis on the development of a reaction zone for an absorption/desorption unit. The heat and mass exchanges are modelled and the design of a suitable reaction zone is explained. A tube bundle concept is retained for the heat and mass exchangers and the units are manufactured and commissioned. Furthermore, experimental results of both absorption and desorption processes are presented and the exchanged power is compared to the results of the simulations.

  6. Fundamental absorption edge of NiO nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Sokolov, V.I., E-mail: visokolov@imp.uran.ru [Institute of Metal Physics, Ural Branch of RAS, S. Kovalevskaya Street 18, 620990 Yekaterinburg (Russian Federation); Druzhinin, A.V. [Institute of Metal Physics, Ural Branch of RAS, S. Kovalevskaya Street 18, 620990 Yekaterinburg (Russian Federation); Kim, G.A. [Institute of Organic Synthesis Ural Branch of RAS, S. Kovalevskaya Street 20, 620990 Yekaterinburg (Russian Federation); Gruzdev, N.B.; Yermakov, A.Ye.; Uimin, M.A.; Byzov, I.V.; Shchegoleva, N.N.; Vykhodets, V.B.; Kurennykh, T.E. [Institute of Metal Physics, Ural Branch of RAS, S. Kovalevskaya Street 18, 620990 Yekaterinburg (Russian Federation)

    2013-12-01

    NiO nanocrystals with the average size of 5, 10 and 25 nm were synthesized by gas-condensation method. The well-defined increase of the optical density D near the fundamental absorption edge of NiO nanocrystals in the range of 3.5–4.0 eV observed after the annealing in air is caused by the oxygen content growth. It is the direct experimental evidence of the fact that p—d charge transfer transitions form the fundamental absorption edge.

  7. Fundamental absorption edge of NiO nanocrystals

    International Nuclear Information System (INIS)

    Sokolov, V.I.; Druzhinin, A.V.; Kim, G.A.; Gruzdev, N.B.; Yermakov, A.Ye.; Uimin, M.A.; Byzov, I.V.; Shchegoleva, N.N.; Vykhodets, V.B.; Kurennykh, T.E.

    2013-01-01

    NiO nanocrystals with the average size of 5, 10 and 25 nm were synthesized by gas-condensation method. The well-defined increase of the optical density D near the fundamental absorption edge of NiO nanocrystals in the range of 3.5–4.0 eV observed after the annealing in air is caused by the oxygen content growth. It is the direct experimental evidence of the fact that p—d charge transfer transitions form the fundamental absorption edge

  8. Swelling pressure and water absorption property of compacted granular bentonite during water absorption

    International Nuclear Information System (INIS)

    Oyamada, T.; Komine, H.; Murakami, S.; Sekiguchi, T.; Sekine, I.

    2012-01-01

    Document available in extended abstract form only. Bentonite is currently planned to be used as buffer materials in engineered barrier of radioactive waste disposal. Granular bentonites are expected as the materials used in constructions as buffer materials by in-situ compaction methods. After applying these buffer materials, it is expected that the condition of the buffer area changes in long-term by the seepage of groundwater into buffer area. Therefore, it is important to understand water movement and swelling behavior of the buffer materials for evaluating the performance of engineered barrier. In this study, we investigated water absorption property and swelling pressure of compacted granular bentonite. Specifically, the process of swelling pressure and amount of water absorption of granular bentonite-GX (Kunigel-GX, produced at the Tsukinuno mine in Japan) were observed by laboratory tests. To discuss the influence of maximum grain size of bentonite particle on swelling pressure and water absorption property, two types of samples were used. One is granular sample which is Bentonite-GX controlled under 2 mm the maximum grain size, the other is milled sample which is Bentonite-GX with the maximum grain size under 0.18 mm by milling with the agate mortar. In addition, the mechanism on the swelling pressure of compacted granular bentonite was considered and discussed. In the cases of granular sample, swelling pressure increases rapidly, then gradually continues to increase up to maximum value. In the cases of milled sample, swelling pressure also increases rapidly at first. However, then its value decreases before progressing of gradual increase continues. Especially, this trend was clearly observed at a relatively low dry density. At the peaks of these curves, the swelling pressure of granular samples is lower than that of milled samples. In addition, the increasing of swelling pressure by the time the peak observed during the process of swelling pressure from

  9. Absorptive coding metasurface for further radar cross section reduction

    Science.gov (United States)

    Sui, Sai; Ma, Hua; Wang, Jiafu; Pang, Yongqiang; Feng, Mingde; Xu, Zhuo; Qu, Shaobo

    2018-02-01

    Lossless coding metasurfaces and metamaterial absorbers have been widely used for radar cross section (RCS) reduction and stealth applications, which merely depend on redirecting electromagnetic wave energy into various oblique angles or absorbing electromagnetic energy, respectively. Here, an absorptive coding metasurface capable of both the flexible manipulation of backward scattering and further wideband bistatic RCS reduction is proposed. The original idea is carried out by utilizing absorptive elements, such as metamaterial absorbers, to establish a coding metasurface. We establish an analytical connection between an arbitrary absorptive coding metasurface arrangement of both the amplitude and phase and its far-field pattern. Then, as an example, an absorptive coding metasurface is demonstrated as a nonperiodic metamaterial absorber, which indicates an expected better performance of RCS reduction than the traditional lossless coding metasurface and periodic metamaterial-absorber. Both theoretical analysis and full-wave simulation results show good accordance with the experiment.

  10. Direct and quantitative photothermal absorption spectroscopy of individual particulates

    International Nuclear Information System (INIS)

    Tong, Jonathan K.; Hsu, Wei-Chun; Eon Han, Sang; Burg, Brian R.; Chen, Gang; Zheng, Ruiting; Shen, Sheng

    2013-01-01

    Photonic structures can exhibit significant absorption enhancement when an object's length scale is comparable to or smaller than the wavelength of light. This property has enabled photonic structures to be an integral component in many applications such as solar cells, light emitting diodes, and photothermal therapy. To characterize this enhancement at the single particulate level, conventional methods have consisted of indirect or qualitative approaches which are often limited to certain sample types. To overcome these limitations, we used a bilayer cantilever to directly and quantitatively measure the spectral absorption efficiency of a single silicon microwire in the visible wavelength range. We demonstrate an absorption enhancement on a per unit volume basis compared to a thin film, which shows good agreement with Mie theory calculations. This approach offers a quantitative approach for broadband absorption measurements on a wide range of photonic structures of different geometric and material compositions

  11. Spectrophotometer-Integrating-Sphere System for Computing Solar Absorptance

    Science.gov (United States)

    Witte, William G., Jr.; Slemp, Wayne S.; Perry, John E., Jr.

    1991-01-01

    A commercially available ultraviolet, visible, near-infrared spectrophotometer was modified to utilize an 8-inch-diameter modified Edwards-type integrated sphere. Software was written so that the reflectance spectra could be used to obtain solar absorptance values of 1-inch-diameter specimens. A descriptions of the system, spectral reflectance, and software for calculation of solar absorptance from reflectance data are presented.

  12. Absorptive routines and international patent performance

    Directory of Open Access Journals (Sweden)

    Fernando E. García-Muiña

    2017-04-01

    We enrich the treatment of the absorptive capacity phases including the moderating effects between routines associated to the traditional potential-realized absorptive capacities. Taking into account external knowledge search strategies, the deeper external relationships, the better transference and appropriation of specific external knowledge. Nevertheless, when the moderating role of assimilation is included, cooperation agreements appear as the most efficient source of external knowledge. Finally, we show that technological tools let firms store and structure the information making easier its use for international patenting. This positive effect is reinforced in the presence of exploitation routines, since technological knowledge will better fit to the industry's key factors of success.

  13. Absorption and emission spectroscopic characterisation of a pyrene-flavin dyad

    International Nuclear Information System (INIS)

    Shirdel, J.; Penzkofer, A.; Prochazka, R.; Shen, Z.; Strauss, J.; Daub, J.

    2007-01-01

    The pyrene-flavin (isoalloxazine) dyad, PFD {C 44 H 31 N 5 O 5 ; CA Index name: 1-pyrenepropanoic acid, α-[[4,10-dihydro-2,4-dioxo-10- phenylbenzo[g]pteridin-3(2H)-yl)acetyl]amino]-, phenylmethyl ester (αR)-(9Cl); CA Registry number: 618907-57-6}, dissolved in either dichloromethane or acetonitrile is characterized by absorption and emission spectroscopy. Absorption cross-section spectra, stimulated emission cross-section spectra, fluorescence quantum distributions, quantum yields, and degrees of fluorescence polarisation are determined. The fluorescence decay after femtosecond pulse excitation is determined by fluorescence up-conversion. The ground-state absorption recovery is determined by picosecond pump and probe transmission measurements. The dye photo-stability is investigated by observation of absorption spectral changes due to prolonged blue-light excitation. The absorption spectrum of PFD dyad resembles the superposition of the absorption of isoalloxazine (flavin) and 1-methylpyrene. Long-wavelength photo-excitation of the flavin moiety causes fluorescence quenching by ground-state electron transfer from pyrene to isoalloxazine. Short-wavelength photo-excitation of the pyrene moiety causes (i) excited-state electron transfer from pyrene to isoalloxazine, and (ii) Foerster-type energy transfer from pyrene to flavin followed by ground-state electron transfer from pyrene to flavin.

  14. Cosmic radio-noise absorption bursts caused by solar wind shocks

    Directory of Open Access Journals (Sweden)

    A. Osepian

    2004-09-01

    Full Text Available Bursts of cosmic noise absorption observed at times of sudden commencements (SC of geomagnetic storms are examined. About 300SC events in absorption for the period 1967-1990 have been considered. It is found that the response of cosmic radio-noise absorption to the passage of an interplanetary shock depends on the level of the planetary magnetic activity preceding the SC event and on the magnitude of the magnetic field perturbation associated with the SC (as measured in the equatorial magnetosphere. It is shown that for SC events observed against a quiet background (Kp<2, the effects of the SC on absorption can be seen only if the magnitude of the geomagnetic field perturbation caused by the solar wind shock exceeds a threshold value ΔBth. It is further demonstrated that the existence of this threshold value, ΔBth, deduced from experimental data, can be related to the existence of a threshold for exciting and maintaining the whistler cyclotron instability, as predicted by quasi-linear theory. SC events observed against an active background (Kp<2 are accompanied by absorption bursts for all magnetic field perturbations, however small. A quantitative description of absorption bursts associated with SC events is provided by the whistler cyclotron instability theory.

  15. Effect of absorbable and nonabsorbable sugars on intestinal calcium absorption in humans

    International Nuclear Information System (INIS)

    Griessen, M.; Speich, P.V.; Infante, F.; Bartholdi, P.; Cochet, B.; Donath, A.; Courvoisier, B.; Bonjour, J.P.

    1989-01-01

    The effects of glucose, galactose, and lactitol on intestinal calcium absorption and gastric emptying were studied in 9, 8, and 20 healthy subjects, respectively. Calcium absorption was measured by using a double-isotope technique and the kinetic parameters were obtained by a deconvolution method. The gastric emptying rate was determined with /sup 99m/Tc-diethylenetriaminepentaacetic acid and was expressed as the half-time of the emptying curve. Each subject was studied under two conditions: (a) with calcium alone and (b) with calcium plus sugar. Glucose and galactose increased the calcium mean transit time and improved the total fractional calcium absorption by 30% (p less than 0.02). Lactitol decreased the mean rate of absorption (p less than 0.001) and reduced the total fractional calcium absorption by 15% (p less than 0.001). The gastric emptying rate did not appear to influence directly the kinetic parameters of calcium absorption. These results show that both glucose and galactose exert the same stimulatory effect as lactose on calcium absorption in subjects with normal lactase whereas lactitol mimics the effects of lactose in lactase-deficient patients. Thus the absorbability of sugars determines their effect on calcium absorption

  16. Evolution of absorption machines; Evolution des machines a absorption

    Energy Technology Data Exchange (ETDEWEB)

    Soide, I; Klemsdal, E [Gaz de France (GDF), 75 - Paris (France); Le Goff, P; Hornut, J M [LSGC-ENSIC, 54 - Nancy (France)

    1998-12-31

    Most of todays absorption air-conditioning machineries use the lithium bromide-water pair. The most performing can operate at a 150-160 deg. C, the temperature being limited by the corrosion resistance of metals with respect to LiBr solutions. Also, there is a revival of interest for water-ammonia systems. These systems require the use of a rectification column which reduces the coefficient of performance. Higher thermal performances are reached with hydrocarbon pairs and ternary mixtures (water-methanol-LiBr etc..). This paper presents different schemes of refrigerating heat pumps based on these different systems. (J.S.)

  17. Evolution of absorption machines; Evolution des machines a absorption

    Energy Technology Data Exchange (ETDEWEB)

    Soide, I.; Klemsdal, E. [Gaz de France (GDF), 75 - Paris (France); Le Goff, P.; Hornut, J.M. [LSGC-ENSIC, 54 - Nancy (France)

    1997-12-31

    Most of todays absorption air-conditioning machineries use the lithium bromide-water pair. The most performing can operate at a 150-160 deg. C, the temperature being limited by the corrosion resistance of metals with respect to LiBr solutions. Also, there is a revival of interest for water-ammonia systems. These systems require the use of a rectification column which reduces the coefficient of performance. Higher thermal performances are reached with hydrocarbon pairs and ternary mixtures (water-methanol-LiBr etc..). This paper presents different schemes of refrigerating heat pumps based on these different systems. (J.S.)

  18. Leaf absorption of 32P in the pumpkin

    International Nuclear Information System (INIS)

    Chamel, Andre; Roux-Aubert, M.T.

    1964-04-01

    The author presents a method to study the influence of various factors of the absorption of 32 P applied under the form of phosphates by a plant cultivated in conditions ensuring a normal development. Experiments provided indications on leaf absorption and 32 P transport by pumpkin leaves: phosphor 32 is absorbed and then quickly transported into the different organs of the plant (24 hours after treatment, it is present in aerial and underground parts), the quantity of absorbed phosphor increases with phosphor concentration in the applied solution, atmosphere humidity is an important factor for phosphor penetration into the leaves, plants absorb phosphor in darkness as well as in light, and the absorption of phosphor is not modified when applied with low glucose concentrations [fr

  19. Absorption-reduced waveguide structure for efficient terahertz generation

    Energy Technology Data Exchange (ETDEWEB)

    Pálfalvi, L., E-mail: palfalvi@fizika.ttk.pte.hu [Institute of Physics, University of Pécs, Ifjúság ú. 6, 7624 Pécs (Hungary); Fülöp, J. A. [MTA-PTE High-Field Terahertz Research Group, Ifjúság ú. 6, 7624 Pécs (Hungary); Szentágothai Research Centre, University of Pécs, Ifjúság ú. 20, 7624 Pécs (Hungary); Hebling, J. [Institute of Physics, University of Pécs, Ifjúság ú. 6, 7624 Pécs (Hungary); MTA-PTE High-Field Terahertz Research Group, Ifjúság ú. 6, 7624 Pécs (Hungary); Szentágothai Research Centre, University of Pécs, Ifjúság ú. 20, 7624 Pécs (Hungary)

    2015-12-07

    An absorption-reduced planar waveguide structure is proposed for increasing the efficiency of terahertz (THz) pulse generation by optical rectification of femtosecond laser pulses with tilted-pulse-front in highly nonlinear materials with large absorption coefficient. The structure functions as waveguide both for the optical pump and the generated THz radiation. Most of the THz power propagates inside the cladding with low THz absorption, thereby reducing losses and leading to the enhancement of the THz generation efficiency by up to more than one order of magnitude, as compared with a bulk medium. Such a source can be suitable for highly efficient THz pulse generation pumped by low-energy (nJ-μJ) pulses at high (MHz) repetition rates delivered by compact fiber lasers.

  20. Terahertz gas sensor based on absorption-induced transparency

    Directory of Open Access Journals (Sweden)

    Rodrigo Sergio G.

    2016-01-01

    Full Text Available A system for the detection of spectral signatures of gases at the Terahertz regime is presented. The system consists in an initially opaque holey metal film whereby the introduction of a gas provokes the appearance of spectral features in transmission and reflection, due to the phenomenom of absorption-induced transparency (AIT. The peaks in transmission and dips in reflection observed in AIT occur close to the absorption energies of the molecules, hence its name. The presence of the gas would be thus revealed as a strong drop in reflectivity measurements at one (or several of the gas absorption resonances. As a proof of principle, we theoretically demonstrate how the AIT-based sensor would serve to detect tiny amounts of hydrocyanic acid.

  1. Effect of various absorption enhancers based on tight junctions on the intestinal absorption of forsythoside A in Shuang-Huang-Lian, application to its antivirus activity.

    Science.gov (United States)

    Zhou, Wei; Zhu, Xuan Xuan; Yin, Ai Ling; Cai, Bao Chang; Wang, Hai Dan; Di, Liuqing; Shan, Jin Jun

    2014-01-01

    Forsythoside A (FTA), one of the main active ingredients in Shuang-Huang-Lian (SHL), possesses strong antibacterial, antioxidant and antiviral effects, and its pharmacological effects was higher than that of other ingredients, but the absolute bioavailability orally was approximately 0.72%, which was significantly low, influencing clinical efficacies of its oral preparations seriously. In vitro Caco-2 cell and in vivo pharmacokinetics study were simultaneously performed to investigate the effects of absorption enhancers based on tight junctions: sodium caprate and water-soluble chitosan on the intestinal absorption of FTA, and the eventual mucosal epithelial damage resulted from absorption enhancers was evaluated by MTT test and morphology observation, respectively. The pharmacological effects such as antivirus activity improvement by absorption enhancers were verified by MDCK damage inhibition rate after influenza virus propagation. The observations from in vitro Caco-2 cell showed that the absorption of FTA in SHL could be improved by absorption enhancers. Meanwhile, the absorption enhancing effect of water-soluble chitosan may be almost saturable up to 0.0032% (w/v), and sodium caprate at concentrations up to 0.64 mg/mL was safe, but water-soluble chitosan at different concentrations was all safe for these cells. In pharmacokinetics study, water-soluble chitosan at dosage of 50 mg/kg improved the bioavailability of FTA in SHL to the greatest extent, and was safe for gastrointestine from morphological observation. Besides, treatment with SHL with water-soluble chitosan at dosage of 50 mg/kg prevented MDCK damage after influenza virus propagation better significantly than that of control. Water-soluble chitosan at dosage of 50 mg/kg might be safe and effective absorption enhancer for improving the bioavailability of FTA and the antivirus activity in vitro in SHL.

  2. Free-Free Absorption on Parsec Scales in Seyfert Galaxies

    Science.gov (United States)

    Roy, A. L.; Ulvestad, J. S.; Wilson, A. S.; Colbert, E. J. M.; Mundell, C. G.; Wrobel, J. M.; Norris, R. P.; Falcke, H.; Krichbaum, T.

    Seyfert galaxies come in two main types (types 1 and 2) and the difference is probably due to obscuration of the nucleus by a torus of dense molecular material. The inner edge of the torus is expected to be ionized by optical and ultraviolet emission from the active nucleus, and will radiate direct thermal emission (e.g. NGC 1068) and will cause free-free absorption of nuclear radio components viewed through the torus (e.g. Mrk 231, Mrk 348, NGC 2639). However, the nuclear radio sources in Seyfert galaxies are weak compared to radio galaxies and quasars, demanding high sensitivity to study these effects. We have been making sensitive phase referenced VLBI observations at wavelengths between 21 and 2 cm where the free-free turnover is expected, looking for parsec-scale absorption and emission. We find that free-free absorption is common (e.g. in Mrk 348, Mrk 231, NGC 2639, NGC 1068) although compact jets are still visible, and the inferred density of the absorber agrees with the absorption columns inferred from X-ray spectra (Mrk 231, Mrk 348, NGC 2639). We find one-sided parsec-scale jets in Mrk 348 and Mrk 231, and we measure low jet speeds (typically £ 0.1 c). The one-sidedness probably is not due to Doppler boosting, but rather is probably free-free absorption. Plasma density required to produce the absorption is Ne 3 2 105 cm-3 assuming a path length of 0.1 pc, typical of that expected at the inner edge of the obscuring torus.

  3. A low-cost vaporization-atomization system for atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bruhn F, C.G.; Ambiado V, F.; Woerner V, R.

    1990-01-01

    A low-cost vaporization-atomization system for atomic absorption spectrometry is developed as an alternative to the use of a graphite furnace in electrothermal atomic absorption spectrometry. (Author)

  4. Studies on the absorption and excretion of arsenic in test animals

    International Nuclear Information System (INIS)

    Mikulski, J.; Walczak, Z.; Politowski, M.

    1980-01-01

    The partition of arsenous compounds in cats between blood, lymph and urine has been studied by the isotopic method. The rate of poison absorption from the intestinal tract and poison excretion with urine have also been investigated. It was found that arsenic is evenly distributed between blood and lymph, but its concentration in urine is about 100 times larger. The rate of arsenic absorption is very high - the absorption time is of the order of minutes and the absorption is shortly followed by the appearance of arsenic in urine. (author)

  5. Derivation of water vapour absorption cross-sections in the red region

    Science.gov (United States)

    Lal, M.; Chakrabarty, D. K.

    1994-01-01

    Absorption spectrum in 436 to 448 nm wavelength region gives NO2 and O3 column densities. This spectrum can also give H2O column density. The spectrum in the range of 655 to 667 nm contains absorption due to NO3 and H2O. Combining the absorption spectra in the wavelength ranges of 436 to 448 and 655 to 667 nm, water vapor absorption cross-sections in this range comes out to be of the order of 2.0 x 10(exp -24) cm(exp -2).

  6. Neutron resonance absorption theory

    International Nuclear Information System (INIS)

    Reuss, P.

    1991-11-01

    After some recalls on the physics of neutron resonance absorption during their slowing down, this paper presents the main features of the theoretical developments performed by the french school of reactor physics: the effective reaction rate method so called Livolant-Jeanpierre theory, the generalizations carried out by the author, and the probability table method [fr

  7. Atomic absorption analysis of serial titanium alloys

    International Nuclear Information System (INIS)

    Gorlova, M.N.; Feofanova, N.M.; Kornyushkova, Yu.D.

    1977-01-01

    Atom-absorption technique is described, which makes it possible to rapidly and precisely determine the following alloying elements and admixtures in titanium alloys: Al (2.0 - 8.5%); Mo (0.5 - 8%); Cr (0.5 - 12%); Si (0.2 - 0.5%); Mn(0.2 - 2.5%); V(0.5 - 6%); Sn(2.0 - 3.0%); Fe(0.1 - 1.0%); Zr(2.0 - 12.0%). The atom absorption method with flame atomization of the sample provides for best results if the alloy is dissolved in a mixture HCl + HBF 4 in the ratio 2:1. In order to obtain correct results the standard solutions must contain titanium in concentrations corresponding to the weight of the sample being analyzed. Sensitivity of zirconium determination may be increased approximately twofold by adding 10 mg/ml of FeCl 3 into the solution. Being as precise, as the classic analytical methods, the atom absorption technique is about 5 times more efficient

  8. Intestinal absorption and secretion of 65Zn in the rat

    International Nuclear Information System (INIS)

    Methfessel, A.H.; Spencer, H.

    1974-01-01

    A single dose of 65 Zn Cl 2 was given by intubation to the intact rat or was instilled into the lumen of ligated intestinal sacs to determine the absorption, or injected intravenously via the tail vein to determine intestinal secretion of 65 Zn. Results indicated that the small intestine plays a major role in the absorption and secretion of zinc and that aging decreases the absorption of zinc for the duodenum of the rat

  9. The absorption and distribution of Cesium-134 in rice-soil system

    International Nuclear Information System (INIS)

    Xu Yinliang; Chen Chuanqun; Chen Bin; Sun Zhiming

    1991-01-01

    Dynamics of absorption of 134 Cs by rice shows that absorption rate is the fastest at boot stage; absorption capacities of 134 Cs in soils are different with the different physical-chemical properties of soils; absorption amounts vary with the time of irrigating 134 Cs; the closer the irrigation time to mature stage is, the more the absorption amount of 134 Cs in rice will be; the more the irrigating times are, and the higher the radioactivity of 134 Cs in irrigating water is, the more the absorption amount in rice will be. After brown rice is polished, contamination of 134 Cs can be decreased by 22.6-45.6%. The order of specific activity in rice is: bran > root > straw > husk > polished rice. Percentage activity of straw, brown rice, root and husk is 51.4%, 28.4%, 11.8% and 8.4% respectively. The migration of 134 Cs is very slow in soil and 95.1% of 134 Cs is concentrated in surface soil (0-2.5 cm). The distribution ratio of 134 Cs in the rice and soil is 6.1%:93.9%. Potassium ion can inhibit the absorption of 134 Cs by rice. There is an exponential function between the concentration of potassium ion and specific activity of 134 Cs in rice

  10. Absorption of Carbon Dioxide in Aqueous Solutions of N-methyldiethanolamine Mixtures

    Science.gov (United States)

    Ma’mun, S.; Svendsen, H. F.

    2018-05-01

    Carbon dioxide (CO2) is one of the greenhouse gases (GHG) that has contributed to the global warming problem. Carbon dioxide is produced in large quantity from coal-fired power plants, iron and steel production, cement production, chemical and petrochemical industries, natural gas purification, and transportation. Some efforts to reduce the CO2 emissions to the atmosphere are then required. Amine-based absorption may be an option for post-combustion capture. The objective of this study is to measure the effect of promoter addition as well as MDEA concentration for the CO2 absorption into the aqueous solutions of MDEA to improve its performances, i.e. increasing the absorption rate and the absorption capacity. Absorption of CO2 in aqueous solutions of MDEA mixtures were measured at 40 °C in a bubble tank reactor. The systems tested were the mixtures of 30 wt% MDEA with 5 and 10 wt% BEA and the mixtures of 40 and 50 wt% MDEA with 6 wt% AEEA. It was found that for MDEA-BEA-H2O mixtures, the higher the promoter concentraation the higher the CO2 absorption rate, while for the MDEA-AEEA-H2O mixtures, the higher the MDEA concentration the lower the CO2 absorption rate.

  11. Promises of Machine Learning Approaches in Prediction of Absorption of Compounds.

    Science.gov (United States)

    Kumar, Rajnish; Sharma, Anju; Siddiqui, Mohammed Haris; Tiwari, Rajesh Kumar

    2018-01-01

    The Machine Learning (ML) is one of the fastest developing techniques in the prediction and evaluation of important pharmacokinetic properties such as absorption, distribution, metabolism and excretion. The availability of a large number of robust validation techniques for prediction models devoted to pharmacokinetics has significantly enhanced the trust and authenticity in ML approaches. There is a series of prediction models generated and used for rapid screening of compounds on the basis of absorption in last one decade. Prediction of absorption of compounds using ML models has great potential across the pharmaceutical industry as a non-animal alternative to predict absorption. However, these prediction models still have to go far ahead to develop the confidence similar to conventional experimental methods for estimation of drug absorption. Some of the general concerns are selection of appropriate ML methods and validation techniques in addition to selecting relevant descriptors and authentic data sets for the generation of prediction models. The current review explores published models of ML for the prediction of absorption using physicochemical properties as descriptors and their important conclusions. In addition, some critical challenges in acceptance of ML models for absorption are also discussed. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Permeabilization of enterocytes induced by absorption of dietary fat

    DEFF Research Database (Denmark)

    Danielsen, Erik Michael; Hansen, Gert H; Rasmussen, Karina

    2013-01-01

    the physiological process of dietary fat absorption, and short exposures to the fat mixture caused fat droplet accumulation within villus enterocytes. Lucifer yellow (LY), a fluorescent membrane-impermeable polar tracer was included to monitor epithelial integrity. Both in controls and during fat absorption LY...

  13. Optical absorption of charged excitons in semiconducting carbon nanotubes

    DEFF Research Database (Denmark)

    Rønnow, Troels Frimodt; Pedersen, Thomas Garm; Cornean, Horia

    2012-01-01

    In this article we examine the absorption coefficient of charged excitons in carbon nanotubes. We investigate the temperature and damping dependence of the absorption spectra. We show that the trion peak in the spectrum is asymmetric for temperatures greater than approximately 1 K whereas...

  14. The Zone of Inertia: Absorptive Capacity and Organizational Change

    Science.gov (United States)

    Godkin, Lynn

    2010-01-01

    Purpose: The purpose of this paper is to describe how interruptions in organizational learning effect institutional absorptive capacity and contribute to organizational inertia. Design/methodology/approach: An exploratory model is presented as a heuristic to describe how interruptions in organizational learning affect absorptive capacity.…

  15. Correction for sample self-absorption in activity determination by gamma spectrometry

    International Nuclear Information System (INIS)

    Galloway, R.B.

    1991-01-01

    Gamma ray spectrometry is a convenient method of determining the activity of the radioactive components in environmental samples. Commonly samples vary in gamma absorption or differ in absorption from the calibration standards available, so that accurate correction for self-absorption in the sample is essential. A versatile correction procedure is described. (orig.)

  16. In Vitro Studies on the Absorption and Interactions of Zinc, Copper ...

    African Journals Online (AJOL)

    Background: The exact details of the processes of trace metals absorption and interactions in the gastro intestinal tract remain uncertain. Absorption for the most part, takes places in the small intestine. The exact site of maximum absorption, as defined either by kinetic rate or quantity has not been clearly defined. Similarly ...

  17. Scheme for achieving coherent perfect absorption by anisotropic metamaterials

    KAUST Repository

    Zhang, Xiujuan

    2017-02-22

    We propose a unified scheme to achieve coherent perfect absorption of electromagnetic waves by anisotropic metamaterials. The scheme describes the condition on perfect absorption and offers an inverse design route based on effective medium theory in conjunction with retrieval method to determine practical metamaterial absorbers. The scheme is scalable to frequencies and applicable to various incident angles. Numerical simulations show that perfect absorption is achieved in the designed absorbers over a wide range of incident angles, verifying the scheme. By integrating these absorbers, we further propose an absorber to absorb energy from two coherent point sources.

  18. Investigation of IR absorption spectra of oral cavity bacteria

    Science.gov (United States)

    Belikov, Andrei V.; Altshuler, Gregory B.; Moroz, Boris T.; Pavlovskaya, Irina V.

    1996-12-01

    The results of comparative investigation for IR and visual absorption spectra of oral cavity bacteria are represented by this paper. There are also shown the main differences in absorption spectra of such pure bacteria cultures as : E- coli, Candida, Staph, Epidermidis, and absorption spectra of bacteria colonies cultured in tooth root canals suspected to harbour several endodontical problems. The results of experimental research targeted to investigate an effect of such combined YAG:Nd and YAG:Cr; Tm; Ho laser parameters like: wavelength, energy density, average power and etc., to oral cavity bacteria deactivation are given finally.

  19. Optomechanically induced absorption in parity-time-symmetric optomechanical systems

    Science.gov (United States)

    Zhang, X. Y.; Guo, Y. Q.; Pei, P.; Yi, X. X.

    2017-06-01

    We explore the optomechanically induced absorption (OMIA) in a parity-time- (PT -) symmetric optomechanical system (OMS). By numerically calculating the Lyapunov exponents, we find out the stability border of the PT -symmetric OMS. The results show that in the PT -symmetric phase the system can be either stable or unstable depending on the coupling constant and the decay rate. In the PT -symmetric broken phase the system can have a stable state only for small gain rates. By calculating the transmission rate of the probe field, we find that there is an inverted optomechanically induced transparency (OMIT) at δ =-ωM and an OMIA at δ =ωM for the PT -symmetric optomechanical system. At each side of δ =-ωM there is an absorption window due to the resonance absorption of the two generated supermodes. Comparing with the case of optomechanics coupled to a passive cavity, we find that the active cavity can enhance the resonance absorption. The absorption rate at δ =ωM increases as the coupling strength between the two cavities increases. Our work provides us with a promising platform for controlling light propagation and light manipulation in terms of PT symmetry, which might have potential applications in quantum information processing and quantum optical devices.

  20. Electromagnetic-radiation absorption by water.

    Science.gov (United States)

    Lunkenheimer, P; Emmert, S; Gulich, R; Köhler, M; Wolf, M; Schwab, M; Loidl, A

    2017-12-01

    Why does a microwave oven work? How does biological tissue absorb electromagnetic radiation? Astonishingly, we do not have a definite answer to these simple questions because the microscopic processes governing the absorption of electromagnetic waves by water are largely unclarified. This absorption can be quantified by dielectric loss spectra, which reveal a huge peak at a frequency of the exciting electric field of about 20 GHz and a gradual tailing off toward higher frequencies. The microscopic interpretation of such spectra is highly controversial and various superpositions of relaxation and resonance processes ascribed to single-molecule or molecule-cluster motions have been proposed for their analysis. By combining dielectric, microwave, THz, and far-infrared spectroscopy, here we provide nearly continuous temperature-dependent broadband spectra of water. Moreover, we find that corresponding spectra for aqueous solutions reveal the same features as pure water. However, in contrast to the latter, crystallization in these solutions can be avoided by supercooling. As different spectral contributions tend to disentangle at low temperatures, this enables us to deconvolute them when approaching the glass transition under cooling. We find that the overall spectral development, including the 20 GHz feature (employed for microwave heating), closely resembles the behavior known for common supercooled liquids. Thus water's absorption of electromagnetic waves at room temperature is not unusual but very similar to that of glass-forming liquids at elevated temperatures, deep in the low-viscosity liquid regime, and should be interpreted along similar lines.

  1. Electromagnetic-radiation absorption by water

    Science.gov (United States)

    Lunkenheimer, P.; Emmert, S.; Gulich, R.; Köhler, M.; Wolf, M.; Schwab, M.; Loidl, A.

    2017-12-01

    Why does a microwave oven work? How does biological tissue absorb electromagnetic radiation? Astonishingly, we do not have a definite answer to these simple questions because the microscopic processes governing the absorption of electromagnetic waves by water are largely unclarified. This absorption can be quantified by dielectric loss spectra, which reveal a huge peak at a frequency of the exciting electric field of about 20 GHz and a gradual tailing off toward higher frequencies. The microscopic interpretation of such spectra is highly controversial and various superpositions of relaxation and resonance processes ascribed to single-molecule or molecule-cluster motions have been proposed for their analysis. By combining dielectric, microwave, THz, and far-infrared spectroscopy, here we provide nearly continuous temperature-dependent broadband spectra of water. Moreover, we find that corresponding spectra for aqueous solutions reveal the same features as pure water. However, in contrast to the latter, crystallization in these solutions can be avoided by supercooling. As different spectral contributions tend to disentangle at low temperatures, this enables us to deconvolute them when approaching the glass transition under cooling. We find that the overall spectral development, including the 20 GHz feature (employed for microwave heating), closely resembles the behavior known for common supercooled liquids. Thus water's absorption of electromagnetic waves at room temperature is not unusual but very similar to that of glass-forming liquids at elevated temperatures, deep in the low-viscosity liquid regime, and should be interpreted along similar lines.

  2. Effects of magnesium sulfate on the foliar absorption of phosphates at the pumpkin; Effets du sulfate de magnesium sur l'absorption foliaire de phosphates chez le potiron

    Energy Technology Data Exchange (ETDEWEB)

    Chamel, A

    1962-07-01

    The foliar absorption of phosphates labelled with {sup 32}P and applied with or without magnesium sulfate on the first leaf of pumpkin seedlings have been studied. The magnesium sulfate applied with the phosphate reduces plainly the absorption rate of {sup 32}P. (O.M.) [French] Nous avons etudie l'absorption foliaire de phosphates marques au {sup 32}P appliques, avec et sans sulfate de magnesium, sur la premiere feuille de jeunes plants de potirons. Le sulfate de magnesium applique avec le phosphate diminue nettement le taux d'absorption du {sup 32}P. (auteur)

  3. Electromagnetic absorption behaviour of ferrite loaded three phase carbon fabric composites

    Science.gov (United States)

    Jagatheesan, Krishnasamy; Ramasamy, Alagirusamy; Das, Apurba; Basu, Ananjan

    2018-02-01

    This article investigates the electromagnetic absorption behaviours of carbon helical yarn fabric reinforced composites and manganese-zinc (Mn-Zn) ferrite particles loaded 3 phase fabric composites. A carbon helical yarn having stainless steel core was prepared and made into single jersey knitted fabric. The composite was prepared by sandwiching a fabric with polypropylene films and thermal pressed. The absorption values of helical yarn fabric composite was observed to be less in the C band region (4-8 GHz). For improving the absorption coefficients of composite, Mn-Zn ferrite particles were dispersed in the polypropylene (PP) composite. The ferrite loaded PP composites exhibited better permittivity and permeability values, hence the absorption loss of the composite was improved. The helical yarn fabric reinforced with Mn-Zn ferrite/PP composite showed larger absorption coefficients than virgin PP/fabric composite. The change in thermal stability and particle size distribution in the Mn-Zn ferrite/PP composite was also analyzed. At higher ferrite concentration, bimodal particle distribution was observed which increased the conductivity and shielding effectiveness (SE) of the composite. In addition, complex permittivity value was also increased for higher incident frequency (4-8 GHz). As the ferrite content increases, the dielectric loss and magnetic permeability of PP/ferrite increases due to increased magnetic loss. Hence, ferrite loaded PP composite showed the total SE of -14.2 dB with the absorption coefficients of 0.717. The S1C7 fabric composite having ferrite dispersion showed the better absorption loss and lower reflection coefficient of 14.2 dB and 0.345 respectively compared to virgin PP/helical yarn fabric composite. The increasing ferrite content (45 wt%) improved the absorption loss and total SE. Though, ferrite based fabric composite exhibits moderate absorptive shielding, it can be used as shielding panels in the electronic industries.

  4. A review of lung-to-blood absorption rates for radon progeny

    International Nuclear Information System (INIS)

    Marsh, J. W.; Bailey, M. R.

    2013-01-01

    The International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model (HRTM) treats clearance of materials from the respiratory tract as a competitive process between absorption into blood and particle transport to the alimentary tract and lymphatics. The ICRP recommended default absorption rates for lead and polonium (Type M) in ICRP Publication 71 but stated that the values were not appropriate for short-lived radon progeny. This paper reviews and evaluates published data from volunteer and laboratory animal experiments to estimate the HRTM absorption parameter values for short-lived radon progeny. Animal studies showed that lead ions have two phases of absorption: ∼10 % absorbed with a half-time of ∼15 min, the rest with a half-time of ∼10 h. The studies also indicated that some of the lead ions were bound to respiratory tract components. Bound fractions, f b , for lead were estimated from volunteer and animal studies and ranged from 0.2 to 0.8. Based on the evaluations of published data, the following HRTM absorption parameter values were derived for lead as a decay product of radon: f r = 0.1, s r = 100 d -1 , s s = 1.7 d -1 , f b = 0.5 and s b = 1.7 d -1 . Effective doses calculated assuming these absorption parameter values instead of a single absorption half-time of 10 h with no binding (as has generally been assumed) are only a few per cent higher. However, as there is some conflicting evidence on the absorption kinetics for radon progeny, dose calculations have been carried out for different sets of absorption parameter values derived from different studies. The results of these calculations are discussed. (authors)

  5. Plutonium and neptunium absorption from the gastrointestinal tract of neonatal baboons

    International Nuclear Information System (INIS)

    Lataillade, Ghislaine; Duserre, Claude; Rateau, Gerard; Verry, Monique; Fritsch, Paul; Metivier, Henri

    1992-06-01

    Nineteen baboons aged 1 to 310 days were given oral doses of 238 Pu citrate or 239 Np nitrate. Gastrointestinal (GI) absorption of Pu and Np were higher than those observed in adults. The values of Pu GI absorption were 0.22% at 1 d, 0.17% at 17 d then about 0.10% until 177 d of age. From 195 d onwards, GI absorption was about 0.02% vs adult values (0.008%). GI absorption of neptunium decreased rapidly with age from 1.71% at 4 d to 0.14% at 6 d and remained at this value until 26 d. From 77 d onwards Np GI absorption was decreased to adult value (0.042%). Gastrointestinal retention associated with GI absorption was small, below 0.4% for Pu and 0.2% for Np. Np and Pu was mainly retained in the small intestine. Pu was retained in the ileum wall till 66 d, and afterwards in the duodenum wall. Histological study of Pu retention showed that it was confined to the macrophages under the ileum villi epithelial cells. Np did not seem to have a well-defined retention compartment. Retention occurred first in the ileum wall up to 6 d, afterwards it was divided between the ileum and duodenum walls up to 77 d and finally, between the duodenum and jejunum walls from 132 days of age onwards. The study shows a difference between Np and Pu GI absorption in neonatal baboons. Np GI absorption decreased to adult value in less than 3 months whereas Pu GI absorption decreased to adult value within 195 days. Our Pu results demonstrated that, the tenfold increase of actinides gastrointestinal transfer proposed by ICRP up to 12 months of age in newborn humans seems acceptable. (authors) [fr

  6. Polarization control of multi-photon absorption under intermediate femtosecond laser field

    International Nuclear Information System (INIS)

    Cheng Wenjing; Liang Guo; Wu Ping; Liu Pei; Jia Tianqing; Sun Zhenrong; Zhang Shian

    2017-01-01

    It has been shown that the femtosecond laser polarization modulation is a very simple and well-established method to control the multi-photon absorption process by the light–matter interaction. Previous studies mainly focused on the multi-photon absorption control in the weak field. In this paper, we further explore the polarization control behavior of multi-photon absorption process in the intermediate femtosecond laser field. In the weak femtosecond laser field, the second-order perturbation theory can well describe the non-resonant two-photon absorption process. However, the higher order nonlinear effect (e.g., four-photon absorption) can occur in the intermediate femtosecond laser field, and thus it is necessary to establish new theoretical model to describe the multi-photon absorption process, which includes the two-photon and four-photon transitions. Here, we construct a fourth-order perturbation theory to study the polarization control behavior of this multi-photon absorption under the intermediate femtosecond laser field excitation, and our theoretical results show that the two-photon and four-photon excitation pathways can induce a coherent interference, while the coherent interference is constructive or destructive that depends on the femtosecond laser center frequency. Moreover, the two-photon and four-photon transitions have the different polarization control efficiency, and the four-photon absorption can obtain the higher polarization control efficiency. Thus, the polarization control efficiency of the whole excitation process can be increased or decreased by properly designing the femtosecond laser field intensity and laser center frequency. These studies can provide a clear physical picture for understanding and controlling the multi-photon absorption process in the intermediate femtosecond laser field, and also can provide a theoretical guidance for the future experimental realization. (paper)

  7. Statistical evidences of absorption at high latitudes

    International Nuclear Information System (INIS)

    Fesenko, B.I.

    1980-01-01

    Evidences are considered which indicate to the significant effect of the irregular interstellar absorption at high latitudes b. The number density of faint galaxies grows with the increasing |b| even at the values of |b| exceeding 50 deg. The effects of interstellar medium are traced even in the directions of the stars and globular clusters with very low values of the colour excess. The coefficient of absorption, Asub(B)=0.29+-0.05, was estimated from the colours of the bright E-galaxies [ru

  8. Fat digestion and absorption in spice-pretreated rats.

    Science.gov (United States)

    Prakash, Usha N S; Srinivasan, Krishnapura

    2012-02-01

    A few common spices are known to stimulate secretion of bile with higher amount of bile acids which play a major role in digestion and absorption of dietary lipids. It would be appropriate to verify if these spices enable efficient digestion and absorption during high-fat intake. In this context, dietary ginger (0.05%), piperine (0.02%), capsaicin (0.015%), and curcumin (0.5%) were examined for their influence on bile secretion, digestive enzymes of pancreas and absorption of dietary fat in high-fat (30%) fed Wistar rats for 8 weeks. These spices enhanced the activity of pancreatic lipase, amylase, trypsin and chymotrypsin by 22-57%, 32-51%, 63-81% and 12-38%, respectively. Dietary intake of spices along with high-fat enhanced fat absorption. These dietary spices increased bile secretion with higher bile acid content. Stimulation of lipid mobilisation from adipose tissue was suggested by the decrease in perirenal adipose tissue weight by dietary capsaicin and piperine. This was also accompanied by prevention of the accumulation of triglyceride in liver and serum in high-fat fed rats. Activities of key lipogenic enzymes in liver were reduced which was accompanied by an increased activity of hormone-sensitive lipase. Thus, dietary ginger and other spice compounds enhance fat digestion and absorption in high-fat fed situation through enhanced secretion of bile salts and a stimulation of the activity pancreatic lipase. At the same time, the energy expenditure is facilitated by these spices to prevent the accumulation of absorbed fat. Copyright © 2011 Society of Chemical Industry.

  9. Perspective of Chinese Forest Carbon Absorption Trade Based on Low-Carbon Economy

    OpenAIRE

    Wang, Ming-gang

    2011-01-01

    The paper analyzes the basis of forest carbon trade including me feasibility of carbon absorption trade, main body, platform and standard. The purposes of capital of carbon absorption trade is introduced. Caron absorption trade capital can be used to resettle ecological migrants, absorb employment, build forest and increase fund, increase local income, enhance forest science and technology development and launch environmental proportion. The perspective of developing forest carbon absorption ...

  10. Reflection effect of localized absorptive potential on non-resonant and resonant tunneling

    International Nuclear Information System (INIS)

    Rubio, A.; Kumar, N.

    1992-06-01

    The reflection due to absorptive potential (-iV i ) for resonant and non-resonant tunneling has been considered. We show that the effect of reflection leads to a non-monotonic dependence of absorption on the strength V i with a maximum absorption of typically 0.5. This has implications for the operation of resonant tunneling devices. General conceptual aspects of absorptive potentials are discussed. (author). 9 refs, 2 figs

  11. Absorption of plant-incorporated nuclear fuel cycle elements from the gastro-intestinal tract

    International Nuclear Information System (INIS)

    Sullivan, M.F.; Garland, T.R.; Cataldo, D.A.; Schreckhise, R.G.

    1979-01-01

    Soybean plants (Glycine max cv Williams) grown hydroponically on solutions containing ammonium pertechnetate ( 95 Tcsup(m)O - 4 ) were fed to rats (omnivores) and guinea pigs (herbivores). Absorption of plant-incorporated technetium was compared with absorption of inorganic 95 Tcsup(m) from a gavaged solution or with absorption of 95 Tcsup(m) added to non-radioactive soybean tissues. In a second study absorption of plutonium from alfalfa (Medicago sativa cv Ladak) grown on soil amended with either 238 Pu nitrate or 238 Pu-DTPA was compared with absorption of gavaged 238 Pu solutions and 238 Pu mixed with non-radioactive alfalfa. Incorporation of 95 Tcsup(m) into soybean tissues resulted in decreased absorption by both animal species. In contrast, incorporation of 238 Pu in alfalfa resulted in an increased absorption when compared with controls that were administered inorganic 238 Pu. These results suggest that organic binding may alter, in either direction, absorption of nuclear fuel cycle elements. (author)

  12. Picosecond absorption relaxation measured with nanosecond laser photoacoustics

    OpenAIRE

    Danielli, Amos; Favazza, Christopher P.; Maslov, Konstantin; Wang, Lihong V.

    2010-01-01

    Picosecond absorption relaxation—central to many disciplines—is typically measured by ultrafast (femtosecond or picosecond) pump-probe techniques, which however are restricted to optically thin and weakly scattering materials or require artificial sample preparation. Here, we developed a reflection-mode relaxation photoacoustic microscope based on a nanosecond laser and measured picosecond absorption relaxation times. The relaxation times of oxygenated and deoxygenated hemoglobin molecules, b...

  13. Konference Distillation and Absorption 2010

    Czech Academy of Sciences Publication Activity Database

    Bendová, Magdalena

    2009-01-01

    Roč. 103, č. 10 (2009), s. 862 ISSN 0009-2770 R&D Projects: GA MŠk LA320 Institutional research plan: CEZ:AV0Z40720504 Keywords : conference * announcement * distillation and absorption Subject RIV: CF - Physical ; Theoretical Chemistry

  14. Photoinduced absorption of Ag nanoparticles deposited on ITO substrate

    Energy Technology Data Exchange (ETDEWEB)

    Ozga, K., E-mail: cate.ozga@wp.pl [Chair of Public Health, Czestochowa University of Technology, Al. Armii Krajowej 36B, 42-200 Czestochowa (Poland); Oyama, M. [Department of Material Chemisrty, Graduate School of Engineering, Kyoto University, Nishikyo-ku, Kyoto 615-8520 (Japan); Szota, M. [Institute of Materials Science and Engineering, Technical University of Czestochowa, al. Armii Krajowej 19, 42-200 Czestochowa (Poland); Nabialek, M. [Institute of Physics, Czestochowa University of Technology, Al. Armii Krajowej 19, 42-200 Czestochowa (Poland); Kityk, I.V. [Electrical Engineering Department, Czestochowa University of Technology, Al. Armii Krajowej 17/19, 42-200 Czestochowa (Poland); Slezak, A. [Chair of Public Health, Czestochowa University of Technology, Al. Armii Krajowej 36B, 42-200 Czestochowa (Poland); Umar, A.A. [Institute of Micronegineering and Nanoelectronics Universiti Kebangsaan Malaysia 43600 UKM bangi, Selangor D.E. (Malaysia); Nouneh, K. [INANOTECH, Institute of Nanomaterials and Nanotechnology, MAScIR (Moroccan Advanced Science, Innovation and Research Foundation), ENSET, Av. Armee Royale, 10100, Rabat (Morocco)

    2011-06-15

    Research highlights: > We study photoinduced absorption for two Ag NP deposited on the ITO. > The higher resistance eof the NP favors larger photoinduced changes. > Principal role is played by nanointerfaces. - Abstract: Substantial changes of absorption after illumination by 300 mW continuous wave green laser at 532 nm were observed. The effect of indium tin oxide (ITO) substrate was explored versus Ag nanoparticles (AgNPs) size, their regularity and surface plasmon resonance. The ITO substrate features play a crucial role for the formation of homogenous AgNPs. The attachments of AgNPs on ITO surface as well as their homogeneity are significantly changed under the influence of the laser treatment. We study the Ag NP deposited on the two different substrates which play a crucial role in the photoinduced absorption. The dependence of the photoinduced absorption versus the time of optical treatment is explained within a framework of the photopolarization of the particular trapping levels on the borders between the ITO substrate and the Ag NP.

  15. Absorber performance of a water/lithium-bromide absorption chiller

    International Nuclear Information System (INIS)

    Xie Guozhen; Sheng Guogang; Bansal, Pradeep Kumar; Li, Guang

    2008-01-01

    An absorber is one of the most important components of a lithium-bromide absorption chiller (LBAC) as its absorbing characteristics directly influence the performance of the whole chiller. It has been indicated that the absorbing efficiency and cooling capacity could be improved by increasing the solution concentration. In this paper, based on the mechanism of falling film absorption on horizontal tubes, the theoretical models of falling film absorption on horizontal tubes have been established. A series of programs used for computing the theoretical mathematical models, including simulation of LBAC cycle and falling film absorption, have been programmed. The models have been validated reasonably by the experimental data. The results show that the cooling capacity of the LBAC varies in parabola shape of curve with the solution concentration from 52.5% to 58.5%, and that the best coefficient of performance (COP) occurs at concentration of 57%. The investigation proposes the absorbing process of sub-steady thermodynamic equilibrium for the duality solution under increase absorbing pressure

  16. Rich magneto-absorption spectra of AAB-stacked trilayer graphene.

    Science.gov (United States)

    Do, Thi-Nga; Shih, Po-Hsin; Chang, Cheng-Peng; Lin, Chiun-Yan; Lin, Ming-Fa

    2016-06-29

    A generalized tight-binding model is developed to investigate the feature-rich magneto-optical properties of AAB-stacked trilayer graphene. Three intragroup and six intergroup inter-Landau-level (inter-LL) optical excitations largely enrich magneto-absorption peaks. In general, the former are much higher than the latter, depending on the phases and amplitudes of LL wavefunctions. The absorption spectra exhibit single- or twin-peak structures which are determined by quantum modes, LL energy spectra and Fermion distribution. The splitting LLs, with different localization centers (2/6 and 4/6 positions in a unit cell), can generate very distinct absorption spectra. There exist extra single peaks because of LL anti-crossings. AAB, AAA, ABA, and ABC stackings considerably differ from one another in terms of the inter-LL category, frequency, intensity, and structure of absorption peaks. The main characteristics of LL wavefunctions and energy spectra and the Fermi-Dirac function are responsible for the configuration-enriched magneto-optical spectra.

  17. Fundamental absorption edge of CdP2 single crystals

    International Nuclear Information System (INIS)

    Bondar', G.I.; Koval', V.S.; Kurik, M.V.

    1986-01-01

    Fundamental absorption edge of tetragonal CdP 2 crystals is investigated within the temperature range of 4.2-293 K. The crystals are grown by the Bridgman methods and resublimation methods and possess different degree of perfection and purity. In perfect CdP 2 crystals with small concentration of impurities in the region of K > 20 cm -1 the shape of the absorption edge spectrum is described by the Urbach rule. The Urbach rule parameters are defined. The electron-phonon interaction is shown to be the determinant at K > 20 cm -1 and the direct vertical transition is observed. A slight additional absorption with maximum at 2.163 eV within the range of K -1 and at T ≤ 50 is associated with transition from shallow acceptor level to the conduction zone. The impurity leads to the shift of the fundamental absorption edge to the long-wavelength side and diffusion of electrons on impurities is resulted

  18. Dielectric Characteristics and Microwave Absorption of Graphene Composite Materials

    Directory of Open Access Journals (Sweden)

    Kevin Rubrice

    2016-10-01

    Full Text Available Nowadays, many types of materials are elaborated for microwave absorption applications. Carbon-based nanoparticles belong to these types of materials. Among these, graphene presents some distinctive features for electromagnetic radiation absorption and thus microwave isolation applications. In this paper, the dielectric characteristics and microwave absorption properties of epoxy resin loaded with graphene particles are presented from 2 GHz to 18 GHz. The influence of various parameters such as particle size (3 µm, 6–8 µm, and 15 µm and weight ratio (from 5% to 25% are presented, studied, and discussed. The sample loaded with the smallest graphene size (3 µm and the highest weight ratio (25% exhibits high loss tangent (tanδ = 0.36 and a middle dielectric constant ε′ = 12–14 in the 8–10 GHz frequency range. As expected, this sample also provides the highest absorption level: from 5 dB/cm at 4 GHz to 16 dB/cm at 18 GHz.

  19. Absorption of manganese and iron in a mouse model of hemochromatosis.

    Directory of Open Access Journals (Sweden)

    Jonghan Kim

    Full Text Available Hereditary hemochromatosis, an iron overload disease associated with excessive intestinal iron absorption, is commonly caused by loss of HFE gene function. Both iron and manganese absorption are regulated by iron status, but the relationships between the transport pathways of these metals and how they are affected by HFE-associated hemochromatosis remain poorly understood. Loss of HFE function is known to alter the intestinal expression of DMT1 (divalent metal transporter-1 and Fpn (ferroportin, transporters that have been implicated in absorption of both iron and manganese. Although the influence of HFE deficiency on dietary iron absorption has been characterized, potential effects on manganese metabolism have yet to be explored. To investigate the role of HFE in manganese absorption, we characterized the uptake and distribution of the metal in Hfe (-/- knockout mice after intravenous, intragastric, and intranasal administration of (54Mn. These values were compared to intravenous and intragastric administration of (59Fe. Intestinal absorption of (59Fe was increased and clearance of injected (59Fe was also increased in Hfe(-/- mice compared to controls. Hfe (-/- mice displayed greater intestinal absorption of (54Mn compared to wild-type Hfe(+/+ control mice. After intravenous injection, the distribution of (59Fe to heart and liver was greater in Hfe (-/- mice but no remarkable differences were observed for (54Mn. Although olfactory absorption of (54Mn into blood was unchanged in Hfe (-/- mice, higher levels of intranasally-instilled (54Mn were associated with Hfe(-/- brain compared to controls. These results show that manganese transport and metabolism can be modified by HFE deficiency.

  20. Determination of iron absorption and excretion by whole-body counting; Determination de l'absorption et de l'excretion du fer par la methode de comptage global humain

    Energy Technology Data Exchange (ETDEWEB)

    Hollard, D; Benabid, Y; Berard, M; Bonnin, J; Darnault, J; Millet, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Using a whole-body counter, the authors have studied {sup 59}Fe absorption and loss in 8 normal subjects and in 30 iron deficient patients. Results showed that whole-body counting provided an excellent and simple method for iron retention measurements, obviating many inaccuracies of previous technic. Normal absorption of radio iron with this procedure has ranged from 9 per cent to 20 per cent of the administered tracer in normal subjects, with a mean of 15 per cent. A significant increase in {sup 59}Fe absorption was noted in 21 iron-deficient patients in whom the retention ranged from 40 to 100 per cent. However, 3 iron-deficient patients were found to have low absorption, and their severe iron deficiency could be correlated with this defect in absorption. This method permits also the determination of the rate of iron excretion during the following months and therefore the study of the mechanism of some pathological loss. (authors) [French] L'utilisation de la methode de comptage humain global a permis aux auteurs d'etudier l'absorption et l'excretion du fer-59 chez 8 sujets temoins et 30 sujets hyposideremiques. Les resultats montrent que cette technique simple et directe offre de nombreux avantages sur les methodes employees jusqu'a maintenant pour cette determination. La valeur normale de l'absorption du fer chez les temoins est d'environ 15 pour cent de la dose ingeree. Ce chiffre est tres fortement augmente chez 21 sujets hyposideremiques, pouvant atteindre 100 pour cent de la dose ingeree. Par contre, pour 3 malades, cette absorption est si faible qu'elle suggere une carence par defaut d'absorption. Cette methode permet egalement de suivre l'excretion du fer au cours des mois qui suivent l'examen et de determiner le mecanisme de fuites anormales. (auteurs)

  1. Steady state simulation of a double-effect steam absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, M.S.A.M.S.; Gilani, S.I.U.H. [Universiti Teknologi Petronas, Tronoh, Perak (Malaysia). Dept. of Mechanical Engineering

    2011-07-01

    Absorption cooling systems have become increasingly popular in recent years from the viewpoint of energy and environment. Despite a lower coefficient of performance (COP) as compared to the vapor compression, absorption refrigeration systems are attractive for using inexpensive waste heat, solar, geothermal or biomass energy sources for which the cost of supply is negligible in many cases. In addition absorption refrigeration uses natural substances which do not contribute towards ozone depletion and global warming. Owing to the serious environmental problems and the price of the traditional energy resources, the use of industrial waste heat or renewable energy as the driving force for vapor absorption cooling systems is continuously increasing. A steady-state model is developed to predict the performance of an absorption refrigeration system using LiBr-water as working pair. Each component of the cycle is modelled based on mass and energy balances. The design point parameters are determined. The refrigeration effect, coefficient of performance and load factor are analyzed for different heat input. Simulation is carried out and the results are compared with actual data and showed good agreement.

  2. Light absorption of organic aerosol from pyrolysis of corn stalk

    Science.gov (United States)

    Li, Xinghua; Chen, Yanju; Bond, Tami C.

    2016-11-01

    Organic aerosol (OA) can absorb solar radiation in the low-visible and ultra-violet wavelengths thereby modifying radiative forcing. Agricultural waste burning emits a large quantity of organic carbon in many developing countries. In this work, we improved the extraction and analysis method developed by Chen and Bond, and extended the spectral range of OC absorption. We examined light absorbing properties of primary OA from pyrolysis of corn stalk, which is a major type of agricultural wastes. Light absorption of bulk liquid extracts of OA was measured using a UV-vis recording spectrophotometer. OA can be extracted by methanol at 95%, close to full extent, and shows polar character. Light absorption of organic aerosol has strong spectral dependence (Absorption Ångström exponent = 7.7) and is not negligible at ultra-violet and low-visible regions. Higher pyrolysis temperature produced OA with higher absorption. Imaginary refractive index of organic aerosol (kOA) is 0.041 at 400 nm wavelength and 0.005 at 550 nm wavelength, respectively.

  3. Absorption of DTPA from the respiratory tracts of Beagle dogs

    International Nuclear Information System (INIS)

    Dudley, R.E.; Muggenburg, B.A.; Cuddihy, R.G.

    1978-01-01

    Absorption of diethylenetriaminepentaacetic acid (DTPA) from the nasopharyngeal (NP), tracheobronchial (TB) and pulmonary (P) regions of Beagle dogs was determined because of the current interest in aerosolized DTPA as a method for removal of internally deposited radionuclides. Radiolabeled DTPA was instilled into the NP, TB and P regions of Beagle dogs and its subsequent translocation was followed for 48 hours. Results revealed that 16, 48 and 90% of the instilled DTPA was absorbed into the circulatory system from the NP, TB and P regions, respectively. A comparison was also made between NP absorption of aerosolized DTPA and DTPA instilled into the nasopharynx. Nasopharyngeal absorption of aerosolized DTPA, 23%, was slightly higher than that of instilled DTPA. Diethylenetriaminepentaacetic acid deposited in the respiratory tract remained in the body longer than intravenously injected DTPA. These findings indicate that substantial absorption of DTPA occurs from all regions of the respiratory tract and that DTPA need not be deposited deep within the respiratory tract to produce systemic absorption of DTPA for the removal of internally deposited radioactive isotopes

  4. Evaluation of mass absorption in LiBr flat-fan sheets

    International Nuclear Information System (INIS)

    Palacios, E.; Izquierdo, M.; Marcos, J.D.; Lizarte, R.

    2009-01-01

    Experiments were conducted to determine the absorption rates of refrigerant vapour in an aqueous lithium bromide flat-fan sheet for use in absorption air-conditioning systems. The solution flow rates tested ranged from 0.023 to 0.054 kg/s (84-194 kg/h), with pressure losses in the injection nozzle of from 40 to 250 kPa. The effect of the mass flow rate on both solution residence time and the sheet deformation rate was also analyzed in absorption chambers of a pre-defined length, along with the effect of the sub-cooling temperature on the amount of vapour absorbed. The downstream evolution of approach to equilibrium factor F was quantified. The mass transfer coefficient values were found to be over 3 x 10 -4 m/s. In absorption chambers 100 mm long, over 0.8 g/s l of vapour were absorbed per chamber absorption volume. Moreover, about 600 g of vapour were absorbed per kJ of solution flow work. Flat-fan sheet configurations were found to perform better than falling film and spray absorbers.

  5. [Extracting THz absorption coefficient spectrum based on accurate determination of sample thickness].

    Science.gov (United States)

    Li, Zhi; Zhang, Zhao-hui; Zhao, Xiao-yan; Su, Hai-xia; Yan, Fang

    2012-04-01

    Extracting absorption spectrum in THz band is one of the important aspects in THz applications. Sample's absorption coefficient has a complex nonlinear relationship with its thickness. However, as it is not convenient to measure the thickness directly, absorption spectrum is usually determined incorrectly. Based on the method proposed by Duvillaret which was used to precisely determine the thickness of LiNbO3, the approach to measuring the absorption coefficient spectra of glutamine and histidine in frequency range from 0.3 to 2.6 THz(1 THz = 10(12) Hz) was improved in this paper. In order to validate the correctness of this absorption spectrum, we designed a series of experiments to compare the linearity of absorption coefficient belonging to one kind amino acid in different concentrations. The results indicate that as agreed by Lambert-Beer's Law, absorption coefficient spectrum of amino acid from the improved algorithm performs better linearity with its concentration than that from the common algorithm, which can be the basis of quantitative analysis in further researches.

  6. Absorption lineshape of FA centers in alkali halides

    International Nuclear Information System (INIS)

    Baldacchini, G.; Giovenale, E.; De Matteis, F.; Scacco, A.; Somma, F.; Grassano, U.M.

    1988-01-01

    The line shape of the absorption bands of F A centers in alkali halides have been studied for the first time. The new method used for this investigation is based on the determination of the overlap between the F A1 and F A2 bands from luminescence measurements. The experimental results have been compared with calculated values deduced from the theoretical F A bands of different shapes. For both F A (I) centers in KCl:Na + and F A (II) centers in KCl:Li + and RbCl:Li + the absorption lineshape at low temperature is much closer to a sum of two Lorentzian curves than that of two Gaussian or Poissonian bands. This results shows an unexpected difference with the F centers, whose absorption lineshape is known to be Poissonian at the same temperatures

  7. Frequency and Thermal Behavior of Acoustic Absorption in ɛ-GaSe Crystals

    Science.gov (United States)

    Dzhafarova, S. Z.

    2018-04-01

    The paper presents results of measuring acoustic absorption in ɛ-GaSe crystals. The absorption of a longitudinal wave which propagates normal to the crystal layers, quadratically depends on frequency. However, it does not depend on temperature, i.e. it displays an Akhiezer behavior although its absolute value considerably exceeds the expected. The analysis of the frequency and thermal behavior of absorption of piezoelectric waves propagating along the layers, includes the deduction of contribution made by the interaction between waves and charge carriers. This analysis shows the linear dependence between the lattice absorption of these waves and the frequency. The linear frequency and weak temperature dependences of the acoustic absorption characterize the additional ultra-Akhiezer absorption in glasses. In our case, it can be caused by various polytypes forming in GaSe crystals which differ merely in a mutual arrangement of layers.

  8. Photoacoustic absorption spectra of atmospheric gases near 7603 cm-1

    International Nuclear Information System (INIS)

    Lawton, S.A.; Bragg, S.L.

    1984-01-01

    Absorption spectra of carbon monoxide, water vapor, memane, and ammonia are presented as part of an effort to determine absolute absorption cross sections for some atmospheric gases at the iodine laser wavelength

  9. Structure and dynamics in liquid water from x-ray absorption spectroscopy

    International Nuclear Information System (INIS)

    Wernet, Philippe

    2009-01-01

    Oxygen K-edge x-ray absorption spectra of water are discussed. The spectra of gas-phase water, liquid water and ice illustrate the sensitivity of oxygen K-edge x-ray absorption spectroscopy to hydrogen bonding in water. Transmission mode spectra of amorphous and crystalline ice are compared to x-ray Raman spectra of ice. The good agreement consolidates the experimental spectrum of crystalline ice and represents an incentive for theoretical calculations of the oxygen K-edge absorption spectrum of crystalline ice. Time-resolved infrared-pump and x-ray absorption probe results are finally discussed in the light of this structural interpretation.

  10. Rapidly reconfigurable slow-light system based on off-resonant Raman absorption

    International Nuclear Information System (INIS)

    Vudyasetu, Praveen K.; Howell, John C.; Camacho, Ryan M.

    2010-01-01

    We present a slow-light system based on dual Raman absorption resonances in warm rubidium vapor. Each Raman absorption resonance is produced by a control beam in an off-resonant Λ system. This system combines all optical control of the Raman absorption and the low-dispersion broadening properties of the double Lorentzian absorption slow light. The bandwidth, group delay, and central frequency of the slow-light system can all be tuned dynamically by changing the properties of the control beam. We demonstrate multiple pulse delays with low distortion and show that such a system has fast switching dynamics and thus fast reconfiguration rates.

  11. Observing broad-absorption line quasars with Spectrum-Rontgen-Gamma

    DEFF Research Database (Denmark)

    Singh, K.P.; Schnopper, H.W.; Westergaard, Niels Jørgen Stenfeldt

    1998-01-01

    Broad-absorption line quasars are found to have extremely weak soft X-ray emission when compared with other optically selected quasars. In the only example of PHL 5200 for which a detailed X-ray spectrum has been obtained with ASCA, strong absorption in the source appears to be responsible...

  12. Infrared absorption spectroscopic study of Nd substituted Zn–Mg ...

    Indian Academy of Sciences (India)

    Unknown

    20, 0⋅40, 0⋅60, 0⋅80 and 1⋅00; y = 0⋅00, 0⋅05 and 0⋅10) ferrites were prepared by standard ceramic method and characterized by X-ray diffraction, scanning electron microscopy and infrared absorption spectroscopy. Far infrared absorption.

  13. Absorption and long term retention of Mn-54 in man

    International Nuclear Information System (INIS)

    Cederblad, A.; Eriksson, R.; Alpsten, M.; Davidsson, L.

    1989-01-01

    The manganese absorption is found to be ≤ 16% after administration of some infant diets as well as from water solutions of manganese. These absorption figures might in some cases be an underestimation of the true initial absorption due to the rapid initial excretion of Mn-54. This means that both the often quoted figure for manganese absorption in humans, 3.0±0.5% and the value 10% used by ICRP 1979 are underestimations of the fractional absorption of manganese under some circumstances. The long term retention curve obtained, where the ratio between retention day 200 and day 30 had a mean value of 0.19 (range 0.10-0.35), could be compared to the two-component exponential function used by ICRP 1979 based on studies by Mahoney and Small 1968 where the corresponding ratio is 0.045. In the study by Mahoney and Small Mn-54 retention was studied after intravenous administration. We have earlier observed a difference between the metabolic handling of Mn-54 introduced orally and intravenously in man. Another model proposed by Caughtrey and Thorne 1983 consisting of a three component exponential function is in better agreement with our measurements and gives the ratio 0.22. The ICRP model for dose calculations tends to underestimate fractional absorption as well as long term retention of manganese. (orig./HP)

  14. Effect of zinc supplements on the intestinal absorption of calcium

    International Nuclear Information System (INIS)

    Spencer, H.; Rubio, N.; Kramer, L.; Norris, C.; Osis, D.

    1987-01-01

    Pharmacologic doses of zinc are widely used as zinc supplements. As calcium and zinc may compete for common absorption sites, a study was carried out on the effect of a pharmacologic dose of zinc on the intestinal absorption of calcium in adult males. The analyzed dietary zinc intake in the control studies was normal, averaging 14.6 mg/day. During the high zinc study, 140 mg zinc as the sulfate was added daily for time periods ranging from 17 to 71 days. The studies were carried out during both a low calcium intake averaging 230 mg/day and during a normal calcium intake of 800 mg/day. Calcium absorption studies were carried out during the normal and high zinc intake by using an oral tracer dose of Ca-47 and determining plasma levels and urinary and fecal excretions of Ca-47. The study has shown that, during zinc supplementation, the intestinal absorption of calcium was significantly lower during a low calcium intake than in the control study, 39.3% vs 61% respectively, p less than 0.001. However, during a normal calcium intake of 800 mg/day, the high zinc intake had no significant effect on the intestinal absorption of calcium. These studies have shown that the high zinc intake decreased the intestinal absorption of calcium during a low calcium intake but not during a normal calcium intake

  15. Absorption of high-frequency electromagnetic energy in a high-temperature plasma

    Energy Technology Data Exchange (ETDEWEB)

    Sagdeyev, R S; Shafranov, V D

    1958-07-01

    In this paper an analysis of the cyclotron and Cherenkov mechanisms is given. These are two fundamental mechanisms for noncollisional absorption of electromagnetic radiation by plasma in a magnetic field. The expressions for the dielectric permeability tensor, for plasma with a nonisotropic temperature distribution in a magnetic field, are obtained by integrating the kinetic equation with Lagrangian particle co-ordinates in a form suitable to allow a comprehensive physical interpretation of the absorption mechanisms. The oscillations of a plasma column stabilized by a longitudinal field have been analyzed. For uniform plasma, the frequency spectrum has been obtained together with the direction of electromagnetic wave propagation when both the cyclotron and Cherenkov absorption mechanisms take place. The influence of nonlinear effects on the electromagnetic wave absorption and the part which cyclotron and Cherenkov absorption play in plasma heating have also been investigated.

  16. Does the oral zinc tolerance test measure zinc absorption

    Energy Technology Data Exchange (ETDEWEB)

    Valberg, L.S.; Flanagan, P.R.; Brennan, J.; Chamberlain, M.J.

    1985-01-01

    Increases in plasma zinc concentration were compared with radiozinc absorption after oral test doses. Ten healthy, fasting subjects were each given 385 mumol zinc chloride (25 mg Zn) labelled with 0.5 muCi /sup 65/ZnCl/sub 2/ and a non-absorbed marker, /sup 51/CrCl/sub 3/, dissolved in 100 ml of water; another 10 persons were given 354 mumol zinc chloride and 125 g of minced turkey containing 31 mumol zinc also labelled with /sup 65/Zn and /sup 51/Cr. Measurements were made of plasma zinc concentration at hourly intervals for 5 hours, radiozinc absorption by stool counting of unabsorbed radioactivity 12-36 hours later, and radiozinc retention by whole body counting at 7 days. The mean percentage of radiozinc absorbed and retained in the body from the two test meals was found to be identical (42%). In contrast the increased area under the plasma zinc curve up to 5 hours after the turkey meal, 28 +/- 9 mumol/L (mean +/- SD) was significantly less than that for zinc chloride alone, 47 +/- 15 mumol/L, p less than 0.005. Despite this difference, a good correlation was found between the area under the plasma zinc curve and /sup 65/Zn absorption in individual subjects after each meal. The discrepancy between the results of zinc absorption derived from the plasma zinc curve and /sup 65/Zn absorption for the liquid and solid test meals was most likely explained by binding of zinc to food and delayed gastric emptying of the solid meal. With a test meal of turkey meat at least this dampened the plasma appearance of zinc but did not affect its overall absorption.

  17. Does the oral zinc tolerance test measure zinc absorption

    International Nuclear Information System (INIS)

    Valberg, L.S.; Flanagan, P.R.; Brennan, J.; Chamberlain, M.J.

    1985-01-01

    Increases in plasma zinc concentration were compared with radiozinc absorption after oral test doses. Ten healthy, fasting subjects were each given 385 mumol zinc chloride (25 mg Zn) labelled with 0.5 muCi 65 ZnCl 2 and a non-absorbed marker, 51 CrCl 3 , dissolved in 100 ml of water; another 10 persons were given 354 mumol zinc chloride and 125 g of minced turkey containing 31 mumol zinc also labelled with 65 Zn and 51 Cr. Measurements were made of plasma zinc concentration at hourly intervals for 5 hours, radiozinc absorption by stool counting of unabsorbed radioactivity 12-36 hours later, and radiozinc retention by whole body counting at 7 days. The mean percentage of radiozinc absorbed and retained in the body from the two test meals was found to be identical (42%). In contrast the increased area under the plasma zinc curve up to 5 hours after the turkey meal, 28 +/- 9 mumol/L (mean +/- SD) was significantly less than that for zinc chloride alone, 47 +/- 15 mumol/L, p less than 0.005. Despite this difference, a good correlation was found between the area under the plasma zinc curve and 65 Zn absorption in individual subjects after each meal. The discrepancy between the results of zinc absorption derived from the plasma zinc curve and 65 Zn absorption for the liquid and solid test meals was most likely explained by binding of zinc to food and delayed gastric emptying of the solid meal. With a test meal of turkey meat at least this dampened the plasma appearance of zinc but did not affect its overall absorption

  18. Modelling absorption and photoluminescence of TPD

    International Nuclear Information System (INIS)

    Vragovic, Igor; Calzado, Eva M.; Diaz Garcia, Maria A.; Himcinschi, C.; Gisslen, L.; Scholz, R.

    2008-01-01

    We analyse the optical spectra of N,N ' -diphenyl-N,N ' -bis(3-methyl-phenyl)-(1,1 ' -biphenyl)-4,4 ' -diamine (TPD) doped polystyrene films. The aim of the present paper is to give a microscopic interpretation of the significant Stokes shift between absorption and photoluminescence, which makes this material suitable for stimulated emission. The optimized geometric structures and energies of a neutral TPD monomer in ground and excited states are obtained by ab initio calculations using Hartree-Fock and density functional theory. The results indicate that the second distinct peak observed in absorption may arise either from a group of higher electronic transitions of the monomer or from the lowest optical transitions of a TPD dimer

  19. Two models for absorption by coloured dissolved organic matter (CDOM

    Directory of Open Access Journals (Sweden)

    Jill N. Schwarz

    2002-06-01

    Full Text Available The standard exponential model for CDOM absorption has been applied to data from diverse waters. Absorption at 440 nm (ag440 ranged between close to zero and 10 m-1, and the slope of the semilogarithmic absorption spectrum over a minimum range of 400 to 440 nm (s440 ranged between < 0.01 and 0.04 nm-1. No relationship was found between ag440 or s440 and salinity. Except in the southern Baltic, s440 was found to have a broad distribution (0.0165 ± 0.0035, suggesting that it should be introduced as an additional variable in bio-optical models when ag440 is large. An alternative model for CDOM absorption was applied to available high quality UV-visible absorption spectra from the Wisla river (Poland. This model assumes that the CDOM absorption spectrum comprises distinct Gaussian absorption bands in the UV, similar to those of benzene. Five bands were fit to the data. The mean central energy of all bands was higher in early summer (E~7.2, 6.6, 6.4, 6.2 and 5.5 eV or 172, 188, 194, 200 and 226 nm than in winter. The higher energy bands were found to decay in both height and width with increasing salinity, while lower energy bands broadened with increasing salinity. s440 was found to be correlated with shape parameters of the bands centred at 6.4 and 5.5 eV. While the exponential model is convenient for optical modelling and remote sensing applications, these results suggest that the Gaussian model offers a deeper understanding of chemical interactions affecting CDOM molecular structure.

  20. Pion absorption in flight on 3He

    International Nuclear Information System (INIS)

    Ljungfelt, S.H.

    1985-02-01

    Pion absorption in flight on 3 He has been measured in a kinematically complete manner. The experiment was done in the πE1-channel at the Swiss Institute for Nuclear Research, SIN, using π + - and π - -beams of 120 and 165 MeV kinetic energy. Two of the emitted particles were measured in coincidence and identified by their time-of-flight/pulseheight relation. The obtained two-dimensional energy representation enabled a separation of the different kinematical regions and exhibited a clear enhancement in the region of quasifree absorption, QFA. (orig./WL)

  1. Optical absorption spectra of Ag-11 isomers

    DEFF Research Database (Denmark)

    Martinez, Jose Ignacio; Fernandez, E. M.

    2009-01-01

    The optical absorption spectra of the three most; stable structural isomers of the Ag-11 cluster were calculated using the time-dependent, density functional theory within the Casida formalism. The slightly different, spectra, of the isomers may permit the identification of the ground-stale confi......The optical absorption spectra of the three most; stable structural isomers of the Ag-11 cluster were calculated using the time-dependent, density functional theory within the Casida formalism. The slightly different, spectra, of the isomers may permit the identification of the ground...

  2. Absorption of pentacaine from ulcerous rat stomach

    International Nuclear Information System (INIS)

    Tomcikova, O.; Babulova, A.; Durisova, M.; Trnovec, T.; Benes, L.

    1985-01-01

    Pentacaine is a local anaesthetic which exhibited positive effects on healing of model ulcers in the rat stomach. The in situ disappearance of pentacaine from the ulcerous and intact rat stomach was studied. Gastric ulcers were produced by oral administration of phenylbutazone (200 mg/kg) 3.5 h before absorption experiment. Pentacaine exhibited a biexponential decrease from the lumen of the stomach, the rate of which was essentially the same in both groups. The total amount of pentacaine absorbed was small because of extremly low absorption rate. (author)

  3. X-ray absorption spectra and emission spectra of plasmas

    International Nuclear Information System (INIS)

    Peng Yonglun; Yang Li; Wang Minsheng; Li Jiaming

    2002-01-01

    The author reports a theoretical method to calculate the resolved absorption spectra and emission spectra (optically thin) of hot dense plasmas. Due to its fully relativistic treatment incorporated with the quantum defect theory, it calculates the absorption spectra and emission spectra for single element or multi-element plasmas with little computational efforts. The calculated absorption spectra of LTE gold plasmas agree well with the experimental ones. It also calculates the optical thin emission spectra of LTE gold plasmas, which is helpful to diagnose the plasmas of relevant ICF plasmas. It can also provide the relevant parameters such as population density of various ionic stages, precise radiative properties for ICF studies

  4. Axially symmetric reconstruction of plasma emission and absorption coefficients

    International Nuclear Information System (INIS)

    Yang Lixin; Jia Hui; Yang Jiankun; Li Xiujian; Chen Shaorong; Liu Xishun

    2013-01-01

    A layered structure imaging model is developed in order to reconstruct emission coefficients and absorption coefficients simultaneously, in laser fusion core plasma diagnostics. A novel axially symmetric reconstruction method that utilizes the LM (Levenberg-Marquardt) nonlinear least squares minimization algorithm is proposed based on the layered structure. Numerical simulation results demonstrate that the proposed method is sufficiently accurate to reconstruct emission coefficients and absorption coefficients, and when the standard deviation of noise is 0.01, the errors of emission coefficients and absorption coefficients are 0.17, 0.22, respectively. Furthermore, this method could perform much better on reconstruction effect compared with traditional inverse Abel transform algorithms. (authors)

  5. On-demand single-photon state generation via nonlinear absorption

    International Nuclear Information System (INIS)

    Hong Tao; Jack, Michael W.; Yamashita, Makoto

    2004-01-01

    We propose a method for producing on-demand single-photon states based on collision-induced exchanges of photons and unbalanced linear absorption between two single-mode light fields. These two effects result in an effective nonlinear absorption of photons in one of the modes, which can lead to single-photon states. A quantum nonlinear attenuator based on such a mechanism can absorb photons in a normal input light pulse and terminate the absorption at a single-photon state. Because the output light pulses containing single photons preserve the properties of the input pulses, we expect this method to be a means for building a highly controllable single-photon source

  6. An Inverse Modeling Approach to Estimating Phytoplankton Pigment Concentrations from Phytoplankton Absorption Spectra

    Science.gov (United States)

    Moisan, John R.; Moisan, Tiffany A. H.; Linkswiler, Matthew A.

    2011-01-01

    Phytoplankton absorption spectra and High-Performance Liquid Chromatography (HPLC) pigment observations from the Eastern U.S. and global observations from NASA's SeaBASS archive are used in a linear inverse calculation to extract pigment-specific absorption spectra. Using these pigment-specific absorption spectra to reconstruct the phytoplankton absorption spectra results in high correlations at all visible wavelengths (r(sup 2) from 0.83 to 0.98), and linear regressions (slopes ranging from 0.8 to 1.1). Higher correlations (r(sup 2) from 0.75 to 1.00) are obtained in the visible portion of the spectra when the total phytoplankton absorption spectra are unpackaged by multiplying the entire spectra by a factor that sets the total absorption at 675 nm to that expected from absorption spectra reconstruction using measured pigment concentrations and laboratory-derived pigment-specific absorption spectra. The derived pigment-specific absorption spectra were further used with the total phytoplankton absorption spectra in a second linear inverse calculation to estimate the various phytoplankton HPLC pigments. A comparison between the estimated and measured pigment concentrations for the 18 pigment fields showed good correlations (r(sup 2) greater than 0.5) for 7 pigments and very good correlations (r(sup 2) greater than 0.7) for chlorophyll a and fucoxanthin. Higher correlations result when the analysis is carried out at more local geographic scales. The ability to estimate phytoplankton pigments using pigment-specific absorption spectra is critical for using hyperspectral inverse models to retrieve phytoplankton pigment concentrations and other Inherent Optical Properties (IOPs) from passive remote sensing observations.

  7. Absorption of 249Bk from the gastrointestinal tract

    International Nuclear Information System (INIS)

    Zalikin, G.A.; Nisimov, P.G.

    1988-01-01

    In experimets with albino mongrel female rats a study was made of the absorption of 249 Bk from the gastrointestinal tract after a single per os administration. The bulk of 249 Bk (96 per cent) administered either intravenously or per os was mainly deposited in the skeleton and liver. The value of 249 Bk absorption from the gastrointestinal trat by days 4 and 8 following administration was 0.05 per cent

  8. F K-edge soft X-ray absorption spectroscopy

    International Nuclear Information System (INIS)

    Sugimura, Tetsuro; Kawai, Jun; Maeda, Kuniko; Fukushima, Akiko; Shin, S.; Motoyama, Muneyuki; Nakajima Tsuyoshi

    2001-01-01

    We measured F X-ray absorption spectra of various fluorine compounds using a synchrotron radiation at KEK-PF. The absorption spectra were measured using X-ray fluorescence yield (XFY) and total electron yield (TEY) methods. Change of the spectral shape has a relation to the metal-fluorine bond distance. By comparing with the experimental spectrum and calculated spectrum, F 2p state density is divined into up and down states. (author)

  9. Multiple scattering approach to X-ray absorption spectroscopy

    International Nuclear Information System (INIS)

    Benfatto, M.; Wu Ziyu

    2003-01-01

    In this paper authors present the state of the art of the theoretical background needed for analyzing X-ray absorption spectra in the whole energy range. The multiple-scattering (MS) theory is presented in detail with some applications on real systems. Authors also describe recent progress in performing geometrical fitting of the XANES (X-ray absorption near-edge structure) energy region and beyond using a full multiple-scattering approach

  10. The Effect of Phonon Relaxation Process on Absorption Spectra ...

    African Journals Online (AJOL)

    In this work we study the effect of phonon relaxation process on the absorption spectra using the Green's function technique. The Green's function technique which is widely used in many particle problems is used to solve the Kubo formula which describes the optical absorption process. Finally the configurational diagram is ...

  11. Effect of applied mechanical stress on absorption coefficient of compounds

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Manoj Kumar, E-mail: mkgupta.sliet@gmail.com [Department of Applied Sciences, Bhai Gurdas Institute of Engineering and Technology, Sangrur (India); Singh, Gurinderjeet; Dhaliwal, A. S.; Kahlon, K. S. [Department of Physics, Sant Longowal Institute of Engineering & Technology Deemed University, Longowal (Sangrur) India-148106 (India)

    2015-08-28

    The absorption coefficient of given materials is the parameter required for the basic information. The measurement of absorption coefficient of compounds Al{sub 2}O{sub 3}, CaCO{sub 3}, ZnO{sub 2}, SmO{sub 2} and PbO has been taken at different incident photon energies 26, 59.54, 112, 1173, 1332keV. The studies involve the measurements of absorption coefficient of the self supporting samples prepared under different mechanical stress. This mechanical stress is render in terms of pressure up to 0-6 ton by using hydraulic press. Measurements shows that absorption coefficient of a material is directly proportional to applied mechanical stress on it up to some extent then become independent. Experimentally measured results are in fairly good agreement with in theoretical values obtained from WinXCOM.

  12. Vacuum ultraviolet (VUV) absorption spectra of chromatin and its components

    International Nuclear Information System (INIS)

    Dodonova, N.Y.; Kiseleva, M.N.; Petrov, M.Y.; Tsyganenko, N.M.; Bubyakina, V.V.; Chikhirzhina, G.I.

    1984-01-01

    The electron absorption spectra of thin films of chromatin and chromatin components in the ultraviolet region (140-280 nm) were investigated. The absorption coefficients μ(lambda) of chromatin, nucleosomes with and without histone H1, total histones (TH), and DNA were compared. The spectra of nucleosomes differ from the sum-spectrum of DNA plus TH. The chromatin and nucleosome spectra are not similar in the spectral region of 190-160 nm. The lack of additivity of absorption coefficients at different wavelengths may be explained by different conformational changes of DNA, TH in nucleosomes and chromatin during the process of drying aqueous solutions for the preparation of thin films. The μ(lambda) values are useful for an estimate of the DNA and TH absorption in chromatin and nucleosomes in discussing UV and VUV irradiation damages. (Auth.)

  13. Relative absorption and dermal loading of chemical substances: Consequences for risk assessment

    NARCIS (Netherlands)

    Buist, H.E.; Schaafsma, G.; Sandt, J.J.M. van de

    2009-01-01

    Quantification of skin absorption is an essential step in reducing the uncertainty of dermal risk assessment. Data from literature indicate that the relative dermal absorption of substances is dependent on dermal loading. Therefore, an internal exposure calculated with absorption data determined at

  14. Absorption of CO2 in Biogas with Amine Solution for Biomethane Enrichment

    Directory of Open Access Journals (Sweden)

    Wassana Kamopas

    2016-05-01

    Full Text Available Biogas upgrading with carbon dioxide absorption in a column of monoethanolamine (MEA solution was carried out. The effects of controlled parameters on the CO2 absorption such as gas flow rate, solution concentration, height to diameter ratio of the column were considered. High CH4 concentration could be achieved at low gas flow rate and high MEA concentration. The CH4 concentration could be up from 70-75% to 92-95% by volume for 0.2 M MEA. A set of breakthrough curves was obtained to determine the absorption characteristics, such as the absorption constant (k, the absorption time when the CO2 concentration at the outlet was 50% of the concentration at the inlet (t, and the absorption period (t* when the CH4 concentration was over 90%. An empirical equation of the methane enrichment with the related parameters was developed.

  15. One-nucleon absorption of slow pions by atomic nuclei and π condensation

    International Nuclear Information System (INIS)

    Troitskij, M.A.; Koldaev, M.V.; Chekunaev, N.I.

    1977-01-01

    Solved is a problem of one-nucleon absorption of slow pions by real nuclei. Without ion condensate one-nucleon absorption forbiddenness decreases due to nucleus finiteness, as nucleus finiteness results in nucleon momentum nonconservation. As a result one-nucleon absorption probability differs from a zero and equals the order of 10 -3 . Calculated is one-nucleon absorption probability in nuclear matter as well as in atomic nuclei due to π condensate existence. The condensate part is shown to be considerable in a finite system as well. For heavy nuclei the condensate presence results in this probability increase about 100 times. Experiments on one-nucleon absorption of slow pions may be critical to elucidate a question of π condensate presence in nuclear systems. In conclusion experimental data available on pion absorption are discussed and it is paid attention to the necessity of carrying out further experiments

  16. Absorption of water and lubricating oils into porous nylon

    Science.gov (United States)

    Bertrand, P. A.

    1995-01-01

    Oil and water absorption from air into sintered porous nylon can be described by infiltration into the pores of the material. This process can be modeled by a diffusion-like mechanism. For water absorption, we find a formal diffusion coefficient of 1.5 x 10(exp -4)sq cm/min when the nylon is initially dry. The diffusion coefficient is 4 x 10(exp -6)sq cm/min when the nylon is oil-impregnated prior to air exposure. In a 52% RH atmosphere, dry nylon absorbs 3% w/w water, and oil-impregnated nylon absorbs 0.6% w/w water. For oil absorption there are three steps: (1) surface absorption and infiltration into (2) larger and (3) smaller pores. Surface absorption is too fast to be measured in these experiments. The diffusion coefficient for the second step is 6 x 10(exp -4)sq cm/min for SRG-60 oil into dry nylon and 4 x 10(exp -4)sq cm/min for air-equilibrated nylon. The diffusion coefficient for the third step is about 1 x 10(exp -6)sq cm/min for both cases. The total amount of oil absorbed is 31% w/w. The interaction between water and nylon is not as strong as that between water and cotton-phenolic: oil can replace water, and only a small amount of water can enter previously oil-impregnated nylon.

  17. Tests of intestinal absorption using carbon-14-labeled isotopes

    International Nuclear Information System (INIS)

    Fromm, H.; Sarva, R.P.

    1983-01-01

    Beta radiation-emitting isotopes are being used increasingly in diagnostic gastroenterology for the study of absorption. The major reason for the popularity of radioisotopes is that their use is convenient for patient and physician alike. They often obviate naso- or orointestinal intubation and the collection, storage, and analysis of stool. The radioactivity used for the studies of digestive and absorptive processes is small and is not hazardous. In spite of the safety of the radiolabeled compounds, their use is restricted in children and pregnant women. Therefore, for most tests, promising alternative methods that make use of the stable isotope of carbon, /sup 13/C, instead of the radioactive /sup 14/C have been developed. The analysis of stable isotopes requires more sophisticated technology than that of radioactive compounds, however. Only a few centers presently are equipped and staffed to analyze stable isotopes on a routine basis. In contrast, the analysis of radioactive isotopes has become a routine procedure in almost ever major laboratory. The last decade has brought the development of several radioactive absorption tests. The clinically most useful tests relate to the study of bile acid, fat, lactose, and xylose absorption. All of these tests utilize the excretion rate of /sup 14/CO/sub 2/ in breath after ingestion of a /sup 14/C-labeled compound as a measure of the rate of its absorption or malabsorption

  18. Drug gastrointestinal absorption in rat: Strain and gender differences.

    Science.gov (United States)

    Oltra-Noguera, Davinia; Mangas-Sanjuan, Victor; González-Álvarez, Isabel; Colon-Useche, Sarin; González-Álvarez, Marta; Bermejo, Marival

    2015-10-12

    Predictive animal models of intestinal drug absorption are essential tools in drug development to identify compounds with promising biopharmaceutical properties. In situ perfusion absorption studies are routinely used in the preclinical setting to screen drug candidates. The objective of this work is to explore the differences in magnitude and variability on intestinal absorption associated with rat strain and gender. Metoprolol and Verapamil absorption rate coefficients were determined using the in situ closed loop perfusion model in four strains of rats and in both genders. Strains used were Sprague-Dawley, Wistar-Han, Wistar-Unilever, Long-Evans and CD∗IGS. In the case of Metoprolol only CD∗IGS and Wistar Unilever showed differences between males and females. For Verapamil, Wistar Han and Sprague-Dawley strains do not show differences between male and female rats. That means that in these strains permeability data from male and female could be combined. In male rats, which are commonly used for permeability estimation, there were differences for Metoprolol permeability between Sprague-Dawley (with lower permeability values) and the other strains, while for Verapamil Sprague-Dawley and Wistar-Han showed the lower permeability values. In conclusion, the selection of rat's strain and gender for intestinal absorption experiments is a relevant element during study design and data from different strains may not be always comparable. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Percutaneous absorption of several chemicals, some pesticides included, in the red-winged blackbird

    Science.gov (United States)

    Rogers, J.G.; Cagan, R.H.; Kare, M.R.

    1974-01-01

    Percutaneous absorption in vivo through the skin of the feet of the red-winged blackbird (Agelaius phoeniceus) has been investigated. Absorption after 18-24 hours exposure to 0.01 M solutions of salicylic acid, caffeine, urea, 2,4-D, dieldrin, diethylstilbesterol, and DDT was measured. Of these, only DDT and diethylstilbesterol were not absorbed to a measurable degree. The solvents ethanol, dimethylsulfoxide (DMSO), and vegetable oil were compared with water in their effects on the absorption ofcaffeine, urea, and salicylic acid. Ethanol, DMSO,and oil each decreased percutaneous absorption of salicylic acid. DMSO increased absorption of caffeine, and ethanol had no effect on it. Neither DMSO nor ethanol affected penetration of urea. Partition coefficients (K) (epidermis/water) were determined for all seven penetrants. Compounds with higher values of K showed lower percutaneous absorption. These findings suggest that K may be useful to predict percutaneous absorption in vivo. It appears unlikely that percutaneous absorption contributes greatly to the body burden of 2,4-D and dieldrin in A. phoeniceus.

  20. Absorption of Manganese and Iron in a Mouse Model of Hemochromatosis

    Science.gov (United States)

    Kim, Jonghan; Buckett, Peter D.; Wessling-Resnick, Marianne

    2013-01-01

    Hereditary hemochromatosis, an iron overload disease associated with excessive intestinal iron absorption, is commonly caused by loss of HFE gene function. Both iron and manganese absorption are regulated by iron status, but the relationships between the transport pathways of these metals and how they are affected by HFE-associated hemochromatosis remain poorly understood. Loss of HFE function is known to alter the intestinal expression of DMT1 (divalent metal transporter-1) and Fpn (ferroportin), transporters that have been implicated in absorption of both iron and manganese. Although the influence of HFE deficiency on dietary iron absorption has been characterized, potential effects on manganese metabolism have yet to be explored. To investigate the role of HFE in manganese absorption, we characterized the uptake and distribution of the metal in Hfe −/− knockout mice after intravenous, intragastric, and intranasal administration of 54Mn. These values were compared to intravenous and intragastric administration of 59Fe. Intestinal absorption of 59Fe was increased and clearance of injected 59Fe was also increased in Hfe−/− mice compared to controls. Hfe −/− mice displayed greater intestinal absorption of 54Mn compared to wild-type Hfe+/+ control mice. After intravenous injection, the distribution of 59Fe to heart and liver was greater in Hfe −/− mice but no remarkable differences were observed for 54Mn. Although olfactory absorption of 54Mn into blood was unchanged in Hfe −/− mice, higher levels of intranasally-instilled 54Mn were associated with Hfe−/− brain compared to controls. These results show that manganese transport and metabolism can be modified by HFE deficiency. PMID:23705020

  1. Midinfrared absorption measured at a lambda/400 resolution with an atomic force microscope.

    Science.gov (United States)

    Houel, Julien; Homeyer, Estelle; Sauvage, Sébastien; Boucaud, Philippe; Dazzi, Alexandre; Prazeres, Rui; Ortéga, Jean-Michel

    2009-06-22

    Midinfrared absorption can be locally measured using a detection combining an atomic force microscope and a pulsed excitation. This is illustrated for the midinfrared bulk GaAs phonon absorption and for the midinfrared absorption of thin SiO(2) microdisks. We show that the signal given by the cantilever oscillation amplitude of the atomic force microscope follows the spectral dependence of the bulk material absorption. The absorption spatial resolution achieved with microdisks is around 50 nanometer for an optical excitation around 22 micrometer wavelength.

  2. Foliar absorption and translocation of 137cs in egyptian olive plants

    International Nuclear Information System (INIS)

    Ramadan, A.A.; Maly, A.I.

    1999-01-01

    Foliar absorption and translocation of 137Cs by olive leaves were studied. Olive seedlings were transferred to the greenhouse in pots containing fine Nile silt.. Two seriies of pot experiments were conducted at the Nuclear Research Center site at Inshas. The treatments were conducted on leaves at the two middle nodes of the selected shoots. The lower surface of the olive leaf absorbed more 137Cs at the studied pH values as compared with the upper surface. The results show that changing the pH from 2 to 3 had no have any effect on the foliar absorption of 137Cs. Further increase of pH value caused the 137Cs foliar absorption to show a minimum at pH 5 then a maximum at pH 7. At pH 8 the foliar absorption of 137Cs started to decrease again. The concentration of translocated 137Cs was found to decrease gradually in the leaves above and below the treated ones. Absorption of 137Cs increased with time in the first 24 hours followed by lower absorption rates till the end of the experiment after 148 hours

  3. Absorption and enhancement corrections using XRF analysis of some chemical samples

    International Nuclear Information System (INIS)

    Falih, Arwa Gaddal

    1996-06-01

    In this work samples containing Cr, Fe and Ni salts invarying ratios were prepared so as to represent approximately the concentrations of these elements in naturally occurring ore samples. These samples were then analyzed by EDXRF spectrometer system and the inter element effects (absorption and enhancement) were evaluated by means of two method: by using AXIL-QXAS software to calculate the effects and by the emission-transmission method to experimentally determine the same effects. The results obtained were compared and a discrepancy in the absorption results was observed. The discrepancy was attributed to the fact that the absorption in the two methods was calculated in different manners, i.e. in the emission-transmission method the absorption factor was calculated by adding different absorption terms by what is known as the additive law, but in the software program it was calculated from the scattered peaks method which does not obey this law. It was concluded that the program should be modified by inserting the emission-transmission method in the software program to calculate the absorption. Quality assurance of the data was performed though the analysis of the standard alloys obtained from the International Atomic Energy Agency (IAEA). (Author)

  4. Near-infrared light absorption by brown carbon in the ambient atmosphere

    Science.gov (United States)

    Chung, C.; Hoffer, A.; Beres, N. D.; Moosmüller, H.; Liu, C.; Green, M.; Kim, S. W.; Engelbrecht, J. P.; Gelencser, A.

    2017-12-01

    Organic aerosols have been assumed to have little-to-no absorption in the red and near-infrared spectral regions of solar radiation, even though a class of organic aerosols were shown to absorb significantly in these spectral regions. Here, we show that ambient atmospheric data from commonly-used 7-wavelength aethalometers contain evidence of abundant near-infrared light absorption by organic aerosol. This evidence comes from the absorption Ångström exponent over 880 950 nm, which often exceeds values explainable by fresh or coated black carbon, or mineral dust. This evidence is not due to an artifact from the instrument random errors or biases, either. The best explanation for these large 880/950 nm absorption Ångström exponent values in the aethalometer data is near-infrared light absorption by tar balls. Tar balls are among common particles from forest fire.

  5. The absorption budget of fresh biomass burning aerosol from realistic laboratory fires

    Science.gov (United States)

    Wagner, N. L.; Adler, G. A.; Franchin, A.; Lamb, K.; Manfred, K.; Middlebrook, A. M.; Selimovic, V.; Schwarz, J. P.; Washenfelder, R. A.; Womack, C.; Yokelson, R. J.

    2017-12-01

    Wildfires are expected to increase globally due to climate change. The smoke from these wildfires has a highly uncertain radiative effect, largely due to the lack of detailed understanding of its optical properties. As part of the NOAA FIREX project, we have measured the optical properties of smoke primarily from laboratory burning of North American fuels at the Missoula Fire Sciences Laboratory. Here, we present a budget of the aerosol absorption from a portion of the laboratory fires. The total aerosol absorption was measured with photoacoustic spectrometers (PAS) at four wavelengths (405 nm, 532 nm, 660 nm, 870 nm) spanning the visible spectral region. The aerosol absorption is attributed to black carbon which absorbs broadly across the visible and ultraviolet (UV) spectral region and brown carbon (BrC) which absorbs in the blue and UV spectral regions. Then aerosol absorption measurements are compared with measurements of refractory black carbon (rBC) concentration by laser induced incandescence (SP2) and measurements of BrC concentration from a particle-into-liquid sampler coupled to a liquid absorption cell (BrC-PILS). Periodically, a thermodenuder was inserted upstream of all of the instruments to constrain the relationship between aerosol volatility and absorption. We synthesize these measurements to constrain the various contributors to total absorption including effects of lensing on rBC absorption, and of BrC that is not volatilized in the thermodenuder.

  6. The effect of self-absorption in hollow cathode lamp on its temperature

    International Nuclear Information System (INIS)

    Sobhanian, S.; Naghshara, H.

    2014-01-01

    It has been shown experimentally that even a small error in the calculation of the temperature inside the hollow-cathode lamp (HCL) and the current applied to the lamp, may cause a tremendous error in determination of the absorption ratio in optical resonance absorption (ORA) method. This effect is intensified nonlinearity for large absorption ratios. If a higher current is applied to a copper hollow cathode lamp, the copper density inside the lamp is increasing rapidly. Due to the cylindrical (axisymmetric) form of the lamp, the density of atoms around the main axis of the lamp becomes greater than that near the internal wall. In this case the auto-absorption (or self-absorption) is occurred and as its result, the emission spectrum produced by copper atoms is locally absorbed before going out from the lamp. This absorption is stronger near the main axis compared with the areas near the wall because of the Gaussian profile of the spectral line. Two different Cu atoms ground state lines with the similar lower state (327.4 nm and 324.7 nm) are used in this work as optical resonance absorption and the absorption coefficient is obtained for three different pressures (0.6, 4.5 and 14 µbar). The best values for copper HCL temperature and for maximum HCL current were found respectively 450 K, and 5mA. (author)

  7. The absorption of thermal radiation by water films

    International Nuclear Information System (INIS)

    Pearson, K.G.; Elliott, D.

    1977-04-01

    Except at the shortest wavelengths (i.e. <2μm) liquid water is relatively opaque to thermal radiation. It is also a poor reflector, reflecting back only about 2% of normal incident radiation. It is shown that when radiation falls on a plane water surface from a parallel heated surface about 93.5% of the incident radiation enters the surface, the remaining 6.5% being reflected back to the source. It is also shown that, for source temperatures up to the maximum of interest in reactor safety studies, a large fraction of the thermal radiation which enters the water is absorbed on passing through a distance approaching 0.5 mm. Since liquid water films of such thickness can be expected to exist on the pressure tubes of an SGHWR following a loss of coolant accident it follows that, irrespective of the condition of the pressure tube wall, the absorptivity of the pressure tubes will in effect be about 0.9. Data are presented for experiments performed to determine the absorptivity of water films on a polished surface whose dry absorptivity was measured to be 0.18. The presence of the water film, of estimated thickness 0.3 mm, increased the absorptivity of the surface to a value close to unity. (author)

  8. Cholesterol Absorption and Synthesis in Vegetarians and Omnivores.

    Science.gov (United States)

    Lütjohann, Dieter; Meyer, Sven; von Bergmann, Klaus; Stellaard, Frans

    2018-03-01

    Vegetarian diets are considered health-promoting; however, a plasma cholesterol lowering effect is not always observed. We investigate the link between vegetarian-diet-induced alterations in cholesterol metabolism. We study male and female omnivores, lacto-ovo vegetarians, lacto vegetarians, and vegans. Cholesterol intake, absorption, and fecal sterol excretion are measured as well as plasma concentrations of cholesterol and noncholesterol sterols. These serve as markers for cholesterol absorption, synthesis, and catabolism. The biliary cholesterol secretion rate is estimated. Flux data are related to body weight. Individual vegetarian diet groups are statistically compared to the omnivore group. Lacto vegetarians absorb 44% less dietary cholesterol, synthesized 22% more cholesterol, and show no differences in plasma total and LDL cholesterol. Vegan subjects absorb 90% less dietary cholesterol, synthesized 35% more cholesterol, and have a similar plasma total cholesterol, but a 13% lower plasma LDL cholesterol. No diet-related differences in biliary cholesterol secretion and absorption are observed. Total cholesterol absorption is lower only in vegans. Total cholesterol input is similar under all vegetarian diets. Unaltered biliary cholesterol secretion and higher cholesterol synthesis blunt the lowered dietary cholesterol intake in vegetarians. LDL cholesterol is significantly lower only in vegans. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Near-perfect broadband absorption from hyperbolic metamaterial nanoparticles

    Science.gov (United States)

    Riley, Conor T.; Smalley, Joseph S. T.; Brodie, Jeffrey R. J.; Fainman, Yeshaiahu; Sirbuly, Donald J.; Liu, Zhaowei

    2017-02-01

    Broadband absorbers are essential components of many light detection, energy harvesting, and camouflage schemes. Current designs are either bulky or use planar films that cause problems in cracking and delamination during flexing or heating. In addition, transferring planar materials to flexible, thin, or low-cost substrates poses a significant challenge. On the other hand, particle-based materials are highly flexible and can be transferred and assembled onto a more desirable substrate but have not shown high performance as an absorber in a standalone system. Here, we introduce a class of particle absorbers called transferable hyperbolic metamaterial particles (THMMP) that display selective, omnidirectional, tunable, broadband absorption when closely packed. This is demonstrated with vertically aligned hyperbolic nanotube (HNT) arrays composed of alternating layers of aluminum-doped zinc oxide and zinc oxide. The broadband absorption measures >87% from 1,200 nm to over 2,200 nm with a maximum absorption of 98.1% at 1,550 nm and remains large for high angles. Furthermore, we show the advantages of particle-based absorbers by transferring the HNTs to a polymer substrate that shows excellent mechanical flexibility and visible transparency while maintaining near-perfect absorption in the telecommunications region. In addition, other material systems and geometries are proposed for a wider range of applications.

  10. Effects of Omeprazole on Iron Absorption: Preliminary Study

    Directory of Open Access Journals (Sweden)

    Mahmut Yaşar Çeliker

    2013-09-01

    Full Text Available Objective: Increasing numbers of pediatric and adult patients are being treated with proton pump inhibitors (PPIs. PPIs are known to inhibit gastric acid secretion. Nonheme iron requires gastric acid for conversion to the ferrous form for absorption. Ninety percent of dietary and 100% of oral iron therapy is in the nonheme form. To the best of our knowledge, the effect of PPIs on iron absorption has not been studied in humans. Our study assessed the relationship between omeprazole therapy and iron absorption in healthy subjects. Materials and Methods: We recruited 9 healthy volunteers between June 2010 and March 2011. Subjects with chronic illness, anemia, or use of PPI therapy were excluded. Serum iron concentrations were measured 1, 2, and 3 h after the ingestion of iron (control group. The measurements were repeated on a subsequent visit after 4 daily oral administrations of omeprazole at a dose of 40 mg (treatment group. Results: One female and 8 male volunteers were enrolled in the study with a mean age of 33 years. There was no statistical difference detected between baseline, 1-h, 2-h, and 3-h iron levels between control and treatment groups. Conclusion: Administration of omeprazole for a short duration does not affect absorption of orally administered iron in healthy individuals.

  11. Broadening microwave absorption via a multi-domain structure

    Directory of Open Access Journals (Sweden)

    Zhengwang Liu

    2017-04-01

    Full Text Available Materials with a high saturation magnetization have gained increasing attention in the field of microwave absorption; therefore, the magnetization value depends on the magnetic configuration inside them. However, the broad-band absorption in the range of microwave frequency (2-18 GHz is a great challenge. Herein, the three-dimensional (3D Fe/C hollow microspheres are constructed by iron nanocrystals permeating inside carbon matrix with a saturation magnetization of 340 emu/g, which is 1.55 times as that of bulk Fe, unexpectedly. Electron tomography, electron holography, and Lorentz transmission electron microscopy imaging provide the powerful testimony about Fe/C interpenetration and multi-domain state constructed by vortex and stripe domains. Benefiting from the unique chemical and magnetic microstructures, the microwave minimum absorption is as strong as −55 dB and the bandwidth (<−10 dB spans 12.5 GHz ranging from 5.5 to 18 GHz. Morphology and distribution of magnetic nano-domains can be facilely regulated by a controllable reduction sintering under H2/Ar gas and an optimized temperature over 450–850 °C. The findings might shed new light on the synthesis strategies of the materials with the broad-band frequency and understanding the association between multi-domain coupling and microwave absorption performance.

  12. [The percutaneous absorption of diclofenac].

    Science.gov (United States)

    Riess, W; Schmid, K; Botta, L; Kobayashi, K; Moppert, J; Schneider, W; Sioufi, A; Strusberg, A; Tomasi, M

    1986-07-01

    The percutaneous absorption of diclofenac diethylammonium 1.16% (w/w) in a combination of emulsion cream and gel (Voltaren Emulgel) and of diclofenac sodium 1% (w/w) in a cream formulation (Voltaren cream) was investigated in guinea-pig, rabbit and man. The percutaneous absorption of diclofenac sodium in guinea-pig was 3 to 6% of the dose when the cream formulation in doses of 320, 100 or 40 mg was applied on 10 cm2 of occluded skin and left in place for 6 h. The transdermal delivery of 14C-labelled diclofenac yielded plateau plasma concentrations of radiotracer from 1.5 h after application until removal of the residual cream. Subsequently the steady state drug depots in the skin and muscle tissue were depleted promptly. During daily administration the steady state levels in the muscle tissue in proximity to the application site were about 3 times higher than in distant muscle tissue. By topical application on knee joints of rabbits diclofenac penetrated into the patellar ligament, the adipose corpus and the synovial fluid. In man the percutaneous absorption was 6% of the dose when the Emulgel formulation was spread by 5 mg/cm2 and left for 12 h on non-occluded skin. The pattern of metabolites of diclofenac in human urine was the same after topical and oral administration. In man, upon daily topical administration of 3 times 2.5 g cream formulation (10 mg/cm2) the diclofenac steady state plasma levels were 20 to 40 nmol/l.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Atmospheric pressure and temperature profiling using near IR differential absorption lidar

    Science.gov (United States)

    Korb, C. L.; Schwemmer, G. K.; Dombrowski, M.; Weng, C. Y.

    1983-01-01

    The present investigation is concerned with differential absorption lidar techniques for remotely measuring the atmospheric temperature and pressure profile, surface pressure, and cloud top pressure-height. The procedure used in determining the pressure is based on the conduction of high-resolution measurements of absorption in the wings of lines in the oxygen A band. Absorption with respect to these areas is highly pressure sensitive in connection with the mechanism of collisional line broadening. The method of temperature measurement utilizes a determination of the absorption at the center of a selected line in the oxygen A band which originates from a quantum state with high ground state energy.

  14. Intestinal absorption of calcium and magnesium in rats

    International Nuclear Information System (INIS)

    Erhart, J.

    1981-01-01

    Absorption of Ca and Mg was studied in isolated and perfused jejunum segments of rats using radioactive 45 Ca and 28 Mg. At ion concentrations of 1.5 and 10 mmol in the bath solution, the influence of uraemia, 1,25-(OH) 2 D 3 and the complementary ion was investigated. Absorption of Ca ++ was found to be slightly reduced by uraemia and renormalized by 1,25-(OH) 2 D 3 substitution. Transport of Ca ++ was significantly increased in the presence of Mg ++ , both in healthy rats and in animals with chronic uraemia. Mg ++ absorption, in contrast, was significantly reduced in rats with uraemia, and 1,25-(OH) 2 D 3 substitution was found to reduce it even further. In the presence of Ca ++ , transport of Mg ++ was lowered both in healthy rats and in rats with chronic uraemia. (MG) [de

  15. Two-Photon Absorption in Organometallic Bromide Perovskites

    KAUST Repository

    Walters, Grant

    2015-07-21

    Organometallic trihalide perovskites are solution processed semiconductors that have made great strides in third generation thin film light harvesting and light emitting optoelectronic devices. Recently it has been demonstrated that large, high purity single crystals of these perovskites can be synthesized from the solution phase. These crystals’ large dimensions, clean bandgap, and solid-state order, have provided us with a suitable medium to observe and quantify two-photon absorption in perovskites. When CH3NH3PbBr3 single crystals are pumped with intense 800 nm light, we observe band-to-band photoluminescence at 572 nm, indicative of two-photon absorption. We report the nonlinear absorption coefficient of CH3NH3PbBr3 perovskites to be 8.6 cm GW-1 at 800 nm, comparable to epitaxial single crystal semiconductors of similar bandgap. We have leveraged this nonlinear process to electrically autocorrelate a 100 fs pulsed laser using a two-photon perovskite photodetector. This work demonstrates the viability of organometallic trihalide perovskites as a convenient and low-cost nonlinear absorber for applications in ultrafast photonics.

  16. Two-Photon Absorption in Organometallic Bromide Perovskites

    KAUST Repository

    Walters, Grant; Sutherland, Brandon R; Hoogland, Sjoerd; Shi, Dong; Comin, Riccardo; Sellan, Daniel P.; Bakr, Osman; Sargent, Edward H.

    2015-01-01

    Organometallic trihalide perovskites are solution processed semiconductors that have made great strides in third generation thin film light harvesting and light emitting optoelectronic devices. Recently it has been demonstrated that large, high purity single crystals of these perovskites can be synthesized from the solution phase. These crystals’ large dimensions, clean bandgap, and solid-state order, have provided us with a suitable medium to observe and quantify two-photon absorption in perovskites. When CH3NH3PbBr3 single crystals are pumped with intense 800 nm light, we observe band-to-band photoluminescence at 572 nm, indicative of two-photon absorption. We report the nonlinear absorption coefficient of CH3NH3PbBr3 perovskites to be 8.6 cm GW-1 at 800 nm, comparable to epitaxial single crystal semiconductors of similar bandgap. We have leveraged this nonlinear process to electrically autocorrelate a 100 fs pulsed laser using a two-photon perovskite photodetector. This work demonstrates the viability of organometallic trihalide perovskites as a convenient and low-cost nonlinear absorber for applications in ultrafast photonics.

  17. Modelling the light absorption coefficients of oceanic waters: Implications for underwater optical applications

    Science.gov (United States)

    Prabhakaran, Sai Shri; Sahu, Sanjay Kumar; Dev, Pravin Jeba; Shanmugam, Palanisamy

    2018-05-01

    Spectral absorption coefficients of particulate (algal and non-algal components) and dissolved substances are modelled and combined with the pure seawater component to determine the total light absorption coefficients of seawater in the Bay of Bengal. Two parameters namely chlorophyll-a (Chl) concentration and turbidity were measured using commercially available instruments with high sampling rates. For modelling the light absorption coefficients of oceanic waters, the measured data are classified into two broad groups - algal dominant and non-algal particle (NAP) dominant. With these criteria the individual absorption coefficients of phytoplankton and NAP were established based on their concentrations using an iterative method. To account for the spectral dependence of absorption by phytoplankton, the wavelength-dependent coefficients were introduced into the model. The CDOM absorption was determined by subtracting the individual absorption coefficients of phytoplankton and NAP from the measured total absorption data and then related to the Chl concentration. Validity of the model is assessed based on independent in-situ data from certain discrete locations in the Bay of Bengal. The total absorption coefficients estimated using the new model by considering the contributions of algal, non-algal and CDOM have good agreement with the measured total absorption data with the error range of 6.9 to 28.3%. Results obtained by the present model are important for predicting the propagation of the radiant energy within the ocean and interpreting remote sensing observation data.

  18. Influence of iron on plutonium absorption by the adult and neonatal rat

    International Nuclear Information System (INIS)

    Sullivan, M.F.; Ruemmler, P.S.; Buschbom, R.L.

    1986-01-01

    To determine how iron affects plutonium absorption, adult rats were gavaged with 238 Pu nitrate (pH 2) after they had been fed an iron-deficient diet or treated with iron supplements. Neonatal rats born to dams on an iron-deficient diet were also gavaged with 238 Pu. An iron-deficient diet resulted in enhanced 238 Pu absorption both in the adults and in neonates born to iron-deficient dams. Ferric iron increased 238 Pu absorption 12-fold in adult rats; injected iron-dextran reduced that increase; gavaged ferrous iron reduced 238 Pu absorption to one-third of the control value. Rat neonates absorbed 30 to 40 times as much 238 Pu as adults; absorption was lowered in groups that received iron supplements: Iron-dextran caused a 50% reduction; ferric iron, 95%; and ferrous iron, greater than 95%. The results demonstrate an effect of the oxidation state of iron on plutonium absorption in adult rats different from that observed in suckling rats. The results suggest that the high rate of 238 Pu absorption by neonatal animals is due not only to the permeability of their intestines but also to their high demand for iron

  19. Absorption mechanism of three curcumin constituents through in situ intestinal perfusion method

    Directory of Open Access Journals (Sweden)

    Y.-H. Wang

    2017-09-01

    Full Text Available This study aimed to investigate the absorption mechanism of three curcumin constituents in rat small intestines. Self-emulsification was used to solubilize the three curcumin constituents, and the rat in situ intestinal perfusion method was used to study factors on drug absorption, including drug mass concentration, absorption site, and the different types and concentrations of absorption inhibitors. Within the scope of experimental concentrations, three curcumin constituents were absorbed in rat small intestines through the active transport mechanism.

  20. Energy absorption capabilities of composite sandwich panels under blast loads

    Science.gov (United States)

    Sankar Ray, Tirtha

    As blast threats on military and civilian structures continue to be a significant concern, there remains a need for improved design strategies to increase blast resistance capabilities. The approach to blast resistance proposed here is focused on dissipating the high levels of pressure induced during a blast through maximizing the potential for energy absorption of composite sandwich panels, which are a competitive structural member type due to the inherent energy absorption capabilities of fiber reinforced polymer (FRP) composites. Furthermore, the middle core in the sandwich panels can be designed as a sacrificial layer allowing for a significant amount of deformation or progressive failure to maximize the potential for energy absorption. The research here is aimed at the optimization of composite sandwich panels for blast mitigation via energy absorption mechanisms. The energy absorption mechanisms considered include absorbed strain energy due to inelastic deformation as well as energy dissipation through progressive failure of the core of the sandwich panels. The methods employed in the research consist of a combination of experimentally-validated finite element analysis (FEA) and the derivation and use of a simplified analytical model. The key components of the scope of work then includes: establishment of quantified energy absorption criteria, validation of the selected FE modeling techniques, development of the simplified analytical model, investigation of influential core architectures and geometric parameters, and investigation of influential material properties. For the parameters that are identified as being most-influential, recommended values for these parameters are suggested in conceptual terms that are conducive to designing composite sandwich panels for various blast threats. Based on reviewing the energy response characteristic of the panel under blast loading, a non-dimensional parameter AET/ ET (absorbed energy, AET, normalized by total energy